HomeMy WebLinkAbout45695-Z �o��S�fF�tX Town of Southold 6/9/2022
o -
P.O.Box 1179
r 53095 Main Rd
yea �ao� Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 43134 Date: 6/9/2022
THIS CERTIFIES that the building IN GROUND POOL
Location of Property: 560 Horton Ave,Mattituck
SCTM#: 473889 Sec/Block/Lot: 141.-2-6
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
1/5/2021 pursuant to which Building Permit No. 45695 dated 1/20/2021
was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
accessory in-ground swimming pool fenced to code as applied for.
The certificate is issued to O'Neill,Sean
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 45695 5/6/2022
PLUMBERS CERTIFICATION DATED
6
or' a Signature
S��focK� TOWN OF SOUTHOLD
BUILDING DEPARTMENT
H x TOWN CLERK'S OFFICE
o • SOUTHOLD,, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 45695 Date: 1/20/2021
Permission is hereby granted to:
O'Neill, Sean :.
1508 Main Rd:
Jamesport, NY 11947
To: construct an in-ground swimming pool as applied for.
At premises located at:
560 Horton Ave, Mattituck
SCTM # 473889
Sec/Block/Lot#-141:-2-6
Pursuant to application dated 1/5/2021 and approved by the Building Inspector.
To expire on 7/22/2022.
Fees:
SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $250.00
CO- SWIMMING POOL $50.00
Total: $300.00
Iding Inspector,
Form No.6
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
TOWN HALL
765-1802
APPLICATION FOR CERTIFICATE OF OCCUPANCY
This application must be filled in by typewriter or ink and submitted to the Building Department with the following:
A. For new building or new use:
1. Final survey of property with accurate location of all buildings, property lines,streets, and unusual natural or
topographic features.
2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form).
3. Approval of electrical installation from Board of Fire Underwriters.
4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead.
5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate
of Code Compliance from architect or engineer responsible for the building.
6. Submit Planning Board Approval of completed site pian requirements.
B. For existing buildings(prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses:
1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic
features.
2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is
denied,the Building Inspector shall state the reasons therefor in writing to the applicant.
C. Fees
1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00,
Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00.
2. Certificate of Occupancy on Pre-existing Building- $100.00
3. Copy of Certificate of Occupancy- $.25
4. Updated Certificate of Occupancy- $50.00
5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00
Date.
—T
New Construction:-x-/76 -5 .ui�4 Old or Pre-existing Building: (check one)
Pvv�
Location of Properly: Ate7y y AAz M�77i7ue�
House No. Street Hamlet
Owner or Owners of Property: _:! wzw ✓ U iVt/LL
Suffolk County Tax Map No 1000, Section Block Lot
/
Subdivision "/6-1, S Filed Map. Lot:
Permit No. Date of Pen-nit. Applicant:
Health Dept. Approval: Underwriters Approval:
Planning Board Approval:
Request for: TemporarrCertificate Final Certificate: (check one)
Fee Submitted: $
Applicant S1211acurt
Buildin6 Department Application
AUTHORIZATION
(Where the Applicant is not the Owner)
residing at_J`� Z 2z.
T
(Print property owner's name) (Mailing Address)
do hereby authorize _J- c' _XX--S L
(Agent)
to apply on my behalf to the.
Southold Building Department_
' X07
Owner's Signature)
Gv D�
(Print O,;rner's Name)
pF SOUryo!
0
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 �Q sean.devlin -town.southold.ny.us
Southold,NY 11971-0959
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Sean O'Neill
Address: 560 Horton Ave city.Mattituck st: NY zip: 11952
Building Permit#: 45695 section: 141 Block: 2 Lot: 5
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Home Owner License No:
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Service
Commerical Outdoor X 1st Floor Pool X
New X Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks 1
Disconnect Switches 1 4'LED Exit Fixtures Pump
Other Equipment: Pump 220GFI , Salt Generator, 1 Light 120GFI
Notes: Pool
Inspector Signature: Date: May 6, 2022
p 9
S.Devlin-Cert Electrical Compliance Form
�o,*pF SOUIyo�
# # TOWN .OF SOUTHOLD'BUILDING DEPT.
�ycou765-1802
r
IN'SPECTIO
N
[ ] FOUNDATION.IST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [` ]: INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ° ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
V4ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O
REMARKS:
DATE �� Z� INSPECTOR
Of SOUIy� _ - --- ---
-( 5 No f-4-on Avo
TOWN OF SOUTHOLD BUILDING DEPT. .
765-1802
INSPECTION
[ j FOUNDATION 1ST [ ] ROUGH PL13G.
`[ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING
[ ] FRAMING/STRAPPING [ ] FINAL
[ ]
-FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O
REMARKS: �`��
t DATE. S INSPECTOR _� '
Zapf SOpI�,�
f # TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1 ST [ ] ROUGH PL13G.
[ ] FOUNDATION 2ND { rFINAL
ULATION/CAULKING
FRAMING/STRAPPING [ 1"Vb I
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] -ELECTRICAL (FINAL)
[ ] CODE VIOLATION- [ ] PRE C/O
REMARKS: owl -
-
�l�ri�,S a
DATE INSPECTOR
SOUlyolo
f # TOWN OF SOUTHOLD BUILDING DEPT.
"Tow, 631-765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PL13G.
[ ] FOUNDATION 2ND [ ] NSULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL Pip
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS:
k,OL/
OVA 4
DATE INSPECTOR
FIELD IN5PECTiON REFORT DATE t4O 1�T�
Fou"ATa N(1ST
FOI NDATION(2ND)
.. C�oi
y
' ROUGHSFRAMING& . ` ,, ',�.'- �•.,• . ,. •• • .� � :
. ;6
PLUM- ING y
TNSC'T1,ATIOLIPEA N..Y.
STATE ENERGY CODE.
10
::FILIAL' tz
v( : .IJ
15-1'a oil
z
RIS
is,
' - 10
1
TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST
BUILDING DEPARTMENT Do you have or need the following,before applying?
TOWN HALL Board of Health
SOUTHOLD, NY 11971 4 sets of Building Plans
TEL: (631) 765-1802, Planning Board approval
FAX: (631) 765-9502 (� C� Survey_ y/
Southoldtownny.gov PERMIT NO. U _` Check V/
Septic Form
N.Y,S.D.E.C.
Trustees
C.O.Application V/
Flood Permit
Examined 120 Single&Separate
Truss Identification Form
Storm-Water Assessment Form_
s Zq Contact:
Approved 120 Mail to:
Disapproved a/c
-Frh—o 631- yg'y yzys—
Expiration _ _.,r • ;,'20:
17
Bui n ector
JAN - 6 202
APPLICATION FOR BUILDING PERMIT
Date ,�/ 20�
- INSTRUCTIONS ��� —�
a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4
sets of plans, accurate plot plan to scale. Fee according to schedule.
b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or
areas, and waterways.
c. The work covered by this application may not be commenced before issuance of Building Permit.
d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit
shall be kept on the premises available for inspection throughout the work.
e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector
issues a Certificate of Occupancy.
f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of
issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the
property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an
addition six months. Thereafter, a new permit shall be required.
APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the
Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or
Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The
applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit
authorized inspectors on premises and in building for necessary inspections.
e/w/7m( lPmJLS L,7-P
(Signature of applicant or name, if a corporation)
20 30x 2,, 1_1U7'C_dc)641 C- , A13'//93
(Mailing address of applicant)
State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder
Pj-)A)71,7 AC>vZ
Name of owner of premises
(As on the tax roll or latest deed)
If applicant i a corporation, ign r f duly authorized officer
e and tide—of corporate officer)
Builders License No. 1911,7/,1
Plumbers License No.
Electricians License No.
Other Trade's License No.
1. Location of land on which proposed work will be done: r,
'rte IJ AJV�Z>vAy 14VZC
House Number Sireet Hamlet
County Tax Map No. 1000 Section /`// ,Blocky,�,;,�2.;,: ;;:"t:_, •;{,�� Lot Zell
Y'.�,tf:.J''• .,."a,• _its....;=r�,',.,. .'„l
Subdivision Filed Map No. Lot
2. State existing use and occupancy of premises and intended use and occupancy of proposed construction:
a. Existing use and occupancy /4 ST �C_2✓�iy�
b. Intended use and occupancy/.,P- 5;.-
3.
>3. Nature of work(check which applicable): New Building Addition Alteration
Repair Removal Demolitioner W k ?'//
(Description)
4. Estimated Cost Fee
(To be paid on filing this application)
5. If dwelling, number of dwelling units Number of dwelling units on each floor
If garage, number of cars
6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.
7. Dimensions of existing structures, if any: Front �9: 5' Rear a.,579, 5- Depth a?s,
Height 45 Number of Stories
Dimensions of same structure with alterations or additions: Front Rear
Depth Height Number of Stories
8. Dimensions of entire new construction: Front Rear Depth -
Height Number of Stories
9. Size of lot: Front 99: 93 Rear 9>9..3 Depth
10. Date of Purchase Name of Former Owner
11. Zone or use district in which premises are situated �Si�t��i/�L
12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO_X
13. Will lot be re-graded? YES )' NO Will excess fill be removed from premises?YES -K NO
14.Names of Owner ofpremisesSf/�i� oAddressslo 1�losz7wv eve Phone No.631-,:?3<;--22 Y3
Name of Architect Address '`'g""`"`� Phone No
Name of Contractor C/417ug PduLs i_-ri->. Address7,o-'3ux 9,GLvG+z,,,ePhone No. 631-
15
3/15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO
* IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED.
b. Is this property within 300 feet of a tidal wetland? * YES NO___X
* IF YES,D.E.C. PERMITS MAY BE REQUIRED.
16. Provide survey, to scale, with accurate foundation plan and distances to property lines.
17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey.
18. Are there any covenants and restrictions with respect to this property? * YES NO A"
* IF YES, PROVIDE A COPY.
STATE OF NEW YORK)
SS:
COUNTY O&F Lk )
being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)He is the ZZ)A)7i2Z'4!fZ �
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;
that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be
performed in the manner set forth in the application filed therewith.
'!orn to efore me this
(p day of 20 a
Notary Public MARY DIANA FOS gnature of Applicant
\ Notary Public,State of New York
No.52-4655242
Cualified in Suffolk County
Commission Expires Aug.31,20.0�1
So&�y�l
h Q
Town Hall Annex It J�L Telephone(631)--76.5:1 80
54375 Main Road
Faz�(63 1).765 g5Q2-;
P.O.Box 1179 • ro-er.richertdid-wn.souttto'Id�ny.us
Southold,NY 11971-0959
Q
-wait-1 y -= A p R 2 9 2021
BUILDING DEPARTMENT
TOWN OF SOUTHOLD -
APPLICATION FOR ELECTRICAL INSPECTION
REQUESTED BY: Date:�/ - 12, 2
Company Name:
Name:
License No.:
Address:
,Phone No.:
JOBSITE INFORMATION: (Indicates. required information)
*Name:
*Address:
*Cross Street: �?�i7LL:yrZ�
*Phone No.:
Permit No.:
Tax Map District: 1000 Section: Block: Lot:
*BRIEF DESCRIPTION OF WORK (Please Print Clearly)
(Please Circle All That Apply)
*Is.job ready for inspection: YES/ NO Rough'In' Final
*Do you need a Temp Certificate"' / NO
Temp-information (If needed} -
*Service Size: 1 Phase 3Phase 100 150 200 300' 350 -400 Other
*New Service: Re-connect Underground Number of Meters Change of Service Overhead
Additional Information: PAYMENT DUE WITH APPLICATION
82-Request for Inspection Form ,�� �
PERMIT# Address:
Switches
Outlets
GFI's I
Surface
Sconces
H H's
UC Lts
Fans Fridge
HW
Exhaust Oven
Dryer
Smokes DW
Service
Carbon Micro
Generator
Combo Cooktop
Transfer
AC
AH
Mini
Special:
Comments 11
-G,
��
Scott A. Russell
.���°Sum STc0)) ��J[WA`7C')E]EZ
SUPERVISOR co MANAGEMENT
SOUMOLD TOWN HALL-IJ'-O_Box 1179 b
Main Rosa_SOUTHOLD NEW YORK 11971 Town of Southold
CHAPTER 236 - STORM ATER MANAGEMEN'I"PP Q1ZK SHEET
(TO BE COMPLETED.BY THE APPLICANT)
^DOE S F--jLHE--Fozr ING:--_ -: -_—
Yes Wo iC .CK.AM THAT AM"
j][✓ .A- Clearing, grubbing, grading-or stripping of land which aff-ects more
Eq
/ than 5,000 square feetof� ground surface.
i J Eq B. Excavation or-filling involving more than 200 cubic yards of material
within any raw tigu%s area-
El c �
L�
C.
Site preparation.on slopes which exceed 10 feet vertical rise to
100.feet of.horizontal distance::
D[D/D_'Site preparation within 100 feet of wetlands, beach, bluff or coastal
erosion hazard area-
E_
rea_E_ Site preparation within the one-hundred-year floodplain as depicted
.on-.FIRM Map of any watercourse_:
s i
Q F. Installation of neve or'resurfaced impervious surfaces of 1,000 square
feet or more, unless.prior:'approval of a Stormwater Management
Control Plan was received by the Town and the proposal includes
in=kindreplacement of impervious surfaces.
Fangdna
nswered NO to all of the questions above, STOP' Complete the Applicant section below with your Name,
re, Contad information,Date & County Tax Map'Number! Chapter 236 does not apply to your project_
nswered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan
mpleted Check list Form to the Building Departs= mnlhyouur Binding Permit Application.
APPueArrr tPm - s:GT.M. 1000 Date
perry Owner,Design Professional,Agcn;Contractor,Ordeal -
• District
NAME A A i 7-uK ouL_s LTA --LL
Section Block Lot
FOR BUILDING'DEPAf?T;VIENT USL OCL-;""
- c«uoct h,torrnarwtc l0 3f- 73Y:7GG 5'
• Ttl�pr ly.eEn- .
Reviewed By.
Date
Property Address/Location of Construction Work= — — — — — — — — — — — — _ — — —
n Approved for processing Building Permit-
-��(Z_f}�21 YU/CJ ^AVE LJ Stormwater Management Control Plan Not Required.
/V! / S1orMWu-1er Managernen:Co-trot Ptae
LJ (Forward to Engineering Department for Review.)
FORM SMCP-TOS MAY 2014
f I
S.C.T.M. NO. DISTRICT: 1000 SECTION: 141 BLOCK: 2 LOT(S):6
b
tz
T®�
4 VE,VU
U.P.
410.79'
PIPE EpG
N
z 730 E OF PAVEMENT
J s 5O"
tTjz
OO }
p9O ¢ Q
d: .93° U.P.
O a, >_
N o
COVERED U.P.
° z COVERED STOOP PIPE
Of
STOOP GUY
Cn
N: :DliFRM :: Y '::::= L4
cn p #560: �'' Fri -P
,- o �- 26.1 p :N ��'x 3z' O
Zm LU
o OWE O w
g p z M w c9
0 2.9' z wo-�
_ o =
12.8': g
VI L 3Z' O
; :' _SH G• 2�'
N ••
�¢ w '3, x7.0' U
z O
1O
1.2'E O
s, O
SI-0c, D£ Cpplvc 41 01.40 L A7 36,
0.5'74 '1'��`�
0.1'W 3.2'N
S
A 24" OAK oA" p
SO'' � 4' S�OCKAD
e GATE
2.0'N
1.7'E
LAND F/F 99.93 A \ J w
¢ zw�
RICHARD CORAZZINI JR. o
o wg
13 z Qz
� >
THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL
LOCATIONS SHOWN ARE FROM FIELD OBSERVATIONS
AREA: 11 ,409.17 S.F. o r 0.26 ACRES AND OR DATA OBTAINED FROM OTHERS.
ELEVATION DATUM:
UNAUTHORIZED ALTERATION OR ADD177ON TO THIS SURVEY IS A WOLA77ON OF SEC77ON 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY
MAP NOT BEARING THE LAND SURVEYOR'S.EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID 7RUE COPY. GUARANTEES INDICATED HEREON SHALL RUN
ONLY TO THE PERSON FOR WHOM 774E SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TU71ON
LISTED HEREON, AND TO 77•HE ASSIGNEES OF 774E LENDING 1NS777U770N, GUARAN7FES'ARE NOT TRANSFERABLE.
774E OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO 774E STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE ]HEREFORE THEY ARE
NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADD17IONAL S7RUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS
AND/OR SUBSURFACE S7RUCfURES RECORDED OR UNRECORDED ARE NOT GUARAN7FED UNLESS PHYSICALLY EVIDENT ON 7HE PREMISES AT THE 77ME OF SURVEY
SURVEY OF. DESCRIBED PROPERTY CERTIFIED TO: SEAN C. O'NOLL;
MAP OF: EQUITY SETTLEMENT SERVICES;
FILED: OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY;
SITUATED AT: MATTITUCK MEADOWBROOK MORTGAGE;
TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC
SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design
P.O. Boz 153 Aquebogue, New York 11931
FILE # 17-121 SCALE: 1"=20' DATE: AUG. 2, 2017 PHONE (831)298-1588 FAX (831) 298-1588
N.Y.S. LISC. NO. 050882 maintaining the records of Robert J. Hennessy & Kenneth M. Aoychulf
S.C.T.M. DISTRICT: 1000 SECTION: 141 BLOCK: 2 LOT(S):6
H
OR�o
� AV
U.P.
410.79'
PIPE N . EDGE OF Fq
�.�., z 73 7 S�S CEMENT
J
Z
O } `
ti
o m 99.93, U.P.
C VERED U.P.
ZCOVERED, . STOOP PIPE
m N. STOOP 2g:s• GUY
33.3cn
Cv
#5600.
:NG• :'vi: fr -P
,L o
26. 1pgljp295/a. .:.;. .;•: :
7ti,,,y O
Z O
0. O
w w
Z 0,4E
w
g 0 z rel L_Uj c�
0 2.9' z U-
o x
z 8, g w
U)
VI W SH L ��
0
140
z. O
1.2'E > O
O .
O
6' S;,0C1qO f F �
Fvc T^��
0.5'N
0.1'W 3.2.N
I S .73 ' 24" OAK 30
OA4
. I � ST�CKADE GATE
2.0'N
1.7'E w w
LAND N/F 99, w w LU J
OF •93' Y z U_
RICHARD CORAZZINI JR. J
U a. w
O Z Q Z
3:
• I �0 g >
.THE WATER SUPPLY.,WELLS, DRYWELLS AND CESSPOOL
LOCADONS SHOWN ARE FROM FIELD OBSERV4710NS
AND OR DATA OBTAINED FROM OTHERS,
AREA: 11 ,40 .17 S.F. or 0.26 ACRES EiEVAnoN DATUM:
UNAUTHORIZED LTERA77ON OR ADD177ON TO THIS SURVEY IS A WOLA77ON OF SEC77ON 7209 OF THE NEW. YORK STATE EDUCA77ON LAW. •COPIES OF. THIS SURVEY
MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN
ONLY TO THE PERSON FOR WHOM 7HE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING 1NS777U770N
LISTED'HEREON, AND TO .THE ASSIGNEES OF 77-1E LENDING INS71TU770N, GUARANTEES ARE:NOT TRANSFERABLE.
THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUC7URES ARE FOR A. SPECIFIC PURPOSE AND USE THEREFORE THEY ARE•
NOT /N7FNDED TQ MONUMENT 7HE PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES, ADD177ONAL STRUCTURES OR AND OTHER IMPROVEMEN75 EASEMENTS
AND/OR SUBSURFACE S7RUMRES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY
SURVEY on -DE CRIBED .PROPERTY CERTIFIED TO: SEAN. C. O'NEILL;
MAP OF: EQUITY.SETTLEMENT 'SERVICES; -
FILED: OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY;
SITUATED AT: M ITUCK MEADOWBROOK MORTGAGE;
TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC
SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design
`& + t� P.O. Boz 153 Aquebogue, New York 11931
FILE # 17-121 SCALE: 1"=2O� DATE: AUG. 2, 2017 PHONE. (831)298-1588 PAX (631) 298-1588
N.Y S LISC. NO 050882 maintaining the records of Robert J. Hennessy & Kenneth M. woychuk
J
APPRO ED AS NOTED
� ZI B.P.# _ DQNiPL`( WITH AIL OWN CODES
ODES Of
DATE: YQRI� STATE & ONS OF
U� BY: NFW
FEE AS REQUIRED A
NOT Y BUILDING DEP
AR T A4ENT AT M To 4 PMSOUTHOLD Ip ZBA
785-1802ANSPECTIONS FOR THE SOUTHO OWN
13
FOLLOWING
1. FOUNDATION CONCRETE OUIRED SO OLDIOWNIRUSIEES
FOR
2. ROUGH - FRAMING-& PLUIJIBING
3. INSULATION
4. FINAL - CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION
THE CODES OF NEW
REQUIREMENFOR
YORK STATE. NOT RUCT ON (ERRORS. PXgUIRE®
DESIGN OR CA'T'spEeno"
occupANIcy OR
,s UNLAWFULUSE
► e��� °e� apo
.. :• ' •: POpL'S¢(: •WilhateG.. •R. •..B•. "•C . :D; E. I F IG'. .N ..�"• :.-� .. N:. �•.
H
- ibCo 14)L114, .
.,;30 •3 4! 6 6' Q ,!4 . 6. ":4:. -4.4:.
4-A
:sp'• $4.-:Ve. '::G :.iz: .;•e.'. .:,g..::n, a . .a,;od:7'-4'.'i3�0
iDQa`:.: 1604,. 16 '.?p:.i.s° i6 b�`::r.}_;'•;ri`'•4:C =.4: 4. : g:.. 4`r0•:T-fi 'lip
ibCb? :.6- Ar: :e: c..9::. :ar_:es'4 "''•. i"Y4660
1011 . �.'-.A:�? 112600
y� 1'aYi6 . :.107!
OD
Iwo:. ..Y: low
a 7{i.
E,�� = :1•"'yak .r.. 10• 14:''i 26:'r."d 4� ;'.G s': _;ti $'- :4. :4 -
t a a: r. �i000
:7il1 ( �'s' _ ' :i :6F ° : ��° 6': :4' '4'-0°' •iL'3" '3{!D° : 6'e1R'�":'. ' ::��eli:"`• :.: ..20: .:49:, 3 4': ; ,
= :: C :::: ' ',8e6a : ;&s0' '• Y ; �3 4`$ :. :8'�±#� -� ` ::6.',3.718';• _ 4. - 20w:. :�o: xtpoo
:. .1 •.1B[42r. •:I6:- •3s.•i:.:3'i4'.: .:s-:� M. IBM
, R
=1 16 :.30 3'�a.r4'6' '.6.= 4:: :4� '1D 4'b 16500.
-8'r ." :.Yo: ;30::r- ,: r w t D.
�4
:s fir! `+� _ ;.�': L. °7' c' :; 3..: -:i :io° :2a..r�";. �,:'.r~: � :: � .s.:. r-0'_ .4• :isso6
ama.�_'
:1tSc4:`.` ~.imi49'- 4E _ 4P 4': Fr:c•s.,v3b° �-t: 21on" -
-� -'' v X.
!Maw
-low!
.'•`': .�-_'��: a, Y - - � ,- �7f.�R�:•� �9��w:-.. .. y 'PSI DI
ao
wp
T�+{`! 8° �' '�`�` 63�' :+f'"$° T..?44*;:' _ '�.� ®sed
_ �®
f9�5A•fo36f�6rl�ifli •.. ' :. + pg ap
4v L
oose®oeorw. : .. :
�,�. od
-
_ rIB�i3� cam..
c do
' ®01
F� DMNG BOARD
.arm ^ e�.LNuea7ffis7 NT$ p®. ROM.
Mumma A
® -
9esa: .
maus
4lTOP0391�.AL R.�ca . �" L PLAM
. 'i: _ J btl}l>$Ql96Pi96trt3 '• - •
TYPICAL '^- ®�" ���8®FMMF
CORNER commm fam OEM&
POOL SECTI
� •'- . . :. .. .. � � Ce=p`:: �,�_�
Complies With
I i0
I 2020 Code Section"30321`=303A Swimming Pools,Spas and Hot Tubs R�FESSiO P �
' Section•11326 of ftie'R&Writial Code of New York
=-----------='sj---------`--- Section3109 ' the BuildingCodeofNewYork'
{ Section N1103-12(11403.12)Residential Pools and Permanent Residential Spas ®®�,' ��,��������,� REV. SCALE. „ y.
Section31093.12-31097A-Pools and Spas Gates,Barriers lAMES®EERK®50'P.E.
Section G106 Entrapmerrt Profection ®A
TYPICAL P EL$nFFNER "Section G107 Alarns =
260®LES DRIVE
Section 1=4201—E4312 Electrical Connections for P0015 MATT iTUK, ®RK 119S2 ® 4 ��V �E�
NOTES:
1. DIVING BOARD TO CONFORM WITH ANSI/APSP/ICC-5 SEC 6
2. NO SOIL DISCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION
3. POOL MUST BE SURROUNDED BY A CONTINUOUS BARRIER CONSTRUCTED IAW REQ.OF SEC 326.4.2.1-R326.4.2.6 OF THE NYS RESIDENTIAL CODE(2020)AND ALL SECTIONS OF THE SOUTHOLD CODE
4. WALLS MAY SERVE AS PART OF THE POOL BARRIER AS PER SEC 326.4.2.8 AND ALL WINDOWS HAVE A SELF LATCHING DEVICE
5. ACESS GATES SHALL COMPLY WITH SEC R326.5.2 OF THE NYS RESIDENTIAL CODE(2020)AND BE SELF CLOSING,SELF LATCHING AND BE SECURELY LOCKED WHEN POOL IS NOT IN USE OR SUPERVISED. ALLL GATES ARE
TO OPEN AWAY FROM THE POOL AREA.
6. DURING CONSTRUCTION THE CONTRACTOR SHALL ERECT A TEMPORARY BARRIER AROUND THE EXCAVATION IAW CODE OF THE TOWN OF SOUTHOLD.
7. POOL MUST BE EQUIPED WITH AN APPROVED POOL ALARM CAPABLE OF DETECTING ENTRY INTO THE WATER AND SOUNDING AN AUDIBLE ALARM WHEN DETECTED THAT IS AUDIBLE AT THE POOLSIDE AND INSIDE THE
DWELLING.THE ALARM MUST BE INSTALLED,MAINTAINED AND USED IN ACCORDANCE WITH TEH MAUFACTURERS INSTRUCTIONS.THE ALARM MUST MEET ASTM F2208"STANDARD SPECIFICATION FOR POOL ALARMS".THE
DEVICE MUST OPERATE INDEPENDENT(NOT ATTACHED TO OR DEPENDENT ON)OF PERSONS.
8. POOL SUCTION FITTINGS(EXCEPT FOR SURFACE SKIIMERS)MUST BE PROVIDED WITH A COVER THAT CONFORMS TO ASME/ANSI Al 12.19.8M OR A MINIMUM 18"X23"DRAIN GRATE OR A CHANNEL DRAIN SYSTEM.POOL
CIRCULATION SYSTEM MUST BE EQUIPTED WITH ATMOSPHERIC VACUUM RELEIF.SUCH VACUUM RELIEF SYSTEMS SHALL CONFORM WITH ASME Al 12.19.17 OR BE A GRAVITY SYSTEM APPROVED BY THE TOWN OF
SOUTHOLD.POOL SALL BE PROVIDED WITH A MINIMUM OF 2 SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE.THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF V AND MUST BE PIPED SUCH THAT WATER
IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS).VACUUM/PRESSURE CLEANING FITTINGS SHALL BE IN ACCESSIBLE POSITION,MINIMUM OF 6"AND
NO GREATER THAN 12"BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BE AN ATTACHMENT TO THE SKIMMER/SKIMMERS. A REQUIRED POOL ATMOSPHERIC VACUUM RELEIF SYSTEM SHALL BE INSTALLED AS PER
NYS RESIDENTIAL CODE R326.6.3(2020)AND IN ACCORDANCE TO TOW CODE
9. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC),PRINCIPALLY ARTICLE 680 AND THE NYS RESIDENTIAL CODE SECTION 4102 THROUGH 4106.ALL ELECTRICAL DEVICES MUST BE
APPROVED BY UNDERWRITERS LABORATORIES AND BE PROTECTED BY A GOUND FAULT CURRENT INTERRUPER(GFCI).CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE PROVIDING POWER TO POOL
LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E4203.5. ALL METAL ENCLOSURES,FENCES OR RAILINGS NEAR OR ADJACENT TO THE SWIMMING POOL THAT MAY BECOME
ELECTRICALLY CHARGED DUE TO CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY GROUNDED.
10. WATER SOURCE FILLING THE POOL SHALL BE EQUIPPPED WITH A BACKFLOW PROTECTION DEVICE IAW NYS PLUMBING CODE 608.
11. ALL PIPING IS DIAGRAMMATIC UNLESS OTHERWISE STATED.
12. WALKS, IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM THE POOL EDGE.
13. A MEANS OF EGRESS FROM DEEP AND SHALLOW ENDS MUST BE PROVIDED IAW ANSI/NSPI-5 SECTION 6.
14. CONTRACTOR TO PLACE THE POOL IAW TOWN OF SOUTHOLD CODE SETBACKS.
15. ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY.
16 THE DESIGN IS BASED ON A DRAINAGE SOIL WITH<10%SILT.GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION.IF GROUND WATER EXISTS WITHIN 60"FROM GRADE,DEWATERING FACILITIES WILL BE
REQUIRED.
17 ALL GAS AND OIL WATER HEATERS(IF INSTALLED)FOR THE IN-GROUND SWIMMING POOL SHALL BE NATIONAL APPLIANCE ENERGY CONSERVATION ACT(NAECA)COMPLIANT.POOL HEATERS SHALL BE TESTED IAW ANSI
221.56 AND SHALL BE INSTALLED IAW MANUFACTURERS SPECIFICATIONS.OIL FIRED POOL HEATERS SHALL BE TESTED IAW UL726.POOL HEATERS SHALL BE LOCATED OR GUARDED TO PROTECTAGAINST ACCIDENTAL
CONTACT OF HOT SURFACES BY PERSONS.POOL HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES.A BYPASS LINE SHALL BE INSTALLED FROM THE INLET TO OUTLET TO ADJUST WATER
FLOW THROUGH THE HATER.POOL HEATERS SHALL BE PROVIDED WITH THE FOLLOWING ENERGY CONSERVATION MEASURES:
17.1 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE OPERATION OF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO
ALLOW RESTARTING WITHOUT RELIGHTING THE PILOT LIGHT. AT LEAST ONE THERMOSTAL MUST BE PROVIDED FOR EACH HEATING SYSTEM.HEATED SWIMMING POOLS SHALL BE EQUIPTED WITH A POOL COVER.(exempt
FROM THIS ARE OUTDOOR POOLD)DERIVING 20%OF THE ENERGY FOR HEATING THE POOL FROM RENEWABLE SOURCES OVER AN OPERATING SEASON.
17.2 TIME CLOCKS SHALL BE INSTALLED SO THE PUMP CAN BE SET TO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS,AND CAN BE SET TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER IN A
CLEAN AND SANITORY CONDITION IAW APPLCIABLE SANITORY CODE OF NEW YORK STATE.
18 BACKFILL WILL BE DONE WITH CLEAN EARTH FREE OF ROOTS AND DEBRIS. BACKFILL HEIGHT AND WATER LEVEL TO BE WITHIN 8"OF EACH OTHER. PLACE CONCRETE ON SANDY LOAM SOIL. CLAY TO BE REMOVED AND
REPLACED WITH SANDY LOAM.
19 THERE ARE MAIN DRAINS IN THIS POOL.THERE ARE TWO.APPROVED SUCTION OUTLETS WITH A MINIMUM OF V OF SEPARATION. THE SUCTION OUTLETS ARE PIPED SO THAT WATER IS
DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM-RELEIF-PROTECTED LINE TO THE PUMP.COMP I WITH ENTRAPMENT PROTECTION AS PER CODE.
20 THE POOL WAS DESIGNED REFERENCES AS THE FOLLOWING:
20.1 THE RESIDENTIAL BUILDING CODE OF NEW YORK STATE(2020)SEC R326 OF EW Y0
20.2 THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE(2020)SEC R403.10 ,tP y)D
nP
20.3 THE FUEL GAS CODE OF NEW YORK STATE(2020)
20.4 THE NEW YORK STATE SANITORY CODE.
20.5 ANSI/APSP/ICC-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS. ^V ''v ��+� POOL NOTES SCALE: .
M1` .
20.6 BOCA CODE SECTION 421. ®pR 07 p�' JAMES DEERKOSKI, P.E. 4`t•n
®CESS► DATE: r`102%2020r;`.::
20.7 CODE OF THE TOWN OF SOUTHOLD 260 DEER DRIVE -
='
MATTITUK, NEW YORK 11952 DR AWING:N.U.IVIBE'R
;r,