Loading...
HomeMy WebLinkAbout46823-Z i SUEfe c TOWN OF SOUTHOLD �o ay BUILDING DEPARTMENT N TOWN CLERK'S OFFICE "o • ���s% SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) I Permit#: 46823 Date: 9/15/2021 Permission is hereby granted to: Umana, Jose 51750 Route 25 Southold, NY 11971 I To: install roof-mounted solar panels on existing accessory garage #2 as applied for per HPC approval. At premises located at: 51750 Route 25, Southold N O T' l NSI L L SCTM # 473889 Sec/Block/Lot# 63.-6-4 Pursuant to application dated 5/21/2021 and approved by the Building Inspector. To expire on 3/17/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $200.00 i i Building Inspector i FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD,N.Y. NOTICE OF DISAPPROVAL DATE: February 5, 2021 TO: Mary Schmeling(Umana) 265 Sunrise Highway#1-173 Rockville Centre,NY 11570 Please take notice that your application dated January 20,2021: For permit: to install roof-mounted solar panels on(2)accessoryygarages at: Location of property: 51750 Main Road, Southold,NY County Tax Map No. 1000—Section 63 Block 6 Lot 4 Is returned herewith and disapproved on the following grounds: The proposed construction is not permitted pursuant to Section 170 of the Southold Town Code and is subject to Historic Preservation Commission approval. Authorize ign Note to Applicant: Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. CC: file,Landmark i FIELD INSPECTION REPORT DATE COMMENTS , b FOUNDATION(IST) H ----------------------------------- �" LA FOUNDATION(2ND) z t ROUGH FRAMING.& PLUMBING y O r INSULATION PER N.Y. H STATE ENERGY CODE FINAL ��A�DDITI N COMMENTS OD 19 IiV V O Z ' rn O d b H i 00 FFOtO�ILDING DEPARTMENT-Electrical Inspector �CGG � TOWN OF SOUTHOLD 3 Awn Hall Annex- 54375 Main Road - PO Box 1179 o • S�Q Southold, New York 11971-0959 !yfjol ,e (631) 765-1802 - FAX(631) 765-9502 , southoldtownny._qov - sea ndCcD-southoldtownny.gov i APPLICTION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: g- a -7- Company Name: Lo vt- �s I ,-ek 5 a ✓ So to hw-, Name: ...f D 1i v, Tb 2� License No.: &/I, 3 o l- Me- email: a k, `J )w, h Phone No: Q6- &g- gg-21, ❑I request an email copy of Certificate of Compliance Address.: , 2 a- l ! -7 a-v JOB SITE INFORMATION (All Information Required) Name: J o S-e U,,,, � Address: Vit ad- S L)k-0 Cross Street: Phone No.: " ,, s— 6 0 Bldg.Permit#: email: J ase Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) hS�1( `D0 7L fu e c,- Check All That Apply: Is job ready for inspection?: ❑YES ❑NO ❑Rough In ❑Final Do you need a Temp Certificate?: ❑YES ❑NO Issued On Temp Information: (AII information required) Service SizeF_11 Ph ❑3 Ph 'Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead #Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: i PAYMENT DUE WITH APPLICATION i Electrical Inspection Form 2020.xlsx I i i out Uniqt,e l Mariella Ostroski,Chairperson Zr em Town Hall Annex Anne Surchm,Vice Chair ; MUTHOLD 54375 Route 25 Joseph McCarthy un�uyOAK PO Box 1179 N founded +{ r o Southold,NY 11971 Fabiola Santana = u I Allan Wexler 0� �� �� Telephone: (631)765-1802 Tracey Dwyer,Administrative Assistant RESERVATION southoldhpc@southoldtownny. og_v i Town of Southold Historic Preservation Commission i May 20,2021 I RESOLUTION.#05.2 0.21.3 Certificate of Appropriateness i i RE: 51750 Main Road,Southold,NY, SCTM#1000-63.-6-4 Owner: Umana,Jose RESOLUTION: WHEREAS, 51750 Main Road, Southold,NY is on the Town'of Southold Registry of Historic Landmarks, and 1 WHEREAS, as set forth in Section 56-7(b)of the Town Law(Landmarks Preservation Code) of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Historic Preservation Commission prior to the issuance of a Building Permit, and, WHEREAS, the applicant submitted a proposal to install roof mounted photovoltaic system panels on(2)existing accessory garages as applied for, and, WHEREAS, the applicant presented commissioners with an outline of the project during a pre- submission conference on April 1.5, 2021,and, WHEREAS, a public hearing was held on May 20,2021,where the applicant submitted final drawings of the scope of work and outlined the project for the commission,and, NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the proposed work detailed in the above referenced application meets the criteria for approval under Section 170-8 (A)of the Southold Town Code and, i BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness. i MOVER: Commissioner McCarthy i SECONDER: Commissioner Santana i AYES: Ostroski,Surchin,McCarthy, Santana and Wexler RESULT:Passed Please note that any deviation from the approved plans referenced above may require further review from the commission. Signed: ao , Tracey L.Dwyer,Application Coordina or for the Historic Preservation Commission Date: May 21,2021 i f I i I I I YORK workers STATE Compensation CERTIFICATE OF INSURANCE COVERAGE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured LONG ISLAND SOLAR SOLUTIONS INC 516-768-8876 22 HOLIDAY PARK DRIVE CENTEREACH,NY 11920 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 263991470 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 53095 ROUTE 25 3b.Policy Number of Entity Listed in Box"1 a" PO BOX 1179 DBL311522 SOUTHOLD NY 11971 3c.Policy effective period 01/14/2020 to 01/13/2022 4. Policy provides the following benefits: [K A.Both disability and paid family leave benefits. E] B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above.. Date Signed 11/17/2020 By Wig hf (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers an:authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. 013-120.1 (10-17) IIIIIIIP1°°°1°2�0°°1°1°°1101°11°111°1111111 CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDnmm 11/17/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this;certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: BRAZIER AGENCY P,VCHONN Etl:631-281-1700 FAr"C No:63I-281-0160 1490 MONTAUK HWY aooLEss:THEBR I RA EN MAIL.COM MASTIC, NY 11950 INSURERS AFFORDING COVERAGE MAIC INSURERA:ATLANTIC CASUALTY INSURED INSURERB:STATE INSURANCE FUND LONG ISLAND SOLAR SOLUTIONS INC INSURERC:LIBERTY MUTUAL 22 HOLIDAY PARK DRIVE INSURER D: CENTEREACH NY 11720 INSURER E: INSURER F, COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER MMIDDY EFF MOND EXP LIMIT LTR A X COMMERCIAL GENERAL LIABILITY X L068024292-0 08/25/202(08/25/2021 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE �OCCUR PREMISES Ea occurrence) $ 100,000 MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY JERO-CT ❑LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: $ ACOMBINED SINGLE LIMB AUTOMOBILE LIABILITYaccident) $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLYX AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LLAB HCLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION 23824675 02/18/202 02/18/2021 X STA B AND EMPLOYERS'LIABILITY TUTE EERH ANY PROPRIETOR/PARTNERIEXECUTIVE Y/N E EACH ACCIDENT $ 100,000 OFFICERIMEMBER EXCLUDED?..... N/A (Mandatory In NH) E.L DISEASE-EA EMPLOYEE $ 100,000 Ifyes,describe under DESCRIPTION OF OPERATIONS below III E.L.DISEASE-POLICY LIMIT $ 500,000 C INSTALLATION FLOTER BM058575037 02/01/202 02/01/2021 $50,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space is required) CONTRACTORS-SUBCONTRACTED WORK, ELECTRICAL WORK-WITHIN BUILDINGS,AND SOLAR ENERGY CONTRACTORS. CERTIFICATE HOLDER IS LISTED AS ADDITINONAL INSURED AS PER WRITTEN CONTRACT. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE j TOWN OF SOUTHOLD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 ROUTE 25 ACCORDANCE WITH THE POLICY PROVISIONS. PO BOX 1179 SOUTHOLD NY 11971 AUTHORIZED REPRESENTATIVE �O W� ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD I , i 265 Sunrise Hwy Suite 1-173 Rockville Centre, NY 11570 o516-353-5360 Cm et ng.co Pinfo(a�completeexpeditina.com www.completeexpediting.com ExLedieti, ng July 29, 2021 i Town of Southold Building Department Town Hall Annex 54375 Main Road PO Box 1179 Southold, NY 11971 Re: 51750 Main Rd Southold Solar Panel Application—Jose Umana Dear Building Department, i ! We represent the homeowner for the above listed address and have submitted a permit application for Solar Panels. On 7-19-21 we were informed that you needed updated plans reflecting the 2020 NYS Residential Code and 2017 NEC Code. Enclosed are the revised plans for the above listed address. Please mail the permit to us at the above address. I j If you have any questions o urther information is required, please contact us at 516-353-5360. i Thank you, i Mary Sc elin9 Complete Expediting I I i i i i I (516) 353-5360 info@completeexpediting.com www.completeexpediting.com i 265 Sunrise Hwy Suite 1-173 Rockville Centre, NY 11570 Cm o516-353-5360 et ng.co info(c�completeexpeditinq.com Pwww.comr)leteexpediting.com E2i editi, ng i August 31, 2021 I � Town of SoutholdM Building Department L V Town Hall Annex D 54375 Main Road PO Box 1179 S E P 1 3 2021 i Southold, NY 11971 BUILDING DEFT. Re: 51750 Main Rd Southold T01VIN OF S(.DUTHOLD Solar Panel Application—Jose Umana i Dear Building Department, We represent the homeowner for the above listed address and have submitted a permit application for Solar Panels. We were informed that you needed updated plans reflecting the 2020 NYS Residential Code and 2017 NEC Code along with an Electrical Application and check. Enclosed are the revised plans, electrical application and a check for$200.00 for the above listed address. Please mail the permit to us at the above address. If you have any questions or further information is required, please contact us at 516-353-5360. i Thank you, Mary Schm mg Complete Expediting { I i i i I i i (516) 353-5360 info@completeexpediting.com www.completeexpediting.com i N/F THE FIRST UNIVERSALIST CHURCH OF SOUTHOLD ` SOUTHOLD UNION FREE SCHOOL cm S 74'50'00"E CHAIN LINK FENCE N/0 PROP. LINE N9M Ouw O ural _I rTnct same OF vsanLT+n uc ;t � � DISTRICT #5 04 aw, —39.2_A cpeTi 1 W 1.7' 20.2. gz 1220.1co FRAME GARAGERESIDEN GARAGE # o z FRAME a 0 20.7 N i:;,C4 w `aLm� M GARAG t`� o /4 t&-A T-0z W9 io sa or.pulc.T DRIVEWAY gw, ASPHALT co 24.2' to NZ— Gia LN4N . N co N 74'50�00"W STOCKADE FENCE SOUTH OF PROPERTY UN' 33U'':Ul�I I N/F THE FIRST UNIVERSALIST CHURCH OF SOUTHOLD 0W.Y70 REFOUMMR WNOM A£SZOMY L9LRUMREDAWONNW80L4F70TLE FORMERLY BOOTH MLFCOIFAWY,GOWSWA CALAODWY, LP1aw ramnag F149'7WN9O K ANDTV PEAR&WATM OF IWL&47M 0677711"M . 6UARWMAneNOrTAV406 A9a8TO jmj4VnjCfaMAL7m0,XN CRADDOM TO 7HLS SWIOEYISA MAWNCFSWTXW 7"OF AE NEW WAK SWE WLrA7M LAW. I 1 or/ ccmvor7NL mor4YLawNor sawravo S611e-;&1 SURVEYED: 21 JULY 2005 7WL4WSWV2V WfiU90S6EDSLs &WL �'(/ NorsECCNSldev7OWAMMTRI/E SCALE 1"= 40' COPY. SURVEY OF DESCRIBED PROPERTY AREA = 26,081 S.F. SITUATE j OR ossa ACRES SOUTHOLD, TOWN OF SOUTHOLDSUFFOLK COUNTY, 'N.Y. SURVEYED BY SURVEYED FOR: ROMANELLI BROTHERS LLC STANLEY J. ISAKSEN, JR. P.O. BOX 294 TM# 1000-063-06-004 NEWS FFOLK. N.Y. 11956 631-7 4-5835 GUARANTEED TO: ROMANELLI BROTHERS LLC PECONIC ABSTRACT, INC. _ CENS ND VEYOR NYS Lic. No. 49 3 05R 1424 I APPROVED.AS NOTED -�2 DATE: v. a B.P.# oV FEE:'- BY: NOTIFY BUILDING DEPARTMENT 765=1802"-'8 AM TO 4 PtAl FOR THE FOLLOWING,INSPECTIONS: ;-1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONST;UC-10N MUST BE COMPLETE FOR'(..0. ALL,CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ;YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. I COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF RS9�> 9 N ZBA `�i rru�i n Tn�einioI ehinu yG BOARD I TRUSTEES i OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA� OF OCCUPANCY I ELECTRICAL INSPECTION REQUIRED i 4 IGOROUS LOAD ANALYSIS -0 3000E Birch Street,Suite 201 0 area,CA 92821 Ph:844-783-5483 DATE: 07-22-2021/Rev A FOR: YourSolarPlans, Inc. JOB: Umana, Jose 3000 E. Birch St 51750 Main Road Suite 201 Southold, NY 11971 Brea, CA 92821 USA To Whom It May Concern This letter is to certify that we have performed a structural analysis of the existing roof members that are to support photovoltaic panels, as shown on the attached report. The calculations were performed in accordance with NDS 2018, ASCE 7-16, and 2020 Residential Code of New York State. Our analysis was based on the following design criteria: Ground Snow (psf) 25 psf Sloped Snow(psf), reduced per ASCE, Sect. 7.4 23.78 psf Basic Wind Speed (mph): 135 mph Roof Slope: 18 degrees The PV module orientation: Portrait The maximum horizontal roof mount spacing: 4 ft. The maximum vertical roof mount spacing: 3.292 ft. Staggered roof mounts required? Yes Based on this analysis,we can certify that the individual existing roof framing members that support the PV panels; and the individual roof members as described in the attached report; are adequate to support the design loads as required by the various codes. This includes Dead Loads(including the weight of the PV panels), Live Loads, Snow Loads, and Wind Loads, on the roof members that support the PV panels, combined as required in the codes. If you have any questions on this or need further clarification, please contact us at your convenience. OF NEW Y co XP el Sincerely, rl- James A. Adams, S.E. NOTE: A FESS lo��� 1. Prior to commencement of work,the Solar Installer shall verify that the roof framing sizes, spacing, and spans (between supports), are as noted in these plans. The Engineer of Record must be notified if any discrepancies are discovered, before proceeding. 2. These plans are Stamped for Structural Code compliance of the roof members that support the PV solar system only. 3. These plans are not stamped for rain water leakage prevention. 4. As a precaution, old or wet snow should be removed from the roof, if the snow builds up to 18" or more. i Date of Report: 07-22-2021/Rev A Job Name: Umana, Jose I Data Input by: Kevin Nguyen Job Number: UMANA Contact E-mail: kevin@yoursolarplans.com Job Address: 51750 Main Road Contact Phone: 7148721728 Southold, NY 11971 I ABSTRACT Job Information This Report is based on Engineering calculations Data Input By: Kevin Nguyen using the input data supplied by the user, listed Job Number: UMANA under Current Input Data.The user input has not Job Name: Umana, Jose been independently reviewed by a licensed Job Address: 51750 Main Road Professional Engineer for appropriateness or City, State: Southold, NY 11971 accuracy, unless Stamped by a P.E. This Report indicates Compliance/Non-Compliance with the Current Input Data reference Codes listed below. The following items have been checked for Code Compliance: Payment Method Invoice Roof Type Sing leSpanRafters -;Load Combination#1: Ceiling Type 1/2 gyp. Bd. Wind Uplift on the Standoff attachment to Collar Tie Space 0 the Roof Framing members: Wind Uplift- Coverage% 33.6 0.6* DL Solar Frame Size 2x6@16 Ground Snow(psf) 25 -i Load Combination #2: Sloped Roof Snow Load (psf) 23.78 Supporting Rafter Strength with: DL Rf+ Lag Screw Diam. (in) 5/16 DL Solar+ Roof Live Load Lag Screw Embed. (in) 2.5 Overall Span (ft) 34 -Load Combination#3: PV Weight(psf) 3 Supporting Rafter Strength with: DL Rf+ PV Module Orientation Portrait DL Solar+Wind Down Rafter Span (ft) 14 Rail System 2Rail Load Combination#4: Supporting Rafter Roof Mean Height (ft) 15 Strength with: DL Rf+ DL Solar+ Snow Roof Slope (degrees) 18 ' Roofing Type Comp. Shingle Load Combination#5: Sloped Ceiling No Supporting Rafter Strength with: DL Rf+ Max. Horizontal Roof Mount(ft) 4 DL Solar+ .75Wind + .75Snow Max. Vertical Roof Mounts (ft) 3.292 Standoff Staggered Yes Load Combination#6: Check Additional Wind Exposure C Seismic Load Wind Speed (mph) 135 =Load Combination #7: Supporting Rafter Strength with: Wind Up-0.6 *(DL Rf+ DL Solar) I i I STRUCTURAL CALCULATIONS FOR PV INSTALLAMN y Prepared for SOLAR= 8 09' F= CNEC YourSolarPlans, Inc. 3000 E. Birch St, Suite 201 Brea CA, 92821 r USA 818-939-8098 USER: Kevin Nguyen � F COMPANY NAME: YourSolarPlans, Inc. SRC JOB ID: 28865 ------------- I'll, JOB REPORT DATE: 2021-07-22/Rev A t JOB NUMBER: UMANA �s JOB NAME:- � Umana, Jose � = JOB ADDRESS: 51750 Main Road Southold, NY 11971 A. N I AFESSIONP I i i I Program Version: 2020-05-08:7 I 844-783-5483 Contact: Support@Saler-Roof-Check.com Phone. i I i i Page 2 of 10 I USER INPUT: 1. .Ceiling Type := 1/2 gyp. Bd. 2. -Collar Tie Spacing (ft) :=-0 i 3. Roof Coverage % := 33.6 . 4. Roof Framing Size ;= 2x6@16 5. .Ground Snow "(psf) := 25 '6. Vertical Snow Load on slope (psf) ;= 23.8 '7. Lag Screw Diameter (in) A := 5/16 8. Lag Screw Embedmen:t'(in) 2.5 9. .Overall Span (ft) :_ 34 I 10. PV Weight.(psf) DLpv = 3.00 11. Rafter Sloped Span ;(ft) Lr := 14 12. Rail System 2Rail 13. Roofing Type := Comp. Shingle 14. Roof Mean Height (ft) = h 15 `15. Roof Slope (degrees) ._ := 18 i 16. Roof Structure Type SingleSpan Rafters 17. Sloped Ceiling? := No :18. Sfh = RF Mount Horizontal Spacing (ft) 4.00 , 19. Sfv = RF Mount Vertical Spacing (ft) 3.29 I 26. RF Mount. Staggered Yes 21. "Wind Exposure := C 22. Wind Speed (mph) .= V := 135 23. Lpv=PV'Length (in) 79 24: 'Wpv = PV Width (in) 39 25-Gable, Hip, or Flat/Monoslope Gable Roof j 26. Roof Overhangs Yes 27. Sr= Rafter:Spacing (ft) 1.33 28. PV Orientation Portrait 29. Elevation Above Sea Level (ft) .= Elev := 25 Page 3 of 10 FORMULA SYMBOLS: TAfp := Tributary Area to. RF Mounts with Portrait PV Dri.entation (sf) TAO Tributary Area to RF Mounts .with Landscape P.V .Orientation (s f) -T r Tributary Area to Rafters sf) Ia-f Pressure-Equalization Factor for.RF_Mounts,_with Portrait PV:Or.ien,tation _ af Pressure Eq`ualizatlon Factor for RF Mounts "With Landsca iie PV Orientation 'Y�r Pressure"Eq' Factorfor-Rafters Pifp Design Wind Pressure'to RF Mounts:Wit[! Portrait PV-.Orientation - Zone 1 (ps . P2fp Design Wind Pressure to.RF Mounts;;with"Portrait PV orientation - Zone '2 {psf) ,.PM Design Wind Pressureto RF Mounts:with Landscape .P,V:Drientation Zone':1. psf} 1?2fi benign Wind 'Pressure to',RF.MountS with La-ndscane PV Orientation -:;Zone 2 sf) .Pr,lp Design Wind:Pressure`Un to ,Rafters (psf) Prdii Design Wind Pressure"Down to Rafters -(psf) ,GCP1. := External Pressure Coefficient fo,r RF Mounts .Zone 1 (depends.-on TA Fastener) GCp2 External Pressure Coefficient for RF Mounts - Zone'2 (depends-:on TA Fastener) GCpup` := External.Pressure Coefficient; Wind Ub`for Rafters ;(depends on TAr) i GCpdn := External Pressure.Coefficient,-�Wind Down :for-Rafters_(depends on TAr) S Snow-on-Roof.(psf) sm , _. RF Mount Horizontal Spacing (ft) i sfvRF Mount Vertical Spacing-(ft} Asr Rafter Spacing (ft) Lpv; PV'Length (ft) i PV Width (ft) ,Lr Span of Rafter (ft) 'YES Edge Array Factor Page 4 of 10 Dead L6ads'(DL): psf Roofing = 2.20 1.50 Rafter- = 1.50 Miscellaneous (Misc), 1.00 CIO. joists = 0.65 InsUlation (Insul) 0.50 Ceiling 2.20 Flat Ceiling DLtc'--':'R6ofihg Ply + 110ter + Mist (OS*f): 6.20 DUc + nsu + Ceiling 's P�-T) 3.35 b wbLtc QLtex_Sr P 0 8.27 Sloped Itellifig' L COC=DL.t6N/A +jhkil. + Celling (Po), wQLtc,"—DLt6,x*.Sr �P,19 N/A DESIGN CkTERIAASCE REFERENCE Risk Category II '.Table".L5-1, Importance Factor Table 1.572' 1.00 Basic Wind Speed flg.-26,5-1b- v = 135 Wind Difectional Ity Table 26,'6-4- Kd 0.85 Exposure Category: ,Sect. 26.7.3�- C I . TopographicFattor Sect. 26.'8 Kzt = 1.00 Elevcitiofi- aboVe"Seh16V-61 Table"26,9-1 Re: 1.00 Velocity Pressure Exposure Table'26,1071 K-. 0.85 Veld . Velocity Pressure -EO -26.10-1 qh Z . 2 33.68 ,y =.00256 x K -x ,Kzt x Kd X Ke-X V Edge Array Facbar. Sect, 29,4 1.4 IE (Zone 1) =1.0 -YE(Zone2) 1.5 PV Pressure Equalization FI 29.4-8 la 0.71 Factor Page 5 of 1:0' ,RF'MOUNT- Wind OP Pressure (Note: 'Divi.de TA by 2 for 2 Rail System)- Portrait Orientation: ASCE REFERENCE TA I = Sfh k Lpv 13.17 Fig. 29.4-8 1 I'a 0.71 Fig'. 30.3 Zohe-':L: GCpi 2.00 Eq. 29.4-7 PIf = qh x'G*QpI k-iEx^fA = 48.13 Fig. 30:3-2* Zd'h'e 26- GCp 2e 2.50 - Eq. 29.4-7 -P2 e f-,-- clh.x GCp'2.x IE'x 7a90.25 Fig. 3,0.3-2 Zdile'2r: GCp2r 2.83 . E0.29. -7 P2rf =qh x GCp2r X'YE X 'Ya 102.13 karidscane Orientation: -ASCE REFERENCE 'TAfi = Sfh-x. --Wpv N/A Fig. 29.4-8 !a N/A Fig. 30.-3':2-* Zone 1:' .'GCpi NIA PIf qh x GCpj >�-it x-in Eq.2§.477' N/A Fig. 3,0'3-2* Zdn- -e; .26: GC N/A p2e Eq.29.4-7 P2ef = qhx GCp2e x^(E x"Ya N/A Fig., 30.3-2* Zone 2r: GQ p2r N/A Eq.. P2rf =q}1 x GCp2r x IE x^in, N/A *NOTE:For Flat and Monoslope Roofs, refer to Figures 30.3-5A and 30.3-513 Pagq 6 o 10 RAFTERS-Mind UP Pressure ASCE REFERENCE TAr = 8fh N-4 56.00 ar Fig.;29.4.-8 29.4_8 0.46 M Zone' 1�. G-COUP, 1.04 . !g. 3.0..13-2 Eq. 29.4-7' -Prup ch x GCpjjp X-MX.Aja 16.03 !Z,AFTERS-Wind DOWN Pressure 'ASCE REFERENCE TAr= :Sfh x Lr = 56.00 Fig..- ,29. 4-8 0.46 Fig. 50. 3.2* Zone 1: :GCpdp = 0.36 'Ply 'x GCp- 16.00 -Eq. 29.4-77 qh dn x, YE )� la LOAD:COMB. ,#'1: WIND UPLIFT ON N RF MOUNTS .(O.6DL - 0.6 .Wind.'Up) jiCd =.1.6) t.=--Withdrawal Capacity (lb/inch) t = 235.00 W= Total Withdrawal Capacity940.00 W Cd,�<t.k 0 :W TAf>((0.6 x'Plf-'0 ->VDLPV x cos(O x d6o) 357.72 % =W x I OOIPf 262.8% torn' liant if % is equal.to ' r-more than 100% -.Code, . ..p o mo ZONE 2e' 'P TAf N .. . (0.6-x P2ef- 0.6 x nLpV.x ep.s(O x deg690.46)) % = W X 1001P20 = 136.1% -Code Compliant if % is equal to-or more than, 100% z6NE 2t P TAf x (0.6 k P2rf `0.6 k DLj?V x 66s(' x de 784.30 0 M % W 1001P2rf. = 119.8% -Code Compliant if % is equal to or more than 100% :Page 7 of 10 i LOAD COMB.:#2:' 0n RaftersDL RF+ DL SoLA'R+ RF LL(CD=1.25) with LL = 20 psf i W:='LL x Sr p1f (plf) = 26.67 Psp -=TAfX DLpv = 39.50 � I 4.25 M s-- WL L- x ��. +P x L' x COS 9 398.87 Z (. ..). DL tc. sp { i L . " w x is cos.{8} Spans C':10.0 ft N/A ._ 2 xL mLL•_ I Vil Z,X`W fi {wx`cx(2xL=c}-1-wxc?}} 8p'aris :; 10.'0 ft t .- 2 x L 4 229.05 MLL'= 2x 12 627.92 -ter2 .= 2.02 :AbxCd, CLs *.—x 1Q0 CC:;Ifequal to or 'more than;100% 'Code :Compliant,.OK! = 375.0% LOAD COMB. #3: On Rafters, Zone'1 DL Rf + D.L�Solar -+:,W,ind Down (Cd '=1:G) P3=TAx(0.6 x Prd,+.D3LpV-x.COS' := 163.97 M3 - WDLt�x $ x COS(!9 x d@g)-{-_P�X_ =1092.83 Sr: �) l Max 12 = FbxCdwiridxCfXxC,.xC« 2.74 Sxx100 C,C If equal to or more-than"104% Code;Compliant, 0 K! := 275.8% i I i I i i Page 8 of 10 LOAD COMB. #4: On Rafters DL Rf + DL Solar-+ Snow (Cd=1.15) S:=Sloped Roof Snow Load (psf) = 23.78 P4:=TAfx(DL x S) 352.60 z M4 =(WDL,x 8 +P4 x a x COS�8} =2033.73 SI '12'=M4 X 7.10 FbxCdSnowxCf,xCrxCLS i SX x 100 Flo:= S <<If equal to or more than -100% code Compliant, ok! 106.5% r LOAD COMB. #5: On Rafters, Zone 1 DL Rf + DL Solar + .7SWind + :75Snow (Cd=1.6) S:=Sloped Roof Snow Load (psf) 23.78 .P5;=TA fx (DLpy=I-.75 x S) x Cosa-i-TAx 0.75 x O.0 x prdn 355.70 M S;= WDLtc X L 8 Z +PS x L x cos(8) =2145.49 a S r4x 12 r ' s FhXCdWindXCfxXCrXCLS = 5.38 -SX X100 S «If equal to or more than 100% Code .Compliant, OK! 140.5% Sr LOADING COMB. #6: CHECK SEISMIC LOADING: .0=COVE RAGE ON ROOF I Existing DL:= DLRf + Walls Walls:= 5.5 psf 15.05 ProposedDL:=ExistingDL + .DLsolar x,C = 16.06 ProposedDL <<If equal to or more than 10% Code SeismicIncrease:=100 x /—100 = 6.7%FxistingDL J Compliant, OK! SEISMIC SUMMARY: EXISTING BUILDING P.ROVISI,ONS Section 116.3- Exceptions: 1. The addition complies with the requirements for new structures: 2. The addition does not increase the seismic force by more than 10%. .3. The addition does not decrease the seismic resistance of any-structural element. i i Page 9 of 10 'LOAD ZOM0. #7: On Rafters, ZONE .1 (0.6)(DL RF + DL SOLAR) - WIND -UP (CD=1.6) P?:= TAf x (0.6 x PP-0.6 x DL.pv x Cos$) 104.13 z M,:= P.�x L —wDLr�x L x cos(9 x deg) := 456.13 I a 8 12 iS •=M X - r• 7 Fb x Qd wi,,d X Cfx x Cr X Cis .— 1.14 sXx 100 IF EQUAL TO OR MORE THAN 10 %0CODE °fa « = 660.8% Sr COMPLIANTS.OK! LIMITS .OF SCOPE OF WORK AND LIABILITY Note: 1. Prior to commencement of work, the Solar Installer shall verify that the roof framing sizes, spacing, and spans,(between supports),,are as noted in these documents. The Engin--'e Record must be notified if any discrepancies are discovered, before proceeding. 2. These documents are.Stam_ ped for Structural Code compliance of the roof members that su-pport the'PV solar system .only. :3. These documents are'hotstamped for rain water leakage prevention. 4. Asa precaution, old or wet snow should be removed from the roof, if the.snow builds up to iV or more. 5. Existing- deficiencies"which are unknown and not observable due to their being concealed inside walls or-sandwiched behind gypsum board ceilings at the time i lof inspection are not included in the scope of work. These calculations are only for the roof framing which .'supports the new PV modules. These calculations do not include a complete lateral analysis of the building, nor a prediction of the i life expectancy.of the, existing building. i i .i a Page 10 of 10 l R Appendix 'I Table 3 represents the maximum Moment (M = PL/a) resulting from point loads (RF Mounts), for any spans (L) listed. a = 2.55 €ABL.E 3 The Moment Factor"a"fora 2 Rai[System The Moment Factor"a"for a Rail[ess or Shared Rail System Staggered Unstaggered Staggered Unstaggered Length Portrait Landscape Portrait Landscape Length Portrait Landscape Portrait Landscape ` _._ _ 4 Q 4 00 2 31y L ' S 00 00 z Qd 5 00 L;=S' x.00 3.50 3.72 2.50 _L=5' _5' 5.00 5.00 5.00 5.00 L;=7' 3;60 '2.84 a 2.95- 1.83 L=7' 4.50 4.50 4.50 4.19 4 L=9' 3.03 2.59 2.34 3.44 L=9' 4.00 4.00 4.00 3.12 L=1Y' 2.77 2,25 -2.04 1.19 L=11' 4,00 4,00 3.70 2.48 4 aoo � .o L A 13' 7; � 2.61 1.88 � 1.74 _ 0.90 _ _�. 'rtr AAA 1 iL 1(T _ 4.00 3.0 3.95 _ 3.9t�+8rf __..�4# i L=IV 2451 1.68 1.50 0.86 L=15' 4./003:3_2y� 2.88 y1.78� L='17' 243 1.45 1.31 _0.76 L=,17' 4.00 2.74 2.36 1.57 L=19' 2..38 1.24 1.17 0.68 L=19' _ ~✓ 4.00 2.46 2.18 1.38 11.-'C67" $Z11'T 065 . L=21' 2.22 1.14 1.06 0.62 L=21' 4.00 2,28 2.06 3..25 REFERENCES: LATEST EDITION Duration Factors Section Modules Size Form Factor Cdwind = 1.6 Sx 7.56 S2x12 := 31.640 Cf2x2 := 1.5 Cf4x4 := 1.5 Cdsnow:= 1.15 S2x2 := 0.563 S4x4 := 7,150 Cf2x4 := 1.5 Cf4x6 := 1.3 Cd DL := 0.9 S2x4 = 3.063 S4x6 := 17.650 Cf2x6 := 1.3 Cf4x8 := 1.3 ULL .= 1.25 S2z6 := 7.563 S4x8 := 30.660 Cf2x8 := 1.2 -Cf4xio := 1.2 CLS .= 2.00 S2x8 := 13.140 S4x10 := 49.900 Cf2xio:= 1.1 Cf4x12 := 1.1 Fb = 1000 52x10 := 21.390 S4x12 := 73.800 Cf2x12:= 1.0 v N RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEM 51750 MAIN RD , SOUTHOLD, NY 11971 , USA SURF CLEAN ENERGY 42 MODULES-ROOF MOUNTED - 16.60 kW DC, 12. 16 kW AC SURF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, SHEET INDEXNY 11788,USA PHONE NO.:(866)631-7873 PV-1 COVER PAGE PROJECT NAME&ADDRESS PV-2 GENERAL NOTES - s PV-3 PLOT PLAN _ — --- - — PV-4 ROOF PLAN & MODULES Wv PV-5 ATTACHMENT DETAIL PV-6 ELECTRICAL LINE DIAGRAM �� PV-7 WIRING CALCULATIONS PV-8 PLACARDS17_ Z PV-9+ EQUIPMENT SPECIFICATIONS Pv sw Q r 5 _ f t �" `� �' ea ,r.:A,,� .° if r.. � r y 'n 4 ";- , 21" - [ 1 ' ' "d- 25 0 g , k, rr' � . y a -� i > -a, ax - IN N11 £ v r< _ 4 s r ,<. SHEET NAME t e = OVER PAGE �s SHEET NUMBER _+ x 4 y > e Signature with Seal r a r Test a D s f - r alpind 2 HOUSE PHOTO r,= �s ` ' Pv-1 SCALE: NTS SEP 3 202 r GOVERNING CODES Shelter j �� 5 50 Matn Road BUILDING DEFT ALL WORK SHALL CONFORM TO THE FOLLOWING CODES G� OF SGi1TiOLD Panic EQUIPMENT SUMMARY 1. 2020 RESIDENTIAL CODE OF NEW YORK STATE 2. 2020 BUILDING CODE OF NEW YORK STATE " e L 42 HANWHA SOLAR Q.PEAK DUO L-G7.2 400 (400W) MODULES 3. 2020 PLUMBING CODE OF NEW YORK STATE 4. 2020 MECHANICAL CODE OF NEW YORK STATE ; g 42 ENPHASE : IQ7PLUS-72-2-US (240V) INVERTERS. id 01 ENPHASE IQ COMBINER 5. 2020 FUEL GAS CODE OF NEW YORK STATE = zs �` 01 AC DISCONNECT 6. 2020 FIRE CODE OF NEW YORK STATE cutch`ague � ". 7. 2020 PROPERTY MAINTENANCE CODE OF NEW YORK STATE 8. 2020 EXISTING BUILDING CODE OF NEW YORK STATE 1 VICINITY MAP 9. NEC 2017 NYS UNIFORM CODE SUPPLEMENT 10. ANY OTHER LOCAL AMENDMENTS Pv-1 SCALE: NTS GFNERA - NOTES THE INSTALLATION OF PV SYSTEM SHALL BE IN ACCORDANCE WITH THE MOST • WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY RECENT NATIONAL ELECTRIC AND BUILDING CODES AND STANDARDS, AS INTERCONNECTION, THE BREAKERNSHALL BE INSTALLED AT THE SURF CLEAN AMENDED BY JURISDICTION OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. ENERGY • PV SYSTEMS SHALL BE PERMITTED TO SUPPLY A BUILDING OR OTHER 0 WHERE GROUND-FAULT PROTECTION IS USED, THE OUTPUT OF AN STRUCTURE IN ADDITION TO ANY OTHER ELECTRICAL SUPPLY SYSTEM(S) [NEC INTERACTIVE SYSTEM SHALL BE CONNECTED TO THE SUPPLY SIDE OF SURF CLEAN ENERGY 111 SMITHTOWN BYPASS 690.4(A)] THE GROUND FAULT PROTECTION [NEC 705.32] SUITE#207,HAUPPAUGE, • THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND • ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NY 11788,USA INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, PHONE NO.:(866)631-7873 [NEC 690.4(C)] ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PROJECT NAME&ADDRESS — • EXISTING-PLUMBING VENTS, SKYLIGHTS, EXHAUST-OUTLETS,-VENTILATIONS PLAQUE. PLAQUE SHALL--BE UV RES ISTANT-IF=EXPOSED-TO-SUNLIG HT.-- U)j INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC 0 ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SYSTEM. SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY • INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT. Q ti PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND • CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS Z 0-) CHARGE CONTROLLERS INTENDED FOR USE IN PV SYSTEMS SHALL BE LISTED THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS, < z OR FIELD LABELED FOR THE PV APPLICATION [NEC 690.4 (B)] NOMINAL, MAXIMUM SYSTEM VOLTAGE FOR DC CIRCUITS, OR 30 VOLTS Q }. • ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), FOR AC CIRCUITS, SHALL REQUIRE TOOL TO OPEN AND MARKED "DO 2 Z INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT Wo � • ALL EQUIPMENT.SHALL BE PROPERLY GROUNDED AND BONDED IN INTERRUPTING". [NEC 690.33(C) & (E)(2)] ACCORDANCE WITH NEC ARTICLE 250. • FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH i` O • SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41 TERMINALS, LUGS, DEVICES, OR CONNECTORS IN ACCORDANCE WITH _ • FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN NEC 110.14 Lo 6AWG SHALL COMPLY WITH NEC 250.120(C) [NEC 690.46] • WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE • PV SOURCE CIRCUIT, PV OUTPUT CIRCUIT, INVERTER OUTPUT CIRCUIT, AND MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). O 0 STORAGE BATTERY CIRCUIT CONDUCTORS AND EQUIPMENT SHALL BE • ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT PROTECTED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 240 [NEC AND APPROVED FOR USE IN WET LOCATIONS PER NEC 314.15. SHEET NAME 690.9(A)] • ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE GENERAL NOTES • OVERCURRENT DEVICES RATINGS SHALL BE NOT LESS THAN 125 PERCENT OF TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 SHEET NUMBER THE MAXIMUM CURRENTS CALCULATED IN 690.8(A). [NEC 690.9(B)] • EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION PV-2 • PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE Signature with Seal • PV DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS LOCATION EITHER ON THE OUTSIDE OF A BUILDING OR STRUCTURE OR INSIDE ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S NEAREST THE POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS [NEC RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING 690.13(A)] ELECTRODE. • ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 0 DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, • CONNECTORS SHALL REQUIRE A TOOL TO OPEN AND BE MARKED "DO NOT "CAUTION DC CIRCUIT" OR EQUIV. EVERY 5 FT. DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [NEC 0 CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO 690.33(E)(2)] CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER • ALL GROUNDED CONDUCTORS SHALL BE PROPERLY COLOR IDENTIFIED AS VOLTAGE OPERATIONAL RANGE. WHITE. [NEC 200.61 • SERVING UTILITY TO BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM. • THE OUTPUT OF AN INTERCONNECTED ELECTRIC POWER SOURCE SHALL BE 0 ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS CONNECTED AS SPECIFIED IN NEC 705.12(A), (B), (C), OR (D). AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. • THE HOMEOWNER IS RESPONSIBLE FOR ENSURING ALL EQUIPMENT OUTSIDE THE SCOPE OFWORK IS NEC COMPLIANT. MODULE TYPE, DIMENSIONS & WEIGHT N NUM'BER OF PANELS IN ARRAY=42 MODULES MODULE TYPE= HANWHA SOLAR Q.PEAK DUO L-G7.2 400 (400W) MODULES MODULE WEIGHT= 51.80 LBS/23.5 KG. .SURF CLEAN_ MODULE DIMENSIONS = 79.33"X 39.37 21.69 SF ENERGY UNIT WEIGHT OF ARRAY = 2238.60/903.00 =2.48 PSF SURF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, NY 11788;USA PHONE NO.:(866)631-7873 PROJECT NAME&ADDRESS (E)200A MAIN SERVICE PANEL TIED Z TO EXTERIOR UTILITY METER (E) FENCE C z_ (42) ENPHASE: IQ7PLUS-72-2-US G 330'-0" (240V) INVERTER Q �' — — � z — — _ — — PROPERTY LINE ui [] I 0 ti O 1-STORY - -- -- - - = _I L _ of � ,- -- -, e rQ I I � F- z io s a to O I I „e C Q m I = I I -f}•- Z O N m ROOF ACCESS POINT co I j x ` G I o f � b SHEET NAME -ou /—— o PLOT PLAN -I m I —— �J -I EXISTING -C SHEET NUMBER Z DRIVEWAY r I PV-3 m - --- - --- --- - -- - - - - -- - - -- - - -- - - - - -- - - - -- - - - - - - - _ Signature with Seal PROPERTY 339'-3" — — --- — R F#1 R F#2 I (20) HANWHA SOLAR Q.PEAK DUO (22) HANWHA SOLAR Q.PEAK DUO L-G7.2 400 L-G7.2 400 SLOPE:18° SLOPE:18° AZIM.: 182° AZIM.:268° NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY -SCALE AS SHOWN - INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME: 1 PLOT PLAN -ALL DIMENSIONS IN FEET - INSTALLERS SHALL UPDATE NAME, ADDRESS, AND PHONE NUMBER OF ADDRESS: PV-3 SCALE: 1/32"=1 UNLESS OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK PHONE NUMBER: N BILL OF MATERIALS ROOF DESCRIPTION EQUIPMENT QTY DESCRIPTION ROOF TYPE COMP SHINGLE SOLAR PV 42 HANWHA SOLAR Q.PEAK DUO L-G7.2 400(4'0OW) ROOF MODULE AZIMUTH RAFTERS RAFTERS MODULE MODULE TILT SIZE SPACING SURF CLEAN INVERTER 42 ENPHASE: IQ7PLUS-72-2-US(240V)INVERTERS. #1 18° 182° 2`'x6" 16"o.c. EN E R G Y #2 18° 268° 2"x6" 16"O.C. IQ COMBINER BOX 1 125A ENPHASE IQ COMBINER+WITH BUILT IN RGM, NEMA 3R SURF CLEAN ENERGY FUSED AC LOCKABLE MAIN SERVICE DISCONNECT(FUSED) 111 SMITHTOWN BYPASS DISCONNECT 1 240/120 V 10,3W 60A S NEMA 3R SUITE#207,HAUPPAUGE, ATTACHMENT 78 IRONRIDGE L-FOOT ATTACHMENTS NY .:(8,USA PHONE NO.:(866)631-7873 RAILS 4 IRONRIDGE XR100 RAILS 132" PROJECT NAME&ADDRESS RAILS 18 IRONRIDGE XR100 RAILS 168" M SPLUCE 16--SPLICE-KIT ---`— --- -- - --- ----- --- --- Q MID CLAMPS 76 MID CLAMPS END CLAMPS 1 16 JEND CLAMPS/STOPPER SLEEVE GROUNDING LUG 1 4 1GROUNDING LUG a o � zFTI � rn ROOF#1 CQC z (E)200A MAIN SERVICE PANEL (20) HANWHA SOLAR Q.PEAK DUO G Q >.. TIED TO EXTERIOR UTILITY METER L-G7.2 400 C z /70 (E) UTILITY METER SLOPE:18 W G z AZIM.: 182° (42) ENPHASE: IQ7PLUS-72-2-US (n C Q(N) FUSED AC DISCONNECT (N)JUNCTION BOX (240V) INVERTER Fn 1" EMT CONDUIT RUN IN ATTIC (N) 1-9/4"PVC UNDER GROUND % � 0 o (N) IQ COMBINER BOX CONDUIT 40'(TRENCHED) D L z n � SYSTEM LEGENDO rnITcn ❑ 200A MAIN SERVICE PANEL&POINT OF INTERCONNECTION.TIED TO EXTERIOR SHEET NAME ROOF ACCESS POINT ' ' L UTILITY METER b i. f ROOF PLAN & NEW PHOTOVOLTAIC UTILITY DISCONNEC SWITCH.LOCATED WITHIN 10'OF MSP. rn (N) 1-1/4"PVC UNDER GROUND § MODULE z CONDUIT 120'(TRENCHED) (N)78-IRONRIDGE L- FOOT (N) IRONRIDGE XR100 - r= I-TI SHEET NUMBER LCD NEW DEDICATED PV SYSTEM COMBINER ATTACHMENTS @ 48"OC RACKING SYSTEM V `, PANEL. rn - y= P V-`t 42 NEW HANWHA SOLAR Q.PEAK DUO T4 L-G7.2 400 MODULES WITH NEW 42- ; T �--n Signature with Seal ENPHASE IQ7PLUS-72-2-US INVERTERS, z MOUNTED ON THE BACK OF EACH ^ MODULES. l J ® =FIRE PATHWAY FnROOF#2 CIO =ROOF OBSTRUCTIONS iF NEw yO (22) HANWHA SOLAR Q.PEAK DUO L-G7.2 400 ® =ATTACHMENT POINTS A SLOPE:18° - - =RAFTER * , AZIM.:268° =RACKING SYSTEM II n =EXTERIOR RUN F \ - - =ATTIC RUN O/" ESS lOw`e�� NOTES: ARRAY DETAILS: PANEL TYPE: HANWHA SOLAR -SOLAR PANEL LAYOUT SUBJECT TO CHANGE TOTAL ROOF SURFACE AREA: 2709.33 SQFT. Q.PEAK DUO L-G7.2 400 1 ROOF PLAN & MODULES ACCORDING TO EXISTING CONDITIONS TOTAL PV ARRAY AREA: 910.56 SQ FT. PANEL SIZE: 79.33"X 39.37" PV-4 -SCALE AS SHOWN PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY NUMBER OF PANELS: 42 SCALE: 1/32",=1' -ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED AREA/TOTAL ROOF SURFACE AREA) - 100= 33.60% SYSTEM SIZE: 16.800 kW PV MODULE :SURF CLEAN ENERGY SURF CLEAN ENERGY BYPASS SEE (2/PV-5) FOR 'SUITE 207,OHAU PAUGE, ENLARGED VIEW OG NY 11788,USA PHONE NO. (86)631-7873 O \,126 (E) SINGLE LAYER OF PROJECT NAME&ADDRESS F NE(ij�yo @� A. q� 'P,�- - -- - - ---- - s -- - - - - COMPO_S_ITE SH-INGLE Q * * U) 4RA -A FA ZQ FSS101ft Z � Z W 1 ATTACHMENT DETAIL O LLo PV-5 O L PV MODULES O U) IRONRIDGE INTEGRATED SHEET NAME GROUNDING & END/MID CLAMP SHEET NUMBER `i IRONRIDGE XR100 RAIL - PV-5 Signature with Seal (E) SINGLE LAYER OF COMPOSITE SHINGLE 2"x6" RAFTERS @ 16" OC 5/16"X3" SS LAG BOLT WITH MIN 2%2" THREAD EMBEDMENT, ALUMN. "L" BRACKET SEALED PENETRATION W/3/8" SS BOLT & NUT IRONRIDGE L- FOOT DETAIL 2 ATTACHMENT DETAIL (ENLARGED VIE1n r PV-5 (42) HANWHA SOLAR Q.PEAK DUO L-G7.2 400(400W) MODULES (2) STRI'NG8 OF 1Q MODULES CONNECTED IN SERIES STRING& (2) STRINGS OF 11 MODULES CONNECTED IN SERIES STRING. SURF CLEAN ENERGY SURF CLEAN ENERGY I 11 BYPASS ENPHASE Q CABLE WITH SUITE#207,OHAUPPA GE, #6AWG EGC NY 11788,USA PHONE NO.:(866)631-7873 PROJECT NAME&ADDRESS -I----- - CIRCUIT#1 ------ --I - -- - -- ----- - - - - --- - U) 1 2 0 0 0 9 10 I n r ---------- TO UTILITY GRID C Z - - - BI-DIRECTIONAL UTILITY D Q z 1 2 CIRCUIT RCUIT#2 9 10 I M METER 1-PHASE,3-W U-1 � Z (4)#10 AWG THWN-2+RED 120V/240V U O Q (4)#10 AWG THWN-2-BLACKLo (1)#10 AWG THHN GND LINE SIDE TAP 0 J ti 3/4"EMT CONDUIT Lo _ (N) 125A ENPHASE IQ (E) MAIN SERVICE �-- COMBINER+ PANEL,200A RATED,240 � --r - -U-- - - - - - - -- -� WITH BUILT IN RGM, NEMA 3R O CIRCUIT#3 JUNCTION BOX ^ (E) MAIN BREAKER TO (n 1 2 0 0 0 10 11 600 V, NEMA 3 HOUSE 240 V,200A/2P UL LISTED (N) LOCKABLE MAIN ^ SHEET NAME. 10A SERVICE (TOP FED) ELECTRICAL LINE - - - - - - - - 20A DISCONNECT(FUSED) ^ DIAGRAM 240/120 V 10, 3W 20A 100A S NEMA 3R ^ SHEET NUMBER ---------- �� _ _ _ _ _ 20A 70A ^ PV-6 -` - ��- 0 f°— D Signature with Seal 20A - - - - - - - - - -c� 1 2 C 0RC 0 IT 0 10 11 - 0 0- - ENPHASE ENVO - - - -- - - -I (3)#4 AWG THWN-2 GEC (1)#8 AWG THHN GROUND 3/4"EMT CONDUIT GROUNDING 1-1/4"PVC UNDER GROUND ELECTRODE SYSTEM CONDUIT-120'(TRENCHED) 1-1/4"PVC UNDER GROUND 42-ENPHASE: IQ7PLUS-72-2-US CONDUIT-40' (TRENCHED) SERVICE INFO UTILITY PROVIDER: N/A MAIN SERVICE VOLTAGE:240V q MAIN SERVICE PANEL: 200A ELECTRICAL LINE DIAGRAM MAIN CIRCUIT BREAKER RATING: 200A MAIN SERVICE LOCATION: NORTH PV-6 SCALE: NTS SERVICE FEED SOURCE: OVERHEAD AC CONDUCTOR AMPACITY CALCULATIONS: SOLAR MODULE SPECIFICATIONS FROM ROOFTOP JUNCTION BOX TO LOAD CENTER MANUFACTURER/MODEL# PEAK DUO LHANWHNWH 400A SOLAR AR Q.Q. MODULES . AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT SURF CLEAN PER NEC 310.15(B)(2)(c): + 22° VMP 41.23 EXPECTED WIRE TEMP (°C): 31' +22° IMP 9.70 E N E R GY TEMP CORRECTION PER TABLE 310.15: 0.76 VOC 48.96 SURF CLEAN ENERGY #OF CURRENT CARRYING CONDUCTORS: 8 ISC 10.19 111 SMITHTOWN BYPASS CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.70 SUITE#207,HAUPPAUGE, CIRCUIT CONDUCTOR SIZE: 10 AWG MODULE DIMENSION 79.33"L x 39.37"W x 1.26"D (In NY 11788,USA CIRCUIT CONDUCTOR AMPACITY: 40 A Inch) PHONE NO.:(866)631-7873 PROJECT NAME&ADDRESS REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690:8(A&B-):_ ___- ___ - - ___ --- - - -- INVERTER-SPECIFICATIONS Q 1.25 X MAX AC OUTPUT CURRENT X#OF INVERTERS PER STRING (j)MANUFACTURER/MODEL# ENPHASE IQ7PLUS-72-2-US CIRCUIT#1 &#2 : 1.25 X 1.21 X 10= 15.12A D CIRCUIT#3 &#4 : 1.25 X 1.21 X 11 = 16.63A NOMINAL OUTPUT CURRENT 1.21 . NOMINAL OUTPUT VOLTAGE 240 VAC � DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 z W 0) TEMP CORR. PER NEC TABLE 310.15 XQ CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X PERCENT OF NUMBER OF CURRENT < z CIRCUIT CONDUCTOR AMPACITY= 0.76 X0.70 X 40=21.28A VALUES CARRYING CONDUCTORS IN EMT .80 4-6 2 z .70 7-9 LU 50 1 10-20 cf) O AC CONDUCTOR AMPACITY CALCULATIONS: 0 Lo -j FROM LOAD CENTER TO MSP AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -150 L EXPECTED WIRE TEMP (°C): 31' AMBIENT TEMP (HIGH TEMP 2%) 310 TEMP CORRECTION PER NEC TABLE 310.15: 0.94 CONDUIT HEIGHT 0.5" CIRCUIT CONDUCTOR SIZE: 4 AWG Q ROOF TOP TEMP 53° 0 CIRCUIT CONDUCTOR AMPACITY: 85A #OF CURRENT CARRYING CONDUCTORS: 3 CONDUCTOR TEMPERATURE RATE 75° SHEET NAME CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 WIRING REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): CALCULATIONS 1.25 X OUTPUT CURRENT OF LOAD CENTER SHEET NUMBER 1.25 X 1.21 X 42 =63.52 A PV-7 DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: TEMP CORR. PER NEC 310.15 X Signature with Seal CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X CIRCUIT CONDUCTOR AMPACITY= 0.94 X 1.00 X 85 = 79.9A ELECTRICAL NOTES: 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.)WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. _ NOTES AND SPECIFICATIONS: ® • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 • _ . . WITH ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY Now EQUIPPESECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. SURF CLEAN ■• NOT TOUCHRAPID SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING ENERGY TERMINALS • • ■ EFFECTIVE WORDS, COLORS AND SYMBOLS. MAY LABEL LocarloN: LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR BE ENERGIZED IN THE -- --- SURF CLEAN ENERGY OPEN POSITION. DUAL INSTALL ON EACH INVERTER. WIRING METHOD AND SHALL NOT BE HAND WRITTEN. -- --- PER CODE:NEC 2017 690.56(C) 111 SMITHTOWN BYPASS POWER • - - - — - ------- --— _ _ LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE SUITE#207,HAUPPAUGE, • ■ • • NY 11788,USA BE PRESENT - ENVIRONMENT INVOLVED. SIGNS AND LABELS-SHALLCOMPL--Y-WITH-ANSI-Z535.4-2011., PRODUCT_ PHONE No.:(866)631-7873 LABEL LOCATION: - ® SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. - ---- — - PROJECT NAME&ADDRESS INSTALL ON EACH PV AC DEVICE, DO NOT COVER EXISTING MANUFACTURER LABELS. PRODUCTION METER,UTILITY METER PER CODE:NEC 2017 690.17(E),705.12(B)(3) •UAL .• WER SUPPLY■ SOLAR ELECTRIC CIRCUW •, SOLAR PV ® BREAKER IS BACKFE •ELECTRIC 0 0 LABEL LOCATION: Z INSTALL AT PV CIRCUIT BREAKER Q • • ® LABEL LOCATION: WHEN BACKFEEDING C Z r ■ • 3 • . • INSTAL ON EACH PV AC DEVICE PER CODE(S):NEC 2017 690.64, G PER CODE:NEC 2017 690.56(B) 705.12(D)(2)(3)(B)UNGROUNDEDC • ■ G _ �L'jj ENERGIZED vJ LABEL LOCATION: PHOTOVOLTAIC AC Lo J INSTALL ON EACH INVERTER. O O PER CODE:2017 NEC 690.35(F) DISCONNECT SWITCH T LABEL LOCATION: L INSTALL ON PV SYSTEM DISCONNECTING MEANS ® mm"A PER CODE:NEC 2017 690.13(B) O U) ztell I Will&SKIS0 SHEET NAME DO:NOT RELOCATE THIS� PLACARDS -�— 11 SOALAR OUTPUT LABEL LOCATION: ••INVERTER• BUILDING SUPPLIED BY UTILITY GRID SHEET NUMBER ADJACENT TO PV BREAKER(IF PV-8 ` ,_^ APPLICABLE). ■ BREAKERS •• AND PHOTOVOLTAIC SYSTEM �'V a LL�• • ■ ■ • • ■ Signature with Seal LABEL LOCATION: x INSTALL ON AC COMBINER 0 ® � � • • 0 PER CODE:NEC 2017 690.64, 705.12(D)(2)(3)(C) • • (E) UTILITY METER LABEL LOCATION: (N) FUSED AC DISCONNECT INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,AT EACH TURN,ABOVE AND BELOW PENETRATIONS,ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE:NEC 2017:690.31(G)(3) (N) LOAD CENTER Z PHOTOVOLTAIC AC DISCONNECT El MAMMUM •. .. NOMINALOPERATING AC VOLTAGE: (E) MAIN SERVICE PANEL LABEL LOCATION: Ac DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE:NEC 2017:690.54 LABEL LOCATION: POINT OF INTERCONNECTION �: Powwvdbv MECHANICAL SPECIFICATION SURF CLEAN Format 201.5mmx1006mmx35-mm(includingfame) Weight 23.5kg ENERGY Front Cover32mm[herms9ypre-stressed glass with sort-reflection technology mpasltenlm .p.�•-�_- SURF CLEAN ENERGY BockCavor c� �• Q.r p� 111 SMITHTOWN BYPASS •--"--"� f,,� Frame Ancdisedaluminium •--ti•n1' '1 � - ' Cell 6 x 24 monocrystelline O.ANTUM solar half cells 0 SUITE#207,HAUPPAUGE, a'�=•=-''' Juncitonbox 53-101 men x32-60mmx:1518mm NY 11788,USA `,. Protection class I1?67;with bypass diodes_ _-_- - _ _ __o-f. �\�. PHONE NO.:(866)631-7873 Cable 4mm7 Solarcabla(+)t1350mm,.(-)t1360mm -"e/`„ Connector StBubli MC4"Evo2:IP88 ____PROJECT_N_AME&AD - DRESS VJ D ® • ELECTRICAL CHARACTERISTICS ^ BRANDPv: POWER.CLASS 385 390 '39r3 400 4o5 ' Q 'i>x0 RIINIMUht PERFORMANCE AT STANDARDTEST CONDITIONS,STC'(POWER TOLERANCE+5W/-0 W) Q 1_ Power a-MPP= P,,�. IW] 385 390 395 400 405 Z eat °Z017 '2018 `'aQ' Short.Circuh Current= [A] 10.05 10.10 10.14 1019 10.23 � Ea Open Circus val age= ,V,;: M 48.17 48.44 48.70 48.96 4922 < Z r-- •' • S Current at MPP I� [AI :.9.57 9.61 :9.66 -9:/0 9.7.5 O�� Voltage at h7pP V,_ [VI 40.24 40,57 40:90 41.23 4156 Efficiercyi 9 [%] '119.1 1_19.4 x19.6 ii9.9 120.1 5 z MINIMUM PERFGRMANCEAT NORfd;110PERATINGCONDI710NS,NhiGT' PawaratMpP P- [W] 288.3 292.1 295.8 299.6 33033 E Short Circuit Current IW [A] '8.10 814 8.17 821 82 �u/'1, 4 -I O 0 LO J .9 Open Circuit Voltage Vic M 46.42 45.67 45.92 4617 46.41 Current at NIPP Iwa [A] 7.53 757 7.60 7.64 7.67 � O Voltage at MPP V, ' '[VI 3829 38.60 38.92 39.23 39.64 '^ 'foessaementtolerances Pu =3%:6&Vcx.z5%atSTC:100oW/m',25t2°C,AM 1.5 according tolEC60904-3•=800W/W.NMOT,spectrum AML5 V' wy LOW ELECTRICITY GENERATION COSTS 'G CELLS PERFORMANCE WARRANT`( PERFORMANCE AT LOW_IRRADIANCE Higher yield per surface area,lower SOS Costs,higher power L?d � 11 Arleas[98%dtnomnalpa endue- E- --T----- - --- ----- i r.;7 s.a e.t��. classes,and an efficiency rate of up to 20.3%. W ® '- •. �. •-•«�• Ing f(rst year.Thereettet max.0.54% u i i O ------------------ rg` -- degradntlonpar year.Atleast 931°b s"� __�_____�_ I 1 � �/'► -""--"- - of rumina aver 'to10 yenrs AI E V J __________ I . INNOVATIVE ALL-WEATHER TECHNOLOGY ; a least65%of nominal w Optimal yields,whatever the weather with excellent zseasa L rti i SHEET NAME EQUIPMENT low-light and temperature behaviour. Al mn data within aslbetrefer- 1 ; ares.Full werrenties In accordance. Withthe,Janrantyiermsortte SPECIFICATIONS ENDURING HIGH PERFORMANCE y, 0 CELLS sales oigenlsaticri of you RAa 1tX5(t:mq respeolivacourtry.. Long-termyield securitywith Ant]LID TecKhology,And PID 3 ..;;~.gin ten _-- �a Typical module perr6rmsnceundw law lneelartce catditions in SHEET NUMBER U Technology',Hot-Spot Protect and Traceable Quality Tra.QTI, compadsa,tosTC conditions(25-C.1000wiiro- TEMPERATURECOEFFICIENTS PV-9 EXTREME WEATHER RATING Temperature Co.=.filcker.:ofl,s a. NII -0,04 Tempenmrscoefitefentcy= p ]%/K] -027 zi High-tech aluminium alto"frame,certified for TFmperarsre Cosfflc:er!of P„ %/K -035 hbrmtiitvtodulaO er-tm Temperature NMOT C 433:3 ,9 y - v [ 3 P a a P 1 Signature with Seal high snow(5400Pa)and wind loads(2400 Pa). . PROPERTIES FOR SYSTEM DESIGN R A RELIABLE INVESTMENT MiAmum System Voliage Vs„ M 1500(IEC)/1500(UL) Safety Class II {yo J Inclusive 12-year product warranty and 25-year t 9aximum Reverse Current I, [A) 20 Fire Rating based on ANSI JUL 1703 C/TYPE 1 of `J linear performance warranty=. Max.Dec n Load,Push/Pull ij [Pa]. 3600/1600 PermittadMtadutaTemperature -40°G-+85°C rT Max-Test Lo ad.PushIPut I [Pa] b44Dj2400 onContinucusDuty 9 STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM.DUO combines cuttingedge cell separation QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION o and innovative Wiring with Q.ANTUM Technology. IEC 6=.,2016]IEC 61730:2016,Appscstbn Class It; Number of Modules per Pallet 30 ThB data sleet compiles""with DIN EN 50380. Number of Pallets per Trailer(24t) 24 'APT test condillons according to IEc rrs 62804-1.2015,methal 13.(-.15001/.168h) Number of Pallets per 40'HC-Container(26 1) 22 p See data sheet on rear for further IntomemioA. OVE a ��us Pallet Dimensions(LxWxH) 2074 x1]30 x]170 mm PalletWaighr 761kg b. Nota Installation lrstructlons must be followed.See the insta'latica kind operating manual ci emtaclour tkhr ldal service dipartibent for father Information on approved lnslallstlon and use of this Product. 9 THE IDEAL SOLUTION FOR: MadolnChina Rooftop annoys on AF97 Ground-mounted u commercisl/Indu3dal sola power plarss HenwhLOCE115 Blue Street, etPtyth ' {. buildings Sulfa 1,Level 1,15 Blrxr Strew.NanhSWney,NSW_O6D.Aussafla l.TEL 461(0)2 9018 30331 FAX+61(0 901530321EMAIL q-cels-atevdm@q-eelh.cunlWEBwww.ry-ceAs.ean/au a Engineered in Germany CELLS Engineered in Germeny CELLS SURF CLEAN ENERGY Data Sheet Enphase IQ 7 and IQ 7+ Microinverters SURF CLEAN ENERGY Enphase Microinverters Region:AMERICAS INPUT DATA(DC) IQ7-60-2-Us IQ7PLus-72-2-us 111 SMITHTOWN BYPASS Commonly used modulepairings' ' 235 VJ 350 W+ 235 W-440 W-+-,-,- SUITE#207,HAUPPAUGE, — --— --------- __- _ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules NY 11788,USA --M axlmummputDGvoitage � a8 V_ y r- m °60V "- ""-__ r___.______ _ ,__.______ ___i PHONE NO.:(866)631-7873 Peak power tracking voltage 27 V-37 V 27 V-45V---- --� - - - PROJECT NAME&.ADDRESS Operating range 16 V 48 V 16 V 60 V u p! Min/Max start voltage --2-2,-V,f-4,-8-V-- w 22 V f 60 V Max DC short circuit current(module The high-powered smart grid-ready overvoltage class DC port 11 11 EnphaseM DC port backfeed current _ O A __. _Y. _0 A Enphase IQ 7 Micro and Enphase IQ 7+Micro _ _.__ PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; dramatically simplify the installation process while AC side protection requires max 20A per branch circuit Q achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 UA _4__ - 295 VA Y __ _.e_-____ .__ Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power __ 240 VA 290 VA Q Nominal(L-L)voltage/range= 240 V/ 208 V% 240 V/ 208 V� C IQ 7+Microinverters integrate with the Enphase 211-264V 183-229v 211-264V 183-229V G Q IQ Envoy-,Enphase IQ Battery-,and the Enphase maximum continuous output current � 1.0 A(240 V) v_ 1.15 A(203 V)� _1.21 A(240 V) 1.39 A(208 V) Enlighten'"'monitoring and analysis software. Nomina_unuenpy � m. ._ _ ___._. "60 Hz _ __ 60 Hz _ i � Z Extended frequency range 47-68 Hz 47-68 Hz UJ ACshort circuit fault current over 3 cycles 5 8 Arms - �5.8_Arms IQ Series Microinverters extend the reliability — - - y - -- --4-_- U) C) J Maximum units per 20 A(L L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and overvoitage class Ac port ur `_ u ._. !II _ �_ v_ AC port backfeed current 0 A 0 A _ undergo over a million hours of power-on testing, __ ___.____._ _ ____._ ____._.._r.__.—___.. _. . ._ ._.._ ...___._. ..-.. _ -__ -_.- ._._. __ .___._, --_ ___. -__ _r___, Power factor setting 1.0 1.0 -- r enabling Enphase to provide an industry-leading -- fact - _-. _..- _._ -_.. _ ___.. _ LO � Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging warranty of up to 25 years. EFFICIENCY @240 v @208 v @240 v @208 v Peak efficiency 97.6%- 97.6% 97.5% 97.3% I O CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% )'^ MECHANICAL DATA V Ambient temperature range 40'C to+65'C _,_.._� _... _ ._ . - ___._" _ �__ SHEET NAME Relative humidity range Oro to 100%(condensing) Easy to Install Connector type(IQ7 b0-2-US&IQ7PLUS 72 2-US) MC4(orAmphen-1 H4 UTX with additional Q-DCC 5 adapter) _ Dimensions(WxHxD) 212 mm x 175 mm x 30 2 mm(without bracket) Lightweight and simple ,Weight - - - -_ 1 66 kg(2 38 ibs) f ' .'' Faster installation with improved,lighter two wire cabling - ` �� -_ __ ___ ___._ . ____.. __._ _ _ __ _-_.__._.__ .._ _- SHEET NUMBER a P 9 9 Cooling Natural convection No fans Built-in rapid shutdown compliant(NEC 2014&2017) Approved for w et locations Yes ��_ �_-.-_,_ ____ __._ �__ — __ ____ _-____ _- _____ _�_ __..____.�..._ _ -_---- N_- _, -- _.. ____._ __ �� Pollution degree PD3 1 0 41 'Enclosure Class II double insulated,corrosion resistant polymeric enclosure - %" Productive and Reliable ____ ._ _ __ _ __ __-.___.,._____ . . _. _. _ . _____ -. -. _ _ __ __ _ __.__._ Signature with Seal Environmental category/UV exposure rating NEMA Type 6/outdoor - Optimized for high powered 60-cell and 72-cell*modules FEATURES More than a million hours of testing Communication�a _ Power Une`Comrnunication(PLC) Class 11 double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. UL listed _v __.____..__ ..__ __.__.___.__, ..-___. ____ .__ -- ___.._ Disconnecting means The ACand DC connectors have been evaluated andapproved by UL for use as the load break o disconnect required by NEC 690. Smart Grid Read Compliance CA Rule 21(UL 1741-SA) Y UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Complies with advanced grid support,voltage and CAN/CSA-C22.2 NO.107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements Configurable forvarying grid profiles Meets CA Rule 21(UL 1741-SA) 'The IQ 7+Micro Is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at httos,/!enphase com!en-us/support/module-coin atip bility- U` 2.Nominal voltage range can be extended beyond nominal if required by the utility. SPECIFICATIONS 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. ENPHASE.E• To learn more about Enphase offerings,visit enphase.com ENHAS E• To learn more about Enphase offerings,visit enphase.eom G 2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc, 2019-3-26 r SURF CLEAN ENERGY SURF CLEAN ENERGY 111 SMITHTOWN BYPASS Data Shea Enphase IQ Combiner+ SUITE#207,HAUPPAUGE, Enphase Networking— --- — _ _ _ NY 11788,USA --- -- - - PHONE NO.:(866)631-7873 MODEL NUMBER - - - — __ PROJECT_NAME_&ADDRESS — IQ Com6iner+X-IQ-AM1-240-2 IQ Combiner+with Enphase IQ Envoy"for integrated revenue grade PV production metering ��)/ (ANSI C1220+/-0.5%)and optional*consumption monitoring(+/=2.590. v ACCESSORIES(order separately) Enphase Mobile Connect- The Enphase(Q Combiner+` With Enphase 'CELLMODEM-03(4G/12-year data plan) Plug and Play indu"striai grade cellular modem with data plan for systems up to 60 r EnphaseCELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US virgin Islands, Q n CELLMODEM-M1(4G LTE CAT-M1 15-year data plan) where there is adequate cellular service in the installation area.) < �y IQ Envoy ' consolidates interconnection _ _ . _ __ _ _. ._ _._ -_. _ _ _ _ ___ - _ .. _ _ LL O IQi r+ Consumption Monitoring CT � equipment into a single enclosure and CT-200-SPLIT Split core current transformers enable whole home consumption metering*(+/ 2.595). r (X-IQ-AM1-240-2) streamlines PV and storage installations by 'CircuitBreaQ .� BRK15A-2-240 Breaker,2 pole,15A,Eaton BR215 providing a consistent,pre-Wired solution for BRK20A-2-240 Breaker,2pole,20A,EatonBR220 G ELECTRICAL SPECIFICATIONS residential applications. It offers up to four 'Rating Continuous duty 2-pole input circuits and Eaton BR series System voltage, 240 VAC,60 Hz LO .__I . Eaton BR series busbar rating 125 A O busbar assembly. -_.. - --;__. . _. Max.continuous current rating(output to grid) 65A r -T Max.fuse/circuit rating(output) -90-A- LO �J�• Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64A O Max.total branch circuit breaker rating(input) 80 A(any combination) U) Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy Smart MECHANICAL DATA SHEET NAME - Dimensions(WxHxD) 49.3 x 46 5 x 16 0 cm(19.4 x'18 3'x 6 3� EQUIPMENT Includes IQ Envoy for communication 1- and control weight - - zskg(,65lbs) SPECIFICATIONS 1 Flexible networkingsupports Wi-Fi, Ambient temperature range, _ AO°C to+46°C(40°to 115°F 1 ) o { Pp _ mP_ 9 ) SHEET NUMBER Ethernet,or cellular Cooling Natural convection plus heatshield i Provides production metering and optionalPV_11 Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R polycarbonate construction consumption monitoring I _ , Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors y,;- $ Supports installation of the 60 A breaker branch input:3 to 1/0 AWG copper conductors Signature with Seal iy�Et Enphase Q Aggregator Main lug combined output: 10 to 2/0 AWG copper conductors = Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. t � i t rt ik7 t `t Simple Altitude = _ To 2000 meters(6,560 feet) - !iVl I f ) ' f' INTERNET CONNECTION OPTIONS Eaton BR series panelboard interior Integrated Wi-Fi 802.11b/ /n v 11 15. Up to four 2-pole branch circuits for 240 VAC 9 _ -_g plug-in breakers(not included) Ethernet 802.3,CatSE(or Cat 6)UTP Ethernet cable-not included ) � 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)(not included) tiA y COMPLIANCE > w Compliance,Combiner UL 1741 Reliable - CAN/CSA C22.2 No.107.1 Durable NRTL-certified NEMA type 47 CFR,Part 15,Class B,ICES 003 3R enclosure _. ._ _ Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 916 Five-year warranty CAN/CSA C22.2 No.61010-1 UL listed *Consumption monitoring is required for Enphase Storage Systems. U� To learn more about Enphase offerings,visit enphase-com LISTEDC A p®�d�G`C• 0 201 R Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. �������• To learn more about Enphase offerings,visit enphase.com ENPHASE.�1J G 20ta-05.02 r SURF CLEAN ENERGY SURF CLEAN ENERGY AML IRONRIDCE XR Rail Family XR Rail Family 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, - ----- — - ------- — — -— The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific NY 11788,USA —---- ------- --- ------- -— - PHONE NO.:(866)631-7873 Solar iS o Ally Sunny design loads,while minimizing material costs. Depending on your.location,-there is an XR-Rail to match. PROJECT NAME&ADDRESS ft�ftOver their lifetime,solar panels experience countless U) extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing m ^ enough to buckle a panel frame. ti ' Q XR Rails are the structural backbone preventing ` _ - r these results.They resist uplift, protect XR10 XR100 XR1000 C Z r- against buckling and safely and efficiently XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among C Q transfer loads into the building structure ' :- '� rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle CC Z Their superior spanning capability no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or G r, w s remaining light and economical. maximizing spans up to 8 feet. more for commercial applications. requires fewer roof attachments, : reducing the number of roof Xc _ s'spanning capability a'spanning capability 12'spanning capability Moderate load capability Heavy load capability O L{) J penetrations and the amount »< Extreme load capability f ' Clear anodized finish Clear&black anodized finish Clear anodized finish r O of installation time. T = Internal splices available Internal splices available Internal splices availableLO zpz r 1 w t Z Rail Selection t ' The following table was prepared in compliance with applicable engineering codes and standards.Values are 4 based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. SHEET NAME 1 EQUIPMENT j > ° X1 A „ s SPECIFICATIONS 1�aw, 100 PV-12 / Force-Stabilizing Curve 1 rR, 4R, I Sloped roofs generate both vertical and lateral 120 ( Signature with Seal 3 forces on mounting rails which can cause them None r ` to bend and twist.The curved shape of XR Rails 140 XR10 ��.XR100; XR1000 is specially designed to increase strength in both ; !� directions while resisting the twisting.This unique —; sfeature ensures greater security during extreme 160 I f `4- g weather and a Ys longer system lifetime. 9 100 � w 120 10-20 - 140 j ° i I - 160 100 30 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 1007-7 XR Rails are IronRidge offers All XR Rails are made of marine-grade 40 - compatible with a a range of tilt leg aluminum alloy,then protected with an 160 FlashFoot and options for flat anodized finish.Anodizing prevents surface t4 1 other pitched roof = roof mounting and structural corrosion,while also providing 50-70 160 " ! attachments. f ", applications. a more attractive appearance. 80-90 160 / v,. „ s > F •- �:.-" .� " �- � � -"� < _., a .._ ,��>:_._ ,, < ,, �: ... ..y-- .." /s - <, :s._. <-, ".,::, <r."...".. � >-...<. -", ..,... »s: ,< <.. rte.ti, >. i, nom.. I r ZAMMARONRIDGE' L-Foot 46 SURF CLEAN ENERGY SURF CLEAN ENERGY 111 SMITHTOWN BYPASS SUITE#207,HAUPPAUGE, NY 11788,USA PHONE NO.:(866)631-7873 PROJECT NAME&_ADDRESS____ U) 0 z � � r z r W. (n o 0 LO J Item Number Component O O 1 FOOT, EXTRUDED L-SLOTTED Z Part Nunibei . Description O IFT-03-MI SLOTTED L-FOOT,MILL U) LFT-03-151 SLOTTED L-FOOT,BLACK SHEET NAME EQUIPMENT SPECIFICATIONS 1 J Foot, EXtfUC{@d_ L,- SlottedSHEET NUMBER PV-1-3-- 2 Signature with Seal .94. j 1,22 3.00 + .3'1 f+ 1.88 --� 1.92 Property Value Material I Aluminum Finish Mill Black. v1.10 INSs