HomeMy WebLinkAbout47650-Z -VV-'
0ogpFF01,��0 Town of Southold 5/12/2022
P.O.Box 1179
N � 53095 Main Rd
Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 43066 Date: 5/12/2022
THIS CERTIFIES that the building AS BUILT ALTERATION
Location of Property: 355 West Ln,East Marion
SCTM#: 473889 Sec/Block/Lot: 38.-6-2
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
3/11/2022 pursuant to which Building Permit No. 47650 dated 4/6/2022
was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
"as built"HVAC as applied for.
The certificate is issued to Patton,James&Pagano,Ronald
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 47650 4/28/2022
PLUMBERS CERTIFICATION DATED
Authorized Signature
t" TOWN OF SOUTHOLD
�o�gUFfUl,t
BUILDING DEPARTMENT
y x TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 47650 Date: 4/6/2022
Permission is hereby granted to:
Patton, James
PO BOX 24
East Marion, NY 11939
To: legalize "as built" AC as applied for.
At premises located at:
355 West Ln, East Marion
SCTM #473889
Sec/Block/Lot# 38.-6-2
Pursuant to application dated 3/11/2022 and approved by the Building Inspector.
To expire on 10/6/2023.
Fees:
AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00
CO-ALTERATION TO DWELLING $50.00
Total: $450.00
Build g Inspector
of so�Ty®l
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 �Q sean.devlin(cD-town.southold.ny.us
Southold,NY 11971-0959 'QIyCOU�'��
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: James Patton
Address: 355 West Ln city:East Marion st: NY zip: 11939
Building Permit#: 47650 Section: 38 Block: 6 Lot: 2
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: AS BUILT License No:
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Service
Commerical Outdoor X 1st Floor Pool
New Renovation 2nd Floor Hot Tub
Addition Survey X Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO
Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks
Disconnect Switches 4'LED Exit Fixtures 11 Pump
Other Equipment:
Notes: " AS BUILT NO VISUAL DEFECTS " HVAC
Inspector Signature: r_N Date: April 28, 2022
S.Devlin-Cert Electrical Compliance Form
�aOF Sol/Ty� �J. O SS
—7� � 1► Y �J � • I
* TOWN OF SOUTHOLD BUILDING DEPT.
cou765-1802
INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND' [ ] ..INSULATIOWCAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[
] -FIREPLACE FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) / ELECTRICAL (FINAL)
[ ] CODE VIOLATION [/ ] PRE C/O
REMARKS: - �/j�T Y VA-6
_ r-
DATE L4 INSPECTOR
pF SOGTyOIo
# TOWN OF SOUTHOLD BUILDING DEPT.
couto, 631-765-1802
1 NSPECTION
[ ] FOUNDATION IST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ] INSULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL litIliG
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
] CODE VIOLATION [ ] PRE C/O [ ] RENTAL
REMARKS: G 1// rot. C
DATE S—lz—Z7- INSPECTOR
FIELD INSPECTION REPORT I DATE COMMENTS
FOUNDATION (1ST)
H
--------------------------------------
FOUNDATION (2ND)
z
0
cn
H
ROUGH FRAMING& 1
PLUMBING
1
r
INSULATION PER N.Y.
STATE ENERGY CODE
w
FINAL
ADDITIONAL COMMENTS
0
z
`\ m
p
H
O
z
c1o,
x
r�
H
x
d
b
H
�o�°SUFFotK�o TOWN OF SOUTHOLD—BUILDING DEPARTMENT Q
Gy` Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
�y�o• �� Telephone(631) 765-1802 Fax(631)765-9502 https:%/www.southoldtownn�gov
Date Received
APPLICATION FOR BUILDING PE MIT
For Office Use Only D M
PERMIT NO. Building Inspector: l
. MAR e 7 2022
2
Applicat oris'and forms must be filletl dut'n their entirety:.InGomplete %'
BUILDING Vcr i.
applications"will not be accepted. Where the Applicant is not the owner,,an 'DOWN OF SOUTHOLD
Owners Authorization form(Page.?) 11 be,c sha ompleted'.
71
Date:March 7, 2022
77, 77
OWNERS)OF PROPERTY:
Name:JamesPatton/Ronald Pagano o. sCTM#1000-38-6-2
ProjectAddress:355 West Lane, East Marion,-NY 1.1939
Phone#:908-672-3663 _ _ _ Email jaspat1951 @y_ahoo.com
Mailing Address:PO BOX 24,East Marion, NY 11939 _
CONTACT PERSON
Name:James_Patton
Mailing Address:PO Box 24, East Marion, NY 1_1939
Phone#:908-672-3663_ _ _ T Email:jaspat1951_@yahoocom
,DESIGN RROFESSIONALJNFORMATION.
Name:
Mailing Address:
Phone#: Email:
CONTRACTOR INFORMATION:
Name:
Mailing Address:
Phone#: Email:
DESCRIPTION OF PROPOSED CONSTRUCTION -
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
R Other Existing Air Conditioning $
Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes ❑No
1
PROPERTY INFORMATION
Existing use of property: Intended use of property:
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
this property? ❑Yes ❑No IF YES, PROVIDE A COPY.
After' Reading: The owner'contractor desi n;professianal�responsible for all drainage and storm water issues as provided by'.^.
Chapter 23b f the own Code.APPLICATION iS HEREBY MADE to the a3u0ding departmentfr`
othe issuance at a Building permit pursuant to the.Suilding Zane'
Ordinance,of the Tawn of Southold,Suffolk,County,New York and other applicable Laws;Ordinances or Regulations,;for the,construction of buildings,:,, ,
additions,alterations or for remoyal or,demolition as herein described.The applicant agrees to comply with all appllcable caws,ordinances,building,code,
housing code and regulations and to admit authorized inspectors on premises and in buildmg(s)for necessary mspections False statements made herein are
punishable as a Glass A misdemeanor pursuant to Section 210 45 of the New York StatePenal Law;
Application Submitted By(print name):J�me atton ❑Authorized Agent BOwner
Signature of Applicant: s �� Dated - j�Z--
STATE OF NEW YORK)
SS:
COUNTY OF Suffolk )
�/- M&-";: P14-71?>1 being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the
(Contractor,Agent,Corporate Officer,etc.)
of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief;and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
day of /� G�, —•2U Z
Notary Publi
JOANNE LIGUORI
NOTARY PUBLIC-STATE OF NEW YORK
PROPERTY OWNER AUTHORIZATION No. 01L16168536
Where the applicant is not the owner ®uallfled In Suffolk County
( pp ) �� Commisslon ExplM dun® 11, 203-�
I, residing at
do hereby authorize to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
Owner's Signature Date
Print Owner's Name
2
IBNG DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
T wn Hall Annex- 54375 Main Road - PO Box 1179
• at4 of so°)Vouo Southold, New York 11971-0959
4.1 � Telephone (631) 765-1802 - FAX (631) 765-9502
rogersoutholdtownny qov seand(cDsoutholdtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN N (All information Required) Date: March 7, 2022
Company Na e: AS BUILT
Electrician's Na
License No.: Elec. email:
Elec. Phone No: ❑1 request an email copy of Certificate of Compliance
Elec. Address.:
JOE SITE INFORMATION (All Information Required)
Name: James Patton
Address: 355 West Lane, East Marion, NY 11939
Cross Street: North Lane
Phone No.: 908-672-3663
BIdg.Permit#: email:jaspat1951 @yahoo.com
Tax Map District: 1000 Section:038.00 Block: 06.00 Lot:002.000'
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Air 6rd un i
Square Footage:
Circle All That Apply:
Is job ready for inspection?: O YES ❑ NO F-1 Rough In Final
Do you need a Temp Certificate?: O YESE]NO Issued On
Temp Information: (All information required)
Service Size O1 Ph O3 Ph Size: A # Meters Old Meter#
❑New Service[]Fire ReconnectOFlood ReconnectOService ReconnectOUnderground®Overhead
# Underground Laterals 1 2 H Frame Pole Work done on Service? 0 Y ON
Additional Information:
PAYMENT DUE WITH APPLICATION
L4 -7
- Goad et
N'&4 W S+0
DEPARTMEN• -OF N :: °TM ,� ���,►.
R1V�RN ADS N,Y.
4 i
10 ,I a'i rgrca q ;
TM
0
Ll
4�>/ TEST Hc!I E
i
r we Si
Lj
� c
b
Al D-,-:! Giovamvicx
Wetf
p
Ix,0, P /Pool ti
II �pp 0
. .I140
T N .5 .3S8' " 1130.0 j w O�U �•iviJcl
�m Q
SUFFOLK COUNTY HEALTH :' -ARTMENT
--- AUG 8
DATE 1973 H. D. REF.
it
- y93
The sewage disposal and water s'znply
��--- • I-1J �-,' 0 facilities for this locatic-i have been
k
inspected by this department and found
d to be satisfactory
' b i
S.5$•58,30 ".V i30. p•• Chief of General Engineers � '
Services
N.
TH
0 J �
4 J
i ► M I
I Z-111-57 / `/r4 Fir J.gW►ur�o�lttto�LT>aeAnor�ox abDmp
,�c.� ;� �y iFNd iWlWri 11 A v1OeATEO4 of
3 O r:Ducd7!Ci�414Ww. 110NC sTAi�
1 COPIES;OF THIS SU.V ; *FATUM�Q
i Ti;. LA.'D SURVEY(
EniE.:.S C SfA• Sq. 01N
f - USIDEJU0
TO B
LJ E A VA-b +•,,, ,.,.
GUA,:A;'TE:S INDICATED HEREON SHALL RUN
ONLY TO THE ,EkSO,4 FOR WHOM THE SURVEY
IS PREIA;.ED, AND ON HIS 6E11ALF TO THE
TITLE COMPANY, GOVERNMEN'iAL AGENCY#M
LENDING INSTITUTION LISTED WREON,AM
ATO TH' ASS•3NEES OF THE
LENDING INSTI.
d fYI v �� TUTIO,., L(A�ANTEES ARE NOT TRANSF
TO ADDITIONAL
OWNS, }irS�Cl.ylTitiS.Q7l SINS
y f1Nc
LA
I1
i Liceri�rd LCt1su E.IYV"eWov•'_?• .•
i, ,�.
7.
` t Rod
APPROVED AS NOT D
DATE: B.P:#
FEE: �6Y: dL
_�aNOTIFY:BUILDING DEPARTMENT AT
765-1802. 8 AM TO 4 PM FOR THE
FOLLOWING INSPECTIONS: ELECTRICAL
1. FOUNDATION - TWO REQUIRED INSPECTION REQUIRED
FOR POURED CONCRETE
2. ROUGH - FRAMING; & PLUMBING
3. INSULATION
4. FINAL - CONSTRU^TION MUST
BE COMPLETE F:;F
ALL CONSTRUCTION S.;ALL MEET THE
REQUIREMENTS OF 1 HE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REQUIRED AND CONDITIONS OF
l
OARD
SGUTHkFtWMSTEES
OCCU'P:ANCY OR
USE 1'8S UNLAWFUL
WITHOUT CERTIFICAT'
OF OCCUPANCY
I 1 - -
Comfort 1 6nditioner
. o - - • - e'arrier
1 —112 to 5 Nominal. •
tunn'to •®
Product Data
INDUSTRY LEADING
FEATURES/ BENEFITS
s�"= Efficiency
SCS
E s <� cienc
� �,; ? • 13 SEER/up to 11 EER
(based on tested combinations)
• Microtube Technology�" refrigeration system
• Indoor air quality accessories available
�IIIIIIIIIIIIIIIII «II n Sound
��lll� IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII.p
NIIiIIgIIINl �I � • Sound level as low as 71 dBA
�Illllllil�iln n IIIIIIIIIIIIIIIIIIIIIII�IIIIII� " Comfort
Illlllliillllll�IIIIIIIIiI I • System supports Edged Thermidistat- or standard
11111@�lellp6��il IIIIIIIIINIIIIIIIIIIII thermostat controls
I�11111i1i1IIlIgIIlI18I IIII�I g Reliability
iIIIIII IIIII�IIIII
• Non-ozone depleting Puron®refrigerant
ullllRl�I�III�III • Scroll compressor
• Internal pressure relief valve
�
Comfort
���®�� : Internal thermal overload
Filter drier
uronS E I E S • Balanced refrigeration system for maximum reliability
Durability
Carrier's Air Conditioners with Puron@ refrigerant provide a WeatherArmor- protection package:
collection of features unmatched by any other family of . Solid,durable sheet metal construction
equipment. The 24ABB has been designed utilizing Carrier's
non-ozone depleting Puron refrigerant. • Dense wire coil guard
• Baked-on,complete outer coverage, powder paint
NOTE: Ratings contained in this document are subject to Applications
change at any time. Always refer to the AFRI directory
(www.ahridimetory org) for the most up-to-date ratings ° Long-line-up to 250 feet(76.20 m) total equivalent
information. length, up to 200 feet (60.96 m) condenser above
evaporator,or up to 80 ft.(24.38 m)evaporator above
condenser(See Longline Guide for more information.)
• Low ambient (down to -20°F/-28.9°C)) with
accessory kit
MAR o 7 2022
Elflt3k"jaw tJ1aAj-
MWMCFSQVNf0W
Y
n
MODEL NUMBER NOMENCLATURE
1 2 3 4 5 6 7 8 9 10 1.1 12 13,
N N A •A A/N N N N A/N A/N' AIN, N N
2 4 A B B 3 3 6 A �o N 3 0
Product Product Major SEER Cooking Grille Variations Design
Tier RegionVoltage Series
Series Family Series Capacity Variation
3=208/230—.1 0
24=AC . A=RES AC B=Comfort B=Puron 3=13 SEER 1 no Btuh A=Dense Grille N=North 5 6=46 13 Original
(nominal) 6=460/3 Series
1 =575/3
Pyr®n _ C U. L us
Use of the AHRI Certified
TM Mark indicates a
manufacturer's
"participation in the
program For verification
of certification for individual
products,go to ISO 9001
www.ahridirectolorg, pMl-SAI Global
STANDARD FEATURES
Feature 18 24 30 36 42 48 60
Puron Refrigerant; X X X X X X X
SEER 13 13 13 13 •13 13 13
Scroll Compressor X X X X . X X X
Field Installed Filter Drier X X X •X X X• X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X, X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
Dense Grille X X X X X X X
X'--Standard
2
PHYSICAL DATA
. , ,
UNIT SIZE SERIES 78-34 24-35 30-33' 30-51 36-3536-51' 42-30 48-51,
35 61,11 50,60 -36 61,11 — 60-52,
62,12
Compressor Type Scroll
REFRIGERANT Purons(R-410A)
Control TXV(Puron®Hard Shutoff)
Charge Ib(kg) 3.15 3.15 4.62 4.10 5.42 5.34 5.84 7.37 7.00 8.80 8.00
(1.4) (1.43) (2.10) (1.9) (2.46) (2.4) (2.65) (3.34) (3.2) (4.0) (3,6)
COND FAN Propeller Type,Direct Drive
Air Discharge Vertical .
Air Qty(CFM) 1792 2218 2163 2218 3167 1 2954 3167 3365 3365 3365 3365
Motor HP 1/12 1/10 1/10. 1/10 115 1 -1/4. 1/5 1/4 1/4 1/4 1/4
Motor RPM 1100 1100 1100 1100 110o 1100 1100 1100 1100 800 1100
COND COIL
Face Area(Sq ft) 8.40 8.40 11.49 9.80 12.93 13.13 17.25 19.40 19.40 12.93 15.09
Fins per In. 20 25 25 25 25 25 25 25 25 20 20
Rows 1 1 1 1 1 1 1 1 1 2 2
Circuits 3 3 3 3 5 3 4 5 5 5 6
VALVE CONNECT(In.ID)
Vapor 3/4 3/4 3/4 3/4 718 7/8 7/8 7/8 7/8 7/8 7/8
Liquid 3/8 3/8 3/8 3/8 318 3/8 3/8 318 318 318 3/8
REFRIGERANT TUBES*(In,OD)
Rated Vapor* 3/4 7/8 1-1/8
Max Liquid lint 3/6
*Units are rated with 25 ft(7.6 m)of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
t See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.
OUTDOOR UNIT CONNECTED TO A FACTORY APPROVED INDOOR UNIT
Check piston size shipped with indoor unit to se6"if it,matches required indoor•piston size. If-it does not match,replace indoor piston with
correct piston size in table below:
OUTDOOR UNIT SIZE—SERIES FAN COIL PISTON SIZE BY OUTDOOR MODEL
18-34 FB4CNF* 49
24-35 FB4CNF* 55
30-33 FB4CNF* 61
30-51 FB4CNF* 59
36-35 FB4CNF*
36-51,61,11 FB4CNF* 67
42-30,50,60 FB4CNF* 73
48-36 FB4CNF* 78
48-51,61,11 FB4CNF* 76
* Ratings contained in this document are subject to change at any time.Always refer to the AHRI directory(www.ahridirectory.org)for the most up—to—date
ratings information.
NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. The piston included with the FFMANP*and FPMAN*
fan coils are unique to those products and CANNOT be replaced with the piston shipped with outdoor unit. Refer to the AHRI directory
(www.ahridirectory.org)to check if your Combination can use a piston or requires an accessory TXV.
3
r
REFRIGERANT PIPING LENGTH LIMITATIONS
Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron®Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and
outdoor units.
See Table below for liquid line sizing and maximum lengths
Maximum Total Equivalent Length
Outdoor Unit BELOW Indoor Unit
Liquid AC with Puron Refrigerant
Liquid Line Line Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor
Size Connection Diam. Vertical Separation It(m)
W/TXV 0-5 6-10 11-20 21-30 31-40 41-SO 51-60 61-70 71-80
(0-1.5) (1.8-3.0) (3 4-8.1 (6R-9.1 (9.4-122 (12.5-15.2) 15.5-18.3) (18.6-21.3) 21.6-24A
114 150 150 125 1 100 100 75 -- -- --
18 3/8 5/16 250* 250* 250* 1 250* 250* 250* 250* 225* 150
3/8 250* 250* 250* 1 250* 250* 250* 250* 250* 250*
1/4 75 75 75 50 50 -- -- -- --
24 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
1/4 30 -- -- -- -- -- -- -- --
30 3/8 5/16 175 225* 200 175 125 100 75 -- --
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
36 3/8 5/16 175 150 150 100 100 100 75 -- --
3//8 250* 250* 250* 250* 250* 250* 250* 250* 250'
42 3/8 5/16 125 100 100 75 75 50 -- -- --
3/8 250* 250* 250* 250* 250* 1 250* 250* 250* 150
48 318 318 250* 250* 250* 250* 250* 1 250* 230 160 ——
60 3/8 3/8 1 250* 250* 250* 225* 190 150 --
* Maximum actual length not to exceed 200 ft(61 m)
t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details.
--=outside acceptable range
Maximum Total Equivalent Length
Outdoor Unit ABOVE Indoor Unit
Liquid AC with Puron Refrigerant
Liquid Line Line Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor
Size Connection Diam. Vertical Separation ft(m)
w/TXV 25 26-50 51-75 76-100 101-125 126-150 151-175176-200
(7.6) (7.9-152) (15.5-22.9) (232-30,5) (30.8-38.1) 38.4-45.7) (46.0-53.3) (53.6-61.0)
1/4 175 250* 250* 250* 250* 1 250* 250* 250*
18 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
1/4 100 125 175 200 225* 250* 250* 250*
24 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
1/4 30 -- -- -- -- -- -- —=
30 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
36 3/8 5/16 225* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
42 3/8 5/16 175 200 250* 250* 250* 250* 250* 250*
318 250* 250* 250* 250* 250* 250* 250* 250*
48 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250*
60 318 318 250* 250* 250* 250* 250* 250* 250* 250*
*Maximum actual length not to exceed 200 It(61 m)
t Total equivalent length accounts for losses due to elbows or Fitting.See the Long Line Guideline for details.
--=outside acceptable range
4
REFRIGERANT CHARGE ADJUSTMENTS
Liquid Line Size Puron Charge oz/ft(g/m)
3/8 0.60(17,74)
(Factory charge for lineset=9 oz/266.16 g)
5/16 0.40(11.83)
1/4 0,27(7.98)
Units are factory charged for 15 ft(4.6 m)of 3/8"liquid line. The factory charge for 3/8"lineset 9 oz. When using other length or diameter
liquid lines,charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length)-(factory charge for lineset)]=charge adjustment
Example 1:System has,15 ft of line set using existing 1/4"liquid line. What charge adjustment is required?
Formula: (.27 oz/ft x 15ft)-(9 oz)=(4.95)oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16"liquid line.What is the charge adjustment?
Formula: (.40 oz/ft.x 45ft)-(9 oz.)=9 oz.
Net result is to add 9 oz of refrigerant to the system
NOTE: Conditions must be favorable for charging by subcooling method.Indoor temperature must be 70°F to 80°F(21.1°C to 26.7°C),
and outdoor temperature must be 70°F to 100°F(21.1*C to 37.8°C).If outside these conditions,adjust charge for long line sets by weigh-in
method.
LONG LINE APPLICATIONS
An application is considered Long Line, when the refrigerant leve) in the system requires the use of accessories to maintain acceptable
refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line
depends on the liquid line diameter,actual length of the tubing,and vertical separation between the indoor and outdoor units.
For Air Conditioner systems,the chart below shows when an application is considered Long Line,
AC with Puron®Refrigerant Long Line Description ft(m)Beyond these lengths,a TXV is required
Total Length Outdoor Unit Above or Below Indoor Unit
TXV required beyond 50 ft.(15.2 m) TXV required beyond 20 ft.(6.1 m)
AC with Puron®Refrigerant Long Line Description ft(m)(Beyond these lengths,long line accessories are required)
Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor
1/4+TXV No accessories needed within al- No accessories needed within 175(53.3)
lowed lengths allowed lengths
5/16+TXV 120(36.6) 50(15.2)vertical or 120(36.6)total 120(36.6)
3/8 +TXV 80(24.4) 35(10.7)vertical or 80(24.4)total 80(24.4)
Note: See Residential Piping and Long Line Guideline for details
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for AC systems with Puron refrigerant:
Vapor Line Sizing and Cooling Capacity Losses-Puron®Refrigerant 1-Stage Air Conditioner Applications
Maximum Cooling Capacity Loss(%)
Unit Vapor Line Total Equivalent Line Length ft.(m)
Nominal meters Liquid Line Diameters 1-Sta a AC with Puron
Size(8tuh) (i -Stage
(in.OD) 25-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250
(7.9-15.2) (15.5-24.4) (24.7-305) 30.8-38.1) (38.4-45.7) (46.0-53,3) 53.6-61.0) (61.3-68.6) (68.9-76.2)
1/2 1 2 3 5 6 7 . '8 _ 9' 11
18 3/8 5/8 0 1 1 1„ ' ,2.. ;2.:
3/4 0 ,0 0 0 ';..1 1 1:=„ 1 .. "'1"
5/8 0 1 ,2 - .2 3.. 3
24 3/8 3/4 0 0 1 1 1 1 1 2 2.
7/8 0 1 0 ,0 0,.... .0' . . -1 i _ 1. 1, .
5/8 1 2 3 3 4' . 5 6 7 8
30 3/8 3/4 0 0 "2'-.
7!8 0 0 0 0 1
- .,
5/8 1 2 4,. 5 6 ;`6 i; .9.`. 10 -12.
36 3/8 3/4 0 1 1 2 _ 2 3 3 4 -4,
7/8 0 0 0. 1 1 1 1. 2 2, -
3/4 0 1 :=,2 ..2 3
42 3/8 7/8 0 10 1 `..,.1. 1- ... 2., 2. ....: 3_. _
11/8 0 1 0 0 0 0.- 0 .0 0; 0
3/4 0 1 2 3 4 S, 5, E
48 3/8 7/8 0 0 1' 1 2 •. 2,, ,2 3 3
11/8 0 0 0 =`0 0:
3/4 1 2 4 5 6 7 9f . 10•
60 3/8 7/8 0 1 2',_ 2 3 4 •4 5 8'
11/8 0 0 0 1, 1 S 1 1 1
A licattons In this area,ma be ion gine and ma Have fie�ht restrictions:See the R6Sident/af Pip-.in aed Lon Llni,`Guideline ,
5
ACCESSORIES
size-Voltage,Sales
KIT NUMBER KIT NAME
18-34 24-35 90-33 '30-51 36-35 36-51 38=61 36-11 42-30 42-50 42=60 48-36 48-51 46-61 48-11 60-34 60=52 60-62 60-12
HC38GE461 MOTOR,FAN X
HC40GE466 MOTOR,FAN X X
KAACH1201AAA CRANKCASE HEATER KIT X X X X X X
KAACL41401AAA CRANKCASE HEATER KIT X -'X X.. X X X
KAACH1501AAA CRANKCASE HEATER KIT X
KAACH1801AAA CRANKCASE HEATER KIT X
KMOH1901AM CRANKCASE HEATER KIT X X X
KAACH2O01AAA CRANKCASE HEATER KIT X X
KAAFT0101AAA FREEZE THERMISTOR KIT X X X X X X X X X X- X X X X X X X X X
KAATD0101TDR TIME DELAY KIT X X X X X X X X X X X X X X X - X X X X
KSACY0101AAA CYCLE PROTECTOR KIT X X X X X X X X- X X X X - X X X X X X X
KAAWS0101AAA WINTER START KIT X X X X X X X' X X X X X X X X X X X X
A0
KSAL301410 LOW AMBIENT KIT X ..x X X X X 'X• X X X X X X X X X X X X
KSALA0601AAA MOTORMASTER KIT X X: X X X X X X X X X X
KSALA0701AAA MOTORMASTER KIT X X X X
KAALP0401PUR LOW PRESSURE SWITCH KR X X X X X X - X- X: X X X X X X X. X X X X `
KAALP0501PUR HIGH PRESSURE SWITCH KIT X X- X. X X X X X X X X X X X X- X X X X
KSASF0101AAA SUPPORT FEET KIT X X X X X' X X X X X X, X
KSASF0201AAA SUPPORT FEET KIT X -.X - X. X X X, X
KSASH2301COP SOUND BLANKET KIT X X X _X X X X - X X X '-X X
KSASH2461COP SOUND BLANKET KIT - X X X X
KSASH2501COP SOUND BLANKET KIT X X X
KAALS020I LLS SOLENOID VALVE KIT X "'X X X X X X X X X X X X X X X X X X
KSAHS1501AAA COMPRESSOR STARTASSIST X X X X X X X
KSATX0201PUR TXV KIT X X
KSATX0301PUR TXV KR X_ X X X X X X X X -
KSATX0401 PUR TXV KIT X X X X
KSATX0501PUR TXV KIT X X X X
KSBTX0201PUR TXV KIT X X
KSBTX0301PUR TXV KR " X X X X X X X X X
KSSTX0401PUR TXV KIT X X X X X X X X
X=Accessory ,
AHRI RATINGS
For AHRI ratings certificates,please refer to the AHRI directory www.ahridirectory.ora
Additional ratings and system combinations can be accessed via the Carrier database at:wwini.MyCarrierRAtin sc,s..com
For performance data at specific application&/or design conditions with various indoor,unit combinations,the equipment
performance calculator can be accessed at: http://rpmob.wriahtsoft.com/
ACCESSORY THERMOSTATS ,
PART NUMBER DESCRIPTION
TP—WEM01 Cor-Thermostat
TP—PRH01—A edge'"Programmable Relative Humidity Thermostat
TP—PAC01 edge'Programmable Thermostat
TP—NRH01 edge—Non—Programmable Relative Humidity Thermostat
TP—NAC01 edge—Non-Programmable Thermostat
TC17WHS01 Wi—Fi®Thermostat
TC—PAC01 Programmable Thermostat
TC—NAC01 Non—Programmable Thermostat '
TCSNAC01 Non—Programmable Standard Screen Thermostat
THERMOSTAT ACCESSORIES
PART NUMBER DESCRIPTION THERMOSTATS USED WITH
TP—EXP edge-EXP®Card Programmable edge-thermostats
TSTATCCSEN01-B Outdoor Air Temperature Sensor TP—Pxx,TP—Nxx
TSTATXXCNV10 Thermostat Conversion Kit(4 to 5 wire)—10 pack All Carriers branded thermostats
TX—MBP01 Medium Decorative Backplate TC—Nxx
TX—LBP01 Large Decorative Baokplate TP=Pxx,TP—Nxx,TC—Pxx
ACCESSORY USAGE GUIDELINE
REQUIRED FOR REQUIRED FOR
ACCESSORY LOW—AMBIENT COOLING REQUIRED FOR LONG LINE SEA COAST
APPLICATIONS APPLICATIONS* APPLICATIONS
(Below 55°F/12.8°C) (Within 2 miles/3.22 km)
Ball Bearing Fan Motor Yest No No
Compressor Start Assist Capacitor and Relay Yes Yes No
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Hard Shut—Off TXV Yes Yes Yes
Liquid Line Solenoid Valve No No No
Motor Master9 Control or Yes No No
Low—ambient Pressure Switch
Support Feet Recommended No Recommended
Winter Start Control Yes# No .No
* For tubing set lengths between 80 and 200 ft.(24.38 and 60.98 m)horizontal or 35 ft.(10.7 m)vertical differential(total equivalent length),refer to the
Residential Split—System Longline Application Guideline.
t Required for Low—Ambient Controller(full modulation feature)MotorMastero Control.Standard on all models except 575V 3—phase units.
# Required If Low Pressure Switch is factory or field installed.
Accessory Description and Usage (Listed Alphabetically)
1.Ball-Bearing Fan Motor 3.Crankcase Heater
A fan motor with ball beatings which permits speed reduction An electric resistance heater which mounts to the base of the
while maintaining bearing lubrication. compressor to keep the lubricant warm during off,cycles.
Usage Guideline: Improves compressor lubrication on restart and minimizes the
Required on all units when MotorMastero is used. chance of liquid slugging.
2.Compressor Start Assist-Capacitor and Relay Usage Guideline:
Start capacitor and relay gives a "hard" boost to compressor Required in low ambient cooling applications.
motor at each start up. Required in long line applications.
Usage Guideline: Suggested in all commercial applications.
Required for reciprocating compressors in the 4. Cycle Protector
following applications: The cycle protector is designed to prevent compressor short
Long line cycling. This control provides an approximate 5-minute delay
Low ambient cooling after power to the compressor has been interrupted for any
Hard shut off expansion valve on indoor coil reason,including power outage,protector control trip,thermostat
Liquid line solenoid on indoor coil jiggling,or normal cycling.
Required for single-phase scroll compressors in the
5.Evaporator Freeze Thermostat
following applications: An SPST temperature-actuated switch that stops unit operation
Long line when evaporator reaches freeze-up conditions.
Low ambient cooling Usage Guideline:
Suggested for all compressors in areas with a history of Required when low ambient kit has been added.
low voltage problems.
7
Accessory Description and Usage (Listed Alphabetically) (Continued)
6.Low-Ambient Pressure Switch Kit 10.Support Feet
A long life pressure switch which is mounted to outdoor unit . Four or five stick-on plastic feet that raise the unit 4 in.(101.6
service valve. It is designed to cycle the outdoor fan motor in mm) above the mounting pad.This allows sand,dirt, d other
order to maintain head pressure within normal operating limits debris to be flushed from the unit base,minimizing corrosion.
ansion.
(approximately 100 psig to 225 psig).The control will maintain Usage Guideline:
working head pressure at low-ambient temperatures down to 0°F Suggested in the following applications:
(-18°C)when properly installed.
Coastal installations.
Usage Guideline:
Windy areas or where debris is normally circulating.
A Low-Ambient Pressure Switch or MotorMaster®
Low-Ambient Controller must be used when cooling operation is Rooftop installations.
used at outdoor temperatures below 55°F(12.8°C). For improved sound ratings.
7.MotorMaster®Low-Ambient Controller 11,Thermostatic Expansion Valve(TXV)
A fan-speed control device activated by a temperature sensor, A modulating flow-control valve which meters refrigerant liquid
designed to control condenser fan motor speed in response to the flow rate into the evaporator in response to the superheat of the
saturated, condensing temperature during operation in cooling refrigerant gas leaving the evaporator.
mode only.For outdoor temperatures down to-20°F(-28.9°C), Kit includes valve, adapter tubes, and external equalizer tube.
it maintains condensing temperature at 100'F t10°F(37.8°C: 'Hard shut off types are available.
5.5-C). NOTE: When using a hard shut off TXV with single phase
Usage Guideline: reciprocating compressors, a Compressor Start Assist Capacitor
A MotorMaster® Low Ambient Controller or and Relay is required.•
Low-Ambient Pressure Switch must be used when Usage Guideline:
cooling operation is used at outdoor temperatures Required to achieve AHRI ratings in certain equipment
below 55°F(12.8°C). combinations.Refer to combination ratings.
Suggested for all commercial applications. Hard shut off TXV or LLS required in air conditioner
8.Outdoor Air Temperature Sensor ' long line applications.
Designed for use with Carrier Thermostats listed in this Required for use on all zoning systems.
publication. This device enables the thermostat to display the 12.Time-Delay Relay
outdoor temperature.This device also An SPST delay relay which briefly continues operation of indoor
is required to enable special thermostat features such as auxiliary blower motor to provide additional cooling after'the compressor
heat lock out. cycles off.
Usage Guideline: NOTE:Most indoor unit controls include this feature.For those
Suggested for all Carrier thermostats listed in this that do not,use the guideline below.
publication. Usage Guideline:
9.Sound Hood For improved efficiency ratings for certain
Wraparound sound reducing cover for the compressor. Reduces combinations of indoor and outdoor units.Refer to
the sound level of the compressor. AHRI Unitary Directory.
Usage Guideline: 13. Winter Start Control
Suggested when unit is installed closer than 15 ft(4.57 m)to This control is designed to alleviate nuisance.opening of the
quiet areas,bedrooms,etc. ` low-pressure switch by bypassing it for the first 3 minutes of
Suggested when unit is installed between two houses less operation.
than 10 ft(3.05 m)apart.
8
ELECTRICAL DATA
UNIT
OLTAIZ E, V/RH OPER VOLTS* COMPR FAN MCA MAXFUSE**or
SERIES MAX MIN LRA RLA FLA CKTBRKAMPS
18-34 47.5 9.0 0.50 11.8 20
24-35 62.9 10.9 0.70 14.3 25
30-33 67.8 12.8 0.60 16.6 25
36-35 208/230/1 253 197 79.0 13.6 1.10 18.1 30
42-30 112.0 17.9 1.10 23.5 40
48-36 93.0 18.3 1.40 24.3 40
60-34 125.0 22.1 1.40 29.0 50
30-51 58.0 8.3 0.77 11.2 20
36-51 71.0 10.5 1.40 14.5 20
42-50 208/230-3 253 187 88.0 1 .5 1.10 18.0 30
48-51 83.1 13.1 1.40 17.8 30
60-52 110.0 16.0 1.40 21.4 30
36-61 3B.0 5.6 0.70 7.7 15
42-60 44.0 6.0 0.60 8.1 15
48-61 460-3 506 414 41.0 6.1 0.70 8.3 15
60-62 52.0 7.8 0.70 10.5 15
36-11 36.5 3.8 0.50 5.3 15
48-11 575-3 532 518 33.0 4.4 0.50 6.0 15
60-12 38.9 5.7 0.50 7.6 15
*Permissible limits of the voltage range at which the unit will operate satisfactorily.
**Time-Delay fuse.
FLA -Full Load Amps
LRA -Locked Rotor Amps
MCA-Minimum Circuit Amps
RLA -Rated Load Amps
NOTE: Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1
A-WEIGHTED SOUND POWER LEVEL
STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA,without tone adjustment)
24ABB3 UNIT SIZE RATING
dBA 125 250 500 1000 2000 4000 8000
18-34 71 64.0 62.0 63.0 68.0 64.0 62.0 57.0
24-35 74 50.9 60.6 66.4 71.0 65.5 61.1 59.2
30-33 72 54.8 59.3 65.1 68.2 66.4 61.6 57.3
30-51 74 55.0 63.5 68.5 68.5 65.5 61.0 54.0
36-35 75 50.5 61.0 64.5 67.0 62.5 60.0 52.5
36-51,61,11 75 59.5 63.0 68.5 70.0 65.5 61.5 53.5
42-30,50,60 78 57.5 65.071.0 73.0 70.5 67.5 62.5
48-36 76 55.5 62.9 69.6 71.2 69.5 66.3 59.1
48-51,61,11 80 58.5 67.5 73.5 75.0 70.5 67.5 64.5
60-34 79 57.5 67.0 72.0 75.0 72.5 68.0 61.0
60-52,62,12 79 59.5 69.5 72.5 73.5 71.0 68.0 63.5
NOTE: Tested in accordance with AHRI Standard 270-2008(not listed in AHRI).
A-WEIGHTED SOUND POWER LEVEL WITH SOUND SHIELD
STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA,without tone adjustment)
UNIT SIZE RATING
dBA 125 250 500 1000 2000 4000 8000
18-34 70 66.0 64.0 64.0 67.0 63.0 60.0 54.0
24-35 74 51.1 61.3 66.6 71.2 65.0 60.0 55.6
30-33 72 51.9 59.3 64.8 67.3 65.2 61.1 54.8
30-51 73 55.5 64.0 68.0 67.0 64.0 60.0 52.5
36-35 75 51.0 62.0 64.5 65.5 62.0 59.5 51.5
36-51,61,11 74 59.5 63.0 68.0 69.5 65.0 60.5 50.5
42-30,50,60 77 57.5 65.0 70.5 72.0 70.0 67.0 62.0
48-36 75 55.8 62.6 69.7 70.6 68.7 65.4 58.6
48-51,61,11 79 60.5 67.5 73.5 74.5 71.0 68.0 63.5
60-34 79 57.5 68.0 72.5 74.5 72.5 68.0 60.5
60-52,62,12 78 60.5 69.5 72.5 73.0 71.0 67.5 61.5
NOTE: Tested in accordance with AHRI Standard 270-2008(not listed in AHRI),
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)
UNIT SIZE-VOLTAGE&SERIES REQUIRED SUBCOOLING°F(°C)
18-34 14(7.8)
24-35 10(5.6)
30-33,51 10(5.6)
36=35 11(6.1)
36-51,61,11 14(7.8)
42-30,50,60 10(5.6)
48-36 13(7.2)
48-51,61,11 15(8.3)
60-34 15(8.3)
60-52,62,12 10(5.6)
9
DIMENSIONS - ENGLISH
SHIPPING
OPERATING WEIGHT
SHIPPMG
UNIT SERIES ��C� '4 B C 0 E F G H I U R WEIGHT WEIGHT �/, HEIGHT
IDTH
CHARACTERISTICS
INCH MIA INCH IRA INCH AIM INCH NPA INCH NRA INCH NPA INCH KM INCH FON INCH FPA INCH MAY INCH NMA Lbs Kgs Lbs Kgs INCH AAI INCH NM
24ABB318A 4 Y N N N 23 118 587.3 25 5110 642.9 314 19.1 4 7/16 11&0 18 1116 459.0 713116 197.9 5116 7.9 3 76.2 16 112 419.1 15 381.0 12 304.8 107 48.5 130 59.0 25 1/4 641.5 29 34 755.8
24ABB324A 5 Y N N N 23 118 587.3 25 5118 642.9 314 19.1 4 7/16 113.0 18 1118 459.0 713116 197.9 5116 7.9 3, 76.2 12 1/2 317.5 11 279.4 12 304.8 107 48.5 127 57.6 25 1/d 641.5 29 314 755.8
24ABB330A 3 Y N N N 25 3/4 664.0 281V18 728.7 314 19.1 4 7110 113.0 21 1/4 539.9 9 1/8 231.3 5116 7.9 3 762 14 12 368.3 16 112 393.7 12 12 317.5 126 57.2 149 67.6 27 718 708.2 33 3116 843.1
24ABB330A 1 N Y N N 23 118 1 587.3 2$11116 729.3 3/4 161 4 7/16 1130 18 1116 1 469.0 713/16 187.9 5116 7.9 3 762 16 12 419.1 15 381.0 14 355.6 111 50.3. 136 61.7 25 114 641.5 33 3116 843.1
74A86336A 5 Y N N N 31 3116 1 7925 25 5118 642.4 7/8 22.2 6 9116 W&I 24 11116 626.3 9 1/0 231.3 5116 7.9 3 762 15 9116 395.3 16 12 419.1 10 114 260.4 134 60.8 1.51 68.5 33 5116 846.6 29 314 7568
24ABB336A 1 N Y Y Y 25 314 654.0 32 1116 815.1 TIS 222 4 7/16 113.0 21 114 639.9 9 118 231.3 6116 7.9 3 762 14 114 382.0 10 12 266.7 18 406.4 141 64.0 170 1 77.1 27 718 708.2 36 Us 929.5
24ABB342A 0 Y Y Y N 31 3116 792.5 32 VIE 615.1 718 22.2 6 9116 168./ 2411116 626.3 9 118 231.3 S16 7.9 3 76.2 15 314 400.1 16 1/4 412.8 13314 349.3 190 88.2 210 969 33 5/18 848.6 36 516 929.5
24ABB346A 6 Y N N N 31 3116 7925 35 12 901.4 718 22.2 6 9116 166.1 2411116 626.3 9 116 231.3 5116 7.9 3 762 15 314 400.1 16 WEI 415.9 15 518 396.9 175 79.4 205 93.0 33 5116 846.6 40 1015.8
24ABB34BA 1 N Y Y Y 31 3116 792.5 35 12 901.4 718 222 6 8116 166.1 2411/16 626.3 8 1/8 231.3 5116 7.9 3 762 16 318 4159 15 WEI 3905 15 114 387.4 188 84.4 224 101.6 33 5118 846.6 40 1015.8
24ABB360A 4 Y N N N 31 3/16 7925 2811/16 728.7 7/8 222 6 9116 166.1 24 11118 628.3 8 118 231.3 5116 7.9 3 76.2 18 408.4 15 1/2 393.7 12 314 323.9 188 90.3 232 105.2 33 5/10 846.8 33 3116 843.1
24AB6360A 2 N Y Y Y 31 3118 7925 2811116 728.7 1/8 22.2 8 9118 FIGS.1 24 11/18 5263 9 118 231.3 5116 7.9 3 -78.2 16 406.4 15 112 393.7 12 314 323.9 198 898 230 104.3 33 5116 846.8 33 3118 843.1
Y=Y
YYddkdl N=NC)O
A so.
AIR DISCHARGE
AIR IN AIA
F DISCHARGE
1.
H
O
FIELD POSER 501111 CONN• AIA IN
B PI(0118°022.2)NOL'SI iH AIR IN--
1./8°(¢28.6)KNOCKOUT
FIELD CONTROL SUPPLY CONN.
�T/8*1022.21
HOLE � E
\\ -
1C9.5) X
_LIQUIDD LINELINC CONN.
3 3/4° 3 f/2'
' (96.01 (88.91 I� H �
¢CYAPDR LINE CORN.L/ 1� Y SO•� 113116°
r-X so.-
0
o. (as.n vz G
(12.7) } 3/8'19.5)ifEDOSN KNOCKOUTS
.. -Y- IL (21 PLACES
UNIT SI2E MouNsm0' P==FOOF10P NouNlv+a 213116° Ali IN
PIIGIION DMEN-S PAp APPL1Gl10.Y�ME-3 171.0) "
18,24,30(30) 23 118 1 587.3 17 718 1 454.6
30 10 36 3fl ZS 3f4 854.0 20 7/16 516.5
36 10 42 48 60 31 3/16 792.5 22 15/16 583.2 NOTE ALL DIMENSIONS IN INCH(MM) U.S.EXPORT CLASSIFICATION:EAR99
36 889.D 28 3f4 679.7 505418-4REV.0
CLEARANCES
Clearances(various examples)
� � ' Wall �� ��� � s, .� � � °' 4Wa�i � •m,.,
6!f
24"
(152.4 mm). Service
24" 12" 12 : 6"" �f
(609.6) (304.8) (304.8) (152.4)
Service
12" 12"
-r.. _
.- �
(304 8)
04.g
24" 24". 24"
(609.6) (609.6) (609.6)
Service Service - Service
(457.2) (457.2) (457.2)
Note Numbers in (3=mm
IMPORTANT-.,When installing multiple.units din an alcove,roof well,or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air.
DETAILED COOLING CAPACITIES#
EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C)
75(23.9) 85(29.4) 95(35) 1 105(40.6) 115(46.1)
CFM EWS Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- C Pacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Tbtel Sys
°F(°C) Tota! Sens# tem KW*" Total Sean# tem KW** Total Sens* tam KW* Total Sens# tem KW*" Total Sens; tem KW*"
24.AIE3S371:8A.BN34 Outdoor Section With CNPV*2414AU1 indoor Section
72(22.2) 21.21 11.311 1.27 20.31 11.05 1.42 19.41 10.71 1.59 18.37 10.33 1.78 17.33 996 2.07-
67(19.4)
,0267(19.4) 19.33 14.06 1.28 18.52 13.73 1.43 17.62 13.36 1.60 16.64 12.96 1.79 15.65 12.56 2.02
$25 63(17.2)}1 18..04 16.20 1.29 17.23 15.83 1.44 16.39 15.44 1.60 15.49 15.02 1.79 14.60 14.56 2.02
62(16.7) 17.76 16.72 1.29 16.97 16.34 1.44 16.16 15.93 1.60 15.36 15.36 1.79 14.58 14.58 2.02
57(13.9) 17.47 17.47 1.30 16.77 16,77 1.44 16.08 16.08 1.60 15.34 15.34 1.79 14.56 14.66 2.02
72(22.2) 21.47 11.95 1.30 20.62 11.65 1.45 19.68 11.30 1.62 18.64 10.93 1.81 17.55 10.55 2,05
67(19.4) 19.71 15.05 1.31 18.81 14.68 1.46 17.90 14.32 1.63 16.89 13.92 1.62 15.88 13.52 2.05
Goo 63(17.2)tt 16.40 17.43 1.32 17.61 17.15 1.46 16.77 16.64 1.63 15.96 15.96 1.82 15.14 15.14 2.05
62(iB.7) 18.19 18.01 1.32 17.54 17.28 1.46 16,74 16.74 1.63 15.96 15.96 1.82 15.14 15.14 2.05
57(13.9) 18.12 19.12 1.32 17.44 17.44 1.47 16.72 16.72 1.63 15.93 15.93 1.82 15.12 15.12 2.05
72(22.2) 21.70 12.53 1.33 20.81 12.21 1.48 19.86 11.87 1.65 18.78 11.49 1.84 17.62 11.09 2.06
67(19.4) 19.88 15.95 1.34 19.03 15.61 1.49 18.11 15.24 1.66 17.08 14.83 1.85 16.07 14,43 2.08
675 63(17.2)tt 18.79 18.56 1.35 18.02 18.02 1.49 17.27 17.27 1.66 16.44 16.44 1.85 15.60 15.60 2.08
62(16.7) 18.71 f8.71 1.34 18.02 18.02 1.49 17.26 17.26 1.66 16.44 16.44 1,85 15.59 15.59 2.08
57(13.9) 18.70 18.7Q 1.34 18.00 18.00 1.48 1724 17.24 1.66 16.41 16.41 1.85 15.57 15.57 2.08
EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C)
75(23.9) 85(29.4) F 95(3S) 105(40.6) 115(46.1)
CFM EWB CapacityMBtuh Total Sys_ Cepaclty MBluh Total Sys- Capacity MBtuh Total Sys Capac MBtuh Total Sys- Capecity MBtuh Total Sys-
°F(°C) Total Sena tem KW* Total Sens# tam KW** Total Sens1 tem KW** Total Sena# tem KW** Total Sens# tom KW**
Outdbor Section With CNPV*2414AL�indoor Section
72(22.2) 27.00 13.49 1.54 26.00 13.12 1,78 24.88 12.71 2.05 23.60 12.25 2.37 22.20 11,77 2.74
67(19.4) 24.70 16.72 1.54 23.76 16.33 1.78 22.68 15.90 2.05 21.51 15.44 2.37 2029 14.95 2.74
F 700 63(17.2)tt 23.00 16.10 1.55 22.07 15.69 1.78 21.07 15.26 2.06 19.97 14.80 2.37 18.77 14,30 2.75
N 62(16.7) 22.70 19.89 1.55 21.81 19.46 1.78 20.86 18.99 2.06 19.95 19.95 2.37 18.98 18.98 2,75
57(13.9) 22.29 22.29 1.55 21.58 21.58 1.78 20.79 20.79 2.06 19.92 19.92 2.37 18.96 18.96 2.75
72(22-2) 27.39 14.17 1.57 26.35 13.79 1.81 25.20 13.38 2.09 23.87 12.92 2.41 22.42 12.43 2.78
67(19.4) 25.08 17.82 1.58 24.11 17.43 1.82 23.00 17.00 2.09 21,79 16.53 2.41 20.47 16.03 2.78
Sao 63(17.2)tt 23.39 17.14 1.58 22.43 16.72 1.02 21.39 16,28 2.09 20.26 15.81 2.41 19.02 15.30 2.79
62(16.7) 23.24 21.32 1.58 22.43 22.43 1.B2 21.59 21.59 2.09 20.66 20.66 2.41 19.62 19.62 2.79
57(13,9) 23.16 23.16 1.58 22.40 22.40 1.82 21.56 21.56 2.09 20.63 20.63 2.41 19.60 19.60 2.79
72(22.2) 27.66 14.81 1.61 26.59 14.43 1.85 25.41 14.02 2.13 24.05 13.56 2,45 22.57 13.06 2.82
67(19.4) 25.36 16.88 1.61 24.37 18.49 1,85 23.24 18.05 2.13 22.00 17.57 2.45 20.65 17.05 2.82
900 63(17.2)tt 23.67 18.11 1.62 22.70 17.70 1.85 21.63 17.25 2.13 20.47 16.77 • 2.45 19.21 16.24 2.83
62(16.7) 23.89 23.89 1.62 23.10 2310 1.85 22,21 22.21 2.13 21.22 21.22 2.45 20.13 20.13 2.83
57(13.9) 23.86 23.86 1.62 23.07 23.07 1.85 22.18 22.18 1 2.13 21.20 1 21.20 2.45 20.11 20.11 2.83
See notes on page 15
DETAILED COOLING CAPACITIES# CONTINUED
EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F(°C)
75(23.9) 65(29.4) 195(36) 105(40.6) 115(46.1)
CFM EWB Capacity MBtuh Total Sya- Capacity MBtuh Total Sys Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys-
°F CC) Total So
tem KWO° Total Sens# tem KW** Total Sens# tem KW** Total Sena# tem KW** TotalI Sens# tem KW**
2,tABB330ABN33
72(22.2) 3322 16.91 2.06 31.69 16.39 2.26 Outdoor 30.08 15.8412,401•67(19.4) 3026 21.08 2.05 28.91 20.56 2.25 27.54 20.0426.13 19.52 2.76 24.98 19.08 3.10
875 63(17,2)1} 28.16 20.25 2.04 27.05 19.80 2.25 25.78 19.2824AB 18.76 2.76 22.86 18.13 3.08
62(16.7) 28.07 25.27 2.05 26.80 26.56 2.25 25.71 25.7124.60 24.60 2.76 23.29 23.29 3.08
57(13.9) 27.67 27.67 2.04 26.71 26.71 2.25 25.67 25.6724.55 24.55 2.76 23.26 23.26 3.08
72(22.2) 33.61 17.69 2.10 32.00 17.08 2.30 30.30 16.5128.71 15.99 2.81 27.49 15.59 3.14
67(19.4) 30.64 22.21 2.09 29.20 21.67 2.29 27.80 21.15 2.53 26.35 20.61 2.80 25.09 20.14 3.13
970 63(17.2)11 28.55 21.32 2.08 27,34 20.83 2.29 26.03. 20.31 2.52 24.67 19.76 2.79 23.13 19.14 3.11
62(16.7) 28.67 28.67 2.09 27.47 27.47 2.29 26.36 26:36 2.52 25.20 25.20 2.80 24.14 24.14 3.14
57(13.9) 28.57 28.57 2.09 27.43 27.43 229 26.33 26.33 2.52 25.14 25.14 2.79 24.21 24.21 3.13
72(22.2) 34.10 18.74 2.16 32.36 18.17 2.36 30.60 17.59 2.60 28.93 17.05 2.87 27.70 16.66 3.20
67(19.4) 31.10 23.99 2.15 29.57 23.42 2.36 28.11 22.88 2.59 26.63 22.32 2.86 25.46 21.89 3.21
1125 63(17.2)tt 2925 23.06 2.15 27.68 22.44 2.35 26.34 21.90 2.59 24.91 21.33 2.86 23.65 20.80 3.19
62(16.7) 1 29.57 29.57 2.15 26.41 28.41 2.35 27.20 27.20 2.59 1 25.99 25.99 2.86 1 25.03 25.03 1 3.20
57(13.9) 1 29.57 29.57 2.15 28.38 28.36 2.35 27.20 27.20 2.59 1 25.95 25.95 2.66 24.99 24.99 3.20
EVAPORATOR AIR CONDENSER ENTERING AIRTEMPERATURES °F(°C)
75(23.9) 65(29.4) 95(35) 105(40.6) 115(46.1)
CFM EWB Capacity MBtuh Total Sys- Capacity MBtuh Total Sys Capacity MBtuh 7ota1 Sys- Capacity MBtuh Total Sys Capachy MBtuh Total Sys-
°F(°C) Total Sens# tem KW** Total San tem KW..
Total Sens# tem KW* Total Sens# tem KW** Total Sena# tem KW**
•
72(22.2) 41.02 21.66 2.54 39.40 21.07 2.83• Section 37.67- 20.45 3:14 35.71 19.75 3.48 33.44 18.95 3,91
r 67(19.4) 37.34 26.81 2.53 35.82 26.20 2.81 34.20 25.55 3.11- 32.39 24.83 3.45 30.24 23.98 3.87
w 1050 63(17.2)tt 34.68 25.78 2.53 33.23 25.15 2.81 31.71 24.49 3.10 29.97 23.75 3.44 27.94 22.89 3.85
62(16.7) 34.09 31.81 2.53 32.69 31.14 2.81 31.25 31.03 3.10 29.79 29.79 3.44 28.17 28.17 3.85
57(13.9) 33.44 33.44 2.53 32.31 32.31 2.81 31.10 31.10 3.10 29.74 29.74 3.43 28.12 28.12 3.85
72(22.2) 41.67 22.87 2.60 40.00 22.28 2.90 38.19 21.64 3.21 36.16 20.93 3.56 33.84 20.12 3.98
67(19.4) 37.97 28.72 2.59 36.42 28.10 2.88 34.74 27.44 3.18 32.86 26.71 3.52 30.66 25.85 3.93
1200 63(17.2)tt 35.32 27.56 2.59 33.82 1 26.92 2.87 32.24 26.25 3.17 30.45 25.49 3.50 28.36 24.62 3.92
62(16.7) 35.04 34.70 2.59 33.72 33.72 2.87 32.44 32.44 3.16 30.99 30.99 3.50 29.26 29.26 3.92
57(13.9) 34.87 34.87 2.59 33.87 33.67 2.87 32.39 32.39 3.16 30.95 30.95 3.50 29.22 29.22 3.92
72(22.2) 42.14 24.02 2.67 40.41 23.42 2.97 38.56 22.78 3.28 36.48 22.06 3.63 34.10 21.25 4.05
67(19.4) 39.45 30.58 2.65 36.85 29.95 2.94 35.14 29.28 3.24 3322 28.53 3.56 30.99 27.65 4.00
1350 63(17.2)tt 35.80 29.28 2.65 34.26 28.63 2.93 32.63 27.95 3.23 30.83 27.19 3.57 20.68 26.27 3.98
62(16.7) 36.12 36.12 2.65 34.86 34,86 2.93 33.50 33.50 3.23 1 31.98 31.98 3.57 30,16 30.16 3.99
57(13.9) 36.07 36.07 2.65 34.81 34.81 2.93 33.45 33.45 3.23 31.94 31.94 3.57 30.12 30.12 3.99
DETAILED COOLING CAPACITIES# CONTINUED
EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C)
75(23.9) 85(29.4) 95(35) 105(40.6) 115(48.1)
CFM EM Capacity MBtuh Totei Sys Capacity MBtuh Total Sys Cepadty MBtuh Tbtel Sys Capacity MBtuh Total Sys. Capacity MBtuh 7iNel Sys.
°F(°C) Total Sena# tem KW+' Totel Sens# tem KW" Totet Sens# tem KW** Total Sens# tem KW** Total Sens# tam KW"
O Outdoor Section With 42 Indoor Section
72(22.2) 48.49 25.49 3.39 46.39 24.69 3.73 44.18 23.65 4.11 41.63 22.97 4.52 39.28 22.03 4.98
67(19.4) 44.47 31.36 3.33 42.52 30.54 3.67 40.46 29.67 4.05 38.28 28.77 4.47 35.93 27.82 4.92
1225 63(17.2)tt 41.53 30.43 329 39.69 29.59 3.63 37.74 28.72 4.01 35.68 27.80 4.43 33.47 26.84 4.88
62(16.7) 40.83 37.19 3.28 39.07 36.35 3.63 37.22 35.45 4.00 35.29 34.48 4.42 33.32 33.32 4.88
57(13.9) 39.73 39.73 3.27 38.29 38.29 3.62 36.76 36.76 4.00 35.12 35.12 4.42 33.34 33.34 4,88
72(22.2) 49.21 26:62 3.47 47.02 25.80 3.81 44.73 24.95 4.19 42.30 24.06 4.61 39.67 23.11 5.06
67(19.4) 45.16 33.20 3.42 43.14 32.37 3.76 41.00 31.49 4.13 38.75 30.59 4.55 36.34 29.63 5.01
1400 63(17.2)tt 42.22 32.16 3.38 40.31 31.31 3.72 38.28 30.42 4.09 36.17 29.51 4.51 33.89 28.53 4.97
62(16.7) 41.69 39.75 3.37 39.91 38.85 3.71 38.02 38.02 4.09 36.34 36.34 4.51 34.45 34.45 4.98
57(13.9) 41.25 41.25 3.37 39.72 39.72 3.71 38.08 38.08 4.09 36.34 36.34 4.51 34.45 34.45 4.98
72(22.2) 49.75 27.70 3.56 47.50 26.88 3.90 45.14 26.02 4.27 42.64 25.12 4.69 39.94 24.16 5.14
67(19.4) 45.69 34.99 3.50 43.61 34.15 3.84 41.42 33.28 4.22 39.12 32.36 4.63 36.65 31.38 5.09
1575 63(17.2)tt 42.75 33.85 3.46 40.79 33.00 3.80 38.72 32.11 4.17 36.55 31.18 14.59 34.23 30.18 5.05
62(16.7) 42.52 42.08 3.46 40.87 40.87 3.80 39.14 39.14 4.18 37.31 37.31 4.61 36.32 35.32 5.07
57(13,9) 42.49 42.49 3.46 40.87 40.87 3.80 39.15 39.15 4.18 37.32 37.32 4.61 35.32 35.32 5.07
See rotes on page 15
EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C)
75(23.9) 85(29A) 95(35) 1 105(40.6) 115(46.1)
CFM EWB Capacity MBtuh Total Sys- Capaefty MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys- Capacity MBtuh Total Sys.
+ tem KW** ibtai Sens# tem KW** Total Sens# tem KW Totel Senst tam KW**
IF CC) Total Sens# tam KW Tote) Sens#
Outdoor
µ 72(222) 53.87 27.47 3.18 51.45" 2627 3.59 48.92 25.05 4.07 46.25 23.62 4.61 43.41 22.56 5.21
A 67(19.4) 49,06 33.61 3.16 46.83 32.31 3.56 44.50 31.00 4.05 42.04 29.66 4.59 39.41 28.30 5.19
1275 63(17.2)tt 45.60 32.39 3.14 43.53 31.11 3.55 41.33 29.80 4.03 39.02 28.47 4.57 36.55 27.11 5.18
62(16.7) 44.79 39.62 3.14 42.76 38.21 3.55 40,64 36.76 4.02 38.42 35.26 4.57 36.16 36.16 5.17
57(13.9) 43.29 43.29 3.13 41.65 41.65 3.54 39.91 39.91 4.02 38.08 38.08 4.56 36.11 36.11 5.17
72(22.2) 54.71 28.64 3.23 52.22 27.41 3.65 49.58 26.17 4.13 46.83 24.91 4.67 43.91 23.63 5.28
67(19.4) 49.84 35.47 3.22 47.54 34.13 3.63 45.12 32.78 4.11 42.58 31.40 4.65 39.90 29.99 5.26
1425 63(17.2)(•t 46.35 34.12 3.21 4420 32.79 3.61 41.94 31.45 4.09 39.55 30.08 4.64 37.02 28.68 5.24
62(16.7) 45.62 42.07 3.20 43.55 40.56 3.61 41.43 41.12 4.09 39.37 39.37 4.63 37.29 37.29 5.24
57(13.9) 44.80 44.80 3.20 43.09 43.09 3.61 41.25 41.25 4.09 39.31 39.31 4.63 37.24 37.24 5.24
72(22.2) 55.37 29.76 3.29 52.79 28.51 3.71 50.09 27.24 4.19 47.26 25.96 4.74 44.27 24.65 5.34
67(19.4) 50.46 37.27 3,28 48.09 35.89 3.69 45.61 34.49 4.17 43.01 33.08 4.71 40.26 31.63 5.32
1575 63(17.2)tt 46.96 35.79 3.27 44.74 34.42 3.67 42.42 33.04 4.15 39.97 31.63 4.70 37.38 30,19 5.30
62(16.7) 46.40 44.30 3.26 44.37 44.37 3.67 42.45 42.45 4.15 40.42 40.42 4.70 38.25 38.25 5.31
57(13.9) 46.10 46.10 3.26 44.30 44.30 3.67 42.39 42.39 4.15 40.36 40.36 4.70 38.20 38.20 5.31
See notes on page 15
DETAILED COOLING CAPACITIES# CONTINUED
EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F('C)
75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7)
EWB Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh Total Capacity MBtuh 'Total Capacity Mutt Total
CFM System System System Syat*m , Total Sens# KWt"n Total SO' SC1Nem
'F(�C) Total Sens# KW Total Sens# KW Total Sens# KW Total Sans# KW
0• Outdoor , ••
72(22.2) 68.71 34.82 4.37 65.76 33.74 4.81 62.59 32.60 5.30 59.21 31.39 5.84 55.54 30.09 6.42 51.41 28,66 7.Q5
67(19.4) 63,16 43.00 4,29 60.43 41.90 4.74 57.50• 40.73 5.23 54,39 39.50 5.77 . 51.03 3820 6.36 47.32 36.77 6.99
1750 63(17.2)tt 59.15 41.60 4.24 56.59 40.69 4.68 53.84' 39.50 5.18 50.92 38,26 5.72 47.79 36.96 6.31 44.36 35.54 6.95
62(16.7) 58.14 51.13 4.23 55.65 49.99 4.67 53.01 48.77 5.16 50.27 47.45 5.71 47.55 47.55 6.31 44.70 44.70 6.96
57(13.9) 56.63 56,63 4.21 54.60 54.60 4.66 52.42 52.42 5.16 50.09 50.09 5.71 47.55 47.55 6.31 44.71 44.71 6.96
72(22.2) 69.71 36.45 4.48 66.67 35.37 4.92 63.38 34.20 5.41 59.88 32.98 5.95 56.07 31.67 6.53 51.80 30.21 7.15
67(19.4) 64.15 45.67 4.40 61.31 44.55 4.85 58.27 43.36 5.34 55.05 42.13 5.67 51.58 1 40.80 6.46 47.74 39.34.-. 7.10
2000 63(17.2)tt 60.14 44.30 4.35 57.47 43.18 4.79 54.61 41.98 5.28 51.60 40.73 5.82 48.36 39.39 6.42 44.82 37.93 7.06
62(16.7) 59.33 54.75 4.34 56.80 53.54 4.78 54.23 " ' '54.23 5.28 51.77 51.77 5.83 49.05 49.05 6.42 4529 45.99` 7.07
57(13.9) 58.75 58.75 4.33 56.59 56.59 4.78 54.26 - 54.26 5.26 51-.77 51.77 5,83'- 49.05 49.05 6.42 46A0 46.00' 7.07
72(22.2) 70.44 37.99 4.59 67.31 36.90 5.03 63.93- 35.73 5.52 60.33 34.49 6.05' 56.41 33.16 6.63 52.03 31.69 7.25
67(19.4) 64.85 48.20 4.51 61.94 47.09 4.95 56.82',. 45.89 5.44 55.52 44.63 5.98_ 51.96 43.27 6.56 48.04 41.75 7.20
2250 63(17.2)tt 60.84 46.68 4.45 58.11 45.56 4.80 55.17'-°. 44.34 5.39 52.08 43.07 5.93 48.77 41.69 6.52 45.14 40.17 7,16
62(16.7) 60.44 60.44 4.45 58.18 58.18 4.90 55,72 ,; 55.72 _ 5.40 .53.10. 53.10 5.94 50.23 50.23 6.54 46.99 46.98.'` 7.18
57(13.9) 60.47 60.47 4.45 58.19 58.19 4.90 55.73 55.73 5.40 53.10 53.10 5.94 50.23 50.23 6.54 47.00 47.00' 7.10
NOTES:
*Tested combination.
t Total and sensible capacities are net capacities.Blower motor heat has been subtracted.
#Sensible capacities shown are based on 80*F(27°C)entering air at the indoor coil.For sensible capacities at other.than BO°F(27oC),deduct 835 Btuh
(245 kW)per 1000 CFM(480 US)of indoor coil air for each degree below 80'F(271C),or add 835 Btuh(245 kW)per 1000 CFM(480:US)of indoor coil air per-degree above 80°F(27°C).
#Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008.If additional tubing length and/or indoor unit is located above outdoor unit,a slight variation in capacity
may occur.
**System kw is total of indoor and outdoor unit kilowatts.
fit At TVA rating indoor condition(75°F edb/63°F ewb).All other indoor air temperatures are at 80'F ed-b.
NOTE:When the required data falls between the published_ data,interpolation may be performed.Extrapolation is not an acceptable practice.
EWB-Entering Wet Bulb
NOTE:When the required data fall between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. .
CONDENSER ONLY RATINGS*
SST CONDENSER ENTERING AIR TEMPERATURES-FCC)
°F('C) 55(12.78) 65(18.33) 1 75(23.89 85(29.44) 95(35.0) 108(40.56)' 1:15:(46,11)
•
TCG 16.90 15.70 14.60 1 13.60 1 12.60 1 10.50
30 9.30
_ SDT 71,20 79.70 88.40 97.90 107.30 126.60 137.10
KW 0.88 0.99 1.10 1.24 1.39 1.78
TCG 18.60 17.40 16.20 15.10 14.00 11,80 10.50
35 SDT 71.50 80,80 89.50 98.90 108.20 127.40 138.00
(1.67) KW 0.86 0.98 1.10 1.24 1.40 1.78 2.06
40 TCG 20.40 19.10 17.90 16.70 15.60 13.20 11,80
(4.44) SDT 73.50 81.90 90.60 99.90 109.20 128.70 137.60
KW 0.87 0.98 1.10 1.24 1.40 1,80 2,03
45 TCG 22.20 20.90 19.60 18.40 17.20 14.60 13.20
(722) SDT 73.40 83.10 91.70 101,00 110.30 129.40 138.50
KW 0.84 0.97 1.09 1.24 1.40 1.80 2.04
50 TCG 24,10 22.70 21.40 20.20 18.90 16.20 14.60
(10.0) SDT 74,30 83.50 92.80 102.10 111,40 130.40 139.50
KW 0.83 0.95 1,09 1.24 1.40 1.81 2.04
55 TCG 26.10 24.70 23.40 22.00 20.60 17.80 16.10
(12.78) SDT 75.50 84.80 94.00 103.30 112.50 131,50 140,30
KW 0.81 0.94 1.08 1.23 1.40 1.81 2.04
24A
TCG 18.60 18.00 . 17.40. 1 16.60 15.80 .14.90 13.80
(-30 SDT 78.20 87.90 97.80 107.70 117.70 127.80 138.10
KW 1,03 1.19 1.39 1.61 1.86 2.19 2.57
35 TCG 20.60 20.00 19.30 18.50 17.60 16.60 15.40
(1.67) SDT 79.80 89.50 99.30 109.10 119.10 129.20 139.30
KW 1.04 1.20 1.39 1.62 1.89 2.21 2.59-
40 TCG 22.70 22.10 21.30 20.50 19.50 18.40 17.20
(4.44) SDT 81.40 91.10" 100.80 110.60 120.50 130.50 t. 140.40
KW 1 A4 1.21 ' 1.40 1.64 1.91 2.23 2.60
45 TCG 25.00 24.30 23.50 22.60 21.60 20.40 19.10
(7.22) SDT 83.10 92.80 102.40 112.10 121.90 131.80 141.60
KW 1.04 1.21 1.41 1.65 1.92 2.24 2.62
50 TCG 27.50 26,70 25,80 24.90 23.80 22.50 21.10
(10.0) SDT 84.90 94.50 104.00 113.60 123.30 133.10 142.70
KW 1.05 1.22 1.42 1.66 1.93 2,26 2.63
TCG 30.10 29.30 28.30 27.30 26.10 24.80 23.30
55 - SDT 86.70 96.20 105.70 115.20 124.80 134.40 143.90
(12.78) KW 1.05 1.22 1.43 1.66 1.94 2.27 2.64
�•s
30 TCG 26.40 24.90 `23.20 1 21.70 20.20 18.70 17.10
SDT 71.50 80.00 88.80 98.10 107.40 116.70 126.00
KW 1.43 1.58 1.75 1.95 2.18 2,44 2.74
35 TCG 28.80 27.50` 25.50 23.90 22.20 20.60 19.20
(167) SDT 71,70 81.30 89.90 99.20 108.40 117.70 127.20
KW 1.41 1.58 1.75 1.96 2,19 2.45 2.76
40 TCG 31.90 29.60 27.90 26.20 24.40, 22.60 20,70
(4.44) SDT 73.40 82.00 91.20 100.30 109.50 118.70 127,90
KW 1.42 1.57 1.76 1.96 2.20 2.46 2.77
TCG 34.60 32.60 30.50 28.60 26.60 24.60 23.30
45 SDT 74.50 83.50 92.50 101.60 110.70 119.70 129.40
(7.22)
KW 1.42 1.58 1.76 1.97 2.20 2.47 2.60
50 TCG 37.40 35.60 33.40 31.10 29.00 26.70 25.40
(10.0) SDT 75.80 85.00 94.00 102.90 111.90 120.90 130.50
KW 1.41 1.59 1.77 1.97 2.21 2.48 2.81
TCG 40.80 38,60, 36.10 33.80 31.50 29.10 28.00
55 SDT 77.50 86.50 95.30 104.30 113.20 122.10 132.00
(12.78) 1.41 1.59 1.77 1.98 2.22 1 2.49 2.83
See notes on page 18
16
CONDENSER ONLY RATINGS* CONTIINUED
SST CONDHNSER ENTERING AIR TEMPERATURES°F(°C)
30 TCG 30.70 .28.50 .26.70. 25.10 23.50, 21.90 20.00
(_1.11) SDT 70.70 80.00, 89.40 98.80 108.20 117.60 127.00
KW 1.61 1.94 221 2.47 2.73 3.03 3.41
35 TCG 33.70 31.40 29.50' 27.80 26,10 24.30 22.20
(167) SDT 71.80 81.10 90.40 99.80 109.20 _ 118.50 127.80
KW 1.58 1.91 2.19 2.45 2.72 3.03 3.41
40 TCG 36.90 - 34.60 32.50 30.70 28.80 26.80 24.60
(4.44) SDT` 72.90 82.20 91.50 100.90 110.20 119,40 128.60
KW' 1.55 1.89 2.17 2.44 2.71 3.02 3.41
45 TCG 40.40 37.90 35.80 33.80 31.70 29.50 27.10
(7.22) SDT' 74.20 83.40 92.70 102.00 111.20 120.40 129.50
KW 1.53 1.87 2.16 2.43 .2.71 3.03 3.41
50 TCG 44.20 41.60 39.30 3710 34.80 32.40 29.80
(10.0) SDT 75.50 84.70 94.06 .103.20 112.30 121.40 130.50
KW 1.52 1.86 2.16 2.44 2.72 3.04 3.43
55 TCG 48.20 45.50 43.00 40.60 38.10 35.50 32.60
(12.118) SDT 77.00 86.10 95.30 104.40 113.50 122.50 131.50
KW 1.52 1.87 2.17 2.45 2.74 3.07 3.46
d r
30 TCG 38.00 36.00 1 33.90 31.90 29.70 .27.60 25.30
(-1.11) SDT 73.20 82.30 41.40 100.60 169.80 119.10 •- : 128.40
KW 1.95 2.20 2.48 2.80, 3.14 3.53 3.95
35 TCG 41.90 39.70 37.40 35.10 32.60 30.50 > 28.00
(1.67) SDT 74.80 83.70 92.80 101.90 111.00 120.20 129.40
KW 1.97 2.22 2.50 .2.81 3.16 3.54 3.97
40 TCG 46.00 43.60 41.10 38.70 1 36.20 33.60 30.90
(4-44) SDT 76.40 85.20 94.20 103.20 112.20 121.30 130.40
KW 1.98 2.23 2.52 2.83 3.18 3.56 3.98
45 TCG 50.30 47.70 45.10 42.40 39.60 36.80 33'.90
(7,22) SDT 78.10 86.90 95.70 104.60 113.50 122.50 131.40
KW 2.01 2.26 2.54 2.85 3.19 3.58 4.00
50 TCG 54.90 52.10 49.20 46.20 43.20 40.20 37.00
(10,0) $DT 80.00 88.60 97.20 106.00 114.80 123.70 132.50
KW 2.03 2.26 2.56 2,87 3.21 3.60 4.01
55 TCG 59.70 56.60 53.40 50.20 46.90 43.50 40.10
(12.78) SDT 81.90 90.30 98.90 107.50 116.20 124.90 133.60
KW 2.06 2.30 2.58 2.89 3.23 3.62 4.03
30 TCG 1 39.10 1 37.90 '36.60 35.10 33.40 31.50 29.40
(_1.11) SDT 72.80 82.00 91.40 100.60 110.00 119.20 128.40
KW 2.02 2.26 2.58 2.98 3.45 3.99 4.60
35 TCG 43.00 41,70 40.20 38.60 36.80 34.80 32.60
(167) SDT 74.20 83.40 92.60 101.90 111.10 120.30 129.40
KW 2.04 2.29 2.61 3.01' 3.49 4.03 4.64
40 TCG 47.20 45.80 44.20 42.40 40.50 38.30 35.90
(4-") SDT 75.80 84.90 94.00 103.20 112.40 121.50 130.50
KW 2.06 2.31 2.64 3.05 3.53 4.08 4.69
45 TCG 51.80 50.20 48.40 46.50 44.40 42.10 39.50
(7.22) SDT 77.40 86.50 95.50 104.60 113.70 122.70 131.70
KW 2.08 2.34 2.67 3.08 3.57 4.12 4.73
60 TCG 56.70 54.90 53.00 50.90 48.60 46.10 43.30
(10.0) SDT 79.20 88.10 97.10 106.10 115.10 124.00 132.90
KW 2.10 2.36 2.70 3.12 3.60 4.16 4.77
TCG 62.00 60.00 57.90 55.60 53.10 50.30 47.20
55 SDT 81.10 89.90 98.80 107.70 116.60 125.40 134.20
(12.78) KW 2.11 2.38 2.73 3.14 3.63' 4.19 4.81
See notes an page 18
17
CONDENSED ONLY RATINGS* CONTINUED
SST ICONDENSER ENTERING AIR TEMPERATURES°F(°C)
°F(-C) 1 55(12.78) 1 01118.33j 75(23.89) 85(29."), 95(35.0) 105(40.56) 115(46.11
24ABB360AON34
30 TCG 53.70 51.10 48.30 45.40 42.30 39.20 1 36.10
(-1.11) SDT 75.80 84.90 94.10 103.10 112.20 121.30 130.40
KW 2.65 3.00 3.38 3.78 4.24 4.77 5.38
TCG 58.90 56.10 53.00 49.80 46.50 43.20 39.70
35 SDT,, 77.50 86.60 95.70 104.70 113.60 122.60 131.60
(1 KW 2.72 3.08 3.43 3.84 4.29 4.82 5.44
40 TCG 64.60 61.40 58.00 54.50 50.90 47.20 43.40
SDT. 79.40 88.40 97.30 106.20 115.10 124.00 132.90
(4.44) KW 2.79 3.13 3.50 3.90 4.35 4.88 5.50
TCG 70.60 67.00 63.30 59.40 55.50 51.40 47.30
(7.5 SDT 81.40 90.30 99.10 107.90 116.70 125.40 134.20
KW 2.87 3.20 3.56 3.97 4.42 4.95, 5.56
50 TCG 76.90 73.00 68.80 64.60 60.20 55.70 51.20
(10.0) SDT 83.50 92.20 100.90 109.60 118.30 126.90 135.60
KW, 2.95 3.29 3.64 4.04 4.50 5.03 5.64
TCG 83.60 79.20 74.60 69.90 65.10 60.20 55.20
55 SDT 85.80 94.30 102.90 111.40 119.90 128.50 137.00
(12.78) KW3.05 3.38 3.73 4.13 4.59 5.12 5.73
MH i listing applies•only'to systems shown iri Combination Ratings table. - •
KW - 'Outdoor Unit Kilowatts Only.
SDT - Saturated Temperature Leaving Compressor(°F/°C).
SST - Saturated Temperature Entering Compressor(°F/°C)
TCG - Gross Cooling Capacity(1000 Btuh)
18
r
GUIDE SPECIFICATIONS AIR-COOLED,SPLIT=SYSTEM AIR•CONDITIONER
24ABB3
GENE 1-1/2 TO 5 NOMINAL TONS
System Description Condenser Coil
Outdoor-mounted, air-cooled, split-system air conditioner unit — Condenser coil will be air cooled.
suitable for ground or rooftop installation. Unit consists of a — Coil will be constructed of aluminum fins mechanically
hermetic compressor, an air-cooled' coil', propeller-type bonded to copper tubes which: are then cleaned,
condenser fan, and a control box.Unit will discharge supply air dehydrated,and sealed.
upward as shown on contract drawings. Unit will be used in a ' Refrigeration Comnonents
refrigeration circuit to match up to a packaged fan coil or coil
unit. Refrigeration circuit components will include
Quality Assurance liquid-line shutoff valve with sweat connections,
vapor-line shutoff valve with sweat connections,
Unit will be rated in accordance with the latest edition system charge of Puron@ (R-410A) refrigerant, and
of AHRI Standard 210. compressor oil.
— Unit will be certified for capacity and efficiency, and — Unit will- be equipped with filter drier for Puron
listed in the latest AHRI directory. refrigerant.
--- Unit construction will comply with latest edition of Operating Characteristics
ANSI/ASHRAE and with NEC. — The capacity of the unit will meet or exceed
— Unit will be constructed in accordance with UL Btuh at a suction temperature of °F/°C. The
standards and will carry the UL label of approval.Unit power consumption at full load will not exceed
will have c-UL-us approval. kW.
— Unit cabinet will be capable of withstanding Federal — Combination of the unit and the evaporator or fan coil
Test Method Standard No. 141 (Method 6061)500-hr unit will have a total net cooling capacity of
salt spray test. Btuh or greater at conditions of CFM entering
— Air-cooled condenser coils will be leak tested at 150 air temperature at the evaporator at °F/°C wet
psig and pressure tested at 450 psig. bulb and °F/°C dry bulb, and air entering the
— Unit constructed in IS09001 approved facility. unit at °F/°C.
Delivery,Storage,and Handling — The system will have a SEER of Btuh/watt or
Unit will be shipped as single package only and is greater at DOE conditions.
stored and handled per unit manufacturer's Electrical Requirements
recommendations. — Nominal unit electrical characteristics will be^v,
Warranty(for inclusion by specifying engineer) single phase, 60 hz. The unit will be capable of
U.S.and Canada only. satisfactory operation within voltage limits of v
to V.
PRODUCTS — Nominal unit electrical characteristics will be v,
Equipment three phase, 60 hz. The unit will be capable of
Factory assembled, single piece, air-cooled air conditioner unit. satisfactory operation within voltage limits of v
Contained within the unit enclosure is all factory wiring,piping, to V.
controls, compressor, refrigerant charge Puron® (R-410A), and — Unit electrical power will be single point connection.
special features required prior to field start-up. — Control circuit will be 24v.
Unit Cabinet Special Features
— Unit cabinet will be constructed of galvanized steel, — Refer to section of this literature identifying accessories
bonderized,and coated with a powder coat paint. and descriptions for specific features and available
— All models have dense grille. enhancements.
Fans
— Condenser fan will be direct-drive propeller type,
discharging air upward.
— Condenser fan motors will be totally enclosed,1-phase
type with class B insulation and permanently lubricated
bearings.Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated
steel wire safety guards.
Compressor
— Compressor will be hermetically sealed.
— Compressor will be mounted on rubber vibration
isolators.
19
SYSTEM DESIGN SUMMARY
1: Intended.for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0:01-in,wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F(12.8°G).
3. Maximum outdoor operating air temperature is 115'F'(4'6.1-C).
4. For reliable operation,unit should be level m all horizontal planes.
5. For interconnecting refrigerant tube lengths greater than 80 ft(23.4 m)and/or 35 ft(10.7 m)vertical differential,consult Residential
Piping and Longline Guideline and Service Manual available from equipment distributor.
6. If any refrigerant tubing is buried,provide a 6 in. (152.4 mm)vertical,rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in.(914.4,mm)`may be buried without further consideration.Do,not bury refrigerant lines longer than 36 in..(914.4
7. Use only coppet,wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the,type,of connector.
provided.
8. Do not apply capillary tube indoor coils to these units.
9:Factory-supplied filter drier;must be installed:.
Copyright 2016 Carrier Corp.-7310 W.Moms St• Indianapolis,IN 46231 Edition Date: 12/16 Catalog No:24AS83-15PD
rrra�r� n i�ra
Manufacturer reserves the right to change,at any time,specifications and designs without notice and without obligations. Replaces:24AB03-14PO
20