HomeMy WebLinkAbout46823-Z i
SUEfe c TOWN OF SOUTHOLD
�o ay BUILDING DEPARTMENT
N TOWN CLERK'S OFFICE
"o • ���s% SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
I
Permit#: 46823 Date: 9/15/2021
Permission is hereby granted to:
Umana, Jose
51750 Route 25
Southold, NY 11971
I
To: install roof-mounted solar panels on existing accessory garage #2 as applied for per
HPC approval.
At premises located at:
51750 Route 25, Southold N O T' l NSI L L
SCTM # 473889
Sec/Block/Lot# 63.-6-4
Pursuant to application dated 5/21/2021 and approved by the Building Inspector.
To expire on 3/17/2023.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CERTIFICATE OF OCCUPANCY $50.00
Total: $200.00
i
i
Building Inspector
i
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
SOUTHOLD,N.Y.
NOTICE OF DISAPPROVAL
DATE: February 5, 2021
TO: Mary Schmeling(Umana)
265 Sunrise Highway#1-173
Rockville Centre,NY 11570
Please take notice that your application dated January 20,2021:
For permit: to install roof-mounted solar panels on(2)accessoryygarages at:
Location of property: 51750 Main Road, Southold,NY
County Tax Map No. 1000—Section 63 Block 6 Lot 4
Is returned herewith and disapproved on the following grounds:
The proposed construction is not permitted pursuant to Section 170 of the Southold Town Code
and is subject to Historic Preservation Commission approval.
Authorize ign
Note to Applicant: Any change or deviation to the above referenced application may
require further review by the Southold Town Building Department.
CC: file,Landmark
i
FIELD INSPECTION REPORT DATE COMMENTS ,
b
FOUNDATION(IST)
H
----------------------------------- �"
LA
FOUNDATION(2ND)
z t
ROUGH FRAMING.&
PLUMBING y
O
r
INSULATION PER N.Y. H
STATE ENERGY CODE
FINAL
��A�DDITI N COMMENTS
OD 19 IiV V
O
Z
' rn
O
d
b
H
i
00
FFOtO�ILDING DEPARTMENT-Electrical Inspector
�CGG � TOWN OF SOUTHOLD
3 Awn Hall Annex- 54375 Main Road - PO Box 1179
o • S�Q Southold, New York 11971-0959
!yfjol ,e (631) 765-1802 - FAX(631) 765-9502
, southoldtownny._qov - sea ndCcD-southoldtownny.gov
i
APPLICTION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (Ali information Required) Date: g- a -7-
Company Name: Lo vt- �s I ,-ek 5 a ✓ So to hw-,
Name: ...f D 1i v, Tb 2�
License No.: &/I, 3 o l- Me- email: a k, `J )w, h
Phone No: Q6- &g- gg-21, ❑I request an email copy of Certificate of Compliance
Address.: , 2 a- l ! -7 a-v
JOB SITE INFORMATION (All Information Required)
Name: J o S-e U,,,, �
Address: Vit ad- S L)k-0
Cross Street:
Phone No.: " ,, s— 6 0
Bldg.Permit#: email: J ase
Tax Map District: 1000 Section: Block: Lot:
BRIEF DESCRIPTION OF WORK (Please Print Clearly) hS�1( `D0 7L fu e
c,-
Check All That Apply:
Is job ready for inspection?: ❑YES ❑NO ❑Rough In ❑Final
Do you need a Temp Certificate?: ❑YES ❑NO Issued On
Temp Information: (AII information required)
Service SizeF_11 Ph ❑3 Ph 'Size: A #Meters Old Meter#
❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead
#Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N
Additional Information:
i
PAYMENT DUE WITH APPLICATION
i
Electrical Inspection Form 2020.xlsx
I
i
i
out Uniqt,e
l Mariella Ostroski,Chairperson Zr em Town Hall Annex
Anne Surchm,Vice Chair ; MUTHOLD 54375 Route 25
Joseph McCarthy un�uyOAK PO Box 1179
N founded +{ r o Southold,NY 11971
Fabiola Santana = u
I Allan Wexler 0� �� �� Telephone: (631)765-1802
Tracey Dwyer,Administrative Assistant
RESERVATION
southoldhpc@southoldtownny. og_v
i
Town of Southold Historic Preservation Commission
i
May 20,2021
I
RESOLUTION.#05.2 0.21.3
Certificate of Appropriateness
i
i
RE: 51750 Main Road,Southold,NY, SCTM#1000-63.-6-4
Owner: Umana,Jose
RESOLUTION:
WHEREAS, 51750 Main Road, Southold,NY is on the Town'of Southold Registry of Historic
Landmarks, and
1 WHEREAS, as set forth in Section 56-7(b)of the Town Law(Landmarks Preservation Code)
of the Town of Southold, all proposals for material change/alteration must be
reviewed and granted a Certificate of Appropriateness by the Southold Town
Historic Preservation Commission prior to the issuance of a Building Permit,
and,
WHEREAS, the applicant submitted a proposal to install roof mounted photovoltaic system
panels on(2)existing accessory garages as applied for, and,
WHEREAS, the applicant presented commissioners with an outline of the project during a pre-
submission conference on April 1.5, 2021,and,
WHEREAS, a public hearing was held on May 20,2021,where the applicant submitted final
drawings of the scope of work and outlined the project for the commission,and,
NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation
Commission determines that the proposed work detailed in the above referenced application
meets the criteria for approval under Section 170-8 (A)of the Southold Town Code and,
i
BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of
Appropriateness.
i
MOVER: Commissioner McCarthy
i
SECONDER: Commissioner Santana
i
AYES: Ostroski,Surchin,McCarthy, Santana and Wexler
RESULT:Passed
Please note that any deviation from the approved plans referenced above may require further
review from the commission.
Signed: ao
,
Tracey L.Dwyer,Application Coordina or for the Historic Preservation Commission
Date: May 21,2021
i
f
I
i
I
I
I
i
265 Sunrise Hwy
Suite 1-173
Rockville Centre, NY 11570
o516-353-5360
Cm et ng.co
Pinfo(a�completeexpeditina.com
www.completeexpediting.com
ExLedieti, ng
July 29, 2021
i
Town of Southold
Building Department
Town Hall Annex
54375 Main Road
PO Box 1179
Southold, NY 11971
Re: 51750 Main Rd Southold
Solar Panel Application—Jose Umana
Dear Building Department,
i
! We represent the homeowner for the above listed address and have submitted a permit
application for Solar Panels. On 7-19-21 we were informed that you needed updated plans
reflecting the 2020 NYS Residential Code and 2017 NEC Code. Enclosed are the revised plans
for the above listed address. Please mail the permit to us at the above address.
I
j If you have any questions o urther information is required, please contact us at 516-353-5360.
i
Thank you,
i
Mary Sc elin9
Complete Expediting
I
I
i
i
i
i
I
(516) 353-5360 info@completeexpediting.com www.completeexpediting.com
i
265 Sunrise Hwy
Suite 1-173
Rockville Centre, NY 11570
Cm o516-353-5360
et ng.co
info(c�completeexpeditinq.com
Pwww.comr)leteexpediting.com
E2i editi, ng
i
August 31, 2021
I
� Town of SoutholdM
Building Department L V
Town Hall Annex D
54375 Main Road
PO Box 1179 S E P 1 3 2021
i
Southold, NY 11971
BUILDING DEFT.
Re: 51750 Main Rd Southold T01VIN OF S(.DUTHOLD
Solar Panel Application—Jose Umana
i
Dear Building Department,
We represent the homeowner for the above listed address and have submitted a permit
application for Solar Panels. We were informed that you needed updated plans reflecting the
2020 NYS Residential Code and 2017 NEC Code along with an Electrical Application and check.
Enclosed are the revised plans, electrical application and a check for$200.00 for the above listed
address. Please mail the permit to us at the above address.
If you have any questions or further information is required, please contact us at 516-353-5360.
i
Thank you,
Mary Schm mg
Complete Expediting
{
I
i
i
i
I
i
i
(516) 353-5360 info@completeexpediting.com www.completeexpediting.com
i
N/F THE FIRST UNIVERSALIST CHURCH OF SOUTHOLD ` SOUTHOLD UNION FREE SCHOOL
cm S 74'50'00"E CHAIN LINK FENCE N/0 PROP. LINE
N9M
Ouw O ural _I rTnct same OF vsanLT+n uc ;t � � DISTRICT #5
04
aw, —39.2_A cpeTi
1 W
1.7' 20.2. gz 1220.1co
FRAME GARAGERESIDEN GARAGE
#
o
z
FRAME
a
0
20.7 N i:;,C4 w
`aLm� M GARAG t`�
o /4 t&-A T-0z W9
io sa or.pulc.T DRIVEWAY gw,
ASPHALT co 24.2' to
NZ—
Gia LN4N . N
co N 74'50�00"W STOCKADE FENCE SOUTH OF PROPERTY UN' 33U'':Ul�I I
N/F THE FIRST UNIVERSALIST CHURCH OF SOUTHOLD
0W.Y70 REFOUMMR WNOM A£SZOMY
L9LRUMREDAWONNW80L4F70TLE FORMERLY BOOTH
MLFCOIFAWY,GOWSWA CALAODWY,
LP1aw ramnag F149'7WN9O K ANDTV PEAR&WATM OF IWL&47M 0677711"M
.
6UARWMAneNOrTAV406 A9a8TO
jmj4VnjCfaMAL7m0,XN CRADDOM TO 7HLS
SWIOEYISA MAWNCFSWTXW 7"OF
AE NEW WAK SWE WLrA7M LAW. I 1 or/
ccmvor7NL mor4YLawNor sawravo S611e-;&1 SURVEYED: 21 JULY 2005
7WL4WSWV2V WfiU90S6EDSLs &WL �'(/
NorsECCNSldev7OWAMMTRI/E SCALE 1"= 40'
COPY. SURVEY OF
DESCRIBED PROPERTY AREA = 26,081 S.F.
SITUATE j OR
ossa ACRES
SOUTHOLD, TOWN OF SOUTHOLDSUFFOLK COUNTY, 'N.Y.
SURVEYED BY
SURVEYED FOR: ROMANELLI BROTHERS LLC STANLEY J. ISAKSEN, JR.
P.O. BOX 294
TM# 1000-063-06-004 NEWS FFOLK. N.Y. 11956
631-7 4-5835
GUARANTEED TO:
ROMANELLI BROTHERS LLC
PECONIC ABSTRACT, INC. _
CENS ND VEYOR
NYS Lic. No. 49 3 05R 1424
I
APPROVED.AS NOTED -�2
DATE: v. a B.P.# oV
FEE:'-
BY:
NOTIFY BUILDING DEPARTMENT
765=1802"-'8 AM TO 4 PtAl FOR THE
FOLLOWING,INSPECTIONS:
;-1. FOUNDATION - TWO REQUIRED
FOR POURED CONCRETE
2. ROUGH - FRAMING & PLUMBING
3. INSULATION
4. FINAL - CONST;UC-10N MUST
BE COMPLETE FOR'(..0.
ALL,CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
;YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
I
COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REQUIRED AND CONDITIONS OF
RS9�> 9 N ZBA
`�i rru�i n Tn�einioI ehinu yG BOARD
I
TRUSTEES
i
OCCUPANCY OR
USE IS UNLAWFUL
WITHOUT CERTIFICA�
OF OCCUPANCY
I
ELECTRICAL
INSPECTION REQUIRED
i
4
IGOROUS LOAD ANALYSIS
-0 3000E Birch Street,Suite 201 0 area,CA 92821 Ph:844-783-5483
DATE: 07-22-2021/Rev A
FOR: YourSolarPlans, Inc. JOB: Umana, Jose
3000 E. Birch St 51750 Main Road
Suite 201 Southold, NY 11971
Brea, CA 92821
USA
To Whom It May Concern
This letter is to certify that we have performed a structural analysis of the existing roof members that are to
support photovoltaic panels, as shown on the attached report. The calculations were performed in
accordance with NDS 2018, ASCE 7-16, and 2020 Residential Code of New York State.
Our analysis was based on the following design criteria:
Ground Snow (psf) 25 psf
Sloped Snow(psf), reduced per ASCE, Sect. 7.4 23.78 psf
Basic Wind Speed (mph): 135 mph
Roof Slope: 18 degrees
The PV module orientation: Portrait
The maximum horizontal roof mount spacing: 4 ft.
The maximum vertical roof mount spacing: 3.292 ft.
Staggered roof mounts required? Yes
Based on this analysis,we can certify that the individual existing roof framing members that support the
PV panels; and the individual roof members as described in the attached report; are adequate to support the
design loads as required by the various codes. This includes Dead Loads(including the weight of the PV
panels), Live Loads, Snow Loads, and Wind Loads, on the roof members that support the PV panels,
combined as required in the codes.
If you have any questions on this or need further clarification,
please contact us at your convenience.
OF NEW Y
co XP el
Sincerely, rl-
James A. Adams,
S.E.
NOTE: A FESS lo���
1. Prior to commencement of work,the Solar Installer shall verify
that the roof framing sizes, spacing, and spans (between supports),
are as noted in these plans. The Engineer of Record must be
notified if any discrepancies are discovered, before proceeding.
2. These plans are Stamped for Structural Code compliance of
the roof members that support the PV solar system only.
3. These plans are not stamped for rain water leakage prevention.
4. As a precaution, old or wet snow should be removed from the roof,
if the snow builds up to 18" or more.
i
Date of Report: 07-22-2021/Rev A Job Name: Umana, Jose
I Data Input by: Kevin Nguyen Job Number: UMANA
Contact E-mail: kevin@yoursolarplans.com Job Address: 51750 Main Road
Contact Phone: 7148721728 Southold, NY 11971
I
ABSTRACT Job Information
This Report is based on Engineering calculations Data Input By: Kevin Nguyen
using the input data supplied by the user, listed Job Number: UMANA
under Current Input Data.The user input has not Job Name: Umana, Jose
been independently reviewed by a licensed Job Address: 51750 Main Road
Professional Engineer for appropriateness or City, State: Southold, NY 11971
accuracy, unless Stamped by a P.E. This Report
indicates Compliance/Non-Compliance with the Current Input Data
reference Codes listed below. The following items
have been checked for Code Compliance: Payment Method Invoice
Roof Type Sing leSpanRafters
-;Load Combination#1: Ceiling Type 1/2 gyp. Bd.
Wind Uplift on the Standoff attachment to Collar Tie Space 0
the Roof Framing members: Wind Uplift- Coverage% 33.6
0.6* DL Solar Frame Size 2x6@16
Ground Snow(psf) 25
-i Load Combination #2: Sloped Roof Snow Load (psf) 23.78
Supporting Rafter Strength with: DL Rf+ Lag Screw Diam. (in) 5/16
DL Solar+ Roof Live Load Lag Screw Embed. (in) 2.5
Overall Span (ft) 34
-Load Combination#3: PV Weight(psf) 3
Supporting Rafter Strength with: DL Rf+ PV Module Orientation Portrait
DL Solar+Wind Down Rafter Span (ft) 14
Rail System 2Rail
Load Combination#4: Supporting Rafter Roof Mean Height (ft) 15
Strength with: DL Rf+ DL Solar+ Snow Roof Slope (degrees) 18
' Roofing Type Comp. Shingle
Load Combination#5: Sloped Ceiling No
Supporting Rafter Strength with: DL Rf+ Max. Horizontal Roof Mount(ft) 4
DL Solar+ .75Wind + .75Snow Max. Vertical Roof Mounts (ft) 3.292
Standoff Staggered Yes
Load Combination#6: Check Additional Wind Exposure C
Seismic Load Wind Speed (mph) 135
=Load Combination #7:
Supporting Rafter Strength with:
Wind Up-0.6 *(DL Rf+ DL Solar)
I
i
I
STRUCTURAL CALCULATIONS FOR PV INSTALLAMN
y Prepared for
SOLAR= 8 09' F= CNEC
YourSolarPlans, Inc.
3000 E. Birch St, Suite 201
Brea CA, 92821
r USA
818-939-8098
USER: Kevin Nguyen
� F
COMPANY NAME: YourSolarPlans, Inc.
SRC JOB ID: 28865
-------------
I'll, JOB REPORT DATE: 2021-07-22/Rev A
t JOB NUMBER: UMANA
�s
JOB NAME:- � Umana, Jose
� = JOB ADDRESS: 51750 Main Road
Southold, NY 11971
A.
N
I AFESSIONP
I
i
i
I
Program Version: 2020-05-08:7
I
844-783-5483
Contact: Support@Saler-Roof-Check.com Phone.
i
I
i
i
Page 2 of 10
I
USER INPUT:
1. .Ceiling Type := 1/2 gyp. Bd.
2. -Collar Tie Spacing (ft) :=-0
i
3. Roof Coverage % := 33.6 .
4. Roof Framing Size ;= 2x6@16
5. .Ground Snow "(psf) := 25
'6. Vertical Snow Load on slope (psf) ;= 23.8
'7. Lag Screw Diameter (in) A := 5/16
8. Lag Screw Embedmen:t'(in) 2.5
9. .Overall Span (ft) :_ 34
I
10. PV Weight.(psf) DLpv = 3.00
11. Rafter Sloped Span ;(ft) Lr := 14
12. Rail System 2Rail
13. Roofing Type := Comp. Shingle
14. Roof Mean Height (ft) = h 15
`15. Roof Slope (degrees) ._ := 18
i
16. Roof Structure Type SingleSpan Rafters
17. Sloped Ceiling? := No
:18. Sfh = RF Mount Horizontal Spacing (ft) 4.00
,
19. Sfv = RF Mount Vertical Spacing (ft) 3.29
I
26. RF Mount. Staggered Yes
21. "Wind Exposure := C
22. Wind Speed (mph) .= V := 135
23. Lpv=PV'Length (in) 79
24: 'Wpv = PV Width (in) 39
25-Gable, Hip, or Flat/Monoslope Gable Roof
j 26. Roof Overhangs Yes
27. Sr= Rafter:Spacing (ft) 1.33
28. PV Orientation Portrait
29. Elevation Above Sea Level (ft) .= Elev := 25
Page 3 of 10
FORMULA SYMBOLS:
TAfp := Tributary Area to. RF Mounts with Portrait PV Dri.entation (sf)
TAO Tributary Area to RF Mounts .with Landscape P.V .Orientation (s f)
-T r Tributary Area to Rafters sf)
Ia-f Pressure-Equalization Factor for.RF_Mounts,_with Portrait PV:Or.ien,tation
_
af Pressure Eq`ualizatlon Factor for RF Mounts "With Landsca iie PV Orientation
'Y�r Pressure"Eq' Factorfor-Rafters
Pifp Design Wind Pressure'to RF Mounts:Wit[! Portrait PV-.Orientation - Zone 1 (ps .
P2fp Design Wind Pressure to.RF Mounts;;with"Portrait PV orientation - Zone '2 {psf)
,.PM Design Wind Pressureto RF Mounts:with Landscape .P,V:Drientation Zone':1. psf}
1?2fi benign Wind 'Pressure to',RF.MountS with La-ndscane PV Orientation -:;Zone 2 sf)
.Pr,lp Design Wind:Pressure`Un to ,Rafters (psf)
Prdii Design Wind Pressure"Down to Rafters -(psf)
,GCP1. := External Pressure Coefficient fo,r RF Mounts .Zone 1 (depends.-on TA Fastener)
GCp2 External Pressure Coefficient for RF Mounts - Zone'2 (depends-:on TA Fastener)
GCpup` := External.Pressure Coefficient; Wind Ub`for Rafters ;(depends on TAr)
i
GCpdn := External Pressure.Coefficient,-�Wind Down :for-Rafters_(depends on TAr)
S Snow-on-Roof.(psf)
sm , _. RF Mount Horizontal Spacing (ft)
i
sfvRF Mount Vertical Spacing-(ft}
Asr Rafter Spacing (ft)
Lpv; PV'Length (ft)
i
PV Width (ft)
,Lr Span of Rafter (ft)
'YES Edge Array Factor
Page 4 of 10
Dead L6ads'(DL): psf
Roofing = 2.20
1.50
Rafter- = 1.50
Miscellaneous (Misc), 1.00
CIO. joists = 0.65
InsUlation (Insul) 0.50
Ceiling 2.20
Flat Ceiling DLtc'--':'R6ofihg Ply + 110ter + Mist (OS*f): 6.20
DUc + nsu + Ceiling 's P�-T) 3.35
b
wbLtc QLtex_Sr P 0 8.27
Sloped Itellifig' L COC=DL.t6N/A
+jhkil. + Celling (Po),
wQLtc,"—DLt6,x*.Sr �P,19 N/A
DESIGN CkTERIAASCE
REFERENCE
Risk Category II '.Table".L5-1,
Importance Factor Table 1.572' 1.00
Basic Wind Speed flg.-26,5-1b- v = 135
Wind Difectional Ity Table 26,'6-4- Kd 0.85
Exposure Category: ,Sect. 26.7.3�-
C
I .
TopographicFattor Sect. 26.'8 Kzt = 1.00
Elevcitiofi- aboVe"Seh16V-61 Table"26,9-1 Re: 1.00
Velocity Pressure Exposure Table'26,1071 K-. 0.85
Veld .
Velocity Pressure -EO -26.10-1 qh Z . 2 33.68
,y =.00256 x K -x ,Kzt x Kd X Ke-X V
Edge Array Facbar. Sect, 29,4 1.4 IE (Zone 1) =1.0 -YE(Zone2) 1.5
PV Pressure Equalization FI 29.4-8
la 0.71
Factor
Page 5 of 1:0'
,RF'MOUNT- Wind OP Pressure (Note: 'Divi.de TA by 2 for 2 Rail System)-
Portrait Orientation:
ASCE REFERENCE TA I = Sfh k Lpv
13.17
Fig. 29.4-8 1 I'a 0.71
Fig'. 30.3 Zohe-':L: GCpi 2.00
Eq. 29.4-7 PIf = qh x'G*QpI k-iEx^fA = 48.13
Fig. 30:3-2* Zd'h'e 26- GCp 2e 2.50
-
Eq. 29.4-7 -P2 e f-,-- clh.x GCp'2.x IE'x 7a90.25
Fig. 3,0.3-2 Zdile'2r: GCp2r 2.83
.
E0.29. -7 P2rf =qh x GCp2r X'YE X 'Ya 102.13
karidscane Orientation:
-ASCE REFERENCE 'TAfi = Sfh-x. --Wpv N/A
Fig. 29.4-8 !a N/A
Fig. 30.-3':2-* Zone 1:' .'GCpi NIA
PIf qh x GCpj >�-it x-in
Eq.2§.477' N/A
Fig. 3,0'3-2* Zdn- -e; .26: GC N/A
p2e
Eq.29.4-7 P2ef = qhx GCp2e x^(E x"Ya
N/A
Fig., 30.3-2* Zone 2r: GQ p2r N/A
Eq.. P2rf =q}1 x GCp2r x IE x^in, N/A
*NOTE:For Flat and Monoslope Roofs, refer to Figures 30.3-5A and 30.3-513
Pagq 6 o 10
RAFTERS-Mind UP Pressure
ASCE REFERENCE TAr = 8fh N-4 56.00
ar
Fig.;29.4.-8 29.4_8 0.46
M Zone' 1�. G-COUP, 1.04
. !g. 3.0..13-2
Eq. 29.4-7' -Prup ch x GCpjjp X-MX.Aja 16.03
!Z,AFTERS-Wind DOWN Pressure
'ASCE REFERENCE TAr= :Sfh x Lr = 56.00
Fig..-
,29. 4-8 0.46
Fig. 50. 3.2* Zone 1: :GCpdp = 0.36
'Ply 'x GCp- 16.00
-Eq. 29.4-77 qh dn x, YE )� la
LOAD:COMB. ,#'1: WIND UPLIFT ON
N RF MOUNTS .(O.6DL - 0.6 .Wind.'Up) jiCd =.1.6)
t.=--Withdrawal Capacity (lb/inch) t = 235.00
W= Total Withdrawal Capacity940.00
W Cd,�<t.k 0 :W
TAf>((0.6 x'Plf-'0 ->VDLPV x cos(O x d6o) 357.72
% =W x I OOIPf 262.8%
torn' liant if % is equal.to ' r-more than 100%
-.Code, . ..p o mo
ZONE 2e' 'P TAf N
.. . (0.6-x P2ef- 0.6 x nLpV.x ep.s(O x deg690.46))
% = W X 1001P20 = 136.1%
-Code Compliant if % is equal to-or more than, 100%
z6NE 2t P TAf x (0.6 k P2rf `0.6 k DLj?V x 66s(' x de 784.30
0 M
% W 1001P2rf. = 119.8%
-Code Compliant if % is equal to or more than 100%
:Page 7 of 10
i
LOAD COMB.:#2:' 0n RaftersDL RF+ DL SoLA'R+ RF LL(CD=1.25) with LL = 20 psf
i
W:='LL x Sr p1f (plf) = 26.67 Psp -=TAfX DLpv = 39.50
� I
4.25 M s-- WL L- x ��. +P x L' x COS 9 398.87
Z (. ..). DL tc. sp {
i L .
" w x is cos.{8}
Spans C':10.0 ft N/A
._ 2 xL
mLL•_
I Vil
Z,X`W
fi {wx`cx(2xL=c}-1-wxc?}}
8p'aris :; 10.'0 ft t .- 2 x L 4 229.05
MLL'=
2x
12
627.92 -ter2 .= 2.02
:AbxCd, CLs
*.—x 1Q0 CC:;Ifequal to or 'more than;100% 'Code :Compliant,.OK! = 375.0%
LOAD COMB. #3: On Rafters, Zone'1 DL Rf + D.L�Solar -+:,W,ind Down (Cd '=1:G)
P3=TAx(0.6 x Prd,+.D3LpV-x.COS' := 163.97
M3 - WDLt�x $ x COS(!9 x d@g)-{-_P�X_
=1092.83
Sr: �)
l Max 12 =
FbxCdwiridxCfXxC,.xC« 2.74
Sxx100
C,C If equal to or more-than"104% Code;Compliant, 0 K! := 275.8%
i
I
i
I
i
i
Page 8 of 10
LOAD COMB. #4: On Rafters DL Rf + DL Solar-+ Snow (Cd=1.15)
S:=Sloped Roof Snow Load (psf) = 23.78
P4:=TAfx(DL x S) 352.60
z
M4 =(WDL,x 8 +P4 x a x COS�8} =2033.73
SI '12'=M4 X 7.10
FbxCdSnowxCf,xCrxCLS
i SX x 100
Flo:= S <<If equal to or more than -100% code Compliant, ok! 106.5%
r
LOAD COMB. #5: On Rafters, Zone 1 DL Rf + DL Solar + .7SWind + :75Snow (Cd=1.6)
S:=Sloped Roof Snow Load (psf) 23.78
.P5;=TA fx (DLpy=I-.75 x S) x Cosa-i-TAx 0.75 x O.0 x prdn 355.70
M S;= WDLtc X L 8 Z +PS x L x cos(8) =2145.49
a
S r4x
12
r ' s FhXCdWindXCfxXCrXCLS
= 5.38
-SX X100
S «If equal to or more than 100% Code .Compliant, OK! 140.5%
Sr
LOADING COMB. #6: CHECK SEISMIC LOADING: .0=COVE RAGE ON ROOF
I
Existing DL:= DLRf + Walls Walls:= 5.5 psf 15.05
ProposedDL:=ExistingDL + .DLsolar x,C = 16.06
ProposedDL <<If equal to or more than 10% Code
SeismicIncrease:=100 x /—100 = 6.7%FxistingDL J Compliant, OK!
SEISMIC SUMMARY: EXISTING BUILDING P.ROVISI,ONS
Section 116.3- Exceptions:
1. The addition complies with the requirements for new structures:
2. The addition does not increase the seismic force by more than 10%.
.3. The addition does not decrease the seismic resistance of any-structural element.
i
i
Page 9 of 10
'LOAD ZOM0. #7: On Rafters, ZONE .1 (0.6)(DL RF + DL SOLAR) - WIND -UP (CD=1.6)
P?:= TAf x (0.6 x PP-0.6 x DL.pv x Cos$) 104.13
z
M,:= P.�x L —wDLr�x L x cos(9 x deg) := 456.13
I a 8
12
iS
•=M X -
r• 7 Fb x Qd wi,,d X Cfx x Cr X Cis .— 1.14
sXx 100 IF EQUAL TO OR MORE THAN 10 %0CODE
°fa « = 660.8%
Sr COMPLIANTS.OK!
LIMITS .OF SCOPE OF WORK AND LIABILITY
Note:
1. Prior to commencement of work, the Solar Installer shall verify that the roof
framing sizes, spacing, and spans,(between supports),,are as noted in these
documents. The Engin--'e Record must be notified if any discrepancies are
discovered, before proceeding.
2. These documents are.Stam_ ped for Structural Code compliance of the roof
members that su-pport the'PV solar system .only.
:3. These documents are'hotstamped for rain water leakage prevention.
4. Asa precaution, old or wet snow should be removed from the roof, if the.snow
builds up to iV or more.
5. Existing- deficiencies"which are unknown and not observable due to their being
concealed inside walls or-sandwiched behind gypsum board ceilings at the time
i lof inspection are not included in the scope of work. These calculations are only
for the roof framing which .'supports the new PV modules. These calculations do
not include a complete lateral analysis of the building, nor a prediction of the
i
life expectancy.of the, existing building.
i
i
.i
a
Page 10 of 10
l R
Appendix
'I Table 3 represents the maximum Moment (M = PL/a) resulting
from point loads (RF Mounts), for any spans (L) listed.
a = 2.55
€ABL.E 3
The Moment Factor"a"fora 2 Rai[System The Moment Factor"a"for a Rail[ess or Shared Rail System
Staggered Unstaggered Staggered Unstaggered
Length Portrait Landscape Portrait Landscape Length Portrait Landscape Portrait Landscape
` _._ _ 4 Q 4 00 2 31y L ' S 00 00 z Qd 5 00
L;=S' x.00 3.50 3.72 2.50 _L=5'
_5' 5.00 5.00 5.00 5.00
L;=7' 3;60 '2.84 a 2.95- 1.83 L=7' 4.50 4.50 4.50 4.19
4
L=9' 3.03 2.59 2.34 3.44 L=9' 4.00 4.00 4.00 3.12
L=1Y' 2.77 2,25 -2.04 1.19 L=11' 4,00 4,00 3.70 2.48
4 aoo � .o
L A 13' 7; � 2.61 1.88 � 1.74 _ 0.90 _ _�.
'rtr AAA 1 iL 1(T _ 4.00 3.0 3.95
_ 3.9t�+8rf
__..�4# i
L=IV 2451 1.68 1.50 0.86 L=15' 4./003:3_2y� 2.88 y1.78�
L='17' 243 1.45 1.31 _0.76 L=,17' 4.00 2.74 2.36 1.57
L=19' 2..38 1.24 1.17 0.68 L=19' _ ~✓ 4.00 2.46 2.18 1.38
11.-'C67" $Z11'T 065 .
L=21' 2.22 1.14 1.06 0.62 L=21' 4.00 2,28 2.06 3..25
REFERENCES: LATEST EDITION
Duration Factors Section Modules Size Form Factor
Cdwind = 1.6 Sx 7.56 S2x12 := 31.640 Cf2x2 := 1.5 Cf4x4 := 1.5
Cdsnow:= 1.15 S2x2 := 0.563 S4x4 := 7,150 Cf2x4 := 1.5 Cf4x6 := 1.3
Cd DL := 0.9 S2x4 = 3.063 S4x6 := 17.650 Cf2x6 := 1.3 Cf4x8 := 1.3
ULL .= 1.25 S2z6 := 7.563 S4x8 := 30.660 Cf2x8 := 1.2 -Cf4xio := 1.2
CLS .= 2.00 S2x8 := 13.140 S4x10 := 49.900 Cf2xio:= 1.1 Cf4x12 := 1.1
Fb = 1000 52x10 := 21.390 S4x12 := 73.800 Cf2x12:= 1.0
v N
RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEM
51750 MAIN RD , SOUTHOLD, NY 11971 , USA SURF CLEAN
ENERGY
42 MODULES-ROOF MOUNTED - 16.60 kW DC, 12. 16 kW AC SURF CLEAN ENERGY
111 SMITHTOWN BYPASS
SUITE#207,HAUPPAUGE,
SHEET INDEXNY 11788,USA
PHONE NO.:(866)631-7873
PV-1 COVER PAGE PROJECT NAME&ADDRESS
PV-2 GENERAL NOTES - s
PV-3 PLOT PLAN _ — --- - —
PV-4 ROOF PLAN & MODULES Wv PV-5 ATTACHMENT DETAIL
PV-6 ELECTRICAL LINE DIAGRAM ��
PV-7 WIRING CALCULATIONS
PV-8 PLACARDS17_ Z
PV-9+ EQUIPMENT SPECIFICATIONS Pv
sw
Q r
5 _
f t �" `� �' ea ,r.:A,,� .°
if
r.. � r y
'n
4 ";- , 21" -
[ 1 '
' "d-
25
0
g , k,
rr' � .
y a -� i > -a, ax
-
IN N11
£ v r< _ 4
s
r ,<.
SHEET NAME
t
e
= OVER PAGE
�s
SHEET NUMBER
_+ x
4
y
> e
Signature with Seal
r
a
r Test
a
D
s f - r alpind 2 HOUSE PHOTO
r,= �s ` ' Pv-1 SCALE: NTS SEP 3 202
r
GOVERNING CODES
Shelter
j �� 5 50 Matn Road BUILDING DEFT
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES G� OF SGi1TiOLD
Panic EQUIPMENT SUMMARY
1. 2020 RESIDENTIAL CODE OF NEW YORK STATE
2. 2020 BUILDING CODE OF NEW YORK STATE
" e L
42 HANWHA SOLAR Q.PEAK DUO L-G7.2 400 (400W) MODULES 3. 2020 PLUMBING CODE OF NEW YORK STATE
4. 2020 MECHANICAL CODE OF NEW YORK STATE
; g 42 ENPHASE : IQ7PLUS-72-2-US (240V) INVERTERS.
id 01 ENPHASE IQ COMBINER 5. 2020 FUEL GAS CODE OF NEW YORK STATE
= zs �`
01 AC DISCONNECT 6. 2020 FIRE CODE OF NEW YORK STATE
cutch`ague � ". 7. 2020 PROPERTY MAINTENANCE CODE OF NEW YORK STATE
8. 2020 EXISTING BUILDING CODE OF NEW YORK STATE
1 VICINITY MAP 9. NEC 2017 NYS UNIFORM CODE SUPPLEMENT
10. ANY OTHER LOCAL AMENDMENTS
Pv-1 SCALE: NTS
GFNERA - NOTES
THE INSTALLATION OF PV SYSTEM SHALL BE IN ACCORDANCE WITH THE MOST • WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY
RECENT NATIONAL ELECTRIC AND BUILDING CODES AND STANDARDS, AS INTERCONNECTION, THE BREAKERNSHALL BE INSTALLED AT THE SURF CLEAN
AMENDED BY JURISDICTION OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. ENERGY
• PV SYSTEMS SHALL BE PERMITTED TO SUPPLY A BUILDING OR OTHER 0 WHERE GROUND-FAULT PROTECTION IS USED, THE OUTPUT OF AN
STRUCTURE IN ADDITION TO ANY OTHER ELECTRICAL SUPPLY SYSTEM(S) [NEC INTERACTIVE SYSTEM SHALL BE CONNECTED TO THE SUPPLY SIDE OF SURF CLEAN ENERGY
111 SMITHTOWN BYPASS
690.4(A)] THE GROUND FAULT PROTECTION [NEC 705.32] SUITE#207,HAUPPAUGE,
• THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND • ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NY 11788,USA
INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, PHONE NO.:(866)631-7873
[NEC 690.4(C)] ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PROJECT NAME&ADDRESS
— • EXISTING-PLUMBING VENTS, SKYLIGHTS, EXHAUST-OUTLETS,-VENTILATIONS PLAQUE. PLAQUE SHALL--BE UV RES ISTANT-IF=EXPOSED-TO-SUNLIG HT.-- U)j
INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC 0 ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS
SYSTEM. SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY
• INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT. Q ti
PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND • CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS Z 0-)
CHARGE CONTROLLERS INTENDED FOR USE IN PV SYSTEMS SHALL BE LISTED THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS, < z
OR FIELD LABELED FOR THE PV APPLICATION [NEC 690.4 (B)] NOMINAL, MAXIMUM SYSTEM VOLTAGE FOR DC CIRCUITS, OR 30 VOLTS Q }.
• ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), FOR AC CIRCUITS, SHALL REQUIRE TOOL TO OPEN AND MARKED "DO 2 Z
INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT Wo �
• ALL EQUIPMENT.SHALL BE PROPERLY GROUNDED AND BONDED IN INTERRUPTING". [NEC 690.33(C) & (E)(2)]
ACCORDANCE WITH NEC ARTICLE 250. • FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH i` O
• SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41 TERMINALS, LUGS, DEVICES, OR CONNECTORS IN ACCORDANCE WITH _
• FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN NEC 110.14 Lo
6AWG SHALL COMPLY WITH NEC 250.120(C) [NEC 690.46] • WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE
• PV SOURCE CIRCUIT, PV OUTPUT CIRCUIT, INVERTER OUTPUT CIRCUIT, AND MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). O 0
STORAGE BATTERY CIRCUIT CONDUCTORS AND EQUIPMENT SHALL BE • ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT
PROTECTED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 240 [NEC AND APPROVED FOR USE IN WET LOCATIONS PER NEC 314.15. SHEET NAME
690.9(A)] • ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE GENERAL NOTES
• OVERCURRENT DEVICES RATINGS SHALL BE NOT LESS THAN 125 PERCENT OF TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 SHEET NUMBER
THE MAXIMUM CURRENTS CALCULATED IN 690.8(A). [NEC 690.9(B)] • EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION PV-2
• PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES,
SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE Signature with Seal
• PV DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS
LOCATION EITHER ON THE OUTSIDE OF A BUILDING OR STRUCTURE OR INSIDE ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S
NEAREST THE POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS [NEC RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING
690.13(A)] ELECTRODE.
• ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 0 DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED,
• CONNECTORS SHALL REQUIRE A TOOL TO OPEN AND BE MARKED "DO NOT "CAUTION DC CIRCUIT" OR EQUIV. EVERY 5 FT.
DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [NEC 0 CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO
690.33(E)(2)] CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER
• ALL GROUNDED CONDUCTORS SHALL BE PROPERLY COLOR IDENTIFIED AS VOLTAGE OPERATIONAL RANGE.
WHITE. [NEC 200.61 • SERVING UTILITY TO BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM.
• THE OUTPUT OF AN INTERCONNECTED ELECTRIC POWER SOURCE SHALL BE 0 ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS
CONNECTED AS SPECIFIED IN NEC 705.12(A), (B), (C), OR (D). AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.
• THE HOMEOWNER IS RESPONSIBLE FOR ENSURING ALL EQUIPMENT
OUTSIDE THE SCOPE OFWORK IS NEC COMPLIANT.
MODULE TYPE, DIMENSIONS & WEIGHT N
NUM'BER OF PANELS IN ARRAY=42 MODULES
MODULE TYPE= HANWHA SOLAR Q.PEAK DUO L-G7.2 400 (400W)
MODULES
MODULE WEIGHT= 51.80 LBS/23.5 KG. .SURF CLEAN_
MODULE DIMENSIONS = 79.33"X 39.37 21.69 SF ENERGY
UNIT WEIGHT OF ARRAY = 2238.60/903.00 =2.48 PSF
SURF CLEAN ENERGY
111 SMITHTOWN BYPASS
SUITE#207,HAUPPAUGE,
NY 11788;USA
PHONE NO.:(866)631-7873
PROJECT NAME&ADDRESS
(E)200A MAIN SERVICE PANEL TIED Z
TO EXTERIOR UTILITY METER (E) FENCE C z_
(42) ENPHASE: IQ7PLUS-72-2-US G
330'-0" (240V) INVERTER Q �'
— — � z
— — _ — — PROPERTY LINE ui
[] I 0 ti O
1-STORY - -- -- - - = _I L _
of �
,- -- -, e rQ I I � F-
z io s a to O I I „e C
Q m I = I I -f}•- Z O
N
m
ROOF ACCESS POINT
co I j
x ` G I o
f � b SHEET NAME
-ou /—— o PLOT PLAN
-I
m I —— �J
-I EXISTING
-C SHEET NUMBER
Z DRIVEWAY r I PV-3
m - --- - --- --- - -- - - - - -- - - -- - - -- - - - - -- - - - -- - - - - - - -
_ Signature with Seal
PROPERTY
339'-3" — — --- —
R F#1 R F#2 I
(20) HANWHA SOLAR Q.PEAK DUO (22) HANWHA SOLAR Q.PEAK DUO
L-G7.2 400 L-G7.2 400
SLOPE:18° SLOPE:18°
AZIM.: 182° AZIM.:268°
NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY
-SCALE AS SHOWN - INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME:
1 PLOT PLAN -ALL DIMENSIONS IN FEET - INSTALLERS SHALL UPDATE NAME, ADDRESS, AND PHONE NUMBER OF ADDRESS:
PV-3 SCALE: 1/32"=1 UNLESS OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK PHONE NUMBER:
N
BILL OF MATERIALS ROOF DESCRIPTION
EQUIPMENT QTY DESCRIPTION ROOF TYPE COMP SHINGLE
SOLAR PV 42 HANWHA SOLAR Q.PEAK DUO L-G7.2 400(4'0OW) ROOF MODULE AZIMUTH RAFTERS RAFTERS
MODULE MODULE TILT SIZE SPACING SURF CLEAN
INVERTER 42 ENPHASE: IQ7PLUS-72-2-US(240V)INVERTERS. #1 18° 182° 2`'x6" 16"o.c. EN E R G Y
#2 18° 268° 2"x6" 16"O.C.
IQ COMBINER BOX 1 125A ENPHASE IQ COMBINER+WITH BUILT IN RGM,
NEMA 3R SURF CLEAN ENERGY
FUSED AC LOCKABLE MAIN SERVICE DISCONNECT(FUSED) 111 SMITHTOWN BYPASS
DISCONNECT 1 240/120 V 10,3W 60A S NEMA 3R SUITE#207,HAUPPAUGE,
ATTACHMENT 78 IRONRIDGE L-FOOT ATTACHMENTS NY .:(8,USA
PHONE NO.:(866)631-7873
RAILS 4 IRONRIDGE XR100 RAILS 132"
PROJECT NAME&ADDRESS
RAILS 18 IRONRIDGE XR100 RAILS 168"
M SPLUCE 16--SPLICE-KIT ---`— --- -- - --- ----- --- --- Q
MID CLAMPS 76 MID CLAMPS
END CLAMPS 1 16 JEND CLAMPS/STOPPER SLEEVE
GROUNDING LUG 1 4 1GROUNDING LUG
a o �
zFTI
� rn
ROOF#1 CQC z
(E)200A MAIN SERVICE PANEL (20) HANWHA SOLAR Q.PEAK DUO G Q >..
TIED TO EXTERIOR UTILITY METER L-G7.2 400 C z
/70
(E) UTILITY METER SLOPE:18 W G
z
AZIM.: 182° (42) ENPHASE: IQ7PLUS-72-2-US (n C Q(N) FUSED AC DISCONNECT (N)JUNCTION BOX
(240V) INVERTER Fn
1" EMT CONDUIT RUN IN ATTIC (N) 1-9/4"PVC UNDER GROUND % � 0
o (N) IQ COMBINER BOX CONDUIT 40'(TRENCHED) D L
z n �
SYSTEM LEGENDO
rnITcn
❑ 200A MAIN SERVICE PANEL&POINT OF
INTERCONNECTION.TIED TO EXTERIOR SHEET NAME
ROOF ACCESS POINT ' ' L
UTILITY METER b i. f ROOF PLAN &
NEW PHOTOVOLTAIC UTILITY DISCONNEC
SWITCH.LOCATED WITHIN 10'OF MSP. rn (N) 1-1/4"PVC UNDER GROUND § MODULE
z CONDUIT 120'(TRENCHED) (N)78-IRONRIDGE L- FOOT (N) IRONRIDGE XR100 - r= I-TI SHEET NUMBER
LCD NEW DEDICATED PV SYSTEM COMBINER ATTACHMENTS @ 48"OC RACKING SYSTEM V `,
PANEL. rn - y= P V-`t
42 NEW HANWHA SOLAR Q.PEAK DUO T4
L-G7.2 400 MODULES WITH NEW 42- ; T �--n Signature with Seal
ENPHASE IQ7PLUS-72-2-US INVERTERS, z
MOUNTED ON THE BACK OF EACH ^
MODULES. l J
® =FIRE PATHWAY FnROOF#2
CIO =ROOF OBSTRUCTIONS iF NEw yO (22) HANWHA SOLAR Q.PEAK DUO
L-G7.2 400
® =ATTACHMENT POINTS A SLOPE:18°
- - =RAFTER * , AZIM.:268°
=RACKING SYSTEM II
n
=EXTERIOR RUN F \
- - =ATTIC RUN O/" ESS lOw`e��
NOTES: ARRAY DETAILS: PANEL TYPE: HANWHA SOLAR
-SOLAR PANEL LAYOUT SUBJECT TO CHANGE TOTAL ROOF SURFACE AREA: 2709.33 SQFT. Q.PEAK DUO L-G7.2 400
1 ROOF PLAN & MODULES ACCORDING TO EXISTING CONDITIONS TOTAL PV ARRAY AREA: 910.56 SQ FT. PANEL SIZE: 79.33"X 39.37"
PV-4 -SCALE AS SHOWN PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY NUMBER OF PANELS: 42
SCALE: 1/32",=1' -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED AREA/TOTAL ROOF SURFACE AREA) - 100= 33.60% SYSTEM SIZE: 16.800 kW
PV MODULE
:SURF CLEAN
ENERGY
SURF CLEAN ENERGY
BYPASS
SEE (2/PV-5) FOR 'SUITE 207,OHAU PAUGE,
ENLARGED VIEW OG NY 11788,USA
PHONE NO. (86)631-7873
O \,126 (E) SINGLE LAYER OF PROJECT NAME&ADDRESS
F NE(ij�yo @�
A. q� 'P,�- - -- - - ---- - s -- - - - - COMPO_S_ITE SH-INGLE Q
* * U)
4RA -A
FA
ZQ FSS101ft Z �
Z
W
1 ATTACHMENT DETAIL O LLo
PV-5 O
L
PV MODULES O
U)
IRONRIDGE INTEGRATED SHEET NAME
GROUNDING & END/MID CLAMP
SHEET NUMBER
`i IRONRIDGE XR100 RAIL - PV-5
Signature with Seal
(E) SINGLE LAYER OF
COMPOSITE SHINGLE
2"x6" RAFTERS @ 16" OC
5/16"X3" SS LAG BOLT WITH
MIN 2%2" THREAD EMBEDMENT,
ALUMN. "L" BRACKET SEALED PENETRATION
W/3/8" SS BOLT & NUT
IRONRIDGE L- FOOT DETAIL
2 ATTACHMENT DETAIL (ENLARGED VIE1n r
PV-5
(42) HANWHA SOLAR Q.PEAK DUO L-G7.2 400(400W) MODULES
(2) STRI'NG8 OF 1Q MODULES CONNECTED IN SERIES STRING&
(2) STRINGS OF 11 MODULES CONNECTED IN SERIES STRING.
SURF CLEAN
ENERGY
SURF CLEAN ENERGY
I 11 BYPASS
ENPHASE Q CABLE WITH SUITE#207,OHAUPPA GE,
#6AWG EGC NY 11788,USA
PHONE NO.:(866)631-7873
PROJECT NAME&ADDRESS
-I----- - CIRCUIT#1 ------ --I - -- - -- ----- - - - - --- - U)
1 2 0 0 0 9 10 I n
r ---------- TO UTILITY GRID C Z
- - - BI-DIRECTIONAL UTILITY D Q z
1 2
CIRCUIT RCUIT#2 9 10 I M METER 1-PHASE,3-W U-1
� Z
(4)#10 AWG THWN-2+RED 120V/240V U O Q
(4)#10 AWG THWN-2-BLACKLo
(1)#10 AWG THHN GND LINE SIDE TAP 0 J
ti
3/4"EMT CONDUIT Lo _
(N) 125A ENPHASE IQ (E) MAIN SERVICE �--
COMBINER+ PANEL,200A RATED,240 �
--r - -U-- - - - - - - -- -� WITH BUILT IN RGM, NEMA 3R O
CIRCUIT#3 JUNCTION BOX ^ (E) MAIN BREAKER TO (n
1 2 0 0 0 10 11 600 V, NEMA 3 HOUSE 240 V,200A/2P
UL LISTED (N) LOCKABLE MAIN ^ SHEET NAME.
10A SERVICE (TOP FED) ELECTRICAL LINE
- - - - - - - - 20A DISCONNECT(FUSED) ^ DIAGRAM
240/120 V 10, 3W
20A 100A S NEMA 3R ^ SHEET NUMBER
---------- ��
_ _ _ _ _ 20A 70A ^ PV-6
-` - ��- 0 f°— D Signature with Seal
20A - - - - - - - - - -c�
1 2 C 0RC 0 IT 0 10 11
- 0 0-
- ENPHASE ENVO
- - - -- - - -I (3)#4 AWG THWN-2 GEC
(1)#8 AWG THHN GROUND
3/4"EMT CONDUIT GROUNDING
1-1/4"PVC UNDER GROUND ELECTRODE SYSTEM
CONDUIT-120'(TRENCHED)
1-1/4"PVC UNDER GROUND
42-ENPHASE: IQ7PLUS-72-2-US CONDUIT-40' (TRENCHED)
SERVICE INFO
UTILITY PROVIDER: N/A
MAIN SERVICE VOLTAGE:240V
q MAIN SERVICE PANEL: 200A
ELECTRICAL LINE DIAGRAM MAIN CIRCUIT BREAKER RATING: 200A
MAIN SERVICE LOCATION: NORTH
PV-6 SCALE: NTS SERVICE FEED SOURCE: OVERHEAD
AC CONDUCTOR AMPACITY CALCULATIONS: SOLAR MODULE SPECIFICATIONS
FROM ROOFTOP JUNCTION BOX TO LOAD CENTER MANUFACTURER/MODEL# PEAK DUO
LHANWHNWH 400A SOLAR AR Q.Q. MODULES .
AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT SURF CLEAN
PER NEC 310.15(B)(2)(c): + 22° VMP 41.23
EXPECTED WIRE TEMP (°C): 31' +22° IMP 9.70 E N E R GY
TEMP CORRECTION PER TABLE 310.15: 0.76 VOC 48.96 SURF CLEAN ENERGY
#OF CURRENT CARRYING CONDUCTORS: 8 ISC 10.19 111 SMITHTOWN BYPASS
CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.70 SUITE#207,HAUPPAUGE,
CIRCUIT CONDUCTOR SIZE: 10 AWG MODULE DIMENSION 79.33"L x 39.37"W x 1.26"D (In NY 11788,USA
CIRCUIT CONDUCTOR AMPACITY: 40 A Inch) PHONE NO.:(866)631-7873
PROJECT NAME&ADDRESS
REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690:8(A&B-):_ ___- ___ - - ___ --- - - -- INVERTER-SPECIFICATIONS Q
1.25 X MAX AC OUTPUT CURRENT X#OF INVERTERS PER STRING (j)MANUFACTURER/MODEL# ENPHASE IQ7PLUS-72-2-US
CIRCUIT#1  : 1.25 X 1.21 X 10= 15.12A D
CIRCUIT#3  : 1.25 X 1.21 X 11 = 16.63A NOMINAL OUTPUT CURRENT 1.21 .
NOMINAL OUTPUT VOLTAGE 240 VAC �
DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 z W 0)
TEMP CORR. PER NEC TABLE 310.15 XQ
CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X PERCENT OF NUMBER OF CURRENT < z
CIRCUIT CONDUCTOR AMPACITY= 0.76 X0.70 X 40=21.28A VALUES CARRYING CONDUCTORS IN EMT
.80 4-6 2 z
.70 7-9 LU
50 1 10-20 cf) O
AC CONDUCTOR AMPACITY CALCULATIONS: 0 Lo -j
FROM LOAD CENTER TO MSP AMBIENT TEMPERATURE SPECS
RECORD LOW TEMP -150 L
EXPECTED WIRE TEMP (°C): 31' AMBIENT TEMP (HIGH TEMP 2%) 310
TEMP CORRECTION PER NEC TABLE 310.15: 0.94 CONDUIT HEIGHT 0.5"
CIRCUIT CONDUCTOR SIZE: 4 AWG Q
ROOF TOP TEMP 53° 0
CIRCUIT CONDUCTOR AMPACITY: 85A
#OF CURRENT CARRYING CONDUCTORS: 3 CONDUCTOR TEMPERATURE RATE 75° SHEET NAME
CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 WIRING
REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): CALCULATIONS
1.25 X OUTPUT CURRENT OF LOAD CENTER SHEET NUMBER
1.25 X 1.21 X 42 =63.52 A PV-7
DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15:
TEMP CORR. PER NEC 310.15 X Signature with Seal
CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X
CIRCUIT CONDUCTOR AMPACITY=
0.94 X 1.00 X 85 = 79.9A
ELECTRICAL NOTES:
1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.
2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.
3.)WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE
AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.
4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.
5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY
OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS.
6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE
THEM ACCORDINGLY.
7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.
8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE
GROUNDING CLIP MANUFACTURER'S INSTRUCTION.
9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. _
NOTES AND SPECIFICATIONS:
® • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017
• _ . . WITH ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY Now
EQUIPPESECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. SURF CLEAN
■• NOT TOUCHRAPID SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING ENERGY
TERMINALS • • ■ EFFECTIVE WORDS, COLORS AND SYMBOLS.
MAY
LABEL LocarloN: LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR BE ENERGIZED IN THE
-- --- SURF CLEAN ENERGY
OPEN POSITION. DUAL INSTALL ON EACH INVERTER. WIRING METHOD AND SHALL NOT BE HAND WRITTEN.
-- --- PER CODE:NEC 2017 690.56(C) 111 SMITHTOWN BYPASS
POWER • - - - — - ------- --— _ _ LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE SUITE#207,HAUPPAUGE,
• ■ • • NY 11788,USA
BE PRESENT - ENVIRONMENT INVOLVED.
SIGNS AND LABELS-SHALLCOMPL--Y-WITH-ANSI-Z535.4-2011., PRODUCT_ PHONE No.:(866)631-7873
LABEL LOCATION: - ® SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. - ---- — - PROJECT NAME&ADDRESS
INSTALL ON EACH PV AC DEVICE, DO NOT COVER EXISTING MANUFACTURER LABELS.
PRODUCTION METER,UTILITY METER
PER CODE:NEC 2017 690.17(E),705.12(B)(3) •UAL .•
WER SUPPLY■ SOLAR ELECTRIC CIRCUW
•, SOLAR PV ®
BREAKER IS BACKFE
•ELECTRIC
0
0
LABEL LOCATION: Z
INSTALL AT PV CIRCUIT BREAKER Q
• • ® LABEL LOCATION: WHEN BACKFEEDING C Z r
■ • 3 • . • INSTAL ON EACH PV AC DEVICE PER CODE(S):NEC 2017 690.64, G
PER CODE:NEC 2017 690.56(B) 705.12(D)(2)(3)(B)UNGROUNDEDC
• ■ G _
�L'jj
ENERGIZED vJ
LABEL LOCATION: PHOTOVOLTAIC AC Lo J
INSTALL ON EACH INVERTER. O O
PER CODE:2017 NEC 690.35(F) DISCONNECT SWITCH T
LABEL LOCATION: L
INSTALL ON PV SYSTEM
DISCONNECTING MEANS
® mm"A PER CODE:NEC 2017 690.13(B) O
U)
ztell I Will&SKIS0
SHEET NAME
DO:NOT RELOCATE THIS�
PLACARDS
-�— 11 SOALAR OUTPUT
LABEL LOCATION: ••INVERTER• BUILDING SUPPLIED BY UTILITY GRID SHEET NUMBER
ADJACENT TO PV BREAKER(IF PV-8
` ,_^
APPLICABLE). ■ BREAKERS •• AND PHOTOVOLTAIC SYSTEM �'V a
LL�• • ■ ■ • • ■
Signature with Seal
LABEL LOCATION: x
INSTALL ON AC COMBINER
0 ® � � • • 0 PER CODE:NEC 2017 690.64,
705.12(D)(2)(3)(C)
• • (E) UTILITY METER
LABEL LOCATION: (N) FUSED AC DISCONNECT
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT
EACH TURN,ABOVE AND BELOW PENETRATIONS,ON
EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE:NEC 2017:690.31(G)(3)
(N) LOAD CENTER
Z
PHOTOVOLTAIC AC DISCONNECT El
MAMMUM •. ..
NOMINALOPERATING AC VOLTAGE: (E) MAIN SERVICE PANEL
LABEL LOCATION:
Ac DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT
OF INTERCONNECTION.
PER CODE:NEC 2017:690.54
LABEL LOCATION:
POINT OF INTERCONNECTION
�: Powwvdbv
MECHANICAL SPECIFICATION SURF CLEAN
Format 201.5mmx1006mmx35-mm(includingfame)
Weight 23.5kg ENERGY
Front Cover32mm[herms9ypre-stressed glass with
sort-reflection technology
mpasltenlm .p.�•-�_- SURF CLEAN ENERGY
BockCavor c�
�• Q.r p� 111 SMITHTOWN BYPASS
•--"--"� f,,� Frame Ancdisedaluminium
•--ti•n1' '1 � - ' Cell 6 x 24 monocrystelline O.ANTUM solar half cells 0 SUITE#207,HAUPPAUGE,
a'�=•=-''' Juncitonbox 53-101 men x32-60mmx:1518mm NY 11788,USA
`,. Protection class I1?67;with bypass diodes_ _-_- -
_ _ __o-f. �\�. PHONE NO.:(866)631-7873
Cable 4mm7 Solarcabla(+)t1350mm,.(-)t1360mm -"e/`„
Connector StBubli MC4"Evo2:IP88 ____PROJECT_N_AME&AD
- DRESS
VJ
D
® • ELECTRICAL CHARACTERISTICS ^
BRANDPv: POWER.CLASS 385 390 '39r3 400 4o5 ' Q
'i>x0 RIINIMUht PERFORMANCE AT STANDARDTEST CONDITIONS,STC'(POWER TOLERANCE+5W/-0 W) Q 1_
Power a-MPP= P,,�. IW] 385 390 395 400 405 Z
eat °Z017 '2018 `'aQ' Short.Circuh Current= [A] 10.05 10.10 10.14 1019 10.23 �
Ea Open Circus val age= ,V,;: M 48.17 48.44 48.70 48.96 4922 < Z r--
•' • S Current at MPP I� [AI :.9.57 9.61 :9.66 -9:/0 9.7.5
O�� Voltage at h7pP V,_ [VI 40.24 40,57 40:90 41.23 4156
Efficiercyi 9 [%] '119.1 1_19.4 x19.6 ii9.9 120.1 5 z
MINIMUM PERFGRMANCEAT NORfd;110PERATINGCONDI710NS,NhiGT'
PawaratMpP P- [W] 288.3 292.1 295.8 299.6 33033
E Short Circuit Current IW [A] '8.10 814 8.17 821 82 �u/'1,
4 -I O 0
LO J
.9 Open Circuit Voltage Vic M 46.42 45.67 45.92 4617 46.41
Current at NIPP Iwa [A] 7.53 757 7.60 7.64 7.67 � O
Voltage at MPP V, ' '[VI 3829 38.60 38.92 39.23 39.64 '^
'foessaementtolerances Pu =3%:6&Vcx.z5%atSTC:100oW/m',25t2°C,AM 1.5 according tolEC60904-3•=800W/W.NMOT,spectrum AML5 V'
wy
LOW ELECTRICITY GENERATION COSTS 'G CELLS PERFORMANCE WARRANT`( PERFORMANCE AT LOW_IRRADIANCE
Higher yield per surface area,lower SOS Costs,higher power L?d � 11 Arleas[98%dtnomnalpa endue- E- --T----- - --- -----
i
r.;7 s.a e.t��.
classes,and an efficiency rate of up to 20.3%. W ® '- •. �. •-•«�• Ing f(rst year.Thereettet max.0.54% u i i O
------------------
rg` -- degradntlonpar year.Atleast 931°b s"� __�_____�_ I 1 � �/'►
-""--"- - of rumina aver 'to10 yenrs AI E V J
__________ I .
INNOVATIVE ALL-WEATHER TECHNOLOGY ; a least65%of nominal w
Optimal yields,whatever the weather with excellent zseasa L rti i SHEET NAME
EQUIPMENT
low-light and temperature behaviour. Al mn data within aslbetrefer- 1 ;
ares.Full werrenties In accordance.
Withthe,Janrantyiermsortte SPECIFICATIONS
ENDURING HIGH PERFORMANCE y, 0 CELLS sales oigenlsaticri of you RAa 1tX5(t:mq
respeolivacourtry..
Long-termyield securitywith Ant]LID TecKhology,And PID 3 ..;;~.gin ten _-- �a Typical module perr6rmsnceundw law lneelartce catditions in SHEET NUMBER
U Technology',Hot-Spot Protect and Traceable Quality Tra.QTI, compadsa,tosTC conditions(25-C.1000wiiro-
TEMPERATURECOEFFICIENTS PV-9
EXTREME WEATHER RATING Temperature Co.=.filcker.:ofl,s a. NII -0,04 Tempenmrscoefitefentcy= p ]%/K] -027 zi
High-tech aluminium alto"frame,certified for TFmperarsre Cosfflc:er!of P„ %/K -035 hbrmtiitvtodulaO er-tm Temperature NMOT C 433:3
,9 y - v [ 3 P a a P 1 Signature with Seal
high snow(5400Pa)and wind loads(2400 Pa). .
PROPERTIES FOR SYSTEM DESIGN R
A RELIABLE INVESTMENT MiAmum System Voliage Vs„ M 1500(IEC)/1500(UL) Safety Class II
{yo J Inclusive 12-year product warranty and 25-year t 9aximum Reverse Current I, [A) 20 Fire Rating based on ANSI JUL 1703 C/TYPE 1 of
`J linear performance warranty=. Max.Dec n Load,Push/Pull
ij [Pa]. 3600/1600 PermittadMtadutaTemperature -40°G-+85°C rT
Max-Test Lo ad.PushIPut I [Pa] b44Dj2400 onContinucusDuty
9
STATE OF THE ART MODULE TECHNOLOGY
Q.ANTUM.DUO combines cuttingedge cell separation QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION o
and innovative Wiring with Q.ANTUM Technology. IEC 6=.,2016]IEC 61730:2016,Appscstbn Class It; Number of Modules per Pallet 30
ThB data sleet compiles""with DIN EN 50380. Number of Pallets per Trailer(24t) 24
'APT test condillons according to IEc rrs 62804-1.2015,methal 13.(-.15001/.168h)
Number of Pallets per 40'HC-Container(26 1) 22
p
See data sheet on rear for further IntomemioA. OVE a
��us Pallet Dimensions(LxWxH) 2074 x1]30 x]170 mm
PalletWaighr 761kg b.
Nota Installation lrstructlons must be followed.See the insta'latica kind operating manual ci emtaclour tkhr ldal service dipartibent for father Information on approved lnslallstlon
and use of this Product. 9
THE IDEAL SOLUTION FOR: MadolnChina
Rooftop annoys on AF97 Ground-mounted u
commercisl/Indu3dal sola power plarss HenwhLOCE115 Blue
Street,
etPtyth ' {.
buildings Sulfa 1,Level 1,15 Blrxr Strew.NanhSWney,NSW_O6D.Aussafla l.TEL 461(0)2 9018 30331 FAX+61(0 901530321EMAIL q-cels-atevdm@q-eelh.cunlWEBwww.ry-ceAs.ean/au a
Engineered in Germany CELLS Engineered in Germeny CELLS
SURF CLEAN
ENERGY
Data Sheet Enphase IQ 7 and IQ 7+ Microinverters SURF CLEAN ENERGY
Enphase Microinverters
Region:AMERICAS INPUT DATA(DC) IQ7-60-2-Us IQ7PLus-72-2-us 111 SMITHTOWN BYPASS
Commonly used modulepairings' ' 235 VJ 350 W+ 235 W-440 W-+-,-,- SUITE#207,HAUPPAUGE,
— --— --------- __- _ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules NY 11788,USA
--M axlmummputDGvoitage � a8 V_ y r- m °60V "- ""-__ r___.______ _ ,__.______ ___i PHONE NO.:(866)631-7873
Peak power tracking voltage 27 V-37 V 27 V-45V---- --� - - - PROJECT NAME&.ADDRESS
Operating range 16 V 48 V 16 V 60 V u p!
Min/Max start voltage --2-2,-V,f-4,-8-V-- w 22 V f 60 V
Max DC short circuit current(module
The high-powered smart grid-ready overvoltage class DC port 11 11
EnphaseM DC port backfeed current _ O A __. _Y. _0 A
Enphase IQ 7 Micro and Enphase IQ 7+Micro _ _.__
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
dramatically simplify the installation process while AC side protection requires max 20A per branch circuit Q
achieving the highest system efficiency.
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Microinverters Peak output power 250 UA _4__ - 295 VA Y __ _.e_-____ .__
Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power __ 240 VA 290 VA Q
Nominal(L-L)voltage/range= 240 V/ 208 V% 240 V/ 208 V� C
IQ 7+Microinverters integrate with the Enphase 211-264V 183-229v 211-264V 183-229V G Q
IQ Envoy-,Enphase IQ Battery-,and the Enphase maximum continuous output current � 1.0 A(240 V) v_ 1.15 A(203 V)� _1.21 A(240 V) 1.39 A(208 V)
Enlighten'"'monitoring and analysis software. Nomina_unuenpy � m. ._ _ ___._. "60 Hz _ __ 60 Hz _ i � Z
Extended frequency range 47-68 Hz 47-68 Hz UJ
ACshort circuit fault current over 3 cycles 5 8 Arms - �5.8_Arms
IQ Series Microinverters extend the reliability — - - y - -- --4-_- U) C) J
Maximum units per 20 A(L L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC)
standards set forth by previous generations and overvoitage class Ac port ur `_ u ._. !II _ �_ v_
AC port backfeed current 0 A 0 A _
undergo over a million hours of power-on testing, __ ___.____._ _ ____._ ____._.._r.__.—___.. _. . ._ ._.._ ...___._. ..-.. _ -__ -_.- ._._. __ .___._, --_ ___. -__ _r___,
Power factor setting 1.0 1.0 -- r
enabling Enphase to provide an industry-leading -- fact - _-. _..- _._ -_.. _ ___.. _ LO �
Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging
warranty of up to 25 years. EFFICIENCY @240 v @208 v @240 v @208 v
Peak efficiency 97.6%- 97.6% 97.5% 97.3% I O
CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% )'^
MECHANICAL DATA V
Ambient temperature range 40'C to+65'C
_,_.._� _... _ ._ . - ___._" _ �__ SHEET NAME
Relative humidity range Oro to 100%(condensing)
Easy to Install Connector type(IQ7 b0-2-US&IQ7PLUS 72 2-US) MC4(orAmphen-1 H4 UTX with additional Q-DCC 5 adapter) _
Dimensions(WxHxD) 212 mm x 175 mm x 30 2 mm(without bracket)
Lightweight and simple ,Weight - - - -_ 1 66 kg(2 38 ibs)
f ' .'' Faster installation with improved,lighter two wire cabling - ` �� -_ __ ___ ___._ . ____.. __._ _ _ __ _-_.__._.__ .._ _- SHEET NUMBER
a P 9 9 Cooling Natural convection No fans
Built-in rapid shutdown compliant(NEC 2014&2017) Approved for w et locations Yes ��_
�_-.-_,_ ____ __._ �__ — __ ____ _-____ _- _____ _�_ __..____.�..._ _ -_---- N_- _, -- _.. ____._ __
�� Pollution degree PD3
1 0
41
'Enclosure Class II double insulated,corrosion resistant polymeric enclosure -
%" Productive and Reliable ____ ._ _ __ _ __ __-.___.,._____ . . _. _. _ . _____ -. -. _ _ __ __ _ __.__._ Signature with Seal
Environmental category/UV exposure rating NEMA Type 6/outdoor
- Optimized for high powered 60-cell and 72-cell*modules FEATURES
More than a million hours of testing Communication�a _ Power Une`Comrnunication(PLC)
Class 11 double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options.
Both options require installation of an Enphase IQ Envoy.
UL listed _v __.____..__ ..__ __.__.___.__, ..-___. ____ .__ -- ___.._
Disconnecting means The ACand DC connectors have been evaluated andapproved by UL for use as the load break
o disconnect required by NEC 690.
Smart Grid Read Compliance CA Rule 21(UL 1741-SA)
Y UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,
Complies with advanced grid support,voltage and CAN/CSA-C22.2 NO.107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
frequency ride through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
• Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions.
grid requirements
Configurable forvarying grid profiles
Meets CA Rule 21(UL 1741-SA)
'The IQ 7+Micro Is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at httos,/!enphase com!en-us/support/module-coin atip bility-
U` 2.Nominal voltage range can be extended beyond nominal if required by the utility. SPECIFICATIONS
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
ENPHASE.E• To learn more about Enphase offerings,visit enphase.com ENHAS E•
To learn more about Enphase offerings,visit enphase.eom G 2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc,
2019-3-26
r
SURF CLEAN
ENERGY
SURF CLEAN ENERGY
111 SMITHTOWN BYPASS
Data Shea Enphase IQ Combiner+ SUITE#207,HAUPPAUGE,
Enphase Networking— --- — _ _ _ NY 11788,USA
--- -- - - PHONE NO.:(866)631-7873
MODEL NUMBER - - - — __ PROJECT_NAME_&ADDRESS —
IQ Com6iner+X-IQ-AM1-240-2 IQ Combiner+with Enphase IQ Envoy"for integrated revenue grade PV production metering ��)/
(ANSI C1220+/-0.5%)and optional*consumption monitoring(+/=2.590. v
ACCESSORIES(order separately)
Enphase Mobile Connect-
The Enphase(Q Combiner+` With Enphase 'CELLMODEM-03(4G/12-year data plan) Plug and Play indu"striai grade cellular modem with data plan for systems up to 60 r
EnphaseCELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US virgin Islands, Q
n CELLMODEM-M1(4G LTE CAT-M1 15-year data plan) where there is adequate cellular service in the installation area.) < �y
IQ Envoy ' consolidates interconnection _ _ . _ __ _ _. ._ _._ -_. _ _ _ _ ___ - _ .. _ _ LL O
IQi r+ Consumption Monitoring CT �
equipment into a single enclosure and CT-200-SPLIT Split core current transformers enable whole home consumption metering*(+/ 2.595).
r
(X-IQ-AM1-240-2) streamlines PV and storage installations by
'CircuitBreaQ .�
BRK15A-2-240 Breaker,2 pole,15A,Eaton BR215
providing a consistent,pre-Wired solution for BRK20A-2-240 Breaker,2pole,20A,EatonBR220 G
ELECTRICAL SPECIFICATIONS
residential applications. It offers up to four 'Rating Continuous duty
2-pole input circuits and Eaton BR series System voltage, 240 VAC,60 Hz LO .__I .
Eaton BR series busbar rating 125 A O
busbar assembly. -_.. - --;__. . _.
Max.continuous current rating(output to grid) 65A r -T
Max.fuse/circuit rating(output) -90-A- LO �J�•
Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included)
Max.continuous current rating(input from PV) 64A O
Max.total branch circuit breaker rating(input) 80 A(any combination)
U)
Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy
Smart MECHANICAL DATA SHEET NAME
- Dimensions(WxHxD) 49.3 x 46 5 x 16 0 cm(19.4 x'18 3'x 6 3� EQUIPMENT
Includes IQ Envoy for communication
1-
and control weight - - zskg(,65lbs) SPECIFICATIONS
1 Flexible networkingsupports Wi-Fi, Ambient temperature range, _ AO°C to+46°C(40°to 115°F
1 ) o { Pp _ mP_ 9 ) SHEET NUMBER
Ethernet,or cellular Cooling Natural convection plus heatshield
i
Provides production metering and optionalPV_11
Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R polycarbonate construction
consumption monitoring
I _ , Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors
y,;- $ Supports installation of the 60 A breaker branch input:3 to 1/0 AWG copper conductors Signature with Seal
iy�Et Enphase Q Aggregator Main lug combined output: 10 to 2/0 AWG copper conductors
= Neutral and ground: 14 to 1/0 copper conductors
Always follow local code requirements for conductor sizing.
t �
i t rt ik7 t `t Simple Altitude = _ To 2000 meters(6,560 feet)
- !iVl I
f ) ' f' INTERNET CONNECTION OPTIONS
Eaton BR series panelboard interior
Integrated Wi-Fi 802.11b/ /n
v 11 15. Up to four 2-pole branch circuits for 240 VAC 9 _ -_g
plug-in breakers(not included) Ethernet 802.3,CatSE(or Cat 6)UTP Ethernet cable-not included
) � 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)(not included)
tiA y COMPLIANCE
> w
Compliance,Combiner UL 1741
Reliable -
CAN/CSA C22.2 No.107.1
Durable NRTL-certified NEMA type 47 CFR,Part 15,Class B,ICES 003
3R enclosure _. ._ _ Production metering:ANSI C12.20 accuracy class 0.5(PV production)
Compliance,IQ Envoy UL 916
Five-year warranty CAN/CSA C22.2 No.61010-1
UL listed
*Consumption monitoring is required for Enphase Storage Systems.
U�
To learn more about Enphase offerings,visit enphase-com
LISTEDC A p®�d�G`C• 0 201 R Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. �������•
To learn more about Enphase offerings,visit enphase.com ENPHASE.�1J G 20ta-05.02
r
SURF CLEAN
ENERGY
SURF CLEAN ENERGY
AML IRONRIDCE XR Rail Family XR Rail Family 111 SMITHTOWN BYPASS
SUITE#207,HAUPPAUGE,
- ----- — - -------
— — -— The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific NY 11788,USA
—---- ------- --- ------- -—
- PHONE NO.:(866)631-7873
Solar iS o Ally Sunny design loads,while minimizing material costs. Depending on your.location,-there is an XR-Rail to match. PROJECT NAME&ADDRESS
ft�ftOver their lifetime,solar panels experience countless U)
extreme weather events. Not just the worst storms in years,
but the worst storms in 40 years. High winds capable of
ripping panels from a roof, and snowfalls weighing m ^
enough to buckle a panel frame. ti
' Q
XR Rails are the structural backbone preventing ` _ - r
these results.They resist uplift, protect XR10 XR100 XR1000 C Z r-
against buckling and safely and efficiently XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among C Q
transfer loads into the building structure ' :- '� rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle CC Z
Their superior spanning capability no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or G
r, w
s remaining light and economical. maximizing spans up to 8 feet. more for commercial applications.
requires fewer roof attachments, :
reducing the number of roof Xc _ s'spanning capability a'spanning capability 12'spanning capability
Moderate load capability Heavy load capability O L{) J
penetrations and the amount »< Extreme load capability
f ' Clear anodized finish Clear&black anodized finish Clear anodized finish r O
of installation time. T = Internal splices available Internal splices available Internal splices availableLO
zpz
r
1 w
t
Z Rail Selection
t ' The following table was prepared in compliance with applicable engineering codes and standards.Values are
4 based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean
Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. SHEET NAME
1 EQUIPMENT
j > ° X1 A
„ s SPECIFICATIONS
1�aw, 100 PV-12
/ Force-Stabilizing Curve 1
rR, 4R, I Sloped roofs generate both vertical and lateral 120 ( Signature with Seal
3 forces on mounting rails which can cause them None r
` to bend and twist.The curved shape of XR Rails 140 XR10 ��.XR100; XR1000
is specially designed to increase strength in both ; !�
directions while resisting the twisting.This unique —;
sfeature ensures greater security during extreme 160 I f
`4- g weather and a Ys
longer system lifetime.
9
100
�
w 120
10-20
- 140 j ° i
I -
160
100
30
160
Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 1007-7
XR Rails are IronRidge offers All XR Rails are made of marine-grade 40
- compatible with a a range of tilt leg aluminum alloy,then protected with an 160
FlashFoot and options for flat anodized finish.Anodizing prevents surface t4 1
other pitched roof = roof mounting and structural corrosion,while also providing 50-70 160
" ! attachments. f ", applications. a more attractive appearance.
80-90 160
/ v,. „
s > F
•- �:.-" .� " �- � � -"� < _., a .._ ,��>:_._ ,, < ,, �:
... ..y-- .." /s - <, :s._. <-, ".,::, <r."...".. � >-...<. -", ..,... »s: ,< <.. rte.ti, >. i, nom..
I r
ZAMMARONRIDGE' L-Foot 46
SURF CLEAN
ENERGY
SURF CLEAN ENERGY
111 SMITHTOWN BYPASS
SUITE#207,HAUPPAUGE,
NY 11788,USA
PHONE NO.:(866)631-7873
PROJECT NAME&_ADDRESS____
U)
0
z � �
r
z r
W.
(n o 0
LO J
Item Number Component O O
1 FOOT, EXTRUDED L-SLOTTED Z
Part Nunibei . Description O
IFT-03-MI SLOTTED L-FOOT,MILL U)
LFT-03-151 SLOTTED L-FOOT,BLACK
SHEET NAME
EQUIPMENT
SPECIFICATIONS
1 J Foot, EXtfUC{@d_ L,- SlottedSHEET NUMBER
PV-1-3--
2
Signature with Seal
.94.
j 1,22
3.00 +
.3'1
f+ 1.88 --� 1.92
Property Value
Material I Aluminum
Finish Mill Black.
v1.10
INSs