Loading...
HomeMy WebLinkAbout46558-Z �o�g0FF01�-�oG Town of Southold 4/29/2022 �. P.O.Box 1179 o - C* 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 43017 Date: 4/29/2022 THIS CERTIFIES that the building ALTERATION Location of Property: 2175 Pine Neck Rd., Southold SCTM#: 473889 Sec/Block/Lot: 70.-5-48 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/8/2021 pursuant to which Building Permit No. 46558 dated 7/13/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alterations to existing single-family as applied for. Violation:As per Southold Town Code, Section 144-8, an accessory apartment in the accessory garage has been constructed without a building permit or Suffolk County Health Department approval. The certificate is issued to Lindh,Alexander of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R-21-1244 4/21/2022 ELECTRICAL CERTIFICATE NO. 46558 12/15/2021 PLUMBERS CERTIFICATION DATED 2/15/2022 n i&ME rth Plu ng th r' ed ignature �,�suFFai�c TOWN OF SOUTHOLD °aye BUILDING DEPARTMENT y TOWN CLERK'S OFFICE "� • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46558 Date: 7/13/2021 Permission is hereby granted to: Lindh, Alexander 282 County Rd Cresskill, NJ 07626 To: construct interior alterations to existing single-family as applied for per SCHD approval. At premises located at: 2175 Pine Neck Rd., Southold SCTM # 473889 Sec/Block/Lot# 70.-5-48 Pursuant to application dated 3/8/2021 and approved by the Building Inspector. To expire on 1/12/2023. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $567.20 CO-ALTERATION TO DWELLING $50.00 Total: $617.20 I B . n ector i SO!/r,�ol . 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 o sean.devlin(.U-)town.southold.ny.us Southold,NY 11971-0959 MUM BUILDING DEPARTMENT, TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Alexander Lindh Address: 2175 Pine Neck Rd city:Southold st: NY zip: 11971 Building Permit#: 46558 Section: 70 Block: 5 Lot: 48 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Hubbard Electric License No: 4709ME SITE DETAILS Office Use Only Residential X Indoor Basement X Service X Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor X Hot Tub Addition Survey Attic X Garage INVENTORY Service 1 ph Heat Duplec Recpt 57 Ceiling Fixtures 16 Bath Exhaust Fan 3 Service 3 ph Hot Water Gas GFCI Recpt 5 Wall Fixtures 6 Smoke Detectors 5 Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures 27 CO2 Detectors Sub Panel A/C Blower 2 Range Recpt Gas Ceiling Fan Combo Smoke/CO 3 Transformer UC Lights 5' Dryer Recpt 30A Emergency Fixtures Time Clocks Disconnect 3 Switches 32 4'LED Exit Fixtures 11 Pump Other Equipment: Fridge, Oven, DW, Hood, Micro, W/D, Mini Fridge, Insinkerator, Toe Kick Heater, Smart Toilet, 200A Panel Notes: Whole House Renovation and New Septic System Inspector Signature: Date: December 15, 2021 S.Devlin-Cert Electrical Compliance Form x,of so�ryQlo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 • Southold,NY 11971-0959 Q BUILDING DEPARTMENT -,1 TOWN OF SOUTHOLD �`� ' C NO CERTIFICATION Date: Jc o2 Building Permit No. J O Owner: NQ-} L--,Yx X (Please print) Plumber: N orlon 7(Unn�,rL —ENA Fo neape� (Please print) I certify that the solder used in the water supply system contains less than 2/10 of I% lead. (Plumbers Signature) Sworn to before me this day of FAfU\0V , 20 a ) CONNIE D.BUNCH I Notary Public,State of New York No.01 BU6185050 Qualified in Suffolk County Commission Expires April 14, p Notary Public, County ,OF SOUly06 q 055 # # 'TOWN-OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY-INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: E6 "C2 DATEINSPECTOR Lf OF SOUTyO� �6 • ,, Tt �� # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION- 7[ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING' [ ] FRAMING /STRAPPING [ ' ] FINAL ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [L] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE ✓� �f INSPECTOR * # TOWN OF SOUTHOLD-BUILDING"DEPT.- cou765.1802 1_N-SPECT- ON [ ] FOUNDATION 1ST [ R GH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING, [ ] FRAMING /STRAPPING [ ] FINAL ] FIREPLACE 4 CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] -FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) , [ ] ELECTRICAL (FINAL) [ ] CODE VIOLAATION [ ] PR49441 E C/O REMARKS: `U D. �( �k w e, vc� vh IS P` VlV S�D?i � S ✓' i �qjt.'t'fd AN/ (pAv h �vY v4wi V i . DATE 22 INSPECTOR ` OE 50UTy�l - # TOWN -OF SOUTHOLD BUILDING DEPT: °`ycouto, 765.1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. j ] FOUNDATION 2ND [ ] INSULATION/CAULKING' [ `] FRAMING /STRAPPING [FINAL �I'VTS [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: lvir -coqk �A-61,1 R _ Vv% - DATE Ifiv OF 50 6 5 S # # TOWN OF SOU_ THOLD BUILDING DEPT. •°`yio - courm��'' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND- [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETYINSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: :.I DATE INSPECTOR oF souryo ti !0 11 .e #. # TOWN OF SOUTHOLD BUILDING DEPT.- 765-1802 EPT.765.1802 INSPECTION [' ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [' ]: INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL ['" ] FIREPLACE &.CHIMNEY [ ] FIRE SAFETY INSPECTION . [ ]. FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C REMARKS: /OR 4el a-A-- el' &!C jAl A01 b0l 1 /tyeti ,-J DATE Z i,Z- INSPECTOR OF SO(/l�o� f # TOWN OF SOUTHOLD BUILDING DEPT. �yco 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND VSLPAULKINGU FRAMING /STRAPPING' NAL [' ] FIREPLACE & CHIMNEY [ ] .FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O p W REMARKS: _ a� C41 • . Qq D� jr - tip) m/ �fAR-- -& DATE . 3131012-R2-"2- INSPECTOR # f TOWN OF SOUTHOLD BUILDING DEPT.= . 765-1802 INSPECTION = : [ ] FOUNDATION 1ST [ ] ROUGH PL13G. FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL z [ ] FIREPLACE-,& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ '] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE _. INSPECTOR . DAVID TURNER ARCHITECT, P. C . 2-4-22 Southold Department of Buildings Town Hall Annex Building 54375 Route 25 PO Box 1179 Southold, New York 11971 Re: 2175 Pine Neck Road, Southold CERTIFICATION LETTER The framing is complete and complies with 2020 Residential Building Code. ce ly, avid Turner S�ERED ARS.. 16162Q�a��`c H�TU�'�' \ 1%✓ 2 F-E 450 SEVENTH AVENUE, SUITE 1907 NEW YORK, N.Y. • 10123 PHONE: (212) 594-0840 • FAX: (212) 594-1530 DAVID TURNER ARCHITECT, P. C . 2-4-22 Southold Department of Buildings Town Hall Annex Building 54375 Route 25 PO Box 1179 Southold, New York 11971 Re: 2175 Pine Neck Road, Southold CERTIFICATION LETTER The rough plumbing is complete and complies with 2020 Residential Building Code. S' S' Turner RA 16162 z �T9 h0. 16162 �Ta o=� F _ 450 SEVENTH AVENUE, SUITE 1907 NEW YORK, N.Y. • 10123 PHONE: (212) 594-0840 • FAX: (212) 594-1530 DAVID TURNER ARCHITECT, P. C . 2-7-22 Southold Department of Buildings Town Hall Annex Building 54375 Route 25 PO Box 1179 Southold, New York 11971 Re: 2175 Pine Neck Road, Southold CERTIFICATION LETTER As per the attached diagram. The "red" walls were taken down to the studs as a part of the proposed plan and reinsulated with a minim of R19 batt insulation. S ce ely, avid Turner RA 16162 S'T No. 16162 qTF OF 450 SEVENTH AVENUE, SUITE 1907 NEW YORK, N.Y. 10123 PHONE: (212) 594-0840 • FAX: (212) 594-1530 DAVID TURNER ARCHITECT, P. C . 2-11-22 APR .1 4 2022 Southold Department of Buildings BUILDING DEPT. Town Hall Annex Building TOWN OF SOUTHOLD 54375 Route 25 PO Box 1179 Southold,New York 11971 Re: 2175 Pine Neck Road, Southold CERTIFICATION LETTER All new concrete footings supporting the newly installed lally columns in basement are complete and comply with 2020 Residential Building Code. !avid rel , Turner RA 16162 5 xi ^t T dor 16162 450 SEVENTH AVENUE, SUITE 1907 - NEW YORK, N.Y. - 10123 PHONE: (212) 594-0840 - FAX: (212) 594-1530 Li APR) 4 2022 B, & BUILDING DEPT TOWN OF SOUTHOLD Testing and Balancing AIR BALANCING WATER BALANCING DESIGN ANALYSIS DUCT PRESSURE TESTING BLOWER DOOR TESTING AEROSEAL DUCT SEALING DUCT LEAKAGE TEST REPORT PROJECT 2175 Pine Neck Rd Southold, NY 11971 PREPARED FOR Alex Lindh a.lindhl@gmail.com DATE TESTED : 4/12/2022 SUBMITTED BY: MP PREPARED BY: JO REPORT DATE: 4/12/2022 l B&L Testing and Balancing INSTRUMENT LIST FUNCTION MAKE MODEL NO. SERIAL NO. CALIBRATION DATE Manometer Gauge Retrotec DM32 20A 414417 2/7/2022 PROJECT SUMMARY B&L Testing and Balancing visited the home located at 2175 Pine Neck Rd on 4/12/22 to perform duct leakage testing on two (2) distinct duct systems located outside of the thermal envelope. All tests were performed post-construction. Results have been tabulated in the pages below and are certified accurate and in compliance with NYS Energy Conservation Code 2020. B&L Testing and Balancing 2735 Academy Street Oceanside,NY 11572 Page 2 of 5 (516) 724-3630 B&L Testing and Balancing Project: 2175 Pine Neck Rd Date Tested: 4/12/2022 Maximum Total Test Allowable Actual Total Complies Unit /Area Floor Area Pressure Leakage Allowable Leakage with NYECC Served Served (Sgft) (inches w.c.) Rate �CFM)e (CFM) 2020 (cfin/100 fe) Living Room/1 500 0.1 4 20 Yes Dining Room 119.9 0.1 4 5 Yes Bathroom 77.51 0.1 4 3 Yes Office 157 0.1 4 6 Yes Back Hallway 19 0.1 4 1 Yes Entrance way 118 0.1 4 5 Yes Stairwell 41 0.1 4 1 2 1 1 Yes Total 1 41 30 Yes B&L Testing and Balancing 2735 Academy Street Oceanside,NY 11572 Page 3 of 5 (516) 724-3630 • B&L Testing and Balancing Project: 2175 Pine Neck Rd Date Tested: 4/12/2022 Maximum Test Allowable Total Actual Total Complies Unit /Area Floor Area Allowable Served Served (Sgft) Pressure Leakage Leakage Leakage with NYECC (inches w.c.) Rate (CFM) (CFM) 2020 (cfm/100 fe) Hallway 170 0.1 4 7 Yes Hallway Bathro 61 0.1 4 2 Yes Back single Bed 143 0.1 4 6 Yes Bedroom with 1 156 0.1 4 6 Yes Bathroom in Be67 0.1 4 3 Yes Second Bedrooi 150 0.1 4 6 Yes 1st Bedroom to 155 0.1 4 6 Yes Total 36 32 Yes B&L Testing and Balancing 2735 Academy Street Oceanside,NY 11572 Page 4 of 5 (516) 724-3630 B&L Testing and Balancing CALIBRATION CERTIFICATE Certificate of Gauge Calibration Issued by:Retrotec Certificate Number:414417 041907 Calibration Date:2022-02-07 Results:As Left 1060 E Pole Rd. Everson,WA,USA 98247 "I"t a" AC-1943 T•+1(360)738-9835 This calibration laboratory has been assessed by the ANSI- ASQ National Accreditation Board and meets the E:calibration@retrotec.com W:www.retrotec.com requirements of international standardlSO/IEC 17025. Instrument: Description: Pressure and Flow Gauge Calibrated by:Tina Lukyanets Manufacturer: Retrotec Model Number: DM32 20A Serial Number: 414417 Signature Issue Date:2022-02-07 Environmental conditions: Temperature: 68°F±10°F Relative Humidity: 50%±30% Mains Voltage: 120V±10V Mains Frequency: 6011z±1Hz Comments: Results recorded as received.No adjustment performed. This calibration applies only to the unit listed on this certificate. Calibration Information: The Device was calibrated against laboratory standards whose values are traceable to recognized national standards.The uncertainty represents an expanded uncertainty using a coverage factor of k=2 to approximate a 95%confidence level.In tolerance conditions are based on test results falling within specified limits without taking uncertainty into account.The uncertainty evaluation has been carried out in accordance with ISO/IEC 17025 requirements. Calibration Procedure: CP-35-01 This Calibration Certificate shall not be reproduced except in full,without written approval from Retrotec. B&L Testing and Balancing 2735 Academy Street Oceanside,NY 11572 Page 5 of 5 (516) 724-3630 FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION(IST) ?may y ------------------------------------ . C FOUNDATION(2ND) • z �o ROUGH FRAMING& y PLUMBING ,e r INSULATION PER N.Y. y STATE-ENERGY CODE CL glm.k Ab Yti► 0%,11 lei c �r.Gl FINAL. �k 9 6f ADDITIONAL COMMENTS 16 2( 4q-, 5 �.� n I a. �� r � re a 1 O 1J.-1 • a•.1 l ec 'ri C.. C,e , y' rb rn +nom _ 4Ok N �a �5 -� ► �- - N 74 9-X4 a rec.� al BO-H (dh Ib NOV 0 .3 2021 SVFfO�� BUI21G DEPARTMENT:-Electrical Inspector BUILDING DEPT , ayO� COGy TOWN OF SOUTHOLD TOWN OF SOUTHOLD o Town,Hall Annex- 54375 Main Road - PO Box 1179 wMi. Southold,'New York 11971-0959 Telephone (631).765-1802 - FAX (631) 765-9502 1 rogerr(7.southoldtownny.aov- sea ndCD-'southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 11/1/21 Company Name: Peconic Bay Electric Corp. Electrician's Name: Jose Umana License No.: ME-46360 Elec. email:pecbayelec@gmail.com Elec. Phone No: 631-987-4406 01 request an email copy of Certificate of Compliance Elec. Address.: 218 Oak Ave, Flanders, NY 11901 JOB SITE INFORMATION (All Information Required) Name: Alexander Lindh Address: 2175 Pine Neck Rd, Southold, NY 11971 Cross Street: Oaklawn Ave Phone No.: 845-775-7266 ' Bldg.Permit M 46558 ernail:alindhl@g'mail.com Tax Map District: 1000 Section:70 Block: 5 Lot:48 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Whole house rewiring and service upgrade Square Footage: Mom Circle All That Apply: Is job ready for inspection?: p YES[V�NO [_�Rough In 0 Final Do you need a Temp Certificate?: YES❑,NO Issued Temp Information: (All information required) Service SizeFV11 Php3 Ph Size: 200 A #Meters 1 Old Meter# 098367658 ':D New Service Fire ReconnectE]Flood Reconnect[]✓„Service-Reconnect OUnderground QOverhead #Underground Laterals R 1 n2 0 H Frame El Pole Work done on Service? M Y RN Additional Information: Upgrading the service from 100A to 200A PAYMENT DUE WITH APPLICATION 053 P PERMIT# R}pr Address: s- Switches Outlets V4 AA w � GF I's Surface Sconces. . .. HH's UCLts _ Fans . ,. >.,.•..�. ,. ...:F"ridge..',,: .�.... ... .... .. _ __.., ._ HW ... f I Exhaust I 1 1� Oven Gf� W/D: ' Smokes DW Mini Carbon Micro:: _ Gene`rator Combo _.: .._ Co.oktop :;,. .. AC. c AH Hood .:..fi° Service Have Amps se Special: : . G,�.. ,:... . ....: . . • Comments: C )�,Oell - 45�-"160. ,,� Ch V.G ._. - OFFOdK�oG BUILDING DEPARTMENT-Electrical Inspector H x TOWN OF SOUTHOLD o • Town Hall Annex-54375 Main Road-PO Box 1179-Southold, NY 11971-0959 y 9 �` Telephone(631) 765-1802-FAX(631) 765-9502 Temporary Certificate #j 112 tt Date t4ovemkc_4 , 2021 Customer NameAlcy L j ndh Electrician Name Address rj Pine NrC'V,'M, o Phone _ e-mail al i e-mail Phone 16 Lf j— S-- License# — Size DO A Phase I Overhead X Underground #of Meters Remarks #of Underground LateralsLH 2 New "H" Frame or Pole P Fire Reconnect Was work done on Service? Y Flood Reconnect Old Meter# ® (o*j Service Reconnected Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this installation is complete,the town will conduct a,premises inspection of the service equipment. This verification is valid days from the d above. Authorized by y 00, LOAMY SAND(5M) 4 6 EL.8.0' i 1T5A0' —�� — — EL.'1.0' \ ` 50", TG5T HOL2 MIXED SAND KITH GRAVEL(SP) GRAVC-L DRIVE NO GROUND'NATER ENCOUNTERED I GG550R'� 1 E TO 17 FEET BELOW GRADE TOt "CO, •AtER ,�, BORING TEST HOLE T k� BAR L.9.0' II1 1 G� -- ---........_...__ 5HANN M BARRON M.S..- 1. 124 PLEASURE DRIVE ✓ !GO RIVERHEAD,NY 11901 5aR =STOR u� ``•-t�,1 �___ z y--��" o TAX`4AP:1000 5E07I0N.70 �_ i;, _� 11, •s BLOCK,5 2� '' :�- F.F EL,10.0' X000 psGKL07 ,I1 LOT SIZE, 1"1,126.36 5O FT 12'Cl Oy 1 ILIF �', _ 1111 r ` POOL TOTAL BUILDING LOT Y I $ G Qpi+Rt' N` ��- �N / 8'��-+""© GOVERAGE� 2115' ALL ADJAG=NT LOTS ARE DEVELOPED KITH NO `` J USE OF WELL PLATER y� \` 1`, EL.b.0' WATER SUPPLIED BY MUNICIPALITY PLOT PLAN \ LEGEND 1 ._..n_._4ry__....,... aurrgg'saa' strm muu be is �• �HYDRO ACTION AN 6,00 �, 03 om mm=P� t S��t 5GA_E I"=20' V. ®POLYLOK D15TRIbUTIGN BOX 0000pkW lamWNM�^/spoof \ atio I \ '•,\ ©b'DIAMETER X b'D'cEP LEACHING PIT l'`0 Hydro Adon I/A OWTS $ ' BLOCK CESSPOOL TO BE ABANDONDED h A \ � © �a� DAVICYTURNERARCHIT,ECT,P.C. ©FUTURE LEACHING PIT(SG%EXPANSION) 3509EVENM AVENUE.SUITE 1907,NEWA'ORX,N.Y.70783 SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES '1, (212)694.0810 FAX1212)599$500 PERMIT FOR APPROVAL OF CONSTRUCTION FOR A OAKL\AI'VN AVE'`- '��� SEWAGE&LEA6HING PLAN SINGLE FAMILY RESOENCEAND _ -Ai 2175 PINEz'NECK ROAD o Sedmom Accessory Garage \ , SOUFHOLD,N.Y. DATE 7/8/21 H.S.REF.No. R-21-1244 CERTIIICATIdN\EQLIRE0. 11 SSEp a cn*c eoo-x� PPROVED SUBMITPOn R.A. CeRTrCC`Al, �� FGy/FPA _cr N' oT P F IN stALITION ANo Cox araucTloay TOTAL MAXIMUM BEDROOMS 6 Or IIA OWTS EXPIRES THREE YEARS FROM DATE OF APPROVAL Faa FmA L ArvRoo l „ ' . �' e .-100.00 q N.16162 unrT ' c I k aI- /a qq 4f(p1558 LOAMY SAND (5M) 8 EL. .0' j / 175.00' _ _ EL. '7.0' 4.6 BORING TEST HOLE MIXED SAND WITH � \ GRAVEL (SP) 17.01 0 , GRAVEL DRIVE NO GROUND WATER ENCOUNTERED �`�� �GGSSOi2Y H>= 1, TO 17 FEET BELOW GRADE 50RI NO TEST HOLE EL. 9.0' -�fL S,vR SHAWN M BARRON M.S. I . GONG PAD M0N V,0L1, 124 PLEASURE DRIVE JAG ,��( GO OF RIVERHEAD, NY 11901 �O TAX MAP:1000p PANS F� 5\��NG GO 3 A_74'� 0 I SECTION:70 0 M o , B 40 p 1` BLOCK: 5 F.F EL. 10.0' LOT:45Z O A GO WOO MIN z0' LOT SIZE: 17,126.36 50 FT 5 �?/N TOTAL BUILDING LOT rn P � GON N ��N'C rn�N z 2 A-69 .. 3 pp, COVERAGE: B-38 OVRAGE: 217 � -6 76' 5' z p,R G�55 A2' A- ALL ADJACENT LOTS ARE PIC, ,- 1 5-51' 3 5-46 DEVELOPED WITH NO USE OF WELL WATEREL ` . 7.0' I ` EL. 5.0' , WATER SUPPLIED BY Y MUNIGIPALIT — a FLOT FLAN LEGEND APR ®8 222 SCALE 1" = 20' \ �` QI HYDRO ACTION AN 600 POLYLOK D15TRIBUTION BOX 0 3 � , W'mGo. �� t� O' DIAMETER X 8' DEEP LEACHING PIT , 9 �� DAVIEyTURNER ARCHIT CT P.C. SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES ® BLOCK GE55POOL TO BE ABANDONDED APPROVAL OF CONSTRUCTED WORKS FOR \� O Y� X54 SEVENTH AVENUE,SUITE 1907,NEW Yf RK,N.Y.10123 A SINGLE FAMILY RESIDENCE AND � � �7p (212)594-0840 FAX(212)594-1530 AKLAM AVE -�� ' SEWAGE & LEACHAN PLAN H.S. Ref. No. - - !a �f 2175 PINE NECK ROAD Date APR 2 2022 13c_ _- The aewaga dianasal and water supply facilities at this Iavvtion have beenSOUTHQLD, N.Y. InWedcd andtor certified try t#Department or other agencies and found to _ _ � :r.m-�<� be ea§*ctWv FO'R TOTALMAXlIrVIUM OF.'_ BEDROOMS. �, ! C f r. ��I C���\V I i. Tv %� DATE: 3-25-22 6-4-21 PROJECT No: DT } PR 2 6 2022 II'� DRAWING BY: -...., -. -1.... '_ v CHK BY: R F Chief `� B ILDING DEPT. �r TOW OF SOUTHOLD ?' DWG No: ` IA- 100.01 . . -------- �`+`.. FfI J CAD FILE No: O�O LEOENL;) E----D REMOVALS AND DEMOLITIONS ❑❑ - ® NEW NON-RATED PARTITIONS BD DINING ROOM BEDROOM BEDROOM O SMOKE/CARBON MONOXIDE DETECTOR m � >< Lo 8'-7 I S'-7'• LIVING ROOM ° DAVID TURNER ARCHITECT, P.C. m - �S'� BEDROOM BEDROOM DEN 450 SEVENTH AVENUE, SUITE 1907, NEW YORK,N.Y. 10123 UP - (212)594-0840 FAX(212)594-1530 12' PROJECT 2175 PINE NECK ROAD m SOUTHOLD, N.Y. Fl Ej SHEET z. - PROPOSED PLANS SES' DATE: 3-5-21 PROJECT No: TR I y DRAWING BY: FROFOaQ;) FIRST FLOOR FROFOSEE�) SECOND FLOOR ' =- CHK BY: DWG No: ti /VO. 1a6162 / \ 102 . 00 F CAD FILE No: 3 OF 3 LM i f r v AP ROVED AS N TED ,ALL PL1lMI �� WA ..; DATE: $ WATER:LINES NEED B.P.- # T� NGE COVERING FEE;;, B1` W NOTIFY;BUILDING 'hRTMEN AT . 766=1802:` 8'AM TO +PM FOR THE FOLLOWING,.INSPECTIONS: i.-POUND'' ..FOUNDATION = TWO REQUIRED .FOR-POURED CONCRETE 2. ROUGH,-;FRAMING & PLUMBING 3 INSULATION ELECTRICAL 4: FINAL - :CONSTRUIC',ON MUST BE COMPLETE FO-; aoINSPECTIONINSPECTION REQUIRE® . ALL,,CONSTRUCTIOIN SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF J' !^ OARD i �i��MTEES OCCUPANCY OR USE IS'UNLAWFUe WITHOUT CERTIFICAT` OF OCCUPANCY KUMEER CERT (CATION ON LEO-00I1 j ENT BEFORE CERTIFICA,rE,OF bCCUPANC, SOLDERVSEDIN WATER SUPPL Y S;YSTEII4 CAN,.NOT EXCEED 2110 OF 1%-LEAD i TAX LOT 401.4 D� SCOPE OF WORK DRAWING INDEX TAX LOT 54.' MOD I F I GAT I ON TO PARTI TI ONS AND NEW BATHROOM A-100.00 PLOT PLAN AND NOTES A-101.00 DEMOL I T I ON PLANS TAX LOT 48 A-102.00 PROPOSED PLANS A-105.00 STRUCTURAL AND FOUNDATION PLAN TAX ----- ------- LOT LAITLAV LAV 48 W/G yvr- 54iG'/'�R SFIOWER 2ND Floor i W i NEW FIXTURES ON EXIST ROUGHING 5111K LAV K, ; f 2 K W/G ' `� MAR 8 2021 vilz GROUND Floor 5`flsrN i ''`-`.,•.;V•, rY,., x`;• `..;01.,.'-"�''i NEN FI TAX LOT 47 30 Q ON EXI5TURES R000HIN& EXIST VENT RISER - ,4 199.10' h EXIST WASTE STAG1L I PLUMBING RISER DIAGRAM DAVID TURNER ARCHITECT, P.C. AGE of PAM�NT NOT TO 5GALE ° 450 SEVENTH AVENUE,SUITE 1907, NEW YORK,N.Y. 10123 G✓ �O�� _ (212)594-0840 FAX(212)594-1530 PROJECT 2175 PINE NECK ROAD TAX MAF: 1000 SOUTHOLD, N.Y. PLOT PLAN 5EGTION:70 BLOG{G: 5 SHEET I LOT:45 PLOT PLAN SCOPE OF WORK TABLE OF AREAS: LOT SIZE: 17,126.5& SQ FT SEAL DATE: $_5-21 = D PROJECT No: TR E X I ST N G TOTAL BUILDING COVERAGE_: 2175 DRAWING BY: ] CHK BY: PROPOSED BUILDING EXTENSION COVERAGE: — * r 'L' �/' * DWG No: EXISTING TOTAL LOT GO\IERAGE=: sT.�TFO1s162 A- 1 00 . 00 F CAD FILE No: 3 OF 3 L EOEND REMOVALS AND DEMOL I TI ON5 ® NEW NON—RATED PARTITIONS DINING ROOM BEDROOM BEDROOM , t� cV = Q SMOKE/CARBON M NOXIDE DETECTOR 6—2 dn e�a 0 ® f_ LIVING ROOM 3 0 DAVID TURNER ARCHITECT, P.C. FAMILY ROOM BEDROOM g_q BEDROOM ; 450 SEVENTH AVENUE,SUITE 1907, NEW YORK, N.Y.10123 (212)594-0840 FAX(212)594-1530 12' PROJECT 2175 PINE NECK ROAD m SOUTHOLD, N.Y. SHEET PROPOSED PLANS a ,a SEAL AND E DATE: 3-5-21 !`GAS.-cQ HDrURy�j� PROJECT No: TR 41 PROPOSED FIRST FLOOR Py y tiF�°� G BY: PROPOSED SECOND FLOOR o D CHK BY: Rj DWG No: = _ A- 102 . 00 `��' 'vD• 16162 9TFOF CAD FILE No: 3 OF 3 LEGEND I II II I II II II I II II it ' i II II ii REMOVALS AND DEMOLITIONS IIIII I I I I { I ® NEW NON-RATED PARTITIONS I SMOKE/CARBON MONOXIDE DETECTOR III I H---- i I ----� I II II II I u L------------- I 1 I �J II ------ ---------1---� • II I L_ _j I I I I I I po'I i nI ==YI==u `� II ll \ IF I I - DAVID TURNER ARCHITECT, P.C. I I -`Z•-_-J --� f 450 SEVENTH AVENUE,SUITE 1907, NEW YORK, N.Y. 10123 (212)594-0840 FAX(212)594-1530 II PROJECT --�' 2175 PINE NECK ROAD II \. SOUTHOLD, N.Y. SHEET DEMOLITION PLANS I SEA DATE: 3-5-21 X- '��p H. rV�iy �O� PROJECT No: TR FROPOSED SECOND EMOLITIONFI �ST FLOOR DEMOLITION , G BY: CHK BY: P A _ * DWG No: A- 1 01 . 00 b �q °• 1616 TF OF CAD FILE No: 30F3 4 " C OLUININ 4II LALL"'r GOLUJ -IN K TH 1211 X 12 " X 2 PLATE LEGEND REMOVAL5 AND DEMOL I TI ON5 ® NEW NON-RATED PARTITIONS lelIOXI � I_ O 5MOKE/CARB0N MONOXIDE DETECTOR I � I I NEJM C..ONr-,RETE 24" FOUNDATION FOR LAL L1" II --------- Cl -------- -�- 1 ❑ ,OLUI` fNS TO EXTENT C ------) le� II------ _T I�� II � LSO V ORAE COLUMN I I i COLUMN DAVID TURNER ARCHITECT, P.C. 450 SEVENTH AVENUE,SUITE 1907,NEW YORK, N.Y. 10123 I (212)594-0840 FAX(212)594-1530 d PROJECT 2175 PINE NECK ROAD SOUTHOLD, N.Y. SHEET t r STRUCTURAL AND FOUNDATION PLANS SEAL AN Rc DATE: 3-5-21 I•— PROJECT No: TR FIRST FLOOR SUPPORT PLAN FOUNDATION PLAN � DRAWING BY: F> �Vii;.� d} C_ s CHK BY: # * * DWG No: Ij Q4~ A- 1 03 . 00 �qT��• 16162 a OF CAD FILE No: 30F3 f t