Loading...
HomeMy WebLinkAbout46998-Z .�SufFac� CotGy Town of Southold 2/15/2022 P.O.Box 1179 N x 53095 Main Rd �y�ja oo� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42799 Date: 2/15/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2175 Pine Neck Rd., Southold SCTM#: 473889 Sec/Block/Lot: 70.-5-48 Subdivision: - Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/5/2021 pursuant to which Building Permit No. 46998 dated 10/18/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels to existing single family dwelling as applied for. The certificate is issued to Lindh,Alexander of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46998 1/5/2022 PLUMBERS CERTIFICATION DATED X ( 0 (7 o iz d Signature -2M TOWN OF SOUTHOLD ay BUILDING DEPARTMENT 2 TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46998 Date: 10/18/2021 Permission is hereby granted to: Lindh, Alexander 282 County Rd Cresskill, NJ 07626 To: Install roof mount solar panels to existing single family dwelling as applied for. At premises located at: 2175 Pine Neck Rd., Southold SCTM #473889 Sec/Block/Lot# 70.-5-48 Pursuant to application dated 10/5/2021 and approved by the Building Inspector. To expire on 4/19/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ADDITION TO DWELLING $50.00 Total: $200.00 Building Inspector SOUr�,OI � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.devlin(-town.southold.ny.us Southold,NY 11971-0959 Q�yCOU�,�,��\ BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Alexander Lindh Address: 2175 Pine Neck Rd city:Southold st: NY zip: 11971 Building Permit#: 46998 & 47000 Section: 70 Block: 5 Lot: 48 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Element Energy LLC License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel X A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 77.1A Switches 4'LED Exit Fixtures Pump Other Equipment: 19.38kW Roof Mounted PV Solar Energy System w/ (51) Qcell Qpeak DuoBlk G9+3E Modules , (35) On House (16) On Garage, Combiner Panel w/220x5 Solar & 215x1 Monitor, Notes: PV AC Disconnect 77.1A Solar Inspector Signature: Date: January 5, 2022 S.Devlin-Cert Electrical Compliance Form �o��pF SOGTyO� # # TOWN OF SOUTHOLD BUILDING DEPT. co 765-1802 a _INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]. SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL SbL4r, [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: t J ofko, DATE I INSPECTOR •FIELD:INSP XTION REPORT'. 'DATE .. -CIO. FOVNn�ATo�v tib :. o D. rA RQUG FRAMINQ;'& . . H ; i INSULAITION..PER N.Y. H STATE.tNERGY CODE . . r � . J FINAL' . RL i 70 t i.. .I: ~ ► Zoho Sign Document ID:HUOE6XE(3HOZNDIRZ8UA8S_STMIIA6U0JVSZZSIJTZT4 -S,dFFO(r-^oGy TOWN OF SOUTHOLD —BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 Vis://www.southoldtowm.gov Date Received APPLICATION FOR BUILDING PERMIT f!� evil (� For Office Use Only EC 44 ED PERMIT NO. T Building Inspector: OCT 0 5 2021 BUILDING DEPT. Applications and forms must be filled out in their entirety.Incomplete TOWN OF SOUTHOLD applications will not be accepted. Where the Applicant is not the owner,an Owner's Authorization form(Page 2)shall be completed. Date:10/4/21 .OWNER(S)OF PROPERTY: Name:Alexander Lindh SCTM#1000- 70 0 5 0(4 _000 Project Address:2175 Pine Neck, Southold, NY 11971 Phone#:6317797993 Email:permits@e2sys.com Mailing Address:7470 Sound Ave MattituCk NY 11952 CONTACT PERSON: Name:Danielle Rodger Mailing Address:7470 Sound Ave MattituCk NY 11952 Phone#:6317797993 Email-:permits@e2sys.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Element Energy LLC Mailing Address:7470 Sound Ave Mattituck NY 11952 Phone#:6317797993 _ Email-:perm its@e2sys.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: D OtherSolar $82473.00 161 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 Zoho Sign Document ID:HUOE6XEUHOZNDIRZBUA88_STMIIA6UOJV8ZZSIJTZT4 PROPERTY INFORMATION Existing use of property: Intended use of property: Residential. . . —Residential _-Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to AC Residential this property? ❑Yes ®No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION Is HEREBY MADE to the Building Department.for the issuance of'a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal,or demolition,as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable-as a Gass A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Danielle Rodger ®Authorized Agent ❑Owner Signature of Applicant: Date: 10/5/21 STATE OF NEW YORK) SS: COUNTY OF ) Danielle Rodger being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 5 day of October 2021 6_, 0. Lustt��� Notary Pu lic DEBRA A SEPULVEDA NWMWPU1IUQSTAU0FNRW=9 PROPERTY OWNER AUTHO IZATI0I%siwwoamoism2W (Where the applicant is not th Q)N er QnaUfl�inSuo' My on Ezpi�s'. I, residing at Alexander Lindh 2175 Pine Neck, Southold, NY 11971 do hereby authorize Element Energy to apply on my behalf to the Town of Southold Building Department for approval as described herein. J - 10/5/21 Owner's Signature Date Alexander Lindh Print Owner's Name 2 O�,gufFO( �oG BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD y z Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 1 " roger (c southoldtownny.gov - sea nd(cD-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: ySLG Electrician's Name: / / ICGt License No.: C;-6�/-` C,7 Elec. email: d �e -�--r s, r r-� Elec. Phone No: 6,3/ 777 7993 request an email copy of Certificate of Compliance Elec. Address.: 7V70r�/ JOB SITE INFORMATION (All Information Required) Name: Address: 0241E-6211 11f21 Cross Street: Phone No.: 31 ? 27 777 Bldg.Permit#: email: Tax Map District: 1000 Section: _07000 Block: 9_5-OBJ Lot: O �6 BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: ❑ YES NO ❑ Rough In ❑ Final Do you need a Temp Certificate?: F-1YES II NO Issued On Temp Information: (All information required) Service Size 1-11 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service❑Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: SQL cJ 3� C��� SCeill 11IN (FV�Ae . PAYMENT DUE WITH APPLICATION 17-—0 bl I \\ NYSI F New York State Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) r AAA^A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449 444-5 706281 07/13/2021 TO 07/13/2022 7/15/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:NWWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:438572026 U-26.3 YORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1 c.Federal Employer Identification Number of Insured Work Location of Insured(Only required if coverage is specifically limited to or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 823336604 2.Name and Address of Entity Requesting Proof of Coverage 3a. Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Main Rd 3b. Policy Number of Entity Listed in Box"I a" Southold, NY 11971 DBL567527 3c.Policy effective period 01/01/2021 to 12/31/2022 4. Policy provides the following benefits: M A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/15/2021 By w4 ht (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4C or 56 of Part i has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (10.17) IIII DB-120. 1 (10-17) A ® DATE(MMY ) CERTIFICATE OF LIABILITY INSURANCE 7/15/7/15/20021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS.FEDE INSURANCE AGENCY PHONE 631- -1 76U FAX -3k3b-1 166 A/C No Ext): A1C No): 23 GREEN STREET,SUITE 102 E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSURERS AFFORDING COVERAGE NAIC# INSURER A:AILA INSURED INSURER B:STATE INSURANCE FUND 523930 Element Energy LLC INSURERC: SHELTER POINT POINT —8T434-- ELEMENT ENERGY SYSTEMS INSURER D: 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL SUBR POLICPOLICY NUMBER MMIDDY EFF POLICY EXP LIMITS COMMERCIAL GENERAL LIABILITY X X CL00275204 7/14/2021 7/14/2022 EACH OCCURRENCE $ 3,000,000 CLAIMS-MADE OCCUR DAMAGE TO RENTED PREMISES Ea occurrence $ 100,000 A MED EXP(Any one person) $ 5000 IMA389203 7/14/2021 7/14/2022 PERSONAL&ADV INJURY $ 3000000 GEN'L AGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 3,000,000 POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $ 3000000 POTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident F $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N 124494445 X STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE 7/13/2021 7/13/2022 B OFFICERIMEMBER EXCLUDED? 7 N/A E.L.EACH ACCIDENT $ 1,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ 1 000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ NY State DBL DBL567527 1/01/2021 1/01/2022 Statutory DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Rd THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold NY11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED �RREEPCRESENTATIVE 0 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD APPROVED AS NOTED OCCUPANCY O DATE- 045- B.P.# 4k 06' S' USE IS UNLAVi°JFUL g� FES 4 Y: WITHOUT CER T IRC. NOTIFY BUILDING DEPARTMENT AT � OCCUPANCY7R, '802 8 AM TO 4 PM FOR THE F' _OWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED PC )R POURED CONCRETE 2. =. ;r I=RAM'NG & PLUMBING 3. 4. F N CONSTRUCTION MUST BE OMPLETE FOR C.O. COMPLY WITH ALL CODES OF .; ALL � :;'•ISTRUC?ION SHALL MEET THE REQNEW YCaRK STATE & TOWN CODES REQUIREMENTS OF THE CODES OF NEW AS REQUIRED AND CONDITIONS OF YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. SOUTHOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES 6=McA.tNSa>I CnM pjEQUMED N.Y.S.DEC RETAIN STORM WATER RUpvlJl PURSUANT TO CHAPTER 236 OF THE TOWN CODE. Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0 ` Town of Southold September 27th, 2021 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Lindh Residence,2175 Pine Neck Rd. Southold, NY 11971 To Whom It May Concern; hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code,ASCE 7-16, and NEPA-70. These code requirements include the fact that the roof framing is adequate to support the additional loads from solar,panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 140 mph, 3 second gust, Exposure B with a ground snow load of 20 pound's per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads.Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure.The dead load of the heaviest solar panel assembly in this evaluation is approximately 2.4 pounds per square foot,. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Ciustra. P.E. ,` Oo AEc YO Creat Eastern Services, Inc. =fit Gs�'AiT PO Box 240 24 Harvey Rd '' n w Riverhead, NY 11901 2 z Office; 631.543.9555 �O10 103443�1P Ali Mobile 631.235.0189 FESSIO Email: jerrygiustra@gmail.com Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0 5COPE OF WORK DESIGN i DRAFTING BY: Pd ELEMENT ENERGY LLC TO INSTALL A 19.4 N SOLAR PHOTOVOLTAIC (PV)SYSTEM AT LINDH RESIDENCE, d Greenport REVI_RN 5Y J.M-NA5CEP CERTIFIE LOCATED AT 2 175 PINE NECK RD,50UTHOLD, NY 1 197 1. West 051 1 12-129 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID r1Rd THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. E 10N5 ,N pF NEW DATE REV '� 5Y5TEM RATING �P��VLO A G, 0;,per 25 19.41 kW DC STC <[/� n lW l / Fc EQUIPMENT SUMMARY ti� - � _ • �O 703443 51 QCELL Q.PEAK DUO BLK ML-G9+ 380 WATT PV MODULES '� �. / �'� 51 ENPHA5E IQ7PLU5-72-2-U5 MICRO INVERTERS �OFESS1ONP CONTRACTOR I IRONRIDGE XR100 MOUNTING SYSTEM 5MEET INDEX •40 ELEMENT ENERGY. LLC Pv-1 COVER of �' F 7470 SOUND AVE PV-2 517E PLAN 0' Peconic MATTITUCK. NY 1195 PV-3--4 ROOF PV LAYOUT PV-5 STRUCTURAL/DETAILS 8 SECTIONS I LICENSE # 43889-H PV-G 3-LINE ELECTRICAL DIAGRAM LICENSE # 52G89-ME PV-7 LABELS ® ~ W 270'090'90° E e �R° GOVERNING CODES 4„ 6"'Rv 240° Q 120° 2017 NATIONAL ELECTRICAL CODE. 210° 150° 11 -� :i Bedell CellarsQ ` PROJECT NAV 2020 RESIDENTIAL CODE OF NEW YORK STATE. 180° A5CE 7-1 6 AND NEPA-70. UNDERWRITERS LABORATORIES(UL)STANDARDS S D /� Q 05HA 29 CFR 1910.269 OCT 0 5 2021 / -- - - GENERAL NOTES PROJECT LOCATION 'L' O BUILDING DEPT U a 1 . CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT TOWN OF SOUTHOLD W THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE C U }- HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK z Z AGREE THE SAME. 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED �' � L1J C) APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. •JFt"iv�j `' •� `� z O INSPECTION APPROVALS, ETC., FOR WORK PERFORMED FROM CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, d �� ` •* _ (L = AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES tvc �: • OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. JURISDICTION. 1 1 . EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR t 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS MAINTAINING SAFETY ON THE JOB SITE DURING THE WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND HEALTH ADMINISTRATION. THIS SHALL INCLUDE, BUT ARE NOT ' CONTINUE WITH THE WORK, HE SHALL ASSUME ALL LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, t RESPONSIBILITY AND LIABILITY THEREFROM SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY 5rtffT NAME 5. ALL STRUCTURAL STEEL SHALL BE A-3G AND SHALL BE SCAFFOLDING, STAIRS, ETC.. AS WELL AS PERMANENT _ FABRICATED AND INSTALLED AS PER LATEST A.I.5.0 CONSTRUCTION. SPECIFICATIONS. - = `= COVER 12. FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALE '1, G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING (� t NYS CODES REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING + c 1. 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN CONDITIONS PRIOR TO ORDERING MATERIALS AND COMMENCING WITH WORK. � f CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS •• WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON a A 1 .I 8. THESE DRAWINGS AS IN5TRUCMENT5 OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BIBJASIS OR SOONER IF CONDITIONS WARRANT. ; PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK, THE SITE TO BE CLEARED ` ti THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY 15 TO BE Y '� LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE EXTENSIONS TO THIS PROJECT 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. PV— RESULT OF HIS WORK. AERIAL VIEW TAX MAP: 1000070000500048000 Zoho Sign Document ID: NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXY000Q60W0 LEGEND DESIGN 6 DRAFTING BY: �DaSTING UTILITY METER MAIN SERVICE PANEL ELEMENT LL NEW PV SUB—PANELS N REVIEW B 05.1 NABC29 C�RTIFIE A/C DISCONNECT COMBINER O° INVERTERS REVISIONS GND ELECTRODE ® DESCRI PfION DATE REV PV MODULE w270 a ORI&NAL je-27 202 RACKING RAIL 24 ° ®r7r__90.E O ATTACHMENT PONT 120° ---RAFTERS 210o -*—ROOF PITCH ANGLE 180o 150o BSUNRUN METER S ®VENT OPLUMBING VENT ®SKY LIGHT CONTRACTCI, ®CHIMNEY ®COMPOSITE SHINGLES GOOD CONDITION ❑POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY -EMENT ENERGY. LLC 7470 SOUND AVE MATTITUCK, NY 1195: '3" ACHED GARAGE LICENSE # 43889-H LICENSE # 52489-ME PROJECT NAME Q w O U z � _ C) w a o — W z z OF NEw z y �Q o PRO A C'ijG O,A ��' _ O * a zlnD 103443 4 A��FESSIONP� SHEET NAM`_ 51TE PLAN DRAWING SCALE CONSTRUCTION NOTES I .) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE SHEET NUMBeR MANUFACTURER'S INSTALLATION INSTRUCTIONS. PV-2 � /_ 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. I V 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. TAX MAP: 1000070000500048000 Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0 CONSTRUCTION SUMMARY — MAIN HOUSE TAX MAP: 1000070000500048000 DE51GN e DRAFTING BY: (35) QCELL Q.PEAK DUO BLK ML-G9+ 380 WATT PV MODULES ELEM`NT ENERGY LLC (DIMENSIONS: 72.4"X 40.6"X I .6") REVIEW BY J.M.NABCEP CERTIFIEC (35) ENPHA5E IQ7PLU5-72-2-U5 MICRO INVERTERS 051 1 2-129 (56)ATTACHMENT POINTS @ 64"O.C. MAX. (239.8) LF IRONRIDGE XR100 MOUNTING SYSTEM. REVISIONS ROOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) 36" FIFE 5ETBACrJACCE55 PATH I I 6�Flt SE76�CCRTAC�E55FA 1 DESCRIPTION DATE <E�- CON5TRUCTION NOTES )Rl,1,AL 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTUREIR'5 INSTALLATION INSTRUCTIONS. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH — - i - --- MINIMUM NEMA 3K RATING. 1 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE — - FIELD VERIFICATION. I LJ -' FE - - - coNrrzAcroP _._. _ - _• _ r-. p r - MENT ENERGY. LLC. ---- 7470 SOUND AVE --I - -r-r-r-r- - - - - I 1 35 MATTITUCK. NY 1 1952 LICENSE # 43889-H 1 1 1 LICENSE # 52689-ME E_�_}_. . �,- ARRAY #2 ARRAY # I - 1 t � _ i +: i 17 MODULES ! _i 19°PITCH PROJECT NAM 16 MODULES _. _ –. _ 1 r L : 72°AZ 1 9°PITCH - LITH 252°AZIMUTH o _ Q �I 1 I LLl 01� f �l � U >- pF NEIN – VV270�a 1L1 z �P�pgO A 6' 0�� 240- �90-E LLJ LLl -- - - 1 1 — 210 o 120 D z 180o1s0� p_ _ - - - O I_ V 1 1 , O 103443 -- L , A�OFESSIONP� ,T T L. I j ! — LEGEND N21-5 EXISTING UTILITY METER 36"FIRE�SETBACK/ACCESS PATH MAIN SERVICE PANEL 36 FIRE S�TBA� JA ES�PgTH AD NEW PSUB-PANELS � A/C DISCONNECT COMBINER SHEET NAME INVERTERS GND ELECTRODE PV MODULE ROOF DETAIL 3G" x 36" GROUND ACCESS TYP. _RACKING RAIL 31-211- -- ATTACHMENT POINT O-RAFTERS DRAWING SCALE f-ROOF PITCH ANGLE tSUNRUN METER 3/ 1 G" "SYSTEM SPECIFICATIONS NOTES' ®"ENT TOTAL SYSTEM SIZE: 19.4 kW 0PLUMBING VENT MODULES: (5 1) QCELL Q.PEAIC DUO 13LK-G9+ 380 PV MODULES ®SKY LIGHT SHEET NUMBER. INVERTERS: (5 1) ENPHASE IQ7PLU5-72-2-US MICRO-INVERTERS ®CHIMNEY (35) MODULES INSTALLED ON THE MAIN HOUSE ®COMPOSITE SHINGLES PV_3 GOOD CONDITION (I G) MODULES INSTALLED ON THE DETACHED GARAGE - POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0 CONSTRUCTION SUMMARY - DETACHED GARAGE TAX MAP: 1000070000500048000 DESIGN 4:DRAFTING BY (I G) QCELL Q.PEAK DUO BILK ML-G9+ 380 WATT PV MODULES ELEMENT ENERGY LLC (DIMENSIONS: 72.4"X 40.0 X I .G") N REVIEW BY J.M.NABCEP CERTIFI (I G) ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS os I z- z? 0' (24)ATTACHMENT POINTS @ G4"O.C. MAX. (I 09.G) LF IRONRIDGE XR 100 MOUNTING SYSTEM. I FEV1510N5 ROOF TYPE = ASPHALT SHINGLE (SINGLE LAYER) DEscRIFMON DATE REV CONSTRUCTION NOTES -- - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - VV270°a 90° ""A- -)a-27 I .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 240° E WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 210 D 120°150 2.) ALL OUTDOOR EQUIPMENT SHALL BE PAINTIGHT WITH ° MINIMUM NEMA 3R RATING. 180- 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE - — FIELD VERIFICATION. — - — — — — — — — — — — — — — — — — — I - -- - - - -- ELEMENT ENERGY. LLC. 7470 SOUND AVE - MATTITUCK. NY 1 195 - - J LICENSE # 43889-11 LICENSE # 52G(59-ME PROJECT NAV- ARRAY #3 6 MODULES 230 PITCH Lu O 260° AZIMUTH — - - c) U LLL �- Cl/ W Of Neiv = z -1 1-1 ; A O CO LEGEND CV EXISTING UTILITY METER 103443 �� ~ - MAIN SERVICE PANEL A�lOw`P NEW PV SUB-PANELS ss,O A/C DISCONNECT -- .-- _ .- -- .- -._. _ _- -,__ - - _ COMBINER SHEET NAME , INVERTERS '� GND ELECTRODE PV MODULE ROOF DETAIL. RACKING RAIL I _ 0 ATTACHMENT POINT 1:5q ---RAFTERS DRAWING 5Cn. -*—ROOF PITCH ANGLE 59 SUNRUN METER 114''/it'' `SYSTEM SPECIFICATIONS t NOTES' I IL ®VENT T TOTAL SYSTEM SIZE: 10.4 kW 21-2 4 0PLUMBING VENT MODULES: (5 1) QCELL Q.PEAK DUO BLK-G9+ 380 PV MODULES ®SKY LIGHT 5h1EE?NUMBER INVERTERS: (5 1) ENPHASE IQ7PLUS-72-2-U5 MICRO-INVERTERS ®CHIMNEY (35) MODULES INSTALLED ON THE MAIN HOUSECOMPOSITE SHINGLES PV-4 (I G) MODULES INSTALLED ON THE DETACHED GARAGE GOOD CONDITIONSHAD CPOTENTIALLSHADING ISSUES TRIM/REMOVE AS NECESSARY Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0 LOAD CALCULATION ARRAY#I ARRAY#2 ARRAY#3 ITEM DESCRIPTION ARRAY#1 #2 ARRAY# (RB) Rid ELEMEe Bea"E,oarci %" u DE-5iff s�f-w�5�. R" � ��� �" X NT ENERGY LLC MODULE WEIGHT(Lbs) 43.0 43.0 43.0 R Rafter5 REVIEW BY J.M.NA5CEP CERTIF! (D) Deckinci i-LY�. 05 i i i 2-i 2a #OF MODULE5 18 17 16 OF NEW (P) Pitch 23° TOTAL MODULE WEIGHT(Lbs) 774.0 731.0 688.0 �` y M Cedincl J0I5t J. F 2° �D 24" C REVISIONS A �, O (C) Collar D. FIZ a e x e` D. ')E5cRIPr10N DATE Rf TOTAL LENGTH OF RAIL(Ft) 123.3 1 1 6.5 109.6 �Q - - - � �w SGS (f1) horizontal Span of(R) -v - " ",^AY RAIL WEIGHT PER FOOT(Lbs) 0.68 0.68 0.68 [(/� NAL Ce-27-2021 TOTAL RAIL WEIGHT(Lbs) 83.8 79.2 74.5 _`� ILU #OF 5TRANDOFF5 28 28 24 m Z WEIGHT PER STRANDOFF(Lbs) 2 2 2 �Q 103443 TOTAL STANDOFF WEIGHT(Lbs) 56 56 48 ��SS1O_`PV TOTAL ARRAY WEIGHT(Lbs) 913.8 866.2 810.5 POINT LOAD(Lbs) 32.6 30.9 33.8 CONTRACTOR TOTAL ARRAY AREA(5q Ft) 374.4 353.6 332.8 ARRAY DEAD LOAD(Lbs/5q Ft) 2.4 2.4 2.4 ELEMENT ENERGY. LLC WIND DESIGN SUBJECT TO DAMAGE FROM 7470 SOUND AVE GROUND SEISMIC FLOOD WINTER ICE BARRIER AIR MEAN (P) MATTITUCK. NY 1195c. SNOW Special Windborne DESIGN Frost DESIGN UNDERLAYMENT FREEZING ANNUAL (C) Speed -Ph) effectsk Topographic wind debris r line Termite` TEMP' REQUIRED h HAZARDsg LICENSE # 43889-h LOAD' (mph) I CATEGORY Weatheringa c INDEX'' 7ENPI LICENSE # 52689-ME region 10'u- depth 20 140 NO NO NO B SEVERE 3 FT MOD TO HEAVY 15°F YES F NE X 599 51`F MANUAL)DESIGN CRITERIAn Winter SummerSummerIndoor Altitude Design Heating Elevation Latitude heating cooling correction factor design temperature cooling temperature PROJECT NAM-_ temperature difference 108 FT 41°N 15'F 86°F 1.00 70'F 75°F 55°F Wind Wind (J) Cooling Coincident Daily Winter Summer temperature difference velocity velocity wet bulb range humidity humidity heating cooling ILL_] O 11°F 15 MPH 7.5 MPH 72°F MEDIUM(M) 40% 32 GR @50%RH For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. ROOF FRAMING DETAIL n [J_J - a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength LU z required for weathering shall govern.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as determined in z from Figure R301.2(4).The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652. LL.J Q b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1),the frost line depth strength required for weathering shall govern.The jurisdiction a/ LL_[ J shall fill in the frost line depth column with the minimum depth of footing below finish grade. z O C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. MODULE MOUNTING CLAMP = _ d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(5)A].Wind exposure category shall be determined C on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Plumbing Code of New York 50LAK MODULE _z D State.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.[Also 5TAINLE55 STEEL 3/8" J O see Figure R301.2(1).] BOLT AND NUT f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. N g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a minimum,special flood hazard areas as identified by the Federal Emergency Management Agency in the Flood Insurance Study for the community,as amended or revised with: i.The accompanying Flood Insurance Rate Map(FIRM), NRIDGE ALUMINUM RAIL ii.Flood Boundary and Floodway Map(FBFM),and ALUMINUM"L"BRACKET iii.Related supporting data along with any revisions thereto. SHE`cT NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the ALUMINUM PLA5HING effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." IT RU CT U RA I. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (Base 32°F)." ASPHALT 5HINGLE ROOF k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 5/1 G"x G"5TAINLE55 jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. 5TEEL LAG BOLT WITH DRAWING SCALE 1. In accordance with Figure R301.2(5)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this part of the table with 2 1/2"MIN THREAD "YES"and identify any specific requirements.Otherwise,the jurisdiction shall indicate"NO"in this part of the table. PENETRATION 5EALPD mA5 N OT t . In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the WITH GEOCEL 4500 table. (EQUIVALENT OR BETTER) n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1 b from ACCA Manual J or established criteria determined by the jurisdiction. o. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(6)for sites at elevations up to 1,000 feet.Sites at elevations above 1,000 feet shall have their ground snow load increased from the mapped value by 2 psf for every 100 feet above 1,000 feet. 5HEET NUMBER (') See Figure R301.2(4)B. TAX MAP: 1000070000500048000 MOUNTING DETAIL Zoho Sign Document ID: NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60W0 `SYSTEM SPECIFICATIONS $- NOTES` DESIGN a DRAFTING 5Y: TOTAL SYSTEM 51ZE: 19.4 1 kW ELEMENT ENERGY LI-C MODULES: (5 1) QCELL Q.PEAK DUO 6LK-G9+ 380 PV MODULES REVI_w 5Y J.M.NAECEP CERTIFIED 05 1 1 1 2-129 5TRINGS #l -2INVERTERS: (5 1) ENPHA5E IQ7PLU5-72-2-U5 MICRO-INVERTERS r-_ ____________ _ -- -- (35) MODULES INSTALLED ON MAIN HOUSE REVISIONS - - - - - - - - - - F'] - - (I Q MODULES INSTALLED ON THE DETACHED GARAGE DESCwPTION DATE 4, -.._..;A .09 2'2J2 I I I STRING #3 IT--------------- I ---------- I I -------------- TO UTILITY GRID I I I I ;7) e:NCS J '9)MC-0 N'.`eT`F.`; BI-DIRECTIONAL CONTRACTOk 0 UTILITY METER I I I-PHASE.240 V STKING #4-5 El E3 N ELEMENT ENERGY. LLC. ' i r- -------- - - - - - - - - - - - - - - 7470 50UND AVE I ---------- ---- ---- MATTITUCr- NY 1 1 952 I `- ---- ---- ---- ---- ---- ��OF NEW�,�,Y I I � LICENSE # 43889-h I ENPHA5E BRANCH CIRCUIT CABLE TYPICAL ' O q G� 0 LI N # 5 P O CO g GSA I I I 'TOTAL(2)CONDUITS NONDUITS N (1)ROR 5TRING#4-5 / 0 I �4 703443 r - -- ARoFEssIll Q I I MAIN SERVICE PANEL ]_LJ O I AC DISCONNECT U 6 ' .o oz_s,1eo PV AC LOAD CENTER _ N / G W �L N 1 I M5TING GROUNDING Lu j ELECTRODE 5Y5TEM Z [L I I = � L1J ■ I - z O I WIRE CONDUIT SCHEDULE Z LF) ~ - CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX.CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP TIMA`:: ORIGIN DESTINATION 512E PER POLE QUANTITY DEBATE INSULATION SZ� QUANTITY INSULATION 'C�/A.; TYPE 51ZE TEMP DERAT` -STAN (� 31 O.13(51(3) 310.15(BN2a1"=. INVERTERS COMBINER PANEL AWG#10 1 G 0.8 U5E-2/PV Wire Awo#8 1 BARE .-4-`AIR I" 7000 0.65 2.4% `V `_MT :7MBINER PANEL AC DISCONNECT AWG#4 3 THWN-2 - TtiWN-2 "✓C I" r 0.87 % -)ISCONNPCT MAIN PANEL AWC#4 1 3 T.1WN-2 I TMWN-2 I/C = 0.87 C.I% ELECTRICAL NOTES -5r_c NAMF CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 1.)ALL EQLJ1PMEt1T TO BE LISTED BY UL OR OTHER NRTL. AND LABELED FOR ITS APPLICATION. #I PV Source Circuit Wire Am acct Calculation CONFIGURATION 2.)ALL CONDUCTORS SHALL BE COPPER. RATED FOP GOO V AND 90QC WET ENVIRONMENT. p y 3_LI N F n( Q 3.)WIRING. CONDUIT.AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY [NEC (Isc) '(#of strmgs)'(I.56) = 19.GG A Modules per 5trtng 1 3.9 OR 8 TO. AND LOCATED AS CL05E AS P0551BLE TO THE NEAREST RIDGE. HIP.. OR VALLEY. AWG#I O. ampaaty'Temp berate = 26.88 A 26.88 A > 19.GG A. therefore DC were size Is valid. Modules per Inverter I 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 51 COMPLY WITH NEC I 10.2G. #2 Inverter Output Wire Ampaaty Calculation 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL Inverter Max Amperage output' (1.25) = 77.14 A Record low tem -1 OQC FURNISH ALL NECE55APY OUTLETS. SUPPORTS. FITTINGS AND ACE550RIE5 TO FULFILL AWG#4. ampacity'(Temp De rate)*(Cond uit Fill Derate) = 82.25 A Voc Temp Coefficient -0.24%/`'C DRAWING SCA,t APPLICABLE CODES AND STANDARDS. 82.25 A > 77.14 A.therefore AC wire size Is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS G.)WHERE SIZES OF JUNCTION BOXES. RACEWAYS. AND CONDUITS ARE NOT SPECIFIED. #3 Inverter Output Wire Ampaaty Calculation Operatinq Current I C.0 A =(#of strm s)'(Im ) N .T. . THE CONTRACTOR SHALL 51ZE THEM ACCORDINGLY. Inverter Max Am era a output' (I.25) = 77. 4 A 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. p g p O eratm Volta e 37.9 V =(#modules In series)'(Vm ) 8.)MODULE GROUNDING S SH LL BE INSTALLED BETWEEN MODULE FRAME AND MODULE AWG#4. ampaaty'(Temp Derate)'(Condwt FIII Derate) = 82.25 A Max. System Voltage 49.3 V = (#modules In series)'[(((-#.##%V/QC'.O 1)'(Lo Temp##QC-25))'(Voc))+(Voc)] 82.65 A> 77.14 A. therefore AC wire size Is valid. SUPPORT RAIL. PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Short Circuit Current 1 3.1 A =(#of sten s)'(Isc)'(I.25)per Art. G90.8(A)(1) 9.)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEED LUG AC SYSTEM SPECIFICATIONS SHEET NUMBEP OR ILSCO G5L-4D8T LAY-IN LUG. Max AC Output Current 77.14 A FV /- O.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(positive/negative) O eratm AC Volta e 240 V v �j OR 10.)THE DC 51DE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. TAX MAP: 1000070000500048000 Zoho Sign Document ID:NWVHHFHKUYXHGGTWQX3CLPNQNNDEQPQEHXYUQQQ60WO SERVICE METER OI O I� DE51GN$DRAFTING BY: INSTALLATION NOTE ELEMENT ENERGY LLC SOLAR PV SYSTEM I PHOTOVOLTAIC f • • • REVIEW 6Y J.M.NABCEP CERTIFIE 3 SOLAR ' ( I ) ALL LABEL SHALL BE INSTALLED IN D51 � .z-IzQ EQUIPPED WITH • ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ® •' " •URRENT ' REQUIREMENTS. rzevisloNs OP RDE5CR7 PilON DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND MAX SYSTEM VOLTAGE VDC SOLAR AC LOAD CENTER - OUTSIDE �DONOT RELOCATE PIS: O• REQUIRE FIELD VERIFICATION. OVERaURRMoEnCE ' (3) LABELS, WARNING(5) AND MARKING 0 TURN RAPID SHuroowNSWITCH To g Q SHALL BE IN ACCORDANCE WITH NEC THE'OFF POSITION To SHUT Dowty 0 I 1 0.2 1 (b). -- - . I PV SYSTEM AND REDUCE CAUTION WU HAZARD 11 THE ARRAY AC DISCONNECT °OWERTOT SERVCE18AMSF°"® (4) THE MATERIAL USED FOR MARKING - FROM TW OWCONE""O°"1ED AS tNO"" MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - IN51DE 2 U71­ coNTRACTOR (y w„�R COMPLIANCE WITH NEC 1 10.2 1 (3)(3). P:NU (5) THE PV SYSTEM CIRCUIT CONDUCTORS ® O7 ® I I a ARNIN WARNING SHALL BE LABELED INSTALLED IN ELEMENT ENERGY, LLC. THIS EQUIPMENT FED BY MuLnPLE SOURCES TOTALRATMIGOFALL DUAL POWER SUPPLY *% COMPLIANCE WITH NEC 690.3 I . 7470 souND AVE OVERCURRENT DEVICES ExCLUDMIc SouRCES:UTILITY GRID — __ _ MATTITUCK, NY 1 1 95 MAIN SUPPLY OVERCURRENT AND PV SOLAR LICENSE # 43(589-H DESH�ALLN ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING LICENSE # 52689-ME Q3 _ k,VARNING IS ALSO SERVED BY THIS SERVICE METER ARN I N I A , PROJECT NAME ELECTRIC SHOCK HAZARD I PHOTOVCILTAIC SYSTEM PHOTOVOLTAIC SYSTEM TERMINALS ON THE UNE AND COMBINER PANEL LOAD SIDES MAY BE ENERGIZED DO NOT ADD LOADS Q CONDUIT - OUTSIDE BUILDING I"TMEO�NPosITION Q 0 ® Q) !\WARNING LLJ DUAL POWER SUPPLY W ISOURCES:UTILITY GRID AND i � W Z PV SOLAR ELECTRICSYSTEM MAIN SERVICE PANEL - OUTSIDE CL/ lLJ OA CAUTION SOLAR CIRCUIT Z J 5 � tL = A CAUTION z 0 SOLAR ELECTRIC SYSTEM CONNECTED _l l O • • • N MAIN SERVICE PANEL - INSIDE MARNING .. ,. ., •, �• A\ NEW yO POWER SOURCE ,`Q' R0 A G'� OUTPUT CONNECTION CO ® O DO NOT RELOCATE THIS S� SHEET NAV' OVERCURRENT DEVICE LU LABELS 3 !� AC DISCONNECT/B1034 SSREAKER �OARO ;ONP�' DRAWING SCALE FE (1)(D N .T.S. SHEET NUME,`, PV-7 TAX MAP: 1000070000500048000