Loading...
HomeMy WebLinkAbout47783-Z t TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 47783 _...__._.._ _.... ..._.... __. _.wm ._ Date: 5/5/2022 Permission is hereby granted to; ._. �.__�...�,.��..._�....____.�........___... Eisenberg Lester 925 Lona Creek Dr _w ......._.._-. .._.. ._._...__w_ ...._w _..__u_. ._.w_._. w_........ ....... ......_ .. . ........ ._......... . w _... ...___. .�k _n. ..w .... _._...__..._..... .. __... .... _.._ _..._w... ......._.w_. ..._....._. __._._......__..... ...... w....w_.__... _.___ ........ Southold, NY 11971.....�.....��...__..����.�._w_M�.�w�_...�...�.M....__-._.._.�..___...�W..._._.�.__.._�_..�.._.._...�........ .._..��..�...._.__.�..__�..�.__._.�,._w.�... legalize as-built AC as applied for. At premises located at: 925 Long Creek Dr., Southold SCTM #473889 ......._.__.._..�.m..�.�W..____�w._..._.._..._..�.µ.w�_.._........_...��_.,�.._M�.�_.�...,_w�_�w�.�w.......__M_�-�_.�µ�.....�_._ Sec/Block/Lot# 55.-3-27 Pursuant to application dated 4/1/2022 and approved by the Building Inspector. To expire on 11/4/2023. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO-ALTERATION TO DWELLING $50.00 Total: � � � $450.00 Building Inspector ...ww. ✓ ° ° TOWN OF SOUTHOLD—BUILDING DEPARTMENT M Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 � Telephone(631) 765-1802 Fax(631)765-9502 ht��im Date Received AIPPLICA 110N FOR BUILDING PE M!"I" f`{yIII�S, For Office Use Only D�J u, ` PERMIT NO. Building Inspector� NG DEPT Applications and forms must be filled out in their entire Incomplete h01 1 1 TH PP entirety. P "�" `l : " q NTi�Ot.i) applications will not be accepted. Where the Applicant is not the owner,an Owners Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: ` Crr Name: !!QS P°C SCTM#1000- '"" 3— 027 Project Address: Phone#: - (—I f Email: Mailing Address: CONTACT PERSON: Name: Mailing Address: C,XCJ 7�; Phone#: (-P-;/1 � Email: 71� DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addiiti n 216terAtion ❑Repair ❑Demolition Estimated Cost of Project: ❑Other Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? ❑Yes 10<0 1 PROPERTY INFORMATION Existing use of property: Aoos.R - Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect t -9 O this property? ❑YeskNo IF YES, PROVIDE A COPY. rho Cheri,bill Afte Reaiding'. The owner/contractor/desi'gr�professional Is responsible for all drainage and storm wv r issues as provided by pter 236 of the Town Code. APPLICATION is HEREBY MADE to the Building Department for the Issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buildings)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. ApplicatioSubMitt d By(print name): ❑Auth rig d Agent nOwner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OFC I . ) t C., (— LA,: being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the "-. (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of �" P� ° N� rV a lic S 11A PERKINS 14 0 ublic.State of New York PROPERTY E u l � ) � No.01 PE6130636 .._. ..... � _ ... ualified In Suffolk E'oun (Where the applicant is not the owngorammission Expires July 16, I, Q r residing at CLttL W1''C �'FAA V 1 do hereby authorize Lcj to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Ilk tint Owner's Name 2 Op 0 BUILDING DEPARTMENT- Electrical Inspectr � ' TOWN OF SOUTHOLD w cm �w Town Hall Annex - 54375 Main Road - PO Box 11779 '' 01,n Southold, New York 11971-0959 ' Telephone (631) 765-1802 - FAX (631) 765-9502 ro err southoldtownn . oar — seand southoldtownn . oar APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Ll - 2-Z-- Company ZCompany Name: Name: ��►— License No.: _ email: mw yr e- In 3 .(om Phone No: Vl request an email copy of Certificate of Co pliance Address.: JOB SITE INFORMATION (AII Information Required) Name: ° Address: 7_5 06c Cross Street: Phone No.: ( -- c.& ( &D - -71, Bldg.Permit#: email: Tax Ma a District: 1000 Section: Block: Lot:, '" q BRIEF DESCRIPTION OF WORK (Please Print Clearly) Check All That Apply: Is job ready for inspection?: E]Y' E S [ NG, ❑Rough In !nal Do you need a Temp Certificate?: DYES ,, NO Issued On Temp Information: (AII information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground [:]overhead 17-1 # Underground Laterals 01 2 [jH Frame❑Pole Work done on Service? QY L]N Additional Information: �J PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx COMPANY INC . Acondicionador de Aire Central Modelo : RA1324 , 1NA Tension Nominal : - 2081230 V Fases : l Frecuencia : 60 Hz Corriente Nominal : 15/15 A Requiere Tierra Fisica ENSAMBLADO EN MEXICO _ Leer Manual de Instalacion Y Qperacion Anexo 92-22050-20-01 MII�uUNIWWVMUI�VV YM�VNIuf�dl l��lll������ ����fi V llllll�uuyy��uu���E V ��� 104i.. � ,,,,,.. Ades 1 o 1*0er amso a 10S tOrminales, S cirCultos do alimentseffin deben ser m m i wwwmwu X41 Ron amu' rig Y i m r � � y UYW� �i q � i - 1, „/ ��,: i=e �, �/ -,,, / ,,,, ✓j ✓rill%%/i"i/// ' „��/ rlii � / .j %,�i�, �f �,' If,, % ............ / MODEL NO./ 'MODELS N° RAI-324BJINA MFD. /FAB 06/2020 , SER1 At NO. / No DE SERI W262057425 QUT000R ,USE/ UTILISATION EIS EXTRIEURt COMPRESSOR CODE / CODES DE COMPR,ESSEUR 9529 VOLTS -20c�/230 PHASE. I _H T . . . ..:ERZ . 60 COMPRESSOR/ COMPRES'SEUR R. L.A. 11.2/11 .2 L.R.A. 60.,8. OUTDOOR FAN MOTOR/ MOTEUR VENTIL. EXT. F. L.A. 0. 76 H. 1/7 MIN. ., SUPPLY CIRCUIT AMPACITY/ 15/15' A COURANT I ADMI SSABLE D1ALIM.! K,1N. MAX. FUSE OR CKT. B�KR. SIZE*/ CAS . MAX . DE FUSIBLE/DISJ* 25/25 A, MIN. FUSE OR CKT. BRK. SIZE*/ CAL. MIN. DE FUSIBLE/DISJ* 20120 A DESIGN PRESSURE HIGH/ PRESSION NOMI NALE .R'AUTE 450 PS'IO/3`102 kPa DESIGN PRESSURE' LOW/ PRESSION NOMINALE BASSf 2,50 PSIG/1723 kPa OUTDOOR UNITS FACTORY CHARGE/ CHARGE USINE D' UNITCS EXTERIEUR' 66 Oz/1871g R410A TOTAL SYSTEM CHARGE/ R410A CHARGE TOTALS DU SYSTEMS SEE 14STRUCTIONS INSIDE ACCESS PANEL j VOIR LES CHARGE 1t'STRUCTIONS b L'INT RJUR OU PANNEAU D'ACC S „ : RHEEM SALES COMPANY FORT SM I T1,1, ARKANS/AvS INSTALL PROHIBITED I°N SOUTHEAST ANO-SA p *WACR TYPE Qa � Eo I EAKER FOR U.S.A./; x�y , DTSJUNCTEUft pIFFE,RIE�NTIE � 111 "X-CM ,%rt4QLF- POLE 'alt �Or ,C ►R Potential t all terminals duringcycle. CF-U SO IpOII est Possible QTI Pendant l l " r6t. s 1 a 11 s AIR CONDITIONER nO EL NO. MAC248AKAS MODEL N0. PART Nin. 1088454-0339 SERIAL NO. E032430249 MFR NO. MAX FUSE or CKT . BKR H CR ,BYRE IN USAF 40 RATED VOLTAGE ' ACAS VOLTAGE MIN. 1 I R HZ MAX. MINIMUM CIRCUIT AMPACiTY: COMPRESOR: _HP PH FLA RLA LRA FAN= 11 , OUTDOOR UNIT SH I PP I i�G CHARG 1 , �i- T ED: R�' 130 OZ TOTAL OPERATING CHARGE: TO DETERMINE TOTAL OPERATING CHARGE REFER TO TECH SHEET OR INSTALLATION INSTRUCTIONS DESIGN PRESSURE(PS I G) :HIGH 3ee LOW 150 FOR OUTDOOR (KPa)HIGH 2068 (KPe)LOW USE MAX DESIGN/WORKING 16 '4 PRESSURE: f()Q PSIG 4829 KPA ill 11 µ J Madel Number NAC24BAKAS III I Serial N��mbe 24 , �� ESS S24S L IJL u STtD UCTION OF *`I 3R34 "N'TIERNATIONAL COMFORT PR ODUCTS C4RPQ TIQN(U SA) HE ,/ J PYI, i�ld4Y r Nf 1VMyNJNUqNI q# N(%r kmw>'r f ;�'i IIIIIIIIIIIIII IIIIII�VIII"' ouuuuum u�u�u�u�u�u�u�u�u�u�u�u�u�u�u�u�i�i�i�i�u�u�u�u�u�u�u�u�i��m i i i uulllllll��� u i r- ,. ^rorwna✓�.�,. r M; �n ,,� / J Illrlln&� � r, / ,r 'r, / W� a wru%'r�✓ ,o,l�lJf.' � //f r/ i /iiii � � lll% uuul��1 /r ' � �� / '..�, rM�Wrrr✓ra... ,,,;,,,, j �i / rs � �I,,. ,�„ r�;�fy I' a %/ /�j �r „o irk „ ��' of///j/ ” '� �� r� ,; �Ir r %/�%/�aii�//� �i ;, i i � � �`iii �rir%� v ..., i i ilii/i' i. � r il�/ f�/ i� ,� it e � �i� %� '% r Jere g�� i 'ii/ i„ f�J /-% �� � ��i f'l��j� � /��� / /iii �% ��/✓� ������ ��il� / i , iii i �� � �i //O///® �,i� f!i f //r / d >; //�/a ii f, �f � %�// %�/� �` L � i ,/ �i//ii ��, lf%' �� ' „ ��a%'r� /�� U �/ �r�% rr ��/ /� // rr �, j//� ^Ilp f rv� ��� i %lir // ' t i%ii �f��i rr/ r nf�i �i Il`ji% r r j�/�� �i� % � / ��� , �r�- J/��� r � � �i �G� ���%%%/�/iI /ii iii %%/ � i��/ lir�//��� �iF/ %(f/ii%iii ��� i/ l�j ���� � / i i �i, �, � � �� ,,, iy �i i�i l/���i � � iii%/ , , � ;, /� � ���im �v/� °� �� // �/ir 1 F '%% ii �i/////r °I u������"vl' i l ���� i � �i i o� �. ���� � I / �%%�`i r i �j/iii�/, ��f � im�4 i. �� � � y�y�r f� �j� r iiU��di�, %�/i �J %i %moi'�i i�, ' �% ��� �� �i, "8 luuuuu'u�i"°"�° �ii r„ r���/�' r ��' ��// f�%'� '% � / 1/ 0�, 1 l%„ ��% �%%; mel Air Air Conditioners 0 RA13 Series t t The new degree of comfort" Rheem Classic° Series Air Conditioners RA13 Series Efficiencies up to 15 SEER/13 EER U �III I�IIIIII�I�INp�i�l� Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] Cells i' "Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystargov." P,li, IMi� IIII i;, y I�I I ili Ili III�i jil Ili ilj'I' • Composite base pan-dampens sound,captures louver panels, • Diagnostic service window with two-fastener opening- eliminates corrosion and reduces number of fasteners needed provides access to the high and low pressure. • Powder coat paint system-for a long lasting professional finish • External gauge port access-allows easy connection of • Scroll compressor-uses 70%fewer moving parts for higher `low-loss"gauge ports efficiency and increased reliability • Single-row condenser coil-makes unit lighter and allows • Modern cabinet aesthetics-increased curb appeal with visu- thorough coil cleaning to maintain"out of the box" ally appealing design performance • Curved louver panels-provide ultimate coil protection, • 35%fewer cabinet fasteners and fastener-free base-allow enhance cabinet strength,and increased cabinet rigidity for faster access to internal components and hassle-free • Optimized fan orifice-optimizes airflow and reduces unit panel removal sound • Service trays-hold fasteners or caps during service calls • Rust resistant screws-confirmed through 1500-hour salt • QR code-provides technical information on demand for spray testing faster service calls • PlusOneTM Expanded Valve Space-3"-4"-5"service valve • Fan motor harness with extra long wires allows unit top to be space-provides a minimum working area of 27-square removed without disconnecting fan wire. inches for easier access • PlusOneTm Triple Service Access-15" wide, industry lead- ing corner service access-makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed,for faster coil cleaning and easier cabinet reassembly FORM NO.All-221 REV.8 Air Table of Contents RA13 Series TABLE OF CONTENTS StandardFeature......................................................................................................3 AvailableSKUs ........................................................................................................,3 Features&Benefits .......................................»..,.,,.......,.....,.............W.....,,,........,.,.4-5 Model Number Identification ................................................................................6-7 General Data/Electrical Data ....................................................................................8 Accessories ............................................................................................................9 WeightedSound Power............................................................................................9 UnitDimensions......................................................................................................10 Clearances..............................................................................................................11 WiringDiagrams .............................................».............,.....,....,...,,....„......,..„,.,,.,...12 Application Guidelines............................................................................................12 Refrigerant Line Size Information......................................................................13-16 Performance Data LL......,....a... .. ........................................................ 17 GuideSpecifications ..............................................................................................18 LimitedWarranty....................................................................................................19 Air Standard Feature/Available SKUs 0 RA13 Series Standard Feature Table STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-41 Oa Refrigerant ✓ ✓ ✓ ✓ ✓ ✓ J Maximum SEER 14.5 14.0 15.0 15.0 14.0 13.5 13.5 Maximum EER 12.5 12.0 13.0 13.0 12.0 11.5 11.5 Scroll Compressor J J J J J ✓ If Field Installed Filter Drier J ✓ ✓ ✓ J ✓ ✓ Front Seating Service Valves J J J J J ✓ _✓ Internal Pressure Relief Valve ✓ ✓ ✓ J J ✓ ✓ Internal Thermal Overload ✓ J ✓ ✓ ✓ J ✓ Long Line capability ✓ ✓ ✓ ✓ ✓ ✓ ✓ Low Ambient capability with Kit ✓ ✓ ✓ ✓ J ✓ J 3-4-5 Expanded Valve Space J _ ✓ ✓ J ✓ ✓ ✓ Composite Basepan ✓ J J ✓ J J ✓ 2 Screw Control Box Access J ✓ ✓ J ✓ ✓ ✓ 15"Access to Internal Components J ✓ J J J ✓ ✓ Quick release louver panel design ✓ ✓ ✓ ✓ ✓ ✓ J No fasteners to remove along bottom ✓ ✓ ✓ ✓ J J ✓ Optimized Venturi Airflow ✓ ✓ ✓ J ✓ ✓ J Single row condenser coil ✓ ✓ J J ✓ ✓ ✓ Powder coated paint ✓ J ✓ ✓ ✓ ✓ ✓ Rust resistant screws J J ✓ J ✓ ✓ 1 J OR code J ✓ ✓ ✓ ✓ J J External gauge ports ✓ ✓ J ✓ ✓ J J Service trays J ✓ ✓ J ✓ ✓ ✓ ✓=Standard Available SKUs Available Models Description RA1318AJl NA Classics Series 1 1/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1318AJl NB Classic®Series 11/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1324BJl NA Classic®Series 2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1324BJl NB Classics Series 2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1330AJl NA Classic®Series 21/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1330AJl NB Classic®Series 2 1/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336ACl NB Classics Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336ADl NB Classics Series 3 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1336AJl NA Classics Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336AJl NB Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1342ACl NB Classic®Series 31/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1342ADl NB Classics Series 31/2 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1342AJl NA Classics Series 31/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1342AJl NB Classics Series 31/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348AC1 NB Classics Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348ADl NB Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1348AJl NA Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348AJl NB Classics Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1360ACl NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1360ADl NB Classics Series 5 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1360AJlNA Classics Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1360AJl NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 --0' Air Features&Benefits —a RA13 Series Introduction to RA13 Air Conditioner The RA13 is our 13 SEER air conditioner and is part of the ; Rheem air conditioner product line that extends from 13 to 20 SEER.This highly featured and reliable air conditioner is � , 1 designed for years of reliable, efficient operation when matched with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. Our unique composite base( 1❑)reduces sound emission, elimi- ......w.... nates rattles,significantly reduces fasteners, eliminates corro- If in the rare event, greater access is needed to internal compo- sion and has integrated brass compressor attachment inserts nents,such as the compressor,the entire corner of the unit can ([fl). Furthermore it has incorporated into the design, water be removed along with the top cover assembly to have unprece- management features, means for hand placement( 3❑)for unit dented access to interior of the unit(H). Extra wire length is maneuvering,screw trays(®)and inserts for lifting off unit incorporated into each outdoor fan and compressor so top pad.([ ],) cover and control panel can be positioned next to the unit.With _w___,,,,,,,,,,,,,,,,,,, minimal effort the plug can be removed from the compressor 0 and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit Outdoor coil heights range from as short as 22"to 28",aiding access to the compressor. Disassembly to this degree and com- plete reassembly only takes a first time service technician less than 10 minutes.(g) wwwwwww_.................. ................_..�..._wwwwww................ww.._.. .. ..... .....m._ ......... ,a Service Valves(©)are rigidly mounted in the composite base with 3" between suction and discharge valves,4" clearance below service valves and a minimum of 5" above the service valves,creating industry leading installation ease.The minimum 27 square-inches around the service valves allows ample room is to remove service valve Schrader prior to brazing, plenty of clear- is ,r> ance for easy brazing of the suction and discharge lines to ser- "° '®"". vice valve outlets, easy access and hookup of low loss refriger- All units utilize strong formed louver panels which provide indus- ant gauges(❑� ),and access to the service valve caps for try leading coil protection. Louver removal for coil cleaning is opening. For applications with long-line lengths up to 250 feet accomplished by removing one screw and lifting the panel out of total equivalent length, up to 200 feet condenser above evapora- the composite base pan. (n)All RA13 units utilize single row tor,or up to 80 feet evaporator above condenser,the long-line coils(,$)making cleaning easy and complete, restoring the instructions in the installation manual should be followed. performance of the air conditioner back to out of the box perfor- _..................... mance levels year after year. di � gr iii . _____........�........................ ... Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover, revealing the — e bearings and is inherently industry's largest 15"wide and 14"tall control area aWith all this room in the control area the high voltage electrical ) protected.The motor is totally enclosed for maximum protection The outdoor fan motor has sleeve l whip(� from weather,dust and corrosion.Access to the outdoor fan is can easily be inserted through the right size opening in the bot- made by removing four fasteners from the fan grille.The outdoor tom of the control area.Routing it leads directly to contractor fan can be removed from the fan grille by removing 4 fasteners lugs for connection.The low voltage control wires(10)are easily in the rare case outdoor fan motor fails. connected to units low voltage wiring.If contactor or capacitor („)needs to be replaced there is more than adequate space to Each cabinet has optimized composite(1s)fan orifice assuring make the repair. Furthermore,if high pressure and low pressure efficient and quiet airflow. model was not purchased but is desired to be installed in the ..... .............. ------"""--------- field, l crews,to access the high and low side i s chrader fittings for y _ ','Y6il' !�Ae'i� VI'' 'iii l')ll i"1y;91'id��1 A F field installation.The entire corner can be removed providing ultimate access to install the high and low pressure switch.(13) 00 Air Features&Benefits a RA13 Series The entire cabinet has powder post paint(20)achieving 1000 Optional Accessories hour salt spray rating, allowing the cabinet to retain its aesthetics (Refer to accessory chart for model#) throughout its life........ Compressor Crankcase Heater _. '24 Protects against refrigerant migration that can occur during low ambient operation Compressor Sound Cover • Reinforced vinyl compressor cover containing a 11/2 inch thick batt of fiberglass insulation • Open edges are sealed with a one-inch wide hook and loop fastening tape Scroll compressors with standard internal pressure relief and Compressor Hard Start Kit internal thermal overload are used on all capacities assuring • Single-phase units are equipped with a PSC compressor longevity of high efficient and quiet operation for the life of the motor,this type of motor normally does not need a potential product. relay and start capacitor Each unit is shipped with filter drier for field installation and will • Kit may be required to increase the compressor starting trap any moisture or dirt that could contaminate the refrigerant torque, in conditions such as low voltage system. Low Ambient Kit .............--- •Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls •This Kit can be added in the field enabling unit to operate properly down to 0° in the cooling mode • Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit All cabinets have itid5_sft —fead'kn--g—structural strength due to the 3"/6"/12" composite base pan(r ), interlocking corner post(9A),formed • Gray high density polyethylene feet are available to raise unit curved louver panels(23)and drawn top cover(24])making it off of mounting surface away from moisture the most durable cabinet on the market today. Low Pressure Each RA13 capacity has undergone rigorous psychometric test- • Can be added in field enabling the unit to shut off compressor ing to assure performance ratings of capacity,SEER and EER on loss of charge per AHRI Standard 210/240 rating conditions.Also NOTE: Unit can be purchased with high and low pressure each unit bears the UL mark and each unit is certified a 9L installed at factory.(Refer to SKU list) to UL 1995 safety standards. us,m High Pressure Each unit has undergone specific strain and modal testing to • Can be added in field enabling unit to shut off compressor if assure tubing(25)is outside the units natural frequency and that unit loses outdoor fan operation. the suction and discharge lines connected to the compressor withstand any starting,steady state operation or shut down NOTE: Unit can be purchased with high and low pressure forces imposed by the compressor. installed at factory.(Refer to SKU list) All units have been sound tested in sound chamber to AHRI 270 Decorative Top rating conditions, and A-weighted Sound Power Level tables •Can be installed on fan grille produced,assuring units have acceptable noise qualities(see page 9). Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the RA13 range from as low as 73 dBA to 79 dBA. All units have been ship tested to assure units meet stringent "over the road"shipping conditions. As manufactured all units in the RA13 family have cooling capa- bility to 55°F Addition of low ambient control will allow the unit to operate down to 0°F. Factory testing is performed on each unit.All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned,assuring correct component uti- lization for a given unit capacity and voltage.All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled,each units'complete refrigerant system is helium leak tested.All units are fully charged from the factory for up to 15 feet of piping.All units are factory run tested. The RA13 has a 10-year conditional compressor and parts war- ranty(registration required). Air Model Number Identification RA13 Series c m I � Q o-= ¢ . i 'a CD z O v Z t I 'a s z G C..,)v CD C Ci O N y a7 h U) a a� C) y CT Q� y W r L N = Qd h c p r N7 am ¢ O a = O CZ C U C� UM N M C W U N O id V � C7)U - o EC E C � z1 ` � C C, V Z( o >. = O EU c o C.' Eo ��� O Z U Z O y O a a z UZ �I .� . N CU C > U 2 O N N CD6 N CL .21 O. 2 0 f N TI H CT0C� OO fnA:—� r COr r N>D- O M O CO c E O C')C1) co�D� oma' >>y Cm oO O o o HM 'S LU w '- 71 yam+ O O O N N COO C W D_ O N N CD Cm CCC D cc m �J L xi 7p O 1=1N N R O C-C�CM Fa a W rn �M M �. y BUD 0 CO LU LU col c� CO � m LM in 2 'm y Cn CD Lu Cn � • c a0 CO.) n a d O Cn r N y Lr) U') 7 rl .� V: ¢ r N N = Y Y Y1 Y Y Y � m OOMMLO— r-w a �♦� IIS I�OO O N-I� YY M U,YY YYY O Cj= N O r*-:UP M O U') Y Y Y� NIR Z'4: uuGuO CV�t` Cr) W CD- C14 AH 0000CoCoo v M= CT=a hoc ro�ovr�� a Cam 0000000 NI CH c000000 DO4OCI C\ OO vm 0000000 N� == o00o d rNMM".;r :TCD covocco MF- o00o a, 1 NT M V V CD V m O O O O C DOTOCCN MCD --zrC0000 O O�O CO N W O N M V cc .1 r N M M V (D N M M V CO Cn -Rt ccCOo N CO V(D � W m W Cr.Col W w w w w w > M Lu Lu Lu Lu Lu R r LUcc cn cn(n CO U)Ui yCO T rl Y.I rrr0 —� Cn N H N d p a C T r r r r N U.1 a C X: 00 ' -0L • ~ i¢U v (D d • LL.2 O C `m O CJ Y U p C ar _ `u O .. U c9a - O.I CM Som a� a; x L)I g= C CO o m Qc6 CL v w m m o U M O Q CO E Of C c N O C y a v E E a �Ncc CD ¢I L ¢I L CO Cr_ d m 2 m 2 t u --on Air Model Number Identification a RA13 Series � m n c a + g o m L m CO O V CD ti p af6.� O CL 0L 09 O C3 O L_-W Q... x-o Mo 3 U o "- x o z c o LC K c a x z N l 00 4! a NI o XN QI c m n X rn g y r d U C O - O M 3 CD Y i Oi a� O �C OO _ C C U C C00 N 100 ,C C inn NL t6 CD CO 0 o QI �Nc Co v ttt M N n nM 7 77 UnUn ¢te n a+z c r`r v in n r N N y L T' � O r a3 i i r� C9 N N C C7 rfNN m- rr - v E V N N y E E O = O C ZI C E U O E c LO .O U p O c� UZ M o a Q7b LL N �I t M.2 C= a Q r O N N O M Q Cm. r N N d ONM CO U7 O M V Ln g y r E U C Q U co w C Cm CO d N O Y YY Y Y C O CaCa d to �uNMQ' FV m 7 I�-LU w LU �p O 0 T 6Z N4 o 0 0 0 o g 0 H w d n s� 00000 �m C5 Ui L6 rN� U,I1-OTL2 w sO zt�4 a� N_ TJ w w L � O O Or r r '� C!�W�2 S N M V L{7 fD r- M C U CV'.0 CD-q-CO m s In if3 �= 000000 CI O. O 00000 p n 7 N N r c� o0000o Cm V�a0"Y I-C O M r 3 r r N N y L Q U 61 000LL)O LC) O- vCDr-aOoT 0 0 0 O r M Y Y Y Y y M LC)r-M a X O LO O LO cc m cs n CD y m ?E•c0 t�) oH� 0000 C U 0 0 C 5 0 0 0 p C a l--- 'DC7 U m 0 0 C:> O Q I r �!d 0 a�c c •S CD M O C N M•7 CO tL6 fn O_yO_ • a <a OUJ N COM<7 C00 OD C/) `s • U U)d CO • O c Q L1 •- OU? C QC) .� O.O p Cn > p d C 6i r C/)U H Cl C6 >I O y M N O O c c r U y O) o `o X� m 2 Cp = O >UF- NI mo m o R 0 CU C i >� inCl?s `0 3 in mo d m y O 9v C!} _ rN rl CD� moo m U wwwww 3� �»�� yQ rn� i U y LL LL LL L L w Ob N Q Q Q Q Q N P2 d N m = co y f M Cli MM� CO8 y _ O E s O Y O ', I O m ¢ c a C W _= E CD U � H E v E v E Q �I Air General Data/Electrical Data �i RA13 Series Physical Data PHYSICAL DATA Model No. RA1318 RA1324 1 RA1330 RA1336 RA1342 E�4 1348 RA1360 Nominal Tonnage 1.5 2.0 2.5 3.0 .0 5.0 Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oz.' 54 60 72 86 105 106 148 Compressor Type Scroll Outdoor Coil Net face area-Outer Coil 5.9 9.1 9.1 12.1 14.2 14.8 18.8 Net face area-Inner Coil --• - -- -_ - -° Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 22 18 22 22 22 22 22 Outdoor Fan Diameter-in. 20 20 20 20 20 24 26 Number of blades 2 2 3 3 2 3 2 Motor hp 1/8 1/8 1/4 1/4 1/8 1/6 1/5 CFM 2040 2325 2795 2900 2465 4145 3870 RPM 1075 1075 1075 1075 1075 850 820 watts 144 137 189 186 176 279 1 235 Shipping weight-lbs. 127 142 163 164 195 202 235 Operating weight-lbs. 120 135 156 1 157 188 195 228 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)2 20 25 30 35 40 50 60 Minimum circuit ampacity3 13 15 18 23 24 29 35 Compressor -::T Rated load amps 9.7 11.2 12.8 16.7 17.9 21.8 26.4 Locked rotor amps 48 60.8 64 83.9 112 117 134 Condenser Fan Motor Full load amps 0.7 0.7 1.3 1.3 0.7 1 1.2 Locked rotor amps 1.3 1.3 2.5 2.6 1.3 2.2 2.0 Line Voltage Data (Volts-Phase-Hz) --- - - 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection(ampsy - - -- 20 30 30 35 Minimum circuit ampacity3 15 18 19 22 Compressor Rated load amps 10.4 13.2 13.7 16 Locked rotor amps - 73 88 83.1 110 Condenser Fan Motor Full load amps - - 1.3 0.7 1 1.3 Locked rotor amps 2.6 1.3 2.2 2.0 Line Voltage Data (Volts-Phase-Hz) -- - - 480-3-60 480-3-60 480-3-60 480-3-60 Maximum overcurrent protection(amps)2 15 15 15 15 Minimum circuit ampacity3 M-- 8 8 1 9 11 Compressor Rated load amps - 5.8 6.0 1 6.2 7.8 Locked rotor amps - 38 44 41 52 Condenser Fan Motor Full load amps - - 6 3 .6 6 Locked rotor amps - - -- 2.5 .9 1.6 1.1 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 'Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. 8 INTEGRATED • • •- Air Accessories/Weighted Sound Power D RA13 Series Accessories Model No. RA1318 RA1324 RA1330 RAI 336 RAI 342 RAI 348 RA1360 Compressor crankcase heater* 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Compressor time delay RXMD-1301 RXMD-1301 RXMD-601 RXMD-601 RXMD-1301 RXMD-1301 RXMD-1301 RXAC A07 Tow pressure control RXAC-A07 RXAC-A07RXAC A07 RXAC A07 RXAC A07 RXAC A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61 AMG120/240V61 AMG120l240V Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 *Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dBA) RA13 Sound Power Level Full Octave Linear Sound Power Level dB-Center Frequency-Hz Model Sound Power Level[dB(A)] 125 250 500 1000 2000 4000 8000 RA1318 72.0 51.7 58.3 61.5 61.1 57.0 54.0 47.0 RA1324 75.0 55.4 60.3 64.7 66.4 62.6 58.0 52.4 RA1330 78.0 51.4 67.1 67.5 68.2 65.5 59.8 53.6 RA1336 77.0 55.1 66.1 66.9 68.2 64.6 60.7 55.6 RA1342 73.0 48.9 56.1 62.9 62.2 61.1 55.2 50.2 RA1348 76.0 51.4 59.6 65.2 65.9 64.3 58.5 53.7 RA1360 78.0 51.7 60.9 66.9 70.4 63.5 57.4 53.8 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) --0- AirUnit Dimensions "a ` p RA13 Series Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) N0. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA1318 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1324 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1330 25 635 1 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1336 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1342 31 787 29.75 755 1 29.75 755 1 32.75 831 32.38 822 32.38 822 RA1348 27 685 33.75 857 33.75 857 28.75 730 36.38 924 36.38 924 RA1360 31 787 35.75 908 35.75 908 32.75 831 38.38 1 974 38.38 974 ALLOW 60"[1524 mm] OF CLEARANCE A w n L R G E H ....SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE -- AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-02-00 Air Clearances . � RAGs. WALL �� § (o } CD § %� � 9@ � �/ �3 �2 ° Sm CIO� / C 2 04% 2 @ co E E 64c) of � ( 2 L- 04 % 621 ) �§ — \q (D — � � CD m 2 E cp E E M. _ %% § E Co z § 7 k �� � f q 2 ) 00 ( U 04q \ E \ C%4 @ E § LUCD LO �� � ) m ; w # ± r (00 00r g \ V N%ƒ LO k \ �m w2 ¥ ; O E � Z $ INTEGRATED HOME COMFORF --0- Air Wiring Diagram/Application Guidelines "a RA13 Series Control Miring FIGURE 2 `IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(W/BK)AND W2(W/BL)BE JUMPERED TOGETHER. TYPIC7THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT E FOR TYPICAL ELECTRIC HEAT SUBBASE rYJ Y, I$;i OR -BROWN WIRE YL -YELLOW WIRE OR-BROWN WIRE -.. p X -WIRE CONNECTION R-RED WIRE .. YL-YELLOW WIRE w. W/BK-WHITE WIRE WITH BLACK STRIPE G/BK-GREEN WIRE WITH BLACK STRIPE ----.....--- - PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION -m TYPICAL OAS 0"R TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX * x W/BL TYPICAL CONDENSING M R TYPICAL CONDENSING -R' UNIT * W/BK UNIT W� G/B K Y.. YL. —YL YL www ?4 .- PU Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in.wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55T(12.8'C). 3. Maximum outdoor operating air temperature is 125°F(51.7°C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory—supplied filter drier must be installed. Air Refrigerant Line Size Information D RA13 Series rCfJ 00 00 "� O O cD cD toMCI, MII - � '.CD CD rn rn /, M O O Cn c) rn l Oo) rn rn O c o o C) C) c o l C) c c c CD R - MNNM0W00 � O I� pp 00C0CN CO CD M a0 M � cD � r � V f Lf) W U-) � co co 00 00 O m cD O O O T T O O O O I O �. O O O O / Cj O J p C=; 0 0 C Ci CCD IL _ _ d C M C CD M l!7 N M co N n C cc O G O G N ti O �',V O CO cD r % cc C d CD 00 N N f� ti ( cD cD Com) 00 O O n .� c O OH O) O O �.. O O) O e O O O r O C O O O O O O O O � O O O 0D r g 00 O 00 O M rD lf) M lfI CD N O N O O O r O O [ LO O Lf) O N 00 F- LO Ln , Ln d CDco O M M W W O O cD CD 11') 00 O N CN) f- 6~7 r La rn rn O rn O o) c) rn m rn rn O rn O r v o O o C) c o 0 0 o O 'co ci o , c '� o c r - ' - - - 4 � 117 '�' M O M O 00 W M O cD O 00 O W O lc') O lA O r .-. 00 00 O CD O CO O M O M O � f� C �',,� � cD � CD � � r 1 O � r- O O V W 00 r- P cD co O O O O V 00 W d YC9 C O O O O Of O O O) Q) O O I O O O O O O Cn OI O � C C O O O C O O �F O \O O O O C) fi O O C O O O O O C CO O a0 O O T O o0 W V Lp R O L2 7 O N O N O �... C LO co O LO M !C§, l cc O cD O V O V O 00 O 00 O r O O 00 y J cc C Ln «� r r- m O Q) ' r1] l/7 00 a0 M M 00 00 O O ti � r- O QI O) l() O Q) O7 N C O O O O ' O O O O O O O O D) O C'1 O O O 0) Im O Q) A r O O O O O O O O O O O O O O O O O O O O O O O O O 7 � � co 7 co C) C-) V M n 00 f� O W O 00 N O N O N O O O O O O W r 7 N O N O r t` t` ll] O lA O M 00 M ap M o0 CO c0 r J r r r r r r y C C oo m O O cD O �j 00 00 N N 00 M O O OOi O CO) N O O O O M O o) M D) O Q1 C) QO) O O M C O O O O O O i O O i O O O O O O O O O O O O CS O c O O O n o c c ' c c c o O (D c W M W M a0 ti O O O O L; O ll') 00 00 ca V O O Nr O O 00 O 00 O ti "O O O -q- CD O O O W O W O C Z O ' c W 00 00 O O O r- r- r- cn O '....Q) cD co O O � M 00 00 O O O r` O O E rn O O Cn O O rn rn rn rn rn o) o) o) O C', (n O rn rn O o o C� rn 0 0,crn i c c C=) cD cm c c c C" E o cp LO x N 117 ll7 N u7 u7 u'] lL) In lf) m In Lf! m w ''...V-) T LD LO T LO U) Ln M UO LO o H co r- 1-- CD r- r- N l r- N f� O '...ti co rl- l co ti r- n r- � l on A y a 01 � C 0 0 0 0 00 W W W O O O M M O O r- ' 0 0 0 0 0 0 CD W O O y FOS C O O O O O O O O O O O O O O O O O O O O O O O O O O CR O N T O O O r r r O O O r O O O O O O O O O r r O O r a cr W c0 o Y.1 N O O O O O O O O O O O O O O O O O O O O O O O O O O O O c y Lo Lo LO � LO rn LO LO LO LO LO u') Lo to LO LO LO Lo Lo Lo LO LO U.) LO LO Lo M U.) o E c E a U O M O O O O O O O O O O O O O O O O O O O O O O O O o) O O O m m 9 r O 0 0 0 0 0 0 0 0 0 0 0 0 O O O O 0 0 0 0 0 0 0 0 O CI O O o N O O O O O O O O O > V LO M LO lf) Lf) LO Lf) LO O � � Lf) LO LO LO LO LO In Lf) lf) LO lf) lCJ lf] lf) to lf) lfJ O y N N N N N N N N N N N N N N N N N N '..N N N N N N N N N N E N n U C ,y L O N O 3 U rn J O p C c0 LL ,.;a y c:a J= y v p7 O6 J d 3 Q Q oD Q Q O Q M N Q - N Q N M N Q co Q a0 Q 00 O C ? p.� mo c+! � — n � � r � r � .� rm? � '� r � �'C � O11 , Cw F- r oo �o > J'- �+-y r Z Z r Z Z r Z N r Z N r Z r N r Z r Z r Z r r r y �+d W CIO Q c a m �' Q10 C= a Y O 'p J y ti rn d }� co o n cc y — EC N E o ,c E a W W 00 V 7 R 00 W W 00 00 R W W Z CO 00 G«y O M L[) co M M '..LO LO U7 M M co LO U) M M LO In M M M n M co n C p R 0 _ o c a a a N C -!EME co o cLY J 7 N r W WV\ 00 r O\O r CO 00 r 0\O r 00 N OD N ;0 N -c�0 CV Li') M M M M M M M ll'Y M M CO M M ll'Y M M M t? 'moo y caaa c NcLUx MM W W o o C C C rY Z N CV M co W o . CLa INTEGRATED HOME COMTCF�-111 13 '), Air Refrigerant Line Size Information "0 RA13 Series NO C ` C) O to N J M f 000 000 i l N ,,I r lA tf) M O) 0 O) O) O) N a O Ci y O % O O I�J (0 M N I N J N J�I I N () /f I (n �''0 O •G i 0 I ( ai 0 N p O O O T z. fCL 0 (0 V 0 0 r 10 O) 0 O) O] 0 0 lr0 s (0 C O CD. y r W ti .0 p �fl'I i d O N d ll'! p N 0 r 0 / cm 0 0 T O) 0 / I, O) QJ C O Oto \ O CDI. C O CS O rL+ N O O JJ \ O \ O 01 T U-3 O LO O �! J M O M O C l d d J m f0 d N C T M M a T d co 0 T � r O C O C O C O C p C Cl r \ \ \ \ •� O O \ O O \ O \ O O O' r 7 f0 O c0 O V'O O W 7 O In Ln 00 O N N r\ ^ O O H O N 0 0 0 0 O) 0 0 0 O O C O O O C�, O C:l C O T O \ O O \ O 'O r Ca ^ p r O O O O V _ E to M M v v 00 00 p p ua rn rn rn rn a! rn rn o 0 r O O Ci C O C C O r r — a CO r \ \ \ \ \ \ \ \ \ \ O 3 Lp )OLn LO Ln In M Ln Ln Ln Lf) LO ` o c6 a OI C 00 00 Q) M r- r- 0 0 fA O 0 0 O) Q) M M O) 0 0 O a L? O O O O O O O O ca v YJ {O \ y \ \ \ \ \ \ \ \ \ o � N O O O O O O O O O O COD Ln Ln M Ln Ln Ln In Ln Ln M OO E r O C1 0 0 O O 6) 0 O C=> U O_ r In Q) (,) O O 0 N v N N N N N N N N N N E A N L d U = � L O co Ox) H H N J O d OC. C O � J C �N � Q p w N O M v Go cm W O) 00 y o � o f C J._ T r r r r r M r M r M t3 a duxiCL m �i amt o �► m� �0 3 d 7 J yM Ai `i cc E J H a E L m e a r E Y E O a—j � co co o +? o � E = 1O N v v o\o -c\o v v --00 m g p y co M I` ti co M r7 7c o g _ O O C N CID Q y m o v c y dy GD c r o aL s J 3'=Z! 00 N -o\O CV C10 cV -0\O CV -0\O CV c =o c c p O y Cl) CO Cl) CO M R L = W d IV = O O C C C y + UU Ln N = � Q O_ CC �n Air Refrigerant Line Size Information 0 RA13 Series R a0 C', M ,� (, O cD m m O O m m O m m m m m m O m t` O O O O O O O O I O O O O O i 9' j 0 O C', C o o r— v m o m o M o N M N CO N N N I M M M 1 U') l() 00 00 n r- (1'J M M 00 00 O O - O CSI O m m m f T I O m r. O O C) O) 0) O O 0) 0) O 0 0 n 0 0 0 0 J O O Cj O I O O O O O O O O to Jcli N O N O 00 � (0 (f) O O O O O m O I, N co N M r N J r N I� N N M / N M M M 1 I d � (0 (O co CD N N t` f� 'R W W f� Q J m m { m m 0) 0) m m 0] M Q1 O) O) 6) Q) o co o o o O o c ci o 0 0 0 0 C. 0 0_ O O (D m (D m " O N O N O O O g N co 3 N M I N N coM N N M N M CO CO CL.R co co [ O) m M M Oo 00 O O (O co m LO w 00 N N M M P 0) m m m m m 0) 0) � m 0) m m O m Q) O m m Ifs V O O f 0 O O O O O O O O O O O i O O O O O O - l / - - r � D • f (l') O ! u') O I m O O O ti � O O O O N M N M CO M N N N M j N M N M N M C y � 0G 0G m m m m m M 9 O O C O O r O O O O O O O O � O O O O O O O O 0) C f' M 3 O O O O Lr] m (7 m (O O \ (O O N O N O O N N M N N M N M N Cl) N N N CVD N M N M N M OI cp) 0) m J _ C OO C r- m � � I � T � � � � � M T T m m m T T T T N ('9 O O O O O O r' O O O O O O O O O O O O O O O O O O O O � � M M O 00 O M O M O 00 O W O O O O O O C O V C:, N M ^ N co N M N M M M N N M N M N co N M cr W 7 E. 0 y O) a0 DD ao m m m O (O m m V Vcg� oocy� W N N W W W m m m (0 CO m m C O O O O O O CO O - "I O O O O O O O O O O O O O O O O O O .O N W M O O M O O O f O O \ O l() m l(') O O lf) m O O n O w M M M M N Cl) IJ N M N M N M N N M N M N M N M o_ E! C Z %, a V > 00 00 00 0) m m r- r- m m (O (O m m � w W m O O O ti r— m 0) M E m m m m m m rn m m m m m m m m m rn m m o 0 o m rn m m C N ' 0 0 0 0 0 0 0 0 O Ci 0 0 0 0 0 0 0 C) 0 O O o o tO �, E C5 3 l01 T K m M M O M M M M M M M M M M O M O M M O M M M M M M �' O h M N N N N O N N O N N N N N N N N N N N N N N N N N N _ R d O � O � C m m m O O O 00 w W O O O W 00 m m r- r- m m m O O O 00 co O O C40 m m m O O O m m m O O O m m m m m m m m m O O O m m O O a cc C—=, O O r O O O r r r O O O O O O O O O r OLU c6 O y� lf) L() lf) l(') l(7 l(7 l('Y l(') l(') Lf) l() (1'Y '....LfI lf) lf) l2') l!') t(') LO L(') (1'7 l() In 117 l{7 l!') l(') N') > "O N E to T E U O M O O O O O O m m m O O O m m O O m m O O O O O O m m O O T O O O O O O m m m O O O m m O O m m O O O O O O m m O O _ v O O O O O O O O O o `� 00 CD00CD N d � Cl U C L O 07 c D C d o � rn rA O C o O E L O] C O O A H g J a C J � 4 cZ � CC 33 ZQ u � � � � �Z Z ZIf! CT M Z M r Z M K �!.d W m D Q 0 +' O d�OIC � y N aKi O o T mN � E L d o eo eo ao cv v oo eo 00 v c v o0 00 v v o0 00 v � v co w oo v � oo o0 0 � E�E sF J C 117 l[) lf] M co_ co U.) (n (n M_ M M_ In ({) M M n (f) M_ M_ M C7 co O Oyu DO 00 00 lf) l(7 lf) 00 a0 00 I!') l(7 lC) 00 00 In L(7 00 W l(') ''...l(') lf) M M M lf] lf) M M 00 W 00 O O O o0 00 00 O O O W W O O M M O O O N N N O O N N A` a E lf) lf] lf) m m m L() lf) t17 m m lf) lfJ Qi Q1 l() t(] m m m N N N m m N Cj N -O E chi N rn � = d m a y No � R �tiN ="aa 00 (O 00 O (O 00 N CO CO n 00 N 00 N c = o+a T - — — T - T T •L� J y C M M M M M m M M co J O 7 w E (f) 7 M Lo V M Ln V M (n V M � M � M v M � M r� r M u co M a� -.- }/ O' E M m � M m (P) M m (P) M m LQ m (f) m LQ m (f) m U! N m � N Lf) N (f) N E E is'o-o a J CO ti m (0 r- m co r- m (0 � m r- m r- m r- m r- 0) ti m m r m r m N a a R v t E c c ~ O W M C O C 0 ¢xi EEM ? 0 0 COD Y F-N I- Y r Y~ (O H M~ O CO(f)# p O W(17 m C O LO;• 00cc u co N u w o o 3 a a CID Z o o ------------ 2 r N c7 Q c D Air Refrigerant Line Size Information a RA13 Series LO 00 r � 1 0 0 '� � �� o � o o n / M I1 N N Ln � rn rn rn rn CV i I' ,� O I ',� I 1.O i0 fco 0 Cl) N N d •d �', 60'1 � 6-) 601 f 07 O O O 0 ( O I Q) i 61 M N N M M CLI 01 6) QOi OOi T OMi lO v O O O O - O CD rL * O C O Liz 0 0 0 .--. M M Cl) M .0 y � of 6) M 6] O TC) 61 61 T 0 0 0 0 O O O O L S O Oo o 0 0 0 0 I M M I, M M C y d m J _ C O •c OM1 M M co M 61 C1 T 60i M O O M O O O O O O O L-j O O M M O O 7 N M N M M M M LS W � O - yM LA 0o a0 N N O O O h O? 61 61 O O? Q1 O) O O O C M 2 O O O O 0 O CJ CD .o •y0 N iO O V O O O fA O O O 9 2 N M N M M M M o � n V 7 L6 c6 rn rn v v oo ao 0 0 Q as N . rn . rn rn rn rn rn o 0 N O O O O O O O O m a a "6E 3 W T' •� MM M o C? g N N N C-4N N N N N N 2 ? o c 00 00 Ern 01r- ti M M H LO d? 61 M O1 61 61 O) O O O a cr T O O O O O O O O R LU LMLn V) Ln Ln Ln Ln y E r E a H o r 61 Ch O O 6� T O O O O fO L L L1 U � � O •D 3 cmc = rn rn � yLv 0 -E o` o r m c o O /\ RF•rL =a a c 4-9 J d y m O p•r d 3. C* O CO O N -e N -�r N N J•- �H( p T T N et N N T N T N T U (� 7.y W d �/ d C L!O •� o rn 3 cc Q•��C � w�"' aKi C 9 c 3 m e o>a o O o �• o - H Eo a�-E E c L d o v v m v v o ?'E:E co n r- M c � C - � o � E Y� Lac N O• r r c a a o 3 0•- Ln Ln M M Ln Ln M M O y y E O O N N O O N Cl! 0000 - ea E CA Cn N N cn CA N N LQ Lq Q y N N N N N N c Q c ct°i N N O m C R {gyp J N u M_ M M M_ Lh i J p (y E Cl) I� M I� M r` M � M >= c c 4-6Q cr E 61 N T N Lq N CA LQ N Uicc N O c m a a (O a L L L a a�a1 Y H Ln Nm E m � c c C E 3.2 O O L(1 H R A •C u rLc) W O Q C Q CD O O Q Q Q INTEGRATED Z�NC7v uiO HOOVPORT --Oej Air I Performance Data RA13 Series Performance Data @ AHRI Standard Conditions — Cooling Designated Tested Combination(DTC) Outdoor Unit Indoor Coil Total Capacity Net Sensible Net Latent BTU/H[kW] BTU/H[kW] BTU/H[kW] SEER EER Indoor CFM RA1318 RCF2417STA17600 [5,2] 12600 [3,7] 5000[1.5] 13.00 11.00 1L/sI RA1324 RCF2417STA 17500 I's 11 7000[2.1] 1— 600[2812) -17 6] RA1330 RCF36175TA 28400 11.00 800 f3 - -------- 21000 [6.2] 7400[2.2] 13.00 110.1] .00 RA1336 RCF3617STA 1000[471.9] 23400 [6<91 11200[3,3] 13.00 11.00 102 [483.7] RA1342 RCF4821STA A0500[11 u9] -- RA1348 RCF4821STA 28700 [8.4] 11800[3.5] 13.00 11.00 140 [660.7] 47500[13'9] 34000[10.0] RA1360 RCF6�024STA 56000 rig,41 Note:Additional ratings and system match ups can be accessed on MyRheem.corn at: Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website:www.ahridirectory.org [ ]Designates Metric Conversions SUMMON— Air Guide Specifications a I RA13 Series GUIDE SPECIFICATIONS General AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER System Description RA13 Outdoor-mounted, air-cooled, split-system air conditioner com- 1-1/2 TO 5 NOMINAL TONS posite base pan unit suitable for ground or rooftop installation. Fans Unit consists of a hermetic compressor, an air-cooled coil, pro- — Condenser fan will be direct-drive propeller type, discharging peller-type condenser fan, suction and legend line service valve, air upward. and a control box. Unit will discharge supply air upward as shown — Condenser fan motors will be totally enclosed, 1-phase type on contract drawings. Unit will be used in a refrigeration circuit to with class B insulation and permanently lubricated bearings. match up to a coil unit. Shafts will be corrosion resistant. Quality Assurance — Fan blades will be statically and dynamically balanced. — Unit will be rated in accordance with the latest edition of AHRI — Condenser fan openings will be equipped with coated steel Standard 210. wire safety guards. — Unit will be certified for capacity and efficiency, and listed in Compressor the latest AHRI directory. — Compressor will be hermetically sealed. — Unit construction will comply with latest edition of ANSI/ — Compressor will be mounted on rubber vibration isolators. ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and Condenser Coil will carry the UL label of approval. Unit will have c-UL-us — Condenser coil will be air cooled. approval. — Coil will be constructed of aluminum fins mechanically bonded — Unit cabinet will be capable of withstanding ASTM 13117 1000- to copper tubes. hr salt spray test. Refrigeration Com onents — Air-cooled condenser coils will be leak tested at 150 psig and — Refrigeration circuit components will include liquid-line shutoff pressure tested at 550 psig. valve with sweat connections, vapor-line shutoff valve with — Unit constructed in IS09001 approved facility. sweat connections, system charge of R-410A refrigerant, and Delivery,Storage,and Handling compressor oil. — Unit will be shipped as single package only and is stored and — Unit will be equipped with filter drier for R-41 OA refrigerant for handled per unit manufacturer's recommendations. field installation. Warranty(for inclusion by specifying engineer) — U.S. and Operating Characteristics Canada only. — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption Products at full load will not exceed .. kW. Equipment — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at Factory assembled, single piece, air-cooled air conditioner unit. conditions of CFM entering air temperature at the evap- Contained within the unit enclosure is all factory wiring, piping, orator at °F/°C wet bulb and °F/°C dry bulb, and controls,compressor, refrigerant charge R-410A, and special fea- air entering the unit at °F/°C. tures required prior to field start-up. — The system will have a SEER of Btuh/watt or greater at Unit Cabinet DOE conditions. — Unit cabinet will be constructed of galvanized steel, bonder- Electrical Requirements ized, and coated with a powder coat paint. — Nominal unit electrical characteristics will be v, single —All units constructed with louver coil protection and corner post. phase,60 hz.The unit will be capable of satisfactory operation Louver can be removed by removing one fastener per louver within voltage limits of v to V. panel. — Nominal unit electrical characteristics will be v, three phase,60 hz.The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. INTEGRATED18 H01AE Air Limited Warranty a RA13 Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required)..... ..............Ten(10)Years period stated, in accordance with the terms of the limited warranty. 'For complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. The new degree of comfort:" In keeping with its policy of progress p .. ..... ....r ... eap continuous r ress and product improvement,Rheem reserves theright to make changes without nonce 9 po cY Rheem Heating,Cooling R Water Heating • 5600 Old Greenwood Road Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72908 • www.rheern.com Brampton,Ontario • L6Y OP5 PRINTED IN U.S.A.6/19 QG FORM NO.A11-221 REV.8