HomeMy WebLinkAbout47700-Z �oSUFFs1 Town of Southold 5/18/2022
P.O.Box 1179
o _ 53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 43082 Date: 5/18/2022
THIS CERTIFIES that the building AS BUILT ALTERATION
Location of Property: 3795 Main Bayview Rd, Southold
SCTM#: 473889 Sec/Block/Lot: 78.-2-15.2
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
3/8/2022 pursuant to which Building Permit No. 47700 dated 4/19/2022
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
"as built' second floor bedroom and bathroom to existing single-family dwelling as applied for.
The certificate is issued to PGA Capital LLC
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 47700 5/11/2022
PLUMBERS CERTIFICATION DATED
A o ized 0
nature
�o�suFE1111r4 TOWN OF SOUTHOLD
ay BUILDING DEPARTMENT
H TOWN CLERK'S OFFICE
"o • SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 47700 Date: 4/19/2022
Permission is hereby granted to:
PGA Capital LLC
175 Pinelawn Rd Ste 300
Melville, NY 11747
To: legalize "as built' second floor bedroom and bathroom to existing single-family dwelling
as applied for with flood permit. Additional certification may be required.
At premises located at:
3795 Main Bayview Rd, Southold
SCTM #473889
Sec/Block/Lot# 78.-2-15.2
Pursuant to application dated 3/8/2022 and approved by the Building Inspector.
To expire on 10/19/2023.
Fees:
AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $620.80
CO-ALTERATION TO DWELLING $50.00
Flood Permit $100.00
Total: $770.80
Building Inspector
. OF SO!/jyQl
h O
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 aQ sean.devlinl-town.southold.ny.us
Southold,NY 11971-0959
Q�yCOUffm��
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: PGA Capital LLC
Address: 3795 Main Bayview Rd city:Southold st: NY zip: 11971
Building Permit#: 47700 Section: 78 Block: 2 Lot: 15.2
Contractor: DBA: Varsity Electrical Contracting License No: 38511 ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Service
Commerical Outdoor 1st Floor Pool
New Renovation X 2nd Floor X Hot Tub
Addition Survey X Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt 10 Ceiling Fixtures Bath Exhaust Fan 1
Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors 1
Main Panel A/C Condenser Single Recpt Recessed Fixtures 10 CO2 Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan 1 Combo Smoke/CO 1
Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks
Disconnect Switches $ 4'LED Exit Fixtures Pump
Other Equipment:
Notes: " AS BUILT NO VISUAL DEFECTS " Finished Second Floor
Inspector Signature: Date:
May 11, 2022
S.Devlin-Cert Electrical Compliance Form
Paul A. Lombardo, Architect APR m 1 2022
Paul A.Lombardo, RA,A.I.A. ji
+�..>•
BU�LUi(v�: :�•.
TOWN OF SOLO r+OU)
March 31,2022
Town of Southold
54375 Main Street
PO Box 1179
Southold,New York 11971
Re: Frame 1-1/2 Story Residence
3795 Main Bayview Road
Southold,New York 11971
To Whom it may concern.
Please accept this letter certifying that the above captioned house plumbing system and house wall,
ceiling and roof insulation was installed as per the New York State Building codes.
The above statement was made per my site observations of the above captioned residence.
If you have further questions regarding the above,please do not hesitate to contact the undersigned.
Very truly yours,
�FZED ARC
%,one tier
'4Ro0 F�
aul A.Lombardo,RA,A.I.A.
L/pl N
019003 O�
9TF OF NE�y
3939 New York Avenue, Seaford, N.Y. 11783 (516)398-7355 (FAQ (516)783-0085
Email: paWarc@aol.com
OFSOUjyOlo U �
ll 00 / 37q ��'," yvietv'
* # TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PL13G. t,
_4
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ] FIREPLACE &--CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/
REMARKS: -14-44L4-AA
C 044 avAlc�- tvl�Alet
�29 ar oF 17 ct/t✓L
o P
1�—L22- INSPECTORDATE �
vSOUIyo` H -7-7D O -j'715 MA t
* # TOWN OF SOUTHOLD BUILDING DEPT.
• ao
76S-1802
INSPECTION
[ ] FOUNDATION IST [ ] ROUGH PL13G.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING/STRAPPING [ ] FINAL
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION ] PRE C/O
REMARKS: �a /
DATE INSPECTOR -
Paul A. Lombardo, Architect
Paul A.Lombardo, RA,A.I.A.
March 7,2022
Town of Southold
54375 Main Street
PO Box 1179
Southold,New York 11971
Re: Septic System
3795 Main Bayview Road
Southold,New York 11971
To Whom it may concern.
Please accept this letter certifying that the 1500 gallon septic tank system installed at the above captioned
location connected with 8x4 overflow cesspools piped together is appropriately sized for the existing
Three(3)Bedroom residence at this location.
If you have further questions regarding the above,please do not hesitate to contact the undersigned.
Very truly yours, D ARC'S'/
�5 bOM$go
A1C! J p• �O� �+�
Paul .Lombardo,RA,A.I.A.
PL/p' N�q 0196 y0�
TF OF N��
3939 New York Avenue, Seaford, N.Y. 11783 (516)398-7355 (FAA9 (516)783-0085
Email: pa155arc(aaol.com
FIELD INSPECTION REPORT DATE COMMENTS , ^�
'�
FOUNDATION(IST) -+
y
------------------------------------
:PLA
. C
FOUNDATION(2ND)
C/4° C .►�
~ cli v� 1
ROUGH FRAMING& y
PLUMBING rf,
v V
-4 r
INSULATION PER N.Y. (b y
STATE ENERGY CODE
T3
Q
c
FINAL 1 A
n. AD ITIONAL COMME TS
riA-/) e—i
fL a G� ��2 D I oD6,
x
H
o��gUfFO(,�coG TOWN OF SOUTHOLD—BUILDING DEPARTMENT
>� y�
y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 hLtps://www.southoldtowm.gov
Date Received
APPLICATION FOR BUILDING PERMIT
For Office Use Only E. N�
/ I
PERMIT NO. q�q66 Building Inspector: MAR — 8 2022
Applications and forms must be filled out in their entirety. Incomplete YY �,T�„ ,d„sr
applications will not be accepted'. Where the Applicant is not the owner,an ,"'``````s �"�° n T.
pp p pp �•P :, Y. Eek w-11, u?�
'Owner's Authorization form(Page 2)shall be completed. t�'''` ''
Date:
OWNER(S)OF PROPERTY:
Name: C SCTM-#1000-
Project
1000-Project Address: 1
Phone#: �� 0yJ Email: ,1@�
Mailing Address: /L— j 11-7X3 l7 / 3
CONTACT PERSON:...
Ix-
Name:
Mailing Address: 7 1
- - � -- �e- fir_. . _ a�d� . � 70
Phone#: a Email:
DESIGN P FESSIONAL INFORMATION:
Name: Lo
Mailing Address: -4q3.2
Phone#: /�. Email: L .S-tf G
CONTRACTOR INFORMATION:
Name:
Mailing Address:
Phone#: Email:
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ARepair ❑Demolition Estimated Cost of oject:
❑Other $
Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? ❑Yes ❑No
1
PROPERTY INFORMATION
Existing use of property: Intended use of property:
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ❑Yes ONO IF YES, PROVIDE A COPY.
❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized.inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name): ❑Authorized Agent caner
Signature of Applicant: fjo� 1 /6-
Z5;/�d Date: 2
STATE OF NEW YORK) CONNIE D.BUNCH
SS: Notary Public,State of New York
COUNTY OF ) No.01BU6185050
Qualified in Suffolk County
Commission Expires April 14,2
being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract) above named,
(S)he is the
(Contractor,Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of ° M C , , 20
Notary Public
PROPERTY OWNER AUTHORIZATION
(Where the applicant is not the owner)
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
C* _ Town Hall Annex - 54375 Main Road - PO Box 1179
p ,v�L"F scv Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
rogerr(o)-southoldtownny.gov — sea ndCd).southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 4/28/2022
Company Name: Varsity Electrical Contracting Inc
Electrician's Name: Carmine Vandenberg
License No.: ME-38511 Elec. email:varsityelectric05@gmail.com
Elec. Phone No: 631-482-9216 ❑I request an email copy of Certificate of Compliance
Elec. Address.: 79 Harvest Lane, West Islip, NY 11795
JOS SITE INFORMATION (All Information Required)
Name: PGA Capital LLC
Address: 3795 Main Bayview Rd, Southold, NY 11971
Cross Street: Baywater Avenue
Phone No.: 631-560-9590
Bldg.Permit#: 47700 email:
Tax Map District: 1000 Section:78.00 Block: 2.00 Lot: 15.002
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
"as built" second floor bedroom and bathroom
Square Footage: 300
Circle All That Apply:
Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final
Do you need a Temp Certificate?: YES 0 NO Issued On
Temp Information: (All information required)
Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect[:]Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 FJ2 H Frame M Pole Work done on Service? Y N
Additional Information:
PAYMENT DUE WITH APPLICATION
�I
PERMIT# Address:
Switches
Outlets
G FI's
Surface
Sconces
H H's
UC Lts
Fans Fridge HW
Exhaust Oven Dryer
Smokes DW Service
Carbon Micro Generator
Combo Coo ktop Transfer
AC AH Mini
Special:
Comments.
i-
SVFFQ��- BUILDING DEPARTMENT- Electrical Inspector
=�4� C�r✓d TOWN-OF SOUTHOLD
o Town Hall Annex - 54375 Main Road - PO Box 1179 ,
CS ac
W- Southold, New York 11971-0959
*A �a®�� Telephone (631) 765-1802 - FAX (631) 765-9502
rogerr( _southoldtownny.gov - seand(cb_southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All information Required) Date:
Company Name:
Electrician's Name:
License No.: Elec. email:
Elec. Phone No: ❑I request an email copy of Certificate of Compliance
Elec. Address.:
JOB SITE INFORMATION (All Information Required)
Name:
Address: �j a kZ t/ f . -
Cross Street:
Phone No.:
-Bldg Permit#: (JC), - _.. - ----email:-
Tax Map District: , 1000 Section: Block: Lot:
BRIEF DESCRIPTION OF WORK, INCLUDE'SQUARE FOOTAGE (Please Print Clearly):
Square Footage:
Circle All That Apply:
Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final
Do you need a Temp Certificate?: ❑ YES ❑NO Issued On
Temp Information: (All information.required)
Service Size❑1 PhF-13 Ph Size: A # Meters Old Meter#
❑New servicer-1 Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 0 1 FJ2 n H Frame 0 Pole Work done on Service? 0 Y N
Additional Information:
- - - .-PAY-MEN--DUE-WI-T-H-APPL-ICA-T-ION- - -
SL � � I
/Wi ,TS /^y�, . can �io ri�3 ' �"2 � Itv!'dwin
� e / VIS 14
,-�-,�,
PLOT PLAN TYPOCAL [(MOTES d �
APPROVED AS NOTED
\ DATE: .P.#
EXIST'G ELE�CTI3lC/�!�
N���� FLOATING �'
.3
DOCK FEE: c PY: ����SPECTION nF-O .1IRE&)
@�
NOTIFY BUILC ivu I::EFARTMENT AT
J36� 765-1802 8 AM TO 4 I'M FOR THE
@
THE CURRENT RESIDENCE AS EXISTING In/
Gp APPROX. FOLLOWING INSPECTIONS:
I.HIGH WATER 1. FOUNDATION - TWO REQUIRED
pSF c Q LINE FOR POURED CONCRETE
PLUMBER CERTIFICATION
RESIDENCE ZONING ANALYSIS
._. ROUGH - FRAYING & PLUMBING _
/ �k N a
TOWN OF SOUTHOLD - SUFFOLK COUNTY - ZONE = R-40 ZONING DISTRICT N
. ON LEAD CONTENT BEFORE
INSULATION CERTIFICATE OF OCCUPANC Y
FINAL - CONSTPI!CTION MUST
BE COMPLETE F::��, C.O.
LOT COVERAGE / ALL CONSTRUCTION SHALL MEET THE SOLDER USED IN INA TER
LOT AREA 40250 SF EXISTING -1J2 STORY SUPPLY SYSTEM CANNOT
REQUIREMENTS OF THE CODES OF NEW
REQUIRED: IN R-40 DISTRICT s EXIST'G FRAME DWELLING YORK STATE. NOT RESPONSIBLE FOR EXCEED 2/10 OF 1% LEAD.
:
REQUIRED (MAXIMUM) 40250 SF (LOT) X 20 % = 8050 SF 24 4' DECK NO. 795 DESIGN OR CONSTRUCTION ERRORS.
�
EXIST'G /3
PROVIDED: MASONRYLY WITH ALL CODES OF
NEW O
EXISTING 1-1/2 STORY FRAME DWELLING (FOOTPRINT) 1250 SF STEPS EXIST'G STATE_ & TOWN CODES ,PLUMBING
WOOD /C4 AS REQUIRED AND CONDITIONS OF ALLPLUMI3INGWASTE
EXISTING REAR DECK/STEPS 200 SF EXIST'G STOOP `�n n T ^"�r &(NATER LINES NEED
STOC ,1�N 9+� - ,j MING 13EFORF COVERING
TOTAL 1450 SF (FOOTPRINT) FENCE
M" �- u BOARD
% LOT COVERAGE 1450 /40250 = .233% = 3.6 % w
_ -- S0�T'-I^I i���/�'N TPrf 14TEES
PROVIDED = 1450 SIF
? e CONSTRUCT 0 O N NOTES
! Additional
OCCUPANCY OR
FRONT YARD Im FENCE GENERAL NOTES:STOCKADE / USE IS UNLAWFUL y Ma ertification
ti �O Be Required.
REQUIRED: IN R-40 DIST. 50.0' MIN. WIT
THIS PROJECT TO COMPLY WITH THE 2020 RESIDENTIAL CODE OF NEW YORK STATE AND UT CERTIFICATE
PROVIDED: +/- 200.00' OK NO CHANGE e / ENERGY CONSERVATION CODE - ECCC (REVISED AUGUST 2020) OF OCCUPANCY
SIDE YARD 1. THE A.I.A. GENERAL CONDITIONS (A.I.A. DOC. A201) ARE HERBY MADE AN
i �/ 3 (q ADMINISTRATIVE PART OF THESE DRAWINGS, AS IF HEREIN WRITTEN IN FULL.
REQUIRED. IN R-40 DIST. 15.0' `� se, 2. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
PROVIDED: 39.3' OK NO CHANGEO„4 �" 3. LARGER SCALE DETAILS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS. IT IS
b THE INTENTION OF THE DRAWINGS TO PROVIDE FOR A COMPLETE JOB IN ALL RESPECTS AND
REQUIRED: AGGREGATE MINIMUM 35.0' NO EXTRAS WILL BE ALLOWED FOR MATERIALS AND/OR LABOR REQUIRED TO COMPLETE THE
PROVIDED: 104.2' OK NO CHANGE WORK, AS INDICATED.
EXISTING PLOT PLAN 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS ON THE JOB AND THE
ARCHITECT'S OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND
REAR YARD Scale : 1/64"=1'-0" CONDITIONS SHOWN ON THE DRAWINGS. PROVIDE DIMENSIONS SUBJECT TO ACTUAL FIELD
REQUIRED: IN R-40 DIST. 50.0' MIN. NOTE: COND- (TIONS AND NO CREDITS OR EXTRAS WILL BE ALLOWED FOR DISCREPANCIES UP TO
PROVIDED: +/-75.0' OK NO CHANGE INFORMATION TAKEN FROM SURVEY AS PREPARED BY: 2'-0" IN ANY MEASUREMENT.
PJM LAND SURVEYING, PLLC 5. CO:STRUCTION SHALL COMPLY WITH ALL FEDERAL,STATE AND LOCAL CODES, ORDINANCES,
132 CLYDE STREET SUITE 16 RULES AND REGULATIONS. CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS AND
WEST SAYVILLE, NEW YORK 11796 INSPECTIONS INCLUDING THE OCCUPANCY CERTIFICATE.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL
DATED: JANUARY 2ND 2020 WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, DISTORTION AND
TAX MAP DESIGNATION NUMBER MISALIGNMENT ACCORDING TO APPLICABLE CODES, STANDARDS AND GOOD PRACTICE.
~ DISTRICT SECTION BLOCK LOT 7. CONTRACTOR SHALL DISCONNECT, CAP AND REROUTE ANY EXISTING WATER SANITARY OR
• 1000 78 02 15.2 UTILITY LINES IN AREA OF NEW FOUNDATIONS AND SHALL USE HAND EXCAVATION IN AREAS OF
SUSPECTED UNDER GROUND UTILITIES AND SERVICES. IF ANY LINES ARE BROKEN OR DAMAGED,
THE CONTRACTOR WILL REPAIR AND REPLACE SAME AT HIS OWN EXPENSE AND ARRANGE FOR I® I® � ! l� T fly p I� I ' M /� T � O fly p
NOTES E L E C T FR � C A L NOTES 8
PROPER INSTALLATION
OF ALL ISMATERIALS AND PRODUCTS SHALL MEET ALL LOCAL FIRE
DEPARTMENT'S REQUIREMENTS AND REGULATIONS, PROOF OF WHICH SHALL BE FURNISHED TO NICK BARRETTA AND PHIL TESORIERO
1 . A minimum of one wall-switch-controlled lighting outlet is required in eTHE FIRE MARSHALL PRIOR TO THE INSTALLATION OF SUCH MATERIALS AND PRODUCTS. OWNER:
ery habitable g. MATCH ALL EXISTING CONDITIONS AS THEY RELATE TO FINISHES LIGHTING COURSING
room, hallway, stairway, attached garage, and outdoor entrance. Except'on: In habitable NICK BARRETTA AND PHIL TESORIERO
NOTE: rooms other than kitchens and bathrooms one or more receptacles control ed b a wall DIMENSIONS, HEIGHT, ALIGNMENT, ETC. MOVE AND RELOCATE ANY PARTITIONS, WIRING PLUMBING BUILDING USER / TENANT.
ARCHITECT IS NOT RETAINED p y AND DUCTWORK THAT MAY BE CONCEALED IN WALLS OR CEILINGS BEING REVISED, TO PROVIDE
CONTRACTOR/ OWNER IS switch are permitted in lieu of lighting outlets. A COMPLETE JOB IN ALL RESPECTS. PROJECT DESCRIPTION: TO MAINTAIN AN EXISTING RESIDENCE
FOR CONSTRUCTION 2. In every kitchen, family room, dining room, den, breakfast room, living r )om, parlor, 10. PROVIDE ALL BLOCKING AND SUPPORTS AS REQUIRED FOR FRAMING OF NEW AND EXISTING
RESPONSIBLE TO OBTAIN ALL sunroom, bedroom, recreation room, and similar rooms, receptacle outlets must be installed PROJECT SQUARE FOOTAGE: N/A
ADMINISTRATION . so that no point along the floor line is farther than 12 ft measured horiz )ntally, from an AREAS. INSTALL AND REMOVE (AFTER COMPLETION) ALL TEMPORARY SUPPORTS, HEADERS AND
NECESSARY PERMITS. outlet, including any wall space 2ft or more wide and the wall space occuF ied by sliding DUST SCREENS TO ADEQUATELY SUSTAIN ALL LOADS AND PROTECT EXISTING WORK FROM CONSTRUCTION CLASSIFICATION : 5B
panels in exterior walls. DAMAGES OF ANY KIND, INCLUDING DUST.
11
3. A minimum of two #12 wire 20-A small appliance circuits are required :o serve only small . FLASH, CAULK AND SEAL ALL JUNCTIONS OF NEW AND EXISTING ROOFS, WALLS AND
PENETRATIONS, TO TO FORM A WATER TIGHT ASSEMBLY. ALL FLASHING TO BE 16 OUNCEOCCUPANCY: RESIDENTIAL
appliance outlets, including refrigeration equipment, in the kitchen, pantry, lining room, COPPER SHEETHING AND EXTEND AT LEAST 8" ABOVE INTERSECTING SURFACES.
DE M O � � T � O N NOTES breakfast room, and family room. Both circuits must extend to the kitcher; the other rooms
I� may be served by one or both of them. No other outlets may be connect( d to these circuits, 12. ALL ELECTRIC WORK SHALL CONFORM TO RULES AND REGULATIONS OF THE NATIONAL
except a receptacle installed solely for an electric clock. In kitchen and dir ing areas, ELECTRIC CODE AND N.Y. STATE BOARD OF FIRE UNDERWRITERS. THE FINAL CERTIFICATE OF P R O J E C T E F11\ IIS !
1. Demolition work shall be done in strict conformance with local and state regulations. receptacle outlets must be installed at each and every counter space wide than 12 in. APPROVAL MUST BE PRESENTED TO THE OWNER PRIOR TO FINAL PAYMENT. � �l
4. A minimum of one #12 wire 20-A circuit must be provided to supply V e laundry 13, THE ENTIRE PREMISES, INSIDE AND OUT, SHALL BE CLEANED OF ALL DEBRIS AND EXCESS AO TITLE SHEET, EXISTING PLOT PLAN
2. Perform all demolition work in accordance with the regulations of ANSI/NEPA 241-1975, MATERIALS, TO THE SATISFACTION OF THE OWNER, INCLUDING LABELS AND PROTECTIVE
Building Construction and Demolition Operations. receptacle(s), and it may have no other outlets. COATINGS ON ALL MATERIALS. Al EXISTING 1ST & 2ND FLOOR PLANS
3. Provide all temporary barricades, railings, lighting, etc. re required to protect the workmen, 5. At least one receptacle outlet must be installed in the bathroom near -he basin and
P y gq P 14. REQUEST FOR FINAL PAYMENT MUST BE ACCOMPANIED WITH A WAIVER OF LIENS SIGNED
owner's personnel, and others from injury due to the demolition work. Provide free and must be provided with ground fault circuit interrupter protection. 6. Code requires sufficient 15- and 20-A circuits to supply three watts of power for every square fo )t of floor space, BY ALL SUB-CONTRACTORS AND MATERIAL SUPPLIERS, IN ADDITION TO THE GENERAL A2 EXISTING EXTERIOR ELEVATIONS
safe passage of persons to and from areas and facilities which are to remain. not including garage and open porch areas. Minimum code suggestion is or,e circuit per 600 CONTRACTOR. A3 EXISTING SECTION, DETAILS AND RISER DIAGRAM
4. Perform the demolition work in such manner as to prevent fires. Remove all accumulated gg
sq ft; one circuit per 500 sq ft is desirable.
debris promptly. Disposal by burning will not be permitted on site. All debris shall be CONCRETE AND MASONRY NOTES:
7. A minimum of one exterior receptacle outlet is required (two are desira )le) and must be
disposed of in a legal, workman-like manner. Do not bury materials on site. 1. ALL FOOTINGS SHALL REST ON SOLID, UNDISTURBED SOIL HAVING A MINIMUM BEARING
5. All salvageable materials and equipment including fixtures, furnishings, and decor items provided with ground fault circuit interrupter protection. CAPACITY OF ONE TONS PER SQUARE FOOT AS PER R401.4.1.
shall be stored and protected from damage until the owner determined the course of action 8. A minimum of one receptacle outlet is required in basement and garage , in addition to
the one in the laundry. In attached garages it must be provided with grou,ld fault circuit 2. WHERE SLABS ARE SUPPORTED ON FILL, THE FILL SHALL BE PROPERLY COMPACTED IN
to be taken with same. interrupter protection.
LAYERS, TO ACHIEVE 98 COMPACTION.
6. Notify affected utility companies before starting work and comply with their requirements.
3. INSTALL PRE-MOULDED EXPANSION JOINTS AROUND PERIPHERY OF SLAB AND AT ALL
7. Do not disable or disrupt building fire or life safety system without prior written notice 9• Many building codes require a smoke detector in the hallway outside bedrooms or above COLUMN LOCATIONS. JOINT MATERIAL TO HAVE INSULATION VALUE OF R-5 FOR BUILDING
to the owner. the stairway leading to upper floor bedrooms. CONSTRUCTION. 1 03 - 10 - 22 SUBMISSION TO THE TOWN OF SOUTHOLD, N.Y. BLDG. DEPT.
8. Provide dust-tight partitions between areas where demolition work is being performed 10. Disconnect switches are required. 4. ALL CONCRETE SHALL BE 1.2.4 MIX FC- 3,000 P.S.I.
and areas which are finished or in use. 11. Al Electric Meters to meet FEMA Guidelines for installation in the Flood Zone. / PAULA LOMBARDO ARCHITECT
5. INSTALL DUR-O-WALL TRUSS TYPE MASONRY REINFORCING 16 O.C. VERTICALLY AND AS EFtED A.
9. Conform to procedures applicable when discoveringhazardous or contaminated materials. Note: Refer to the National Electrical Code (NEC) for further information o l residential g'� e
pp requirements. PER MANUFACTURERS SPECIFICATIONS, IN ALL MASONRY WALLS. c,` 'yam
10. Conduct demolition to minimize interference with adjacent occupancies. q 6. STEEL REINFORCING BARS SHALL BE IN ACCORDANCE WITH A.S.T.M. A615GRADE 60 �'� 3939 New York Avenue
11. Cease operations immediately if structure appears to be in danger. Notify Q �' Seaford, N.Y. 11783
DEFORMED. * P (516)783-5430 Fax (516) 783 -0085
architect/engineer. Do not resume operations until directed. '°
7. MINIMUM LAP OF #4 REINFORCING BARS SHALL BE 20 AND FOR #5 REINFOCING BARS - � APPLICATION TO MAINTAIN EXISTING Drawn By Sheet No.
12. Demolish in an orderly and careful manner. Protect existing supporting structural
26 '. '� �'96'S �°�-
members. RESIDENCE LOCATED AT
13. Patch all existing finishes to remain that are affected by adjacent demolition work. 8. VERTICAL WALL EXPANSION JOINTS SHALL BE INSTALLED NO MORE THAN 30'-O" O.C. �FNE`N AO
Scale
14. Leave each area broom clean upon completion of work each day. JOINTS TO BE "DUR-O-WALL" RAPID CONTROL JOINT N0. 8. 3795 MAIN BAYVIEW ROAD, SOUTHOLD, N.Y.
Drawing: TITLE SHEET - EXISTING PLOT PLAN 1 of 4
A
A3
EXISTING 31X20
OPERABLE SKYLIGHT EXISTING i EXISTING STAIR AND EXISTING
(TYP FOR 2) ATTIC
HANDRAIL TO REMAIN ATTIC
CLQ zw
i i i i
Ti ' ' ' � x
L--------J L--------J X11"
111
- z
(s))
z o EXISTING z EXISTING zip
LE) OOM O o ° LIVINCx ROOM N u
SH o w BELOW w
TI EXISTING
LOFT
zw
O CO SD
X
EXISTING
ATTIC:
A
EXISTING A 3
SE CONDI FLOOR PLAN
scale : 1/4" = 1'-0"
A E WITH NEW DECKING
A 3 AND HANDRAILS
EXISTING EXISTING EXISTING
28X54 DH 28X54 DH 28X54 DH
WINDOW WINDOW WINDOW
EXISTING UP -
CLOSEt
EXISTING
(;L. BEDROOM 2
EXISTING
z °
O
xX - z
01 EXISTING
- LIVING/DEN
CL OPEN TO ABOVE L E E N
EXISTING
WALL T'I'1=E5
HALL EXISTING PARTMON
EXISTING
E1"fERr:sENC'I' ESCAPE 4 RESCUE OI=ENINCz
z o ( Linen /DRY ° C 8310.1.1
.d FRIDGE
EXISTING BATH 1 UTILITY KITCHEN
BEDROOM 1 r EXISTING EXISTING EXISTING
o ORANGE
EXISTING 6068 SLIDING EXISTING 3646 EXISTING 29X30 EXISTING 6068 SLIDING
DH WINDOW CASEMENT
WINDOW
A
A 3
EXfSTING
F I R5T FLOOR PLAN
A EXISTING PLATFORM
�t NO CHANGE
scale : 1/4'1 = 1'-O" NO I.UORK "
1 03 - 10 - 22 SUBMISSION TO THE TOWN OF SOUTHOLD, N.Y. BLDG. DEPT.
DAR y PAUL A. LOMBARDO ARCHITECT
OM 3939 New York Avenue
J A Seaford N.Y. 11783
* a e I (516)783 -5430 Fax (516) 783-5430
N r Drawn By Sheet No.
019615 0� APPLICATION TO MAINTAIN EXISTING
FOF N��Ny RESIDENCE LOCATED AT Scale
A I
3795 MAIN BAYVIEW ROAD, SOUTHOLD, N.Y.
DATE: Drawing: DESIGN FLOOR PLANS 2 of 4
EXISTING SKYLIGHTS
EXISTING ASPHALT ROOF
T.O. PLATE
T.O. PLATE T.O. PLATE
--ELEV_ + 16'-3i1z�� — LE
16'-311/2
EXISTING WINDOWS AND
DOORS
EXISTING FACIA AND EAVE
EXISTING FACIA AND
EAVE
EXISTING FACIA AND T.O. CLG HT.
EAVE ELEV. + 7'-11"
T.O. 2ND FLOOR T.O. 2ND FLOOR T.O. 2ND FLOOR
�— --- -- --------- - -- V.__±8-m!z
T.O. C:LG WT.
ELEV. + I'-1111 .O. C G
ELEV. + -i'-11" EXISTING VINYL SIDING
EXISTING WINDOWS EXISTING VINYL SIDING
EXISTING PARSED
CONCRETE FOUNDATION
WALLS
T.O. 'IST FLOOR Li T.O. IST FLOOR T.O. IST FLOOR
ELE'✓. + 0'-0" ELEV. + 0'-0" ELEV. + 0'-0"
GRADE
GRADE GRADE GRADE
EXISTING PLATFORM EXISTING SINGLE HUNG
EXTERIOR DOOR
EXISTING EXISTING
FRONT (WE6T) ELEVATION 61DE (NORTH) ELEVATION
EXISTING ASPHALT ROOF
T.O. PLATE T.O. PLATE
ELEV. + 16'-3�is" ELEV. + 16 -3�
---------- --- - ---- ---- ----- 2•------- ----
EXISTING FACIA AND
T.O. 2ND FLOOR EAVE T.O. 2ND FLOOR
8'-10�is" ELEV. + 8'-101/2"
------ ----
T.O. CLG HT. T.O. CLG HT. EXISTING WINDOWS AND
ELEV. + -P-11" ELEV. + -f'-11" DOORS
EXISTING VINYL 511DING
T.O. 15T FLOOR EXISTING PARSED T.O. IST FLOOR
ELEV. + 0'-0" CONCRETE FOUNDATION ELEV. + 0'-0" EXISTING WOOD DECK AND PLATFORMS
WALLS Ll
GRADE GRADE GRADE
EXISTING; EXISTING
51DE ( 60UTH) ELEVATION- REAR (EA6T) ELEVATION
scale 1/4 = 1 -0 11 scale 1/4" -
- 1'-O'' 1 03 - 10 - 22 SUBMISSION TO THE TOWN OF SOUTHOLD, N.Y. BLDG. DEPT.
-
PAUL A. LOMBARDO ARCHITECT
Gig ERE q
3939 New York Avenue
om Seaford, N.Y. 11783
(516)783 -5430 Fax (516) 783-5430
`� 4z C-
Drawn By Sheet No.
7o;96 * APPLICATION TO MAINTAIN EXISTING
�N5'Yo � RESIDENCE LOCATED AT scale A2
3795 MAIN BAYVIEW ROAD, SOUTHOLD, N.Y.
DATE: Drawing: EXISTING EXTERIOR ELEVATIONS 3 of 4
SPLICE LENGTH
BUILDING DIM. (FT.) MIN. SPLICE LENGTH (FT.)i,Z3.4
STFAF= INS 4 ANCHOF,)ING 3CHEEDULE 12 1
AREA HOLDDOWN USED / LENGTH NUMBER OF CAPACITY OF NOTES 16 1
NAILS HOLDDOWN H 20 2
SPLICE DIRECTLY
RIDGE SIMPSON CS-20/24" MIN. LENGTH 3-1Od 1005#/CONNECTION RIDGE STRAPS ARE NOT REQ'D WHEN 2"X4" OVER STUD TYP. 24 2
COLLAR TIE IS LOCATED WITHIN THE UPPER THROUGHOUT 28 3
1/3 OF THE ATTIC SPACE AND ATTACHED TO II II 32 3
EACH PAIR OF OPPOSING RAFTERS AS PER DBL. TOP PLATE
WFCM 1995 SECTION 3.2.5.1 TYP. THROUGHOUT 36 3
DORMER RIDGE SIMPSON CS-20/24" MIN. LENGTH 2-10d 1005#/CONNECTION SEE NOTE ABOVE 40 4
EAVE SIMPSON H-7 ANCHOR 4-8d TO RAFTER 845#/CONNECTION PER RAFTER 50 5
8-8d TO STUD
2-8d TO PLATES 60 6
DORMER EAVE SIMPSON H-7 ANCHOR 4-8d TO RAFTER 845#/CONNECTION PER RAFTER 1. TABLULATED SPLICE LENGHTS ASSUME TOP
8-8d TO STUD PLATE-TO-PLATE CONNECTION USING 2-16d
2-8d TO PLATES NAILS PER FT. FOR SHORTER SPLICE LENGTHS,
CEILING TO WALI SIMPSON CS-20/36" MIN. LENGTH 26-8d 1005#/CONNECTION PER STUD TTHE
PNAIL
SPANING EQUIVALENT SHALL BE REDUCED
UMBER INNORDER
FLOOR TO FLOO1 SIMPSON CS-20/36" MIN. LENGTH 26-8d 1005#/CONNECTION PER STUD WALL FRAME AT 16" O.C. 2. TABLULATED SPLICE LENGHTS ASSUME A
FLOOR TO FOUNDATION SIMPSON STHD14RJ 4160#/CONNECTION AT FOUNDATION CORNERS- -REFER TO PLANS BUILDING LOCATED IN EXPOSER B OR C.
HOLDDOWN ANCHOR 36-16d SINKER FROM FDN. WALL TO WOOD 3. TABLULATED SPLICE LENGHTS ARE BASED
CORNER POST ON 8 FT. WALL HTS. FOR OTHER WALL HTS.,
FOUNDATION TO SILL SIMSPON SSTB-16 PLACED 120 #/FT. H, THE TABULATED UNIT LATERAL LOADS
18" MIN. LENGTH 4'-0" 0.C. TABLE 3-2 WFCM SHALL BE MULTIPLIED BY H/8.
4. TOP PLATES SHALL BE A MINIMUN OF
*NOTE: ALL STRAP AG INDICATED MEETS OR EXCEEDS THE REQUIRMENTS IN THE WOOD FRAME CONSTRUCTION MANUAL 1995 EDITION TABLE 3.6 FOR RIDGE CONNECTIONS, TABLE 2.2 FOR EAVE STUD GRADE MATERIAL.
CONNECTIONS, AND TABLE 3.2 FOR FOUNDATION CONNECTIONS. AS PER WFCM 1995 EDITION FOR
*NOTE: ALL STRAP ; BY 'SIMPSON STRONG-TIE' SHALL BE INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS. ANY NEW, UPDATED OR CONFLICTING INFORMATION PROVIDED BY SIMPSON ONE AND TWO—FAMILY
SHALL TAKE PRESE)ENCE OVER THIS SCHEDULE. DWELLINGS TABLE 3.20
4 11 VTR I EXISTING ROOF TRUSS RAFTERS
CHORDS AND INTERMEDIATE
I FRAMING MEMBERS - "NO CHANGE"
,4- T I C I AND TO REMAIN UNTOUCHED. EXISTING ROOF TO REMAIN
�
ROOF I EXISTING 60 CFM EXHAUST
FAN WITH DIRECT VENT TO
EXTERIOR
EXISTING I I ,
BATH Rl� I I EXISTING 2X4
T.O. PLATE TRUSS AND ��\ ATTIC
CEILING
F — — --I — - - — -I- — — � � --- ELEV.__ + 16'-Im�iz�� -- ----- -- MEMBERS
111/2 " 111/� " 111/2 " I I ---
EXI5TING FLOOR CONSTRUCTION ��'° PBD
1 3/4" PLYWOOD ATTAVHEC TO FLOOR JOISTS
L z V 1 UiC I EXI5TINCa
HE I TINCs
SIS I I 1 TN MALL
1= OOR Co. 2 i I
ATTIC ATTIC EXISTING
XITI F FLOOR JOISTS -
— — I T.O. 2ND FLOOR
ELEV. + 8'-101/2 --
EXIST N�GI EXISTING EXISTING
13T.O. CLC, HT,
BATH RMI. I KITCHEN UTILITY ELEV. + 8'-0" s LIBLLATE
BD
7 — - - - - �— —I- - - -T - - - - - TYPICAL
j
11/2 "- 1 1 I ) 11/2 1 11/2 " I 11/2 BATT INSULATION IN - EXISTING FLOOR AND WALL
I I I r I '11/2 11 111/2 " EXISTING WALLS EXISTIrs EXISTM EXISTIrs CONSTRUCTION TO REMAIN
CONSTRUCTION
I I I I I 1 UTILITY MALL KITCHEN
FAT I I AJC I L,4V � DUJ I i <.&IN< I LU,4S44ER
1 ST iTUB 1 I � 1 T.O.
EST FLOOR .
FLOOR I 3�0 11/211 1 11/2 I co
Zi
5,45E LENT I J // / GRADE EXISTING GRADE
CRAWL SPACE
TO
IN 5TREETLl--,—EXISTING CONCRETE HOUSE
&ANITAR'I' HOUSE T z,4P IN PIT FOUNDATIONS
NCHANGE
NFOOTINGS TO
,SEWER EX I ,5T ING
EX IS TING C -'056 5E CT I ON A - A
PLU 51NG R15ER DIAGRAM-
1 03 - 10 - 22 SUBMISSION TO THE TOWN OF SOUTHOLD, N.Y. BLDG. DEPT.
DAR PAUL A. LOMBARDO ARCHITECT
°`�P,°�►s '�
3939 New York Avenue
(516)783-5430 Seaford, N.Y. 11783 Fax (516) 783 -5430
Drawn By Sheet No.
N o;9 5 ��" APPLICATION TO MAINTAIN EXISTING
FIN RESIDENCE RESIDENCE LOCATED AT Scale
3795 MAIN BAYVIEW ROAD, SOUTHOLD, N.Y. A3
DATE: Drawing: EXISTNG SECTION, & PLUMBING RISER 4 of 4