Loading...
HomeMy WebLinkAbout47270-Z .rr-res- O�OSHFFOIk pG Town of Southold 3/24/2022 P.O.Box 1179 ' o - 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42943 Date: 3/24/2022 THIS CERTIFIES that the building SOLAR PANEL Location.of Property: 2645 Delmar Dr.,Laurel SCTM#: 473889 Sec/Block/Lot: 127.4-2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/3/2021 pursuant to which Building Permit No. 47270 dated 12/27/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Milian,Denis of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47270 2/8/2022 PLUMBERS CERTIFICATION DATED I Authorized Signature iso alp TOWN OF SOUTHOLD BUILDING DEPARTMENT x TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47270 Date: 12/27/2021 Permission is hereby granted to: Rugnetta, James 2645 Delmar Dr Laurel, NY 11948 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 2645 Delmar Dr., Laurel SCTM #473889 Sec/Block/Lot# 127.4-2 Pursuant to application dated 12/3/2021 and approved by the Building Inspector. To expire on 6/28/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 B ing Inspector oF SOUK,®l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlinCa-)town.southold.ny.us Southold,NY 11971-0959 OMNI BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Denis Milian Address: 2645 Delmar Dr city,Laurel st: NY zip: 11948 Building Permit#: 47270 Section: 127 Block: 4 Lot: 2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: SunRun Solar License No: 33878ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 2 Switches 4'LED Exit Fixtures Pump Other Equipment: 8.3kW Roof Mounted PV Solar Energy System w/ (2 1) LG395Q 1 C-A6 Modules, Solar Edge PV Rapid Shutdown, AC Disconnect Notes: Solar Inspector Signature: Date: February 8, 2022 S.Devlin-Cert Electrical Compliance Form o�aOF SOblyo ���J ti TOWN OF.-SOUTHOLD BUILDING DEPT. 765-1802 NS-PECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] -INSULATION/CAULKING ] -FRAMING /STRAPPING [ ] FINAL ] -FIREPLACE'& CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION = `' [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: < /0, i .DATE INSPECTOR _ �o�aOE SOUTyO� # # TOWN OF SOUTHOLD BUILDING DEPT. co,Kn, ' 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING FINAL 5O(C✓ [ ] FIREPLACE & CHIMNEY j ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION: [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE INSPECTOR _t � ' °� . 66i1P bEP�G DEPT . TODUt.i Or SOU.IHQL�, February 2, 2022. . trucrtu - s r Subject: Post lnstallation Approval:Letter : Job Number:-216R-645LLAM - Client: Denis Llamas _. Address: 2645 Delmar Dr, Laurel, NY,,11948 .. Attn.:To Whom It May Concern. The purpose of the-review was to verify the installation is in conformance with the.permitted plan set`and . .. . . . . that-any potential modifications from those plans;meet the intent of the permitted plan set The PV racking system's attachments'have been observed to be installed in conformance with the permitted plan set.The installation complies with:the code provisions listed:below. :202Q.NYS Code Books w%:2018 IRC/IBCIIEBC,;ASCE 7-16, NDS 2018 •Basic Wind Speed V 128 mph; Exposure: C q. .Ground Snow Load =25 psf Paul Zacher,P.E. NEIti y Professional Engineer K 2AC,y D,A T.916:9613960 x101 ws . I? email: aul @P.zse com ,:. e0,:.. , . . . 8 w xa�9 c� ..: .. . , . . . . � ,1365 - SSioNP� FIELD:]NSPECTIQJY;REP RT RATE CONTNINTS ►o FOUND41ON;(1ST ; No (A H ROUGH FRA MING:,&. y PLUMBING' • INSULATION pER STATE ENERGY CODE OfFINAL ADDITI03VAL G �1�IMENTS' 1p 90.. got tt - ,. 7f , • � H• 7 H. QgUFFQL��, TOWN OF SOUTHOLD BUILDING DEPARTMENT- Town Hall Annex-54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 o yob aa� Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowMngov .1� Date Received. . APPLICATION:FOR BUILDING PERMIT= For Office Use Only E. C. �I PERMIT NO. �_72,16 Building Inspector: DEC - : M1_ Applications and forms must be filled out in their entirety.Incomplete BUILDIPJG DEPT. applications will not be accepted. Where the Applicant is not the owner,-an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be-completed. Date: 12- OWNER(S) LOWNERS)OF PROPERTY: Name: // '� SCTM#1000-127.00-04.00-002.000 rw Project Address: _ Phone#: Email;. _ 3 l: l® 2-__. -_.7 57o ._: . '' -V( D -., -7ZoO8s..Lj o�C4l.eCA - Mailing Address: CONTACT PERSON: ; Name Cole.-Gartmayer _:_' Mailing Address: 1-77�Cantia ue Rock Rd Westbu NY 11590 : _ Phone#:.516-614-7:891 : . . Eman:LiPermits@sunrun.com DESIGN PROFESSIONAL. NFORMATION: Name: ..PauLZacher MailingAddr:ss:1478 Stone Point Dr. Ste 190 Roseville CA 95661=_r..._._ Phone#:916-961-3960 _ Emali:paul@pzse.com CONTRACTOR INFORMATION: Name:Sunrun-lnstallation Services Mailing Address: 177 cantia ue rock rd Westbu n 11590 = ^Ph6ne#:516614-7891 : : Email:LiPermits@sunrun.co:m: •; DESCRIPTION OF PROPOSED CONSTRUCTION ElNew Structure ❑Addition ❑Alteration:El Repair ElDemolition Estimated Cost of Project: = ❑OtherSolar $27.750.00,. . . .. . Will the.lot be re-graded? ❑Yes RNo Will excess fill be:removed from premises? ❑Yes R No ::: PROPERTY INFORMATION Existing use of property: Intended use of property: Dwel I n g Intended N o. Change----- Zone or use district in which premises is situated:. Are there any covenants and restrictions:with respect'to this property? E]Yesohlo IF YES, PROVIDE A COPY. Check Box After Reading:,"The owner/contractor/design professional is responsible for:all drainage and storm water issues as provided by. Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone' Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances&.Regulations,for the construction of buildings, .additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building,code, housing code and regulations and to admit authorized inspectors on-premises and in building(s)for necessary inspections.False'statements made herein are punishable as a Class A misdemeanor pursuant to.Section 210AS.of the New York State Penal Law. COIe Ga Application Submitted By(p 1 n • l. Lmayer BAuthorized Agent ❑Owner Signature of Applicant: ::. Dateqo : ::: STATE OF NEW YORK) SS: _. _. .. COUNTYOF Jyl ) C. being duly-sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, ... (S)he is the ...... . (Contractor,Agent,Corporate:Officer,etc. of said owner or owners, and is duly authorized to perform or have performed the said work and-to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and _.. that the work will be-performed in the manner set forth in the application file therewith. Sworn before me this - day of - . 20 _. . NP li'CCOLE GIORGETTI;: otary Puh!ic, State of hiew'York .. Nei: 01G16292933 Qualified in Siff-A.County PROPERTTOWNER AUTHORIZATION Commiss!on-Er, ire:: lore rfi�r 12, 70 (Where the applicant isnot the owner) I, ee2 residing at-: qf- .: .: wdl. . C�l 70:do hereby authorize - to apply on my behalf to the:Town of Southold Building Department for approval as d scribe' .herei . . . Owner's Signature pate e, NICOLE... .GIORGETTI Notary Fublio:_State of New York L:A G No. 011616292933 '� 1 � :Oualified in Suffolk_County Print Owner's Name 201 Comm issian.Expires November.12, 2 o�S�fF01.t BUILDING DEPARTMENT- Electrical Inspector �� yam► TOWN OF SOUTHOLD y z Town Hall Annex- 54375 Main Road - PO Box 1179 o • Southold, New York 11971-0959 y O� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr@..southoldtownny.gov —.seandCa)_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: suli 1ZU N So LAT-P, Electrician's Name: License No.: Elec. email: Elec. Phone No: ❑1 request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: Address: 2 6 LIE LMS R R - L— rz- E L-- Cross _Cross Street: Phone No.: Bldg.Permit#: 1 277 Q email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): -Go .- ' Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑NO Issued On Temp Information: (All information required) Service Size[-11 PhF—]3 Ph Size: A #Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 n2 H Frame 0 Pole Work done on Service? Y DN Additional Information: PAYMENT DUE WITH APPLICATION �.� � ; s � o � Sfr YORK NEW Workers' ers'. - - : .. CERTIFICATE OF -:.. STATE Compensation NYS WORKERS' COMPENSATION.INSURANCE COVERAGE Board, 1a.Legal Name.&Address of Insured use street address onl 1b.Business Telephone Number of Insured Sunrun Installation Services Inc. (415)946-7500 -225 Bush Street,Suite 1400 San Francisco,CA.94104 1c.NYS:Unemployment Insurance Employer Registration Number of Insured 50-86426 4 Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number.of Insured or Social Security certain locations in New York State,i.e.;a Wrap-Up Policy) Number:. : - 77-0471407 2.Name and Address of Entity Requesting Proof of Coverage: 3a.Name of Insurance Carrier (Entity Being.Usted as the Certificate Holder) ..AMERICAN ZURICH INSURANCE COMPANY. Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" Town Hall Annex Building 54375 Route 25 .. .. WC 6142876.00 P 0 Box 1179 Southold,NY 11971 - - : 3c.Policy effective period 10/01/2021: to 10/01/2022 3d.The Proprietor,Partners or Executive.Officers are Q..Included.(only check box if.all.partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in-box"3"insures the business.referenced above in box"1a"for workers' compensation under the New York.State Workers'Compensation Law.(To use this form, New York.(NY)must be listed under Item 3 on.the INFORMATION PAGE of the workers'compensation insurance policy): The Insurance.Carrier or its licensed.agent will send .. . . this Certificate of Insurance to-the entity listed,above as the certificate holder in box"2". The insurance carrier must notify.the above certificate holder and the Workers'Compensation Board within 10 days IF a policy.is canceled due to nonpayment of premiums:or within 30 days IF there.are reasons other than nonpayment of premiums that cancel the policy.or . eliminate the insured from the-coverage indicated on this Certificate.(These'notices may be sent by regular mail.)Otherwise,this Certificate is valid for one'year after this form is approved by the Insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued-as a-matter of information only and confers no rights upori'the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the.policy:fisted,nor does it confer any rights or responsibilities beyond those contained in the .referenced policy. This certificate may be used'as evidence of a Workers'Compensation contract of insurance only while:the:underlying policy is in effect. :Please Note: Upon cancellation of the workers'compensation policy indicated on this:formi if the business continues to be named on a permit,license or-contract issued by a certificate holder,the business must provide:that certificate holder_with a new Certificatwof Workers'Compensation Coverage or other authorized proof that the business is complying with the ..mandatory coverage requirements of the New York State Workers'Compensation Law.. .. . . :Under penalty of perjury,I certify that I am an authorized representative or licensed,agent of the insurance carrier referenced - above and that the named insured has the coverage as:depicted on this form.. Approved;by: Samantha Furlan (Print name of authorized representative or licensed agent of insurance carrier) Approved by: .. �'a.�rtarri�: 09 ZZ-21J2/ (Signature) (Date).:. Title: Underwriter Telephone Number of authorized representative or licensed agent of insurance carrier: (415)538-7125 Please Note::Only insurance carriers and their licensed:' nts are authorized to:issue Form C-105.2.'1' surance brokers are NOT authorized to issue it. . . C-105:2 (9-17) .. . - :www.wcb.ny.gov. �1 SUNRINC-02 TWANG AC®ROD DATE(MMIDDNYYY) CERTIFICATE OF LIABILITY INSURANCE 9i10i2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLYAND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the'poll6y(ies)must have ADDITIONAL INSURED provisions or be endorsed.. If SUBROGATION IS"WAIVED, subjectto the terms and conditions of the policy,certain policies may require an:endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER cANTACT Walter Tanner Alliant Insurance Services,Inc...: FAX aC,No,Ext): (AIC,No): 575 Market St Ste 3600 E-MAIL WaLter.Tanner alliant.com San'Francisco,CA 94105 ADD E INSURERS AFFORDING COVERAGE NAIC# INSURER A":Navigators Specialty Insurance Company 36056 INSURER': INSURERB:Zurich American Insurance Company 16535 SUnrun.Installation Services,Inc INSURER C:American Zurich Insurance Company 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER. THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED.BY THE POLICIES'DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE WVD POLICY NUMBER IMMIDI p11 LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2'000'000 CLAIMS-MADE OCCUR LA21CGL2303211C 10/1/2021 10/1/2022 .PREMISES TO RENTED 1,000,000 PREMISES Ea occurrence $ MED FRCP(Any oneperson) $ 5,000 PERSONAL&ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 2,000,000 X. :POLICY XX JECT F LOC PRODUCTS-COMPIOPAGG $ 2,000,000 X OTHER:Retention:$100,000 a .. . ..._ Per Project Agg 10,000,000 B AUTOMOBILE LIABILITY COMBINED.SINGLE LIMIT 2,000,000 Ea accident $ X ANY AUTO BAP614287700 1011%2021 10/1/2022 BODILY INJURY Perperson) $ OWNED SCHEDULED AUTOS ONLY AUTOS: BODILY INJURY Per accident $ HIRED NON-OWNED - AUTOS ONLY AUTOS ONLY PROPERTY DAMAGE . Peraccldent... X Cg ,Ped.: -:_: Call.:Not Covered Llablht Ded 250 000 3 X Y , UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ C WORKERS COMPENSATION X: STA UTE' ETH AND ROPRIEERS'LIRTNEY WC614287600 10/1/2021 10/1/2022. 1,000,000 ANY PROPRIETOR/PARTNERIEXECUTNE E.L.EACH ACCIDENT: $ OFFICER/MEMBER EXCLUDED' ® N I A (Mandatory In NF1) - E.L.DISEASE-EA EMPLOYE $ 1'000'000 If es,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE=POLICY LIMIT DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required). Workers'Compensation Policy WC614287600:Deductible:$1,000,000. Evidence of insurance 'CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE -THEREOF, NOTICE WILL BE DELIVERED IN :. Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS.. 53095 Route 25. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name:and logo are registered marks of ACORD NEw Workers' voR1 CERTIFICATE O.F.INSURANCE COVERAGE STATE. Compensation Board_ 'UNDER THE NYS DISABILITY BENEFITS LAW PART 1.. .To.be completed by Disability Benefits Carrier or Licensed Insurance Agent of that:Carrier 1a.LegalName&Address of Insured(use street address only) 1b.Business Telephone Number of Insured- 845-268-2595 Sunrun Installation Services Inc 595 Market Street,29th Floor 1c.NYS Unemployment Insurance Employer Registration Number of - San Francisco,CA 94105 Insured Work Location of Insured(Only required if coverage is specirically limited to certain locations in New York State,i.e.,a Wrap-Qp Policy) 1d.Federal Employer Identification Number of Insured or Social Security. . Number 15 Charlotte Ave - 77-0471407 Hicksville,NY 11801. 2.Name and-Address of Entity Requesting Proof of Coverage.- 3a.Name.of Instirarice Carrier .. (Entity Being Listed as the Certificate Holder) The Prudential Insurance Company Of.America own of Southold 3b:Policy Number of Entity Listed.in Box"1a" 54375 Route 25 CG-52$30-NY P.O.Box 1179 Southold,NY 11971 3c.Policy effective period 01101/2018 to 12/31/2020 1. 4.Policy covers: ® A.All of the employer's employees eligible under the New York Disability Benefits Law E] B.;Orily;the following class or classes of employer's employees:: ... Under penalty of perjgry,.I certify that I am an authorized representative or licensed agerit of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed January 26,2018 -By: -= = . .. (Signature of insurance camels authorized representative orNYS-Licensed Insurance Agent of that insurance carrier) Telephone Number 973-548-6389 Title Statutory Disability Coordinator-- IMPORTANT: If Box-74a"is checked,and this form:is signed by the insurance carriers authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate.is.COMPLETE.Mail it direct) tothe.certificate holder. Y --- If Box"4b"is checked,this.certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the.Disability Benefits Law.It must be mailed for completion-to.the Workers'Compensation Board,DB Plans Acceptance,Unit,328 State Street,-Schenectady,NY 12305.- PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box."4b''o f Part 1 has been checked) ..State-of New York. Workers'Compensation Board According to information.maintained bythe NYS Workers'Compensation Board,the aboye7 named employer has complied with the NYS.. . Disability Benefts Law with respect to all of his/her employees. Date Signed By Signature of NYS Workers'Compensation Board Employee) . .... Telephone Number Title Please Note:-Only insurance carriers licensed to write NYS disability benefits insurance.policies and NYS licensed insurance agents of . those insurance:carriers are authorized to issue Form DB-120.1. Insurance brokers- 'are NOT authorized to issue this form. DB-120.1 (0-15) �•>',`•"� s•;a.,9 �,.� /f '•,~ > i.,� /4'"' ,.,'_�"^.h.:?^� ,�.e r"' :'\ ,C-•+.Y-. .•:,.`. /-. ^"+3a7,*r.....;."� _•_^'-cam`r,...'.� ,s .:x 'Y,?'\ ...... �`' x .k... ..-aa�_-•e. •{up'+'' .�� r!`•yic q �..: � .,�•:���._,.. .Cl. ,1;•• 5.. tia 4110 ; -/„�`-a ... •_�`..! 1 - .... ti, .r r:..-.:.��__.-'.`' :1r t �-, -... i' t r ��i ,,r `�' tii+: ) ��J._,.�: i"'+ ta'"•�, a _�. -y. ..,.,•.,•-.-'.:s,:<�• y t .--„rm,.. �.{5• J ...�:.. :�.: � �L �iii°� ^�i ift+tsr.�'` "•T.-'''xF;`-P 2r1'� -�,.'l. �.fr°,Y� � �.�,,1 tF�r `4,•��{,ef fir?�v. �: r t1��:s �,�''• ..�„_. �;�., ,t°a`,-. :,.,•.� �..-:,`-.. :tom' .�- �,�`;`._'^;�.- r =� y.,<zy ..,... �ti,p � .r- •r,+: ff � ! ::+':.`. "S � .y..:+';, ,� - t t�.-'. ..�.,i. - '1, V1}�jy1.-:-- Y,i .w^..`�. }!�.c... .�. ,(, +r.>� :,�•” �r•i P.•'•.".3.�, t..:�;.�.>. _,,...1, r..-:,.'•.;/y. r r.. ♦ '',r_V .�.s's. �..K.a a.P{i ,�!'7, Tf'_ z. .'14, „ w .r 1 �.. F' 1,a+ _I'. v ,. i( ✓ �, r r t :=z .!. ! :� .✓ r7 13 c �r.r f ,t} ..,..' .,:,b!�,.�. G �. <... t r. .:,.�. -"• ,.'-`='s• � -} .+ �°�'' ... ,5, �•�q�J _:.�„• :a va':,.. ap/ : :;+ .+` t:.,.,,^ ``%(- :,: ,•.'r•1Tt, o "'R" L-dy',� -�� .t�.+ ,� Y.�r...;is ,.�',r x:,.. .� t r}• •+ {t .,�;%._...,. .ia�,.;,,,++•; :.ti\. '•'�a, ;,1''^' w"'.-} = •,y �,''-�. i `a�• J._ 5.�' ;Y%•s e=..: :. Yr _ t,;., va , �f •„�,__,... .L a..2'�� ..._.__t-."�'_...:'-,1.,�;?s.•.xa _.._r x. "`. •c.'�...,i�`'. :•� 'i..Z' u_..;c .C:`• .t]," 1+_�`. �c�... _v :a r. t' i _•.7�•. 't •rrS�.-�.r'r. h7.T^_."..1!"� 2. +._Mr• T'+ �?:Y_._.�-ar 'R 2— W ::7Y„ !• _-% � Suffolk nounDepartment of Labor, Lacens • YlS �" ��} 6 oto ume A a VETERANS NIEMORIAL HIGHWAY * HAUPPAUGE NEW YORK 11788 i� DATE ISSUED:' 10/1/2003 No. 33878-MEQ`'A-1`' , 1� ytivt E - :•:, ,u SUFFOLK COUNTYP 13— Master' Electrician Lic' ense Xvi'"iA" ,i rti�I,L 1, ayc+ti# is This is to.certify that SAIVIY A NlOUNAS :doing business as SUNRUN INSTALLATION SERVICES INC having given satisfactory evidence of competency,pis hereby licensed as MASTER ELECTRICIAN in accordance f with and subject to the provisions of applicable laws,rules and regulations of + �r f s, the County of Suffolk,State of New York. :t4 k , Additional Businesses cl+¢ler,ff'P�,1i ,•rh+.. : .NOT VALID;wITHQUT �F r4 ' TS DEPARTMENTAL SEAL AND A CURRENT ` ''n�a23A:1'�jr # W f{d �,4 ry t+ CONSUMER AFFAIRS: t N- ,,n''�' ID CARD.. (x }l< r Vi " k y,`;�.I; Acting Commissioner 7 i a Ar[itl,! ",SS.Tara., ,.r .:� - — _- '9':•i .. /y•aG.:. ..d.rr a jr. ..,:,,:i,., .'Sy>..-. .+:,.w.' T `•._...a d. E...}rr'y.�.w.:.. „y-'z. a..: C .ti Y:wM.. �< ...•r.Jaar:L.�.a:Ctaw:."t' t.. _c,. 'LY�'^t ^^-•s� ,!-•T z Y. =� .a •-+„k�u, :=� +? y`g- ,,'K"` a+.,,-x!" ta- Al� •t.i`: L -'r c•t4 .d..._.��.".+'s` y:- �.',tr...: swn,- •.Zy,rk•. ✓..,,,^ve'q :. .�j ...,., ;.p•4= ., r•°.c-, <t * ?s'.: r' �'r= ..p..,r .;v:.;�•.-,. .-v,,,i 1.. r ,1:r� ya.n• y. .tr _� .s'y.l _y.• {.. +# , ^,•:t,� P7, 4.. •`i '1..!_,.,: '•r-'"a-'fir P . b:.-:r yy''��� ^.< F::a?:- '"•{: ,_'�• iL.ti 3 y.. t.: 1"�,. t,.-T,-.... +" tt ,:a .�C• ..tom :,7. 'Pl• .. ,t d+ii ;1,V' .+1 :`^ t;.:i.•Si "x,` 'R <`' � ,i. c ,, .T.x.:.1- isa:-_ f� `.�. ,J: Veit'! `+:�v.�,� .J J.••., ! w•:{� z i y� •�.•t. (' 'i-°'� •.r. }" 1.'4 .:� �}�z �?l:•:+../ ��; w�.S !. F a�� �1�>'�0.1 1.�.+. :::".•,-, vrt".,,•:4: `ISr..p..:��,: .1..`w .n ���.�,x.s6••� �,`.,'4�,sS =��� .,,• qxp .;�:.L•_c�.:.�1;:,,.•.,_ +{�.,`t�t _lrr.}x g ..• .;rS �?w'-' Y� r'I rtl y.� •e✓'. .� �J t.u;,;•-�?.�f a.`i,,� Vis.^:^"f ate: r.-t •-C..c'.- "ay '» 1 .r+;•.•,^- ;,+,,',x"..r•a+;,'r.v.t.,r.y4A; tt�.{aa.r-+.,r.!.a:....-.Y ri;?�..w^-� _<...;,'�..,•:+...-�,:.V.t�+•,k.-_t':,.��rk•,,»-.:a��-_'r^..___^•:+s:.•.-Y.;,r..„.atr:...+s�t�canr�rC,,pS.•:_a,.'��=='•s....._.:—'i•s,yx�'�^'.^c,.'..I•,.,.r>{f;3 0 1l}?�.r;.-F.,+�.<.�,C ty,>r;.-.,•.,`,.r.....-:,:.r,.$._,:.�"4v_`. v l--"•'ss e'•�;'k,3...,I.eF.'.e'•;t"`^�y ti •'�'..w'.'.,'.�at" tz,1!,( r7+t 9 i��,.:�'dt•v��Sj rs .+,.,/..,,F'__-�Ct'.`;`«'�:;a,'..'a!•r'r tt{t�1�t�,af'.it{. :Y'">;' ?_tt-�"..._-._-':.\:a,Z.rr_.•x,,.t:-..,.^_{. ?tt;.Pf1�wr:,•t y7 1`.H�-`•`••;ra'-.T,�'n•�,--'-'-�:.-"„"'c.•.�`-=;•;�S rR!�Y�ti+P�'�tc..•^..\t.., r � �EET • STR� 9Z� � d w 0 x ro !v C> 20 - D �n t- d �►: 130.0 Sk 1� 023'40 ILA N 1 q . � I .ter i It 4 rn -7- 60.00 C cJ NorE= \ •=NONI/AIENT 08DIVISION APAP F/LEO IN THE OFF/CE OF TIIE CLERK OFSQFFOLK couvrY ON JUNE?Z,,19?0 AS ANAP NO.=54496. REVISIONS YOUNG 1& YOUNG APR.9,1972 400 OSTRANDER AVENUE, RIVERHEAD, NEW;YORK MAY 1,1972 ALDEN W YOUNG HOWARD W.YOUNG JUNE 19,1972 rROP5t51ONAL[NOIN;ttll AND LAND®URV[YOR LINAUIHORIT.Id ALTI4AIION 01 ADDITION LAND•URV[YOR.N.Y,S.LIC.NO.1£545 N.Y.S.LIC.NO.45552 f0 THIS SURVIY 5 A VIOLATION DI SECTION 7209 OF THE NEW YORK STATt SURVEY FOR: EDUCATION LAW. CONES,a THIS SURVEY MAD NOT NAkING S P.A. ENTERPRISES, INC. 181 LAND SVkVFYOk'S INKED SIAL 01 1BEA VALID RUT COPY. SHAH NPTI N CUnSlUlklU 100 N A LOT NO./9, ''LAUREL COUNTRY PS�i HIS GUARANTEIS INIWATID HEMON SHAH AVN ON:Y TO TH,PERSON fOR W/IUM h, sura• AT GUARA YEf�E;TW3. !S RRIIARID.AND Or. !.HALL w IH. LAUREL GOUT 'f`�GA L3S;SANK• LINDTITU CO Ir 5111 GOVlRIL"fNIAI A.e.•.�l GECU TY 1. !OUARANT CO. To TTG LSZGIV1+01.LIIIIL A n•v�.,Arl TOWN OR SMITHO,^ ��� TO THF ASSIGI7lE Ot TNt lk:.uw. a,S❑ SMITHOLD TUTION GUAAMAILS AAI NUI I;A;LIIA •. - _ t0 BY WNIY\ SUFFOLK CO., N.Y. v...•.' =�*�•1=� ,t,:o�: SCALE: /n r 40 r DATE: FEB.18, 972 dy0h°. I� E C E � V nn E g DEC 0 .3 2021 November 23,2021 _i Astra v.1.59 PZE CAT COA Subject:Structural Certification for Proposed Residential Solar Installation. ra Job Number:216R-645LLAM;Rev A5 Client:Denis Llamas Address:2645 Delmar Dr,Laurel,NY, 11948 L Attn:To Whom It May Concern b� c�Owl Afield observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun.Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: •2020 NYS Code Books w/2018 IRC/IBC/IEBC,7-16 ASCE&2018 NDS •Basic Wind Speed V= 128 mph, Exposure C •Ground Snow Load=25 psf Based on this evaluation,I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summa Hardware Check Includes Uplift Check on Attachments/Fastener,Structure Check Considers Main Structure Orientation Attachment Spacing/Cantilever Configuration GoverniDCRng Result Landscape 64/25 Staggered 54% Pass AR-01 Portrait 48/19 Staggered 60% Pass Roofing Material Pitch Structure Check Corii 21' Pass Paul zacher,P.E. NEW YORK STATE & TOWN CODES Professional Engineer AS REQUIRED AND CONDITIONS OF T: 916.961.3960 x 101 email: pawl@pzse.com S/OUT�H� TOWN ZBA SvrJrrlLY- A APPROV D AS NOTED S USTE SBOARD �K. ZAC 0,p �f F DATE: a IB.P.# ��11� N YN Y cam_ FEE: B1': w NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE XP�9f365'� FOLLOWING INSPECTIONS: OCCUPANCY OR AROFESS1 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE USE IS UNLAWFUL 2. ROUGH - FRAMING & PLUMBING 3. INSULATION WITHOUT CERTIFIC-' ELECTRICAL. 4. FINAL - CONSTRUCTION MUST 'NSPECTION REQUIRED BE COMPLETE FOR C.O. OF OCCUPANC" ALL CONSTRUCT!CN SHALL MEET THE REQUIREMENTS OF THE CODEUM4t@'oint Dr.suite 190,Roseville,CA,95661 I P (916)961-3960 YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:8295W DC,6000W AC •ALL WORK SHALL COMPLY WITH 2020 NYS Code Books w/2018 IRC/IBC/IEBC, SOLAR MODULES •MODULES:(21)LG ELECTRONICS:LG395Q1C-A6 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCE PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE6000H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. PV-3.0 LAYOUT •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. PV-4.0 ELECTRICAL RAPID SHUTDOWN:(21)APSMART RSD-S-PLC ROOFTOP ❑ SNR MOUNT PV-5.0 SIGNAGE MODULE LEVEL RAPID SHUTDOWN DEVICE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT 8 SKIRT GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER ® CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. Q SUNRUN METER ATTIC VENT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. SM 0 FLUSH ATTIC VENT SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE IIPM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. 0 PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALLINV INVERTER(S) 0 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) of NE SATELLITE DISH K'y ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. �K.ZACy�P� DC DC DISCONNECT(S) ® FIRE SETBACKS 11.29 AMPS MODULE SHORT CIRCUIT CURRENT. _ w w 17.64 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(a)&690.8(b)). CB IQ COMBINER BOX , HARDSCAPE v ! 136 F_—1 INTERIOR EQUIPMENT —PL— PROPERTY LINE AROFESSIONP L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION 00825-ME DC DIRECT CURRENT (E) EXISTING sw0 E.YE.�cxsw� „ao, ESS ENERGY STORAGE SYSTEM v.xes.xee 0"'g,"" 14Y 11948, "" EXT EXTERIOR _ INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC DENIS LLAMAS Q MSP MAIN SERVICE PANEL 2645 DELMAR OR,LAUREL,NY, (N) NEW 11948 NTS NOT TO SCALE TEL.(631)902-7506 OC ON CENTER APNrrMK#:APN: PRE-FAB PRE-FABRICATED 100D-127-00-04-00-002-000 PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: IP2ws---D, RSD RAPID SHUTDOWN DEVICE 216R-045LLAM LaurN. TL TRANSFORMERLESS DESIGNER: (415)580-0920 ex3 `��.• V P VOLTS TYPICAL JASON BARRY f W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A5 11/24/2021 PAGE PV-1.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:25 PSF WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 13'-0" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 1'-7" STAGGERED 128 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREWS: 5/16":2.5"MIN EMBEDMENT S.S. DI-AR-01-SCALE:3/16"=1'-0" LAG SCREWS: PITCH:21' 6/16":2.6"MIN EMBEDMENT AZIM:240° STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIA STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED I I TO BE ADDED AND OVERHAN REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: E3 B ••ALLOWABLE ATTACHMENT O SPACING INDICATED ON PLANS TO BE REDUCED BY E3 E3 7, E3 E3 E3 50% •• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE t-5'-4'TYP—t O 1/5TH OF ALLOWABLE 13'-10'. ATTACHMENT SPACING E3 B 14'-5° INDICATED ON PLANS 6'_11"T-6" B B E3 B E I B s u n r u n T' 00825-ME { 8'-7" 34'-7" 21,_5" F„o�em.sa.sa•6 FNtl6.6•l.ZOt3 CUSTOMER RESIDENCE: DENIS LLAMAS 2645 DELMAR OR,LAUREL,NY, 11948 TEL.(631)902-7506 APN/TMK•:APN: 1000-127-00-04-00-002-000 PROJECT NUMBER: OF NE/y 216R-045LLAM K.Z'(Cyy0 DESIGNER: (415)580-6920 ex3 * F'P* JASON BARRY Lu SHEET LAYOUT OFFSSIONP� REV:A5 11/24/2021 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE OMETER#: M PSEGLI98357341 ACCOUNT NO.#: UTILITY 9692556115 GRID 1 EXISTING / 200A MAIN l BREAKER J SOLAREDGE TECHNOLOGIES: EXISTING SE6000H-US WITH REVENUE i� 200A GRADE METERING(PN MAIN (N)LOCKABLE SE6000H-USS3),6000 WATT BLADE TYPE INVERTER FACILITY PANEL AC DISCONNECT 6000 WATT INVERTER JUNCTION BOX PV MODULES LOADS 3 3 2 OR EQUIVALENT 1LG ELECTRONICS:LG395Q1C-A6 s // (21)MODULES off.--o / (1)STRING OF(11)MODULES --- `i' (1)STRING OF(10)MODULES (N)35A F `iiw SQUARE D LOAD RATED DC L(21)APSMART RSDS-PLC MODULE PV BREAKER AT DU222RB DISCONNECT WITH AFCI, LEVEL RAPID SHUTDOWN DEVICES OPPOSITE END 3R,60A,2P APSMART TRANSMITTER OF BUSBAR 120/240VAC CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER s u n r u n 2 1"PVC OR EQUIV. (4)10 AWG THHNrrHWN-2 NONE (1)10 AWG THHN/THWN-2 3 1"PVC OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 00825-ME ,s cww�ons�vE,HCKsvx�rry neo, nor.-eos.sas.sas� F- CUSTOMER CUSTOMER RESIDENCE: DENIS LLAMAS 2645 DELMAR DR,LAUREL,NY, 11948 TEL.(631)902-7506 MODULE CHARACTERISTICS APNTMK#:APN: LG ELECTRONICS:LG395Q1C-A6: 395 W 1000-127-00-0"0-002-000 OPEN CIRCUIT VOLTAGE: 43.6 V PROJECT NUMBER: MAX POWER VOLTAGE: 37 V 216R-645LLAM SHORT CIRCUIT CURRENT: 11.29 A DESIGNER: (415)5BM920 ex3 SYSTEM CHARACTERISTICS-INVERTERI JASON BARRY SYSTEM SIZE: 8295 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A5 11/24/2021 SYSTEM OPERATING CURRENT: 21.83 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 QI. WARNING &WARNING INVERTERI NOTES AND SPECIFICATIONS: • • •LTAIC • DISCONNECT • •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM IF REQUESTED BY THE LIOCAL FIC ATHRJUCTIONS ARE REQUIRED BY SECTION 890,OR COMBINER PANELMAXIMUM SYSTEM VOLTAGE: 460 • •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD DO NOT ADD LOADS MAXIMUM CIRCUIT CURRENT: 30 1 WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED INMETHOD AND SHALL NOT BE HAND WRITTEN. LABEL LOCATION: 1• •F THE CHARGE THE OPEN POSITION PHOTOVOLTAIC AC COMBINER QF •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT APPLICABLE). CONTROLLER••DC-TO-DC C• 1 N/A ADC INVOLVED. LABEL LOCATION: PER CODE(S):CEC 2019:705.12(B)(2)(3)(c), •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERCOMBINER AC (IF APPLICABLE). CT(S),AC NEC 2017:705.12(B)(2)(3)(c) LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. COMBINER PANEL(IF APPLICABLE). INVERTER(S),DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):CEC 2019:690.13(B),NEC PER CODE(S):NEC 2017:690.53 2017:690.13(B) &WARNING &WARNING DUAL POWER SUPPLY POWER SOURCE OUTPUT CONNECTION SOURCES:UTILITY GRID . • • ' . DO NOT RELOCATE THIS AND PV SOLAR ELECTRIC OVERCURRENT DEVICE SYSTEM LABEL LOCATION: LABEL LOCATION: EQUIPPED ADJACENT TO PV BREAKER OF UTILITY SERVICE METER AND MAIN APPLICABLE). SERVICE PANEL. PER CODE(S):CEC 2019: PER CODE(S):CEC 2019:705.12(B)(3),NEC 705.12(B)(2(3)(b),NEC 2017: 2017:7D5.12(B)(3) 05 2M)(2)3)b) RAPID SHUTDOWN LABEL LOCATION: 7- R • PV SYSTEM UTILITY SERVICE ENTRANCE/METER,INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ.OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S):CEC 2016:690.12,NEC 2014:690.12,NEC 690.56,IFC 2012:605.11.1 LABEL LOCATION: INSTALLED WITHIN 3.OF RAPID SHUT DOWN SWITCH PER CODE(S):CEC 2019:090.56(C)(3),NEC 2017:.3,CF50(C)(3),201 IFC 4.5.3 805.11.1,IFC 2018: s u n r u n 1204.5,3,CFC 2019:1204.5.3 BUILDING SUPPLIED BY UTILITY 4" GRID AND PHOTOVOLTAIC SYSTEM SOLAR PV SYSTEM EQUIPPED 00825-ME ■ • • • WITH RAPID SHUTDOWN ® a�z�zo== ■• ■ • ■ CUSTOMER RESIDENCE: DENIS LLAMAS LABEL LOCATION: 2645 DELMAR DR,LAUREL,NY. INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, 11948 AT EACH TURN,ABOVE AND BELOW PENETRATIONS, 3„ TURN RAPID SHUTDOWN ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SWfTCH TO THE"OFF" TEL.(631)902-7506 APN/TMK#:APN: PER CODE(S):CEC(3),6 0.31( )(4)I,890.31 12(G)(4), POSMON TO SHUT DOWN w o<r,e�s 1000-127-00-04-00-002-000 NEC 2017:880.31(G)(3),890.31(G)(4)IFC 2012: 605.11.1.4 PV SYSTEM AND REDUCE SHOCK HAZARD IN THE PROJECT NUMBERPHOTOVOLTAIC AC DISCONNECT : ARRAY 216R-645LLAM •, �� DESIGNER: (415)58D-6920 ex3 NOMINAL OPERATING AC VOLTAGE: 240 VAC L PV SYSTEM JASON BARRY DISCONNECT LABEL LOCATION: LABEL-LOCATION., SHEET AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE LABEL LOCATION: SIGNAGE POINT OF INTERCONNECTION INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):CEC 2019:690.54,NEC 2017:690.54 ARE CONNECTED. (PER CODE:NEC890.56(B),NEC705.10,225.37,230.2(E)) PER CODE(S):CEC 2019:690.56(C)(1)(a),NEC 2017: REV:A5 11/24/2021 690.56(C)(1)(a) PAGE PV-5.0 (OLG Life's Good mom ■ N ■■ LG NeON" R �• LG NeON°R is new powerful product with global top level performance.Applied new cell structure without electrodes 60 cell on the front,LG NeON°R maximized the utilization of light and enhanced its reliability.LG NeON®R demonstrates LG'spVE V` �sCc 5 3 efforts to increase customer's values beyond efficiency.It features enhanced warranty,durability,performance under real environment,and aesthetic design suitable for roofs. Q b. Enhanced Warranty GlIt High Power Output LG now offer 25 years product warranty to accommodate The LG NeON°R has been designed to performance warranty as well.LG NeONO R has an significantly enhance its output making it efficient enhanced performance warranty.After 25 years,LG even in limited space. NeON°R is guaranteed at least 87.0%of initial performance. Aesthetic Roof ® Outstanding Durability LG NEON®R has been designed with aesthetics in With its newly reinforced frame design,LG mind:no electrode on the front that makes new NeON®R can endure a front load up to 6000 Pa, product more aesthetic.LG NEW R can increase and a rear load up to 5400 Pa. the value of a property with its modern design. � Better Performance on a Sunny Day Near Zero LID(Light Induced Degradation) LG NeONO R now performs better on a sunny The n-type cells used in LG NEW R have L days thanks to its improved temperature coefficient. almost no boron,which may cause the initial performance degradation,leading to less LID. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry.We successfully released first Mono X®series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,NeONTm(previously known as Mono X®NeON)&2015 NeON2 with CELLO technology won"Intersolar Award",which proved LG is the leader of innovation in the industry. LG NeON® R MEMM Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Module 350 Cell Vendor LG Maximum Power(Pmax) 350 Cell Type Monocrystalline/N-type MPP Voltage(Vmpp) 36.1 Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) 9.70 Dimensions(L x W x H) 1700 x 1016 x 40 mm Open Circuit Voltage(Voc) 42.7 66.93 x 40.0 x 1.57 inch Short Circuit Current(Isc) 10.77 Front Load 6,0001'a/125 psf Module Efficiency 20.3 Rear Load 5,400Pa/113 psf Operating Temperature -40-+90 Weight 18.5 kg/40.79 Ib Maximum System Voltage 1000 Connector Type MC4 Maximum Series Fuse Rating 20 Junction Box IP68 with 3 Bypass Diodes Power Tolerance(%) 0-+3 Length of Cables 1000 mm x 2 ea :STC(Standard Test Condition)Irradiance 1,000 W/m2,Ambient Temperature 25'C,AM 1 5 Glass High Transmission Tempered Glass The nameplate power output is measured and determined by LG Electronics at,ts sole and absolute discretion Frame Anodized Aluminium iiThe typical change in module efficiency at 200 W/m'in relation to 1000 W/m'is-2.0%. Electrical Properties(NOCT*) Certifications and Warranty Module 350 Certifications IEC 61215,IEC 61730-1/-2 Maximum Power(Pmax) 264 UL 1703 MPP Voltage(Vmpp) 36.0 IEC 61701(Salt mist corrosion test) MPP Current(Impp) 7.32 IEC 62716(Ammonia corrosion test) Open Circuit Voltage(Voc) 40.1 ISO 9001 Short Circuit Current(Isc) 8.67 Module Fire Performance(USA) Type 1 NOCT(Nominal Operating Cell Temperature)Irradiance 800 W/m2,ambient temperature 20'C,wind speed 1 m/s Fire Resistance Class(CANADA) Class C(ULC/ORD C1703) Product Warranty 25 years Output Warranty of Pmax Linear warranty** Dimensions(mm/in) *',)First 5 yea rs 95%2)After Sth year 04%annual degradation,3)25 years 870% Temperature Characteristics NOCT 44 t 3°C Pmpp -0.30%/oC Voc -0.24%/`C Isc 0.04%/oC Characteristic Curves Q 12001 1000 Soo 600 ue, qna.R.•1 400 -- 200 volrage Iv) 000 500 1000 1500 2000 2500 3000 3500 40.00 4500 ? e 140 120 ........... ........... ............ -..---..._.......-.. E Isc a 100 - _...._. _.__.......__._-.._-_.__. ti80 ................ ......................... ........-.- --------._.........p. .................................................................................................. 40 ..................................................................................................... 20 .................................. ............ -.----.-- - ..........-... --.. B 0 Temperature('C) -40 -25 o u so 25 90 *The distance between the center of the mounting/grounding holes ® L^ North America Solar Business Team Product specifications are subject to change without notice. "qa G LG Electronics U.S.A.lnc DS-T1-72-W-G-P-EN-60630 Life's Good Sylvan Ave,Englewood Cliffs,NJ 07632 y�' Copyright©2017 LG Electronics.All rights reserved. Innovation for a Better Life �� Contact Ig.solar@Ige.com 01/01/2017 www.l solarusacom vtl�' ARRAYI TRUE I MAG PV AREA SITE PLAN-SCALE=3/64"=1' PITCH AZIM R-01 AZIM (SOFT) ® A 21° 240' 252' 409.6 ACCESS ROOF O a g �•J \ (E)FENCE V/ \ g OF NEh o (E)RESIDENCE V K.Z4y0 (E)SHED y ter'? w fi o r w (N)ARAR-01 4 ROSSICNP L sunrun G CESS`OF 00825-ME (E)GATE �MP CUSTOMER RESIDENCE: DENIS LLAMAS AC 2645 DELMAR DR,LAUREL,NY, P SE 0 INV 11948 / TEL.(631) :APN:06 APNRMK#:APN: C1 1000-127-00-04-00-002-000 P' PROJECT NUMBER: 216R-645LLAM DESIGNER: (415)580-0920 ex3 \ JASON BARRY SHEET SITE PLAN NOTE:ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED ON EACH MODULE PER NEC 690.12 REV:A5 11/24/2021 PAGE PV-2.0 solar=@e • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/ SE5000H-US/ SE6000H-US/SE760OH-US/ SE10000H-US/ SE1140OH-US solar-�-: ,HD solar, [' . HD �pv afer 1 -25 ?na a a w e 6� • • • • H 0 e e 0 Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring IIIIIIIIIII', Outdoor and indoor installation wave Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us so I a r ' • • Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/ SE380OH-US/ SE5000H-US/ SE6000H-US/ SE760OH-US/ SE10000H-US/ SE1140OH-US SE3000H-US I SE380OH-US SE50001-1-US E6000H-US SE7600H-US E10000H-US SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA 3300,a(1208V 5000 @,208V_ ......... ........_...... .... ........ Max.AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA .3300.@,208V.! ............... .5000. ................ ................. ................. ........... AC Output Voltage Min.-Nom.-Max. Vac X383,-208 2291........................... ............... ................ ................ ............I.... ..I............. . ................ ................. ........... AC Output Voltage Min.-Nom.-Max. . 1/ 1/ ,/ ✓ Vac ..Q 1 1,7 240-2641........................... ................ ....I........I.. ........I....... ................. . ............... ................. ................. ........... AC Frequency(Nominal)................ ........I...... . 59:3.:fi0--�:5`t�............... ................. ................. ....H?..... .. ......... Maximum Continuous Output Current 16 24 A 208V..................................I.... ................ ................ ................ ................. ................ ................. ................. ........... Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A G°�240V.................................... ................ ................ ................ ................. ................ ................. ................. ........... GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Cnfigurable Thresholds ountry Co INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W..... Maximum DC Power....208 V.............. ........-........ .....5100..... ................ .....7750...... .......:.. _ Transformer-less,Ungrounded ....... Yes ................................................................................................................. ........... Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 .._..,,400 Vdc .............. ........... Maximum Input Current 208V - 9 13 5 I...... I :........I..... I ... ........ MaximuminputCurrent@240V 8.5 10,5 13.5...., ..,,165 20 27 30,5 „Adc Max.Input Short Circuit Current 45 Adc ......... ................... ..... ...... ......... ......... ... . ..... Reverse-Polarity Protection ... Yes ..................... ........... Ground-Fault Isolation Detection 600koSensitivity .. ......6........ .... ..Maximum Inverter Efficiency.............. ......99.......I................. .... ..... .. ..................99:?....................... .......................... ....%..... ........................... CEC Weighted Efficiency. ..........................................................99... ........... Nighttime Power Consu .....mption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,2igBee(optional),Cellular(optional) Revenue Grade.Data_ANSI.C12.2020... Optional!?)............. Rapid Shutdown-NEC 2014 and 17 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety. UL1741,UL3741 SA,UL36998,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule i4(HI) .......................................... .... ........... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range ............................3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG . • •,, . DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2 strings/14-6 AWG 3/4"minimum/1-3 strings/ AWG IW8e......I..... . . .14-6 AWG............ ........... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174m/mm 21.3 x 14.6 x 7.3/540 x 370 X 185 .......................................... ................................. .............I... ......I.............. ............. ........... eight with Safety Switch 22/10 25.1 11.4 26.2 11.9 38.8/17.6 Ib .............I............... ................................. .......l........ ................(................ ..... ........ ................... ....(.k$.. Noise <25 <50 dBA Cooling Natural Convection Natural convection ... . . ... Operating Temperature Range -13 to+140/-25 to+60(')(-40'F/-40'C option)(°).... 'F/'C Protection Rating NEMA 3R Inverter with y Safet Switch) ( Ii)For other regional settings please contact SolarEdge support Revenue grade inverter P/N:SEp H-USOOONNC2 is)For power de-rating information refer to:https://www.solaredge.mm/sites/default/files/se-temperature-derating-note-na.pdf (•)-40 version P/N:SE)oocxH-US000NNU4 rnf& RoHS 0SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE, OPTIMIZED B Snap rack- Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- In" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. 40 Appealing design with built-in aesthetics • No grounding lugs required for modules 40 All bonding hardware is fully integrated 40 Rail splices bond rails together, no rail --_—+ jumpers required 0 No drilling of rail or reaching for other tools required • Class A Fire Rating for Type 1 and 2 modules System Features Include Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling PL Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources Design snapnrack.com/configurator Where to Buy snapnrack.com/where-to-buy Snap rack- Solar Mounting Solutions Stainless Bolt with Stainless Steel Bonding Splice Standard Rail Split-Lock Washer Bolt with Split- Insert 015-09816 Lock Washer Bonding Adjustable End Clamp Top Bonding Splice Mid Clamp - - Base Bonding Bonding Adjustable Bonding Channel Nut End Clamp Bottom Channel Nut Stainless Stainless Hardware with Bolt with Split-Lock Washers Split Lock Bonding Adjustable Bonding Mid Clamp Bonding Standard Washer End Clamp 242ozoss Rail Splice Ground Lug 242-02067 242-04015 242-02101 12-6 AWG Copper Wire Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) Universal End Clamp(UEC) Wave UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF Universal End Clamp 242-02215 Standoff Clamp Assembly Rubber Serrated Stainless Channel Channel Nut Rain Collar Steel Flange Nut Nut Stainless Serrated Stainless Flange Nut Mill Finish Steel Flange Bolt 92 Degree Stainless Standoff L Foot Flange Bolt • All Purpose L Foot Mill Finish Standoff Base(1-Hole L Foot Metal Roof Base Shown) m Mill Finish ,-eFlashing Base Assembly oot L FBase y_'/ v Metal Roof Base StandoffL Foot Base with Flashing __J with L Foot 24292057 242-92050 242-^.1111 SERIES 100 TECHNICAL DATA • 6000 Series aluminum Materials • Stainless steel • Galvanized steel and aluminum flashing • Silver and black anodized aluminum • Mill finish on select products Material Finish • Silver or black coated hardware Note:Appearance of mill finish products may vary and change over time. Wind Loads 110 - 190 mph (ASCE 7-10) Snow Loads 0 - 120 psf Array Pitch 0 - 60 degrees 877-732-2860 www.snapnrack.com contact@snapnrack.com ©2016 by SnapNrack Solar Mounting Solutions. All rights reserved snapNra kse es_l oo Bocnure z.l