Loading...
HomeMy WebLinkAbout46984-Z r�.FE01 Town of Southold 3/5/2022 P.O.Box 1179 � �T 53095 Main Rd oy o� JSouthold,New York 11971 4 4f, fr XT71YJj'L' CERTIFICATE OF OCCUPANCY No: 42883 Date: 3/5/2022 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 3900 Alvahs Ln., Cutchogue SCTM#: 473889 Sec/Block/Lot: 102.-4-3.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/1/2021 pursuant to which Building Permit No. 46984 dated 10/15/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"alterations to existin single-family dwelling as applied for. The certificate is issued to Dalton Studios LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46984 1/13/2022 PLUMBERS CERTIFICATION DATED 2/3/2022 (,jhonp\Maloneyfi th riz 'gnature Su4Fnt�c TOWN OF SOUTHOLD BUILDING DEPARTMENT 0 ' TOWN CLERK'S OFFICE • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46984 Date: 10/15/2021 Permission is hereby granted to: Lademann, Joan 3900 Alvahs Ln PO BOX 123 Cutchogue, NY 11935 To: legalize "as built" alterations to existing single-family dwelling as applied for. Additional certification may be required. At premises located at: 3900 Alvahs Ln., Cutchogue SCTM #473889 Sec/Block/Lot# 102.4-3.2 Pursuant to application dated 10/1/2021 and approved by the Building Inspector. To expire on 4/16/2023. Fees: AS BUILT-SINGLE FAMILY ADDITION/ALTERATION $500.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $550.00 B k ding Inspector ®�*OF 30UPy®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 • ao� sean.devlinr'D-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Dalton Studios LLC Address: 3900 Alvahs Ln city:Cutchogue st: NY zip: 11935 Building Permit#: 46984 Section: 102 Block: 4 Lot: 3.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: RNIB Electric License No: 3542ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor X Hot Tub Addition Survey Attic X Garage INVENTORY Service 1 ph X Heat Duplec Recpt 21 Ceiling Fixtures 4 Bath Exhaust Fan Service 3 ph Hot Water Gas GFCI Recpt 6 Wall Fixtures 3 Smoke Detectors 3 Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 18 CO2 Detectors Sub Panel A/C Blower 1 Range Recpt Gas Ceiling Fan Combo Smoke/CO 3 Transformer UC Lights Dryer Recpt 30A Emergency Fixtures Time Clocks Disconnect Switches 1 g 4'LED Exit Fixtures Pump Other Equipment: Hood, Gas Oven, DW, micro, 200A Panel 40 Circuit/ 25 Used , W/D Notes: Most of House Renovation Inspector Signature: Date: January 13, 2022 S.Devlin-Cert Electrical Compliance Form Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(63I)765-9502 P.O.Box 1179 Southold,NY 11971-0959 p � BUILDING DEPARTMENT TOWN OF SOUTHOLD FCB 2022 I BUILDING Ori-"' TOWN OF SOUTHOLD CERTIFICATION Date: 12, Building Permit No. f �� Owner: o p (Please print) Plumber: (Please print I certify that the solder used in the water supply system contains less than 2/10 of 1%0 lead. - Sign &, Sworn to before me this (PIumbers Sig day of—RbNa!:j! , 20 as Amber Vissichelli NOTARY PUBLIC,STATE OF NEW YO Registration No.o1 VI6336399 Notary Public, �/ Qualified in Suffolk County �1 1�_ CQunty Commission Expires July 21,2024 *DF SOp yOlo -9 &loq 390a # TOWN y , TO OF SOUTHOLD BUILDING DEPT 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. ] FOUNDATION 2ND - [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL ="[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION" [ ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [( ] CODE VIOLATION [ ] PRE C/O REMARKS: -iy 44A 14 in e/N t r putl flevV Wl** fA-i NWII-e 01A IS r-aA iqv4�t�—g 0-p 6 G DATE INSPECTOR 1 hO��pF S0U1y06 V o o Al - - # . �ILDING DIERT.- . TOWN OF...SOUTHOLD U �ibnm � 765-1802 INSPECTION [ ] FOUNDATION IST [ ]- ROUGH PLBG. [ ] FOUNDATION 2ND a..[ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ '] FIREPLACE & CHIMNEY" [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ]" PRE C/O REMARKS: -- ®`�` (. o f 4r _Co "2- +70C 6_^oflfTe_6_LL-22 s DATE 14 INSPECTOR G� Of SOUIy�� # TOWN OF SOUTHOLD' BUILDING DEPT. 765-1802 INSPECTION ( ] FOUNDATION 1ST [ ] ROUGH'PLBG. [ ] FOUNDATION 2ND [ rSAULATIOWCAULKING FRAMING /STRAPPING [ NL [ ] FIREPLACE & CHIMNEY [ ] "FIRE SAFETY INSPECTION-. [ ] ,FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION' [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) = ( ] CODE VIOLATION [ ] PRE C/O REMARKS: . - - - DATE ll INSPECTOR �apF SOGIyo 4:94& 09 UV l V VV aO l -- # # TOWN OF SOUTHOLD BUILDING DEPT. / v �`y�ourmN�' 765-1802 INSPECTION ( ] FOUNDATION 1ST [ f ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IdSULATIOWCAULKING [ ] FRAMING /STRAPPING [Vf FINAL [ ] 'FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLAT [ ] PRE C/O REMARKS: ffA/VA,.5 9D _�o ?Nowr I R LA-Vo P V,qs 0'�o Qr�J �I�tDovclS Q ee✓s -f—� �►� � PWVNZ 15 4 b- N I, p**74'sc Diu &V[VM�XA6 �� DATE o INSPECTOR SOUIyO� Cd� e 313 ®e) AWA4 5 L I # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE:& CHIMNEY" [ ] FIRE-SAFE-TY INSPECTION [ ] -FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) °[ ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O REMARKS: - 5-W-4 5-f'&<- J J.", c( a-_ nce IA 6rr_o.Anedec4 AeeJ, combo l� 1 f - &o4 _/Z vc/0 6_01j�gM_ CA_� A A ;,2-A A 0 pp A2 IlAe DATE .� Z�I INSPECTORS qO0 OF SOUTy�� # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [Vf FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ], ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] RE C/O REMARKS: 6) L� - !� y " W • �✓ Vw vw DATE L��w INSPECTOR ho��pF SOUIyo� et at -144v-m l.r-- TOWN- OF SOUTHOLM BUILDING DEPT. `ycouHr+N�' 765.1802 INSPECTION -1 [. ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ .] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL ] FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ } FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O reLj REMARKS: ff Arie, —�` f DATE ANSPECTOR ooe � Tiderunner Engineering & Design, P.C. 7 Ridgewood St Bay Shore, NY 11706 (631)-839-4524 January 23,2022 Building Inspector Town of Southold C E r 53095 Main Road ® F Southold,NY 11' 51 FEB m 4 2022 Fpi :. BUILDING DEFT TOWN OF SOUTHOLD Re: Plumbing Certification 3900 Alvah's Lane,Cutchogue,New York Dear Sir or Madam. I have reviewed the plumbing installation at subject address to determine if it is in compliance with Current Codes Based on any review I find that the plumbing has been installed in accordance with New York State Residential Code. If you have questions please feel free to call Y cj� 14EW � Sincerely, w Louis Schwartz,P. 17 "R0FFIES Tiderunner Engineering & Design, P.C. rt4, 7 Ridgewood St Bay Shore, NY 11706 (631)-839-4824 January 23, 2022 Building Inspector Town of Southold 53095 Main Road Southold,NY 11751 Re: Plumbing Certification 3900 Alvah's Lane, Cutchogue,New York Dear Sir or Madam. During the course of the construction the homeowner decided they did not want to install the two columns that the approved plans show There is an existing 3,'/2 x 9 1/4 Anthony Power Beam header that is not conforming to Code requirements and instead of removing the existing header is to remain and a double 3 '/2 x 9 1/4 Anthony Power beam was installed under the existing header This creates a composite beam 18 1/2 inches deep and the calculations show it will support the anticipated loads. The two beams are connected together with steel strapping sixteen (16) inches on center As part of the this project all exterior walls,ceilings and floors were insulated as pre Coe requirements. If you have questions please feel free to call af NEW ro SCNtyqSincere , w f'J' 77006 �� Louis Schwartz, P.E. ���R�FESSI�NP� ® ECLS ,U NEW YORK IBUINNDLo G FEB — 4 2022 ED G R OiU P BUILDING DEFT TOWN OF SOUTHOLD Affidavit Of 2020 ECCC Compliance Date: 2/3/2022 Inspection Address: 3900 Alvahs Lane, Cutchogue NY 11935 This is to Certify that on 1/19/2022 the above address has been tested in accordance with the provisions of the 2020 New York State ECCC: Conditioned Floor Area: 1 1575 lConditioned Volume I NA R403.3A: Duct Leakage (Duct Blaster Test)The Building duct and plenum system has been tested by in accordance with Appendix A of National Home Energy Rating Technical Guidelines and ASHRAE 152, and meets the minimum requirement of: <4 cfm25pa per 100 Ft2 of conditioned floor area. System 1:. Bsmt Leakage CFM@25: 1 52 Supply R-value: R8 Return R-value: R8/114 System 2: 1 Leakage CFM@25: Supply R-value: Return R-value: System 3: Leakage CFM@25: Supply R-value: Return R-value: Total Combined Leakage: 52 CFM@25 Leakage Limit: 1 63 JCFM@25 R403.3.4 2020 ECCC Compliance: PASS Signature of Certified RESNET HERS Rater: HERS CIA Provider: Performance Systems Development 124 Brindley Street, Ithaca NY 14850 Provider ID#: 1998-072 om Baccarella Certification #3587347 607-277-6240 Notice of independent Status.As per the requirements the 2020 Building Code of NYS, New York Building Technology Group Inc. and/or it's Inspectors(Raters)are not and shall not be owned,controlled by,or have shared financial interest with the owner of the project, the General Contractor,the subcontractors,or any entity responsible for the construction or management of any project inspected by this agency.I further certify that as independent third party Inspectors(Raters),New York Building Technology Group Inc.and its employees shall avoid conflicts of interest with regard to its professional activities. 159 Route 25A, Bldg 1 Suite B, Miller Place, NY 11764 Telephone: 631495 0289 Fax: 631509 4538 Email: NYBTGTB@gmail.com b _v. R....._.. ... .cj• i r f t state a, ♦WIYMIM6 / r - i � -- 4y /; I I a �xi. �� ,� �_. .;�=.�x ...�.- ,� r^ • y a s N e l l • � • • • FOUNDATION ------------------------------- � 1 • 1 ® s . • 1 ZIM millr = 1 � m l TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 hLtps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ® E w E PERMIT NO.J�V Building Inspector: OCT 0 12021 ISI', ' ' BUILDING DEPT Applications and farms must e'ftflied out t TOWN OF SOUTHOLD be accepted Whererthe Applicant is notth'e owner;an completed J 9 d rn ;,-sha Date: OF SCT Name- M#1000 A L d F - ,A9AI—rOV ,r' VAQ10 9 _.L_G , -. ­­ '. I ­­ .111- - .. -_Z02,- . . ' z Project Address 4N.,iF0' .r . . ­ ­ 1.1-1 - W 6& - Phone#: 9,1,7, 6 .6, 772- Em Mailing Address:,? _W41L S.T 2Z COW C ONTACTV ERS 0 Name:. IWA64 Mailing Address'...,,, P10, g 10 1190'4/,_0X. Phone#: I 'Ema - 316- 6,59 06017 . '!P41 WO C&.Z( !1ZVVZ01V IW7 RESIGN kp S IN �kL F �110 Name: Al C9 04n(Y-Al BLEVICES Mailing Address: Phone#: Ema 16 "dw 00 0rl INFORMATION V- 1 Name: Z2V2, Mailing Address: Phone#: Email: 'D SCRIPTCONSTRUCTION E]NewStructure OAddition N�Alteration XRepair ElDemolition Estimated Cost of Project: Dother $ Will the lot be re-graded? E]Yes )(No Will excess fill be removed from premises? E]Yes Ao W PROPERTY INFORMATION Existingof property: ,use p p Y' Intended Ilsof property���l��y�/�G !— e E Zone or use district in which premises is situated: i Are there any.covenants and restrictions with respect to L- 40 this property? r7Yes AQ IF YES,PROVIDE A COPY. ❑Check Box After Reading.' The owner/contractor/design professional Is responsible fora ll:drainage.and storm water Issues as provided by chapter 236 of the Town Lode.APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone I Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regul6tions,for the construction,of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premiser.iind In.-building(s)for necessary inspections,raise statements made herein are punishable as a Class A misdemeanor pursuant to Section 220.45 of the New York State Penal Law, . p Application Submitted By(print name); fgICy,4ELe ;. ��/ � XAuthorixed Agent ElOwner p� C Signature of Applicant; /C�c� Date; STATE OF NEW YORK) (. SS COUNTY-OF_�YlF�UL ) bein duly sworn,deposes and says that(s)he-is the applicant (Name of individual signing contract)above named, (5)he is the �?,�5eSGT (Contractor,Agent,;Corpfflcee "'etc) of said owner or owners,and is duly authorized to perform cir hare performe the-said workand to make and file this application;that all.statemenfs containeo in this application'are.true to the best of.his/her knowledge and belief;and t that the work will be performed in the manner set forth in the,application flle.:therew,ifh: s Sworn before me this I; day of dCr'OR 20.%L . . .Notary Public --- a gRigN Notary P blic State ANDREWS. PROPERTY OWNER AIiTHORIZATIO,N Oualifie 02AN50745ogew York (Where the applicant is.,not the"owner.) Commission EXn Suffolk Count `.. Aires p7 1, 1.41 dAL"rOA1, jM!�,�residing at,*v-,5' lA/,1111.1'7" �T r rv> ./Z:Z4,_do hereby authorize L�fJCf A'/&Q[K to apply on R my behalf to the Town of Southold BuildingDe for Department p approval as described herein. Owner's Signature Date Print Owner's Name ( e z ii i ®SVfFOj,�, Oct 2 R ���1ZING DEPARTMENT- Electrical Inspector �� pEpt TOWN OF SOUTHOLD o of S U�61ioown Hall Annex- 54375 Main Road - PO Box 1179 Tow c' Southold New York 11971-0959 o�o` ap� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr—southoldtownny.gov — seand(&-southoldtownnv.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 10/27/21 Company Name: RMB Eletric Electrician's Name: Richard Brzeski License No.: 'ME*3542 Elec. email: info@rmbelectric.net Elec. Phone No: 5162414385 01 request an email copy of Certificate of Compliance Elec. Address.: 148 Verdi Street Farmingdale, NY 11735 JOB SITE INFORMATION (All Information Required) Name: Dalton Studios LLC Address: 3900 Alvahs LnCutchogue, NY 11935 Cross Street: Main Rd Phone No.: 9176566772 Bldg.Permit#: 46984 email: operations@suffolkcountyhousebuyers.com Tax Map District: 1000 Section: 102 Block: 4 Lot: 3.4 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Updating kitchen and bathrooms, and changing outlets in kitchen and bathrooms H- uare S Footage: 15oo q 9 Circle All That Apply: Is job ready for inspection?: 0 YES 0 NO ❑✓ Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES❑NO issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground[]Overhead # Underground Laterals F11 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Pq %C� Rec 1002-31f Nunemaker, Amanda From: Michael Hand <michael@mchdesignservices.com> Sent: Friday, October 15, 2021 8:51 AM To: Nunemaker,Amanda Subject: Re: 3900 Alvahs Lane Ah Cosmetic only Thanks On Fri, Oct 15, 2021, 8:48 AM Nunemaker,Amanda <Amanda.Nunemaker@town.southold.nv.us>wrote: Yes, I need to know what exactly what was altered in the kitchen and bathrooms.Are they being reconfigured or is it just cosmetic alterations? ------------------ -----Original Message----- From: Michael Hand<michael@mchdesignservices.com> Sent:Thursday, October 14, 20216:32 PM To: Nunemaker,Amanda<Amanda.Nunemaker@town.southold.ny.us> Subject:3900 Alvahs Lane i hi Amanda mike kimmick is filing for permits on the house and you were uncertain about whats going on he said the existing kitchen and existing bathe, noted to alter, is being replaced as shown on plans thanks Mike Michael Hand (631) 965-1947 ATTENTION:This email came from an external source. Do not open attachments or click on links from unknown senders or unexpected emails. 1 From: Jeremiah Dalton To: Southold Building Department 12/15/21 Permit#46984 Attention, The following is an amendment to Permit#46984 for address 3900 Alvahs Lane in Cutchogue. This letter is to add doors, windows and HVAC systems that we replaced in make. Jeremiah Da;tpn Homeowner UNAUTHORIZED ALTERATION OR ADDITION n i r� TO THIS SURVEY Is A VIOLATION OF Urea= 14,537 M. DRAWN MM I CHECO MM DATE JULY 2020 DRAWING &JOB NO. 20-620 SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED ` TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY O�� IS PREPARED, AND ON HIS BEHALF TO THE ` TITLE COMPANY, GOVERNMENTAL AGENCY AND v LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI- TUTION. GUARANTEES ARE NOT TRANSFERABLE. s _ THE EXISTENCE OF RIGHTS OF WAY AND/OR EASEMENTS OF RECORD IF aIo c9- ANY, NOT SHOWN ARE NOT a - GUARANTEED. sem. pp' 20� Premises known as: �®f NEW EPS cs, 4\�� 3900 Alvah's Lane, Cutchogue �� �P�L %A�� (Al ce '� �< ® FOR � �® 0 8 CAND sa c 2g,gyp,, Survey of Described Property a 0 o aa' �61 e ,1,, \`, I �� Situate at �7 �5S a-1 ��o \CutchoeQs e Town of Southold Suffolk County, New York ��� o N O District 1000 Section 102 Block 4 Lot 3.2 oN �6ti a�eQ ��� Scale 1 "= 20' Surveyed July 23' 2020 .meg p"�1 Z. �59561 Michael W. Minto, L,S.P. C. LICENSED PROFESSIONAL LAND SURVEYOR =' NEW YORK STATE LICENSE NUMBER 050871 87 Woodvlew Lane Centereach, N.X. 11720 Certified to: PHONE/FAX: (631) 580-1202 DE TITLE SERVICES, LLC DE13694S-20 CELLULAR: (631) 766-9714 � � �6p�p FIDELITY NATIONAL TITLE INSURANCE COMPANY W EMAIL: mikemintolspc®gmail.com CITIZENS BANK, N.A. FRANK W. HOERAUF, III AND PAMELA M. HOERAUF, HIS WIFE OVA DEC 16,2021 Front Door Therma-Tru Benchmark Door Qyt 1 TOWN OF SOUTHOLD 36-in x 80-in Fiberglass Craftsman Left-Hand Inswing Ready To Paint Unfinished Prehung Single Front Door with Brickmould Insulating Core ENERGY STAR Northern Zone ENERGY STAR North/Central Zone ENERGY STAR South/Central Zone ENERGY STAR Southern Zone Item#833538 Model#BMTT626364 Side Door Masonite Qyt 1 36-in x 80-in Steel No Glass Left-Hand Inswing Primed Prehung Single Front Door with Brickmould Insulating Core Item#740774 Model#740774 Windows Qyt 23 JELD-WEN V-4500 23.5-in x 35.5-in x 3.25-in Jamb Vinyl New Construction White Single Hung Window Full ENERGY STAR North/Central Zone ENERGY STAR South/Central Zone ENERGY STAR Southern Zone Item #358386Model #LOWOLJW242200001 HVAC ac unit Qyt 1 Bryant® SentryTM - 3.5 Ton 16 SEER Residential Air Conditioner Condensing Unit Item: BA16NW0430OG MFR: BA16NW0430OG Furnace Bryant® LegacyTM 95%AFUE 60000 Btuh Single Stage 4-Way Multipoise ECM Condensing Gas Furnace Item: 915SB4206OE17 MFR: 915SB4206OE17 All sizes meet ENERGY STAR®Version 4.1 criteria for gas furnaces: 95%+ AFUE.Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193 All sizes meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement COMPLY WITH ALL CODES OF OCCUPANCY ORoa NEW YORK STATE & TOWN CODES APPR VEDAS NO ED AS REQUIRED AND CONDITIONS OF USE IS UNLAWFUL .. DATE: B.P.# qL404 0 WITHOUT CERTIFICATE - FEE: PV• SOf HO! BOARD OF OCCUPANCY NOTIFY BUILDING '_-:PARTMENT AT M C u 765.1802 SAM TO 4FM FOR THE 1 STEES Design Services FOLLOWING INSPECTIONS: Y.S. J I. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE r 2. ROUGH - FRAM;NG PLUMBING ELECTRICAL �s ,,,�p j(� phone: hdesignservices.com 3. INSULATION ATH � C "" " phone: 4. FINAL - CONTQ"!��r;(,N MUST INSPECTION REQUIRED MUD ROOM ALTER (631)298-2250 BE COMPLETE ; ' ) ALL CONSTRUCTiC-,, -.HALL MEET THE email: REQUIREMENTS OF THE CODES OF NEW michael@mchdesignservices.com YORK STAT E. NOT R I r- Fnn DESIGN OR CONSTR CTION — — — LLlL,I o I-:p Additional � o Certification o (.90 r Z May Be Required. -,-,0 >< N F— ITCHEN o ma BEDROOM No. 1 O ALTER r /� LA 1 1 0� +n'(� v ' 1 1 DINING ROOM ° ; ; 0Q-t FN.:P 1 1 4'_611 O NOTE: HALL - 2'0 (3) POST EACH POST TO HAVE LALLY COLUMN C\� o WITH 2'X2'X1'FTG DIRECTLY BELOW `� -01 CLOSET (3)2X4 DF#2 • REMOVE WALL-REPLACE WITH 3-1/2X9-1/4 2.1e 310OF ANTHONY POWER BEAM POST M ----------- --- -------------- ------------ ----------- - --- - ' --- -- - --- rT, ----p ---- ---3-1/2X3-1/2 PARALLAM CV qt Z 0 __-__ ---_ COLUMN(TYR) ^1 ice, --- ---- 41611 8--0" 41611 � ` V a ---------- lie 171-011 ----------- ALTERNATIVE BEAM OPTION: (2)1-3/4X16 LVL w/3/4"STEEL FLITCH PLATE H ----------- UPSET BEAM SUPPORTED WITH 3-1/2X5-1/4 O ,� 1.8e PARALLAM COLUMN AT EACH END rT, w/LALLY COLUMN BELOW ON 2'X2'Xl'FOOTING ----- ---- ------------ BEDROOM --- ---- h+�l BEDROOM No. 2 BEDROOM No. 3 -___------ DIRECTLY UNDER EACH POST 0 a LIVING ROOM ----a ---- ^ CDCD O W M U VolH O U U a� SITTING ROOM 2ND. FLOOR PLAN SCALE: 1/4" = V-0" 1112 I/4 11/9 W` uy DRAWN BY: MH SH ER J Z II/l 3 3 9/25/2021 1ST. FLOOR PLAN .I,A SCALE: SEE PLAN "'° WC. SCALE: 1/4" = V-011 IAy SINK WM. DW. SHD kR C FA1. \ O� 1 V E+w �DII' II/4 I f. SHEET NO: I �Q'`` h DE��kpO�'i 3 3 �� R ` a 1 SLOPE"1/4"PER FOOT PITCH TO DRAIN TO APROVFD W 4-CJ SEPTIC 515lEA /l TRAP IIDUSE l � PLUMBING SCHEMATIC pR0FESS\ SCALE: NOT TO SCALE I' I / WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT & GOOD CONSTRUCTION. FOLLOW MANUFACTURE'S RFCOMM-NDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. M C H KING STUDS - Design Services ENDWALL RAFTER e CRIPPLE STUD WALL STUD RIDGE BOTTOM PLATE www.mchdesignservices.com HEADER LEDGER BATHTUB SIDEWALL DOUBLE JOIST phone: (631)298-2250 JACK STUDS RAFTER FLOOR USP NUMBER DESCRIPTION APPLICATION email: 1ST. ADSS HOLD DOWN CONNECT TO 1 SIDE OF ALL CORNERS michael@mchdesignservices.com ANCHOR TO FOUNDATION W/ ANCHOR BOLTS CONNECT TO 1 SIDE OF ALL CORNERS ON LOCATION USP NUM13LRI DESCRIPTION APPLICATION LOCATION USP NUMBER DESCRIPTION BATH / SPA TUBS TO HAVE A DOUBLE FLOOR JOISTS UNDER FOR ADDED SUPPORT HOLD DOWN BOTH BOT. PLATE OF 2ND FLOOR AND TOP APPLICATION RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR 2ND. ADS5 ANCHOR PLATES OF 1ST. FLOOR. CONNECT THROUGH ALL OPENINGS LSTA72 1-1/4"x12" 20ga. STRAP APPLY TO EACH JACK STUD ROOF LSTA24 1-1/4"x24" 20ga. STRAP APPLY OVER RIDGE TO EACH RAF TE 2x6-2x8 LS26 18ga. SLOPE HANGER APPLY TO EACH RAFTER / LEDGER JOIST DIRECTION WITH (2) JOISTS. UNDER WALL. HE FLOORS TO EACH OTHER W/ THREADED ROD. ALL OPENINGS RT3 OR RT7 TYDOWN ANCHOR APPLY TO EACH CRIPPLE STUD FOR JOIST NOT DIRECTLY UNDER PARALLEL WALLS, PROVIDE 2X10 LS210 18ga. SLOPE HANGER APPLY TO EACH RAFTER / LEDGER BLOCKING 024'OC WALL STUD THROUGH-ROOF EXHAUST VENTS SELECTED AND METAL STRAP ` LOCATED BY CONTRACTOR CRICKET AT TOP-SIDE OF VENTILATION CHANNEL ^ RIM BOARD CHIMNEY RAFTER AS REQUIRED — SILL PLATE(S) WALL SHEATHING • •• RAFTERS MAINTAIN VENTILATION " SIDEWALL FLASHING WOOD JOIST FOUNDATION _ "'• -' i _'" "' TOP PLATE BLOCKING FINISH WALL AND MOISTURE 2x4 LEDGER BLOCKING STAPPING TO BE ATTACHED TO WALL STUDS 048"OC BARRIER TO LAP FLASHING AT WALL -- MAINTAIN GAP 2x4 SOFFIT JOIST AND ALL WINDOW/DOOR OPENING JACK STUDS BETWEEN WALL FINISH AND ATTIC SHALL BE PROVIDED WITH A FASCIA FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION ROOFING TO AVOID SOAKING MINIMUM NET FREE VENTILATING AREA WALL STUD NOT LESS THAN 1/150 OF THE AREA OF GUTTER INSTALL 4'0" O.C. �,'� THE SPACE VENTILATED. ALL OPENINGS WOOD GIRDER 4" - 8" LSTA24 1-1/4"x24" 20go. STRAP AND JACK STUDS 0 SHALL BE COVERED WITH CORROSION- ONTIN. SCREENED VENT ON ALL OPENINGS '�T RESISTANT METAL MESH WITH MESH ONTIN. SOFFIT EXT. PLYWOOD PROVIDE HEMMED EDGE AT OPENINGS OF +/. INCH IN DIMENSION. / INSTALL 4'0" O.C. FLASHING TO FORM CHANNEL LOCATION USP NUMBER DESCRIPTION APPLICATDN A , 8" - 14" LSTA30 1-1/4"x30" 18ga. STRAP AND JACK STUDS AND SO AS TO MAINTAIN AIR ` v ON ALL OPENINGS / GAP TO PREVENT CAPILLARY CONNECT TO SOFFITED EAVE ACTION 4" - 6" RAFTER RT10 10-3/4" x 18ga. TYDOWN ANCHOR INSTALL 4'0" O.C. EACH RAFTER PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND / `' J 14" - 16" LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS 8" - 12" RAFTER RT20 1-1/8" x 20ga. TYDOWN ANCHOR CONNECT TO ROOF VENTILATION SOFFITED EAVE DETAIL OVER BEARING WALLS AND HEADERS ^/ ON ALL OPENINGS KEEP ROOFING NAILS OUT EACH RAFTER ' 1:4 2ND. FLOOR WALL OF FLASHING zo ROOFING LAPS BASE ' i� FLASHING 4 INCHES BASE FLASHING WRAPS CORNERS, RAFTER / uj N a \/ EXTENDS UNDER SHINGLES AT RIDGE CAP OF SAME O SIDES 4 INCHES AND LAPS I MATERIAL AS ROOFING SHINGLES AT BASE MIN. 4 INCHES NAILED TO SHEATHING THROUGH VENT WOOD JOIST ' ^ TOP PLATE.71 O -- GIRDER/HEADER O SIDE WALL FLASHING 1ST. FLOOR WALL STAPPING TO BE ATTACHED TO WALL STUDS @48-OC WOOD JOIST O AND ALL WINDOW/DOOR OPENING JACK STUDS METAL FLASHING AT ALL EAVES, SIDEWALLS, WALL STUD FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION AND RAKES PROVIDE HEMMED EDGES SO O O AS TO FORM DRAINAGE CHANNELS AND RAFTERS INSTALL 4'0" O.C. PREVENT CAPILLARY ACTION Q 4" - 8" LSTA36 1-1/4"06" 18ga. STRAP AND JACK STUDS LOCATION USP NUMBER DKEEP SHEATHING MIN. 1-12 / ESCRIPTION APPLICATION ON ALL OPENINGS PRE-MANUFACTURED CONNECT EACH RIDGE VENT FOLDS " ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH CN INSTALL 4'0" O.C. RAFTER/PLATE RT15 TYDOWN ANCHOR OVER RIDGE TO FROM PEAK TO ALLOW FREE RAFTER TO PLATE AIR PASSAGE THE PROPER STEEL CONNECTOR. 8 - 16" MSTA48 1-1/4"x48" 16ga. STRAP AND JACK STUDS CONFORM TO SLOPE IF ABLE. SET FIR JOISTS APROX. 1/2" HIGHER THAN LVL HEADERS ON ALL OPENINGS PLATE/WALL SPTH4 STUD PLATE ANCHOR CONNECT OVER OF ROOF TO ALLOW FOR SHRINKAGE. & REDUCE BUMP OUTS PLATES TO EACH STUD _ DBL. SILL PLATE TERMITE SHIELD SILL GASKET SUBFLOORWOOD JOISTS V TYP. CONC. FOUNDATION GONG. SLAB DAMPPROOF EXTERIOR n 6 MIL. POLY GASKET 2x6 6MIL POLY ON EXTERIOR V GRANULAR FILL V� 2x6 /2x8 CONTINUOUS WOOD PLATE V . STEEL COLUMN I I , •, •, Q % I %2 DIA. BOLTS 6®A48"N ROLTED TO STEEL .� o.c. STAG. i ♦ d • d o C O CONC. SLAB •p - � s � � ROOF JACK `\♦ G•• � � \.O � ANCHOR BOLT EMBEDMENT �� III STEEL BEAM V COMPACT FILL 4" x 1 4" x 8" STEEL POURED CONCRETE: 7" V • _ p •s BLOCK WALL: 15' ROOFING LAPS % TOP AND BOTTOM PLATE KEYWAY FOOTING ° 4 • 7 • FLASHING AT WITH 1/2" x 6" ANCHOR BOLT �' • � C � °' a C CONC. FTG. •p �•p L o' SIDES AND TOP ANCHOR BOLT CONNECTION USE WITH 3x3 SQUARE WASHERS � REINFORCING BAR (USP LBPS58 OR BP583) 1/2" GROUT I I I �- DRAIN TILE p ANCHOR BOLT CONNECTION FOUNDATION 5/8" DIA. ANCHOR BOLT 3" STEEL COLUMN SUPPORTING MAXIMUM SPACING FLASHING LAPS I I ( 10 KIPS ) SILL PLATE TO FOUNDATION 1 STORY 72" OC ROOFING AT BOTTOM ' CRAWL SPACE OR FOUNDATION TYPICAL CONC. FOUNDATION. APPLY PILASTERS SILL PLATE TO FOUNDATION WERE TYPICAL BEAM DETAIL ERE NEEDED FOR STRUCTURAL BRACING. MIN. 3" STEEL COLUMN ANCHORED TO 24"x24"x12" CONC. FTG. CRAWL SPACE OR FOUNDATION 2 STORIES 36" OC ALL BOTTOM PLATE TO FOUNDATION STEEL / BOTTOM BEARING 1-2 STORIES 57" OC SLAR-ON-GRADE ROOF JACKS & VENTS DETAIL LAB SUB FLOOR 6X6 10/10 WWM IDOOR FRAME COMPACT FILL GARAGE DOOR DRAWN BY: MH �_JOIST USE 2X8 STEEL BEAM FOR BLOCKOUT 4" SLAB •" P.T. PLATE •" W/ 6X6 WMM \I - SLOPE ' 1/2" AIR SACE •� 1 - • e"M 4"DRIVEWAY —# NOTCH JOIST AND ADJUST HEIGHT 9/25/2021 " •,- C AT END AND ,• 7 1 2" • •• - •• - - (WITH A NAILING PLATE IF NEEDED) GRADE ' a ---I------a--Q--+ �" t,s�'n ES OF WOOD a •o • °• =' • TO BE APROX. 1 2" OR HIGHER THAN �• BEAMS `� O o• O •• •. STEEL BEAM TO ALLOW FOR SHRINKAGE O I++i I •• 0 • - (PROVIDE STRAPPING TO KEEP JOISTS ALIGNED) SCALE: SEE PLAN 12" 6X6 W.W.M. ••� - - - - +7 C MIN. ° P •o O a d A ' a �.• J p O • .o ••O•'O _ •e'° • • �'e1 i:'A �• •e ��NOTCH BEAM FOR MUDSILL IF REQUIRED -- MAXIMUM •0 . SUB FLOOR d REINFORCING BAR NOTCH EQUALS 1/4 DEPTH OF BEAM O e o• • ° o DRAIN TILE I� �J�) •C e REINFORCING BAR s•_ a 12" p•a-o >' ° �i�11 01ST _ . C o •e SHEET METAL/ 30y FELT UNDER BEAM AT POINT 11•A 0 !O • O • OF CONTACT WITH CONCRETE OR CONC. BLOCK _ I• Y,�♦ TEEL BEAM TYPICAL CONC. MONOLITHIC FOUNDATION. REINFORCE WITH 2 -k -J'" L TE (BOLTED TO BEAM) SHEET N O. O y4 REINFORCING BARS THICKEN SLABS BENEATH BEARING WALLS AND COLUMNS. °. SHIMS TO LEVEL BEAM REINFORCE FOOTING WITH (2) #4 REINFORCING BARS. 3" MINIMUM BEARING SURFACE FOR WOOD BEAM GARAGE DOOR BLOCKOUT * "I Q r iwa W BEAM POCKET ,s i Lu \ It Z 072.5 AR�FEss10 P�, i 1 M C H GENERAL NOTES WIND FRAMING NOTES NAILING SCHEDULE PLAN CONTENTS: Design Services 1).RIDGE-TO-RAFTER ASSEMBLY: ROOF FRAMING: OCCUPANCY CLASSIFICATION R3 RESIDENTIAL 1-1/4"x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4. NAIL NAIL NOTES BUILDING USE RESIDENTIAL DWELLING JOINT DESCRIPTION When a collar tie is used in leu of a ridge strap,the number of lOd common nails required QTY. SPACING in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap. BUILDING HEIGHT (SEE PLANS) CONSTRUCTION NOTES: p RAFTER TO B'WALL-3-8d COMMON EACH TOE-NAIL 1).The information within this set of construction documents is related to basic design 2).RAFTER-TO-WALL ASSEMBLY: TOP PLATE 10'WALL:4-8d COMMO RAFTER TOTAL SQ.FT.OF CONSTRUCTION (SEE PLANS) www.mchdesignservices.com intent and framing details.They are intended as a construction aid,not a substitute Lateral framingand shear wall connections for rafter,ceiling or truss to to late shall be in CEILING JOIST 8'WALL:3-8d COMMON EACH DESIGN CRITERIA(UNIFORM CODE g P P TOE-NAIL ) 2020 IRC,2020 NYS UNIFORM FIRE PREVENTION AND BUILDING CODE phone: for generally accepted good building practice and compliance with current New York accordance to table 3.3.When a raker or truss do not fall in line with studs below,rafters TO TOP PLATE 10'WALL:4-8d COMMO JOIST AS PER FLOOR PLANS,CROSS SECTION,DETAILS,AND GENERAL NOTES (631)298-2250 State building codes.The General Contractor is responsible for providing standard or trusses shall be attached to the wall top plate and the wall top plate shall be attached to CEILING JOIST TO AS PER TABLE 3.7 EACH FACE FRAMING ELEMENTS construction details and procedures to ensure a professionally finished,structurally the to the wall stud with uplift connections.Roofs overhanging the rake side of the building PARALLEL RAFTER WFCM-SBC LAP NAIL DESIGN LIVE LOAD(PSF)R301.5 DESIGN DEAD LOAD(PSF)R301.2.2.2 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS R301.7 UNINHABITABLE ATTICS(NO STORAGE) 10 EXTERIOR(LIGHT FRAME)WOOD WALLS 15 RAFTERS GREATER THAN 3:12 PITCH L/180 sound and a weatherproof completed product. shall be connected with uplift connections in accordance with table 33c. CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE UNINHABITABLE ATTICS(STORAGE) 20 EXTERIOR(LIGHT FRAME)STEEL WALLS 14 (NO FINISHED CEILING) email: 2).The General Contractor is responsible for ensuring that all work and construction 3).WALL OVER PARTITION WFCM-SBC LAP NAIL HABITABLE ATTICS AND INTERIOR(LIGHT FRAME)WOOD WALLS 10 INTERIOR WALLS AND PARTITIONS W80michael@mchdesignservices.com meets current federal,state,county and local codes,ordinances and regulations,etc. Wall studsds above LL bovASSEMBLY:e and studs below a floor level shall be attached with uplift connections in COLLAR TIE AS PER TABLE 3.4 EACH FACE ATTICS WITH FIXED STAIRS 30 INTERIOR(LIGHT FRAME)STEEL WALLS 5 FLOORS U360 These codes are to be considered as part of the specifications for this building and accordance with table 3.3b.When wall studs above do not fall in line with studs below,the TO RAFTER WFCM-SBC END NAIL EXTERIOR BALCONIES AND DECKS 40 MASONRY WALLS(8"THICK) BO CEILINGS(PLASTER STUCCO) U360 should be adhered to even if in variance with the plan. studs shall be attached to a common member in the floor assembly with uplift connectors in BLOCKING EACH TOE FIRE ESCAPES 40 CONCRETE WALLS(6"THICK) 85 CEILINGS(GYPSUM) L/240 accordance with table 3.3. TO RAFTER 2-8d COMMON END NAIL GUARDS AND HANDRAILS 200 SIP WALLS 10 ALL OTHER STRUCTURAL MEMBERS U240 3).Dimensions shall take precedent over scaled drawings. RIM BOARD END EXTERIOR WALLS GUARD IN-FILL COMPONENTS 50 EACH VEHICLE GARAGES(R301.5)PER 20 SQ.IN.20001bs (PLASTER,STUCCO) H/360 NOT SCALE DRAWINGS). 4).WALL ASSEMBLY TO FOUNDATION: TO RAFTER 2-16d COMMON PASSANGER VEHICLES 50 EXTERIOR WALLS(BRITTLE FINISHES) H/240 NON-SLEEPING ROOMS END NAIL First wall studs shall be connected to the foundation,sill plate,or bottom plate with uplift 40 EXTERIOR WALLS(FLEXIBLE FINISHES) H/120 4).The designer has not been engaged for construction supervision and assumes no connectors.Steel straps shall have a minimum embedment of 7 inches in concrete WALL FRAMING: SLEEPING ROOMS 30 responsibility for construction coordinating with these plans,nor responsibility for foundation and slab-on-grade,15 inches in masonry block foundations,or lapped under LINTELS(SUPPORTING MASONY WALLS) 1)600L NAIL STAIRS 40 construction means,methods,techniques,sequences,or procedures,or for safety the plate and nailed in accordance with table 33NAI b.When steel straps are lapped under the JOINT DESCRIPTION NAI NOTES ROOF GROUND SNOW LOAD 20 precautions and programs in connection with the work.There are no warranties for a bottom plate,3 inch square washes shall be used with the anchor bolts.Anchor bolt QTY. specific use expressed or implied in the use of these plans. spacing is to be spaced and sized in accordance to table 3.2a.In addition to spacing, TOP PLATE TO PER FACE NAIL EXPOSURE CATAGORY (DESIGNED FOR EXPOSURE C) anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and all TOP PLATE 2-16d COMMON FOOT SEE NOTE:1 LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION 5).Refer to the Window and Door schedule for exterior openings. corners. TOP PLATES AT JOINTS FACE ROOF-FOUNDATION DETAIL PAGE&GENERAL NOTE PAGE ^ INTERSECTIONS 4-16d COMMON EA.SIDE NAIL NAILING SCHEDULE 6).The General Contractor is to ensure that masonry or prefabracted fireplaces meets 5).TYPE 1 EXTERIOR SHEARWALL CONNECTIONS: SEE GENERAL NOTE PAGE or exceeds manufacture's specifications and applicable codes. T STUD TO 24" FACE p pp Type I exterior shear walls with a minimum of 7/16 inch wood structural panel on the exterior STUD 2-16d COMMON EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE attached with Bid nails at 6"o.c.at the panel edges and 12"o.c.in the field,and O.C. NAIL S m.: 7).The General Contractor is to consult with the owner for all built-in items 1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7"o.c.at panel HEADER TO 16"O.C. FACE FIRE PROTECTION Y SMOKE ALARMS TO COMPLY WITH NEPA 72 AND NYS R314 NYS. such as bookcases,shelving, ant closets,trims,etc. edges and 10"o.c.in the field shall be in accordance with the length requirements specified HEADER 16d COMMON ALONG EDGES NAIL SMOKE&CO2 DETECTORS Sl CARBON MONIXIDE ALARMS TO COMPLY WITH R315 NYS. pantry, in table 3.15a-b. TOP OR BOTTOM 2-16d COMMONTRUSS DESIGN PER 2x4 STUD END N/A-STANDARD STICK FRAME CONSTRUCTION 8).Wind load requirements shall be taken into account during construction. 6).TYPE II EXTERIOR SHEARWALL CONNECTIONS: PLATE TO STUD 3-16d COMMO PER 2x6 STUD NAIL ENERGY CALCULATIONS 2020 ENERGY CONSERVATION CONSTRUCTION CODE NYS 19 NYCRR PART 124 O FOUNDATION NOTES: Type II exterior factorin ashall meet the requirements of table 3.15a-b times the appropriate BOTTOM PLATE TO:FLOOR JOIST,BAND JOIST, 2-16d COMMO PER FACE NAIL CLIMATIC & GEOGRAPHIC DESIGN CRITERIA length adjustment factors in table 3.16. 1).The General Contractor and Mason to review plans,elevations,details and notes to END JOIST OR BLOCKING FOOT SEE NOTE:1,2 SEISMIC FROST WINTER determine intended heights of finished floorGROUND WIND ICESHIELD s)above typical grade. 7)-INTERIOR SHEARWALL CONNECTIONS: FLOOR FRAMING: SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT FLOOD Allowable sidewall lengths provided in table 3.14 shall be permitted to be increased when LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED HAZARDS NAIL NAIL 2).All footings to rest on undisturbed(virgin)soil. interior shearwalls are used.Sheathing and connections shall be in accordance with JOINT DESCRIPTION NOTES • 2.4.4.2 and 2.2.4 respectively. QTY. SPACING MODERATE SLIGHT TO �/+ 20 PSF 130 B SEVERE 3 FT. 17 NONE Cn 3.Provide 1/2"expansion joint material between concrete slabs and abutting JOIST TO: PER TOE TO HEAVY MODERATE - concrete or masonry walls occuring in exterior or unheated interior areas. 4-Sd COMMD 8).CONNECTIONS AROUND onsshaEXTERIOR WALL edwithupl SILL,TOP PLATE OR GIRDER JOIST NAIL ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: Header and/or girder connections shall be attached with connectors connections in accordance BRIDGING EACH TOE O 4).Any new concrete walls being attached to existing concrete structure shall with table 3.5.Window sill plates shall be have steel connectors in accordance with table TO JOIST 2-8d COMMON END NAIL NAIL SPACING NAIL SPACING AT INTERMEDIATE /� F'7� 0 be installed with#5 re-bar,18"long at 12"o.c..Use approved epoxy for installation. 3 5 SHEATHING LOCATION AT PANEL EDGES SUPPORTS IN THE PANEL FIELD NOTES ` I 5).Unless otherwise noted,all slabs on rade to be 3000 BLOCKING 2-Sd COMMON EACH TOE g mesh r.Concrete to be TO JOIST END NAIL 4'PERIMETER EDGE ZONE 8d COMMON poured on 4 inch thick sand or gravel fill with 6x6 wire mesh reinforcing.Interior slabs 9).CATHEDRAL CEILING ASSEMBLY: @ 6"O.C. 8d COMMON @ 6"O.C. SEE NOTES:13 A, to be minimum 3-1/2 inch thick.All fill to be compacted to 95%relative density with Where a ridge is to be used as a structural beam,the rafters shall either be notched and BLOCKING TO: 3-16d COMM) EACH TOE INTERIOR ZONE 8d COMMON @ 6"O. 8d COMMON O.C. SEE NOTES1(BOTH FIELDS) ` v 6"maximum lifts(layers). anchored on top of the beam or slope connectors shall be attached to each rafter-to-ridge SILL OR TOP PLATE BLOCK NAIL @ 12" :attached with the above requirements. 3-16d COMMD NOTE:2 FOR PANEL FIELD O 6).Crawl spaces to be provided with a minimum 18"x24"access opening.Install one along the open ceiling part of the building.Connections to the ridge and wall shall be be LEDGER STRIP EACH FACE GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON @ 4"O. 8d COMMON @ 4'O.C. SEE NOTES:1,3 W 8x16 cast iron foundation vent for every 150 sq.ft.of area. q TO BEAM JOIST NAIL DECK AND COVERED PORCH NOTES: II�� JOIST ON LEDGER 3-8dCOMMD 1�-1 7).Dampproof exterior of foundation with bituminous coating as required by current TO BEAM JOIST NAIL PER TOE NOTES � O N.Y.S.Residential Construction Code.A 6-mil polyethylene film shall be applied over 1).Unless otherwise noted,all framing material to be#1 ACQ pressure treated lumber. THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. 1� the below grade portion of exterior walls prior to backfilling. All fasteners,hangers and anchors to be galvinized or stainless steel. BAND JOIST 3-16d COMM. PER END TO JOIST JOIST NAIL 1).For roof sheathing within 4 feet of the perimeter edge of the roof,including 4 feet on each side of the roof peak, O a 8).Drainage az required by current N.Y.S.Residential Construction Code. 2).Girders for deck joists to be bolted to each post with washers and nuts. BAND JOIST TO: PER TOE NAIL the 4 foot perimeter edge zone attachments required shall be used. P SILL OR TOP PLATE 2-16d COMMD FOOT SEE NOTE:1 P g q O FRAMING NOTES Girders on concrete piers shall be anchored with proper steel connectors anchored into concrete with a minimum 1/2"dia x 7"long anchor bolt with washers and nuts. I 2).Tabulated 12 inch o.c.nail spacing assumes sheathing attached to rafter/truss framing members with G>0.49. C) g q prescriptive g g NAIL "NAIL For framing members with<0.42<G<0.49,the nail spacing shall be reduced to 6 inches o.c Q O 1 .All framing techniques and methods as rescri tive desi n of current SBC High Wind 3).Posts supporting girders shall be anchored to a 12"x12"x12"thick concrete footing. JOINT DESCRIPTION Q O Edition Wood Framing Construction Manual. QTY. SPACING Use a minimum 1/2"dia x 8"long anchor bolt with washers and nuts.Footings Shall be 3 k. 3).Tabulated 4 inch o.c.nail spacing assumes sheathing to rafter/truss framing members with G>0.49.For 2).Unless otherwise noted,all framing and structural wood material to be#2+BTR. below grade.Porches with covered roofs shall have 12"dia.concrete piers for the girders. STRUCTURAL PANEL Bid AS PER TABLE 3.3 framing members with 0.42<G<0.49,the nail spacing shall be reduced to 3 inches o.c. WFCM-SBC WALL SHEATHING REQUIREMENTS FOR WIND LOADS: e U Douglas Fir. 4).Deck joists to have blocking at 8'0o.t.. CEILING SHEATHING: Er.� SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES r ^ UJ 3).Floors.walls,ceilings and rafters to be spaced at 16 inches o.c.unless noted 5).A minimum of 10 inch flashing shall be installed between the building and ledger. NAIL NAI_ AT PANEL EDGES SUPPORTS IN THE PANEL FIELD `/ ' otherwise. Ledger to be fastened to building with 1/2"dia.bolts with washers and nuts JOINT DESCRIPTION QTY. SPACING 4'EDGE ZONE 8d COMMON @ 6"O. . 8d COMMON @ 12"O.C. SEE NOTES:1,3(BOTH FIELDS) where needed. GYPSUM 7" O.C.EDGE NOTE:2 FOR PANEL FIELD V v 4).Unless otherwise noted,all bearing wall headers to be(2)2x10#2+BTR.Doug.Fir. Sd COOLERS O Bearing wall headers to have(2)jack studs and(2)full length studs on each side of all WALLBOARD 10"O.0.FIELD INTERIOR ZONE 8d COMMON @ 6"O.C. d COMMON @ 12"O.C. SEE NOTE:3 r^ openings.LVL headers to have(3)jack studs and(2)full length studs on each side of 6).Concrete piers shall be a minimum 6"above grade. openings.Bearing wall window sills shall also have(2)window sill plates for 2x4 wall WALL SHEATHING: NOTES openings between 4'1 and 6'0 and 2x6 wall openings between 5'll and 8'9.Provide fire 7).All joists to be supported with hangers and anchors.Each Joist shall also be anchored NAIL NAIL to girder(s). THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. and blocking where applicable. JOINT DESCRIPTION NAI SPAONG 5).All flush beams/headers to be installed with heavydu 8).Covered Roofs shall be assembled and anchored the same manner as a typical building. STRUCTURAL AS PER TABLE 3.9 h galvinized hangers and 8d COMMO For wall sheathing within 4 feet of the comers,the 4 foot edge zone attachment requirements shall anchors where applicable to all connecting joists. PLUMBING NOTES PANELS WFCM-SBC be O be used. 7/16"OSB 6d COMMON 3"O.C.EDGE 6).Double up floor joists under walls that run parallel to the Floor joist and under bathtu PLYWOOD 6"O.C.FIELD. 1).All water supply,drainage and venting to be installed as per N.Y.S.Residential 2).Tabulated 12 inch o.c.nail spacing assumes sheathing attached to stud framing members with Floors to have ceramic tile installed shall be verified for proper load capacity unless noted Construction Code. GYPSUM7" O.C.EDGE G>0.49.For framing members with 0.42<G<,the nail spacings shall be reduced to 6 inches o.c. on plans. WALLBOARD Sd COOLERS 10"O.C.FIELD 7).Provide 2-1-3/4"thick microlams(height to match floor joists)around stairwell and/ r 2).Verify septic system with the Engineer for Suffolk County Health Department approval. 3).For exterior panel siding,galvinized box nails shall be permitted to be substituted for common nails. other access openings unless otherwise noted(typical). FLOOR SHEATHING: 3).If wall studs,plates or joists are cut out during installation for any plumbing related work, NAIL NAIL 8).Dormers running up roof rafters are to be supported by double rafters on either side provide adequate bracing and plates to protect and secure the structure.Verify with the JOINT DESCRIPTION QTY. SPACNG 1).PROVIDE 5/8'TYPE-X SHE FIRE STOPPING AT 100 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS. where applicable unless otherwise noted. state code and manufacture's recommendation for maximum hole size and spacing permitted. z).USE nMPsoN HANGERS AND No ANCHORS WITHz-MAx TRIPPLE PROTECTIVE COATING Folz CONTACT WITH ACQ. STRUCTURAL PANELS 6"O.C.EDGE EGRESS OPENINGS MIN.5.0 SQ GRADE FLOOR 3).INSTALL 1-Co2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR 1"OR LESS 8d COMMO 12"O.C.FIELD (5.7 SQ.FT.2ND.FLOOR) 9).Provide blocking/bridging in floor joists at 8'0 o.c..Use solid blocking in floor joists HVAC SYSTEM NOTES M(5.7S SILL-AFF under all bearing walls. 1).Mechanical subcontractor is responsible for adhearing to all applicable codes and safety NOTES: NYS Residential Code R302.11-FIREBLOCKING REQUIRED o 10).Provide insulation baffles at eave vents between rafters.Install draft blocking az requirements.' Fireblocking shall he provided to cut ff.[]concealed draft openings(both vertical and horizontal)NOTE: and to form an effective fire barrier between stories,and between a top story and the roof space. needed. THESE NOTES ARE ONLY TO BE REFERRED TOT CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY Firebloddng shall be provided in wood-frame construction in the following locations. 2).HVAC subcontractor is to fully coordinate all system data and requirements with the MENTIONED IN SCHEDULE NOTES ONLY. EXISTING CONDITIONS.MINIMUM 3000#CAPACITY. In concealed spaces of stud walls and partitions,including fumed rred spaces,at the ceiling and floor 11).Unless otherwise noted,all roofs and walls to have a minimum 1/2"thick,4-ply Fir equipment supplier. 1).levels.Concealed horizontal fumed spaces shall also be flreblorked at Intervals not exceeding 10 1).Nailing requirements are based on wall sheathn feet.Batts or blankets of mineral or glass fiber shall be allowed as fireblocking in walls constructed CDX exterior sheathing grade plywood.Plywood to cover over plates and headers. 3).HVAC subcontractor to provide final g SOIL COMPACTION: using parallel rows of studs or staggered studs. p system layout drawing and submit it to the General nailed 6"on-center at the panel edge.If wall sheathing 12).Unless otherwise noted use 3/4"thick T&G PTS Fir or Advantech plywood subfloor Contractor and owner for final review and approval. is nailed 3"on-center at the panel edge to obtain higher 1).NEW FILL TO BE CLEAN OF ORGANIC MATERIAL CONTRACTOR 2).At all interconnections between concealed vertical and horizontal spaces such as occur at softs. R M shear capacities,nailing requirements for structural TO VERIFY EXISTING SOIL CONDITIONS PRIOR TO FILL drop ceilings and cove ceilings. DRAWN AWN BY: 1-1 H adhered with PL400 adhesive and screwed to floor joists.Finished floor to be installed ELECTRICAL NOTES: REMOVE AND ADD ADDITIONAL EILL ONS PRIOR over subfloor as per manufactures instructions. members shall be doubled,or alternate connectors, 3).In concealed spares between stair stringers at the top and bottom of the run.Enclosed spaces such as shear plates,shall be used to maintain load p ath' 2).COMPACTION OF NEW FILL SHALL BE AT LEAST 95%PROCTOR under stairs shall comply with current N.Y.S.Residential Code. 1).All electrical t0 be installed a5 per N.Y.S.Residential Construction Cade. DENSITY(PER AS D 698 AND AAM D 1557).COMPACT THE 13).All bathroom walls to have 1/2"thick moisture-resistant sheetrock.Garage walls and SOIL AT 12'LIFTS(TYPICAL).CONTRACTOR TO HAVE FILL 4).At openings around vents•pipes and ducts at ceiling and floor level•to resist the free passage of 9/25/2021 ceilings and over furnace to have 5/8"thick type-x sheetrock.All other parts of building 2).All electrical work shall be approved by a qualified Underwriter. 2).When wall sheathing is continuous over connected TESTED BY A PROFFESSIONAL AGENCY FOR COMPACTION, flame and products of combustion. to have regular 1/2"sheetrock.All walls to be taped and finished. members,the tabulated number of nails shall be permitted 3).DO NOT BACKFILL UNTILL FIRST FLOOR DECK CONSTRUCTION. 5.For the flreblockin or to be reduced tol-16d nail ) g chimneys and fireplaces,as required by cu ent N.Y.S.Residential Code. 3).All electrical Work t0 comply Wlttl 2014 NEC. per foot. INCLUDING SUBFLOOR,IS COMPLETE. 14).All roof with a pitch less than 4:12 shall be installed with an Ice&Water barrier or approved equal.Flat roofs shall be applied with a Fiberglas base sheet with an EPDM 4).Install Smoke detectors and Carbon Monoxide detectors throughout as per section R314 SCALE: SEE PLAN torch down type material over. and R315 of IRC. 16).All sill plates and wood in contact with concrete to be pressure treated.Sill plates to EXTERIOR FIBERGLASS COLUMNS TO BE HB&G be installed with a foam sill gasket and cop-r-tex termite shield or approved equal. OR APPROVED EQUAL.INSTALL WITH CAP AND BASES.USE WITH FLASHING CAPS TO COVER TOP L SHEET N O: r sue W Irv% Y, 2 , /'r,.,r C2 0725')2 pROFES SOON