Loading...
HomeMy WebLinkAbout48071-Z O�S�FfQ TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT. (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 48071 Date: 7/15/2022 Permission is hereby granted to: Tavani, Michael 2 Northside Piers Ph 1 Brooklyn, NY 11249 To: Install generator as applied for. Replaces BP#43570. At premises located at: 50 Lighthouse Rd., Southold SCTM #473889 Sec/Block/Lot# 55.-1-2 Pursuant to application dated 7/15/2022 and approved by the Building Inspector. To expire on 1/14/2024. Fees: PERMIT RENEWAL $117.50 Total: $117.50 Building Inspector 1 / TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE SOUTHOLD, NY x BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43570 Date: 3/19/2019 Permission is hereby granted to: Tavani, Michael 2 Northside Piers Ph 1 Brooklyn, NY 11249 To: install generator as applied for. At premises located at: $ I a� \ 10 n�&�1 _ 4 50 Lighthouse Rd., Southold �f 11 SCTM # 473889 Sec/Block/Lot# 55.-1-2 Pursuant to application dated 3/19/2019 and approved by the Building Inspector. To expire on 9/17/2020. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO -RESIDENTIAL $50.00 Total: $235.00 Buildin nspector oF soulyolo TOWN OF SOUTHOLD BUILDING DEPT. courm NF'` 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING ] FINAL 6C/.( [ ]. FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ] RENTAL REMARKS: t Ole' DATE I ?-0'L?/ INSPECTOR AAMF WOOF glryj�vv FIELD INSPECTION REPORT DATE COMMENTS _1Z, FOUNDATION (1ST) ------------------------------------ conC FOUNDATION (2ND) V1 z � 0 a � cn t ROUGH FRAMING& a PLUMBINGvi— r INSULATION PER N.Y. STATE ENERGY CODE V O FINAL AD ITIONAL CO ENTS 91 17 , ccs C d2a la3 it —• O l g z m Cb � o x x d r� H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets-of Building'Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 C?��` Suryey Southoldtownny.gov PERMIT NO. `� �/�J Check Septic Form .�► O rD.E.C. Trustees Trustees ( ` C.O.Application Flood Permit Examined 14 120', 9 2�1� Single&Separate Truss Identification Form Storm Water Assessment Form ' " Contact: Approved 3 ,20-1a '�® ® a>r I Disapproved a/c // Q A -A (j Dhon Expiration ,20 Bui g ector APPLICATION FOR BUILDING PERMIT Date , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining-premises or public streets or areas, and waterways. c. The work covered by this application may not be.commenced before issuance`of Building Permit. d.Upon approval of this application, the Building Inspector,will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the'Building Department•for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Soutfiold, Suffolk�County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions,.or alterations or-for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant,or.name,if a corporation) (Mailing.address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. L9 ti of land on which proposed work will e done: House Number Street Hamlet County Tax Map No. 1000 Section Block.. . 1 " `' Lot CZ Subdivision. , Filed Map No. Lot i 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a: Existing use and occupancy C-'ifyl 2Q b. Intended use and occupancy � p j 3. Nature.of work(check which applicable): New Building/ '.jdyr�_ tion Alteration Repair Removal Demolitio, __.a 4 bthdr:lwnr - eN_'=CLAD F, _ Q+ :` (Description) 4. Estimated Cost Fee ( , (Tobe p�.d�o filing this application) 5. If dwelling, number of dwelling units Number of dwelling un'i'ts on each floor If garage, number of cars 6. If business, commercial or mixed"occupancy, specify nature and exterif'AC ach type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height . .Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front :Rear. Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction.violate any zoning law, ordinance or regulation? YES NO V/ 13. Will lot be re-graded? YES NO ✓ Will excess+fll'be removed from premises?YES NO ✓ ! 14. Names of Owner of premises Address Phone,-No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this.property.within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES,.SOUTUOLD TOWN TRUSTEES &D.E.C. PERMITS MAY 7B ,REQUIRED. i b. Is this property within 300 feet of a tidal wetland?* YES NO * IF YES,D.E.G. PERMITS.MAY BE-REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. r 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES,PROVIDE A COPY. I. I STATE OF NEW YORK- SS: ORKSS: COUNTY OF') j l j f. 1 C'I` being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contract ,Agent, Corporate Officer, etc.) of said owner or'owners, and is razed to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this _"' day of MQYC 1_20LCt,fN otary Public I HAL&Y WYER Signature of Applicant NO RY PUBLIC,STATE OF NEW YORK NO.01DW6306900 QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2 W Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: House No. 1� ,,^ -- nn Street Hamlet Owner or Owners of Property: pl ae(�-t' :TawainA Suffolk County Tax Map No 1000, Section �S Block D Lot (D Subdivision Filed Map. Lot: Permit No. :R,5j-0Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: I / Request for: Temporary Certificate Final Certificate: (O (check one) Fee Submitted: $ Applicant Signature ��t1FF01,��o BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 `� • Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger.richert(o-)town.sou thold.ny.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: T�r�y (.�Ci� Date: — Company Name: Name: - � l License No.: t q 1 _ fJ email: ' G c �ti� Address: ` 22�- 5 �- �� � - 140 Phone No.: JOB SITE INFORMATION: (All Information Required) 1 0 Name: Address: Cross Street: Phone No.: -��, - �� p • BIdg.Permit#: — email: Tax Map District: 1000 Section: Block: CA Lot: 0, BRIEF DESC I IN '' RI Please Tint early) Circle All That Apply: �-�-- Is job ready for inspection?: �YES� NO Rough In Final Do you need a Temp Certificate?: YES /WO Issued On Temp Information: (Ali information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection FormAs ���� - \ •o. o c [,! oyn c 6�3.T c� V�6 Gro 6 Soy 0��. y 25 y 0 ti 0 S 5 i � •5 � 9� APPR VED AS NOTED GENE RAC® DATE:3 B.P.# iA` FEE: BY. GUARDIAN® SERIES 16/20/22 kY� NOTIFY BUILDING DEPAR NWTesidential StandbyGenerators 765-1802 8 AM TO 4 PM FORTH FOLLOWING INSPEI-T�!,)NS: Air-Cooled Gas Engine 1. FOUNDATION - TWO. REQUIRED FOR POURED CON.;RETE ' G - FRAMING & PLUMBING INCLUDES: 3. INSULATION • True Power"" Electrical Technology 4. FINAL - CONSTRUCTION MUST Standby Power Rating BE COMPLETE FOR C.O. G007036-1,G007037-1 (Aluminum-Bisque)-16 kW 60 H7 • Two Line LCD Multilingual Digital r Model G007035-1 (Aluminum-Bisque)-16 kW 60 Hz Evolution-Controller(English/Spanish/ALL CONSTRUCTION SHAL�cgfgojg-1,G007038-1 (Aluminum-Bisque)-20 kW 60 Hz French/Portuguese) REQUIREMENTS OF THE CQIU --2,G007042-2(Aluminum-Bisque)-22 kW 60 Hz • Two Transfer Switch Options Available: YORK STATE. NOT RESPONSIBLE FC`fi 100 Amp,16 Circuit Switch or DESIGN OR CONSTRUCTION ERRORS. 200 Amp Service Rated Smart Switch. G See Page 5 for Details. ! U • Electronic Governor • Standard VU-Fi- Remote Monitoring n��p �/ • System Status&Maintenance InQQ L"FzD Q1cayyjTH ALL CODES OF • Sound AttenuatedEnclosurd`EW YORK STATE & TOWN CODE Flexible Fuel Line Connect�r S REQUIRED AND CONDITION OF- 0GENERAC'- • Natural Gas or LP Gas Operation SOl1THOl TOWN 7RA k • 5 Year Limited Warranty • Listed and Labeled by the Southwest Research InstitulftftQCUl V installation as close as 18"(4 } s#��t�re -- ��ttltftQCUl V or C L US � { *Must be located away from doors, windows, and c - us LISTED �VI intakes and in accordance ^*h r^^ https://assets.swii.orgllibraryIDirectoryOUstedProducts/ Note:CETL or CUL certification only applies to unbundled units and units Constructiontndustry/973_DoC_204_13204-01-01_Rev9.pdf packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Generac's O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible.Generac's G-Farce engine This state-of-the-art power maximizing regulation system is standard on lineup offers added peace of mind and reliability for when you need it the most.The all Generac models.It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions. electronically torque-matching the surge loads to the engine. Digital voltage regulation at±1%. O TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5%Total Harmonic Distortion for utility quality power.This allows network provides parts and service know-how for the entire unit,from the confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are ✓ PROTOTYPE TESTED ✓ NEMA M01-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.. 0 MOBILE LINK— REMOTE MONITORING: FREE with every Guardian Series Home OCCUPANCY I OR standby generator.Allows you to monitor the status of your generator from anywhere in the world using a smadphone,tablet,or PC.Easily access information such as the current USE I S UNLAWFUL operating status and maintenance alerts.Connect your account to your authorized service dealer for fast,friendly and proactive service.With Mobile Link,you are taken care of before efWZAL WITHOUT CERTIFICATE INSPECTIUm REQUIRED = GENERAC -1 �A� � . I CUPANCY r—(PROMISE . •xaameaumromrsao-�,.i `. GENERAC® 16/20/22 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating the output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution"' Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of five(5)seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. t � GENERAC 16/20/22 kW Features and Benefits Installation System • 1 it(30.5 cm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life. Remote Monitoring • Ability to view generator status Monitor your generator via your smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due • Monthly report with previous month's activity. Detailed monthly reports provide historical generator information • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery • Weather information Provides detailed local ambient weather conditions for generator location GENERAC® 16/20/22 kW Specifications Generator Model G007035-1,13007036-1, 13007036-1,G007039-1 G007042-2,G007043-2 G007037-1(16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity(LP) 16,000 Wafts' 20,000 Wafts` 22,000 Watts' Rated Maximum Continuous Power Capacity(NG) 16,000 Wafts` 18,000 Watts' 19,500 Wafts Rated Voltage 240 240 240 Rated Maximum Continuous Load Current—240 Volts(LP/NG) 66.7/66.7 83.3/75.0 91.7/81.3 r Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 70 Amp 90 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight(lb/kg) 409/186 448/_263 466/211 Dimensions(L x W x H)in/mm 48 x 25 x 29/1 18 x 638 x 732 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" 67 67 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test-low-speed_exercise mode" 55 55 57 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/Cast Iron Sleeve Valve ArrangementOverhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 VDC 12 VDC 12 VDC Oil Capacity Including Filter Approx.1.9 qt/1.8 L Approx.1.9 qt/1.8 L Approx.1.9 qt/1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas fts/hr(ms/hr) 1/2 Load 218(6.17) 204(5.78) 228(6.46) Full Load 309(8.75) 301(8.52) 327(9.26) Liquid Propane ft3/hr(gal/hr)[I/hr] 1/2 Load 74(2.03)[7.70] 87(2.37)[8.99] 92(2.53)[9.57] Full Load107(2.94)[11.11] 130(3.56)[13.48] 142(3.90)[14.77] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(7-13 mm Hg)for natural gas,10-12 in water column(19-22 mm Hg)for LP gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG) Controls Two-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons:Auto Automatic Start on Utility failure.7 day exerciser. Manual Start with starter control,unit stays on.If utility fails,transfer to load takes place. Off Stops_unit.Power is removed.Control and charger still operate_. Ready to Run/Maintenance Me ssages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable(Brownout Setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard Run/Alarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection_ Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Faull/Incorrect Wiring Protection Standard Common Extemal Fault Capability Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator maybe higher depending on Installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability Is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajoule content,ambient temperature,attitude,engine power and condition,etc.Maximum power decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level;and also will decrease about 1 percent for each 6°C(10"F)above 16°C(60°F). GENERAC® 16/20/22 kW Switch Options Limited Circuits Switch Features Model _ _ G007036-1(16kW)-_ • 16 space,24 circuit,breakers not included. iCu�o Poles_ -_ __- Current Rating(Amps) _ _ 100 _ cc • Electrically operated,mechanically-held contacts for fast,positive ,voltageRabng(vAc>- �_ 120/240,10 connections Utility Voltage Monitor(Fixed)* • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 80% resistive. -Dropout 65% • 2-pole,250 VAC Contactors. Return to Utility' approx.l5 sec of • 30 millisecond transfer time. Exercises bi-weeklyfor 5 minutes'- - _ - ^ Standard • Dual coil design. ETLorULLSte d Standard J • Rated for both copper and aluminum conductors. Total Circuits Available -_-_ __ 24 • Main contacts are silver plated or silver alloy to resist welding and sticking. (Tandem Breaker Capabilities _ _ _8 tandems ) • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor Circuit Breaker Protected Available RMS Symmetrical 10,000 mounting flexibility. Fault current @ 250 Volts • Multi listed for use with 1"standard,tandem,GFCI and AFC(breakers from *Function of Evolution Controller Siemens,Murray,Eaton and Square D for the most flexible and cost effective Exercise can be set to weekly or monthly install. Dimensions W+ Height Width Depth H1 H2 Wi W2 in 26.75 30.1 10.5 13.5 6.91 H2 H+ mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug DEPTH tw2 1/0-#14 2/0-#14 210-#14 Service Rated Smart Switch Features Model G007037-1(16 kW)/GO07039-1(20 kW)/ • Includes Digital Power Management Technology(DPM)standard. G0o7o43 2(22 kW)_ t • Intelligently manages up to four air conditioner loads with no additional iNo.of Poles 2 hardware. Current Rating(Amps) 200 Rating a (VAC) 120/240, • Up to eight additional large(240 VAC)loads can be managed when used in IVolta9-- - ---- -- --- - ---- -------- 10 ---- conjunction with Smart Management Modules(SMMs). Utility voltage Monitor(Fixed)' a -Pick-up 80% • Electrically operated,mechanically-held contacts for fast,clean connections. -Dropout 65% • Rated for all classes of load,100%equipment rated,both inductive and LReturn to Utility' approx.13 sec resistive. Exercises bi-weekly for 5 minutes' Standard • 2-pole,250 VAC contactors. ETLoruLListed Standard • Service equipment rated,dual Coll design. Enclosure Type NEMA/UL 3R • Rated for both aluminum and copper conductors. ;Circuit Breaker Protected _ _ _ 22,0.00_ • Main contacts are silver plated or silver alloy to resist welding and sticking. Lug Range 250 MCM-#6 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor *Function of Evolution Controller mounting flexibility. Exercise can be set to weekly or monthly Dimensions W+ 200 Amps 120/240,1 e Open Transition Service Rated Height Width Depth H1 H2 W1 W2 H2 H+ in 26.75 30.1 10.5 13.5 6.91 mm 679.4 1 764.3 266.7 343.0 175.4 DEPTH �W2 GENERAC® 16/20/22 kW Available Accessories Model# Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitori the LP tank's fuel level is an important step in making sure the generator is ready to run during an unex- G007005-0 V-Fi LP Fuel Level Monitor Ing pected power failure.Status alerts are available through a free application to notify you when your LID tank is i in need of a refill. ?G005819-0 26R Wet Cell Battery Every standby generator requires a battery to startthe system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact@). G007101-0 Battery Pad Warmer 'The pad warmer rests underthe battery.Recommended for use if the temperature regularly falls below 0 i oF(-18 oC).(Not necessary for use with AGM-style batteries). i G007102-0 h Oil Warmer IOil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below 0 oF 'I (-18-C). i G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only I in climates where heavy icing occurs. Auxiliary Transfer Switch '•The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you G005621-0 Contact Kit may not need.Not compatible with 50 amp pre-wired switches. !The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a sleek, 'Fascia Base Wrap Kit i G007027-0-Bisque contoured appearance as well as offering protection from rodents and insects by covering the lifting holes (Standard on 22 kW) located in the base. G005703-0 Bisque 'Paint Kit If the generator enclosure is scratched or damaged,it is importantto touch up the paintto protect from future I I - corrosion.The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.! G006485-0 4Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine main_� tenance on a Generac automatic standby generator. Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power', Smart Management Module . G007000-0 management capabilities.It provides additional power management flexibility not found in any other power (50 Amps) management system. Dimensions & PCs 1218 mm 637 148.0 , Model UPC [2511 i-l- g G007035-1 696471074161 0 G007036-1 696471074154 G007037-1 696471074178 727.2 mm lhpt�� [VA N] qo�� G007038-1 696471074185 G007039-1 696471074192 G007042-2 696471074208 10 G007043-2 696471074215 it 646 mm 1232 mm - 1 (48.5 hi LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.Referto installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC® Generac Power Systems,Inc. - S45 W29290 HWY.59,Waukesha,W1 53189 - generac.com 1 @2018 Generac Power Systems,Inc.All fights reserved.All specifications are subject to change without notice.Part No.10000000194 Rev.J 12/05/16