HomeMy WebLinkAbout46883-Z �o��g�fFDL,�coGy Town of Southold 4/8/2022 P.O.Box 1179 c _ 53095 Main Rd �aojNi Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42975 Date: 4/8/2022 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 250 Seventh St.,Laurel SCTM#: 473889 Sec/Block/Lot: 126.-1-7.8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/16/2021 pursuant to which Building Permit No. 46883 dated 9/27/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"finished basement(recreation room and bathroom)to existing single-family dwelling as applied for. The certificate is issued to Carr,Ryan&Michele of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46883 1/27/2022 PLUMBERS CERTIFICATION DATED 10/22/2021 Jo h INis& So Inc. A h iz ignature oufF�'�eco TOWN OF SOUTHOLD �S BUILDING DEPARTMENT H x TOWN CLERK'S OFFICE SOUTHOLD, NY 0 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46883 Date: 9/27/2021 Permission is hereby granted to: Carr, Ryan 811 Roanoke Ave Riverhead, NY 11901 To: legalize "as built" finished basement to existing single-family dwelling as applied for. Additional certification will be required. At premises located at: 250 Seventh St., Laurel SCTM # 473889 Sec/Block/Lot# 126.-1-7.8 Pursuant to application dated 9/16/2021 and approved by the Building Inspector. To expire on 3/29/2023. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $916.00 CO-ALTERATION TO DWELLING $50.00 Total: $966.00 Builds ector pF SOUjyQI 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 aQ sean.devlin(aD-town.southold.ny.us Southold,NY 11971-0959 Q COUNTI,'� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Ryan Carr Address: 250 Seventh St city:Laurel st: NY zip: 11948 Building Permit#: 46883 Section: 126 Block: 1 Lot: 7.8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 5 Ceiling Fixtures 2 Bath Exhaust Fan 1 Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 1 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 14 CO2 Detectors Sub Panel X A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 11 4'LED Exit Fixtures Pump Other Equipment: 16' Electric Baseboard Heat , Sub panel 8 Circuit/ 5 Used Notes: " AS BUILT NO VISUAL DEFECTS " Finished Basement Inspector Signature: Date: January 27, 2022 S.Devlin-Cert Electrical Compliance Form Oil' -, it r" H.ri>+' `�✓-«-s, >„ , "`'4,''^e w ", '° ' z "r,. #� a. r a is '�'+ '°,z,; .W'� ";�>. f Vis` a « ml's >z �»y��' �-� ra.:, 'arm;er & . cam � ,a..� y�.r,�,. ,�,.��'g� ��,�.$'."amu � r .,•� ����� �"'� ,� 1��a'�� q r X�'.t��r-?"'"",�,"�' �,�*�x�" �' ,Y� €z? > �• ys , , St z> tr , z« y z. ,r .�# ` Y` S a € �° .3 �•}°z'..'a� x,, ,�� xSh „�_.. <,`z'' r� x` �€ v.�d"' �.�'-+°r�e•�� :z+x `,t5`y�, `� �i�s d`.�";��y3�- ''��'`� €yn� w.+,�.�' ?? =3- ,S""~�a` �`�.3�:rz h7�„,�,>�,s�T a, � � ��d'�f'��k:.' N . �_ <., � ,r ',,< dr '' s .. < , a ,^? ✓ ' z 's' �'^+'«'s �g3,iSF. b� ,. tk �..4•z�.rc`"' " 'G�g�ee;��-s^a r•r'„ ;.'"`� ..zp a S�C.r `'� 5 -'?. �naa+ `.` h 2F` � m ,, «",�?� F ���• 33 � :,,�r d� �� •n .�uh�'"°°�;*� g«,� �s ��F �k"x�., �, C� ".�'�*"r„' a :`�^ � fir.,r r '" � rzr>`: a y� ,� �� `'� F1: rr��:# ,�, �..�� � '�°� a� � �°x'���•�. � � ,� >'�z'��e�z,yx �F,' '`^tty�,� �"'�' +a'.rcE F., �`�� '"x %a»? ..g z a''a a�' E'-„•;'�, a;v:y���� "z?, r e;�.,z rw;,.w�.�d e< :'! �� r `r.�>'� , tU` ?p £ _ n. ':o- x ,>$'`r, &cR ^„mus 3, .4e �k fry >s, 'r�$f a ,. "« �� ., wm �� " a - , ' ' ,y, s�.` < My k' -.af ,,, ;T,'�; •`,,�i,,e: s�<,»'w.rr, a�,' �y� ,a•.a A... 's . �"w .,r5 ry'� e;s w•�z`a=,. .^�- ";"», s = Ps y"'''N. �211",, �g.E.... ,:�s,.:z -,„.,"!r t '�3 z"�"�t. ,�'•a ark . ',8s ,`� 3> .,za#y'k x >;c��"rC i •; 't< rza „`°. ,.a ,'1..Prz -.,,"frd" zf' ,r�sx�,r.3.,'' r .,•'.'3 r�'z"" �+ c�r " ':g �' "�` ;x-.. 'p >» :�.;�k wk r ';ank s f° a'¢°.a^ate,,', r�^a E r, y z' '4 5r�'5r a V,r 3 '�3 s e a a ? a `&' v o-a » ,?<,.' '` <s,• °r1 ',,, wa, �" san �,��.,ssir`a`` y '. 3 ,. s.;. ^' •�„..:, a'k, zr.* '� >,�•; '. :°a�« r ''an k'`" ��x�'; "k # � �..n� ��n a,°` nx >, " dc>. >" !i ,,,z ' - € -�v .' {� , rYs x. ,, rt n,. "' F� : '�' 9'�n'.,• S ,� ' ' ,� ,,. & ' �... ' r+� .u0%t' ;,. +� air �sev�l�i fF f.✓M Q <f� r' „ ..� 33 x�,„� �s 4`. ���� '. <a�"�«;e< »�^' ry��xz :rz., >,»u. �� P 'i�r' _ •zs.” � a„s'w�, -..€:rfi� s ;„ ,-,c r,- � '`` �:�:;.'a.•��., `a a'� r' �`�.��' t^ „�z ,��:. P �'••n�, , � �,�,"�{apse� : w , ° §,� '.,,z•,. z s ,q,.:�' � ,9r,.yq �x, �>��^'�`akS;�z" .,zr..•�,,, a .0 t�" <�, � � �'r L� ��w:. � a• r� `�'{. •:�., �t t .d rowz'" � »'r*° ur s z, :' s�c„r ^YScv�r.- aQzT ,,"fir >;�-Cn.e a.-s, :, , !r � '`d•'', "e� ''�., �' a <t,k+«� 1� � " •r ', ,ftk':' wow �k,q ae1"u'; - �nWy^� '�,;; +� ,t 0511 V21 tt+ a, -5 `�`,. s" °Ce: .s_ "scs.-„��-,Az,, •s'?' art °2':z a t ;.:z i x .` m /'.�+M,' y ,,,, ,% _ � ,^ ' s k° a. '{:a �•3 n '.r"`� R rs. fit. k�� �'-:, •a�• �„�' fir”' � .� .z, '� ���Pi.•.c C.�Y �a `r,^�"f� �a y" �A, `��":'� z°`•.t;y4C` `��'�-« err.:,; �'�.`��:, '; aZ ,;. P � s �� .: -F.nr � �,i�� i r.>;® osr :3 <�+'s� s � `' 3y�'�n,.. ,� <�,kir ,.t�>, :;a" ,,: �.•<, ,.frsmt '2„„t,�,,€ a ..;a t ". F -" :+, .•r'zr > >�v,.r 'td,e N.Y•'"*:: y � .,... M NR{',�,' -.afiy-- "n "a^, r "'�"Ytl ." r3" z„ '"u n 'r> 3 •*�, ," s :'4 �cek#,c# �'` n a,, A•rz',, 7r ,x,a , E' ""'a y `'x,`-^t rtlaa. 5, 3'rs e.,-S +, •'Z^ '3 rtn" ,a> ,.: :ter .•r�m�r,?r a �.�;,:F k «zy� r ., .P,�`,•' ;, ,�a j / p, �,�rr. a;>y�n>, .: <, -`�r,..a:w ,a• .� `,. .., ..�,a. '' 3,K: :. -c 0'ia'..;.' �. `�G`6TZ a;:.z +"�, $� .s�. a�xs (� 's'srivolztx € . 'sr't z 2 �u,. > a •sa�. 'a ,vc7� e 2" y, sa ,x'm>• .r ,..r�rx m:;y � , °z n 'a ^` ', ": ,s UA-RA... r; a«Sta z a„ d,C • '�" '-r`� :a `:- �,,"�,,,�• €'rt'f's�;�,. Pa�6'.'aa--:.:'S�+'�';"c*�tJg»�a+�.�:'-:-.«ar-x `,v^a�•-."��:.s.�"�a�z�¢D,,�.4.�t^:, �>��,p>;c,-r,f,�i�, Y 'd r ,e4"m� ��.,.> .?,z„,�:'an � ;lc«.. r�+ -m 2.a ., 'try? , �,.a;;, ' ,v„c ,N �,%`•�, .«,+;.s zi '` >` 1 .„. �• `�,��°,g:*' �;:� �'.. m '�'s. �� ����+�” "�` W1, � r .:x �'"` r f '” :Ste; �Y.. e€,3- -±• ,+ >. v;$ ;T, n«"'` r,,,• s '+x.-4 ! 3 "r a �-e»:�`"'. kv .s.-L ,�.$�. ..r• 7h£..•f-.Y` z ,," '"`, kaa .: - ztK a; ��;a•t �`'; >g» 4�,��> t��� �.3 ��Yyc"��'>`�.� 4;,,w :,��" ',,� `✓, y:o,cy o,.- O `9,ry ;�,�'$ , :.'y4 ,' ram9 r.; .» ,+. A'R ,.�'-s'rs" 'a $yz,>.sw , ''y-r a',° cq 7 41 §� y � p '" ,r `> �, `, :..ro - a Vr,.. 3 1.I s .n 'n, ° 9� cs { i^� � s€'.. � ', ,•,a- ,€ c.a «„�, `3':����.' �w� anima-,` �Ex°_ � crt �, ��., ��a?� 4� �,s far( a a• :fir �•, s �r y�! a �� �.a '`:� �' �a f fir�� zt � �'' � � rH .rk >-°& �ac �•d� .,j �^F,x 4,, -�'�v •v r.�, £,�?r'''r'E��a �,,��.r�„ �> � , r „, aE� � .,�>-.'», �`yaa '�� .Pott 1 r�Z� E ✓, s' r: a r, '4 .,,,�i ,, z a.?.'� �.� ..,. szr :6�, «. ,.:�, x�. ”,+z�,' ia'c a, ,;z: -�. ° � u• -.r ^> ,} ,r .,2n.. m ,. P"3�' , ,, ["i-a ,r b - w r,.� =a� S� '^ �C� `i�;x.:: y,�`ea « ��,a,,.. '�xr.,z� d >,..>.,�P. €�"s'.M -.3.�c....�:a :'-.s�,•3a;r <, �`„lm Eta `�` �a� ".."� � �ha,'°���� « a.;a `""�y �,:.• :a z +�1p{ `�� xf� sk>s�:�:a'° s.;: °'� ,.1.9�. �nr ..N�ry� "a,a,,gs, �.r ,,,,�'��,.. _�'€�%” n ,., � _. ". •�-�'', �:"� ,wa>�iy}�Kv. �v� °^�,-�z�� �yF- .j, � "3 �;3� P; a�, 'cr r�>arS;;t r t '.� � -,a+, �..%;9 « .� .', � � .' ,�mr ry #�'. �r�� „`•,a ar��y >{.;a a�'"�x � �.,�>�''�5 SOUTyOIo * # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm, 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION-2ND [ ] NSULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL (AAj 6 V (t4 [ ] FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL.(ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ PRE C/O REMARKS: 1 �'X TP(v %lplf" Sol DATE INSPECTOR r^ g3 of SOUI - # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ NSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL V.— I qsve [ ] FIREPLACE & CHIMNEY [" ] FIRE:SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O MS REMARKS: f V Tb L 0 !y u C 2`F DATE '7.o z2- INSPECTOR 1 SOUIy�� # # TOWN OF SOUTHOLD BUILDING DEPT. `y�ourm a 765-1802 INSPECTION [ ]- FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /.STRAPPING [ ] FINAL { ] FIREPLACE &CHIMNEY [ ' ] FIRE SAFETY INSPECTION [` ] 'FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: ez— DATE l INSPECTOR r}M 4 1 - - g ;r } P:. 4 1 y < ry.Wu 'Air- A M W. f� cs FR .4. �N �.n ri lW �. Q � i Operating Business Address:1075 Franklinville Rd,Laurel NY 11948 -A RCHfrECTURE Brooklyn Office:450 95th St,C9,Brooklyn,NY 11209 Laurel Office:1075 Franklinville Rd,Laurel NY 11948 f Business Phone:(516)214-0160 Anthony Portillo:(716)572-4741 February 17, 2022 FFR 1 7 2G22 BUILDING DEPT. Southold Town Building Department TOWN OFSOUTHOLD P.O. Box 1179 Southold NY 11971 RE: Carr Residence 2507 th Ave Laurel NY 11948 To Whom It May Concern, Based on my inspection at the above address,the rough plumbing and insulation in the basement were all installed per NYS Building Code. Please contact our office if you have any questions. Thank you, Anthony Portill , R.A. .Ct,H. P0 ®.7°tti 4l1 0374( .d 9TF4F N�'�� SYS TEM i4 Series s TM Combination CO/Photoelectric Smoke Detector Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i°Series combines CO and smoke detection • Single device for CO and smoke detection that uses less wiring into one device,requiring less wiring and fewer back boxes than and fewer junction boxes two separate devices.The i'Series is compatible with P(2WTA-B or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing P installations.The i"Series CO cell can be required i"Interface Module. easily replaced at end-of-life,resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i"Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs display both CO and smoke status Installers can pre-wire its plug-in base,while its large wire-entry port • External IR LED provides extended range sensitivity testing and in-line terminals provide ample room for neatly routing wiring.The base accommodates several back box options and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i°head plugs into the base with a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N LockTM action.When the detector's CO cell reaches end- timer that signals the panel and chirps to alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i"Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station. Intelligent features,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms,reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i^Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. Rv LISTED 5266 1BE3,0227 Carbon monoxide(CO)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wire)listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box,The detector shall be capable of automatically adjusting its sensitivityby means of drift compensation and smoothing algorithms.The detector's base shall be able to mount to a single-gang electrical box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance,CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Operating Voltage(VDC): Nominal:12/24;Minimum:8.5;Maximum:35 ,Maximum Standby Current: 50 pA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 185 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 pF Dimension: Diameter:5.5;Depth:2.5-(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 20-95%RH Storage Temperature Range: -10—70°C(14—158'F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes:3.5-and 4-Octagonal;Single-gang;4-Square;2 x 4-,,3.5-and 4-round ceiling. Direct mount to wall or ceiling. Alarm Smoke: Off On Off Temp 3 Alarm,CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTese Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series Interface x A k, and Reversing � f Relay Module a F i The P Interface Module connects up to 12 detectors to a ` Q . wide range of control panels using only 2 to 3 zones. It also interconnects the devices, so when one device alarms, they all sound. Features Integration:The i^module allows up to 12 i4 Series or compatible • Easily integrates up to 12 compatible detectors to a wide range of i3 Series smoke detector models to be integrated into a fire alarm control panels panel using only 2 to 3 zones:a smoke zone,a CO zone and an optional trouble zone. Detectors sound Temp 3 for smoke and Temp • 2-wire module is compatible with COSMO-2W combination 4 for CO events.The i°module can be used to alarm all sounders in detectors and 2WTA-B smoke detectors. compatible detectors for smoke and CO events.When one detector • 4-wire module is compatible with COSMO-4W combination detects smoke or CO and goes into alarm,all connected detectors detectors and 4WTA-B smoke detectors. alarm,offering the highest level of warning to the homeowner. • Sends distinct smoke and CO signals from i4 detectors to the panel Installation ease:The i4 Series Interface Module mounts to a • LED indication shows when a detector on the loop requires 411/16-inch square back box for quick and easy installation.Terminal cleaning or maintenance(2-wire detectors only) blocks with durable SEMS screws ensure a reliable connection.It • Initiates the EZ Walk loop test(2-wire detectors only) also has pre-drilled holes for easy mounting inside a metal enclosure • Module interconnects the sounders of all devices connected to it. Intelligence:The i4 Interface Module allows i4 and compatible i3 No RSS-MOD is required.Optional trigger inputs are provided to sound multiple modules. smoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i4 Interface Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings 0 LISTED E911 1653:0228 i4 Seri nes Interface Module Specifications' The i°module shall be a System Sensor i°Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws.The module shall provide 4 LED indicators that blink or illuminate to indicate communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The module shall allow communication to i"Series and i3 Series detectors with sounders with any UL 864-and UL 985-listed fire alarm control panel capable of utilizing this module.The 2-wire module shall offer provisions for Style D/Class A wiring on IDC loops and shall provide a loop testing capability(EZ Walk)to verify the initiating loop wiring. ModuleElectrical Specificationse Operating Voltage(VDC): Nom.:12/24;Min.:8.5(2-wire),10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:61m(max.),45mA(12V In),26mA(24V In); 4-Wire:52mA1(max.),37mA1(12V In),22mA1(24V In) Alarm Currentz: 2-Wire:181mA(max.),121mA(12V In),64mA(24V In); 4-Wire:78mA1(max.),57mA1(12V In),34mA1(24V In) Maximum Ripple Voltage: 30%of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA®36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage:1.5V;Max.:Vin 1 Does not include current draw from attached detectors or EOL relay.2 Does not include reverse polarity current draw from attached detectors. Physical Specifications Module Dimension: Height:6.04;Width:6.04--,Depth:1.00- Weight: 9.6 oz.272(g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20—70°C(-4—158°F) Input Terminals: 14 to 22 AWG Mounting: 411/16"square back box or inside a metal enclosure Operation Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke&CO: Blink 1 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode(2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance(2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble(i3 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Module Power-Up Sequence/LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information Part No. Description COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-41N models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-41N models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with-4-wire systems) ``� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013System sen Phone:800 SENSOR2•Fax:630-377-6495 P'oduc:specifi:ations s-bject to chance wth=ul notice.Visit sys:sms=nsmco- �``� .SEA/SORw 'cr current product nto—aticn.Incl-ding the latest verion-'this-ata sheet. �y �\/ www.systemsensor.com COD330302•11113 rE ff� ., Smoke Detectors with Sounder and Relay Option £ 'iql Y9 System Sensor i3 sounder and relay smoke detectors � � � apply the guiding principles of installation ease, 3 intelligence,and instant inspection in a series of M specialty conventional devices. Features Installation ease.Throughout the i3 series,installation is simple 85 dB sounder with its installer-friendly base and plug-in design.The base accommodates a broad range of back box and direct mounting Form C relay options and provides ample space for pre-wiring the device.To Isolated thermal sensor complete the installation,the 13 detector plugs into its base with a simple Stop-Drop'N Lock action. Plug-in design(base included) In-line terminals Intelligence.To reduce the likelihood of nuisance alarms,all P detectors are equipped with both drift compensation and Flexible mounting options smoothing algorithms.These capabilities minimize both short-and Stop-Drop'N Lock"attachment to the base long-term causes of nuisance alarms,such as RF interference and dust accumulation.When connected to the 2W-MOD2 loop test/ Removable cover and chamber maintenance module or an i3 Ready"panel,2-wire i3 detectors can Remote maintenance signaling generate a remote maintenance signal when in a maintenance or freeze trouble condition.To measure the sensitivity of any i3 detector, Drift compensation and smoothing algorithms the SENS-RDR displays the reading,in terms of percent-per-foot •Simplified sensitivity measurement obscuration,within seconds. Dual-color LEDs Instant inspection.i3 has red and green LEDs to simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,P sounder models generate an 85 dB temporal tone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Agency Listings Should the application call for differentiating between a local and a general alarm,the P line offers an isolated thermal model,which UL O MEAETA initiates a local alarm when smoke is detected,and a general alarm MSFM 1/ LISTED APPRMEO approved approved CO.O. when the thermal sensor is activated. 3911 3::75145 7272-1653.16- 372-U2-E 2133 31CU932 CI)Smoke Detector Specifications Operating Voltage Nominal:12/24 V non-polarized LED Mode Green LED Red LED Condition Duration 2-wire:8.5 V to 35 V Power up Blink every Blink every 10 Initial LED 80 seconds 4-wire:10 V to 35 V 10 seconds seconds status Maximum Ripple Voltage 30%of applied voltage(peak to peak) indication Standby Current 2-wire:50 pA maximum average Normal Blink every 5 off 4-wire:50 NA maximum average (standby) seconds Peak Standby Current 2-wire:100 pA Out of off Blink every 5 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blink every 10 panel trouble seconds 2WTA-B:130 mA** Alarm off Solid 4-wire:4WTA-B,4WTR-B:35 mA 4WTAR-B,4WITAR-8:50 mA **Direct Power(Non-Reverse Polarity)7 130 Condition Duration mA limited by panel.Reverse Polarity Power: Initial LED 80 seconds 30 mA for the 2WTA-B in alarm;12 mA for all status other 2WTA-B units on the loop.Add 25 mA indication for the RRS-MOD reversing relay alarm current. Alarm Contact Ratings 2-wire:n/a Smoke detector shall be a System Sensor i3 Series model number 4-wire:0.5 A @ 30 V AC/DC listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Form C Contact Ratings 2 A @ 30 V AC/DC Systems.The detector shall be a combination photoelectric/thermal equipped with a sounder(model 2WTA-B,4WTA-B),a Form C relay(model 2WTR-B),a combination sounder/relay(model 4WTAR-B),or an isolated Operating Temperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detector shall include a Range mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang, Operating Humidity 0 to 95%RH non-condensing and 4-inch square back boxes with a plaster ring,or direct mount to the Range ceiling using drywall anchors.Wiring connections shall be made by means Thermal Sensor 135°F(57.2°Q fixed of SEMS screws.The detector shall allow pre-wiring of the base and the Freeze Trouble 41°F(5°C) head shall be a plug-in type.The detector shall have a nominal sensitivity Sensitivity 2.5%/ft.nominal of 2.5 percent per foot as measured in the UL smoke box.The detector Input Terminals 14-22 AWG shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- Dimensions(including 5.3 inches(134 mm)diameter,2.0 inches color LED indication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction Approximate Weight 7.1 oz(200 g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need for maintenance at the alarm control panel and and 4WITAR-13 only) shall provide a loop testing capability to verify the circuit without testing each Mounting 3'k-inch octagonal back box,4-inch octagonal detector individually.When used in conjunction with the RRS-MOD module, back box,single-gang back box,4-inch square all i3 sounder models on a loop shall sound when one sounder alarms,all shall back box with a plaster ring,direct mount to be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module control panel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max.limited by SENS-RDR Sensitivity reader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofit adapter bracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA SYSTEM ®2a;95ystem Senso,. 3825 Ohio Avenue•St.Charles,IL 60174 r�uv��r�Pe<�a:�,�„�,�bir;n�n�-oo•,.,mwrn�a<evs�r�Y;re•-,�,,:a�wnro, �� SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 N,rentp•od..ninf mann-,naudinaihel.,21 snnn,hisr.asheet. FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) ., y . -------------------------------- .FOUNDATION(2ND,) ROUGH FRAMING.& t� PLUMBING' INSULATION.PER.N.Y. y STATE ENERGY CODE S Nat W14A l A A-13 a b FINAL. OMh4s a � 2 2 •� ADDITIONAL COMMENTS, tV 5 . `��'FFQf,pC TOWN OF SOUTHOLD—BUILDING DEPARTMENT k Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 hqps://www.southoldtownny.gov oovv Date Received APPUCAMN FOR BUMMNG PERNT For Office Use Only D E I'� PERMIT NO. Building Inspector: SEP 1 221 Applications and�forms must be filled out'in theirentirety Incomplete applications will not be accepted.:Where`the Apphcantxis not the owner,anBUILDING DEPT O nener's.Authoriiation form(Page 2)shall be completed 11 O OF SOUTT ,D Date:9/15/21 OWNERS)OF PROPERTY Name:Ryan Carr ._ w 4 .- _ �x . _ SCTM#1000-126-1-7.8 Project Address:250 7th Ave Laurel NY 11948 Phone#:516-241-8277 Email: tdn@oqijline.net Mailing Address:250 7th Ave Laurel NY 11948 CONTACT'PERSON Name AMP Architecture Jess Ma ee Mailing Address: 1075 Franklinville Rd Laurel NY 11948 Phone#:516-214-0160 Email: ma ee am architect com DESIGN.PROFESSIONAL INFORMATION Name_AMP Architecture, Anthon __Portillo �_- ------- ---- ----- ----...-------- Mailing Address:1075 Franklinville Rd Laurel NY 11948 Phone#:516-214-0160 Email: _ aportillo@amparchite_ct.com CONTRACTOR INFORMATION. Name: Mailing Address: Phone#: Email: DESCRIPTION OF'PROPOSED CONSTRUCTION El New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 0 Other As-bunt $ Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 ck -` PROPERTY INFORMATION" Existing use of property:Sin l Famil Residence Intended use of property:Sin le Family Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 iNC ♦ _ w this property? ❑Yes ®No IF YES, PROVIDE A COPY. 8 Check B®x After Reading 'The owner/contractor/design°professional is responsible for all drainage and storm water issues as:provided by Chapter 236 of the Town Code.APPLICATION JS,HEREBY MADE to the Building Department for the issuance of.a Building Permit pursuant to the BuildingIone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the,,construction of buildings ; r>, additions,alterationsor for.removal or de'molit'6:as here'ln described The.applicant agreesto comply with all applicable laws,ordinar ces;building code, housin code and re uletions and to admit authorized inspectors on premises and in building(s)for.necessary inspections.False statements made herein are - g g. , punishable as a Class A demeanor pursuant to Section 210.45 of the New,York State Penal Law. Magee M Jess a Application Submitted By(print,name):AMP Architecture, g BAuthorized Agent ❑Owner .._._._ .._i....__.. Signature of Applicant: Date: STATE OF NEW YORK) 1 SS: COUNTY OF Suffolk ) AMP Architecture, Jess Magee being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith BARBARA H.TANDY Sworn before me this Notary Public,State Of Now York No. 01 TA6086001 of Qualified In Suffolk County day 20 a-I Commission Expires 01./i8/a2A�3 Notary Public PROPERTY OWNER AUTHORUATM - (Where the applicant is not the owner) I� residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 PROPERTY-INFORM,TION Existing use of property:Sid ie Famfly Residencf Intended use of.property:Single Farnily Residence - Zone or"iise district in which premises is situated: Are there any covenants and restrictionswith respect to R-40 NC this-property?-®Yes-9No-IF YES,PROVIDE fA COPY. IR Check Box After Reading:-The owmr/contractor®design-paofemitLteis respenslifletwagdrafn eazttfstrastn.vpater esas l nds ,s - Chapter 236`ofthe Towel Code.-APPWCATION 1S HEREBY MADE to the Bu'Ildiing Depar wt ibithe issramwe eta Bu Ift&Peaarxf . t�tlxe Bv�d'uig�ne., k,County, York arid other appiitWe ,Ordinances or aaiati Ordinance.oftheTown'ofSouthotdSuffol Caun hleaar additions,alterations or for removal,ordemolition astaareasedpscraia f.The"app 9'scantagrees tooomp1VvdtiialiapgVcala4etalars, l gxnf housing code and regulations and to admit authorized Inspectors an premises and in'ba;i rme" "ns<t atm ma-3e faeeeiri are •punishable as a Class A-misdemeanor pursuant to Section 210.45 of the New York State Penal Lay. v Application Submitted By(print name).AMP Architecture, Jess.Magee IgAuothardaed ftent E]Owner Signature of Applicant: 'pmt Llase � �J���y WG� w ®ate. STATE OF NEW YORK) SS: COUNTYOF Suffolk AMP Architecture, Jess Magee being duly sworn,deposes and says that(s)he is the applicant (Name of individual-signing contract)above named, aem (S)he is the en (Contractor,Agent,.Corporate Officer,-etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and.to make.and file this application;that all.statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this rn day of <. ' .2® ril IQ =k Notary Public RaS IANE SMITH PROPERTY-OWNER AUTHORIZATIO RegistrationNo.0 SM64NN 2047OW (Where the applicant is not the owner) Qualified in Suffolk county Commission Expires August 9,20_L5_ CI, residing at J C qq do hereby,authorize +A( A,,d o apply on, my behalf-to the Town of Southold Building Department for approvA as des rib herein. q , 60 Owner's Signature ®ate Gt, <r Print Owner's Name 2 � n TOWN.QP St�llTl�t3LU ` g Ttii ift t Hall annex X4875 I' M Rtiatl oath Pd Nee York 119774959 A , g .,� s ne"(631)7664' FAX, 631)r`765.4502, T�10p6p 802, rogert(ftbmbolrtonn """ eid o V utbold . R(CINFORMA 00.rn any"Farris. K , , ame y ... ., ,..E nte , P�a�ne Nei: �1 , Name,: '. . Address: C�c�a�; trot.. Bld .Permit Tax W Chi tridt: X1909•, Seion a • BIC i . 7,- ,, BRIEF DES(,*RIP tail OF WORK-(PIe"se.,Print cwrlyy Chole All That:,Apply: Js Job ready for inspection?., Y851 Nth;, RO"Uah.1n bo you need,a Temp C'rtifcat ?. Y S,1 Is ed:C3r1 Temp fnform'atfon (Al tnro� atlo r gUlr d): Service Size 1 Ph 3 PhSize; Ar Old Meter# tet t New Service L Fire Reconnect- Flood Reconnect-,Service Reconnected W Underground-overhead Underground Laterals 1 2 H Frame Foie VWork done on Service? Y N Additional Informations f PAYMENT DUE WITH APPLICATION Request tar 9nspectlon Fo", xis >b t , .e x" .r.,� f .r{„ ,: • w'i'..a V s'a*� `5e "'. .r,sr I 1. s:�i ,�� ,��x 95.E-�,S '^. � '` Cry` h° `"T a� ' �� ax' r°{ ,T 111 Agg R" i, ate` `,r 7 +w s` r �, `,'. v ', s ro aha w .� a s a£M "S x g;-4 Q >v w '' `., $,., F��,. aG ,a .„a s � rd!,� "' `n aka� . �.,, a �, .i a8. , + s 3a - n11 e._. �ro 1 1, cy. Js rrP” e<e� "�` ,c C*11 #c r ° �« �x-x.?,.'' t y+ °a x`' - S .m' '`'�. 71 �..E_`''v r v '^^4 a c .�. u� ' 'v a y. a e �i, 'v c Z;"'��' w 'h ri ,� f$'^ �,,,+¢'' ? iia a c„'s"� sr 4'11111 11 �, =, a h b a�' -.n �i$Al 's e#, ° .: ,a"1;11—I qua } a L � z' i s a € �2�k �d W;hM w �i't �*s�,�s,.fi e":. , .d �� �� "` °y ,�� � 6.E � "� i us,I �,} " `c` �7'a; ( y' � �Y{y�y y AUNT � "L(t4 .k,11111"ttt� .t�``� 1 •1 3*r saa P s" „� yv� 3' 1wx A d 41.� ,a F«9E4d4' +� B / J t ry 7Y�{. C3 ',# µ¢�(�aV S [7i k 'i1`$ z k t i a"7 1 k +'' yy4 a g{` f§� Sf3 C T 1� � rte; o-3 :1 I r k w`�° $I r f ' k -1 aC Near, �I TlC��,p L ` { ' z �, �` ' 1. (A111n#� afigtt R 11 , � � � '' z u Q � '* 'F,,*-"»1�Q S "'4: _� `o-Mc [Q4y Y�c44S ,.q �J l,.,.�b p� a i �4y ,.f" P "^�9 Cr. ; defS C. YWN � �fn s�y44 o Ta/.. .4.Y 5 �r , 1 •4 Zo r < f" �s sr tl �+�.�.� ✓» r 1 pf lr6i tit, , sQ {1r 1 s T `e y ,, ' a'3' : QQ3p� – � 9 --vm yT}`. "r . + § '#tX F' .v` eq 3k •17t����I 'll 7* _ 1 T ! VA � �,� � " � � G (All lnforr a# '. �ix- N�t7 � [an Rqu�r1­3,ad) _IIrX. % � r ti. d i t 'F xa'Mi i:� # �I � 11 11 � J 77 Y. � r .. ,,-, a T � i k , , 04� 11 ° L 15 ttC � } �' ' I " -1 11'.. "'—^^-- c r CC1c'�11 a s a,� I a�" �� �: .�s�GtlOf1 a y11;, �j ry �b €'ray .:�' - 4•c f �tL7�V�+K - r s, c. ras fit* dL7(L� Ili y f �F 7 � , � / /j� C} `,CR1PTtC}1V lJF WQR 1NC� l of fi C UDE SQUARE�FC3t)fiAGE p a _¢ r �� 3 l11$ teas1�11e Pnnt Clearly x. � r I 11 a % r 11, ,�,� � x N � 'W t y tivr s q 1-1 �� , � � � �.��ft> square oota e , W r . 'll - 4 '�'�J"[rt � S� ""SE ."� �4/'LA"�I 1(i' Z S Y 1` q�.{/a^,�a'Y � Y hs II _ wF .iimrti€Ic�t g YDS t10 r u x_= iss n ed , ° � �' : AilEnf4miatton required} °` v err , a�X, `j ` 11 E 1 � z f t aPh xi�e 11."# et",`S �dMetiers �nll�rI� 11 `° a " ,� � 11 �N ., 4 F , 1Ge�{eCOC1CIE:C�t��1Rt�E:tC�Ta�111Cd rgrp � " ` '' i - %E] I . I I - - , ' �1 . r : . a — '111 l I. � . -11 11 I . ., �_- .�.:_ . . _ . . .... _ . _ . PERMIT 14 Address: Switches Outlets G F I's Surface Sconces HH s UC Lts Fans . Fridge H Exhaust Oven W/O Smokes DW Mini. Carbon .10.6 :_... Generator. . :.... ..; Combo Co" tops ran fere AC AH Hood Service . t ..:.. Amps Have-' Used Special: 00 e �!i( Comments: 11- I-- M 51,�„I 1, 96a 4 Q - . 1 m, �r 11; � 4-% t T '� 1�y o`'. �, ,�. 4`" D ,,, - Z_ O I %.- 1 'i E ­ . I - . �_ p _ ,: : .1 ,W N -i I - %-I 11 ,"­­­ " �� 11-- %-i z_ I I I .11 ,,, �, `-_1 \11 I ,,,, , I Iz . " I " , , I I i 11 I , l , R-v R -�,j e; ,. , , �.. I ,�, , , Aw =7111 - , I W -, """", 11", I'll 11, I " I 11 I , I I "'\1, " . Ljj >: 1 -1 R", ,, , \ , ", i" I'll 11�1 ""\, ,�', . %iP, I : 1 ___ ­ \ ., pJ to ,� f.>"'f ", , " � ,' z ,, �11 \\c e. . `,x,, >,,,, ` `... .o T .�>Y I ,.g \\ �\\\ {j \ ` . At W F\ > x3. � ': , eyIll@ ',� J T >'�, "" ---� I- ,> J 0 t y F- Lfl > 11 v N� \\,\ Y max• .t' .. LL, O 4? ,..r' ... \�.., �•,"R. ' \` ii, \\ . a, e \, �� GT ��� O \ o :, 0 x „ LO W„ „ „ r ::; f.tcs - a. - �. z :. a. Y,i :\` p a'.\ v \. �: s. !: AP V �- It* DO 4 D �:� � T� S N yf, .',. Z f` .. , �.. „ IX , T ,,' n ,,. A. - - „ e qwe DATE: x,. ' �Ea //�G O N J R B.P a' „ „ • ALSC�4L I ZX I ST I NC I N I SHAD BSEMNT. _ ci xA \ R O } .. ..e I, " ..,. �-'x� +f..".. .. - _w _ w...a. ...>.._...»....w - =�.,u.....�..a.-R.._r..,.-a..-.,.«.-w.....w.....K-.=.x w.«=. ,,.... \. . FEE: 6 F 1-- r, I Y: +Q SUBJECT PROPERTY ,� . `v '; �, Z n , Nl"'i"T'll, PRUJ%GT / ZONING DATA"'r \�, '> .� ,; " : �:l, , NOTIFY BUILDING I,F W r ART M E ! A �; T `:;H •\\ ° ��:.,\. . �,; # - _- ._ .. .,I 765-1 2 8 AM TO a Fr'ld FOR HE Q J " ` �\ £° . r TAX MAP 1000-126-1-7.8 l' J 00 c. T s 4F �` �> R fi FOLLOWING INSPECTIONS: - �s �,; - _ - _- - - - �� -_ ;: „ _. > O T „ ,- 1. FOUND ^_ x::~ w, _ ,• ATION - TWO O , t - - - - - - -- - --- - -- ------------- RE Z .r �; -- - - - - - - -- - - IGT - .,, �> x, ZONING DISTRICT ).( 1 QUI D O i , F _ POURE - r-i F OR r-i \, �:: D CONC �vll�111\11',. : y.` ,, PROJECT LOCATION &SCOPE r-I :. °:. 2. ROU - Y . ^° , > I LOT AREA p 6 GN FRAMING & PLUM � � ACRES G ZONING DATA Z -- 3 INS N „ F ., , ' , , \\: .' \;0` GENERAL NOTES - 4. FINAL �T Q Z e-I <:e,A r '':� ^� „ ` �`, , «: - Gofo 38515 x/14/2016 L CONSTR,J . tnN MU J N >^ ENERGY TABLE E W <.• a � : V �. ry91\1 x \ „ u„> "' rt --_ - - - - - ---- - - - - __ - Gofo - 38633 11/2/2016 ALL COQSTRUCTh;i� 1`�s� O , :, THE ,�`, .,\,`r . M % ,' „ \ „ - -- -- - 0� 00 MENT PLAN R t ) _ -- - - -- -- OF THE�, t � � ,,:, JI 4LL T EQUIREMENTS E EXISTING BASE NEW ONE ` �� � � � ?, z. �� CODES F I . �° T e•,, Afl r Loop Z NOT POh„ O :" "� `' -_- .__ �w_._.. - __.._-,_.,._ �,_ DES K --�--�- FEMA F X STATE N RAS '�I Fr�R GN OR CONS TION --,----I RU ____ _.,,. T C ROBS. li, e I� r a r 1 _ _.,,_.,..,.._.,. ��_ n ,'' "* .„ , _v..__,.�____.w__._ LOCATION M � � F- 101 .00 - HABITABLE SPACE µ EXISTING IL PROPOSED I, S _ _ _ _ - - -� - ___ =11 _ =-==i DWV WATER SUPPLY RISER I W ; GAS RISER - - - _--- - t ---_- --_-- , . COMPLY WITH ALL CODE OF .. � BASEMENT FLOOR AREA 625 S.F. 625 S.F. I SCALE: NTS I - NEW YORK ST v ATE & TOWN DES W _ I _ _ _ ______ _ PLUI:'."3ERCERTIFICATION AS REQUIRED AND GONDIT( '.I, OF f- - - GENERAL CARPENTRY WOOD FRAMING MATERIAL STANDARDS CERTIFICATE OF OCCUPANC;YTV` � V J GLASS WINDCW5 AND DOORS I. NO WORK TO START UNTIL APPROVED PLANS ARE OBTAINED FROM THE I. ALL LUMBER SHALL BE DOUGLAS FIR LARCH#2 8 BETTER (Fb = 8.75) UNLESS THE PROVISIONS OF THIS STANDARD ARE NOT INTENDED TO PREVENT THE USE 1T SPECIFICALLY • ALL GLASS TO BE INSULATED LOW-E,UNLE55 OTHERWISE SPECIFIED. GYPSUM WALL BOARD C(dltl!^I n' Ari ni�� APPLICABLE BUILDING DEPARTMENT. OTHERWISE NOTED. OF ANY PRESCRIBED HEIAL OF,REIN. WHEN IODAN BE CONSTRUCTION SHOW LAND THE AUTHORITY HAVING COMPOUND MET1. (5YP5UM HOD. SYSTEMS SHALL BE OF A TAPE JOINT AND JOINT SOLDER USED IN WATER -` � I BcF� Q . 2. ALL LUMBER IN CRAWL SPACES TO BE IS" ABOVE SCRATCH GOAT. MAINTAIN JURISDICTION FINDS BY EXPERIENCE, MODELING, OR TESTING BY AN APPROVED 2. GLASS DOORS AND WINDOWS SHALL NOT BE INSTALLED UNTIL PROPER C h,;,n, .^ ^. `'..;.`V C n rntiry r ti _ :,,. _,. 2. ALL CONSTRUCTION SHALL BE PERFORMED IN A WORKMAN LIKE MANNER. CLEARANCES ARE PROVIDED. SUPPLY SYSTEM CANNOT UJTtI'll ALL DIMENSIONS, CONDITIONS, AND APPLICABLE INFORMATION OF EXISTING 8" MIN. FOUNDATION EXPOSURE. AGENCY, THAT A PRODUCT OR PROCEDURE PROVIDES EQUIVALENT OR 2. ALL GYPSUM BOARD SHALL BE I/2 ON WALLS AND CEILING, UNLE55 . EXCEED 2/10 OF 1% LEAD, N ^ `�� t ., GREATER STRUCTURAL SAFETY OR DURABILITY, SUCH PRODUCT OR PROCEDURE 3. ALL SLIDII� CLASS DOORS, SKYLIGHTS, AND ANY GLASS UNIT INSTALLED OTHERWISE NOTED. WATER RESISTANT (W.R) AT BATHROOMS AND WHERE , - w 5TRU0TURE/SITE SHALL BE FIELD VERIFIED BY GENERAL CONTRACTOR. 3. SILLS TO BE P.T. AND SECURELY FLASHED WITH A TERMITE SHIELD, ALSO SHALL BE DEEMED TO CONFORM TO THE REGUIREMENT5 OF THIS DOCUMENT WITHIN IS" OF FINI5HED FLOOR SHALL BE OF INSULATED TEMPERED GLASS, DEEMED APPLICABLE. `'1 PROVIDE SILL SEAL/INSULATION. 51ZE OF SILL TO BE (2) 2"xb", UNLE55 (1) 2"xb" (THIS DOCUMENT 15 TO MEAN A REFERENCE TO THE CURRENT AMERICAN WOOD /" 3. ALL WORK SHALL CONFORM TO NATIONAL, STATE, AND LOCAL GORES UNLESS OTHERWISE NOTED. OCCUPANCY OR IS NECESSARY TO MATCH FLOOR HEIGHTS WITH THE EXISTING STRUCTURE. COUNCILS WOOD FRAME CONSTRUCTION MANUAL AND THIS PS FORMAT, AS 3. 5/&", ONE HOUR RATED, TYPE X' GYPSUM BOARD ON CEILING AND WALLS AND AUTHORITIES HAVING JURISDICTION. APPLICABLE AS A DERIVED WORK). (WHERE APPLICABLE) AT HEAT PRODUCING EQUIPMENT TO EXTEND THREE FEET 4. ALL GLA55 UNITS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH p �;�,,. 4. ALL UNNOTED OR NON-VISIBLE EASEMENTS ARE THE RESPONSIBILITY 4. AT FLUSH FRAMING USE 16 GAGE METAL JOISTS HANGERS BY "TECO" OR MANUFACTURER'S SPECIFICATIONS. IN EACH DIRECTION BEYOND THE UNIT(S). ALSO AT HEAT PRODUCING RLUMBiNC OF THE OWNER/BUILDER EQUAL. 1. IDENTIFICATION: ALL SOLID-SAWN LUMBER, GLUED LAMINATED TIMBER, EQUIPMENT, CONCRETE FLOOR OR IF PLACED ON WOOD FRAME, INSTALL ALL PLUMBING WASTE USE IS UNLAWFUL PREFABRICATED WOOD I-JOISTS, STRUOTURAL COMPOSITE LUMBER, CONCRETE PANELS OF 5/8" THIGKNE55 MINIMUM. 5. MINIMUM, DOUBLE HEADERS AND TRIMMERS AROUND ALL OPENINGS IN PREFABRICATED WOOD TRUSSES, GYPSUM, HARDBOARD, AND STRUCTURAL 5. ALL WINDONS TO IO CAULKED AND SEALED AS PER NEW YORK STATE WATER LINES NV,E[- 5. ANY OMISSIONS OR DISCREPANCIES OF PLANS AND/OR JOB CONDITIONS ENERGY CONSERVATION CONSTRUCTION CODE. TIS ING.BEFORE C,O1iERiPdG ` WITHOUT CERTIFICA1 " SHALL BE CLARIFIED WITH THE ARCHITE'.CT/EN5INEER BEFORE PROCEEDING FLOORS, ROOFS, AND WALLS. PANELS, 5HALL CONFORM TO THE APPLICABLE STANDARDS OR GRADING 4. FINISH JOINTS, J-BEADS, NAIL DIMPLES, CORNERS, AND EDGES SHALL BE WITH THE WORK. RULES SPECIFIED IN 1.1 THROUGH 1.8. 6. PROVIDE FLASHING PANS UNDER ALL 5LIDINO GLASS DOORS, WINDOWS, OR TAPED AND RECEIVE THREE GOATS OF JOINT COMPOUND. ALLOW 24 HOURS OF OCCUPANCY 6. DOUBLE ALL JOISTS UNDER PARALLEL PARTITIONS, POSTS, AND BATH TUBS, ANY OTHER TYPE OF GLA55 UNIT WHEN WITHIN 6" OF AN EXTERIOR SURFACE. TO DRY BETWEEN GOATS. FINAL GOAT TO BE SANDED SMOOTH. 6. NO DEVIATIONS OR CHANGES TO THE STRUCTURAL SYSTEM SHALL BE MADE U.O.N. I.I. LUMBER: ALL WOOD MEMBERS USED FOR LOAD-BEARING PURPOSES, ELECTRICAL INCLUDING END-JOINTED AND EDGE-GLUED LUMBER, SHALL BE IDENTIFIED -1. ALL EXTERIOR DOORS ARE TO BE WEATHERED STRIPPED AND PROVIDE ALL 5. METAL CORNER BEAD TO BE USED ON ALL OUTSIDE CORNERS AND AROUND UNLESS APPROVED BY THE ARGHITEGT/ENGINEER. -1• ALL BEAMS, GIRDERS, ETC. TO HAVE MIN. OF 3-1/2" BEARING BY THE GRADEMARK OF A LUMBER GRADING OR INSPECTION AGENCY SCREENS AND HARDWARE NECESSARY FOR PROPER FUNCTION OF SUCH UNITS. ALL OPENINGS. INSPECTION REQUIRE[ WHICH PARTICIPATES IN AN ACCREDITATION PROGRAM, SUCH AS THE RETAVI STORM WATER RUNOFF ( 1 7. CONTRACTOR TO VERIFY DIMENSIONS OF FOUNDATION WITH FLOOR PLANS 8. MIN. HEADER TO BE (2) 2"x10" UNLESS OTHERWISE NOTED. AMERICAN LUMBER STANDARDS COMMITTEE OR EQUIVALENT. THE 6. FASTEN GYPSUM BOARD AS PER FASTENING SCHEDULE ON PAGE 6-003. I l BEFORE THE START OF FRAMING GRADEMARK SHALL INCLUDE AN EASILY DISTINGUISHABLE MARK OR 8. ALL GLA55 IS TO BE FREE OF SCRATCHES AND IMPERFECTIONS. GLASS PURSUANT TO CHAPTER 236 SHOULD BE GJARANTEED BY THE MANUFACTURER FOR A PERIOD OF 5 YEARS. 8. DRY WELLS A5 REQUIRED BY STATE AND LOCAL CODES. q, ALL WOOD SILLS AND WOOD IN CONTACT WITH MASONRY/CONCRETE TO BE INSIGNIA OF THE GRADING AGENCY WHICH COMPLIES WITH THE INSULATION OF THE TOWN CODE, I P.T. REQUIREMENTS OF U.S. DEPARTMENT OF COMMERCE P520-qq. q. ALL WINDOWS TO BE ANDERSEN. IF CONTRACTOR 15 TO SUBSTITUTE WITH dower door I I. ALL EXTERIOR WALL5 AND ROOFS SHALL BE INSULATED WITH FOIL FACED q. DO NOT 50ALE DRAWINGS, WRITTEN DIMENSIONS TAKE PRECEDENCE ANOTHER WINDOW MANUFACTURER, IT IS THE RESPONSIBILITY OF THE FIBERGLASS BATT INSULATION BY JOHN MANVILLE OR APPROVED EQUAL. (*,3t','�*3,`1 10. ALL EXTERIOR SHEATHING SHALL BE NAILED AS PER FASTENING SCHEDULE 1.2. GLUED LAMINATED TIMBERS: GLUED LAMINATED TIMBERS SHALL MEET CONTRACTOR TO VERIFY THAT THE CHARACTERISTICS OF THE WINDOW MATCH and ductwork °' THE PROVISIONS OF ANSI/ALTO A I qO.1 STRUCTURAL GLUED LAMINATED FOIL TO BE PLACED TOWARD WARM SIDE. 10. OWNER/BUILDER ARE RESPONSIBLE FOR ALL INSPECTIONS, APPROVALS, ON PAGE G-003. GENERALLY, SHEATHING IS OF I/2 THICKNESS ON WALLS AND THE CHARACTERISTICS OF THE ANDERSEN WINDOW SPECIFIED. THEtestingI ROOF AND 15 OF COX GRADE, UNLESS OTHERWISE NOTED. SEE FLOOR PLANS TIMBERS. CHARACTERISTICS ARE AS FOLLOWS, BUT NOT LIMITED TO: DE51ON PRESSURE, testing required. I , CERTIFICATES, CERT. OF OCCUPANCY OR COMPLETION AND U.L. APPROVAL 2. PROVIDE 2" R-10 RIGID FOAM INSULATION FOR EXTERIOR FOUNDATION FOR ADDITIONAL NAILING OR DIFFERENT NAILING REGUIREMENT5 WHEN ROUGH OPENNO,U-FACTOR, LIGHT AREA, VENT AREA, AND EGRESS WALLS FROM 6" BELOW GRADE TO 24" BELOW GRADE IF DESIRED BY � P('- rZc i.,irc 1.3. PREFABRICATED WOOD I-JOISTS: ASSEMBLIES USING PREFABRICATED _ ,_.. ;',, �, , j 11. THESE SET OF DRAWINGS ARE THE PROPERTY OF ANTHONY PORTILLO, RA APPLICABLE. REGUIREMENT5. CONTRACTOR OR OWNER. CARE SHOULD BE TAKEN NOT TO DAMAGE WOOD I-JOISTS SHALL MEET THE PROVISIONS OF ASTM D5055 AND SHALL NOT BE ALTERED OR BE RE:PRODUGED WITHOUT WRITTEN STANDARD SPEGIFIGATION FOR ESTABLISHING AND MONITORING FOUNDATION WATERPROOFING. I 1 11. SUB FLOORING, GENERALLY, TO BE OF 3/4" THICKNESS AND OF GDX GRADE. 10. WINDOWS IN TUB/SHOWER ENCLOSURES AND WITHIN STAIRWAYS 5HALL BE PERMISSION FROM THE ARCHITECT. NAILING AS PER FASTENING SCHEDULE ON PAGE 0-003 AND GLUED, U.O.N. STRUCTURAL CAPACITIES OF PREFABRICATED WOOD I-JOISTS, TH15 TEMPERED GLASS: �: 12. THE ARCHITECT IS NOT RETAINED FOR SUPERVISION OF THE WORK AND IS DOCUMENT, THE GOVERNING BUILDING CODE AND ANY ADDITIONAL 3. GENERALLY, UNLE55 NOTED OTHERWISE, INSULATE AS FOLLOW. i - g" R-30 FOR FLAT CEILINGS 12. EXTERIOR 5HEATHING TO BE COVERED WIT- "YVEK' HOUSE WRAP OR REGUIREMENT5 A5 SET FORTH IN THE MANUFACTURER'S GORE 11. EXTERIOR GLAZ NG SHALL BE PROTECTED FROM WINDBORNE DEBRIS. I RESPONSIBLE FOR DESIGN INTENT ONLY. APPROVED EQUAL. EVALUATION REPORT. GLAZED OPENING PROTECTION SHALL MEET THE REQUIREMENTS OF THE LARGE - 8.25" R-306 FOR VAULTED AND CATHEDRAL GEILINES MISSILE TEST OF ASTM Elggb AND ASTM EI886 AS MODIFIED BY 2020 NY5 BG - 3.5 R-13 FOR 2'x4" WALL CONSTRUCTION 1 13. THE CONTRACTOR SHALL OBTAIN CERTIFICATE OF OCCUPANCY. 1.4. STRUCTURAL COMPOSITE LUMBER: SINGLE MEMBERS OR ASSEMBLIES - 5.25" R-21 FOR 2"x6' WALL CONSTRUCTION . I 13. BLOCK EXTERIOR STUD WALLS TE HALF STORY HEIGHTS AND AT SECTION 301.2.1.2.1. GARAGE DOOR GLAZED OPENING PROTECTION SHALL MEET - 5.25" R-21 FOR FLOORS UNSUPPORTED EDGE SEAMS OF EXTERIOR SHEATHING. USING STRUCTURAL GOMP051TE LUMBER SHALL MEET THE PROVISIONS OF I 14. THE CONTRACTOR SHALL KEEP PREMISES REASONABLY GLEAN AT ALL A57M D5456 STANDARD SPECIFICATION FOR EVALUATION OF THE REQUIREMENTS OF AN APPROVED IMPACT-RESISTANT STANDARD OR TIMES. AT THE COMPLETION OF WORK, THE CONTRACTOR SHALL REMOVE ALL 14. PROVIDE 'X' GRO55 BRACING AT JOISTS, S7-UD5, AND RAFTERS WHEN SPANS STRUCTURAL COMPOSITE LUMBER PRODUCTS, THIS DOCUMEN, THE ANSI/DASMA 115. RUBBISH, WASTE MATERIALS, TOOLS, ETA:., GLEAN GLA55 AND LEAVE WORK GOVERNING E3UILDING GODS, AND ANY ADDITIONAL REQUIREMENTS AS BROOM GLEAN. EXCEED &'-O" AND AT EVERY 8'-O"• 12. AS AN ALTERNATIVE TO NOTE #11 ABOVE, WOOD STRUCTURAL PANELS WITH SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORT. i 15. TOP PLATES TO BE DOUBLED AND LAPPED AT CORNERS, SEE AL50 PAGE A THICKNESS OF NOT LESS THAN �" AND A SPAN OF NOT MORE THAN 8' SHALL 15. THE CONTRACTOR SHALL CARRY WORKMAN'S COMPENSATION AND GENERAL G-003. 1.5. PREFABRICATED WOOD TRUSSES: ASSEMBLIES U51NO PREFABRICATED BE PERMITTED AS GLAZING PROTECTION. PANELS SHALL BE PRECUT AND i LIABILITY INSURANCE. ALL SHALL COMPLY WITH STATE AND LOCAL CODES WOOD TRU55ES SHALL MEET THE PROVISIONS OF THIS DOCUMENT, THE ATTACHED TO THE FRAMING SURROUNDING THE OPENING. PANELS SHALL BE ( i AND ORDINANCES. GOVERNING BUILDING GODS, AND ANY ADDITIONAL REQUIREMENTS AS PREDRILLED AND SECURED WITH THE ATTACHMENT HARDWARE PROVIDED AS ►_ 16. APPLY ALL CONDITIONS ADDRE55ED IN FASTENING SCHEDULE AS Z SET FORTH IN AN51/TPI I NATIONAL DE51ON STANDARD FOR METAL PLATE PER THE ANG-IORAGE METHOD SELECTED IN ACCORDANCE WITH TABLE W NECESSARY. I l I6. THE CONTRACTOR SHOULD FULLY GUARANTEE HIS WORK AND THE WORK OF CONNECTED WOOD TRUSS GONSTRUGTION, THE TRU55 DESIGN DRAWINGS, R301.2.1.2. A-TAGHMENT HARDWARE SHALL BE PERMANENT THE 5UB-CONTRACTORS FOR A PERIOD OF AT LEAST ONE YEAR AFTER OR THE MANUFACTURER'S GODS EVALUATION REPORT. CORROSION-RFAND THE ANCHORS SHALL BE PERMANENTLY INSTALLED O COMPLETION OF PROJECT. 17. PROVIDE ALL NAILING AND STRAPPING ADDRESSED ON PAGES 6-003. ON THE BUILDING. 0 I.6. GYPSUM: GYPSUM MATERIAL USED IN A STRUCTURAL APPLICATION SHALL - I - - 1-1. THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLE55 THE OWNER, 18. AT WET WALL PARALLEL TO JOISTS FRAME DOUBLE JOIST AS PER GORE. �- GENERALLY, SEPARATE DOUBLE JOIST THE THIGKNE55 OF WALL ABOVE. SUB MEET THE PROVISIONS OF ASTM 636 SPECIFICATION FOR GYPSUM ARGHITEGT/ENGINEER, AND THEIR ASEN'r5 AND EMPLOYEES FROM AND WALLBOARD, ASTM 03-1 SPECIFICATION FOR GYPSUM LATH, OR ASTM 07q _ _ AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING FLOOR SHALL NEVER EXCEED A I6 SPAN. w-.-_ _--___ _ I _---_-__...------_ ATTORNEYS FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF SPECIFICATION FOR GYPSUM SHEATHING BOARD. S OR EXPENSE Iq. AT ROUGH OPENINGS PROVIDE ALL APPLICABLE NAILING AND STRAPPING , THE WORK PROVIDED THAT ANY SUCH CLAIM, DAMAGE, LOS (A) AS PER PAGE G-003. 1.7. HARDBOARD: HARDBOARD USED IN A STRUCTURAL APPLICATION SHALL PLUMBING ti.i I 15 ATTRIBUTABLE TO BODILY INJURY, SICKNESS, DISEASE OR DEATH OR TO MEET THE PROVISIONS OF ANSI/AHA A135.4 BASIC HARDBOARD OF 1. CONTRAOTCR SHALL INSTALL WATER SUPPLY, DRAIN, WASTE, AND VENT (DWV) F_ I INJURY TO OR DESTRUCTION OF TANGIBLE PROPERTY (OTHER THAN THE WORK ANSI/AHA AL35.6 HARDBOARD SIDING. SYSTEMS TO NY5 PLUMBING CODE AND NYS DEC REGULATIONS. a I , ' ITSELF INGLUDIN6 THE LO55 OR USE RE'.SULTINS THEREFROM). (B) IS CAUSED IN 20. "P.T. SPECIFIES PRESSURE PRE5ERVA7IVELY TREATED LUMBER IN ACCORDANCE w/ AWPA 022;WHERE DRILLING AND/OR GUTTING OCCURS, FIELD Q I 1 WHOLE OR IN PART BY ANY NEGLIGENT ACT OR OMISSION OF THE TREAT LUMBER w/ COPPER NAPTHENATE WHICH SHALL CONTAIN 2% COPPER I.8 STRUCTURAL PANELS: 2. PROVIDE HOT AND GOLD SHUT OFF VALVES AT ALL FIXTURES. CONTRACTOR, ANY 5UBCONTRAOTOR, ANYONE DIRECTLY OR INDIRECTLY METAL BY REPEATED BRUSHING, DIPPING, OR SOAKING UNTIL THE WOOD PROJECT: EMPLOYED BY ANY OF THEM, OR ANYONE FOR WHOSE ACTS ANY OF THEM MAY ABSORBS NO MORE. ALSO, FOR HARDWARE USsED WITH P.T. LUMBER, 1.8.1. PLYWOOD: PLYWOOD USED IN STRUCTURAL APPLICATIONS SHALL 3• ALL WATER PIPING TO HAVE GLEAN OUTS AT ALL CHANGES IN DIRECTION BE LIABLE REGARDLESS OF WHETHER OR NOT IT 15 CAUSED IN PART BY A CONTRACTOR 15 TO INSTALL HARDWARE THAT 15 SPECIFIED BY P.T. LUMBER MEET THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE AND AT BASE OF VERTICAL WASTE PIPES. PARTY INDEMNIFIED HEREUNDER. MANUFACTURER SUCH A5: HANGERS, NAILS, 50FZEWS, FLASHING, ANCHOR BOLTS, VOLUNTARY PRODUCT STANDARD I (P5 1) 00N5TRUOTION AND 18. ALL MATERIALS, ASSEMBLIES, AND METHOD OF CONSTRUCTION INGLUDIN6 ETC. FOR LOCATIONS SUCH AS: LEDGER BD., SLL PLATE, DECK CONSTRUCTION, INDUSTRIAL PLYWOOD, U.S. DEPARTMENT OF COMMERCE VOLUNTARY E 4" GAET IRON THROUGH FOUNDATION WALL AND PITCHED AT I/8" PER CARR BUT NOT LIMITED TO FORM-WORK, BLOCK-WORK, FRAMING, NAILING, PLACING ETC. ANY REFERENCES TO GGA ARE TO REPLACED WITH P.T. PRODUCT STANDARD 2 (P52) PERFORMANCE STANDARD FOR RESIDENCE OF CONCRETE, ETC. ARE TO BE CAREFULLY SUPERVISED BY THE CONTRACTOR WOOD-BASED STRUCTURAL- USE PANELS, APPLICABLE CODE TO BE SURE THEY ARE IN ACCORDANCE: WITH THE DRAWINGS, SPECIFICATIONS, 21. LVL (LAMINATED VENEER LUMBER) DENOTES EITHER OF THE FOLLOWING: EVALUATION REPORTS. 5. GENERAL TRAP AND WASTE SIZES A5 FOLLOWS, UNLESS OTHERWISE NOTED: A. TRU55 JOIST McMILLIAN IAE MICROLA"I - DI5H WASHER.........................................2" APPLICABLE CODES AND GOOD PRACTICE. DEVIATIONS FROM THE DRAWINGS B• GEORGIA PACIFIC 2.OE G-P LAM 1.8.2. ORIENTED-STRAND BOARD (OSB), WAFERBOARD ORIENTED-5TRAND - KITCHEN 51NK........................................2" AND SPECIFICATIONS WILL NOT BE PERMITTED WITHOUT WRITTEN PSL (PARALLEL STRAND LUMBER) DENOTE4: BOARD OR WAFERBOARD USED IN STRUCTURAL IONS SHALL MEET - LAVATORY...............................................2" AUTHORIZATION OF 'SHE ARGHITECT/ENGINEER. - SHOWER/TUB 2" A. TRU55 JOIST McMILLIAN 2.0E PARALLAM, THE PROVISIONS OF U.S. DEPARTMENT OF COMMERCE VOLUNTARY ALL TO BE INSTALLED AS PER MANU. 5PEG.'s - PRODUCT STANDARD 2 (P52) PERFORMANCE VOLUNTARY PRODUCT - TOILET........................................................3" 250 7TH AVENUE let. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY SHOP DRAWINGS STANDARD FOR WOOD-BASED STRUCTURAL- USE PANELS OR LAUNDRY .................................................2 NEEDED, UNLESS OTHERWISE SPECIFIED. ALL DIMENSIONS AND CONDITIONS 22. I-JOIST FLOOR SYSTEMS SHALL BE IN ACCORDANCE WITH THE WOOD APPLICABLE CODE EVALUATION REPORTS. - FLOOR DRAIN..........................................3" LAUREL, NY, 11948 PERTAINING ARE TO BE FIELD VERIFIED. FRAMING MATERIAL STANDARDS SECTION, THE EiOVERNINO BUILDING CODE, 20. CONTRACTOR TO REMOVE d RELOCATE A5 REQUIRED ALL EXISTING WORK AND ANY ADDITIONAL REQUIREMENTS SET FORTH IN THE MANUFACTURER'S 1.8.3. PARTICLE BOARD: PARTICLE BOARD USED IN STRUCTURAL 6. ALL SYSOOF. TO HAVE ONE 3" MAIN VENT STACK AND INCREASED TO 4" WHICH INTERFERES WITH NEW CONSTRUCTION IN A WORKMAN LIKE MANNER. GORE EVALUATION REPORT. APPLICATIONS SHALL CONFORM TO ANSI A208.1 AND ANY THROUGH ROOF. REGUIREMENT5 AS SET FORTH IN THE MANUFACTURER'S CODE DRAWING_TITLE: 23. NOTCHES IN THE TOP OR BOTTOM EDGE OF�-'?LID SAWN RAFTERS SHALL EVALUATION REPORT. 7. PROVIDE ,-RAST-PROOF HOSE BIBS WITH EASILY ACCESSIBLE DRAIN Ec -- ------------- 21. ALL MATERIALS ARE TO BE INSTALLEDAS PER MANUFACTURERS NOT BE OUT IN THE MIDDLE ONE-THIRD OF THE FA.FTER SPAN. NOTCHES IN THE DRAIN GOOKS A5 REQ'D. HOSE BIBS SHALL BE PROVIDED WITH BACKFLOW L!:--3 21. D PROJECT LOCATION SPECIFICATIONS, UNLE55 NOTED OTHERI OUTER THIRDS OF THE SPAN SHALL NOT EXGEET" ONE-SIXTH OF THE ACTUAL 1.5.4. FIBERBOARD: FIBERBOARD USED IN STRUCTURAL APPLICATIONS PROTECTION. OC TION & SCOPE RAFTER DEPTH. WHERE NOTCHES ARE MADE AT SUPPORTS THEY SHALL NOT SHALL MEET THE PROVISIONS OF AN51/AHA AIg4.I CELLULOSIC SITE PLAN & ZONING DATA 22. PROVIDE FIREBLOGKIN6 AS PER NEW YORK ACCESSIBILITY STANDARDS. EXCEED ONE-FORTH THE ACTUAL RAFTER DEP7H BORED HOLES ARE LIMITED FIBERBOARD OR ASTM 0208 STANDARD SPECIFICATION FOR 5.WITH WASTE FLOW CLOTHES WASHERS AND LAUNDRY TUBS ARE TO BE PROVIDED 23. PLEASE NOTE THAT THESE PLANS ARE PROTECTED AGAINST ANY IN DIAMETER TO ONE-THIRD THE ACTUAL RAFTER DEPTH AND THE EDGE OF THE CELLULOSIC FIBER INSULATING BOARD. WITH BACK FLOW PROTECTION. SEP 2r2� UNAUTHORIZED USE UNDER FEDERAL LAW BY THE ARCHITECTURAL WORKS HOLE SHALL NOT BE CLOSER THAN 2 INCHES TO THE TOP OR BOTTOM EDGE5. q. THE WATER SUPPLY AND SANITARY SYSTEM SHALL COMPLY WITH LOCAL COPYRIGHT PROTECTION ACT OF IggO (AWGPA), WHICH HAS SEVERE PENALTIES. 1.8.5. STRUCTURAL PANEL SIDING STRUCTURAL PANEL SIDING USED IN HEALTH DEPARTMENT STANDARDS AND REGULATIONS. t"'D ,'"I . 24. NOTCHES IN EITHER EDGE OF STUDS SHALL NOT BE LOCATED IN THE STRUCTURAL APPLICATIONS SHALL MEET THE REQUIREMENTS OF U.S. � MIDDLE ONE-THIRD OF THE STUD LENGTH. NOTCHES IN THE OUTER THIRDS OF DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARD I 10. APPROVAL AND INSPECTION IS REQUIRED BY LOCAL JURISDICTION PRIOR 'r0`�'1"1 or, S4}j.I' T!()T,pt THE STUD LENGTH SHALL NOT EXCEED 255 OF -HE ACTUAL DEPTH. BORED (PS- 1), THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL TO CONGEALMENT OF PLUMBING. PAGE: HOLES SHALL NOT EXCEED 40% OF THE ACTUAL STUD DEPTH AND THE EDGE REQUIREMENTS AS SET FORTH IN APPLICABLE CODE EVALUATION . OF THE HOLE SHALL NOT BE CLOSER THAN 5/8"TO THE EDGE OF THE STUD. REPORTS. _ _ - 11. NOTCHING AND BORING OF STUDS, JOISTS, RAFTERS AS PER BUILDING CODE. _`_ __ _ OENERAL 1ERAL SNr�50L E) • r NEW PARTIAL HEIGHT- `--,,.` W Z O EXISTING TO BE DEMOLISHED WOOD FRAME (L.O. STL. j J = CN EXISTING TO REMAIN WHEN APPLICABLE) �\ 1 NEW WOOD FRAME (L.G. NEW FOUNDATION WALL ` r I I1� Q w STL. WHEN APPLICABLE:) NEW I-HR FIRE RATED MIN. (2) 2"x4" 5TRUCTURAL ; 4,-:r_,.• O : Z POST FOR 6'" STRUCTURAL 'i!`;_ - —"_� ~ � � WOOD FRAME (L.G. 5'fL. ��t- WHEN APPLICABLE) (MIN. (2) 2 x , M NEW 2-HR FIRE RATED P05T FOR 6" WALLS), U.O.N. �' O � a � � WOOD FRAME (L.G. STL. WHEN APPLICABLE) Z m O H � Qw J 3b'-6" 2a'-2y2" I6'-3y2" -J 00 > O Z (fl 14'-6" 12'-0" 12'-O" J TA O i azo EL'-' W (D EXIST. 2'6"WXI'6"H AWN, � _ Ln O' EXIST. EXIST. N LADDER 2'6"WXI'6"H AWN. - W O AREAWAY Q E- U ; EXI5VEGRESS) - LLI 4'10"WX3'10"H GLIDE. EXIST. �` _ J BATHROOM -- n V J 14'-6" II'-7" 6'-7" 3'-4" I Q. x = RAIN D i 1� m EXIST. - RE ION ROOM - 556 S.F. io dJ - `� DROPPED m r _ - CEILING HEIGHT _FINI5HED- -_- -- BASEBOARD HEATING �n O - r- - - O - --- HW m `Y -- :25--5" EX15T. MECH. I ROOM z UNHEATED UNFINISHED- 5m/co EXIST. GRAWLSPAGE Lu F-W N i W v iv z I r w i I EXI5t (14) RI 1 " O 95.1 UP, (12) Tr ® t 10" V + i w H Q � i 0 I I ° PROJECT: CARR RESIDENCE 250 7TH AVENUE LAUREL, NY, 11948 UNEXCAVATED 2 GAR GARAGE DRAWING TITLE: EXISTING BASEMENT PLAN PAGE: a 1 4011, JI. 0 AM ■ DATE: 08/20/21 2 OF 3 24'-0" -a'-2y 2 2 0 5 10 20 GRAPHIC SCALE 1/4"=1'-0" ' EX I ST I NO 5ASEMENT PLAN 625 50. FT. HAE3ITA5LE SFAGE; 3,072 50. FT DROSS AREA 50ALE: 1/4" = 1'-o" (L d7 Q U H O uj Z N J W � Q w >- � � Z o 0z J = Lo F- J (3) C) O C) d Lo m Z O F- Z � Z w J J 00 ` Z � (D J � O Q Z VI L'- w0 LncrT4 tO Ln w F- U w I_- U = J � J Q 4" FRESH AIR VENT THROUGH ROOF o O U Q I Q Q I i NOTE: j ALL PLUMBING WORK O j R' SHALL CONFORM TO wNOTE: I LOCAL PLUMBING CODE ALL PLUMBING # U I FUEL OAS WORK Ca I PROVIDE "A5E5C0 FF2O0 FR tL tL 1 EXPANDING FOAM" (OR EQUAL)ci Q SHALL CONFORM I TO AT ALL PENETRATIONS IN FIRE p O PLUMB NGLGODE k N 1 RATED WALLS AND V LEGEND v FUEL OAS I FLOOR5/GEILIN55. PRODUCT N N I CONFORMS TO ASTM I E 814, HOT WATER - - - - - F —————-{ SUPPLY I --- 1- - - -- ASTM I- 84, AND UL 1479 - --- - - - - - -- -- - -- -- -- - - - ----J PIPIIN1. OVEN _"ABESOO FP2O0 FR .. - - - - NATER EXPANDING FOAM (OR EQUAL) SUPPLY- - --- - -- - - -- -- -- - ------ - - - --- - -- - AT ALL PENETRATIONS AT WALLS j COTE: AND FLOORS/GEILIN05. ALL PLUMBING WORK PROVIDE "ABESCO FF2O0 FR 2.PRODUCT CONFORMS TO ASTM E 814, ASTM E 84, AND UL 1479 °.HALL CONFORM TO EXPANDING FOAM" (OR EQUAL) LOCAL PLUMBING CODE AT ALL PENETRATIONS IN FIRE RATED WALLS AND ci fj p j FLOOR5/GEILIN05. PRODUCT GLEAN OUT O CONFORMS TO ASTM E 814, O 3" AS REQ'D U ASTM E 84, AND UL 1479 N 0 F i 1 w EXIST. F.A.I. TO � w IL REMAIN I tT EXIST. WATER _- p - -- -- - --- ( - -- -- -- ---- -- -- -- - SUPPLY SYSTEM � U-- ---- -- %-- 1 ---- -- ---- G.O. _��------------------ _._ _.-. - - _ _ - _ _.._. _ ._.._.._.._.._ - - --- ---- - - - ------- �. . I - - - - -- -- - -- --- - - - -- I G.O. I I� 1 I j GAS SUPPLY -- ---1._._. -- -- BASEMENT .� 4" � v I BATHROOM _- 4" HOUSE iV I �_ I EX 1 STING I -- w EXISTING I I MAIN DRAIN C.O.: I I� i I j MECHANICAL _ I BATHROOM I ROOM TO STREET WATER MAIN EXISTING2r I 2:: 4 I I 2"1 TO SEPTIC zyI � I MECHANIC A L PROJECT: SYSTEM w ROOMI2 NI Q m I I I < < I= 4 I Q 4 CARR 1 II SHOWER 14" - --- ----- I m EBXOIISLTE.R RESIDENCE SHOWER ;xol ISLTER -- - - - - --- -- - -- --_ 250 7TH AVENUE FLUME31NO RISER - DRAIN / NASTE / VENT FLUME31 NCS RISER - SUFFL)" CCAS RISER - SUFFL "r LAUREL, NY, 11948 SCALE: NTS SCALE: NTS SCALE: NTS DRAWING TITLE: PLUMBING RISER DIAGRAMS GAS RISER DIAGRAM PAGE: -loinBMW 0, 0 DATE: 08/20/21 3 0 F 3