Loading...
HomeMy WebLinkAbout48202-Z at �*M TOWN OF SOUTHOLD Af BUILDING DEPARTMENT /10 TOWN CLERK'S OFFICE SOUTHOLD, NY '11,94ea -oa,�, P BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48202 Date: 8/24/2022 Permission is hereby granted to: Roman, Mary PO BOX 655 Orient, NY 11957 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 740 Po uatuck Ln, Orient SCTM # 473889 Sec/Block/Lot# 27.-3-4.5 Pursuant to application dated 7/13/2022 and approved by the Building Inspector. To expire on 2/23/2024. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector � d°` SFi�ly M TOWN OF SOUTHOLD—BUILDING DEPARTMENT '., k � Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 lett as:Hwww,.soutlaoldtownn_ , ov Date Received APPLICATIONI For Office Use Onlyu PERMIT NO. �' a, Building Inspector; F � a Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an BUfLINC EP0 TOWN OF SOUTB 0.0 Owners Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: Ellen Birenbaum ]�scTM# 1000-27-3-4.5 Project Address:740 Poquatuck Lane, Orient, NY 11957 Phone#:(917) 232-1422 Email:ebirenba@gmail.com Mailing Address:P.O. Box 655, Orient, NY 11957 CONTACT PERSON: Name: Tammy Lea/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com DESIGN PROFESSIONAL INFORMATION: Name:Michael Dunn Mailing Address:256A Orinoco Drive, Brightwaters, NY 11718 �Pho n-e#-631-665-9120 Email:glenn@grahamassociatesny.com CONTRACTOR INFORMATION: Name:Scott Maskin/Sunation Solar Systems Mailing Address: 171 Remington Blvd., Ronkonkoma, NY 11779 Phone#: 631-750-9454 Email:permitting@sunation.com DESCRIPTION OF PROPOSED CONSTRUCTION [:]NewStructure ❑Addition i@Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other s, 3a SDb-b D Will the lot be re-graded? ❑Yes W No Will excess fill be removed from premises? ❑Yes 5RNo 1 PROPERTY INFORMATION Existing use of property: Residential Intended use of property: Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes RNo IF YES, PROVIDE A COPY. ❑ Check Box AfterReading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Sc Maskin ®Authorized Agent ❑Owner Signature of Applicant: Date: -�(71az), STATE OF NEW YORK) SS: COUNTY OF Suffolk Scott Maskin being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of J�d, 20- 1�; tary Public TAMMY LEA Notary Public,State of New York R 'slretion No.OIL 410842 d ualifoed in Suffolk County PROPERTY OWNER AUTHORIZATION Cornmission Expires Navember,ZM2o (Where the applicant is not the owner) f 2 740 Poquatuck Lane I, �l eh 13,re;, b-g residing at Orient Scott Maskin do hereby authorize to apply on my behalf t he wn o Southold Building Department for approval as described herein). Owner's Signature D to Ellen Birenbaum Print Owner's Name 2 � .' BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro err sautholdtown ov sea southoldtownn . ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: SUNation Solar Systems, Inc Name: Scott Maskin License No.: 33412-ME email: permitting@sunation.com Address: 171 Remington Blvd. Ronkonkoma NY 11779 Phone No.: 631-750-9454 JOB SITE INFORMATION (All Information Required) Name: Ellen Birenbaum Address: 740 Po uatuck Lane, Orient, NY 11957 Cross Street. Phone No.: (917) 232-1422 Bldg.Permit#: email: ebirenba@gmail.com Tax Map District: 1000 Section: 27 Block: 3 Lot: 4.5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Installation of solar panels - flat on roof Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On (Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect-Service Reconnected - Underground - Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION DO Request for Inspection Form.xls BUILDING DEP i � TOWN OF=;()IJTJJ 0 10091-1\111\1- PO Box 66699,Albany,NY 12206 New York State insuNYSlrance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A A 753118816R GCG RISK MANAGEMENT INC 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER I CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 243630 01/01/2022 TO 01/01/2023 12/14/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND 4 DIRECTOR,ISURANE FUND UNDERWRITING VALIDATION NUMBER: 103973329 11011111111111110 pp'I III 1 Hili Bili Bili Bill Hu1Hu1 Bili Bili Bili 111111111 m11 oiu 11111 NN A 0000000000099403304 Farm WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-216067021 U-26.3 64 [00000000000094903304][0001-000021606702][##2][15782-06][CerLNoPCERT_1][01-00001] ' /Y DATE(MMIDDYYY) , ► R" CERTIFICATE OF LIABILITY INSURANCE 2/11/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must be endorsed. if SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CT NAME. The Horton GroupPHO 708-846-3000 FAX 10320 Orland Paray _ Orland Park IL 60467 ADDRESS: certificates thehorlorlgm ial rz INSIi!1R ,S,A„FFORDIN,RROVERAGE..mm INSURER A;Evanston Insurance Company............. .. 35378 ....._ ......................._-.mm....m.m...m...,...,,,.... O_...,. IMS-m.mm.mm..�,.,,.,m_ INSURED SUNASOL-01 SUNation Solar Systems, Inc. INSURER uRER a:Axis Surpluswlnsura w ”'Comp fir .26620 _ B:The Continental Insurance an 352 171 Remington Blvd P �nceww - Ronkonkoma NY 11779 INSURER 0:Travelers Pro a &wC sualty Company of America 25674, INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:1814587511 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES,LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, IfVSR ..... ...W...... ..... ... ......m,AbbL?U6 Y'. .... _-.-.,..._..________ POd�'ICY Exp .... LT TYPE OF INSURANCE POLICY NUMBER MM/DD/YYYY MMP.: LIMITS A GENERAL LABILITY Y Y MKLVlENV103336 2/11/2022 2/11/2023 EACH OCCURRENCE ..... S 1,000,0 0 0 SMIEEaourac $300000X COMMERCIAL GENERAL ABILITY CLAIMS-MADE OCCUR MED EXP(Any one person) $10,000 . .. .. .....,. .... ...... ..e,,.,.n..............�,,, ......._w ..PRSO.NA & INJURYAV $1000000 .... .... mm, ........ GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000,000 POLICYFx_1 PRO. LOC $ B AUTOMOBILE LIABILITY Y Y 7018308202 2/1112022 2/11/2023 COMBINED SINGLE LIMIT i anS). $-t 0 949 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY ............ ............. BO..D...I.L......N..J..U.mmRY(Per.ac ci dent) $ AUTOS AUTOS NON-OWNED ORDAMA .. $HIREDAUTOS AUTOS LepTe. C UMBRELLA LIAR X OCCUR Y Y P-001-000795195-01 2/11/2022 2/1112023 EACH OCCURRENCE ___.S3,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE S3,000,00.0 ..... ....... "DED.,wm .— RETENTION$ $ WORKERS COMPENSATION WC STATU OTH AND EMPLOYERS'LIABILITY Y/N 1ORKLIMITS.. . .... F.R I........._....... ANY OFFICERIMEMBER EXCLUDED NIA ECUTIVE E L EACH ACCIDENT....... ... p,,....,m.,.-m.,.---m.,.... ,. (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ DESCRIPTION OF OPERATIONS below E L DISEASE If y describe under SE POLICY LIMIT $ D Builders Risk Y Y QT-630-2T010874-TIL-22 2/11/2022 2/1112023 500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Additional Named Insureds:SUNation Service Inc;SUNation Electric Inc;SUNation Commercial Inc;SUNation Cares Inc Additional Insured on a primary and non-contributory basis with respect to general liability and auto liability coverage when required by written contract.Waiver of subrogation applies to general liability and auto liability in favor of the stated additional insureds when required by written contract.Excess follows form. Town of Southold is included as an additional insured as required by written contract and the CG 2012(State,Governmental agency,or Political subdivision permits or authorization)is included on the policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Main Road Southold NY 11 971 AUTHORIZED REPRESENTATIVE ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD YORK Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured SUNATION SOLAR SYSTEMS INC 631-737-9404 171 REMINGTON BOULEVARD RONKONKOMA,NY 11779 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 753118816 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b. Policy Number of Entity Listed in Box"1a" PO Box 1179 DBL631187 Southold, NY 11971 3c.Policy effective period 10/01/2021 to 09/30/2022 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: © A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 12/1/2021 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) III I111111I Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name SCOTT A MASKIN Business Name 5 certMes that the wear is duly licensed SUNATION SOLAR SYSTEMS INC .he County of sorolk License Number:H-44104 Rosalie Ora go Issued: 03/06/2008 Expires: 3/11/2024 Suffolk County Dept.of Labor,Licensing&Consumer Affairs yw MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN • Business Name This certifies that the bearer Is duty Licensed Sl1NATION SOLAR SYSTEMS INC by the Cownty of sutte9k License Number:ME-33412 I Rosalie Draw Issued: 06/2412003 arrurnissbentr Expires: 0610112023 i 41 i r, i i s r !4 0 k it I i i i) r i t I ® UTILITY METER PLAN KEY Q-SERVICE DISCONNECT PROPOSED RESIDENTIAL PV1-0 COVER SHEET ®-SUPPLY SIDE CONNECTION Al-1 PARTIAL ROOF PLAN o-AUTOMATIC®- TRANSFFASWTCH -GAS METE � PHOTOVOLTAIC SYSTEM A1-2 ATTACHMENT SPACING PLAN (� ° A1-4 ROOF ACCESS PLAN MAIN SERVICE PANEL ERDA S1-1 STRUCTURE ® SUB PANEL SUNATION SOLAR SYSTEMS ULEVAR INSTALLER 4355 �-WIRELESS ROUTER 171 REMINGTON BOULEVARD INSTALLER E1-1 ONE-LINE DIAGRAM RONKONKOMA,NEW YORK 11779 NUMBER ®-INVERTER /��jy�' `J E2-1 PV LABELS -ENPHASE IOCOMBINER O /A y1/w{)� Birenbaum Residence G1-1 PV PHOTOS PANEL PHOTOVOLTAIC VVV�"' -• 740 POgUaturk Lane, Orient, NY 11957 -ELECTRIC VEHICLE CHARGER ®•ENPHASE ENVOY c �+ !] -SENSE CONSUMPTION MONITOR Drawn B off/• S. Beattie-07/06/2022 ®-AC DISCONNECT Q•TESLA GATEWAY MTS R D ARCy I ®-TESLA POWERWALL Q SUB(g) r.! !L�• /���T�/�• -ENPHASE 10 SYSTEM CONTROLLER T �P` J D�•/� `/'� ®-ENPHASE IO LOAD CONTROLLER w G$ 1.� -ENPHASE 10 10 BATTERY C7 -1B"-VENTILATION ®-ENPHASE 10 3 BATTERY Z18 is- < — d ®-GENERATION PANEL LL SY" - y}: ©-BACKED UP LOADS CENTER 0-VENT PIPE --EXTERIOR LOCATION I_ ABGGE6s e5 (20)PROPOSED PV MODULES `' _ __ _ ARCA RCSCT.VCD f uR P L. ' "•"-IST FLOOR LOCATION Q a 9 iew Note BASEMENT LOCATION LL Town building examiner has received the enclosed document for minimum acceptable -GARAGE LOCATIONI �,.�•' �:� plan submittal requirements of the town as specified in the building and/or Residential Code of the State of New York. This review does not guarantee compliance with that -- code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal and signature has been PROPOSED PV SYSTEM interpreted as an attestation that,to the best of the licensee's belief and information Module Type/Qt 28 SN20-72MBE-390V :he work in this document is: YP Y� ( ) Accurate, • Conforms with governing codes applicable at the time of submission Module Dimension: 78.03"x 39.45"x 1.57" w Conforms with reasonable standards of practice and with view to the Module Weight/PSF: 49.38 lbs/2.3 PSF 1e- VENTILATION safeguarding of life,health,property and public welfare is the responsibility of the - - licensee. - -18•-VENTILATION ' Micro Inverter: (28)Enphase IQ8PLUS-72-2-US B•.YENTA ATION -10'-VENTILATION Structural Statement System DC Rating: 10.92 kW r - a:= • The existing structure is adequate to support the new loads imposed by the Estimated AC Production: 12,293 kWh/yr (B)PROPOSED PV MODULEStl, ; o photovoltaic module system including uplift and shear. The existing rafter sizes -i and dimensions conform to RC-NYS 2020 table R802.4.1(2)-Rafter Spans. Production Source: Aurora ' PV Notes 1. This PV system has been designed to meet all current and applicable fire prevention setback pathways per 2020 NYS Residential Code. Proper ground clearance,roof accessoints,access pathways and ventilation systems shall be provided where necessary. An in depth description of each applicable code AREA RESERVED FOR AHJ: reference and exception for any codes is depicted on the PV-1 plate of this drawing package. !�I I� 2. Roof shall have no more than a single layer of roof covering in addition to the ll 1 9n77 solar equipmentDD . 3. Installation of solar equipment shall be flush-mounted,parallel to and no more than 6-inches above the surface of the roof. BUILDING DEPS 4. Weight of the installed system shall not exceed more than 5-psf TOWN DI SODEPTIaD 5. Any plumbing vents are not to be cut or covered for solar equipment installation. Any relocation or modification of the vent requires a plumbing permit and FULL HOUSE ROOF PLAN inspection. SCALE:N.T.S. This PV system has been designed to meet the minimum design standard for building and other structures of the ASCE 7-16 and the 2020 New York State Residential Code. PV1 =0 COVER PAGE JOB# 22332 ,J REVISION # N/A SIJI®IAMON �` C,7-i�, R G Y REVISED BY N/A RIDGE � � 29'-5" / • N� V3 • • . ® . • • • • . • . .• 9j� 02.B'11 Q • CIRCUIT 1 4$' � '� • �o • / N% • 19-4" @) s S NATION V�77 ENERGYy • PHOTOVOLTAIC MODULE SUNation solar Systems t rki;L j ® ® • (TYP) 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750-9454 CIRCUIT 2 N S IALLE 4355 NSTALLER NUMBER JOB NUMBER 3'— GUTTER ROOF AREA 22332 29'-5" ROOF 1 30'-5" RIDGE RIDGE CAPPING (TYP.) LOO N _ N ■ o � U Z O X O QQC O 0 ,N N N ❑ ¢Us O oC o Z �� m 13'-10" V W .n-1.e Uj • O 0 T • • (n07 m m • • O O � rd* ` CIRCUIT 3 GUTTER ROOF 2 16,-10y2„ Attachment Spacing: Portrait Attachment Spacing: Landscape Roof.# Roof Description Modules Azimuth Tilt Pitch Interior Edge Corner Interior Edge Corner 1 Southwest Roof 20 2240 180 4.8/12 48" 32" 16" 64" 64" 48" 3/16"= V-0" 2 Southwest Roof 8 2240 180 4.8/12 48" 32" 16" 64" 64" 48" Alml PARTIAL ROOF PLAN SOLAR ENERGY SYSTEMS ' (NY) R324.6 Roof access and pathways. Roof access, pathways and setback requirements shall be provided in accordance with Sections u R324.61 through R324.6.2.1. Access and minimum spacing shall be ❑ s � required to provide emergency access to the roof,to provide pathways (EXT) to specific areas of the roof, provide for smoke ventilation opportunity areas and to provide emergency egress from the roof. I Exceptions: (EXT) -- "y X298 � 1. Detached, nonhabitable structures, including but not limited to detached garages, .parking shade structures, carports, solar trellises and similar structures, shall not be required to provide roof access. 2. Roof access, pathways and setbacks need to be provided where the building official has determined that rooftop operations will not be employed. 3. These requirements shall not apply to roofs with slopes of two SUNAaTION units vertical in 12 units horizontal(17-percent slope)or lessf ENERGY [NY] R324.6.1 Pathways. Not fewer than two pathways, on separate SUNation Solar Systems roof planes from lowest roof edge to ridge and not less than 36 inches 171 Remington Blvd. (914 mm)wide,shall be provided on all buildings. Not fewer than one Ronkonkoma,New York 11779 } (631)-750-9454 pathway shall be provided on the street or driveway side of the roof. a For each roof plane with a photovoltaic array, a pathway not less than w FT ROOF ACCESS 4355 36 inches (914 mm)wide shall be provided from the lowest roof edge >_ sue as- NYSERDA ¢ (e) INSTALLER to the ridge on thee same roof plane as the photovoltaic array, on an - o =_ - NUMBER adjacent roof plane, or straddling the same and adjacent roof planes. o ensPSS Pathways shall be over areas capable of supporting fire fighters S JOB NUMBER accessing the roof. Pathways shall be located in areas with minimal w 22332 obstructions such as vent pipes, conduit, or mechanical equipment. ~ W Pathways on opposing roof slopes shall not be located along the same 0 18"-VENTILATION plane as the truss, rafter, or other such framing system that supports Z 18"-VENTILATION the pathway. w - Exception: U) o 1. Access pathways shall not be required on roof slopes containing LL photovoltaic modules, panels, or an array where the opposing F— ACCESS (20)PROPOSED PV MODULES LO N or adjacent roof slope is an access roof. o �` o cc Z Access Roof-A roof surface that: LL z o m CD c n 1. Can be accessed from the ground by the fire service. 2p 2. Is capable of providing fire service access to the ridge or peak p (6 LD m of an opposing or adjacent roof surface that contains L- E m m photovoltaic modules,panels,or an array. Y vi 3. Is relatively free of vents,skylights,conduits, mechanical LU a equipment and other such obstructions. in ca m 4. Does not contain photovoltaic modules, panels or an array,or is a single ridge roof where the maximum edge to edge width of ACCEss ov o the photovoltaic panel system does not exceed 33 percent of ROOF n the ridge length. -18"-VENTILATION [NY] R324.6.2 - Setback at ridge. Photovoltaic arrays shall not be 18"-VENTILATION located less than 18 inches(457 mm)from a horizontal ridge. 18"-VENTILATION 18"-VENTILATION [NY] R324.6.2.2 - Emergency escape and rescue opening. Panels and modules installed on dwellings shall not be placed on the portion of the roof that is below and emergency escape and rescue opening. (8)PROPOSED PV MODULES 0. A pathway not less than 36 inches(914 mm)wide shall be provided to the emergency escape and rescue opening. 3/32"= 1'-0" A1 =4 ROOF ACCESS PLAN Typical Attachment Methodja �� �. ®� RIDGE SNAP'N'RACK UL 02.981 O � PHOTOVOLTAIC 191-411 L-FOOT AND RAIL AS ` MODULE m 3/4"MODULE SPACING BETWEEN ROWS AND (2)S.S.304 5.OMM X 60MM COLUMNS(TYP.) WOOD SCREW FASTENER. I /,d SUVA ION ENERGY RT-MINI ROOF ATTACHMENT SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (631)-750-9454 RAFTER (1)LSHINGL ASPHALT o NYSERDA 4355 211 X 10" 24" O.C. SHINGLE(TYP.) NUMBER INSTALLER JOB NUMBER PLYWOOD DECKING 22332 (TYP.) SOFFIT WOOD FRAMING EXTERIOR (TYP-) WALL ATTACHMENT TYPE APPLIED TO-ROOF-TYP- 171-011LO —I ROOF SECTION (TYP.) - M N SCALE: N.T.S. T N Z U z O C } SOLAR MODULE FRAME NOTE:3/4"SPACING .� •� O BETWEEN MODULE ROWS T Roof# Rafter Size/Spacing Max Span Material Layers Sheathing M- i ".0 AND COLUMNS. O C aS co 1 2"x 10"/2411 O.C. 171.011 Composite Shingles 1 Plywood 66 HEIGHT ADJUSTABLE LL E L-FOOT(TYP.) Z = J m 2 2"x 10"/24" O.C. 141-911 Composite Shingles 1 Plywood END LAMP H � Cn TE SNAP'WRACK L (� m 6.0" ULTRA RAIL CO (TYP.) 07 ♦ ♦ 0 HEIGHT OFF OF 0- ROOFSURFACE0 Q RT MINI 2 (TYP.) Typical Module PEST WRAP CUT AWAYFOR Side Profile CLARITY CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) WIND DESIGN SUBJECT TO DAMAGE . ICE BARRIER SEISMIC DESIGN WINTER DESIGN UNDERLAYMENT FLOOD HAZARD AIR FREEZING INDEX MEAN ANNUAL GROUND SNOW SPEED(MPH.) TOPOGRAPHIC SPECIAL WIND ZONE WIND BORNE DEBRIS CATEGORY WEATHERING FROST LINE DEPTH TERMITE TEMPERATURE REQUIRED TEMPERATURE - LOAD EFFECTS ZONE 20 PSF 140 B NO 2 B SEVERE T4' MODERATE TO 15 DEG N/A SEE PLANS 599 51 S I HEAVY EXAMINER STRUCTURE • � , ►fir � 0) ` 029 11 O� Enphase A/C Branch Circuit(typ.) 120/240v UTILITY SERVICE N Enphase Microinverter(typ.) - r COMBINEZ'*" ENERGYSUNAi®� Module J-Box(typ.) � � PANEL � CONNECTION _ M '� ����GY SU71 Re Solar Systems I/ \I 171 Remington Blvd. Ronkonkoma,New York 11779 (631)-750=9454 PV Module(typ.) NYSERINSTALLER 4355 EGC Attached To Rail(typ.) 200A NUMBER MAIN =E GATEWAY �5 JOB NUMBER (No bads,monitoring only) 2P15A 22332 _ Esv�ca.way CONDUIT AND CONDUCTOR SCHEDULE 2P20A 60A ENPHASE BRANCH CIRCUIT#1 Circuit#1 MAIN TAG CONDUCTOR CONDUIT RUN ENPHASE BRANCH CIRCUIT#2 C2P10A TYPE GAUGE QUANTITY TYPE SIZE LENGTH ENPHASE BRANCH CIRCUIT#3 21`20A 2P60A 2P20A 1 Enphase Q-Cable 12 6 N/A N/A 15' EGC Circuit#3 IQ Combiner Sense MONITOR 2 Type NM 10 6 N/A N/A 30' LG G (No loada,mnnodngo* C' . MAIN 3 HWN-2 10 6 PVC SCH.80 1.25" 15' 1 2 3 ENPHASE A/C SERVICE Lo IQ COMBINER DISCONNECT PANEL N GC 8 1 PVC SCH.80 1.25" 15' ROOF ATTIC EXTERIOR T N SERVICE RATED T O 4 HWN-2 6 3 PVC SCH.80 1.25" 10' 4 ENCLOSURE 6 GC 8 1 PVC SCH.80 1.25" 10' MIN.22k AIC z 0 Z O 5 HWN-2 3 3 PVC SCH.80 1.25" 10' — LD O 6 GC 6 1 N/A N/A 10' BUILDING 4 GROUNDING Q ELECTRODE U. E N Z Cz J m Circuit# PV Module Qty. Micro-Inverter Qty. Maximum AC Operating Current _�e uj 1 SN20-72MBE-390V 12 Enphase IQ8PLUS-72-2-US 12 14.52 A N m0 ' m � En hase IQ8PLUS-72-2-US 2 SN20-72MBE-390V 8 P 8 9.68 A p � Enphase IQ8PLUS-72-2-US CL cz 3 � SN20-72MBE-390V 8 P 8 9.68 A o 0• t` Maximum AC Operating Current(Total) 33.88 A Elml , ONE-LINE DIAGRAM LABEL LOCATION: LABEL LOCATION: � � 1 �� I WARNING: • • • ° CONDUITS:1 AT EVERY SEPARATION BY ENCLOSURES/WALLS/PARTITIONS/ Service Disconnect MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SE ICE CEILINGS/FLOORS OR MORE THAN 10'. DISCONNECT IF APPLICABLE. • • ofI i NEC 2017 690.31(G)(3) NEC 2017 705.10 ti Sec • • Disconnect Q� • LABEL LOCATIONp{ MAXIMUM AC•' SOURCE CIRCUITS: 1 AT EACH AC DISCONNECT,COMPLETE VOLTAGE AND Located • loll • OPERATING CURRENT VALUES ON DISCONNECT LABEL. NEC 2017 690.54/NEC 2017 690.13(B) '— NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO ° THE BUILDING MAIN SERVICE DISCONNECT. This building is equipped with an. WARN ANG I Interconnected'Electric Power SUN�°T�I®N Production Source j �t�1RGY of ELECTRIC SHOCK HAZARD j f DO NOT TOUCH TERMINALS REMOVE NOT SUNation Solar Systems Source Type: 171 Remington Blvd.Ronkonkoma,New York 11779 i S"olar Photovoltaic i � (631)-750-9454 TERMINALS ON BOTH THE LINE AND - • Disconnect is Located: Interior. LOAD SIDES MAY BE ENERGIZED Located Service Panel Basement_ Garage:_ Exterior._ j NYSERDA 4355 IN THE OPEN POSITION in Main Front_ Rear._ LH Side:_ • • • ° INSTALLER PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE - RH Side:_ Other Location: i NUMBER WHENEVERTHEYARE EXPOED TO SUNLIGHT ■ .WITH ° , SUN'ation Solar Systems I JOB NUMBER 631-750-8454 www.sunation.com � SHUTDOWN 22332 SOLAR SYSTEM EQUIPPED ; LABEL LOCATION: - ---- WITH RAPID SHUTDOWN_ 1 AT PRIMARY DISCONNECTING MEANS FOR THE PV ARRAY ON EXTERIOR WALL TURN RAPID SHUTDOWN SWITCH TO THE NEC 2017 690 'OFPPOSITIONTO 'wvuas SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LID O) N r N - r O � N O Z C) z O n N 0 m O c Z = J Ib W M U Cf) H fn N :3 >+ • IYl � m C Cr 'S as E2= 1 PV LABELS r• Y qac c Mx ,r . 3 ju IVA zw ` �,a at"'k��Cyr ?��.x �, ? ,. - �. ��.> f, ! 'tom, / f'• !�j` r .,V�' 47�k• �, Yom"r' .. y��`. ., S f 4 �C 'ly.=_.iJ� •rr. _ �:a+r t lRt `, f .f� a'�' , a•,••. T '• . - . �'�F' .��`'• Y� ,•�"'•�._'_" ` .'F �-`+ �'S�s � ^, ak` �v��"'�h r�F +. Ste. - .:.... w..,,,el r. ��' "�, ''!,......+r; •ai'�ila.�?.i�. �v�".9V- '�hr. ,. � .. �� ai'�",�a v"`. e"�'S_ �,�` � _ ' f: �. r`�_'!a' "�.. • 'per^...- $�+�.,. ,,�•,+� w `Tr ..:f ;: �" a,.:'. P t�,.+la1YP yir.�YF: .i�: � {��y�'i. _' ''�� _ .� F I�, �/FIY 'w y•- J ! •\\\1. C• f�1! , • 17 '7✓ � �� � � 'i•j�4[�I® 5.�;i. { � .��' �,'`""�Yw{j:_.2ne�/f�! :rq '''' � � � :� � i� �_ �`.: tge • toy '-a r , r, i..—��-"S7�T'j }t,. .t'� ¢L •�•Y �1 w J • �` j 1 ' I ! � �'' � F+. _ i .,fir r _s•;7'a' n,S:. 1 :/} 1 :N,^�G• n �a ° �.: t �J Graham Associates 256 Orinoco Drive, Suite A Brightwaters,NY 11718 Building Consultants & Expeditors (631)665-9619 July 6, 2022 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Birenbaum Residence 740 Poquatuck Lane Orient, NY 10.92 KW Rooftop Solar Photovoltaic Systems To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE?-10 If you have any further questions, do not hesitate to call. � - A 7� :�. X17 K Dunn, RA -...........x. ... .:::. ^�.� w. .,.....,......u.vt,................ ........ ...... a ... � .,. ... ..\.....v....x::.>. ...�cw:..Cv., k ,.,,Z., >... n:. ...>....,.. ._..qu£. ..............f. ..\....b\.\\\,`VH.., .... ... \4 :� ��.,>.:.:-:. ............... .._.:,.,c ...... n.... ... ...:,_. ,ro .ay.._........\..�t�A >i �....,.......:kx\ ..t�"'.::. .. ,��:i:. .\�t:.i.... ,..._.... :, Ott.. .. :. , ... .. ... .:..,.. ....... ........ r:,.,<.::.:� x ,.. ... :.` ....E ...... �, .% \, .... . .. ...... ..d, .. .__ ,.. ........ ... .\_ a ...,vv ........ #`< .... b.-.>.,. .. ._...a.Af,.. „ ;b;?;_',x ``r•ri.;::..v.3; :�� xro�' >t :. .u< , ,<., ....t ...': ...., �iq�.Y ., .,,•.... :o:- � .3 wweh': t � �P ........ ar � ?,,. , �`��.3 L' t� 5 `.� �:�:;��.� .� i§.B� F '{F3 ,....\.. __, £,,i ���xtnn sp A, :t.\. "t�N'£ :•�:�t , .......... ... ,...`R♦.z :�.� ..........:....:.. .\._,..,1,.,..�1Y\, ..v::.::.:-..:�...::;;,b`�;,.';,:i:`.�'�i :�``�.`:.,:�i::.c„.. ::.:50;: � �::v:S%:S:f',:.�! A „£. ...� .b...,..,na .. ♦x.,.,.. ..,,. .{. .a.. ..............E ....,..\ .� S..fE:.: _�.' `.`x'�"^ aS:Y::;• to ( •.. ..,_,,..,....a..: ::;T,��` 4-62 ....CGCG .'� • t....... .. ,�n'i?b .:.... .......... ^� X.,.:"o.,,,: r .. .. .. .... ..............n..w a. A„ .,. .> .. .... .. ...., r .. ....,..,..... .... :. x. .. .A]?max.. ,f.';4`.";.` nb .i g , {t f< 4....;.. Fi , FEATURES Enhanced External Load/Impact F # -' Snow Load: 00 Pa Wind Load:2,,44 00 Pa u® z 4 ' Fire Safety Spread of Flame Class-_„ A Burning Brad Class C F PID Resistance Enhanced Potential Induced Degradation Resistance Higher power output ®3� 0—+5Wp Higher than rated power , I®��nl�l III VIII Excellent performance under I® : ''.... low light conditions '= Cloudy days,mornings and evening . Various Options Available Black or Silver Frame Or ) WARRANTY CERTIFICATIONS 12-years Product Warranty IEC 61215,617301 UL 61730 25-years Linear Performance Warranty ISO 9001 :Quality Management System ISO 14001 :Environmental Management System 5-Ener s Linear Performance Warranty OHSAS 18001 :Occupational Health&Safety System 95j -------------------------------- ---- ------------ ---{ v �a7Q ................. ....],.„---mcg-- ----- \��}�{,X�..'x{�/ GO� w . .a ❑ CE 5r us N 75 o s so a :o xs :Industry . ....:.......... .ro :.....,....-,'.,v"'C' etm'«.,:..,.,......y...:m:...<y„riw.�,wvv.r».w....'rc..,,w w,...".............K.;..,tm, `",i.1"'.:�” w....,..'...�.",. •�xvV,im �n.:K'.v. Ia.#L.`:k,f...,.....:b, ......... . .. ............: ........ ...,........,., ....u .... (: .4:°�;'.:'.'.l.,�:A.v;:,.:..:........ .ir�£b;:i:<aY: r� <.v' .:.. �.]`c q't'r:`:'�:`.ro• "...v ...,,..v>.s.:a .:.....:__ .., \...,;.,.. ,....c �. .......... ...:x.........,.,. ....,..,40,..:��::'3. t .:%.�i:'i..:ix;:i::;F":i .,. .. . ... .r.>,,.,,. w. y t,n.;.�yl,(. •s..o.. . 33s, : ei'`xi�-o. t .:i::f'f ac at oxcs; ..i a`•i':,'yF'..c,,.:, :.s ,c, "'�,. x?{>t° ;r>;�#�1rr: ,t}3 E t .,.�I.$�i'<:iiii��i.I„L;,�as4.t.,...�t�...:.;�.:���rc;;,il,:?i~`''- ,s�.r (( .•.:�"'€?fit4 .-cY •..,..:.�;:..,..>.:...<: m.': ..:.,:�»S;.i.�. .ala., a-;,�::;';,':t.:: P:::::.... .. :6',;t �:,r\-X. a..... ,v. ..: .,. ., •' .r�i ,'�f,:.:n':.,.:.�,;tb.,3:;:,;>.....r .':C:'. t �3(`.'£'?.'�.`a:f:...::.......:.. :.... <Y x . ......;... .... ....:�#...:€x xx.p5 >.. :::.:-r:?::.:�:..�:,''a,..,3x.: ;3...�,._Y.x, a.�'.., a #.n�.r<.:7•,5�'8�-t�z ajj'T�; ]a;'�,:;°: ....T..... ..5... ........ ._...., ._............... .. ..... .... ........ .:.�r:..; .....,...(.. _,.,.,.a i „! iii ^. A .t ..:,...., . �:. .\a F ., n...,. pp ( € ., _. ................ .... :.xr�.s. ..,. .:.Y ..,,,:,...n .�., .. � ._��c..i�_]�x»:,«Y:•"t��. ,o`$x.] r:'zzi:3' ""3f3x' �` ..,« �....... �:,. . � o, _... .. ,>. �, ro .............. ; —. ,.b�. b.5 _.3_s�ss_i>.e:.,w,.i#t'C°::�:? ,.4 �.d�..•: r� i'�., , t E,.....__>._:m.». .. .. .x... . ..,..x< ...... .. .................._..tiro �, .:.. _.t. . ....:..,,,=F..\.. >�; .. ......,,....... ... .....,...,.,........._,,. ;r .;,t. - ._..... `ea`s'y . ;�<.£_�. r ,:...._:_,.. ,..:,.a.....;x t�;, ..`s......,.. k .....��,.,, _.........:.....�,v ._,�,. .:akEr.• ` a<s"i-s%i5":� A..... ... .. ...�\...:t. •<,..:... �... ._ ,. .., :., .::._Z:�::a•........:.....' ;,..�:�::�;` :v�YA`.1.,.....:"fit:.' .,..� ..aE:.. c:;.g rr. , s V N20-72 AE/ /MCE 7,000v S-Energy 385W•39DW•395W Monocrystalline PV Module t ELECTRICAL CHARACTERISTICS STC(Drm!aDDs2MAh ts! SN10-72MAE/MBE/MCE-385V SN10-721VIAE/MBE/MCE-390V SN1042MAE/M8E/MCE-39SV ... ".... ......-_.-.... .. ...."......................._.... ....,...._",..._._-__. ,,......"........:._...-........ .,.._"............................. ..._. . Rated Power(Pmax)Power 385W 390W 395W Voltage at Pmax(Vmp) 40.2V 40AV 40.6V Current at Pmax(Imp) 9.58A 9.66A 9.74A Warranted Minimum Pmax 385W 39OW 395W Short-Circuit Current(Isc) 10.09A 10.18A 10.27A Open-Circuit Voltage(Voc) 48.7V 48.9V 49.1 V Module Efficiency* 19.39% 19.64% 19.89% Operating Module Temperature -40°C to+85°C Maximum System Voltage 1,000V Fuse Rating 20A Maximum Reverse Current 27A Power Tolerance 0-+5W MECHANICAL CHARACTERISTICS �unctlon box 10x10(0.39x0 39: — — Solar Cells Monocrystalline Cells 15B.75xl58.75mm Oroiacga t a:s 4 pcce I NumberofCells 72 Cells(6xl2 Matrix) 109(0.554,35)' i Dimensions r 1,982 x 1,002 x 40mm tAcunl!rg sat 8 place ! Front Load 5,400Pa j Rear Load 2,400Pa I Weight 22.4kg (i j Front Glass ( 3.2mm High-Transmittance Low Iron Tempered Glass �6(0.24. `41 i ! £ I .. .... . ......_.. . ._ OrrA;nd hales i Frame Anodized Aluminum Frame(Silver/Black) IT ............. .............. . .. .............. -..... -- ' J-Box IP68 with 3 bypass diodes Output Cables PV Wire PVI-F,12AWG 4mm2),Cable Length:9DOmm Connectors. MC4 Compatible TEMPERATURE CHARACTERISTICS 952(37.48) 1 P ! Temperature coefficient of Isc 0.05%/DC ;.._..................................................._..........._..................................... . 100209.441 Temperature coefficient of Voc -0.29%/°C .. .. ... ... .. .._ ._ r.Ary lace! Temperature coefficient of power -0.39%/°C NOCT(Tair 2o'C;Irradiance 80oW1m2;Wind lmis) 45±2 DC - .,.w.,....,....,.,,....�,.,,, 11—,PPd'N iSY N0 1D WtAf0E0v1.M' I PACKING CONFIGURATION Container 20' 40' a ° C.Pmpp•3 Modules Per Pallet 27pcs 27pcs 44 Pallets Per Container lopallets 22pallets %'• _--`"" 66 f`.. --- .. 'I, D 10 30 A b 50 ° 10 20 30 t0 Modules Per Container 270pcs 594pcs wn�N vD4.9DN ........................................................................................................................... ..................................................... Pmax measurement tolerance:±3% Installation instruction supplied with the module must be S-Energy uses triple A class simulator. duly followed.Forfurther information which is not REMARKS Specification subject to change without prier notice- NOTES mentioned on installation guides or directions,please S-Energy reserves the rights offinal interpretation contact to ourtechnical service department. E-mail:inquiry(Os-energy.com TMr c „ _.. t ' ENPHASE. m IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling ;�- -- Enphase High productivity and reliability { Produce power even when the 1year limited grid is down warranty • More than one million cumulative Part of the Enphase Energy System,IQB Series I08 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules smr CERTIFIED Microgrid-forming Complies with the latest advanced grid support Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements IQBSP-DS-0002-01-EN-US-2021-10-19 IQ8 and IQ8+ Microinverters IINPUT DATA(DCI IQ8-60-2-US ,:. Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module Iso] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA(ACI 108-60-2-US 1.. Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit' 16 I 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 lbs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor ' CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 69012 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 S- ERIES FLASHE ® FOOT - 7 SnapNrack Reside.nti-al�'PIV-.M.ounti�ng--SysteM's The SnapNrack line of solar mounting .`''�•�-',..:N,,,'. •-'-s� . ".-�t:.-.'mss-`-: �.� yr systems is designed to reduce total n4-5 =-� �+ � w= a `= x G�Ri3�� .�-Yi5'�i'� :ate-is'� '�• =r�r>�:_��.. �: installation costs. The system features =� ;�� ���� �� � =��:�� "�` �:-�-�*=4=�=-• technical innovations proven on more ��= -� --1• �� than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified sr - AIML SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over t.• s ��[� ,',. the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles.The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1"slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact SnapNrack­ Patent Pending FV MV ou htnng syzftmo i Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1°spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions �SNAPNRACK CHANNEL NUr 1 N -SNAPNRACK 92 DEGREE L-FOOT,CLEAR I 1 -511618 FLANGE NUT' �5JIG18 X LIN BOLTWITH / SPLIT l)IX WASHER -SNAPNPACK COMPOSMON FLASHING 'f 4 O 3.43 \\-SNAPNRACK L-FOOT BASE .B8 SnapNrack Flashed Foot Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship Snap'�",\,,� rack- F�Y r'�y J'jI�)1.�71�115�9nz S S51n (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2013 by SnapNrack PV Mounting System.All rights reserved. SERIES ROOF SnapNrack Solar Mounting Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar installations. Pitcher! Roof Arrays SimplifiedJf _ r fix:�y�rf,••�;;� ��:';�_ y-.` The SnapNrack Series 100 UL Roof Mount System _ '..;�.,•,;>: ="" 4% `:f> is an efficient, visually appealing, photovoltaic (PV) ��� � --�-�i���=:=�-��,��;�._-��;�=�•=���w'H�,=fi�.'91 module installation system. Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select j an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) Identify Site Conditions (Array Tilt. Building Listing ensures that SnapNrack partners can provide Height, Roof Type,Wind and Snow Loads) the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. 1 • All bonding hardware is fully integrated into the { components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules �` LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel, SnapNrack Bonding SnapNrack Standard Rail Split-Lock Washer Bolt with Split Splice Insert Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding V Bonding SnapNrack Stainless Adjustable End Bonding Channel Nut Clamp Bottom �Channel Nut Stainless Hardware with Bolt with Split-Lack Washers Split Lock SnapNrack Bonding Washer Adjustable End Clamp SnapNrack Bonding SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG CopperWire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF F IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding i Standoff Clamp Assembly SnapNrack Serrated Stainless*92 SnapNrack SnapNrack Bonding Rubber Steel Flange NutBonding Channel Nut Channel kF ainless Rain Collar Serrated StainlessNut �, a Standoff nge Nut Steel Flange BoltSnapNrack Stainless SnapNrack Degree Flange Mill Finish L Foot Bolt SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) o SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Metal SnapNrack Bonding SnapNrack Bonding Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack Series 100 UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum •Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) S nc�pfN' f1rack- SoBar Mounting Solutions (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. ©2015 by SnapNrack PV Mounting System.All rights reserved. `��I�►"' - ®-UTILfiY METER .. .. . PLA _ SERVICE DISCONNECT � ® 1 M _ P- R OPOS-E D RE S I. DiN T 1 A L . PV1-0 O R S ©-SUPPLY SIDE CONNECTION ( AL ROO Q-AUTOMATIC TRANSFER SW RCHAi-1 AR - A: DD -: -0N:. --P 'V SYSTEM . Al-2 ACHMENT PACING PLAN S-GASMEfER" ROOF SS PLAN ®-,MAINSERV16EPANEL .. (EXT) - (/. - 435 -Su0 PANEL 5 / 1 RUCTUREnti •' SUNATION SOLAR SYSTEMS NYSERDA ®-WIRELESS ROUTER .. . 171 REMINGTON BOULEVARD INSTALLER 1 ONE-LINE RONKONKOMA,NEW-YORK 11779 NUMBER ®-INVERTER ,. P EL'S V !]-ENPHASE IG COMBINER Birenbaum Residence - .. .. -' l w� os ®-PANEL 740 Poquatuck Lane; Orient,.NY'11957: ���®�1!• Q-ELECTRIC VEHICLE CHARGER "C• -ENPHASE ENVOY w ii 0 L -SENSE CONSUMPTION MONITOR �(,ISTEIQ wn By:J De aRocca 5/17/2024 .. ®-AC DISCONNECT .. W ! CN/� �� .Q-TESLAGATEWAY Ix ATS n .. .. - .. . ®-TESLA POWERWALL (D O ACCDEss .. _ .. - . Si10(B U MSP SS ... �-ENPHASE 10 SYSTEM CONTROLLER .. .. Q-ENPHASE 10 LOAD CONTROLLER A - (17)PflOPOSED PV MODULES v EN PHASE IO ID BATTERY •. AVA �• fO 7 2 iB` ®"ENPHASE 103 BATTERY .. 18'•-VENTILATION VENTILATION •. .. .. - .. . • . - - 8 rz -GENERATION PANEL -. 0 ... .. ®-BACKED UP LOADS CENTER 4�, W Y OR -' .. .: ©-VENT PIPE .. .. .. .. .. G PV MODULES - - -.OOF (20)EXISTW -EXTERIOR LOCATION .. - - .. ACCEEssI 1 ST FLOOR LOCATION - .. : ' Build ng Review Note BASEMENT LOCATION, : .. Town building examiner has received the enclosed document for minimum acceptable ' a` GARAGE LOCATION - .: ... . plan submittal requirements of the town as specified in the building and/or Residential . - Code of the State of New York. This review does not guarantee compliance with that code. that responsibility is guaranteed under the seal and signature of the New York State licensed design professional of record. That seal and signature has been .:PROPOSED PV SYSTEM interpreted es licensee's _ information in ed as an attestation that;to the best of the li belief and the.work Module Type/Qty: (17)SL65-54BHJ-400V ACCESS Accurate dooument.is:. AooF e• Conforms with governing codes applicable at the.time of submission Module Dimension: 67:8"x 44.85":x 1:18" i. Conforms with reasonable standards of practice and with view to the ACCESS ACCESS safeguarding of life,health,property and public welfare is the responsibility of the Module.Weight/PSF:. 47.18 Ibs/ ' 2.2342321 0 1 1 0397 PSFVENTILATION.. .". .•. VENTILATION .. l(Cen See • Micro Inverter: (17)Enphase IQ8PLUS-72-2-US VENTILATION .. - ... .•. -10"-VENTILATION -:•. :. Structural Statement - -. -- System DC Rating: 6.8 kW - =. System AC Rating: :4.9368 kW/AC D s -and s co C-NY table 02 4 O aft Spans. eexismgsrucue(sa adequate photovoltaic module system including uplift and shear. The existing rafter size Aurora Estimated AC Production: 5,934 kWh/yr (B)EwsnNGpvMoouLEs a dimension conform to R S 2020 a R8 1 1 -Rafter.S a '. PV Notes .' 1. This.PV system has been designed to meet all current and applicable.fire. EXISTING.PV SYSTEM: prevention setback pathways per 2020 NYS residential code. Proper ground clearance,roof access points,access pathways.and ventilation systems shall be Module Type/'Qty: 28)SN20-72MBE-390V provided where necessary. An in depth description of each applicable code AREA ! nce and Module Dimension: 78:03"x 39.45"x 1:57" # drawing packageCep r e - o 2 exception o any codes-is depicted on*the P pla e f this MCA Fi�S���S��'"�R AH.... . . . Roof shall have no ore t of roof co addition Module Weight/PSF: :49.38 Ibs/23 PSF solar equipment. : m ! 3 _ -m rall d no more 44 than a single layer covering in a • 1 ' i Installation of solar equipment shall be,flush ounted,parallel.to an Micro Inverter: (28)Enphase IQ8PLUS-72-2-US. i " " than 6-inches above the surface of the roof. System DC Rating: 10.92 kW f. 5. Any plumbing ht Pe(vents are not o be Gstem lut or covered for solar d more thana usment installation. " �• Any relocation or modification of the vent requires a plumbing permit and . System AC Rating: :8.1312 kW/AC ( :" inspection. Installed by: SUNatiori Solar Systems LL SOCALE:N.T.S.O PLAN This PV system has been designed to meet the minimum design standard for building " FU N ! and other structures of the ASCE 7-10 and the 2020 New York State Residential Code. - .. f COVERPAGE _ Pvri -MO .: am[ �A JOB# :- 029.26­ .: REVISION #. N/A b. SUNATION ENERGY REVISED BY.:: :N/A GIS IGHi 29.6. .. .- - 09 YO V, • • ROOF 1 IAL xC; ❑ ¢� • '.: PROPOSED CIRCUIT 4 SUNATION • %• ENERGY SUNation Solar Systems 171 Remington Blvd. Ronkonkoma,New York 1177 9. ' `.` (631)750-9454 EXTEND CIRCUIT 2 RIDGE NYSERDA INSTALLER A V; - NUMBER 4355 : • JOB.NUMBER a 47 r: . 02926 ... ... .. EXISTING CIRCUIT 1 - � • EXISTING CIRCUIT 2 LO EXISTING PHOTOVOLTAIC � :. :.. :.. :. N M ) .. .. - .. .. T O ... GUTTER .. a � � CDO r, RIDGE RIDGE CAPPING � ai' � .. .. .. (TYP.): LL E .� .. ro .. .. .. .. .. .. - .. ... N .. .. .. ... .: """ .' .. m � t W Cl) q . � RCUIT 3 r. I � ` • U N� : GUTTER .. .' .. .. .. .. .. .. .. .. ... 16 .. .. .. ROOF AREA 1/8" ='1'-0".. At tachment Spacing: Portrait Attachment Spacing: Landscape Roof#' Roof Descri tion Modules_p Azimuth Tilt Pitch Interior Edge Corner.: Interior Edge Corner At lv . 1 Northeast Roof, 17 430 190 5.1/12 48" 32" 1611 6411 64" 48" PARTIAL:ROOF PLAN . ..ftft—! tGLAR ENERGY SYSTEMS (NY) R324.6-Roof access and pathways. Roof access, pathways and �G'STF� setback requirements shall be provided in accordance with'Sections R324.61 through R324..6.2.1. Access and minimum spacing shall be � M► ' H required to provide emergency access to the roof,to provide pathways �a. IFto.specific areas of the roof, provide for Smoke ventilation opportunity areas and.to:provide emergency egress from the roof.' Exceptions: :. (Exr) " � 1: Detached, nonhabitable structures, including but not limited to �j detached garages, parking: shade structures, carports, solar Y _ trellises and similar structures, shall not be required to provide. roof'access.: 2. Roof access, pathways and setbacks need to be provided where'the building official has determined that rooftop operations will not be employed. 3. These requirements shall not'apply to roofs with slopes of two units vertical in 12 units Horizontal(1.7-percent slope)or less . ' w. ENERGY > [NY] R324.6.1 Pathways. Not fewer:than two pathways, on separate ¢ on Solar stem ❑ S 171 tRem ngton Blvd.s roof planes-from lowest roof edge to ridge and not less than 36 inches. . p Ronkbhkoma,New York 11779,. (914 mini)wide,shall be provided on all buildings. Not fewer than one O (631)-7.50-9454 pathway shall be provided on the street or driveway side of the roof. W UJ. ..ATS .. For each roof:plane with a'photovoltaic array, a pathway not less than NYSERoa 36 inches(914 mm)wide shall be provided from the lowest roof edge sus (B a A ccEss INSTALLERr.D 4355. to the ridge on thee.same roof plane as the:photovoltaic:array, on an: z == ss 36 NUMBER - .. — MSP - adjacent roof plane, or straddling the same and adjacent roof planes. a C Pathways shall be over areas capable. of supporting fire fighters ` P JOB.NUMBER accessing the roof. Pathways shall be located in areas with minimal " (17)PROPOSED v MODU LES ES obstructions"such as vent pipes, conduit, or mechanical equipment. 0 - 02926 Pathways.on opposing roof slopes shall not be located along the same x is"=VENTILATION.LL plane as the truss;rafter, or other such framing system that supports o 18".VENTILATION the pathway. a z i >.' l Exception:: LL .r 1. Access pathways shall not be required on roof slopes containing -. - RODF t ISTING PV MODULES photovoltaic modules, panels, or an array where the opposing AdCEss .. .. > - - or adjacent roof-slope is an access roof. 36'` Z N (20)EX MOD .: .. .. Access Roo -A roof surface.that: : : 0 c f 1: Can be accessed from the ground by the fire service.- O_ 'o 2. Is capable of.providing fire service access to the ridge or peak LIL - E ' of an opposing or adjacent roof surface that contains — photovoltaic modules,panels,or an array. . .W ❑ 3. Is relatively free of vents,skylights,conduits,mechanical..: I_ m equipment and other suchobstructions. ACCESS 4. Does not contain photovoltaic modules,.panels or an array,or is ROOF ' Cra � : . ' a single ridge roof where the maximum edge to edge width of 3 the photovoltaic panel:system does.not exceed.33 percent.of . the ridge length. °OF a VENTILATION ''ACCESS '•ARGCESS 11011 .. ROOF: :-.1 "- [NY] R324.6.2 - Setback at ridge.. Photovoltaic arrays;shall not be : . VENTILATION located less than 18 inches(457 mm)from.a horizontal ridge. •" '_ � -1a'�-VENTILATION ' -18"=VENTILATION [NY] R324.6.2.2 Emergency escape and rescue opening. :Panels ...and modules installedon dwellings-shall not be.placed on the portion of the.roof that is below and emergency escape and rescue opening:" o A pathway not less than 36 inches(914 mm)wide shall be provided to xlsrlN DULEs the'emergency escape and rescue opening. (8)EXISTING Mo A 1: -4 ROOF ACCESS PLAN Ty Ical Attachment Metho d d EGIST�� ' co Ily RIDGE SNAP'N'RACK ULTRA RA PHOTOVOLTAIC 191-4.1' �L-FOOT AND RAILASSEM �� MODULE 3/4"MODULE SPACING BETWEEN ROWS AND - (2)S.S.304 5.0MM x SOMM. COL � Y WOOD S FASTENER. COLUMNS T P.) ER W CREW i SUNATION . ENERGY RT-MINI ROOF ATTACHMENT SUNation Solar Systems RAIL MOUNTED TO 171 Remington Blvd. RAFTER Ronkonkoma,New York 11779 (5 31)-750-9454 RAFTER . NYSE o NSTALD SHINGLE (1)LAYER ASPHALT (TYP.) 5 211 X 1 011 24" P.C. o �/ NUMBER R w 5 JOB NUMBER 02926 PLYWOOD DECKING (TYP:). SOFFIT - - WOOD FRAMING .. EXTERIOR .. .. - (TYP.) .. .. WALL ATTACHMENT TYPE APPLIED TO-ROOF"TYP" 171-011 . ROOF SECTION (TYP.) o SCALE: N.T.S.. " .. m z In z o ' SOLAR MODULE FRAM � CD � � BETWEEN MODULE R ~ � U Roof# Rafter Size/Spacing Max Span Material Layers Sheathing �100 !�'« AND COLUMNS.ILG ROWS .�, O .0 . 2"X 10"/16" O.C. 17'-0" :. P g 1 yW ss,Com osite Shin les RI ood HEIGHT ADJUSTABLE LL E♦ Z_ J W L FOOT(TYP.) END CLAM .. .. - m Cz A 6.0° ULTRA RAIL RACK � ... � m (TYP.) . 1� TYP. �- o HEIGHT OFF OF -" ROOF SURFACE Cz .. .. .. '.'RT MINI .. .. - .. .. .. .. (TYP.) - .. .. - .. .. .. - Typical.Module PEST WRAP CUT . Side Profile .. .. AWAY FOR .. :. .. _ .. .. .. .. .. CLARITY CLIMATIC AND GEOGRAPHIC.DESIGN-CRITERIA-.TABLE R301.2(1) WIND. DESIGN SUBJECT TO DAMAGE ICE BARRIER MEAN.AN NUAL SIGN GROUND SNOW TOPOGRAPHIC WIND BORNE DEBRIS INTER DE SEISMIC ECATEGORY DESIGN. `TEM ERATURE REQUIREDNT FL AZARD IR FREEZI INDEX EMPERATURE SPEED(MPH.) SPECIAL WIND ZONE WEATHERING .FROST LINE DEPTH .TERMITE' UN REQUIRED';: , OOD.H A FREEZING LOAD EFFECTS ZONE M O S" U MODERATE SEE PLANS" ' 20 PSF 140' B YES 2 B SEVERE'. 3'-0' 15 DEG 'NIA 599 51. HEAVY• EXAMINER STRUCTURE y FT ITI o - Enphase A/C Branch Circuit t RK P .. (YP) UTILITY SERVICE Enphase Microinverter(typ.) — - .�. Existing N COMBINER PSEG Utility Meter SUNATION, Account#-9682026901 M-'98306515 ENERGY Module J-Box(typ.) ` PANEL Meter# 12o/24ov. • � SUNation Solar Systems • - - SUPPLY SIDE CONNECTION - 171 Remington Blvd. Ronkonkoma,New York 11779 PV Module(typ.) (631)-750-9454 NYSERDA EGC Attached To Rail(typ. INSTALLER ) 20OA 1 A355 J MAIN NUMBER -CONDUIT AND CONDUCTOR SCHEDULE ENPHASE"GATEWAY JOB NUMBER _ (No loads,monitoring only) 5 ' TAG CONDUCTOR CONDUIT RUN.' GAUGE QUANTITY TYPE: SIZE LENGTH 2P20A 2P15A 02926 TYPECircuit#1 E phase Getaway EXISTING EXISTING.ENPHASE BRANCH CIRCUIT#1 70A MAIN , 2P20A Circuit#2 EXTENDED ENPHASE BRANCH CIRCUIT#2 1 Enphase Q-Cable 12• 6 N/A N/A . 15, .: 2P20A ' EXISTING ENPHASE BRANCH CIRCUIT. I I I Circuit#3 2 Type NM 10 6 N/A , N/A 30 I I I 3 HWN-2 10 6 PVC SCH.80 1.25" 15' PROPOSED ENPHASE BRANCH CIRCUIT#4 C?cut#4 IQ Combner Sense. GC 8 1 PVC SCH.80 1.25" 15' .' EGC G SENSE M"O ngon! G G PROPOSED. ' 2 3 ENPHASE A/C SERV CIE Ln 1. Enphase Q Cable N/A 15' ROOF ATTIC EXTERIOR IQ COMBINER DISCONNECT PANEL O " d 12 2 N/A N T O 2 TYPe,NM 10: .' 2 N/A N/A : . 30' ENCLOSURE— SERVICE TED } ti 3 HWN-2 10. 2 PVC SCH.80 1.25":: 15' MIN.60A N Z to �" M AIC IN 22k 4 HWN-2 4 3 PVC SCH.80 125" 10' U " O (D c :. O GC 8 1 : PVC SCH.80 1.25" 10' ExrEaloa BUILDING a .?� co. . . 5 HWN-2 3 .:' 3 PVC SCH.80.. 1.25 10.' . ELECTRODE: � x � 0 6 EC 4 1 N/A N/A 10' LL E "� cis _ — Cz J . Qty. Qty. Maximum AC Operating Current " Y Circuit# PV Module Y• Micro-Inverter � Y• P 9 w Enphase, c 1 ; SN20-72MBE-390V 12 P 12 : . 14.52.A CO m SN20.72MBE-390V 8 :: Cr 2 Enphase IQ8PLUS-72-2-US 13 15.73 A ' a SL65-54BHJ-400V .5.: Cz 0 3 SN20-72MBE-390V 8 Enphase IQ8PLUS-72-2-US 8 9.68 A 4 SL65-54BHJ-400V 12 Enphase IQ8PLUS-72-2-US 12 14.52 A E I 1 Maximum:AC Operating Current(Total)' ' 54.45.A I ONE-LINE DIAGRAM • • • , • LABEL LOCATION: LABEL LOCATION: EGIS MAXIMUM AC OPERATING• -- SOURCE CIRCUITS:, 1 AT EACH ACI DISCONNECT,COMPLETE VOLTAGE AND •• MAIN DISCONNECT PANEL: 1 AT EACH AND AT BUILDING MAIN SERVICE (rn , CURRENT VALUES ON DISCONNECT LABEL SC F APP LE. DI ONNECT I LICAB � T • •. - NEC 2017 690.54%NEC 201:7690.13(B) NEC 7 7 �• CI 201 05 10- . . D -• -• - • - -Service Disconnect • Yb Y, ELMEL ECTRIC SHOCK.HAZARD NOTE:ATTENTION STICKER GETS PLACED ON UTILITY METER IN ADDITION TO DO NOT TOUCH TERMINALS Service - T THE BUILDING MAIN SERVICE DISCONNECT. TERMINALS ON BOTH THE LINE AND • LOAD SIDES MAY BE ENERGIZED h s - Iding is e'nipped ith an IN THE OPEN POSITION Located Service Irtt ca acted Electric Power SUNATION. ProdU io b aurce ENERGY PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE :WHENEVER �)��; 1�1 T {:i:: {(fit �'E T H I.� T•��,�_ SUNation Solar Systems .. - - _ SaurceTt, e. 171 Remington Blvd. Solar P'h'otovolt,atc Ronkonkoma,New Y6rk11779 , (631)-750-9454 4sca•necti L'caed Inte+oc &asam®f: Garage. E erio IN S INSTALLER 4355 o +de INSTALLER Ff 91de' Other oca e : NUMBER SUNation a r Sy ,ems SOLAR =YST EQ'UIPPE JOB NUMBER 631-7i50z9454 �s• sunat+onYco �PII►NO MIN D®'V�(N 02926 TFJRN RAPID SHUTDOWN SWITCHTOTHE "OFF'PosrhoN TO PHOTOVOLTAJC SYSTEM SHUTDOWN PV SYSTEM RAPIDUIPPED WITH ANDREDUCETHE.' SHOCK HAZARD SHUTDOWN INARRAY LO : . ' T N r \ .. ... -> LO .. Z V _ -. ..- O Q U � N LPL. E Cz z Z � J � W Y cn _ m � m Q' S= ' O E2- 1 • PV LABELS sr{x� Y \`�.(� {a.' t ,Ts.,t• .� • _ _ A t �Y-�`>� R: II ��j:7'#i' r,o-lr.,�,',.��, .. r t�� � �i�!Y'��'T' Fv .`Fi~f tr� F'' ,-' •� - -- of K i 1r f ' �+i� 1111 1Ir I' F �lllfl(IIIIIIIIIIIINIIIlRllfl1111�1(Illillllll}II{iflllllllil� '" -��, - i r z �'.+>.i"+� :.:. .� \ .,. ``• lw �_,�•�� �r`yc .,mot•- IMI .•.�a-. `�` ��a„'s>.'. -s. �. w •'� .�_ .c.:.-;I m a,. 'e�'a�"'' �" � � �.' ��sty�,`a" c. ���� .Yi• "'wrf" rb - 3'•.;'M,. �,� ��.�a r" t. � -Q �� 1 �""�^m : �•i' 7r� ''',� T''fi` ti� �, ',; t.«'.2-�'j'S�'?e+Si wu.✓. :ue+,;�' ,,.... r4:a .._" ...f -"� t-'=i ni• y',� i''!Y r �\ �. . 6 1 ua�•k�4;,n. `.t.''..:-..„;a a °-�..+s.u*':�..;° �'�'�•.�° �� .: •�'r W.�,,.„ .'"mow.,","'.. ';r?�*c` �� =._a '�,±s'. ..t- a -`.� >s.." �v%w •,'c...�..• C"� y"-" .,,aw�-'e..s.�� ��_. �3-.q,fi,..,_.. .._.. �.c, c .,.. MISS—! /i- > wF '."�. 4t• T -»Kx !} „.F�. �=�"`MF vl.ar,,. .� r,.. s - :'{. __ '..'+w'a,.'. i4 w,.Y.:3P_ x, - ,..,''�.'. �. , •. :. ,.. ., : .. .�=:�'., 'T C'b'"" y.. m.,k. - .. ..+".:-.. .� .a,•.,. a ... �,_ i'>, S �Syr-"� u` a # -' ."•, 46 !,w' 'S ',*.w«'• .;. .,,..' ?'s� ",.:+X'"�r '.'• - , E: .€ =.++ir s ys ..5� M1R 1 D, 11"77- ��. .a;rt �'?. ; 'ems i��k v'"� � �,1 � "•s., ,ear b :t: 1 1 • 1 • 1 1 • • a rs �a �tV Y {ems T ,I a0l�• -Y ��: � ■, to -• rr 1 ^I�F� �� '1 ., r� j' r � 1. ■■ H s • •• � • IS V 3 Q� � A5 teS 256 Orinoco Drive Suite A Bri htwaters NY 11718 : laii ing& I Oi5gl (631)665-9619 May 20, 2024 Town of Southold Building Department artment AMEND '�"�• 54375 Rt. 25 s' Southold, NY 11971 Re: Brienbaum Residence 740 Poquatuck Lane Orient, NY Proposed 6.8 KW PV Rooftop Solar System added to 10.92 KW PVSystem To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 140 mph wind load and 20 psf snow load without overstress, in accordance with the following: The 2020 New York State Uniform Fire Prevention and Residential Building Code; Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020 National Electric Code including ASCE7-16 If you have any further questions, do not hesitate to call. � C L K OG/0� (P , RA OF N� r 0 0 HI EII m g oil iiiiiiimimmi OHIO I 11�10 � � � ° o � °0 111111111 11f�111f�1f1�1ll�flflllllf�INllllll�if111 �I�llfl��illl� f�f��fll�i�flf�8�I�11UINIGI� 111111111li81111111I1111111111811111111NIMI 011811111111i 1111I111i11118111f111111118 1111i11111f111i11 1111 III�i1011111liifIID Iffy 11fIIIIIIIIIillgl�l 11 i11111 i111111111111WIN 11111111111II1111 Hill 1�111 1!11811111I1181 111111 I1 81111 0 IIHIM11111 Hill Hill li11m111111111111i 1811 11010111HIi1�lll11f8111i11111 d8111111�110 s 0 11IB0 111 l �1 f1I I 11I11111118118�18118IN1MI1f11 N1pII�H18��iIhB I8 G fl 1 � a1 8 I 1III 6 11 f! I► IBM p1�ffll�1 1111 I Nf � Iy►118iIp 11111 1af1 1 1118n888881I�lII 18l81 1� 18 11188No l BD I �I 1Itllllllllu9�I BJulll I B�U � lbiHm1If 88AIBiimiii 1IM II III 1 �111111111N 11m1111181iiimiiilH811 11I HI� 8 1 �m®m®�OP�11�1111���1 �11II lini1111111 �® ®IB0�111�1011s1�1®81®� I===IMEREN EERM111111101 HEM I®1 81111®MN mom= o BOOimumoflliilO �111� FEATURES /25t,- � Up to 25%more energy yield l due to the back side power generation Low LID mono PERC I Bloomberg i CIP ou bifacial cell technology — CE s_ c s Excellent performance under low light conditions Cloudy days,mornings and evening WARRANTY ®-YEARS PRODUCT WARRANTY Enhanced External Load/Impact -YEARS LINEAR PERFORMANCE WARRANTY Snow Load:5,400 Pa Wind Load:2,400 Pa O" µ j PID Resistance T Enhanced Potential Induced Degradation 9— Resistance 8171 Fire Safety Spread of Flame Class A f� Burning Brand Class C o, s o s zo �s so _ — 0 S•Energy Industry Standard N G �', o -a o�96.0 6, 6 0, c -o o •0 0 00 0 -.�].� ' - o `y� a G II Q99��C�GL� I �' °'e9,NJ�1, F�ff W��- � � 4��1%J��9 l/E�°77 Irk e�9°�°-�°GX34= '5�° 6 ''�' ' ° �i �° •°.t- ..r..... ✓ ■ vv) v1 9 Sy s$ J-Cnery� 19500V MonocrystallinePVModule 390W • 395W 40OW • 405W ELECTRICAL CHARACTERISTICS STC-oiraafae°el:000w/m2;n,aaeiet—P.e m2sc.ArA=1.5) ','•( SL65-54BGJ/BH1-39OV. '' SL65=54BGJ/BHJ-395V . ,1, SL65-54BG1/BHJ-400V .;I . SL65-54BGJ/BHJ 405V' Rated Power(Pmax) 390W 395W 400W 405W I Voltage atPmax'(Vmp); 30,82V _ 31OOV 31„17V:' ? Current at Pmax(Imp) 12.66A I 12.75A 12,84A 12.92A Warranted Minimum Pmax 39OW ; 395W 40OW 405W Short Circuit Current(Isc) I 13.50A 13.59A 13.68A 13,78A I Open Circuit Voltage(Voc) 36.84V i. 37,03V, 37.20V' 37,36V Module Efficiency 19.97% 20.23% 20,48% 20.74% Operating Module Temperature' -401rto+85'C Maximum System Voltage 1,500V Fuse Rating - -.— 30A. Maximum Reverse Current 40.5A Power Tolerance --...._.___.___•. - - __ _ - _... .�0.^+SW----_'_--•-----�-......._..._._.__..�..,.-.............. - - - - _ ELECTRICAL CHARACTERISTICS back side power gain(referenceto400W front)- *Bifacialityt7o% Pmax. ;- azow.:. 44oW..:_ -,4601N - . - 48.6W,' _ SDOW _ Voltage at Pmax(Vmp) 31,20V 3t.20V- I 31.20V 31.30V 31.30V _.._... �- - - - - - _ - CUrrent�atP max(Imp) '..;:�:;' '.'13.47A 1''"' -.. -14.72A.:.-, :i ;.: 14,76A:.;;:" } _15.35A '' (:' ...15:99A- Short-Circuit Current(Isc) 14.36A 15.05A 15.73A 16.42A 17.10A Open.Circuit Voltage(Voc) ' j. "' 37.20V . ._ 37,20 '- 37.20V 37.30V 1 37.30V Pmax gain i 5% 10% 15% 20% 25% MECHANICAL CHARACTERISTICS 1134 [44.65] Solar Cells I Monocrystalline Bifacial Cells 18201 mm - Numberof Cells_ 54Hatf.Cells.(6x18Ma1dx) Dimensrons� 1.722 x 1,134 x 30mm ©©©© N Front l Rear Load •5,400Pa/2,400Pa M.A..I.hole Weight I21.4k9 ©®©© Glass_- 3.2mm High-Transmittance Low Iron Tempered Glass ®©©© BackSheet; -'Transparent Back-sheet(White/Black) �llll10ll�WL11 :ao Hole qm Frame''::` Anodiied'Aluminum'Fiahie(Silver/Black). ©©®© IP67 with 3 bypass diodes ©®©® Output Cables PVWire(PVf+.I,12AWG'(4mriM,Cable Length.:500mm,' *cable length can be cbstorri¢ed. Connectors MC4 Original,Compatible ©©©© TEMPERATURE CHARACTERISTICS ©©MUM©©W11111116EA'.1n.p hale Temperature ccefl�cie"r1Yof lsc' 0.048%/`0 - _ 1093 I t�,Tempe�rature—co_e(ficienttif Voc. -0.270%/b unit:mm ! -- - - .. ._. (inch] TempeiaturecoWficiento#power:'' 0.320%/t NOCT(rair 20b9 Irradiance 800W/m2:Wind,lm/s), .45±212 " PACKING CONFIGURATION` g g :—Container,-. �- - - 20' 40 FModules Per Pallet 36pcs 36pcs_ t - - --. - — PalletsPerton diner 6pallets 24pallets IrMlodulesPerContainer:. ' '216 mpcs . i' 864pcs ' - '° °mwmb •° °° '° �°mwm 41 °° Pmax measurement tolerance;±z,5r Installation instruction supplied with the module must be duly followed.For further information which is not S-Energy uses triple A class simulator. REMARKS Specification subject to change without prior notice. NOTES mentioned on installation guides or directions,please S-Energy reserves the rights of final interpretation. contact to our technical service department. E-mail:Inquiry@s-energy.com , • r ENPHASE. m IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- defined microinverters with split-phase power conversion capability to convert DC Easy to install. power to AC power efficiently.The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors 55nm technology with high speed digital logic and has super-fast response times Power Line Communication to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components energy systems. • Faster installation with simple two-wire cabling Enphase !! a High productivity and reliability �r 25 ' Produce power even when the year I!,mi1;d grid is down • More than one million cumulative Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability hours of testing Microinverters integrate with the Enphase IQ standards with more than one million Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure of up to 25 years. • Optimized for the latest high- powered PV modules Microgrid-forming CERTIFIED Complies with the latest SAFETY Ilr� advanced grid support Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for I08 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed connectors. according to manufacturer's instructions. Configurable to support a wide range of grid profiles ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 microinverters, Meets CA Rule 21(UL 1741-SA) and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements I08SP-DS-0002-01-EN-US-2021-10-19 IQ8 and IQ8+ Microinverters INPUT DATA IDCI1: .1 1" Commonly used module pairings' W 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currentz[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT 1 A' .1 1'• Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' v 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit4 16 I 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 I 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -400C to+60°C(-40°F to+140°F) Relative humidity range 4%to100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm MY)x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-DS-0002-01-EN-US-2021-10-19 f SERIES 100 FLASHED L FOOT S'napNrack Rosidentlal ' • • Systems- The line SnapNrackmountingt _ ors= s� : = ;; .�:•T� p e of solar ed to reduce total s stems is designed �.� y g installation costs. T he system features �-:� ��- � ��, -r• �;��.:.> ��.; a:l` � � L ; iy�.'� 'env'.teiF.•��i �a:.:.w:-�{,Y^T'�a4•"�"..-. technical innovations �� proven on more than 20OMW of solar projects to simplifyN `- = _M= installation and reduce costs. _, 1 Flashed L Foot Simplified. SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over the life of the system. The Flashed L Foot provides a single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles. The L 1) 'Locate the rafter and drill the'pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3) Set the flashing and attach the L Foot • 1" slotted bolt connection • 1" spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at • No Cutting of shingles www.snapnrack.com/contact SnapNrack- Patent Pending pd Hounung %Yoftma I 1 Flashed L Foot Kit Assembled(1°spacer sold separately) Flashed L Foot Kit Parts(1"spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions rSNAPNRACK CHANNEL NUT r-SNAPNRACK 92 DEGREE L-FOOT,CLEAR 5/I618 FLANGE NUT G� 5/I618 X IIN BOLT WTTH SPLIT LOCK WASHER -SNAPNRACK COMPOSTIION FLASHING Ci 3.13 `SNAPNRACK L-FOOT BASE - is SnapNrack Flashed Foot Technical . ta Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 Ibs Design Uplight Load 200 Ibs Uplift Design Ultimate Load 1,000 Ibs Uplift Warranty 10 Year material and worksmanship SnapNrack- FV R`j�eunUng Systems (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. rn)rnz h%/c.—NI—L,PV rnniintinn rx,ctam All rinht�ra—r—H r SERIES 100 UL ROOF SnapNrack Solar Mounting Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar ' installations. L-%� �:�~-.. . w.•-;�;,:�..;T:a=.��,��'��..Y�:,.� Pitched Roof Arrays Simplified HE F-—- The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) ;;.......... ......�-��:�k`�:;;, :•,_.���;�•--•.•�.• module installation system.Series 100 UL is Listedto the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware. The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building" Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material'for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) U • Class A Fire Rating Type 1 and 2 modules p` LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Split-Lock Washer Bolt with Split Splice Insert Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top v Bonding - Base SnapNrack Mid Clamp SnapNrack Bonding ' SnapNrack Bonding Adjustable End Stainless Channel Nut Clamp Bottom Bonding Stainless Hardware with Bolt with Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding `Hasher Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG Copper Wire — SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF • MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave 1� UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF IF IF IF F SnapNrack Bonding Universal End Clamp SnapNrack V�` Bonding Standoff Clamp Assembly A SnapNrack Serrated Stainless 1M SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut ,• Flange Nut Steel Flange Bolt SnapNrack Stainless SnapNrack �• 92 Degree Flange Mill Finish L Foot Bolt Standoff o SnapNrack SnapNrack r All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole i SnapNrack Base Shown) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Fact Patent Pending SnapNrack Series 100 UL Technical Data Materials - 6000 Series aluminum - Stainless steel - Galvanized Steel and Aluminum Flashing Material Finish - Clear and black anodized aluminum - Mill Finish on select components Installation -Quick and efficient mounting -Adjustable hardware to ensure clean and level finish -All components bonded to ground with integrated bonding features Calcs.& Certifications - Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification - Class A Fire Rating Type 1 and Type 2 Modules - Stamped Structural Engineering Reports for all 50 States Grounding - SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty - 10 Year material and worksmanship(download full details at snapnrack.com) Snap!"I 'lrack- soln? P-3ounting soiiltioms (877) 732-2860 www.SnapNrack.com r.* Printed on recycled paper using soy based inks.