Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
45492-Z
Town of Southold 6/29/2022 a P.O.Box 1179 . 0 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43202 Date: 6/29/2022 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 1000 Hillcrest Dr, Orient SCTM#: 473889 See/Block/Lot: 13.-2-8.27 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/13/2020 pursuant to which Building Permit No. 45492 dated 11/24/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory in-ground swimming pool fenced to code as applied for. The certificate is issued to Chrisbobjo Corp of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45492 3/7/2022 PLUMBERS CERTIFICATION DATED 0 Aut ri ed S' tore ` TOWN OF SOUTHOLD BUILDING DEPARTMENT a� TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45492 Date: 11/24/2020 Permission is hereby granted to: Chrisbobjo Corp 1000 Hillcrest Dr Orient, NY 11957 To: construct accessory in-ground swimming pool as applied for. At premises located at: 1000 Hillcrest Dr, Orient SCTM # 473889 Sec/Block/Lot# 13.-2-8.27 Pursuant to application dated 11/13/2020 and approved by the Building Inspector. To expire on 5/26/2022. Fees: SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $250.00 CO - SWIMMING POOL $50.00 Total: $300.00 Bu' ing Inspector OF SO�j�Ql � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devlintc�i_town.southold.ny.us Southold,NY 11971-0959 Q �yCOUNTI,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Chrisbobjo Corp Address: 1000 Hillcrest Dr city:Orient st: NY zip: 11957 Building Permit#: 45492 Section: 13 Block: 2 Lot: 8.27 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: South Electric License No: 58024ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor X 1st Floor Pool X New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt 2 Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks 2 Disconnect Switches 2 4'LED Exit Fixtures Pump 2 Other Equipment: Intermatic Pool Panel 8 Circuit/6 Used, Salt Generator, Heater, Pump, Cleaner Purl Pool Cover w/ Key Locked Switch Notes: Pool Inspector Signature: ��. Date: March 7, 2022 S.Devlin-Cert Electrical Compliance Form HM ENGINEERING P.C. P.O.BOX 914 EAST NORTHPORT,NY 11731 TEL:516-476-5392 EMAIL:HMARNIKA@OPTONLINE.NET November 4, 2020 Town of Southold Building Department Town Hall Southold,N.Y. 11971 Dear Sir/Madam: This is to certify that the drainage facilities to be used exclusively for the construction of a swimming pool on the premises of- Johnson Residence 1000 Hillcrest Drive Orient,N.Y. 11957 will not require draining because the pool is constructed with a vinyl liner. The pool water will be continuously recirculated through the filter and will be reused from year to year. The drainage from the filter backwash will be piped to a drywell located on the subject lot and will not interfere with the public water supply system, existing sanitary facilities, adjoining property owners, public highways or private roads. Sincerely, FHM E ineering P.C. q w of arnika, P.E. oe souryolo U Cl O 441 L L C * # TOWN OF SOUTHOLD BUILDING DEPT. . �ourm, 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]° INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [_ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: a�ti ` , 0NG e 41-,�*ck DATE 3 INSPECTOR pf SOUTyp� Li 5_4 12 / 04-0 //ctc �--epf # # TOWN OF SOIJTHOLD BUILDING :DEPT. 765-1802 / Or 0,C) �r INSPECTION -� [ ] FOUNDATION 1ST [ ] ROUGH PLBG. ' [ ] FOUNDATION 2ND .. [ _ ] ,INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ]-FIREPLACE &CHIMNEY [- ] FIRE SAFETY-INSPECTION'. [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ]" ELECTRICAL (ROUGH) [� ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE-C/O REMARKS: ©.SZc�i t'ta.� v 1D W t r rA K�r1QA� c—oM4p"TM.A1lr l" C 0✓'� Sde, CIA .fUAICAal d 92 1 WA cevel- AV 4T—I CAW 0 _r&_23 A":::� DATE P9 INSPECTOR � ` i 0ESoUTyo� 45T?Z ® aa f-f # * TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: ` a�c_ "ir- , vety 0 n2v AND 7) t 9-COMV �7 W1 Lt 1- DATE :2 �' INSPECTOR J - u cy Gr- -- _ O��OF SO!/THp 1000 � - # # TOWN. OF SOUTH.OLD BUILDING DEPT. °��courm � 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND f. T "INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL ] FIREPLACE & CHIMNEY ' [ ] FIRE SAFETY INSPECTION" [ ] FIRE RESISTANT CONSTRUCTION [ . ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION rl PRE C/O REMARKS: xo 6711 DATE > INSPECTOR �'' of so TOWN OF_ SOUTHOLD BUILDING DEPT. °`yibmm 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND , [ ] -INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY- [' ]-FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION ,. [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE *Z� INSPECTOR q oF souryo } # TOWN OF SOUTHOLD BUILDING DEPT. �ycoutm,� 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL o1".1 4 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: qmkL, btcj DATE INSPECTOR 50U1,�°! * # TOWN OF SOUTHOLD BUILDING DEPT. "Cou631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] ISULAPI AULKING [ ] FRAMING /STRAPPING [ FINALP—e [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: DATE INSPECTOR t FIELD INSPECTION REPORT DATE COMMENTS- ro FOUNDATION(IST) _may ------------------------------------ c �7 FOUNDATION(2ND) . O ' ! ROUGH FRAMING;& PLUMBING } INSULATION PER N.Y. STATE ENERGY CODE Y Qin., MeWo , JPJ�1 Ayh�✓ f FINAL Z t ADDITIONAL COMMENTS S v"y 3-�—a-a cam* ca z m y O. z k� • tai ro H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631).765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined �—,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: T Approved 20jgU Mail to: . owo MGLQ -1 r) Disapproved a/c /�l&O�+N Phone:p 4,31 76S a?S l Expiration 20 L( . POU 1ca-f-2, e mo-1 But mg nspector APPLICATION FOR BUILDING PERMIT Date ,20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Re lations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The �K'1 applicant Agrees to.cotpt lysvith all applicable laws,ordinances,building code,housing code,and regulations,and to admit D1 Ct ffi ized�i Ccc'"tol bn_f relnis e s and in building for necessary inspections. N0 V 1 3 2020 (� <•F i ature o a li ant or name,if a corporation) bw (Mailing address of applicant) r,';'tatewhatfieLapplianti's:caner,lessee agent,architect,engineer,general contractor,'electrician,plumber or builder A si=nC't Name of owner of premises —30V\V\aPe--, (As on the tax roll or latest deed) If applicant i cp o on,si nature of duly authorized officer (�1\ 4(Jl..� (Name and title o corporat officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Es (0 1. Location of land on which proposed work will be done: I (Doo 1+3 11 c��s-���'�- C7rk CA- �➢ � House Number Street Hamlet CountyTax Map No. 1000 Scction—'k�> Block Lot �� Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy sr - n b. Intended use and occupancy f.S 1 At-4,-'Ti 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work '�Tr2oi (Description) 4. Estimated Cost ,0 Dy Fee 3r� (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 2-cs k Az ffi e(�J 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO N 13.Will lot be re-graded?YES NO // Will excess fill be removed from premises?YES NO > 14.Names of Owner of premise0�j2��( h14ShAddress Phone No. C? Name of Architect Address Phone No Name of Contractor VCC[ Address Phone No. 1 �gn 's-109 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X. *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO-�L *IF YES,PROVIDE A COPY. STATE OF NEW YORK) S: COUNTY O q 5 Cl' p!� being duly swom,deposes and says that(s)he is the avoTRACEY L. DWYER (Name of individual signing contract)above named, NOTAR. ,,UBLIC,STATE OF NEW YORK NO.01 DW33w= (S)He is the QUALIFIED IN SUFR)ii,r COUN`y (Contract r,AgQ,Corporate Officer,etc.) COMMISSION EXPIRES JUNE 30, of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. sworn core o;bc ore me this L "-day of 0 U M 20 0 o c - otary Public Signature o Ap licant Building Department Application AUTHORIZATION (Where the Applicant-is not the Owner) I, //' / Sc�i✓ residing�10ftwJ at l ad,O �b r�•f (Print property.owner's name) (Mailing Address) ✓� D�L Qr��'e�� �/•y �t 9S�� do hereby authorize e- Agent) to apply on my:behalf to the Southold Building Department. (Owner's SidAture) (IJM4 r�to✓c'r� � c/yf rvS'��n/ - (Print Owner's Name) 0 i i g�FEpL:,r`,: BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD �- Town Hall Annex - 54375 Main Road - PO Box 1179 Southold,-New York 11971-0959 y Off: Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrOsoutholdtownny aov sea nd(Dsoutholdtownny.pov APPLICATION FOR ELECTRICAL-INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Na -me: eQ� c1 Name: vri License No.: ��h�� ,f�,t✓ email: L"�.��SLC�-�•� Phone No:.. ov quest an email copy of,Certificate.of, Compliance Address.: , � '�-► JOB SITE INFORMATION (All Information Required) Name: 6 bei- oar Address:. lb o Cross.Street: Phone No.: 9 V—.— 51—: Le Bldg.Permit.#: ::email: Tax Map District: 100&'' Section: 1'3 Block: °a, Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) do� Check All That Apply: Is.job ready for inspection?: [ Y S ❑NO .[Rough In ❑Final Do you need a Temp Certificate?: ES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 02 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx T AA M � o � /Vl ori HM,ENGINEERING P.C. P,O.BOX-914, EAST NORTHPOR,tMY 11731 TEL:516-476-5392 EMAIL:HMARNIKA90PTONLINE.NET November 4, 2020 Town of Southold Building Department Town Hall Southold,N.Y. 11971 Dear Sir/Madam: This is to certify that the,drainage facilities to be used exclusively for the construction of a swimming pool on the;premises of: Johnson Residence 1000 Hillcrest Drive Orient,N.Y. 11957 .the ;pool is constructed with'a vinyl liner: The pool water will be will not.require draining because continuously recirculated through the filter and will be reused from year to.year. The drainage-from the; filter backwash'will be pipedtto a drywell located on the subject-lot and will not interfere with the public water supply system, existing sanitary facilities, adjoining property owners, public highways or private roads. Sincerely, HM E ineering P.C. of arnika,P.E. CAST IRON FRAME a COVER IF UNDER PAVED AREA FINISHED GRADE 8' MIN. - 12' MAX. 24• x NOTES: BRICK LEVELING COURSE � MIN as CONCRETE COVER 1. UNSUITABLE MATERIAL SHALL BE REMOVED UNDER LEACHING POOL UNTIL PRECAST CONC. COLLAR 27' c�On 6' MINIMUM PENETRATION INTO VIRGIN STRATA SAND AND GRAVEL AND AS REQUIRED MAX BACKFILLED WITH SAND AND GRAVEL TO BOTTOM OF BASIN. PRECAST 2. AS AN ALTERNATIVE TO THE DOME TOP, A FLAT SLAB CAN BE REINF. CONC. SUBSTITUTED WITH APPROVAL OF THE ENGINEER. DOME 4'0 PVC 3. LOCATION OF DRAINAGE POOL TO BE DETERMINED BY OTHERS. MIN. S 1/8' "E' PERE FOOT ® ® ® 4. ALL DRAINAGE PIPES MUST BE PROVIDED WITH A MINIMUM 2'-0" COVER. INVER ® ® ® NON-SHRINK ® ®0 �j� 5. COLLAR IS NOT REQUIRED WHEN RATEABLE MATERIAL EXISTS FOR GROUT FULL DEPTH. ®O 3' MIN. SAND 6. THE MATERIAL USED FOR COLLARING SHALL BE COMPRISED OF SAND s AND GRAVEL AND GRAVEL CONTAINING LESS THAN FIFTEEN (15) PERCENT FINE SAND, CL COLLAR (TYAROUND o in SILT AND CLAY. SILT AND CLAY FRACTIONS ARE NOT TO EXCEED (5) m ALL AROUND y a PERCENT. W PRECAST REINF. > CONC. LEACHING u RINGS W1.6 a \y W ;r 8' DIAMETER wa �W v o DRYWELL CALCULATION: =M BACKWASH FROM POOL 70 GPM @ 5 MIN. = 350 GAL. (47 CF) DRYWELL CAPACITY = 1,263 GAL. (168.8 CF) z 6' MIN, PENETRATION CU a INTO VIRGIN STRATA 1z OF SAND a GRAVEL GROUND WATER 0 DRAINAGE POOL DETAIL NOT TO SCALE PREPARED FOR: JOHNSON RESIDENCE 1000 HILLCREST DRIVE ORIENT, N.Y. 119 7 NOTE: �i DATE: 11/04/2020 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF HM ENGINEERING P.C.UNAUTHORIZED HM ENGINEERING, P.C. SCALE: NOT TO SCALE 66 ZV'L� SHEET: 1 OF 1 ALTERATIONS OR ADDITIONS TO THESE DOCUMENTS ARE A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE P.O.BOX 914 EAST NORTHPORT,NY 11731 EDUCATION LAW.INFRINGEMENTS WILL BE PROSECUTED. Tel:(516)476-5392 Fax:(631)980-7671 www.hmarnika@optonline.net VOID WITHOUT RAISED SEALAND BLUE SIGNATURE DRYWELL DETAIL d o ` Op • �n Fe Q �C �4o tie a 6� L r®� It -- ?;r V t 1 _ "ALL �YO ' u ' �•��. r • '� wBLu. 0< I MAP Lwg ! O / 1 ZEST HOLE 1•� 1 11 � 12.31-03 EL•105.3 1 I co�/� 6Rx.1. BILTY LCAM COL) EL. V p C o •cF \ 'I 11 I04A C N o V) V 6Roxu1J VI WLT CMU EL. J do. ya 0 ` BRu.SILTY m � ' sauo IulTu I 107.GRAVEL 3 A (9M) eL. o W So' Iwl. iS 91.3 l .J r' SILTY SAUD 'Q b I.c.• J cP o � 24.s• m 4e.3' •� �p (° WATER W lrJa O N GAR. I 2 STY. FR. HO Z Aar•lo4.s I d rn SAN.SILTY pRrVEWAy N I RE$.ftoxo SAND (SMI) •� '� 1 STY EL. Fr=/06.3 G.,3 5 � N ..� 4e.3' .3 51. � J VJAT"10 1- J FINE SAN i SAND (8P) W 50.3 0 d, p0 o ' e° A. ?S 143. N �p FO 14LET •• Te,9, A• 9S.'D De 94.1 "l7 CD i•' N I L CREST I,o.a Is.-It ,+ co :rm 94.6 n`. �• •. O /xyHN CeNe. MoAb 1"•IFIS, LYG C.I. I No-r I e TCN I I` SUBJECT 10 VEI AMTS F Rtsc CTi� 9 Llt�fl SLIRVE-Y of LOT' 2S j b PAGE 8 OP1 MAP of 1. I"Nt4ra McUcarb JIn HILUCREST m OF �S`l"AT ES, 8 C FCtOLY.COIJNW DFP E"j-C='`^LTr14 N10EEi yCPgl G•y�i� ,T; 02 F1LEp MAP No•-12 18 A?Pi:O''1 !'-: _,--..__.,.F AT ORIEtJ T AS�NGL'm L) (\ 'toW►.l of SouTHoLD Date SEP 3 0 2005 s,s.t�f.e;,, do o`f - SUFFOI.K C ♦( `d. ;;'frr ..;c'.tl;: t nS'vubeen `F ti• S.C.T. OUI.1T111 1J Theera( found to ss N1. 1000-13-O'L-t3.2 IrspeCe� nd'arc'tifiedhyl.:^L'S"?s N _ E+ AtZ�A 5db5i3Ct FORA t.L1XI;:;J?p _ 40,C.28 SF °"1 _ - Watter J,tiii 3Zt, ` M�Qu I LK I iJ >cL6V. t►J ASSUMED DATUM I:, cffice of Wastewater Management A 7 SUrLVEYIIJG IlnnlnMnieed.haounn n.aJJiliun ui Ni.wnq ix MAt1 ovrnlalinn of uclixm P_pv MlM1e New 1'mA Sill,Sill, E=AST .l S-r ee K.h n Imt C wFln of Ihn sun'c ma nnl hce n rbc LmE buns cvc nAad nv cmM cd zeal ix M A 1SL1 P y It 130 Iry—11dv&-1 he a one cnlid enhJ Uislmttc sh,n,n frmm PxrTell)'Lnex In«Iilinp 9Ne1u1N en fir.tpecinc llurryv.undux minl arr nm iruenJcd ingpidemthe ercaimnwflinccx pr rvhn F/NAL nrnswe, Crnililalixm Imlicmad Mx,w shell nm mh m the pelsun fnrwM�m the sunc!i` MAID.CONST.: 4.27-o¢ SC •E.= t' a 30 ImFr[d en01m hn behalf.In the atmlranr ry agennex:ruled hermn m,J nn the axxipo<x of lha lend'm Ilubmlxw lenilinurnxan ran vanclMhlumaddiuonal inahaxn.ry xu mnurnrrx REV.:2-23-OQ. Df -: �.Q1J. 2Oo4 t000' WILL CREST DR. Jc llo. G2855-d3 V i 1 APPROVED AS NOTE DATE: P.# FEE: NOTIFY BUILDING ARTMENT AT ELECTRICAL 765-1802 8 AM TC 4 PM FOR THE INSPECTION REOUIRED FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CDMPETE 2. ROUGH - FRAM'-;' PLUMBING 3. INSULATION 4. FINAL - CONS'-`, MUST BE COMPLE ALL CONSTRUCTi,.' - �LL MEET THE REQUIREMENTS OF I'HE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. RETAIN STORM WATER RUNQFF PURSUANT TO CHAPTER 236 COMPLY WITH ALL CODES OF OF THE TOWN CODE. NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF H9LD- T9W�Z3A_ �t�l8t$�6+�Rt-P�G.BOARD `39A4eaT0tfi VWEES QsikFhI ED,I ATELY.. ENCLOSE POOL TO CODE `'UPON COMPLETION BEPORE"WATER" OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE' OF OCCUPANCY NOTES: 1.POOL AND PROPERTY TO CONFORM TO 2020 NYS UNIFORM FIRE PREVENTION AND BUILDING CODE,TOWN OF "A" FRAME & CONTINUOUS CONCRETE SOUTHOLD CODE AND 2017 NATIONAL ELECTRIC CODE. BASE AT PANEL COLLAR (ENTIRE PERIMETER) 2.POOL SHALL CONFORM TO ANSI/APSP/ICC 5 STANDARDS R326.3.1. JOINTS (TYP.) SEE DETAIL THIS SHEET 3.SECTION R326.7 POOL ALARM REQUIRED. 4.ENTRAPMENT PROTECTION REQUIRED SECTION R326.5. . y: : •_ .• :• :�• 5.POOL SHALL COMPLY WITH BARRIER REQUIREMENTS SECTION R326.4. ' :'� �., ;�'' :.: •' ' 6.POOL SHALL COMPLY WITH 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NYS SECTION R403.10: POOLS AND PERMANENT SPA ENERGY CONSUMPTION(MANDATORY). SECTION R403.10.1 HEATERS \ SECTION R403.10.2 TIME SWITCHES STEPSI \ SECTION R403.10.3 COVERS •' 7.SLOPE PATIO SURFACE 1/4"PER FOOT(MIN.)AWAY FROM POOL. 8.LOCATION OF PROPOSED SWIMMING POOL AND POOL EQUIPMENT BY OTHERS.LOCATION TO COMPLY WITH LOCAL TURNBUCKLE ZONING REQUIREMENTS. 5/6" DIA. THREADED 9.BACKFILL MATERIALTO BE FREE DRAINING GRANULAR MATERIAL(NO CLAYOR LARGE ROCKS). PANEL ROD BOTH ENDS QPQ � I I 10.FILL POOL WITH WATER PRIOR TO BACKFILLING. 20' emmum PCL •'• 11.POOLTO REMAIN PERMANENTLY FILLED. 12.ALL DRAIN COVERS TO MEET ALL REQUIREMENTS OF THE VIRGINIA GRAEME BAKER(VGB)POOL AND SPA SAFETY ACT. 800 9.F• I I 'a'r . 13. NO DIVING EQUIPMENT PERMITTED. I 14.CONTRACTOR SHALL VERIFY SOIL BEARING LOADS PRIOR TO INSTALLATION OF POOL STAKE 15.THIS PLAN IS FOR CONSTRUCTION ON PROPERTY AT 1000 HILLCREST DRIVE,ORIENT,N.Y.11957 ONLY. CONCRETE 16.HM ENGINEERING,P.C.SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS,TECHNIQUES OR 6" X 30" MIN. / PROCEDURES UTILIZED BY THE CONTRACTOR,NOR FOR THE SAFETY OF THE PUBLIC OR CONTRACTOR'S EMPLOYEES,OR FOR THE FAILURE OF THE CONTRACTOR TO CARRY OUT THE WORK IN ACCORDANCE WITH THIS PLAN. HORIZONTAL BRACE 17.SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/APSP/ICC 7. 18.NO SURCHARGE ALLOWED WITHIN 4'OF SHALLOW END AND 6'OF DEEP END. ALTERNATE 0 A a FRAME DETAIL 40' NOT TO SCALE POOL PLAN NOTE: FILTER NOT TO SCALE THIS IS A NON-DIVING POOL. PUMP ADJUSTABLE 30" 1.5" x 1.5" X 44" 11 GA. GALVANIZED 2"® (TYP) SKIMMER - ANGLE 14 GA. GALVANIZED DUAL MAIN DRAIN WITH STEEL WALL PANEL T 3'-40� VIEW ACROSS CENTERLINE OF HOPPER 7 3.O' STRAINER (VGB SAFETY ACT UNDISTURBED S' (MIN.) APPROVED DRAINS) VINYL LINER I - EARTH _ 2" SAND BOTTOM 3 - --_- SWIMMING POOL I I PANEL STIFFENER TAMPED & ROLLED 42" I I' .� 6" X 30" MIN. 16' 14' 6'--I 4' I CONTINUOUS 2,500 PSI CONCRETE COLLAR FILTERED WATER III_ (ENTIRE PERIMETER) RETURN, NUMBER OF " :a,:•. J POOL SECTION NOZZLES VARIES PER 2 SAND BOTTOM ,r NOT TO SCALE pal SIZEMATERIAL _ 7.5" x 4.5" x 12" MAIN DRAIN PIPING SCHEMATIC I II I I BEARING PLATE NOTE: NOT TO SCALE " " " GENERAL NOTE: DRAWING CONFORMS TO ANSI/APSP-7 SUCTION 2 X 2 X 18 STEEL ANGLE DRIVE ALL MANUFACTURED ITEMS AND CONSTRUCTION SHALL COMPLY WITH THE 2020 ENTRAPMENT AVOIDANCE CODES. 12" LONG REBAR DRIVEN IN STAKE RESIDENTIAL CODE OF NYS,INCLUDING'THE SPECIFICATIONS IN SECTION R326. UNDISTURBED EARTH. USE HOLES 1.5" X 24" X 14 GA. IN PANEL BASE (2.5' MIN. GALVANIZED ANGLE SPACING) PREPARED FOR: WALL SECTION & "A" FRAME DETAIL JOHNSON RESIDENCE NOT TO SCALE 1000 HILLCREST DRIVE NOTES: 1.BACKFILL MATERIAL TO BE SAND,GRAVEL OR OTHER NON-EXPANSIVE MATERIAL. ORI ENT, N.Y. 119 7 2.VERTICAL STIFFENERS TO BE PROVIDED EVERYW ON CENTER. 3.TOP CHANNEL TO BEA 5"WIDE FLANGE. DATE: 17/04/2020 NOTE: �V" HM ENGINEERING, P.C. SCALE: AS SHOWN THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF HM ENGINEERING P.C..UNAUTHORIZED ZpZO SHEET: 1 OF 1 ALTERATIONS OR ADDITIONS TO THESE DOCUMENTS ARE A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE P.O.BOX 914 EAST NORTHPORT,NY 11731 EDUCATION LAW.INFRINGEMENTS WILL BE PROSECUTED. VOID WITHOUT RAISED SEAL AND BLUE SIGNATURE Tel:(516)476-5392 Fax:(631)980-7671 www.hmarnika@optonline.net RESIDENTIAL SWIMMING POOL PLAN