Loading...
HomeMy WebLinkAbout47739-Z TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY ,ru BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 47739 Date: 4/26/2022 Permission is hereby granted to: Reilly, Brenda —.......... . ..................... _www................. www. ................. 905 Stevens Ave wwwwwwwww__.. Westfield, NJ 07090 .............. ....... To: install generator as applied for. At premises located at: 510 Harborview Ave., Mattituck SCTM # 473889 Sec/Block/Lot# 100.4-42 __....... __ �._ .. _www._....._....... Pursuant to application dated 3/23/2022 and approved by the Building Inspector. To expire on 10/26/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total;. � _ $235.00 Bui)ingin;:spector TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 ' Telephone 631 765-1802 Fax 631 765-9502tt -L/vv wyy.s tk.1 Edto v'n o Date Received APPLICATION FOR BUILDING PE MIT For Office Use Only PERMIT N0.--��13 BuildingInspector: ......... _ MAR 2 R 2022 Applications and forms must be filled out in their entirety. Incomplete BUILMNG DEP-r,' applications will not be accepted. Where the Applicant is not the owner,an T ?^J OF SOU"i"HOLD Owner's Authorization form(Page 2)shall be completed. Date:1/12/2022 OWNER(S)OF PROPERTY: Name:Sean Reilly SCTM# 1000- 100-1-42 Project Address:510 Harbor View Avenue, Mattituck, NY 11952 Phone#:862-308-4718 I Email:reillyfrancissean@gmail.com Mailing Address:905 Stevens Avenue, Westfield, NJ 07090 CONTACT PERSON: Name:Ed Reiff/ Gen Ready Mailing Address:128 Pulaski Road, Kings Park, NY 11754 Phone#:631-544-0400 Email:office@getgenready.com DESIGN PROFESSIONAL INFORMATION: Name:N/A Mailing Address:N/A Phone#:N/A Email:N/A CONTRACTOR INFORMATION: Name:Ed Reiff/ Gen Ready Mailing Address: 128 Pulaski Road, Kings Park, NY 11754 Phone#: 631-544-0400 Email:office@getgenready.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 1i1 Other 22kw natural gas generator installation. $10,050.00 Will the lot be re-graded? ❑Yes I*No Will excess fill be removed from premises? ❑Yes BNo 1 PROPERTY INFORMATION Existing use of property:Residence Intended use of property: Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes *No IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name):Ed Reiff / Gen Ready @Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF Ed Reiff / Gen Ready being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the Contractor/Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 0./`C 20 Notary P lic PROPERTY OWNERZ ION (Where the applicant is not the owner) Sean Reilly residing at 510 Harbor View Avenue Mattituck, NY 11952 hereby authorize Ed Reiff / Gen Ready to apply on my behalf to t Tow f o d Building Department for approval as described herein. , / Owner's Signature Rosemary FaielUate Sean Reilly NOTARY PUBLiC,STATE OF NEW YORK Registration No.0lFA4901831 Qualified in Suffolk County Print Owner's Name Commission Expires July 27.'_0'l.`} 2 � � BUILDING DEPARTMENT-Electrical Ije��Jr r TOWN OF SOUTHOLCD 2 fl M Town Fall Annex - 54375 Main Road - PO Boa ,Ir � yX Southold, New York 11971-0959 0� 10401 Telephone (631) 78 -1802 . F (031) 795-95102 ro err southoldtownn . oar - seandsoutholdtownn ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1/12/2022 Company Name: Gen Ready Name: Ed Reiff License No.: ME-2740 email: office@getgenready.com Phone No: 631-544-0400 01 request an email copy of Certificate of Compliance Address.: 128 Pulaski Road, Kings Park, NY 11754 JOB SITE INFORMATION (All Information Required) Name: Sean Reilly Address: 510 Harbor View Avenue, Mattituck, NY 11952 Cross Street: Reeve Road Phone No.: 862-308-4718 BIdg.Permit#: email: office@getgenready.com Tax Map District: 1000 Section: 100 Block: 1 Lot: 42 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Install a 22kw natural gas generator. Check All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES [ZINO Issued On Temp Inform at` (All information required) Service Size 1 Ph 3 Ph Size: c; 2 A # Meters Old Meter# Mdv RdcphDd Rd Qdbnrrndbs T rrcdc#qtt rrc N udcgd' c Underground Laterals 1 2 rame Pole Work done on Service? N H F Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xisx Mr. Faucet Service Co., Inc. InstallGas.com 201 Northwest Dr. Farmingdale, NY 11735 Sean Reilly 510 Harbor View Ave Maftituck NY 11952 190 6t. TAN GENERATOR 4 f til M I:) 111, LUI 1 vlr lir E11?1.(1(1% III:IUII'I' .•u ��, en!�n,�r u.r rr wen 171 I11 11:11 I I I'l l'h TOWN 01 SOUTHOLD SUFFOLK COUNTY', NEW YORK ,C 'At No 1000-100-01-47 SO,[ 1-30 HOVLDaUI 17 2015 n fat u�� rN rn 40 �.r i i f_ p� e eti u� r Q a, Nathan Taft Corwin III Land Surveyor DATE(MMIDD/YYYY) �. CERTIFICATE OF LIABILITY INSURANCE F 04/20/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CaDt1 G' PRODUCER ym6rCT ...........www.......... ... ......... ........,...,_._ FARM FAMILY CASUALTY PHONE o w __ _ __wwwwww......w__...... 859 CONNETQUOT AVENUE d (L ; ISLIP TERRACE,NY 11752 INSURER(S)AFFORDING COVERAGE NAIL# 631-277-7770 INSURERA:mmFARM FAMILY CASUALTY INS.CO. 13803 wwwwwww .wwwwww.........._._.............. INSURED INSURER B: STATE INSURANCE FUND 36102 GENREADY, INC. Inlsuac SHELTER POINT 81434 128 PULASKI ROAD INSURER D: KINGS PARK NY 11754 lom„ F .......... _w INSURER F: COVERAGES CERTIFICATE NUMBER: 125539 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR A S BR POLICY EFF POLICY EXP LIMITS .„,.; .... ..._....._. w..........w__www.............. 9 POLICY NUMBER �,;II„A,IXYYY ..(MMIDDIYYYY LTR TYPE OF INSURANCE p�q p'I' ,,,,,,, A X COMMERCIAL GENERAL LIABILITY 3152X1390 05/07/21 05/07/22 EACH OCCURRENCE_ $ 2,.000,000_ CLAIMS-MADE �X OCCUR RSMI (Caaa acesa $ 100,000 MED_EXP(An one person) $ 5000 PERSONAL&ADV INJURY GEN'LAGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $ 4,000,000 nGrHER PoU, 0ape FILOC PRODUCTS-COMP/OP AGG $�4000000 ': $ AUTOMOBILE LIABILITY A 3152C4335 _ 05/07/21 05/07/22 a:eantii $ 1,000,000 ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS X AUTOS BODILY INJURY(Per accident) $ UTO X HIRED AUTOS X L AUTOS (,Pai" crcdsra') $ �NNNUMBRELLA LIAB 3101E1933 06/03/21 06/03/22 EACH OCCURRENCE $ 1,000,000 EXCESS LIAB AGGREGATE ... $ 1,000,000 DED X RETENTION$$10,000 wwww. $ �.. WORKERS COMPENSATION .DTH;_—_ww__. B AND EMPLOYERS'LIABILITY Y/N CERTIFICATE 'a�-Z'AT, T."— ""'-' ANY PROPRIETOR/PARTNER/EXECUTIVE """"") 11A ATTACHED E.L.,EACH ACCIDENT $ '.....MFandatory in NHS EXCLUDED? I,,._._.,.f 1 046 681-1 E.L.DISEASE-EA EMPLOYEE.. $ If as,describe under GRIPTI NQw,OF OPTIQN1,,.RAbel ay✓ E.L.DISEASE- LIMIT $ DES C NYSDBL DBL 265291 01/01/07 INDEFINITE STATUTORY DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required)._ �_ww.._... CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE TOWN OF SOUTHOLD THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 54375 MAIN ROAD ACCORDANCE WITH THE POLICY PROVISIONS. SOUTHOLD, NY 11971 AUTHORIZED REPRESENTATIVE 1988-2014 ACORD C RP RATI N. All rig is reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD NYSIF New York State Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE, NEW YORK 11747-3129 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) 91A AAAAAA 112763133 VINCENT C DALEY 859 CONN ETQUOT AVE ISLIP TERRACE NY 11752 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER GENREADY INC TOWN OF SOUTHOLD 128 PULASKI ROAD 54375 MAIN ROAD KING PARK NY 11754 SOUTHHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 11046681-1 494738 05/20/2021 TO 05/20/2022 5/4/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 1046681-1, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT EDWARD S REIFF VICE PRESIDENT ANDREW J REIFF OF GEN READY INC-A TWO-PERSON CORP. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 167265012 U-26.3 EW YORK Workers' CERTIFICATE OF INSURANCE COVERAGE TA7.� Compensation Board NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by NYS disability and Paid Family Leave benefits carrier or licensed insurance agent of that carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured GENREADY, INC. 631-544-0400 128 PULASKI ROAD KINGS PARK,NY 11754 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to certain locations in New York State,i.e.,Wrap-Up Policy) 112763133 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b.Policy Number of Entity Listed in Box"1a" SOUTHOLD, NY 11971 DBL265291 3c.Policy effective period 01/01/2022 to 12/31/2022 4. Policy provides the following benefits: © A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ❑X A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. rl B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described abov��f e.. Date Signed 1/6/2022 By UJI, (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be emailed to PAU@wcb.ny.gov or it can be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board (only if Box 413,4C or 56 have been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law(Article 9 of the Workers'Compensation Law)with respect to all of their employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.Insurance brokers are NOT authorized to issue this form. DB-120.1 (12-21) 111111111111111111111111111111 11111 Suffolk County Dept. of Labor, Licensing & Consumer Affairs MASTER ELECTRICAL LICENSE Name EDWARD S REIFF Business dame 3� This certifies that the GENREADY, INC. bearer is duly licensed by the County of suffolk License dumber: ME-2740 Rosalie Drago Issued: 0510111980 Commissioner Expires: 05/01/2022 �oozll -� . GENERAC 2214 � GUARDIAN SERIES 20 Residential Standby Generators Air-Cooled as G Engine g rt INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz E True Power"Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209-0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz s Two-line multilingual digital LCD Evolution" controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available M Electronic governor �a����e✓� 0 Standard Wi-Fig connectivity 0 System status&maintenance interval LED indicators • Sound attenuated enclosure ' ♦ Flexible fuel line connector r wh Natural gas or LP gas operation E 5 Year limited warranty y r Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.' Must be located away from doors windows,and fresh air intakes and in accordance with local codes 0 P t� ra ;� �w r¢rr2/Irbrary l)rte,r„tcratrdffr"eCed2'�adr�a;tel � or C IIIM����� u9 LJ t~w feel e,ie,;trrl rP ^iy(? C 204 "rr204.01 0I F'eMr+�.pdf c LISTED %W&CF%Or CUL oertrfication only applies to unNnctad units and units packaged wt WRr t^d er cW s0ches.Units packaged w4h the Smart Switch are ETL or UL uel&ed do tetra iUSA only. FEATURES • INNOVATIVE ENGINE DESIGN A RIGOROUS TESTING are at the heart of Gen- 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- stale-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions, loads to the engine.Digital voltage regulation at±1%. CC TRUE POWER'”ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave 0 SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. • TEST CRITERIA: 0 GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with * PROTOTYPE TESTED v HEMA MG1-22 EVALUATION GENERAL POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility, O MOBILE LI IID CONNECTIVITY:FREE with select Guardian Series Home standby O PRVIEW'" TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators, Mobile Link WI-Fi allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power,The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator.Included with model G007210-0. w G E N E R A C GENERAC PROMISE "" PAWN RIM ,� "O'EN 'BRAC' 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to:t1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch(if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution—Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed.raised buttons Smooth,weather-resistant user interface for programming and operations, • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,BO%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. G E N E RAC mmommomm 20/22/24 kW Features and Benefits Unit _ • SAE weather protective enclosure Sotnd attenuated enclosures ensure quiet operaftlon and protection against mother nature,withstanding winds up to 156 mph(241 knVh).H6nged key locking roof panel for security,LAI-out front for easy access to atl routine maintenance items.Dedrostatically applied textured epoxy paint for added durability, • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 16 in(457 mm)away from a structure. Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21,75/CSA 6,27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NEPA 54 installation requirements. Connectivity(WI-Fl equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. it Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. CL03ENERAC manommumm 20/22/24 kW Specifications Generator Model G007038-1 G007042-2 G0070BB-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G00704M G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) ,Hated marJrnin continuous poyrmr capacity(LP), 20,000 Walls' 22,000 Wafts" 20,000 Wan' 22,000 Walls` 24,000 Watts' Rated maximum cononaous power capacity(NG) 18,000 Watts' 19,500 Watts' 18,000 Watts' 19,500 Watts' 21,000 Waits' Rated yoltage 240 Rated maximum continuous load current-240 volts(LP/NG) 83.3/75.0 91.7/81.3 83.3175.0 91,7/81.3 100/875 To w,*mxpc mtomon ° Less than 596 Ma= r=c QCs.cream' 90 amp 100amp 90 amp 100amp 100amp ?hil 1 c Cr ales 2 60 Hz Rated AC wear q 1.0 -ca xMC 5a6ery requrem�lt(trot included) 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum he u-t(ID" "g, 448/203 466/211 436/198 445/202 455/206 Dimensions,(L z W Y H)in/cm 48 x 25 x 29/121.9 x 63,5 x 73.7 c, ti n c?tA)at 23 ft(7 m)mm generator operating at normal load" 67 67 67 67 67 Sountl;a'put in,dB(A)at"23,ft(7"m)witn;generator in Oulet-Test"low-speed exercise mode" 55 57 55 57 57 xa c;se ­rauon 5 min Engine ,yne GENERAC G-Force 1000 Series Wurrlber d;cyuders 2 ,a r 999 cc �� Alblocituminum w1 cast iron sleeve Cyi,,a a nate,, Overhead valve � Solid-state w/magneto IPW�0 Electronic sys:eT Cprtruressr4n rdti4 9.5:1 12 VOC 0(t capeaa�,mctutbrg.hlter, Approx,1.9 of/1.8 L 3,500 " ft3/hr OWN) 204(5.78) 228(6.46) 164(4.64) 203(5.75) 1/2 Load 301(8,52) 327(9.26) 287(8.13) 306(8.66) Full Load propam Ra/hr(go 87(2.37)[8.991 92(2.53)[9.57] 86(2.36)[8.95) 92(2.53)[9.57) p 130(3.56)[13.48] 142(3.90)[14.77] 136(3.74)[14.151 142(3.90)[14.771 rvee Fuel pipe must be sked faz lull load.Rapoteo @ p es a e to naaaCcr Elie,annet at I, d range$-3°5-7 in inter dor Na,10_12 inwareicoWrrrn(2.4-2,99kFtt for LP s 2500 Lor or hath w t& b NG°l oa Lh a �iie cordent,nAtO I nr"Fitt x 93,t 5 LP)W rnW x 37 26 Controls Ta n a�t x m nguel LCC Simple user interface for ease of operation. Mode buttons:=AUTO Aulomahc start on utility failure,Weekly,Bi-weekly,or Monthly selectable exerciser. a;uA: Stan with starter control,unit stays on.If utility fails,transfer to load lakes place. OFF` Stops unit.Power is removed,Control and charger still operate, messages Standard Ergrre;tun hn Orocation Standard 09arurable start ae'ay between 2-1500 seconds Standard(programmable by dealer only) Ubldy Yollage lcss/Retrxn to Util"ty adjustable,(brownoul setting)m From 140-171 V 1190-216 V e Sc,Capao a Exe•aser/xe•cise Set Error warning Standard itrrl/AWTrVMmrrter¢ice togs 50 events each Erg car,seq ce Cyclic cranking:16 sec on,7 rest(90 sac maximum duration), S"oOt, Starter cannot re-engage unfit 5 sec after engine has stopped. S-arr,Be­y Crarger Standard Standard -c ey eo em,,Protect ,on and Battey Condition indication Standard Autonsrbc image ftegtdetron with Oyu and,under,Vonage Protection Standard e4Ler,rylO+erinatl 5iepper Overcurreru Protection Standard Safely;used/Fuse"probiemProtection - Standard A,GMAC LOW Oil Pressure/ igh Oil Temperature Shutdown Standard Overr7any/Oyerspeed(0172 Hzyrpm Sense Loss Shutdown, Standard ,g•Engre Te peiature Shutdowd Standard uaerral Faum ncorred Willing protection Standard ext Ccrn,mon ernal cult capability Standard Fuad Fmnware g � Standard co l ad a e a+a cm"r,fv +o"c cr o e" 4t n ScV4 em MKV f°4m Wle slices ct¢4 0enandur rmy De rant asperang on onstatkakon par rmlem,ft,ng,definitions-Stand*App 4rable for suppHyirq em gr cA Cowav ora o sr r/r.,°a ar.,7 p nwa a 7dge No overload cap vhly 3 ava,+adw for tries rasing,(APP nrt cgs iia accordance with 855514,6'SOM acid 0fT Z11). W019LM ltho Ml dams and cuirond ata dubs o ars(nom d/s , ,,ras as rc BTUJo ve c ire,amort awpeau c°awe �g tie pad arwS cera oro„ado Mdarvum poror d rsapprriraatar y 3.5 each 1,0W k( a.B m)above sea ;ave.roa'SOAll rdecrease a^;^,Tamarw.A;y1%rzaean10°F(6C)atove60 IFF tn61C). Cos'Em N E R A C' ====mom 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007039.1,G007039-3(20 W) 0007043-2.G007043-3(22 kW) • Intel I igently manages up to four air conditioner loads with no additional hardware. No.of poles 2 • Up to eight add1lonal large(240 VAC)loads can be managed when used in conjunction Current eating(amps) 200 with Smart Management Modules(SMMs). Voltage rating(VAC) 120/240.10 • Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor(fixed)' • Rated for all classes of load,100% -Pick-up 80%equipment rated,both inductive and resistive, -Dropout 65% • 2-pole,250 VAC contactors. Retumbi U1111ty' Approx.13 see • Service equipment rated,dual coil design. Exercises bi-weekly for 5 minutes' Standard ETL or LL listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 'Function of Evolution controller Exercise can be set to weekly,bi-weekly,or monthly Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width Depth H1 H2 W2 1 3 6.9 BE W' �341 8 17.5 Ei,n 26.8 30.1 10.5 13.5 6.9 H1 cmi5 17,95 76.43 26.67 Wire Iiiiiiii --- ---- --- Conductor Lug Neutral Lug Ground Lug DEPTH W2 PWRview Automatic Transfer Switch Features Model G007210.0(24 kW) • Integrated PWRview monitor provides real-time energy usage data through PWRview app. No.of poles 2 Current rating(amps) 200 • Intel ligentiy manages up to four air conditioner loads with no additional hardware. Voltage fafint;(VAC) 120/240.10 • Up to eight additional large(240 VAC)loads can be managed when used In conjunction Utility voltage monitor(fixed)' BO% with Smart Management Modules(SMMs). -pick-lip .Dropout 65% • Electfically operated,mechanically-held contacts for fast,clean connections. Retumloullity, Approx.13 see • Rated for all classes of load 100%equipment fated,both inductive and resistive. Exercises bi-weekly for 5 minutes' Standard • 2-pole,250 VAC contactors. ETL or UL listed Standard Enclosure type NEMA 3R • Service equipment rated,dual coil design. Circuit breaker protected 22,000 • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller Exercise can be set to weekly,bi-weekly,or monthly 0 NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. - w1-• Heavy duty Generac Contactor is an ETL recognized device. Dimensions 200 Amps 120/240,1 o Open Transition Service Rated HeightI Width - T_- depth H1 H2 W1 In 26.8 30.1 10.5 1 135 6 H_T7._95 76.43 1 26. Wife a s Conductor Lug N�utralLug I Ground Lug 250 MCM-#6 350 MCM-#6 [ 2/0-#14 GENERAC 20/22/24 kW Available Accessories _ 11 � PFotluct Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the now air-cooled generators.'This offers a sleek„contoured (Standard on 22124 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located In the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,It Is important to touch up the paint to protect from hAure corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-Fi LP Tank Fuel Level The Ws-A enabled LP tank fuel levet monitor provides constant monitoring of the connected LP fuel tank.Monitonng the Monitor LP tank's fuel ievel Is an important step in verifying the generator is ready to run during an unexpected power failure,Sta- tus alerts are avaitabie through a tree application to notity users when the LP tank is In need of a Will, G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid In recovery when overloaded.In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-413 LTE Mobile Link"Cellular The Mobile Linktamiy of Cellular Accessories allow users to monitor generator status from anywttere In the world„using G007170-0-Wi-FU Accessories a smart phone,tablet,or PC.Easily access information such as the current operating staters and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UJJ� a x5 ,2,emm G007038-1 1074185 -. i ,Po asr [46A In] 13007038-3 6 647 074185 G007038-3 696471074185 � 0 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 72_2 mm 1286 nl G007042-3 696471074208 13007043-2 696471074215 G007043-3 696471074215 co O G007209-0 699 64710a 71511 13007210 0 696471078220 232 mm (25 in', ••• t4e.5 int LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. G "`N E RAC Generac Power Systems,Inc.• S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com C)2020 Generac Pourer Systems.Inc.All rights reserved,All specifications are subject to change without notice.Pan No.A0000937814 Rev.B 07/30/2020