Loading...
HomeMy WebLinkAbout48206-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48206 Date: 8/25/2022 Permission is hereby granted to: Allecia Sandra 300 Harbor Rd Orient, NY 11957 To: install roof-mounted solar panels to existing single-family dwelling as applied for with flood permit. At premises located at: 300 Harbor Rd SCTM # 473889 Sec/Block/Lot# 27.-4-5 Pursuant to application dated 7/13/2022 and approved by the Building Inspector, To expire on 2/24/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Flood Permit $100.00 Total: $300.00 Bbf , Spector TOWN OF SOUTHOLD—BUILDING DEPARTMENT iR Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 " Telephone (631) 765-1802 Fax (631) 765-9502 tt .s://N vw.southoldt wn , ov Date Received BUILDINGAPPLICATION FOR For Office Use Only p 1 1 PERMIT NO. Building Inspector: k-/' IUI- '" Applications and forms must be filled out in their entirety.Y Incomplete p N: Uilip� r,..` _�tl M �.^ applications will not be accepted. Where the Applicant is not the owner,an OP �a i C Owner's Authorization form(Page 2)shall be completed. Date: OWNERS)OF PROPERTY: Name: Sandra Allecia SCTM # 1000-27-4-5 Project Address: 300 Harbor Road, Orient, NY 11957 Phone#: (631) 323-3916 Email• fourgrand4@verizon.net Mailing Address: 300 Harbor Road, Orient, NY 11957 CONTACT PERSON: Name: Tammy Lea/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com DESIGN PROFESSIONAL INFORMATION: Name: William Fisher Mailing Address: 509 Sayville Blvd, Sayville, NY 11782 Phone#: 631-786-4419 Email:bill@fisher-ny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ 0o Will the lot be re-graded? Dyes igNo Will excess fill be removed from premises? ❑Yes iNo 1 PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated, Are there any covenants and restrictions with respect to this property? Dyes *No IF YES, PROVIDE A COPY. ❑ Check BOX After Read Ing: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): ott Maskin IRAuthorized Agent ❑Owner Signature of Applicant: Date: l I as STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this �p day of �A(4 120 ary Public TAMMY LEA Notary Public, gate of New York Registration No,OI LE641 X 842 taw In Subfolia County PROPERTY NERC AUT1"( TICommission Expires November 2,20 (Where the applicant is not the owner) Sandra Alleciaresiding at 300 Harbor Road I OrientScott Maskin do hereby authorize to apply on my be f to the Town o uthold Building Department for approval as described herei *Da 2eOwner's Signature e. Sandra Allecia Print Owner's Name 2 BUILDING DEPARTMENT- Electrical Inspector q; t w TOWN OF SOUTHOLD °" Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro err southoldtownn . ov seand southoldtoLA -ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permitting@sunation.com Address: 171 Remington,Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Sandra Allecia Address: 300 Harbor Road Orient NY 11957 Cross Street: Phone No.: (631) 323-3916 Bldg.Permit#: email: fourgrand4@verizon.net 11 Tax M�aE District: 1000 Section: 27 Block:4 Lot:5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of soler enels - flea on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION JUL11 12V2 1 L Request for Inspection For nAs BUILDING DEPT C + tr'g9�ITC /7-01--kN41 NPO Box 66699,Albany,NY 12206 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A A 753118816km " ox GCG RISK MANAGEMENT INC 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 243630 1 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS' COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,I SURANCE FUND UNDERWRITING VALIDATION NUMBER: 103973329 ql 1111111111000000011000l0Bill 0991403304u1111 II II Form WC-CERT-NOPRINT Version 3(08/29/2019)[WC Po[icy-21606702] U-26.3 64 [00000000000094903304][0001-000@1606702][##2][15762-06][cert_NoP{ERT 1][01-00001] (MMIDDIYYYY) ACb a CERTIFICATE OF LIABILITY INSURANCE NCE 2/11/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT PRODUCER The Horton Group PHONE' FAX 10320 Orland Parkway E-MAIL ° � 708.845 300(0 �Arc,N _ Orland Park IL 60467certi9catcsthorlongrou�cw _ m,.._. RI I _.. RAGE NAIC# .m. a_.INSURE S AFFORDING COVE _,y _ INSURER A:Evanston Insurance Comppgy m 35378 INSURED suNAsoL D1 �� The al Insurance Company _m 35289 SUNation Sol Systems, Inc. INSURER c Axis Surplus l neCo 26620 171 Remington Blvd SURER D:TravelersRonkOnkanaNY 11779 1N ,. of America 25674 INSURER E INSURER F. COVERAGES CERTIFICATE NUMBER: 1814587511 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. �,..-.TYPE- INS ,,,,,,,,,,,,,,,,,, .�� ..,.. --- - .-....._ ..�___ XNTS� URANCE Att]Il POLICY NUMBER APpNO/LCtlOY/YYY M p EXP LIMITS A GENERAL LIABILITY Y Y MKLVlENV103336 2/1112022 2/11/2023 EACH OCCURRENCE S 1.,000,000 COMMERCIAL GENERAL LIABILITY r,ReMII:°�' 7411. ,nrs $300,00000 CLAIMS-MADE L�OCCURMED EXP(Any one person) $10„000 P PERSONAL 8 ADV INJURY S1,000,000 GENERAL AGGREGATE $2,OOD,000 GENLAOGREGAIELIMITAPPLIES ...... a PER. 2,000 D00 PRODUCTS-COMP/OP AGG $ _ POLICY X PRO• LOC2/112022 2/11/2023 $ B AUTOMOBILE LIABILITY Y Y 7018308202 --- LE1 a�IDIN e_k �1.21aDO,p GLIm LX m._ .. � T MI X ANY AUTO BODILY INJUerson)erson) $ ,T RY(Per p ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS .. HIRED AUTOS NON AUTOS acC (NDAMAG _ . _.__.. $ C UMBRELLA LIABX OCCUR Y Y P-001-000795195-01 2/112022 2/11/2023 EACH OCCURRENCE S3,000,000 -� EXCESS LIAR A m CLAIMS-MADE GGREGATE $3,0110 ODO .w..,.,.. DED i ..'RETE... ..,...,,,. ,...- ,..�....,. _.....5 _,,.m,,,... ..mn.. . NTION S WORKERS COMPENSATION WC STATU- OTH. AND EMPLOYERS'LIABILITY YIN TO '1JMi1S,1 JER'”" ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? � N/A E.L.D SEASECIDA EMPLOYEE $ ..... (Mandatory in NH) If yes,describe under E L DISEASE POLICY mnnnY~ — DESCRIPTION OF OPERATIONS below LIMIT $ D Builders Risk Y Y QT-630-2TO10874-TIL-22 2/112022 2/11/2023 500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and auto liability in favor of the stated additional insureds when required by written contract.Excess follows form. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road AUTHORIZED REPRESENTATIVE Southold NY 11971 a I •. ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD YORK 'workers'STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured SUNATION SOLAR SYSTEMS INC 631-737-9404 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 753118816 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"l a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/01/2021 to 09/30/2022 4. Policy provides the following benefits: R] A.Both disability and paid family leave benefits. E] B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the reamed insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 12/1/2021 By Via 4f (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number __516-829-8100 Name and Title Richard WhiteChief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Fonn DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 1111111111111111111111111111111111111111111111111111111111 ,... o.. ........ ....... ..— ��_. ... —....w ...���. a. f i (I it Suffolk County Dept.of l� Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE 1 Name vill SCOTT A MASKIN m Business Name • risduly licensed certifies that the irer is dSUNATION SOLAR SYSTEMS INC he County of suKolk License Number:H44104 Rosalie DraSor Issued: 03/06/2008 f Coannmissworrer Expires: 3/1/2024 r f j I i I i N a iy w. ,�......�.��.w.mm� . ... ......�u.a,__._.. ._.�, _... . eee .n... ..m� ..._..m.............__....w.tiro .. �„�,..... , ..�,� „ .MM.�, � �i f i r Suffolk County Dept.of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN • Business Name This certifies that the bearer is duly licensed SUNATION SOLAR SYSTEMS INC by the County of suffolk License Number:ME-33412 Rosalie Drago Issued: 06/24/2003 Commissioner Expires: 06/01/2023 B� � f 191 1 i f �r 3 r I PLAN KEY ®'UTILITY METER ❑°- -SERVICE DISCONNECT PROPOSED RESIDENTIAL � PV1-0 COVER SHEET -SUPPLY SIDE CONNECTION Al-1 PARTIAL ROOF PLAN ['-AUTOMATIC TRANSFER SWITCH //y,� ^l PHOTOVOLTAIC SYSTEM Al-2 ATTACHMENT SPACING PLAN R-GASMETER Al-4 ROOF ACCESS PLAN M-MAINSERVICEPANEL FRONT OF HOUSE- FACING STREET OR DRIVEWAY ®-SUB PANEL =#= SUNATION SOLAR SYSTEMS NYSERDA Si-1 STRUCTURE [„�-WIRELESS ROUTER ROOF SSC ATS 171 REMINGTON BOULEVARD INSTALLER E1-1 ONE-LINE DIAGRAM ACCESS rt- - RONKONKOMA, NEW YORK 11779 NUMBER 4355 ®-INVERTER E2-1 PV LABELS M-ENPHASE IO COMBINER M P G1-1 PV PHOTOS -PANEL PHOTOVOLTAIC B (EXT)FENCE Allecia Residence _ M-ELECTRIC VEHICLE CHARGER E] Al 300 Harbor Road, Orient, NY 11957 -ENPHASE ENVOY _ms_ N-SENSE CONSUMPTION MONITOR Drawn By: S. Beattie - 07/07/2022 ©-AC DISCONNECT 101 Ff-TESLA GATEWAY =_ -TESLA POWERWALL '' Z C If-ENPHASE IO SYSTEM CONTROLLER �' O \�\\Om �f� �O FISHER ENGINEERING SERVICES, P.C. �-ENPHASE IO LOAD CONTROLLER 'm F, c�. S� 4 509 Sayville Boulevard �-ENPHASE IO IO BATTERY Z h—( Y. ' � > Sayville, New York, 11782 �.' LU II ®-ENPHASE 103 BATTERY D n JlrilA Licensee No. 074659 0-GENERATION PANEL ' //0 97•.^5Dj ;? (631)-786-4419 ©-BACKED UP LOADS CENTERBill@Fisher-NY.com Bill@Fisher-NY.com J 1VKV I E) -VENT PIPE 1 •^-EXTERIOR LOCATION - - -- - -- -- - - ------—--- t -1 ST FLOOR LOCATION Building Review Note -BASEMENT LOCATION Town building examiner has received the enclosed document for minimum acceptable GARAGELOCATION plan submittal requirements of the town as specified in the building and/or Residential Code of the State of New York. This review does not guarantee compliance with that ❑ code. that responsibility is guaranteed under the seal and signature of the New York PROPOSED PV SYSTEMState licensed design professional of record. That seal and signature has been ROOF interpreted as an attestation that,to the best of the licensee's belief and information Module Type/Qt 51 REC395AA BLACK ACCESS the work in this document is: YP Y ( ) Accurate • Conforms with governing codes applicable at the time of submission Module Dimension: 71.69”x 40"x 1.18" (24)PROPOSED PV MODULES (27)PROPOSED PV MODULES Conforms with reasonable standards of practice and with view to the safeguarding of life,health,property and public welfare is the responsibility of the Module Weight/PSF: 45 lbs/2.3 PSF licensee. Micro Inverter: (51) Enphase IQBPLUS-72-2-US System DC Rating: 20.145 kW Structural Statement • The existing structure is adequate to support the new loads imposed by the Estimated AC Production: 18,807 kWh/yr photovoltaic module system including uplift and shear. The existing rafter sizes Production Source: Aurora and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof access points,access pathways and ventilation systems shall be II �,R -- -- -- — —--- --- -- --- -- - --- -- provided where necessary. An in depth description of each applicable code Ul I AREA Ra SERVED FOR AH�i' reference and exception for any codes is depicted on the PV-1 plate of this drawing package. 2. Roof shall have no more than a single layer of roof covering in addition to the JUL2022 solar equipment. I I L C L 3. Installation of solar equipment shall be flush-mounted,parallel to and no more _3Dthan 6-inches above the surface of the roof. (V4. Weight of the installed system shall not exceed more than 5-psf BUILDING DEPT. 5. Any plumbing vents are not to be cut or covered for solar equipment installation. TOWN OF S0UTH1L."LID Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN inspection. SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PV1 =0 COVER PAGE JOB# 22493 REVISION # N/A SUNATI0N ENERGY REVISED BY N/A CIRCUIT 2 of NES �P,•��o m �•Fs t- R.R.-2" 3' @ 16"O.C. _ 7 aaas • . . . . . � _ 1; ;� ",I"." 'I" .. • sr pia Bio"Dv CIRCUIT 4 CIRCUIT 3 • • • 6 • 6660 • • • • 10'-10" • • El • FISHER ENGINEERING • • • • SERVICES,P.C. t I.' • • 509 Sayville Boulevard Sayville,New York,11782 • • • • • 0 0 • • Licensee No.074659 ® • 000 © I' 1."' • • Bi1(63Fi herb-441 om • • • @ s • R.R.-3.5"X 6" SUNATION • @ 24"O.C. • T• ENERGY STRUCTURE CHANGE • • SUNT tRemington Blvd.Systemsion Solar • Ronkonkoma,New York 11779 • • I �' • (631)-750-9454 GUTTER 33'-5" 14L 4 RIDGE 33'-4%2° GUTTER ERDA INSTALLER 4355 11 • INSTALLER I. 1 .• • NUMBER • JOB NUMBER 22493 • : r N •' O N W O Z } t` ❑ ' �•� �" -'�" CIRCUIT 1 0 0 I'' I,• i ,/ � o 3 Z roC11 m -23--1y2" 23'-2" Q `p -�,\ � m ROOF 2 ROOF AREA RIDGE CAPPING PHOTOVOLTAIC MODULE ROOF 1 `� = 3 (TYP.) (TYP.) c° m C Attachment Spacing: Portrait Attachment Spacing: Landscape Roof# Roof Description Modules Azimuth Tilt Pitch Interior Edge Corner' Interior Edge Corner 1 Southeast Roof 27 1150 210 5.6/12 48" 32" 16" 64" 64" 48" 2 Southeast Roof 24 1150 210 5.6/12 48" 32" 16" 64" 64" 4811 3/16"= 1'-0" Al = 1 PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS OF /V (NY) R324.6 Roof access and pathways. Roof access, pathways and setback requirements shall be provided in accordance with Sections �L��0 R324.61 through R324.6.2.1. Access and minimum spacing shall be required to provide emergency access to the roof, to provide pathways to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. ,o-'0.0716S'� � E Exceptions: 1. Detached,garages, par structures, including but not limited to FRONT OF HOUSE - FACING STREET OR DRIVEWAY FISHER ENGINEERING SERVICES,P.C. detached garages, parking shade structures, carports, solar 509 Sayville Boulevard trellises and similar structures, shall not be required to provide Sayville,New York,11782 roof access. Licensee No.074659 2. Roof access, pathways and setbacks need to be provided ROOF SSC ATS O (631)-786-4419 where the building official has determined that rooftop ACCESS �— U M Bill@Fisher-NY.com operations will not be employed. -36"- 3. These requirements shall not apply to roofs with slopes of two M P SUNdaTI®N units vertical in 12 units horizontal (17-percent slope)or less rk ro� ) _ FENCE ENERGY [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate S B (EXT) SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches El ( == 171 Remington Blvd. (914 mm) wide, shall be provided on all buildings. Not fewer than one Ronkonkoma,New York 11779 (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. ro� DSC For each roof plane with a photovoltaic array, a pathway not less than 36 inches (914 mm) wide shall be provided from the lowest roof edge NYSERDA 4355 INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. IQ Pathways shall be over areas capable of supporting fire fighters j JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal obstructions such as vent pipes, conduit, or mechanical equipment. Z /� 9 Pathways on opposing roof slopes shall not be located along the same -_O `I'9 00 plane as the truss, rafter, or other such framing system that supports = F= the pathway. J. m , Exception: z z _I W . 1. Access pathways shall not be required on roof slopes containing r _> photovoltaic modules, panels, or an array where the opposing � or adjacent roof slope is an access roof. M N � ' r Z r N Access Roof-A roof surface that: 0 z Q c c o 1. Can be accessed from the ground by the fire service. cc 2. Is capable of providing fire service access to the ridge or peak i p m O of an opposing or adjacent roof surface that contains LL °C m photovoltaic modules,panels,or an array. Z 3. Is relatively free of vents,skylights,conduits, mechanical w — o >, Q .n m equipment and other such obstructions. 4 N 4. Does not contain photovoltaic modules, panels or an array, or is = m a single ridge roof where the maximum edge to edge width of o 0 the photovoltaic panel system does not exceed 33 percent of the ridge length. [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be ROOF located less than 18 inches(457 mm)from a horizontal ridge. ACCESS -36 - [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion (24) PROPOSED PV MODULES (27) PROPOSED PV MODULES of the roof that is below and emergency escape and rescue opening. A pathway not less than 36 inches (914 mm)wide shall be provided to the emergency escape and rescue opening. 3/16" = 1'-0" A1 =4 ROOF ACCESS PLAN of NES Typical Attachment Method ;�;�°m G•Fsh _ - �/°•074659!��C�� SNAP'N'RACK ULTRA RAIL �L-FOOT AND RAIL ASSEMBLY FISHER ENGINEERING SERVICES,P.C. RIDGE--� RIDGE 509 Sayville Boulevard Sayville,New York,11782 PHOTOVOLTAIC 23'-1.5" PHOTOVOLTAIC 0'-011 Licensee No.074659 MODULE MODULE (631)-786-4419 Bill@Fisher-NY.com 3/4"MODULE SPACING (2)S.S.304 5.OMM X 60MM �wT3/4"MODULE SPACING WOOD SCREW FASTENER I ,\1 Y�1 BETWEEN ROWS AND BETWEEN ROWS AND SUNAl®w' ` 1=1VE COLUMNS(TYP.) COLUMNS(TYP.) RT-MINI ROOF RGY ' " RAFTER / RAFTER ATTACHMENT SUNation Solar Systems 2 X 6 /16 O.C. 3.5' X 6 /24 O.C. MOUNTED TO 171 Remington Blvd. RAIL RAIL RAFTER Ronkonkoma,New York 11779 HEADER�� (631)-750-9454 Ox E( DOWN TO (1)LAYER ASPHALT o NYSERDA 4355 POSTED DOWN TO SHINGLE(TYP.) EXISTING INTERIOR BEARING WALLS NUMBER INSTALLER AQ BEARING WALL �/ JOB NUMBER 22493 SOFFIT SOFFR EXTERIOR EXTERIOR ACTUALSPAN WALL ACTUAL SPAN WALL PLYWOOD DECKING 10'-11" (TYP.) 18'-2" 18'-2" WOOD FRAMING (TYP.) PARTIAL ROOF SECTION (TYP.)- ROOF"1&2" PARTIAL ROOF SECTION (TYP.)- ROOF"1&2" ATTACHMENT TYPE APPLIED TO-ROOF"TYP" SCALE: N.T.S. SCALE: N.T.S. LO N O r N Z a) Z SOLAR MODULE FRAME O NOTE:3/4"SPACING BETWEEN 0 0 0 ° AND COLUMNS ULE ROWS Q -0 .lv Roof# Rafter Size/Spacing Max Span Material Layers Sheathing o e T ¢ O 1 *VARIES* 101-11" Composite Shingles 1 Plywood °o OCJ"I �O O� 55 HEIGHT ADJUSTABLE LL -� 0) L-FOOT"P.) Z M 2 *VARIES* 101-1111 Composite Shingles 1 Plywood END CLAMP W 0 (TYP.) Q >+ ° O O SNAP'N'RACK o� O O OOO O 6.0" ULTRA RAIL i (TYP.) (13 C o coo 0 1 _ HEIGHT OFF OF O ROOF SURFACE O C) ('7 RT MINI 2 (TYP.) Typical Module PEST WRAP CUT Side Profile AWAY FOR CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE ICE BARRIER SEISMIC DESIGN WINTER DESIGN MEAN ANNUAL GROUND SNOW SPEED(MPH.) TOPOGRAPHIC SPECIAL WIND ZONE WIND BORNE DEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX TEMPERATURE LOAD EFFECTS ZONE - 20 PSF 140 B NO 2 B SEVERE 3'-0" MODERATE TO 15 DEG N/A SEE PLANS 599 51 HEAVY EXAMINER STRUCTURE F NFIy ,07465a G FISHER ENGINEERING SERVICES,P.C. Enphase A/C Branch Circuit(typ.) 509 Sayville Boulevard Sayville,New York,11782 1201240v Licensee No.074659 Utility Service (631)-786-4419 Enphase Microinverter(typ.) Bill@Fisher-NY.com COMBINER SUPPLY-SIDE SUNATION Module J-Box(typ.) PANEL CONNECTION EXISTING ENERGY FGENERATOR • SUNation Solar Systems 171 Remington Blvd. PV Module(typ.) Ronkonkoma,New York 11779 (631)-750-9454 EGC Attached To Rail(typ.) 200A 1 200A 1 J J NYSERDA 4355 b MAIN MAIN INSTALLER ENPHASE GATEWAY s NUMBER (No loads.Eo t.rNg only) — Aut uratic s _ JOB NUMBER 2P20A 2P15A Circuit#1 sron..GA. y CONDUIT AND CONDUCTOR SCHEDULE ENPHASE BRANCH CIRCUIT#1 2P20A 22493 ENPHASE BRANCH CIRCUIT#2 N Circuit#2 TAG CONDUCTOR CONDUIT RUN zazoA 80A s ENPHASE BRANCH CIRCUIT#3 Circuit#3 TYPE GAUGE QUANTITY TYPE SIZE LENGTH 2P2oA MAIN s ENPHASE BRANCH CIRCUIT#4 1 Enphase Q-Cable 12 8 N/A N/A 15' Y' Y clrouit#a 2 Type NM 10 8 N/A N/A 30' EGC G G ' G -1 MAIN 1 ,Z 3 `3i ENPHASE 1 A/C TRANSFER SERVICE HWN 2 10 8 PVC SCH.80 1.25" 15' IQ COMBINER DISCONNECT SWITCH PANEL GC 8 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR SERVICE RATED 4 HWN-2 4 3 PVC SCH.80 1.25" 10' 4 ENCLOSURE ;6� MIN.100A GC 8 1 PVC SCH.80 1.25" 10' MIN.22k AIC LO N 5 HWN-2 3 3 PVC SCH.80 1.25" 10' — Np 6 GC 6 1 N/A N/A 10' BUILDING r N GROUNDING ELECTRODE Z Z C:) O v r1_ C:) CD O 0) OCz LL _ Z co CO Circuit# PV Module Qty- Micro-Inverter Qty. Maximum AC Operating Current W12�0 Uj 1 REC395AA BLACK 13 Enphase IQ8PLUS-72-2-US 13 15.73 A U) Q 0 m 2 REC395AA BLACK 13 Enphase IQ8PLUS-72-2-US 13 15.73 A 2� En phase IQ8PLUS-72-2-US 3 REC395AA BLACK 13 p 13 15.73 A o p 4 REC395AA BLACK 12 Enphase IQ8PLUS-72-2-US 12 14.52 A Maximum AC Operating Current (Total) 61.71 A E1 = 1 ONE-LINE DIAGRAM LABEL LOCATION: LABEL LOCATION: OF A CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ ServiI Disconnect MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE ; CEILINGS/FLOORS OR MORE THAN 10'. DISCONNECT IF APPLICABLE. r .® . ® . NEC 2017 690.31(G)(3) of NEC 2017 705.10 �4 y LABEL LOCATION: • • Disconnect •• SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Located next to Meter Pan FISHER ENGINEERING • e• - CURRENT VALUES ON DISCONNECT LABEL. SERVICES,P.C. 509 Sayville Boulevard NEC 2017 690.541 NEC 2017 690.13(B) Sayville,New York,11782 NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO Licensee No.074659 THE BUILDING MAIN SERVICE DISCONNECT. (631)-786-4419 Bill@Fisher-NY.com Service Disconnect c� � t :. SUNATION ENERGY ELECTRIC SHOCK HAZARD SUNation Solar Systems 171 Remington Blvd. DO NOT TOUCH TERMINALS - New TERMINALS ON BOTH THE LINE AND • - Ronkon(631)-750-9454k 1179 LOAD SIDES MAY BE ENERGIZED ServicePanelNYSERDA 4355 IN THE OPEN POSITION Located . INSTALLER PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE 3 fir' _ _ NUMBER WHENEVER THEY ARE EXPOED TO SUNLIGHT EQUIPPED i . ®A. ID.'� JOB NUMBER - -- - D• 22493 LO C\I r N z � z 0 O }; o 'i O OLL N Z Eg O m W ID M C/) F _ C0 Q 5 m 2 � 0 E2= 1 PV LABELS I oF ' moi'i�_=:-- _ _ _ =t_�^j",'t. • 2 `—�>.' _ • FISHER ENGINEERING �`� y�'� !%' —_ ' 1 j •� SERVICES,P.C. '509 Sayville Boulevard „ `(/ t_ _1_�__•_`` `. - �,,, - :;� � Sayville,New York,11782 - - M Licensee No.074659 (631)-786-4419 Bill@Fisher-NY.com • ^rvR�t SUNATION ENERGY( SUNation Solar Systems ,• _ " ,.2: 171 Remington Blvd. Ronkonkoma,New York 11779 }. :j ^x]�'= -- -"_ _ '. - - - -_�fir'. _T•-11 '":ar,°'.S,'.' nl" (631)-750-9454 NYSERDA .:rt.:> ..s:',. _ -".'• — °^`_�` -_ _ �' ::�.;� INSTALLER q,3 NUMBER 55 JOB NUMBER .ter,' :-;I '„ _ ,._ - r-�t-' '- .t �'• ' a'ti; 'o o[l: - � 22493 ARRAY LOCATION(S) ARRAY LOCATION(S) SATELLITE IMAGE VIA GROUND VIA ROOF r N v o cc Uj IL) CZ co m W rf Cf) t'8 F 1`•` ' Y alF SrWmYaEnLuion '1 Cz _ �. _ OYRYarouES W4GE _ 03 co 1 I I 1 i SOUTH VIEW PROPOSED PV EQUIPMENT EXISTING UTILITY METER VIA ROOF LOCATION AND MDP G 1 = I PV PHOTOS Fisher Engineering Services, P.C. g g 509 Sayville Blvd • Sayville •New York 11782 Phone: (631) 786-4419 July 7, 2022 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Allecia Residence-300 Harbor Road, Orient,NY 11957 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system(photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2020-Residential Code of New York State (2020 RCNYS), Long Island Unified Solar Permit Initiative (LIUSPI), 2017 National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting,the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 140 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters 2"x6" on 16c.c. & 3.5"x 6" on 24"c.c. with an actual span of 10'-11", with, plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, of NE`y r William G. Fisher, P.E. arc• O,P Licensed Professional Engineer a1, r� Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections . REE AL'PHCX PURE 5ERI PRDDUCT SPECIFIC_ ATION 400wp 20.3 'Y-F�T 2 9 IN r�.-aaOD \I ,7 � o REC PRODUCT P A . S\\OLAR'S MOST TRUSTED 1821±2.5[71.7±0.11 28[1.11 901[35.51 460[18.11 CERTIFICATIONS b IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) ...................................................................................................................._..................__...... El + 15014001:2004,150 9001:2015,OHSAS18001:2007,IEC 62941 1100[43.31 UVE c - Intertek 6.0±0.2 [0.24±0.011 ^ WARRANTY r s M - ® N Standard, REC ProTrust o * Installed by an REC Certified __.____......_._.._._............_......._..._................................. o Solar Professional No Yes Yes 0 11±0.2 a ......-.....--............._........._..................................................._;.-.._...---- - [0.43±0.011 System Size All s25 kW 25-500 kW ..................................................................................._------'-=-'--._.._...__._...._...---._............_...... Product Warranty(yrs) 20 25 25 Power Warranty(yrs) 25 25 25 n^ 20.5±0.5 _............-.........._................_.......... -...----�-- [0.8±0.021 1200[47.21 - Labor Warranty(yrs) 0 25 10 _...........__.........- ...... -o........_. -- - o ._-• Power inYear1 98% 98/0o 98/0 . -- - --- .- ..................._...................................................... --- -;._..__........_.............._..............._..._.. _t Annual Degradation 0.25% 025% 0.25% T i 671±3[26.4±0.121 ..................................._......._.........__.........-�-----_-.._...-�-------._....._._._�_ L .-45[1.81 22.5[0.91 - Power in Year 25 92% i 92% 92% 130[1.21 See warranty documents for details.Conditions apply Measurements in mm[in] GENERAL DATA q - - MAXIMUM RATINGS 132half-cut REC heterojunction cells St6ubliMC4PV-KBT4/KST4,12AWG(4mm2) Operational temperature: -40...+185°F(-40...+85°C) . ........................................................................................................................... Celltype: with lead-free,gaplesstechnology Connectors: in accordance with IEC 62852 Maximumsystemvoltage: 1000V 6 strings of 22 cells in series I P68 only when connected ............................................. . .................................................... . ................................................... ................................................................................................................ Maximum test load(front): +7000Pa(146lbs/sgft). . 0.13in(3.2mm)solarglasswith l2AWG(4mm2)PVwire,43+47in(1.1+12m) .............................................................................................................................. Glass: Cable: anti-reflection surface treatment accordancewithENS0618 Maximum test load(rear): -4000 Pa(83.5 lbs/sq ft)* ................................................................................................................ ................................................................................................................ Backsheet: Highly resistant polymer(black) Dimensions: 71.7x40xl.2in(1821x1016x30mm) Max series fuse rating: .25A u ................................................................................................................ ................................................................................................................ Max reverse current: 25A 'o Frame: Anodized aluminum(black) Weight: 45lbs(20.5kg) "See installation manual for mounting instructions. ....................................................... ................................................... ................................................................................................................ Design load-Test load/1.5(safety factor) 3-part,3 bypass diodes,IP68 rated Junction box: inaccordancewithlEC62790 Origin: Made in Singapore L ELECTRICAL DATA Product Code':RECxxxAA Pure TEMPERATURE RATINGS' Power Output-PMAx(Wp) 385 390 395 400 405 Nominal Module Operating Temperature: 44°C(±2°C) ME ...................................... ............................................................,.......................................................................................................... Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+ / Temperature coefficient ofPMAx: -0.26%/'C .......................... ........................................................................................................................... o Nominal PowerVoltage-VMPP(V) 41.2 41.5 41.8 42.1 42.4 Temperature coefficient ofVoc: -0.24%rr_ ......................................................................................................................................................................................................................... ........................................................................................................._............... u Nominal Power Current-IMpp(A) 9.35 9.40 9.45 9.51 9.56 Temperature coefficient oflsc: 0.04%/°C a t. ..................................................................................................................................................................................................................................... to to Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 'The temperature coefficients stated are l[nearvalues ..........-..............................................................................._........................................................................................................................................ .. Short Circuit Current-Isc(A) 10.10 10.15 10.20 10.25 10.30 ..............................................................................._........................................................................................................................................... ......... Power Density(W/sq ft) 19.3 19.6 19.8 20.1 20.3 ` -'T LOWLIGHT BEHAVIOUR ...................................................... .......... ........................................................................................................................................................... -- - - - PanelEfficiency(%) 20.8 21.1 21.3 21.6 21.9 Typical low irradiance performance of module at STC: N R1 O Power Output-PMAx(Wp) 293 297 301 305 309 a ..................... F Nominal Power Voltage-VMPP(V) 38.8 39.1 39.4 39.7 40.0 .m t .......... ..................... ............................... ........................................................................................................................................................... m -- o g Nominal Power Current-IMpp(A) 7.55 7.59 7.63 7.68 7.72 w --------------------------------------------- N Z .................................................................... ............................................................................................................................................................... W Ln Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46.1 ---------'......-- _-"---- o Short Circuit Current-Isc(A) 8.16 8.20 8.24 8.28 8.32 Imadiance(W7.2) w Values at standard test conditions(STC:air mass AM 15,irradiance10.75 W/sq ft 0000 W/m2),temperature 777(25°C),based on a production spread with a tolerance of Pte,Vo,&I.±3%within one watt class.Nominal module operating temperature(NMOT:air mass AM I.S.irradiance 800 W/m',temperature 687(20°C),windspeed 33 ft/s 0 m/s).*Where xxx indicates the nominal power class(P.)at STC above. Founded in 1996,REC Group is an international pioneering solar energy n company dedicated to empowering consumers with clean,affordable 'tip R solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar www.recgroup.com panels it manufactures. Headquartered in Norway with operational 0 'Di headquarters in Singapore,REC also has regional hubs in North America, Europe,and Asia-Pacific. 0 ENPHASE. m hL IQ8 and I08+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling lir-------�--•- - -- . Enphase I' High productivity and reliability • Produce power even when the llyear limited grid is down My i' More than one million cumulative Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules agoMicrogrid-forming CERTIFIED Complies with the latest advanced grid support Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements I Q8S P-DS-0002-01-EN-U 5-2021-10-19 n b IQ8 and IQ8+ Microinverters INPUT DATA[DC) 108-60-2-US ,:. Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currentz(module Iscj A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA(ACI 108-60-2-US JOSPLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ85P-DS-0002-01-EN-US-2021-10-19 r'r� , SERIES 100 FLASH4ED- .1L FOIOT- K[ The SnapNrack line of solar mounting �` � n i'`�^-a'yvl:SS'f'c• �'� systems is designed to reduce total rq -'y` ;j �` ' y'�.�tL � zPC:ti^ys`'n'�'i"�3,s.;'vKL''�. �&• y'�:y;•,:"'�Yj4:. y. installation costs. The system features x -✓ 4 technical innovations proven on more µ than 20OMW of solar projects to simplify installation and reduce costs. � . _ . :{ �. �.. t'-���3��.y.`•,M�sf.�^''�_C.=-fir" Flashed L Foot Simplified T: SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal overA" V ;��g •�:: -'ter- �' ;r. � the life of the system. The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • www.snapnrack.com/contact No Cutting of shingles SnapNrack- Patent Pending pW NW)URiTnia s b)MO I ; Flashed L Foot Kit Assembled(1"spacer sold separately) Flashed L Foot Kit Parts(1"spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions ,SNAPNRACK CHANNEL NUT t i I ISNAPNRACK 92 DEGREE L•FOOT,CLEAR F5116-IS FLANGE NUT , --S/I&18 X IIN BOLT WITH SPLIT LACK WASHER -SNAPNRACK COMPOSITION FLASHING I � 0 3.13 \"-SNAPNRACK L-FOOT BASE —4- SnapNrack Flashed L Foot Data Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum ,Weight 0.16 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship SnapNrack- (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack Pv Mounting System.All rights reserved. SERIES 100 ROOF MOUNT SnapNragk Solar • • Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 3S0 MW of solar _- installations. ' Pitched Roof Array prt.; P s Simplified The SnapNrack Series 100 UL Roof p oo Mount System V _,..f�'x. .��`•''.,. � �; is an efficient, visually appealing, photovoltaic(PV) module installation system. Series 100 UL is Listed I-- - - -- -- - =- ---- - - - -to the UL Standard 2703 for Bonding, meaning that I all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware. The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 i 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide ! Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. . • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules I for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) U • Class A Fire Rating Type 1 and 2 modules O LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Split-Lock Washer Bolt with Split- Splice Insert Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack `�� Bonding Splice _ Clamp Top Mid Clamp Base SnapNrack SnapNrack Bonding SnapNrack Bonding Adjustable End Bonding Stainless Nut Clamp Bottom Channel Nut Stainless Hardware with Bolt with SnapNrack Bonding Split-Lock Washers Split Lock SnapNrack Bonding Washer Adjustable End ClampL SnapNrack BondingMid Clamp Standard Rail Splice SnapNrackto-s AWG :-,,,,Channel Ground Lug Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF • MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt E .� with Flat Washer IF IF IF IF IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding r Standoff Clamp Assembly SnapNrack Serrated Stainless�� SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack of 92 Degree Flange Mill Finish L Foot Bolt Standoff o0 Y y SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) a SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding J SnapNrack Bonding SnapNrack Metal Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack • • UL Technical Data Patent Pending Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. &Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) SnapNrack- Solar Mounting Solutions (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved.