HomeMy WebLinkAbout46998-Z .�SufFac�
CotGy Town of Southold 2/15/2022
P.O.Box 1179
N x 53095 Main Rd
�y�ja oo� Southold,New York 11971
CERTIFICATE OF OCCUPANCY
No: 42799 Date: 2/15/2022
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 2175 Pine Neck Rd., Southold
SCTM#: 473889 Sec/Block/Lot: 70.-5-48
Subdivision: - Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
10/5/2021 pursuant to which Building Permit No. 46998 dated 10/18/2021
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
roof mounted solar panels to existing single family dwelling as applied for.
The certificate is issued to Lindh,Alexander
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 46998 1/5/2022
PLUMBERS CERTIFICATION DATED X (
0 (7 o iz d Signature
-2M TOWN OF SOUTHOLD
ay BUILDING DEPARTMENT
2 TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 46998 Date: 10/18/2021
Permission is hereby granted to:
Lindh, Alexander
282 County Rd
Cresskill, NJ 07626
To: Install roof mount solar panels to existing single family dwelling as applied for.
At premises located at:
2175 Pine Neck Rd., Southold
SCTM #473889
Sec/Block/Lot# 70.-5-48
Pursuant to application dated 10/5/2021 and approved by the Building Inspector.
To expire on 4/19/2023.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CO-ADDITION TO DWELLING $50.00
Total: $200.00
Building Inspector
SOUr�,OI
� o
Town Hall Annex Telephone(631)765-1802
54375 Main Road
P.O.Box 1179 sean.devlin(-town.southold.ny.us
Southold,NY 11971-0959 Q�yCOU�,�,��\
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: Alexander Lindh
Address: 2175 Pine Neck Rd city:Southold st: NY zip: 11971
Building Permit#: 46998 & 47000 Section: 70 Block: 5 Lot: 48
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Element Energy LLC License No: 52689ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Solar X
Commerical Outdoor X 1st Floor Pool
New X Renovation 2nd Floor Hot Tub
Addition Survey Attic Garage
INVENTORY
Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel X A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks
Disconnect 77.1A Switches 4'LED Exit Fixtures Pump
Other Equipment: 19.38kW Roof Mounted PV Solar Energy System w/ (51) Qcell Qpeak DuoBlk G9+3E
Modules , (35) On House (16) On Garage, Combiner Panel w/220x5 Solar & 215x1 Monitor,
Notes: PV AC Disconnect 77.1A
Solar
Inspector Signature: Date: January 5, 2022
S.Devlin-Cert Electrical Compliance Form
�o��pF SOGTyO�
# # TOWN OF SOUTHOLD BUILDING DEPT.
co 765-1802
a _INSPECTION
[ ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND [ ]. SULATION/CAULKING
[ ] FRAMING /STRAPPING [ FINAL SbL4r,
[ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O
REMARKS:
t J ofko,
DATE I INSPECTOR
•FIELD:INSP XTION REPORT'. 'DATE ..
-CIO.
FOVNn�ATo�v tib :. o
D.
rA
RQUG FRAMINQ;'& . . H
; i
INSULAITION..PER N.Y. H
STATE.tNERGY CODE
. . r
� .
J FINAL' .
RL
i
70
t
i.. .I: ~ ►
Zoho Sign Document ID:HUOE6XE(3HOZNDIRZ8UA8S_STMIIA6U0JVSZZSIJTZT4
-S,dFFO(r-^oGy TOWN OF SOUTHOLD —BUILDING DEPARTMENT
y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959
Telephone (631) 765-1802 Fax (631) 765-9502 Vis://www.southoldtowm.gov
Date Received
APPLICATION FOR BUILDING PERMIT
f!� evil
(� For Office Use Only EC
44
ED
PERMIT NO. T Building Inspector: OCT 0 5 2021
BUILDING DEPT.
Applications and forms must be filled out in their entirety.Incomplete TOWN OF SOUTHOLD
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date:10/4/21
.OWNER(S)OF PROPERTY:
Name:Alexander Lindh SCTM#1000- 70 0 5 0(4
_000
Project Address:2175 Pine Neck, Southold, NY 11971
Phone#:6317797993 Email:permits@e2sys.com
Mailing Address:7470 Sound Ave MattituCk NY 11952
CONTACT PERSON:
Name:Danielle Rodger
Mailing Address:7470 Sound Ave MattituCk NY 11952
Phone#:6317797993 Email-:permits@e2sys.com
DESIGN PROFESSIONAL INFORMATION:
Name:
Mailing Address:
Phone#: Email:
CONTRACTOR INFORMATION:
Name:Element Energy LLC
Mailing Address:7470 Sound Ave Mattituck NY 11952
Phone#:6317797993 _ Email-:perm its@e2sys.com
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project:
D OtherSolar $82473.00
161
Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No
1
Zoho Sign Document ID:HUOE6XEUHOZNDIRZBUA88_STMIIA6UOJV8ZZSIJTZT4
PROPERTY INFORMATION
Existing use of property: Intended use of property:
Residential. . . —Residential
_-Residential
Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to
AC Residential this property? ❑Yes ®No IF YES, PROVIDE A COPY.
❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION Is HEREBY MADE to the Building Department.for the issuance of'a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal,or demolition,as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable-as a Gass A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name):Danielle Rodger ®Authorized Agent ❑Owner
Signature of Applicant: Date: 10/5/21
STATE OF NEW YORK)
SS:
COUNTY OF )
Danielle Rodger being duly sworn, deposes and says that(s)he is the applicant
(Name of individual signing contract)above named,
(S)he is the Agent
(Contractor,Agent, Corporate Officer, etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
5 day of October 2021 6_, 0. Lustt���
Notary Pu lic
DEBRA A SEPULVEDA
NWMWPU1IUQSTAU0FNRW=9
PROPERTY OWNER AUTHO IZATI0I%siwwoamoism2W
(Where the applicant is not th Q)N er QnaUfl�inSuo'
My on Ezpi�s'.
I, residing at
Alexander Lindh 2175 Pine Neck, Southold, NY 11971
do hereby authorize Element Energy to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
J - 10/5/21
Owner's Signature Date
Alexander Lindh
Print Owner's Name
2
O�,gufFO( �oG BUILDING DEPARTMENT- Electrical Inspector
TOWN OF SOUTHOLD
y z Town Hall Annex - 54375 Main Road - PO Box 1179
Southold, New York 11971-0959
Telephone (631) 765-1802 - FAX (631) 765-9502
1 "
roger (c southoldtownny.gov - sea nd(cD-southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date:
Company Name: ySLG
Electrician's Name: / / ICGt
License No.: C;-6�/-` C,7 Elec. email: d �e -�--r s, r r-�
Elec. Phone No: 6,3/ 777 7993 request an email copy of Certificate of Compliance
Elec. Address.: 7V70r�/
JOB SITE INFORMATION (All Information Required)
Name:
Address: 0241E-6211 11f21
Cross Street:
Phone No.: 31 ? 27 777
Bldg.Permit#: email:
Tax Map District: 1000 Section: _07000 Block: 9_5-OBJ Lot: O �6
BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly):
Square Footage:
Circle All That Apply:
Is job ready for inspection?: ❑ YES NO ❑ Rough In ❑ Final
Do you need a Temp Certificate?: F-1YES
II NO Issued On
Temp Information: (All information required)
Service Size 1-11 Ph❑3 Ph Size: A # Meters Old Meter#
❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead
# Underground Laterals 1 2 H Frame Pole Work done on Service? Y N
Additional Information: SQL cJ 3� C��� SCeill
11IN (FV�Ae .
PAYMENT DUE WITH APPLICATION
APPROVED AS NOTED OCCUPANCY O
DATE-
045- B.P.# 4k 06' S' USE IS UNLAVi°JFUL
g�
FES 4 Y: WITHOUT CER T IRC.
NOTIFY BUILDING DEPARTMENT AT � OCCUPANCY7R, '802 8 AM TO 4 PM FOR THE
F' _OWING INSPECTIONS:
1. FOUNDATION - TWO REQUIRED
PC
)R POURED CONCRETE
2. =. ;r I=RAM'NG & PLUMBING
3.
4. F N CONSTRUCTION MUST
BE OMPLETE FOR C.O. COMPLY WITH ALL CODES OF
.;
ALL � :;'•ISTRUC?ION SHALL MEET THE
REQNEW YCaRK STATE & TOWN CODES
REQUIREMENTS OF THE CODES OF NEW AS REQUIRED AND CONDITIONS OF
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS.
SOUTHOLD TOWN ZBA
SOUTHOLD TOWN PLANNING BOARD
SOUTHOLD TOWN TRUSTEES
6=McA.tNSa>I CnM pjEQUMED N.Y.S.DEC
RETAIN STORM WATER RUpvlJl
PURSUANT TO CHAPTER 236
OF THE TOWN CODE.
Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0
` Town of Southold September 27th, 2021
Building Department
Town Hall Annex
54375 Main Road
P.O. Box 1179
Southold, New York 11971-0959
Subject: Roof Mounted Solar Panels at the Lindh Residence,2175 Pine Neck Rd. Southold, NY
11971
To Whom It May Concern;
hereby state that it is my professional opinion that the subject plans comply with the 2020
Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and
NEPA-70. These code requirements include the fact that the roof framing is adequate to support
the additional loads from solar,panels as well as roof ridge and peak access to first responders.
I have evaluated the structural framing of the existing roof with the additional loading to account
for the proposed solar panel application. Deflection and stresses of the structural components
remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second
gust, Exposure B with a ground snow load of 20 pound's per square foot. Mounting locations
and methods are as indicated in the submitted plans.
From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is
my professional opinion that the existing building and roof framing is structurally adequate to
support the reactions of the solar panels in addition to the existing code required for live and
dead loads.Also the wind analysis concluded that the mounting system as shown on the plans
is adequate to resist the calculated uplift pressure.The dead load of the heaviest solar panel
assembly in this evaluation is approximately 2.4 pounds per square foot,.
Please contact me if you have any questions or comments about the above.
Sincerely,
Gennaro Anthony Ciustra. P.E. ,` Oo AEc YO
Creat Eastern Services, Inc. =fit Gs�'AiT
PO Box 240
24 Harvey Rd ''
n w
Riverhead, NY 11901 2 z
Office; 631.543.9555 �O10 103443�1P Ali
Mobile 631.235.0189 FESSIO
Email: jerrygiustra@gmail.com
Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0
5COPE OF WORK DESIGN i DRAFTING BY:
Pd ELEMENT ENERGY LLC
TO INSTALL A 19.4 N SOLAR PHOTOVOLTAIC (PV)SYSTEM AT LINDH RESIDENCE, d Greenport REVI_RN 5Y J.M-NA5CEP CERTIFIE
LOCATED AT 2 175 PINE NECK RD,50UTHOLD, NY 1 197 1. West 051 1 12-129
THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID r1Rd
THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. E
10N5
,N
pF NEW DATE REV
'�
5Y5TEM RATING �P��VLO A G, 0;,per
25
19.41 kW DC STC <[/�
n lW l / Fc
EQUIPMENT SUMMARY ti� - � _ •
�O 703443
51 QCELL Q.PEAK DUO BLK ML-G9+ 380 WATT PV MODULES '� �. / �'�
51 ENPHA5E IQ7PLU5-72-2-U5 MICRO INVERTERS �OFESS1ONP CONTRACTOR
I IRONRIDGE XR100 MOUNTING SYSTEM
5MEET INDEX •40 ELEMENT ENERGY. LLC
Pv-1 COVER of �' F 7470 SOUND AVE
PV-2 517E PLAN 0'
Peconic MATTITUCK. NY 1195
PV-3--4 ROOF PV LAYOUT
PV-5 STRUCTURAL/DETAILS 8 SECTIONS I LICENSE # 43889-H
PV-G 3-LINE ELECTRICAL DIAGRAM LICENSE # 52G89-ME
PV-7 LABELS ® ~
W 270'090'90° E e �R°
GOVERNING CODES 4„ 6"'Rv
240° Q 120°
2017 NATIONAL ELECTRICAL CODE. 210° 150° 11 -� :i Bedell CellarsQ ` PROJECT NAV
2020 RESIDENTIAL CODE OF NEW YORK STATE. 180°
A5CE 7-1 6 AND NEPA-70.
UNDERWRITERS LABORATORIES(UL)STANDARDS S D /� Q
05HA 29 CFR 1910.269
OCT 0 5 2021 / -- - -
GENERAL NOTES PROJECT LOCATION 'L' O
BUILDING DEPT U a
1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT TOWN OF SOUTHOLD W
THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE C U }-
HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK z Z
AGREE THE SAME.
2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED �' � L1J C)
APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. •JFt"iv�j `' •� `� z O
INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, d �� ` •* _ (L =
AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED.
3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES tvc �: •
OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO
ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK.
JURISDICTION. 1 1 . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR t
4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE
WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS
THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND
ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT '
CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, t
RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 5rtffT NAME
5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT _
FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 CONSTRUCTION.
SPECIFICATIONS. - = `= COVER
12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE '1,
G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE
UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING (� t
NYS CODES REGULATIONS
CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING + c
1.
7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND
COMMENCING WITH WORK. � f
CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S
CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS ••
WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON a A 1 .I
8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND
SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BIBJASIS OR SOONER IF CONDITIONS WARRANT. ;
PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED ` ti
THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE Y '�
LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE
EXTENSIONS TO THIS PROJECT
9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF
EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV—
RESULT OF HIS WORK. AERIAL VIEW
TAX MAP: 1000070000500048000
Zoho Sign Document ID: NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXY000Q60W0
LEGEND
DESIGN 6 DRAFTING BY:
�DaSTING UTILITY METER
MAIN SERVICE PANEL ELEMENT LL
NEW PV SUB—PANELS N REVIEW B 05.1 NABC29 C�RTIFIE
A/C DISCONNECT
COMBINER O°
INVERTERS
REVISIONS
GND ELECTRODE
® DESCRI PfION DATE REV
PV MODULE
w270 a ORI&NAL je-27 202
RACKING RAIL 24 ° ®r7r__90.E
O ATTACHMENT PONT 120°
---RAFTERS 210o
-*—ROOF PITCH ANGLE 180o 150o
BSUNRUN METER S
®VENT
OPLUMBING VENT
®SKY LIGHT
CONTRACTCI,
®CHIMNEY
®COMPOSITE SHINGLES
GOOD CONDITION
❑POTENTIAL SHADING ISSUES
TRIM/REMOVE AS NECESSARY -EMENT ENERGY. LLC
7470 SOUND AVE
MATTITUCK, NY 1195:
'3" ACHED GARAGE LICENSE # 43889-H
LICENSE # 52489-ME
PROJECT NAME
Q
w O
U
z � _
C) w
a o — W z z
OF
NEw z y �Q o
PRO A C'ijG O,A ��' _ O
* a zlnD
103443 4
A��FESSIONP�
SHEET NAM`_
51TE PLAN
DRAWING SCALE
CONSTRUCTION NOTES
I .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBeR
MANUFACTURER'S INSTALLATION INSTRUCTIONS. PV-2
� /_
2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I V
3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000070000500048000
Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0
CONSTRUCTION SUMMARY — MAIN HOUSE TAX MAP: 1000070000500048000 DE51GN e DRAFTING BY:
(35) QCELL Q.PEAK DUO BLK ML-G9+ 380 WATT PV MODULES ELEM`NT ENERGY LLC
(DIMENSIONS: 72.4"X 40.6"X I .6") REVIEW BY J.M.NABCEP CERTIFIEC
(35) ENPHA5E IQ7PLU5-72-2-U5 MICRO INVERTERS 051 1 2-129
(56)ATTACHMENT POINTS @ 64"O.C. MAX.
(239.8) LF IRONRIDGE XR100 MOUNTING SYSTEM. REVISIONS
ROOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) 36" FIFE 5ETBACrJACCE55 PATH I I 6�Flt SE76�CCRTAC�E55FA
1 DESCRIPTION DATE <E�-
CON5TRUCTION NOTES )Rl,1,AL
1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTUREIR'5 INSTALLATION INSTRUCTIONS.
2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH — - i - ---
MINIMUM NEMA 3K RATING. 1
3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE — -
FIELD VERIFICATION. I LJ
-'
FE
- -
- coNrrzAcroP
_._. _ - _• _ r-. p
r - MENT ENERGY. LLC.
---- 7470 SOUND AVE
--I - -r-r-r-r- -
- - - I 1
35 MATTITUCK. NY 1 1952
LICENSE # 43889-H
1 1 1 LICENSE # 52689-ME
E_�_}_. . �,- ARRAY #2
ARRAY # I - 1 t � _ i +: i 17 MODULES
! _i 19°PITCH PROJECT NAM
16 MODULES _. _ –. _ 1
r L : 72°AZ
1 9°PITCH - LITH
252°AZIMUTH
o _
Q
�I
1 I LLl 01�
f �l
� U >-
pF NEIN – VV270�a 1L1 z
�P�pgO A 6' 0�� 240- �90-E LLJ LLl
-- -
- 1 1 — 210 o
120 D z
180o1s0� p_ _
- - -
O
I_
V
1 1 ,
O 103443 -- L ,
A�OFESSIONP� ,T T L. I j ! — LEGEND N21-5
EXISTING UTILITY METER
36"FIRE�SETBACK/ACCESS PATH MAIN SERVICE PANEL
36 FIRE S�TBA� JA ES�PgTH
AD NEW PSUB-PANELS
� A/C DISCONNECT
COMBINER SHEET NAME
INVERTERS
GND ELECTRODE
PV MODULE ROOF DETAIL
3G" x 36" GROUND ACCESS TYP. _RACKING RAIL
31-211- -- ATTACHMENT POINT
O-RAFTERS
DRAWING SCALE
f-ROOF PITCH ANGLE
tSUNRUN METER 3/ 1 G"
"SYSTEM SPECIFICATIONS NOTES' ®"ENT
TOTAL SYSTEM SIZE: 19.4 kW 0PLUMBING VENT
MODULES: (5 1) QCELL Q.PEAIC DUO 13LK-G9+ 380 PV MODULES ®SKY LIGHT
SHEET NUMBER.
INVERTERS: (5 1) ENPHASE IQ7PLU5-72-2-US MICRO-INVERTERS ®CHIMNEY
(35) MODULES INSTALLED ON THE MAIN HOUSE ®COMPOSITE SHINGLES PV_3
GOOD CONDITION
(I G) MODULES INSTALLED ON THE DETACHED GARAGE - POTENTIAL SHADING ISSUES
TRIM/REMOVE AS NECESSARY
Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0
CONSTRUCTION SUMMARY - DETACHED GARAGE TAX MAP: 1000070000500048000 DESIGN 4:DRAFTING BY
(I G) QCELL Q.PEAK DUO BILK ML-G9+ 380 WATT PV MODULES ELEMENT ENERGY LLC
(DIMENSIONS: 72.4"X 40.0 X I .G") N REVIEW BY J.M.NABCEP CERTIFI
(I G) ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS os I z- z?
0'
(24)ATTACHMENT POINTS @ G4"O.C. MAX.
(I 09.G) LF IRONRIDGE XR 100 MOUNTING SYSTEM. I FEV1510N5
ROOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) DEscRIFMON DATE REV
CONSTRUCTION NOTES -- - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - VV270°a 90° ""A- -)a-27
I .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 240°
E
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 210 D 120°150
2.) ALL OUTDOOR EQUIPMENT SHALL BE PAINTIGHT WITH °
MINIMUM NEMA 3R RATING. 180-
3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE - —
FIELD VERIFICATION.
— - — — — — — — — — — — — — — — — — —
I -
-- - - - --
ELEMENT ENERGY. LLC.
7470 SOUND AVE
- MATTITUCK. NY 1 195
- - J LICENSE # 43889-11
LICENSE # 52G(59-ME
PROJECT NAV-
ARRAY #3
6 MODULES
230 PITCH Lu O
260° AZIMUTH —
- - c) U
LLL
�- Cl/ W
Of Neiv
= z
-1 1-1 ;
A O
CO
LEGEND CV
EXISTING UTILITY METER
103443 �� ~ - MAIN SERVICE PANEL
A�lOw`P NEW PV SUB-PANELS
ss,O
A/C DISCONNECT
-- .-- _ .- -- .- -._. _ _- -,__ - - _ COMBINER SHEET NAME
, INVERTERS
'� GND ELECTRODE
PV MODULE ROOF DETAIL.
RACKING RAIL
I _ 0
ATTACHMENT POINT
1:5q ---RAFTERS
DRAWING 5Cn.
-*—ROOF PITCH ANGLE
59 SUNRUN METER 114''/it''
`SYSTEM SPECIFICATIONS t NOTES' I IL ®VENT T
TOTAL SYSTEM SIZE: 10.4 kW 21-2 4 0PLUMBING VENT
MODULES: (5 1) QCELL Q.PEAK DUO BLK-G9+ 380 PV MODULES ®SKY LIGHT
5h1EE?NUMBER
INVERTERS: (5 1) ENPHASE IQ7PLUS-72-2-U5 MICRO-INVERTERS ®CHIMNEY
(35) MODULES INSTALLED ON THE MAIN HOUSECOMPOSITE SHINGLES
PV-4
(I G) MODULES INSTALLED ON THE DETACHED GARAGE GOOD CONDITIONSHAD
CPOTENTIALLSHADING ISSUES
TRIM/REMOVE AS NECESSARY
Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0
LOAD CALCULATION ARRAY#I ARRAY#2 ARRAY#3 ITEM DESCRIPTION ARRAY#1 #2 ARRAY#
(RB) Rid ELEMEe Bea"E,oarci %" u DE-5iff s�f-w�5�.
R" � ��� �" X NT ENERGY LLC
MODULE WEIGHT(Lbs) 43.0 43.0 43.0 R Rafter5 REVIEW BY J.M.NA5CEP CERTIF!
(D) Deckinci i-LY�. 05 i i i 2-i 2a
#OF MODULE5 18 17 16 OF NEW (P) Pitch 23°
TOTAL MODULE WEIGHT(Lbs) 774.0 731.0 688.0 �` y M Cedincl J0I5t J. F 2° �D 24" C REVISIONS
A �, O (C) Collar D. FIZ a e x e` D. ')E5cRIPr10N DATE Rf
TOTAL LENGTH OF RAIL(Ft) 123.3 1 1 6.5 109.6 �Q - - -
� �w SGS (f1) horizontal Span of(R) -v - " ",^AY
RAIL WEIGHT PER FOOT(Lbs) 0.68 0.68 0.68 [(/� NAL Ce-27-2021
TOTAL RAIL WEIGHT(Lbs) 83.8 79.2 74.5 _`� ILU
#OF 5TRANDOFF5 28 28 24 m Z
WEIGHT PER STRANDOFF(Lbs) 2 2 2 �Q 103443
TOTAL STANDOFF WEIGHT(Lbs) 56 56 48 ��SS1O_`PV
TOTAL ARRAY WEIGHT(Lbs) 913.8 866.2 810.5
POINT LOAD(Lbs) 32.6 30.9 33.8 CONTRACTOR
TOTAL ARRAY AREA(5q Ft) 374.4 353.6 332.8
ARRAY DEAD LOAD(Lbs/5q Ft) 2.4 2.4 2.4 ELEMENT ENERGY. LLC
WIND DESIGN SUBJECT TO DAMAGE FROM 7470 SOUND AVE
GROUND SEISMIC FLOOD WINTER ICE BARRIER AIR MEAN (P) MATTITUCK. NY 1195c.
SNOW Special Windborne DESIGN Frost DESIGN UNDERLAYMENT FREEZING ANNUAL (C)
Speed
-Ph) effectsk Topographic wind debris r line Termite` TEMP' REQUIRED h HAZARDsg LICENSE # 43889-h
LOAD' (mph) I CATEGORY Weatheringa c INDEX'' 7ENPI LICENSE # 52689-ME
region 10'u- depth
20 140 NO NO NO B SEVERE 3 FT MOD TO HEAVY 15°F YES F NE X 599 51`F
MANUAL)DESIGN CRITERIAn
Winter SummerSummerIndoor Altitude Design Heating
Elevation Latitude heating cooling correction factor design temperature cooling temperature PROJECT NAM-_
temperature difference
108 FT 41°N 15'F 86°F 1.00 70'F 75°F 55°F
Wind Wind (J)
Cooling Coincident Daily Winter Summer
temperature difference velocity velocity wet bulb range humidity humidity
heating cooling ILL_] O
11°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%RH
For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n [J_J -
a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength LU z
required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined in z
from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. LL.J Q
b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction a/ LL_[ J
shall fill in the frost line depth column with the minimum depth of footing below finish grade. z O
C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. MODULE MOUNTING CLAMP = _
d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined C
on a site-specific basis in accordance with Section R301.2.1.4.
e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York 50LAK MODULE _z D
State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also 5TAINLE55 STEEL 3/8" J O
see Figure R301.2(1).] BOLT AND NUT
f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. N
g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New
York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the
Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with:
i.The accompanying Flood Insurance Rate Map(FIRM), NRIDGE ALUMINUM RAIL
ii.Flood Boundary and Floodway Map(FBFM),and ALUMINUM"L"BRACKET
iii.Related supporting data along with any revisions thereto. SHE`cT NAME
The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section.
h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM PLA5HING
effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO."
IT RU CT U RA
I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent)
value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)."
j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method
(Base 32°F)." ASPHALT 5HINGLE ROOF
k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 5/1 G"x G"5TAINLE55
jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. 5TEEL LAG BOLT WITH DRAWING SCALE
1. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with 2 1/2"MIN THREAD
"YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION 5EALPD
mA5 N OT t
. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the WITH GEOCEL 4500
table. (EQUIVALENT OR BETTER)
n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1 b from ACCA Manual J or established criteria determined by the
jurisdiction.
o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at
elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. 5HEET NUMBER
(') See Figure R301.2(4)B.
TAX MAP: 1000070000500048000 MOUNTING DETAIL
Zoho Sign Document ID: NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0
`SYSTEM SPECIFICATIONS $- NOTES` DESIGN a DRAFTING 5Y:
TOTAL SYSTEM 51ZE: 19.4 1 kW ELEMENT ENERGY LI-C
MODULES: (5 1) QCELL Q.PEAK DUO 6LK-G9+ 380 PV MODULES REVI_w 5Y J.M.NAECEP CERTIFIED
05 1 1 1 2-129
5TRINGS #l -2INVERTERS: (5 1) ENPHA5E IQ7PLU5-72-2-U5 MICRO-INVERTERS
r-_ ____________ _ -- -- (35) MODULES INSTALLED ON MAIN HOUSE REVISIONS
- - - - - - - - - -
F'] - - (I Q MODULES INSTALLED ON THE DETACHED GARAGE DESCwPTION DATE 4,
-.._..;A .09 2'2J2
I
I
I
STRING #3
IT---------------
I ----------
I
I --------------
TO UTILITY GRID
I I
I I
;7) e:NCS J '9)MC-0 N'.`eT`F.`; BI-DIRECTIONAL
CONTRACTOk
0 UTILITY METER
I I I-PHASE.240 V
STKING #4-5 El E3 N ELEMENT ENERGY. LLC.
' i r- -------- - - - - - - - - - - - - - - 7470 50UND AVE
I
----------
---- ----
MATTITUCr- NY 1 1 952
I `- ---- ---- ---- ---- ---- ��OF NEW�,�,Y
I I � LICENSE # 43889-h
I ENPHA5E BRANCH
CIRCUIT CABLE TYPICAL ' O q G� 0 LI N # 5
P O
CO g GSA
I I I 'TOTAL(2)CONDUITS
NONDUITS N
(1)ROR 5TRING#4-5 / 0
I
�4 703443
r - -- ARoFEssIll Q
I
I MAIN SERVICE PANEL ]_LJ O
I AC DISCONNECT
U 6
' .o oz_s,1eo
PV AC LOAD CENTER _ N /
G
W �L
N 1 I
M5TING GROUNDING Lu
j ELECTRODE 5Y5TEM Z
[L
I I =
� L1J
■ I - z O
I
WIRE CONDUIT SCHEDULE Z LF) ~
- CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP TIMA`::
ORIGIN DESTINATION 512E PER POLE QUANTITY DEBATE INSULATION SZ� QUANTITY INSULATION 'C�/A.; TYPE 51ZE TEMP DERAT` -STAN (�
31 O.13(51(3) 310.15(BN2a1"=.
INVERTERS COMBINER PANEL AWG#10 1 G 0.8 U5E-2/PV Wire Awo#8 1 BARE .-4-`AIR I" 7000 0.65 2.4% `V
`_MT
:7MBINER PANEL AC DISCONNECT AWG#4 3 THWN-2 - TtiWN-2 "✓C I" r 0.87 %
-)ISCONNPCT MAIN PANEL AWC#4 1 3 T.1WN-2 I TMWN-2 I/C = 0.87 C.I%
ELECTRICAL NOTES
-5r_c NAMF
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS
1.)ALL EQLJ1PMEt1T TO BE LISTED BY UL OR OTHER NRTL. AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acct Calculation CONFIGURATION
2.)ALL CONDUCTORS SHALL BE COPPER. RATED FOP GOO V AND 90QC WET ENVIRONMENT. p y 3_LI N F n( Q
3.)WIRING. CONDUIT.AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY [NEC (Isc) '(#of strmgs)'(I.56) = 19.GG A Modules per 5trtng 1 3.9 OR 8
TO. AND LOCATED AS CL05E AS P0551BLE TO THE NEAREST RIDGE. HIP.. OR VALLEY. AWG#I O. ampaaty'Temp berate = 26.88 A
26.88 A > 19.GG A. therefore DC were size Is valid. Modules per Inverter I
4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 51
COMPLY WITH NEC I 10.2G. #2 Inverter Output Wire Ampaaty Calculation
5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 77.14 A Record low tem -1 OQC
FURNISH ALL NECE55APY OUTLETS. SUPPORTS. FITTINGS AND ACE550RIE5 TO FULFILL AWG#4. ampacity'(Temp De rate)*(Cond uit Fill Derate) = 82.25 A Voc Temp Coefficient -0.24%/`'C DRAWING SCA,t
APPLICABLE CODES AND STANDARDS. 82.25 A > 77.14 A.therefore AC wire size Is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS
G.)WHERE SIZES OF JUNCTION BOXES. RACEWAYS. AND CONDUITS ARE NOT SPECIFIED. #3 Inverter Output Wire Ampaaty Calculation Operatinq Current I C.0 A =(#of strm s)'(Im ) N .T. .
THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Am era a output' (I.25) = 77. 4 A
7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. p g p O eratm Volta e 37.9 V =(#modules In series)'(Vm )
8.)MODULE GROUNDING S SH LL BE INSTALLED BETWEEN MODULE FRAME AND MODULE AWG#4. ampaaty'(Temp Derate)'(Condwt FIII Derate) = 82.25 A Max. System Voltage 49.3 V = (#modules In series)'[(((-#.##%V/QC'.O 1)'(Lo Temp##QC-25))'(Voc))+(Voc)]
82.65 A> 77.14 A. therefore AC wire size Is valid.
SUPPORT RAIL. PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 1 3.1 A =(#of sten s)'(Isc)'(I.25)per Art. G90.8(A)(1)
9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEED LUG AC SYSTEM SPECIFICATIONS SHEET NUMBEP
OR ILSCO G5L-4D8T LAY-IN LUG. Max AC Output
Current 77.14 A FV
/-
O.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) O eratm AC Volta e 240 V v �j
OR
10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000070000500048000
Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60WO
SERVICE METER OI O I� DE51GN$DRAFTING BY:
INSTALLATION NOTE ELEMENT ENERGY LLC
SOLAR PV SYSTEM I PHOTOVOLTAIC f • • • REVIEW 6Y J.M.NABCEP CERTIFIE
3 SOLAR ' ( I ) ALL LABEL SHALL BE INSTALLED IN D51 � .z-IzQ
EQUIPPED WITH • ACCORDANCE WITH THE 2017 NEC
RAPID SHUTDOWN ® •' " •URRENT ' REQUIREMENTS. rzevisloNs
OP
RDE5CR7 PilON DATE REV
(2) ALL LOCATIONS ARE APPROXIMATE AND
MAX SYSTEM VOLTAGE VDC
SOLAR AC LOAD CENTER - OUTSIDE �DONOT RELOCATE PIS: O• REQUIRE FIELD VERIFICATION.
OVERaURRMoEnCE ' (3) LABELS, WARNING(5) AND MARKING
0
TURN RAPID SHuroowNSWITCH To g Q SHALL BE IN ACCORDANCE WITH NEC
THE'OFF POSITION To SHUT Dowty 0 I 1 0.2 1 (b). -- - .
I PV SYSTEM AND REDUCE CAUTION
WU HAZARD 11 THE ARRAY AC DISCONNECT °OWERTOT SERVCE18AMSF°"® (4) THE MATERIAL USED FOR MARKING -
FROM TW
OWCONE""O°"1ED AS tNO"" MUST BE WEATHER RESISTANT, IN
SOLAR AC LOAD CENTER - IN51DE 2 U71 coNTRACTOR
(y w„�R COMPLIANCE WITH NEC 1 10.2 1 (3)(3).
P:NU (5) THE PV SYSTEM CIRCUIT CONDUCTORS
® O7 ® I I a ARNIN WARNING SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLC.
THIS EQUIPMENT FED BY MuLnPLE
SOURCES TOTALRATMIGOFALL DUAL POWER SUPPLY *% COMPLIANCE WITH NEC 690.3 I . 7470 souND AVE
OVERCURRENT DEVICES ExCLUDMIc SouRCES:UTILITY GRID — __ _ MATTITUCK, NY 1 1 95
MAIN SUPPLY OVERCURRENT AND PV SOLAR
LICENSE # 43(589-H
DESH�ALLN ELECTRIC SYSTEM
CONDUIT - INSIDE BUILDING LICENSE # 52689-ME
Q3 _ k,VARNING
IS ALSO SERVED BY
THIS SERVICE METER
ARN I N I A , PROJECT NAME
ELECTRIC SHOCK HAZARD I PHOTOVCILTAIC SYSTEM PHOTOVOLTAIC SYSTEM
TERMINALS ON THE UNE AND COMBINER PANEL
LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS Q
CONDUIT - OUTSIDE BUILDING I"TMEO�NPosITION
Q
0 ® Q)
!\WARNING
LLJ
DUAL POWER SUPPLY W
ISOURCES:UTILITY GRID AND i � W Z
PV SOLAR ELECTRICSYSTEM
MAIN SERVICE PANEL - OUTSIDE CL/ lLJ
OA CAUTION SOLAR CIRCUIT Z J
5 � tL =
A CAUTION z 0
SOLAR ELECTRIC SYSTEM CONNECTED _l l
O • • • N
MAIN SERVICE PANEL - INSIDE MARNING .. ,. ., •, �• A\ NEW yO
POWER SOURCE ,`Q' R0 A G'�
OUTPUT CONNECTION CO
® O DO NOT RELOCATE THIS S� SHEET NAV'
OVERCURRENT DEVICE
LU LABELS
3 !�
AC DISCONNECT/B1034
SSREAKER �OARO ;ONP�' DRAWING SCALE
FE
(1)(D N .T.S.
SHEET NUME,`,
PV-7
TAX MAP: 1000070000500048000