Loading...
HomeMy WebLinkAbout47141-Z OSUFfat p Town of Southold 2/15/2022 0 t P.O.Box 1179 5 - 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42796 Date: 2/15/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: . 1155 Jasmine Ln., Southold SCTM#: 473889 Sec/Block/Lot: 69.-3-24.4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/9/2021 pursuant to which Building Permit No. 47141 dated 11/23/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels to existing single-family dwelling as applied for. The certificate is issued to Rolle,Michael of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47141 1/12/2022 PLUMBERS CERTIFICATION DATED 9 � (—N I? 0 JA'Wthqfizpd Signature �suFeoc��o TOWN OF SOUTHOLD BUILDING DEPARTMENT a - TOWN CLERK'S OFFICE ca "oy • �� SOUTHOLD, NY poi Sao BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47141 Date: 11/23/2021 Permission is hereby granted to: Rolle, Michael 1155 Jasmine Ln Southold, NY 11971 To: install roof-mounted solar panels to existing single-family dwelling as applied for. At premises located at: 1155 Jasmine Ln., Southold SCTM #473889 Sec/Block/Lot# 69.-3-24.4 Pursuant to application dated 11/9/2021 and approved by the Building Inspector. To expire on 5/25/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 B it pector pV SOOT'®l 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 , �Q sean.deviin(aD-town.southold.ny.us Southold,NY 11971=0959 ®l�c®U�9�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Michael Rolle Address: 1155 Jasmine Ln city:Southold st: NY zip: 11971 Building Permit#: 47141 section: 69 Block: 3 Lot: 24.4 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Element Energy LLC License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 7.22kW Roof Mounted PV Solar Energy System w/ (19) Qcell Qpeak Duo ML-G9 380W Modules, Enphase IQ3 Combiner w/220x2 215x1, PV AC Disconnect Notes: Solar Inspector Signature: �� Date: January 12, 2022 S.Devlin-Cert Electrical Compliance Form OE SOUIho� 9 -7191 ! IS�r jj+SM /IV g:j I—JY # # TOWN OF SOUTHOLD BUILDING`DEPT: 765-1802 INSPECTION [ ]` FOUNDATION 1ST [ ] ROUGH PLBG.`, [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION- [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) / ELECTRICAL (FINAL) [ ] CODE VIOLATION [/ ] PRE C/O REMARKS: Yov ov�e �'&Wv4� t 'A 1,5-77LOA^fir,� L Opt Ic- 4' DATE I Z ZZ INSPECTOR ,moo �o # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ]' FOUNDATION 2ND - [ .- INSULATION/CAULKING [ ] FRAMING /STRAPPING [ FINALgbLnlZ- [ ] -FIREPLACE & CHIMNEY [ ] FIRE SAFE=TY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: Oc&44 GtA 6,u/ 5v(ov. Ak, n DATE �o I X22 INSPECTOR p, FIELD:INSPCTIUI4:REP(StT•. DATE.:. CO.MMNTS FOUNDATIONOST) 'y M, --. -------------- -- --- -- 11' C40 FOUNDATION: • Z ROUGH FItQMING Be �r y l PLUMBING' INSULATION•P-ER N.-Y. NE . y. STATE ERGY CURE rA FINAL Z ADDITIONALCOMn'IENTS 1 O V� �. MAY..:. .:�: : ' MIL't Q* TOWN OF SOUTHOLD —BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. 0. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtomLrmy.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only EC E � V PERMIT NO. Building Inspector: ij ,.Appkatior�-�nd io`rms','�nust--�6-f�ii'le'd,'o�'u"t�i'n"th'ei'r'ji�ntitL:it --In, pqTpl e q. BUILDING DEPT -aopli'c'a.tioris,wiil'n'o'tbe"ac'c'Opted. Wher6 the Applicant isihbi the owneri,an. I=SOUTHOLD TOWN 0 M ete :'OWner't Aiithokz�ii6n f6r 2)shall,be c6 I d D at e: OWNER(S PFTR0PlERTY1.-1 Name: 0 SCTM# 10 00- e 6-96V 0- 3 C-)&-0- Project Address: Phone#: —------J�1-1-77 el--- .7,!Pf--5 �=7a //,-T Mailing Address: 'CONTACT PERSON:` Name: Mailing Address: 47 .a CA -4y,L Phone#: Email: -,DESIGN,PROFESSf6NAL,INFORMATION: Name: Mailing Address: Phone#: 'CONTRACTOR INF6RMATION: Name: Mailing Address: Phone#: Email: DIESCMIPTON OF,1PRb1POSED:CbNSTRUCTlON-,- . E]NewStructure ElAddition ElAlteration EIRepair ElDemolition Estimated Cost o Project: E�Qther fe-/ -ft /7/ $ Will the lot be re-graded? F-]Yes No Will excess fill be removed from premises? El��No wnv.�iyn uwun icniv..�..i�..onvo•fi•rvI ov\AJf-Ur-L r-L/or\/IVIIJ/D V 1 LO L VV riouIVI V u PROPERTY INFORMATION Existing use of property: Alev?441 Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes o IF YES, PROVIDE A COPY. 171Check BOX After Reading The owner/contractor/design professional is responsible for all drainage:and stbrin water issues as provided by Chapter 236 of the Town Code.:,APPLJCATION`IS.HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold;Suffolk,County,NewYork and other applicable laws;Ordinances or Regulations,for fhe.wnstructlon of-.buildings, alterations or for:iemoval or demolition as herein described.The applicant agrees,to comply with all applicable laws;ordinances,-building code,' . housing.cade,and regulations and to admit authorized inspectors on premises and in buiiding(s)for necessaryinspections.False statements made herein are punlshable'as:a�Class A misdemeanor pursuant to Section230AS of the New York State Penal Law. Application Submitted By(print name): AuEhorized Agent .1]Owner Signature of Applicants STATE OF NEW YORK) SS: COUNTY OF J, e/�' being duly sworn, deposes and s that says he is the applicant Y ( ) pp t (Name of individual signing contract)above named, (S)he is.the (Contractor, Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of_- ) MA'Yl r_. iX .20 C.J Notary Public DEBRA A SEPULVEDA NOTARY PUBLIC,STATE OF NEW YOR>(.. -._ Rc*ftWnNoa'OISFAI269!PROPS Y OWNER AUTHORIZATION_ Wher _the applicant is not the owner) My Cominlalon Expims � 1 /v r I, i:'V' 'liz!,el_��' "�-- at residingJ ��fl'�'1/ �� /� do hereby authorize f" 'L to apply on my behalf to the Town of Southold Building Department for approval as described herein. Y. Owner's Signature Date ell Print Owner's Name 2 Suf.F UILDING DEPARTMENT-'Electrical Inspector. TOWN OF SOUTHOLD o 0 U To II Annex - 54375 Main Road - PO Box 1179 o • �Q�1 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 _southoldtownny.gov - seand(aD-southoldtownny.gov N AP Ll oATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: ' Z-,(G Electrician's Name: , License No.: SoZG � Elec. email: �,11// re2�=r s. l Elec. Phone No: ❑I request an email copy of Certificate of Compliance Elec. Address.: CtiWAV 15�e ,iii /J JOB SITE INFORMATION (All Information Required) Name: /G. 6:zlle Address: ,e ,, Avy Cross Street: Phone No.: Bldg.Permit #: email: Tax Map District: 1000 ection: de;PC/ao Block: 3 000 Lot: _;PL YIja BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES MNO 0 Rough In ❑ Final Do you need a Temp Certificate?: . ❑ YES r, NO Issued On Temp Information: (All information required) Service Size❑1 PhF—]3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 FJ2 H Frame Pole Work done on Service? p Y MN Additional Information: PAYMENT DUE WITH APPLICATION 00. ,, - I , I r I ` — ` S,� Loo"�4c NYSI F New York State Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE, NEW YORK 11747-3129 I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) T J ^^^""" 823336604 ROBERT S FEDE INSURANCE AGENCY ' 23 GREEN ST STE 102 R HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 706281 07/13/2021 TO 07/13/2022 7/15/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS'. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. i NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:438572026 U-26.3 vTAT Workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a. Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1 c. Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 823336604 2. Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Main Rd 3b. Policy Number of Entity Listed in Box"l a" Southold, NY 11971 DBL567527 3c.Policy effective period 01/01/2021 to 12/31/2022 4. Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. F1 B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/15/2021 By (W1 I t (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. D13-120.1 (10-17) I I Piiiiiiiiiiiiiiiiiiiiiiiiuiiiiiiiiiiiiu°IIIIII CERTIFICATE OF LIABILITY INSURANCE DATE(MM7/15/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS. FEDE INSURANCE AGENCY PHONE - - FAX - - 23 GREEN STREET,SUITE 102 E-MAIL Alc Ext: AIC No L HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSURERS AFFORDING COVERAGE NAIC# INSURER A: INSURED INSURER B:STATE INSURANCE FUND 523930 Element Energy LLC INSURER C:SHELTER POINT POINT— _BT432F_ ELEMENT ENERGY SYSTEMS INSURER 0: 7470 SOUND AVENUE INSURER E MATTITUCK, NY 11952 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE POLICY NUMBER MM/DD/YYYY) (MMIDDIYYYYI LIMITS COMMERCIAL GENERAL LIABILITY X X CL00275204 7/14/2021 7/14/2022 EACH OCCURRENCE $ 3,000,000 CLAIMS-MADE OCCUR DAMAGE TO ED PREM SES a ocou".nce $ 100,000 A MED EXP(Any one person) $ 5000 IMA389203 7/14/2021 7/14/2022 PERSONAL&ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 3,000,000 POLICY 7 PRO- F—]JECT LOC PRODUCTS-COMP/OP AGG $ 3000000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY Per accident $ AUTOS ONLY AUTOS ( ) HIRED r $ NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY Per accident $ UMBRELLA LAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ g WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N 124494445 X STATUTE ER ANY PROPRIETORlPARTNER/EXECUTIVE 7/13/2021 7/13/2022 B OFFICER/MEMBER EXCLUDED? N/A E.L.EACH ACCIDENT $ 1,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ 1,000000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL _T DBL567527 1/01/2021 1/01/2022 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Rd THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Southold NY11971 AUTHORIZED REPRESEN�TAMVE 1RO&-rt-S. Fede, ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD b CV APPRO ,ED AS NOTED DATE: v�-' (B.P.# � FEE: BY:-LE�: NOTIFY BUILDING DEPARTMENT AT . 765-1802 8 AM TO 4 PM FOR THE ELECTRICAL FOLLOWING INSPECTIONS: WSPECTION R(EOUIREID 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF ut u .t SeUTIII,)�m,T8WN41LAftG BOARD Sq jT STEES N.Y.SS DF — OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA .0F OCCUPANCY Zoho Sign Document ID:HOUWDBLJRCFKNDICCASW6TRPNYYFIXJVJCWiGUGVBTC Town of Southold November 3rd, 2021 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Rolle Residence,1155 Jasmine Ln, Southold, NY 11971 To Town of Southold: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NFPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.5 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, ,C�OF N&JV Gennaro Anthony Giustra. P.E. �0 A G, 0 Great Eastern Services, Inc. PO Box 240 24 Harvey Rd — w r ' � Riverhead, NY 11901 X03443 Office: 631.543.9555 10 103 SIONP� Mobile: 631.235.0189 Email: jerrygiustra@gmail.com ----------- - powered by i OUO I `_TOP-BRAND PV--1 EUROPE 2020 Warranty 0 CELLS Product B Perrormame Yield Security BREAKING THE 20%EFFICIENCY BARRIER � Ip J Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.6%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID Technology',Hot-Spot Protect and Traceable Quality Tra.QM. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(6000 Pa)and wind loads(4000 Pa). �g A RELIABLE INVESTMENT Q�rAp�� Inclusive 25-year product warranty and 25-year 1 linear performance warrantyz. STATE OF THE ART MODULE TECHNOLOGY r - Q.ANTUM DUO combines cutting edge cell separation and innovative 12-busbar design with Q.ANTUM Technology. APT test conditions according to IEC/TS 62804-1:2015,method B(-1500V,168h) 1 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: (110 Rooftop arrays residential buildings Engineered in Germany OCELLS r o MECHANICAL SPECIFICATION Format 72.4 in x 40.6 in x 1.26 in(including frame) 72`` omm) (1840 mm x 1030 mm x 32 mm) 42.9-(1068 mm) 15.0'(376 mm) Weight 43.0 lbs(19.5 kg) i aQ..z'ruoomm) Front Cover 0.11in(2.8 mm)thermally pre-stressed glass with anti-reflection technology 4xGro-ng Pointeo018-(4.5mm) Back Cover Composite film 38.6'98 mm) Frame Black anodized aluminum ® 4le•(lo3o mm) Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in .472'(1 00-) (53-101mm x 32-60 mm x 15-18 mm),IP67,with bypass diodes -L_� e.omm4aanala4 Cable 4mm2 Solar cable;(+)>_47.2in(1200mm),(-)>_47.2in(1200mm) 4x Maum09 IM,(DETAIL A) b Connector Staubli MC4;IP68 -.f 126.r3z mm) DETAIL o.e3•(]e mm) I-I 0.96'(245mm)T�I0.33'(B.bmm) ELECTRICAL CHARACTERISTICS j POWER CLASS 365 3ZO' 375 380. 385 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-OW) Power at MPP' PMPP [W] 365 370 375 380 385 E Short Circuit Current' Ise [A] 10.40 10.44 10.47 10.50 10.53 Open Circuit Voltage' Voc [V] 44.93 44.97 45.01 45.04 45.08 r Current at MPP IMPP [A] 9.87 9.92 9.98 10.04 10.10 Voltage at MPP VMPP [V] 36.99 37.28 37.57 37.85 38.13 Efficiency' rI 1%1 >!19.3 ?19.5 119.8 2:20.1 2020.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT] Power at MPP PMPP [W] 273.3 277.1 280.8 284.6 288.3 E Short Circuit Current Ise [Al 8.38 8.41 8.43 8.46 8.48 E Open Circuit Voltage V. [V] 42.37 42.41 42.44 42.48 42.51 c Current at MPP IMPP [A] 7.76 7.81 7.86 7.91 7.96 Voltage at MPP VMFP [V] 35.23 35.48 35.72 35.96 36.20 'Measurement tolerances PMPP±3%;Isc;Voc±5%at STC:1000W/ml,25±2°C,AM 1.5 according to IEC 60904-3.2800 W/m2,NMOT,spectrum AM 1.5 f Q CELLS PERFORMANCE WARRANTY - PERFORMANCE AT LOW IRRADIANCE " y...Sao DDELL60 110 --r--`- r----------1-----� At least 98%of nominal power during first year.Thereafter max.0.5% = I I I og .6 ------------------------------ degradation per year.At least 93.5% V-- --L_____L W Q of nominal power up to 10 years.At z z least 86`y of nominal power up to ? a� oa ------------- 25 years oa --------------i------li-----� a KZ g Z 01 as All data within measurement toleranc- ¢ i es.Full warranties In accordance with w B0 :I Roo eoo eoo loon the warranty terms of the Q CELLS o C) o sales organisation of your respective IRRADIANCE[WI.-] U a° ]o country. �. YEARS Typical module performance under low irradiance conditions in m MY+`tN v,ce+.lv s A36 W u 5,s�im_n1<I comparison to STC conditions(25'C,5000 W/m2) TEMPERATURE COEFFICIENTS' Temperature Coefficient of I c //K +0.04 Temperature Coefficient of V P Ise [° 1 P oc p [%/K] -0.27 � Temperature Coefficient of PMPP y [%/K] -0.35 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) 0 Q PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vsys [V] 1000(IEC)/1000(UL) PV module classification Class II o N Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 W Max.Design Load,Push/Pull3 [lbs/ft2] 84(4000 Pa)/55(2660 Pa) Permitted Module Temperature -40°F up to+185°F o Max.Test Load,Push/Pull' [lbs/ft'] 125(6000Pa)/84(4000IDS) on Continuous Duty (-40°C up to+85'C) o 3See Installation Manual U QUALIFICATIONS AND CERTIFICATES PACKAGING AND TRANSPORT INFORMATION 0 61730,CE-compliant, E IEC 61215:2016, IEC 61730:2016, SA® /� ®I O U.S.Patent No.9,893,215 r (` (`� ,u�a5.w,n4 Horizontal 74.41n 42.5in 476in 1458bs 28 24 32 (solar cells) C US packaging 1890mm 1080mm 1208mm 661kg pallets pallets modules Damani _ UL61730 ID tltt]]3]n a N Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved Installation and use of this product. Hanwha O CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAIL inquiryQus.q-cells.com I WEB www.q-cells.us Data Sheet Enphase Microinvertgrs, ° Region:AMERICAS The high-powered smart grid-ready Enphase , Enphase IQ 7 MicroTM and Enphase IQ 7+ Micro" Q 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy', Enphase IQ Battery"',and the Enphase Enlighten"' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) ,C_P Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed ENPHASE 107 Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U *The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com u ENPHASE. ti Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-13-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US %.Commonly used mo4,0:epairings?�, -°,235 W-350 W+ - 235 W _4 W+ _ _'° J Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximumi'npuf`DC voltage - _ 48 U 60 V"--,-' Peak power tracking voltage 27 V-37 V 27V-45V -Operatinci range A -- — 16 V-48 U Min/Max start voltage 22V/48V _ 22 V/60 V f Max DC short circuit cur a t.(module Isc)�' 15 A 15:A' _ �Overvoltage class DC port 11 DC port backfeed current. "�- 7.7-0-A-,^ _ _0 A _ LL ; PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power"- ,; 250 VA 295 VA 1 -- - —Y-- - _ Maximum continuous output power 240 VA 290 VA- f Ndminal(L L)voltage/rangez - 240 V .208V./-.-- 240 V/ 208V/ _ ` 211,,'264V 183-229 V .211-264 V 183 22_9 V `S Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency :, 60 Hz., ` 80,Hz E. Extended frequency range 47-68 Hz 47-68 Hz _ r__ `AC_short circuit fault current over 3'cycles 5.8-Arms 5 8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) _13(240 VAC) 11 (208 VAC)- `Overyoltage clas's AC port: - AC port backfeed current 0 A 0 A Power factor(adjustable) - 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V `Peak`CEC efficiencV,° 976°j° 97.6% 97:6% 97,3% -. CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range 40°C#o•+650C Relative humidity range 4%to 100%(condensing) ___ Connector type(IQ7-60-2=US&IQ7,PLUS72 2-_US) MC4(o_r Amph_enol H4 UTX with additional QDCC-S adapter) { Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable).� Adaptors for modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 -PV2 to UTX:order ECA-S20-S25 LDimensioris•(WxHxD)`-'� . 212 mm x 17-5—m mx Weight 1.08 kg(2.38 lbs) J i.Cooling '_ atura �-Nl convection Nofans;- Approved for wet locations Yesu Pollution degree Enclosure Class II double-insulated,corrosion resistant polymeric enclosure — ---- r----,-__- ---- -----r- - -:--- ---- ---- - — ,,Environmental category/UV-exposure rating yp_ 6/outdoor � NEMAT e � . � •• - FEATURES Communication Power Communication(PLC) Monitoring _ Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means -'The AC and DC connectors hive-6 een evaluated and approved by UL for use'as the load break disconnect'required'by NEC 690: 2. LLL ; ! Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-022.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.Seethe compatibility calculator at https.//enphase.com/en-us/support/module-com ati� ibiiity. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com E N P H AS E. ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. woof 2018-05-24 Zoho Sign Document ID: HOUWDBLJRCFKNDICCASW6TRPNYYFIXJVJCWIGUGVBTC . .; . ,� . ,. ---- —_.._ --- DESIGN i DRAFTING BY: SCOPE OF WORK e`A ELEMENT ENERGY LLC INSTALL A 7.22 KW SOLAR PHOTOVOLTAIC (PV)SYSTEM AT ROLLE RESIDENCE. REVIEW BY J.M.NABCEPCERTIFIE' )GATED AT 1 155 JASMINE LN, SOUTHOLD, NY 1 1 971. Gr _ 051 1 12-129 1E POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. REVISIONS a �j i ria x a Greenport �'.� West Harbor DescRl=10 DATE q x �`s ! z � r;. i .ad pd SYSTEM RATING . pF N � ; Etti a _ kW DC STC ,`P' _RO AG/G ,p £.� 7S �.,�� t .w �•".F,,r,'e�� ` ' Y" 25 �, { EQUIPMENT SUMMARY w Shefter QC Q.PEAK D--', BLK I,',--G9+ 380 WATT PV M0n !'�= Z� — -� �:� Southold '!. a ENPHA5E I07PLU5-72-2-U5 MICRO INVERTERS r�3443 !` CONTRACTOR IRONRIDGE XR100 MOUNTING SYSTEM ` yk ' A�� ss% .4 SHEET INDEX x -` � � _�.. _ ELEMENT ENERGY. LLC PV- COVER �' � nJ kit x _ Peconlc , 1 7470 SOUND AVE PV-2 SITE PLAN 0° MATTITUCK. NY I 195­ p, PV-3 ROOF PV LAYOUT ,' a¢ LICENSE # 43889-1-1 PV-4 STRUCTURAL)DETAILS E SECTIONS LICENSE # 52689-ME PV-5 3-LINE ELECTRICAL DIAGRAM c�, PV-6 LABELS GOVERNING CODES W270°� X90° E 240° v 120° 20 17 NATIONAL ELECTRICAL CODE. 210° 150° PROJECT NAVE 2020 RESIDENTIAL CODE OF NEW YORK STATE. 180° ASCE 7-I I AND LABORATORIES . ` UNDERWRITERS LABORATORIES(UL)STANDARDS Vin 05HA 29 CFR 1910.269 W — GENERAL NOTES PROJECT LOCATION U Q _j 1 . — — 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT BUILDING DEPT LL.1 Lu IAQ z THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE TOWN OF SOUTHOLD F (s) — 7 HIMSELF WITH THE INTENT OF THESE PNS AND MAKE WORK AGREE THE SAME. 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED CZ (� APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, Q INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. W O CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, ; J = AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES 4 ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TOef JURISDICTION. COMMENCING WITH WORK. i ►.�'''� r � — � 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS 1 1 . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE - CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND •' ~ ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND CONTINUE WITH THE WORK, HE SHALL A55UME ALL HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT r �' ■ LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY " ~_ �., i s"LL' NAME 5. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 , SPECIFICATIONS. CONSTRUCTION. COVER /Fp R 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE L G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE r` UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. ! DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING NY5 CODES 4- REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING . CONDITIONS PRIOR TO ORDERING MATERIALS AND ' -.:. DRAWING SCA'.." 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN COMMENCING WITH WORK. r CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S 1 3. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS i. CERTIFICATION OF THESE PLANS. WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON , 1 8.THESE DRAWINGS O ERTY Of THE E OF SERVICE ARE AND A WEEKLY BA515 OK SOONER IF CONDITIONS WARRANT. ,,, !INt itSHEETNJUMBF i I V . I .5 SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE .�►' .` PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE 517E TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCE55 MATERIALS. THE FACILITY 15 TO BE LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE EXTENSIONS TO TH15 PROJECT $ TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF r: : '�4 _ 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL FINAL PAYMENT. AERIAL VIEW PV- EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS RESULT OF HIS WORK. TAX MAP: 1000OG9000300024004 Zoho Sign Document ID: HOUWDBLJRCFKNDICCASW6TRPNYYFIXJVJCWIGUGVBTC LEGEND DESIGN t DKAPTiNG EXISTING UTILITY METER ELEMENT ENERGY LL: MAIN SERVICE PANEL NEW PV SUB-PANELS REVIEW BYO5 I N2BC29 CERTIF'"' A/C DISCONNECT COMBINER INVERTERS GND ELECTRODE REVISIONS PV MODULE 36" x 30 GROUND ACCESS TYP. DESCRIPTION DATE PEV ORi�:Nn. -Jr_�7T RACKING RAIL 0 ATTACHMENT POINT ---RAFTERS -*—ROOF PITCH ANGLE 59SUNRUN METER ®VENT OPLUMBING VENT ®SKY LIGHT CONTRACTOR ®CHIMNEY ®COMPOSITE SHINGLES GOOD CONDITION �POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY ELEMENT ENERGY, LLC ACCESS ROOF 7470 SOUND AVE MATTITUCK. NY 1 195 ACCESS ROOF LICENSE # 43889-H LICENSE # 52G89-ME PROJECT NAME t LU Lz � U Q m NEW Y D Al z P�pgo A c,GsO C19LLJ Q C) e 11 W O I0 16 � L 2 O 1 Ln �4A 103443 O L v �OFESSIONP Q ' g SHEET NAME ( 51TE PLAN 351-911 'NOTE p THE ROOF ACCESS AND PATHWAY REQUIREMENTSv SHALL NOT BE APPLIED WHEN BACK OR ADJACENT ` 9O N ROOF ID 15 ACCESS ROOF 16NSACCORDANCE WITH NYS � p 3/ 1 6u I -U RE CONSTRUCTION NOTES Q 1 .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. CO p\ /_ 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I V 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: I OOOOG0000300024004 Zoho Sign Document ID: HOUWDBLJRCFKNDICCASW6TRPNYYFIXJVJCWIGUGVBTC CONSTRUCTION NOTES CONSTRUCTION SUMMARY NOTE TAX MAP: 1000OG9000300024004 'DESIGN a DRAFTING 6Y: 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE (I 9)QCELL Q.PETHE ROOF ACCESS AND PATHWAY REQUIREMENTS AK DUO BLK ML-G9+ 380 WATT PV MODULES ELEMENT ENERGY uc WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS. (DIMENSIONS: 72.4"X 40.6"X 1 .3") SHALL NOT BE APPLIED WHEN BACK OR ADJACENT REVIEW BY J.M.NABCEP CERTIFIE 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH (19) ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS ROOF IS ACCESS ROOF IN ACCORDANCE WITH NY5 os I 1 12-129 MINIMUM NEMA 3R RATING. (38)ATTACHMENT POINTS @ G4"O.C. MAX. RESIDENTIAL CODE R324.G EXCEPTIONS. p° 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE (146.I) LF IRONRIDGE XR 100 MOUNTING SYSTEM. ` gp v REVISIONS FIELD VERIFICATION. ROOF TYPE = ASPHALT SHINGLE(SINGLE LAYER) 0 DescRPrloN DATE a>v 3G" x 3G" GROUND ACCESS TYP. 5 CONTRACTOR ELEMENT ENERGY. LLC. 7470 SOUND AVE MATTITUCK. NY 1 195 LICENSE # 43889-H ACCESS ROOF LICENSE # 52289-ME ACCESS ROOF OF NEpV Y �P A O COGS w mLu ------ ----- �4 103443 W Z [� - - , �yOFESSIONP� z W LLJ � I I I I i J Ln LCA I - O I I - I ! I LEGEND -'- o EXISTING UTILITY METER 0 I I I 1 ®MAIN SERVICE PANEL 3 1I I I ( I I 11 NEW PV SUB-PANELS 311 DISCONNECT I I I I I I coM131NER �r1FET NAME 1 INVERTERS _ u GND ELECTRODE APV MODULE 1,001F DETAIL RACKING RAIL O ATTACHMENT POINT 3" 3" - --RAFTERS DRAWING SCAL` *—ROOF PITCH ANGLE ARRAY #2 ARRAY # I I i0�1 �suNRUN METER �/ I /'bII _ _A1 7 MODULES 1 2 MODULES 32°PITCH 32°PITCH ®VENT 203°AZIMUTH 203°AZIMUTH 0PLUMawG VENT I ®SKY LIGHT ``IVI •WI• SHEET NUMBER ®CHIMNEY COMPOSITE SHINGLES P V 3 _GOOD CONDITION POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSAR Zoho Sign Document ID: HOUWDBLJRCFKNDICCASW6TRPNYYFIXJVJCWIGUGVBTC LOAD CALCLILATION ARRAY#I ARRAY#2 ITEM DESCRIPTION ARRAY#1 4�#2 :BIY 4 DRAFTING BY: (RB) Rld e Beart/BOarG( `' NT ENERGY LLC MODULE WEIGHT(lbs) 43.0 43.0 R. Rafters REVIEM.NABCEP CERTIFIE (D) Deckln /o x D __ #OF MODULES 12 7 (P) Pitch 32' TOTAL MODULE WEIGHT(Lbs) 5 1 G.O 301.0 1(J) I Ceiling J015t 2"X 5" D. FIR p REVISIONS TOTAL LENGTH OF RAIL(Ft) 98.1 48 (h) 1lorizontal Span of(R) 147" MAX. DESCRIPTION DATE TEV Y RAIL WEIGHT PER FOOT(Lbs) of NEw s) O.GB O.GB '� ORIGINAL Js-2o� pqG� O TOTAL RAIL WEIGHT(Lbs) GG.7 32.G C/) ��� Gs� p #OF 5TKANDOFF5 24 14 WEIGHT PER 5TRANDOFF(Lbs) 2 2 0 ,i TOTAL 5TANDOFF WEIGHT(Lbs) 48 28 (D) 'r-rJ TOTAL ARRAY WEIGHT(Lbs) 630.7 3G I.G �� 1p3443 POINT LOAD(Lbs) 2G.3 25.8 A� Ss�p`_Q\' I CONTRACTOR I TOTAL ARRAY AREA(5q Ft) 249.6 145.6 I I I ARRAY DEAD LOAD(Lbs/Sq Ft) z.s 2.5 ( ) i ELEMENT ENERGY. LLC. 7470 SOUND AVE WIND DESIGN SUBJECT TODAINAGEFROM I GROUND SEISMIC WINTER ICE BARRIER FLOOD AIR MEAN MATTITUCK, NY 1 1952 SNOW Special Windborne DESIGN Frost DESIGN .. - -ENT FREEZING ANNUAL speed Topographic x � I LICENSE # 43889-h LOAD* k wind debris CATEGORY/ Weathering° line Termite` TEMP' REQUIREDh HAZARDS INDEX' TEMW I (mph) tffects region' depth° I LICENSE # 52689-ME 1 20 140 NO NO NO B SEVERE 3 FT HEAVY 15'F YES EMA 599 51'F ZONE X J DESIGN CRITERIA" Indoor Design Heating Winter Summer Altitude Elevation Latitude design temperature ) I PROJECT NAME heating cooling correction factor temperature cooling i temperature difference l (J) 108 FT 41'N 15'F 86'F 1.00 70'F 75'F 55'F Cooling Wind Wind Coincident Daily Winter Summer [L] temperature difference velocity velocity wet bulb range humidity humidity heating cooling LU z 11°F 15 MPH 1 7.5 MPH 72'F MEDIUM(M) 40% 32 GR @50%RH z For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL 1 W ]L] a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength �r 1 z Z required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined v 1 from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. LLJQ b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction J shall fill in the frost line depth column with the minimum depth of footing below finish grade. W O C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. MODULE MOUNTING CLAMP J = d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined _J on a site-specific basis in accordance with Section R301.2.1.4. SOIAR MODULE O 4. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York Lo 0 — 0 State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also 5TAINLE55 STEEL 3/ see Figure R301.2(1).] BOLT AND NUT E The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. , g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: i.The accompanying Flood Insurance Rate Map(FIRM), NRIDGE ALUMINUM RAIL ii.Flood Boundary and Floodway Map(FBFM),and ALUMINUM"L"BRACKET SHEET NAME iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. In. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM FLASHING effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." ��pKI U I�l l U p /� I\&1 I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32'F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (Base 32°F)." ASPHALT 511INGLE ROOF k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 5/1 G"x G"5TAINLE55 jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. 5TEEL LAG BOLT WITH DRAWING SCALE I. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with 2 1/2"MIN THREAD "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION 5EALED A5 NOTED m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the WITH GEOCEL 4500 table. (EQUIVALENT OR BETTER) n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1 a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. 0. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. SHEET NUMBER (`) See Figure R301.2(4)B. PV-4 TAX MAP: 1000069000300024004 MOUNTING DETAIL I Zoho Sign Document ID: HOUWDBLJRCFKNDICCASW6TRPNYYFIXJVJCWIGUGVBTC SOLAR ARRAY ON MAIN HOUSE 8.27 kW DESIGN a DRAFTING BY: (1 9)QCELL Q.PEAK DUO BLK-ML G9+ 380 PV MODULES ELEMENT ENERGY LLC (1)STRING OF(1 2)MICRO-INVERTERS 4(1)STRING OF(7)MICRO-INVERTERS REVIEW 5Y J.M.NABCEP CERTIFIf '(2)STRINGS TOTAL 051 1 12-129 TO UTILITY GRID REV1510N5 STRING # I DESCRIPTION DATE Uv --------------------- n : - BIDIRECTIONAL I � o UTILITY METER ------------------ -- ------ -_---- ------ -_-- -- --- ---- -- ----- --- PHASE.240 V j 1 N iC -FyTAPjD,,STOP STRING #2 17- I CONTRACT-:- t 1 ENPHASE BRANCH CIRCUIT CABLE TYPICAL i ELEMENT ENERGY, LLQ. 1 1 7470 SOUND AVE I AC D15CONNECT MATTITUCK, NY 1 1952 I ' I i s�D 32z3NR5 LICENSE # 43889-H ' 2401AC LOA 1 1 LICENSE # 52G89-ME - NEMA A l4= ". 1 1 1 1 1 ¢ PROJECT NAME MAIN 5ERVICE PANEL � r r I AC connSiNER BOX p� r . ��, N N an, 1 2 ' I I N « ('> I I I EX15TING GROUNDING U Q 103443 �___________J j ELECTRODE 5Y5TEM z J ARS LLJ SSIONP� I � - (S) z ---------------------------------------------------- LLj WIRE CONDUIT SCHEDULE QLU O CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX. CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% J - I.D. # ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE IN5ULATION 51ZE QUANTITY IN5ULATION (CU/AL) TYPE 51ZE TEMP DERATE DISTANCE ^ _ 310.15(5)(3) 310.15(5)(20(3c) O u 1 INVERTERS COMBINER PANEL AWG#10 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR I., 70QC O.G5 I 10 FT 1.8% - OR EMT COMBINER PANEL AC DISCONNECT G#10 1 3 I THWN-2 I THWN-2 CU PVC 45QC 0.87 25 FT 1.3% AC DISCONNECT MAIN PANEL ✓G#G 1 3 THWN-2 - I THWN-2 CU PVC 45QC 0.87 10 FT 0.1% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL. AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Ampaaty Calculation CONFIGURATION ALL CONDUCTORS SHALL BE COPPER. RATED FOR GOO V AND 909C WET ENVIRONMENT. [NEC G90.8(B)(I)]: (Ise)'(#of sten s)'(I.5G) = 18.15 A Modules 3-LINE DIA. ,;.)WIRING.CONDUIT.AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY per String TO. AND LOCATED AS CL05E AS P0551BLE TO THE NEAREST RIDGE. HIP. OR VALLEY. AWG# O. ampacity' Temp Derate = 20.8 A 20.8 A> 1 8.1 5 A. therefore DC wire size Is valid. Modules per Inverter 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters COMPLY WITH NEC 1 10.2G. #2 Inverter Output Wire Ampaaty Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 28.74 A Record low tem FURNISH ALL NECESSARY OUTLETS. SUPPORTS. FITTINGS AND ACE550RIE5 TO FULFILL AWG#10. ampaaty'(Temp Derate)'(Conduit Fill Derate) = 34.8 A Voc Temp Coefficient DRAWING SCALE APPLICABLE CODES AND STANDARDS. 34.8 A > 28.74 A. therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS. AND CONDUITS ARE NOT SPECIFIED. #3 Inverter Output Wire Ampaaty Calculation Operating Current N .T. . THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Amperage output' (1.25) = 28.74 A O eratin Volta e 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. AWG#G, am aat (Tem Derate)*(Conduit FIII Derate) = G5.25 A Max. 5 stem Volta e )C'.0 -em ##QC- (Voc))+(Voc 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE 65.25 A > 28.74 A. therefore AC wire size is valid. y p SUPPORT RAIL PER THE GROUNDING CLIP MANUFACTURER'S ItISTRUCTION. Short Circuit Current G90.b� 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG AC SYSTEM SPECIFICATIONS OR ILSCO G13L-4DBT LAY-IN LUG. Max AC Output Current �\ /- O.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positive/negative) O eratin AC Volta e 240 V v OR 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000OG9000300024004 Zoho Sign Document ID: HOUWDBLJRCFKNDICCASW6TRPNYYFIXJVJCWIGUGVBTC SERVICE METER O O DESIGN i DRA`TING BY: INSTALLATION NOTE ELEMENT ENERGY LLC I SOLAR PV SYSTEM ` j PHOTOVOLTAIC ; • mill REVIEW BY J.M.NAECEPCERTI" ( I ) ALL LABEL SHALL BE INSTALLED IN osl 1 .2-,2a I EQUIPPED WITH i SOLAR BREAKER ` • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® •' ' REQUIREMENTS. REVISIONS DESCRIPTION DATE REV LTAGE OPERATING PR R •R (2) ALL LOCATIONS ARE APPROXIMATE ANDMAX SYSTEM VVDC --» SOLAR AC LOAD CENTER - OUTSIDE jDONOT RELOCATETHIS SHORT CIRCUIT CURRENT A REQUIRE FIELD VERIFICATION. i (3) LABELS, WARNING(5) AND MARKING 0 TIMROOSHUMOWNSMTOTO 9 � F• SHALL BE IN ACCORDANCE WITH NEC THE•OPOSITM TO SHUTDOWN I 10.2 1 (B). # PV SYSTEM MO FEDUIE CAUTION SIM POWERMT•SSERVICE16ALM SUPPLIED (4) THE MATERIAL USED FOR MARKING _ _- _ _ AC DISCONNECT FROM TM FpypyOW SppRCES VfiT DMCOWE`TS`°`AWD SHVM MU5T BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - IN5IDE CONTRACTOR ' Z COMPLIANCE WITH NEC 1 10.2 1 (B)(3). (5) THE PV SYSTEM CIRCUIT CONDUCTORS ® O7 ® I I zLWARNING r 5HALL BE LABELED INSTALLED IN ELEMENT ENERGY. LLC. TMEUIPIENTFEDSYMULTMLE DUAL POWER SUPPLY 7470 SOUND AVE souRCESTooltweaNcaFal COMPLIANCE WITH NEC 690.3 1 . OIIERCUIITWM,EXCLUOUNG', SOURCES.UTILITY GRID MATTITUCK. NY 11952 � IIIINaPRYOVBICURRM AND PV SOLA LICENSE # 43889-11 � ELECTRIC SYSTEM /—� CONDUIT - INSIDE BUILDING 3O � LICENSE # 52689-ME � I WARNING -i THG SERVICE METE-_ PROJECT NAV` IS ALSO SERVED BY A ELECTRIC SHDCIC WIZARD 1 TOSYSTEM PHOTOVOLTAIC SYSTEM TERMINALS ON THE U E AND PANEL LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS CONDUIT - OUTSIDE BUILDING - IN THE OPEN POSITION " W LLJ z YARNING L ' w w OVAL POWER SUPPLY z SOURCES:UTILITY �PV SOLAR ELECTRIC SYSTEM L �iQz ' J MAIN SERVICE PANEL - OUTSIDE 5 O J0 O A CAUTION SOLAR CIRCUIT Z J LCA 1-- -- CAUTION o SOLAR ELECTRIC SYSTEM CONNECTED — O MAIN SERVICE PANEL - INSIDE MARNING A ,. .. • POWER SOURCE i OUTPUT CONNECTION ® O DO NOT RELOCATE THIS ! O� EIN y 51EET NAME OVERCURRENT DEVICE Q� O A 0 ���c�c�Gs��� LABELS �f .` z it AC DISCONNECT/BREAKER 2 IO3 9 4 �OA� X03443 P��? NH. I . \2j a ss,ON S. TAX MAP: I OOOOG0000300024004