Loading...
HomeMy WebLinkAbout46863-Z �o�S�FFO( rt Town of Southold 2/2/2022 y� P.O.Box 1179 y z 53095 Main Rd Way o� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42736 Date: 2/2/2022 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2025 Oaklawn Ave., Southold SCTM#: 473889 Sec/Block/Lot: 70.-3-22.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/15/2021 pursuant to which Building Permit No. 46863 dated 9/23/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mount solar panels to existing single family dwelling as applied for. The certificate is issued to Dapolito,Andrea&Saccente,Joseph of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46863 12/10/2021 PLUMBERS CERTIFICATION DATED ori ed ut Signature ��o�SUFeoi,r�oTOWN OF SOUTHOLD aye BUILDING DEPARTMENT y TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46863 Date: 9/23/2021 Permission is hereby granted to: Dapolito, Andrea 64 Hudson Rd Bellrose Village, NY 11001 To: Install roof mount solar panels to existing single family dwelling as applied for. At premises located at: 2025 Oaklawn Ave., Southold SCTM #473889 Sec/Block/Lot# 70.-3-22.2 Pursuant to application dated 9/15/2021 and approved by the Building Inspector. To expire on 3/25/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ADDITION TO DWELLING $50.00 Total: $200.00 Building Inspector oF so�ryQl � o Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 Q sean.deviine-town.southold.nv.us Southold,NY 11971-0959 'Q �ycouff ' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Andrea Dapolito Address: 2025 Oaklawn Ave city: Southold st: NY zip: 11971 Building Permit#: 46863 Section: 70 Block: 3 Lot: 22.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Trinity Solar License No: 57843ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 9.86kW Roof Mounted PV Solar Energy System w/ (29) Qpeak Duo BLKG6-340W Panels , 42A AC Disconnect, PV Rapid Shutdown Notes: Solar Inspector Signature: Date: December 10, 2021 S.Devlin-Cert Electrical Compliance Form D �o�soUly AU? Town Hall A�lei; 1 5 202 l� J� Telephone(631)765.1802 54315 Main Roadm�:ax(631)765=gg5�2 P.O.Sox 1179 G� i� roger.richert(agtown.southo d.ny.us Southold,NY RUIWiNG DEPT. TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN OF SOUTHOID APPLICATION FOR ELECTRICAL. INSPECTION. REQUESTED BY: Date: Company Name: 1 � Name: License.No.; Address:. Phone No.: 6\/ JO.BSITE.INFORMATION: (*Indicates required information)' *Name;. . . *Address:. - -e . naAlyck �} . .. .` :\.. .. *Cross.Street: *Phone'No,.: Permit No:: : Tax Map District: 1.000 Se Ian;.O pBlock: b p C> Lot: p 22 Co-1 *BRIEF DESCRIPTION OF WORK (Please Print Clearly) te1S (Please Circle All That Apply) *Is job ready for inspection: YE Rough In Final *Do you need a Temp Certificate: YE O Temp Information (If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 40.0 Other *New Service: Re-connect Underground Number of'Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form i°� "l r l J 0FS0(/TyO� Ll 2_0 Z-5 OP-Pe-L,4 `iV fes' # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING]STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION- . } FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ' ] CODE VIOLATION ] PRE C/O REMARKS: L DATE 94 INSPECTOR # TOWN OF SOUTHOL-D BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATIOWCAULKING'-. [ ] FRAMING/STRAPPING [ FINALP - -[ ] FIREPLACE & CHIMNEY [ } FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL)- [ ] CODE VIOLATION [ ] PRE C/O REMARKS: Ct� - ' DATE 25 ��Z INSPECTOR o�aUE50UTyo � b��3 l� 0 TOWN-OF SOUTHOLD BUILDING DEPT. 765-1802 .. INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG: [ ] FOUNDATION 2ND [ ] -.INSULATIOWCAULKING - [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE-RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [M, ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS; DATE f INSPECTOR • FIELD INSPECTION REPORT DATE COMiVI .NTS b FOUNDATION(IST) . � O Ct FOUNDATION'(2ND) kr1 ROUGH FRAMING:& c 1 PLUMBING' N � N . • r INSULATION.PER.N.Y. H. STATE ENERGY CODE FINAL r1 • ADDITIONAL COMMENTS : CPU- 0 m' l z � y r TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 G/ Survey SoutholdTown.NorthFork.net PERMIT NO. O(O Check Septic Form N.Y.S.D.E.C. D Trustees v n C.O.Application V Flood Permit Examined ,20 Single&Separate SEP 1 5 2021 Storm-Water Assessment Form Contact: Approved • ��• ,20 BUILDING DEQ• Mail to: Disapproved a/c TOWN OF SOUTHOLD Phone: 631-319-7233 Expiration ,20 Building Inspector APPLICATION FOR BUILDING PERMIT Date 920 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. Samuel Maoliaro (Signature of applicant or name,if a corporation) 21805th Ave-Unit 1A Ronkonkoma NY 11779 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Agent Name of owner of premises Joseph Saccente (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. H-52821 Plumbers License No. Electricians License No. - Other Trade's License No. 1. Location of land on which proposed work will be done: 2025 C�aklawn Ave Southold House Number Street Hamlet County Tax Map No. 1000 Section 07000 Block 0300 Lot 022002 10 -3 490?,e:�'- Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost $49,3000 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 2025 Oaklawn Ave 14.Names of Owner of premises Joseph Saccente Address Southold NY 11971 Phone No. 516-458-8583 Ihor Bo can 21805th Ave-Unit 1A 631-319-7233 Name of Architect J Address Ronkonkoma NY 11779 Phone No 2180 5th Ave-Unit 1A Name of Contractor Trinity Solar/Samuel Magliaro Address Rnnknnknma NY 1177A Phone No. 631-319-7233 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES - NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * T YES, D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covbnants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) Samuel Magliaro being duly sworn, deposes and says that•(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Agent (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20,2f KRISTINE KRA IM Yar N[lQualified try Public otary u lic No.01K z�os7z S ature o pplicant in Suffoik County omm.Expires Oct.22,2024 1 ® D �oFSo�Py c�p Town Hall Ash, � 5 202 8 tLG Telephone(631)765-1802 54375 Main Road N � Fax(631)765-9g512 P.O.Boa 1179 { R, ® roger.richert(agown.southo d.nV.us Southold,NY IMM-, 6N 'DEA PT. TOWN OF SOUTROLD MUNi`1,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: 4 JSO`a r+ & Name: License No.: E Address: Phone No.: "® MQ o, .' c Cpm JOBSITE INFORMATION: (*Indicates required information) *Name: C *Address: \kcm *Cross Street: *Phone No.: Permit No.: Tax Map District: 1000 Se Ion: C5 Q OBlock: 63p`, Lot: b 2?__ 06 Z *BRIEF DESCRIPTION OF WORK (Please Print Clearly) N.y�r1� yea CCC , k0,T`c� kcs� (Please Circle All That Apply) *Is job ready for inspection: YE Rough In Final *Do you need a Temp Certificate: YE O Temp Information (If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form 1 1,07 AREA— 42.813 rq !L 1.ot HUNtf�N t1 LUr fvUMBE>y 13 5 301 u'> n h 9 J { CY 34 4 3 RT— Li ba[1LI/a T i V] ka l 1 to I J z I i ` fI N 2J`23'50'W T25.00' OAKLAWN AVENUE !*'G E: CFSSFWI, SE'-MC TMX do WATER SZRV10E L0cAncNs sY oTriERS_ ®--22-2002 FINAL SURVEY ++ar a�aawrx of alarr a►wn aND M wiyan� 5-4-2002 LOCATED FDUNOA71ON ar W=211L r Wr,mor MOM Aff Nor.,^WMM 4-3-2002 REMSED D%*LUNC W 0"sm Rai miadnoo sKM"own MOW m swaxAm sa M[ p"OpUry MNsa AN pm a mnww ptwcw mm At 4o Nmam An uo1 ro JOB No. 01-617 a"rnsa suc w"w"v rums m� w wa rua Ia►r,ma FILE No. PECONfC DEWL CORP. SURAYM FCR DAME) W. & JENNIFER W, OLSF-N ,sr aurnc.-W rQ =KA1 ro >sft siWaY a naAruN or LOT NUMBER 2 racy or mt.cn>a�rrv,<®crwnti+qac W OF PECONIC DEVELOPMENT CORP. AT %OUTNc)LO YtrMMctiY's iNYJ[7�3D mmSMll INN akyr M h!R'7Qr7f Pita IRCY ML as"r n mrwcm wa a>;m rowr m 1A[>ru ocrrvrr.atowrnrm SITUATED AT SOUTH= aczirr ono tea O mrwm Isim Nem 03 To W mm=aa a W Gb400 iNUrVQ r ft~"M AM NOT TOVSH MA A aoa"°"&'amum"s cb ZJRMA2 a o>w M TOWN OF SOUTNOID — SUFFOLK COUNTY N.Y, COM O n4c"4t7 rat WX KWA M taala=rae 2 toren s[x 04 SCM.E i' o 50' DATE 12-20-2001 CaX4"srx W^L NOT O=MCW"A WAWa"M W". PLED MNo. 1072.E DATE 12-27-2001 CE:R71F1ED ONLY TC} AF TAX LW No.(ArF ONLY) 1000-70-3-22.2 OISK 5O0 C,1J'0 W. & JE.1JNiFE.4 W, t�LN sl +;srsF A-R'T-RAcr PIC, HAROLD F. TRANCHON JR. P.C. �y EA NO SURVEYOR 1666 WA ONC RIVE YORK. NIOR RD, WADING RIVER, t NEW N."Y. LIC. Na. 046992 ORK. 11792 WtROLD F 7RANCNON JR. PENN. LIC. Na. 2115—E 631--929-4695 1Workers' CERTIFICATE OF ATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Trinity Solar Inc. 631-319-7233 2180 Fifth Avenue,Unit 1A Ronkonkoma,NY 11779 1c.NYS Unemployment Insurance Employer Registration Number of Insured - 49-230977 Work Location of Insured (Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) National Union Fire Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"1a" Southold NY 11971 WC 013588107 3c.Policy effective period 06/01/2021 to 06/01/2022 3d.The Proprietor,Partners or Executive Officers are ❑✓ included.(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form, New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in.effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business,continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is-complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Michael Price (Print name of authorized representative or licensed agent of insurance carrier) Approved by: tp 06/04/2021 (Signature) (Date) Title: CEO North America Telephone Number of authorized representative or licensed agent of insurance carrier: 212-770-7000 Please Note: Only insurance carriers and their licensed agents are authorized to issue Form C-105.2. Insurance brokers are NOT authorized to issue it. C-105:2 (9-17) www.wcb.ny.gov AC40® DATE(MMIDDNYYY) V CERTIFICATE OF LIABILITY INSURANCE 9/10/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Mark Grasela Arthur J.Gallagher Risk Management Services, Inc. P" Ext): 856-482-9900 /c No):856-482 WC�NN . F , -1888 4000 Midlantic Drive Suite 200 E-MAIL Mount Laurel NJ 08054 ADDRESS: Cher Hill.BSD.CertM AJG.com INSURERS AFFORDING COVERAGE NAIC# INSURER A:Gotham Insurance Company 25569 INSURED TRINHEA-03 INSURER B:National Union Fire Insurance Company of Pittsburg19445 Trinity Solar Inc. 2180 Fifth Avenue, Unit 1A INSURER C:Endurance American Specialty Ins Co 41718 Ronkonkoma, NY 11779 INSURER D: Liberty International Underwriters INSURER E: INSURER F; COVERAGES CERTIFICATE NUMBER:1748803206 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP LIMITS LTR I D WVD POLICY NUMBER MM/DD MMIDD/YYYY A X COMMERCIAL GENERAL LIABILITY GL202100013378 6/1/2021 6/1/2022 EACH OCCURRENCE $2,000,000 � OCCUR DAMAGETO S(RENTED CLAIMS-MADE PREMISES Ea occurrence) $100,000 MED ERCP(Any one person) $5,000 PERSONAL 8 ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 JE� LOC PRODUCTS-COMP/OP AGG $2,000,000 POLICY 1K OTHER: $ B AUTOMOBILE LIABILITY CA 2960145 6/1/2021 6/1/2022 COMBINED SINGLE LIMIT $2,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident A UMBRELLALIAB X OCCUR EX202100001871 6/1/2021 6/1/2022 EACH OCCURRENCE $5,000,000 D X EXCESS LIAB ELD30006989100 6/1/2021 6/1/2022 CLAIMS-MADE 1000231834-05 6/1/2021 6/1/2022 AGGREGATE $5,000,000 DED I I RETENTION$ Limit x of$5,000,000 $19,000,000 g WORKERS COMPENSATION WC 13588107 6/1/2021 6/1/2022PER I OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE I I ER ANYPROPRIETOR/PARTNER/EX-E uTIVE E.L.EACH ACCIDENT $1,000,000 OFFICERIMEMBEREXCLUDED? NIA (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 B Automobile CA 2960146 6/1/2021 6/1/2022 All Other Units $250/500 Comp/Collusion Ded. Truck-Tractors and Semi-Trailers $250/500 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Southold 54375 Route 25 Southold NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family-Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b. Business Telephone Number of Insured TRINITY SOLAR INC. 2180 FIFTH AVENUE, UNIT 1A 631-319-7233 RONKONKOMA, NY 11779 Work Location of Insured(only required if coverage is specifically limited to 1 c. Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 22-3292324 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Com an of New York Town of Southold Y P Y 54374 Route 25 3b.Policy Number of Entity Listed in Box"1a" Southold, NY 11971 R71757-000 3c.Policy effective period 7/1/2013 to 6/1/2022 4. Policy provides the following benefits: 0 A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as descpqbd above. Date Signed 9/10/2021 By �&A. �?444(&t (Signature of insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers' Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (only if Box 4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. 1313-120.11 (10-17) 111 Jill DB-120.1 (10-17)i'1111111 f Suffolk County.Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name WILLIAM F.CONDIT Business Name This r is certifies licensed e 'T,RINITY HEATING&AIR INC DBA bearer is duly licensed _ by the County of suffolk License Number:H-52821 Fra'^k'N°'deUv Issued: 01/29/2014 Commissioner Expires: 01/01/2022 � J a Suffolk County Dept.of r Labor,Licensing&Consumer Affairs r MASTER ELECTRICAL LICENSE Name j RICHARD GUANERI Business Name This Certifies that the bearer is duly licensed Trinity Solar Inc. by the County of Suffolk License Number:ME-57843 Rosalie Drago Issued: 12/15/2016 Commissioner Expires: 12/01/2022 SGCCe�e i ��� ao Cv1 auyc Ave Mrinitv SOLAR �eCQ- a jyy Permit Application Checklist: Southold TSEG Forms own Application (legal paper) ✓ lectrical Application f SM Application for Certificate of Occupancy/s Vyi Sets of Plans ,E6 4 PE Letter(s) l Contractor's Insurances -cYbAr e-cA Contractor's License Suffolk Electrician's Suffolk License MO Filing Fee +�o,p , ca�f s�,urruey L7 Copies of Spec S eets, Inverters/ Panels and Racking ayyrea bQ96c 5 eO 1�t-[-mosso C} X300 ?tea- �1ernwlnc� 3�CQ.P k SO-Cce(\k S oa o �ea �o�aC� o ' u3ov C)-26 U Z 1 (T'�H)n t v SOLAR Southold Town, NY December 8, 2021 Town Hall Annex Building54375 Route 25 P.O. Box 1179 Southold, NY 11971 RE: ANDREA DAPOLITO; JOSEPH SACCENTE Trinity Solar No. 2025 Oaklawn Avenue 2021-06-593770 Southold, NY 11971 To the Building Official: I hereby certify that I am a Licensed Professional Engineer in the State of New York. The solar photo-voltaic (PV) system installed at the above-referenced location conforms to the manufacturers' requirements/specifications. The PV system complies with all applicable laws, codes and ordinances as specified by all applicable codes, including 2020 Residential Code of New York State and the 2018 IRC. Regards, Thor Bojcun, PE Structural Engineer-Trinity Solar ,\p� `!\%CtAE4 e0 r� l4 S CL VP \�E_SSION}`� NY License No.095675 Trinity Solar 12180 5th Avenue,Unit 1 1 Ronkonkoma,NY 1(631)319-7233 Date: March 2nd, 2022 Southhold Town, NY Town Hall Annex Building 54375 Route 25 P.0 Box 1179 Southold, NY 11971 RE: Permit#: 46863 Section: 70 Block: 03 Lot: 22.2 To Whom It May Concern, The original plans for Joseph Saccente of 77 2025 Oaklawn Avenue, Southold, NY 11971 have been changed due to panel count decreased from 32 panels to 29 panels, and panel layout revised on array 2, array 5 and array 6. The As-Built drawings that we are submitting for approval are actual layouts of the roof and equipment. If you have any questions or need further assistance, please call our office. Thank you, Trinity Solar Lana Harrinanan: 631.319.7233 (ext. 1326) 1 nTT'lr- i n 'I t V SOLAR Southold Town, NY August 26, 2021 Town Hall Annex Building54375 Route 25 P.O. Box 1179 Southold, NY 11971 RE: ANDREA DAPOLITO; JOSEPH SACCENTE Trinity Solar No. 2025 Oaklawn Avenue 2021-06-593770 Southold, NY 11971 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic[PV] system on the existing roof framing components at the above-referenced location. Criteria is as follows: 1. Existing roof framing: Conventional roof framing is 2x8 at 16 o.c.; maximum existing rafter span= 13'0"; (horizontal projection) 2. Roof Loading: • 4.33psf dead load (pounds per square foot- PV panels, mounting rails & hardware) • 6.3 psf-existing roof loads (2.3 psf-2x8 framing, 1.5psf roof sheathing, 2.5 psf shingles) • Ground Snow Load-20psf- per AHJ (Authority Having Jurisdiction) • Wind criteria- Exposure Category B, 128 mph wind equivalent to 23.09psf wind pressure 3. Existing Roof modification - none required; existing roof framing is acceptable for PV installation. The installation, described above, is in general conformance with the manufacturers'specifications and complies with all applicable laws, codes, and ordinances as specified by applicable codes, including the 2020 Residential Code of New York State. The spacing of the mounting brackets cannot exceed a maximum of 48"o.c. between mounting brackets and will be fastened using 5/16"diameter corrosive-resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter(4" long lag bolts required)and a minimum 2'/2" penetration (embedment)of all bracket lag bolts beyond the roofing materials; this is adequate to resist all stated live loads above—including wind shear. Per NDS Section 11.1.4, pilot holes not to exceed-one-half the diameter of the shank need to be bored into the primary framing members for the full length of the threaded portion of the screw to avoid splitting of the framing member. Stainless steel lag bolts are required. Regards, Ihor Bojcun, PE pF l��yy Structural Engineer-Trinity Solare0 r0� SU a.A CG 0 � 4r 095b75 R"'Es"S 10191" NY License No.095675 Trinity Solari 2180 5th Avenue,Unit 1 I Ronkonkoma,NY I(631)319-7233 EcoFasten For Installers By Installers COMPLETE RAIL-BASED RACKING SYSTEM ClickFit is one of the fastest installing rail-based systems in the industry. Thanks to its Click-In rail assembly, the Composition Shingle, Tile,Metal rails can be connected to any of EcoFasten's composition shingle, tile, and metal roof mounts in seconds without the need for fasteners or tools. The Click Fit system is made of robust materials such as albminum and coated :::: Rail-Based steel, to ensure corrosion-resistance and longevity. ClickFit conforms to UL 2703 and has been tested in extreme weather conditions including wind, fire, and snow. Structural-Attach FEATURES & BENEFITS Direct-Attach • Tool-less,fastener-free rail attachment • Fully integrated bonding • Click-On Mid&End Clamps • Compatible with a variety of EcoFasten roof attachments FAST INSTALLING SYSTEM FEATURING 25 YEAR WARRANTY CLICK-IN RAIL ASSEMBLY j t � rim F INTERNAL SPLICE Tool-free bonded internal Splice installs in seconds. MLPE MOUNT Attach Module Level Power MID CLAMP Electronics to the top of the rail. Click-on mid clamp features integrated bonding pins and fits modules 30-50 mm in width. END CLAMP Click-on end clamp fits modules END C A P 30-50mm in width. The slide-on end caps allow the end clamps to be accurately positioned on the rail in seconds, while providing an aesthetically- pleasing, finished install. L-FOOT The ClickFit rail simply clicks into our proprietary composition shingle & the L-foot without the need to use fasteners or tools. COMPOSITION RHINGI._ - Combine the versatile ClickFit L-Foot with the watertight GF-1 flashing for a fast installation on composition shingle roofs. GF-1 FLASHING&L-FOOT i ILL GOOFS Use the adjustable ClickFit Tile Hook for attaching the ClickFit „ system to tile roofs. Works with Flat, S, and W tile profiles. J CLICKFIT TILE HOOK STANDING SEAM METAL ROOFS Combine the ClickFit L-Foot with SimpleBlock�-U for a fast installation on standing seam metal roofs. SIMPLEBLOCK-LI PRODUCT PART PART BOX PALLET IMAGE NUMBER DESCRIPTION QUANTITY QUANTITY ASSEMBLED WITH(1)OF GROMMET AND INCLUDES(1)5/16-EPDM BONDED WASHER - GF1M GAL BLK 810 GIFT 8X70"BLK GLV 50 W/2"HL PLCMT - GF1 GAL BLK 612 GF1 8X12"GALVALUME BLK 50 (LASHING ALL HARDWARE INCLUDED OO 1500004 CF NO R3WAR ASSY 100 5000 1500005 CF TILE HOOK US 20 480 t 1510045 CF TILE HOOK SUB-FLASHING 20 2160 TILE HOOK FLSH-F ST TILE HOOK FLASH 12 576 FLAT SIERRA TAN TILE HOOK FLSH W ST TILE HOOK FLASH 12 576 W SIERRA TAN TILE HOOK FLASH 12 576 TILE HOOK FLSH-S ST S SIERRA TAN INCLUDES O• :O SIMPLEBLOCK-U-AL 2"SIMPLEBLOCK SSR-AL 2C 44CC ALL HARDWARE INCLUDED WITH OO 1500004 CF L-FOOT ASSY 50 5000 NO�AROWARE NEECEE' 1500033 CF RAIL 2T) N/A 108 (-7 FT) 1500034 CF RAIL 4 FT) N/A 108 [-10.4 FT) 1500035 CF RAIL N/A 108 (-13.8 8 FT)FTJ 1008061 CF RAIL SPLICE 100 3200 1510070 CF WIRE MGMT CLIP 1000 TBO 7 MODULE JUMPER,6 IN 1500028 (204MM1 25 25000 1510057 CF MLPE MOUNT 400 17600 PRODUCT PART PART BOX PALLET IMAGE NUMBER DESCRIPTION QUANTITY QUANTITY 1510041 OF BLK LABELED uu 1510015 OF HO ENOCLAMP J ­1AJ 1 30MM,BLK 1510016 OF HO ENOCLAMP 5C 5600 32MM,BLK 1510017 OF HO ENOCLAMP 50 5600 35MM,BLK 1510018 OF HO ENDCLAMP 50 5600 38MM,BLK 1510019 CF HO ENOCLAMP 50 5600 40MM,BLK 1510020 OF HD ENOCLAMP 50 5600 45MM,BLK 1510011 OF HO MIOCLAMP 50 5600 30-40MM,BLK 1510012 OF HO MIOCLAMP 50 5600 40-50MM,BLK ROCK IT V3 SKIRT A65 ROCK-IT SKIRT V3 a 256 35MM&40MM 65" ROCK-IT V3 SKIRT A79 ROCK-IT SKIRT V3 8 255 35MM&40MM 79' ROCK-IT V3 SKIRT A80 ROCK-IT SKIRT V3 8 256 35MM&40MM 80" ROCK-IT V3 SKIRT 865 ROCK-IT SKIRT V3 8 256 32MM&38MM 65" ROCK-IT V3 SKIRT 879 ROCK-IT SKIRT 79 8 256 32MM&38MM 79" ROCK-IT V3 SKIRT 880 ROCK-IT SKIRT V3 8 256 32MM&38MM 80 i11,11 Vill I 1500003 OF UNIVERSAL SKIRT 50 5750 CLAMP BLK POLY KIT LAG SCREW 4 POLY KIT LAG 50 480 SCREW 4"(50) SCRW OP 15-13X03 ROOFING SCRW 1000 60000 #15 X 3"DRILL PT INCLUDES :i 1510001 CONDUITMOUNT-BRKT 50 10350 INCLUDES(1)SS B-18 X 314-TEK SCREW CONOUITMOUNT-TILE CONDUIT MOUNT-TILE SYSTEM 60 4320 �,:;S_Urt i r ■ ECOFASTEN SOLAR EcoFasten has an established a reputation for being one of the industry's leading innovators by providing expert solutions for mounting solar PV on any type of roof. Our broad portfolio of solutions stem from the needs of, and direct inputs by solar PV installers. We take pride in providing the right solution for every application. We educate our customers, so they purchase the best, most cost-effective solutions to fit their needs, and we complement that with on- site installation training to ensure 100% satisfaction. We are honest with ourselves, our customers, and our employees, fostering a culture of idea-sharing, innovation, and creativity. N n ECOFQSte4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 w An ESDEC Company 1 - 877 - 859 - 3947 1 INF0@EC0FASTENS0LAR . 00M Single Phase Inverter Z • HID-WaveC with m for North America PO SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE10000H-US / SE1140OH-US '..'.' O X LA O O o • o • O solarZ.y:C <<) solarZU"- • O • IL -- -- • O a - - O 0 o O Optimized installation with HD-Wave technology / Specifically designed to work with / UL1741 SA certified,for CPUC Rule 21 grid compliance power optimizers / Record-breaking efficiency / Extremely small Quick and easy inverter commissioning directly guilt-in module-level monitoring from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article / Optional: Revenue grade data,ANSI C12.20 690.11 and 690.12 Class 0.5 (0.5% accuracy) solaredge.com solar=@ " Sin le Phase Inverter Wit HD-Wave Tec n0 ogy for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH XXXXXBXX9 OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max- ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ Vac ;183-208-229) AC Frequency;Nominal) 59.3-60-605Hz Maximum Continuous Output 123 16 21 25 32 42 475 A Cu,rent @240V Maximum Continuous Output Current @2088 6 24 48.5 A Power Factor 1,adjustable-0.35 to 0.85 GFDIThreshold 1 A U?ili?y Monitorng,Islanding Protection,Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V' 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V' 9 13.5 - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ksi Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @ 2408 % 98.5 @ 2088 Nighttime Power Consumption <2.5 W For other regional settings please contact SolarEdge support A higher current source may be used;the inverter will limit its input current to the values stated Sin le Phase Inverter Wit HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional, Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection Rapid Shutdown-NEC 2014 and 2017 590 L Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL16998,CSA C22.2,Canadian AFCI according to TI.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emrsions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG P'Maximum/14-4 AWG DC Input AWG Range 1"Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG T'Maximum/1-3 strings/14-6 AWG 9 Dimensions with Safety Switch 17 7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 In/ (HxWxD) mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38.8/17.6 Ib/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60" T/-C Protection Rating NEMA 4X(Inverter with Safety Switch) Revenue grade inverter P/N:SExxxxH-USOOOBNC4 4Full power up to at least 50'C/122'F,for power de-rating information refer to.https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf O SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge in Technologies,Inc All Ro H S other trademarks mentioned hereare trademarks of their respective owners.Date.5/2019N01/ENG NAM.Subject to change without notice. powered by i� \ TOP BRAND PV EUNOIE 2019 CICELLS secuw.v ouauty rested ww.VDEM.— ID.40032587 Q.ANTUM TECHNOLOGY:LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area,lower BOS costs,higher power classes,and an efficiency rate of up to 19.5%. INNOVATIVE ALL-WEATHER TECHNOLOGY C?, Optimal yields,whatever the weather with excellent low-light and temperature behaviour. �- ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID Technology',Hot-Spot Protect and Traceable Quality Tra.Qt"'. EXTREME WEATHER RATING 17) High-tech aluminium alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). C A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty'. STATE OF THE ART MODULE TECHNOLOGY r' Q.ANTUM DUO combines cutting edge cell separation i and innovative wiring with Q.ANTUM Technology. APT test conditions according to IEC/TS 62804-1.2015,method B(-1500V,168h) See data sheet on rear for further Information, I(THE IE THE IDEAL SOLUTION FOR: "ll/ Rooftop arrays residential buildings Engineered in Germany CELLS MECHANICAL SPECIFICATION Format 1740mm x 1030mm x 32mm(including frame) Weight 19.9kg 980 3p0" Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film eel,m� Frame Black anodised aluminium Cell 6 x 20 monocrystalline Q.ANTUM solar half cells ® imomm Junction box 53-101 mm x 32-60 mm x 15-18 mm Protection class IP67,with bypass diodes ,,,, Cable 4 mm2 Solar cable;(+)a1150mm,(-)z1150mm Connector Staubli MC4,Amphenal UTX,Renhe 05-6,Tangling _ ,.GwMnO bx NETAI AI } TL-Cable01S,JMTHY JM601;IP68 or Friends PV2e;IP67 »I r 31mm DEi4Ls 11 8 i N.Smm I�TA6,mn ELECTRICAL CHARACTERISTICS POWER CLASS 330 336 340 346 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) Power at MPP' Pv11 [W] 330 335 340 345 Short Circuit Current' Is_, [A] 10.41 10.47 10.52 10.58 EE Open Circuit Voltage' V,,; IV] 40.15 40.41 40.66 40.92 E Current at MPP 1-1 [A] 9.91 9.97 10.02 10.07 E Voltage atMPP VMS, [V] 33.29 33.62 33.94 34.25 Efficiency' q [%] >-18.4 >_18.7 219.0 119.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT1 Power at MPP PM [W] 247.0 250.7 254.5 258.2 E Short Circuit Current I- [A] 8.39 8.43 8.48 8.52 E Open Circuit Voltage V, [V] 37.86 38.10 38.34 38.59 c f Current at MPP I- (A] 7.80 7.84 7.89 7.93 Voltage at MPP V.,,__ [V] 31.66 31.97 32.27 32.57 'Measuremen,'olera,,.2s?,,,,,:±3%;I,;:,V 51/a'STC.1333 W/m'.25,2'C,AM 1.53 according to IEC 60904-3. 800 W/m2,NMOT,spectrum AM 13G 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ------ -___i___--, v At least 98%of nominal power dur- = ww 9 Y:.n_._._=s:x.".-__._..._._._. in first ear.Thereafter max.0.54% z r _ _ degradation per year.At least 93.1% W of nominal power up!o 10 years.At W LL F z e "--"------" least 85%of nominal power up to W Eg >25 years c a - - -- ------ ¢oz , S --- oAll data within measurement toler- ances.Full warranties in accordance o as with the warranty terms of the Q00 �0° i0° AO0 100° fIRRADIANCE IW/mil o Q CELLS sales organisation of your u „ respective country. YEARS Typical module performance under low irradiance conditions in comparison to STC conditions(25°C,1000W/m,). z TEMPERATURE COEFFICIENTS Temperature Coefficient oflsc D [%/K] +0.04 Temperature Coefficient ofVcc [%/Kl -0.27 Temperature Coefficient of PM„ y [%/K] -0.36 Normal Module Operating Temperature NMOT [°C] 43±3 0 m 0 PROPERTIES FOR SYSTEM DESIGN e Maximum System Voltage Vs IV] 1000 Safety Class II o M Maximum Reverse Current Ia [A] 20 Fire Rating C Max.Design Load,Push/Pull [Pa] 3600/2667 Permitted Module Temperature -40°C-+85°C Max.Test Load,Push/Pull [Pa] 5400/4000 on Continuous Duty p 0 a QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION a VIDE Quality Tested,IEC 61215:2016;IEC 61730:2016,Application Class II; Number of Modules per Pallet 32 W This data sheet complies with DIN EN 50380. Number of Pellets per Trailer(24t) 28 p Number of Pellets per 40'HC-Container(26t) 24 DVE C E Pallet Dimensions(L x W x H) 1815 x 1150 x 1190 mm Pallet Weight 683kg Note.Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation o and use of this product. _o Hanwha G CELLS GmbH Sonnenallee 17-21,06766 Bitterfeld-Wolfen,Germany I TEL+49(0)3494 66 99-23444 1 FAX+49(0)3494 66 99-23000 1 EMAIL sales@q-cells.com I WEB www.q-cells.com Engineered in Germany OCELLS NOM: 1.1 COMPLIES WITH NEC 2017 2.)REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 3.1 STICKERS,LABELS,AND PLACKARDS SHALL BE OF SUFFICIENT DURRABIUTN TO WITHSTAND THE ENVIROMENT INVOLVED Tr • a MIAR PV SYSTEM EOUE'PED \/ S To be located on all Lx function boxes NOR RAPID SHUTDOWN _l -�/ and every 10'on[K conduit -- 7 ,• • = SOLAR NEC 690 3l(G) •� NEC 690.561g1111A) DC Junction Box 690 56(C)(3) NEC 690.4(BI Service Disconnect • •• �- 690.56(C)(3) NEC 6 00 13(BI NEC nW 53 futnd e�x SOISYSTEM E0IP wily • • • WrtH RAP D SHUTDOWNY1�0.f'1^"iM10 NEC 690.4(8) NEC 690.13(111 i NEC 690.Sfi([)(1)1A) H System Is eackled Breaker NEC 690.54 NEC 690.53 NEC 705.1218112) NEC 690-54 uC Di�cuni,rit Utlllty Meter Socket gNll b9U 13161 - - NEC 6 0.13( NEC 690.54 or NEC 690.13(8) K r• DC Conduit Main Service Panel Solar Meter Socket Photovoltaic Load Center Inverter(s) Enphase Envoy Box AC Disconnect ITo Combine Inverter•) INSTALLATION OF NEW OAKLAWN AVENUE* ROOF MOUNTED PVSOLAR SYSTEM 'III'T HA y0 s �`O f�B 2025 OAKLAWN AVENUE _� rt ., e: r 1 % Oki SOUTHOLD., NY 11971 `��$ * • ',, ff- �0 095675 ROFESSIota ONO Issued/Revisions � t al ns awET ]z/a/zwl Rl SYSTEM 512E DECREfSE 8/2J/2031 Rl ISSUEDTO TOWNSNIP FOR PERMIT 8/]7/2021 VICINITY MAPSITE NO. DESCRIPTION DATE SCALE: NTS Project Title: ANDREA DAPOLITO;JOSEPH SACCENTE TRINITY ACCT#:2021-06-593770 Project Address: 2025 OAKLAWN AVENUE SOUTHOLD,NY 11971 41.057939,-72.427836 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE DC COMPANY SPECIFICATIONS, kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLTAMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS AS BUILT PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR P V-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE 2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE MCB MAIN CIRCUIT BREAKER DrawingInformation RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MDP MAIN DISTRIBUTION PANEL AP APPENDIX EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MLO MAIN LUG ONLY DRAWING DATE: 8/17/2021MTD MOUNTED DRAWN BY: IG DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN MTD MOUNTING IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. REVISED BY: IMS 3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE N NEUTRAL RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NEC NATIONAL ELECTRICAL CODE UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. NIC NOT IN CONTRACT System Information: COMPONENT AND INVERTER MANUALS ARTICLE 690 8 705. NO# NUMBER PRIOR A OCP OVER CURRENT PROTECTION AC SYSTEM SIZE: lOkW NTS NOT TO SCALE DC SYSTEM SIZE: 11.6kW INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE ABBREVIATIONS P POLE ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL MODULE COUNT: 29 POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AMP AMPERE PB PULL BOX PH O PHASE MODULES USED: HANWHA 400 THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT PVC POLYVINYL CHLORIDE CONDUIT MODULE SPEC#: C.PEAK DUO BLK ML-G1O.a+ - SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AL ALUMINUM 400 4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF AMP.FRAME PWR POWER UTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR QTY QUANTITY #: 9650107553 CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE RGS RIGID GALVANIZED STEEL UTILITY ACCT SOLID NEUTRAL UTILITY METER#: 98347889 ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SN SNSWITCHBOARD SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT (GENERIC TERM OF JSWBD DEAL TYPE: SUNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY,PROVIDE AS TYP TYPICAL 5. FOR SAFETY,IT IS RECOMMENDED THAT 12. FOR THE PROPER MAINTENANCE AND SPECIFIED) U-0 I. UNLESS OTHERWISE INDICATED THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX XF WEATHERPROOF MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT XFMR TRANSFORMER Rev.No. Sheet TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER +72 MOUNT 72 INCHES TO BOTTOM INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER OF ABOVE FINISHED FLOOR OR PV ` , IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE D {� 17 1y �./V 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH 1E I I 4`!j 1 BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING CONVENTIONS OF THE NATIONAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ELECTRICAL CODE. ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING �j A O AOnA WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH " L LL GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL FU FUSE _ 7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: GND GROUND INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER BUILDING DEPT "UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY (CYCLES PER TOWN OF SOUTHOLD 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) Tr i ftayo GENERAL NOTES SOLAR IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A",PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Ailenwood Road 877-786-7283 Wall,New Jersey 07719 www.Trinity-Solar.com NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP NEW PV SOLAR MODULE,TYPICAL -�-�(REFER TO SPEC SHEET FOR DETAILS) (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) I SOLAR MODULE SOLAR MODULE ♦ _ NEW MOUNTING FOOT/ATTACHMENT POINTS,TYPICAL (REFER TO ECOFASTEN"L"FOOT ECOFASTEN RAIL E NGINEERILNS LETTER FOR SPACING y (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) - CID NEW ECOFASTEN RAIL,TYPICAL ^' _ ,`Q� �"0 TO BE MOUNTED PERPINDICULAR TO �j' `C` (Oc STRUCTURE REFER TO ECOFASTEN EXISTING ASPHALT SHINGLES ECOFASTEN FLASHING n \\\ ( (REFER TO ENGINEERS LETTER FOR SPECS) 'REFER TO SPEC SHEET FOR DETAILS) \� 1 SPECIFICATION/DATA SHEET FOR � * A ll 1 DETAILS) /�!2 r+ �" NEW END CLIP,TYPICAL S.S.LAG BOLT APOC SEALANT / h 1 , M (REFER TO ECOFASTEN SPECIFICATION (REFER TO ENGINEERS LETTER FOR SPECS) SOLAR MODULES SHALL NOT TIN W) —♦ —� �♦' I DATA SHEET FOR DETAILS) EXCEED PEAK HEIGHT. Z EXISTING RAFTER ./� Z (REFER TO ENGINEERS LETTER FOR SPECE) ip NEW MID CLIP,TYPICAL �. I(REFER TO ECFASTEN DATA SHEET OOR DETAILSECIFICATION SOA 09 675 OFFSSIpp1P ATTACHMENT&CLIP DETAIL nPV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF 'T SCALE:NOT TO SCALE SCALE:NOT TO SCALE SCALE:NOT TO SCALE ARRAY SCHEDULE Issued/Revisions BACK Al AS BUILT 12/8/2021 Rl SYSTEM 512E DEME 8/27/2021 11 ISSUEDTOTOWNSNIPrORPERMIT 8/17/2021 R9 R10 NO. DESCRIPTION DATE Project Title: ANDREA DAPOLITO;JOSEPH R1 SACCENTE TRINITY ACCT#:2021-06-593770 7DCProject Address: AC D M L" _ 2025 OAKLAWN AVENUE XX - ' C PATH• SOUTHOLD,NY 11971 41.057939,-72.427836 1'-6"C AR PATH F-----7 r F R6 Drawing Title: R2 AS BUILT PV SOLAR SYSTEM R3 LU R5 - r " LE•PATH UDrawing Information _ 1'-6"C2EAR PATH DRAWING DATE: 8/17/2021 _I I DRAWN BY: IG /cp REVISED BY: JMS ROOF1 � R8 Q System Information: ORIENTATION:54 MODULES:12 PITCH: DC SYSTEM SIZE: 11.6kW ROOF 2 AC SYSTEM SIZE: 10kW MODULES:8 PITCH:23 MODULE COUNT: 29 ORIENTATION:234 ROOF 3 p �j MODULES USED: Q EAK DUO BLK ML-G10.a+ MODULES:0 R 400 MODULE PITCH:39' UTILITY COMPANY: PSEG-LI ORIENTATION:324° UTILITY ACCT#: 9650107553 ROOF MODULES:3 NOTES: UTILITY METER#: 98347889 PITCH:27 DEAL TYPE: SUNNOVA ORIENTATION:235 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE FRONT ROOFS WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MODULES:3 2.)ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. PITCH:40 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ORIENTATION:144 Rev. No. Sheet 4.) AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(E) . ROOF 6 5.) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. !/� MODULES:3 6) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. PV L PITCH:26 A 1 ORIENTATION:55 ROOF 7 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE MODULES:0 QTY SPEC# ORIENTATION:324° R� INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE SP INDICATES NEW PV ONLY SUBPANEL T ARRAY SCHEDULE FOR MORE INFORMATION U� INSTALLED OUTSIDE (UTILITY ACCESSIBLE) TO BE INSTALLED 29 HANWHA 400(Q.PEAK DUO BILK ML-G10.a+400) ROOF 8 MODULES:0 INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE10000H-US0SHBNC4 • • PITCH:39' Q ORIENTATION:144° (.4 ) INDICATES EXISTING METER LOCATION ® INDICATE PANELS THAT USE MICRO INVERTERS. pC INDICATES NEW DC DISCONNECT ROOF 9 REFER TO EQUIPMENT SCHEDULE FOR SPECS. MODULES:0 ,�, OTHER OBSTRUCTIONS n Ity PITCH:AT EP LOCATION: INSIDE EXISTINGINDICATES ELECTRICAL PANEL I p I INSTALLED OUTS DEODUCTION METER TO BE SD _ _ _ SOLAR ORIENTATION:324° II II INDICATES EXISTING SERVICE DISCONNECT ROOF 10 MODULES:0 INDICATES NEW INVERTER TO BE PITCH:40' INDICATES NEW FUSED PV DISCONNECT TO BE 2211 Allenwood Road 877 786-7283 ORIENTATION:144° INSTALLED OUTSIDE(UTILITY ACCESSIBLE) ® INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH Wall,New Jersey 07719 www.Trinity-Solar.com A REFER TO EQUIPMENT SCHEDULE FOR SPECS Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH SOLAR MODULES MOUNTED TO ROOF ON 5 ARRAYS /� /,- N EC 2017 29-400W MODULES ADC/1 SOLAR PER EDGE 01 PER MODULE � 4�A EI AO 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB 8"x8" ---------------------------- I y ZOQ-� e ----- ---------- I Z 15TRING Of 15 MODULES IN SERIES-400 Vmax ------------------- TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO JUNCTION INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT 1 STRING OF 14 MODULES IN SERIES-400 Vmax F BOX * :� TEMP=-16'C I _r *2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 10 ce 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED I LLJ ON ASHRAE HIGHEST MONTH 2%DRY BULB Z Z TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO I �� INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= 33'C �pp X95675`, 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN 'rO�Ess(O�P� TEMPERATURES DO NOT EXCEED 47'C IN THE UNITED STATES(PALM SPRINGS,CA IS 44.1°C). FOR LESS THAN 9 Issued/Revisions CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED I SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS (ALL OF UNITED STATES) I Al AS BUILT 12/8/2021 R1 SYSTEM SIZE DECREASE 8/27/2021 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS I SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT I Pi ISSUED TO TOWNSHIP FOR PERMIT 8172021 CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I NO. DESCRIPTION DATE NEC 690.12(A)THROUGH(D) I I 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED I Project Title: TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC I SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) I ANDREA DAPOLITO;JOSEPH SACCENTE 7.)UNGROUNDED ENTIF ED WITH DHE FOLLOWING OU ER FINISH:C CIRCUIT CONDUCTORS BE TRINITY ACCT#:2021-06-593770 POSITIVE CONDUCTORS =RED I NEGATIVE CONDUCTORS=BLACK NEC 210.5(C)(2) Project Address: I 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV EXISTING 240V 10 NOTE: I 2025 OAKLAW N AVENUE WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE10 120/240V ["'€ 200A MAIN BREAKER INTERNAL REVENUE GRADE MONITORING I PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT UTILITY METER 200A BUSBAR CONTAINED WITHIN SOLAR EDGE INVERTER I SOUTHOLD,NY 11971 SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL SOLAR EDGE PN.RWND-3D-240-MB I 41.057939,-72.427836 CONTAIN S 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN<_ 9 CURRENT CARRYING CONDUCTORS. [ Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS a< I OTHERWISE NOTED AS BUILT PV SOLAR SYSTEM 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ^ LOCKABLE 60A DISCONNECT ROOFTOP AND SHALL BE LIMITED TO 12"IF USED FUSED W/60A FUSES INVERTER#1 D OUTDOORS ^ 240V 1 Drawing Information 11.)OVERCURRENT PROTECTION FOR CONDUCTORS �¢¢eNele __- a + DRAWING DATE: 8/17/2021 IG CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE ^ .. I DRAWN G .8/ LOCATED WITHIN 10'OF THE POINT OF CONNECTION NEC ^ I 705.31 e e V ) I REVISED BY: JMS 4jtjL - - - - - - --------------- -UT WHET)TWO SOURCES FEED A ER,PV R,ONE A e e e e e e N � r UTILITY AND THE OTHER AN INVERTER,PV BACKFEED L �WL I System Information: BREAKER(S)SHALL BE LOCATED OPPOSITE FROM UTILITY -------- f I DC SYSTEM SIZE: 11.6kW NEC 705.12(B)(2)(3)(b) I11------J AC SYSTEM SIZE: 10kW EXISTING MAIN BREAKER LOAD CENTER SQUARE D I I 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY INSULATED LINE TAPS INSTALLED ON PN:D222NRB L----------- MODULE COUNT: 29 GENERATION CIRCUITS AND NO UNUSED POSITIONS OR MAIN FEEDERS MODULES USED: HANWHA400 LOADS NEC 705.12(A) Q.PEAK DUO BLK ML-G10.a+ ( ) MODULE SPEC#: 400 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY: PSEGAI A NEMA 311 RATING UTILITY ACCT#: 9650107553 UTILITY METER#: 98347889 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING DEAL TYPE: SUNNOVA [NEC 690.8(8)(1)]:(15.00*1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA400(Q.PEAK DUO BLK ML-G1C.a+400) Rev.No. Sheet AMBIENT TEMP:33`C,TEMP DERATING FACTOR:.96 RACEWAY DERATING=4 CCC:0.80 Imp 10.77 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR (40*.96)0.80=30.72A Vmp 37.13 TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS ` 30.72A'_18.75A,THEREFORE WIRE SIZE IS VALID Voc 45.3 A #6 THWN-2 GEC 70 EXISTING GROUND ROD Al PV VJl TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 11.14 B 1"CONDUIT W/2-#6 THWN-2,1-#10 THWN-2,1-#10 THWN-2 GROUND 42.00A*1.25=52.50A C 1"CONDUIT W/4-#10 THWN-2,1410 THWN-2 GROUND AWG#6,DERATED AMPACITY INVERTER#1-SE1000OH-USOSHBNC4 AMBIENT TEMP:30'C,TEMP DERATING:1.0 D 1"CONDUIT W/4-#10 THWN-2.1-#10 THWN-2 GROUND • • RACEWAY DERATING`-3 CCC:N/A DC AC 75A*1.0=75A Imp 27 Pout 10000 E 1"CONDUIT W/2-#6 THWN-2,1-#30 THWN-2,1-#10 THWN-2 GROUND 75A'_52.50A,THEREFORE AC WIRE SIZE IS VALID Vmp 400 Imax 42 F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY Voc 480 OCPDmin 52.5 tY CALCULATION FOR PV OVERCURRENT PROTECTION G 1"CONDUIT w/2-#6 rHwN-2,1-#6 rEIwN-z,1-#8 THwN-z GROUND SOLAR TOTAL INVERTER CURRENT:42.00A I Isc 30 Vnom 240 42.00A*1.25=52.50A 2211 Allenwood Road S - 83 -->60A OVERCURRENT PROTECTION 15 VALID Wall,New Jersey 07719 www.Trinityty-Solar.colaccom NEW OAKLAWN AVENUE•INSTALLATION OF ROOF MOUNTED PV SOLAR SYSTEMf* 2025 OAKLAWN AVENUE * r ,� ✓�z r � SO UTH O LD NY 11971 , J OA 095675 R�FESS IONP� Issued/Revisions .t 11 ISSUED TO TDWNSHIP TOR PERMIT 8/17/2021 VICINITY MAP SITE NO. DESCRIPTION DATE SCALE: NTS Project Title: ANDREA DAPOLITO;JOSEPH SACCENTE TRINITY ACCT#:2021-06-593770 Project Address: 2025 OAKLAWN AVENUE SOUTHOLD,NY 11971 41.057939,-72.427836 GENERAL NOTES GENERAL NOTES CONTINUED GENERAL NOTES CONTINUED ABBREVIATIONS CONTINUED SHEET INDEX Drawing Title: 1. THE INSTALLATION CONTRACTOR IS 8. THE DC VOLTAGE FROM THE PANELS IS 14. B) CURRENT PREVAILING UTILITY JB JUNCTION BOX PV-1 COVER SHEET W/ SITE INFO & NOTES RESPONSIBLE FOR INSTALLING ALL ALWAYS PRESENT AT THE OC COMPANY SPECIFICATIONS. kCMIL THOUSAND CIRCULAR MILS EQUIPMENT AND FOLLOWING ALL DISCONNECT ENCLOSURE AND THE DC STANDARDS,AND REQUIREMENTS kVA KILO-VOLT AMPERE PV-2 ROOF PLAN W/ MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM DIRECTIONS AND INSTRUCTIONS TERMINALS OF THE INVERTER DURING 15 THIS SET OF PLANS HAVE BEEN kW KILO-WATT CONTAINED IN THE DRAWING PACKAGE AND DAYLIGHT HOURS.ALL PERSONS PREPARED FOR THE PURPOSE OF kWH KILO-WATT HOUR PV-3 ELECTRICAL 3 LINE DIAGRAM INFORMATION RECEIVED FROM TRINITY. WORKING ON OR INVOLVED WITH THE MUNICIPAL AND AGENCY REVIEW AND L LINE MCB MA IN CIRCUIT BREAKER 2. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM ARE WARNED APPROVAL.ONCE APPROVED,THE MDP MAN DISTRIBUTION PANEL AP APPENDIX DrawingInformation RESPONSIBLE FOR INSTALLING ALL THAT THE SOLAR MODULES ARE INSTALLATION CONTRACTOR IS MLO MAIN LUG ONLY DRAWING DATE: 8/17/2021 EQUIPMENT AND FOLLOWING ALL ENERGIZED WHENEVER THEY ARE RESPONSIBLE FOR INSTALLING ALL MTD MOUNTED DIRECTIONS AND INSTRUCTION CONTAINED EXPOSED TO LIGHT. SYSTEM COMPONENTS AS DESCRIBED IN DRAWN BY: IG MTG MOUNTING IN THE COMPLETE MANUAL. 9. ALL PORTIONS OF THIS SOLAR THE DRAWING PACKAGE. N NEUTRAL REVISED BY: 3. THE INSTALLATION CONTRACTOR IS PHOTOVOLTAIC SYSTEM SHALL BE 16 ALL INFORMATION SHOWN MUST BE NEC NATIONAL ELECTRICAL CODE RESPONSIBLE FOR READING AND MARKED CLEARLY IN ACCORDANCE WITH CERTIFIED PRIOR TO USE FOR NIC NOT IN CONTRACT UNDERSTANDING ALL DRAWINGS, THE NATIONAL ELECTRICAL CODE CONSTRUCTION ACTIVITIES. NO# NUMBER System Information: COMPONENT AND INVERTER MANUALS ARTICLE 690 8 705. NTS NOT TO SCALE DC SYSTEM SIZE: 10.88kW PRIOR TO INSTALLATION.THE INSTALLATION 10. PRIOR TO THE INSTALLATION OF THIS OCP OVER CURRENT PROTECTION CONTRACTOR IS ALSO REQUIRED TO HAVE PHOTOVOLTAIC SYSTEM,THE ABBREVIATIONS P POLE AC SYSTEM SIZE: 10kW ALL COMPONENT SWITCHES IN THE OFF INSTALLATION CONTRACTOR SHALL PB PULL BOX MODULE COUNT: 32 POSITION AND FUSES REMOVED PRIOR TO ATTEND A PRE-INSTALLTION MEETING AMP AMPERE PH 0 PHASE 340 THE INSTALLATION OF ALL FUSE BEARING FOR THE REVIEW OF THE INSTALLATION AC ALTERNATING CURRENT MODULES USED: HANWHA PVC POLY-VINYL CHLORIDE CONDUIT MODULE SPEC p: O.PEAK DUOO BLK-G6+340 SYSTEM COMPONENTS. PROCEDURES,SCHEDULES,SAFETY AND AL ALUMINUM PWR POWER 4. ONCE THE PHOTOVOLTAIC MODULES ARE COORDINATION. AF AMP.FRAME UTILITY COMPANY: PSEG-LI MOUNTED,THE INSTALLATION 11. PRIOR TO THE SYSTEM START UP THE AFF ABOVE FINISHED FLOOR QTY QUANTITY RGS RIGID GALVANIZED STEEL UTILITY ACCT It: 9650107553 CONTRACTOR SHOULD HAVE A MINIMUM OF INSTALLATION CONTRACTOR SHALL AFG ABOVE FINISHED GRADE. ONE ELECTRICIAN WHO HAS ATTENDED A ASSIST IN PERFORMING ALL INITIAL AWG AMERICAN WIRE GAUGE SOLID NEUTRAL UTILITY METER#: SUNNO89 JS SOLAR PHOTOVOLTAIC INSTALLATION HARDWARE CHECKS AND DC WIRING C CONDUIT (GENERIC TERM OF WBD SWITCHBOARD DEAL TYPE: UNNOVA COURSE ON SITE. CONDUCTIVITY CHECKS. RACEWAY,PROVIDE AS TYP TYPICAL 5. FOR SAFETY,IT O RECOMMENDED THAT 12, FOR THE PROPER MAINTENANCE AND SPECIFIED) WPI UNLESS WEATHERPROOF ISE INDICATED nD �h ,.,� THE INSTALLATION CREW ALWAYS HAVE A ISOLATION OF THE INVERTERS REFER TO CB COMBINER BOX XFMR TRANSFORMER IrLC�/`vim" V MINIMUM OF TWO PERSONS WORKING THE ISOLATION PROCEDURES IN THE CKT CIRCUIT +72 MOUNT 72 INCHES TO BOTTOM DD Rev.No. Sheet TOGETHER AND THAT EACH OF THE OPERATION MANUAL. CT CURRENT TRANSFORMER OF ABOVE FINISHED FLOOR OR INSTALLATION CREW MEMBERS BE TRAINED 13. THE LOCATION OF PROPOSED ELECTRIC CU COPPER ^ w �` , IN FIRST AID AND CPR. AND TELEPHONE UTILITIES ARE SUBJECT DC DIRECT CURRENT GRADE ru 1 V 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO TO FINAL APPROVAL OF THE DISC DISCONNECT SWITCH S E P 1 5 2021 BE INSTALLED FOLLOWING THE APPROPRIATE UTILITY COMPANIES AND DWG DRAWING CONVENTIONS OF THE NATIONAL OWNERS. EC ELECTRICAL SYSTEM INSTALLER ELECTRICAL CODE. ANY LOCAL CODE 14. ALL MATERIALS,WORKMANSHIP AND EMT ELECTRICAL METALLIC TUBING WHICH MAY SUPERSEDE THE NEC SHALL CONSTRUCTION FOR THE SITE FS FUSIBLE SWITCH GOVERN. IMPROVEMENTS SHOWN HEREIN SHALL FU FUSE BUILDING DEPT. 7. ALL SYSTEM COMPONENTS TO BE BE IN ACCORDANCE WITH: GND GROUND INSTALLED WITH THIS SYSTEM ARE TO BE A) CURRENT PREVAILING MUNICIPAL GFI GROUND FAULT INTERRUPTER TOWN OF SOUTHOLD "UL"LISTED.ALL EQUIPMENT WILL BE NEMA AND/OR COUNTY SPECIFICATIONS, HZ FREQUENCY (CYCLES PER 3R OUTDOOR RATED UNLESS INDOORS. STANDARDS AND REQUIREMENTS SECOND) TaSOLAR GENERALNOTES S O L A R IF ISSUED DRAWING IS MARKED WITH A REVISION CHARACTER OTHER THAN"A',PLEASE BE ADVISED THAT FINAL EQUIPMENT AND/OR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITY OF EQUIPMENT. 2211 Allenwood Road 877-786-7283 Wall,New Jersey 07719 www.Trinity-Solar.com NOTES:'REFER TO MODULE SPECS FOR MODULE DIMENSIONS 'DEPICTED MODULES MAY BE PORTRAIT OR LANDSCAPE ECOFASTEN CLAMP NEW PV SOLAR MODULE,TYPICAL 'REFER TO SPEC SHEET FOR DETAILS) (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) SOLAR MODULE SOLAR MODULE ♦ ♦ NEW MOUNTING FOOT/ATTACHMENT POINTS,TYPICAL (REFER TO ECOFASTEN"L"FOOT ECOFASTEN RAIL ENGINEERING LETTER FOR SPACING (REFER TO SPEC SHEET FOR DETAILS) (REFER TO SPEC SHEET FOR DETAILS) AND DETAILS) D7AL nO F N E NEW ECOFASTEN RAIL,TYPICAL x — Gu kV To BE MOUNTED PERPINDICULAR TO EXISTING ASPHALT SHINGLES ECOFASTEN FLASHING —n� Q� \CHAEz STRUCTURE(REFER TO ECOFASTEN e O SPECIFICATION/DATA SHEET FOR (REFER TO ENGINEERS LETTER FOR SPECS) (REFER TO SPEC SHEET FOR DETAILS) r G O DETAILS) JA _J ✓ NEW END CLIP,TYPICAL S.S.LAG BOLT- -APOC SEALANT / SZZ �♦ _ • (REFER TO ECOFASTEN SPECIFICATION (REFER TO ENGINEERS LETTER FOR SPECS) SOLAR MODULES SHALL NOT I I DATA SHEET FOR DETAILS) EXCEED PEAK HEIGHT. C� EXISTING RAFTER � (REFER TO ENGINEERS LETTER FOR SPECS) 171 L NEW MID CLIP,TYPICAL U (REFER TO ECOFASTEN SPECIFICATION I DATA SHEET FOR DETAILS) 0 G ✓ ,° ATTACHMENT&CLIP DETAIL PV MODULE ATTACHMENT ON ASPHALT SHINGLE ROOF HEIGHT FROM GROUND LEVEL TO PEAK OF ROOF SCALE:NOT TO SCAt F SCALE:NOT TO SCALE SCALE:NOT TO SCALECE S I O 4l- ARRAY SCHEDULE Issued evisions BACK PI ISSUED TO TOWNSHIP FOR PERMIT 8/17/2021 R9 R1O NO. DESCRIPTION DATE Project Title: ANDREA DAPOLITO;JOSEPH LR1 SACCENTE TRINITY ACCT#:2021-06-593770 DC Project Address: AcFU1 rm' 3- 2 SOUTTHO D,Y 11971 AVENUE025 OAKLAWN 1'- "CLEAR PATH 41.057939,-72.427836 1`-6"CLEAR PATH � / ��' R6 Drawing Title: am 4 a R2 LU _ -_ PROPOSED PV SOLAR SYSTEM Q Q R3 w RrJ 1'-6"CLEAR P DrawingInformation U U I V-6"CLEAR PAT/ DRAWINGDATE: 18/17/2021 to Zc r DRAWN BY: IG m REVISED BY: ROOF 1 J System Information: MODULES:32 j R7 R8 PIa ORIENTATION:54 DC SYSTEM SIZE: 10.88k W ROOF 2 J AC SYSTEM SIZE: 10kW MODULES:8 PITCH:26 MODULE COUNT: 32 ORIENTATION:234 O � MODULES USED: HANWHA 340 ROOF DULES:0 4 MODULE SPEC N: Q.PEAK DUO BLK-G6+340 PITCH:39' ORIENTATION:324' UTILITY COMPANY: PSEG-U UTILITY ACCT IJ: 9650107553 ROOF 4 UTILITY METER#: 98347889 MODULES:5 NOTES: PITCH:25 DEALTYPE: SUNNOVA ORIENTATION:235 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE F RONT ROOF 5 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MODULES:4 2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. PITCH:39 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION ORIENTATION:144 4.) AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(S) NEC 690.13(E) Rev No. Sheet ROOF 6 5.) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. MODULES:3 6.) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. PITCH:25 _ ORIENTATION:55 PV 2 SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE ROOF7 MODULES:0 QTY SPEC# ORIEN ATION:324° ( INDICATES ROOF DESIGNATION.REFER TO INDICATES NEW UNFUSED PV DISCONNECT TO BE SP INDICATES NEW PV ONLY SUBPANEL ARRAY SCHEDULE FOR MORE INFORMATION U� INSTALLED OUTSIDE (UTILITY ACCESSIBLE) TO BE INSTALLED 32 HANWHA 340(Q.PEAK DUO BU(-G6+340) ROOF8 MODULES:0INDICATES NEW PV SOLAR MODULE.RED MODULES 1 SE10000H-US0OOBNC4 PITCH:39' ORIENTATION:144° INDICATES EXISTING METER LOCATION INDICATE PANELS THAT USE MICRO INVERTERS. DC INDICATES NEW DC DISCONNECT ROOF9 — - IREFER TOEQUIPMENT SCHEDULE FOR SPECS. - OTHER OBSTRUCTIONS MODULES:0 Tr PITCH:40'AT INDICATES LOCATION:INSIDE GELECTRICAL PANEL INDICATES( p I INSTALLED OUTS DEODUCTION METER TO BE SD SOLAR ` ORIENTATION:324° EP 11 " 11 INDICATES EXISTING SERVICE DISCONNECT J O L A 4R ROOF10 __ ----- MODULES:0 INDICATES NEW INVERTER TO BE PITCH:40' INDICATES NEW FUSED PV DISCONNECT TO BE ® 2211 Allenwood Road 877-786-7283 ORIENTATION:144° ED INSTALLED OUTSIDE(UTILITY ACCESSIBLE INSTALLED OUTSIDE. TS INDICATES EXISTING TRANSFER SWITCH A REFER TO EQUIPMENT SCHEDULE FOR SPECS Wall,New Jersey 07719 www.Trinity-Solar.com Engineer/License Holder: ARRAY CIRCUIT WIRING NOTES 1. LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH SOLAR MODULES MOUNTED TO ROOF ON 5 ARRAYS C tE1 NEC 2017 32-340W MODULES W/1 SOLAR EDGE P401 PER MODULE 2.)LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON 15 ADC MAX PER STRING Al \CHAE(6 j00 ASHRAE MINIMUM MEAN EXTREME DRY BULB 8"x8" --------------------------- ---------- 2 STRINGS OF 16 MODULES IN SERIES-400 Vmax --- JUNCTION 01/ TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO --- --'---------------- 1 INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT F BOX I * A G TEMP=-16°C I Z *2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 I _r 3.)HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED [ (7 w ON ASHRAE HIGHEST MONTH 2%DRY BULB I T't 4a TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO [ Z Z INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= I 33°C �9675 ��C9 4.)2005 ASHRAE FUNDAMENTALS 2%DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED I FfSSIOTA STATES(PALM SPRINGS,CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED. Issued/Revisions SUNLIT CONDUIT AT LEAST 0.5"ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) I 5.)PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT ISSUED 8/17/2021CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH I NEC 690.12(A)THROUGH(D) NO. DESCRIPTION DATE 6.)PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED I Project Title: TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41(A)(4) I ANDREA DAPOLITO;JOSEPH 7.)UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE I SACCENTE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: TRINITY ACCT#:2021-06-593770 POSITIVE CONDUCTORS =RED NEGATIVE CONDUCTORS=BLACK NEC230.5(C)(2) Project Address: 8.)ARRAY AND SUB ARRAY CONDUCTORS SHALL BE#10 PV EXISTING 240V 10 NOTE' I WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE 10 120/240V INTERNAL REVENUE GRADE MONITORING I 2025 OAKLAW N AVENUE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT UTILITY METER 200A MAIN BREAKER CONTAINED WITHIN SOLAR EDGE INVERTER I SOUTHOLD, NY 11971 SUNLIGHT.SUB ARRAY CONDUIT LONGER THAN 24"SHALL 200A BUSBAR SOLAR EDGE PN.RWND-3D-240-MB I 41.057939,-72.427836 CONTAIN15 20 CURRENT CARYING CONDUCTORS AND I WHERE EXPOSED TO DIRECT SUNLIGHT SHALL I CONTAIN<_9 CURRENT CARRYING CONDUCTORS. Drawing Title: 9.)ALL WIRE LENGTHS SHALL BE LESS THAN 100'UNLESS ^F I OTHERWISE NOTED I PROPOSED PV SOLAR SYSTEM 10.)FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON LOCKABLE 60A DISCONNECT ROOFTOP AND SHALL BE LIMITED TO 12"IF USED FUSED W/60A FUSES OUTDOORS 240V 1 INVERTER Drawin Information 11.)OVERCURRENT PROTECTION FOR CONDUCTORS ¢CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE DRAWING DATE: 8/17/2021 LOCATED WITHIN 10'OF THE POINT OF CONNECTION NECK_ DRAWN BY: IG 705.31 .... _-- . �� REVISED BY: 12.)WHERE TWO SOURCES FEED A BUSSBAR,ONE A 0- ;0 UTILITY AND THE OTHER AN INVERTER,PV BACKFEED Ll L2 Ne e r` S stem Information: BREAKER(S)SHALLBELOCATEDOPPOSITEFROMUTILITYeeeeem - - - - - - - --------------- -�----- -----J IDC SYSTEM SIZE: 10.88kW NEC 705.12(8)(2)(3)(b) EXISTING MAIN BREAKER LOAD CENTER SQUARED - �----_ _ AC SYSTEM SIZE: lOkW 13.)ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY INSULATED LINE TAPS INSTALLED ON PN:D222NRB -----_- --J MODULE COUNT: 32 GENERATION CIRCUITS AND NO UNUSED POSITIONS OR MAIN FEEDERS NEC 705.12(A) MODULES HANWHA 340 LOADS MODULE SPEC#: Q.PEAK DUO BLK-G6+340 14.)ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE UTILITY COMPANY: PSEG-LI A NEMA 3111 RATING UTILITY ACCs#: 9650107553 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS UTILITY METER#: 98347889 REQUIRED CONDUCTOR AMPACITY PER STRING DEAL TYPE: SUNNOVA [NEC 690.8(6)(1)]:(15.00'1.25)1=18.75A PV MODULE SPECIFICATIONS AWG#10,DERATED AMPACITY HANWHA 340(Q.PEAK DUO BLK-G6+340) AMBIENT TEMP:33°C,TEMP DERATING FACTOR:.96 Rev. NO. Sheet RACEWAY DERATING=4 CCC:0.80 Imp 10.2 NOTE:CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR (40°.96)0.80=30.72A - Vmp 33.94 TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS 30.72A'-18.75A,THEREFORE WIRE SIZE 15 VALID Voc 40.66 A #6 THWN-2 GEC TO EXISTING GROUND ROD P1 PV 3 TOTAL AC REQUIRED CONDUCTOR AMPACITY Isc 10.52 B 1"CONDUIT W/246 THWN-2,1410 THWN-2,1410 THWN-2 GROUND 42.00A'1.25=52.50A C 1"CONDUIT W/4-#10 THWN-2,1410 THWN-2 GROUND AWG#6,DERATED AMPACITY INVERTER#1-SE10000H-USOOOBNC4 AMBIENT TEMP:30°C,TEMP DERATING:1.0 DC AC D 1"CONDUIT W/4-#lOTHWN-2,1-#10 THWN-2 GROUND Tri • RACEWAY DERATING`_3 CCC:N/A 75A'1.0=75A mp 27 Pout 10000 E 1"CONDUIT W/2-#6 THWN-2,1-#10THWN-2,1-#10THWN-2 GROUND 75A'-52.50A,THEREFORE AC WIRE SIZE IS VALID Vmp 400 Imax 42 -4 Voc 4AC OCPDmin 52.5 F #10 PV WIRE(FREE AIR)W/#6 BARE COPPER BOND TO ARRAY C CALCULATION FOR PV OVERCURRENT PROTECTION SOLAR TOTAL INVERTER CURRENT:42.00A Isc 30 Vnom 240 G 1"CONDUIT W/2-t/6 THWN-2.1-#6 THWN-2,1-#6 THWN-2 GROUND 42.00A"1.25=52.5OA 2211 Allenwood Road 877-786-7283 -->60A OVERCURRENT PROTECTION 15 VALID Wall,New Jersey 07719 www.Trinity-Solar.com