Loading...
HomeMy WebLinkAbout47104-Z :r �O�g11�FFOl�tpGy� Town of Southold 3/22/2022 0 P.O.Box 1179 z 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42937 Date: 3/22/2022 THIS CERTIFIES that the building GENERATOR Location of Property: 200 Rogers Rd., Southold SCTM#: 473889 Sec/Block/Lot: 66.-2-16 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/29/2021 pursuant to which Building Permit No. 47104 dated 11/10/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. Maintain 36 inch clearance from shrubs. The certificate is issued to Carini,Joseph&Laura of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47104 1/21/2022 PLUMBERS CERTIFICATION DATED Autlioriz ignature �o�SUEFaiqr�o TOWN OF SOUTHOLD �y BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE "oy • o�� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47104 Date: 11/10/2021 Permission is hereby granted to: Carlini, Joseph 35 Prospect Park W 5E Brooklyn, NY 11215 To: install generator as applied for. At premises located at: 200 Rogers Rd., Southold SCTM #473889 Sec/Block/Lot# 66.-2-16 Pursuant to application dated 10/29/2021 and approved by the Building Inspector. To expire on 5/12/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 u' nspector pF SOUjy®l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(a)-town.southold.ny.us Southold,NY 11971-0959 Q lyc0UM,8,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Joseph Carini Address: 200 Rogers Rd city:Southold st: NY zip: 11971 Building Permit#: 47104 Section: 66 Block: 2 Lot: 16 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Paul Burns Electrical License No: 3897ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service X Commerical Outdoor X 1st Floor Generator X New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks Disconnect 1E Switches 4'LED Exit Fixtures Pump Other Equipment: 18kW Generac Generator w/ 200A Whole House Transfer Switch 200A Panel 42 Circuit/23 Used Notes: Generator and Panel Inspector Signature: c� Q, Date: January 21, 2022 S.Devlin-Cert Electrical Compliance Form SOUIyO� 1 t/ Ll -2-u o ad TOWN OF SOUTHOLD BUILDING�EPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [: .] ROUGH PLBG. [ ] FOUNDATION 2ND: [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ]' FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT'CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: �/` /j DATE INSPECTOR Iv %f S00Tyo<o # # TOWN OF SOUTHOLD BUILDING .DEPT. 765-1802 INSPECTION [ ] -FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND = [ } SULATION/CAULKING [ ] FRAMING/STRAPPING [ FINALI&VI&AV 3 [ ]- FIREPLACE & CHIMNEY' [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT°CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ]' ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O R MARKS: l OVI� (A*tho(. ` .DATE INSPECTOR /qk* FIEI D:INSPECTION~REPQItT. DATE COMI��NTS FOUNDATION 1ST ------------------------------ TOUNDATION'(2ND.). . y e ROUGH FRAMING.& . PLUMBING''.. INSULATION.PER N.-Y. . �y. STATE ENERGY CODE Q 4d FINAL .. y i ADDITIONAL COMMENTS 0. 1-Z r °z d o�oSUFFotrooG TOWN OF SOU'1'HOLD—BU11.DILNG DEPAKfMEN'1' a� y� Town'Hall Annex 54375 Main Road P. 0.Box 1179 Southold, NY 11971-0959 N 2, oy�1 'Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownnV.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D E v L� � � E PERMIT NO.Z:J Building Inspector: OCT 2 9 2021 Applications and forms must be filled out in their entirety.IncompleteTOWN OF UIG DE OLD applications will not be accepted. Where the Applicant Is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: ,� ��� SCTM#1000- ---------o------ ------ Project Address: ,ZdO Phone#: �/�-.?�v p/p Email: Mailing Address: CONTACT PERSON: Name: Q,f -- . _-__-___ -____ Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address.- Phone#: Email: CONTRACTOR INFORMATION: Name:;:...0 er<.7 Mailing Address:.fi�//v- _•�f ...?S____-.._ __._ __ �._ // / .-._- ---.._ _ .--_-._._. _ . . Phone#: 61/_ X63 _ ;3 / Email: DESCRIPTION OF PROPOSED CONSTRUCTION El New Structure ❑Addition ❑Alteration ❑Repair ❑Demolitions C Estimated Cost of Project: ❑Otherae,�.1'e Will the lot be re-graded? ❑Yes XNo Will excess fill be removed from premises? ❑Yes ,eNO 1 L PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ❑No IF YES,PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code.APPUCATION IS HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuantto the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions;alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210AS of the New York State Penal Law. Application Submitted By(print ame): Ari C✓a1'�— Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) COUNTY OF Vpolk ) -bay-, \-es+ being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractr,Agent, orporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 2qday of ,20 Notary Public TRACEY L. DWYER PROPERTY OWNER AUTHOR PUBLIC,STATE OF NEW YORK NO.01 DW6306900 (Where the applicant IS not the Owner) QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2Qp I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 [\\nnII 7 SUE �� 21 BUILDING DEPARTMENT-Electrical Inspector ��O Gym C� 2 9 ZDV TOWN OF SOUTHOLD C* owN o�S;uo Down Hall Annex- 54375 Main Road - PO Box 1179 OF Southold, New York 11971-0959 Ot. Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a-)southoldtownny.gov- seand(cD-southoldtownny.4ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: /0 2� z/ Company Name: ��,��.��•- /cam�-�-� Electrician's Name: License No.: Elec. email: Elec. Phone No: 63i-SGS- Y17.? ❑I request an email copy of Certificate of Compliance Elec. Address.: S. 411P?� 41y7/ JOB SITE INFORMATION (All Information Required) Name: Address: Cross Street: Phone No.: 4P Bldg:Permit#: email: Tax Map District: 1000 Section: Block: / Lot: ii iG BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Cleardit Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ Y I=S M NO ❑Rough In ❑ Final Do you need a Temp Certificate?: YES❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# [:]New Service[-]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead #Underground Laterals 1 2 D H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION PERMIT# Address: Switches Outlets GFI's Surface. Sconces H H's UC Lt's . ,.,.. 3 Fans _ Fridge HW Exhaust. Oven WAD .... Smokes DW Mini IVhcro ... . Generator Cooi<top Tr-ansfer. AC _ AH ' . .'Hood Service Amps ` Nave Used .Special,..._. o Comments: SURVEY OF PROPERTY 4 090, AT SOUTHOLD TOWN OF SOUTHOLD SUFFOLK COUNTY N Yvo AO 1000 - 66 - 01 111 16 oo c, 0 SCALE. lflf 30' 0 - MAY 1, 2003 0 \ � o :. 2� -..y 7. jAf ,e K, ►k -00' asPh A0 0 32,3 r 00 vo CV CERTIFIED To, VIVIAN EYRE BARRY LPPMAN Act tone NOTE, LOT NUMBERS ARE REFERENCED TO 10 MAP OF BEIXEDON ES TA TES BLOCK 4 FILED IN THE SUFFOLK COUNTY CLERKSNrip OFFICE ON MAR. 16, 1946 AS MAP NO, 1472 Q 1.me BUILDING 0 %0 Zp TOWN OF SOUTHOLD / * Ail ANY AL TFJ?A TION OR ADD17YON TO THIS SURVEY IS A VIOLATION OF SECT" 7209 OF THE NEW YORK STATE EDUCATION LAW. EXCEPT AS PER SECTION 7209 - SL49DIVISION 2. ALL CERTIFICATIONS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF OJVL Y IF SAAD MAR OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR WHOSE SIGNATURE APPEARS HEREON VA\e?o N_Y. . A ADOITOOLLY TO COMPLY WITH SAID LAW TERM ' ALTERED BY ZfitCONIC &)#FEYORS, P.C. MUST BE USED By ANY AND ALL SURVEYOR$ UTXJZ1Af6 A COPY 163I1 765 - 5020 FAX (631) 765 - 1' 97 OF ANOTHER SURVEYOR'S MAP. TERMS SUCH 'INSPECTED 'AND P. O. BOX 909 ' BROUGHT - TO - DATE ' ARE NOT fN.COWLIANCE WITH THE LAW. I AREA = NIWW�_ 1230 -TRAVELER STREET SOUTHOLD, N.Y. 11971 03 - 168 C� APPR VED AS NOTED DATE: FEE: BY. NOTIFY .-BUILD IN G DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH FRAMING & PLUMBING 3. INSULATION 4. FINAL CONSTRU-TION MUST BE COMPLETE FCD= r.0 ALL-CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED A^µ1NryriD�/-yIC�OONAIADITIONS OF IIVLV iv..il SOMP,A_ �NG BOARD SOUnmo[97OW1�" I STEES N.Y.S­Dt� OCCUPANCY OR USE IS UNLAWFUL WITHOUT CER:TIFICAl-r- WF OCCUPANCY ELECTRICAL INSPECTION REQUIRED GENERAC® J uUmnuim UR a7CRICa7 1 V/ 1 `r/ 1 V RVI1 k�/�/ nesiaenuai sianaaY venerators i Air-umea uas tnglne r , INCLUDES: Standby Power Hating G007171-0,G007172-0(Aluminum-Bisque)—10 kW 60 Hz • True Power- Electrical Technology 6007223-0,G007224-0,0007225-0(Aluminum-Bisque)—14 kW 60 Hz • Two-line multilingual digital LCD Evolution- controller G007226-0,G007228-0(Aluminum-Bisque)—18 kW 60 Hz (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch • Electronic governor • Standard Wr-Fi®connectivity r • System status&maintenance interval LED indicators + • Sound attenuated enclosure _ • Flexible fuel line connector • Natural gas or LP gas operation GEN_ ERAC • 5 Year limited warranty', • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a - structure.* or C ON usLI*Must be located away from doors,windows,and fresh airc Ous nJ J f intakes and in accordance with local codes. �(V 1 harps://assets.svvri.org'/lrbraly/Directory0fListedProducts/ Note:CETL or CUL certification onlyapplies to unbundled units and units packaged with limited ConstruCilonlndus6y/973 DoC 204_13209 01-01 Rev9.Adf circuit switches Units packaged with the Smart Switch are ETL or UL certified inthe USA only. rrA1 urtta O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and the most The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended run times in high temperatures and extreme operating conditions. surge loads to the engine.Digital voltage regulation at±1 O TRUE POWER-ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG7-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK"WI-FI CONNECTIVITY:FREE with select Guardian Series home standby generators, Mobile Link Wi-F allows users to monitor the status of the generator from anywhere in the world using a smartphone,tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. GENERAC ® :.®� PROMISE Lia.- ��� GENERAC° 1W 14/ 10 KVV reature5 anu Denim Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinderwalls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(f applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution—Controls • AUTO/MANUAL/OFF illuminated buttons Select the operating mode and provide easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load.Setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool priorto shutdown.Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week Offers a selectable setting for weekly or monthly operation,providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 krrvb).Hinged key locking roof panel for security.Liff-out frontfor easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERACW IU/ 14110 KYv rumurus anu ounuum Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI 221.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Linkapplication for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generators complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information foryour specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAL" 1 W 14/ 1 a KW opucinCai10115 Generator Model 6007171-0,6007172-0 6007223-0,6007224-0, 6007228-0,G007228-0 (10 k%9 G007225-0(14 k111N (18 kW) i Rated ntaximum wntmuouspower capaury(LP) -- _ -_ ___ ___-{_ -� 10,000 Watts" _ 14,000 Watts" 18,000 Watfs'_ __ Rated maximum continuous power capacity(NG) 9,000 Watts' 14,000 Watts' 17,000 Watts" - _-_- - _ - ---- - - w - - - --- -- - - -- -- -_-- - ---- 11 volt a 290 - Raied maximum continuous loan cunent-240 volts(LP/NG) 41.7/-37.5 58.3/58.3 75.0/70.8 `Totzl Harmonic OisIRruon�- -�--- -� Less than 5% _ Mainline circuit breaker 45 Amp 60 Amp 80 Amp Number of rotor poles 2 l Rated AC fre enc __60�_ _ -._- _---- -_-___-__-- Pow,erfactor _ -- -,_ _ 1.0 -.-.. . Batte re inrement not included-- "--"•- ---_____-_._.-. ___ __-„__ -_ -- �12Volts Grou^26R 8 - � _. __ _ _-_ __.__ Unit weight(Ib/kg) 3381153 365/175 420/191 - - --- 1Oirnensians(LxWzH}irs/cm -- --- -`- _--_ - I----.------ - - - y_ - 48x25229%121.9z63.5z737 Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load- -- 61 - _ 65 - - -- 65 - ($ound output in dB(Aj at 23 ft(7 m)with generator in 0uief-Test'"low-speed exercise mode'"-' - — �5/ 55-- �-- 55 '--' - Exercise duration 5 min Engine Engine type GENERAL G-Force 400 Series GENERAC G-Force 890 Series Number of cylinders Displacement 460 cc------- 816 cc - I Cylinder block -- - Alminum w%cast iron sleeve Valve arrangement Overhead valve Solid Ignition system Solid-state w/magneto �Governor system Electronic I Compression ratio 9.5:1 -- - _ --- --- - - -- - - -- - -- -- --- -- -- --(St -12VDC_ Oil capacity including filter Approx.1.1 qt j 1.0 L Approx.22 qt/2.1 L 0 Erabn r _ -_ _ ITT-til pm 3,600 _ Fuel consumption -- Natural Gas ft3/hr(m3/hr) 1/2 Load 101(2.86) 195(5.52) 169(4.79) Full Load 127(3.60) 256(7.25) 247(6.99) Liquid Propane ft3/hr(gal/hr)[l/hr] 1/2 Load 36(0.97)[3.66] 65(1.81)[6.87] 62(1.70)[6.45] Full Load 54(1.48)[5.62] 112(3.07)[11.61] 110(3:021[11.44] (Note:Fuel pjpe must-be sjid far full`lo'ad Requirgd`fuel pre-ssrue to gerieratur fuefinlei aCall•(oadranges 3.5-7.0 in eater column(0.87=1.74`kPa)fotNG,10=12 inwater coliirrin(2.49-2]99 kPa)for CP, {gas For BTU content,multiply It 2,500(LP)orft'/hrx 1,000(NG).For Megajoule content,multiply 0/hrx 93.15(LP)or m3/hrx37.26(NO). ; Controls Two-line plaintext multibngual LCD__»- - --- - Simple user intertaceforeaseof operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi`Meekly,or Monthly selectable exerciser. - MANUAL -- - -'— - - - Start with starter control,unit stays onTMlf a ily fails transfer to load takes place._ - OFF Stops unit Power is removed.Control and charger still operate. _-Standard_- Engine run hours indication -- - - Standard EProgrammable start delay beMeen 2-1500 seconds _ __ - `- --, Standard(programmable 6y dealg� Utility voltage IossuRetum to utility adjustable(brownout matting) From 140-171 V/190 216 V ]Future set capableexeruser/Exercrsese1 error warmng _ --_-_� _ — -_- -- -_ Standard � ._�--_- RuMAlarrnvMaint�enance logs 50 events each Engine start sequence__-- _ - _ _ __Cyclic cranking:l6 sec ori,7 sec ret(90 sec mardrnum ducat on). Starter lock-out Starter cannot re-engage until 5 sec after engine has stopped. �Smaft Battery Charger______.--e...____._ Charger FaulVMissing AC WarningStandard Low Baft4/Bat*Problern Pretecfionand BaftgConditionlndica6on-- Standard - I Automatic Voltage Regulation with Over and Under Voltage Protection Standard (Under_Frequency/Overload%Stepper Overou�re Prtectio_n Safety Fused/Fuse Problem Protection Standard Autarrtatic Lovr Oil Pressure/High Oil Temperature Shufdoton -- - J Standard OvercrarVOverspeed(@v 72 Hz)/rpm Sense Loss Shutdown Standard (H'j Engine Temperature Standard Internal Fauloncorrect Wiring Protection Standard Common External Fault Capability--_ Standard Field Upgradable Firmware- ___--------------------------------------- Standard--------------•----------- --. Rating definitions-Optional Standby.Applicable for supplying backup power for the duration of the utility pourer outage with correct maintenance performed.No overload capability is available for this rating.(A[ ratings in accordance with BS5514,ISO3046,UL2200,and DIN6271). 'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine paver and condition,etc.Maximum pourer decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level and approximately 1%for each 10°F(6°C)above 60°F(16°C).""Sound levels are taken from the front of the generator.Sound levels takenfrom other sides of the generator may be higher depending on installation parameters. GENERACW IU/ 14/ 10 KW Own" UP11u S Limited Circuits Switch Features Model 6007172-0 6007224-0 (10 kW) (14 kW) • 16 space,24 circuit.Breakers not included. __. -- • Electrically operated,mechanically-held contacts for fast,positive connections. Current rating(amps) • Rated for all classes of load,100%equipment rated,both inductive and iVoltagerating(VAC)_ 120%240,1H resistive. Utility voltage monitor(fNed)` • 2-pole,250 VAC contactors. -Rck-up 60% • 30 millisecond transfer time. -Cmpout 65% • Dual coil design. tReturntil'tou -_- — Approx-15 sec Exercises bi-weekly for 5 • Rated for both copper and aluminum conductors. -- _ w .minutes* St . _ " - tandard • Main contacts are silver plated or silver alloy to resist welding and sticking. or UL Listed - Standard ETL • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor _.- - --- ------- -- ' -- Total circuits available , 24 mounting flexibility. -- --- -------- --___-`_T_ • Multi listed for use with 1 in standard,tandem,GFCI,and AFCI breakers from !Tandem breaker capabilities _ — 6 tandems -- - --- - Siemens,Murray,Eaton,and Square D for the most flexible and cost effective Circuit breaker protected install. Available RMS Symmetrical 10,000 Fault Current C2 250 Voks Dimensions Function of Evolution controller Exercise can be set to weekly or monthly Height Width Depth w' Hi H2 Wi W2 inE67.94 75 30.1 10.5 13.5 6.91 crri 76.43 26.67 34.18 17.54 Wire Ranges Conductor Lug Neutral Lug Ground Lug 210-#14 210-#14 210-#14 Service Rated Smart Switch Features Model G007225-0 G007228-0 • Includes Smart A/C Management(SACM)module standard. (14 kw) (1 B kW) • Intelligently manages up to four air conditioner loads with no additional No.of poles --_ _2 _ hardware. Current rating(amps) 200 • Up to eight large(2 40 VAC)loads can be managed with Smart Management Voltage rating(VAC) 120/240,114 —� Modules(SMMs). Utility voltage monitor(fixed) • Electrically operated,mechanically-held contacts for fast,clean connections 410pou 6D% • Rated for all classes of load,100%equipment rated,both inductive and �opo� 665%_ --------_---_--_ Return resistive. i to utility`___— -__ —- ~15 sec u -- __ • 2-pol e,250 VAC contactors. Exercises bi-weekly for 5 minutes" Standard - - • Service equipment rated,dual coil design. +Eft or 6L Listed • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. ;Cireiiit breaker protected__ ^__A_ -'---2-2-,-00-0 • NEM/{/UL 313 aluminum outdoor enclosure allows for indoor or outdoor Lug range 250 MCM-#6 mounting flexibility. 'Function of lyolution Oontroller Dimensions Exercise can be set to weekly or monthly LN 200 Amps 120/240,1 e IJ Open Transition Service Rated Height Width Depth Hi H2 W1 W2 in 26.75 30.1 10.5 13.5 6.3 H, crri 67.94 76.45 26.67 34.3 16.01 Wire Ranges Conductor Lug Neutral Lug Ground Lug n=Pm 400 MCM-#4 350 MCM-#6 210-#14 GENERAL' 1 W I4/ 10 Kw Ramco mcumurm Model# Product Description 005819-0 Y 26RVLCCall Battery fryerystehdbygeneratorrequires abattery tostart thesystgn.Generaoffers therecommended26Rwetcalbat-{ l tery for use with all air-cooled standby product(Excluding Powerl"o ). The pad warmer rests under the battery.t�acommended for use if the temperature regularly falls below 0°F(-18 6007101-0 Battey Pad W3mer 1q. (Not necessary for use with A(ivt-style batteries)- 01 warmer slips directly over the cil filter.Recommended for use if thetemperatureregularly falls below 0 T(-I B atteries)-Oilwarmerslipsdirectlyoverthecilfilter.Recommendedforuseifthetemperatureregularlyfallsbelow0°F(-IB T) ` 007103 1 l Breather W ]]er The breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only int climates where heavy icing occurs. G005621-0 �AuiliayTransferSwitch The auxiliarytransferswitch contact kit allows thetransfarswitchto lockout asingle large electrical loadyou may Contac IGt Lnot need.Not compatible with 50 amp pre-wired switches. The fascia basewrap snaps together mound the bottom of the new air cooled generators.This offers a sleek,con-] GDO7027-0-Bisque Fascia Base Wap Kut toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. i If thegenerator enclosure is scratched or damaged,it is important to touch up the pant to protect from fiture' 6005703-0-Bisque Touch-Up Paint Nt I corrosion.The touch-up paint kit indudes the necessary pant to correctly maintain or touch up a generator en-! 1 closure. I (-006482-0—10 kW I Scheduled Maintenance KA Generads scheduled maintenance kits provide all the items necessaryto perform complete routine maintenance( 007216-0—14/18 kW r i on a Grnerac automatic standby generator(oil not ind uded). i _ I The W-H enabled LP fud level moritor provides constant monitoring of ike connecled LP fuel tank.-Monitoring{ 6007005-0 W-H LP Rud Level Monitor the LP tanks fud level is an important step in verifying the generator is ready to run during an unexpected power] { I failure.Status alerts are availablethrough a free application to notify users when the LP tank is in need of a refill. 6007000-0(50 amps) Smart Management Modules(SMM)are used to optimize the performance of a standby generator.it manages I 6007006-0(100 amps) Smart Management Module large electrical loads Upon startup and sheds then to ad in recovery when overloaded. In many cam,using] 1 SMM's can reducethe overall sim and cost of thesystem. ! (007169-0(4G LTE) The Mobile Link family of Celes (WCellular Accessories allow users to monitorthe status of the generator from anywhere I. 6007170-0 -H/Bher- Mobile Link®(anular Inthewodd,using asmadphone,tatic,or PC Easilyacoess information such as the c Trent operaingstatus and net) I Accessories iIi maintenance alerts.Users can connect an account with an authorized service dealer far fast,friendly,and proac- tive service.V1fth Mobile Link,Users are take]care of before the read power outage. Dimensions & UPCs , -an .---637.6 mm [46.48.0 in] x25.1 m] Model UPC - G007171-0 696471074680 G007172-0 696471074673 G007223-0 696471082548 2P gmm r2a.6 in] G007224-0 696471082555 G007225-0 696471082562 G007226-0 696471082579 1 o ® 0 0 G007228-0 696471082586 mm I=— [48.51-1 LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See inslallation manual for exact dimensions.DO NOT USETHESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC' Ge,e rac Pbvvea sysbNns,Inc.a345 VM290 HVW.59,Waukesha, 53189 iwenerac.conn ©20200macPdmwS Aerns,Inr AUrightsreswed Alspecff'cationsare subjedtodungewithournotic.Pat No.PD0009=4 FW.A 1 0/2 22 0 2 0