Loading...
HomeMy WebLinkAbout47688-Z � t TOWN OF SOUTHOLD ' a BUILDING DEPARTMENT v TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 47688 Date: 4/18/2022m Permission is hereby granted to: Cockerill III, Adrian 87 Smith St A t 6C .._w...._..........-�.... _�w_..........._._.. .. ..wwwww_�..w._.......... w_..ww..... Brooklyn, NY 11201.. ._..mm...... ..... ..... .w_.................... ........ ........ To: Install accessory standby generator at existing single family dwelling as applied for. At premises located at: 26650 Route 25, Orient ._ www_.._ .._.._ .... www....._......_. _ www_............. SCTM # 473889 Sec/Block/Lot# 18.-6-11 Pursuant to application dated —3/14/.2.0.22 and approved by the Building Inspector.. To expire on 10/18/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-RESIDENTIAL $50.00 Total: _ $235.00 Building Inspector TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 � dpi Telephone (631) 765-1802 Fax (631) 765-9502 htti),;://wwwsoutholdtowiiny.gov Date Received APPLICATION FOR BUILDING PERMIT n (� For Office Use Only FF11V/ �.`""�, PERMIT NO. / Building Inspector. KI �� NIN Applications and forms must be filled out in their entirety. Incomplete BUILDING DEPT applications will not be accepted. Where the Applicant is not the owner,an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be completed. Date: 1:3 Z Z OWNER(S)OF PROPERTY: Name: � j� SCTM# 1000- Project Address: Phone#: ��� �Lo�0) Email: n d Mailing Address: lG� yt, tro Cl ,,,� ae— 11/ llC 3 CONTACT PERSON: Name: Mailing Address: Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: ��Zr�ti7i2� _ . Mailing Address: -Z-�� .��y�,� � c� �. Phone#: �0�� Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other �+ $ Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? es ❑No 1 PROPERTY INFORMATION ..................— Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ElYes E]No IF YES, PROVIDE A COPY. 0Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print n e): dAuthorized Agent El Owner Signature of Applicant: Date: /� �._ STATE OF NEW YORK) COUNTY OF being duly sworn, deposes and says that (s)he is the applicant (Name of individual signing contract) above named, (S)he is the (Contractor; t"..1—hcorporate Officer, etc.) of said owner or owners, and is duly authorized to pe or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of Ch 20 JALe..� -------------- �1, gNotary Public TRACEY L. DWYER NOTARY PUBLIC,STATE OF NEW YOF PROPERTY OWNER AUTHORIZATION NO.01 DW6306900 QUALIFIED IN TY (Where the applicant is not the owner) COMMISSION EXPIRESSUFFOLK JUNECOU30,N2-!� residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 �w uu „u B LDING DEPARTMENT-Electrical Inspector for TOWN OF SOUTHOLD own Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 %'Z',". . h o o 'soy Telephone (531) 755-1502 - FAX (531) 755-9502 rogerr@southoldtownny.gov - seand southoldtownn ov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 3 Ll '11- Company Company Name: 13, Electrician's Name: ',�-i ' License No.: Elec. email P r Elec. Phone No: ,S'"�� �''�ll Z3 C3 I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: A A-n-) Ooc ,;fC Address: 'o'l,i5�6 Cross Street: LA- Phone No.: 376 ee5—69d"`' Bldg.Permit#: email: �' M Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCL E SQUARE FOOTAGE (Please Print Clearly): Square Footage:-1 Circle All That Apply: Is job ready for inspection?: D YES[VD NCS, E]Rough In ElFinal Do you need a Temp Certificate?: DYES ]"ILIO Issued On Temp Information: (All information required) Service Size F11 Ph[]3 Ph Size: A # Meters Old Meter# ❑New Service[]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 D2 0 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION our tips on how to stay safe when transacting with Christie's. This message and any attachment are confidential.If you are not the intended recipient,please tekepl or emaii th edea and dIete th :a sa ear (2o any other person. ��*� �� Where the applicant is notthe owni er) n r4d er,$at', do hereby authorize W5 �r Apply of, rrty bOPSY,to the Town of Southold Bw ilding Department for approval as dtr gibed herein. 7 t t"mame t; r o rte,r„ r ,r , 3,i r .r/ „ r rr✓/lr, r �f I m r r r „ 1r r lr,, c r /� ✓ r l ,i.. ,/ /r�i r //i /-✓/ /�a,,/ // /,�/ a / -.,.. ,,, r i� /i / ,/, /. ,/ r /i r.,..////r it :.f r �:. „,f ,/ ///ir,, ,,„/,: I/r ;.�, �,, r „;,ry ,,, ;r, ,,,; r///%r,, %/j, ,r/�'�'r/%.r r✓/i�/ r/ r,r%r/iii/ rr / /////„/l''r P/r%r:"! r,✓"i/i///�////r /r!/ r /: r ✓./i, ,,,� r ;r, ,,, s" r /,r//r!„� -,✓/r„ ,/,,., / :ii % P, rii,// /ff�i//r/ r r; ��/ /'•%r / / r/' ;;, c„ „; / /„ ,�%r ;y�/ '�„oi 1, ;/i / r, i ur%i//%/ rf � � ",,,' e„u„J,r /✓.7f / /r, r /y 1, ,,, ,, / r / „rr ,r,,./ �,rr.,r„% � x ,I/ , „/✓fir//ri/J / ! // „r rr / r /�/ 11,,Y ro� Grl ,�,� 1 r�/!i✓� !i��/o ..ri ,,.;. if ,%. o' ;,, ,,,,. ,”h,„ i �/ !r /i/rr rr,.. r, / / r ,r ,,:, r r ” I ;, l� /r �<. ,,;,. ,, r,. ,, rrr r/ / / r /r / /i /. /r r ✓„i„ r r.,.l�frrrr��/r�//�//i x / �r ,rl r7.-r{i p, 1 �//ii r///; /// / aJ lr /, ,rr ✓ l: ��r�/,�f r//// v,;: rr,,,ir; / /.%',. in %✓ °, „; r r / F,r. .r � /.. / , :; / ,//, / ,. I, , ,r /� � ,/✓/l,/ rr r:: ,,,, /<./ ,,,,,,;; cr, ,< a, ,,,,,ri r. ,., r/i,/r;, r ///rr //, ,�„ � ✓/rr� ,� ��/� /.,r/f // r ,, ,... ,, /i /i�✓n,,.,./ /, // ����j,,,�/_, rp ,rr „e, r ,,, ul. / 1 /i.:,:, r�” /% /j /�"r 1// /,11➢ yy,' tf r/ /� ////rr//rr / %%p%�r i�/// r / / noon,r r Ve it ���� ��7 I 1 �// r i/r %r/rf//i//i // %'�//''%/'a///✓/�i r i'l�r!/1i . ( ” � � r� ���'P'” /r�rrr//r r '/i ✓/li''ri i/%/% / /, /�l � 0��f�i/�f r ✓, r 1 v�l� r'/P i��P� I�� �/9�rrr✓����/� � o I r' a f�r�r ��tl�jiifj lai 1A��rYi”!I//r, %�✓�/1f+l�l�/,/���fr/r�'rig r! ���� //�/frji r//l/r�i%i�✓I/ll%Irk p f rr 1� /�/ /i / r/ rr r✓ o �Yl rF ,jv;a x v r1/�lr� /�l✓,1r"� �%a�r / 11 l ) �Prrr// KOHLER. Models: 2 R ESC(L Multi-Fuel LPG/Natural Gas 09001 Standard Features "M KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying WN demand. o Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality. o OnCue@ Plus Generator Management System for remote monitoring is included with the generator. . Kohler Command PRO Engine Features o Kohler Command PRO®OHV engine with hydraulic valve Olifters for reliable performance without routine valve adjustment or lengthy break-in requirements. o Powerful,reliable air-cooled performance. o Simple field conversion between natural gas and LPG The Kohler® Advantage fuels while maintaining emission certification. • Designed for Easy Installation • High Ouality Power o Polymer base eliminates the need for a concrete Kohler home generators provide advanced voltage and mounting pad, reducing installation time and cost. frequency regulation along with ultra-low levels of o Fuel and electrical connections through the enclosure wall harmonic distortion for excellent generator power quality to eliminate the need for stub-ups through the bottom. protect your valuable electronics. o Load connection terminal block allows easy field wiring. • Extraordinary Reliability o Designed for outdoor installation only. Kohler is known for extraordinary reliability and o Certifications performance and backs that up with a 5-year or 2000-hour o Meets emission regulations for U.S.Environmental limited warranty. Protection Agency (EPA)with both natural gas and LPG. • Powerful Performance Note. CARR does not regulate emergency standby Exclusive Powerboost- technology provides excellent generators with outputs less than 50 HP. starting power. o UL 2200/cUL listed (60 Hz model). • Corrosion-Proof Enclosure o CSA certification available(60 Hz model). The bold new Kohler design is completely corrosion proof, o GOST certified (Russia). even in harsh seaside environments,and is impact- o Accepted by the Massachusetts Board of Registration of resistant even at-34° C (-30° F). Plumbers and Gas Fitters • Fast Response • Approved for stationary standby applications in locations Kohler generators restore power to your home quickly and served by a reliable utility source. reliably. . 20RESCL models packaged with a Model RXT automatic transfer switch are available. See page 6 and the Model RXT ATS specification sheet. • Warranty o Standard 5-year/2000-hour limited warranty for on-grid (standby)applications in locations served by a reliable utility source. G4-246 (20RESC) 1/19d Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 120* ._....... ._ _...... sO ....m. .__.._ ....._._. ..... _ _..... ._. .....__ 120 18/18 150 20/20 _w....... ...._166 175 1 110/220 1 60 18/18 81 20/20 90 100 2 * 120/240 1 60 18/18 75 20/20 83 100 2 2F7 100/200 _-......�M1 w_....5.01.5/15..._..��.w.75 16/16-_ __.....80 80 2 . 115/230 1 50 15/15 65 16/16 69 100 2 2201 1 50 15/15 68 16/16 72 80 1 230 1 50 15/15 65 15/15 65 80 2 2401 1 50 1313 54 ................ .........13/13. 54.... $Q 1.... .-........www..._,..._ww......._........._._....._...._........-._.w..._m_.w.ww.w._.._...... 120/208* 3 60 17/21.w .__.-.____-w.�..m......._�_...w..._._�..w____..............._. 58 17/21 58 70 3 110/220 3 60 17/21 55 17/21 55 80 3 127/220 3 60 17/21 55 17/21 55 80 4 120/240* 3 60 17/21 51 17/21 51 60 3 2G7 220/380 3 60 17/21 32 17/21 32 40 4 277/480* 3 60 17/21 26 17/21 26 30 3 100/200..........._........_...3..........w........ 50_..._14/17 _5 m-w.. w_w ..w.._15/18 w.-w_....._...._54--_.__.__63-_ w�.5... 220/380$ 3 50 14/17 26 15/18 28 32 4 230/400 3 50 14/17 25 15/18 27 32 4 240/416$........_.. 3 ...........www. 50.�.......m......., 14/17 ..24_....w_�._.._.ww._.....15/18w.. 26 w..........._.. ...w._w 32_...w�.�..._...._m--.w4.�..._�.�.�M. * UL listed. t 50 Hz single-phase models are factory-connected as 230 volts.Field-adjustable to 220 or 240 volts by an authorized service technician. t 50 Hz 3-phase models are factory-connected as 230/400 volts.Field-adjustable to 220/380 or 240/416 volts by an authorized service technician. Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATING&Standby ratings appy"to 6 s9apas oris se voot by a fetaabto utility source,All three-phase utatts aro sated a1O,8 powaea faactor Afl single-phase units are rated at 1.0 power faactorrtw starrdtwy rasttrugtss<spplic�aWetovtarfableWdswith anawerageloadfacto?'ofso%foa,ttaedwatio�nof1hepower outage RatIndsare inacowdaancewith MO-304011 SS651+,AS2769,and DIN 6271.GENERM.GUIDEt.1Nt^S FOR DERATING:F+L'!"fTUDE:Derate 4'%per 305 or(1000 lt,p etovatlon above 1.63 m(600 ft) rf PERA URE'.Defefe 2%per 5,6"C (191F)temperature increase above 16°C(60°F).Ava ab!Rtyissubjecttochangow6thr4�dnoticeThe generator Sol rnarrufaciarrerreser asttaeright tarefi2,a the dodge+or specificafianswrilhordnotice and without any obligaBton or 4041ty whatsoever. Contact your local Kohler Car gfoatwator fteibutor for availability. G4-246 (20RESC) 1/19d . . Alternator Specifications Alternator Specifications Alternator Features Specifications Alternator # Compliance with NEMA, IEEE,and ANSI standards for Manufacturer Kohler temperature rise. Type 2-p»|e.Rotating Field a Self-ventilated and drippmofconstruction. Leads,' * Windings vacuum-impregnated with epoxy varnish for 2F7 ^ dependability and long life. 2g7 12 o Superior voltage waveform and minimum harmonic Voltage regulator Digital distortion from skewed alternator construction. Insulation: NEMAMG1-1.66 # D �gu|�nrwkh±1.0& no-load tofuU�oad Material Class =-- '— - RMS regulation. Temperature rise(60Hz) 130"CBtandby T�mper�unehae�oH� 1501C Standby � Ro|et|ng'hm|dakerne�nrwith stc�icexciter for exceUeni load response. Bearing:quantity,type 1,Sealed * Total harmonic distortion O[HC0from nuload 10full load with Coupling Direct Direct alinear load ialess than 5%. Amprtisaeurw|ndmga Full Voltage regulation,no-load mfull-load RMS :t 1.0% One-step load acceptance 1oomovRating Peak motor starting kVA: (3omdip for voltages below) 240V,1pn up7(4lead) 41 (6oHz) 230 V,1 ph 2p7(4 lead) co(50 Hz) 240o,4e0X3Pn oaz(1olead) so(6oHz) 208o,*16X3Ph uor(1ulead) oo(5oHz) a+246w0nsoq ,00u Application Data Engine Fuel Pipe Size Engine Specifications Minimum Gas Pipe Size Recommendation,in.NPT Manufacturer Kohler Natural Gas LPG Engine:model,type CH 1000 4-Cycle Pipe Length, 261,000 340,000 Cylinder arrangement V-2 m(K•) Btu/hr. Btu/hr. Displacement,cm3(cu.in.) 999(61) 8 (25) 1 3/4 Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) 15 (50) 1 1 Compression ratio 8.8:1 30 (100) 1 1/4 1 Main bearings:quantity,type 2,Parent Material 46 (150) 1 1/4 1 1/4 Rated RPM 61 (200) 1 1/4 1 1/4 60 Hz 3600 Fuel Requirements 50 Hz 3000 q Max.engine power at rated rpm, Fuel System kW(HP) Fuel types Natural Gas or LPG LPG,60 Hz 23.0(30.9) Fuel supply inlet 1/2 NPT LPG,50 Hz 20.0(26.8) Fuel supply pressure,kPa(in.H2O)'. Natural gas,60 Hz 20.2(27.1) Natural gas 0.9-2.7(3.5-11) Natural gas,50 Hz 16.8(22.5) LP 1.7-2.7(7-11) Cylinder head material Aluminum Fuel Composition Limits* Nat.Gas LPG Valve material Steel/Stellite® Methane,%by volume(minimum) 90 min. - Piston type and material Aluminum Alloy Ethane,%by volume(maximum) 4.0 max. - Propane,%by volume 1.0 max. 85 min. Crankshaft material Heat Treated,Ductile Iron Propene,%by volume(maximum) 0.1 max. 5.0 max. Governor:type Electronic C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,no load to full load Isochronous Sulfur,ppm mass(maximum) 25 max. Frequency regulation,stead state X0.5% Lower heating value, q y p y MJ/m3(Btu ), (minimum) 33.2(890) 84.2(2260) Air cleaner type Dry * Contact your local distributor for suitability and rating Berates based Engine Electrical on fuel compositions outside these limits. Engine Electrical S stem operation Requirements Ignition system Electronic, Capacitive Discharge Fuel Consumption ..... Starter motor rated voltage(DC) 12 Fuel Fuel Consumption,m3%_.. p hr.(cfh) Battery(purchased separately): Model Type %Load 60 Hz 50 Hz Ground Negative 100 8.0 (281) 6.4 (225) Volts(DC) 12 75 6.9 (243) 5.4 (189) Natural 50 4.6 (161) 3.9 (139) Battery quantity 1 Gas Recommended cold cranking amps: 25 3 6 ( 2 9 ( (71) (71) Exercise 2 0 (71 (CCA)rating for-1 B°C(0°F) 500 20RESC ) 2 0 (71) Group size 51 100 3.9 (136) 2.9 (102) 75 3.1 (109) 2.4 (85) Exhaust LPG 50 2.3 (82) 1.8 (63) Exhaust System 25 1.7 (59) 1.3 (47) Exercise 1.0 (35) 1.0 (35) Exhaust temperature exiting the ( ) Nominal fuel rating NPat ral gas: 93 MJ/m3(2500µBtu/ft 3 enclosure at rated kW,d C 260 500 ) Lubrication LPG conversion factors: 8.58 ft.3=1 Ib. System 0.535 m3=1 kg Lubricating y 36.39 ft. =1 gal. Type Full Pressure Oil capacity(with filter),L(qt.) 1.9(2.0) Oil filter:quantity,type 1,Cartridge Oil cooler Integral G4-246 (20RESC) 1/19d RDC2 Controller _....._.....µ,_n • Front-access mini USB connector for SiteTech- or USB Utility connection r soot � • Integral Ethernet connector for Kohler@ OnCue®Plus • Built-in 2.5 amp battery charger "i a • Remote two-wire start/stop capability for optional connection , m. of a Model RDT transfer switch • Diagnostic messages: wn ~" o Displays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface The RDC2 controller provides integrated control for the module(PIM), and load shed kit generator set, KohlerO Model RXT transfer switch, o Over 70 diagnostic messages can be displayed programmable interface module(PIM), and load shed kit. • Maintenance reminders The RDC2 controller's 2-line LCD screen displays status • System settings: messages and system settings that are clear and easy to read, o System voltage,frequency,and phase even in direct sunlight or low light. o Voltage adjustment o Measurement system, English or metric RDC2 Controller Features • ATS status (Model RXT ATS required): o Source availability • Membrane keypad: o OFF,AUTO, and RUN pushbuttons o ATS position (normal/utility or emergency/generator) o Select and arrow buttons for access to system o Source voltage and frequency configuration and adjustment menus • ATS control (Model RXT ATS required): • LED indicators for OFF,AUTO, and RUN modes o Source voltage and frequency settings • o Engine start time delay LED indicators for utility power and generator set source o Transfer time delays availability and ATS position (Model RXT transfer switch o Voltage calibration required) o Fixed pickup and dropout settings • LCD display: . o Two lines x 16 characters per line Programmable Interface Module (PIM)status displays: o Backlit display with adjustable contrast for excellent o Input status (active/inactive) visibility in all lighting conditions o Output status (active/inactive) • Scrolling system status display: + Load control menus: o Generator set status o Load status o Voltage and frequency o Test function o Engine temperature o Oil pressure Generator Set Sound Data o Battery voltage Model 20RESC 8 point logarithmic average sound levels are o Engine runtime hours 64 dB(A) during weekly engine exercise and 69 dB(A) during • Date and time displays full-speed generator diagnostics and normal operation. For • Smart engine cooldown senses engine temperature comparison to competitor ratings,the lowest point sound levels • Digital isochronous governor to maintain steady-state speed are 62 dB(A) and 67 dB(A) respectively.* at all loads All sound levels are measured at 7 meters with no load. • Digital voltage regulation: ±1.0% RMS no-load to full-load * Lowest of 8 points measured around the generator. Sound levels at • Automatic start with programmed cranking cycle other points around generator may vary depending on installation • Programmable exerciser can be set to start automatically on parameters. any future day and time, and run every week or every two weeks • Exercise modes: o Unloaded weekly exercise with complete system diagnostics o Unloaded full-speed exercise o Loaded full-speed exercise (Model RXT ATS required) G4-246 (20RESC) 1/19d KOHL � H �E �® Phone 9 CO.,Kohler,Wisconsin 9-164 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Available Options, Continued • Battery cables Maintenance • EPA certified fuel system ❑ Maintenance kit(includes air filter, oil,oil filter, and • Corrosion-proof polymer sound enclosure spark plugs) • Critical silencer Warranty • Field-connection terminal block ❑ Optional Extended 5-Year/2000 Hour Comprehensive Limited • Fuel solenoid valve and secondary regulator Warranty • Line circuit breaker Automatic Transfer Switches and Accessories • Multi-fuel system, LPG/natural gas,field-convertible ❑ Model RDT ATS • Oil drain extension with shutoff valve ❑ Model RXT ATS • OnCue@ Plus Generator Management System ❑ Model RXT ATS with combined interface/load • Premium 5-year limited warranty management board generator set/ATS controller [j Load shed kit for RXT or RDT • RDC2 9 ❑ Power relay modules (use up to 4 relay modules for • Rodent-resistant construction each load management device) • Sound-deadening,flame-retardant foam per UL 94, ❑ Other Kohler@ ATS class HF-1 20RESCL Model Packages Available Options ❑ 20RESCL with 100 amp RXT with 16-space load center and NEMA 1 steel enclosure for indoor installation Approvals and Listings ❑ 20RESCL with 200 amp service entrance-rated Model ❑ CSA approval RXT with combined interface/load management board Communication Accessories and corrosion-resistant NEMA 3R aluminum enclosure ❑ OnCue@ Plus Wireless Generator Management System Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ❑ Concrete mounting pad,4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery Generator Set Dimensions and Weights C] Battery heater, 120VAC Overall Size,L x W x H: 1216 x 665 x 733 mm (as x 26.2 x 29 in.) r-1Battery heater,240VAC ❑ Cold weather package, 120VAC Shipping Weight: 243 kg (535 Ib.) ❑ Cold weather package,240VAC Shipping Weights: ❑ Emergency stop kit 20RESC Generator Set: 243 kg(535 Ib.) ❑ PowerSync@ Automatic Paralleling Module (APM) 20RESCL with 100 A RXT ATS w/LC 268 kg(591 lbs.) (single phase only) 20RESCL with 200 A RXT SE ATS: 263 kg(580 Ib.) ❑ Programmable interface module(PIM) L w .. . (provides 2 digital inputs and 6 relay outputs) ...... Fuel System Accessories ❑ Flexible fuel line(included on Quick-ship[QS] models) ❑ Carburetor heater, 120 VAC H ❑ Carburetor heater,240 VAC Carburetor heater is recommended for reliable starting FW at temperatures below 0°C (32°F) ❑ Fuel regulator heater pad 120VAC NOTE: Dimensions are rovided for reference onl and should not bused f ❑ Fuel regulator heater pad 240VAC p y for planning installation.Contact your local distributor for more detailed information. Fuel regulator heater is recommended for reliable starting at temperatures below-16°C (0°F). DISTRIBUTED BI Literature ❑ General maintenance literature kit ❑ Overhaul literature kit ❑ Production literature kit ©2015,2016,2017,2019 by uta hoer Co. All rights reserved. 34-246 (20RESC) 1/19d