HomeMy WebLinkAboutStructural Analysis Report RECEIVED JUN 2 4 2022 S t of Town CROWN Date: April 11,2022 Planning Board CC CASTLE Crown Castle 2000 Corporate Drive Canonsburg, PA 15317 (724)416-2000 Subject: Structural Analysis Report Carrier Designation: DISH Network Co-Locate Site Number: NYNYCO2191A Site Name: NY-CCI-T-843211 Crown Castle Designation: BU Number: 843211 Site Name: MATTITUCK JDE Job Number: 640434 Work Order Number: 2081886 Order Number: 549093 Rev. 2 Engineering Firm Designation: Crown Castle Project Number: 2081886 Site Data: ELIJAH'S LANE, MATTITUCK,SUFFOLK County, NY Latitude 400 59'57.79", Longitude-72°30'40.17" 107.5 Foot-Monopole Tower Crown Castle is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above-mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC7: Proposed Equipment Configuration Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 128 mph as required by the 2020 New York State Uniform Code.Applicable Standard references and design criteria are listed in Section 2-"Analysis Criteria". Structural analysis prepared by: Jared Koski, EI Respectfully submitted by: Digitally OF�oNN oN Io ?4 signed by Rohit Soni, P.E. Rohit Soni Senior Project Engineer m Date: _..2022_.04:1:;1 103459 �li� 1`^ _. �O/=ESSIONP� 16:52:54 ` -04'00' tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2)ANALYSIS CRITERIA Table 1 -Proposed Equipment Configuration Table 2-Other Considered Equipment 3)ANALYSIS PROCEDURE Table 3-Documents Provided 3.1)Analysis Method 3.2)Assumptions 4)ANALYSIS RESULTS Table 4-Section Capacity(Summary) Table 5-Tower Component Stresses vs. Capacity- LC7 4.1) Recommendations 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7)APPENDIX C Additional Calculations tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 3 1) INTRODUCTION This tower is a 107.5 ft Monopole tower designed by Summit. The tower has been modified in the past to accommodate additional loading. 2)ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: II Wind Speed: 128 mph Exposure Category: C Topographic Factor: 1 Ice Thickness: 1 in Wind Speed with Ice: 50 mph Service Wind Speed: 60 mph Table 1 -Proposed Equipment Configuration Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size(in) (ft) 3 I jma wireless IMX08FRO665-21 w/Mount Pipe 3 fujitsu I TA08025-13604 88.0 88.0 F---3-7 fujitsu I TA08025-13605 1 1-3/8 1 raycap I RDIDC-9181-PF-48 F-1-1 tower mounts Commscope MC-PK8-DSH Table 2-Other Considered Equipment Center Number Number Feed Mounting Lineof Antenna Antenna Model of Feed Line Level(ft) Elevation Antennas Manufacturer Lines Size (in) (ft) I 6 I alcatel lucent I 80OMHZ 2X50W RRH 108.0 1 3 commscope DT465B-2XR-V2 3 rfs celwave APXVSPP18-C-A20 107.0 4 1-1/4 3 alcatel lucent 190OMHZ RRH (65MHZ) 107.0 3 nokia FZHN 1 tower mounts Platform Mount[LP 301-1] 3 alcatel lucent B25 RRH4X30 99.0 3 nokia AHLBA 3 nokia BAND 5 AHCA RRH4X40 4 3/8 98 0 3 alcatel lucent RRH4X25-WCS 2 3/ /8 9 commscope NNHH-65A-R4 w/Mount Pipe 12 1-5/8 98.0 F 2 --T raycap DC6-48-60-18-8F 1 Conduit F- 1 tower mounts Platform Mount [LP 1201-1 HR-11 2 css X7CAP-FRO-440-VRO 4 css X7CQAP-465-VRO 78.0 78.0 3 raycap RXXDC-3315-PF-48 12 3 1--1/1/ 4 3 samsung RFV01U-D1A telecommunications tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 4 Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line (ft) Level (ft) Elevation. Antennas Manufacturer Lines Size(in) 3 samsungI RFV01 U-D2A telecommunications 1 tower mounts Platform Mount [LP 301-1_KCKR] 3 ericsson RRUS 11 B2 62.0 3 remec S20057A1 3 ericsson ERICSSON AIR 21 134A B2P w/Mount Pipe 6 7/8 61.0 61.0 3 ericsson RADIO 4449 1312/1371 2 1-5/8 3 rfs celwave APXVAARR24_43-U-NA20 w/Mount Pipe 1 tower mounts T-Arm Mount[TA 702-3] 3)ANALYSIS PROCEDURE Table 3 -Documents Provided Document Reference Source 4-GEOTECHNICAL REPORTS I 4840866 I CCISITES 4-TOWER FOUNDATION DRAWINGS/DESIGN/SPECS 4840859 CCISITES 4-TOWER MANUFACTURER DRAWINGS 4840867 CCISITES 3.1) Analysis Method tnxTower(version 8.1.1.0), a commercially available analysis software package,was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A.When applicable, Crown Castle has calculated and provided the effective area for panel antennas using approved methods following the intent of the TIA-222 standard. tnxTower was used to determine the loads on the modified structure.Additional calculations were performed to determine the stresses in the pole and in the reinforcing elements.These calculations are included in Appendix C. 3.2) Assumptions 1) Tower and structures were maintained in accordance with the TIA-222 Standard. 2) The configuration of antennas,transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Crown Castle should be notified to determine the effect on the structural integrity of the tower. tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 5 4)ANALYSIS RESULTS Table 4-Section Capacity(Summary) Section Elevation(ft) Component Type Size Critical Element =Capacity Pass I Fail No. L1 l 107.5-1025. 1 Pole TP24.801x24x0.2188 Pole 1 4.0% I Pass L2 102.5-97.5 Pole TP25.602x24.801x0.2188 Pole 8.7% Pass L3 97.5-92.5 Pole TP26.403x25.602x0.2188 Pole 16.2% Pass r L4 92.5-87.5 Pole TP27.203x26.403x0.2188 Pole 23.9% Pass L5 87.5-82.5 Pole TP28.004x27.203x0.2188 Pole 33.0% Pass L6 82.5-77.5 Pole TP28.805x28.004x0.2188 Pole 42.2% Pass L7 77.5-71.75 Pole TP29.726x28.805x0.2188 Pole 46.6% Pass L8 71.75-70.5 Pole TP29.489x28.688x0.25 Pole 49.0% Pass L9 70.5-65.5 Pole TP30.289x29.489x0.25 Pole 57.3% Pass L10 65.5-60.5 Pole TP31.09x30.289x0.25 Pole 65.3% Pass 1-11 60.5-55.5 Pole TP31.891x31.090.25 Pole 73.6% Pass L12 55.5-53.583 Pole TP32.198x31.89lx0.25 Pole 76.6% Pass L13 53.583-53.333 Pole+Reinf. TP32.238x32.198x0.4125 Reinf.2 Tension Rupture 63.4% Pass 1 L14 153.333-48.333 Pole+Reinf. I TP33.039x32.238x0.4125 Reinf.2 Tension Rupture 69.8% Pass L15 48.333-43.333 Pole+Reinf. I TP33.84x33.039x0.4063 Reinf.2 Tension Rupture 75.9% T Pass L16 43.333-35.5 Pole+Reinf. TP35.094x33.84x0.4063 Reinf.2 Tension Rupture 79.7% Pass L17 35.5-35 Pole TP34.674x33.873x0.3125 Pole 73.5% Pass L18 35-30 Pole TP35.475x34.674x0.3125 Pole 77.6% Pass L19 I 30-27.75 I Pole TP35.835x35.475x0.3125 Pole 79.4% Pass L20 27.75-27.5 Pole+Reinf. TP35.875x35.835x0.5125 Reinf.1 Tension Rupture 69.4% Pass L21 27.5-22.5 Pole+Reinf. TP36.676x35.875x0.5125 Reinf.1 Tension Rupture 72.9% Pass L22 22.5-17.5 Pole+Reinf. TP37.477x36.676x0.5 Reinf.1 Tension Rupture 76.2% Pass L23 17.5-12.5 Pole+Reinf. TP38.278x37.477x0.5 Reinf.1 Tension Rupture 79.3% Pass L24 12.5-7.5 Pole+Reinf. TP39.079x38.278x0.4938 Reinf.1 Tension Rupture 82.2% Pass L25 7.5-2.5 Pole+Reinf. TP39.88x39.079x0.4875 Reinf.1 Tension Rupture 84.9% Pass L26 2.5-0 Pole+Reinf. TP40.28x39.88x0.4875 Reinf.1 Tension Rupture 86.2% Pass Summary l I I Pole 79.4% Pass Reinforcement 86.2% Pass Overall 86.2% Pass tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 6 Table 5-Tower Component Stresses vs. Capacity-LC7 Notes Component Elevation (ft) % Capacity Pass/Fail 1 I Anchor Rods I 0 I 73.4 I Pass 1 Base Plate 0 80.8 Pass 1 Base Foundation (Structure) 0 75.7 Pass 1 Base Foundation (Soil Interaction) 0 83.2 Pass Structure Rating (max from all components)= 86.2% Notes: 1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity consumed. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 7 APPENDIX A TNXTOWER OUTPUT tnxTower Report-version 8.1.1.0 107.5 ft , S o MATERIAL STRENGTH o GRADE Fy Fu GRADE Fy Fu 102.5 ft A607-60 60 ksi 75 ksi A607-65 165 ksi 180 ksi \o o w O N N 97.5 ft TOWER DESIGN NOTES o N 1. Tower is located in Suffolk County,New York. N2. Tower designed for Exposure C to the TIA-222-H Standard. 3. Tower designed for a 128 mph basic wind in accordance with the TIA-222-H Standard. 92.5 ft 4. Tower is also designed for a 50 mph basic wind with 1.00 in ice.Ice is considered to increase o a in thickness with height. 5. Deflections are based upon a 60 mph wind. 87.5 ft 6. Tower Risk Category II. N 7. Topographic Category 1 with Crest Height of 0.0000 ft S o 0 8. TOWER RATING:86.2% N O N N 82.5 ft O m O I O O N p ib C 77.5 ft h O N KI Li N N N o O1 tO 71.8 ft 70.5 ft ooo cbc 0 o m m N < v N < O N G � M 65.5 ft N 24 O O aD N W V O 60.5 ft 0 0 N O y y 55.5 ft m N pJ 53.6 ft V G C O M 48,3 ft n ,n O 00 M W N G 43.3ft m O O N < h N a 35.5 ft aD p BG O O N G 30.0 ft t8 27'8 ft ALL REACTIONS a. ARE FACTORED N O A G 22.5 ft AXIAL 55 K D V 0 17.5 ft SHEAR MOMENT < 6 K 524 kip-ft o I O O N 12.5 ft TORQUE 0 kip-ft 50 mph WIND-1.0000 in ICE o m v N o R < N N c 7.5 ftAXIAL - 37K N o o o m 2.6 ft SHEA MOMENT N e 28 K 2245 kip-ft m N 0.0 ft TORQUE 1 kip-ft -� t REACTIONS-128 mph WIND N C 01 E U Y m d Crown Castle ob:BU#843211 CROWN 2000 Corporate Drive Project: ,.,CASTLE Canonsburg, PA 15317 Client:Crown Castle Drawn by:3Koski N'P'd: The Pathway to Possible Phone:(724)416-2000 code. TIA-222-H Date:02/17/22 Scale: NTS FAy.\: Path: Dwg No.E_1 \ ki \W W 11\W020010B8-SA1Po0BC3 it April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 8 Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-H standard. The following design criteria apply: 1) Tower is located in Suffolk County, New York. 2) Tower base elevation above sea level: 29.0000 ft. 3) Basic wind speed of 128 mph. 4) Risk Category II. 5) Exposure Category C. 6) Simplified Topographic Factor Procedure for wind speed-up calculations is used. 7) Topographic Category: 1. 8) Crest Height: 0.0000 ft. 9) Nominal ice thickness of 1.0000 in. 10) Ice thickness is considered to increase with height. 11) Ice density of 56.00 pcf. 12) A wind speed of 50 mph is used in combination with ice. 13) Temperature drop of 50 °F. 14) Deflections calculated using a wind speed of 60 mph. 15) TOWER RATING: 86.2%. 16) A non-linear(P-delta)analysis was used. 17) Pressures are calculated at each section. 18) Stress ratio used in pole design is 1. 19) Tower analysis based on target reliabilities in accordance with Annex S. 20) Load Modification Factors used: Kes(Fw)= 0.95, Kes(ti)= 0.85. 21) Maximum demand-capacity ratio is: 1.05. 22) Local bending stresses due to climbing loads,feed line supports, and appurtenance mounts are not considered. Options Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments-Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments-Diagonals 4 Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification q Use Clear Spans For Wind Area SR Leg Bolts Resist Compression 4 Use Code Stress Ratios Use Clear Spans For KUr All Leg Panels Have Same Allowable Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice q Bypass Mast Stability Checks Consider Feed Line Torque Always Use Max Kz 4 Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile Project Wind Area of Appurt. Use TIA-222-H Bracing Resist. Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC.6D+W Combination f- Poles Secondary Horizontal Braces Leg q Sort Capacity Reports By Component q Include Shear-Torsion Interaction Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Ignore KUry For 60 Deg.Angle Legs Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are Known Tapered Pole Section Geometry tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 9 Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L1 107.5000- 5.0000 0.00 18 24.0000 24.8008 0.2188 0.8750 A607-60 102.5000 (60 ksi) L2 102.5000- 5.0000 0.00 18 24.8008 25.6017 0.2188 0.8750 A607-60 97.5000 (60 ksi) L3 97.5000- 5.0000 0.00 18 25.6017 26.4025 0.2188 0.8750 A607-60 92.5000 (60 ksi) L4 92.5000- 5.0000 0.00 18 26.4025 27.2034 0.2188 0.8750 A607-60 87.5000 (60 ksi) L5 87.5000- 5.0000 0.00 18 27.2034 28.0042 0.2188 0.8750 A607-60 82.5000 (60 ksi) L6 82.5000- 5.0000 0.00 18 28.0042 28.8050 0.2188 0.8750 A607-60 77.5000 (60 ksi) L7 77.5000- 5.7500 3.75 18 28.8050 29.7260 0.2188 0.8750 A607-60 71.7500 (60 ksi) L8 71.7500- 5.0000 0.00 18 28.6879 29.4886 0.2500 1.0000 A607-60 70.5000 (60 ksi) L9 70.5000- 5.0000 0.00 18 29.4886 30.2894 0.2500 1.0000 A607-60 65.5000 (60 ksi) L10 65.5000- 5.0000 0.00 18 30.2894 31.0902 0.2500 1.0000 A607-60 60.5000 (60 ksi) L11 60.5000- 5.0000 0.00 18 31.0902 31.8909 0.2500 1.0000 A607-60 55.5000 (60 ksi) L12 55.5000- 1.9170 0.00 18 31.8909 32.1979 0.2500 1.0000 A607-60 53.5830 (60 ksi) L13 53.5830- 0.2500 0.00 18 32.1979 32.2380 0.4125 1.6500 A607-60 53.3330 (60 ksi) L14 53.3330- 5.0000 0.00 18 32.2380 33.0388 0.4125 1.6500 A607-60 48.3330 (60 ksi) L15 48.3330- 5.0000 0.00 18 33.0388 33.8395 0.4063 1.6250 A607-60 43.3330 (60 ksi) L16 43.3330- 7.8330 4.50 18 33.8395 35.0940 0.4063 1.6250 A607-60 35.5000 (60 ksi) L17 35.5000- 5.0000 0.00 18 33.8733 34.6741 0.3125 1.2500 A607-65 35.0000 (65 ksi) L18 35.0000- 5.0000 0.00 18 34.6741 35.4750 0.3125 1.2500 A607-65 30.0000 (65 ksi) L19 30.0000- 2.2500 0.00 18 35.4750 35.8354 0.3125 1.2500 A607-65 27.7500 (65 ksi) L20 27.7500- 0.2500 0.00 18 35.8354 35.8754 0.5125 2.0500 A607-65 27.5000 (65 ksi) L21 27.5000- 5.0000 0.00 18 35.8754 36.6762 0.5125 2.0500 A607-65 22.5000 (65 ksi) L22 22.5000- 5.0000 0.00 18 36.6762 37.4771 0.5000 2.0000 A607-65 17.5000 (65 ksi) L23 17.5000- 5.0000 0.00 18 37.4771 38.2779 0.5000 2.0000 A607-65 12.5000 (65 ksi) L24 12.5000- 5.0000 0.00 18 38.2779 39.0787 0.4938 1.9750 A607-65 7.5000 (65 ksi) L25 7.5000-2.5000 5.0000 0.00 18 39.0787 39.8796 0.4875 1.9500 A607-65 (65 ksi) L26 2.5000-0.0000 2.5000 18 39.8796 40.2800 0.4875 1.9500 A607-65 (65 ksi) Tapered Pole Properties Section Tip Dia. Area I r C I/C J lt/Q w w/t in int in4 in in in3 in int in L1 24.3365 16.5116 1179.7676 8.4423 12.1920 96.7657 2361.0876 8.2574 3.8390 17.55 25.1497 17.0677 1303.0131 8.7266 12.5988 103.4234 2607.7408 8.5354 3.9799 18.194 L2 25.1497 17.0677 1303.0131 8.7266 12.5988 103.4234 2607.7408 8.5354 3.9799 18.194 25.9629 17.6237 1434.5563 9.0109 13.0057 110.3025 2871.0002 8.8135 4.1209 18.838 L3 25.9629 17.6237 1434.5563 9.0109 13.0057 110.3025 2871.0002 8.8135 4.1209 18.838 26.7761 18.1797 1574.6673 9.2952 13.4125 117.4032 3151.4066 9.0916 4.2618 19.483 L4 26.7761 18.1797 1574.6673 9.2952 13.4125 117.4032 3151.4066 9.0916 4.2618 19.483 27.5893 18.7357 1723.6168 9.5795 13.8193 124.7253 3449.5016 9.3697 4.4028 20.127 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 10 Section Tip Dia. Area I r C I/C J It/Q w w/t in int in4 in in in3 in" int in L5 27.5893 18.7357 1723.6168 9.5795 13.8193 124.7253 3449.5016 9.3697 4.4028 20.127 28.4025 19.2918 1881.6747 9.8638 14.2261 132.2689 3765.8254 9.6477 4.5437 20.771 L6 28.4025 19.2918 1881.6747 9.8638 14.2261 132.2689 3765.8254 9.6477 4.5437 20.771 29.2157 19.8478 2049.1115 10.1481 14.6330 140.0340 4100.9193 9.9258 4.6847 21.416 L7 29.2157 19.8478 2049.1115 10.1481 14.6330 140.0340 4100.9193 9.9258 4.6847 21.416 30.1508 20.4873 2253.6094 10.4751 15.1008 149.2377 4510.1841 10.2456 4.8468 22.157 L8 29.7017 22.5655 2305.5557 10.0954 14.5734 158.2026 4614.1451 11.2849 4.6091 18.436 29.9050 23.2009 2505.8539 10.3797 14.9802 167.2774 5015.0051 11.6026 4.7500 19 L9 29.9050 23.2009 2505.8539 10.3797 14.9802 167.2774 5015.0051 11.6026 4.7500 19 30.7181 23.8363 2717.4294 10.6640 15.3870 176.6053 5438.4345 11.9204 4.8909 19.564 L10 30.7181 23.8363 2717.4294 10.6640 15.3870 176.6053 5438.4345 11.9204 4.8909 19.564 31.5312 24.4717 2940.5910 10.9483 15.7938 186.1863 5885.0514 12.2382 5.0319 20.127 L11 31.5312 24.4717 2940.5910 10.9483 15.7938 186.1863 5885.0514 12.2382 5.0319 20.127 32.3443 25.1071 3175.6476 11.2325 16.2006 196.0204 6355.4739 12.5559 5.1728 20.691 L12 32.3443 25.1071 3175.6476 11.2325 16.2006 196.0204 6355.4739 12.5559 5.1728 20.691 32.6561 25.3507 3268.9880 11.3415 16.3566 199.8579 6542.2775 12.6778 5.2268 20.907 L13 32.6310 41.6159 5311.9426 11.2838 16.3566 324.7592 10630.874 20.8119 4.9408 11.978 9 32.6717 41.6683 5332.0412 11.2980 16.3769 325.5831 10671.098 20.8381 4.9479 11.995 5 L14 32.6717 41.6683 5332.0412 11.2980 16.3769 325.5831 10671.098 20.8381 4.9479 11.995 5 33.4848 42.7167 5744.7345 11.5823 16.7837 342.2808 11497.028 21.3624 5.0888 12.337 1 L15 33.4858 42.0776 5660.9451 11.5845 16.7837 337.2885 11329.339 21.0428 5.0998 12.553 1 34.2989 43.1101 6087.9954 11.8688 17.1905 354.1493 12184.001 21.5592 5.2408 12.9 5 L16 34.2989 43.1101 6087.9954 11.8688 17.1905 354.1493 12184.001 21.5592 5.2408 12.9 5 35.5727 44.7277 6799.3303 12.3142 17.8278 381.3902 13607.607 22.3681 5.4615 13.444 3 L17 35.0795 33.2881 4736.8725 11.9141 17.2076 275.2773 9479.9779 16.6472 5.4117 17.317 35.1608 34.0825 5084.1261 12.1984 17.6145 288.6336 10174.941 17.0445 5.5526 17.768 9 L18 35.1608 34.0825 5084.1261 12.1984 17.6145 288.6336 10174.941 17.0445 5.5526 17.768 9 35.9740 34.8768 5447.9486 12.4827 18.0213 302.3062 10903.065 17.4417 5.6936 18.22 7 L19 35.9740 34.8768 5447.9486 12.4827 18.0213 302.3062 10903.065 17.4417 5.6936 18.22 7 36.3400 35.2342 5617.1773 12.6106 18.2044 308.5622 11241.745 17.6205 5.7570 18.422 8 L20 36.3091 57.4588 9057.4467 12.5396 18.2044 497.5426 18126.811 28.7349 5.4050 10.546 4 36.3498 57.5239 9088.2842 12.5538 18.2247 498.6794 18188.526 28.7674 5.4121 10.56 9 L21 36.3498 57.5239 9088.2842 12.5538 18.2247 498.6794 18188.526 28.7674 5.4121 10.56 9 37.1630 58.8266 9719.8184 12.8381 18.6315 521.6866 19452.426 29.4189 5.5530 10.835 3 L22 37.1649 57.4117 9492.5862 12.8426 18.6315 509.4905 18997.662 28.7113 5.5750 11.15 9 37.9781 58.6826 10137.058 13.1269 19.0384 532.4546 20287.456 29.3469 5.7160 11.432 9 ' 4 L23 37.9781 58.6826 10137.058 13.1269 19.0384 532.4546 20287.456 29.3469 5.7160 11.432 9 4 38.7913 59.9535 10810.061 13.4112 19.4452 555.9250 21634.346 29.9825 5.8569 11.714 4 9 L24 38.7922 59.2139 10680.234 13.4134 19.4452 549.2485 21374.522 29.6126 5.8679 11.884 7 7 39.6054 60.4690 11373.833 13.6977 19.8520 572.9313 22762.632 30.2402 6.0089 12.17 3 6 L25 39.6064 59.7132 11235.318 13.6999 19.8520 565.9539 22485.421 29.8623 6.0199 12.348 7 1 40.4196 60.9524 11949.391 13.9842 20.2588 589.8363 23914.506 30.4820 6.1608 12.638 7 8 L26 40.4196 60.9524 11949.391 13.9842 20.2588 589.8363 23914.506 30.4820 6.1608 12.638 7 8 40.8262 61.5719 12317.502 14.1263 20.4622 601.9626 24651.213 30.7918 6.2313 12.782 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 11 Section Tip Dia. Area l r C VC J It/Q w w/t in int in° in in in3 in4 int in 7 2 Tower Gusset Gusset Gusset GradeAdjust.Factor Adjust. Weight Mult. Double Angle Double Angle Double Angle Elevation Area Thickness Ar Factor Stitch Bolt Stitch Bolt Stitch Bolt (per face) Ar Spacing Spacing Spacing Diagonals Horizontals Redundants ft ft2 in in in in L1 107.5000- 1 1 1 102.5000 L2 102.5000- 1 1 1 97.5000 L3 97.5000- 1 1 1 92.5000 L4 92.5000- 1 1 1 87.5000 L5 87.5000- 1 1 1 82.5000 L6 82.5000- 1 1 1 77.5000 L7 77.5000- 1 1 1 71.7500 L8 71.7500- 1 1 1 70.5000 L9 70.5000- 1 1 1 65.5000 L10 65.5000- 1 1 1 60.5000 L11 60.5000- 1 1 1 55.5000 L12 55.5000- 1 1 1 53.5830 L13 53.5830- 1 1 1.05915 53.3330 L14 53.3330- 1 1 1.04803 48.3330 L15 48.3330- 1 1 1.05321 43.3330 L16 43.3330- 1 1 1.04633 35.5000 L17 35.5000- 1 1 1 35.0000 L18 35.0000- 1 1 1 30.0000 L19 30.0000- 1 1 1 27.7500 L20 27.7500- 1 1 1.03696 27.5000 L21 27.5000- 1 1 1.0275 22.5000 L22 22.5000- 1 1 1.04355 17.5000 L23 17.5000- 1 1 1.03468 12.5000 L24 12.5000- 1 1 1.039 7.5000 L25 7:5000- 1 1 1.04379 2.5000 L26 2.5000- 1 1 1.03974 0.0000 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Exclude Componen Placement Total Number Start/En Width or Perimete Weight From t Number Per Row d Diamete r Torque Type ft Position r plf Calculation in in tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 12 Description Sector Exclude Componen Placement Total Number StartlEn Width or Perimete Weight From t Number Per Row d Diamete r Torque Type It Position r plf Calculation in in *** HCS 6X12 4AWG(1- A No Surface Ar 61.0000- 2 2 0.100 1.6600 2.40 5/8) (CaAa) 0.0000 0.180 LCF78-50JA(7/8) A No Surface Ar 61.0000- 6 6 0.180 1.0900 0.32 (CaAa) 0.0000 0.310 ***mods*** (Area)CCI-65FP- A No Surface Af 30.5000- 1 1 0.000 6.5000 15.5000 0.00 065125(H) (CaAa) 0.0000 0.000 (Area)CCI-65FP- B No Surface Af 30.5000- 1 1 0.000 6.5000 15.5000 0.00 065125(H) (CaAa) 0.0000 0.000 (Area)CCI-65FP- C No Surface Af 30.5000- 1 1 0.000 6.5000 15.5000 0.00 065125(H) (CaAa) 0.0000 0.000 (Area)CCI-65FP- A No Surface Af 55.5830- 1 1 0.000 5.0000 12.5000 0.00 050125(H) (CaAa) 30.5830 0.000 (Area)CCI-65FP- B No Surface Af 55.5830- 1 1 0.000 5.0000 12.5000 0.00 050125(H) (CaAa) 30.5830 0.000 (Area)CCI-65FP- C No Surface Af 55.5830- 1 1 0.000 5.0000 12.5000 0.00 050125(H) (CaAa) 30.5830 0.000 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Exclude Componen Placement Total CAAA Weight or Shield From t Number Leg Torque Type ft ft2lft plf Calculation 1/2"Cable(Lights) C No No Inside Pole 107.5000- 1 No Ice 0.0000 0.40 0.0000 1/2"Ice 0.0000 0.40 *** 1"Ice 0.0000 0.40 HB114-1-0813U4- B No No Inside Pole 107.0000- 4 No Ice 0.0000 1.20 M5J(1-1/4) 0.0000 1/2"Ice 0:0000 1.20 1"Ice 0.0000 1.20 LDF2-50(3/8) B No No Inside Pole 98.0000- 2 No Ice 0.0000 0.08 0.0000 1/2"Ice 0.0000 0.08 1"Ice 0.0000 0.08 FB-L98-002- B No No Inside Pole 98.0000- 1 No Ice 0.0000 0.06 XXX(3/8) 0.0000 1/2"Ice 0.0000 0.06 1"Ice 0.0000 0.06 FB-L98B-034- B No No Inside Pole 98.0000- 1 No Ice 0.0000 0.05 XXXXXX(3/8) 0.0000 1/2"Ice 0.0000 0.05 1"Ice 0.0000 0.05 WR-VG86ST- B No No Inside Pole 98.0000- 2 No Ice 0.0000 0.58 BRD(3/4) 0.0000 1/2"Ice 0.0000 0.58 1"Ice 0.0000 0.58 WR-VG66ST- B No No Inside Pole 98.0000- 2 No Ice 0.0000 0.91 . BRD(7/8) 0.0000 1/2"Ice 0.0000 0.91 1"Ice 0.0000 0.91 LDF7-50A(1-5/8) B No No Inside Pole 98.0000- 12 No Ice 0.0000 0.82 0.0000 1/2"Ice 0.0000 0.82 1"Ice 0.0000 0.82 2.5"Flexible B No No Inside Pole 98.0000- 1 No Ice 0.0000 0.38 Conduit 0.0000 1/2"Ice 0.0000 0.38 1"Ice 0.0000 0.38 CU12PSM9P8XXX A No No Inside Pole 88.0000- 1 No Ice 0.0000 1.66 (1-3/8) 0.0000 1/2"Ice 0.0000 1.66 1"Ice 0.0000 1.66 LDF5-50A(718) B No No Inside Pole 78.0000- 12 No Ice 0.0000 0.33 0.0000 1/2"Ice 0.0000 0.33 1"Ice 0.0000 0.33 RFF-24SM-1206- B No No Inside Pole 78.0000- 3 No Ice 0.0000 1.48 618-APE(1-1/4) 0.0000 1/2"Ice 0.0000 1.48 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 13 Description Face Allow Exclude Componen Placement Total CAAA Weight or Shield From t Number Leg Torque Type ft ftz/ft plf Calculation 1"Ice 0.0000 1.48 Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 ft2 K L1 107.5000- A 0.000 0.000 0.000 0.000 0.00 102.5000 B 0.000 0.000 0.000 0.000 0.02 C 0.000 0.000 0.000 0.000 0.00 L2 102.5000- A 0.000 0.000 0.000 0.000 0.00 97.5000 B 0.000 0.000 0.000 0.000 0.03 C 0.000 0.000 0.000 0.000 0.00 L3 97.5000-92.5000 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.09 C 0.000 0.000 0.000 0.000 0.00 L4 92.5000-87.5000 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.09 C 0.000 0.000 0.000 0.000 0.00 L5 87.5000-82.5000 A 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.09 C 0.000 0.000 0.000 0.000 0.00 L6 82.5000-77.5000 A 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.10 C 0.000 0.000 0.000 0.000 0.00 L7 77.5000-71.7500 A 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.15 C 0.000 0.000 0.000 0.000 0.00 L8 71.7500-70.5000 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.03 C 0.000 0.000 0.000 0.000 0.00 L9 70.5000-65.5000 A 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.13 C 0.000 0.000 0.000 0.000 0.00 L10 65.5000-60.5000 A 0.000 0.000 0.493 0.000 0.01 B 0.000 0.000 0.000 0.000 0.13 C 0.000 0.000 0.000 0.000 0.00 1-11 60.5000-55.5000 A 0.000 0.000 4.999 0.000 0.04 B 0.000 0.000 0.069 0.000 0.13 C 0.000 0.000 0.069 0.000 0.00 L12 55.5000-53.5830 A 0.000 0.000 3.488 0.000 0.02 B 0.000 0.000 1.597 0.000 0.05 C 0.000 0.000 1.597 0.000 0.00 L13 53.5830-53.3330 A 0.000 0.000 0.455 0.000 0.00 B 0.000 0.000 0.208 0.000 0.01 C 0.000 0.000 0.208 0.000 0.00 L14 53.3330-48.3330 A 0.000 0.000 9.097 0.000 0.04 B 0.000 0.000 4.167 0.000 0.13 C 0.000 0.000 4.167 0.000 0.00 L15 48.3330-43.3330 A 0.000 0.000 9.097 0.000 0.04 B 0.000 0.000 4.167 0.000 0.13 C 0.000 0.000 4.167 0.000 0.00 L16 43.3330-35.5000 A 0.000 0.000 14.251 0.000 0.07 B 0.000 0.000 6.527 0.000 0.21 C 0.000 0.000 6.527 0.000 0.00 L17 35.5000-35.0000 A 0.000 0.000' 0.910 0.000 0.00 B 0.000 0.000 0.417 0.000 0.01 C 0.000 0.000 0.417 0.000 0.00 L18 35.0000-30.0000 A 0.000 0.000 9.152 0.000 0.04 B 0.000 0.000 4.223 0.000 0.13 C 0.000 0.000 4.223 0.000 0.00 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 14 Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 ft2 K L19 30.0000-27.7500 A 0.000 0.000 4.656 0.000 0.02 B 0.000 0.000 2.438 0.000 0.06 C 0.000 0.000 2.438 0.000 0.00 L20 27.7500-27.5000 A 0.000 0.000 0.517 0.000 0.00 B 0.000 0.000 0.271 0.000 0.01 C 0.000 0.000 0.271 0.000 0.00 L21 27.5000-22.5000 A 0.000 0.000 10.347 0.000 0.04 B 0.000 0.000 5.417 0.000 0.13 C 0.000 0.000 5.417 0.000 0.00 L22 22.5000-17.5000 A 0.000 0.000 10.347 0.000 0.04 B 0.000 0.000 5.417 0.000 0.13 C 0.000 0.000 5.417 0.000 0.00 L23 17.5000-12.5000 A 0.000 0.000 10.347 0.000 0.04 B 0.000 0.000 5.417 0.000 0.13 C 0.000 0.000 5.417 0.000 0.00 L24 12.5000-7.5000 A 0.000 0.000 10.347 0.000 0.04 B 0.000 0.000 5.417 0.000 0.13 C 0.000 0.000 5.417 0.000 0.00 L25 7.5000-2.5000 A 0.000 0.000 10.347 0.000 0.04 B 0.000 0.000 5.417 0.000 0.13 C 0.000 0.000 5.417 0.000 0.00 L26 2.5000-0.0000 A 0.000 0.000 5.173 0.000 0.02 B 0.000 0.000 2.708 0.000 0.07 C 0.000 0.000 2.708 0.000 0.00 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice AR AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n ft Leg in ft2 ft2 ft2 ft2 L1 107.5000- A 0.954 0.000 0.000 0.000 0.000 0.00 102.5000 B 0.000 0.000 0.000 0.000 0.02 C 0.000 0.000 0.000 0.000 0.00 L2 102.5000- A 0.950 0.000 0.000 0.000 0.000 0.00 97.5000 B 0.000 0.000 0.000 0.000 0.03 C 0.000 0.000 0.000 0.000 0.00 L3 97.5000-92.5000 A 0.945 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.09 C 0.000 0.000 0.000 0.000 0.00 L4 92.5000-87.5000 A 0.940 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.09 C 0.000 0.000 0.000 0.000 0.00 L5 87.5000-82.5000 A 0.934 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.09 C 0.000 0.000 0.000 0.000 0.00 L6 82.5000-77.5000 A 0.929 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.10 C 0.000 0.000 0.000 0.000 0.00 L7 77.5000-71.7500 A 0.922 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.15 C 0.000 0.000 0.000 0.000 0.00 L8 71.7500-70.5000 A 0.918 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.03 C 0.000 0.000 0.000 0.000 0.00 L9 70.5000-65.5000 A 0.914 0.000 0.000 0.000 0.000 0.01 B 0.000 0.000 0.000 0.000 0.13 C 0.000 0.000 0.000 0.000 0.00 L10 65.5000-60.5000 A 0.907 0.000 0.000 0.843 0.000 0.02 B 0.000 0.000 0.000 0.000 0.13 C 0.000 0.000 0.000 0.000 0.00 L11 60.5000-55.5000 A 0.899 0.000 0.000 8.495 0.000 0.10 B 0.000 0.000 0.084 0.000 0.13 C 0.000 0.000 0.084 0.000 0.00 L12 55.5000-53.5830 A 0.894 0.000 0.000 5.160 0.000 0.05 B 0.000 0.000 1.940 0.000 0.06 C 0.000 0.000 1.940 0.000 0.01 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 15 Tower Tower Face Ice AR AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n It Leg in ftZ ft, ftZ ftZ K L13 53.5830-53.3330 A 0.892 0.000 0.000 0.673 0.000 0.01 B 0.000 0.000 0.253 0.000 0.01 C 0.000 0.000 0.253 0.000 0.00 L14 53.3330-48.3330 A 0.888 0.000 0.000 13.435 0.000 0.12 B 0.000 0.000 5.054 0.000 0.16 C 0.000 0.000 5.054 0.000 0.03 L15 48.3330-43.3330 A 0.878 0.000 0.000 13.403 0.000 0.12 B 0.000 0.000 5.045 0.000 0.16 C 0.000 0.000 5.045 0.000 0.03 L16 43.3330-35.5000 A 0.865 0.000 0.000 20.926 0.000 0.19 B 0.000 0.000 7.883 0.000 0.25 C 0.000 0.000 7.883 0.000 0.04 L17 35.5000-35.0000 A 0.856 0.000 0.000 1.336 0.000 0.01 B 0.000 0.000 0.503 0.000 0.02 C 0.000 0.000 0.503 0.000 0.00 L18 35.0000-30.0000 A 0.849 0.000 0.000 13.341 0.000 0.12 B 0.000 0.000 5.057 0.000 0.16 C 0.000 0.000 5.057 0.000 0.03 L19 30.0000-27.7500 A 0.839 0.000 0.000 6.532 0.000 0.05 B 0.000 0.000 2.815 0.000 0.07 C 0.000 0.000 2.815 0.000 0.01 L20 27.7500-27.5000 A 0.835 0.000 0.000 0.725 0.000 0.01 B 0.000 0.000 0.313 0.000 0.01 C 0.000 0.000 0.313 0.000 0.00 L21 27.5000-22.5000 A 0.827 0.000 0.000 14.473 0.000 0.12 B 0.000 0.000 6.243 0.000 0.16 C 0.000 0.000 6.243 0.000 0.03 L22 22.5000-17.5000 A 0.808 0.000 0.000 14.409 0.000 0.12 B 0.000 0.000 6.225 0.000 0.16 C 0.000 0.000 6.225 0.000 0.03 L23 17.5000-12.5000 A 0.786 0.000 0.000 14.328 0.000 0.12 B .0.000 0.000 6.202 0.000 0.16 C 0.000 0.000 6.202 0.000 0.03 L24 12.5000-7.5000 A 0.754 0.000 0.000 14.219 0.000 0.11 B 0.000 0.000 6.171 0.000 0.16 C 0.000 0.000 6.171 0.000 0.03 L25 7.5000-2.5000 A 0.704 0.000 0.000 14.042 0.000 0.11 B 0.000 0.000 6.120 0.000 0.16 C 0.000 0.000 6.120 0.000 0.03 L26 2.5000-0.0000 A 0.613 0.000 0.000 6.862 0.000 0.05 B 0.000 0.000 3.015 0.000 0.08 C 0.000 0.000 3.015 0.000 0.01 Feed Line Center of Pressure Section Elevation CPx CPz CPx CPz Ice Ice It in in in in L1 107.5000- 0.0000 0.0000 0.0000 0.0000 102.5000 L2 102.5000-97.5000 0.0000 0.0000 0.0000 0.0000 L3 97.5000-92.5000 0.0000 0.0000 0.0000 0.0000 L4 92.5000-87.5000 0.0000 0.0000 0.0000 0.0000 L5 87.5000-82.5000 0.0000 0.0000 0.0000 0.0000 L6 82.5000-77.5000 0.0000 0.0000 0.0000 0.0000 L7 77.5000-71.7500 0.0000 0.0000 0.0000 0.0000 L8 71.7500-70.5000 0.0000 0.0000 0.0000 0.0000 L9 70.5000-65.5000 0.0000 0.0000 0.0000 0.0000 L10 65.5000-60.5000 -0.4552 -0.6528 -0.4440 -0.6237 L11 60.5000-55.5000 -3.0940 -4.4377 -2.6956 -3.7877 L12 55.5000-53.5830 -1.7106 -2.4537 -1.8068 -2.5391 L13 53.5830-53.3330 -1.7167 -2.4623 -1.8128 -2.5476 L14 53.3330-48.3330 -1.7300 -2.4815 -1.8259 -2.5663 L15 48.3330-43.3330 -1.7550 -2.5174 -1.8502 -2.6010 L16 43.3330-35.5000 -1.7864 -2.5626 -1.8803 -2.6440 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 16 Section Elevation CPx CPz CPx CPz Ice Ice It in in in in L17 35.5000-35.0000 -1.7912 -2.5695 -1.8857 -2.6516 L18 35.0000-30.0000 -1.7937 -2.5732 -1.8903 -2.6588 L19 30.0000-27.7500 -1.6093 -2.3087 -1.7670 -2.4860 L20 27.7500-27.5000 -1.6154 -2.3175 -1.7727 -2.4941 L21 27.5000-22.5000 -1.6271 -2.3343 -1.7830 -2.5091 L22 22.5000-17.5000 -1.6491 -2.3660 -1.8017 -2.5363 L23 17.5000-12.5000 -1.6708 -2.3972 -1.8186 -2.5612 L24 12.5000-7.5000 -1.6922 -2.4280 -1.8326 -2.5825 L25 7.5000-2.5000 -1.7133 -2.4583 -1.8405 -2.5961 L26 2.5000-0.0000 -1.7289 -2.4807 -1.8304 -2.5865 Note:For pole sections,center of pressure calculations do not consider feed line shielding. Shielding Factor Ka Tower Feed Line Description Feed Line Ka Ka Section Record No. Segment No Ice Ice Elev. L10 19 HCS 6X12 4AWG(1-5/8) 60.50- 1.0000 1.0000 61.00 L10 20 LCF78-50JA(7/8) 60.50- 1.0000 1.0000 61.00 L11 19 HCS 6X12 4AWG(1-5/8) 55.50- 1.0000 1.0000 60.50 L11 20 LCF78-50JA(7/8) 55.50- 1.0000 1.0000 60.50 L11 26 (Area)CCI-65FP-050125 55.50- 1.0000 1.0000 (H) 55.58 L11 27 (Area)CCI-65FP-050125 55.50- 1.0000 1.0000 (H) 55.58 1-11 28 (Area)CCI-65FP-050125 55.50- 1.0000 1.0000 (H) 55.58 L12 19 HCS 6X12 4AWG(1-5/8) 53.58- 1.0000 1.0000 55.50 L12 20 LCF78-50JA(7/8) 53.58- 1.0000 1.0000 55.50 L12 26 (Area)CCI-65FP-050125 53.58- 1.0000 1.0000 (H) 55.50 L12 27 (Area)CCI-65FP-050125 53.58- 1.0000 1.0000 (H) 55.50 L12 28 (Area)CCI-65FP-050125 53.58- 1.0000 1.0000 (H) 55.50 L13 19 HCS 6X12 4AWG(1-5/8) 53.33- 1.0000 1.0000 53.58 L13 20 LCF78-50JA(7/8) 53.33- 1.0000 1.0000 53.58 L13 26 (Area)CCI-65FP-050125 53.33- 1.0000 1.0000 (H) 53.58 L13 27 (Area)CCI-65FP-050125 53.33- 1.0000 1.0000 (H) 53.58 L13 28 (Area)CCI-65FP-050125 53.33- 1.0000 1.0000 (H) 53.58 L14 19 HCS 6X12 4AWG(1-5/8) 48.33- 1.0000 1.0000 53.33 L14 20 LCF78-50JA(7/8) 48.33- 1.0000 1.0000 53.33 L14 26 (Area)CCI-65FP-050125 48.33- 1.0000 1.0000 (H) 53.33 L14 27 (Area)CCI-65FP-050125 48.33- 1.0000 1.0000 (H) 53.33 L14 28 (Area)CCI-65FP-050125 48.33- 1.0000 1.0000 (H) 53.33 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 17 Tower Feed Line Description Feed Line Ka Ka Section Record No. Segment No Ice Ice Elev. L15 19 HCS 6X12 4AWG(1-5/8) 43.33- 1.0000 1.0000 48.33 L15 20 LCF78-50JA(7/8) 43.33- 1.0000 1.0000 48.33 L15 26 (Area)CCI-65FP-050125 43.33- 1.0000 1.0000 (H) 48.33 L15 27 (Area)CCI-65FP-050125 43.33- 1.0000 1.0000 (H) 48.33 L15 28 (Area)CCI-65FP-050125 43.33- 1.0000 1.0000 (H) 48.33 L16 19 HCS 6X12 4AWG(1-5/8) 35.50- 1.0000 1.0000 43.33 L16 20 LCF78-50JA(7/8) 35.50- 1.0000 1.0000 43.33 L16 26 (Area)CCI-65FP-050125 35.50- 1.0000 1.0000 (H) 43.33 L16 27 (Area)CCI-65FP-050125 35.50- 1.0000 1.0000 (H) 43.33 L16 28 (Area)CCI-65FP-050125 35.50- 1.0000 1.0000 (H) 43.33 L17 19 HCS 6X12 4AWG(1-5/8) 35.00- 1.0000 1.0000 35.50 L17 20 LCF78-50JA(7/8) 35.00- 1.0000 1.0000 35.50 L17 26 (Area)CCI-65FP-050125 35.00- 1.0000 1.0000 (H) 35.50 L17 27 (Area)CCI-65FP-050125 35.00- 1.0000 1.0000 (H) 35.50 L17 28 (Area)CCI-65FP-050125 35.00- 1.0000 1.0000 (H) 35.50 L18 19 HCS 6X12 4AWG(1-5/8) 30.00- 1.0000 1.0000 35.00 L18 20 LCF78-50JA(7/8) 30.00- 1.0000 1.0000 35.00 L18 23 (Area)CCI-65FP-065125 30.00- 1.0000 1.0000 (H) 30.50 L18 24 (Area)CCI-65FP-065125 30.00- 1.0000 1.0000 (H) 30.50 L18 25 (Area)CCI-65FP-065125 30.00- 1.0000 1.0000 (H) 30.50 L18 26 (Area)CCI-65FP-050125 30.58- 1.0000 1.0000 (H) 35.00 L18 27 (Area)CCI-65FP-050125 30.58- 1.0000 1.0000 (H) 35.00 L18 28 (Area)CCI-65FP-050125 30.58- 1.0000 1.0000 (H) 35.00 L19 19 HCS 6X12 4AWG(1-5/8) 27.75- 1.0000 1.0000 30.00 L19 20 LCF78-50JA(7/8) 27.75- 1.0000 1.0000 30.00 L19 23 (Area)CCI-65FP-065125 27.75- 1.0000 1.0000 (H) 30.00 L19 24 (Area)CCI-65FP-065125 27.75- 1.0000 1.0000 (H) 30.00 L19 25 (Area)CCI-65FP-065125 27.75- 1.0000 1.0000 (H) 30.00 L20 19 HCS 6X12 4AWG(1-5/8) 27.50- 1.0000 1.0000 27.75 L20 20 LCF78-50JA(7/8) 27.50- 1.0000 1.0000 27.75 L20 23 (Area)CCI-65FP-065125 27.50- 1.0000 1.0000 (H) 27.75 L20 24 (Area)CCI-65FP-065125 27.50- 1.0000 1.0000 (H) 27.75 L20 25 (Area)CCI-65FP-065125 27.50- 1.0000 1.0000 (H) 27.75 L21 19 HCS 6X12 4AWG(1-5/8) 22.50- 1.0000 1.0000 27.50 L21 20 LCF78-50JA(7/8) 22.50- 1.0000 1.0000 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 18 Tower Feed Line Description Feed Line K Ka Section Record No. Segment No Ice Ice Elev. 27.50 L21 23 (Area)CCI-65FP-065125 22.50- 1.0000 1.0000 (H) 27.50 L21 24 (Area)CCI-65FP-065125 22.50- 1.0000 1.0000 (H) 27.50 L21 25 (Area)CCI-65FP-065125 22.50- 1.0000 1.0000 (H) 27.50 L22 19 HCS 6X12 4AWG(1-5/8) 17.50- 1.0000 1.0000 22.50 L22 20 LCF78-50JA(7/8) 17.50- 1.0000 1.0000 22.50 L22 23 (Area)CCI-65FP-065125 17.50- 1.0000 1.0000 (H) 22.50 L22 24 (Area)CCI-65FP-065125 17.50- 1.0000 1.0000 (H) 22.50 L22 25 (Area)CCI-65FP-065125 17.50- 1.0000 1.0000 (H) 22.50 L23 19 HCS 6X12 4AWG(1-5/8) 12.50- 1.0000 1.0000 17.50 L23 20 LCF78-50JA(7/8) 12.50- 1.0000 1.0000 17.50 L23 23 (Area)CCI-65FP-065125 12.50- 1.0000 1.0000 (H) 17.50 L23 24 (Area)CCI-65FP-065125 12.50- 1.0000 1.0000 (H) 17.50 L23 25 (Area)CCI-65FP-065125 12.50- 1.0000 1.0000 (H) 17.50 L24 19 HCS 6X12 4AWG(1-5/8) 7.50-12.50 1.0000 1.0000 L24 20 LCF78-50JA(7/8) 7.50-12.50 1.0000 1.0000 L24 23 (Area)CCI-65FP-065125 7.50-12.50 1.0000 1.0000 (H) L24 24 (Area)CCI-65FP-065125 7.50-12.50 1.0000 1.0000 (H) L24 25 (Area)CCI-65FP-065125 7.50-12.50 1.0000 1.0000 (H) L25 19 HCS 6X12 4AWG(1-5/8) 2.50-7.50 1.0000 1.0000 L25 20 LCF78-50JA(718) 2.50-7.50 1.0000 1.0000 L25 23 (Area)CCI-65FP-065125 2.50-7.50 1.0000 1.0000 (H) L25 24 (Area)CCI-65FP-065125 2.50-7.50 1.0000 1.0000 (H) L25 25 (Area)CCI-65FP-065125 2.50-7.50 1.0000 1.0000 (H) L26 19 HCS 6X12 4AWG(1-5/8) 0.00-2.50 1.0000 1.0000 L26 20 LCF78-50JA(7/8) 0.00-2.50 1.0000 1.0000 L26 23 (Area)CCI-65FP-065125 0.00-2.50 1.0000 1.0000 (H) L26 24 (Area)CCI-65FP-065125 0.00-2.50 1.0000 1.0000 (H) L26 25 (Area)CCI-65FP-065125 0.00-2.50 1.0000 1.0000 H Effective Width of Flat Linear Attachments / Feed Lines Tower Attachment Description Attachment Ratio Effective Section Record No. Segment Calculatio Width Elev. n Ratio Method L11 26 (Area)CCI-65FP-050125 55.50- Auto 0.0000 (H) 55.58 L11 27 (Area)CCI-65FP-050125 55.50-1 Auto 1 0.0000 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 19 Tower Attachment Description Attachment Ratio Effective Section Record No. Segment Calculatio Width Elev. n Ratio Method (H) 55.58 L11 28 (Area)CCI-65FP-050125 55.50- Auto 0.0000 (H) 55.58 L12 26 (Area)CCI-65FP-050125 53.58- Auto 0.0000 (H) 55.50 L12 27 (Area)CCI-65FP-050125 53.58- Auto 0.0000 (H) 55.50 L12 28 (Area)CCI-65FP-050125 53.58- Auto 0.0000 (H) 55.50 L13 26 (Area)CCI-65FP-050125 53.33- Auto 0.0111 (H) 53.58 L13 27 (Area)CCI-65FP-050125 53.33- Auto 0.0111 (H) 53.58 L13 28 (Area)CCI-65FP-050125 53.33- Auto 0.0111 (H) 53.58 L14 26 (Area)CCI-65FP-050125 48.33- Auto 0.0019 (H) 53.33 L14 27 (Area)CCI-65FP-050125 48.33- Auto 0.0019 (H) 53.33 L14 28 (Area)CCI-65FP-050125 48.33- Auto 0.0019 (H) 53.33 L15 26 (Area)CCI-65FP-050125 43.33- Auto 0.0000 (H) 48.33 L15 27 (Area)CCI-65FP-050125 43.33- Auto 0.0000 (H) 48.33 L15 28 (Area)CCI-65FP-050125 43.33- Auto 0.0000 (H) 48.33 L16 26 (Area)CCI-65FP-050125 35.50- Auto 0.0000 (H) 43.33 L16 27 (Area)CCI-65FP-050125 35.50- Auto 0.0000 (H) 43.33 L16 28 (Area)CCI-65FP-050125 35.50- Auto 0.0000 (H) 43.33 L17 26 (Area)CCI-65FP-050125 35.00- Auto 0.0000 (H) 35.50 L17 27 (Area)CCI-65FP-050125 35.00- Auto 0.0000 (H) 35.50 L17 28 (Area)CCI-65FP-050125 35.00- Auto 0.0000 (H) 35.50 L18 23 (Area)CCI-65FP-065125 30.00- Auto 0.1251 (H) 30.50 L18 24 (Area)CCI-65FP-065125 30.00- Auto 0.1251 (H) 30.50 L18 25 (Area)CCI-65FP-065125 30.00- Auto 0.1251 (H) 30.50 L18 26 (Area)CCI-65FP-050125 30.58- Auto 0.0000 (H) 35.00 L18 27 (Area)CCI-65FP-050125 30.58- Auto 0.0000 (H) 35.00 L18 28 (Area)CCI-65FP-050125 30.58- Auto 0.0000 (H) 35.00 L19 23 (Area)CCI-65FP-065125 27.75- Auto 0.1192 (H) 30.00 L19 24 (Area)CCI-65FP-065125 27.75- Auto 0.1192 (H) 30.00 L19 25 (Area)CCI-65FP-065125 27.75- Auto 0.1192 (H) 30.00 L20 23 (Area)CCI-65FP-065125 27.50- Auto 0.1679 (H) 27.75 L20 24 (Area)CCI-65FP-065125 27.50- Auto 0.1679 (H) 27.75 L20 25 (Area)CCI-65FP-065125 27.50- Auto 0.1679 (H) 27.75 L21 23 (Area)CCI-65FP-065125 22.50- Auto 0.1565 (H) 27.50 L21 24 (Area)CCI-65FP-065125 22.50- Auto 0.1565 (H) 27.50 L21 25 (Area)CCI-65FP-065125 22.50- Auto 0.1565 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 20 Tower Attachment Description Attachment Ratio Effective Section Record No. Segment Calculatio Width Elev. n Ratio Method (H) 27.50 L22 23 (Area)CCI-65FP-065125 17.50- Auto 0.1315 (H) 22.50 L22 24 (Area)CCI-65FP-065125 17.50- Auto 0.1315 (H) 22.50 L22 25 (Area)CCI-65FP-065125 17.50- Auto 0.1315 (H) 22.50 L23 23 (Area)CCI-65FP-065125 12.50- Auto 0.1098 (H) 17.50 L23 24 (Area)CCI-65FP-065125 12.50- Auto 0.1098 (H) 17.50 L23 25 (Area)CCI-65FP-065125 12.50- Auto 0.1098 (H) 17.50 L24 23 (Area)CCI-65FP-065125 7.50-12.50 Auto 0.0864 (H) L24 24 (Area)CCI-65FP-065125 7.50-12.50 Auto 0.0864 (H) L24 25 (Area)CCI-65FP-065125 7.50-12.50 Auto 0.0864 (H) L25 23 (Area)CCI-65FP-065125 2.50-7.50 Auto 0.0630 (H) L25 24 (Area)CCI-65FP-065125 2.50-7.50 Auto 0.0630 (H) L25 25 (Area)CCI-65FP-065125 2.50-7.50 Auto 0.0630 (H) L26 23 (Area)CCI-65FP-065125 0.00-2.50 Auto 0.0468 (H) L26 24 (Area)CCI-65FP-065125 0.00-2.50 Auto 0.0468 (H) L26 25 (Area)CCI-65FP-065125 0.00-2.50 Auto 0.0468 H Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft (2)Side Lighting C From Leg 0.0000 0.00 107.5000 No Ice 0.1052 0.1052 0.01 0.00 1/2" 0.1701 0.1701 0.01 3.00 Ice 0.2333 0.2333 0.01 1"Ice Tx 2"Pipe Mount C From Leg b.0000 0.00 107.5000 No Ice 0.5826 0.5826 0.01 0.00 1/2" 0.7701 0.7701 0.02 1.50 Ice 0.9669 0.9669 0.02 1"Ice Top Hat-1.5ft.OD x 2ft C From Leg 0.0000 0.00 107.5000 No Ice 1.5000 1.5000 0.10 Tall 0.00 1/2" 2.3090 2.3090 0.13 1.00 Ice 2.5278 2.5278 0.17 1"Ice DT465B-2XR-V2 A From Leg 4.0000 0.00 107.0000 No Ice 5.2900 3.0500 0.06 0.00 1/2" 5.7500 3.4800 0.12 1.00 Ice 6.2200 3.9300 0.18 1"Ice DT465B-2XR-V2 B From Leg 4.0000 0.00 107.0000 No Ice 5.2900 3.0500 0.06 0.00 1/2" 5.7500 3.4800 0.12 1.00 Ice 6.2200 3.9300 0.18 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 21 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert It it ft2 ft2 K ft ° ft 1"Ice DT465B-2XR-V2 C From Leg 4.0000 0.00 107.0000 No Ice 5.2900 3.0500 0.06 0.00 1/2" 5.7500 3.4800 0.12 1.00 Ice 6.2200 3.9300 0.18 1"Ice APXVSPP18-C-A20 A From Leg 4.0000 0.00 107.0000 No Ice 4.6600 3.1100 0.07 0.00 1/2" 5.1200 3.5500 0.12 1.00 Ice 5.6000 4.0000 0.18 1"Ice APXVSPP18-C-A20 B From Leg 4.0000 0.00 107.0000 No Ice 4.6600 3.1100 0.07 0.00 1/2" 5.1200 3.5500 0.12 1.00 Ice 5.6000 -4.0000 0.18 1"Ice APXVSPP18-C-A20 C From Leg 4.0000 0.00 107.0000 No Ice 4.6600 3.1100 0.07 0.00 1/2" 5.1200 3.5500 0.12 1.00 Ice 5.6000 4.0000 0.18 1"Ice (2)80OMHZ 2X50W RRH A From Leg 4.0000 0.00 107.0000 No Ice 2.1342 1.7730 0.05 0.00 1/2" 2.3195 1.9461 0.07 1.00 Ice 2.5123 2.1267 0.10 1"Ice (2)80OMHZ 2X50W RRH B From Leg 4.0000 0.00 107.0000 No Ice 2.1342 1.7730 0.05 0.00 1/2" 2.3195 1.9461 0.07 1.00 Ice 2.5123 2.1267 0.10 1"Ice (2)80OMHZ 2X50W RRH C From Leg 4.0000 0.00 107.0000 No Ice 2.1342 1.7730 0.05 0.00 1/2" 2.3195 1.9461 0.07 1.00 Ice 2.5123 2.1267 0.10 1"Ice FZHN A From Leg 4.0000 0.00 107.0000 No Ice 2.0197 0.6068 0.04 0.00 1/2" 2.1967 0.7146 0.06 0.00 Ice 2.3811 0.8294 0.07 1"Ice FZHN B From Leg 4.0000 0.00 107.0000 No Ice 2.0197 0.6068 0.04 0.00 1/2" 2.1967 0.7146 0.06 0.00 Ice 2.3811 0.8294 0.07 1"Ice FZHN C From Leg 4.0000 0.00 107.0000 No Ice 2.0197 0.6068 0.04 0.00 1/2" 2.1967 0.7146 0.06 0.00 Ice 2.3811 0.8294 0.07 1"Ice 190OMHZ RRH(65MHZ) A From Leg 4.0000 0.00 107.0000 No Ice 2.3125 2.3750 0.06 0.00 1/2" 2.5168 2.5809 0.08 0.00 Ice 2.7284 2.7943 0.11 1"Ice 190OMHZ RRH(65MHZ) B From Leg 4.0000 0.00 107.0000 No Ice 2.3125 2.3750 0.06 0.00 1/2" 2.5168 2.5809 0.08 0.00 Ice 2.7284 2.7943 0.11 1"Ice 190OMHZ RRH(65MHZ) C From Leg 4.0000 0.00 107.0000 No Ice 2.3125 2.3750 0.06 0.00 1/2" 2.5168 2.5809 0.08 0.00 Ice 2.7284 2.7943 0.11 1"Ice Platform Mount[LP 301-1] C None 0.00 107.0000 No Ice 23.8100 23.8100 1.59 1/2" 30.2400 30.2400 2.10 Ice 36.3300 36.3300 2.73 1"Ice (3)NNHH-65A-R4 w/ A From Leg 4.0000 0.00 98.0000 No Ice 5.6600 3.0500 0.09 Mount Pipe 0.00 1/2" 6.0400 3.3900 0.15 0.00 Ice 6.4400 3.7400 0.23 1"Ice (3)NNHH-65A-R4 w/ B From Leg 4.0000 0.00 98.0000 No Ice 5.6600 3.0500 0.09 Mount Pipe 0.00 1/2" 6.0400 3.3900 0.15 0.00 Ice 6.4400 3.7400 0.23 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 22 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert It ft ft2 ft2 K ft ° ft 1"Ice (3)NNHH-65A-R4 w/ C From Leg 4.0000 0.00 98.0000 No Ice 5.6600 3.0500 0.09 Mount Pipe 0.00 1/2" 6.0400 3.3900 0.15 0.00 Ice 6.4400 3.7400 0.23 1"Ice BAND 5 AHCA RRH4X40 A From Leg 4.0000 0.00 98.0000 No Ice 1.3131 0.7458 0.04 0.00 1/2" 1.4563 0.8600 0.05 1.00 Ice 1.6070 0.9815 0.07 1"Ice BAND 5 AHCA RRH4X40 B From Leg 4.0000 0.00 98.0000 No Ice 1.3131 0.7458 0.04 0.00 1/2" 1.4563 0.8600 0.05 1.00 Ice 1.6070 0.9815 0.07 1"Ice BAND 5 AHCA RRH4X40 C From Leg 4.0000 0.00 98.0000 No Ice 1.3131 0.7458 0.04 0.00 1/2" 1.4563 0.8600 0.05 1.00 Ice 1.6070 0.9815 0.07 1"Ice AHLBA A From Leg 4.0000 0.00 98.0000 No Ice 3.6712 2.3051 0.10 0.00 1/2" 3.9196 2.5127 0.13 1.00 Ice 4.1755 2.7273 0.16 1"Ice AHLBA B From Leg 4.0000 0.00 98.0000 No Ice 3.6712 2.3051 0.10 0.00 1/2" 3.9196 2.5127 0.13 1.00 Ice 4.1755 2.7273 0.16 1"Ice AHLBA C From Leg 4.0000 0.00 98.0000 No Ice 3.6712 2.3051 0.10 0.00 1/2" 3.9196 2.5127 0.13 1.00 Ice 4.1755 2.7273 0.16 1"Ice B25 RRH4X30 A From Leg 4.0000 0.00 98.0000 No Ice 2.2000 1.7417 0.06 0.00 1/2" 2.3926 1.9204 0.08 1.00 Ice 2.5926 2.1065 0.10 1"Ice B25 RRH4X30 B From Leg 4.0000 0.00 98.0000 No Ice 2.2000 1.7417 0.06 0.00 1/2" 2.3926 1.9204 0.08 1.00 Ice 2.5926 2.1065 0.10 1"Ice B25 RRH4X30 C From Leg 4.0000 0.00 98.0000 No Ice 2.2000 1.7417 0.06 0.00 1/2" 2.3926 1.9204 0.08 1.00 Ice 2.5926 2.1065 0.10 1"Ice DC6-48-60-18-8F A From Leg 4.0000 0.00 98.0000 No Ice 1.2117 1.2117 0.02 0.00 1/2" 1.8924 1.8924 0.04 0.00 Ice 2.1051 2.1051 0.07 1"Ice DC6-48-60-18-8F C From Leg 4.0000 0.00 98.0000 No Ice 1.2117 1.2117 0.02 0.00 1/2" 1.8924 1.8924 0.04 0.00 Ice 2.1051 2.1051 0.07 1"Ice RRH4X25-WCS A From Leg 4.0000 0.00 98.0000 No Ice 3.3367 3.8352 0.09 0.00 1/2" 3.5863 4.0945 0.13 0.00 Ice 3.8430 4.3640 0.16 1"Ice RRH4X25-WCS B From Leg 4.0000 0.00 98.0000 No Ice 3.3367 3.8352 0.09 0.00 1/2" 3.5863 4.0945 0.13 0.00 Ice 3.8430 4.3640 0.16 1"Ice RRH4X25-WCS C From Leg 4.0000 0.00 98.0000 No Ice 3.3367 3.8352 0.09 0.00 1/2" 3.5863 4.0945 0.13 0.00 Ice 3.8430 4.3640 0.16 1"Ice Platform Mount[LP 1201- C None 0.00 98.0000 No Ice 26.3900 26.3900 2.36 1-HR-1] 1/2" 31.4000 31.4000 3.06 Ice 36.2000 36.2000 3.86 1"Ice tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 23 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft (2)6'x 2"Mount Pipe A From Leg 4.0000 0.00 98.0000 No Ice 1.4250 1.4250 0.02 0.00 1/2" 1.9250 1.9250 0.03 0.00 Ice 2.2939 2.2939 0.05 1"Ice (2)6'x 2"Mount Pipe B From Leg 4.0000 0.00 98.0000 No Ice 1.4250 1.4250 0.02 0.00 1/2" 1.9250 1.9250 0.03 0.00 Ice 2.2939 2.2939 0.05 1"Ice (2)6'x 2"Mount Pipe C From Leg 4.0000 0.00 98.0000 No Ice 1.4250 1.4250 0.02 0.00 1/2" 1.9250 1.9250 0.03 0.00 Ice 2.2939 2.2939 0.05 1"Ice MX08FRO665-21 w/ A From Leg 4.0000 0.00 88.0000 No Ice 8.0100 4.2300 0.11 Mount Pipe 0.00 1/2" 8.5200 4.6900 0.19 0.00 Ice 9.0400 5.1600 0.29 1"Ice MX08FR0665-21 w/ B From Leg 4.0000 0.00 88.0000 No Ice 8.0100 4.2300 0.11 Mount Pipe 0.00 1/2" 8.5200 4.6900 0.19 0.00 Ice 9.0400 5.1600 0.29 1"Ice MX08FRO665-21 w/ C From Leg 4.0000 0.00 88.0000 No Ice 8.0100 4.2300 0.11 Mount Pipe 0.00 1/2" 8.5200 4.6900 0.19 0.00 Ice 9.0400 5.1600 0.29 1"Ice TA08025-6604 A From Leg 4.0000 0.00 88.0000 No Ice 1.9635 0.9811 0.06 0.00 1/2" 2.1378 1.1117 0.08 0.00 Ice 2.3195 1.2496 0.10 1"Ice TA08025-6604 B From Leg 4.0000 0.00 88.0000 No Ice 1.9635 0.9811 0.06 0.00 1/2" 2.1378 1.1117 0.08 0.00 Ice 2.3195 1.2496 0.10 1"Ice TA08025-6604 C From Leg 4.0000 0.00 88.0000 No Ice 1.9635 0.9811 0.06 0.00 1/2" 2.1378 1.1117 0.08 0.00 Ice 2.3195 1.2496 0.10 1"Ice TA08025-13605 A From Leg 4.0000 0.00 88.0000 No Ice 1.9635 1.1295 0.08 0.00 1/2" 2.1378 1.2666 0.09 0.00 Ice 2.3195 1.4112 0.11 1"Ice TA08025-6605 B From Leg 4.0000 0.00 88.0000 No Ice 1.9635 1.1295 0.08 0.00 1/2" 2.1378 1.2666 0.09 0.00 Ice 2.3195 1.4112 0.11 1"Ice TA08025-13605 C From Leg 4.0000 0.00 88.0000 No Ice 1.9635 1.1295 0.08 0.00 1/2" 2.1378 1.2666 0.09 0.00 Ice 2.3195 1.4112 0.11 1"Ice RDIDC-9181-PF-48 A From Leg 4.0000 0.00 88.0000 No Ice 2.3118 1.2931 0.02 0.00 1/2" 2.5022 1.4479 0.04 0.00 Ice 2.7000 1.6101 0.06 1"Ice Commscope MC-PK8-DSH C None 0.00 88.0000 No Ice 34.2400 34.2400 1.75 1/2" 62.9500 62.9500 2.10 Ice 91.6600 91.6600 2.45 1"Ice (2)8'x 2"Mount Pipe A From Leg 4.0000 0.00 88.0000 No Ice 1.9000 1.9000 0.03 0.00 1/2" 2.7281 2.7281 0.04 0.00 Ice 3.4009 3.4009 0.06 1"Ice (2)8'x 2"Mount Pipe B From Leg 4.0000 0.00 88.0000 No Ice 1.9000 1.9000 0.03 0.00 1/2" 2.7281 2.7281 0.04 0.00 Ice 3.4009 3.4009 0.06 1"Ice tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 24 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft (2)8'x 2"Mount Pipe C From Leg 4.0000 0.00 88.0000 No Ice 1.9000 1.9000 0.03 0.00 1/2" 2.7281 2.7281 0.04 0.00 Ice 3.4009 3.4009 0.06 1"Ice (2)X7CQAP-465-VRO A From Leg 4.0000 0.00 78.0000 No Ice 7.5600 3.7300 0.05 0.00 1/2" 8.2400 4.3300 0.09 0.00 Ice 8.9300 4.9500 0.14 1"Ice (2)X7CAP-FRO-440-VRO B From Leg 4.0000 0.00 78.0000 No Ice 11.1500 3.2100 0.06 0.00 1/2" 11.8400 3.7500 0.12 0.00 Ice 12.5500 4.3000 0.19 1"Ice (2)X7CQAP-465-VRO C From Leg 4.0000 0.00 78.0000 No Ice 7.5600 3.7300 0.05 0.00 1/2" 8.2400 4.3300 0.09 0.00 Ice 8.9300 4.9500 0.14 1"Ice RFV01U-DIA A From Leg 4.0000 0.00 78.0000 No Ice 1.8750 1.2500 0.08 0.00 1/2" 2.0454 1.3926 0.10 0.00 Ice 2.2231 1.5426 0.12 1"Ice RFV01U-D1A B From Leg 4.0000 0.00 78.0000 No Ice 1.8750 1.2500 0.08 0.00 1/2" 2.0454 1.3926 0.10 0.00 Ice 2.2231 1.5426 0.12 1"Ice RFV01U-D1A C From Leg 4.0000 0.00 78.0000 No Ice 1.8750 1.2500 0.08 0.00 1/2" 2.0454 1.3926 0.10 0.00 Ice 2.2231 1.5426 0.12 1"Ice RXXDC-3315-PF-48 A From Leg 4.0000 0.00 78.0000 No Ice 3.0123 1.9629 0.02 0.00 1/2" 3.2311 2.1512 0.05 0.00 Ice 3.4572 2.3469 0.08 1"Ice RXXDC-3315-PF-48 B From Leg 4.0000 0.00 78.0000 No Ice 3.0123 1.9629 0.02 0.00 1/2" 3.2311 2.1512 0.05 0.00 Ice 3.4572 2.3469 0.08 1"Ice RXXDC-3315-PF-48 C From Leg 4.0000 0.00 78.0000 No Ice 3.0123 1.9629 0.02 0.00 1/2" 3.2311 2.1512 0.05 0.00 Ice 3.4572 2.3469 0.08 1"Ice RFV01 U-D2A A From Leg 4.0000 0.00 78.0000 No Ice 1.8750 1.0125 0.07 0.00 1/2" 2.0454 1.1445 0.09 0.00 Ice 2.2231 1.2840 0.11 1"Ice RFV01 U-D2A B From Leg 4.0000 0.00 78.0000 No Ice 1.8750 1.0125 0.07 0.00 1/2" 2.0454 1.1445 0.09 0.00 Ice 2.2231 1.2840 0.11 1"Ice RFV01U-D2A C From Leg 4.0000 0.00 78.0000 No Ice 1.8750 1.0125 0.07 0.00 1/2" 2.0454 1.1445 0.09 0.00 Ice 2.2231 1.2840 0.11 1"Ice Platform Mount[LP 301- C None 0.00 78.0000 No Ice 35.0300 35.0300 1.86 1_KCKR] 1/2" 44.4600 44.4600 2.52 Ice 53.7200 53.7200 3.33 1"Ice (2)1-5/8"x1-5/8"Unistrut A From Leg 4.0000 0.00 78.0000 No Ice 2.2750 0.0257 0.01 (12-ft Horizontal) 0.00 1/2" 3.2232 0.0511 0.03 0.00 Ice 4.1800 0.0851 0.06 1"Ice (2)1-5/8"x1-5/8"Unistrut B From Leg 4.0000 0.00 78.0000 No Ice 2.2750 0.0257 0.01 (12-ft Horizontal) 0.00 1/2" 3.2232 0.0511 0.03 0.00 Ice 4.1800 0.0851 0.06 1"Ice tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 25 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft it ft2 ft2 K ft ° ft (2)1-5/8'x1-5/8"Unistrut C From Leg 4.0000 0.00 78.0000 No Ice 2.2750 0.0257 0.01 (12-ft Horizontal) 0.00 1/2" 3.2232 0.0511 0.03 0.00 Ice 4.1800 0.0851 0.06 1"Ice kk* ERICSSON AIR 21 64A A From Leg 3.0000 0.00 61.0000 No Ice 3.1400 2.5900 0.11 132P w/Mount Pipe 0.00 1/2" 3.4500 2.8800 0.16 0.00 Ice 3.7700 3.1900 0.22 1"Ice ERICSSON AIR 21 134A B From Leg 3.0000 0.00 61.0000 No Ice 3.1400 2.5900 0.11 62P w/Mount Pipe 0.00 1/2" 3.4500 2.8800 0.16 0.00 Ice 3.7700 3.1900 0.22 1"Ice ERICSSON AIR 21 64A C From Leg 3.0000 0.00 61.0000 No Ice 3.1400 2.5900 0.11 132P w/Mount Pipe 0.00 1/2" 3.4500 2.8800 0.16 0.00 Ice 3.7700 3.1900 0.22 1"Ice APXVAARR24_43-U-NA20 A From Leg 3.0000 0.00 61.0000 No Ice 14.6900 6.8700 0.19 W/Mount Pipe 0.00 1/2" 15.4600 7.5500 0.31 0.00 Ice 16.2300 8.2500 0.46 1"Ice APXVAARR24 43-U-NA20 B From Leg 3.0000 0.00 61.0000 No Ice 14.6900 6.8700 0.19 w/Mount Pipe 0.00 1/2" 15.4600 7.5500 0.31 0.00 Ice 16.2300 8.2500 0.46 1"Ice APXVAARR24_43-U-NA20 C From Leg 3.0000 0.00 61.0000 No Ice 14.6900 6.8700 0.19 W/Mount Pipe 0.00 1/2" 15.4600 7.5500 0.31 0.00 Ice 16.2300 8.2500 0.46 1"Ice S20057A1 A From Leg 3.0000 0.00 61.0000 No Ice 0.7040 0.3532 0.01 0.00 1/2" 0.8166 0.4438 0.02 1.00 Ice 0.9366 0.5414 0.02 1"Ice S20057A1 B From Leg 3.0000 0.00 61.0000 No Ice 0.7040 0.3532 0.01 0.00 1/2" 0.8166 0.4438 0.02 1.00 Ice 0.9366 0.5414 0.02 1"Ice S20057A1 C From Leg 3.0000 0.00 61.0000 No Ice 0.7040 0.3532 0.01 0.00 1/2" 0.8166 0.4438 0.02 1.00 Ice 0.9366 0.5414 0.02 1"Ice RRUS 11 B2 A From Leg 3.0000 0.00 61.0000 No Ice 2.8333 1.1821 0.05 0.00 1/2" 3.0426 1.3299 0.07 1.00 Ice 3.2593 1.4848 0.10 1"Ice RRUS 11 B2 B From Leg 3.0000 0.00 61.0000 No Ice 2.8333 1.1821 0.05 0.00 1/2" 3.0426 1.3299 0.07 1.00 Ice 3.2593 1.4848 0.10 1"Ice RRUS 11 B2 C From Leg 3.0000 0.00 61.0000 No Ice 2.8333 1.1821 0.05 0.00 1/2" 3.0426 1.3299 0.07 1.00 Ice 3.2593 1.4848 0.10 1"Ice RADIO 4449 612/1371 A From Leg 3.0000 0.00 61.0000 No Ice 1.6500 1.1625 0.07 0.00 1/2" 1.8104 1.3012 0.09 0.00 Ice 1.9781 1.4473 0.11 1"Ice RADIO 4449 612/671 B From Leg 3.0000 0.00 61.0000 No Ice 1.6500 1.1625 0.07 0.00 1/2" 1.8104 1.3012 0.09 0.00 Ice 1.9781 1.4473 0.11 1"Ice RADIO 4449 612/671 C From Leg 3.0000 0.00 61.0000 No Ice 1.6500 1.1625 0.07 0.00 1/2" 1.8104 1.3012 0.09 0.00 Ice 1.9781 1.4473 0.11 1"Ice tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 26 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 rte K ft ° ft T-Arm Mount[TA 702-3] C None 0.00 61.0000 No Ice 4.7500 4.7500 0.34 1/2" 5.8200 5.8200 0.43 Ice 6.9800 6.9800 0.55 1"Ice Dishes Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight or Type Type Horz Adjustment Beam Diameter Area Leg Lateral Width Vert ft ft ft ftZ K -98- 2-ft Dia.Dish w/o B Paraboloid w/o From 4.0000 -90.00 98.0000 2.0000 No Ice 3.1400 0.04 Radome Radome Leg 2.00 1/2"Ice 3.4100 0.05 2.00 1"Ice 3.6800 0.07 Load Combinations Comb. Description No. 1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg-No Ice 3 0.9 Dead+1.0 Wind 0 deg-No Ice 4 1.2 Dead+1.0 Wind 30 deg-No Ice 5 0.9 Dead+1.0 Wind 30 deg-No Ice 6 1.2 Dead+1.0 Wind 60 deg-No Ice 7 0.9 Dead+1.0 Wind 60 deg-No Ice 8 1.2 Dead+1.0 Wind 90 deg-No Ice 9 0.9 Dead+1.0 Wind 90 deg-No Ice 10 1.2 Dead+1.0 Wind 120 deg-No Ice 11 0.9 Dead+1.0 Wind 120 deg-No Ice 12 1.2 Dead+1.0 Wind 150 deg-No Ice 13 0.9 Dead+1.0 Wind 150 deg-No Ice 14 1.2 Dead+1.0 Wind 180 deg-No Ice 15 0.9 Dead+1.0 Wind 180 deg-No Ice 16 1.2 Dead+1.0 Wind 210 deg-No Ice 17 0.9 Dead+1.0 Wind 210 deg-No Ice 18 1.2 Dead+1.0 Wind 240 deg-No Ice 19 0.9 Dead+1.0 Wind 240 deg-No Ice 20 1.2 Dead+1.0 Wind 270 deg-No Ice 21 0.9 Dead+1.0 Wind 270 deg-No Ice 22 1.2 Dead+1.0 Wind 300 deg-No Ice 23 0.9 Dead+1.0 Wind 300 deg-No Ice 24 1.2 Dead+1.0 Wind 330 deg-No Ice 25 0.9 Dead+1.0 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 27 Comb. Description No. 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg-Service 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 de -Service Maximum Member Forces Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft L1 107.5- Pole Max Tension 1 0.00 0.00 0.00 102.5 Max.Compression 26 -6.11 0.20 -0.12 Max.Mx 20 -3.25 21.73 -0.08 Max.My 14 -3.25 0.12 -21.68 Max.Vy 20 -4.52 21.73 -0.08 Max.Vx 14 4.52 0.12 -21.68 Max.Torque 12 -0.13 L2 102.5-97.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -15.20 0.24 -0.27 Max.Mx 20 -8.26 49.08 -0.68 Max.My 14 -8.26 0.48 -49.35 Max.Vy 20 -10.21 49.08 -0.68 Max.Vx 14 10.26 0.48 -49.35 Max.Torque 21 1.54 L3 97.5-92.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -15.83 0.24 -0.27 Max.Mx 20 -8.72 101.24 -1.79 Max.My 14 -8.71 1.15 -101.75 Max.Vy 20 -10.65 101.24 -1.79 Max.Vx 14 10.70 1.15 -101.75 Max.Torque 21 1.41 L4 92.5-87.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -21.32 0.24 0.06 Max.Mx 20 -12.15 157.43 -2.81 Max.My 14 -12.15 1.83 -158.08 Max.Vy 20 -14.74 157.43 -2.81 Max.Vx 14 14.83 1.83 -158.08 Max.Torque 21 1.41 L5 87.5-82.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -21.99 0.24 0.06 Max.Mx 20 -12.67 232.19 -3.94 Max.My 14 -12.66 2.50 -233.30 Max.Vy 20 -15.18 232.19 -3.94 Max.Vx 14 15.27 2.50 -233.30 Max.Torque 20 1.15 L6 82.5-77.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -28.57 -0.19 -0.18 Max.Mx 20 -16.22 311.23 -5.08 Max.My 14 -16.22 2.96 -312.91 Max.Vy 20 -20.06 311.23 -5.08 Max.Vx 14 19.99 2.96 -312.91 Max.Torque 20 1.15 L7 77.5-71.75 Pole Max Tension 1 0.00 0.00 0.00 tnxTower Report-version 8.1.1.0 April 11,2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 28 Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-rt kip-ft Max.Compression 26 -28.87 -0.19 -0.18 Max.Mx 20 -16.47 351.51 -5.24 Max.My 14 -16.47 2.95 -353.04 Max.Vy 20 -20.23 351.51 -5.24 Max.Vx 14 20.15 2.95 -353.04 Max.Torque 20 1.04 L8 71.75-70.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -30.12 -0.19 -0.18 Max.Mx 20 -17.44 453.82 -5.66 Max.My 14 -17.44 2.91 -454.98 Max.Vy 20 -20.70 453.82 -5.66 Max.Vx 14 20.62 2.91 -454.98 Max.Torque 20 1.04 L9 70.5-65.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -30.95 -0.19 -0.18 Max.Mx 20 -18.16 558.27 -6.08 Max.My 14 -18.17 2.88 -559.06 Max.Vy 20 -21.10 558.27 -6.08 Max.Vx 14 21.03 2.88 -559.06 Max.Torque 20 1.04 L10 65.5-60.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -35.23 -0.18 -0.18 Max.Mx 20 -20.73 666.16 -6.49 Max.My 14 -20.74 2.85 -666.57 Max.Vy 20 -23.83 666.16 -6.49 Max.Vx 14 23.75 2.85 -666.57 Max.Torque 20 1.04 1-11 60.5-55.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -36.19 -0.07 -0.11 Max.Mx 20 -21.56 786.22 -6.87 Max.My 14 -21.57 2.86 -786.18 Max.Vy 20 -24.20 786.22 -6.87 Max.Vx 14 24.12 2.86 -786.18 Max.Torque 20 1.03 L12 55.5- Pole Max Tension 1 0.00 0.00 0.00 53.583 Max.Compression 26 -36.59 -0.02 -0.09 Max.Mx 20 -21.88 832.73 -7.02 Max.My 14 -21.88 2.86 -832.52 Max.Vy 20 -24.35 832.73 -7.02 Max.Vx 14 24.27 2.86 -832.52 Max.Torque 20 1.03 L13 53.583- Pole Max Tension 1 0.00 0.00 0.00 53.333 Max.Compression 26 -36.66 -0.02 -0.08 Max.Mx 20 -21.96 838.82 -7.04 Max.My 14 -21.97 2.86 -838.58 Max.Vy 20 -24.35 838.82 -7.04 Max.Vx 14 24.27 2.86 -838.58 Max.Torque 20 1.03 L14 53.333- Pole Max Tension 1 0.00 0.00 0.00 48.333 Max.Compression 26 -38.09 0.10 -0.02 Max.Mx 20 -23.15 961.64 -7.41 Max.My 14 -23.15 2.87 -960.95 Max.Vy 20 -24.77 961.64 -7.41 Max.Vx 14 24.70 2.87 -960.95 Max.Torque 20 1.03 L15 48.333- Pole Max Tension 1 0.00 0.00 0.00 43.333 Max.Compression 26 -39.54 0.21 0.05 Max.Mx 20 -24.36 1086.52 -7.78 Max.My 14 -24.37 2.89 -1085.38 Max.Vy 20 -25.18 1086.52 -7.78 Max.Vx 14 25.10 2.89 -1085.38 Max.Torque 20 1.03 L16 43.333- Pole Max Tension 1 0.00 0.00 0.00 35.5 Max.Compression 26 -40.52 0.29 0.09 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 29 Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft Max.Mx 20 -25.18 1170.87 -8.03 Max.My 14 -25.19 2.89 -1169.42 Max.Vy 20 -25.44 1170.87 -8.03 Max.Vx 14 25.36 2.89 -1169.42 Max.Torque 20 1.03 L17 35.5-35 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -42.75 0.41 0.16 Max.Mx 20 -27.00 1299.20 -8.40 Max.My 14 -27.01 2.91 -1297.29 Max.Vy 20 -25.88 1299.20 -8.40 Max.Vx 14 25.80 2.91 -1297.29 Max.Torque 20 1.03 L18 35-30 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -43.99 0.53 0.23 Max.Mx 20 -28.06 1429.36 -8.76 Max.My 14 -28.07. 2.92 -1426.99 Max.Vy 20 -26.19 1429.36 -8.76 Max.Vx 14 26.11 2.92 -1426.99 Max.Torque 20 1.03 L19 30-27.75 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -44.55 0.58 0.26 Max.Mx 20 -28.55 1488.41 -8.92 Max.My 14 -28.55 2.93 -1485.83 Max.Vy 20 -26.32 1488.41 -8.92 Max.Vx 14 26.24 2.93 -1485.83 Max.Torque 20 1.03 L20 27.75-27.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -44.64 0.59 0.27 Max.Mx 20 -28.64 1494.99 -8.94 Max.My 14 -28.65 2.93 -1492.39 Max.Vy 20 -26.32 1494.99 -8.94 Max.Vx 14 26.24 2.93 -1492.39 Max.Torque 20 1.03 L21 27.5-22.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -46.40 0.71 0.34 Max.Mx 20 -30.17 1627.50 -9.29 Max.My 14 -30.17 2.94 -1624.44 Max.Vy 20 -26.68 1627.50 -9.29 Max.Vx 14 26.60 2.94 -1624.44 Max.Torque 20 1.03 L22 22.5-17.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -48.18 0.83 0.41 Max.Mx 20 -31.72 1761.69 -9.64 Max.My 14 -31.72 2.95 -1758.17 Max.Vy 20 -27.00 1761.69 -9.64 Max.Vx 14 26.93 2.95 -1758.17 Max.Torque 20 1.03 L23 17.5-12.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -49.96 0.96 0.48 Max.Mx 20 -33.30 1897.41 -9.99 Max.My 14 -33.30 2.97 -1893.43 Max.Vy 20 -27.29 1897.41 -9.99 Max.Vx 14 27.22 2.97 -1893.43 Max.Torque 20 1.03 L24 12.5-7.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -51.75 1.08 0.55 Max.Mx 20 -34.90 2034.57 -10.33 Max.My 14 -34.90 2.98 -2030.13 Max.Vy 20 -27.58 2034.57 -10.33 Max.Vx 14 27.50 2.98 -2030.13 Max.Torque 20 1.03 L25 7.5-2.5 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -53.54 1.20 0.62 Max.Mx 20 -36.52 2173.14 -10.67 Max.My 14 -36.52 3.00 -2168.23 Max.Vy 20 -27.85 2173.14 -10.67 Max.Vx 14 27.78 3.00 -2168.23 Max.Torque 20 1.03 L26 2.5-0 Pole Max Tension 1 0.00 0.00 0.00 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 30 Sectio Elevation Component Condition Gov. Axial Major Axis MinorAxis n It Type Load Moment Moment No. Comb. K kip-ft kip-ft Max.Compression 26 -54.42 1.25 0.65 Max.Mx 20 -37.34 2242.93 -10.83 Max.My 14 -37.34 3.00 -2237.79 Max.Vy 20 -28.00 2242.93 -10.83 Max.Vx 14 27.92 3.00 -2237.79 Max.Torque 20 1.03 Maximum Reactions Location Condition Gov. Vertical Horizontal,X Horizontal,Z Load K K K Comb. Pole Max.Vert 36 54.42 6.49 -0.02 Max.H. 21 28.01 27.97 -0.07 Max.H, 2 37.35 0.13 27.82 Max.MX 2 2230.20 0.13 27.82 Max.M. 8 2234.66 -27.91 -0.11 Max.Torsion 20 1.03 27.97 -0.07 Min.Vert 5 28.01 -13.87 24.05 Min.HX 8 37.35 -27.91 -0.11 Min.Hz 15 28.01 -0.01 -27.90 Min.MX 14 -2237.79 -0.01 -27.90 Min.MZ 20 -2242.93 27.97 -0.07 Min.Torsion 5 -0.20 -13.87 24.05 Tower Mast Reaction Summary Load Vertical Shear, Shear, Overturning Overturning Torque Combination Moment,MX Moment,M. K K K kip-ft kip-ft kip-ft Dead Only 31.13 0.00 0.00 -0.18 0.50 0.00 1.2 Dead+1.0 Wind 0 deg- 37.35 -0.13 -27.82 -2230.20 11.27 0.02 No Ice 0.9 Dead+1.0 Wind 0 deg- 28.01 -0.13 -27.82 -2208.11 11.02 0.02 No Ice 1.2 Dead+1.0 Wind 30 deg- 37.35 13.87 -24.05 -1928.53 -1110.79 0.19 No Ice 0.9 Dead+1.0 Wind 30 deg- 28.01 13.87 -24.05 -1909.42 -1099.97 0.20 No Ice 1.2 Dead+1.0 Wind 60 deg- 37.35 24.13 -13.80 -1105.98 -1932.64 0.09 No Ice 0.9 Dead+1.0 Wind 60 deg- 28.01 24.13 -13.80 -1094.99 -1913.70 0.09 No Ice 1.2 Dead+1.0 Wind 90 deg- 37.35 27.91 0.11 8.40 -2234.66 0.04 No Ice 0.9 Dead+1.0 Wind 90 deg- 28.01 27.91 0.11 8.37 -2212.75 0.04 No Ice 1.2 Dead+1.0 Wind 120 deg 37.35 24.20 13.99 1120.06 -1936.85 -0.04 -No Ice 0.9 Dead+1.0 Wind 120 deg 28.01 24.20 13.99 1109.06 -1917.89 -0.04 -No Ice 1.2 Dead+1.0 Wind 150 deg 37.35 13.92 24.30 1950.53 -1110.97 -1.02 -No Ice 0.9 Dead+1.0 Wind 150 deg 28.01 13.92 24.30 1931.30 -1100.18 -1.02 -No Ice 1.2 Dead+1.0 Wind 180 deg 37.35 0.01 27.90 2237.79 3.00 -0.75 -No Ice 0.9 Dead+1.0 Wind 180 deg 28.01 0.01 27.90 2215.72 2.80 -0.76 -No Ice 1.2 Dead+1.0 Wind 210 deg 37.35 -13.91 24.12 1935.50 1116.29 -0.60 -No Ice tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 31 Load Vertical Shea& Shear, Overturning Overturning Torque Combination Moment,M Moment,M� K K K kip-ft kip-ft kip-ft 0.9 Dead+1.0 Wind 210 deg 28.01 -13.91 24.12 1916.41 1105.10 -0.61 -No Ice 1.2 Dead+1.0 Wind 240 deg 37.35 -24.13 13.94 1120.86 1934.28 -0.64 -No Ice 0.9 Dead+1.0 Wind 240 deg 28.01 -24.13 13.94 1109.81 1915.03 -0.65 -No Ice 1.2 Dead+1.0 Wind 270 deg 37.35 -27.97 0.07 10.83 2242.93 -1.03 -No Ice 0.9 Dead+1.0 Wind 270 deg 28.01 -27.97 0.07 10.74 2220.63 -1.03 -No Ice 1.2 Dead+1.0 Wind 300 deg 37.35 -24.20 -13.99 -1120.83 1937.86 0.06 -No Ice 0.9 Dead+1.0 Wind 300 deg 28.01 -24.20 -13.99 -1109.72 1918.59 0.06 -No Ice 1.2 Dead+1.0 Wind 330 deg 37.35 -14.05 -24.15 -1935.01 1125.70 0.04 -No Ice 0.9 Dead+1.0 Wind 330 deg 28.01 -14.05 -24.15 -1915.86 1114.45 0.04 -No Ice 1.2 Dead+1.0 Ice+1.0 Temp 54.42 0.00 0.00 -0.65 1.25 0.00 1.2 Dead+1.0 Wind 0 54.42 -0.02 -6.47 -521.21 3.01 -0.03 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 30 54.42 3.23 -5.59 -451.06 -258.41 0.00 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 60 54.42 5.60 -3.21 -259.46 -449.80 -0.01 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 90 54.42 6.48 0.02 0.67 -519.99 -0.00 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 120 54.42 5.61 3.24 260.36 -450.33 0.00 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 150 54.42 3.23 5.63 453.59 -258.03 -0.16 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 180 54.42 -0.00 6.48 521.35 1.98 -0.10 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 210 54.42 -3.23 5.61 451.08 261.80 -0.08 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 240 54.42 -5.61 3.24 260.93 452.49 -0.09 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 270 54.42 -6.49 0.02 1.59 523.89 -0.18 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 300 54.42 -5.61 -3.25 -261.76 452.90 0.00 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 330 54.42 -3.25 -5.61 -452.00 263.10 -0.02 deg+1.0 Ice+1.0 Temp Dead+Wind 0 deg-Service 31.13 -0.03 -5.76 -459.36 2.70 -0.00 Dead+Wind 30 deg-Service 31.13 2.87 -4.98 -397.24 -228.35 0.03 Dead+Wind 60 deg-Service 31.13 5.00 -2.86 -227.87 -397.58 0.01 Dead+Wind 90 deg-Service 31.13 5.78 0.02 1.60 -459.77 0.01 Dead+Wind 120 deg- 31.13 5.01 2.90 230.51 -398.45 -0.01 Service Dead+Wind 150 deg- 31.13 2.88 5.03 401.51 -228.39 -0.21 Service Dead+Wind 180 deg- 31.13 0.00 5.78 460.66 0.99 -0.15 Service Dead+Wind 210 deg- 31.13 -2.88 4.99 398.42 230.24 -0.12 Service Dead+Wind 240 deg- 31.13 -5.00 2.89 230.67 398.68 -0.13 Service Dead+Wind 270 deg- 31.13 -5.79 0.02 2.10 462.24 -0.21 Service Dead+Wind 300 deg- 31.13 -5.01 -2.90 -230.93 399.42 0.01 Service Dead+Wind 330 deg- 31.13 -2.91 -5.00 -398.58 232.18 0.01 Service Solution Summary tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 32 ,Sum of Applied Forces Sum of Reactions Load PX Py PZ PX PY PZ %Error Comb. K K K K K K 1 0.00 -31.13 0.00 0.00 31.13 0.00 0.000% 2 -0.13 -37.35 -27.82 0.13 37.35 27.82 0.000% 3 -0.13 -28.01 -27.82 0.13 28.01 27.82 0.000% 4 13.87 -37.35 -24.05 -13.87 37.35 24.05 0.000% 5 13.87 -28.01 -24.05 -13.87 28.01 24.05 0.000% 6 24.13 -37.35 -13.80 -24.13 37.35 13.80 0.000% 7 24.13 -28.01 -13.80 -24.13 28.01 13.80 0.000% 8 27.91 -37.35 0.11 -27.91 37.35 -0.11 0.000% 9 27.91 -28.01 0.11 -27.91 28.01 -0.11 0.000% 10 24.20 -37.35 13.99 -24.20 37.35 -13.99 0.000% 11 24.20 -28.01 13.99 -24.20 28.01 -13.99 0.000% 12 13.92 -37.35 24.30 -13.92 37.35 -24.30 0.000% 13 13.92 -28.01 24.30 -13.92 28.01 -24.30 0.000% 14 0.01 -37.35 27.90 -0.01 37.35 -27.90 0.000% 15 0.01 -28.01 27.90 -0.01 28.01 -27.90 0.000% 16 -13.91 -37.35 24.12 13.91 37.35 -24.12 0.000% 17 -13.91 -28.01 24.12 13.91 28.01 -24.12 0.000% 18 -24.13 -37.35 13.94 24.13 37.35 -13.94 0.000% 19 -24.13 -28.01 13.94 24.13 28.01 -13.94 0.000% 20 -27.97 -37.35 0.07 27.97 37.35 -0.07 0.000% 21 -27.97 -28.01 0.07 27.97 28.01 -0.07 0.000% 22 -24.20 -37.35 -13.99 24.20 37.35 13.99 0.000% 23 -24.20 -28.01 -13.99 24.20 28.01 13.99 0.000% 24 -14.05 -37.35 -24.15 14.05 37.35 24.15 0.000% 25 -14.05 -28.01 -24.15 14.05 28.01 24.15 0.000% 26 0.00 -54.42 0.00 0.00 54.42 0.00 0.000% 27 -0.02 -54.42 -6.47 0.02 54.42 6.47 0.000% 28 3.23 -54.42 -5.59 -3.23 54.42 5.59 0.000% 29 5.60 -54.42 -3.21 -5.60 54.42 3.21 0.000% 30 6.48 -54.42 0.02 -6.48 54.42 -0.02 0.000% 31 5.61 -54.42 3.24 -5.61 54.42 -3.24 0.000% 32 3.23 -54.42 5.63 -3.23 54.42 -5.63 0.000% 33 -0.00 -54.42 6.48 0.00 54.42 -6.48 0.000% 34 -3.23 -54.42 5.61 3.23 54.42 -5.61 0.000% 35 -5.61 -54.42 3.24 5.61 54.42 -3.24 0.000% 36 -6.49 -54.42 0.02 6.49 54.42 -0.02 0.000% 37 -5.61 -54.42 -3.25 5.61 54.42 3.25 0.000% 38 -3.25 -54.42 -5.61 3.25 54.42 5.61 0.000% 39 -0.03 -31.13 -5.76 0.03 31.13 5.76 0.000% 40 2.87 -31.13 -4.98 -2.87 31.13 4.98 0.000% 41 5.00 -31.13 -2.86 -5.00 31.13 2.86 0.000% 42 5.78 -31.13 0.02 -5.78 31.13 -0.02 0.000% 43 5.01 -31.13 2.90 -5.01 31.13 -2.90 0.000% 44 2.88 -31.13 5.03 -2.88 31.13 -5.03 0.000% 45 0.00 -31.13 5.78 -0.00 31.13 -5.78 0.000% 46 -2.88 -31.13 4.99 2.88 31.13 -4.99 0.000% 47 -5.00 -31.13 2.89 5.00 31.13 -2.89 0.000% 48 -5.79 -31.13 0.02 5.79 31.13 -0.02 0.000% 49 -5.01 -31.13 -2.90 5.01 31.13 2.90 0.000% 50 -2.91 -31.13 -5.00 2.91 31.13 5.00 0.000% Non-Linear Convergence Results Load Converged? Number Displacement Force Combination of Cycles Tolerance Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 5 0.00000001 0.00008397 3 Yes 5 0.00000001 0.00003096 4 Yes 7 0.00000001 0.00000791 5 Yes 6 0.00000001 0.00005463 6 Yes 7 0.00000001 0.00000782 7 Yes 6 0.00000001 0.00005396 8 Yes 5 0.00000001 0.00008589 9 Yes 5 0.00000001 0.00003242 10 Yes 7 0.00000001 0.00000792 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 33 11 Yes 6 0.00000001 0.00005462 12 Yes 7 0.00000001 0.00000819 13 Yes 6 0.00000001 0.00005653 14 Yes 6 0.00000001 0.00000684 15 Yes 5 0.00000001 0.00006258 16 Yes 7 0.00000001 0.00000779 17 Yes 6 0.00000001 0.00005371 18 Yes 7 0.00000001 0.00000809 1.9 Yes 6 0.00000001 0.00005590 20 Yes 6 0.00000001 0.00001193 21 Yes 6 0.00000001 0.00000400 22 Yes 7 0.00000001 0.00000794 23 Yes 6 0.00000001 0.00005481 24 Yes 7 0.00000001 0.00000795 25 Yes 6 0.00000001 0.00005481 26 Yes 4 0.00000001 0.00000001 27 Yes 7 0.00000001 0.00000894 28 Yes 7 0.00000001 0.00000983 29 Yes 7 0.00000001 0.00000983 30 Yes 7 0.00000001 0.00000893 31 Yes 7 0.00000001 0.00000985 32 Yes 7 0.00000001 0.00000989 33 Yes 7 0.00000001 0.00000896 34 Yes 7 0.00000001 0.00000988 35 Yes 7 0.00000001 0.00000990 36 Yes 7 0.00000001 0.00000898 37 Yes 7 0.00000001 0.00000988 38 Yes 7 0.00000001 0.00000989 39 Yes 5 0.00000001 0.00001405 40 Yes 5 0.00000001 0.00004549 41 Yes 5 0.00000001 0.00004460 42 Yes 5 0.00000001 0.00001408 43 Yes 5 0.00000001 0.00004535 44 Yes 5 0.00000001 0.00004917 45 Yes 5 0.00000001 0.00001523 46 Yes 5 0.00000001 0.00004404 47 Yes 5 0.00000001 0.00004778 48 Yes 5 0.00000001 0.00001659 49 Yes 5 0.00000001 0.00004568 50 Yes 5 0.00000001 0.00004562 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L1 107.5-102.5 12.58 44 0.95 0.00 L2 102.5-97.5 11.59 44 0.95 0.00 L3 97.5-92.5 10.59 44 0.94 0.00 L4 92.5-87.5 9.61 44 0.93 0.00 L5 87.5-82.5 8.65 44 0.91 0.00 L6 82.5-77.5 7.72 44 0.88 0.00 L7 77.5-71.75 6.82 44 0.83 0.00 L8 75.5-70.5 6.47 44 0.82 0.00 L9 70.5-65.5 5.63 44 0.78 0.00 L10 65.5-60.5 4.84 44 0.73 0.00 L11 60.5-55.5 4.11 48 0.66 0.00 L12 55.5-53.583 3.45 48 0.59 0.00 L13 53.583-53.333 3.22 48 0.57 0.00 L14 53.333-48.333 3.19 48 0.56 0.00 L15 48.333-43.333 2.62 48 0.52 0.00 L16 43.333-35.5 2.11 48 0.47 0.00 L17 40-35 1.79 48 0.43 0.00 L18 35-30 1.36 48 0.40 0.00 L19 30-27.75 0.99 48 0.32 0.00 L20 27.75-27.5 0.84 48 0.28 0.00 L21 27.5-22.5 0.83 48 0.28 0.00 L22 22.5-17.5 0.56 48 0.23 0.00 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 34 Section Elevation Horz. Gov. Tilt Twist No. Deflection Load It in Comb. ° L23 17.5-12.5 0.34 48 0.18 0.00 L24 12.5-7.5 0.17 48 0.13 0.00 L25 7.5-2.5 0.06 48 0.08 0.00 L26 2.5-0 0.01 48 0.03 0.00 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 107.5000 (2)Side Lighting 44 12.58 0.95 0.00 57932 107.0000 DT465B-2XR-V2 44 12.48 0.95 0.00 57932 100.0000 2-ft Dia.Dish w/o Radome 44 11.09 0.95 0.00 37918 98.0000 (3)NNHH-65A-R4 w/Mount Pipe 44 10.69 0.94 0.00 28650 88.0000 MX08FRO665-21 w/Mount Pipe 44 8.74 0.91 0.00 10852 78.0000 (2)X7CQAP465-VRO 44 6.91 0.84 0.00 7161 61.0000 ERICSSON AIR 21 B4A B2P w/ 48 4.18 0.67 0.00 4353 Mount Pipe Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L1 107.5-102.5 61.14 12 4.64 0.00 L2 102.5-97.5 56.29 12 4.63 0.00 L3 97.5-92.5 51.48 12 4.59 0.00 L4 92.5-87.5 46.71 12 4.52 0.00 L5 87.5-82.5 42.04 12 4.41 0.00 L6 82.5-77.5 37.50 12 4.26 0.00 L7 77.5-71.75 33.15 12 4.06 0.00 L8 75.5-70.5 31.47 12 3.97 0.00 L9 70.5-65.5 27.39 12 3.82 0.00 L10 65.5-60.5 23.54 12 3.54 0.00 L11 60.5-55.5 19.99 12 3.23 0.00 L12 55.5-53.583 16.78 12 2.89 0.00 L13 53.583-53.333 15.65 12 2.76 0.00 L14 53.333-48.333 15.50 12 2.75 0.00 L15 48.333-43.333 12.75 12 2.52 0.00 L16 43.333-35.5 10.24 12 2.27 0.00 L17 40-35 8.72 12 2.10 0.00 L18 35-30 6.61 12 1.92 0.00 L19 30-27.75 4.79 12 1.55 0.00 L20 27.75-27.5 4.09 12 1.38 0.00 L21 27.5-22.5 4.02 12 1.37 0.00 L22 22.5-17.5 2.71 12 1.14 0.00 L23 17.5-12.5 1.65 12 0.89 0.00 L24 12.5-7.5 0.84 12 0.64 0.00 L25 7.5-2.5 0.31 12 0.39 0.00 L26 2.5-0 0.03 12 0.13 0.00 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 107.5000 (2)Side Lighting 12 61.14 4.64 0.01 12318 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 35 Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 107.0000 DT465B-2XR-V2 12 60.65 4.64 0.01 12318 100.0000 2-ft Dia.Dish w/o Radome 12 53.88 4.61 0.01 8026 98.0000 (3)NNHH-65A-R4 w/Mount Pipe 12 51.96 4.60 0.01 6045 88.0000 MX08FR0665-21 w/Mount Pipe 12 42.50 4.42 0.01 2266 78.0000 (2)X7CQAP-465-VRO 12 33.58 4.08 0.01 1489 61.0000 ERICSSON AIR 21 B4A 132P w/ 12 20.33 3.26 0.00 901 Mount Pipe Compression Checks Pole Design Data Section Elevation Size L L„ Kl/r A P„ Ratio No. P. ft ft ft int K K W„ L1 107.5-102.5 TP24.8008x24xO.2188 5.0000 0.0000 0.0 17.067 -3.25 921.65 0.004 (1) 7 L2 102.5-97.5 TP25.6017x24.8008xO.21 5.0000 0.0000 0.0 17.623 -8.26 951.68 0.009 (2) 88 7 L3 97.5-92.5(3) TP26.4025x25.6017xO.21 5.0000 0.0000 0.0 18.179 -8.71 981.71 0.009 88 7 L4 92.5-87.5(4) TP27.2034x26.4025xO.21 5.0000 0.0000 0.0 18.735 -12.15 1011.73 0.012 88 8 L5 87.5-82.5(5) TP28.0042x27.20340.21 5.0000 0.0000 0.0 19.291 -12.66 1041.76 0.012 88 8 L6 82.5-77.5(6) TP28.805x28.0042xO.218 5.0000 0.0000 0.0 19.847 -16.23 1071.78 0.015 8 8 L7 77.5-71.75 TP29.726x28.805xO.2188_ 5.7500 0.0000 0.0 20.070 -16.48 1083.79 0.015 (7) 2 L8 71.75-70.5 TP29.4886x28.68790.25 5.0000 0.0000 0.0 23.200 -17.45 1252.85 0.014 (8) 9 L9 70.5-65.5(9) TP30.2894x29.4886xO.25 5.0000 0.0000 0.0 23.836 -18.16 1287.16 0.014 3 L10 65.5-60.5 TP31.0902x30.2894xO.25 5.0000 0.0000 0.0 24.471 -20.73 1321.47 0.016 (10) 7 L11 60.5-55.5 TP31.8909x31.09020.25 5.0000 0.0000 0.0 25.107 -21.56 1355.78 0.016 (11) 1 L12 55.5-53.583 TP32.1979x31.8909xO.25 1.9170 0.0000 0.0 25.350 -21.87 1368.94 0.016 (12) 7 L13 53.583- TP32.238x32.1979xO.412 0.2500 0.0000 0.0 41.668 -21.96 2250.09 0.010 53.333(13) 5 3 L14 53.333- TP33.0388x32.2380.412 5.0000 0.0000 0.0 42.716 -23.14 2306.70 0.010 48.333(14) 5 7 L15 48.333- TP33.8395x33.0388xO.40 5.0000 0.0000 0.0 43.110 -24.36 2327.95 0.010 43.333(15) 63 1 L16 43.333-35.5 TP35.094x33.8395xO.406 7.8330 0.0000 0.0 43.798 -25.18 2365.11 0.011 (16) 3 4 L17 35.5-35(17) TP34.6741x33.8733xO.31 5.0000 0.0000 0.0 34.082 -27.00 1993.82 0.014 25 5 L18 35-30(18) TP35.475x34.6741xO.312 5.0000 0.0000 0.0 34.876 -28.06 2040.29 0.014 5 8 L19 30-27.75 TP35.8354x35.475xO.312 2.2500 0.0000 0.0 35.234 -28.55 2061.20 0.014 (19) 5 2 L20 27.75-27.5 TP35.8754x35.8354xO.51 0.2500 0.0000 0.0 57.523 -28.64 3365.15 0.009 (20) 25 9 L21 27.5-22.5 TP36.6762x35.8754xO.51 5.0000 0.0000 0.0 58.826 -30.17 3441.36 0.009 (21) 25 6 L22 22.5-17.5 TP37.4771x36.6762x0.5 5.0000 0.0000 0.0 58.682 -31.72 3432.93 0.009 (22) 6 L23 17.5-12.5 TP38.2779x37.47710.5 5.0000 0.0000 0.0 59.953 -33.30 3507.28 0.009 (23) 5 L24 12.5-7.5(24) TP39.0787x38.2779xO.49 5.0000 0.0000 0.0 60.469 -34.90 3537.43 0.010 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 36 Section Elevation Size L L„ KI/r A P. Ratio No. P„ ft ft ft int K K �Pn 38 0 L25 7.5-2.5(25) TP39.8796x39.07874.48 5.0000 0.0000 0.0 60.952 -36.52 3565.71 0.010 75 4 L26 2.5-0(26) TP40.28x39.8796x0.4875 2.5000 0.0000 0.0 61.571 -37.34 3601.96 0.010 9 Pole Bending Design Data Section Elevation Size M„x �Mnx Ratio M„y Wny Ratio No. Mux Muy ft kip-ft kip-ft �M. klp-ft kip-ft Wny L1 107.5-102.5 TP24.8008x24x0.2188 21.75 571.71 0.038 0.00 571.71 0.000 (1) L2 102.5-97.5 TP25.6017x24.8008x0.21 49.45 604.17 0.082 0.00 604.17 0.000 (2) 88 L3 97.5-92.5(3) TP26.4025x25.60170.21 102.02 637.15 0.160 0.00 637.15 0.000 88 L4 92.5-87.5(4) TP27.2034x26.4025x0.21 158.55 670.60 0.236 0.00 670.60 0.000 88 L5 87.5-82.5(5) TP28.004WT20340.21 233.89 704.49 0.332 0.00 704.49 0.000 88 L6 82.5-77.5(6) TP28.805x28.00420.218 313.51 738.79 0.424 0.00 738.79 0.000 8 L7 77.5-71.75 TP29.726x28.805x0.2188 353.53 752.62 0.470 0.00 752.62 0.000 (7) L8 71.75-70.5 TP29.4886x28.68790.25 455.18 914.13 0.498 0.00 914.13 0.000 (8) L9 70.5-65.5(9) TP30.2894x29.4886x0.25 559.29 957.32 0.584 0.00 957.32 0.000 L10 65.5-60.5 TP31.0902x30.28940.25 667.33 1001.04 0.667 0.00 1001.04 0.000 (10) L11 60.5-55.5 TP31.8909x31.09020.25 787.46 1045.28 0.753 0.00 1045.28 0.000 (11) L12 55.5-53.583 TP32.1979x31.89094.25 833.99 1062.36 0.785 0.00 1062.36 0.000 (12) L13 53.583- TP32.238x32.1979x0.412 840.08 1860.71 0.451 0.00 1860.71 0.000 53.333(13) 5 L14 53.333- TP33.0388x32.238x0.412 962.97 1956.13 0.492 0.00 1956.13 0.000 48.333(14) 5 L15 48.333- TP33.8395x33.03880.40 1087.91 2023.97 0.538 0.00 2023.97 0.000 43.333(15) 63 L16 43.333-35.5 TP35.09433.83950.406 1172.30 2089.50 0.561 0.00 2089.50 0.000 (16) 3 L17 35.5-35(17) TP34.6741x33.8733x0.31 1300.68 1720.26 0.756 0.00 1720.26 0.000 25 L18 35-30(18) TP35.475x34.6741x0.312 1430.89 1789.72 0.800 0.00 1789.72 0.000 5 L19 30-27.75 TP35.835435.4750.312 1489.97 1821.22 0.818 0.00 1821.22 0.000 (19) 5 L20 27.75-27.5 TP35.875435.83540.51 1496.55 3087.45 0.485 0.00 3087.45 0.000 (20) 25 L21 27.5-22.5 TP36.676205.87540.51 1629.11 3229.89 0.504 0.00 3229.89 0.000 (21) 25 L22 22.5-17.5 TP37.477106.6762x0.5 1763.35 3296.56 0.535 0.00 3296.56 0.000 (22) L23 17.5-12.5 TP38.2779x37.47710.5 1899.12 3441.88 0.552 0.00 3441.88 0.000 (23) L24 12.5-7.5(24) TP39.078708.27790.49 2036.32 3547.16 0.574 0.00 3547.16 0.000 38 L25 7.5-2.5(25) TP39.8796x39.07870.48 2174.92 3651.82 0.596 0.00 3651.82 0.000 75 L26 2.5-0(26) TP40.2809.87960.4875 2244.73 3726.90 0.602 0.00 3726.90 0.000 tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 37 Pole Shear Design Data Section Elevation Size Actual Vn Ratio Actual �Tn Ratio No. Vu Vu Tu T„ ft K K �Vn kip-ft kip-ft �Tn L1 107.5-102.5 TP24.8008x24x0.2188 4.52 276.50 0.016 0.00 595.23 0.000 (1) L2 102.5-97.5 TP25.6017x24.8008x0.21 10.29 285.50 0.036 1.21 634.65 0.002 (2) 88 L3 97.5-92.5(3) TP26.4025x25.60170.21 10.74 294.51 0.036 0.96 675.33 0.001 88 L4 92.5-87.5(4) TP27.2034x26.40250.21 14.85 303.52 0.049 0.96 717.27 0.001 88 L5 87.5-82.5(5) TP28.004WT20340.21 15.29 312.53 0.049 0.83 760.48 0.001 88 L6 82.5-77.5(6) TP28.805x28.0042x0.218 19.93 321.54 0.062 0.83 804.94 0.001 8 L7 77.5-71.75 TP29.726x28.8050.2188 20.10 325.14 0.062 0.61 823.09 0.001 (7) L8 71.75-70.5 TP29.4886x28.6879x0.25 20.57 375.85 0.055 0.61 962.40 0.001 (8) L9 70.5-65.5(9) TP30.2894x29.4886x0.25 21.13 386.15 0.055 1.02 1015.84 0.001 L10 65.5-60.5 TP31.0902x30.28940.25 23.86 396.44 0.060 1.02 1070.72 0.001 (10) L11 60.5-55.5 TP31.8909x31.09020.25 24.23 406.74 0.060 1.02 1127.04 0.001 (11) L12 55.5-53.583 TP32.1979x31.89090.25 24.38 410.68 0.059 1.02 1149.03 0.001 (12) L13 53.583- TP32.238x32.19790.412 24.38 675.03 0.036 1.02 1881.38 0.001 53.333(13) 5 L14 53.333- TP33.0388x32.2380.412 24.81 692.01 0.036 1.02 1977.24 0.001 48.333(14) 5 L15 48.333- TP33.8395x33.03880.40 25.21 698.38 0.036 1.02 2044.81 0.000 43.333(15) 63 L16 43.333-35.5 TP35.09433.83950.406 25.47 709.53 0.036 1.02 2110.63 0.000 (16) 3 L17 35.5-35(17) TP34.6741x33.8733x0.31 25.91 598.15 0.043 1.02 1799.96 0.001 25 L18 35-30(18) TP35.475x34.6741x0.312 26.22 612.09 0.043 1.02 1884.83 0.001 5 L19 30-27.75 TP35.835435.4750.312 26.35 618.36 0.043 1.02 1923.67 0.001 (19) 5 L20 27.75-27.5 TP35.875435.83540.51 26.35 1009.55 0.026 1.02 3126.47 0.000 (20) 25 L21 27.5-22.5 TP36.6762x35.87540.51 26.71 1032.41 0.026 1.02 3269.68 0.000 (21) 25 L22 22.5-17.5 TP37.4771x36.6762x0.5 27.03 1029.88 0.026 1.02 3335.03 0.000 (22) L23 17.5-12.5 TP38.2779x37.4771x0.5 27.32 1052.18 0.026 1.02 3481.05 0.000 (23) .L24 12.5-7.5(24) TP39.0787x38.27790.49 27.61 1061.23 0.026 1.02 3585.98 0.000 38 L25 7.5-2.5(25) TP39.8796x39.07870.48 27.89 1069.71 0.026 1.02 3690.26 0.000 75 L26 2.5-0(26) TP40.28x39.8796x0.4875 28.03 1080.59 0.026 1.02 3765.66 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. P„ Mux M„y V„ T„ Stress Stress tt Wn Wnx Wny �Vn �Tn Ratio Ratio L1 107.5-102.5 0.004 0.038 0.000 0.016 0.000 0.042 1.050 4.8.2 (1) L2 102.5-97.5 0.009 0.082 0.000 0.036 0.002 0.092 1.050 4.8.2 (2) tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 38 Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. P„ MIX M„Y V„ T„ Stress Stress ft �Pn �M„X �Mny �Vn �Tn Ratio Ratio L3 97.5-92.5(3) 0.009 0.160 0.000 0.036 0.001 0.170 1.050 4.8.2 L4 92.5-87.5(4) 0.012 0.236 0.000 0.049 0.001 0.251 1.050 4.8.2 L5 87.5-82.5(5) 0.012 0.332 0.000 0.049 0.001 0.347 1.050 4.8.2 L6 82.5-77.5(6) 0.015 0.424 0.000 0.062 0.001 0.443 1.050 4.8.2 L7 77.5-71.75 0.015 0.470 0.000 0.062 0.001 0.489 1.050 4.8.2 (7) L8 71.75-70.5 0.014 0.498 0.000 0.055 0.001 0.515 1.050 4.8.2 (8) L9 70.5-65.5(9) 0.014 0.584 0.000 0.055 0.001 0.601 1.050 4.8.2 L10 65.5-60.5 0.016 0.667 0.000 0.060 0.001 0.686 1.050 4.8.2 (10) L11 • 60.5-55.5 0.016 0.753 0.000 0.060 0.001 0.773 1.050 4.8.2 (11) L12 55.5-53.583 0.016 0.785 0.000 0.059 0.001 0.805 1.050 4.8.2 (12) L13 53.583- 0.010 0.451 0.000 0.036 0.001 0.463 1.050 4.8.2 53.333(13) L14 53.333- 0.010 0.492 0.000 0.036 0.001 0.504 1.050 4.8.2 48.333(14) L15 48.333- 0.010 0.538 0.000 0.036 0.000 0.549 1.050 4.8.2 43.333(15) L16 43.333-35.5 0.011 0.561 0.000 0.036 0.000 0.573 1.050 4.8.2 (16) L17 35.5-35(17) 0.014 0.756 0.000 0.043 0.001 0.772 1.050 4.8.2 L18 35-30(18) 0.014 0.800 0.000 0.043 0.001 0.815 1.050 4.8.2 L19 30-27.75 0.014 0.818 0.000 0.043 0.001 0.834 1.050 4.8.2 (19) L20 27.75-27.5 0.009 0.485 0.000 0.026 0.000 0.494 1.050 4.8.2 (20) L21 27.5-22.5 0.009 0.504 0.000 0.026 0.000 0.514 1.050 4.8.2 (21) L22 22.5-17.5 0.009 0.535 0.000 0.026 0.000 0.545 1.050 4.8.2 (22) L23 17.5-12.5 0.009 0.552 0.000 0.026 0.000 0.562 1.050 4.8.2 (23) L24 12.5-7.5(24) 0.010 0.574 0.000 0.026 0.000 0.585 1.050 4.8.2 L25 7.5-2.5(25) 0.010 0.596 0.000 0.026 0.000 0.607 1.050 4.8.2 L26 2.5-0(26) 0.010 0.602 0.000 0.026 0.000 0.613 1.050 4.8.2 Section Capacity Table Section Elevation Component Size Critical P oPaiow % Pass No. R Type Element K K Capacity Fail L1 107.5-102.5 Pole TP24.8008x24x0.2188 1 -3.25 967.74 4.0 Pass L2 102.5-97.5 Pole TP25.6017x24.8008x0.2188 2 -8.26 999.26 8.8 Pass L3 97.5-92.5 Pole TP26.4025x25.6017x0.2188 3 -8.71 1030.79 16.2 Pass L4 92.5-87.5 Pole TP27.2034x26.4025x0.2188 4 -12.15 1062.32 23.9 Pass L5 87.5-82.5 Pole TP28.0042x27.2034x0.2188 5 -12.66 1093.85 33.0 Pass L6 82.5-77.5 Pole TP28.805x28.0042x0.2188 6 -16.23 1125.37 42.2 Pass L7 77.5-71.75 Pole TP29.726x28.805x0.2188 7 -16.48 1137.98 46.6 Pass L8 71.75-70.5 Pole TP29:4886x28.6879x0.25 8 -17.45 1315.49 49.0 Pass L9 70.5-65.5 Pole TP30.2894x29.4886x0.25 9 -18.16 1351.52 57.3 Pass L10 65.5-60.5 Pole TP31.0902x30.2894x0.25 10 -20.73 1387.54 65.3 Pass 1-11 60.5-55.5 Pole TP31.8909x31.0902x0.25 11 -21.56 1423.57 73.6 Pass L12 55.5-53.583 Pole TP32.1979x31.8909x0.25 12 -21.87 1437.39 76.6 Pass L13 53.583-53.333 Pole TP32.238x32.1979x0.4125 13 -21.96 2362.59 44.1 Pass L14 53.333-48.333 Pole TP33.0388x32.238x0.4125 14 -23.14 2422.03 48.0 Pass L15 48.333-43.333 Pole TP33.8395x33.0388x0.4063 15 -24.36 2444.35 52.3 Pass L16 43.333-35.5 Pole TP35.094x33.8395x0.4063 16 -25.18 2483.37 54.6 Pass L17 35.5-35 Pole TP34.6741x33.87330.3125 17 -27.00 2093.51 73.5 Pass L18 35-30 Pole TP35.475x34.67410.3125 18 -28.06 2142.30 77.6 Pass L19 30-27.75 Pole TP35.8354x35.475x0.3125 19 -28.55 2164.26 79.4 Pass tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis i CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 39 Section Elevation Component Size Critical I P OP.„— % Pass No. ft Type Element K K Capacity Fail L20 27.75-27.5 Pole TP35.8754x35.8354x0.5125 20 ; -28.64 3533.41 47.0 Pass L21 27.5-22.5 Pole TP36.6762x35.8754x0.5125 21 i -30.17 3613.43 48.9 Pass L22 22.5-17.5 Pole TP37.4771x36.6762x0.5 22 -31.72 3604.58 51.9 Pass L23 17.5-12.5 Pole TP38.2779x37.4771x0.5 23 -33.30 3682.64 53.5 Pass L24 12.5-7.5 Pole TP39.0787x38.2779x0.4938 24 -34.90 3714.30 55.7 Pass L25 7.5-2.5 Pole TP39.8796x39.07870.4875 25 -36.52 3744.00 57.8 Pass L26 2.5-0 Pole TP40.28x39.87964.4875 26 -37.34 3782.06 58.4 Pass Summary Pole(1-19) 79.4 Pass RATING= 79.4 Pass *NOTE:Above stress ratios for reinforced sections are approximate. More exact calculations are presented in Appendix C. tnxTower Report-version 8.1.1.0 April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 40 APPENDIX B BASE LEVEL DRAWING tnxTower Report-version 8.1.1.0 0 (OTHER CONSIDERED EQUIPMENT) (12) 7/8'TO 78 FT LEVEL (3) 1-1/4"TO 78 FT LEVEL (PROPOSED EQUIPMENT CONFIGURATION) (1) 1-3/8-TO 88 FT LEVEL (OTHER CONSIDERED EQUIPMENT) 4) 1-1/4'TO 107 FT LEVEL (OTHER CONSIDERED EQUIPMENT) (6) 7/8"TO 61 FT LEVEL (2) 1-5/8- TO 61 FT LEVEL (OTHER CONSIDERED EQUIPMENT-IN CONDUIT) / (1) 3/8-TO 98 FT LEVEL / \\ (2) 7/8'TO 98 FT LEVEL / (OTHER CONSIDERED EQUIPMENT) (3) 3/8-TO 98 FT LEVEL / \ \ (2) 3/4'TO 98 FT LEVEL / (12) 1-5/8'TO 98 FT LEVEL 04 01 02 ' f • (OTHER CONSIDERED EQUIPMENT) (1) 1/2'TO TOWER LIGHTING `-CLIMBING PEGS W/ SAFETY CLIMB April 11, 2022 107.5 Ft Monopole Tower Structural Analysis CCI BU No 843211 Project Number 2081886, Order 549093, Revision 2 Page 41 APPENDIX C ADDITIONAL CALCULATIONS Program Version 8.1.1.0-6/3/2021 File://netapp4/cad/Structural Work Area/840000-849999/843211/WO 2081886-SA/ReporU843211.eri tnxTower Report-version 8.1.1.0 CUP@9Q per TIA-222-H Site BU: 843211 CROWN Work Order: 2081886 .z,.o CASTLE Pole Geometry Copyright©2019 Crown Castle Pole Height Above Section Length Lap Splice Length Top Diameter Bottom Diameter Bend,Radius Base(ft) (ft) (ft) Number of Sides WaIlThickness(in)(in) (in) (in) Pole Material 1 107.5 35.75 3.75 18 24 29.726 0.21875 Auto A607-60 2 75.5 40 4.5 18 28.69 35.094 0.25 Auto A607-60 3 40 40 0 18 33.87 40.28 0.3125 Auto A607-65 Reinforcement Configuration Bottom Effective Top Effective Elevation(ft) Elevation(ft) Type Model Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 0 27.75 plate CCI-SFP-065125 3 _ 2 27.75 53.583 plate CCI-SFP-050125 3 _ 3 4 5 6 7 8 9 10 Reinforcement Details Gross - Bottom Top Pole Face to Bottom Termination Net Area Bolt Hole Size Reinforcement B(in) H(in) Area Termination Top Termination Type Termination Lu(in) (inz) Centroid(in) Type Length(in) Length(in) (int) (in) Material 1 6.5 1.25 8.125 0.625 PC 8.8-M20(100) 33 PC 8.8-M20(100) 33.000 19.000 6.563 1.1875 A572-65 2 5 1.25 6.25 0.625 PC 8.8-M20(100) 24 PC 8.8-M20(100) 24.000 23.000 4.688 1.1875 A572-65 Mpole-version 4.5.7 Page 1 Analysis Date:2/17/2022 TNX Geometry Input Increment(ft): I 5 I Export to INX Lap Splice Length Bottom Diameter Tapered Pole Weight Section Height(ft) Section Length(ft) (ft) Number of Sides Top Diameter(in) (in) Wall Thickness(in) Grade Multiplier 1 107.5 - 102.5 5 - - 18 24.000 24:801 0.21875 A607.60-- 1.000 2 102.5 "97.5'• 5 18 24.801 -25.602 6.21875 A607-60 1.000 ._- 8 97.5: = 92.5 5 18 25.602 26:403 0.21875 A607-60 1.000 4 92,5 87:5 - 5'' - 18 26.403' 27.203 0.21875 A607-60 1.000 51 87.5 - 82.5 5- 18 27.203 28.004 - -0.21875 A607-60- 1.000 6 82.5 - 77:5--- -5 - 18 28.004- 28.805 - 0.21875 A607-60-- 7 77.5, = 75.5 5.75 3.75 - 18 28.805 29:725 0.21875 A607-60 1.000 8 75.5 - 70.5 518 28.688 29.489 0.25_ - A607-60 1.000_ 9 70.5 - 65:5 5 - 18 29.489 30:289 .0.2S A607-60 -1.000 10 - 65.5 - 60.5 5 - - _ 18 30.289 31.090- • 0.25 A607-60 1.000 ' 11 60.5- - 555 - 5 18 31.090 31.891 0.25 A607-60 1.000 12 55.5 53.583 1.917 _ 18' - 31.891 - 32.198' 6.25 'A607-60 1.000 13 53.583 = "53:333- 0.25 18 32.198 32.238' 0.4125 - A607-60 1.059 - 14 53.333 - .48.333- .5 18 32.238' 33.039' 0.4125 A607-60- - 1.048---- 15 48.333 - 43333 5 18 33.039' 33.840 0.40625 A607-60 - 1.053 - 16 43.333 - 40. 7.833 4.5 18 33.840 - 35.094 0.40625 -A607-60 1.046 17 '-40 - -35 .5 18 - -33.873 -34:674 - 0.3125 A607-65 '1.000 18 35 - .30 5 -- 18 34.674 35.475 6.3125. -A607-65 - 1.000 19 - 30, - 27.75 2.25 18 - 35.475 35:835 - 0.3125 A607-65 1.000 20 27.75 - 27.5 0.25 - 18 _ 35.835 35.875 0.5125 - A607-65 1.637 21 27.5 - 22:5 5 - 18 35.875 -36.676,' 0.5125 A607-65 1.027 22 22.5 - 17.5 5 ' ' 18 - 36.676 37.477 _ 0.5 A607-65 1.044 -_ 23 U.S. - 12:5 5 - - 18 - 37.477 38.278 0.5 A607-65 1.035 24 12.5 - 7.5 S' 18 _ 38.278 39.079 0.49375 _ A607-65 _ 1.039 251 7.5 - 2.5 5 16 39.079 39:880 - - -0.4875 A607-65 1.044 26 ..2.5 -. .0 -.2.5 - . - 18 .. 39.880 . .40.280. ..0.4875 - .A607-65 1.040.'. Mpole-version 4.5.7 Page 2 Analysis Date: 2/17/2022 TNX Section Forces Increment(ft): 9 5 I TNX Output Mux (kip- Section Height(ft) p„ (K) ft) V. (K) 1 107.5 102.5 3.25 21.75 4.52 2 102.5 - 97.5 8.26 49.45 10.29 3 97.5 - 92.5 8.71 102.02 10.74 4 92,5 87.5. 12.15 158.55 14.85 5 87.5 82.5 12.66 233.89 15.29 6 82.5 - 77.5 16.23 313.51 19.93 7 77:5 - 75.5 16.48 353.53 20.10 8 75.5 - 70.5 17.45 455.18 20.57 9 -70.5 65.5 18.16 559.23 21.13 10 - :65.5' - 60.5 20.73 667.27 23.86 11 60.5 - 55.5 21.56 787.38 24.23 12 55.:5 - 53.583 21.87 833.91 24.38 13 53.583 - 53.333 21.96 840.00 24.38 14 53:333 - '48.333 23.14 962.88 24.81 r16 48.333 - 43.333- 24.36 1087.80 25.21 - 43.333 - 40. 25.18 1172.18 25.47 40 35 27.00 1300.56 25.91 35 - 30 28.06 1430.75 26.22 19 30 - 27.75 28.55 1489.82 26.35 20 27.75 - 27.5 28.64 1496.40 26.35 21 .- 27.5 22.5 30.17 1628.95 26.71 f 22 22.5' 17:5 31.72 1763.17 27.03 23 17.5 - 12.5 33.30 1898.92 27.32 24 - - 12.5 - 7.5 34.90 2036.11 27.61 25 7.5- - 2.5 36.52 2174.70 27.89 26 2.5• - 0• 37.34 2244.51 28.03 CClpole-version 4.5.7 Page 3 Analysis Date: 2/17/2022 Analysis Results Elevation(ft) Co poenent Size Critical Element %Capacity Pass/Fail 107.5-102.5 Pole TP24.801x24x0.2188 Pole 4.0% WPass102.5-97.5 Pole TP25.602x24.801 x0.2188 Pole 8.7%97.5-92.5 Pole TP26.403x25.602x0.2188 Pole 16.2%p92.5-87.5 Pole TP27.203x26.403x0.2188 Pole 23.9% 87.5-82.5 Pole TP28.004x27.203x0.2188 Pole 33.0% Pass 82.5-77.5 Pole TP28.805x28.004x0.2188 Pole 42.20 ass 77.5-75.5 Pole TP29.726x28.805x0.2188 Pole 46.60 Pass 75.5-70.5 Pole TP29.489x28.6880.25 Pole 49.0% Pass 70.5-65.5 Pole TP30.289x29.489x0.25 Pole I 57.3% Pass 65.5-60.5 Pole TP31.09x30.289x0.25 Pole 65.3% Pass 60.5-55.5 Pole TP31.891x31.09x0.25 Pole 73.6% Pass 55.5-53.58 Pole TP32.198x31.8914.25 Pole 76.6% Pass 53.58-53.33 Pole+Reinf. TP32.238x32.198x0.4125 Reinf.2 Tension Rupture 63.4% Pass 53.33-48.33 Pole+Reinf. TP33.039x32.2380.4125 Reinf.2 Tension Rupture 69.8% Pass 48.33-43.33 Pole+Reinf. TP33.84x33.039x0.4063 Reinf.2 Tension Rupture 75.9% Pass 43.33-40 Pole+Reinf. TP35.094x33.84x0.4063 Reinf.2 Tension Rupture 79.7% Pass 40-35 Pole TP34.674x33.873x0.3125 Pole 73.5% Pass 35-30 Pole TP35.475x34.674x0.3125 Pole 77.6% Pass 0-27.75 Pole TP35.835x35.475x0.3125 Pole 79.4% Pass 27.75-27.5 Pole+Reinf. TP35.875x35.835x0.5125 Reinf.1 Tension Rupture 69.4% Pass 27.5-22.5 Pole+Reinf. TP36.676x35.875x0.5125 Reinf. 1 Tension Rupture 72.9% Pass 22.5-1 .5 f Pole+Reinf. TP37.477x36.676x0.5 Reinf.1 Tension Rupture 76.2% Pass 17.5-12.5 Pole+Reinf. TP38.278x37.4770.5 Reinf.1 Tension Rupture 79.3% Pass 12.5-7.5 Pole+Reinf. TP39.079x38.278x0.4938 Reinf.1 Tension Rupture 82.2% Pass 7.5-2.5 Pole+Reinf. TP39.88x39.079x0.4875 Reinf.1 Tension Rupture 84.9% Pass 2.5-0 Pole+Reinf. TP40.28x39.88x0.4875 Reinf.1 Tension Rupture 86.2% Pass Summary Pole 79.4% Pass Reinforcement 86.2% Pass Overall 86.2% Pass Mpole-version 4.5.7 Page 4 Analysis Date: 2/17/2022 Additional Calculations Section Moment of Inertia(in 4) Area(int) %Capacity* Elevation(ft) Pole Reinf. Total Pole Reinf. Total Pole RS R2 107.5-102.5 1303 n/a 1303 17.07 n/a 17.07 4.0% 102.5-97.5 1434 n/a 1434 17.62 n/a 17.62 8.7% 97.5-92.5 1574 n/a 1574 18.18 n/a 18.18 16.2% 92.5-87.5 1723 n/a 1723 18.74 1 n/a 18.74 23.9% 87.5-82.5 1881 n/a 1881 19.29 n/a 19.29 33.0% 82.5-77.5 2048 n/a 2048 19.85 n/a 19.85 42.2% 77.5-75.5 2118 n/a 2118 20.07 n/a 20.07 46.6% 75.5-70.5 2505 n/a 2505 23.20 n/a 23.20 49.0% 70.5-65.5 2716 n/a 2716 23.84 n/a 23.84 57.3% 65.5-60.5 2940 n/a 2940 24.47 n/a 24.47 65.3% 60.5-55.5 3175 n/a 3175 25.11 n/a 25.11 73.6% 55.5-53.58 3268 n/a 3268 25.35 n/a 25.35 76.6% 53.58-53.33 3293 2098 5391 25.38 18.75 44.13 48.7% 63.4% 53.33-48.33 3546 2199 5745 26.02 18.75 44.77 54.1% 69.8% 48.33-43.33 3812 2302 6114 26.65 18.75 45.40 59.2% 75.9% 43.33-40 3996 2372 6369 27.08 18.75 45.83 62.5% 79.7% 40-35 . 5082 n/a 5082 34.08 n/a 34.08 73.5% 35-30 5446 n/a 5446 34.88 n/a 34.88 77.6% 30-27.75 5615 n/a 5615 35.23 n/a 35.23 79.4% 27.75-27.5 5655 3368 9023 35.27 24.38 59.65 51.7% 69.4% 27.5-22.5 6047 3607 9653 36.07 24.38 60.44 54.0%1 72.9% 22.5-17.5 6454 3759 1 10213 36.86 24.38 61.24 56.8% 76.2% 17.5-12.5 6880 3915 10795 37.66 24.38 62.03 59.5% 703% 12.5-7.5 7324 4073 11397 38.45 24.38 62.82 62.0% 82.2% 7.5-2.5 7786 4235 12022 39.24 24.38 63.62 64.5% 84.9% 2.5-0 8025 4318 12342 39.64 24.38 64.02 1 65.7% 86.2% Note:Section capacity checked using 5 degree increments. Rating per TIA-222-H Section 15.5. CClpole-version 4.5.7 Page 5 Analysis Date: 2/17/2022 Monopole Base Plate Connection CROWN OC CASTLE BU# 843211 Site Name MATTITUCK Order# 549093 Rev 2 n 0' Analysis Considerations TIA-222 Revision H Grout Considered: No lar(in)l 1.5 Applied Load-, Moment(kip-ft) 2244.51 Axial Force(kips) 37.34 Shear Force(kips) 28.03 'TIA-222-H Section 15.5 Applied +o� CD Connection Properties Anchor Rod Data Anchor Rod Summary (units of kips,kip-in) (12)2-1/4"0 bolts(A615-75 N;Fy=75 ksi,Fu=100 ksi)on 47"BC Pu—t=187.73 (�Pn_t=243.75 Stress Rating Anchor Spacing:6 in Vu=2.34 4)Vn=149.1 73.4% Mu=n/a (tMn=n/a Pass Base Plate Data 46"W x 2.5"Plate(A572-55;Fy=55 ksi,Fu=70 ksi); Clip:8 in Base Plate Summary Max Stress(ksi): 42 (Flexural) Stiffener Data Allowable Stress(ksi): 49.5 N/A Stress Rating: 80.8% Pass Pole Data 40.28"x 0.4875"18-sided pole(A607-65;Fy=65 ksi,Fu=80 ksi) CClplate-Version 4.1.2 Analysis Date:2/17/2022 Drilled Pier Foundation CROWN "U" 843211 CASTLE Site Name:: MATTITUCK Order Number: 549093 Rev 2 TIA-222 Revison: H Check Limitation Tower Type: MonopoleApply TIA-222-H Section 15.5: r N/A AppliedAnalysis ReSLJltS Additional Longitudinal Rebar Loads Soil Lateral Check Compression Uplift Input Effective Depths(else Actual): Comp. U lift D,(ft from TOC)1 6.40 Shear Design Options Moment (kip-ft 2244.511 Soil Safety Factorl 1.52Check Shear alongDepth of Pier: Axial Force kis 37.35 Max Moment(kip-ft) 2403.26 Utilize Shear-Friction Methodolo Shear Force kis 281 Rating*1 83.2% Override Critical Depth] Soil Vertical Check Compression Uplift Go to Soil Calculations Material Properties Skin Friction(kips) 166.20 Concrete Strength,f'c 1 31 ksi End Bearing(kips) 318.09 Rebar Strength,F 60 ksi Weight of Concrete(kips) 109.42 Tie Yield Strength,F t:I 40 ksi Total Capacity(kips) 484.28 Axial(kips) 146.77 Pier Design Data Rebar&Pier Options Rating* 28.9% - Depthl 21 Ift Reinforced Concrete Flexure Compression Uplift Ext.Above Gradel 0.5 ft Embedded Pole Inputs Critical Depth(ft from TOC) 6.24 Pier Section 1 Belled Pier Inputs Critical Moment(kip-ft) 2403.03 From 0.5'above grade to 2l'below grade Critical Moment Capacity 3355.69 - Pier Diameter 6 ft Rating* 68.2% Rebar Quantity 16 Reinforced Concrete Shear Compression Uplift Rebar Size 11 Critical Depth(ft from TOC) 16.16 Clear Cover to Ties 4 in Critical Shear(kip)l 341.92 Tie Size 5 Critical Shear Capacityl 430.12 Tie Spacing 18 in Rating*1 75.7% Structural Foundation Rating*1 75.7% Soil Interaction Rating` 83.2% "Rating per TIA-222-H Section 15.5 Soil Profile Groundwater De th N/A I I #of Layers 1 3 Angle of Calculated Calculated Ultimate Skin Ultimate Skin Ult.Gross Top Thickness y:o i yoon«ot• Cohesion Ultimate Skin Ultimate Skin Friction Comp Bearing SPT Blow Layer Bottom(ft) Friction Friction Uplift Soil Type (ft) (ft) (pcf) (pcf) (ksf) Friction Comp Friction Uplift Override Capacity Count (degrees)(degrOverride(ksf) (ksf) (ksf) (ksf) (ksf) 1 0 4.167 4.167 100 150 0 0 0.000 0.000 0.00 0.00 Cohesionless 2 4.167 15 10.833 100 150 0 28 0.346 0.346 5 Cohesionless 31 151 21 61 1001 1501 01 301 1.3351 1.3351 15 121 Cohesionless Version 5.0.3 E ASCE 7 Hazards Report AMERICAN SOCIETY Of CML ENGINEERS Address: Standard: ASCE/SEI 7-16 Elevation: 2883 ft(NAVD 88) No Address at This Risk Category: 11 Latitude: 40.999386 Location Soil Class: D - Default(see Longitude: -72.511158 Section 11.4.3) �.> . 6,uleA1 IWna O gap l ''.r�• � t`ir, .�.�•,T� .ROS . �Z".• � � ,., , un,ll� r ` � f I / I� 4 :1 ��' '• I t 1i. ..Iliil l:iii Wind Results: Wind Speed: 128 Vmph 10-year MRI 76 Vmph 25-year MRI 87 Vmph 50-year MRI 99 Vmph 100-year MRI 106 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-113 and Figs. CC.2-1—CC.2-4, and Section 26.5.2 Date Accessed: Thu May 13 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings need not be protected against wind-borne debris. https://asce7hazardtool.online/ Page 1 of 3 Thu May 13 2021 E' AMERICAN SOCIETY OF CML ENGINEERS Seismic Site Soil Class: D- Default(see Section 11.4.3) Results: Ss 0.174 SD1 0.079 S, 0.049 TL 6 Fa 1.6 PGA : 0.094 F, 2.4 PGA m : 0.151 SMS 0.278 FPGA 1.6 SM1 0.118 le 1 SDS 0.185 C� 0.7 Seismic Design Category B 030 MCER Response Spectrum U0 Design Response Spectrum I • 018 025 • 016 t 020 * 0.14 0 12 0.15 ` • 010 00841 010 006 005 004 002 0 0 0 1 Sa(9)vs T(s) 4 5 6 7 0 1 4 5 6 ? Sa(9)vs T(s) 016 MCER Vertical Response Spectrum 011 Design Vertical Response Spectrum •.. 0.14 .•..» 0.10 ' 0.09 ..••M 0.12 ' 0.08 0.10 . 007 • 0.08 '. 0.06 • 006 '•••• 0-05 '.. 0.040.04 4 1 00 .04 •• ••••••••••..•.••••• 0.03 ' •••• 0.02 0.02 . ••'••••••'••••• 0 0.5 1.0 1.5 2.0 0 0.5 1.0 1.5 2.0 Sa(9)vs T(s) Sa(9)vs T(s) Data Accessed: Thu May 13 2021 Date Source: USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS. httos://asce7hazardtoo1.on1ine/ Page 2 of 3 Thu May 13 2021 ASCE* AMERICAN SOCIETY OF CML ENGINEMS Ice Results: Ice Thickness: 1.00 in. Concurrent Temperature: 15 F Gust Speed: 50 mph Data Source: Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Date Accessed: Thu May 13 2021 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience,for informational purposes only,and is provided"as is"and without warranties of any kind.The location data included herein has been obtained from information developed,produced,and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard.While ASCE has made every effort to use data obtained from reliable sources or methodologies,ASCE does not make any representations or warranties as to the accuracy,completeness,reliability, currency,or quality of any data provided herein.Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,relationship,or sponsorship of such third-party content by or from ASCE. ASCE does not intend,nor should anyone interpret,the results provided by this Tool to replace the sound judgment of a competent professional,having knowledge and experience in the appropriate field(s)of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool,you expressly assume all risks associated with your use.Under no circumstances shall ASCE or its officers,directors, employees,members,affiliates,or agents be liable to you or any other person for any direct,indirect,special,incidental,or consequential damages arising from or related to your use of,or reliance on,the Tool or any information obtained therein.To the fullest extent permitted by law,you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https:Hasce7hazardtool.online/ Page 3 of 3 Thu May 13 2021 Radio Frequency — Electromagnetic Energy (RF-EME) - Maximum Permissible Exposure (MPE) Study Report for Site ID: NYNYCO2191A Elij ah's Lane, Mattituck, NY 11952 Date: February 16, 2022 Prepared by: Henry Gultom Confidential and Proprietary 0 2021 DISH WIRELESS Site Report Summary Table Is Site Compliant with FCC Rules and Regulations? Yes Is Remediation Required? No Any Other Recommendation(s)? Table of Contents SiteReport Summary Table............................................................................................................ 1 1. Introduction and the Purpose of the Report................................................................................ 2 2. Site Data Description.................................................................................................................. 3 3. Analysis....................................................................................................................................... 6 3.1 Roof View study on the Ground Level...:.............................................................................. 6 3.1.1 FCC MPE Limits ........................................................................................................... 6 3.1.2 FCC 5%Rule................................................................................................................. 9 3.2 Signage Location Diagram ................................................................................................. 11 4. Conclusion................................................................................................................................ 12 5. Attachments .............................................................................................................................. 13 5.1 Attachment A...................................................................................................................... 13 5.2 Attachment B...................................................................................................................... 14 1 Confidential and Proprietary 0 2021 DISH WIRELESS 0 1 . Introduction and the Purpose of the Report This report addresses exposure to radio frequency electromagnetic fields in accordance with the FCC Rules and Regulations for all individuals, classified in two groups, "Occupational" and "General Public." All computer modeling and analytical methods have been performed in accordance with the FCC's Office of Engineering and Technology.Bulletin 65 ("OET Bulletin 65"), Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields, Edition 97-01,published August 1997. This document specifically addresses compliance of Dish's transmitting facilities independently and in relation to all collocated transmitting facilities,which together constitute the RF environment at the site. This report contains a detailed summary of the RF environment at the site including: • Theoretical MPE based on software modeling • Some pages of the construction drawing of the site The predictive software tool, RoofView,utilizes a cylindrical model that provides a spatially averaged power density that is calculated in 1 square foot increments (pixels). The composite RF fields are displayed as a percentage of the appropriate standard. Spatial-peak is the maximum RF energy, across the area of the human body(about six feet high), that an individual can be exposed to. This is considered the Full Body Peak (FBP). This level should be considered the highest level that is found in the area of interest. If during the evaluation of an area for exposure, there are no FBP exposures above the MPE being considered, the area is considered below the limits and requires no additional evaluation. Spatial-averaging: If, during the evaluation of an area for potential exposure, it is determined that there are areas where peak FBP levels exceed the MPE, then spatial-averaging is required. Spatial-averaging considers the complete area of the human body in the evaluation of exposure. If there is an area that RF fields are above the applicable MPE limit, then additional vertical measurements should be taken. This is done to understand the levels between the ground level and six feet high. The average of these vertical measurements is known as,the Spatial-averaged exposure,which is used to evaluate compliance with the MPE. The plots in Section 3 show the spatial average predicted power density levels in the reference plane indicated as a percentage of the General Public Limits. Please note that 100% of the General Public Limits corresponds to 20% of the Occupational Limits as shown in Section 5 Attachment A. 2 Confidential and Proprietary 0 2021 DISH WIRELESS 0 2. Site Data Description This is a Monopole/Stealth site with three sectors and the sketch below shows the section of the pole where the antennas are located. The data configuration for the site is also provided below. This report is based on the Final Stamped Construction Drawings dated 10/13/2021 (NYNYCO2191A FinalStampedCDs_20211013093512). PRCmm DISH**"LLA.Mm" MP I PER Sara+,7M 3) PROPOS DWI**M LLA RAH:(TIP 2 m 9B IM Im OJ MR=x511 WN9n LLA CF 1 PEA SECIg � Al EXOMNO Y.QNC.PCLE •;.O•QV PROPOSED 091 WM- 01 �,,� r� LLC.DVP OMD6 PROP�D DP31 Wb _ _ a usvc. -oR6'1 DT Dish Monopole Top View. Other carriers are not shown for picture clarity 3 Confidential and Proprietary©2021 DISH WIRELESS 0 EMSTM.PANEL AN1>rVNAS' RAO CENIEi 0 110-8"ACL' EX"NC MONOPOLE TOP'EL R IV--V EYISTING'PANEL ANTENNAS'. P.AD'CENTER 0'107'-6"'AGL ED . EXI5ING PANEL.ANTENNAS RAD CENTER 0 98'-9'AGL. _ (ai PaasoSED a:xf wiww..,:►.i.a_ua;ENTiAs ralo"�ona� o'�ii�-gr Di-WG...PANEL ANTENNAS RAO CENTER a BI r3 ACL.-$ E%ISTNG PANEL.ANTENNAS HAD-CENTER A D9'-G"AGL' . ((1)PROPOSED DISH WM1an.1.LC.. /�— RI) CAM ROWED OtMIDEPOLE Ew57Ir;G i+aNa�a� PROPOSED,DISH WMen.L.LC.- EIONPMENT ON PROPOSE:57EEL PLATFORM PROPOS®.DISH WWW LLA PROPOS®'GISH WM en LLC ICE BRUICE CPS tiNil' EXIS71NIG E'hTRY PORT ENIMNG MONOPOLE BO7T91.4'EL AGL Monopole Elevation View. Antenna Carrier from top to bottom: Verizon, Sprint, Dish, AT&T, TMobile 4 Confidential and Proprietary©2021 DISH WIRELESS 0 _,Ant MHz Input. Calc ft ft ftftd8d _BWdth -ON Num ID Nanie` Fr64 Powe:iPower _Md Model- Xs Y. Z• AWA- Galn P6Dit 1a` 11 Dish 1A 5G 600 600 120 120 JMA MX08FRO665-21 23 26 85 6 11.5 65'30 ON- ,2 Dish 1A 5G AWS 2100 320 320 JMA MX08FRO665-21 23 26 85 6 16.4 65;30 ONS 3 Dish 2B 5G 600 600 120 120 JMA MX08FRO665-21 24 15 85 6 11.5 65;150 ONe '4 Dish 2B 5G AWS 2100 320 320 JMA MXOBFRO665-21 24 15 85 6 16.4 65;150 ON- 5.Dish 3C 5G600 600 120 120 JMA MXOBFRO665-21 14 20 85 6 11.5 65;270 ON• _6.Dish 3C 5G AWS 2100 320 320 JMA NIX08FROS65-21 141 20 85 61 16.4 65'270 ON• A Verizon 1A LTE 850 60 60 Ericsson AIR32 82A/B66Aa 24 24 104 4.9 17 65;60 ON- JS Verizon 1A LTE 1900 60 60 Ericsson AIR32 B2AIB66Aa 24 24 104 4.9 17 65;60 -ON- .9 Verizon 2A LTE 2100 120 120 Ericsson AIR21 B2A/B4P 24 24 104 4.5 17.8 65;60 ON- 10 Verizon 3A 5G 600 120 120 Ericsson AIR32 B2AIB66Aa 24 24 104 4.9 18 65;60 ON- '11 Verizon 18_ LTE 850 60 60 Ericsson AIR32 B2A/B66Aa 24 17 104 4.9 17 65'180 ON- 1'2 Verizon 1B LTE 1900 60 60 Ericsson AIR32 B2AIB66Aa 24 171 104 4.9 17 65;180 ON+ 13 Verizon 2B LTE 1 2100 1201 1201 Ericsson AIR21 82AIB4P 24 17 1041 4.5 17.8 65180 1 OW 14 Verizon 3B 5G 600 120 120 Ericsson AIR32 B2AIB66Aa 24 17 104 4.9 18 65;180 OW 15,Verizon 1C LTE 850 60 60 Ericsson AIR32 B2Ai866Aa 17 `20 104 4.9 17 65;300 ON• 16 Verizon 1C LTE 1900 60 60 Ericsson AIR32 B2A(866Aa 17 20 104 4.9 17 65.300 ON- 17 Verizon 2C LTE 2100 120 120 Ericsson AIR21 B2AI84P 17 20 104 4.5 17.8 65;300 ON- 18 Verizon 3C 5G 600 120 120 Ericsson AIR32 82Ai866Aa 17 20 104 4.9 18 65;300 -ON- 19 S rint1A LTE 650 60 60 Ericsson AIR32 B2A/B66Aa 24 24 95 4.9 17 6560 -ONm 20 Sprint 1A LTE 1900 60 60 Ericsson AIR32 82A/B66Aa 24 24 95 4.9 17 65;60 ON- -- Sprint 2A LTE 2100 120 120 Ericsson AIR21 B2A/B4P 24 24 95 4.5 17.8 65.60 ON- '22 Sprint 3A 5G 600 120 120 Ericsson AIR32 B2A/866Ae 24 24 95 4.9 18 65.60 ON- - Sprint 18 LTE 860 60 60 Ericsson AIR32 B2A/B66Aa 24 17 95 4.9 17 65.180 ON- '94 Sprint 18 LTE 1900 60 60 Ericsson AIR32 82NMAa 24 17 85 4.9 17 65.180 ON- %25 S rint 2B LTE 2100 120 120 Ericsson AIR21 M/134P 24 17 95 4.5 17.8 65.160 -ON- "26 Sprint 38 5G 600 120 120 Ericsson AiR32 B2AIBBBAa 24 17 95 4.9 18 65;180 •ONi ,27 Sprint 1C LTE 850 60 60 Ericsson AIR32 B2AI866Aa 17 20 85 4.9 17165;300 ON- 14 Sprint 1C LTE 1900 60 60 Ericsson AIR32 82AIS66Aa 17 20 95 4.9 17165:300 ON- 29 Sprint 2C LTE 2100 120 120 Ericsson AIR21 B2A/B4P 17 20 95 4.5 17.8 65;300 ON- 30 Sprint X 5G 600 120 120 Ericsson AIR32 B2AIB66Aa 17 20 95 4.9 18 65;300 ON- 31;TMobile 1A LTE 850 60 60 Ericsson AIR32 82AIB66Aa 24 24 62 4.9 17 65.50 ON- :..32 TMobile 1A LTE 1900 60 80 Ericsson AIR32 82Ai866Aa 24 24 62 4.9 1765'.60 ON4 33 TMoblle 2A LTE 2100 120 120 Ericsson AIR21 82AVP 24 24 62 4.6 17.8 65;50 ON- 34 TMoblle 3A 50 600 1201 120 Ericsson 1AIR32 B2AIB66Aa 24 24 62 4.9 18 65;50 ON- 35 TMobile 1 B ILTE 850 60 60 Ericsson AIR32 B2A/B66Aa 24 17 62 4.9 17 65.170 ON- 516 Mobile 1B LTE I 1900 60 60 Ericsson AIR32 B2NS66Aa 24 17 62 4.9 17 65.170 :ON- 37 TMoblle 2B LTE 2100 120 120 Ericsson AIR21 B2AI84P 24 17 62 4.5 17.8 65;170 ON- .38 TMobile 38 5G 600 120 120 Ericsson AIR32 82AI866Aa 24 17 62 4.9 18 65;170 ON- '30 TMoblle 10 LTE 850 60 60 Ericsson AIR32 82A/866Aa 17 20 62 4.9 17 85.290 ON- '40 TMobile 10 LTE 1900 60 60 Ericsson AIR32132AMWAa J7 20 62 4.9 17 65 290 ON- 49,TMoblie 2C LTE 2100 1201 120 Ericsson 1AIR21 B2A/B4P 17 20 62 4.5 17,8165:290 ON- 42 1 Mobile 3C 5G 600 120 120 Ericsson AIR32 82A/B66Ae 171 20 '621 4.9 18 65;290 -ON, .43 ATT 1A LTE 850 60 60 Ericsson AIR32 82A/866Aa 16 24 79 4.9 17 65.30 ON- 44 ATT to LTE 1900 60 60 Ericsson AIR32 B2AI866Aa 16 24 79 4.9 17 65.30 1 ON- ".4$ATT 2A LTE 2100 120 120 Ericsson AIR21 B2A/B4P 16 - 24 79 4.6 17.8 65;30 ON• .45 ATT 3A 5G 600 120 120 Ericsson AIR32 B2AIB66Aa 16 24 79 4.9 16 65.30 ONS 47 ATT 1B LTE 850 60 60 Ericsson AIR32 B2WB66Aa 25 20 79 4.9 17 65;160 ON- 48 ATT 1B LTE 1900 60 60 Ericsson AIR32 82AI866Aa 25 20 79 4.9 17 65.150 ON- -'k49 ATT 2B LTE 2100 120 120 Ericsson AIR21 82AI84P 25 201 79 4.5 17.8 85.150 ON- 150 ATT 38 5G 600 120 120 Ericsson AIR32 B2AIB66Aa 25 20 79 4.9 18 65.150 ONS 51-ATT 1C LTE 860 60 60 Ericsson AIR32 B2AIB66Aa 17 15 79 4.9 17 65270 ON, ,52 ATT 1C LTE 1900 60 60 Ericsson AIR32 B2A/868Aa 17 15 79 4.9 17 65.270 ON• M ATT 2C LTE 2100 120 120 Ericsson AIR21 B2A/B4P 17 15 79 4.5 17.8 65;270 ON. _ -5.4 ATT 3C 5G 600 120 120 Ericsson AIR32 B2A 866Aa 17 15 79 4.9 18 65;270' ON- Antenna Table 5 Confidential and Proprietary©2021 DISH WIRELESS 0 3. Analysis Roof View®uses both `Near Field' and `Far Field' approaches to calculate the RF Energy and determines the percentages of electromagnetic exposure-as defined by the aforementioned. bulletin. RoofView® is Dish' approved roof top and monopole prediction software. An analysis of this site was completed to establish safe working distances for the Public utilizing guidelines set forth by the Federal Communications Commission(FCC) with regards to maximum human exposure limits; this has been accomplished by the use of predictive modeling software. The modeling predictions have been done using 100% transmitter duty cycle. This will predict a worst case scenario for safety reasons. The purpose of this study is to determine safe distances for the general public from the antenna arrays and to bring the site into FCC/OSHA compliance. The predictive software tool utilizes a cylindrical model that provides spatially averaged power density that is calculated in 1 square foot increments (pixels). The composite RF fields are displayed as a percentage of the appropriate standard. These are the predicted software plots of the Maximum Permissible Exposure (MPE). This site has been analyzed using the General public/uncontrolled exposure limits and Occupational/controlled exposure limits. A representation of the area around the pole is shown. NOTE: The plot grids are in 10 feet increments. Individual pixels are 1 foot square. 3.1 RooMew study on the.Ground Level 3.1.1 FCC MPE Limits For Limits see Attachment A. Threshold definitions (see Attachment B for Signs): GREEN <= 100% of FCC Public Standards BLUE >100%to<=500% of FCC Public Standards YELLOW >500%to<=5000% of FCC Public Standards RED >5000% of FCC Public Standards The chart below shows a summary of the exposures on the ground level, in 1 square foot increments for Public Limits MPE. The highest exposure occurs at a point directly in front of the direction of propagation of the antenna. 6 Confidential and Proprietary©2021 DISH WIRELESS Exposure on the Ground Level—with Overlay. The picture above shows that RF Exposure on the ground level does not exceed FCC Public Standard Limit. 7 Confidential and Proprietary 2021 DISH WIRELESS 0 Statistical Summary X Statistical Summary __ Done % p Copy Data 1600 100.00 p/o of Total R OF Area L 0 - 00-0 - - 1600 p/o of Se ecte Area 100.0 - 500.0 0.00' 0% of Selecte Area 500.0 - 5,OOC 0.00 0/o of Selecte Area �> 51 )00.0 � _ 0__ 0.0 10 of Selecte Area Roof Area 1600 sq. ft. Max %MPE 15.3 % Min %MPE 0 % U3111Y Iyc;ol/ l al OPOLIal MV IVIIIJU) With FCC 1997 Public Standard HELP Statistical Exposure Distribution. There is no EM exposure (>100%)on the ground level. Confidential and Proprietary`.; 2021 DISH WIRELESS 0 3.1.2 FCC 5% Rule For Limits see Attachment A. PURPLE > 5%of FCC Public Standards The chart below shows the area where Dish's signal contributions are 5% or more of the Public MPE Limit. This is as per the FCC's OET Bulletin 65,which states: "The rules adopted by the FCC specify that, in general, at multiple transmitter sites, actions necessary to bring the area into compliance with the guidelines are the shared responsibility of all licensees whose transmitters produce field strengths or power density levels at the area in question in excess of 5% of the exposure limit (in terms of power density or the square of the electric or magnetic field strength) applicable to their particular transmitter." Dish EM Exposure on the Ground Level is less than 5% (all green) 9 Confidential and Proprietary 0 2021 DISH WIRELESS 0 Statistical Summary X Statistical Summary ____ °°nePF _ l o Copy Data 1600 100.00 % of Total R OF Area --5.0 1600 % o Se ecte Area 5.0 0 00�; % of Selecte Area of Selecte Area __._...___.__-_ - -_____-_-No__of Selec Area Roof Area 1600 sq. ft. Max %MPE 4.9 Min %MPE 0 0/0 With FCC 1997 Public Standard HELP Statistical Exposure Distribution on 5% Threshold 10 Confidential and Proprietary 0 2021 DISH WIRELESS 0 3.2 Signage Location Diagram EV P.n'6 Pr1�ANTENN/5 -700 CENTER 9110-8"ACL J,, _... __ E%Ei71NG MONOPOLE j TOP Fl,O I07'-8'ACL 0451 O PMEL ANIEY�NAS�� RAO CENTER O 107'-8i* CX1511NC PANEL AN1f?lNAi RIO CENTER 0 9A-0"AGL (7)PROPOSED DISH NOMME Ur-AN>)pOM{ MING PAKa ANTENNAS DOSING PANEL AN1P`HNAE RAD CENTT 0 64: ACL I (1)PROPOSED CISH WYdm LAA. HYBRID CABLE ROUTED OUM POLL -EXISTING MONOPOLE IMIO/OOm CISH wYdm LLC. =PM■r ON PROPOSED STEEL KAl'ONII PROPOSED DISH Wnlm LLC. ICE BRIDGE PIIOPOW DISH Wtdm LLC. OPS IAAT E>t1511,4 ENIRY PORT •�Y:s� EXISTING MONOPOLE BTO O11 1L O 6"ACL Signage Location at the Pole Color Description: Notice Sign; ❑ Caution Sign; ❑ Warning Sign; Information Sign; — Chain Link 11 Confidential and Proprietary 0 2021 DISH WIRELESS 4. Conclusion The charts above show a summary of the exposures on the ground level, in 1 square foot increments. The predicted software analysis performed with Roof View has shown that Dish transmitter equipment located on this pole does not exceed the maximum permissible exposure levels for the FCC Public or FCC Occupational standards on the ground level. This site is compliant with FCC Guidelines as designed. These results assume that the equipment uses the maximum transmitter capacity with 100% duty cycle and therefore are the worst case scenarios. Other operators' antenna locations have been included in the study to give a composite value. 12 Confidential and Proprietary 0 2021 DISH WIRELESS 0 5. Attachments 5.1 Attachment A - LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) A 4j'ifi is fir q0" ' �t!6na!/�gri#rolled . .. .) P I_paslare. Freouer ty: Eler tc�lefd ft401C et€C C aefd pts tier enslty' :,4uera 3e� Time , ar a teen (t), $tre th (10 1E(a► 1HIZ of -1842 ;'304dil.. .. X1,4 ,0: 1,0, I{.3c0boo I>ants;. has+ eea°al.rls�pi�tl�tion� n�:u��°���ed �epasctre : r�tl�ie�lc+j Eledr-1c t field 'N1atgr�etic Ne'ld pot�t�®r Density Averaging, 7 M6 iftge or � 10- Wrnl Om* 1).' (fin€nes) 3aQf� 100;CDt1tD .. .0 1. 36 f frequency In Wz_llplane-waue:equlvalent poWer.d4ds'sty N&e f Oeclip.aitl6J 4111 ©h6alled ins mppty rn € aat�ans In hj �5ons are cpo d as a cpnsegqu qce of their emptoym rpt prau dO those Pel ons, se:fully 'of the.p�tent�'I lb ezp slice apd can exertisecontrol Quer the�r;ex pr'e, t_'aTts:far. `occu ton lj'c ntrollEd exposure also"apply ri situ tions When ars In'dWidu l Is tcarrsier t t!'ugta locat en�v ire c�Cci laationalJcontxa9led t sts�pp9y ftrrriri ed h or she as mac 'ay4 are Of the potentG 1, pc ex l}Sdf . NOTS 2i Cenerat papu6 on torrcontrolled exposures appG:in situations in Wi 16 'the,general"Oublic r*,tre expdsad;-or'1in 7ihfch persons that ark exposed as a consequence of&v enployipegt rgay not be-fully ware of"the p6tential€vr exposure can n66e?ier.dse-Cfitrol6Wt.thbtr,eioosdt' . 13 Confidential and Proprietary©2021 DISH WIRELESS 0 5.2 Attachment B 770 NOTICE signs alert persons that they are attempting to access an area in which RF exposure levels could potentially exceed the General Population/Uncontrolled MPE. This sign must be posted in a visible area at each entrance to the site and at localized areas (in conjunction with any required barriers) when the RFE survey indicates that exposure levels in any area of the rooftop or on the ground are equal to or exceed the "POW�*zoo"Ow u General Population/Uncontrolled MPE. y.Y...I puWl.-p—YY"L .r wrYYY r n.r•.a.... ACAUTION CAUTION signs alert persons that they are attempting to enter an area in which RF exposure may exceed the Occupational/Controlled MPE. This sign must be posted in a visible area at each entrance to the site and at localized areas (in conjunction with any required barriers)when the RFE survey indicates that exposure levels in any area of the rooftop or on the ground are equal to or exceed so""NN point the Occupational/Controlled MPE. INHe hYgYYYYy flYN.N MIY YIN nl.y.tcwM IC6 tYIM M IMHnYn .Yp..Ytw P.iw.•AM...y Y....r..IY..M Yr..rY1M.M wMMMY r n.l. N.YYwMt...Y..r..r. 4WARNING WARNING signs alert persons that they are attempting to enter an area in which the °� RF exposure may exceed the Occupational/Controlled MPE by a factor of 10 or greater. This sign must be posted in a visible area at each entrance to the site and at localized areas (in conjunction with any required barriers)where this level of a.""tM.paha exposure might occur. INH.1,q,, .y U.NY at W.YNY Y y-d FOO rY1a M kwomm YYpOYYf.. Y pdW w M w"rY r r.a.t.prw. wwYM....Y.M.r.M r MrrM rl.rr. INFORMATION INFORMATION signs shall be posted at all FICIN AMi1aMY1� � =trans�mltdng access points to a site. They may provide O oaTlEor [Ri0lOiliaN�JM POINT to an contact information for an questions or ©Won MON ngantennas. concerns regarding the site. This type of sign STAY SACKAMIMAlOFIFM ""°`"'"'" also includes a Spanish translated version. an."I.lon..n.�s h 14 Confidential and Proprietary 0 2021 DISH WIRELESS Derek Picinic From: LG Rightmyer Sent: Tuesday,June 21, 2022 7:39 PM To: LG Rightmyer Subject: FW: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191 A From: LG Rightmyer Sent: Friday,June 3,202211:55 AM To: Ben Evans<ben@cityscapegov.com> Subject: FW: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191A Good Morning Ben, We have been reaching out to the town and Mike Verity for updates on this site. We are not getting any response or update. Do you have any additional information of contact we can try? From: LG Rightmyer Sent: Monday,April 18, 2022 7:57 PM To: Ben Evans<ben@c!tyscapegoy.com> Cc: brian.cummines@town.southold.nv.us; elizabeth@c!tyscapeeov.com Subject: RE: Dish collocation application at Elijah's Lane, Mattituck (Town of Southold) NYNYCO2191A Thank you! From: Ben Evans<ben@citvscapeeov.com> Sent: Monday,April 18, 2022 12:49 PM To: LG Rightmyer<le@!nranee-Ilc.com> Cc: brian.cummines@town.southold.ny.us: elizabeth@cityscaaeeov.com Subject: RE: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191A Caution:This iis.an.external email and has a suspicious subject or content. Please take care when clicking Links or opening attachments. When in doubt; contact your IT Department Lois, Sorry for not timely getting back to you.Yes,the new information you sent is in order, and we'll be sending our report to the Town today. Regards, Ben Feu gaw4 Senior RF Engineer, Cityscape Consultants i Direct Line: (262) 518-0178 Thiensville, WI 53092 CITYSCAPE CONSULTANTS,INC. 2423 S. Orange Ave#317, Orlando,FL 32806 Toll Free: 877-438-28511 fax: 877-220-4593 www.cityscapegov.com From: Ben Evans [mailto:ben@cityscapegov.coml Sent: Tuesday, April 12, 2022 10:56 AM To: 'LG Rightmyer' Cc: 'brian.cum mings@town.southold.ny.us'; 'elizabeth@cityscapegov.com' Subject: RE: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191A Thank you, Lois. I'll look at these and get back to you later today. Ben Fess Euara Senior RF Engineer, CityScape Consultants Direct Line: (262) 518-0178 Thiensville, WI 53092 CITYSCAPE CONSULTANTS,INC. 2423 S. Orange Ave#317, Orlando,FL 32806 Toll Free: 877-438-28511 fax: 877-220-4593 www.cityscapegov.com From: LG Rightmyer [ma ilto:la inrange-llc.coml Sent: Tuesday, April 12, 2022 10:14 AM To: Ben Evans Cc: brian.cummings2town.southold.ny.us; elizabeth a cityscape ov.com Subject: RE: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191A Attached please find the revised plans and structural analysis. Lois Rightmyer From: Ben Evans<ben@cityscapegov.com> Sent:Tuesday,April 5, 2022 9:25 AM To: LG Rightmyer<lg@inrange-Ilc.com> Cc: brian.cummings@town.southold.nv.us; elizabeth@cityscapegov.com Subject: RE: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191A Caution:This is an external email and has a suspicious subject or content. Please take care when clicking links or opening attachments. When in doubt, contact your IT Department Thanks for the update, Lois. Yes,we would like to have the SA and CDs updated based on the internal cable mounts. 2 Ben Sem Senior RF Engineer, Cityscape Consultants Direct Line: (262) 518-0178 Thiensville, WI 53092 CITYSCAPE CONSULTANTS,INC. 2423 S. Orange Ave#317, Orlando,FL 32806 Toll Free: 877-438-28511 fax: 877-220-4593 www.cityscapegov.com From: LG Rightmyer [mailto:lg@inrange-Ilc.com] Sent:Tuesday, April 05, 2022 7:42 AM To: Ben Evans Cc: brian.cummings0town.southold.ny.us Subject: RE: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191A Good Morning Ben, In regards to your question below regarding the cables, We checked with engineering and confirmed there is a porthole available for dish to Install these cables internally.Will you need a new SA for this and/OR CDs updated? Thank you, Lois On Mar 11, 2022, at 5:49 PM, Ben Evans<ben@citvscapeeov.com>wrote: Lois, Thanks for providing the new structural report. There something else that caught my eye that needs to be addressed.The structure is a monopole and the preference for mounting cables on a monopole is to route them inside, out of sight,which CityScape has in the past seven years stridently recommended to the town regarding this site, although, in spite of our efforts,the structural report indicates that some of the cables are on the outside. Is there a reason or circumstance beyond Dish Wireless' control that would explain why the proposed new cable can't be routed inside the monopole? Fea Senior RF Engineer, CityScape Consultants Direct Line: (262) 518-0178 Thiensville, WI 53092 3 CITYSCAPE CONSULTANTS,INC. 2423 S. Orange Ave#317, Orlando,FL 32806 Toll Free: 877-438-28511 fax: 877-220-4593 1 www.citVscapegov.com From: LG Rightmyer [mailto:lg inrange-Ilc.com] Sent: Friday, March 11, 2022 8:27 AM To: Ben Evans Cc: elizabeth@cityscapeaov.com; brian.cummings(abtown.southold.ny.us Subject: RE: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NYNYCO2191A Attached please find the additional information you Requested. Lois Rightmyer Agent on behalf of Crown Castle/DISH Wireless From: Ben Evans<ben@cityscapeeov.com> Sent: Friday, February 25,2022 4:53 PM To: LG Rightmyer<le@inranee-Ilc.com> Cc:elizabeth(Mcityscapegov.com; brian.cummings@town.southold.nv.us Subject: RE: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NY Thank you, Lois. When may we expect to receive the information in response to our concerns relating to the structural integrity of the tower and platform mount(explained below in my previous email)? 664 smad Senior RF Engineer, Cityscape Consultants Direct Line: (262) 518-0178 Thiensville, WI 53092 CITYSCAPE CONSULTANTS,INC. 2423 S. Orange Ave#317, Orlando,FL 32806 Toll Free: 877-438-28511 fax: 877-220-4593 www.cityscapegov.com From: LG Rightmyer [mailto:lg inrange-Ilc.com] Sent: Wednesday, February 23, 2022 12:20 PM To: Ben Evans Cc: elizabethOcityscapegov.com; brian.cummings@town.southold.ny.us Subject: RE: Dish collocation application at Elijah's Lane, Mattituck (Town of Southold) NY Good Afternoon Ben, Attached please find the EME report requested. Thank you, Lois Rightmyer 4 Agent on Behalf of Crown Castle/DISH Wireless From: Ben Evans<ben@citVscapeeov.com> Sent: Monday, December 20, 20212:36 PM To: LG Rightmyer<le@inrange-Ilc.com> Cc: elizabeth@cityscapeRov.com; brian.cummings@town.southold.nv.us Subject: Dish collocation application at Elijah's Lane, Mattituck(Town of Southold) NY Importance: High Dear Lois Rightmyer, I hope this email finds you well. Cityscape is the third-party reviewer assigned to this application. We find this application incomplete for the following reasons: 1. The Structural Evaluation (letter dated 8/13/2021) compared the proposed tower loading by Dish to the loading specified in a structural analysis report dated 6/9/2021,and on that basis, determined that"the proposed loading change will not have significant impact on the overall tower stress rating." Please provide that earlier 6/9/2021 structural report so that we may verify that conclusion. If the original analysis and the updated evaluation are based on the TIA-222H, standard, please also provide a structural evaluation or analysis for the platform mount. 2. Please provide an RF exposure study as required in §280-70K of the Southold Town Ordinance, demonstrating that the RF emissions of the proposed Dish operation together with the RF emissions from other carriers on the tower,whether existing or proposed, will not cause RF exposure levels to be in excess of the FCC limits in either areas accessible to the general public or areas restricted to workers. The study may be based on actual on-site RF measurements or mathematical models approved by the FCC for such calculations of exposure. Please note that this analysis must be prepared and signed by a qualified professional specializing in radio communication facilities. Please note that the application will be considered incomplete until the above-requested documentation is received and accepted. Thank you for your time, and we thank you in advance for a response. Sincerely, Secy Senior RF Engineer, Cityscape Consultants Direct Line: (262) 518-0178 Thiensville, WI 53092 CITYSCAPE CONSULTANTS,INC. 2423 S. Orange Ave#317, Orlando,FL 32806 Toll Free: 877-438-28511 fax: 877-220-4593 www.citVscapegov.com 5