Loading...
HomeMy WebLinkAbout46629-Z �o�QS�fFU Town of Southold 2/6/2022 0 P.O.Box 1179 2.� 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42765 Date: 2/6/2022 THIS CERTIFIES that the building RESIDENTIAL ALTERATION Location of Property: 870 Sound View Rd, Orient SCTM#: 473889 See/Block/Lot: 15.-3-27 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/19/2021 pursuant to which Building Permit No. 46629 dated 7/28/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alterations to existing single-family dwelling as applied for. The certificate is issued to Needham,Catherine&Donahue,Timothy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46629 1/31/2022 PLUMBERS CERTIFICATION DATED 2/4/2022 Ol 11Bing&H ting 0 rit0 gnature SUF TOWN OF SOUTHOLD ��o� COGy t BUILDING DEPARTMENT C* x ' TOWN CLERK'S OFFICE o . � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46629 Date: 7/28/2021 Permission is hereby granted to: Selwyn Michael Irry Trust 870 Sound View Rd Orient, NY 11957 To: construct interior alterations to existing single-family dwelling as applied for. At premises located at: 870 Sound View Rd SCTM # 473889 Sec/Block/Lot# 15.-3-27 Pursuant to application dated 7/19/2021 and approved by the Building Inspector. To expire on 1/2712023. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $272.00 CO-ALTERATION TO DWELLING $50.00 Total: $322.00 Building Inspector pF SOUryol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 ►. �e sean.deviin(&-town.southold.ny.us Southold,NY 11971-0959 QIyCOU�S�,�a BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Catherine Needham Address: 870 Sound View Rd city:Orient st: NY zip: 11957 Building Permit#: 46629 section: 15 Block: 3 Lot: 27 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Promaster Electric License No: 59226ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor X Hot Tub Addition Survey Attic X Garage INVENTORY Service 1 ph Heat Duplec Recpt 21 Ceiling Fixtures 2 Bath Exhaust Fan 3 Service 3 ph Hot Water GFCI Recpt 4 Wall Fixtures 6 Smoke Detectors 4 Main Panel A/C Condenser Single Recpt Recessed Fixtures 35 CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan 2 Combo Smoke/CO 3 Transformer UC Lights Dryer Recpt 30A Emergency Fixtures Time Clocks Disconnect Switches 35 4'LED Exit Fixtures Pump Other Equipment: Fridge, Gas Oven, DW, Micro, Hood, W/D, LED Mirror, Warming Drawer Notes: Added Lights Everywhere and Added Three Bathrooms Inspector Signature: l Date: January 31, 2022 S.Devlin-Cert Electrical Compliance Form Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 BUILDING DEPARTMENT n(/ TOWN OF SOUTHOLD ® I5 1Ui V FEB n 4 777 E ID BUILDING DEPT. TOWN'Or SOUTHOLD CERTIFICATI-.ON Date: Zj 12 0 2 L Building Permit No. �E a Owner: ilea a print) Plumber: (zA ?cl (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. { i s Signature) Sworn to before me this 4 ' day of Feb;-Lu y 20 22 GINA A.LOCKS ��— NOTARY PUBLIC,STATE Olt NEW YORK E Registration No.OIL06057960 Qualified in Suffolk County _ Commission Expires Apr.30,20 2 3 Notary Public, S--cffas►< Gouiity° i �sl i 4 SOUlyo6 * TOWN OF SOUTHOLD BUILDING DEPT. ��`ycouFm '� 765-1802 _.IN;SPEO ON [ ] FOUNDATION 1ST [ ROUGH PLBG. [ OUNDATION 2ND Y [; ] INSULATION/CAULKING ] [ FRAMING/STRAPPING [ ] FINAL ] FIREPLACE & CHIMNEY [` ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O L MARKS: r t 0 DATE t1)0)-4 INSPECTO *fF SU(/r,�0 # TOWN OF SOUTHOLD BUILDING DEPT. °�ycourm,� 765-1802 INSPEC ION [ ] F NDATION 1 ST [ ROUGH PLBG. [ ] -OUNDATI,ON '2ND [ ] ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: Oat/ �W -lvc( Q � T Q DATE Z ZpZ2 INSPECTOR �a0f 50UTyo o l TOWN-OF SOUTHOLD BUILDING DEPT. 765-1802 : 1 NSPECTION [ ] FOUNDATION 1ST [ ] , ROUGH PLBG: [ ] FOUNDATION 2ND [ ] -INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY" [ ] FIRE SAFETYINSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION- [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: DATE 1 -5/ INSPECTOR -��- FOUNDATION11ST) • A • e A — Iry �'�° �a • A rl� s o ® Libi —t INSULATION, k Sam A • A A ® Al f ®" __ �I 1 W - ,' o�°SufFot,r"oG TOWN OF SOUTHOLD-BUILDING DEPARTMENT �� y2 y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtowm.gov Date Received APPLICATION FOR BUILDING PERMIT r Office Use Only DD �C�PERMIT NO. Building Inspector: JUL 19 2021 Applications and forms must be filled out in their entirety. Incomplete BUILDT NG DEPT. applications will not be accepted. Where the Applicant is not the owner,an TOINTNT OF SOUTHOLD Owner's Authorization form(Page 2),shall be completed. Date: .J Z OWNER(S)OF PROPERTY: 5 C ► ``I�C 1 01 Name: CA __ — _- �. IiI _ .. . SCTM#1000- I Project Address: ©g —� R-Z-a-A �-- �,, _ m_ ._ 1 t -1__. Phone#: � 4 Email: _ 3-- _ _ Mailing Address: -z" -._.------____-_ _' _tea CONTACT PERSON: Name: " Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION: -Name--- - -�_��--�_C/'_�_l��-rI J------------------- - ----------------- __------- --------- _-- ----- ------- Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: c Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION *New Structure MAddition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $ A ac Will the lot be re-graded? []Yes NJNo Will excess fill be removed from premises? ❑Yes rRNo 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ONO IF YES, PROVIDE A COPY. El Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues.as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are .punishable as a Class A misdemeanor pursuant to Section 210.45.of the New York State Penal Law. Application Submitted By(print name): lim Authorized Agent Downer Signature of Applicant: Date: STATE OF NEW YORK) SS. COUNTY OF ) I JQC a u f+ being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing cont ct) above named, (S)he is the (Contractor, gent, Corporate Officer, etc.) of said owner or owners, and is duly aut o o perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief, and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this L9day of , 20 Notary Public TRACEY L. DWYER NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION NO.01 OW63069oo QUALIFIED IN SUFFOLK COUNTY (Where the applicant is not the owner) COMMISSION EXPIRES JUNE 30,2nQIR I, 21f'l l� t, 6co residing at 'S�`�,ndu do hereby authorize,—P(k r; l P),6ag to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date C C�la l�Q� �U w� Print Owner's Name 2 Building Debartment Application i AUTHORIZATION (Where the Applicant is not the Owner) esiding at (Print property owner's name) (Mailing Address) do hereby authorize T.6�( �'� (Agent) to apply on my;behalf to the Southold Building Department. ` (Owner's Signature) (Date) (Print Owner's Name) jl�-D fl -)I BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD CD "� Town Fla I Annex- 54375 Main Road - PO Box 1179 • JAN 2 7 2022 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ~rogxr(csoutholdtownny.gov seand(cDsoutholdtownny.gov TOIP a c,- APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: y £ Electrician's Name: License No.: ,{ Elec. email: 2�£ Elec. Phone No: request an email copy of Certificate of Compliance Elec. Address.: Z JOB SITE INFORMATION (All Information Required) Name: � mh&n, Address aiD nIZC f�±i Cross Street: Phone No.: Bldg.Permit#: eY'j'G°,2 0 email: Tax Map District: 1000 Section: S Block: Lot: BRIEF C / � DES,,CRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# F]New Service[:]Fire Reconnect❑Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? 0 Y DN Additional Information: PAYMENT DUE WITH APPLICATION _----------_._ _-------------------------------------__----------__ ---- --��`�,-off._--------.------- PERMIT# Address: Switches Outlets N` GFI's E �. Surface. Sconces HHs . � .. UC Lts HW Fans F.r�dge .. Exhaust Oven W/D ,�iT� Smokes 1 DW Mini �..r... .1,1A.:_._. Carbon 41 11 ..l 'G:enerator Coolcto Trans€er Com �1. DIP AC AH _... Hood Service Amps Have Used Special Comments: SOUND VIEW ROAD R - 498. 16 '98 . 16 ❑ EDGE OF PA ° ❑ VEMENT 104 • 3 4 BR 1 C K APRON •0 •B ❑ In 625.00, AREA OF DETAIL G BATHROOM DEMOLISH EXISTING BATHROOM BRICK H TWO AND REPLACE WITH TWO O to BATHROOMS WALKWAY SLATE CO I ARCHITECTURE r-- M STEPS . N I DWGS 4+5/A-100 PLL C 4'DEER 1 4 FENCE m OPEN wooD a % I 411, , D AS NOTED DANIEL K O H S, R.A. WOOD STEPS WOOD T �P v 19( PORCH DECK � x W i 15 TIBBITS LANE 42.7' P I DATEB.P.# PORT WASHINGTON FEE: 10 _ �v�� m I BY: NEW YORK 11050 6 14 T. (6 41.x' I 90O 765-1802 BUILDING D4 PARTMENT AT PM FOR THE 11.5' 14.0' 13.9' DRAIN Q I FOLLOWING INSPECTIONS: LOT 25 2-STORY j GARAGE y GRATE I I 6 4 6 - 8 7 2 - 0 2 8 6 O I 1. FOUNDATION - TWO REQUIRED - 516 - 883 - 9433 HOUSE I m S o LOT 27 I I 2. ROUGH FOR u FRAMRED INGCRETE& PLUMBING 'I? No. 870 ------ �y�'F19�\ -� E-1-1 3. INSULATION DKOHS _� 9119i'1'i Q I I 4. FINAL - CONSTRUCTION MUST ❑ -------------- ti Up DN DN I SYNTHESISARCHITECTURE.NET 4'ALUMINUM < �' '� I I BE COMPLETE FOR C.O. FENCE ¢� � ALL CONSTRUCTION SHALL MEET T 1-STORY W/GATE a Z STEPS W e I I I I REQUIREMENTS OF THE CODES OF NE' SLATE RELOCATE WASHER AND 16.1' ELECTRIC DRYER I I I I YORK STATE. NOT RESPONSIBLE FCS W I I DESIGN OR CONSTRUCTION ERROR FE L6 26.6' N � I II I 0.5'E N a Q z W h-1--I I I I COMPLY WITH ALL COD S OF OCCUPANCY 0 W WOOD PATIO DECK ¢`-� FE �-t� 15 9' 4'DEER _QI w Q o.9'E I I I I NEW YORK STATE & TOW CODES OCCU I I cn o= ! 4�(C"Z FENCE �i I LOAD AREA FOR HEADER I AS REQUIRED AND CONDI ONS Or USE IS UNLA • _ _ w 10.7 2 6.7' 8 WOOD FE�E 6.0„ �——J 6'X 8''=00#IFT 4,800# LOAD AREA FOR HEADER `' ' I f. /`t ,30 5 �---� LL. WOOD STEPS I I I (65DL+15LL) 11'X 14'=154 X 100=15,400#/11'=1,400#/FT J W�� 0"� F ' w FE U L_J I I (85DL+15LL) SO L I t IG BOARS ! r FE FE 2 OF OCCUIPA' --- - - _ -- i SOtRitCu�GNTR TEES . 0.9'w CD LU u► ❑ / 11'o,. ° ———i 1r o• uL ` I CD 0 1 O HEADER: PLUf'11BER CERTIFt WEST ERASER LVL ATPO1\P LLIO 1/314"WIDE X 7.25"=924# 0 w O O O 0 L/240 DEFLECTION AND I I— _ — —— — _ �'`•�' O��d LEAD CONTENT BFFQRE' L,OT 26 0 O ❑ ° 2.4"OF BEARING. L. ——— _ —— ———— —————° ALL.PLUMBING WASTE CERTIFICATE OF QCCUPANC i w T�IK,�f:$ t=O.RE.COVERING SOLDER USED IN WA7 7 0 w z � 3 w &WATER LINES NEED O SUPPLY SYSTEM DOUBLE HEADER: Z co NLARGE OPENING FOR ENLARGE OPENING FOR WEST FRASER LVL CAN�NOT 0 ❑ EXCEED 2/10 OF 1% LEAD. C) SURVEY OF NEW 5'-9"RELOCATED NEW 11'-0"DOUBLE SLIDING ❑ U240D DLECTIO A D25# FE ❑ LI240 DEFLECTION AND 3.4'OF BEARING ° UTILITY DOUBLE SLIDING DOORS WITH SIDELIGHTS. NAIL TOGETHER PER MFG.SPECIFICATwr,s O w"oZi POLE 0.5 N �..e�.`�mCA 1.5'E LOT 2 6 DOORS WITH SIDELIGHTS. NEW HEADER AND POSTS TO EDGED 3.5"NAILS 12"OC IN 3 ROWS.? s 1 REOU1 z L`o O H E D G E 0.6'N NEW HEADER AND POSTS ` — — = MAP OF ❑ ° ❑ ❑ ❑ ° ❑ ❑ ❑ ❑ ❑ — — — 6'wo0 ORIENT BY THE SEA ° FE 4 ' DEER FEIN CE OVERHEAD FE FENCE 1.8'S 2.s's WIRES FILED ON NOVEMBER 21 , 195 /-7 DRAWING HISTORY: S89°30' 00" W 73. 16 ' AS MAP No. 2777 ° LOT �5 STUA TE ❑ ❑ "Map of orient-by-the-sea, Section 2" ORIENT, TOWN OF S O U TH O L D Map No, 3444 SUFFOLK COUNTY, NEW YORK Filed October 26, 1961 TAX No. 1000-01500-0300-027000 SCALE 1"=20' APRIL 10, 2021 SURVEY AREA q• = 13,396.62 s ft. SCOPE OF WORK - KEY PLANS - EXISTING CONDITIONS - FIRST FLOOR 1 NTs �NTS n SCOPE OF WORK- KEY PLANS - EXISTING CONDITIONS - SECOND FLOOR 0.308 ac. NTS NEW 2X4 PARTITION W/5/8"GYP. BD.TAPE AND PAINT. WET SIDE TO BE 112"CEMENT BOARD,TAPED JOINTS, FULL HT.TILE. /, r 10 0 REMOVE ALL FIXTURES AND FINISHES TO THE STUDS. DRY SIDE GETS WOOD BASEBD.TO MATCH ADJACENT.TYPICAL. REMOVE NON-LOAD BEARING PARTITION AS NECESSARY 4" FOR THE NEW WORK 2'-9" V-10" 4'-9" 12'-0" 10'-11" 6-6"- SALVAGE OORS FOR-REUSE T-s" A 5'-7^ LO 4'-6" 1 5 10 15 rr--- - FAN A"CFAN BEDROOM I I I I GHT BEDROOM BEDROOM FAN N cn BEDROOM c IGHT BEDROOM � I SH WEIR I I \ , I I I I o FAN I I \ I I I I o S W N $ WIF N L —_ _ G1iTJ I e� \ I I I I IGHT pIGHT LAG \ U- 1CL , — GFI 1 GF GFI NEEDHAM/DONOHUE FRAMINGRESIDENCE I I I \\ GSI BATH I 16'-2" BATH BATH —1 , ATH ❑ PROJECT LO❑ O O CATION ❑ GkI 4'-51/2" GFI GF ❑ I I ❑ �, - 870 SOUND VIEW ROAD ORIENT, NY CLOSET CL - � II 2'-6" 1'-7" 2'-6" 1" '_0" EXISTING WASTE STACK 2'-6" — 4'-1 5'-0" 1.9.. EXISTING TOILET ROUGH TO REMAIN REPLACE FIXTURE WITH NEW TOILET CONSTRUCTION PLANS NOTES: NOTES: SHUT OFF VAVLES FLOORS TO BE 314"EXT.GRADE PLYWD,W/APPLIED 1. FAN LIGHT UNIT TO BE ENERGY STAR RATED. FOR SECOND FLOOR WATERPROOF MEMBRANE TO WALLS AND UP 4".THINSET 1. FAN LIGHT UNIT TO BE ENERGY STAR RATED. 2. ALL LIGHTS TO BE LED 2700K TYPE AND PORCELAIN TILE WITH GROUT TO MATCH TILE. 2, ALL LIGHTS TO BE LED 2700K TYPE 3. SWITCHES ARE 48"AFF, OUTLETS ARE 16"AFF, 3. SWITCHES ARE 48"AFF,OUTLETS ARE 16"AFF, SEAL AND SIGNATURE: DATE: 7-14-21 4. GFI LOCATIONS PER ELEVATIONS OR TO BE DETERMINED IN THE FIELD. ALL PLUMBING FIXTURES AND FAUCETS TO BE LOW FLOW 4. GFI LOCATIONS PER ELEVATIONS OR TO BE DETERMINED IN THE FIELD �5�� ED ARCy�r PROD No: 22106 5. LOAD SHOWN IS LESS THAN CURRENTLY EXISTS IN THE SPACE. NYS CODE COMPLIANT. ALL NEW DRAIN PIPING TO BE PVC 5. LOAD SHOWN IS LESS THAN CURRENTLY EXISTS IN THE SPACE. �0 oP� o <`�, DWG BY: DK TIED INTO EXISTING PVC.SUPPLY PIPING TO BE PEX TUBING. ��o-�ED Ry'`✓i CHK BY: PROVIDE ACCESSIBLE SHUT OFF VALVES FOR THE FLOOR I AND INDIVIDUAL SHUT OFF VALVES FOR LAVS AND TOILETS. �� I f DWG No: DEMOLITION PLAN - SECOND FLOORPROPOSED PLAN_-SECOND FLOOR REINFORCE ANY JOIST DRILLED FOR NEW DRAIN PIPING. �. °21d?b �O`r� I � A-100.00 4 5 DRILL ONLY IN THE CENTER OF A JOIST AND NEVER CLOSER 6 ELECTRICAL PLAN OF N, : �, A 021016 THAN 2"FROM THE EDGE. �,r CADO FILE No: PAGE: 3 : 3 Copyright©Synthesis Architecture,PLLC PROJECT TEAM ARCHITECTURAL ABBREVIATIONS SITE PLAN DRAWING INDEX NING H.B. - HO E BIB R - RADIUS ARCHITECT AC AIR CONDITIO S EC T ... :..:.::.... ..... ADJ. H.W.H-. HOT WATER HEATER R.D. ROOF DRAIN PAGE TITLE :. <` S Y N T H E S I S A.F.F. -ABOVE FINISH FLOOR HDR. - HEADER R.O. - ROUGH OPENING T-001 INDEX AND STANDARDS ...ARCHITECTURE P L L C A.P.. - ESS PANEL HDW. HARDWARE RE DRE UIRED T-002 GENERAL NOTES 15TB I BI TS LANE H.P. GH POINT RM - ROOM M HI P A-1URV 0 0 SURVEY, DEMO O ANDR - B I LU CONST UCTI ON PLAN B.F. BOILER FLUE �..;.. PORT WASHINGTON, NY 1 - HEIGHTnff B.OF - BOTTOM OF P: 516-883-9434 H.T.B.- HEATED TOWEL BAR SH. - SHELF BR - BEDROOMC• 46872-0286 HTG. HEATING SS - STAINLESS STEEL BUILDINGDANIEL K HSCONTACT. HVAC- - BLOCKING HEAT., & AIR COND. SYM. SYMMETRICAL EMAIL. DKOHS SYNTHE.r.ISARCHITECTURE.NETBLKGPROPOSE PROJE : :::: CLIENT BSMT- BASEMENTI.D. - INSIDE DIAMETER T.B. - TOWEL BAR SEE SURVEY ON PAGE A-100 C.B. - CATCH BASIN T.B.D.- TO BE DETERMINED CONVERT ONE BATHROOM INTO TWO BATHROOMS ON THE SECOND ARCHITECTURE CATHERINE NEEDHAM + TIM DONAHUE C.J. - CONTROL JOINT KIT. - KITCHEN T. OF - TOP OF 870 SOUND VIEW ROAD CAB. - CABINET T.P - TOILER PAPER FLOOR, RENOVATE ONE BATHROOM ON THE FIRST FLOOR, ON THE FIRST PLLC ORIENT, NY CLG. - CEILING L.C.C.- LEAD COATED COPPER TV - TELEVISION P: CATHERINE 914-263-4175 catherineneedhaml@gmail.com CMU - CONC. MAS. UNIT LAM. - LAMINATE T & G - TONGUE & GROOVE FLOOR CONVERT A WINDOW INTO A SLIDING DOOR AND A SLIDING DOOR DANIEL KOHS, R.A. P: TIM 914-263-3173 timotfiydonahue@hotmail.com CONC- CONCRETE LAV. - LAVATORY TELE. - TELEPHONE INTO A LARGER UNIT 15 T I B B I T S LANE CTR. - COUNTER LIB. - LIBRARY TYP. - TYPICAL PORT WASHINGTON CONTRACTOR DS - DOWNSPOUT L.P. - LOW POINT PHILIPPE JACQUET DW - DISHWASHER M.O. - MASONRY OPENING U.O.N- UNLESS OTHERWISE NEW YORK 11050 PHILIPPE JACQUET CONSTRUCTION DBL. - DOUBLE MAS. - MASONRY NOTED 873 SOUND VIEW ROAD D.L.O.- DAY LIGHT OPENING MAX. - MAXIMUM 6 4 6 - 8 7 2 - 0 2 8 6 P: 646-932-1880 SPIRITOFJACKMAN@YAHOO.COM DN - DOWN MIN. - MINIMUM VIF - VERIFY IN FIELD TYPICAL HEADER DETAIL 5 1 6 - 8 8 3 - 9 4 3 3 DR - DOOR VERT.- VERTICAL N/E - NOT ELECTRIFIED VEST.- VESTIBULE DKOHS @ ELEV.- ELEVATION N/A - NOT APPLICABLE LVLHEADER S SPECIFIED SYNTHESISARCHITECTURE.NET EQ. - EQUAL W/ - WITH EXIST- EXISTING N.I.C. - NOT IN CONTRACT W/W _ WALL TO WALL EXT. - EXTERIOR N.T.S.- NOT TO SCALE WP - WATERPROOF O.C. - ON CENTER WWF - WELDED WIRE FABRIC DRAWING SYMBOLS O.C. FURNISHED BY OTHERS O.D. - OUTSIDE DIAMETER WC -WATER CLOSET F.D. - FLOOR DRAIN OPG. - OPENING WD - WOOD 2 F.O.F.- FACE OF FINISH OPP. SIM.- OPPOSITE SIMILAR 4c> 40, 3 ELEVATION REFERENCE: DRAWING F.S. - FULL SIZE SITE DATA AND SHEET NUMBER FDN. - FOUNDATION PL. LAM. - PLASTIC LAMINATE a BEARING AREA AS FIN. - FINISH POL. - POLISHED SPECIFIED ELEVATION REFERENCE: FLR. - FLOOR PLYWD. - PLYWOOD LOCATION: 870 SOUND VIEW ROAD, ORIENT, NY FPSC - FIRE PROOF SELF CLOSING SECTION-BLOCK: 15-3 DRAWING AND SHEET NUMBER FTG. - FOOTING LOT: 50 MAP: 2777 SECTION REFERENCE: DRAWING GWB - GYPSUM WALLBOARD WOOD STUDS —� AND SHEET NUMBER WALL SYMBOLS DETAIL REFERENCE: DRAWINGUSE GROUP: RESIDENTIAL EXISTING WALL TO REMAIN AND SHEET NUMBER LOT AREA: 13,396.62 SF / .308 ACRE r••o.•� , �..•' PLYWD SUB FLOOR E ____ EXISTING WALL TO BE DEMOLISHED RIM JOIST FIRST FLOOR 0'-0' DATUM - CONTROL POINT a• UNRATED PARTITION DRAWING HISTORY: REVISION 20 GA. 2X4 METAL STUDS, 16" O.C. W/ 1 LAYER OF 5/8" GYPSUM BOARD ON BOTH SIDES AND 3" THERMAFIBER CONSTRUCTION CLASS: FRAMED, NO SPRINKLER INSULATION BATTS BETWEEN STUDS. O- WALL TAG PLUMBING RISER DIAGRAM NEW NON LOAD BEARING 1 HR. FIRE RATED PARTITION N 20 GA. 2X4 METAL STUDS, 16" O.C. W/ 1 LAYER OF 5/8" FIRECODE "X" GWB BOTH SIDES AND 3" THERMAFIBER INSULATION BATTS NORTH ARROW BETWEEN STUDS. MEA#80-98-M NEW NON LOAD BEARING 2 HR. FIRE RATED PARTITION 2-2 DIMENSION LINE 20 GA. 2X4 METAL STUDS 16" O.C. W/ 2 LAYER OF 5/8" FIRECODE "X" GWB BOTH SIDES AND 3" THERMAFIBER INSULATION BATTS I EXISTING SANITARY BETWEEN STUDS. MEA#80-98-M I RISER FIRST FLOOR PLAN DRAWING TITLE I EXISTING VENT ' SCALE:1/8"=,'-0, NEW NON LOAD BEARING 2 HR FIRE RATED SHAFT WALL 20 GA. 2.5" C-H STUDS (SYSTEM B), 24" O.C. W/2 LAYERS 5/8" I STACK z-WOOD RISERS ANNOTATION FIRECODE "X" SHEETROCK GYPSUM BOARD ON FINISHED SIDE, 1" I — -- - — — —— 2" 1.5"i — ———— —r — —— ——______ SHEETROCK GYPSUM LINER PANELS BETWEEN STUDS ON SHAFT I I I I I- — — — — — BED ROOM SIDE. MEA# 309-03-M I ( I I 11.511 I I I 403 ROOM NAME & NUMBER I 11.5" 11.5" 11.5" 11.5 1 1.5„ 11.5„ I I I I DOOR TAG SHEATHED EXISTING WALL I I I I 1 20 GA. 2"X2" METAL STUDS 16” O.C. W/ 1 LAYER OF 5/8” GWB ONE I I I I O WINDOW TAG FII I i i N 1 5 10 15 SIDES AND 2" THERMABER FOIL FACED INSULATION BATTS FURNITURE TAG BETWEEN STUDS. I i TOILET I I I LAV I TOILET I LAV 1 F-11 I TUB 1 I E709EQUIPMENT TAG NEW REINFORCED CONCRETE BLOCK WALL 2ND FLOOR I I SHOWER I I SHOWER MASONRY UNITS, FIRE RESISTANCE RATING OF 3 HOURS, 1000 FINISH TAG PSI MINIMUM WITH TYPE "S" MORTAR, MINIMUM #4 REBAR EVERY I 2" 2„ 2„ 2„ 4„ 2„ 2„ o° 24" AND HORIZONTAL BRIDGING EVERY 2'-0" VERTICALLY. MEA 291-03-M. SEE STRUCTURAL DRAWINGS FOR BLOCK SIZE AND I NEEDHAM/DONOHUE ® CARBON MONOXIDE DETECTOR REINFORCING REQUIRED. i 211 2„ 2 RESIDENCE 4„ 4„ 2., - - ILLUMINATED EXIT SIGN BRICK INFILL 4„ 4„ 4„ 11 PROJECT LOCATION COMMON BRICK EXTERIOR WYTHE AND 4"x8"x16" CMU INTERIOR ILLUMINATED EXIT SIGN WITH 870 SOUND VIEW ROAD E PATHWAY LIGHTS WYTHE. HORIZONTAL REINFORCEMENT EVERY 2'-0" VERTICALLY. I ORIENT, NY ___________ LINE BEHIND NEW STEEL STUD EXTERIOR WALL - 1 HOUR FIRE RATED 2X6 HEAVY GAUGE STEEL STUD WITH 3” MINERAL WOOL BATT —— — — —— LINE ABOVE INSULATION AND 3" FIBERGLASS INSULATION. INTERIOR FACE IS ONE LAYER 5/8" FIRECODE X GYP. BD. EXTERIOR IS 3/4" CDX — — — — PROPERTY LINE PLYWOOD, 1 1/2" FOIL FACED RIGID INSULATION, HOUSE WRAP AND 5/8" FIBERGLASS SHEATHING AND CEMENTITIOUS OR TITLE PAGE ACRYLIC STUCCO FINISH OF VARYING THICKNESS. MEA #216-08 DA;?C SEAL AND SIGNATURE: DATE: 7-14-21 NEW POURED REINFORCED CONCRETE WALL ��.�` cy, �5 ,�,� � r PROD No: 22106 3000PS1 MINIMUM POURED CONCRETE WITH WATERPROOFING w o�� 0 ��.� agp R DWG BY: DK ADMIXTURE. SEE STRUCTURAL DRAWINGS FOR REINFORCING * �E� ! oy�r� CHK BX BAR PLACEMENT AND ADDITIONAL BEARING CAPACITIES. �� oP "' �' DWG Y:Y: ,6 T-001 .00 FOF 02,076 FOF NE CADO FILE No: PAGE: 1 : 3 Copyright 0 Synthesis Architecture,PLLC PROJECT STANDARDS SMOKE DETECTING DEVICES 2016 NYCECC - ENERGY CODE REQUIREMENTS - RESIDENTIAL - ZONE 4A R402.4.5 RECESSED LIGHTING.RECESSED 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK STATE 1. EACH DWELLING UNIT SHALL BE EQUIPPED WITH AN APPROVED TYPE SMOKE LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE BUILDING CODE FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY DETECTOR DEVICE, RECEIVING PRIMARY POWER FROM THE BUILDINGILDING WIRING R302.1 INTERIOR DESIGN CONDIT N HE INTERIOR DESIGN SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITION N CONDITIONED AND .:::. :;> I:::::: HES N OTHER THAN R CIRCUIT DEVICES WITH N SWITCHES I THE CIRCUIT O H THE OVE C REQUIREMENTS AND THE BEST TRADE PRACTICES. TEMPERATURES USED FOR HEATING AND COOLING LOAD CALCULATIONS UNCONDITIONED SPACES. AL - L RECESSED LUMINAIRES SHALL BE IC RATED AND THE PROTECTING TH RANCH CIRCUIT ALL FILE ALL REQUIRED ROTEC C RCU WORK, THE CONTRACTOR SH A R Q SHALL BE A MAXI F 7 F 22 2 BEFORE COMMENCING W MUM O 2 C FOR HEATING AND MINIMUM ........... .........I......................... ( ) OF 75-F (24-C) LABELED AS HAVING AN AIR LEAKAGE RATE NOT MORE THAN 2.0 CFM. ALL ..... ........... T OF BUILDINGS, BTAIN ALL 2. SUCH SMOKE DETECTOR SHALL BE EITHER THE IONIZATION CHAMBER TYPE OR CERTIFICATES OF INSURANCE WITH THE DEPARTMENT O FOR COOLING. »::::: RECESSED LUMINAIRES SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN REQUIRED PERMITS, AND PAY ALL FEES REQUIREDUIRED BY GOVERNING NE W YOR K THE PHOTOELECTRIC ECTRIC TYP E. THE OUSING ANDTH INTERIOR WALL OR CEILING COVERING. CITY AGENCIES. 3. ALL SMOKE DETECTORS MUST BEINSTALLEDTALLED WITHIN 15,-0„ OF THE ENTRANCE R303.1.3 FENESTRATION - UNRATED 3. THE CONTRACTOR SHALL VERITY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO ANY SLEEPING ROOM WALL OR CEILING MOUNTED, AND INDICATED ON THE FENESTRATION SHALL COMPLY WITH SECTIONS TABLE R402.1.2 WHERE R402.4.6 TENANT SEPARATION WALLS TO COMMENCINGWO RK AND HALL REPORT ANY DISCREPANCIES BETWEEN EN PLAN AS PER N F.P.A. ELEMENTS DO NOT HAVE A MANUFACTURERS RATING FOLLOWING LO WIN DEFAULT FIRE SEPARATIONSATI S BETWEEN NDW LING UNITSIN TWO-FAMILY DWELLINGS AND DRAWINGS AND FIELD TO THE ARCHITECT.RITECT. 4. SMOKE DETECTORS SHALL ALSO LOCATED WITHIN EACH ROOM USED FOR - S FAC H U TORS ALLPPL A Y. MULTIPLE SINGLE- FAMILY DWELLINGS (TOWNHOUSES)TO USES LAT PU RPOSES. SHALL BE INSU D BUT SLEEPING USUALLY SHOWN SPECIFIED BU NECESSARY FOR 4 MINOR DETAILS T SUA OR SPECT - LS NO UNON METAL DOUBLE PANE SHALL BE U-.55 HG - .7 S C NO LE R-10 AND SS THAN THE WALLS SHALL BE AIR SEALED IN ............................. PROPER CONSTRUCTION OF ANY PART OF THE WORK SHALL BE INCLUDED AS IF 5. ALL SMOKE DETECTORS WITHIN A DWELLING UNIT SHALL BE INTERCONNECTED THEY WERE INDICATED IN THE DRAWINGS. IN SUCH A MANNER THAT ACTIVATION OF ONE ALARM ACTIVATES ALL ALARMS. NON METAL DOUBLE PANE SKYLIGHTS SHALL BE U-.1.05 ; SHGC - .7 ACCORDANCE WITH SECTION R402.4 OF THIS CHAPTER. WOOD DOORS SHALL BE U=.50 5. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH 6. SMOKE DETECTOR ALARM SHALL BE SUFFICIENT TO BE HEARD THROUGHOUT R402.3.3 - ONE WINDOW UPTO 15SF IS EXEMPTED FROM COMPLIANCE. SYSTEMS ARCHITECTURE REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING MANAGEMENT. THE SWELLING UNIT. R402.3.4 - ONE DOOR UPTO 24SF IS EXEMPTED FROM COMPLIANCE. PLLC 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF THE SITE, 7. A CERTIFICATE OF SATISFACTORY INSTALLATION FOR SMOKE DETECTORS CORK CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION SHALL BE FILED WITH THE DIVISION OF CODE ENFORCEMENT 10 DAYS AFTER R403.1.1 THERMOSTATS R401.3 CERTIFICATE (MANDATORY) .A PERMANENT CERTIFICATE SHALL BE ONE PROGRAMMABLE THERMOSTAT PER SYSTEM FOR HEATING OR COOLING DANIEL K O H S, R.A. AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND INSTALLATION. COMPLETED BY THE REGISTERED DESIGN PROFESSIONAL AND POSTED ON A SHALL BE CAPABLE OF CONTROLLING THE HEATING AND COOLING SYSTEM 15 T I B B I T S LANE BRACING FOR ALL. STRUCTURAL OR REMOVAL TASKS. THE CONTRACTOR SHALL WALL IN THE SPACE WHERE THE FURNACE IS LOCATED, A UTILITY ROOM OR AN ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT PORT WASHINGTON HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR CARBON MONOXIDE REQUIREMENTS APPROVED LOCATION INSIDE THE BUILDING. WHERE LOCATED ON AN DIFFERENT TIMES OF THE DAY. THIS THERMOSTAT SHALL INCLUDE THE NEW YORK 1 1 0 5 0 DURING THE EXECUTION OF THE WORK. 1. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED WITHIN 15' OF ALL ROOMS 7. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL PROVIDE ALL USED FOR SLEEPING PURPOSES, AND ALARM SHALL BE SUFFICIENT TO BE ELECTRICAL PANEL. THE CERTIFICATE SHALL DESCRIBE THE COMPONENTS CAPABILITY TO SET BACK OR TEMPORARILY OPERATE THE SYSTEM TO DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC.). HEARD THROUGHOUT THE DWELLING UNIT. DESIGNATED BY THE CODE. MAINTAIN ZONE TEMPERATURES DOWN TO 55°F (13°C) OR UP TO 85°F 6 4 6 - 8 7 2 - 0 2 8 6 8. PLUMBING AND ELECTRICAL WORK SHALL BE PERFORMED BY PERSONS LICENSED 2. CARBON MONOXIDE DETECTORS MAY BE COMBINED WITH (290C). THE THERMOSTAT SHALL INITIALLY BE PROGRAMMED WITH A HEATING 5 1 6 - 8 8 3 - 9 4 3 3 IN THEIR TRADES WHO SHALL ARRANGE FOR AND OBTAIN INSPECTIONS AND SMOKEDETECTION/ALARM DEVICES. R401.4 SOLAR-READY REQUIREMENTS (MANDATORY).DETACHED ONE-AND TEMPERATURE SET POINT NO HIGHER THAN 70°F (210C) AND A COOLING REQUIRED SIGN-OFFS. TWO-FAMILY DWELLINGS AND MULTIPLE SINGLE-FAMILY DWELLINGS TEMPERATURE SET POINT NO LOWER THAN 78°F (26°C). DKOHS @ 9. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED (TOWNHOUSES) SHALL MEET THE REQUIREMENTS OF APPENDIX RB OF THIS SYNTHESISARCHITECTURE.NET TO PERFORM ALL OF THE WORK INDICATED ON THE DRAWINGS, AND ALL OTHER PLUMBING AND DRAINAGE NOTES CODE WHEN APPLICABLE. R403.3.1 INSULATION 1. ALL PLUMBING AND GAS PIPING WORK SHALL BE INSTALLED IN STRICT WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. ACCORDANCE WITH THE REQUIREMENTS OF THE NYS BUILDING CODE AND SUPPLY AND RETURN DUCTS IN ATTICS SHALL BE INSULATED TO A MINIMUM OF 10. CONTRACTOR TO PROTECT ALL NEW WORK FROM DAMAGE UNTIL DELIVERY TO SUCH OTHER CODES HAVING JURISDICTION OVER PLUMBING WORK. BUILDING THERMAL ENVELOPE REQUIREMENTS R-8 WHERE 3 INCHES (76 MM) IN DIAMETER AND GREATER AND R-6 WHERE LESS CLIENT. 2. PLUMBING FIXTURES SHALL BE OF TYPE AND MANUFACTURE APPROVED FOR THAN 3 INCHES (76 MM) IN DIAMETER. SUPPLY AND RETURN DUCTS IN OTHER TABLE R402.1.2 PORTIONS OF THE BUILDING SHALL BE INSULATED TO A MINIMUM OF R-6 WHERE USE IN NEW YORK STATE FENESTRATION 3 INCHES (76 MM) IN DIAMETER OR GREATER AND R-4.2 WHERE LESS THAN 3 DEMOLITION NOTES 3. ALL PLUMBING FIXTURES SHALL MEET WATER SAVING PERFORMANCE WINDOW U=.32; SHGC .40 INCHES (76 MM) IN DIAMETER. STANDARDS SPECIFIED IN THE NYS CODE. SKYLIGHT U=.55; EXCEPTION: DUCTS LOCATED COMPLETELY INSIDE THE THERMAL ENVELOPE. 1. CONTRACTOR SHALL PERFORM ALL OPERATIONS OF DEMOLITION AND REMOVAL 4. ALL GAS-FIRED EQUIPMENT TO BE AGA OR MF-A APPROVED. WALLS INDICATED ON THE DRAWINGS AND AS MAY BE REQUIRED FOR THE PROPER 5. PLUMBING CONTRACTOR TO EXAMINE PROPOSED LAYOUT WITH REGARD TO WOOD FRAMED WALLS ABOVE GRADE R20 + R5 CONTINUOUS R403.3.2 SEALING DUCTS INSTALLATION OF THE FINISHED WORK. EXISTING FIELD CONDITIONS. AND SHALL NOTIFY ARCHITECT OF ANY STEEL FRAMED WALLS ABOVE GRADE R19+11.6 DUCTS, AIR HANDLERS AND FILTER BOXES SHALL BE SEALED. JOINTS AND 2. ALL EXISTING SURFACES AND EQUIPMENT TO REMAIN SHALL BE FULLY DISCREPANCIES BETWEEN ASSUMED FIELD CONDITIONS AND THOSE MASS WALLS (CONTINUOUS / CAVITY) R15 / 20 SEAMS SHALL COMPLY WITH THE NEW YORK CITY MECHANICAL CODE, AS PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ASSUME FULL ENCOUNTERED DURING CONSTRUCTION. PLUMBING CONTRACTOR SHALL BELOW GRADE (CONTINUOUS / CAVITY) R15 / 19 APPLICABLE. RESPONSIBILITY FOR DAMAGE AND SHALL MAKE REPAIRS REQUIRED WITHOUT INFORM ARCHITECT OF ANY REVISIONS TO PLAN WHICH SHALL BE NECESSARY, TENANT SEPARATION WALLS R10 EXCEPTIONS: 1. AIR-IMPERMEABLE SPRAY FOAM PRODUCTS SHALL BE ADDITIONAL COS717 TO THE OWNER. CONTRACTOR TO PROTECT PUBLIC AREAS AS BASED ON CONDITIONS UNCOVERED IN THE FIELD, IN ORDER TO INSTALL ALL FLOORS PERMITTED TO BE APPLIED WITHOUT ADDITIONAL JOINT SEALS. 2. FOR DUCTS REQUIRED BY BUILDING MANAGEMENT. FIXTURES, EQUIPMENT AND PIPING IN STRICT ACCORDANCE WITH THE 3. DEMOLITION SHALL INCLUDE REMOVAL, SLAB R10 4'-0" HAVING A STATIC PRESSURE CLASSIFICATION OF LESS THAN 2" WC. 500 PA DISCONNECTION BY ANY REQUIRED REQUIREMENTS OF THE NYC BUILDING CODE. � ( ) TRADES AND TRANSPORTATION FROM SITE. ALL WORK SHALL BE DONE 6. PLUMBING CONTRACTOR SHALL ARRANGE AND OBTAIN ALL INSPECTIONS AND JOIST FRAMING R30 CAREFULLY AND FEATLY, IN A SYSTEMATIC MANNER. REQUIRED SIGNOFFS. SLAB- UNHEATED R10 BELOW 24" R403.3.2.1 SEALED AIR HANDLER. 4. NO DEBRIS SHALL. BE ALLOWED TO ACCUMULATE ON THE SITE. DEBRIS SHALL BE 7. ALL FIXTURES SHALL HAVE HOT AND COLD WATER SHUT OFF VALVES. HEATED R15 BELOW 24" AIR HANDLERS SHALL HAVE A ANUFACTURER'S DESIGNATION FOR AN AIR REMOVED BY THE: CONTRACTOR AS THE JOB PROCEEDS. THE SITE SHALL BE 8. EACH FLOOR SHALL HAVE SHUT OFF VALVES INSTALLED AND ACCESSIBLE. ROOF LEAKAGE OF NO MORE THAN 2 PERCENT OF THE DESIGN AIR FLOW RATE LEFT BROOM CLEAN AT THE COMPLETION OF DEMOLITION. FOOD GARBAGE TO INSULATION ABOVE DECK R30 WHEN TESTED IN ACCORDANCE WITH ASHRAE 193 BE REMOVED DAILY. CEILINGS R49 5. NO STRUCTURAL ELEMENTS SHALL BE REMOVED UNLESS SHOWN ON DRAWINGS. R403.3.3 DUCT TESTING (MANDATORY). AREAS AFFECTED MUST BE ADEQUATELY SUPPORTED BY EITHER TEMPORARY R402.2.4 ACCESS HATCHES AND DOORS. DUCTS SHALL BE PRESSURE TESTED TO DETERMINE AIR LEAKAGE. TOTAL DRAWING HISTORY: SHORING OR NEW STRUCTURAL ELEMENTS AS REQUIRED TO PROTECT THE ACCESS DOORS FROM CONDITIONED SPACES TO UNCONDITIONED LEAKAGE SHALL BE MEASURED WITH A PRESSURE DIFFERENTIAL OF 0.1 STABILITY AND INTEGRITY OF THE EXISTING STRUCTURE. SPACES SUCH AS ATTICS AND CRAWL SPACES SHALL BE INCH W.G. (25 PA) ACROSS THE SYSTEM, 6. REMOVE ALL WIRING, PLUMBING, AND MECHANICAL EQUIPMENT AFFECTED BY WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE EXCEPTION: A DUCT AIR LEAKAGE TEST SHALL NOT BE REQUIRED WHERE THE REMOVAL OF PARTITIONS BACK TO IT SOURCE RISER OR PANEL. REMOVED PIPES INSULATION ON THE SURROUNDING SURFACES. ACCESS SHALL BE PROVIDED DUCTS AND AIR HANDLERS ARE LOCATED ENTIRELY WITHIN THE BUILDING AND/OR LINES SHALL BE CUT TO A POINT OF CONCEALMENT BEHIND OR BELOW TO ALL EQUIPMENT THAT PREVENTS DAMAGING THE INSULATION. THERMAL ENVELOPE. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL FINISH WORK, AND SHALL BE PROPERLY CAPPED OR PLUGGED. BE SIGNED BY THE PARTY CONDUCTING THE TEST. 7. RELOCATED PIPES AND ELECTRICAL LINES SHALL BE CAPPED FOR SAFETY AND R402.4 AIR LEAKAGE. TO PREVENT DAMAGE PRIOR TO THEIR REUSE IN THE FINISHED WORK. THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR R403.3.4 DUCT LEAKAGE (PRESCRIPTIVE). THE TOTAL LEAKAGE OF THE DUCTS, 8. PROVIDE ALL TEMPORARY SHORING AND BRACING, SIDEWALK BRIDGE, LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTIONS R402.4.1 WHERE MEASURED IN ACCORDANCE WITH SECTION R403.3.3, SHALL BE LESS OUTRIGGER NETS, SCAFFOLDING PROTECTION AS REQUIRED BY DEPARTMENT OF THROUGH R402.4.6. BUILDING THERMAL ENVELOPE.THE BUILDING THERMAL THAN OR EQUAL TO 4 CUBIC FEET PER MINUTE (113.3 L/MIN) PER 100 BUILDING RULES AND REGULATIONS ENVELOPE SHALL COMPLY WITH SECTIONS R402.4.1.1 AND R402.4.1.2. THE SQUARE FEET (9.29 M2) OF CONDITIONED FLOOR AREA. 9. REMOVE ALL BUILT INS, DEVICES, EQUIPMENT AND FIXTURES NOT INDICATED FOR SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR USE ON ARCHITECT'S PLANS FOR THE PROPOSED WORK. DIFFERENTIAL EXPANSION AND CONTRACTION. R403.4 MECHANICAL SYSTEM PIPING INSULATION MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE 105°F R402.4.1.2 TESTING (41°C) OR BELOW 55°F (13°C) SHALL BE INSULATED TO A MINIMUM OF R-3. STRUCTURAL STABILITY THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING PROTECTION OF PIPING INSULATION EXPOSED TO WEATHER SHALL BE 1. THE CONTROLLED INSPECTION ARCHITECT OR ENGINEER SHALL DETERMINE THE AN AIR LEAKAGE RATE NOT EXCEEDING THREE AIR CHANGES PER HOUR. PROTECTED FROM DAMAGE, INCLUDING THAT CAUSED BY SUNLIGHT, FREQUENCY OF INSPECTIONS NEEDED AND WHETHER HE OR SHE SHOULD TESTING SHALL BE CONDUCTED IN ACCORDANCE WITH ASTM E 779 OR ASTM E MOISTURE, EQUIPMENT MAINTENANCE AND WIND, AND SHALL PROVIDE INSPECT THE SITE PERSONALLY OR SEND A PERSON UNDER HIS OR HER DIRECT SUPERVISION. AT A MINIMUM, THE SITE MUST BE INSPECTED TWICE, ONCE ATA 1827 AND REPORTED AT A PRESSURE OF 0.2 INCH W.G. (50 PASCALS). TESTING SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION.PRE- CONSTRUCTION MEETING WITH THE CONTRACTOR AND ONCE DURING SHALL BE PERFORMED AT ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING THERMAL ENVELOPE. WHERE REQUIRED BY R403.5.1.1 HOT WATER CIRCULATION SYSTEMS CONSTRUCTION OPERATIONS. THE CODE OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD HEATED WATER CIRCULATION SYSTEMS SHALL BE PROVIDED WITH A PARTY. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE PREPARED CIRCULATION PUMP. THE SYSTEM RETURN PIPE SHALL BE A DEDICATED 1 5 10 15 FIRE RATED CONSTRUCTION AND SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE RETURN PIPE OR A COLD WATER SUPPLY PIPE. CONTROLS FOR N 1. ALL FIRE RATED ASSEMBLIES SHALL USE MATERIALS MARKED AS SUCH AND CODE OFFICIAL. CIRCULATING HOT WATER SYSTEM PUMPS SHALL START AND STOP THE SHALL BE INSTALLED IN COMPLIANCE WITH PRESCRIBED ASSEMBLY STANDARDS. PUMP BASED ON THE IDENTIFICATION OF A DEMAND FOR HOT WATER. 2. SEALANT SHALL 13E APPLIED AT THE TOP AND BOTTOM TRACKS OF RATED PARTITIONS TO PREVENT THE SPREAD OF SMOKE . R402.4.2 FIREPLACES R403.6 MECHANICAL VENTILATION 3. PIPE PENETRATIONS THROUGH RATED WALLS SHALL RECEIVE FIRE RATED FIREPLACE UNITS THAT ARE DESIGNED TO ALLOW AN OPEN BURN SHALL OUTDOOR AIR INTAKES AND EXHAUSTS SHALL HAVE AUTOMATIC OR GRAVITY CAULK AROUND THE PERIMETER OF THE PIPE ON BOTH SIDES OF THE WALL. HAVE TIGHT-FITTING FLUE DAMPERS OR TIGHT-FITTING DOORS. DAMPERS THAT CLOSE WHEN THE VENTILATION SYSTEM IS NOT OPERATING. RATED CAULK SHALL MATCH THE FIRE RATING OF THE WALL TIGHT-FITTING DOORS USED ON A FACTORY BUILT FIREPLACE LISTED AND FAN EFFICIENCY SHALL BE AS FOLLOWS: NEEDHAM/DONOHUE 4. ACCESS DOORS IN RATED WALLS SHAL BE LABELED AND BE OF THE SAME FIRE LABELED IN ACCORDANCE WITH UL 127 OR ON A FACTORY-BUILT RANGE HOOD AND IN LINE FANS 2.8 CFM/WATT RESIDENCE RATING AS THE WALL IN WHICH THEY ARE INSTALLED OR ONE QUARTER HOUR FIREPLACE UNIT LISTED AND LABELED INACCORDANCE WITH UL 127 SHALL BE BATHROOM AND UTILITY ROOMS 1.4 CFM/WATT UNDER 90 CFM LESS PER CODE. TESTED AND LISTED FOR SUCH FIREPLACE OR FIREPLACE UNIT. TIGHT-FITTING BATHROOM AND UTILITY ROOMS 2.8 CFM/WATT OVER 90 CFM PROJECT LOCATION 5. CONTRACTOR SHALL NOTIFY ARCHITECT WHEN FIREPROOFING IS COMPLETE DOORS USED ON A MASONRY FIREPLACE SHALL BE LISTED AND LABELED IN AND ARCHITECT WILL INSPECT THE WORK PRIOR TO INSTALLING ANY WORK ACCORDANCE WITH UL 907. ELECTRICAL POWER & LIGHTING SYSTEMS 870 SOUND VIEW ROAD WHICH WILL OBSTRUCT THE WORK FROM VIEW. ORIENT, NY R402.4.3 FENESTRATION AIR LEAKAGE R404.1 LIGHTING EQUIPMENT (MANDATORY) THE AIR LEAKAGE OF FENESTRATION ASSEMBLIES SHALL MEET THE FOLLOWING NOT LESS THAN 75 PERCENT OF THE LAMPS IN PERMANENTLY PROVISIONS IN ACCORDANCE WITH THE APPLICABLE REFERENCE TEST INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY. STANDARDS BY AN ACCREDITED INDEPENDENT TESTING LABORATORY AND EXCEPTION:LOW-VOLTAGELIGHTING. LABELED BY THE MANUFACTURER: WINDOWS .30 CFM ENERGY RATING INDEX COMPLIANCE ALTERNATIVE TO MODELING GENERAL NOTES & TABLES SWINGING DOORS .50 SKYLIGHTS .30 R406.3 ENERGY RATING INDEX. THE ENERGY RATING INDEX (ERI) SHALL BE A NUMERICAL I VALUE SEAL AND SIGNATURE: DATE: 7-14-21 R402.4.4 ROOMS CONTAINING FUEL-BURNING APPLIANCES THAT IS BASED ON A LINEAR SCALE CONSTRUCTED SUC ,� RI PROJ No: 22106 IN CLIMATE ZONES 3 - 8, WHERE OPEN COMBUSTION AIR DUCTS PROVIDE REFERENCE DESIGNHAS AN INDEX VALUE OF 100 AND A R IA�°�� DWG BY: DK COMBUSTION AIR TO OPEN COMBUSTION FUEL BURNING APPLIANCES, THE BUILDINGTHAT USES NO NET PURCHASED ENERGY HAS AN E I* 10. % SEpi Royer CHK BY: APPLIANCES AND COMBUSTION AIR OPENING SHALL BE LOCATED OUTSIDE THE EACH INTEGER VALUE ON THE SCALE SHALL / `� °P " �° DWG No: BUILDING THERMAL ENVELOPE OR ENCLOSED IN A ROOM, ISOLATED FROM CHANGE IN THE TOTAL ENERGY USE OF THE RATED DESI E b T E _002 .0 INSIDE THE THERMAL ENVELOPE. TOTAL ENERGY USE OF THE ERI REFERENCE DESIGN. THE E ' DER 0 EXCEPTIONS: DIRECT VENT APPLIANCES WITH BOTH INTAKE AND EXHAUST ALL ENERGY USED IN THE RESIDENTIAL BUILDING. 0 P '�sAgT 02'076 ' ..FoF NE's. CADO FILE No: PAGE: PIPES INSTALLED CONTINUOUS TO THE OUTSIDE. ZONE 4 ENERGY RATING INDEX IS 54. 2 . 3 Copyright 0 Synthesis Architecture,PLLC