Loading...
HomeMy WebLinkAbout47464-Z NOTES B � 1°" 30' 10" 1. NO SOILSURCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION AT THE SHALLOW END,OR 6 FEET OF EXCAVATION AT THE DEEP END. 0 74& o o I 2. THIS POOL MEETS THE REQVIREMENTSOFAN51/APSP/ICC-5"AMERICAN NATIONAL STAN PARD FOP RESIDENTIALINGROVNDSWIMMING Q POOLS'°AND 1996 BOCA CODE-SECTION 421.DIVING EQUIPMENT IS NOTALLOWED. n- 3. SWIMMING POOL SHALL BE COMPLETELY AND CONTINUOUSLY SURROUNDED WITH ABARRIERCON5TRVCTTDIAW REQUIREMENTS OF "U A SECTION R326.4.2.1 THROUGH R326.4.2.6OFTHE NEW YORK STATE RESIDENTIAL CODE(2020)AND IN CONFORMITY WITH ALL SECTIONS OF THE 50UTHOLP TOWN COPE.DWELLING WALLS)MAY SERVE AS PART OF THE POOL BARRIER AS PEP SECTION R326.4.2.8 AND I s•-o� 3•-6" CONDITION(1)ARE MET.OPERABLE WINDOWS IN THE WALL(5)USED ASA BARRIERSHALL HAVE SELF LATCHING DEVICE.ACCESS GATES O r, H2O H20 SHALL COMPLY WITH SECTION P326.5.2 OF THE NYS RESIDENTIAL CODE(2020)AND BE SELF CLOSING,SELF LATCHING AND BE SECURELY O m LOCKED WHEN POOL 15 NOT IN USE OR SUPERVISED.ALL GATES ARE TO OPEN AWAY FROM THE POOLAREA. [l, } 4. DURING CONSTRUCTION THE CONTRACTOR SHALL ERECTA TEMPORARY BARRIERAROUND THE EXCAVATION IAW THE CODE OF THE V v TOWN OF SOUTHOLD. z QZ 5. POOL MUST BE EQUIPPED WITH AN APPROVED POOLALARM CAPABLE OF DETECTING ENTRY INTO THE WATERAND SOUNDING AN N c AUDIBLE ALARM UPON DETECTION THAT IS AUDIBLE ATPOOISIDEAND IN51PETHE DWELLING. THE ALARM MUST BE INSTALLED, Rj 'p MAINTAINED AND USED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. THE ALARM MUST MEETA5TM F2208 3 a "STANDARD SPECIFICATION FOR POOLALARMS. THE DEVICE MUSTOPERATE INDEPENDENT(NOT ATTACHED TO OR DEPENDENTON)OF 18' 12' a PERSONS. <- u 6. POOL SUCTION FITTINGS(EXCEPT FOR SURFACE SKIMMERS)MUST BE PROVIDED WITH A COVER THATCONFORMS TO A5ME/ANSI 10'" PLAN /� 10" A112.19.8MORAMINIMUM I8"x23'DRAIN GRATE OR A CHANNEL DRAIN SYSTEM. POOL CIRCULATION SYSTEM MUST BE EQUIPPED WITH ATMOSPHERIC VACUUM RELIEF IN THE EVENTTHE GRATE COVERS LOCATED WITHIN THE POOL BECOME MISSING OR BROKEN.SUCH N.T.S. ' VACUUM RELIEF 5YSTEM5 SHALL CONFORM WITH A5ME A112.19.17 OR BE A GRAVITY SYSTEM APPROVED BY THE TOWN OF SOUTHOLD. POOL SHALL BE PROVIDED WITH A MINIMUM OF SUCTION FITTINGS OF THE ABOVE MENTIONED TYPE. THE SUCTION FITTINGS SHALL BE SEPARATED BY MINIMUM OF3'AND MUST BE PIPED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS) VACUUM/PRE55UP E CLEANING FITTINGS SHALL BE IN AN ACCESSIBLE 12'VINYL COVERED POSITION,MINIMUM OF 6"AND NO GREATER THAN 12"BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BEAN ATTACHMENTTO CONCRETE STEPS THE SKIMMER/5KIMMERS.A REQUIRED POOL ATMOSPHERIC VACUUM RELIEF SYSTEM SHALL BE INSTALLED AS PER NY5 RESIDENTIAL CODE R326.6.3(2020)AND IN ACCORDANCE WITH TOWN CODE. qj XJ zo k+ 7. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC)PRINCIPALLY ARTICLE 680 AND THE NY5 QJ RESIDENTIAL CODE SECTIONS 4201 THROUGH 4206.ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND "CS Y 2"TO4"$AND BOTTOM BE PROTECTED BY GROUND FAULT CURRENT I NTERRUPTER(G FCI)CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE n y PROVIDING POWER TO POOL LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OFTAB&LE E4203.5.ALL N METAL ENCLOSURES,FENCES OR RAILINGS NEAR ORAD)ACENTTOTHE SWIMMING POOLTHATMAYBECOME ELECTRICALLY CHARGED DUE TO CONTACT WITH AN ELECTRICAL CIRCVITSHALL BE EFFECTIVELY GROUNDED. ,� cz N Ln SECTION A S. WATER SOURCE FILLING THE POOLSHALL BE EQUIPPED WITH A BACKFLOW PROTECTION DEVICE LAW NYS PLUMBING COPE608. ti 00 } N.T.5. 9. ALL PIPING 15 DIAGRAMMATIC UNLE55 OTHERWISE STATED. p _y Z L�. TOP OF WALL WATER LINE 10. WALKS IF PROVIDED SHALL BE NONSLIP AND SLOPE AWAY FROM POOL EDGE. v ;F+ --6-'--, 4, 4 fV 11. A MEANS OF EGRESS FOR DEEP AND SHALLOW ENDS MUST.BE PROVIDED IAW AN51/APSP/ICC-5 SECTION b. - p C) 12. CONTRACTOR TO PLACE THE POOL IAW TOWN OF SOUTHOLD CODE SETBACKS. N :F 13. ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SVB)ECT PROPERTY. 15. THE DESIGN 15 BASED ON A DRAINAGE SOIL WITH<10%SILT GROUND WATER SHALL NOT EXI5T WITHIN THE EXCAVATION. IFGROVND N WATER EXISTS WITHIN 6'-0"FROM GRADE,DEWATERING FACILITIES WILL BE REQUIRED. QN SECTION B 16. ALL GAS AND OIL HEATERS(IF IN51ALLEP)FOP,THE INGROUND SWIMMING POOL5HALL BE NATIONAL APPLIANCE ENERGY r CONSERVATION ACT(NAECA)COMPLIANT. POOL HEATERS SHALL BE TESTED IAW ANSI 221.56 AND SHALL BE INSTALLED IAW N.T.S. MANVFACTVRERS SPECIFICATIONS. OIL FIRED POOL HEATERS SHALL BE TESTED IAW UL726. POOL HEATERS SHALL BE LOCATED OR GUARDED TO PROTECT AGAIN5TACCIDENTALCONTACT OF HOT SURFACES BY PERSONS, POOL HEATERS SHALL BEPROVIPEP WITH ,± TEMPERATURE AND PRE55VRE-RELIEF VALVES. FOR HEATERS NOT PROVIDED WITH AN INTEGRAL BYPASS SYSTEM.A BYPASS LINE SHALL BE u N INSTALLED FROM INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HEATER. POOL HEATERS SHALL BE PROVIDED WITH THE 2,-2„ FOLLOWING ENERGY CONSERVATION MEASURES: I p`fp CHECK VALVE COPING AND WALKWAY 10" v 00 O (BY 16.1 AT LEAST ON E THERMOSTAT SHALL BE PROVIDE[)FOR EACH HEATING SYSTEM. PUMP FROM SKIMMER GRADE 16.2 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TO ALLOW SHUTTING OFF THE WATERLINE OPERATION OF THE HEATER WITHOUTAD)USTI NG THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE A( �- 8 PILOTLIGHT W T TODI� 16.3 HEATED 5WIMMI NG POOLS SHALL BE EQUI PPED WITH A POOL COVER(EXEMPTED FROM THIS REQUIREMENT AP E OUTDOOR POOLS W (D CRVWELL UNDISTURBED EARTH - DERIVING 20%OF THE ENERGY FOR HEATING FROM REN EWABLE SOUR CES AS COMPUTED OVER AN O PERATI NG SEASON) W <r co c* G 16.4 TIME CLOCKS SHALL BE INSTALLED 50 THE PUMP CAN BE SC-T TO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODSAND CAN BESET ca C 3500 P51 POURED CONC. d w TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER IN A CLEAN AND SANITARY CONDITION IAW APPLICABLE N DIVERTER O 3/B"REBAR.(2)TY. < SAN ITARY CODE OF NEW YORK STATE. �i a a VALVE r VINYL LINERS \ E� O . d 17. THIS DRAWING 15 FOR STRUCTURAL SHELL ONLY.ALL ACCES5ORIE5AND APPURTENANCES ARE DEFINED BYOTHER5. � x�MMCdJ `d 2"TO 4"SAND i �� w ti C w co y O FILTER . '. 18. BACKFILL WITH CLEAN EART�I,FREE OFROOTSANDDEBRIS. DONOTALLOWTHE HEIGHT OFBACKFILL TOEXCEED THIEHEIGHT OFTHE N� iG .0 \\\ - WATER IN THE POOL BY MORE THAN 8", OR THE WATER TO EXCEED BACKFILL BY MORE THAN 8" i Q Ly 19. PLACE CONCRETE ON SANDY TO LOAM SOIL, REMOVE ANY CLAY DEPOSITANDREPLACE W/COMPACTED CLEAN BACKFILL. a P. TO RETURNS 20. THERE IS NO MAIN DRAIN IN THI5 POOL.SUCTION FOR POOL WATER CIRCULATION 15 PROVIDED BY THE SKIMMERS ONLY.THI5 MEETS J CHECKVALVEJ REQUIREMENTS OF THE NYS RESIDENTIAL COPE-SECTION R326.5FORENTRAPMENT PROTECTION. - AEW r0 PLUMBING SCHEMATIC 21. THE POOL WAS DESIGNED IAW THE FOLLOWING: �� HOM,q e- s N.T5. WALL SECTION 21.1. THE NEW YORK STATE RESIDENTIAL CODE-SECTION R326(2020) 21.2. THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE-SECTION R40 020) { '�, moi CC N.T.S. 21.3. THE NEW YORK STATE FUEL GAS CODE(2020) w E C E \111 21.4. THE NEW YORK STATE SANITARY CODE. J 1J LLLU) i "t W 21.5. ANSI/APSP/ICC-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS. Z 21.6. BOCACODE-SECTION 421. 21.7. CODE OF THE TOWN OF SOUTHOLD, J('1n1tl�I 5 22. ALL BACKWASH TO BE SELF-CONTAINED ON-SITE. + �� BUILDING DEPT. S� 08a�� TOWN OF SOUTHOLD \C _'°RCFESS.