HomeMy WebLinkAbout46310-Z �o�aSU�1 o Town of Southold 12/18/2021
a P.O.Box 1179
0
v' 53095 Main Rd
Southold,New York 11971
Y`
CERTIFICATE OF OCCUPANCY
No: 42634 Date: 12/18/2021
THIS CERTIFIES that the building SOLAR PANEL
Location of Property: 1535 Westview Dr.,Mattituck
SCTM#: 473889 See/Block/Lot: 107.-7-10
Subdivision: Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore filed in this office dated
5/10/2021 pursuant to which Building Permit No. 46310 dated 5/25/2021
was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for
which this certificate is issued is:
roof mount solar panels to existing single family dwelling as applied for.
The certificate is issued to Hurley III,John&Maureen
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL
ELECTRICAL CERTIFICATE NO. 46310 7/8/2021
PLUMBERS CERTIFICATION DATED
\\QL/
A ho iz U
ignature
o�SUFFa� TOWN OF SOUTHOLD
aye BUILDING DEPARTMENT
y TOWN CLERK'S OFFICE
SOUTHOLD, NY
BUILDING PERMIT
(THIS PERMIT MUST BE KEPT ON THE PREMISES
WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS
UNTIL FULL COMPLETION OF THE WORK AUTHORIZED)
Permit#: 46310 Date: 5/25/2021
Permission is hereby granted to:
Hurley III, John
PO BOX 102
Mattituck, NY 11952
To: Install roof mount solar panels to existing single family dwelling as applied for.
At premises located at:
1535 Westview Dr., Mattituck
SCTM #473889
Sec/Block/Lot# 107.-7-10
Pursuant to application dated 5/10/2021 and approved by the Building Inspector.
To expire on 11/24/2022.
Fees:
SOLAR PANELS $50.00
ELECTRIC $100.00
CO-ALTERATION TO DWELLING $50.00
Total: $200.00
Building Inspector
OF SO(/r�ol
Town Hall Annex ~ O Telephone(631)765-1802
54375 Main Road Fax(631)765-9502
P.O.Box 1179 G Q .n sean.deviin(c-town.southoldus
Southold,NY 11971-0959 �Ol • �O y
yCOW T`I,�
BUILDING DEPARTMENT
TOWN OF SOUTHOLD
CERTIFICATE OF ELECTRICAL COMPLIANCE
SITE LOCATION
Issued To: John Hurley III
Address: 1535 Westview Dr city,Mattituck st: NY zip: 11952
Building Permit#: 46310 Section: 107 Block: 7 Lot: 10
WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE
Contractor: DBA: Fulton Electric License No: 54016ME
SITE DETAILS
Office Use Only
Residential X Indoor X Basement Solar X
Commerical Outdoor X 1st Floor Pool
New X Renovation 2nd Floor Hot Tub
Addition Surrey X Attic Garage
INVENTORY
Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan
Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors
Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors
Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO
Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks
Disconnect Switches 4'LED Exit Fixtures Pump
Other Equipment: 9kW Roof Mounted PV Solar Energy System w/ (25)REC360AA Panels,
PV AC Disconnect, Enphase IQ Combiner 3 w/220x2 215x1
Notes: Solar
1
Inspector Signature: S:2Date: July 8, 2021
S.Devlin-Cert Electrical Compliance Form.xls
o�aOF SOUIyOIH �
-
* TOWN O SOUTHOLD BUILDING DEPT.
co 765-1802
INSPECTION
I ] FOUNDATION 1ST [ ] ROUGH PLBG.
[ ] FOUNDATION 2ND` [ ] INSULATIOWCAULKING
[ ] FRAMING /STRAPPING [ ] FINAL
[ ]-FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION
[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATIONS
[ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)
[ ] CODE VIOLATION ] PRE C/O
REMARKS: 'L--
DATE INSPECTOR c �-
pF SOUTyOIo
# # TOWN OF SOUTHOLD BUILDING DEPT.
765-1802
INSPECTION
[-` ] FOUNDATION IST [ ] ROUGH PL13G.
[ ] FOUNDATION 2ND ° [ ] IOULATIOWCAULKING
[ ] FRAMING /STRAPPING [ FINAL
[ " ].."FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION-
[ ] FIRE RESISTANT CONSTRUCTION [ ]. FIRE RESISTANT PENETRATION
[ ] ELECTRICAL (ROUGH). [ ] ELECTRICAL (FINAL)
[ ] CODE VIOLATION [ ] PRE C/O
REMARKS:
cq
1, 3,o12,o2-(DATEINSPECTOR
Graham Associates 1981 Union Blvd. Bay Shore, N.Y. 11706
Building Consultants& Expeditors (516) 665-9619 Fax(516) 969-0115
June 22, 2021
Town of Southold
Building Department
Town Hall Annex
P.O. Box 1179
Southold, NY 11971
Re: Hurley Residence—1535 Westview Dr, Mattituck, NY 11952
SCTM#1000-107-07-010
Permit No.46310—9.0 kW Rooftop Solar Photovoltaic System
To Whom It May Concern,
Please be advised that I have inspected the solar roof array at 1535 Westview Dr, Mattituck, NY
11952 and have determined that it has been performed in accordance with the manufacturer's
recommendations,and the approved building permit.The installation meets the 2020 NYS Building
Code, 2018 International Code, and ASCE 740.
If you have any further questions, do not hesitate to call.
O ARC
in G GY,.--L K. o y�Tc�,
r � ti
C.A
�<90
M i c 61R.rQ
FIELD;INSPECTION REPORT DATE G01�1�F,AiT�;
FOUNb.:4TION(IST)
FOUNDATION (2ND) '
i
FRAMING&
' ROUGH '
P)� ING
ble
INSU44. ION•PER N..Y.
STATE!ENERGY
TNAL
.40
— -i IDiyun:1 ;
:-- 0.
� . z
i
TOWN OF SOUTHOLD—BUILDING DEPARTMENT
Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959
Q (1
hof '
Telephone 631 765-1802 Fax 631 765-9502 httis://www.southoldtownn . ov
P � ) � ) 1 �
,dol- °�a;�• --- ---
Date Received
APPLICATION FOR BUILDING; PERMIT
For Office Use Only
PERMIT NG.
6310 Building Inspector:
Applications and forms must be filled out in their entirety.Incomplete
applications will not be accepted. Where the Applicant is not the owner,an
Owner's Authorization form(Page 2)shall be completed.
Date: 5/5/2021
OWNER(S)OF PROPERTY:
Name: John Hurley SCTM#1000- 107-07-010
Project Address: 1535 Westview Drive, Mattituck
Phone#: (631) 298-8242 Email: jack.hurley@att .net
Mailing Address: p.o. Box 102 , Mattituck, NY 11952
CONTACT PERSON:
Name: Thomas Casey
Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone#: (631) 647-3402 Email: tom@harvestpower.net
DESIGN PROFESSIONAL INFORMATION:
Name: Michael Dunn, R.A.
Mailing Address: 1981 Union Blvd, Bay Shore, NY 11706
Phone#: (631) 665-9619 Email: Bayblueprint@aol .com
CONTRACTOR INFORMATION:
Name: Harvest Power LLC
Mailing Address: 2941 Sunrise Hwy, Islip Terrace, NY 11752
Phone#: (631) 647-3402 Email: tim@harvestpower.net
DESCRIPTION OF PROPOSED CONSTRUCTION
❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project:
®0ther Solar $ 30, 000 . 00
Will the lot be re-graded? ❑Yes ONO Will excess fill be removed from premises? ❑Yes [:]No
1
DocuSign Envelope ID:853F9E8D-8CD0-48C8-A207-022251A55FA8
PROPERTY INFORMATION
Existing use of property: Residence Intended use of property: (no change)
Zone o use district in which premises is situated: Are there any covenants and restrictions with respect to
R idential this property? ❑Yes ®No IF YES, PROVIDE A COPY.
Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by
Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone
Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings,
additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,
housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are
punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law.
Application Submitted By(print name): ®Authorized Agent El Owner
Signature of Applicant:(/ Date: -/17eT/
STATE OF NEW YORK)
SS:
COUNTY OF ,�3 1h, ��(�,)
�Ut�'1GdS being duly sworn,deposes and says that(s)he is the applicant
(Name of individual signing contract) Bove named,
(S)he is the Contractor as Agent
(Contractor,Agent, Corporate Officer,etc.)
of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this
application;that all statements contained in this application are true to the best of his/her knowledge and belief; and
that the work will be performed in the manner set forth in the application file therewith.
Sworn before me this
(0 day of 20 624
__71TIITARY PUBLIC-STATk OF NEW YORK otary Public
No.01OT6256196
Oualified iSuffolk County
My Coommiss on xpi es 02 210PEOPERT_Y_OWNER-Al1THORIZATION.
(W erg Ican is no a owner -
I, John Hurley residingat 1535 Westview Drive, Mattituck
do hereby authorize-Ad mQ° Harvest Power LLC to apply on
my behalf to the Town of Southold Building Department for approval as described herein.
DocuSigned by: f/
_F
D8M?JWVSignature Date
John Hurley
Print Owner's Name
2
DocuSign Envelope ID:853F9E8D-8CD0-48C8-A207-02225lA55FA8
CONSENT TO INSPECTION
i
t
t
John Hurley
,the undersigned,do(es)hereby state:
Owner(s)Name(s)
That the undersigned(is) (are)the owner(s)of the premises in the Town of
Southold, located at 1535 Westview Drive, Mattituck ,
which is shown and designated on the Suffolk County Tax Map as District 1000,
Section 10 7 , Block 07 ,Lot 010
i
t
That the undersigned(has)(have)filed,or cause to be filed,an application in the
Southold Town Building Inspector's Office for the following:
Installation of a 9 . 0 kW Solar PV System with
(25) REC360AA Roof-mounted panels
That the undersigned do(es)hereby give consent to the Building Inspectors of the
Town of Southold to enter upon the above described property, including any and all
buildings located thereon,to conduct such inspections as they may deem necessary with
respect to the aforesaid application, including inspections to determine that said premises
i
comply with all of the laws,ordinances, rules and regulations of the Town of Southold.
i
The undersigned, in consenting to such inspections;do(es)so with the knowledge
and understanding that any information obtained in the conduct of such inspections may
be used in subsequent prosecutions for violations of the laws, ordinances, rules or
regulations of the Town of Southold.
DocuSigned by-
cL►�at � � 7rd 1
•—Ds�uc3 � Cures.
John Hurley
_C%pAture)T
(sPrName '-
L
O� SUFFQ(_. I DING DEPARTMENT-Electrical Inspector
JUN 25 2021 TOWN OF SOUTHOLD
o. Town Hall Annex- 54375 Main Road - PO Box 1179
iuMDING DUT, Southold, New York 11971-0959
,TT 1
=fftphone (631) 765-1802 - FAX (631) 765-9502
roQerr(cbsoutholdtownny.gov seand(c�southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 6/23/21
Company Name: Fulton Electric, Inc.
Name: John D'Aries
License No.: 54016-ME email: jott@harvestpower.net
Phone No: (631) 234-5940 01 request an email copy of Certificate of Compliance
Address.:c/o Harvest Power 2941 Sunrise Hwy, Islip Terrace,NY 11752
JOB SITE INFORMATION (All Information Required)
Name: John Hurley
Address: 1535 Westview Drive, Mattituck
Cross Street: Brower Road
Phone No.: (63,1) 298-8242
Bldg.Permit#: 46310 email: jott@harvestpower.net
Tax Map District: 1000 Section: 107 Block: 07 Lot: 010
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
Installation of a 9. 0 kW Solar PV System w/ (25)REC360AA Roof-Mounted Panels
Check All That Apply:
Is job ready for inspection?: ✓❑YES ❑NO ❑Rough In OFinal
Do you need a Temp Certificate?: DYES. ONO Issued On
Temp Information: (All information required)
Service Size 01 Ph ❑3 Ph Size: 200 A # Meters,_ _':1 Old Meter#
❑✓ New Service ❑ Service Reconnect ❑ Underground ❑✓ Overhead
# Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N
Additional Information:
PAYMENT DUE WITH APPLICATION
Electrical Inspection Form 2020.xlsx
Sof kQL 110ING DEPARTMENT- Electrical Inspector
JUN 2 5 2021 TOWN OF SOUTHOLD
darn Town Hall Annex - 54375 Main Road - PO Box 1179
W _ 1aTjMT)1NODF-PT° Southold, New York 11971-0959
y 0� r 610hone (631) 765-1802 - FAX (631) 765-9502
ro4err(cD-southoldtownny.gov— seand(�southoldtownny.gov
APPLICATION FOR ELECTRICAL INSPECTION
ELECTRICIAN INFORMATION (All Information Required) Date: 6/23/21
Company Name: Fulton Electric, Inc.
Name: John D'Aries
License No.: 54016-ME email: ,jof@harvestpower.net
Phone No: (631) 234-5940 QI request an email copy of Certificate of Compliance
Address.: c/o Harvest Power 2941 Sunrise Hwy, Islip Terrace,NY 11752
JOB SITE INFORMATION (All Information Required)
Name: John Hurley
Address: 1535 Westview Drive, Mattituck
Cross Street: Brower Road
Phone No.: (631) 298-.,8242
Bldg.Permit#: 46310 email: jott@harvestpower.net
Tax Map District: 1000 Section: 107 Block: 07 Lot: 010
BRIEF DESCRIPTION OF WORK (Please Print Clearly)
Installation of. a 9 . 0 kW Solar PV- System w/ (25)REC360AA Roof-Mounted Panels
Check All That Apply:
Is job ready for inspection?: 2]YES ❑NO ❑Rough In [Z]Final
Do you need a Temp Certificate?: ❑YES- [Z]NO Issued On
Temp Information: (All information required)
Service Size 01 Ph ❑3 Ph Size: 200 A # Meters 1 Old Meter#
❑✓ New Service 0 Service Reconnect ❑ Underground ❑✓ Overhead
#Underground Laterals 01 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N
Additional Information:
PAYMENT DUE WITH APPLICATION
Electrical Inspection Form 2020.xlsx
PERMIT# Address:
Switches
Outlets
GFI's
r
Surface
Sconces
H H's
UC Lts
Fans Fridge HW
Exhaust Oven Dryer
Smokes DW ..Servi.ce
Carbon Micro Generator
Combo Cooktop -'Transfer-
AC
Transfer-AC AH Mini
.--Special:---
Comments:(-
-Special:-Comments:' " AA o2l-
` 7 �
�v
HARVEST POWE R
Harvest Power LLC 1 2941 Sunrise Hwy., Islip Terrace, NY 11752 Office: 631-647-3402 Fax: 631-647-3404
r_.
j VIEJune 23,2021 I =
SUN 2 s 2021
Town of Southold Lub)
Building Department y"JDUNG DEPT
P.O.Box 1179 ';V,P74.
Southold,NY 11971 `r f'_ IT R.or p
Re: Engineer's Post-Install Letter&Final Electrical Inspection Request
Hurley Residence— 1535 Westview Dr,Mattituck—BP#46310
Dear Town of Southold Building Department:
Enclosed,please find the Engineer's post-install letter and electrical inspection
application for the PV solar installation completed at the above referenced residence.
We would like to schedule the final electrical inspection at the Town's earliest
convenience. Please call me at(631) 647-3402 to schedule.
Thank you for your attention to this matter. If you need any further information, please
contact me at(631) 647-3402 or via email at jott@harvestpower.net.
Very truly yours,
Timothy Ivins
VP Administration
i
c
Licensed, insured & bonded I License # Nassau County: H0811250000 License # Suffolk County: 48165-H
e
Suffolk County Dept of
>>j Labor,Licensing&Consumer Affair
t
.. HOME IMPROVEMENT LICENSE
Name
CARLOS LANZA t
Business Name 11
This certifies that the
bearer is duly licensed Harvest power LLC
by the County of suffolk
License Number:H-48165
Rosalie Drago Issued: 11/18/2010
Commissioner Expires: 11/01/2022
V-rAa)
APPROVED AS NOTED
DATE: B.P.# OCCUPANCY OR
FEE: 4'd&2•oQBY: USE IS UNLAWFUL
NOTIFY BUILDING DEPARTMENT AT ��ITI�OUT CERTIFICATE
765-1802 8 AM TO 4 PM FOR THE
FOLLOWING INSPECTION&
1. FOUNDATION - TWO REQUIRED T OCCUPANCY
FOR POURED CONCRETE
2. ROUGH - FRAMING & PLUMBING
3. INSULATION
4. FINAL - CONSTRUCTION MUST
BE COMPLETE FOR C.O.
ALL CONSTRUCTION SHALL MEET THE
REQUIREMENTS OF THE CODES OF NEW
YORK STATE. NOT RESPONSIBLE FOR
DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF
NEW YORK STATE & TOWN CODES
AS REQUIRED AND CONDITIONS OF
SOUTHOLD TOWN ZBA -
SOUTHOLD TOWN PLANNING BOARD
SOUTHOLD TOWN TRUSTEES
N.Y.S.DEC
MWMCAL VISPOCUM REQUMM
4• y
Graham Associates 1981 Union Blvd. Bay Shore,N.Y. 11706
Building Consultants &Expeditors (631)665-9619 Fax(631)969-0115
May 6, 2021
Town of Southold
Building Department
54375 Rt. 25
Southold, NY 11971
Re: Hurley Residence
1535 Westview Drive
Mattituck, NY 11952
9.00 kWDC, 6.25 kWAC Rooftop Solar Photovoltaic Systems
To Whom It May Concern,
Please be advised that I have analyzed the existing roof structure at the
above-mentioned premises and have determined that it is adequate to
support the additional load of the solar panels and a 140 mph wind load
without overstress, in accordance with the following:
The 2020 New York State Uniform Fire Prevention and Residential Building
Code; Town of Southold Local Code, Long Island Unified Solar Permit
Initiative, (LIUSPI); and 2020 National Electric Code NFPA 70/2020
National Electric Code including ASCE7-10
If you have any further questions, do not hesitate to call.
Sincerely, � ,?,ED ARC
\5 G�PEL K.�0G y/J
��✓ �� �vv ti� ��-�
Michael K Du
OF N��1
rn..
SOLAR'S MOST TRUSTED
REC
,�N a
7�M1
� 1
i
�1
EXPERIENCE
375 REE
25 YEAR
PROTRUST
WP WARRANTY
POWER
ELIGIBLE FOR PERFORMANCE
REE ALPHA BLACK 5F_R[
PRODUCT DATASHEET
1 721t2.5[67Js±0.1.
+.28[1.11 802[31.51 455[17.91 ! CERTIFICATIONS
IEC 61215-2016,IEC 61730:2016,1JL1703,UI 61730
+ IEC 62804 PID
- 1' 000[391 IEC 61701 Salt Mist
IEC 62716 Ammonia Resistance
IS011925-2 Ignitability(Class E)
_ IEC 62782 Dynamic Mechanical Load
o* IEC 61215-2:2016 Hailstone(35mm)
v o m AS4040.2 NCC 2016 Cyclic Wind Load
■
"' � u 15014001:2004,ISO 900L2p15.OHSA5180012007,IEC62941
N
O N
CED
0 011±0.2 DyE SA° Wke�iway
[0.43±o.a]': C PUS oke e-waYEEE-compllant
� _ recYchng scheme
I
=T WARRANTY'
zos±o s . ' I ��-
[0.78±0.081 1 zoo[471 - Standard REC ProTrust
Instal
ed by an REC
r
t [Profesonal Certified No Yes Yes
Solar
System Size All 42SkW 25-500 kW
45[1.51 22.5[0.91 621±3[24.5±0.121 - -
� Product Warranty(yrs) 20 25 25
`30 0.181 power Warranty(yrs) 2S 25 25
Measurements in mm lin)
Labor Warranty(yrs) 0 25 10
GENERAL DATA Power in Year 1 98% 98% 98%
120 half-cut cells with REC StaubliMC4PV-KBT4/KST4(4mm2) Annual Degradation 0.25% 0.25% 0.2S%
Cell type: heterojunction cell technology Connectors: in accordance withlEC628S2 Power in Year 2S 92% 92% 92%
6 strings of 20 cells in series IP68 only when connected See warranty documents for details.Conditions apply.
Glass: 3.2 mm solar glass with Cable: 4mm2solar cable,1.0m+1.2m MAXIMUM RATINGS
anti-reflection surface treatment in accordance with EN 50618
Backsheet:
Highlyresistant Dimensions: 1721 x 1016 x 30 mm(1.75 mZ) Operational temperature: -40...+8S°C
polymeric construction(black) Maximum system voltage: 1000V
Frame: Anodized aluminum(black) Weight: 19.5 kg Design load(+):snow 4666Pa(47Skg/m2)'
Maximum test load(+): 7000Pa(713kg/m2)*
3-part,3 bypass diodes,I P67 rated ,
]unction box: in accordance with 1EC62790 Origin: Made in Singapore Designload(-):wind 2666Pa(272kg/m)
Maximum test load(-): 4000 Pa(407 kg/m2)'
*_- ELECTRICALDATA Product Code*:RECxxxAA Black Max series fuse rating: 2SA
Power Output-P_(Wp) 3SS 360 36S 370 375 Max reverse current: 25A
- - - -Calculated usinga safety factor of 1.5 w
Watt Class Sorting-(W) -0/+S -0/+5 -0/+S -0/+S -0/+S See installation manual for mounting instructions
t
Nominal Power Voltage-V,,,(V) 36.4 36.7 371 37.4 37.8 0
- TEMPERATURE RATINGS'
u Nominal Power Current-I (A) 977 9.82 9.85 9.9 9.94
M1PA Nominal Module Operating Temperature: 44-C(±2°C)
Ln Open Circuit Voltage-Voc(V) 43.6 43.9 44.0 44.1 442
Temperature coefficient ofPM,x: -0.26%/°C o
Short Circuit Current-I (A) 10.47 10.49 10.52 I0.SS 10.58
Is, Temperature coefficient ofVoc: -0.24%/aC
Power Density(W/m') 202.85 205.71 208.57 211.42 214.28
Temperature coefficient of Isc: 0.04%/aC
u,
Panel Efficiency(%) 20.3 20.6 20.9 21.2 21.4 'The temperature coefficients stated are linearvalues
Power Output-PMAx(Wp) 271 274 278 282 286 LOW LIGHT BEHAVIOUR
0
Nominal Power Voltage-VM,P(V) 343 34-6 35.0 352 3S.6 Typical low irradiance performance ofmoduleatSTC: o
O _ o
g Nominal PowerCurrent-1,,,,(A) 7.89 7.93 7.96 8.00 8.03
Z
Open Circuit Voltage-Voc(V) 41.1 414 41.5 41.6 416
s o
Short Circuit Current-Isc(A) 8.46 8.47 8.S0 8.52 8.55 W
Values at standard test conditions(STC:air mass AM 1.5,irradiance 1000 W/m2,temperature 25'Q based on a production spread with m
0
atoleranceof P_Vx&Ix±3%withinonewatt class.Nominal module operating temperature(NMCT:air mass AM 1.5,irradiance ,m
800W/m'.temperature20'C.windspeedIm/s).•Wherexxxindicatesthenominalpowerclass(P..)atSTCabove. �Irradiance(W/m')
REC Group is an international pioneering solar energy company dedicated to empowering ��
consumers with clean,affordable solar power in order to facilitate global energy transitions. R
t t Committed to quality and innovation,REC offers photovoltaic modules with leading high quality,
backed byan exceptional low warranty claims rate of lessthan 100ppm.Foundedin Norwayin 1996, www.recgrroup.com ...
REC employs 2,000 people and has an annual solar panel capacity of 19 GW.With over 10 GW
installed worldwide,REC is empowering more than 16 million people with clean solar energy.REC ❑� 'Q
Group is a Bluestar Elkem company with headquarters in Norway,operational headquarters in
�tl, Singapore,and regionalbases in North America,Europe,and Asia-Pacific.
•
Data Sheef
Enphase Microinverters
Regior: US
Enphase The high-powered smart grid-ready
Enphase IQ 7 MicroT" and Enphase IQ 7+ Micro'"
IQ 7 and IQ 7+ dramatically simplify the installation process while
achieving the highest system efficiency.
Microinverters Part of the Enphase IQ System,the IQ 7 and
IQ 7+ Microinverters integrate seamlessly with
the Enphase IQ Envoy", Enphase Q Aggregator'"
Enphase IQ Battery", and the Enphase Enlighten'"
monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power-on testing,
enabling Enphase to provide an industry-leading
warranty of up to 25 years.
Easy to Install
• Lightweight and simple
Faster installation with improved,lighter two wire cabling
Built-in rapid shutdown compliant(NEC 2014&2017)
Productive and Reliable
• Optimized for high powered 60-cell and 72-cell*modules
More than a million hours of testing
Class II double-insulated enclosure
UL listed
0
Smart Grid Ready
• Complies with advanced grid support,voltage and
frequency ride-through requirements
• Remotely updates to respond to changing
grid requirements
Configurable for varying grid profiles
Meets CA Rule 21 (UL 1741-SA)
UL *The IQ 7+Micro is required to support 72-cell modules.
E N P H AS E
To learn more about Enphase offerings,visit enphase.com
e
Enphase IQ 7 and IQ 7+ Microinverters
INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US
Commonly used module pairings' 235W-350W+ 235 W-440 W+
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48V 60V
Peak power tracking voltage 27 V-37 V 27 V-45 V
Operating range 16V-48V 16 V-60 V
Min/Max start voltage 22 V/48 V 22 V/60 V
Max DC short circuit current(module Isc) 15 A 15 A
Overvoltage class DC port II II
DC port backfeed current 0 A 0 A
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal(L-L)voltage/range2 240 V/ 208V/ 240 V/ 208V/
211-264 V 183-229V 211-264 V 183-229 V
Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A
Nominal frequency 60 Hz 60 Hz
Extended frequency range 47-68 Hz 47-68 Hz
AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms
Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC)
13(208 VAC) 11 (208 VAC)
Overvoltage class AC port III III
AC port backfeed current 0 A 0 A
Power factor setting 1.0 1.0
Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peak CEC efficiency 97.6% 97.6% 97.5% 97.3%
CEC weighted efficiency 97.0% 97.0% 97.0% 97.0%
MECHANICAL DATA IQ 7 Microinverter
Ambient temiperature range -40°C to+65°C
Relative humidity range 4%to 100%(condensing)
Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter)
Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket)
Weight 1.08 kg(2.38 lbs)
Cooling Natural convection-No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated,corrosion resistant polymeric enclosure
Environmental category/UV exposure rating NEMA Type 6/outdoor
FEATURES
Communication Power Line Communication(PLC)
Monitoring Enlighten Manager and MyEnlighten monitoring options.
Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break
disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
and DC conductors,when installed according manufacturer's instructions.
1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility.
2.Nominal voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings,visit enphase.com u EN PHAS E
2018-02-08
PHOTOVOLTAIC ROOF MOUNT SYSTEM
25 MODULES-ROOF MOUNTED - 9.00 kWDC, 6.25 kWAC
1535 WESTVIEW DR.MATTITUCK, NY 11952, USA. HARVEST
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
SYSTEM SUMMARY: SHEET INDEX TERRACE,NY 11752
TEL:(801)989-3585
(N)25-REC360AA(360W)MODULES PV-0 COVER SHEET website:wwwharvestpowernet
(N)25-ENPHASE IQ7-60-X-US MICRO-INVERTERS PV-1 SITE PLAN WITH ROOF PLAN
(N)JUNCTION BOX PV-2 ATTACHMENT DETAILS
(E)200A AUTOMATIC TRANSFER SWITCH WITH (E)200A MAIN BREAKER PV-3 SINGLE LINE DIAGRAM
(E)200A MAIN SERVICE PANEL WITH (E)200A MAIN BREAKER PV-4 PLACARDS&WARNING LABELS
(N)60A FUSED AC DISCONNECT PV-5 ADDITIONAL NOTES
(N) ENPHASE IQ COMBINER BOX PV-6+ EQUIPMENT SPEC SHEETS
DESIGN CRITERIA:
ROOF TYPE: -ASPHALT SHINGLE VERSION
NUMBER OF LAYERS: -01 DESCRIPTION DATE REV
ROOF FRAME: -2"X12",2"X10", RAFTERS 16" O.C.
BLDG.PERMIT osioszozl o
STORY: -SINGLE STORY
SNOW LOAD : -40 PSF
WIND SPEED :- 130 MPH
WIND EXPOSURE:- B — —
GENERAL NOTES:
1. INSTALLATION IN ACCORDANCE WITH MANUFACTURER ARRAY LOCATIONS tea` II
RECOMMENDATIONS.
2. ENGINEER TO INSPECT PROJECT AFTER INSTALLATIONPROJECT SITE ."a
AND CERTIFY COMPLIANCE. �Q
3. PROJECT TO BE INSTALLED WITH CODE COMPLIANT
RACKING INSTRUCTIONS FOR UNI-RAC SOLAR MOUNT N�VV
SYSTEM. --
4. FOLLOW BALLASTING SCHEDULE ON ROOF PLAN. '
5. HARVEST POWER, LLC_ THE SOLAR INSTALLATION �+n
CONTRACTOR, COMPLIES WITH ALL LICENSING&ALL y' O
RELATED REQUIREMENTS OF THE GOVERNING tic O
MUNICIPALITIES AND THE LOCAL ELECTRIC UTILITY 4 O
AHJ'S. �' Y O
6. THIS PROJECT WILL COMPLY WITH THE CURRENT NEC R , 0 CD
O O
REQUIREMENTS INCLUDING ARTICLE 690 SOLAR i�, } Q ti =
PHOTOVOLTAIC PV SYSTEMS. ^A ^ _ W W U CCD
D �-
7. THE ROOF WILL HAVE NO MORE THAN A SINGLE LAYER O
OF ROOF COVERING IN ADDITION TO THE SOLAR • d ' N
It—
EQUIPMENT.
O
EQUIPMENT. {, 1535 Westview Lo O C/)
8. INSTALLATION WILL BE FLUSH-MOUNTED, PARALLEL D(, Matttuck, NY... W> I~- °� o
U > =;
TO AND NO MORE THAN 6.5"ABOVE ROOF , Q �— O =
9. MAINTAIN A MINIMUM OF 18"CLEARANCE AT RIDGE ii O
AND AT ONE GABLE EAVLo }
E
� M Z
10 THIS DESIGN COMPLIES WITH 128 MPH WIND Z
REQUIREMENTS OF THE RESIDENTIAL CODE OF N J.S ��?'`
AND ASCE 7-16. ° '� a<sE _ a
11. WHEREVER THE ROOF PLAN DOES NOT COMPLY WITH Q
ACCESS AND VENTILATION REQUIREMENTS OF THE
UNIFORM CODE, HARVEST POWER PROPOSES THAT
ALTERNATIVE VENTILATION METHODS WILL BE
EMPLOYED. REVIEW AND APPROVAL SHALL BEAT THE y �,� SHEET NAME
DISCRETION OF THE MUNICIPALITY IN WHICH THIS _ _ �tQ
DOCUMENT HAS BEEN FILED. - COVER SHEET
12. THE DESIGN PLANS COMPLY WITH THENEW AERIAL PHOTO 2 VICINITY MAP
YORK STATE UNIFORM FIRE PREVENTIONN AND
RESIDENTIAL BUILDING CODE.
SCALE: NTS SCALE: NTS SHEET NUM
�r PV-0
MODULE TYPE, DIMENSIONS & WEIGHT ROOF ACCESS AREA: ;
NUMBER OF MODULES=25 MODULES SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND OVER OPENINGS SUCH AS
WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THEF
��
MODULE TYPE=REC360AA(360W)MODULES ACCESS;POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS.MODULE WEIGHT=43 LBS/19.5 KG.
MODULE DIMENSIONS=67.8"X 40.0"= 18.83 SF ���\
UNIT WEIGHT OF ARRAY=2.28 PSF
HARVESTI""ME{
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
TEL:(801)989-3585
Jo websitemww.haivestgowernet
m
VERSION
DESCRIPTION DATE REV
BLDG.PERMIT 05/05/2021 O
/'/ ♦ \\ (E)200A AUTOMATIC �OJ \��`PD�/v �
\NE ♦ �—�^ TRANSFER SWITCH WITH
Q80 E8� ��� 89•.6 ♦ ♦ ° \ (E)200A MAIN BREAKER
\ ♦ J lJ, "h
�/� • • • ° �-�IT 0298 l �O
REC360AA(3 0W) • ♦• ��� \ ®� °"
\ RAFTERS=2k10•@16.O.0 • \� \
246•AZIMUTH,18°TILT ♦ e° 1� PROJEC AME
\ (25)EN MICR IN ERTERS rF /.\.(\,\N� 0
\ MICROINVERTERS � EFt
/P80p Oc:)
O C)
Yw � [�' U)
(E)200A MAIN SERVICE
PANEL WITH(E)200A MAIN ) W v C
BREAKER L{� = O
^ iT ((E)UTILITY METER NI)
O
\ \ ✓ OUTSIDE) V^ Q
(N)60A FUSED AC U) P 5
DISCONNECT
(N)ENPHASE 10 w C
COMBINER PANEL � � Q
/ � M z
Lo
\ // (N)JUNCTION BOX z
L
'0\\\ (N)3/4EMT CONDUIT Q
RUN 1l2'ABOVE ROOF
F '
SHEET NAME
SITE PLAN WITH
SITE PLAN WITH ROOF PLAN �� ROOF PLAN
1 � SHEET NUMBER
SCALE: 1/32"= 1'-0" PV-1
i
HPk.
ENLARGE VIEW (PV-2/2)
HARVESTPO ER
HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
PV MODULES TEL:(801)989-3585
website:www.hgn! s ower.net
i
G
Fzs @1610 - .
�PF-(E (E)ASPHALT SHINGLE VERSION'-
ROOF
ERSIONROOF(TYP.) DESCRIPTION DATE REV
BLDG.PERMIT 05/05/2021 0
GENERAL NOTES: - -�
1. RAILS TO BE INSTALLED TWO PER PANELS AS SHOWN IN DETAIL. ^'
2.ALL PENETRATIONS TO BE MADE@ 48"O.C. �GjPEL K.p-
3. BOLTS TOBE INSTALLED INTO RAFTERS.
4. MINIMUM 2"PENETRATION INTO WOOD FOR CODE COMPLIANCE.
ATTACHMENT DETAIL NOTE.- ;
"ACTUAL ROOF CONDITIONS AND RAFTER(OR SEAM)LOCATIONS MAY
1 VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES
SCALE: NTS AND ENGINEERED SPANS FOR ATTACHMENTS."
yT�0oF9NJG�-.��
PROJECT NAME
PV MODULES p
O
O
O
IN I lcl� O
UNIRAC SM LIGHT RAIL w Q O' O=
L-FOOT J W U D o
FLASH KIT PRO = ~ � o O)
(E) ASPHALT SHINGLE (n F- 0) c)
ROOF (TYP.) ROOF/ DECK MEMBRANE U 3: Q =
QLo2 >- c? Q
�
Z
itZ
BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT a_
OR 2-1/2" MIN. EMBEDMENT AND SS EPDM Q
2.5 MIN. WASHER
EMBEDMENT
SHEET NAME
ATTACHMENT
DETAILS
ATTACHMENT DETAIL ENLARGE VI E1/1/ SHEET NUMBER
2 SCALE: NTS PV-2
(25) REC360AA(360W)MODULES BILL OF MATERIALS
(25)ENPHASE IQ7-60—X—US MICRO—INVERTERS
(1)BRANCH OF 13 MODULES EQUIPMENT QTY DESCRIPTION �¢
(1)'BRANCH OF 12 MODULES SOLAR PV MODULE 25 REC SOLAR REC360AA(360W)MODULES
INVERTER 25 ENPHASE IQ7-60—X—US MICRO—INVERTERS I 1p
SYSTEM SIZE:-25 x 360W= 9 kWDC COMBINER BOX 1 ENPHASE IQ COMBINER BOX
25 x 250W= 9 k DC JUNCTION BOX 1 600V,55A MAX,4 INPUTS,MOUNTED ON ROOF FOR WIRE&CONDUIT TRANSITION HARVESTPO ER
AC DISCONNECT 1 60A FUSED,40A/2P FUSE,240V NEMA 3R,UL LISTED HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
TEL:(801)989-3585
website:www.hanrestpowernet
BI-DIRECTIONAL
UTILITY METER
1-PHASE,3-W,
120V/24OV,60Hz
L �f
SUPPLY TAP VERSION
DESCRIPTION DATE REV
BLDG.PERMIT 05/05/2021 0
( 200A
iEU A/��
AUTOMATIC TRANSFER SWITCH �\��G�PEL✓< D(�� T�
W/(E)200A
MAIN BREAKER
3/4"EMT CONDUIT RUN (TOP FED)
(4)#10 AWG THWN-2
(1)#10 AWG THWN-2 GND =s —
13 MICRO-INVERTERS IN BRANCH CIRCUIT#1 (N)ENPHASE IQ ( 200A
COMBINER BOX �`. 02981/ �O�
(E)200A MAIN _nl
ENVOY CELL SERVICE PANEL ®,F
• • • tl
MODEM W/(E)200A
(N)JUNCTION (N)AC DISCONNECT: ^ MAIN BREAKER PROJ ME
BOX 0A 60A FUSED,/w 40A/2P (TOP FED)
FUSES,240V NEMA O
3R,UL LISTED, O
40Al2P FUSE O
———— —— ———— ——— 20A
IHIEM ..
O J
I 2A 0 O O
O
12 MICRO-INVERTERS IN BRANCH CIRCUIT#2 — _ _o— — — —_ —— — —— G ——— ————— J W Y j O
. . .
L--J N oIZ- p
Lo(n (n
21- �
(1)#6 BARE COPPER GND (3)#8)WG THWN-2 Y !.L I O
:P:PT—�g
(2)Q—CABLE
EXISTING Q r O
" I (1)#8 AWG THWN-2 CU GND GROUNDING Q Lo C >- �
3/4"EMT CONDUIT SYSTEM G
--J
Ch— Z
--- ------ L0
Z
Q
(25)ENPHASE IQ7-60-X-US
MICRO-INVERTER
SHEET NAME
TERMINATOR CAP ON LAST CABLE
CONNECTOR AC TRUNK CABLE(TYP) SINGLE LINE
DIAGRAM
SINGLE LINE DIAGRAM SHEET NUMBER
SCALE: NTS PV-3
I
x ,
� 4.,
� l VA�RN I N G � V-.W,,RN'I NSG _
4`
- ,
�+
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC SYSTEM SOLAR LAR PV SYSTEM EQUIPPED
TERMINALS ON LINE AND LOAD
COMBINER PANEL WITH RAPID SHUTDOWN HARVESTPOVJE
SIDES MAY BE ENERGISED IN DO NOT ADD LOADS HARVEST POWER LLC
2941 SUNRISE HIGHWAY ISLIP
THE OPEN POSITION. LABEL LOCATION: TERRACE,NY 11752
PHOTOVOLTAIC AC COMBINER(IF TEL:(801)989-3585
LABEL LOCATION: APPLICABLE). website:www.harvestpowernet
INVERTER(S),AC DISCONNECT(S),AC 3"
COMBINER PANEL(IF APPLICABLE). TURN RAPID SHUTDOWN SOLAR ELECTRIC
PV PANELS'
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYTEM AND REDUCE
SHOCK HAZARD IN THE
- . ARRAY. VERSION
• ■ SOLAR ■ DESCRIPTION DATE REV SYSTEM
BLDG.PERMIT 05/05/2021 0
LABEL LOCATION:
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
LABEL LOCATION: DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
UTILITY SERVICE ENTRANCE/METER,INVERTER/DC ARE CONNECTED. _
DISCONNECT IF REQUIRED BY LOCAL AHJ,OR
AA--
OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.
. 'r
f
�1NARNING� . I
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS "�}� X298 0
OVERCURRENT DEVICE n c �N - i�
P
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS O
OCPD(IF APPLICABLE). O
O
BUILDING SUPPLIED BY UTILITY -- 0
GRID AND PHOTOVOLTAICJ
SYSTEM w Y � o
PHOTOVOLTAIC wo ~
� V �
POWER - �i= a
_ rn 0 U)LABEL LOCATION: Ile uj H. — O
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, V < - O Q
AT EACH TURN,ABOVE AND BELOW PENETRATIONS, O
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. M Z
L Z
r
PHOTOVODISCONNECT
MAXIMUM AC-CIPERATING CURRENT. 25 AMPSo
NOMINALOPERATING AC VOLTAGE:
SHEET NAME
LABEL LOCATION:
PLACARDS AND
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF w EPµa
INTERCONNECTION. WARNING LABLES
SHEET NUMBER
LABEL LOCATION:
POINT OF INTERCONNECTION PV-4
(PER CODE:NEC690.56(B),NEC705.10,225.37,230.2(E))
1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER
MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND
METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING t
ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, HARVEST � 9�
IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL
GROUNDING ELECTRODE. 2941 SUNRSE IG WAYIS IP
TERRACE,NY 11752
TEL:(801)989-3585
2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL websitemwwhan2gg wer net
ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR
MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL
BE UV RESISTANT IF EXPOSED TO SUNLIGHT.
3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC
CIRCUIT" OR EQUIV. EVERY 5 FT. VERSION
DESCRIPTION DATE REV
4. EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT BLDG.PERMIT 05/05/2021
SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A).
5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO
CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER
Svc 2
VOLTAGE OPERATIONAL RANGE. 44i'
t Cp
6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER.
N Zvi
7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND �� 02981-, yp
ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. T Ir-
PR
8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL o
MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED o
SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELP OFF OF THE o
ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 o
9. ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT w Y o O
_j Luo Do �
SUFFICE. j N o O
U3: Q `- C) _
< V) OK- Q
ct) Z
Lo
�- Z
CL
Q
SHEET NAME
ADDITIONAL
NOTES
SHEET NUMBER
PV-5
HARVESTPOtIVER
HARVEST POWER l
ll2941 SUNRISE HIGHWAY ISLIP
TERRACE,NY 11752
'.
I 1'. •.
SO'LARMOUNT UNIRAC •o
`p
r ' � 1 1 1 1 1 1' • I � .11 1 �•'
1• •1 1 •. 1 1• , 1 1 • ,� 1 1 BETTER DESIGNS
• 1• 1 1 r ,• , , 1 TRUSTTHE INDUSTRY'S BEST DESIGN TOOL CONCEALED.UNIVERSAL
Start thegslgn process for every project in our Uuildor online design toot. ENDCLAMPS
1 1 1 1 It s a greal�ylay to save lime and:moncy.I'm IND ® •
BETTER SYSTEMS ,
BLDG.PERMIT
ONE SYSTEM-MANY APPLICATIONS
Quickly se)modules flush to the roof on"steep pitchetl coats•Onent a large varfely F __
of module, in Portrait or Landscape.Tilt the system up on flat or low slow roots. END CAPS INCLUDED ®®_
Componeo• available in mill,clear.and dark finishes tooptimize your desrgntmancials WITH',EVERY ENDCLAMP
I andaesthe#"es= ' A
BETib RESULTS
MAXIMIZE PROFITABILITY ON EVERY JOB,
-
UNIVERSAL, I Trust Unir�cllo help you minimize both system and lahorcosts 11011111101111111!Nle iutl Ts, .
CLAMPS quoted to thu limoyour teams got off the roof.Faster installs-Less Wasle.More Profits, 6
UNIVERSAL SELF ;
FUNIRAC i BETR SUPPORT STANDING MIDCLAMPS •
25WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM
Professfoffaft'sop port for professional installers and designers.You have access to
our techri I support and training groups.Whatever. atever your support needs.We ve got
1 '1 OPTIONAL r CH you covefavIsrtUolrac.eomfsolarmount for more information. , • •
. � � � r � FRONT TRIM `fUIE-SY31EM 'r' � � � �• }
WAflflAlI1Y 9a
U BUILDER ONLINE DESIGN •
TOOL SAVES TIME&MONEY
io, 3 c Laat,`_ Zvi
80NDIN0,&GROUNDING r_____� we;6��w Visit des{gp un'rrac.uom
MECHANICAL LOADING j C
ff UL2703 __ :.�.
. . SYSTEMFIRECLASSIfICATIOfJ - � � C
o t 0
w CD
UNI CC USTOMER SERVICE MEANS THE HIGHEST LEVEL Of PRODUCT SUPPORT
z •
W CD
r� •
UNMq CNED CERTIFIED ENGINEERING BANNAGLE DESIGN' t, PERMIT � �
1 r '11 ' 1 1 ' 1 II. I 11 1 •1 1 • 1 I.1 I ,1 EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS ! OODUMENIATION
1 II 1 I' 1
TECHNICA SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARPANTY
LIR4 slec(ihical.supportteamisdedicatedtoanswering Uniracisthe only PVmounlingvendor'WithISO Don't leave your project tochance.Umrachasthe
questions&pddressmgIssues inreal time.Anonline certifications lot 909112008,14001.2004and OHSAS financial strength to back our products and reduce your risk.
library ofdocumentsincludingengineering reports, 18001.2001,which means via deliver thribighestslandards Havepeaceofmind knowingyou oraprovidingproductsaf
THE PROFESSIONALS CHOICE FOR RESIDENTIAL RACKING stamped lowrsand technical data shoots greatly for lil.farm,and function.These car Iii ficalionsdemomstrato exceptional`quality.SOlARMOUNTiscoveredbya25year
simplifiesyrnipermilting and prolectplanning proces% out excellence-and commitment toNADI=business practices, limited productWarranyyarnda5yeariimitedfinishtivarranty.
111111ItI 111111111111111111 II II 1111111A11 ..........111111111111111111111111U111111111111(IIIYIIIII1111111 Illilt 111111 111111111111111 Irll1111 1i1111111r1,-11111it 111)1111111j1111111 11111111111111111111111 1111111111111111111111111111,1 IIIIIIY11111.111111 111)1111111. L'.
4
BEST INSTALLATIONEXPERIENCE•CURB APPEAL•COMP LETESOLUTION0UNIRAO SUPPORT SHEET NAME
ENHANCEYOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND SUPERIOR SUPPLY CHAIN
FOR QUESTIONS OR CUSTGMER SERVICE_ VISIT UNIR.AC.COM OR CALL (505) 248;2702 pt o>�_EIpr1EBQ?CAIT FOR QUESTIONS OR C-'USTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 SPEC SHEET
f
SHEET NUMBER
PV-
tr+
•
,!!r,/ft
HAWESTPOWE
HARVEST POWER LLC
Pz 2941 SUNRISE HIGHWAY ISLIP
structural TERRACE,NY 11752
ENGINEERS ENGINEERS
R I TEL:(801)vestpo 5
ENGINEERS website:www.harvestpower.net
October 23,2020
Unirac Components and Cladding Roof Zones:
1411 Broadway Blvd.NE The Components and Cladding Roof Zones shall be determined based on ASCE 7-05,ASCE 7-10&7-16 Component and
Albuquerque,NM 87102
Cladding design.
Attn.:Unirac-Engineering Department. Notes: 1)U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not
include roof capacity check. VERSION
Re:Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail 2)Risk Category II per ASCE 7-16. DESCRIPTION DATE REV
3)Topographic factor,kzt IS 1.0. BLDG.PERMIT 05/05/2021 0
PZSE,Inc.-Structural Engineers has reviewed the Unirac SOLARMOUNT rails,proprietary mounting system constructed 4)Array Edge Factor YE=1.5
from modular parts which is intended for rooftop installation of solar photovoltaic(PV)panels;and has reviewed the U- 5)Average parapet height is 0.0 ft.
builder Online tool.This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail,SOLARMOUNT 6)Wind speeds are LRFD values.
STANDARD rail,and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information,data and 7)Attachment spacing(s)apply to a seismic design category E or less. ��Lt=� AAIC
analysis contained within are based on,and comply with the following codes and typical specifications: \�� PEL K.p��
Design Responsibility: `C' :mss✓ �'
1. Minimum Design Loads for Buildings and other Structures,ASCE/SEI 7-05,ASCE/SEI 7-10,ASCE/SEI 7-16 Lc,
The U-Builder design software is intended to be used under the responsible charge of a registered design professional
2. 2006-2018 International Building Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2 2017. n
where required by the authority having jurisdiction.In all cases,this U-builder software should be used under the _{�
3. 2006-2018 International Residential Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2
2017. direction of a design professional with sufficient structural engineering knowledge and experience to be able to:
4. AC428 Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic PV Panels November Evaluate whether the U-Builder Software is applicable to the project,and
p g Y PP ( ) PP P J t3� �
1,2012 by ICC-ES. ft
Understand and determine the appropriate values for all input parameters of the U-Builder software. -9� 0291 ,�
5. 2015 Aluminum Design Manual,by The Aluminum Association,2015 � �
This letter certifies that the Unirac SM SOLARMOUNT Rails Flush,when installed according to the U-Builder engineering PRO-3 7,;
Following are typical specifications to meet the above code requirements: report and the manufacture specifications,is in compliance with the above codes and loading criteria.
O
Design Criteria: Ground Snow Load=0-100(psf) O
This certification excludes evaluation of the following components: O
Basic Wind Speed=85-190(mph) O
Roof Mean Height=0-60(ft) 1) The structure to support the loads imposed on the building by the array;including,but not limited to:strength O I0
Roof Pitch=0-45(degrees)
and deflection of structural framing members,fastening and/or strength of roofing materials,and/or the effects11:1O J
of snow accumulation on the structure. Q O 0
Exposure Category=B,C&D ti =
2) The attachment of the SM SOLARMOUNT Rails to the existing structure. W ! U) O
Attachment Spacing: Per U-builder Engineering report. 3) The capacity of the solar module frame to resist the loads. _J W O
Cantilever: Maximum cantilever length is L/3,where"L"is the span noted in the U-Builder online (-' C\ ~ O
This requires additional knowledge of the building and is outside the scope of the certification of this racking system. _ L0 O W
tool. Y W �_ O
Clearance: 2"to 10"clear from top of roof to top of PV panel. If you have any questions on the above,do not hesitate to call. � V � < O Q
Tolerance(s): 1.0"tolerance for any specified dimension in this report is allowed for installation. Prepared by: `�\ `�of LO��s/y//�% M Z
PZSE Inc.-Structural Engineers Z
Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. g _ * r-
Landsca e-PV Panel Ion dimension is parallel to rid a/eave line of roof and the PV Roseville,CA _ _ a
P g P g = PAUL K.ZACHER
panel is mounted on the long side. = License No.39665 Q
/2021
Portrait-PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel
is mounted on the short side. _11N 67ONALOAG�
SHEET NAME
1478 Stone Point Drive,Suite 190, Roseville,CA 95661 SPEC SHEET
1478 Stone Point Drive,Suite 190, Roseville,CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com 2 oft
T 916.961.3960 F 916.961.3965 W www.pzse.com 1 oft Experience i Integrity I Empowerment
Experience I Integrity I EmpowermentSHEET NUMBER
i
PV-7