Loading...
HomeMy WebLinkAbout47958-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE ° SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47958 Date: 6/15/2022 Permission is hereby granted to: Cardona Jr, Charles _.. ........... ...._�................................................._.......................... ........................._....._. ................................. 11610 Main Bayview Rd_ .�._w .... ............ _ .w_.__.wwwwwwwwwwww.._.ww_____.............................www_w.wwwwww_www_w...._._ww Southold._.N.Y........i...19.?..1.........................._............................... ... ......... ........................ To: legalize "as built" HVAC system and construct deck addition to existing single-family dwelling as applied for. Additional approvals will be required. At premises located at: 11610 Main Bayview Rd., Southold ___ ---—_ SCTM # 473889 . Sec/Block/Lot# 88.-5-26 Pursuant to application dated 4/13/2022 and approved by the Building Inspector, To expire on 12/15/2023. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $322.40 CO -ADDITION TO DWELLING $50.00 Total: $772.40 Building Inspector TOWN OF SOUTHOLD-BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 )a1g�� Date Received APPLICATION FOR BUILDING PERMIT I For Office Use Only f. PERMIT NO., � Building lnspector:_.w PR 1 ) 022 Applications and forms must be filled out in their entirety. Incomplete BUl DING DEPT" applications will not be accepted. Where the Applicant is not the owner,an TOWN OF S011.I11HOLD Owner's Authorization form(Page 2)shall be completed. Date: 7. 24 2�- OWNER(S)OF PROPERTY: Name: OVV -._ pr a .� SCTM#1000- -.5— 2— Project Project Address: $i7 ►y //'?;V Phone#: 57,6 6X1 Qd S-3 Email: Mailing Address: /�6/0 ! IeZI SW 7*• Q� A/* ��IF y CONTACT PERSON: 7 ,/ Name: *I CA— X4.9' Mailing Address: 44L Phone#: 6-/6 !Y-7- iia 53 Email: DESIGN PROFESSIONAL INFORMATION: Name: 1 t� Mailirig Address: AJ 'S-r Phone#: 631 Email: CONTRACTOR INFORMAT lN: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑other $ Will the lot be re-graded? ❑Yes ❑No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check II e2 After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with aB applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspector;on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted B r name y(p " : jy/}- ' �J ❑Authorized Agent caner ) Q r Signature of Applicant:" Date: (�, �_ Zp Z 2— STATE OF NEW YORK) S : COUNTYOF Sv� 0,�c ) 404*OL )"12k �,/ -* being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth iri the application file therewith. Sworn before me this 7 day of � .2b a Nbtary Public up I " LEEANN R. MAR INO PROPER�(� OWNER IRIS �� NOTARY PU13LIC-STATE OF NEW .� CO )......... No.01 MA614727 5 (Where the applicant is not'the owner Ouellfled In Suffolk County My CoMmisaion Exptes0t0 I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Air Air Conditioners ' 0 RA16 Series The new degree of comfort:" Rheem Classic® Series ' - 4 Air Conditioners p� RA16 Series Efficiencies 16 SEER/13 EER -� Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kq ISO , 4). i M1=5 tLSTM nmum i "Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star.= Ask your Contractor for details or visit wwmenergystargov." • Composite base pan—dampens sound,captures louver • Diagnostic service window with two-fastener opening— panels,eliminates corrosion and reduces number of fasteners provides access to the high and low pressure. needed • External gauge port access—allows easy connection of • Powder coat paint system—for a long lasting professional finish "low-loss"gauge ports • Scroll compressor—uses 70%fewer moving parts for higher • Single-row condenser coil—makes unit lighter and allows efficiency and increased reliability thorough coil cleaning to maintain"out of the box" • Modern cabinet aesthetics—increased curb appeal with visu- performance ally appealing design • 35%fewer cabinet fasteners and fastener-free base—allow • Curved louver panels—provide ultimate coil protection, for faster access to internal components and hassle-free enhance cabinet strength,and increased cabinet rigidity panel removal • Optimized fan orifice—optimizes airflow and reduces unit • Service trays—hold fasteners or caps during service calls sound • QR code—provides technical information on demand for • Rust resistant screws—confirmed through 1500-hour salt faster service calls spray testing • Fan motor harness with extra long wires allows unit top to be • PlusOneTM Expanded Valve Space—3"4"-5"service valve removed without disconnecting fan wire. space—provides a minimum working area of 27-square inches for easier access • PlusOneTM Triple Service Access—15"wide,industry lead- ing corner service access—makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed,for faster coil cleaning and easier cabinet reassembly INTEGRATED HOME .- FORM NO.All-222 REV.10 Table of Contents Air RAI 6 Series TABLE OF CONTENTS StandardFeature......................................................................................................3 AvailableSKUs ........................................................................................................3 Features&Benefits ..............................................................................................4-5 Model Number Identification....................................................................................6 GeneralData/Electrical Data....................................................................................7 Accessories ............................................................................................................8 WeightedSound Power............................................................................................8 UnitDimensions........................................................................................................9 Clearances...............................................................................................................10 WiringDiagrams ....................................................................................................11 ApplicationGuidelines............................................................................................11 Refrigerant Line Size Information......................................................................12-15 PerformanceData..................................................................................................16 GuideSpecifications ..............................................................................................17 LimitedWarranty....................................................................................................18 INTEGRATED HOME COMFORT Air Standard Feature/Available SKUs 0 RA16 Series Standard Feature Table STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-41 Oa Refrigerant ✓ J ✓ J ✓ ✓ ✓ Maximum SEER 16 16 16 16 16 16 16 Maximum EER 13 13 13 13 13 13 13 Scroll Compressor J J J ✓ J J J Field Installed Filter Drier J J ✓ ✓ J J ✓ Front Seating Service Valves J J ✓ J J J ✓ Internal Pressure Relief Valve J J ✓ J ✓ J ✓ Internal Thermal Overload J J ✓ ✓ J J ✓ Long Line capability ✓ J ✓ ✓ J J J Low Ambient capability with Kit J ✓ J J J ✓ J 3-4-5 Expanded Valve Space J J ✓ ✓ J ✓ ✓ Composite Basepan J J ✓ ✓ ✓ J ✓ 2 Screw Control Box Access J J J ✓ J J ✓ 15"Access to Internal Components J ✓ J J J J J Quick release louver panel design J J ✓ ✓ J J ✓ No fasteners to remove along bottom J ✓ ✓ J J ✓ ✓ Optimized Venturi Airflow J ✓ ✓ J J ✓ J Single raw condenser coil J ✓ If J J J J Powder coated paint J ✓ J J J J J Rust resistant screws ✓ J J J J J J QR code J J J J J ✓ J External gauge ports J J J J J ✓ J Service trays J ✓ J J J J J J=Standard Available SKUs Available Models Description RA1618AJl NA Classic®Series 1 1/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1618AJl NB Classic®Series 1 1/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1624AJ1 NA Classic®Series 2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1624AJl NB Classic®Series 2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1630AJl NA Classic®Series 21/2 tan 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1630AJl NB Classic®Series 21/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636ACl NB Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636AJl NA Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1636AJl NB Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636BC1NB(Canada) Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1642ACl NB Classic®Series 3 1/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1642AJl NA Classic"Series 3 1/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1642AJl NB Classic®Series 31/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1648AClNB Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1648AJl NA Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1648AJl NB Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1660AClNB Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1660AJl NA Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1660AJl NB Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 INTEGRATED HOME COMFORT --on Air Features&Benefits -0 RAI 6 Series Introduction to RA16 Air Conditioner The RA16 is our 16 SEER air conditioner and is part of the Rheem air conditioner product line that extends from 13 to 20 SEER.This highly featured and reliable air conditioner is u ,2 , designed for years of reliable,efficient operation when matched with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. - Our unique composite base(Fl])reduces sound emission,elimi- 13 nates rattles,significantly reduces fasteners,eliminates corro- If in the rare event,greater access is needed to internal compo- sion and has integrated brass compressor attachment inserts nents,such as the compressor,the entire corner of the unit can (Efl). Furthermore it has incorporated into the design,water be removed along with the top cover assembly to have unprece- management features, means for hand placement(❑a )for unit dented access to interior of the unit(9). Extra wire length is maneuvering,screw trays(®)and inserts for lifting off unit incorporated into each outdoor fan and compressor so top pad. cover and control panel can be positioned next to the unit.With minimal effort the plug can be removed from the compressor 0 and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit(9). Outdoor coil heights range from as short as 27"to 48",aiding access to the compressor.Disassembly to this degree and com- plete reassembly only takes a first time service technician less z -- --- than 10 minutes. Service Valves©)are rigidly mounted in the composite base with 3" between suction and discharge valves,4"clearance below service valves and a minimum of 5"above the service valves,creating industry leading installation ease.The minimum 27 square-inches around the service valves allows ample room to remove service valve Schrader prior to brazing,plenty of clear- -- ance for easy brazing of the suction and discharge lines to ser- vice valve outlets,easy access and hookup of low loss refriger- All units utilize strong formed louver panels which provide indus- ant gauges(0),and access to the service valve caps for try leading coil protection. Louver removal for coil cleaning is opening.For applications with long-line lengths up to 250 feet accomplished by removing one screw and lifting the panel out of total equivalent length,up to 200 feet condenser above evapora- the composite base pan.(n)All RA16 units utilize single row tor,or up to 80 feet evaporator above condenser,the long-line coils(,$)making cleaning easy and complete,restoring the instructions in the installation manual should be followed. performance of the air conditioner back to out of the box perfor- mance levels year after year. L-8� a ■ io . s s Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover,revealing the The outdoor fan motor has sleeve bearings and is inherently industry's largest 15"wide and 14"tall control area(E).With all protected.The motor is totally enclosed for maximum protection this room in the control area the high voltage electrical whip(0) from weather,dust and corrosion.Access to the outdoor fan is can easily be inserted through the right size opening in the bot- made by removing four fasteners from the fan grille.The outdoor tom of the control area.Routing it leads directly to contractor fan can be removed from the fan grille by removing 4 fasteners lugs for connection.The'low voltage control wires(ia)are easily in the rare case outdoor fan motor fails. connected to units low voltage wiring. If contactor or capacitor („)needs to be replaced there is more than adequate space to Each cabinet has optimized composite fan orifice assuring make the repair.Furthermore,if high pressure and low pressure efficient and quiet airflow. model was not purchased but is desired to be installed in the field,the service window(,z)can be removed by removing two screws,to access the high and low side Schrader fittings for easy ,s field installation.The entire corner can be removed providing ultimate access to install the high and low pressure switch.4 INTEGRATED HOME COMFORT Air Features&Benefits 'a RA16 Series The entire cabinet has powder post paint(20)achieving 1000 Optional Accessories hour salt spray rating,allowing the cabinet to retain its aesthetics (Refer to accessory chart for model#) throughout its life. Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation Compressor Sound Cover •Reinforced vinyl compressor cover containing a 1'/2 inch thick batt of fiberglass insulation ip •Open edges are sealed with a one-inch wide hook and loop fastening tape Compressor Hard Start Kit Scroll compressors with standard internal pressure relief and •Single-phase units are equipped with a PSC compressor internal thermal overload are used on all capacities assuring motor,this type of motor normally does not need a potential longevity of high efficient and quiet operation for the life of the relay and start capacitor product. • Kit may be required to increase the compressor starting Each unit is shipped with filter drier for field installation and will torque,in conditions such as low voltage trap any moisture or dirt that could contaminate the refrigerant Low Ambient Kit system.. •Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls •This Kit can be added in the field enabling unit to operate properly down to 0°in the cooling mode •Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit 3"/6"/12" All cabinets have industry leading structural strength due to the •Gray high density polyethylene feet are available to raise unit composite base pan(E]),interlocking corner post(®),formed off of mounting surface away from moisture curved louver panels(2a)and drawn top cover(®)making it Low Pressure the most durable cabinet on the market today. •Can be added in field enabling the unit to shut off compressor Each RA16 capacity has undergone rigorous psychometric test- on loss of charge ing to assure performance ratings of capacity,SEER NOTE:Unit can be purchased with high and low pressure and EER per AHRI Standard 210/240 rating condi- aUL ,s installed at factory.(Refer to SKU list) tions.Also each unit bears the UL mark and each unit Lmm is certified to UL 1995 safety standards. High Pressure •Can be added in field enabling unit to shut off compressor if Each unit has undergone specific strain and modal testing to unit loses outdoor fan operation. assure tubing(25)is outside the units natural frequency and that the suction and discharge lines connected to the compressor NOTE:Unit can be purchased with high and low pressure withstand any starting,steady state operation or shut down installed at factory.(Refer to SKU list) forces imposed by the compressor. Decorative Top All units have been sound tested in sound chamber to AHRI 270 •Can be installed on fan grille rating conditions,and A-weighted Sound Power Level tables produced,assuring units have acceptable noise qualities(see page 9). Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the RA16 range from as low as 70.7 dBA to 76.6 dBA. All units have been ship tested to assure units meet stringent "over the road"shipping conditions. As manufactured all units in the RA16 family have cooling capa- bility to 55°F.Addition of low ambient control will allow the unit to operate down to WE Factory testing is performed on each unit.All component parts meet well defined specification and continually go through receiving inspections.Each component installed on a unit is scanned,assuring correct component uti- lization for a given unit capacity and voltage.All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled,each units'complete refrigerant system is helium leak tested.All units are fully charged from the factory for up to 15 feet of piping.All units are factory run tested. The RA16 has a 10-year conditional compressor and parts war- ranty(registration required). INTEGRATED HOME COMFORT 5 Air Conditioners* JLb R A 16 24 A J 1 N A D Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option y 3 Category BTU/HR Code Rheem A-Air Conditioners 16-16 SEER 18-18,000 [5.28 kW] A-1st Design J-1 ph,208-230/60 1 -Single-stage N -Non-Communicating A- 1st Design N/A rD 3 24-24,000 [7.03 kW] B -2nd Design C-3ph,208-230/60 B-2nd DesignCR cr 30-30,000 [8.79 kW] EZ CD 36-36,000 [10.55 kW] 42-42,000 [12.31 kW] 3 48-48,000 [14.07 kW] 60-60,000 [17.58 kW] *See page 3 for available SKUs. [ ]Designates Metric Conversions Air General Data/Electrical Data RA16 Series Physical Data PHYSICAL DATA Model No. RA1618 RA1624 RA1630 RA 636 RA1636 RA1642 RA1648 RA1660 Nominal Tonnage 1.5 2.0 2.5 3.0 3.0 3.5 4.0 5.0' Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oz.' 82 87 113 108 108-- 150 174 201 Compressor Type Scroll - Outdoor Coil Net face area-Outer Coil 12.1 14.8 16.2 18.8 17.29 24.2 28.3 32.3 Net face area-Inner Coil - - - - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 1 Fins per inch 22 22 22 22 22 22 22 22 Outdoor Fan Diameter-in. 20 24 26 26 24 26 26 26 Number of blades 3 2 3 3 3 3 3 3 Motor hp 1/8 1/6 1/5 1/3 1/6 1/3 1/3 1/3 CFM 2405 2850 3915 4340 3300 4450 4660 4775 RPM 1095 851 710 819 - 825 829 828 795 watts 155 147 102 131 1 167 193 198 239 Shipping weight-lbs. 147 149 159 177 199 212 232 247 Operating weight-lbs. 140 142 152 170 192 205 225 240 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)2 20 20 30 35 1 35 40 40 50 Minimum circuit ampacity3 12 14 18 23 1 23 25 1 25 34 Compressor Rated load amps 1 9 10.3 12.8 15.4 1 15.4 16.7 17 23.7 Locked rotor amps 47.5 61.6 67.3 83.9 83.9 109 123.9 152.5 Condenser Fan Motor Full load amps 0.7 0.6 2.8 3.5 1.5 3.5 3.5 3.5 Locked rotor amps 1.3 1.5 2.3 - .8 - 2.3 - Line Voltage Data(Volts-Phase-Hz) - - - 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection(amps)2 - - - 25 20 25 30 35 Minimum circuit ampacity3 - - - 17 14 18 21 24 Compressor Rated load amps - - - 10.4 10.4 1 11.2 1 13.6 15.9 Locked rotor amps - - - 73 73 88 83.1 110 Condenser Fan Motor Full load amps - - - 3.5 .8 3.5 3.5 3.5 Locked rotor amps - - - - 1.5 - 2.3 - �Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. __0 INTEGRATED HOME COMFORT Air Accessories/Weighted Sound Power 0 RA16 Series Accessories Model No. RA1618 RA1624 RA1630 RA1636 RA1642 RA1648 RA1660 Compressor crankcase heater* 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 r Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC' 200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61=AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 614MG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AM6120/240V 61-AMG120/240V 61-AMG120/240V Classic Top Cap w/Label 1 91-101123-21 1 91-101123-21 91-101123-21 1 91-101123-21 1 91-101123-21 1 91-101123-21 1 91-101123-21 *Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dBA) Unit Size Voltage,Series Standard TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) Rating(dBA) 125 250 500 1000 2000 4000 8000 RA1618 76.6 53.4 60 65.7 66.3 64.2 58.8 52.6 RA1624 75.5 49.9 58.4 61.4 64.1 61.6 57.3 50.8 RA1630 74.3 48.4 57.4 62.6 64.5 61.5 56.5 51.5 RA1636 76.4 54.5 62.7 1 67.1 66.5 62.7 58.5 54.3 RA1636 75 56.1 58.7 63.1 66.1 62.3 59 55.7 RA1642 70.7 47.5 51 60.2 60.7 59.7 53.6 50.4 RA1648 74.3 51.2 56.1 64.5 65.6 60.7 56.6 52.6 RA1660 74.6 50.1 55.1 65.6 64.8 63.2 57.4 56.4 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) INTEGRATED HOME COMFORT Air Unit Dimensions a RA16 Series Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height), L(Length) W(Width) NO. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA1618 27 685 29.75 755 29.75 755 27.375 695 32.25 819 32.25 819 RAI 624 27 685 33.75 857 33.75 857 27.375 695 36.25 921 36.25 921 RA1630 27 685 35.75 908 35.75 908 27.375 695 38.25 972 38.25 972 RA1636 31 787 35.75 908 35.75 908 31.375 797 38.25 972 38.25 972 RAI 636 31 787 33.75 857 33.75 857 31.375 797 36.25 921 36.25 921 RAI 642 39 990 35.75 908 35.75 908 39.375 1000 38.25 972 38.25 972 RAI 648 45 1143 35.75 908 35.75 908 45.375 1153 38.25 972 38.25 972 RA1660 51 1295 35.75 908 35.75 908 51.375 1305 38.25 972 38.25 972 ALLOW 60"[1524 mm] OF CLEARANCE A i R W D 1 S C A L A R G E H SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12'1305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-02-00 COMFORTINTEGRATED HOME CLEARANCES JL6 D WALL, V1/ALL D " i w 611 ) 7 (152.4 24" ; CD (609.6) y N Service 24" 12" 12" (609.6) (304.8) 17, y. Service (304.8) r- 6" (152.4)LI 6" (152.4) 12" (304.8) rn WALL 24" 2.411 24„ (609.6) (609.6) (609.6 Service Service Service 18/1 24" 24„ (457.2) (609.6) (609.6) 24" recommended 24" recommended 6" minimum 6" minimum NOTE: NUMBERS IN () = mm IMPORTANT.,When installing multiple units in an alcove,roof well or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. ST-A1225-01-00 "Oj Air Wiring Diagram/Application Guidelines 0 RA16 Series Control Wiring FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(W/BK)AND W2(W/BL)BEJUMPERED TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE 90 Y G R BR-BROWN WIRE YL-YELLOW WIRE BR-BROWN WIRE X-WIRE CONNECTION R-RED WIRE YL-YELLOW WIRE W/BK-WHITE WIRE WITH BLACK STRIPE GBK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED), X-WIRE CONNECTION TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX * WBL TYPICAL CONDENSING FI TYPICAL CONDENSING R UNIT WBK UNIT G/BK YL Y YL X YL BR BR BR C PU Application Guidelines 1.Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01 -in.wc. 2.Minimum outdoor operation air temperature for cooling mode Without low-ambient operation accessory is 55°F(12.8°C). 3.Maximum outdoor operating air temperature is 125T(51.7°C). 4.For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory—supplied filter drier must be installed. INTEGRATEO HOME COMFORT Refrigerant Line Size Information JLb 13-16 SEER Single-Stage Air-Conditioners y Apply Long Line Guidelines if Equivalent Length(Feet) Allowable Allowable Linear Line Length Exceeds n m Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 1 51-75 1 76-100 1 101-125 1 126-150 1 151-175 1 176-200 1 201-225 226-250 0 Size Size 7(A/BIC 4 (-)A14 m m (-)A13 w/X (-)A16 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier m 5/16" 5/8" n/a n/a n/a n/a 25/0.99 50/0.97 86 10.94 tl. 4910.92.,' 32 tO.90, 'NR NR NR NR, ' NR v� 3/8" 5/8" 108 85 90 82 25/0.99 50/0.97 75/0.04, 95/0.92 v89/0.90 NR NR NR NR NR "' m 5/16" 3/4" n/a 128 135 123 25/1.00 50/0.99 66/0.98 49/0.98 32/0.97 15/0.196 t NR. ',WR NR NR o 3/8° 3/4" 108 85 90 82 25/1.00 50/0'.99 75/0.98 95/0.98 89/0.97 84/0.96 7810.95, 72`/0.94 67/0.95 6110.93 m 3 Ton 1/2' 3/4" 54 43 45 41 25/1.00 50/0.99 75/0.98 100/0.98 100/0.97 100/0.916 10010.95 100/0.94 100/0.93 100/0.93 D 5116" 7/8" n/a 128 135 123 25/1.00 50/1.00 66/1.00 49/0.99 32/0.99 15/0.99 NR NR IN NR 3/8" 7/8" 108 85 90 82 25/1.00 1 50/1.00 1 75/1.00 95/0.99 89/0.99 1 84/0.99 78/0.98 72/0.98 67/0.98 61 10.97 1/2" 7/8" 54 43 45 41 25/1.00 50/1.00 75/1.00 100/0-99 100/0-99 100/0.99 100/0.98 100/0.98 100/0.98 100/0.97 01 NOTES: 1. Do not exceed 200 ft linear line length. 2. *Do not exceed 180 ft vertical separation if outdoor unit is above indoor unit. 3.**3/4"suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4. Always use the smallest liquid line allowable to minimize refrigerant charge. 5 A licatTansAflade8`inYrhtgrayiri�ic`atecapbciCymuittplieisbe etw en0:90and'0?36Wfii61iarenotteeommei ed tutareaiiaw'ed 1 6. pp(ii(bons ha rt ackgr�:are ng ee>ommanda "to:azeesstva gni arsu 4 re.ire Oro Refrigerant Line Size Information (con't.) 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Guidelines if Equivalent Length(Feet) Allowable Allowable Linear Line Length Exceeds Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 1 51-75 1 76-100 101-125 126-150 1 151-175 1 176-200 201-225 226-250 Size Size 7(A/BIC 4 (-)A14 (-)Al WIX (-)Al Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier 3/8" 3/4" 148 110 N/A 35 25/0.99 50/0.98 7510,96 ° 77/0.95. 61/0,93- 5710.92'- 4610.91. 1/2" 3/4" 74 55 N/A 18 25/0.99 50/0.98 75/0'96.. 100[01'95-< 100'10,93 '-`-100/,-6.92 10010,91 4 Ton 3/8" 7/8" 148 110 N/A 35 25/1.00 50/0.99 75/0.99 77/0.98 67/0.97 57/0.97 4610.96 .36/O.96. 2610,95 " 1516.95 1/2" 7/8" 74 55 N/A 18 25/1.00 50/0.99 75/0.99 100/0.98 100/0.97 100/0.97 100/0.96 100/0.96 9910.95 9710.95' ` 3/8" 3/4" 78 0 N/A 0 25/0.99 50/0.97 75/.0,94 6110.92' . 4610,90 1/2" 3/4" 39 0 N/A 0 25/0.99 50/0.97 750,94 100/9.92 10010.90, 3/8" 7/8" 78 0 N/A 0 25/1.00 50/0.99 75/0.98 61/0.97 4610.96 '32/0.95 1810:94 5 Ton 1/2" 7/8" 39 0 N/A 0 25/1.00 50/0.99 75/0.98 100/0.97 100"/0.96 1001./0.95 97/0.94 95!0,94 92/0.93- 8910.92 . 3/8" 1-1/8" 78 0 N/A 0 25/1.01 50/ 1.01 75/1.00 61/1.00 46/0.99 32/ 0.99 18/0.99 1/2" 1-1/8" 39 0 N/A 0 25/1.01 50/1.01 75/1.00 100/1.00 100/0.99 100/0.99 97/0.99 95/0.99 92/ 0.99 89/0.98 NOTES: 1. Do not exceed 200 ft linear line length. 2. *Do not exceed 180 ft vertical separation if outdoor unit is above indoor unit. 3.**3/4"suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4. Always use the smallest liquid line allowable to minimize refrigerant charge. 5 lica86ns saded'n Iig6t§cayiridtcate capacl[ym. utd�1u8rsbetween 0;90an0:96"wtft a"re noceomrbutaealow: rfed] s. pc `ssfade�TndaTgray are no amconamea toexcessive 1gui'id or sucOog pressure drop 7 • This application is acceptable because the 50'vertical rise is less than the maximurnsise of 100' Example:A(-)Al436AJINA is installed 50'below the indoor unit,requires 75'of 1/2"diameter for this application.The application is also considered to have a long line set since 75 linear feet liquid line,3/4"diameter suction line,and 4 90°LR elbows,and a filter drier. exceeds the limit of 43 feet.Reference the long line set section of the I&0 for detail. •Fitting Equivalent Length(ft.)=(4 x.9)+6=9.6' • •Total Equivalent Length(ft.)=75'+9.6'=84.6' 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Guidelines if Equivalent Length(Feet) Allowable Allowable Linear Line Length Exceeds Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 51-75 76 100 101-125 1 126-150 1 151-175 176-200 201-225 226-250 Size Size (-)A13 (-)Al4 (-)Al4 (_)Al6 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier A/B/C W/X ��� 5/16" 5/8" n/a n/a n/a n/a 25/0.99 50/0.97 S6/0,94' . 49/0.92 32 L,0,90 NR NR " NO NO NO. 3/8" 5/8" 108 85 90 82 25/0.99 50/0.97 75/0.94 95/0,92 8910,90 NR NR 'NO NR . NR., D 5/16" 3/4" n/a 128 135 123 25/1.00 50/0.99 66/0.98 49/0.98 32/0.97 157 0.96N(t NR° NR NR 3/8" 3/4" 108 85 90 82 25/1.00 50/0.99 7510.98 95/0.98 89/0.97 �84/0,96 '18/9,95 72/0.94 67/,0.93 61/0:93, a 3 Ton - 1/2" 3/4" 54 43 45 41 25/1.00 50/0.99 75/0.98 100/0.9 100/0.97 100/0:96'. 10070.95 100/0.94 .100j0.93 100/093 '- y � m 5/16" 7/8" n/a 128 135 123 25/1.00 50/1.00 66/1.00 49/0.99 32/0.99 15/0.99 NO NO NR NFC ai r 3/8" 7/8" 108 85 90 82 25/1.00 50/1.00 75/1.00 95/0.99 89/0.99 84/0.99 78/0.98 72/0.98 67/0.98 61/0.97 m 1/2" 7/8" 54 43 45 41 25/1.00 50/1.00 75!1.00 100/0.99 100/0.99 100/0.99 100/0.98 100/0.98 100/0.98 100/0.97 CN N N O 3 w 0 D Refrigerant Line Size Information JL6 13-16 SEER Single-Stage Air-Conditioners n Apply Long Line Guidelines it Equivalent Length(Meters) Allowable Allowable Linear Line Length Exceeds y Liquid Line Suction Line Those Shown Below Meters <8 8-15 16-23 24-30 31-38 39-46 47-53 54-61 62-69 70-76 Unit Size (Meters) Size Size � w mm[in.] mm[in.] (-)A13 (-)A14 ()A14 ()A16 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)'/Capacity Multiplier AB/C W/XCD w r CD 6.35[1/4] 15.88[5/8] N/A N/A N/A N/A 8/1.00 15/0.99 19/0.98 13/0.98 7/0.97 2/0.97 N/R N R N/RNIR 5.3 KW 7.84[5/16] 15.88[5/8] N/A 68 60 57 8/1.00 15/0.99 23/0.98 30/0.98 28/0.97 27/0.97 25/0.96 24/0.96 22/0.95 21/0.94 m 11.5 Ton] 9.53[3/8] 15.88[5/8] 54 45 40 38 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 30/0.97 30/0.96 30/0.96 30/0.95' -3016.94 0 **SEE 6.35[1/4] 19.05[3/41** N/A N/A N/A N/A 8/1.00 15/1.00 19/0.99 13/0.99 7/0.99 2/0.99 NIR N/R N/R- N/R w NOTE 3 7.94[5/16] 19.05[3/41** N/A 68 60 57 811.00 15/1.00 23/0.99 30/0.99 28/0.99 27/0.99 25/0.99 24/0.98 22/0.98 21/0.98 9.53[3/8] 19.05[3/4]** 54 45 40 38 811.00 15/1.00 2310.99 30/0.99 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 6.35[1/4] 15.88[5/8] N/A N/A N/A N/A 8/0.99 15/0.98 6/0.97 N/R N/R NIR NIR N/R N/R NIR 7.94[5/16] 15.88[5/8] 65 59 53 53 8/0.99 15/0.98 23/0.97 27/0.96 23/0.95 21 10.94 19/0.93 16/0,92 14/0.91 11/0.90 7.0 KW 9.53[3/8] 15.88[5/8] 43 39 36 36 8/0.99 15/0.98 23/0.97 30/0.96 30/0.95 ` 30/0.94 30/0.93 29/0.92 2810.91 27/0.90 [2 Ton] 6.35[1/4] 19.05[3/4] N/A N/A N/A N/A 8/1.00 15/1.00 6/0.99 NIR NIR N/R N/R N/R N/R N/R 7.94[5/16] 19.05[3/4] 65 59 53 53 8/1.00 15/1.00 23/0.99 27/0.99 23/0.98 21/0.98 19/0.98 16/0.97 14/0.97 11/0.96 9.53[3/8] 19.05[3/4] 43 39 36 36 8/1.00 15/1.00 23/0.99 30/0.99 30/0.98 30/0.98 30/0.98 29/0.97 28/0.97 27/0.96 7.94[5/16] 15.88[5/8] N/A N/A 34 34 8/0.99 15/0.98 23/0.96 2110.94 18/0.93 1510.91 11/0.90 WR N/R NIR, 8.8 KW 9.53[3/8] 15.88[5/8] 43 36 22 22 8/0.99 15/0.98 2310.96 30/0:94 30/0.93 29/0.91 27/0.90 N/R NIR' NIR [2.5 Ton] 7,94[5/16] 19.05[3/4] 65 53 34 34 8/1.00 15/0.99 23/0.99 21/0.98 18/0.98 15/0.97 11/0.96 8/0.96 4/0.95 N/R 9.53[3/8] 19.05[3/4] 43 36 22 22 8/1.00 15/0.99 23/0.99 30/0.98 30/0.98 29/0.97 27/0,96 26/0,96 25/0.95 24/0.95 ® 7.94[5/16] 15.88[5/8] N/A N/A N/A N/A 8/0.99 15/0.97 20/0.94 15/0.92 10/0.90 NIR N/R NIR NIR' N/R: 9.53[3/8] 15.88[5/8] 33 26 27 25 8/0.99 15/0.97 23/0.94 29/0.92 27/0.90 NIR, N/R N/R NIR N/R ® 7.94[5/16] 19.05[3/4] N/A 39 41 37 8/1.00 15/0.99 20/0.98 15/0.98 10/0.97 5/0.96 NIR NIR N/R N/R ® 10.6 KW 9.5313/81 19.05[3/4] 33 26 27 25 8/1.00 15/0.99 23/0.98 29/0.98 27/0.97 26/0.96 24/0.95 22/0.94 2010.93 19/0.93 [3 Ton] 12,7[1/2] 19.05[3/4] 17 13 14 12 8/1.00 15/0.99 23/0.98 30/0.98 30/0.97 30/0.96 30/0.95 301.0.94 30/0.93 30/0.93 7.94[5/16] 22.23[7/8] N/A 39 41 37 8/1.00 15/1.00 20/1.00 15/0.99 10/0.99 5/0.99 N/R N/Ft NIB NIR 9.53[3/8] 22.23[7/8] 33 26 27 25 8/1.00 15/1.00 23/1.00 29/0.99 27/0.99 26/0.99 24/0.98 22/0.98 20/0.98 19/0.97 1/2[12.7] 22,23[7/8] 17 13 14 12 8/1.00 15/1.00 23/1.00 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 30/0.97 9.53[3/8] 19.05[3/4] 46 31 23 23 8/0.99 15/0.98 23/0.97 2710.96 24/0.95 22/0.94 20/0.92 17/0.91 15/0.90 NIR 12.3 KW 12.7[1/2] 19.05[3/4] 23 15 11 11 8/0.99 15/0.98 23/0.97 36/0,96' 30/0.95 3010.94 3010.92 30/0.91 30/0.90 ',NIR [3.5 Ton] 9.53[3/8] 22.23[7/8] 46 31 23 23 8/1,00 15/1.00 23/0.99 27/0.99 24/0.99 22/0.98 20/0.97 17/0.97 1510.96 13'/0.96 12.7[1/2] 22.23[7/8] 23 15 11 11 8/1.00 15/1.00 1 23/0.99 F-30/0,99 30/0.99 30/0.98 30/0.97 30/0.97 30/0.96 30/0,96 NOTES: 1. Do not exceed 61 meters linear line length. 2. *Do not exceed 55 meters vertical separation if outdoor unit is above indoor unit. 3.**19.05 mm[3/4 in.]vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4. Always use the smallest liquid line allowable to minimize refrigerant charge. 5. „ioicatFons sshadedTn lig`h#gay iniiioti3capacit mt71#iplie�s befween 0:90 do `0:96 wliicli are no] a coinfiende "tit#ar aI owed, 6. 'flcafiBnssha ed din Tark ra are ni t ecommended duelxc ive"IC ui6 ak suc ion tessure dro .: Refrigerant Line Size Information (con't.) 13-16 SEER Single-Stage Air-Conditioners Allowable Allowable Apply Long Line Guidelines if Equivalent Length(Meters) Linear Line Length Exceeds Liquid Line Suction Line Those Shown Below Meters <8 8-15 16-23 24-30 31-38 39-46 47-53 54.61 62-69 70-76 Unit Size Size Size (Meters) mm[in.] mm[in.] (-)At3 (-)A14 (-)A14 ()A16 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier A/B/C W/X 9.53[3/8] 19.05[3/4] 45 34 N/A 11 8/0.99 15/0:98 2310.96 2410:95° 207 0.93 a` 177 0.92 14 if0.91`•' N/R` NIRWR 14.1 KW 12.7[1/2] 19.05[3/4] 23 17 N/A 5 8/0.99 15/0.98 23 40,96 30!0'.95'•- ° 3010.93 • 30 10.'92;;, 30 i 0.91 N/R NIR NIR [4 Ton] 9.53[3/8] 22.23[7/8] 45 34 N/A 11 8/1.00 15/0.99 23/0.99 24/0.98 20/0.97 17/0.97 1410.96 ''11 10:96 8/0.95 12.7[1/2] 22.23[7/8] 23 17 N/A 5 8/1.00 15/0.99 23/0.99 30/0.98 30/0.97 30/0.97 30'10:96 30%6.96 300.195-, 30`h0.95' 9.53[3/8] 19.05[3/4] 24 0 N/A 0 8/0.99 15/0.97 2310.94- 1 gj 0192 -14/0.90; N/R NIR N/R NIR NIR 12.7[1/2] 19.05[3/4] 12 0 N/A 0 8/0.99 15/0.97 2370194 30/0:92 30t 0.90 N/R N!R N/R N/R N/R 17.6 KW 9.53[3/8] 22.23[7/8] 24 0 N/A 0 8/1.00 15/0.99 23/0.98 19/0.97 14L6,96' 10/0.95,, 5/,0.94 NIR N/A N/R [5 Ton] 12.7[1/2] 22.23[7/8] 12 0 N/A 0 8/1.00 15/0.99 23/0.98 30/0.97 3010.96 30/0:95'- 30/0.94, 29/0.94 2810.93: 2Z/0.62 9.53[3/8] 28.58[1-1/8] 24 0 N/A 0 8/1.01 15/1.01 23/1.00 1971.00 14/0.99 10/0.99 5/0.99 N/H NIR NIR 12.7[1/2] 28.58[1-1/8] 12 0 N/A 0 8/1.01 15/1.01 23/1.00 30/1.00 30/0.99 30/0.99 30/0.99 29/0.99 28/ 0.99 27/0.98 NOTES: 1. Do not exceed 61 meters linear line length. 2. "Do not exceed 55 meters vertical separation if outdoor unit is above indoor unit. 3.""19.05 mm 13/4 in.]vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4. Always use the smallest liquid line allowable to minimize refrigerant charge. 5. [� - Flons.shad d' "0'g-h�gray indicate aapaci ml�itT i{eis bStween 0:90 and 0:96 t high ora,of ecommentled B e;alfowed; s. �Applica oL s irade`d in" ba a,aze no�acammonde�lr due excess vel(u1d orgn ressore ro JL6 • D M M D rn m m m w. r m CN N 7 O ' 3 w 0 Air Performance Data �i RAI 6 Series Performance Data @ AHRI Standard Conditions-Cooling Designated Tested Combination(DTC) Total Capacity Net Sensible Net Latent Outdoor Unit Indoor Coil BTU/H[kW1 BTU/H[kW] BTU/H[kW] SEER EER Indoor CFM[L/sl RA1618AJ1 RCF2417STA 18000 [5.3] 13500 [4.01 4500[1.3] 14.50 12.20 600[283.2] RA1624AJ1 RCF2417STA 24000 [7.0] 17500 [5.1] 6500[1.9] 14.50. 12.20 800[377.6] RA1630AJ1 RCF3617STA 28400 [8.3] 21600 [6.3] 6800[2.0] 14.50 12.20 1025[483.71 RA1636AJ1 RCF3617STA 34800[102] 24700 [7.2] 10100[3.0] 14.50 12.20 1000[471.9] RA1636BJ1 RCF3617STA 35800[10.5] 25500 [7.5] 10300[3.0] 14.50 12.20 1100[519.11 RA1642AJ1 RCF4821STA 41000[12.0] 30400 [8.9] 10600[3.1] 14.50 12.20 1425[672.5] RA1648AJ1 RCF4821MTA 46000[13.5] 33200 [9.7] 12800[3.8] 15.10 12.50 1600[755.1] RA1660AJ1 RCF6024STA 56500[16.6] 41200[12.1] 15300[4.5] 15.10 12.50 1525[719.7] Air Handler Outdoor Total Capacity Net Sensible Net Latent Indoor CFM Unit Air Handler BTU/H[kW1 BTU/H[kW] BTU/H[kW] SEER EER [L/sl RA1618AJ1 RMT2417STAN 18000 [5.3] 13500 [4.0] 4500[1.3] 16.00 13.00 600[283.2] RA1624AJ1 RMT2417STAN 24000 [7.0] 17500 [5.1] 6500[1.9] 16.00 13.00 800[377.6] 'RA1630AJ1 RMT3617STAN 29000 [8.5] 21600 [6.3] 6800[2.0] 16.00 13.00 1000[471.9] RA1636AJ1 RMT36211VITAN 35400[10.3] 24700 [7.2] 10100[3.0] 16.00 13.00 1000[471.9] RA1642AJ1 RMT4821STAN 41500[12.2] 33200 [9.7] 12800[3.8] 16.00 13.00 1400[660.7] RA1648AJ1 RMT4821STAN 42000[12.2] 41200[12.1] 15300[4.5] 16.00 13.00 1400[660.7] RA1660AJ1 RHIT6021STAN 56000[16.4] 41200[12.1] 15300[4.5] 15.50 12.50 1575[755.2] NOTE:This data includes DTC(Designated Test Combination)ratings and is for reference purposes only.A full listing of official ratings and system match-ups,along with downloadable certificates,can be accessed from the AHRI website:www.ahridirectory.org. [ ]Designates Metric Conversions Air Guide Specifications 0 RA16 Series GUIDE SPECIFICATIONS General AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER System Description RA16 Outdoor-mounted, air-cooled, split-system air conditioner com- 1-1/2 TO 5 NOMINAL TONS posite base pan unit suitable for ground or rooftop installation. Fans Unit consists of a hermetic compressor, an air-cooled coil, pro- — Condenser fan will be direct-drive,propeller type, discharging peller-type condenser fan, suction and legend line service valve, air upward. and a control box.Unit will discharge supply air upward as shown — Condenser fan motors will be totally enclosed, 1-phase type on contract drawings. Unit will be used in a refrigeration circuit to with class B insulation and permanently lubricated bearings. match up to a coil unit. Shafts will be corrosion resistant. Quality Assurance Fan blades will be statically and dynamically balanced. — Unit will be rated in accordance with the latest edition of AHRI _ Condenser fan openings will be equipped with coated steel Standard 210. wire safety guards. — Unit will be certified for capacity and efficiency, and listed in Compressor the latest AHRI directory. — Compressor will be hermetically sealed. —'Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Compressor will be mounted on rubber vibration isolators. — Unit will be constructed in accordance with UL standards and Condenser Coil will carry the UL label of approval. Unit will have c-UL-us — Condenser coil will be air cooled. approval. Coil will be constructed of aluminum fins mechanically bonded — Unit cabinet will be capable of withstanding ASTM 13117 1000- to copper tubes. hr salt spray test. Refrigeration Components —Air-cooled condenser coils will be leak tested at 150 psig and — Refrigeration circuit components will include liquid-line shutoff pressure tested at 550 psig. valve with sweat connections, vapor-line shutoff valve with — Unit constructed in IS09001 approved facility. sweat connections, system charge of R-41 OA refrigerant, and Delivery,Storage,and Handling compressor oil. — Unit will be shipped as single package only and is stored and — Unit will be equipped with filter drier for R-41 OA refrigerant for handled per unit manufacturer's recommendations. field installation. Warranty for inclusion b specifying en sneer U.S.and Operating Characteristics y g —The capacity of the unit will meet or exceed Btuh at a Canada only. p Y suction temperature of °F/°C. The power consumption Products at full load will not exceed kW. Equipment — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at Factory assembled, single piece, air-cooled air conditioner unit. conditions of CFM entering air temperature at the evap- Contained within the unit enclosure is all factory wiring, piping, orator at °F/°C wet bulb and °F/°C dry bulb, and controls,compressor,refrigerant charge R-41 OA,and special fea- air entering the unit at °F/°C. tures required prior to field start-up. —The system will have a SEER of Btuh/waft or greater at Unit Cabinet DOE conditions. — Unit cabinet will be constructed of galvanized steel, bonder- Electrical Requirements ized,and coated with a powder coat paint. — Nominal unit electrical characteristics will be v, single —All units constructed with louver coil protection and corner post. phase,60 hz.The unit will be capable of satisfactory operation Louver can be removed by removing one fastener per louver within voltage limits of v to V. panel. — Nominal unit electrical characteristics will be v, three phase,60 hz.The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features. = Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. COMFORTINTEGRATED HOME Air Limited Warranty �i RAf6 Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required)...............................Ten(10)Years period stated,in accordance with the terms of the limited warranty. Tor complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 18 INTEGRATED OCOMFORT y .. Air Notes �i RA16 Series -Do INTEGRATED • •• 1 .. The new degree of comfort:" In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating 5600 Old Greenwood Road Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72908 www.rheem.com Brampton,Ontario • L6Y OP5 INTEGRATED HOME COMFORT PRINTED IN U.S.A.5/21 QG FORM NO.A11-222 REV.10 r Y �e Gas Furnaces l l 0 Air R95T Series / 1 1 The new degree of comfort:" . Rheem Classic® Series Multi-position Gas Furnaces R95T Series 95%A.F.U.E.t Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW] I tA.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with '�.#* •;�. Department of Energy test procedures. f • 95% residential gas furnace CSA certified • Blower Shelf design—serviceable in all furnace orientations • 4 way multi-poise design • Pre marked hoses—insures proper system drainage • PlusOnel"Diagnostics 7-Segment LED all units • Vent with 2" or 3" PVC • PlusOneTM Ignition System—DSI for reliability and longevity • Replaceable Collector box • PlusOneT11 Water Management System with patented Blocked • Hemmed edges on cabinet and doors Drain Sensor • Constant Torque electrically commutated motor • Heat exchanger is removable for improved serviceability. a Quarter turn fasteners for tool less access Aluminized steel primary and stainless steel secondary con- struction provide maximum corrosion resistance and thermal system set up fatigue reliability. • Low profile"34 inch"cabinet,ideal for space constrained • Self priming condensate trap installations. • Solid bottom included • Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE standard 193 INTEGRATED HOME COMFORT FORM NO.G11-538 REV.14 i Air Table of Contents �i R95T Series TABLE OF CONTENTS Standard&Optional Equipment ......................................................................3 Physical Data&Specifications ........................................................................4 Model Number Identification............................................................................5 DimensionalData............................................................................................6 Blower Performance Data................................................................................7 Accessories....................................................................................................8 LimitedWarranty............................................................................................9 INTEGRATED s • •- r . Air Standard&Optional Equipment 0 R95T Series REMOTE SENSOR DIRECT SPARK IGNITION& REMOTE SENSOR PRIMARY AND SECONDARY HEAT EXCHANGER 111�-�`u GAS VALVE AND MANIFOLD IN-SHOT BURNERS n a i "°-'�"`�a. .w"" DRAFT ..,�., INDUCER PRESSURE SWITCHES i 1} }!I! }1)f} BLOCKED DRAIN SENSOR CONSTANT TORQUE CONTROL __ �i1►}} r"` ELECTRICALLY BOARD COMMUTATED MOTOR STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired;blocked drain sensor,7 Side and bottom filter racks;return air cabinet for all sizes. segment LED and marked hoses;heat exchanger;primary: NOTE: Furnace is not listed for use with fuels other than natural aluminized steel,secondary:29-4C stainless steel;solid bot- or L.P,(propane)gas. tom;induced draft;pressure switches;redundant main gas All models can be converted by a qualified distributor or local control; blower compartment door safety switch;solid state service dealer to use L.P.(propane)gas without changing burn- time on/off blower control;limit controls;manual shut-off ers.Factory approved kits must be used to convert from valve;100%safety lock out;cool fan off delay;field selectable natural to L.P.(propane)gas and may be ordered as optional heat fan off delay;one hour automatic retry;power and self- accessories from a parts distributor. test diagnostics;flame sense current diagnostics;electronic For L.P.(propane)operation,refer to Conversion Kit Index Form. air cleaner connections;twinning(built-in)features;humidifier connections;humidifier on/off delay;low speed continuous fan option;single speed option for heating and cooling applica- tions;transformer;direct drive,multi-speed Constant Torque WARNING electrically commutated motor.(Please note:a thermostat is 1APPROVED not included as standard equipment.) THIS FURNACE IS 1' RECOMMENDED 1' USE IN MOBILEHOMES COMFORTINTEGRATED HOME f Q --on Air Physical Data&Specifications - 0 R95T Series Physical Data and Specifications-Upflow Models U.S.and Canadian Models MODEL NUMBERS R95T(-) R95T(-) R95T(-) R95T(-) R95T(-) R95T(-) R95T(-) 0401317MSA 0601317MSA 0701317MSA 0701521MSA 0851521MSA 1001521MSA 1151524MSA HIGH FIRE INPUT BTU/HR[kW] iD 42,000[12.30] 56,000[16.41] 70,000[20.51] 70,000[20.51] 84,000[24.61] 98,000[28.72] 112,000[32.82] HEATING CAPACITY BTU/HR[kW] 39,900[11.69] 53,200[15.59] 66,500[19.49] 66,500[19.49] 79,800[23.39] 93,100[27.28] 106,400[31.18] HIGH ALTITUDE OUTPUT 35,910[10.52] 47,880[14.03] 59,850[17.54] 59,850[17.54] 71,820[21.05] 83,790[24.56] 95,760[28.06] 10%DERATE[kW]HO BLOWER(DxW) 11x7 11x8 11x8 11x10 11x10 11x10 11x11 [mm] [279 x 178] [279 x 203] [279 x 203] [279 x 2541 [279 x 254] [279 x 2541 [279 x 279] MOTOR H.P.[W]- 1/2[373]-5- 1/2[373]-5- 1/2[373]-5- 1 [746]-5- 1 [746]-5- 1 [746]-5- 1 [746]-5- TYPE Constant Constant Constant Constant Constant Constant Constant Torque ECM Torque ECM Torque ECM Torque ECM Torque ECM Torque ECM Torque ECM MIN.CIRCUIT AMPACITY 8.00 10.00 10.00 12.00 13.00 15.00 14.00 MIN.OVERLOAD 15.00 15.00 15.00 15.00 20.00 20.00 20.00 PROTECTION DEVICE MAX.OVERLOAD 15.00 15.00 15.00 20.00 20.00 20.00 20.00 PROTECTION DEVICE MOTOR FULL LOAD AMPS 4.0 6.8 6.8 10.6 8.3 8.3 8.3 HEATING SPEED MED-LOW MED-LOW MEDIUM MED-LOW MEDIUM MEDIUM MEDIUM COOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGH HIGH MINIMUM EXT.STATIC PRESSURE 18[.045] .20[.050] .23[.057] .23[.057] .28[.070] .28[.070] .28[.070] (IN.W.C.)[kPa] MAXIMUM EXT.STATIC PRESSURE g[0.224] .9[0.224] .9[0.224] .9[0.224] .9[0.224] .9[0.224] .9[0.224] (IN.W.C.)[kPa] HEATING CFM @.2'[.049 kPa] 982[463] 913[431] 1113[525] 1351 [638] 1574[743] 1651 [779] 1524[719] W.C.E.S.P.[Us] COOLING CFM @.5"[.124 kPa] 1239[585] 1227[579] 1198[565] 1750[826] 1833[865] 1975[932] 1748[825] W.C.E.S.P.[Us] TEMPERATURE RISE-HIGH FIRE 25-55 35-65 40-70 30-60 35-65 35-65 45-75 RANGE IN DEGREES*F[°C] [14-31] [19-361 [22-39] [17-33] [19-36] [19-36] [25-42] APPROX.SHIPPING WEIGHT 123.5[56] 128[58] 132[60] 139[63] 147.5[67] 152[69] 165[75] (LBS.)[kg] AFUE sQ 1 95.00% 95.00% 95.00% 1 95.00% 95.00% 1 95.00% 95.00% NOTES: All models are 115V,60HZ,1 phase Gas connection size for all models is 1/2"[13 mm]N.P.T. iD Installation instructions for high altitude derate. OO Canadian installations only. OO In accordance with D.O.E.test procedures. *S=Standard Models NOTE:Standard model complies with California low NOx requirements. This furnace does not meet air district requirements of 14 ng/J NOx emissions limit,and thus is subject to a mitigation fee of up to$450.This furnace is not eligible for the Clean Air Furnace Rebate Program:www.CleanAirFumaceRebate.com. This furnace is to be installed for propane firing only in air districts requiring 14 ng/J NOx emission limits.Operating in natural gas mode is in violation of these Rules. [ ]Designates Metric Conversions COMFORT4 INTEGRATED HOME ,o Air Model Number Identification 0 R95T Series Model Number Identification R 95 T A — 040 1 3 17 M S A Rheem Series Motor- Design Series Input Stage-Single Airflow Cabinet Width Configuration- S=Standard Revision- 95% Constant A=1st Design BTU/HR 3-Up to 3 Tons 17=17.5' Multi-Position Marketing Efficient Torque B=2nd Design 040= 42,000[12.31 kW] 5-Up to 5 Tons 21=21.0° (A-First Time C=3rd Design 060= 56,000(16.41 kW] 24=24.5' Release) 070= 70,000[20.51 kW] 085= 84,000 124.62 kW] 100= 98,000[28.72 kW] 115=112,000[32.82 kW] [ ]Designates Metric Conversions COMFORTINTEGRATED HOME f Air Dimensional Data a R95T Series FRONT BOTTOM TOP A 121/32" I�15/8' [42 mm] I- [41 mm] B B OPTIONAL OPTIONAL VENT OUTLET She COMBUSTION AIR s/a" KNOCKOUT [8 mm] INLET KNOCKOUT [16 mm] [16 mm] SUPPLY AIR O 1927/32" A z4'/e" [504 mm] I [631 mm] 261/4" F [667 mm] 24" 237/32" 0 [633 mm] RETURN N [590 mm] 1925/32" [502 mm] 34" 6111 [864 mm] 9/32' [17 mm] C .� 13/4 I 121/32' [45 mm] Ir[42 mm] O A 263/,6"[665 mm] 253/,6"[656 mm] 295/6"[752 mm] 257/16"[646 mm] -*--281/16"[713 mm] 235/16"[593mm] OPTIONAL CONDENSATE 11/8" 1932/32"504 mm] 22s DRAIN(DOWNFLOW) OPTIONAL [ s/6^ /,s"[567 mm] CONDENSATE DRAIN [28 mm] [16 mm] (DOWNFLOW) ° OPTIONAL TRAP 2231/32" LOCATION [583 mm] (HORIZONTAL) pTIONAL ° 327/6" GAS CONNECTION GAS ° [835 mm] TRAP LOCATION CONNECTION (HORIZONTAL) 291/16" �- 2313/16" OPTIONAL COMBUSTION OPTIONALTRAP [605 mm] (HORIZONTAL)[738 16" VENT LOCATION LOCATION 291/32" [738 mm] OPTIONAL CONDENSATE C>� DRAIN(UPFLOW) aPTIDNAL VENT2fi1/e" r AIR INLET 171/2" is 83 mm] 177/,6" f [445 mm] [443 mm] --OP' LOW VOLTAGE CONDENSATE DRAIN 263/16" WIRING (UPFLOW) 181/8" 3221/32" [665 mm] 14" ELECTRICAL CONNECTION [461 mm] [829 mm] [356 mm] UNE VOLTAGE PTIONAL UNE VOLTAGE WIRING ELECTRICAL CONNECTION L LOW VOLTAGE J 225/s"1575 mm] 23"[584 mm] 243/16"[614 mm] 8" 111/32" 11" 8" [203 mm] [280 mm] [279 mm] [203 mm] 265/,6"[668 mm] RIGHT SIDE LEFT SIDE UNIT DIMENSIONS (CLEARANCE TO COMBUSTIBLES) MODEL LEFT MINIMUM CLEARANCE(IN.)[mm] SHIP FLANGE DIMENSIONS R95T SIDE RIGHT BACK TOP FRONT VENT WGTS. A 8 C SIDE 040 0 0 0 1 [25] 2[51] 0 123.5[56] 171/2[445] 1617/64[413] 1613/64[412] 060 0 0 0 1 [25] 2[51] 0 128 [58] 171/2[445] 1617/64[413] 1613/64[412] 070 0 0 0 1 1 [25] 2[51] 1 0 132 [60] 171/2[445] 1617/64[413] 1613/64[412] 070(wide) 0 0 0 1 [25] 2[51] 0 147.5[67] 21 [533] 1949/64[502] 1945/64[500] 085 0 0 0 1 [25] 2[51] 0 147.5[67] 21 [533] 1949/64[502] 1945/64[500] 100 0 0 0 1 [25] 2[51] 0 152 [69] 21 [533] 1949/64[502] 1945/64[500] 115 0 0 0 1 [25] 2[51] 0 165 [75] 241/2[662] 2317/64[591] 2313/64[589] *A service clearance of at least 24"is recommended in front of all furnaces [ ]Designates Metric Conversions Supply and return depicted as upflow configuration. Flange configuration will vary depending on installation orientation. INTEGRATED HOME COMFORT r BLOWER MOTOR MOTOR CFM[L/sl AIR DELIVERY FURNACE SIZE H.P. MOTOR LEAD WIRE SPEED EXTERNAL STATIC PRESSURE INCHES WATER COLUMN[kPal MODEL [mm) [W] TAP COLOR 0.1[.021 0.2[.051 0.3[.071 0.4[.101 0.5[.121 0.6[.151 0.7[.171 0.8[.191 0.9[.221 1 Red Low 874 [413] 820[387] 765[361] 71013351 658[311] 575[2711 523[247] 48212281 448[211] 2 Yellow Medium Low 1029 [486] 982[463] 930[439] 881 [416] 833[393] 780[368] 716[338] 665[3141 621 [293] (-)95T(-) 11 x7 1/2 3 Purple Medium 1098 [518] 1055[498] 1008[476] 962[454] 920[434] 870[411] 822[388] 755[3561 705[332] 0401317MSA 1279 x 178] 13731 4 Blue Medium High 1253.6 [592] 1209.1 [571] 1164.4[550] 1128.1 15321 1082.2[511] 1043.7[493] 1000[472] 960[453] 907.2[428] 5 Black High 1380.6 [652] 1345.5[635]1 1313.1 [620] 1276[602] 1239.2[585]1 1202.3[567] 1166[550] 1132.7[5351 1098.9[519] 1 Red Low 818 [386] 766[362]1 720[340] 668[315] 594[280] 548[259] 494[233] 444[210] 416[196] 2 Yellow Medium Low 968 [457] 913[431] 885[418] 841 [397] 796[376] 739[349] 685[323] 641 [3031 596[281] (-)95T(-) 11 X8 1/2 0601317MSA [279 x 203] [373] 3 Purple Medium 1018 [480] 981 14631 931 [439] 903[426] 860[406] 815[385] 756[357] 703[3321 656[310] 317M 4 Blue Medium High 1173 [5541 1142[539] 1108[523] 1059[500] 1025[4841 989[467] 951 [4491 912[430] 855[404] 5 Black High 1338 [631] 1327[626] 1288[608] 1245[588] 1227[579] 1193[563] 1165[550] 1134[5351 1099[519] 1 Red Low 820 [387] 701 [331] 642[303] 579[273] 508[240] 473[223] 415[196] 365[172] 289[136] 2 Yellow Medium Low 1068 [504] 1027[485] 976[461] 935[441] 897[423] 825[389] 758[358] 709[3351 656[310] 0701317MSA [279 x 203] [3773] () 11 x 8 1 3 Purple Medium 1219 [575] 1180[557] 1130[533] 1093[516] 1055[498] 1005[474] 967[456] 895[4221 842[397] 17M 4 Blue Medium High 1368 [6461 1311 [619] 1281 [605] 1239[585] 1209[570] 1174[554] 1129[5331 1091 [515] 1047[494] 5 Black High 1442 [680] 1407[664] 1380[651] 1342[633] 1306[617] 1269[599] 1233[582] 1188[5611 1147[541] 1 Red Low 1155 [545] 1095[517] 1044[493] 968[457] 906[4271 846[399] 766[362] 702[331] 643[303] (-)95T(-) 2 Yellow Medium Low 1453 [686] 1397[659] 1349[6371 1300[614] 1255[592] 1208[570] 1134[535] 1082[511] 1033[488] 0701521MSA 1279 x 254] [740 1 3 Purple Medium 1582 [747] 1532[723] 1481 [699] 1441 [680] 1400[661] 1358[641] 1309[618] 1247[5891 1187[560] (wide) 4 Blue Medium High 1744 [823] 1702[803] 1660[783] 1624[7661 1590[750] 1550[732] 1516[715] 1475[696] 1435[677] 5 Black High 1976 [933] 1934[913] 1895[894] 1860[878] 1826[862] 1794[847] 1752[827] 1659[7831 1553[733] 1 Red Low 1183 [5581 1128[532] 1062[501] 975[460] 899[4241 825[389] 754[356] 680[321] 627[296] 2 Yellow Medium Low 1482 [699] 1427[673] 1376[6491 1315[621] 1264[596] 1193[563] 1128[532] 1067[5031 1013[478] 08551521521MSA [279 x 254] [746] • 1 11 x 10 1 3 Purple Medium 1651 [779] 1611 [760] 1571 [741] 1518[717] 1476[696] 1434[677] 1383[653] 1311 [619] 1271 [600] M 4 Blue Medium High 1754 [8281 1718[811] 1680[793] 1631 [770] 1591 [751] 1554[733] 1501 [708] 1456[687] 1395 16581 • 5 Black High 2114 [997] 2082[983] 2049[967] 2009[948] 1974[9311 1940[916] 1903[898] 1821 [8601 1752[8271 • 1 Red Low 1187 [5601 1126[531] 1035[488] 963[454] 891 [421] 825[389] 754[356] 692[326] 633[299] 2 Yellow Medium Low 1490 [703] 1438[678] 1391 16571 1317[621] 1265[597] 1203[5681 1128[532] 1075[5071 1018[480] (-)95T(-) 11 x 10 1 1001521 3 Purple Medium 1738 [820] 1692[7991 1652[779] 1606[758] 1558[735] 1510[713] 1447[683] 1385[6541 1336[630] 521M MSA [279 x 254] [746] 4 Blue Medium High 1791 [8451 1757[829] 1707[806] 1661[784] 1618[7631 1562[737] 1509[712] 1457[688] 1408[665] 5 Black High 2137[1009] 2102[992] 2062[973] 2020[9531 1975[932] 1946[918] 1908[900] 1817[8581 1685[7951 1 Red Low 1219 [575] 1153[544] 1078[509] 1001 [4731 904[427] 824[389] 756[357] 677[320] 615[2901 2 Yellow Medium Low 1522 [718] 1451 [685] 1395[658] 1327[6261 1264[5961 1203[568] 1131 [534] 1049[495] 991 [468] (-)95T(-) 11 X11 1 3 Purple Medium 1679 [792] 1625[7671 1570[741] 1521 [7181 1465[691] 141516 1357[640] 1306[616] 1239[585] 1151524MSA [279 x 2791 [746] 4 Blue Medium High 1798 [848] 1751 [826] 1697[8011 1658[783] 1609[759] 1555[734] 1507[711] 1448[6831 1394[6581 Jb6 5 Black High 2133[1007] 2101 [992] 2046[966] 2004[946] 1963 19271 1919[906] 1882[888] 1833[865] 1765[833] b a This table is for reference. The technician/installer must verify furnace is operating within the published rise range before completing the installation. M co � o [ ]Designates Metric Conversions. w N O E3 W 0 CD 0 w w a Air Accessories a R95T Series VENT TERMINATION KITS: = FOR HIGH ALTITUDES: RXGY EO2:Vertical/Horizontal Concentric Vent Termination Kit NOTE:For Canadian installations only,an optional Berate(manifold 2" Pipe(US Only) gas pressure reduction)method may be used to adjust the furnace for altitude.See Installation Instructions for more RXGY EO2A:Vertical/Horizontal Concentric Vent Termination Kit information.This optional method may NOT be used for U.S. 2�� Pi US a &Canadian p y Pipe( ) installations.See installation instructions as appropriate orifice RXGY-E03:Vertical/Horizontal Concentric Vent Termination Kit change is required. 3"Pipe(US Only) RXGY-EO3A:Vertical/Horizontal Concentric Vent Termination Kit L.P.CONVERSION KIT.RXGJ-FP38 3"Pipe(US&Canadian) CONDENSATE PUMP KIT:PROSTOCK&1 PC13151 TUL RXGY G02:Direct Vent Furnace Side Wall Vent 2"or 3"(US Only) DOWNFLOW/HORIZONTAL CONVERSION KIT.RXGY CK RXGY D05:Combustion Air Drain Kit 2" DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE CONVERSION KIT:RXGY-ZK RXGY DO6:Combustion Air Drain Kit 3" COMBUSTIBLE FLOOR BASE:RXGC-1317 NEUTRALIZER KIT.RXGY-A01 RXGC-1321 (Replacement Cartridge 54-22120-01) RXGC-1324 EXTERNAL BOTTOM FILTER(UPFLOW/HORIZONTAL)RACK: RXGF-CB [ ]Designates Metric Conversions EXTERNAL SIDE(UPFLOW)FILTER RACK:RXGF-CD EXTERNAL(DOWNFLOW)FILTER RACK:RXGF-CC FILTER RACK FILTER SIZES`INCHES[mm] RXGF-CB RXGF-CD RXGF-CC MODEL (UPFLOW/ (UPFLOW) (DOWNFLOW) HORIZONTAL) R95T(-)040 153/4 x 25 153/4 x 25 14 x 20 1400 x 6351 [400 x 635] [356 x 5081 R95T(-)060 153/4 x 25 153/4 x 25 14 x 20 [400 x 635] [400 x 635] [356 x 508] R95T(-)070 153/4 x 25 153/4 x 25 14 x 20 [400 x 635] [400 x635] [356 x 508] R95T(-)070 191/4 x 25 153/4 x 25 12 x 20 (wide) [489 x 635] [400 x 635] [305 x 508] R95T(-)085 191/4 x 25 153/4 x 25 14 x 20 [489 x 6351 [400 x 635] [356 x 508] R95T(-)100 191/4 x 25 153/4 x 25 14 x 20 [489 x 635] [400 x 635] [356 x 508] R95T(-)115 223/4 x 25 153/4 x 25 14 x20 [578 x 635] 1400 x 635] [356 x 508] INDOOR COIL CASINGS MODEL NUMBER RXBC-D17A1 RXBC-D21A1 RXBC-D2161 RXBC-D24A1 COMFORTINTEGRATED HOME c i -Air Limited Warranty 'a R95T Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required)...............................Ten(10)Years period stated,in accordance with the terms of the limited Heat Exchanger.........................................Limited Lifetime warranty. Tor complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. INTErRATED HOME COMFORT Air Notes "a R95T Series INTEGRATED • COMFORT a 1 .. The new degree of comfort: In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice. Rheem Heating,Cooling&Water Heating 5600 Old Greenwood Road Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72908 www.rheem.com Brampton,Ontario • L6Y 0135 INTEGRATED HOME COMFORT PRINTED IN U.S.A.6/21 OG FORM NO.G11-538 REV.14 YOU ] riOLP GENERAL NOTES CONCRETE FIN15H NOTE5 1. ALL WORK 15 TO CONFORM r0 THE RULE5 AND REGULATIONS OF THE I. ALL CONCRETE WORK SHALL CONFORMW/174 THE REQUIREMENTS OF THE 4. BEAM CONNE6TION5 SHALL BE DESIGNED TO WITHSTAND ONE-HALF THE I. PAINTING OR INTERIOR FINISHING SHALL NOT BE DONE UNDER CONDITIONS LOCAL BUILDING DEPARTMENT AND THE N.Y.5. RE5/DENTIAL CON5TRLlCTION AMER/GAN CONCRETE IN5TITUTE A.G.I. 3/8 LATE5T EDITION. MAXIMUM ALLOWABLE UNIFORM LOAD FOR THE PARTICULAR BEAM AND WHICH WILL JEOPARDIZE THE QUALITY OR APPEARANCE OF 5VCH WORK. CODE. NO NOTE OR DETAIL OR LACK THEREOF 5HALL BE GON5/DERED 2. CONCRETE CONTRACTOR TO 5ET AND PLACE FORMS WITH STRICT SPAN CONDITIONS SHOWN OR THE LOAD INDICATED ON DRANIN555, WORKMANSHIP,WHICH 15 JJDGED LE55 THAN FIRST QUALITY BY THE AS RELIEVING THE CONTRACTOR FROM EXECUTION OF ALL WORK IN ATTENTION AND CARE TO ALL DATUM, FLOOR AND GRADE ELEVATIONS. WHICHEVER 15 GREATER. ARCHITECT,WILL BE RE.ECTED. ACCORDANCE WITH ALL 57ATE AND/OR LOCAL CODE-5. 3. CONCRETE PROTECTION FOR REINFORCEMENT 5HALL CONFORM r0 LATE5T 5 HELDING 5HALL BE IN ACCORDANCE WITH Ah6 5FE61FICATION5 U5IN57 2. 5YBMIT GOLOR5 TO 774E ARCHITECT, FOR AFFROVAL. 2 ALL ELECTRICAL WORK r0 BE FIRE UNDERWR/TER5/N5PEGTED AND A.G.I. SPECIFICATION. E70 XX ELE5TRODE5. APPROVED. 5UBM/T GERTIFICA7E TO OWNER UPON RECEIPT. 4. ALL TEMPERATURE REINFORCING 5HALL BE 5UFFICIEN77-Y EMBEDDED TO 3. PREPARE 5URFAGE5 r0 RECEIVE THE 5PECIFIE9 FINISH. TAPE AND 5AMJ 3. ELEc,m1cAL CONTRACTOR TO VERIFY ELECTRICAL 5ERVICE AND PARCEL DEVELOP FULL 5TRENGTH IN ALL CONCRETE WALL5 AND 5LA55. 6. ALL BOL T5 5HALL BE A5774 A-325N AND 5HALL BE INSTALLED TO A 5NU5_l 5MOOTH GYP5UM BOARD TO RECEIVE THE SPECIFIED FIN15H. PAINT GRADE 11 b 10 MAI/I bAXVI EW RPO FOR ADEQUACY IN PROV/DING NEW ELECTRICAL 1N5TALLATION5 A5 5 PROVIDE ADEQUATE TIE5 FOR ALL STEEL REINFORCED IN 5LAB5,BEAM5, CONDITION A5 DEFINED IN AI5C 5PEC1FICATION5. WOODHORK 5HALL BE HAND 5ANDED BETWEEN COA75 AND VV57F9 GLEAN. SHOWN ON THE PLANS. UPGRADE, SERVICE, METER AND PANEL A5 MAY P/ERR5, AND AAL.L5, REINFORCED TO BE HELD AT CORRECT P15TANGE FROM ALL HOLES, PITCH POCKETS OR 5APPY PORTION5 SHALL BE SCRAPED AND 7. ALL WELDERS SHALL BE CURRENTLY CERTIFIED. THE FOLLOWING 5HELLAGKED, BE REQUIRED. FORMS AND EARTH BY STLfL CHAIRS OR TIES. CERTIFICATIONS ARE ACCEPTABLE. NEW YORK 5TA7F NEW YORK CITY 4. ALL PLUMBING WORK TO BE IN 57R/CT ACCORDANCE WITH N.Y.5. CODE 6. FOLLOW C.R5.1. RULES FOR PLACING ALL REINFORCING 57EEL AND DEPT: OF BUILDINGS, OR TESTING LABORATORY CERTIFICATION TO THE AA5 4 FILL CRACKS, HOLES, IMPERFECTIONS IN EXI5TIN57 WAL.L5, PARTITION5, OR AND ALL APPLICABLE LOCAL RE5ULATION5. ACCESSORIES. CODE. GYP5UM BOARD WITH PATCHING PLASTER AND SMOOTH OFF TO MATCH TOW/1 oryoUTHOLP5 CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, IF CON7RACTOR5 7. CONTRACTOR SHALL SUBMIT CONCRETE MIX REPORT WITH PAINTING ADJOINING SURFACES OR LAMINATE WITH I LAYER OF 1/2"GYP5bM BOARD LIABILITY,WORKMANS COMPENSATION, COMPLETED OPERATIONS, ETC. COMPRESSION 7E5T RE5UL r5 r0 ENGINEER FOR REV/EW PRIOR TO TO ACHIEVE REQUIRED 5MOOTHNE55,A5 PER ARGHI7EGT5 IN5PEGTION.ADEQUATE FOR THESTARTING FOUNDATION GONSTRI/GTION.PURP05E5 OF THIS PROJECT AND FURN/5H PROOF OF /. ALL 5TEEL AFTER FABRICATION SHALL BE THOROUGHLY GLEANED OF RUST, 5. WIPE NEW 6YP5tM BOARD SURFACES WITH A DAMP CLOTH 16T PRIOR TO 5AME TO THE OWNER PR/OR TO COMMENCING W/TH WORK. 0. REPRE5ENTATIVE TE5T GYLINDER5 5HALL BE TAKEN FROM THE CONCRETE DIRT,LOO5E MILL 5CALE,AND OTHER FOREIGN MATTER AFTER GLEAN/NG, APPLICATION OF THE PRIMER, IN ORDER TO LAY FLAT ANY NAP WHICH MAY PLACED EACH DAY IN ACCORDANCE WITH CONCRETE SPECIFICATIONS. STEEL SURFACES SHALL BE SHOP-PRIMED WITH ONE COAT OF METAL HAVE FORMED IN SANDING PROCESS. /® Y , 6. EACH AOE(Y7 RKMA R SHALL SUBMIT N COPY OF 74/5 INSURANCE TESTING 5HALL BE PERFORMED AT 7 AND 28 DAYS PRIMER AND ONE COAT COLOR TO BE 5ELEG7ID BY OWNER PAINT GOAT5 COVERAGE(WORKMANS COMPENSATION, LIABILITY,D15AB/CITY) TO SHALL BE FULL PETTING,APPLIED THOROUGHLY AND EVENLY TO THE 6. UPON COMPLETION OF PAINTING WORK, REMOVE ALL PAINT FROM WHERE IT THE OWNER PRIOR TO COMMENCING WORK EACH 5UBGONT RACTOR 5HALL q. ALL MESH SHALL BE 5PLICED 50 7HAT THE OVERLAP BE77'EEN OUTERMOST 5URFAGE5,AND FREE FROM 5PRAY DU5T, RUN5 OR 5AC5. HA5 5PILL)Eb 5PLA5HED, OR 5PLATIERED ON EXPOSED ADJACENT 5U9M/T LIEN RELEASES PRIOR TO RE01155TIN57 FINAL PAYMENT. CRO55 W/RE5 OF EACH 5HEET 15 NOT LE55 THAN THE 5PAGIN57 OF THE 5URFAGE5. A. AREA QTY. QUANTITY 7 CONTRACTOR 5HALL AT ALL TIME5 PROCEED WITH WORK A5 TO MINIMIZE CRO55 WIRE5 PLU5 TWO INCHES, UNLESS OTHERWISE SHOWN ON THE 2• PRIMER 5HALL BE RUST-O-LEVM Iobq RRV5T-INHIBITIN5PRIMER OR SYMBOL DE5GR/PT/ON 5YMB0L D55CR/PT/ON A.B. ANCHOR BOLT RAD, RA19/16 THE OWNER5 INCONVENIENCE,AND SHALL DO 501N A NORKMAN-LIKE DRAWING. APPROVED EQUIVALENT. SECOND GOAT SHALL BE RUST-0-LEUM 1060, OR 7 EXAMINE FIN15H 5UIRFAGE5 AFTER COMPLETION OF WORK INCLUDING A.G.I. AMERICAN R.D. ROOF DRAIN MILLWORK INSTALLATION AND PROCEED WITH "TO!/GHI/P"AS REQUIRED CONCRETE MANNER APPROVED EQUIVALENT. REGPT. RECEPTACLE lO. ALL FG�JNDATIONS SHALL BE CAST ON UND/57l/RBED OR CONTROLLED INSTITUTE 8. ALL SALVAGEABLE MATERIALS AND EQUIPMENT INCLUDING FIXTURES A.D.A. AMERICANS W/774 INF REINFORCING SRN/SH/NG5 AND DECOR ITEM5 SHALL BE STORED AND PROTECTED FROM COMPACTED 50/L HAVING A M/N/MUM BEARING CAPACITY OF TWO(.2) TONS 3 AFTER ERECTION, TOUGH IIP ALL FIELD GONNEGT10N5 AND ABRADED 8. Pl?OVIDE ARCHITECT W/THAM/N/I4UM OF(3)8"X lO"BRUSH-OUTS OF EACH DISABILITIES ACT DN. DOWN PER 5GWARE FOOT UNLE55 OTHER415E NOTED(SUBJECT TO FIELD 50RFACE5 H1774 SAME TYPE OF MATERIAL U5EU FOR 5HOP COATING. COLOR AND FIN15Hl FOR ARGHI7FCr5 APPROVAL,AT LE45T 2 WEEK5 PRIOR SEC TION hO7 SEE ELE�/A TION TAG- ADH ADHESIVE TAKEN WITH SAME.DR DOOR DAMAGE UNTIL THE OWNER DETERM/NES THE COURSE OF ACTION TO BE INSPECTION AND VER/FIGATION BY CONTRACTOR) TO 5/TE APPLICATION. ON 517E APPLICATIONS 5HALL BE REQUIRED ONE X DWG. A5 NOTED X D77- DETAIL X-X 5EE DING. A5 NOTED A.FF ABOVE FLOOR DWG. DRAWING WOOD WEEK PRIOR TO FINAL APPROVAL. ARCHITECT RE5ERVE5 THE RIGHT TO FINISHED FL DWLS. DOl'EL5 q. PROTECT AND MAINTAIN EXISTING UTILITY LINE5 WHICH ARE TO /I. MAX/MUM 57EP OF FOOTINGS SHALL BE ONE VERTICALLY TO 7TV0 A016T ANY COLOR/FINISH ONCE THE WALL TE5T HA5 BEEN MADE. ALT ALTERVA� REMAIN IN 5ERVICE IN SUCH A MANNER A5 TO AVOID INTERRUPTION OF HORIZONTALLY WHERE ELEVATIONS CHANGE. 1. ALL LUMBER 5HALL BE DOII5LA5 FIR LARCH No. 2, FB = 675 P5I, FV= 95 9 ALJALUM. ALUMINUM EA. E THESE LINE5. UNLE55 OTHERN15E NOTED,ALL EXISTING UT/LIT/E5 5HALL BE P51, E= 1,600,000 P5/, MAXIMUM MOl5TURE- CONTENT<lq�. . FINISH UNDERSIDE SOF SOFFITS(WHERE THEY OCCUR) TO MATCH ADJACENT E ANOD. ANODIZED l•F.S. EXTERIOR INSULATION AL TERED, GAPPED, OR RELOCATED IN A MANNER APPROVED BY THE 12. ALL RETAINING WALL5 SHALL BE ADEQUATELY BRACED DURING VERTICAL FINISH, U O.N. A.N.5.1. AMERICAN FIN15H 5Y57EM CON57RRZTION r0 MAINTAIN 5AFETY AND STAB/LITY. BACKFILLING SHALL 2. ALL STUD LUMBER SHALL BE DOUGLAS FIR LARCH STUD GRADE, FB = 675 IO INSTALL ELECTRICAL 5AlTGH AND OUTLET COVER PLATES, SURFACE x TAG- 5EE DING. FIN15H TAG- 5EE FIN15H NATIONAL GOVERNMENTAL AUTHORITIES AND UTILITY GOMPAN/E5 HAYING.NIR/SDIGTION STANDARD5 ELEG/ ELECTRIC/-AL NOT BE PERMITTED UNTIL CONCRETE H45 ACHIEVED q0� OF THE SPECIFIED P5/, FV= q5 P5/,E_ 1,400p00 P5/, MAXll4(IM MOISTURE CONTENT C lq�;. HARDWARE,ETC.,AFTER PAINTING AND/OR APPLICATION OF WALL x-x AS NOTED X-X LEGEND $ CEILING FIN. ELECT. 50 A5 TO GUARANTEE A COMPLETE INSTALLATION. INSTITUTE ELEV/EL. ELEVATION DE5IGN 5TRENG7N LEGEND APPROX.. APPROXIMATE ll. CONTRACTOR 5HALL PROTECT, PATCH AND REPAIR ALL EX/STING WORK 3. ALL WOOD CON5TRU5TION SHALL COMPLY WITH 774E NATIONAL DESIGN COVERINGS AND CARPET. ENS. 1 lGINEER/ED 5PECIFIGATION FOR hOOD CON57RI 6TION,LATE5T EDITION. ARCH. ARCH/7FGT/ EQ E�� ADJACENT TO 74/5 WORK, OR DAMAGED A5 A RESUL r OF 74/5 WORK. l3. ALL CONCRETE SHALL ATTAIN A M/N/MUM STRENGTH OF 3,000 P5/® 28 /l. MODIFY EXISTING FLOOR SURFACES, TO RECEIVE NEW FLOORING MATERIALS -URAL WHERE EXISTING MATERIALS ARE TO BE MATCHED, CARE 15 TO BE DAYS. FOUNDATION, 5LAB5 ON GRADE AND CONCRETE EXPOSED TO PLUMBING AVG' AVERAGE EQUIP EQUIPMENT TAKEN IN BLENDING COLORS AND REPLICATING ADJACENT FORM5 AND AEATHERR 5HALL BE AIR ENTRAINED. 4. ALL WOOD EXPOSED TO WEATHER 5HALL BE CGA TREATED IN TO PREVENT NOTICEABLE LUMPS AND DEPRE55/ON5. B.O. BOTTOM OF ETC. ETCETERA CONTOURS. ACCORDANCE WITH AFPA STANDARDS. 12. PARTITIONS AND MILLWORK TO RECEIVE 5TRA16HT RE51LIENT BASE OR ELE1/ATION X_X ACCESSORIES TAG- BD. BOARD EXIST. EX15TIN& l4. ALL CONCRETE RE/NFORCINS STEEL 5HALL BE IN ACCORDANCEW/TH ASTM BLDG. BUILDING I2. BEFORE 50BMITT/NG ANY PROPOSAL, I 5HALL BE THE RE5PON5/B/LITY " " " CARPET, COVE RE5/LIENT BA5E AT RESILIENT FLOORING. U.O.N. BENCHMARK 5EE AGGE550RIE5 EYP '�� OF THE CONTRACTOR r0 FAMILIARIZE HIMSELF W/7H ALL LXl5TlNG A-6/�GRADE 60 DEFORMED BARS. 5. ALL WOOD CONNECTORS SHALL BE BY 5IMP50N, TECO, OR B.F.P. BACK FLOW EXT EXTERIOR APPROVED EQUAL. l3. 5TAl1VED AND PAlRW1FD SURFACES SHALL BE FINISHED SUCH THAT JOINTS LEGEND PREVENTOR FD. FLOOR DRAIN COND/TION5, MATER/AL5 TO BE MATCHED, WORRKING SPACE AVAILABLE, l5 1NELDED WIRE ME5H 5HALL BE IN ACCORDANCE WITH A5TM A-185 ELK. BLACK PDN. FOUNDATION SAFETY PRECAUTIONS,ETC. REQUIRED FOR 774E SAFE AND EXPEDITIOUS 6. MEMBER5 DE516NA1F9 AS "GANG LAM"OR 1AMlN.A7F9 VENEER LUMBER"OR ARE NOT VI51BLE WHEN VlB'ED FROM ANY RE45ONABLE ANGLE. BLKG. BLOCKING FIN. FIN/5H EXECUTION OF TH/5 CONTRACT. FAILURE TO DO 50 WILL NOT BE 16. ALL 57RU67URAL MEMBER5 5HALL BE POURED FOR THEIR FULL DEPTH5 IN "LVL"SfI,ALL BE MANUFACTURED 174 ACCORDANCE Wl1H SPEGIFIGArIONS BY 14. WALL COVERING SEAMS SHALL NOT OCCUR WIT�IIN l"-O"OF CORNERS. EXTERIOR FIN15H TAG- BRO. BEAR/NG FIXT FIXTURE CAL15E FOR EXTRA C05T5 r0 774E OWNER OR OWNER5 REPRE5ENTATIVE5. ONE OPERATION. CON57R/IGTION JOINTS SUCH A5 A DAY5 POUR JOINTS ROOM ROOM NUMBER 5EE EXT. MATERIAL BTM. BOTTOM RLR. FLOOR . NO 5UBSTITUTE5 SHALL BE PERMITTED WITHOUT APPLY FABRIC 50 WALL I5 DIVIDED WITH A MINIMUM NUMBER OF 5EAM5, CONTACT THE ARCH/7EGr I14MED/A7ELY IF FIELD CONDITIONS ARE SHALL BE LOCATED IN THE MIDDLE OF THE SPAN MAIN RE/NFORGING TO LCV15/ANA PACIFIC CORP XXX TAG BTN. BETA fN FRZ. FREEZER THE ENGINEER5 APPROVAL. DE51CN 57RE55E5 ARE A5 FOLLOWS: FB = AND WITH EQUAL A/D7H PANELS, U.O.N. FOUND TO BE OTHER THAN 77405E SHOWN HEREON PRIOR TO PROGEED/NG RUN THROUGH THE JOINT, KEY AND RGIIGHEN JOINTS TO EXPOSE LEGEND/5/TE GAB. CABINET OTNO WITH WORK AFFECTED BY 5A ME AGGREGATE FOR CHEMICAL BOND 2,gSOPSI, FV=2gOP5/,E=2,000.00OPSI 15. LOCATE INTER5EGTION5 OF DIFFERENT FLOOR FIN/5H MATERIAL5 DIREc7LY G.G.F G014PAG7FD GA. GASE/GUAGE GRANULAR FILL 13. CONTRACTOR SHALL VERIFY ALL D/MEN51ON5 PRIOR TO 7. THE ARCHITECT 5HALL PROVIDE CALCULATION5 TO THE CONTRACTOR FOR UNDER CENTER OF DOCR5, U.O.N. GAL. GALLON l7. NO HORIZONTAL JOINT5 5HALL BE PLACED IN WAL.L5 EXCEPT A5 SHOWN ON G.J. GQN7ROL JO/NT FABRICATION. VERIFICATION OF LOAL75 AND BEAM 5/ZE5 WITH IFR. PRIOR TO ORDERING GALV. GALVANIZED 774E DRAAING5,WITHOUT THE APPROVAL OF THE ENC71NEER. 16. SUBMIT CARPET 5EAMIN6 PLAN(FOR BROADLOOM) TO ARCHITECT PRIOR TO DOOR TAG PROPOSED WALLS G.L. CENTER LINE G.G. GENERAL l4. DI5CREPANG/E5ERRORS OM/55/ON5 ETC. IN ANY PORTION OF THE AND MAM/FAG7URE NOTIFY ARCHITECT OF ANY DlSGREPANGlES, IN WRITING, GLC. CEILING CONTRACTOR SHOULD THERE BEA PROBLEM. ORDERING AND AT LEA5T(4)AEEK5 PRIOR TO IN5TALLATION FOR SCHEDULE � REFER TO FLOOR CLOS CLOSET GD. GRADE DRAW/NGS WH/GH AREA VARIANCE WITH 774E LAW GRD/NANGES, RULES /8. MAX/NNM L17VG1H5 OF FOI/NDATION WALL POUR IN ONE OPERATION SHALL O ARGH1TEGr5 RREVIEW AND APPROVAL. DOOR SCh'D. PLAN5 FOR 51ZE Cl-R. CLEAR CL. GLA55 OR REGULATIONS,BEAR/NG ON THE CONDUCT OF THE SHALL BE BE NO MORE THAN TWO GONSEGUTIVE COLUMN DIM. OR 60 FEET 6. THE CONTRACTOR SHALL BE RE5PON5/5LE FOR COORDINATING ALL COL. COLUMN GYP. GYPSUM REPORTED PROMPTLY TO 774E ARCH/7FCT. REQUIRED INSPECTIONS OF 774E ROUGH AND FINAL FRAMING l7. METAL DOORS, CONVECTOR COVER5, FRAME5 AND AAL.L5 A5 5PE61FIE9, CONI. CONCRETE H.G. HANDICAP l5 IF COND/TIONS ENCOUNTERED PUR/NG CONSTRUCTION DIFFER 19. CONCRETE CONTRACTOR TO BE RE5PON5/BLE FOR SETTING ALL ANCHOR TO RECEIVE A PAINT FIN15H 5HALL BE PAINTED A5 FOLLOWS: PROP05ED DOOR CONS. CONDUIT ACCESS/BLE BOL T5 AND LEVELING PLATES. HINDOH TAG- CONN CONNECTION H.G. HOLLOW GORE FROM WHAT 15 SHOWN ON DRAW/NG5, THE ENGINEER SHALL BE q, REFER TO DRAWING G5-2 FOR DE5/GN LOADS GYP5bM.• REFER TO FLOOR CONST. CON57RZTI0N HD. H/GH DEN5/TY NOTIFIED 1M4E9IATEL.Y AND WORK SHALL NOT PROGRESS L/NTIL 20. PROVIDE GONTINUOU5 2x6 TREATED 5/LL PLATE OVER 7ERM/7E SHIELD FIR5T GOAT: LA TEX PR/MER O SCHEDULE HDR. HEADER TIED INTO FOUNDATION WALL5 W/TH 5/8"ANCHOR BOL r5 3'-O"o.c. (l'-0" l0. ALL CONGEALED 5PAGE5 IN WOOD FRAMING 5HALL BE FIRESTOPPED WITTY 5ECOND GOAT LATEX EGGSHELL DOOR SChD. PLAN5 AND SGHED. GONr. CONTINUOUS ALL PROBLEMS ARE RESOLVED To 77-IE SA OF 77�E HDW. HARDWARE t CONTR. CONTRACTOR HDkV HARDWOOD ENG/NEER MAX. FROM ALL CORNERS)WITH l0"m/n EMBEDMENT. PROVIDE SILL WOOD BLOGKIhIS AGGL/247FL Y FITTED TO FILL THE OPENING AND ARRANGED THIRD GOAT: LATEX EGGSHELL FOR SIZE G.T. CERAMIC TILE H.M. 090 MET l6. ALL SUBGON77ZAGTORS SHALL BE RESPONSIBLE FOR FILING AND SEALER AND GROUT 5/LL PLA7F TO WALL. r0 PREVENT DRAFT5 FROM MOVING FROM ONE 5PACE TO ANOTHER. METAL DOORS FRAMES. GONVEGTORS: PROPOSED G.SJ. CON577RIIGTION CO�T�S%o 5PECIFIGATION HT. HEIGHT OBTAINING APPROVAL5 FOR THEIR WORK WH/GH MAYBE REQUIRED. 2I• FLOOR 5LAB5 ON GRADE TO BE 4"POURED CONCRETE WITH 6x6/1.4X1.4 5A. ll. PROVIDE BRIDGING 8'-0"o.c. MAX(SOLID OR CRO55 BRIDGING). FIRST GOAT LATEX METAL PRIMER Q REV15ION TAG �� FIXTURE5 FOR 1N5T17UTE RV.A.G. HEATING, l7. ALL 5U56ONTRACTOR5 SHALL PROVIDE ALL EQUIPMENT, TOOL5, FENGE5, HIRE RE/NFORGINS AND STEEL TROWEL F/N/574 PROVIDE l/2" 5EGOND GOAT LATEX 5EMl GL055 E94MEL GU. CUBIC VENTILATION A/R TRANSPORTATION, SAFEGUARDS,ETC.,A5 REQUIRED FOR THE PROPER THIRD GOAT LATEX 5EMl CX 055 ENAMEL FUTURE COND/TION/If5 PREMOULDED EXPAN51ON JOINTING AT FLOOR SLAB AND FOUNDATION 12. NOTCHES OR HOLE5 FOR PIPING ETC. IN 57RUCTURAL FRAMING MEMBER5 ITEC. DG','/BLE EXECUTION OF 171E/R WORK. DEG. DEGREES LG. 15CLATED GROUND /6. ANY DEVIATION5 FROM THE ARCHITECTS DRAWINGS MUST BE SHALL.UBMITTED L• PROVIDE 2"(R-lO m/n)R/G1D INSULATION 2'-O"EACH WAY (`OR 5HALL NOT BE PERMITTED. l8. PAINT 5HALL BE LATEX- INTERIOR FIN15HE5 TO COMPLY WITH LOCAL COMBO CARBON MONOXIDE DIA. DIAMETER IN6HE5 r0 THE ARCH17ECTIN WR/TING FOR APPROVAL. HEATED SPACES). BUILDING CODE AND 5HALL BE INTERIOR FIN15H GLA55 G FOR CORRIVOR5 5MOKE DETEC TOR DIM. DIMEN5/0N INCL. /NGLUDEE9 /3 DOUBLE J015 T5 UNDER ALL PARTITIONS RUNNING PARALLEL WITH 774E J015 T5 AND ROOM5. SMOKE DETECTOR SHALL BE LLED N57AINFO. INFORMATION lq. EACH CONTRACTOR AND 56000NTRA67OR SHALL BE RE5PON5/BLE FOR 22. ALL 5LAB5 ON GRADE 5HALL HAVE THI6KEN/N55,DEPRE55ION5, (i) SHALL BE HARDWIRED INT INSULATION /N5TL. INSTALLATION/ MAINTA/N/NG SAFETY ON THE JOB 5/TE DURING THE CON57RUCTION OPEN/N55 ETC. A5 REQUIRED OR A5 5HOWN HEREIN OR ON HARDWIRE, TO CENTRAL INT. INTERIOR NSTA /4. ALL FLOOR AND SKYLIGHT OI'ENlNG5 ARE TO BE FRAMED Wl7H DOABLE l9. INTERIOR FINISHES SHALL BE GLA55/PIED IN ACCORDANCE WITH SURFACE SYSTEM WITH BATTERY To CENTRAL 5Y5TEM J-BOX .NINGTION BOX ;REQD IREI7 PHA5E TO COMPLY W/TH 774E REGULATIONS AND REGUIREMENT5 OF THE AR6H/7F67URAL DRAA/N5FULLY 5. HEADER5 AND TRIMMER5, LY JOINED WITH 57FEL BRIDGE5 OR "TFC05". FLAME RAT/N55. ALL FINI5HE5 1N THE FROP05ED AREA TO BE INTERIOR WI TH BATTERY BACKUP 16TJ015T OCCUPATIONAL 5AFETY AND HEALTH ADMIN15MATION. 774/5 5HALL FIN15H GLA55 B. FINI5HE5 MATERIAL 5HALL HAVE FLAME-SPREAD RATING JT. JOINT RM. ROOM 23. PROVIDE POCKETS IN WALL FOR COLUMNS,BEAM5 AND 5LAB5. BACKUP INCLUDE,BUT ARE NOT LIM/TED TO: PROVIDING ALL NECESSARY 0 " 15. TO ELIMINATE THE HAZARD OF M0157URRE CONDENSATION IN GOLD WEATHER OF 26 TO 75 SMOKE DEVELOPED RATING OF GLASS B. IN 56PPLIER R.O. ROUGH OPEN/NG M/N/141JM BEAR/NG ON WALLS OR BEAMS: 4 FOR SLABS, 8 FOR BEAMS, //�I/ � / LAM. LAMINA TE R.T.U. ROOF TOP LIN/T TENIPOR.ARY SUPPORTS AND BR,AGING AS MAYBE REQUIRED PRIOR TO U.O.N. AND TO PERMIT THE ESCAPE OF HEAT IN HOT WEATHER. VENTII}ITION OF �/ / LAV. LAVATORY 5AN. 5AN/TARY THE 774E INSTALLATION OF NEW STRUCTURAL ELEMENT5,A5 WELL A5 ATTIC AND CRAWL SPACES 15 REQUIRED. BLOCKING AND BRIDGING 5HOULD 20• ATTACHMENT AND AOHE51VE5 FOR INTERIOR LOCATIONS,WHICH WILL LBS. POUNDS 5.C. SOLID GORE ADEQUATE AND PROPER BARRR/GADE5, RAILIN575, LIGHTING, 5TAIR!S ETC. 24. TOP ELEVATION OF 5LAB5 5HALL VARY ACCORD/NG TO FIN15H FLOOR BE ARRANGED 50 A5 NOT TO INTERFERE WITH 774E MOVEMENT OF AIR. PRODUCE PRODUCT5 MORE TOXIC THAN TH05E LIVEN OFF BY WOOD OR L.F. LINEAL FOOT 5CH9. 5Cl-IEDULE REQUIRED TO PROTECT THE WORKMAN, OWNER5 PER50NNEL AND MATERIAL. 5EE ARCH17ECTURAL DRAW/NG5. PAPER WHEN DECOMP051NO OR BURNING MILL BE REJECTED. ARCH/TECTUBAL: 5EGT. SECTION OTHER5 FROM INJURYDUE TO GON57RUGTIONWORK. PROVIDE FREE L.P. LOW PO/NT 25. IN ANY APPROVED CONSTRICTION JOINT, PROVIDE 2'X 4"KEY MIN. AND 24 /6. All GA71/EDRAL GE/L/NG5 SHALL HAVE CONT/1JUOYIS TIENT/LAT/ON FROM 2I• ALL NEW OR MODIFIED CON57RZTION SHALL BE FIN15HED A5 PER OWNERS' C5-I - GENERAL NOTE5, LEGENDS DRAINING L/5T $ ABBREVIATION5 MAIL. MATERIAL S.F. SQUARE FEET AND 5AFE PA55ASE FOR PERSON5 TO AND FROM AREA5 AND EAVE5 r0 RIDGE SIZE INSULATION ACCORDINGLY. PROVIDE 3/4"dla. VENT MAX. MAXIMUM 5HT. SHEET FACILITIES WN/GH ARE TO REMAIN. BAR DIAMETER LAP(l6"MIN)OF RE/NFORGING,EXCEPT FOR SLABS ON hOL E5 A5 NEEDED 7HRU 5KYLl5HT FRAM/N5 TO MAINTAIN CONTIM)OU5 SELECTIONS IN ACCORDANCE W/774 MANUFACTURERS PUBLISHED A-I - PLOT PLAN MEGH. MECHANICAL S/M. 51M/LAR GRAS VENTILATION. SPECIFICATIONS. A-2 - REAR DE5K FOUNDATION FIR5T FLOOR CONSTRUCTION PLAN MFG. MANUFA6TbRER 5m SMALL 20. FIGURED DIMENSIONS SHALL GOVERN SMALL SCALE DRAW/NGS WHERE 26. SLAB ON GRADE SHALL BE POURED IN STRIPS. CON57RUGTlON OR CONTROL MIN. MINIMUM 5REG5 5PECIFIGATION5 D/MEN5/ON5 ARE E57ABL15HED BY COND/TION5. lF EX/5T/NG, E CH 1-1/5c. MISCELLANEOUS 5G? 521AREJO/NT5 5HALL HAVE A MAXIMUM 5PAGING OF 30'-0"IN EITHER DIRECTION. 17. DOMBLE J015 T5 CINDER ENTIRE BATHROOM AREA ONLE55 0R ERW/5E NO TED MMMILLIMETERGONTRAGTOR SHALL MEASI/RE EXISTING GOIdDIT/ONS PRIOR TO ORDERING SG? FT. 5QUARE FEET MAXIMUM AREA OF POUR SHALL BE 2700 5Q. FT. M.R. M0157VRE MATERIALS AND COMMENGINS W/TH WORK. 18. THE CONTRACTOR 5HALL INCORPORATE ALL REQUIRED 5TRRAP5 ANGLES RE515TANT 5.5., 5/5 STAINLESS STEEL 21 GENERAL CONTRACTOR AND H/5 5L/B5 ARE RE5PON5IBLE FOR ALL LAY- 27. ALL WALL AND PIER FOOTINGS 5HALL BE M/N/MUM 12" 774/GK AND PRO,EGT MTD MOUNTED 57D 57AVDARD TIE5, SUPPORT✓,ETC. A5 MAYBE REQUIRED FOR PROTECTION OF 57RU67URE Jyn• METAL 57Z. STEEL CUT WORK, INCLUDING SPECIFIED LAY-0UT DRAWINGS A5 REQU/RED. 6"M/N/MUM BEYOND ALL PAGES OF WALLS AND PIERS IINLE55 077lERlN/5E FROM FORGES OF NATURE. THIS INGLIIDES: ROOF r0 ROOF,•ROOF TO WALLS; N.I.G. NOT 1N CONTRACT 5TRUCT. 5TRX 7URE/-AL GENERAL GONIRAGTOR SHALL GOORD/NA7F RESPECTIVE SUBGON7RAGTGRS N07FIJ. WALL5 TO WALL5 AND WALL5 TO FOUNDATION. THE5E F45TENER5/TIE5 NOM. NOMINAL 5UPPL. 5UPPL Y/-/E9 50 A5 NOT TO GAU5E UNDUE HARDSHIP, DELAY AND INTERFERENCE WITH 28. GROUT 05ED SHALL BE NON-FERROUS NON-SHRINK GROUT BY IN-PAKT AND 5HALL BE A5 MFRV BY 5IMP50N OR APPROVED EQUAL. NOAUM. NUMBER 5USP. 5U5PENDEL7 CONDUCT OR WORK. SHALL ATTAIN A 577RENGTH OF 4000 N.SF. NATIONAL T/ TOP OF 22. CONTRACTOR TO REMOVE ALL DLBRl5 GREA7FD BY TH/S WORK FROM THE 175/ IN 7 DAYS. lq. ALL FA5TENER5 FOR FRE551RE TREATED LUMBER r0 BE HOT GALVANIZED. SAMTATION TB. THBOLT FOUNDATION TeB TOPP $ 517E AND D/5P05E OF IN A LEGAL MANNER ON A WEEKLY BA5/5 OR 2q. ALL SLAB TEMPERATURE REINFORCEMENT r0 BE FIBERMESH CONCRETE BOTTOM N,T5. NOT TO SCALE 7e5 TONGUE $ GROOVE SOONER 1E,GOND/TIONS hG4RRANT. REINFORCEMENT A5 MANUFACTURED BY FIBERMESH CO. OR APPROVED ?91 OA. OVER ALL TEMP. TEMPERED EQUAL. MIX/NG AND PLACEMENT SHALL BE IN ACCORDANCE TO O.G. ON CENTER 23. AT THE COMPLETION OF WORK, THE 51 TE I5 TO BE CLEARED OF ALL O.C. OPEN/745 U� lT Rl7FR5DEBR/5ANDEXGE55MATERIALS THE FACIL17Y l5 TO BE LEFT BROOM MAAVFAG7URER5 SPECIFICATIONS OPT. OPTIONAL LABOR4TOR/E5 GLEANED AND WORK 15 TO BE COMPLETED TO THE TOTAL 5AT/5FAGTIoN J OPP. OPT'0517E W. UL TPA VIOLET OF THE OWNER PRIOR TO RELEASE OF FINAL PAYMENT. 51FEL BUILDING D PI' PL. PLATE V. VOLT/VOLTAGE 24. THE ARCHITECT HA5 NOT BEEN RETAINED FOR ADMIN15TRATION OF 774E I. ALL STEEL FADRR16ATION AND ERECTION 5HALL CONFORM TO A15G rDWy Or SG:JTHOLD PLM5 PLUMBING VB. VAPOR BARRIER 6ON5TR06TION OF THIS PROJECT. 5PECIFIGAT/ON5 FOR 5TRUCTURAL 5TEEL,LATEST EDITION. PNL. PLYWOOD V.P. VENT PIPE 25 GON7RAGTOR5 SHALL COOPERA7E WITH ALL OTHER TRADE5 AND WHERE REVISIONS/SUBMISSIONS: DRAWING TITLE: P1VL. PANEL VERT. VERTICAL 2. ALL STRUCTURAL STEEL SHALL BE A5TM A 36 EXCEPT STRUCTURAL TUBE SEAL:,.~' ;.. PR. PAIR rv/�,r/o W/77yAVlTHOU7 RE60RE9 INSTALL ALL BU/LT-IN WORK SLEEVES IN5ERT5 ETC. AS r�{'-fes PREP. PREPARATION/PREPARATION/ WDOD REQUIRED FOR A COMPLETE JOB. WH/GH SHALL BE A51M A500 GRADE B. AND S7Rl/G77/RAL PIPE WH/GH SHALL f -;,�f✓:' ,� DATE: DESCRIPTION: PREPAY BE ASTM A50/. ,;.,,, ��� 6/19/2022 J//UCD FOR PERMIT GENERAL/10TH/•, LEGE. P f, , t• ADW. A/IVDOW 26. 5EE N.Y.5. BUILDING CON5TRZTION CODE MANUAL FOR REQUIRED WOOD P.S.F. POUNDS PER DRAWING L/T AND AF55REVIATI0N,/ SQUARE FOOT N.H. WATER HEATER FRAME NAILING SCHEDULEE, 3. ALL 577RI MRRAL 57EEL USED A5 EXTERIOR WALL LINTELS SHALL BE P.S.I. POUNDS PER `hp AA V7I7ER PROOF GALVANIZED. fir, SQUARE INCH PT PART/POINT Ah!FR� HIRE CAD FILE NAME: FAB PVMT PAVEMENT NEMSCHICK SILVERMAN ARCHITECTS P.C. PROJECT TITLE: DATE: NSA PROJECT #: the business of ARCHITECTURE." fOUTHOLD RUIDEACE 4/11/2022 21-2513 - _ - ---_ _ _ ... ------ - AIN P�AYVIEW RD. /OUTI1OLD, NY 11971 DRAWING /71 66 EAST MAIN STREET - _......_..--- __.....__ _ .._... _..... ..........._..- ------------ ---------- _...... ........ ..... ---------......_._ _--- -----::�, - ED PATCHOGUE, NEW YORK 11772 DISTRICT: SECTION: BLOCK: LOT: DRAWN BY: cy- Phone : 631 563 2130 Fax : 631 563 2139 WWW.nsarchitects.com (C)COPYRIGHT 2022 NEM"CK MVERMAN AR04MCTS P.C. 1000 88 5 26 JTM CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA OF THE TOWN OF SOUTHOLD PER 2020 RESIDENTIAL CODE OF NEW YORK STATE TABLE 8301.2 (I) SITE AND ZONING DATA WIND DESIGN SUBJECT TO DAMAGE FROM GROUND SEISMIC WIND ICE BARRIERAIR MEAN a FLOOD ZONING REQUIREMENTS REQUIRI=D EXISTINGPROP051=D SNOW SPEE=D TOPOGRAPHIC SPECIAL WIND WIND-BORNE DE51GN ' FRO5T LINE DESIGN UNDERLAYMEN FREEZING ANNUAL LOAD (MPH) EFFECT5k REGION' DEBRIS ZONE" CATEGORY WEATHERING DEPTHb TERMITE TEMP REQUIRED" HAZARDS INDEX' TEMP 800' LOT AREA MAX 40)000 S.F. 17,248 SF NO CHANGE LERATE TO PRIMARY FRONT YARD SETBACK 35.0 FT. 3'1.1 FT. NO CHANGE 25 P5F 128 MPH SEE PANS SEE PLANS SEE PLANS B SEVERE 3 FT. MODSEE PLANS SEE PLANS 5� PLAN SEE PLANS SEE PLANS � EXAMINER EXAMINER EXAMINER HEAVY EXAMINER EXAMINER EXAMINER EXAMINER EXAMINER SECONDARY FRONT YARD SETBACK 20.0 FT. 34.1 FT. NO CHANGE MIN.SIDE YARD SETBACK 10.0 FT. 35.0 FT. NO CHANGE TABLE 602.50) FA5TENIN6 SGHEDULE \ REAR YARD SETBACK 58.8 FT. 10.8 FT. $8.8 FT ITEM DESCRIPTION OF NUMBER AND TYPE 5PAGIN6 AND MAXIMUM HEIGHT 35.0 FT. 35.0 FT. NO CHANGE BUILDING ELEMENTS OF FASTENER LOCATION FLOOR 9,60' MAX.LOT COVERAGE 20% II.bSK 14.9go (2 Y2" x 0.113")• or 4-8d box \ �,_NOTI=_, EXISTINC-s LOT IS NON-CONFORMING, SETBACKS AS PER 280-124• 3-8d common 21 JOIST TO SILL, TOP PLATE OR (2 YY x 0.13 1")• or TOE NAIL 3-10d box GIRDER (3" x 0.128"); or , 3-3 x 0.131' nails AREA CALCULATIONS 8d box 2 " x 0.113" • 4" TOE EXISTING FIRST FLOOR 1,165 S.F. 8d common NAIL EXISTING SECOND FLOOR 846 S.F. RIM JOIST, BAND JOIST' OR (2 " x 0.131")• or O 22 BLOCKING TO SILL OR TOP 10d box 6" TOE .(� +V�' EXISTING DECK 234 S.F. PLATE (ROOF APPLICATIONS (3" x 0.128"); or NAIL �q-7, NEW DECK 5-12 S.F. ALSO) 3-3 x 0.131 nails a 3-8d box (2N' x 0.1139• or 2-8d common m (2 Y2" x 0.131")• or `QRe 20� 23 I X 6 5UBFLOOR OR L•E55 TO FACE NAIL EACH JOIST 3-IOd box (3" x 0.128"); or 1.4� 2 staples, I ' crown 169 ea., 1 3/4" Ion 3-I6d box 24 2" 5UBFLOOR TO J015T- OR GIRDER (3,142" x 0.135"9• or BLIND AND 2-I6d common (3Y2" x 0.162"9 FACE NAIL xJs1'j 3-I6d box AT EAGH 25 (3 Y2" x 0.135"); or BEARING, Is, Sj1UGLF G12,IS 2 PLANKS (PLANK BEAM- j t A� FLOOR 4 FLOOR) 2-I6d common D� C (3 Y2" x 0.162") FACE NAIL 3-I6d common (3 Y2" x 0.162") jN 4-IOd box 26 BAND OR RIM JOIST TO JOIST (5" x 0.128"9; or shy„ x O. nails END NAIL 4-3 x 14 ga. staples, crown 20d common NAIL EAGH (4" x O.IQ29; or A5 FOLLOWS: 32" O.G. AT TOP AND BOTTOM AND n` 5TAC6ERED �,r IOd box 2 O.G.FAGE NAIL AT 44 (3" x 0.128"); or TOP AND BOTTOM 3 x 0.151" nails 5TA66EREI)ON (}� 27 BUILT-UP GIRDERS AND BEAMS, 2 OPP051TE 510B INGH LUMBER LAYERS 2nO 20d common �v (4 x O.IcI2 ); or FAGS NAIL AT rl 3-I0d box � EENDS AGH SNPLDIG T � � /l � (3 x 0.12b'9; or Ck TQ �cj� 3-3" x 0.131" nails 4-I6d box ry (5,6" x 0.135")• or 3-I6d common AT EAGH 28 OR RAFFTERSIP SUPPORTING J015T5 (3Y2" x 0.162") JOIST OR 4-I0d box RAFTER FAGE (3" x 0.128"); or NAIL -3 x 0.13 nails 2-IOd box (3" x 0.126);or EAGH END 2G BRIDGING TO JOIST 2-8d common (2 �" x 0.131" TOE NAIL ITEM DESCRIPTION OF NUMBER AND TYPE 5PAGIN6 OF FASTENERS INTERMEDIA BUILDING ELEMENTS OF FASTENER EDGES (IN.) TE SUPPORTS (IN) ALLOWABLE DEFLECTION OF STRUCTURAL MEMBER5 MINIMUM UNIFORMLY 015TRIBUTED LIVE LOADS PER 2020 RE51DENTIAL CODE OF NE=W YORK STATE TABLE 8301.1 PER 2020 RE=SIDENTIAL CODE OF NEW YORK STATE TABLE 83015 �cp ap �Sfj STRUCTURAL MEMBER ALLOWABLE USE LIVE LOAD ^� 1(6 L = 5PAN LENGTH, H = 5PAN HEIGHT DEFLECTION ry�D RAFTERS HAVING SLOPES GREATER THAN UNINHABITABLE A7I05 W/0 5TORAGE 10 P5F t� 3:12 WITH FINISHED CEILING NOT ATTACHED L/180 TO RAFTERS UNINHABITABLE ATTICS WITH STORAGE 20 PF INTERIOR WALLS AND PARTITIONS H/180 HABITABLE ATTICS AND ATTICS NV FIXED STAIR 30 P5F FLOORS L1V60 BALCONIES (EXTERIOR) AND DECKS 40 P5F GEILIN65 WITH BRITTLE FIN15HE5 GUARDS AND HANDRAIL5 200 P517 (INCLUDING PLA5TER AND 5TUGC0) L/E60 \ GUARD IN-FILL COMPONENTS 50 P5F GEILIN(55 WITH FLEXIBLE FINISHES (INCLUDING GYP5UM BOARD) �`� ROOMS OTHER THAN SLEEPING 40 P5F �68w0 ALL OTHER STRUCTURAL MEMBER5 L/240 SLEEPING ROOMS 30 P5F ��O%Y EXTERIOR WALL5- WIND LOAD5 WITH L/360 STAIRS 40 P5F PLASTER OR STUCCO FIN15H EXTERIOR WALLS- WIND LOADS WITH L/240 OTHER BRITTLE FIN15HE5 EXTERIOR WALL5- WIND LOADS) WITH L/120 FLEXIBLE FIN15HE5 ALL OTHER STRUCTURAL MEMBERS L/600 /// 0\ gr'\ rp rp SEAL: REVISIONS/SUBMISSIONS: DRAWING TITLE: DATE: DESCRIPTION: 6/13/2022 IfAm FOR PERMIT PLOT PLA/1 & rN ',, ti=' ,;c,\, ZONING ANALYYV ^k, ;6ALE: l" l0' +! CAD FILE NAME: n 2515A PROJECT `fITLi '` DATE: NSA PROJECT #: I�EMSCHICK SILVERMAN ARCHITECTS P.C. ,�'OUTI�OLD RF�'IDF_/`IC�. ". ..the business of ARCHITECTURE." 4/11/2022 21-251-5 HC:) — — _ _ - -- -- DI __-- -- AYVIEW R ._. CALE: DRAWING •./'OUTt�OLD, NY 11971 •• 66 EAST MAIN STREET _.__..........._.....__..._.__....-.. ---�._..__...._ - __ -- ------- _ _ ----_..---- -_. - _...___. J NOTED PATCHOGUE, NEW YORK 11772 DISTRICT: SECTION: BLOCK: LOT: DRAWN BY: A1 ..,.. Phone : 631 563 2130 Fax : 631 563 2139 wwwnsarchitects.com (C)COPYRIGHT 2022 NEMSCHCK SLVERMAN ARCHTECTS RC 1000 88 5 26 STM 42-5" 3 ' l6"O X36"DEEP MIN. F,5. FTG. WITH(4)3# 16 NO X 36"DEEP MIN. RAILING TO ATER RIBAR VERTICAL OYP) N � P.G. FTG. WITH(4)3# q AT 4""O.C.O.C. O-M) I, ti LAEGK ti REBAR VERTICAL (IYP) " ry ABOVE N cp N N ry " k p NEX ZNEN DECKING DN 4 N DEGK A5 SELECTED MAX l5 R N P.T. 2X6 D.J. BY OWNER �d T. 2X6 D.J. � P.T. 2X6 D.J. N �� ] MIN. O" P.T 2X6 D.J. 0 l6"0.c. P.T. 2X6 D.J. 0 l6 O.G. �G ® 16"O.G. ® 16"O.G. I2"DEEP P.G. HAUNCH 20"0 P.G. FTG. WITH(4) CONGEALED FLANGE BEAM HANGER. AT BOTTOM STEP 3#REBAR VERTICAL. FACE MOUNT BEAM (TYP ALL BEAM TO HANGER FLEDOER CONNECTIONS) 2X12 P.T. LEDGER m IL U4 EXISTING FOUNDATION m -1 N 'IN VENT TO REMAIN \--mw RAILING TO 36" NEW DECKING UNOBSTRUCTED (TYP) H/GH WITH BALU57ER5 A5 SELECTED N EX/ST/NG AT 4"O.G. (TYP) = BY OWNER ZZ ,Z ABOVE TO BE REPAIRED 16 NO X 36"DEEP MIN. P.G. FTG. WITH(4).3# RcBAR VERTICAL M ) - 7'11„ Q: 20 O P.G. FTG. NITH(4) 3#REBAR VERTICAL. �X/ST/NG N N ~ 12EGK 4 Try X TO BE REPAIRED P.T. 2X6 D.J. N ® l6"O.G. O P.T. 2X6 D.J. �o 0 l6"O.G. 16 NO X 36"DEEP MIN. P.G. FTG. WITH(4)3# DN 4 REBAR VERTICAL. MAX RISER 8" MIN. TREAD /O" 4 ' l2"DEEP P.G. 6 0 6-�� HAUNCH AT BOTTOM STEP R LZEC K 1=01/\1,12A TION COl 5 TRUC TION A N RP7AR LFIR5T �1-00R CON5TRZT/oN SCALE: 1/4"= P--O" ALE : 1/4" _ P-0" 36" HIGH RAILING 5Y5TEM PER 2015 IRG 36" H16H RAILIN6 R312.1 A5 5ELEGTED BY 5Y5TEM PER 2015 IRG 2X RIM OWNER R312.1 A5 SELEGTED BY J0I5T5-5EE OWNER EXTERIOR 5IDIN6 PLANS 1/4" LAG 36" H16H RAILIN6 5Y5TEM BOLTS PER 2015 IRG R312.1 A5 THROUGH PROVIDE SELECTED BY OWNER J015T 4 LANGHORAC7E CONNECTION 51MP50N DTT2Z PROVIDE SOLID FOR P05T AT J-GHANNEL DRIP ED6E AT P05T CONNECTOR BLOGKIN6 IN FIRST TWO EXTERIOR WALL 5I0IN6 BASE BAYS OF DECK JOISTS PVIDEFOST GONNEGTI ON FOST GONNEGTI ON 36" H16H RAILING 5Y5TEM PER BEND J METAL AT TOP FERE I ND I GULAR TO JO 1 STS PARALLEL TO JO 1 STS 2020 IRG R312.1 A5 SELEGTED OF LED6ER BOARD BY OWNER DEGKIN6 A5 SELEGTED BY 2X RIM J015T5 (5EE PLANS) OWNER. DEGK GIRDER (5EE PLANS) 2X8 MIN. P.T. LEDGER • 51MP50N DTT2Z HOLD DOWN TO BOARD ATTACHED TO 36" H16H RAILING 5Y5TEMLEDGER THRU-BOLTED TO RIM PER 2015 IRG 8312.1 A5 SIMPSON TS-9 FOUNDATION RIM J015T TW15T STRAP W/ 1/2" LA6 BOLTS ® 1611 J015T5. MUST BE PROVIDED AT SELEGTED BY OWNER 4X4 MIN P.T. P05T TO GONG. 4X4 MIN P.T. P05T TO GONG. O.G. 5TA66ERED GORNERS AND A MAXIMUM OF FOOTING 6'-0" O.G. ON DECK, WITH A MIN. FOOTING 51MP50N PB-44 P05T BASE OF 4 HOLDDOWNS 51MP50N PB-44 P05T BASE a , WITH A MIN. 6" EMBEDMENT WITH A MIN. 6" EMBEDMENT INTO FOUNDATION PROVIDE SIMPSON HU PROVIDE P.T. 2X SOLID •• INTO FOUNDATION POURED CONCRETEA. GALVANIZED J015T HANGERS AT BLOCKIN6 AT STAIR R15ER, •' FOOTING d ' LEDGER BOARD 12 DIA. X 36 MIN. DEPTH • 36 MIN. DEPTH POURED GONG. 6AP CANNOT EXCEED 3 POURED GONG. FOOTING - FOOTING - (5EE FOUNDATION POURED GONG. FOOTING O° P.T. STAIR STRINGER (5EE FOUNDATION PLAN FOR PLAN FOR DETAILS) - 5EE FOUNDATION PLAN WT P.T. 5TAIR 5TRIN6ER DETAIL5) DETAIL GOMPLIES WITH FIGURE 12" POURED CONCRETE 8507.2.3(2) NYS RES. CODE HAUNCH AT BASE OF 5TAIR DECX POST ]DEGK FRAMING DETAIL DECX GONNEGTI ON DEGK STAIRS FRONT V I EVS AT END CONNECTION TO RES I DENGE SEAL: REVISIONS/SUBMISSIONS: DRAWING TITLE: DATE: DESCRPTION: ✓-\J`1 >Qom;'. 6/13/2022 YIULP rOR PERMIT REAR DECK / — ��\� FOUNDATION & FIRJT FLOOR LCNg IwRA IY �6 7 7A / c _ ;�� CONJTRUCTION PLAN SCALE: 1/2" _ P-O" a. CAD FILE NAME: 2513 A-1 NEMSCHICK SILVERMAN ARCHITECTS P.C. PROJECT TITLE: DATE: NSA PROJECT «: ". ..the business of ARCHITECTURE." JOUTHOLD RUIDENCE 2022 21-2515 11b10 MAIN P)AYVIEW RD. ..... ..._.....-.. _.._._........._._...._......_ ......... ...__........._..... ............_........ .........- _.. SCALE: DRAWING NO.: ,./'OUTI�OLD, NY 11971 66 EAST MAIN STREET - - --— — f NOTED PATCHOGUE, NEW YORK 11772 DISTRICT: SECTION: BLOCK: LOT: DRAWN BY: A-2 Phone : 631 563 2130 Fax : 631 563 2139 www.nsarchitects.com (C)COPYfdGHT 2022 NEMSCIiICK SILVERMAN ARCHITECTS P.C. 1000 88 5 26 STM