HomeMy WebLinkAbout47528-Z �O�SUFF01 o Town of Southold 5/26/2022 a P.O.Box 1179 0 v' 53095 Main Rd oy 8p fi Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43101 Date: 5/26/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 2950 Vanston Rd, Cutchogue SCTM#: 473889 Sec/Block/Lot: 111.-5-7.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/10/2022 pursuant to which Building Permit No. 47528 dated 3/8/2022 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. (Maintain proper clearances) The certificate is issued to Riley JP Jr 2002 Fain GST Tr of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47528 4/18/2022 PLUMBERS CERTIFICATION DATED Author ed Signa e �suFfnt,r�o TOWN OF SOUTHOLD ' BUILDING DEPARTMENT z TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47528 Date: 3/8/2022 Permission is hereby granted to: Riley JP Jr 2002 Fam GST Tr 136 E 79th St Apt 10B New York, NY 10075 To: Install generator at existing single family dwelling as applied for. At premises located at: 2950 Vanston Rd, Cutchogue SCTM #473889 Sec/Block/Lot# 111.-5-7.2 Pursuant to application dated 2/10/2022 and approved by the Building Inspector. To expire on 9/7/2023. Fees: ACCESSORY $100.00 CO-RESIDENTIAL $50.00 Total: $150.00 Building Inspector o��oF so�ryol � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.deviinR-town.southold.ny.us Southold,NY 11971-0959 OIyCoUNN,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Riley JP Jr 2002 Fam G S T Tr Address: 2950 Vanston Rd city,Cutchogue st: NY zip: 11935 Building Permit#: 47528 Section: 1 1 1 Block: 5 Lot: 7.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GJS Electric License No: 4839ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 300A UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED El Exit Fixtures Pump Other Equipment: 38kW Generator w/ 300A Transfer Switch 175A Overcurrent on Generator Notes: " AS BUILT NO VISUAL DEFECTS " Generator Inspector Signature: Date: April 18, 2022 S.Devlin-Cert Electrical Compliance Form OF SOUlyolo - * TOWN OF SOUTHOLD BUILDING DEPT. cou765-1802 INSPECTION . [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] -FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] -FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) N 'ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE /C/O r�� A REMARKS: DATE q 116121, INSPECTOR G-- *�oE SO(/T�O# TOWN OF SOUTHOLD BUILDING DEPT. �yco 631-765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING FINAL &QZX- l+Tci2 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O [ ]' RENTAL REMARKS: �J ly164�,rrr�g ,y P, �G�, CLE�r_ c� F .��c DATE INSPECTOR Z � — FIELD INSPECTION REPORT DATE COMMENTS ►d FOUNDATION(IST) H ------------------------------------- FOUNDATION(2ND) t� mom ROUGH FRAMING& y PLUMBING N 3 INSULATION PER N.Y. H STATE ENERGY CODE • fi S-i3-7—z eyz P�O�I' CGE�r �� ��o�.Um GEti��is�ar� U,/4� Foto C FINAL ADDIT ON41,COMMENTS 0 C Cq S� ZZ 14—b /'a f e o c �ro + o z H d b H. °SufFoek�oG TOWN OF SOUTHOLD—BUILDING DEPARTMENT y a Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 hMs://www.southoldtownn .gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only L.D / '•- -�� ~ �'� PERMIT NO. / / Building Inspector: IJ ll FEB 1 0 2022 applications will not be accepted. Where the Applicant is not theow Applications and forms must be filled out in their entirety. Incomplete 'owner,an Owner's Authorization form(Page 2)shall be completed. `F` Y .'`-OF S01.3"'. Date:2/10/2022 .OWNER(S)OF.PROPERTY: Name^The Shannon Riley Trust_ scTM#1000-111-05-7.2 Project Address:2950 Vanston Road,Cutch ogue NY 11935 Phone#:631 484-9763 Email:bur9 erconstruct aol.com Mailing Address:Burger Const., PO Box 934, Cutchogue NY 11935" CONTACT PERSON: Name:Eugene Burger �� Mailing Address:PO Box 934, Cutchogue, NY 11935 Phone#:631 484-9763 _ _Email:burgerconstruct@aol_.com DESIGff PROFESSIONAL INFORMATION: Name:Fred Weber Mailing Address:41 East Maple Road,_Greenlawn,_NY 11740 Phone#:6.31 754-5555 Email:fweberarchitect@yahoo.com,_ _ CONTRACTOR INFORMATION: Name:Burger Construction Mailing Address:PO Box 934, Cutchogue,, NY 11935 Phone#:631 484-9763 -_ E.mail:bur9 erconstruct aol.com DESCRIPTION OF'PROPOSED CONSTRUCTION ®New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other New Generator $10,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to O this property? Dyes Ao IF YES, PROVIDE A COPY. ❑ Check Box After Reading; The owner/contractor/design professional is responsible for ill-drainage and.storm water issues as provided by ., Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County;Newyork and other applicableLaws,Ordinances or Regulations;for the construction of buildings, additions,'alterations or for removal or demolition as herein described.the applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)'for necessary inspections.False statements made herein are punishable as aFClass A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): - _ uthorized Agent El Owner Signature of Applicant: Date: l C� STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the CO N 7-6- -L T•D ie 19-1V4 146-,E-4/7- (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work OIddIIMl �nd file this application;that all statements contained in this application are true to the best of his/he,�` AwkXM,4 -"Il lief;and that the work will be performed in the manner set forth in the application file therewith����; e>suF�oZ ••yam 2cre. co•: G Sworn before me this cY:o' NOTARvY O-PLIBL $ w.o� feeso�'`'AC day of 20�- '`` ;���``•' 4-V Nofa, y If b NO ���f111111111t���` PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) I, 4.L. EAl <�f If L C Y residing at �36 L—�, G 1�,� JT. New Jd iPK) �V f 0o 7s— do hereby authorize EU d-&W G &LR 6-,r/Z to apply on m�fpehalf to the Town of jbuthold Building Department for approval as described herein. Owner's Signature Date ( %L V Print Owner's Name 2 ©sl Fftl(`, BUILDING DEPARTMENT-Electrical Inspector TOWN;OF SOUTHOLD Town Hall Annex= 54375 Main Road - PO Box 1179 v' Southold, New York 11971-0959 Telephone.(63:1) 765-1802.- FAX (631).765-9502 rogerr(d).southoldtownrl goy­seandO-ssbutholdtownny:gbv'. APPLICATION FOR.ELECTRICAL INSPECTION 1 ELECT R�CI Rik FORMATIONk(All°Inforrriation Required) s flats: Company'N me: , C2. tiG L Name: 0� Livens No.: email: n . V,'(-o/yq Phon :No:0-a -;qic, request an email tropy of Certificate of Compliance JOB-SITE_I FORMATION (Ali Informafaon Required) Aci rens: d, D. Y Cross.S f6dt: �d 2 P bn No14 Bldg`Pe It#` email: c, Tax__Mtap,-Dl trlct_, X000 . .. ..:.Se ::_l-.. ... .. .. . ,Block C��r...... ..... ... .. .Lo# 7-.,�. ...:. : ..... B tEF DESCRIPTION 01=VI/ORI�:(Please.Pnnt,,Clearly) ' C fY10�1�= 77777-V7. .7 Check All iTh t Apply: YES NO ou h IstQb;ceady_f.r inspection?: . .. ❑ 1!s.. .9...,. ... 0., Do you:.need Temp Certificate? YES,., �NO Issue dri s r Temp:Inform tion: (All information required) Serv1 `e Size Ph . 03'Rh .Size:..�o- ..A. #Meters .. . . . , ... Old,Meter# . :....., ` lew.Service ❑ Service Reconnect Underground F1 Overhead' z• #Underground Laterals .Q1 Q2: Frame' Pole Work done on Se ..' QY ❑N Additional Information: PAYMENT DUE WITH APPLICATION � . • .. Pd 5-��'-a J . Electrical Inspe(tion Form 202OAsx i I ,sT� 1 APPROVED AS NOTED OCCUPANCY OR DATE:S'0-22- B.P.#. USE IS UNLAWFUL FEE: GD•c7-D BY: WITHOUTlJITHOUT CERTIFICATE NOTIFY BUILDING DEPARTMENT AT OF OCCUPANCY 765-1802 8 AM TO 4 PM FOR THE L� FOLLOWING INSPECTIONS: 1. FOUNDATION.:=-TWO* REQUIRED FOR .POURED.`CONCRETE .. 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL'`- CONSTRUCTION MUST BE•COMPLETE FOR C.O. COMPLY WITH ALL;CODES OF ALL CONSTRUCTION SHALL--MEET THE NEW YORK-STATE_& TOWN CODES REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR AS REOUIR AND:`COND,ITIONS OF DESIGN OR ~CONSTRUCTION ERRORS. SOUTHOLDTOWN ZBA SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y.S.DEC CAL W a� RETAtN STORM WATE ERU236FF PURSUANTWN Go"'THE W GENERAC® 0 Protector® QS PROTECTOR° QS SERIES Series Standby Generators Liquid-Cooled Gaseous Engine INCLUDES: Standby Power Rating • Two-Line LCD Multilingual Digital Evolution T1 Model RG022 (Aluminum - Bisque) -22 kW 60 Hz Controller (English/Spanish/French/Portuguese) Model RG027 (Aluminum - Bisque) -27 kW 60 Hz with external viewing window for easy indication of Model RG032 (Aluminum - Bisque) -32 kW 60 Hz generator status and breaker position. Model RG038 (Aluminum - Bisque) -38 kW 60 Hz • True Power" Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System GE1 E • Smart Battery Charger ; • UV/Ozone Resistant Hoses '= • ±1%Voltage Regulation • Natural Gas or LP Operation =c } • 5 Year Limited Warranty • UL 2200 Listed • SwRi® listed (NFPA37, clause 4.1.4.1.2) Generator can be installed a minimum 18 in c 1 os QUI EFEST- distance from combustible wall* LJnkle �/ 'AssrJMLtl b Na USC using Eum¢IIuvNlmuiyiput *Only if located away from doors,windows,and fresh air intakes, Meets EPA Emission Regulations and unless otherwise directed by local codes.Please review 22&27 kW are CA/MA emissions compliant install guide for more details. 32&38 kW not for sale in CA/MA FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't REGULATION. This state-of-the-art power maximizing regulation stop there. Total commitment to component testing, reliability testing, system is standard on all Generac models.It provides optimized FAST environmental testing, destruction and life testing, plus testing to RESPONSE to changing load conditions and MAXIMUM MOTOR applicable CSA, NEMA, EGSA, and other standards,allows you to choose STARTING CAPABILITY by electronically torque-matching the surge GENERAC POWER SYSTEMS with the confidence that these systems will loads to the engine.Digital voltage regulation at±1%. provide superior performance. O TEST CRITERIA: O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive ✓PROTOTYPE TESTED ✓NEMA MG1-22 EVALUATION dealer network provides parts and service know-how for the entire unit, ✓SYSTEM TORSIONAL TESTED ✓MOTOR STARTING ABILITY from the engine to the smallest electronic component. O MOBILE LINK® CONNECTIVITY: FREE with all Protector Series Home O GENERAC TRANSFER SWITCHES. Long life and reliability are standby generators, Mobile Link Wi-Fi allows users to monitor generator synonymous with GENERAC POWER SYSTEMS. One reason for this status from anywhere in the world using a smartphone,tablet,or PC.Easily confidence is the GENERAC product line is offered with its own access information such as the current operating status and maintenance transfer systems and controls for total system compatibility. alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. GENERAC® GENERAC® r 22 • 27 • 32 • 38 application & engineering data GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS:22,27,32 &38 kW Type Synchronous Make Generac Rotor Insulation Class H(22&27 kW)or Model In-line F(32&38 kW) Cylinders 4 Stator Insulation Class H Displacement(Liters) 2.4 Telephone Interference Factor(TIF) X50 Bore(in/mm) 3.41/86.5 Alternator Output Leads 1-Phase 4 wire Stroke(in/mm) 3.94/100 Alternator Output Leads 3-Phase 6 wire Compression Ratio 9.5:1 Bearings Sealed Ball Naturally Aspirated(22&27 kW)or Coupling Flexible Disc Intake Air System Turbocharged/Aftercooled(32&38 kW) Excitation System Direct Lifter Type Hydraulic VOLTAGE REGULATION ENGINE LUBRICATION SYSTEM Type Electronic Oil Pump Type Gear Sensing Single Phase Oil Filter Type Full flow spin-on cartridge Regulation ±1% Crankcase Capacity(qVI) 4/3.8(22,27,32&38 kW) GOVERNOR SPECIFICATIONS ENGINE COOLING SYSTEM Type Electronic Type Closed Frequency Regulation Isochronous Water Pump Belt driven Steady State Regulation ±0.25% Fan Speed(rpm) 1,980-22&27 kW 1,500-32&38 kW ELECTRICAL SYSTEM Fan Diameter(in/mm) 18.122/558(8(32&38 kW) or Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Fan Mode Pusher(22&27 kW)or Puller(32&38 kW) Recommended Battery(battery not included) Group 26(22,27,32&38 kW) System Voltage 12 Volts FUEL SYSTEM GENERATOR FEATURES Fuel Type Natural gas,propane vapor Carburetor Down Draft Revolving field heavy duty generator Directly connected to the engine Secondary Fuel Regulator Standard Operating temperature rise 120°C above a 40°C ambient Fuel Shut Off Solenoid Standard Class H insulation is NEMA rated Class F insulation is NEMA rated LP Fuel Pressure 5-14 in Water Column All models fully prototyped tested NG Fuel Pressure 5—14 in Water Column ENCLOSURE FEATURES Ensures protection against mother nature. Aluminum weather protective enclosure Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. Small,compact,attractive Makes for an easy,eye appealing installa- tion. SAE Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514,ISO3046,ISO8528,SAE J1349 and DIN6271) GENERAC® 22 • 27 • 32 • 38 operating data _ 0 GENERATOR OUTPUT VOLTAGEAW-60 Hz kW LPG Amp LPG kW Nat Gas Amp Nat.Gas CB Size(Both) 120/240 V,10,1.0 pf 22 92 22 92 100 RG022 120/208 V,30,0.8 pf 22 76 22 76 80 120/240 V,30,0.8 pf 22 66 22 66 80 120/240 V,10,1.0 pf 27 113 25 104 125 RG027 120/208 V,30,0.8 pf 27 94 25 87 100 120/240 V,30,0.8 pf 27 81 25 75 90 120/240 V,10,1.0 pf 32 133 32 133 150 120/208 V,30,0.8 pf 32 111 32 111 125 RG032 120/240 V,30,0.8 pf 32 96 32 96 100 277/480 V,30,0.8 pf 32 48 32 48 60 120/240 V,10,1.0 pf 38 158 38 158 175 120/208 V,30,0.8 pf 38 132 38 132 150 RG038 120/240 V,30,0.8 pf 38 114 38 114 125 277/480 V,30,0.8 pf 38 57 38 57 60 SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION Voltage Dip @<.4 pf Natural Gas Propane 15% 30% (ft3/hr) (m3/hr) (gal/hr) (ft3/hr) (1/hr) 120/240 V,10 55 135 Exercise cycle 42 1.2 0.44 16 1.7 RG022 120/208 V,30 40 92 25%of rated load 100 2.8 1.1 40 4.2 120/240 V,30 35 80 RG022 50%of rated load 190 5.4 2.1 75 7.8 120/240 V,10 62 170 75%of rated load 255 7.2 2.8 101 10.5 RG027 120/208 V,30 70 120 100%of rated load 316 9 3.4 125 13 120/240 V.30 61 1 103 Exercise cycle 42 1.2 0.44 16 1.7 120/240 V,10 75 180 25%of rated load 108 3.1 1.2 43 4.5 120/208 V,30 87 210 RG027 50%of rated load 197 5.6 2.1 78 8.1 RG032 120/240 V,30 75 182 75%of rated load 287 8.2 3.1 114 11.8 277/480 V,30 36 87 100%of rated load 359 10.2 3.9 143 14.8 120/240 V,10 75 180 Exercise cycle 79 2.2 0.8 30 3.2 RG038 120/208 V.30 87 210 25%of rated load 144 4.1 1.7 60 6.3 120/240 V,30 75 182 RG032 50%of rated load 226 6.4 2.7 97 10.3 277/480 V,30 36 87 75%of rated load 298 6.4 3.7 132 13.9 100%of rated load 375 10.6 4.6 166 17.5 Note:Fuel pipe must be sized for full load. Exercise cycle 83 2.3 0.9 31 3.2 For Btu content,multiply ft3/hr x 2,520(IP)or W/hr x 1,000(NG) 25%of rated load 162 4.6 1.7 62 6.6 For megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG) RG038 50%of rated load 255 7.2 2.9 103 10.8 Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD 75%of rated load 1 345 9.8 4 142 15 permitting purposes. 100%of rated load 437 12.4 5.2 185 19 STANDBY RATING:Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads for the duration of a power outage.There is no overload capability for this rating.Ratings are in accordance with ISO-3046-1.Design and specifications are subject to change without notice. GENERAC® 22 • 27 • 32 • 38 operating data ENGINE COOLING 22 kw 27 kW 32&38 kW Air flow(inlet air including alternator and combustion air in cfm/cmm) 2,400/68 2,400/68 2,200/62.3 System coolant capacity(gal/liters) 2.5/9.5 2.5/9.5 2.5/9.5 Heat rejection to coolant(BTU per hr/MJ per hr) 99,000/104.5 105,000/110.8 145,000/153 Maximum operation air temperature on radiator(OF/°C) 140/60 ' Maximum ambient temperature(°F/OC) 122/50 COMBUSTION REQUIREMENTS Flow at rated power(cfm/cmm) 1 68/1.9 1 68/1.9 1 106/3 SOUND EMISSIONS Sound output in dB(A)at 23 ft(7 m)with generator in exercise mode' 61 61 58 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load" 70 70 64 EXHAUST Exhaust flow at rated output(cfm/cmm) 165/4.7 180/5.1 300/8.5 Exhaust temperature at muffler outlet(°C/°F) 482/900 1 538/1,000 579/1,075 ENGINE PARAMETERS Rated Synchronous rpm 1,800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration....................................................................................................................................................3%for every 10°C above 25°C or 1.65%for every 10°F above 77°F Altitude Deration(22&27 kW)....................................................................................................................................1%for every 100 in above 183 m or 3%for every 1,000 ft above 600 ft Altitude Deration(32&38 kW)..................................................................................................................................1%for every 100 in above 915 m or 3%for every 1,000 ft above 3,000 ft CONTROLLER FEATURES Two-Line Plain Text LCD Display............................................................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto................................................................................................................................................................................Automatic Start on Utility failure.7 day exerciser. Off.............................................................................................................................................................Stops unit.Power is removed.Control and charger still operate. Manual.............................................................................................................................Start with starter control,unit stays on.If utility fails,transfer to load takes place. Programmable start delay between 10—30 seconds.......................................................................................................................................................................................10 sec standard Engine Start Sequence..............................................................................................................................................................Cyclic cranking:16 sec on,7 rest(90 sec maximum duration) EngineWarm-up.............................................................................................................................................................................................................................................................5 sec EngineCool-Down..........................................................................................................................................................................................................................................................1 min Starter Lock-out.........................................................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. SmartBattery Charger................................................................................................................................................................................................................................................Standard Automatic Voltage Regulation with Over and Under Voltage Protection........................................................................................................................................................................Standard AutomaticLow Oil Pressure Shutdown........................................................................................................................................................................................................................Standard OverspeedShutdown.......................................................................................................................................................................................................................................Standard,72 Hz HighTemperature Shutdown..................................................................................................................................................................................................................................... Standard OvercrankProtection....................................................................................................................................................:.............................................................................................Standard SafetyFused..............................................................................................................................................................................................................................................................Standard Failureto Transfer Protection......................................................................................................................................................................................................................................Standard LowBattery Protection................................................................................................................................................................................................................................................Standard 50 Event Run Log.......................................................................................................................................................................................................................................................Standard FutureSet Capable Exerciser..................................................................................................................................................................................................................................... Standard IncorrectWiring Protection........................................................................................................................................................................................................................................ Standard InternalFault Protection..............................................................................................................................................................................................................................................Standard CommonExternal Fault Capability..............................................................................................................................................................................................................................Standard GovernorFailure Protection....................................................................................................................................................................................................................................... Standard REMOTE MONITORING • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. FILTER CLOTH AGAINST WOVEN WIRE FENCE W/ STORM WATER POLLUTION PREVENTION 74"44` STAKES, 12' OC CONCRETE LOT 31� FREDERICK DRIVEN 16" MIN. INTO COVER OR GRADE, EMBED FILTER' TRAFFIC C.I. GRATE AMENDED MAP A" CSF ROBERT CLOTH 4" INTO GROUND NASSAU POINT CLUE3 PROPERTIES, INC. WEBER CONSTRUCTION PHASING: BEARING I- INSTALL HAY BALE/SILT FENCE. TRAFFIC SLAB PRECAST ASPHALT CONCRETE SECTION C 2- CONSTRUCT NEW PORCHES. TERRACES. PATIOS, ETC. Top BEARING A CHIMNEY 3- INSTALL DRAINAGE STRUCTURES AND NEW SANITARY SYSTEM 6«� FILE No. 154 FILED AUGUST IL. 1922 p z " PIPE TRENCH DRAINAGE ARCHITECT 4- PROVIDE GUTTERS/LEADERS AND CONNNECT TO DRAINAGE STRUCTURES. FLOW n SITUATE _ DRAIN TO PIPE � NASSAU POINT SLOPE ,� •• DRAINAGE RING INSPECT HAY BALE/ SILT FENCE WEEKLY `' STONE BLEND t,-, i TOWN OF SOUTHOLD BUILDABLE SITE AREA: 29.152 SF, LAND DISTURBANCE: 10.000 SF I TYPICAL DRAINAGE i SUFFOLK COUNTY. NEW YORK EXISTING CONDITIONS: SITE IS MOSTLY CLEARED IN AREA OF CONSTRUCTION t CROSS SECTION CROSS SECTION , RING > S.C. TAX No. 1000-III-05-1.2 DRIVEWAY. SITE PITCHES TOWARD WATER. CLEAN FILL WILL BE BROUGHT IN FOR SILT FENCE DETAIL TRENCH DRAIN DRIVEWAY i I SANITARY SYSTEM IF REQUIRED.-BUT EXPECT EXCESS FILL FROM SANITARY I W SYSTEMS AND DRAINAGE STRUCTURE WILL BE REMOVED. CONSTRUCTION ENTRANCE AND STAGING AREA WILL BE EXISTING DRIVEWAY AREA. 2' CLEAN SAND t _mss REMOVE TOPSOIL OVER PROPOSED PORCH ADDITIONS, SANITARY SYSTEM, BOUND HAY BALE �_____ GRAVEL FILL -----__-j ,� z I DRAINAGE RINGS. STOCKPILE AND RE-SPREAD OVER COMPLETED SYSTEMS. FILTER CLOTH AGAINST PLACED ON CONTOUR WOVEN WIRE FENCE W/ W/ 20X2" STAKES (1.5'-2' 2"x2"x36" STAKES. 12' OC IN GROUND) DRIVE STAKES TYPICAL SECTION DRAINAGE RING O DRIVEN IL" MIN. INTO FLUSH W/ TOP OF HAY '� EXCAVATION/FILL GRADE, EMBED FILTER BALE. ANGLE FIRST STAKE CLOTH 4" INTO GROUND TOWARD PREVIOUSLY LAID / z H BALE EXCAVATION FOR SANITARY t DRYWELLS = 100 CY GQ O BACKFILL FOR RAISED PATIOS, TERRACE t SCREEN PORCH = 30 CY FLOW n �/ 134 , O z SLOPE e ,. .a "/ �'`., �;• � z II II �� II �� •. SITE DRAINAGE: V v v �opER,�F\5"'�R CROSS SECTION FACE VIEW PQ ASF= W DR# AREA VOLUME (Required) DRAINAGE STRUCTURES VOLUME (Provided) HAY BALE � SILT FENCE DETAILS 0, � SURVEY INFORMATION: H �aa - >R1 PARTIAL HOUSE, REAR 994 sf (Partial Hoose) + LT1 of (Rear Parches, (I) 8' Dia. x 8' Deep o/ 338 cf .-' > SURVEY INFORMATION: PORCHES. PATIO t SPA Patio. Spa) = IL13 of x J41 = 219 cf Traffic Bearing Slab r � 9 � Pr 8" TWIN FORKS LAND SURVEYING / / O I Trc Dram 188 W. MONTAUK HGWY.. UNIT E3 >r2 PARTIAL HOUSE, FRONT 15K of 1Patio/Walk) + 103 of (Front Porth) + (l) 8' Dia. x 14' Deep Ili/ 422.5 cf J,,- / � HAMPTON BAYS. NEW YORK PORCH. PATIO, WALK 858 at (Partial House) = 2411 at x Al = 4N Traffic Bearing Slab „ � • �- DRIVEWAY. GARAGE. 2881 st (Dnvevsy + Ill sf (Garage/Cottage) (2) 8' Dia x 10' De a/ 'C 00 ' • ' // SURVEYED: AUGUST�8. 2020 #3. #4 eP 845 cf O r ` ELEVATIONS REFER TO NAVD 1988 COTTAGE. PATIO + 184 ar (Patio) = 4238 of x Al = 108•ct Traffic Bearing Slabs � I.a • • , /' �!� �, / • r Rewe E>a,tng� // �% �' METES t BOUNDS ARE AS PER L.12103 P.891 2/23/2001 / `" �►� o� �yL // - &/ i i FLOOD ZONE BOUNDARIES HEREON ARE AS DEPICTED ON THE z Hage. Garage/Cottage and Porch Roofs to have Gutters t Leaders ��' -'� - '� ••' �^ �` � Connected to Underground Drainage Structures (Tgp.) ,� - GI /` , i q, ,p F.E.M.A. FLOOD INSURANCE MAP 8'0 Ring: 42 25 cf/Ft of Height I r 111 / n / �, „� � Os MAP NO. 34103CO144 H -EFFECTIVE SEPTEMBER 25. 2009 IO'WIDE `! NON-TURF / ., ! ` 6aat,ng F� . =' Pr \`` n JRd&v g fall - --- Baem�mo i` PROPOSED �,, /y Rewe F trng �, (° SITE I N F O R M,4 T I O Irl r s a�' -- - '------ a �,RYEL ti Dnv 1 �� / ff/ match i� - LAwN nI DRIV X. sem- '�1 �6W-4) Catch Y y -0 , -.,:a«!"""'. ' . S avet`w! Vegeta eg ,,'- , ( `%_� Beam ,, i f' I I LOT AREA = 29152 sq. ft. . ::.: ., 12•%5 t DW-2 -'j Rowe I '1 \ o �O :;� :ar::: ; ::.. ti, eve..: B �p �• , i u I 1 y I . (TO TIE LINES) 0.683 ac. Q Tn a z:: ::; bmt.Pato , tid 1 '' � J J J r :x........... 14 .• ` ::... ..::.::............. , ` r J _ • ... S - a �- - . � PROPOSED ALKExdn Tree � � P� J �' PROPOSE steps r3g1-sF�- g•yu ��� 101111 " O/ �etenng to (Too ZONING: R-40 (NON-CONFORMING LOT DRAWING TITLE: N " • :r - •�rFXHaee tofY•••� '� e I ♦ PATIO F Prapoeed •• �\ ( n M I I I 20 000 TO 39,999 SF) , ud°kheaed u, ? Prapaegd , apaa ♦111�s sF,; „ , , ,. .._ . to Renm,i o r::- : :;: I M s ! Lane ` �'t:xP,: wand tpe . �'� , ♦♦ It (� I ' �;•POLE I n N = , 24 ,- + c. g ♦ l,— _ ew '� ----- 1 I 1 .� I i INCIPAL) �� _ YARDS: (PR SITE PLAN N ....� r{' µyx..:.#. t,Kk t0••r•1 ,N,O ' tKtK i I -`f PROP ! J• Y tIASONRY APROTI� u n FRONT 40' TEST O DATA r �' : - .......:.. _ NE111 LAWN~ Cry_. ed t , /• I , t I SIDE (ONE): 15 .... = = 5 HOLE ao ` #: - . .: _ ... g.. OV P IAL s K Pr _�3: ` Jsa°°nFs ' °p°°e ��' • \ \ I ► SIDE (BOTH): 35' '";- S - TER t • EPLA (� F,+, ♦ andsca '" .. / rIBA-S� \Ste s t , , a n' IL y "r;: ` ''•' �L ' ROP ED ET TING€2ND I Yeiie , , , I \ REAR: 50 McDonald GeoServices �c I -- t LP1 A _ Januarg, 21, 2021 ,nl s o E�aa 1 P a/ PATIO FL�oR c+c, El+n9 NIB n a+2u O ' I t t .�► sl:;;.`... g rel_ � i C,�h , / \ 1 � 1 / EL 21' (+/-) tY 1 Resartt, '3 SF) 1 , E�XtS NG -- �of I Pr �ar°c• ►' \ t�fi©R1 t i 1�, f HEIGHT ( RIES of o , er t i ISTI , •�p p 1 •p LOT C AX.) P- �"' v G ti \ I /fit' T 1 t >;' I :< I Ir' �n SINGL FAMI Y t 11 1 i OTT .� Gtr LOT 31� t 1 t O_ Brown Sdtg s,�! 3 m z iu- ._ . _ i i I/A OWTSi 1 1 1 y Sand SM ,� �; .0 �' ' J �T T ':: :. - DWEL NGR___"- IO' o TREATME T •1 1=F E + s' ' BOARD OF IRUSTEES s.3 \ / qac NSpd to Tx l,ne _:_..:.. 1-5TORY i O A 0- GA +Z'f.9 p \ 1 1 \ 1 J013: O o v To�, BN FF L + i TANK 1 J PRdPO 15 5 P 3 i g o 'Ce h 1 ` TOWN OF SOUTHOLD u"� r e8' ea sA =>_t;<:. _ :� _ P ' '-0 -- i • 1 t 1 1.� Q o ' c'il ( •e�'t�•i:� `- rs:: ..sP .IK rJ.... ..+ 8'°P i p col --_-- } ' w� , an , = firan!BaN/Stal Edge l5 l�J u w , � ►=< <� t.� T RAC , ,. � � .,, ,, � 1 Hs�le'' � \ `\ SHANNON RILEY p Etmg -; 200 SFr, r DATE ® _ _______ __ D ______ O ti` ``. :• Gravel Bed/St Gravee®ed .t ee n Qoncrete ,�:: : r 1 ," \\ g h )Bulkhead , t LAWN -- - ---- ----------y- -- i' /` roperta Low 1 • \ '' ` ��- I z( PORCHES/PATIOS Pale Brown •'C h .s to Reaurn tDW-I - LA i Steps •• —B -- • . • , t Gra. \ MAR 29 1 \ .,C r _ r ew I 1 t 5 50 VAN5TON ROAD Fine Sand • :,: : ::::;:' I I Propaeed+landecape V ___ SP • J / % '�, . �;. :; y Proposed R' mall � ,,,,„�.�,.,.,,,, ,_�,,, ..,.,,„.«..,. (NASSAU POINT) / o \�1� ' / / J I ► CUTCHOGUE. NY \z1� %.T'PENCE , 31$.00' ►�' r r I Southold Town i % 49 a' IUIDe L�. natllhlrt S 82° 13' 10' W \��� 11a, �� �. NIDTH NATIVE Board of Tn�stees TOWN OF SOUTHOLD SCTM>x 1000-I1I-05-1.2 NTR F PLANTINGS J LOT 31G 1.p7 311 LOT COVERAGE: BUFFEr ARCHITECT: 11' Encoountered % a f ! EXISTING / APPROX. LOCATION I EXISTING HOUSE: 1854 5F FREDERICK R. WEBER OF EXISTING SANITARY / NORTH EXISTING FRONT PORCH: 103 SF 41 EAST MAPLE ROAD SYSTEM (E>astirig Pipes S I T E PLAN EXISTING REAR DCPORCH: 156 SF GREENLAWN. NY 11140 Head Totted This Location) ! 190 SF 1" - 20'-0" EXISTING GARAGE/COTTAGE: 1141 SF WATER MLL,NYH11914 ! EXISTING COVERED: 148 SF r EXISTING SHED: 118 SF TEL 431 154-5555 / ftaeberarchitectimphoo.com TOTAL EXISTING SQUARE FOOTAGE: 3196 SF SYSTEM GRADE CONCRETE EXISTING LOT COVERAGE: 12.14 / APARTMENT CONTROLLER/ GRADE RISER TO EI +26.0' COVER SEAL. EL +21.5 ALARM EL +26.0' GRADE �A I' MIN. t 2' MAX. PROPOSED HOUSE CONCRETE a �, FIN. FL. CHIMNEY DEPTH EXISTING HOUSE: 1854 SF 1,yq d °, 11 _ PROPOSED 5ANITARY 5YSTEM EL +23_3 EXISTING FRONT PORCH: 103 5F ----""" 4"0 APPROVED CONCRETE EXISTING GARAGE/COTTAGE: 1161 SF . DOME EXISTING SHED: PUMP OUT AND ABANDON EXISTING SANITARY SYSTEM PIPE, 1/4" PER FT. 18" ANHO E 1 " MAN OLE 24" MAN OLE 118 SF ro 4"0 APPROVED ^� ? s s . . (LOCATED ON WATER SIDE OF EXISTING HOUSE) PER MIN. PITCH " — ,( " 'PIPE, 1/8" PER FT. PROPOSED REAR PORCH: 115 SF SUFFOLK COUNTY HEALTH DEPARTMENT STANDARDS •--------- I _4 " I -6 MIN. PITCH PROPOSED RAISED PATIO: 141 SF _. INV RT PROVIDE PROPOSED SCREEN PORCH: 161 SF PROVIDE AND INSTALL NEW I/A OWTS PER SCDHS STANDARDS at HOUSE CLEAN OUT I V RT I PROPOSED SPA/TERRACE: 200 SF FOR (5-L) BEDROOM HOUSE EL +21.0' • HOUSE L 20. m INVERT, I INVERT EL +20 EI +19.15' O I TOTAL PROPOSED SQUARE FOOTAGE: 3991 SF NEW "FUJI-CLEAN' CEN-1 TREATMENT TANK PROVIDING I 5'-2• m4 -Il 1 m ® 4•_11 1/2" 1 I I PROPOSED LOT COVERAGE: 13.41 _ 100 GPD HYDRAULIC FLOW (660 GPD REQUIRED) NEW 400 S.F. SIDEWALL AREA OF LEACHING POOL (1) POOL. 10' 0 x 13'-0"' DEEP) I i REV.: MARCH 12. 2021 MEET ALL S.C. DEPT. OF HEALTH SERVICES REGULATIONS. I ' NOTE: • - ••-'�- i NEW LEACHING p i DATE: FEB 2. 2021 , BED OF��•-�� w I I/A OWTS TANK GREATER THAN 15 FROM SURFACE WATER FUJI-CLEAN CEN-1 3' MIN. POOL (•400 SF I I LEACHING POOL GREATER THAN 100' FROM SURFACE WATER STONE TREATMENT TANK COLLAR SIDEWALL AREA) �' I SCALE: 1• = 20' I/A OWT5 TANK t LEACHING POOL GREATER THAN 10' FROM STRUCTURES I JOB N0: w202004 I/A OWTS TANK t LEACHING POOL GREATER THAN 5 FROM PROPERTY LINE 9'-II" 8'-O" I 10'-O' � DRAWING SCHEDULE O I DRAWING NO. I DESCRIPTION I I Al SITE PLAN I I i A2 IST FLOOR PLAN I I I I A3 2ND FLOOR PLANAl I I A4 ELEVAT16NS 3' (MIN.) TO HIGH ISEASONAL GROUNDWATER I OF A4 L-------------------------------'