Loading...
HomeMy WebLinkAbout47319-Z rr VOL Ir� Town of Southold 4/29/2022 P.O.Box 1179 co x�T 53095 Main Rd 4,j a°� '� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43021 Date: 4/29/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 2000 Hyatt Rd, Southold SCTM#: 473889 Sec/Block/Lot: 50.-1-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/13/2021 pursuant to which Building Permit No. 47319 dated 1/11/2022 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"accessory generator as applied for. (Maintain proper clearances) The certificate is issued to Pants View 2 LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47319 3/22/2022 PLUMBERS CERTIFICATION DATED -- Authorized Signature fuFoc TOWN OF SOUTHOLD BUILDING DEPARTMENT C. TOWN CLERK'S OFFICE "o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47319 Date: 1/11/2022 Permission is hereby granted to: Pants View 2 LLC c/o Anthony Bonsignore 200 Park Ave S FI 8 New York, NY 100031526 To: legalize "as built" generator as applied for. At premises located at: 2000 Hyatt Rd, Southold SCTM #473889 Sec/Block/Lot# 50.4-2 Pursuant to application dated 12/13/2021 and approved by the Building Inspector. To expire on 7/13/2023. Fees: AS BUILT-ACCESSORY $200.00 ELECTRIC $170.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $420.00 Build Inspector OF SO�ry®l � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.deviinCa-)town.south old.ny.us Southold,NY 11971-0959 cOUNT`I,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Pants View 2 LLC Address: 2000 Hyatt Rd City:Southold St: NY zip: 11971 Building Permit#: 47319 section: 50 Block: 1 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Platinum East Electric License No: 34091 ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 22kW Generac Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: Date: March 22, 2022 S.Devlin-Cert Electrical Compliance Form OF SOUTyOIo H 1 3 1 � -Q-O v o #' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION `IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] -INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O REMARKS: ;t DATE /-�,-2, INSPECTOR aOF SOUlyolo LklI '' * # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 i INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [VA FINAL GEN6f-J3-VdL ] 'FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] 'ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: . c./<- Fc2 DATE N-1°i Zz INSPECTOR t 1 ; sk- FIELD:INSPEC 'IUN REP RT TATE `, COM�VINxS S. i, ro . . 1 t rIt FOUNDATl .., STS s y .1 11 ..� od v' YT 57l faS , s' w,,.'....'.Y,.i 5 S 7' .c. "s1 J t . (j Ir . , I i aka y u` In ,,:}.. .. i 1 1 s y x' -y,.r t� t rt.7' t 4 tb t iJ J� 11 C t r' ., , i t to J l Cd L.q E �+ .FOUNDATION (2ND) . a �, a c\ i . .. 4. .0 .41.t:.�. 3fafil,,tt .'t :.:.'. t ? b �. l _ ti t . s t .:7 ,e...- ,S. Z. . . . . O 1..371, { t f X Y. 1 r1. ,. IR , - :'• ' ?' 1 .... Y kr,yk uI. tp H f 6 ROUGH FLING - . 7. . :.. ... •PLUMBIN:G:''.' . .: .. 4',,z �l ti . , :• 1. . . sx } u 1. Q .._ aF.,�,. ?it a t rw h .. ;:.,. ..- ..'/ J�}_�.n,.: ice,... ,'. 4 . Y J t Z,.E 1 t q J 1 , INSULATION pIt N ;� 11� H. ; R ' :. 'STATE E1V�RGY'COIbt-:: :: a . . • . 1 j- rt S3V it .. sr. 1 t 2 �J r t7 .�:. ..s. \x. //�y ]Ili" . . {q-S'•l P J.• 1 ty Y .. r c,y.$ t'r0, r mF.rr,'..I .. Fll1A n r L r,f I,k'F (: 1V , I 11 . ? •y 1 !Ns Jx ! �t fi: l " . t { trl F t; F t o 1'3,19 f .. :. fSl �.:..:( .:. '. R"... t r4F t�. li ' . . .r . nxQi �Fxtp �' s UIAJ C. / . actGtt f. �� r{+ r C l 1.4 , m 0 ` ` 7 Y .I 4 < 2M4n } .. 111 ( . '\ iso..;;{��,:;:„` (;' F , y �' r �; '. ' . ' , t F . ... •�` . ( .. 4 1 MM `J ..• . �. 7_ \ . .Ia �( y . W r.' . I : . ; . { L IY Z . . t r V l� F..'.... / 5 , .. . y . :.. : . :' :. ::..:.: .<<`:.� n . �y r n V 7 7. 'j yet \ k. ` Y ti „,� H. % P—,.1 }IJ J\r 7\'Iw it J . -.• .:,..I` �t L. Y r 1:.� M1 3`tt^'kJ ai .J t,i . r ,.-,.....\ .. .a,..:r.,sir, . :. . ±::iE�� . :.y:.: 5,`S e ... r : ^ � J' , "n' r f .t t =o�oSofFotK�oGy� TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax(631)765-9502 https://www.southoldtommU.ggv . f Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ® E C E Pn/7 E PERMIT NO. Building Inspector: DEC 1 3 2021 Applications and forms must be filled out in their entirety.Incomplete applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT. TOWN OF SOUTHOLD Ownees Authoriiatiod,foriii(Page 2),shall be completed Date: OWNER(S)OF,PROPERTY. Name:Pants View 2 LLC c/o Anthony Bonsignore SC TM#1000-050-01-002 Project Address:2000 Hyatt Rd, Southold, NY 11971 Phone-#:.-212-768-4500-.----.-- ---- -- Fm"- P9nsignore@agsny.com Mailing Address:200 Park Avenue South, 8th Floor, New York, NY 10003' CONTACT PERSON: Name:Anthony Bons ignore (Altman, Greenfield & Selvaggi) Mailing Address:200 Park Avenue South, 8th Floor, New York, NY 10003 Phone# 212-768-4500 Email:ABonsi_qnore@agsny.com DESIGN PROFESSIONAL INFORMATION: Name:Elizabeth Roberts Architects Mailing Address:168 7th St 3C, Brooklyn, NY 11215 Phone#_718-504-5488 Email:filings@elizabethroberts.com CONTRACTOR INFORMATION Name:North Fork Wood Works Mailing Address:810 Travelers St, Southold, NY 11971 Phone#:631-298-7900 Email:kyle@nfwoodworks.com DESCRIPTION"OF PROPOSED;CONSTRUCTION:~ ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: [i]other Generator(as-built) $ Will the lot be re-graded? ❑Yes BNo Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes®No IF YES,PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are` punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Elizabeth Roberts BAuthorized Agent ❑Owner Signature of Applicant: LC/ fL - Date: '' I L 1A 11_ 11VV` STATE OF NEW YORK) MRI Al NIA Notary Public,Mate of N,�W1'cf`,c SS: No.01 M16108`u3 COUNTY OF Kings ) Qualified in Queens County Commission Expir®s April 19,20� Elizabeth Roberts being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Architect (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to$he-best of-his/her-knowledge:andbel,ief;•and., that the work will be performed in the manner set forth in the applica`fion file therewith Sworn before me this Notary I",UiJilvL....i.Li�. :J ft,:;�i� .`Ai, No,01 Mi610 63 day of �� ,200 ' I' Qualified in Queens Count. r Comm!SWM pra 119,20 PROPERTY OWNER AUTHORIZATION K ._ (Where the applicant is not the owner) Anthony Bonsignore, Pants View 2 LLC 200 Park Ave. South, 8th Floor I, residing at New York, NY 10003 do hereby authorize Elizabeth Roberts, R.A. to apply on my behalf to the Trr of outhold Building Department for approval as described herein. Owne Signature Date Anthony Bonsignore Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o - Town Hall Annex--54375-Main-Road --PO-Box 1179 - _ W_ Southold, New York 11971 0959 Telephone (631) 765-1802'- FAX (631) 765-9502 @southoldtownn�,gov seand(a�sotatholdtownnygov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORM Required) Date: 12/1/21 - ---- _. Company Name: Platinum East Electric, Inc. Electrician's Name: Keith vonEiff License No.: 34091-ME Elec. email: plateastl@yahoo.com Elec. Phone No: 631-765-9424 D I request an email copy of Certificate of Compliance Elec. Address.: 1320 Kennys Road,Southold NY 11971 JOB SITE INFORMATION (All Information Required) Name: Pants view 2 LLC Address: 2000 Hyatt Road,Southold NY 11971 Cross Street: Soundview Avenue Phone-No.: 718-504-5488 Bldg.Permit#: email: filings@erizabethroberts.com -Tax Map District: . _ 1000 - Section:50 Block: 1 Lot:2 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Installation of 22KW Generac air cooled propane generator L Square Footage: Circle All That Apply: Is job ready for inspection?: .YES❑NO ❑Rough In ❑1 Final Do you need a Temp Certificate?: ❑ YES ]NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service[]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground LateralsF11 1 []2H Frame-- _-. Pole.-Work done on Service?. - ]Y N - Additional Information: PAYMENT DUE WITH APPLICATION- - J - SPIKE - -- 0' ELEV. 37.7 65 ``� MIXED SAND 0' LOAM FINES O >> h� 20 �ry �� BROWN ��. SIEY SAND C C GRAVEL IN LAYERS 31 ' WATER IN pp S R10 o Syp F CLAYEY SAN - 6 Li°,o a.7 SC W/GRAVEL IN LAYERS 16.4' ,(o• J��3j `ScP i � 5B' /FOp� ° 13.7' P ®® ?3p�, IKE WATER IN Al BROWN k, p :,:;:: : ? S'' BAY UNIT 54.9' STORAGE BIN FINE TO o COARSE SAND `1�P :�::.i�?GAO G'.:'•::.:•:::�,p: WELL 'v STONE GRAVEL DRIVEWAY �B P JUNE 10 2020 64' 28'',:.;'.:;:•: :::;'. STOOP 4 , SPIKE BAY McDONALD GEOSCIENCE ? .;..•.;•:�:��:.• Q' 6'sT S.C.T.M.#1000-50-1-2 0 6 °c 16,004.61; SQ.FT. S F 0.37 ACRES 0 00 qSA FiycF �^ 60 )> 6 o cc) LA LO \ GgTF C) c3� O s Cn \ o 00 PLOT PLAN NOTES c/) N Q� PLOT PLAN MAP INFORMATION TAKEN FROM SURVEY DONE BY KENNETH M WOYCHUK LAND SURVEYING, PLLC. 00 P.O. 153 AQUEBOGUE, NEW YORK 119. N SURVEY OF PROPERTY SITUATED IN SOUTHOLD,TOWN OF J�4 SOUTHOLD,SUFFOLK COUNTY, NY. 00' S.C.TAX MAP No.: 1000 SECT.50 BLOCK 1 LOT 2 REBAR - — SURVEY DATED:JUNE 10,2020 ER V - PROJECT - TITLE- NUMBER SK-01 ELIZABETH ROBERTS ARCHITECTS 2000 HYATT RD SITE PLAN SCALE 1:20 - - - -- -- - - - - DATE 12/09/2021 168 7TH STREET 3C BROOKLYN,NY 11215 APPROVED AS NOTED DATE: A as B.P.# 3 FEE: BY: NOTIFY BUILDING DEPARTMENT AT 765-1802- 8 A TO 4 P FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH FRAMING & PLUMBING 3. INSULATION ELECTRICAL 4. FINAL - CONSTRUCTION MUST INSPECTION REQUIRED BE COMPLETE FOS C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF 6t6fi6WNIBA—, S( 'fHOF-MWN-P NNING BOARD -SOUTHOLD TOWN TRUSTEES XY D C OCCUPANCY OR US�,�IS UNLAWFUL WITHOUT CERTIFICI OF OCCUPANCY F- GENERAC® _ 20/22/24 kWGUARDIAN° SERIES _ Residential Standby Generators Air-Cooled Gas Engine _ MEN-- Standby Power Rating INCLUDES: G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True Power"Electrical Technology G007042-2.G007043-2,G007042-3,0007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209-0,G007210-1(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution-controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard WI-Fi®connectivity • System status&maintenance interval LED indicators! • Sound attenuated enclosure _VAI • Flexible fuel line connector • Natural gas or LP gas operation GENERAC =. • 5 Year limited warranty ` • Listed and labeled for installation as close as 18 in(457 mm)to a structure.* " *Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. IS.or C s US QU' n LISTED �X Note:CETL or CUL certification only appplies to unbundled units and units Packaged with limited circuit switches.Units pacted with the Smart Switch are il.or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER—ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE.SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. FANERAC T•�.OMISES ��' _ GENERAC® 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls - -Rigid construction and added durability provide long engine life.-- - _ — - -- -- - • Electronic ignition/spark advance - - These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution—Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC® 20/22/24 kW _Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector____ _ _ - Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required_connection to the gas supply piping. — - • Integral sediment trap - — - - - Meets IF6Gand NFPA 54 installation requirements.- Connectivity equirements Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GEMERAC' 20/22/24 kW Specifications Generator Model 6007038-1 G007042-2 G007038-3 G007D42-3 G007209-0 G007039-1 G007043-2 G007039-3 G007043-3 G007210-1 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) Y~ 20,000 Watts' 22,000 Walls` ' 20,000 Watts` 22,000 Watts` 24,000 Watts'-� Rated maximum continuous.power-capacity.(NG).__-_- 18,000 Watts` 19,500 Watts` 18,000 Watts` 19,500 Watts' 21,000 Watts'_ ftatedvoltage _— 240 � _i Rated maximum continuous load.current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3/75.0 91.7/81.3 100/87.5 ' Total Harmonic Distortion • - Less than 5% _ Main line circuit breaker90 amp -N 100 amp ~ 90 amp 100 amp 100 amp Phase —�_... � 1--- --I Number of rotor poles 2 Rated AC•frequency Power factor �-- ��-- - - 1.0 8atteryrequirement(not included) y' 12 Volts,Group 26R 540 CCA minimumer Groep 35AGM 650 CCA minimem Unit weight(lb/kg) 448/203 466/211 _ 436/198 445/202 455/206 Dimenslons(LxjxA)In/cm 48x25x29/121.963.5z73_.7 _ Sound output in dB(A)at 23 It(7 m)with generator operating at normal load" _ 67 67 67 67 67 Sound oritput in dB(A)at 23 it(7 m)with generator)n quiet-Test'"low-speed exercisemode` 55'� 57 55 57 57 Exercise duration - w 5 min Engine Engine type GENERAC G-Farce 1000 Series _ Number of.cylinders a 2 v _� Displacement 999 cc — I Iilnnder tibc lok _ — _ Aluminum w/cast iron sleeve ____ --� Valve arrangement Overhead valve Ignition system _ _ Solid-state w/magneto Govemorsystem _ - — Electronic Compressionratio �-.� _ — — 9.5:1 Starter 12 VDC Oii capacity including f[Iter _- w�APPnox.1.9 qt/1.8 L Operating rpm — — 3,600 Fuel consumption Natural gas tt3/hr(m3/hr) 204(5.78) 228(6.46) 164(4.64) 203(5.75) 1/2 Load Full Load 301'(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane 1`13/hr(gal/hr)[Uhr] Ful Load 87 130(3.56)[13.48] 14292(3.90)[14.77] 136 86(3.74)[184.15] 142 92(3.0)[14.77] Full Load_ _ _ Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply 03/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons:AUTO - — Automatic start an utility failure.Weekly,Bi-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF _ Stops-uni_t'.Power'is removed.Control and charger still operate. i Ready to Run/Maintenance messages Standard _ Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) - -- - —.___-_� y___._______ ._ Utility Voltage Loss/Retum to Utility adjustable(brownout setting) From_ 190-171 V/190-210 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out — Starter cannot re-engage until 5 sec after engine hus stopped. Smart Battery Charger Standard Charger FaulVMissing AC warning `�� _ Standard ^"-^— Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation Over,and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard [Safety Fu§ed/Fuse Problem Protection Standard- Automatic Low Oil Pressure/High 011 Temperature Shutdown Standard Overcrank%Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown _ Standard High Engine Temperature Shutdown _ Standard Internal FaulVlncorrect W]ting protection_ y Standard�J_ Common external fault capability Standard Field upgradable firmware _ Standard 1 `"Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6°C)above 60°F(16°C). GENERAC® 20/22/24 kW Switch Options Service BalBd Automatic Transfer Switch Features G097039.1,G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Model 6007043.2,0007043-3(22 kW) _ G007210-1(24 kW) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction No.of poles 2 with Smart Management Modules(SMMs). ---Current rating(amps) 200 - — - • Electrically operated,mechanically-held contacts for fast,clean connections. - - Voltage rating(VAC) 120/240,10 • Main breakers are rated for 80%continuous load. Utility voltage monitor(fixed)* -Pick-up 80% r • 2-pale,250 VAC contactors. -Dropout 65% • Service equipment rated,dual coil design. Retum to Utility" �I Approx.13 sec EiL or UL listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly W. 200 Amps 120/240,18 Open Transition Service Rated H1 Height H2 W1 W2 Width Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 "' Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 oEam WW2 GENERAC® 20/22/24 kW Available Accessories CM 04 _ Model# Product Description ^ 04 G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. ' of G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit_______ _ ___needed.Not compatible with 50 amp_pre_wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485 0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). F G007005-0 Wi-Fi LP Tank Fuel Level The Wi-F enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the' Monitor LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected power failuresta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-413 LTE Mobile Linkq'Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-WI-Fl/ Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snapinto the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 637.6 mm 1218 mm G007038-1 696471074185 [25.1 In] [48.0 In] G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 zas nM G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 o a o I G007209-0 696471071511 l I G007210-1 1 696471084801 646 mm 1232 mm [26.61n] [48.61rp LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com 02021 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.AODOO937814 Rev.D 04/14/2021