Loading...
HomeMy WebLinkAbout45710-Z o�ogtlFFel��oG. Town of Southold 4/8/2022 P.O.Box 1179 o - N m�� 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42973 Date: 4/8/2022 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 580 Stars Rd.,East Marion SCTM#: 473889 See/Block/Lot; 31.4-8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/3/2020 pursuant to which Building Permit No. 45710 dated 1/22/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory in-ground swimming pool fenced to code as applied for. The certificate is issued to Modern Age Home Builders LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45710 4/6/2022 PLUMBERS CERTIFICATION DATED 0 , A riz Signature SVF tx�o TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY -a BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45710 Date: 1/22/2021 Permission is hereby granted to: Modern Age Home Builders LLC 755 Waverly Ave Ste 218 Holtsville, NY 11742 To: construct accessory in-ground swimming pool as applied for. At premises located at: 580 Stars Rd., East Marion SCTM # 473889 Sec/Block/Lot# 31.-4-8 Pursuant to application dated 12/3/2020 and approved by the Building Inspector. To expire on 7/24/2022. Fees: SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $250.00 CO - SWIMMING POOL $50.00 Total: $300.00 Buil or pF S® l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 �Q sean.devline-town.southold.ny.us Southold,NY 11971-0959 Qlyc®u I�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Modern Age Builders LLC Address: 580 Stars Rd city:East Marion st: NY zip: 11939 Building Permit* 45710 Section: 31 Block: 4. Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Puccio Electric License No: 4806ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor X 1 st Floor Pool X New X Renovation 2nd Floor Spa X Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt 2 Recessed Fixtures CO2 Detectors Sub Panel X A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump 2 Other Equipment: Pentair Intellitouch 10 Circuit - 10 Used, Blower, Heater 220GFI, Pumps 220GFI, Lights 120GFI Notes: Pool Inspector Signature: Date: April 6, 2022 S.Devlin-Cert Electrical Compliance Form �aoF sooTyo ,� o �v s # # TOWN OF SOUTHOLD BUILDING DEPT. 76S-1802 INSPECTION .[ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION' [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ''[�� ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: o�/ a. Inc f u0m o- IrOJ4 r n In DATE 2 22 INSPECTOR "1 10 OF SOUTyo Ll 10 5 # * TOWN OF SOUTHOLD BUILDING DEPT. . °ycourm��' 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] "ROUGH PLBG. [. ] - FOUNDATION 2ND x [' J INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE '& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS:, G�ti DATE G Z7i INSPECTOR OF SOUTy� 5 l V s # TOWN OF SOUTHOLD BUILDING DEPT. co 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ' ] FIREPLACE & CHIMNEY ' [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) '[y0] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] P E C/O REMARKS:, . DATE � 22 INSPECTOR r PA F i, 921121211111 12 goal me �Illt!!!e_e_:as: ��isf:11111 ' ;I�II���I�IIIIIIII�1 11 _� 1tID �� +Ti•r, W� UP . �i t it III �I II II �., � +;is '+?•r IIA z y y R t { 0-1-1111�r5 t Sra Y:w.•r 1 iSTF 7 �� s. • 3 r t +Y i . 1 r 1 t • •••• - • 1 .• ••• FigivAir metrallvAl •p w '• •• • • • - A FIELD INSPECTION REPORT 'DATE COMMENTS FOUNDATION(1ST) G y FOUNDATION(2ND) ROUGH FRAMING:& y PLUMBING d \f INSULATION PER N.Y. STATE ENERGY CODE (94(AANV UA'I 11A FINAL Jo ADDITIONAL COMMENTS II- - i 1 sI� 06 o. CIA ' ItA� SVD Z �. X b wd�nsxr� o�YS°ffotr�o TOWN OF SOUTHOLD—BUILDING DEPARTMENT �o y Town Hal)Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax(631) 765-9502 Ids://www.southoldtownny.go,v For Office Use Only Da(tee keceived I _-) Fa PERMIT NO. Building Inspector: R 1 0. Applications and forms must be filled out in their entirety.Incomplete applications -" DEC - 3 2020 will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. �f I Q.� 'ATIO1 AOR l�fl�Q0 MNG PERN�l�� . Date: `;.`'j AVN�7 S 317' OWNERS)OF PROPERTY.. . Name: "Inne p,ryle �uk( f Jeri Tax Map#:SCTM#1000- 31 Physical Address: (hS� lwa rib n Phone#: J� - 7�"7- 8D 7 Email:-��-I�ft'� m Dc-Ver-n home by i)d6 Ccs+ Mailing Address: / ifve- �/�' f(b 7 S9 �/� a CONTACT.P.ERSON: Name: ...._ .. . .. . .. � : �-.... . .-els Mailing Address: kH .117 - Phone#:..�3f.- ..�.1. l��UL. .� ... ... .... ..._._. Email: -DESIGN PROFESSIONAL INFORMATION. // a,l Name: H E IFi )en( . .... .. Mailing Address: �. _..�.../..�¢..... SNdQ>!"I . ..�1 7�._�.. ... . . . .. .... .. Phone ti 0 Email: (� y ':10 -X5.3..,._.... _ I-f mar i he o. 1-a n lib—e.( CONTRACTOR INFORMATION;' Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION dew Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: �4pther b..$ Vr0, 000 Will the lot be re-graded? ❑Yes MlYo Will excess fill be removed from premises? []Yes PAO .,,PROPERTY`I NFORMATION Existing use of property: Intended use of property: c y1 .....-. Date of Purchase: Name of Former Owner: . . . ."_ 1�10 1 i j M ' i Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes LFiVo IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 2`10.45 of the New York State Penal Law. pp .,r oIn-Sr... t e_ ..By p r... . ..._. ). .,V.'P� .Y-�... ..,� d gen.. . , . A lication Submitted B rint name . uthorizeAt,.. El Own.er Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Au� (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Swor before me this 2� Jamie Francis to Public (Votary Public State of New York NO 01 FR6112394 Qualified in Suffolk County PEROWNER Al�`�@�QRB�A`�i®�9 Commission Expires July 6,2 (Where the applicant is not the owner) I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name r1. c,UFF , 1 2021 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD w BUILD 'Vii;-;`;0Tpwn Hall Annex- 54375 Main Road - PO Box 1179 ° Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cD_southoldtownny.gov - seand(a)-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10/27/2021 Company Name: Puccio Electric Contracting Inc. Name: M r jp License No.: 148(16-me email: info@puccioelectriccorp.com Phone No:(g&.194.,2pq& 1V 1 request an email copy of Certificate of Compliance Address.: 4 JOB SITE INFORMATION (All Information Required) Name: Modtrn t 44me, tit I der% Address: 'pn Nq Cross Street: Phone No.: -p7ll Bldg.Permit#: 45710 email: info@puccioelectriccorp.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Pool wiring Pool wiring Pool wiring Check All That Apply: Is job ready for inspection?: DYES [E]NO ❑Rough In ❑Final Do you need a Temp Certificate?: [-]YES ENO Issued On 10/27/2021 Temp Information: (All information required) Service SizeF-11 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals E]1D2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: Will call for inspection Will call for inspection Will call for inspection PAYMENT DUE WITH APPLICATION 11'2)—gd PC) . 100 .00 Electrical Inspection Form 2020.xlsx /�P�'v'L. 106 ,1 OSVFpQ NOv 0 1 2021 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD o' BUI�o+ �ti1. 0 wn Hall Annex - 54375 Main Road - PO Box 1179 x pWN 0 .. . . Southold, New York 11971-0959 4�. Telephone (63:1) 765-1802 - FAX.(631) 765-9502 r0err(a)southoldtownny.gov - seand(a-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10/27/2021. Company Name: Puccio Electric Contracting Inc. Name:,mar K1� License No.: email: infcy@puccioelectriccorp-.com - Phone No: 3 - q& [�]I request an email copy of Certificate of Compliance Address.: WMoyldwhll ` JOB SITE INFORMATION (All Information.Required) Name: nn h Address: 'pn Cross Street: Phone No.: - 1� Bldg.Permit#: 45710 email: info@puccioelectriccorp.com Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Pool wiring Pool wiring Pool wiring Check All That Apply: Is job ready for inspection?: DYES ONO ❑Rough In ❑Final Do you need a Temp Certificate?: ❑YES ❑✓ NO Issued On 10/27/2021 Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground [—]Overhead ; ,# Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service?',-Ely ❑N Additional Information: Will call for inspection Will call for inspection Will call for inspection PAYMENT DUE WITH APPLICATION PCI . 100 -06) 'Electrical Inspection Form 2020.xlsx 1 cC* 10O C - 9g04 02� S- , A �� in c L Leeds Expediting 134 Sequoia Drive Coram,New York 11727 631-509-4248 JenniferLeeds0255@gmail.com November 28, 2020 Town of Southold Building Department Town Hall PO Box 1179 54375 NYS Route 25 Southold,NY 11971 Attention: Amanda Nunemaker Re: Stars Road, East Marion SCTM# 1000-31-4-8 & 9 Dear Amanda: Enclosed herein you will find an application for new inground swimming pool and pool fence to code that goes along with the application I previously submitted to you for the new house. Unfortunately, I have not heard back from the Zoning Board to see if they will accept the bill of sale in place of the deed at this time. If you require any additional information or have any questions regarding this application, please do not hesitate to call or email me. Yours very truly, Jennifer Leeds Gmail Jennifer Leeds <jenniferleeds0255@gmall.com> RE: 580 Stars rd - Modern Age Home Builders 1 message Nunemaker,Amanda<Amanda.Nunemaker@town.southold.ny.us> Mon, Nov 23,2020 at 10:34 AM To: Jennifer Leeds<jenniferleeds0255@gmail.com> Ok, keep me posted. From: Jennifer Leeds [mailto:jenniferleeds0255@gmail.com] Sent: Monday, November 23, 2020 10:23 AM To: Nunemaker, Amanda Subject: Re: 580 Stars rd - Modern Age Home Builders Okay thank you. I did send them a copy and this morning asking if they will accept this for now. —Jennifer Jennifer Leeds Leeds Expediting Services 134 Sequoia Drive Coram, New York 11727 Office#631-509-4248 Cell#631-879-2684 Email-JenniferLeeds0255@gmail.com www.Leedsexpediting.com On Mon, Nov 23, 2020 at 10:17 AM Nunemaker,Amanda<Amanda.Nune maker@town.southold.ny.us>wrote: I do not know,you must contact the Zoning Board of Appeals Office to see if what you forwarded me is acceptable to meet their condition. From: Jennifer Leeds [mailto:jenniferleeds0255@gmail.com] Sent: Monday, November 23, 2020 10:08 AM To: Nunemaker, Amanda Subject: Re: 580 Stars rd - Modern Age Home Builders It could take months for the County to actually file the deed. He has to wait until then to start construction? Jennifer Leeds Leeds Expediting Services 134 Sequoia Drive Coram, New York 11727 Office#631-509-4248 Cell#631-879-2684 Email-JenniferLeeds0255@gmail.com www.Leedsexpediting.com On Mon, Nov 23, 2020 at 9:52 AM Nunemaker,Amanda<Amanda.Nunemaker@town.southold.ny.us>wrote: Thank you Jennifer. Make sure you forward the deed to the ZBA office as their decision has a condition in which a deed must be supplied. I'm assuming it has to be recorded but you should verify with them. Once they are satisfied with what you have submitted, please let me know so I can issue the permit. Thank you. From: Jennifer Leeds [mailto:jenniferleeds0255@gmail.com] Sent: Monday, November 23, 2020 9:37 AM To: Nunemaker,Amanda Subject: Re: 580 Stars rd - Modern Age Home Builders Amanda, Attached are all items you asked for last week to complete the application for 580 Stars Rd. Unfortunately it will be another couple of weeks until we receive the filed deed from the SC Clerk's office. As I'm sure you know there are major delays filing documents due to Covid restrictions on the public. Please let me know if I can provide you with anything additional. Thanks, Jennifer Jennifer Leeds Leeds Expediting Services 134 Sequoia Drive Coram, New York 11727 Office#631-509-4248 Cell#631-879-2684 Email-JenniferLeeds0255@gmaii.com www.Leedsexpediting.com i On Fri, Nov 20, 2020 at 11:55 AM Nunemaker,Amanda <Amanda.Nunemaker@town.southold.ny.us>wrote: We will let you know the fee once the permit has been written. From: Jennifer Leeds [maiito:jenniferleeds0255@gmail.com] Sent: Friday, November 20, 2020 11:42 AM To: Nunemaker, Amanda Subject: Re: 580 Stars rd - Modern Age Home Builders Thank you. Do I send the fee right away too? Jennifer Leeds Leeds Expediting Services 134 Sequoia Drive Coram, New York 11727 Office#631-509-4248 Cell#631-879-2684 Email-JenniferLeeds0255@gmaii.com www.Leedsexpediting.com On Fri, Nov 20,2020 at 11:31 AM Nunemaker,Amanda <Amanda.N u nemaker@town.southold.ny.us>wrote: Thank you. See the attached. Front: Jennifer Leeds [mailto:jenniferleeds0255@gmaii.com] Sent: Friday, November 20, 2020 9:21 AM To: Nunemaker, Amanda Subject: 580 Stars rd - Modern Age Home Builders Amanda, I can't find the form for the Cert.of Occp that you asked me to send you with the deed and updated RES check. Can you email me a copy? Attached is the updated RES check. Owner is getting a copy of the deed and I'll send everything together. Thanks, Jennifer Jennifer Leeds Leeds Expediting Services 134 Sequoia Drive Coram, New York 11727 Office#631-509-4248 Cell#631-879-2684 Email-JenniferLeeds0255@gmaii.com www.Leedsexpediting.com ATTENTION: This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. SURVEY OF PROPERTY LOT 1-MAP OF SOUNDCREST WOODS,SEC. 1 FILED:JUNE 9.1969-MAP NO.5315 SITUATE EAST MARION TOWN OF SOUTHOLD SUFFOLK COUNTY,N.Y. I TAX MAP NO.:1000031.00-04.00008.000 LOT AREA 20.451,8E S.F.(0.469 A.CRESI DATE SURVEYED:AUGUST 26,2020 rt.Q LANDN/F EKJO FAMILY 7RU51 z PROPOSED POOL:J .N.21.2021 Q RESIDENCE-WELL WATEFf � 0 N79°42'40"E LOT 2 204.06 4� -ELEVATIONS REFERTO NAVD88. CEDAR R.yY y Sf0.�fND. ' +25,„tit 3g. ,4aa llEe rno O DRIVE ;o � OF�.'CLLrGI MLS Fest ��” N O e�' �2 - 1 rca a<c4nnw ~ O SCALE: IINCI-.= 40 FEET � � 60.1' �V Jai;�'_._.__ ._� O U/ •� S P's_ r °�"g LI LOT 1 U 57.5'. Q cli OF New k - �' O H<.lY°�i / , Z pp O 2 +tea' !� u C, ! O SAWAW 1, AS PER CT1£% o ' $TN(EFIf0. a `ro1Oi£ W 205.00 S79'42'40"W 8 510-1. .0' WIDE PUBLIC NO' LANDIJ!F"IHOMASCORNELL O�Q � RGHT OF WAY r VALAANT LAND vm t 150'TO W ELL N - N83'18'40"E r ANG O SETH CECERE 2004. PROF SIONAL LANG SURVEYOR ren lvn ut:Nrfn. v •Lh0�£ O 7'AJG LAND SURVEYING PLLC LAND SURVEYING'&-PLANNING` 77 S.COLEMAN Rowe,CRKTEREACH,NY I-l720" (_ -:PHONE:,631..846.9973. _ =•-=-"- - i ='"EMAIL:_AJC24&6PTON LIN E.N ET POOL NOTES: 2020 RESIDENTIAL CODE OF NYS,SECTION R326 SWIMMING POOLS,SPAS AND HOT TUBS 1.POOL AND PROPERTY TO CONFORM TO 2020 NYS UNIFORM FIRE PREVENTION AND BUILDING CODE, TEMPORARY BARRIERS R326.4.1: TOWN OF SOUTHOLD CODE AND 2017 NATIONAL ELECTRIC CODE. 2.POOL SHALL CONFORM TO ANSI/APSP/ICC 5 STANDARDS R326.3.1. AN OUTDOOR SWIMMING POOL,SHALL BE SURROUNDED BY A TEMPORARY BARRIER DURING INSTALLATION OR CONSTRUCTION AND 3.SECTION R326.7 POOL ALARM REQUIRED. SHALL REMAIN IN PLACE UNTIL A PERMANENT BARRIER IN COMPLIANCE WITH SECTION R326.4.2 IS PROVIDED. 4.POOL SHALL COMPLY WITH BARRIER REQUIREMENTS SECTION R326.4. 1.THE TOP OF THE TEMPORARY BARRIER SHALL BE AT LEAST 48 INCHES(1219 MM)ABOVE GRADE MEASURED ON THE SIDE OF THE 3" TO 6" 5.POOL SHALL COMPLY WITH 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NYS SECTION BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. CLEARANCE R403.10: 2.REPLACEMENT BY A PERMANENT BARRIER. A TEMPORARY BARRIER SHALL BE REPLACED BY A COMPLYING PERMANENT BARRIER UNDERWATER BETWEEN POOL POOLS AND PERMANENT SPA ENERGY CONSUMPTION(MANDATORY). WITHIN EITHER OF THE FOLLOWING PERIODS: AND WALL SECTION R403.10.1 HEATERS A)90 DAYS OF THE DATE OF ISSUANCE OF THE BUILDING PERMIT FOR THE INSTALLATION OR CONSTRUCTION OF THE SWIMMING LIGHT (TYP.) SECTION R403.10.2 TIME SWITCHES POOL;OR SECTION R403.10.3 COVERS B)90 DAYS OF THE DATE OF COMMENCEMENT OF THE INSTALLATION OR CONSTRUCTION OF THE SWIMMING POOL. 6.REBAR SHALL BE 3 MIN.CLEAR TO EARTH. 7.LOCATION OF PROPOSED SWIMMING POOL AND POOL EQUIPMENT BY OTHERS AND SHALL COMPLY PERMANENT BARRIER R326.4.2: WITH ALL LOCAL ZONING REQUIREMENTS. 8.ALL DRAIN COVERS TO MEET ALL REQUIREMENTS OF THE VIRGINIA GRAEME BAKER(VGB)POOL AND 1.THE TOP OF THE BARRIER SHALL BE NO LESS THAN 48 INCHES(1219MM)ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER SPA SAFETY ACT. THAT FACES AWAY FROM THE SWIMMING POOL.THE VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM OF THE BARRIER 9.SLOPE PATIO SURFACE 1/4"PER FOOT AWAY FROM POOL. SHALL BE NOT GREATER THAN 2 INCHES(51 MM)MEASURED ON THE SIDE OF THE BARRIER THAT FACES AWAY FROM THE SWIMMING 10.BACKFILL MATERIAL TO BE FREE DRAINING GRANULAR MATERIAL(NO CLAY OR LARGE ROCKS). POOL. WHERE THE TOP OF THE POOL STRUCTURE IS ABOVE GRADE,THE BARRIER MAY BE AT GROUND LEVEL,OR MOUNTED ON TOP 11.SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/APSP/ICC 7. OF THE POOL STRUCTURE. WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE,THE BARRIER SHALL COMPLY WITH 12.ENTRAPMENT PROTECTION REQUIRED SECTION R326.5. SECTIONS R326.4.2.2 AND R326.4.2.3. 13.POOL WALLS ARE NOT DESIGNED FOR SURCHARGE LOADS EXERTED BY WHEEL LOADS WITHIN SIX(6) 2.SOLID BARRIERS WHICH DO NOT HAVE OPENINGS,SHALL NOT CONTAIN INDENTATIONS OR PROTRUSIONS EXCEPT FOR NORMAL 4' FEET OF POOL WALL FROM CONSTRUCTION EQUIPMENT OR ANY OTHER LOADING CONDITION IMPOSED CONSTRUCTION TOLERANCES AND TOOLED MASONRY JOINTS. ON THE POOL STRUCTURE BY EXISTING OR PROPOSED ADJACENT STRUCTURES. 3.WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE ^ 14.NO DIVING EQUIPMENT PERMITTED. HORIZONTAL MEMBERS IS LESS THAN 45 INCHES(1143 MM),THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE SWIMMING A A ` 15.POOL TO REMAIN PERMANENTLY FILLED. POOL SIDE OF THE FENCE. SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 1-3/4 INCHES(44 MM)IN WIDTH.WHERE 16.CONTRACTOR SHALL VERIFY SOIL BEARING LOADS PRIOR TO INSTALLATION OF POOL. THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS,SPACING WITHIN THE CUTOUTS SHALL NOT BE GREATER THAN 1-3/4 17.THIS PLAN IS FOR CONSTRUCTION ON PROPERTY AT 580 STARS ROAD,EAST MARION,N.Y.11939 INCHES(44 MM)IN WIDTH. ONLY. 4.WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE 18.REINFORCING STEEL SHALL BE INTERMEDIATE GRADE BILLET STEEL WITH A MINIMUM LAP OF 30 BAR HORIZONTAL MEMBERS IS 45 INCHES(1143 MM)OR MORE,SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 4 INCHES(102 DIAMETERS. MM).WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS,SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1- 3/4 INCHES(44 MM IN WIDTH. 5.MAXIMUM MESH SIZE FOR CHAIN LINK FENCES SHALL BE A 2-1/4-INCH(57MM)SQUARE UNLESS THE FENCE HAS SLATS FASTENED AT THE TOP OR THE BOTTOM WHICH REDUCE THE OPENINGS TO NOT MORE THAN 1-3/4 INCHES(44 MM). 221, 6.WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS,THE MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS PROPOSED GENERAL NOTES: SHALL BE NOT GREATER THAN 1-3/4 INCHES(44 MM). 7.GATES SHALL COMPLY WITH THE REQUIREMENTS OF SECTION R326.4.2.1 THROUGH R326.4.2.6 AND WITH THE FOLLOWING 20' VINYL SWIMMING POOL 12' CONTINUOUS 1. HM ENGINEERING,P.C.SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS, REQUIREMENTS: I CONCRETE TECHNIQUES OR PROCEDURES UTILIZED BY THE CONTRACTOR,NOR FOR THE SAFETY OF THE 7.1. ALL GATES SHALL BE SELF-CLOSING.IN ADDITION,IF THE GATE IS A PEDESTRIAN ACCESS GATE,THE GATE SHALL OPEN OUTWARD,800 S.F' SEE PUBLIC OR CONTRACTOR'S EMPLOYEES,OR FOR THE FAILURE OF THE CONTRACTOR TO CARRY AWAY FROM THE POOL. WALL ( OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7.2. ALL GATES SHALL BE SELF-LATCHING,WITH THE LATCH HANDLE LOCATED WITHIN THE ENCLOSURE(LE,ON THE POOL SIDE OF THE DETAIL THIS ENCLOSURE)AND AT LEAST 40 INCHES(1016 MM)ABOVE GRADE. IN ADDITION,IF THE LATCH HANDLE IS LOCATED LESS THAN 54 SHEET) 2. SELECT GRANULAR FILL/MATERIAL SHALL BE AS DEFINED IN THE REQUIREMENTS OF THE INCHES(1372 MM)FROM GRADE,THE LATCH HANDLE SHALL BE LOCATED AT LEAST 3 INCHES(76 MM)BELOW THE TOP OF THE GATE, MUNICIPAL AGENCY HAVING JURISDICTION AND AS A MINIMUM DEFINED IN SECTION 203 OF AND NEITHER THE GATE NOR THE BARRIER SHALL HAVE ANY OPENING GREATER THAN 0.5 INCH(12.7 MM)WITHIN 18 INCHES(457 N.Y.S.D.O.T.STANDARD SPECIFICATIONS,LATEST EDITION. MM)OF THE LATCH HANDLE. 7.3. ALL THE GATES SHALL BE SECURELY LOCKED WITH A KEY,COMBINATION OR OTHER CHILD PROOF LOCK SUFFICIENT TO PREVENT CORNER STEPS 3. COMPACTION SHALL CONFORM TO THE REQUIREMENTS OF THE MUNICIPAL AGENCY HAVING ACCESS TO THE SWIMMING POOL THROUGH SUCH GATE WHEN THE SWIMMING POOL IS NOT IN USE OR SUPERVISED. (VINYL OVER JURISDICTION AND AS A MINIMUM DEFINED IN SECTION 203 OF N.Y.S.D.O.T.STANDARD 8. A WALL OR WALLS OF A DWELLING MAY SERVE AS PART OF THE BARRIER,PROVIDED THATTHE WALL OR WALLS MEETTHE CONCRETE) LINE OF SPECIFICATIONS,LATEST EDITION. APPLICABLE BARRIER REQUIREMENTS OF SECTIONS R326.4.2.1 THROUGHT R326.4.2.6 AND ONE OF THE FOLLOWING CONDITIONS SHALL BE MET: COPING 4. ALL FILUBACKFILL SHALL BE SELECT GRANULAR MATERIAL,COMPACTED TO 95%MAXIMUM l.a. DOORS WITH DIRECT ACCESS TO THE POOL THROUGH THAT WALL SHALL BE EQUIPPED WITH AN ALARM WHICH PRODUCES AN / \ DENSITY AT OPTIMUM MOISTURE,AS DETERMINED BY MODIFIED PROCTOR TEST,UNLESS AUDIBLE WARNING WHEN THE DOOR AND/OR ITS SCREEN,IF PRESENT,ARE OPENED.THE ALARM SHALL BE LISTED IN ACCORDANCE 4' OTHERWISE NOTED. WITH UL 2017. THE AUDIBLE ALARM SHALL ACTIVATE WITHIN 7 SECONDS AND SOUND CONTINUOUSLY FOR A MINIMUM OF 30 SECONDS AFTER THE DOOR AND/OR ITS SCREEN,IF PRESENT,ARE OPENED AND BE CAPABLE OF BEING HEARD THROUGHOUTTHE 5. DEBRIS SHALL NOT BE BURIED ON THE SUBJECT SITE. ALL UNSUITABLE MATERIAL,SURPLUS HOUSE DURING NORMAL HOUSEHOLD ACTIVITIES. THE ALARM SHALL AUTOMATICALLY RESET UNDER ALL CONDITIONS. THE ALARM MATERIAL AND DEBRIS SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL,TOWN, SYSTEM SHALL BE EQUIPPED WITH A MANUAL MEANS,SUCH AS TOUCH PAD OR SWITCH,TO TEMPORARILY DEACTIVATE THE ALARM COUNTY,STATE AND FEDERAL LAWS AND APPLICABLE CODES. FOR A SINGLE OPENING. DEACTIVATION SHALL LAST FOR NOT MORE THAN 15 SECONDS; AND b.OPERABLE WINDOWS IN THE WALL OR WALLS USED AS A BARRIER SHALL HAVE A LATCHING DEVICE LOCATED NO LESS THAN 48 INCHES ABOVE THE FLOOR.OPENINGS IN OPERABLE WINDOWS SHALL NOT ALLOW A 4-INCH-DIAMETER SPHERE TO PASS THROUGH THE OPENING WHEN THE WINDOW IS IN ITS LARGEST OPENED POSITION;AND c.WHERE THE DWELLING IS WHOLLY CONTAINED WITHIN THE POOL BARRIER OR ENCLOSURE,ALARMS SHALL BE PROVIDED AT EVERY DOOR WITH DIRECT ACCESS TO THE POOL;OR 2. OTHER APPROVED MEANS OF PROTECTION,SUCH AS SELF-CLOSING DOORS WITH SELF-LATCHING DEVICES,SHALL BE ACCEPTABLE SO LONG AS THE DEGREE OF PROTECTION AFFORDED IS NOT LESS THAN THE PROTECTION AFFORDED BY ITEM 1 DESCRIBED ABOVE. 8.1 ALARM DEACTIVATION SWITCH LOCATION.WHERE AN ALARM IS PROVIDED,THE DEACTIVATION SWITCH SHALL BE LOCATED 54 40' INCHES OR MORE ABOVE THE THRESHOLD OF THE DOOR.IN DWELLINGS REQUIRED TO BE ACCESSIBLE UNITS,TYPE A UNITS,OR TYPE B UNITS,THE DEACTIVATION SWITCH SHALL BE LOCATED 48 INCHES ABOVE THE THRESHOLD OF THE DOOR. 42' TRACK FOR 9• WHERE AN ABOVE-GROUND POOL STRUCTURE IS USED AS A BARRIER,OR WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE,THE STRUCTURE SHALL BE DESIGNED AND CONSTRUCTED IN COMPLIANCE WITH ANSI/APSP/ICC 4 AND MEETTHE VINYL LINER APPLICABLE BARRIER REQUIRMENTS OF SECTIONS R326.4.2.1 THROUGH R326.4.2.8.WHERE THE MEANS OF ACCESS IS A LADDER OR STEPS,ONE OF THE FOLLOWING CONDITIONS SHALL BE MET: VINYL LINER 1 B ! I { I { { 9.1. THE LADDER OR STEPS SHALL BE CAPABLE OF BEING SECURED,LOCKED OR REMOVED TO PREVENT ACCESS.WHEN THE LADDER OR POOL PLAN NOTE: - FOAM PADDING -I I I ! STEPS ARE SECURED,LOCKED OR REMOVED,ANY OPENINGS CREATED SHALL NOT ALLOW THE PASSAGE OFA 4-INCH-DIAMETER THIS IS A NON DIVING POOL 4 f + SPHERE;OR e 3,500 PSI -! _ 9.2. THE LADDER OR STEPS SHALL BE SURROUNDED BY A BARRIER WHICH MEETS THE REQUIREMENTS OF SECTIONS R326.4.2.1 SCALE: 1/4 " = �-O�� CONCRETE ( { THROUGH R326.4.2.8. ENTRAPMENT PROTECTION R326.5: #4 REBAR TOP, MIDDLE&BOT. a 42" �_____ SUCTION OUTLETS SHALL BE DESIGNED TO PRODUCE CIRCULATION THROUGHOUTTHE POOLAND SPA. SINGLE-OUTLET SYSTEMS, a I _UNDISTURBED SUCH AS AUTOMATIC VACUUM CLEANER SYSTEMS,OR MULTIPLE SUCTION OUTLETS,WHETHER ISOLATED BY VALVES OR OTHERWISE, EARTH SHALL BE PROTECTED AGAINST USER ENTRAPMENT. __ _-I I I. 1.SUCTION OUTLETS MAYBE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF CPSC 15 USC 8003 AND ANSI/ 40, v - -- APSP/ICC 7,WHERE APPLICABLE. APPROVED AS NOTED 3'-4" - I__ s � _� SUCTION OUTLETS R326.6: DATE: B.P.# gm :T Ll� a i SUCTION OUTLETS SHALL BE DESIGNED TO PRODUCE CIRCULATION THROUGHOUTTHE POOL AND SPA. SINGLE-OUTLET SYSTEMS, SUCH AS AUTOMATIC VACUUM CLEANER SYSTEMS,OR MULTIPLE SUCTION OUTLETS,WHETHER ISOLATED BY VALVES OR OTHERWISE, i SHALL BE PROTECTED AGAINST USER ENTRAPMENT. FEE: E _ CONCRETE i - ( f 1.SUCTION OUTLETS MAYBE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/APSP/ICC 7. NOTIFY BUILDIN AiAT VIEW ACROSS CENTERLINE OF HOPPER i WALL (SEE - i I { I I I I ( , I , 1 2.POOL AND SPA SUCTION OUTLETS SHALL HAVE A COVER THAT CONFORMS TO ANSI/ASME A112.19.8,OR AN 18 INCH X 23 INCH 765-1802 8 AM TC, ?M FOR THE DETAIL THIS (457MM BY 584 MM)DRAIN GRATE OR LARGER,OR AN APPROVED CHANNEL DRAIN SYSTEM. -: - - __ __ ___, __ _, != SHEET) 3.POOL AND SPA SINGLE-OR MULTIPLE-OUTLET CIRCULATION SYSTEMS SHALL BE EQUIPPED WITH ATMOSPHERIC VACUUM RELIEF FOLLOWING I N - T i, ':�S: SHOULD GRATE COVERS LOCATED THERE IN BECOME MISSING OR BROKEN. THIS VACUUM RELIEF SYSTEM SHALL INCLUDE AT 1. FOUNDATION - TWO REQUIRED {_ j==-= ! _-'" - ' - 'I - $ ( i i- TYPICAL WALL DETAIL =�_ �-, _ �,. �--r�'' � ; �I._-� -I,i -� -�,i_ - ..._ i UD LEAST ONE APPROVED OR ENGINEERED METHOD OF THE TYPE SPECIFIED HEREIN,AS FOLLOWS: i _ _ __, - .. i ! `_'i -I I -- �. { !I_�I_; SCALE:3/4"= 1'-0" 1.SAFTEY VACUUM RELEASE SYSTEM CONFORMING TO ASME A112.19.17;OR FOR POURED COt�.�_RF'c 2.AN APPROVED GRAVITY DRAINAGE SYSTEM. 2. ROUGH FRAMiI �� PLUMBING (' 3 - -LL' 4.SINGLE OR MULTIPLE PUMP CIRCULATION SYSTEMS HAVE A MINIMUM OF TWO SUCTION OUTLETS OF THE APPROVED TYPE.A 3. INSULATIONUNDISTURBED EARTH -' -- MINIMUM HORIZONTAL OR VERTICAL DISTANCE OF 3 FEET SHALL SEPARATE THE OUTLETS.THESE SUCTION OUTLETS SHALL BE PIPED 4. FINAL - CONST '. MUST r- SO THAT WATER IS DRAWN THROUGH THEM SIMUTANIOULSY THROUGH A VACUUM RELIEF-PROTECTED LINETO THE PUMP OR BE COMPLGT_ " J. -- i-- I NOTES: PUMPS. i - - 5.WHERE PROVIDED,VACUUM OR PRESSURE CLEANER FITTING SHALL BE LOCATED IN AN ACCESSIBLE POSITION AT LEAST 6 INCHES ALL CONSTRUCTI'_:�, ALL MEET TEFF. - 1.WALLS SHALL BEAR ON UNDISTURBED SOIL REQUIREMENTS OF 1 h�.CODES 0'F NEN' 2 SAND BOTTOM _ !�_�! _� I-{I j 2.ALL CONCRETE SHALL BE PLACED ASA MONOLfTHIC POUR. AND NOT MORE THAN 12 INCHES BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR AS AN ATTACHMENT TO THE SKIMMER. YORK STATE. NOT RESPONSIBLE: FOR TAMPED & ROLLED 3.BACKFILL MATERIAL TO BE SAND,GRAVEL OR OTHER NON-EXPANSIVE DESIGN OR CONSTRUCTION ERRORS. MATERIAL SWIMMING POOL AND SPA ALARMS R326.7: 16' 14' 6' 4' APPLICABILITY.A SWIMMING POOL OR SPA INSTALLED,CONSTRUCTED OR SUBSTANTIALLY MODIFIED AFTER DECEMBER 14,2006, SHALL BE EQUIPPED WITH AN APPROVED POOL ALARM.POOL ALARMS SHALL COMPLY WITH ASTM F2208(STANDARDS SPECIFICATIONS FOR POOL ALARMS),AND SHALL BE INSTALLED,USED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THIS SECTION. ELECTRICAL EXCEPTIONS: 1.A HOT TUB OR SPA EQUIPPED WITH A SAFETY COVER WHICH COMPLIES WITH ASTM F1346. INSPECTION REQUIRED 1. A SWIMMING POOL(OTHER THAN A HOT TUB OR SPA)EQUIPPED WITH AN AUTOMATIC POWER SAFETY COVER WHICH COMPLIES SECTION A-A WITH ASTM F1346. POOL ALARMS SHALL COMPLY WITH ASTM F2208,AND SHALL BE INSTALLED,USED AND MAINTAINED IN ACCORDANCE WITH THE SCALE: 1/4 of _ 1 -011 MANUR326.7.1 MULTIPLE ALARMS.A POOL ALARM MUONS AND THIS ST CAPABLE OF DETECTING ENTRY INTO THE WATER AT ANY POINT ON THE NOTE: SURFACE OF THE SWIMMING POOL. IF NECESSARY TO PROVIDE DETECTION CAPABILITY AT EVERY POINT ON THE SURFACE OF THE ALL MANUFACTURED ITEMS AND CONSTRUCTION SHALL COMPLY WITH THE 2020 SWIMMING POOL,MORE THAN ONE POOL ALARM SHALL BE PROVIDED. RESIDEN"PIAL CODE OF NYS,INCLUDING THE SPECIFICATIONS IN SECTION R326. 1 1/2"TO WASTE R326.7.2 ALARM ACTIVATION. POOL ALARMS SHALL ACTIVATE UPON DETECTING ENTRY INTO THE WATER AND SHALL SOUND HAIR&LINT STRAINER POOLSIDE AND INSIDE THE DWELLING. PUMP R326.7.3 PROHIBITED ALARMS. THE USE OF PERSONAL IMMERSION ALARMS SHALL NOT BE CONSTRUED AS COMPLIANCE WITH THIS SECTION. FILTER AUTO SKIMMER COMPLY WITH ALL CODES OF OCCUPANCY OR NO. DATE DESCRIPTION BY CO NEW YORK STATE & TOWN CODES tPOOL OWNER/APPLICANT: AS REQUIRE D AND CONDITIONS OF USE IS UNLAWFIJI-- BACK MODERN AGE HOME BUILDERS PROPOSED SWIMMING POOL PLAN 580 WITHOUT CERTIF I" ~ EAST STARS ROAD FOR EAST MARION,N.Y.11939 580 STARS ROAD 4 -BOARD OF OCCUPANCYSITUATED AT CERTIFIED ONLY FOR EAST MARION 5��,,,;t �� i u n�STEES SCHEMATIC PIPING ARRANGEMENT CONSTRUCTION AT: NOT TO SCALE 580 STARS ROAD TOWN OF SOUTHOLD, SUFFOLK COUNTY, NEW YORK -NN.S.DEC EAST MARION,N.Y.11939 NOTE: S.C.T.M. DISTRICT 1000, SECTION 031, BLOCK 04, LOT 08 NO MAIN DRAINS ARE PROPOSED. ENCLOSE POOL TO CODE HILI ENGINEERING, P.C. RETAIN STORM WATER RUNE?FF UPON COMPLETION PURSUANT TO CHAPTER 236 BEFORE "WATER" P.O. BOX 914, EAST NORTHPORT, N.Y. 11731 OF THE TOWN CODE, PHONE(516)476-5392 FAX(631)980-7671 WWW.HMARNIKA@OPTONLINE.NET THESE PLANS,SPECIFICATIONS,&DESCRIPTION OF DESIGN INTENT ARE THE INSTRUMENT OF DEVICE AND PROVIDE -•/ PROPRIETARY INFORMATION EXCLUSIVE TO THE PROFESSIONAL SERVICES RENDERED FOR THE CLIENT LISTED ABOVE. THEY 1v_ d C `s, to DRAWN BY: HM PROJECT NO.: 20157 SHALL NOT BE REPRODUCED,ALTERED,OR TRANSFERRED IN ANY MANNER FOR THE SAME OR SIMILAR PROJECT WITHOUT I WRITTEN CONSENT OF THE ENGINEER. THEY SHALL REMAIN THE PROPRIETY PROPERTY OF THE HEREIN ENGINEER OF IFM PIES DESIGN PROFE SIO DATE: NOVEMBER 15,2020 DRAWING NO.: RECORD,WHETHER OR NOT WORK DESCRIBED WITHIN THIS DOCUMENT AND ATTACHMENT IS CARRIED TO COMPLETION. EDs ND SIGNATURE IN BLUE THIS WORK IS THE COPYRIGHT PROPERTY OF THE ENGINEER AND IS PROTECTED UNDER SECTION 102 OF THE COPYRIGHTACT, 17 U.S.C. ANY UNAUTHORIZED USE AND/OR REPRODUCTION OF THE DRAWINGS SHALL BE PROSECUTED UNDER THE FULL -101 EXTENT OF THE LAW. P.E.SEAL AND SIGNATURE SCALE: AS SHOWN SHEET NO.: OF 1 a�