Loading...
HomeMy WebLinkAbout47046-Z �SUFFOIK�oG Town of Southold 12/11/2021 0 y� P.O.Box 1179 o • 53095 Main Rd Southold,New York 11971 �a CERTIFICATE OF OCCUPANCY - No: 42618 Date: 12/11/2021 THIS CERTIFIES that the building ALTERATION Location of Property: 1890 Arshamomaque Ave, Southold SCTM#: 473889 Sec/Block/Lot: 66.-2-46 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 10/15/2021 pursuant to which Building Permit No. 47046 dated 10/27/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"central air conditioning to existing single family dwelling as applied for The certificate is issued to Ball,Thomas&Barbara of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 47046 11/15/2021 PLUMBERS CERTIFICATION DATED Antori deture o�gUFFO(KCo TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 47046 Date: 10/27/2021 Permission is hereby granted to: Ball, Thomas PO BOX 1708 Southold, NY 11971 To: Legalize as-built central AC system at existing single family dwelling as applied for. At premises located at: 1890 Arshamomague Ave, Southold SCTM #473889 Sec/Block/Lot# 66.-2-46 Pursuant to application dated 10/15/2021 and approved by the Building Inspector. To expire on 4/28/2023. Fees: AS BUILT-ACCESSORY $400.00 CO-ADDITION TO DWELLING $50.00 Total: $450.00 Building Inspector SO(/Tyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G� a sean.devlinCa)town.southold.nv.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Thomas Ball Address: 1890 Arshamomaque Ave city:Southold st: NY zip: 11971 Building Permit#: 47046 Section: 66 Block: 2 Lot: 46 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Home Owner License No: SITE DETAILS Office Use Only Residential X IndoorX Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 1 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 1 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 1 Switches 4'LED Exit Fixtures Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " AC s Inspector Signature: a Date: November 15, 2021 S.Devlin-Cert Electrical Compliance Form ti���OF SO4lHp6 L4 -10 `L N *©* TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST ' [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] -FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION- [- ] FIRE•RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [�Q ELECTRICAL (FINAL)- [ ] CODE VIOLATION [(( ] PRE C/O REMARKS: L-f A :r/ DATE INSPECTOR -o � {� �Not�Souryo ��� TOWN-OF SOUTHOLD BUILDING DEPT. "roam 765-1802 r INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND 1. 11 Jl SULATIOWC�AULKIN [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION _ [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 9 ZVAZ yfl�__ 06.. r , v c - DATE INSPECTOR, ��' "�k FIELD INSPECTION REPORT 'DATE COMMENTS r FOUNDATION(1ST) ------------------------------------- FOUNDATION(2ND) z OC ° 0 ROUGH FRAMING& 1 PLUMBING r � S INSULATION.PER N.Y. y STATE ENERGY CODE t h FINAL DITIONAL COMMENTS D 24 d � m . O H . CC ' d ro H o�50FFa(,F�oG TOWN OF SOUTHOLD-BUILDING DEPARTMENT x Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 hitps://www.southoidtownnv.jzov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only ` PERMIT N0. 7 Building Inspector: \}� REMMED OCT 15 2021 Applications and forms must be filled out in their entirety. Incomplete applications will not be accepted. Where the Applicant is not the owner,an BUILDING DEPT. Owner's Authorization form(Page 2)shall be completed. TOWN OF SOUTHOLD Date: IC) 1'5'12.Z)2- 1 OWNER(S)OF PROPERTY: L Name: I Y )OfY14S ��QL11 SCTM# 1000- Project Address: dress:-mo Arshrtmo . :pe. 4ve--,_ qflntA- NN/ I l l Phone#: _ 35 4 v Email: -bh b o n 1►n e.ne Mailing Address_ CONTACT PERSON: Name: OmQ Q Mailing Address: a� CkS � 0 Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: ovna.'5 \ Mailing Address: gZLvYle tT cil.b6L)E' f, Phone#: Email: 1 t(� DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition KAlteration ❑Repair ❑Demolition Estimated Cot of Project: ❑Other $ Will the lot be re-graded? []Yes �No Will excess fill be removed from premises? ❑Yes ONO Air &Y-1dr6 er 5ery i cp as bu► I-F- 1 PROPERTY INFORMATION J I , Existing use of property: Intended use of property: (r C01 Lf((7Bvtl✓1 - Llh Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes XNo IF YES, PROVIDE A COPY. Check Box Atter Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION 15 HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal law. Application Submitted By(print name): -Rmm a5 TAA I ❑Authorized Agent Owner - - ----- -- - - - -- -- - -- - - - - -- --- - - ----- - Signature of Applicant: _-- �- Date: .2 STATE OF NEW YORK) COUNTY OF Stkt't ) / r /om s a I I being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing g contract) above named, (S)he is the (�or4mC4f— O1.1Y -r-?-- (Contractor, ems(Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 15 41 day of DGI ok-)Ccs 202J Notary Public TRACEY L. DWYER NOTARY PUBLIC,STATE OF NEW YORK PROPERTY OWNER AUTHORIZATION NO.01 DW6306900 (Where the applicant is not the owner) QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2D2a- I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 ��gpFFO�,Y�o BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C3 ` Town Hall Annex - 54375 Main Road - PO Box 1179 CIO • Southold, New York 11971-0959 y o� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(@southoldtownny.gov- seand(@southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: /o 1,r—.2 Company Name: 7—X c,a/' /A// Electrician's Name: Z:e/ License No.: 21--2 v ,: Elec. email: 7'IY/1//p o,or, /,., . 7e7— Elec. Phone Nor7/ 7G y��y 01 request an email copy of Certificate of Compliance Elec. Address.: aX y-rlomc,,»a ,, JOB SITE INFORMATION (Ali Information Required) Name: Thom&.5 Address: ,Fivior-nallie Ail Cross Street: Phone No.: 3 )- 5- 436 Bldg.Permit#: 0 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): SCft-(,A n ec?— (� r-VirC .e C ax 4, T I Square Footage: Circle All That Apply: Is job ready for inspection?: YES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A # Meters Old Meter# ❑New Service[-]Fire Reconnect❑Flood Reconnect[-]Service Reconnect❑Underground❑Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y FN Additional Information: PAYMENT DUE WITH APPLICATION ��pZSr SUFFO(,� BUILDING DEPARTMENT- Electrical Inspector h�0� C�Gy TOWN OF SOUTHOLD e Town Hall Annex - 54375 Main Road - PO Box 1179 G • Southold, New York 11971-0959 'y O� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr o)southoldtownnyaov — seandCa)southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: /o,�—2 Company Name: T�.ryaA// f=/ L /0Mhi�H Electrician's Name: ,,��, License No.: 2 .f--2 o Elec. email: T`ly/f// upTo /,., . .7,e7— Elec. 7e7— Elec. Phone Nor7/ �� yp�y ❑I request an email copy of Certificate of Compliance Elec. Address.: JOB SITE INFORMATION (All Information Required) Name: p Q I Address: yylp q e , Cross Street: Phone No.: . 3 - 5- 3 BIdg.Permit#: C) email: Tax.Map District: 1000 Section: Block: Lot: BRIEF DEftSCRIPTION OF WORK, INCLUDE SQUARE FOOTAGE (Please Print Clearly): fCc,nnrc,7'-- e,y-V rc e 006,r /f-C ax 4f CT Square Footage: Circle All That Apply: Is job ready for inspection?: LaYES ❑ NO ❑Rough In ❑ Final Do you need a Temp Certificate?: ❑ YES ❑ NO Issued On Temp Information: (All information required) Service Size❑1 Ph❑3 Ph Size: A #Meters Old Meter# ❑New Service[—]Fire Reconnect[]Flood Reconnect❑Service Reconnect❑Underground❑Overhead # Underground Laterals 1 F12H Frame Pole Work done on Service? Y FIN Additional Information: PAYMENT DUE WITH APPLICATION 10DZ5r �� OZ l Z �� 144 s� OCCUPANCY OR APPROVED AS NOTED USE IS UNLAWFUL DATE:L09�d-L B.P.# &0& WITHOUT CERTIFICATE FEE: BY: OF OCCUPANCY NOTIFY BUILDING DEPARTMENT AT 755-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.Q. COMPLY WITH ALL CODES OF ALL CONSTRUCTION SHALL MEET THE NEW YORK STATE & TOWN CODES AS REQUI D AND CONDITIONS OF REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR SOUTHOLDTOWNZBA DESIGN OR CONSTRUCTION ERRORS. SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y.S.DEC Additional Certification May Be Required. a='MCALMSPWnON 1�gUMM . . Infinity" 17 2—Stage Air Conditioner with O Refrigerant Carrier 2 to 5 Nominal Tons turn tothe expertso Product Data INDUSTRY LEADING — FEATURES / BENEFITS Efficiency • 14- 18 SEER l 117 EER • Microtube Technologyogy'"- refrigeration system IIIIIIIIIIIIIIIIIIIIIII�lllllillllllllllllllllllllllllll�I • Indoor air quality accessories available So Illlllllllllllllllnllllllllllllllllllllpllllllllllllll>II� und 'IIIIIIIIIIIIIIIN � • Sound level as low as 69 dBA IIIIIIIIIIIIIiIII111111N� • Quiet mount split post compressor grommets IIIIIIIIIIIIIIII Illllllllllilllllllllllll�; • Forward-swept condenser fan blade 11111111111111111111111111NINIll111111111 • Compressor sound hood �Illlllllllll� • Laminated steel compressor mounting plate IIIHIIIIIIIIIIIIINNINNIp�IIlllnlilllll111U11� • 8 pole PSC ball bearing outdoor condenser fan motor Co IIIIHII@IpIIIIIINII►IIIIIIIIIIIIIIIIIINIIIIIIIIII�i mfort • System supports Infinity- Control or standard 2-stage INIIIINIIIIIIIIINIINIINIIIIIIIl111Nllllllllllthermostat controls Reliability _ bility -�� • Puron® refrigerant - environmentally sound, won't deplete the ozone layer and low lifetime service cost. • Front-seating service valves • 2-stage scroll compressor INFINITY. CER 1:E S • Internal pressure relief valve • Internal thermal overload Carrier's Air Conditioners with Purono refrigerant provide a • Low pressure switch collection of features unmatched by any other family of • High pressure switch equipment. The 24ANB7 has been designed utilizing Carrier's Peron refrigerant.The environmentally sound refrigerant allows Filler drier you to make a responsible decision in the protection of the earth's • Crankcase Heater standard ozone layer. Balanced refrigeration system for maximum reliability This product has been designed and manufactured to meet Controls and Diagnostics Energy Star© criteria for energy efficiency when matched with . Infinity- control (Dedicated A,B,C,D only) appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy Star® • Utility Interface Connection guidelines. • Up to 18 point diagnostic capability Durability NOTE: Ratings contained in this document are subject to WeatherArmor- protection package: change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings Solid,Durable sheet metal construction information. • Steel louver coil guard • Baked-on,complete outer coverage, powder paint Applications • Long-line - up to 250 feel (76.2 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser(See Longline Guide for more information.) • Low ambient (down to 0°F) with complete Infinity system. MODEL NUMBER NOMENCLATURE 1 2 3 4 6 6 7 a 9 10 11 12 13 N N A A AIN N N N AM AM AM N N 2 4 A N B 7 3 6 A 0 0 3 0 Product Product Tier Major SEER Cooling Variations Open Open Voltage Minor Series Family Series Capacity Series 24=AC A=RES AC N=Infinity B=Puron 7=17 A=Standard O=Not O=Not 3=2081230-1 0.1.2... SEER Defined Defined Nominal Pu®n- Use of the AHRI Certified c &us m Mark indicates e manufaation In " Thls o�educt hes Been deslgneo end menWuturetl to participation In the ,neer sne.oY sm,m atarlalw Wldew.yvmen program Forverlfication mrtWeE mN epproplelectil oomponenb.lbrc.er, of ceniflcallon for IndMdual poper reMgmant aarg.ena por!rt dr nn«encnum products,go to ISO 9001 ttdt btlJere rated croev+Nm.tl elfitlenry.IMmletlonm w .ahridirectorycrg. weamea Wwldtmowen manulecwnnp.mdpwem 0M4S441 Global � Wes^o uNar llwiilRibuv'lim4 FellYN le eon(Ilm epmpv,an0 dWarton.anevlmry reauce anergy Mclenry equipment eto. STANDARD FEATURES Unit Size —Voltage,Series FEATURES 24-30 36-30 48-30 60-30 Puron Refrigerant X X X X Maximum SEER Rattling* 17.0 18.0 17.5 16.8 2—Stage Scroll Compressor X X X X Crankcase Heater w5emperature Switch X X X X Lang line Capability X X X X Low Ambient Capability to OeF(-17.8eC)w/Infin'Ity Control X X X X Enhanced Diagnostics w/Infinity Control X X X X Utility Interface Connection X X X X Louvered Coil Guard X X X X Field Installed Filter Drier X X X X Front Seating Service Valves X X X X Internal Pressure Relief Valve X X X X Internal Thermal Overload X X X X Long Line capability X X X X Low Pressure Switch X X X X High Pressure Switch X X X X Sound Blanket X X X X X=Standard 'With approved combinations 2 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Puron®Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. Sec Table below for liquid line sizing and maximum lengths Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Size Liquid Line Line Vertical Separation ft(m) Connection Diam. 0-5 6-10 11-20 21-30 31-40 41-50 51-60 61-70 71-80 WfW (0-1.5) 1.B-3.0 (3.4-6.1) (6.4-9.1) (9.4-122) (12.5-152) (155-18.3) (18.6-21.3) (21.6-24.4) 024 1/4 75 75 75 50 50 -- -- -- -- AC with 3/8 5/16 250' 250• 250• 250' 250• 225• 175 125 100 Puron 3/8 250' 250• 250' 250' 250• 250• 250' 250' 250' 036 5/16 175 150 150 100 100 100 75 -- -- AC with 3/8 Puron 3/8 250' 250' 250` 250' 250• 250' 250• 250' 250' 048 AC with 3/8 3/8 250' 250• 250• 250• 250• 250' 230 160 -- Puron 060 AC wdh 3/8 3/8 250' 250' 250' 225' 190 150 110 -- -- Puron • Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fining.See the Long Line Guideline for details. --=outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Size Liquid Line Line Vertical Separation It(m) Connection Dlam. 25 26-50 s1-75 76-100 101-125 126-150 161-175 176-200 wrw ,6 .9-15.2 15.5-22.9 23.2-30.5 (30.8-38.1 (38.4-0.5.7 (46.0-53.3 53.6-61.0 024 1/4 100 125 175 200 225' 250• 250• 250' AC with 3/8 5/16 250• 250• 250' 250' 250• 250' 250' 250' Puron 3/8 250' 250' 250• 250• 250• 250' 250' 250• 036 5/16 225' 250' 250' 250' 250• 250• 250• 250• AC with 3/8 Puron 3/8 250' 250• 250' 250' 250' 250' 250' 250• 048 AC with 3/8 3/8 250• 250' 250' 250' 250' 250• 250' 250' Puron 060 AC with 3/8 3/8 250• 250' 250• 250' 250• 250' 250' 250' Puron •Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Lang Line Guideline for details. REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft(g/m) 3/8 0.60(17.74) (Factory charge for lineset=9 oz/266.16 g) 5/16 0.40(11.83) 114 0.27(7.98) Units are factory charged for 15 ft(4.6 m)of 3/8"liquid line. The factory charge for 3/8"lineset 9 oz.(266.16 g). When using other length or diameter liquid lines,charge adjustments are required per the chart above. Chareine Formula: [(Lineset oz/ft x total length)-(factory charge for lineset)]=charge adjustment Example 1:System has 15 ft of line set using existing 1/4"liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft)-(9 oz)=(4.95)oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16'liquid line.What is the charge adjustment? Formula: (.40 oz/ft.x 45ft)-(9 oz.)=9 oz. Net result is to add 9 Oz of refrigerant to the system 3 LONG•LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter,actual length of the tubing,and vertical separation between the indoor and outdoor units. For Air Conditioner systems,the chart below shows when an application is considered Long Line. AC WITH PURONO REFRIGERANT LONG LINE DESCRIPTION ft(m) Beyond these lengths,long line accessories are required Liquid Line Size Units On Some Level Outdoor Below Indoor Outdoor Above Indoor 1/4 No accessories needed within allowed No accessories needed within allowed 175(53.3) lengths lengths 5/16 120(36.6) 50(15.2)vertical or 120(36.6)total 120(36.6) 3/8 80(24.4) 35(10.7)vertical or 80 24.4 total 80(24.4) Note: See Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses-Puron®Refrigerant 2-Stage Air Conditioner Applications Maximum Cooling Capacity Loss(%) Unit Liquid Vapor Line Total Equivalent Line Length ft.(m) Nominal. Line Diameters Size(Btuh) Diameters (In.)OD 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (In.OD) (7.9-15.2) (155-24.4) (20.7-30.5) (30.8-38.1) (36A-45.7) (46.0-50.3) (63.9-60.0) (61.3-68.6) (69.9-76.2) 024 5/8 0 1 5 2-Stege 3/8 Puron AC 3/4 0 0 M M M M�. 1 036 5/8 1 2 4 _�5, 6 MOM WE= 2-Stage 3/e 3/4 0 0 '] 0 0 3 Puron AC 7/8 0 0 0000vvo 048 3/4 1 2K2jM t» Y-Stage 3/8 7/8 0 1 Puron AC 1-1/8 0 0 060 3/4 1 2 11 2-Stege Puron 3/8 7/8 0 1 0 0 0 5 Ac 1 1 1-1/8 0 0 . . .ou,Mft ME :,_: Applieabil-m"is-area'i51'ay h�''tbnp'tfh6'3nd may fiave helafitiestric6ons�See,uie'Resldendal P,ipingvgLong, +1-MonsGne Guideline. -/pp 1- o'�his area are not recommen a m due osu` en of reurn PHYSICAL DATA UNIT SIZE-VOLTAGE,SERIES 24-30 36-30 48-30 60-30 Operating Weight Ib(kg) 223(101) 274(124) 1 298(135) 1 351 (159) Shipping Weight lb(kg) 274(124) 1 309(140) 1 341(155) 397(180 Compressor Type 2-Stage Scroll REFRIGERANT Puron (R-410A) Control TXV(Puron Hard Shutoff) Charge Ib(kg) 6.63(3.01) 10.83 4.91) 1 11.63(5.27) 15.13(6.86) COND FAN Propeller Type,Direct Drive Air Discharge Vertical Air OTy(CFM) 3008 3530 4650 4800 Motor HP 1/10 1/5 1/4 1/4 Motor RPM 800 800 800 800 COND COIL Fete Area(Sq h) 21.56 21.56 25.15 30.18 Fins per In. '25_ 20 20 20 Rows 1 2 2 2 Circuits 5 7 7 8 VALVE CONNECT.(In.ID) Vapor 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES(In.OD Rated Vapor- 3/4 7/8 1-1/8 1-1/8 Liquid 3/8 !Un is are rated with 25 h(7.6 m)of lineset length. See Vapor Line Sting and Cooling Capacity Loss table when using other sizes and lengths of lineset. 4 ELECTRICAL DATA MIN MIN MAX MAX MAX Unit Size- OPER VOLTS' COMPR FAN WIRE WIRE LENGTH LENGTH FUSE'*or Voltage, V/PH MCA SIZEt SIZEt ft(m)$ ft.(m)$ CKT BRK Series MIN MAX FLA LRA FLA 60°C 75°C 60°C 75°C AMPS 24-30 208/230 10.3 52.0 0.7 13.6 14.00 14.00 58(17.7) 55(16.8) 20 36-30 208/230 187 253 16.7 82.0 0.94 21.8 12.00 12.00 57(17.4) 54(16.5) 35 48-30 208/230 21.2 96.0 1.3 27.8 10.00 10.00 71 (21.6) 68(20.7) 40 60-30 208/230 23.0 118.0 1.3 30.1 8.00 10.00 103(31.4) 63(19.2) 50 •Permissible limits of the voltage range at which the unit will operate satisfactorily t If wire is applied at ambient greater than 30°C,consult table 310-16 of the NEC(NFPA 70). The ampacity of non-metallic-sheathed Cable(NM),trade name ROMEX,shall be that of 60°C conditions,per the NEC(NFPA 70)Article 336-26.It other than uncoated(no-plated),60 or 750C insulation,copper wire(solid wire for 10 AWG or smaller,stranded wire for larger than 10 AWG)is used,consult applicable tables of the NEC(NFPA 70). # Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%. *•Time-Delay fuse. FLA -Full Load Amps LRA -Looked Rotor Amps MCA -Minimum Circuit Amps RLA -Rated Load Amps NOTE:Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2010 requirements of ASHRAE Standards 90.1 A-WEIGHTED SOUND POWER (dBA) r Unit Size- Standard Rating Typical Octave Band Spectrum(dBA,without tone adjustment) Voltage,Series (dBA) 125T 250 500 1000 2000 4000 8000 24-30 70-lowstage 56.5 58.5 65.0 64.5 61.0 57.0 50.5 71-high stage 54.5 58.0 65.5 65.0 62.5 58.0 55.0 36-30 69-lowstage 55.0 61.0 64.0 63.5 60.0 54.5 48.5 71-high stage 53.5 60.5 64.5 66.0 60.0 55.5 52.0 48-30 72-low stage 54.5 63.5 65.5 66.0 60.5 57.5 51.5 72-high stage 55.0 63.5 65.5 66.0 60.0 58.0 54.0 72-low stage 60.0 65.5 66.5 65.5 60.5 58.0 51.5 60-30 72-high stage 60.0 63.5 64.5 65.0 60.0 57.5 52.0 NOTE:Tested in accordance with AMR[Standard 270-08.(Not listed with AHRQ. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-VOLTAGE,SERIES REQUIRED SUBCOOLING°F(°C) 24-30 8(4.4) 36-30 13(7.2) 48-30 11 (6.1) 60-30 12(6.7) ACCESSORY CONTROLS PART NUMBER DESCRIPTION SYSTXCCUID01-V Infinity Control Deluxe 7-Day Programmable(4-Wire User Interface w)multiple functionality) SYSTXCCUIZ01-V Infinity Control Deluxe Zoning 7-Day Programmable(Wall-mounted control for a multi-zone system.w/mul- tiple functionality) SYSTXCCUID01-B Infinity Control Deluxe 7-Day Programmable(Wall-mounted system control.) SYSTXCCUIZ01-B Infinity Control Deluxe Zoning 7-Day Programmable(Wall-mounted control for a multi-zone system.) SYSTXCC4ZC01 Infinity 4-Zone Damper Control Module(Wall-mounted control for a four-zone system.) SYSTXCCSMS01 Infinity Smart Sensor(Optional wall control used to monitor temperature and/or fan control in an individual zone.) SYSTXCCRRS01 Infinity Remote Room Sensor(Monitors temperature in an individual zone.) SYSTXCCRor SYSTXCCRWF01 Infinity System Remote Access Module(Hardware for wireless access and control via internet.) WF0 SYSTXCCNIM01 Infinity Network Interface Module(Connects Heat Recovery and Energy Recovery Ventilators on non-zoning applications.) 5 ACCESSORIES ORDER NUMBER DESCRIPTION 24-30 36-30 48-30 60-30 KSAHS2301AAA HARD START KIT X KSAHS2401AAA HARD START KR X KSAHS2501AAA HARD START KR X KSAHS2601AAA HARD START KR X KSASF0101AAA SUPPORT FEET X X X X KSATX0201PUR TXV PURON HSO X KSATX0301PUR TXV PURON HSO X KSATX0401PUR TXV PURON HSO X KSATX0501PUR TXV PURON HSO X x=Accessory ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR LONG LINE AP- REQUIRED FOR SEA COAST ACCESSORY LOW-AMBIENT COOLING PLICATIONS' APPLICATIONS(Within2 APPLICATIONS (Below 55°F/12.8°C) (Over 80 ft/24.38 m) miles/3.22 km) Cmnkwse Heater Standard Standard Standard Standard with Infinity-Control Evaporator Freeze Protection (Low Ambient not allowed with No No ra non-communicating thermostat) Liquid-Line Solenoid Valve No No No Standard with Infinity Control Low-Ambient Control (Low ambient not allowed with No No non-communicating thermostat) Puron Refrigerant Balance Port Hard- Yest Yest Yest ShutOB TXV Support Feet Recommended No Recommends Standard with Infinity Control Winter Start Control (Low Ambient not allowed with No No non-communicating thermostat) • For tubing set lengths between 80 and 200 ft.(24.38 and 60.96 m)horizontal or 35 ft.(10.7 m)vertical differential(total equivalent length),refer to the Long Line Guideline-Air Conditioners and Heat Pumps using Puron®Refrigeram. t Required on all Indoor units.Standard on all new Puron refrigerant fan coils and furnace coils. Accessory Description and Usage (Listed Alphabetically) 1.Compressor Start Assist-Capacitor and Relay 3.Support Feet Start capacitor and relay gives a "bard" boost to compressor Four stick-on plastic feet that raise the unit 4 in. (101.6 mm) motor at each start up. above the mounting pad.This allows sand, dirt,and other debris Usage Guideline: to be flushed from the unit base,minimizing corrosion. Not required on this unit since compressor always starts Usage Guideline: unloaded. Suggested in the following applications: Available if required by local codes. Coastal installations. 2.Crankcase Heater Windy areas or where debris is normally circulating. An electric resistance heater which mounts to the base of the Rooftop installations. compressor to keep the lubricant warm during off cycles. For improved sound ratings. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. 4.Thermostatic Expansion Valve(TXV) Usage Guideline: A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the Required in low ambient cooling applications. refrigerant gas leaving the evaporator. Required in long line applications. Kit includes valve, adapter tubes, and external equalizer tube. Suggested in all commercial applications. Hard shut off types are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations.Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. 6 DIMENSIONS - ENGLISH UNIT SEMS CAL CHABA�CTEMOCS A B C 0 E F 0 K L M N P WE WETWO M w x M 246NB724 0 I 0 0 0 31 3116• 39 3//• 3 311• 3l/' 6 9116' 24 11116' 9 118' 2 13/16' 1/2' 16 1/4' 15 311• 16 311• 223 211 32 5/16' I 35 112•S 46 118- 2q 8736 0 I 0 0 0 31 3/16' 39 311' 3 718' 718' 1 6 9116' 124 11/16• 9 118• t 15116• 3/8• 15 I//• 16 Ill• I8• 274 309 32 5116. 1 35 Ilt• L 46 I18' aANBl4d 0 I 0 D 0 35' /0 5/8' 3 718• 2/8' 6 9116' 26 1116' 9 118' 2 15/16' 518' 17 314' 16 1/2' IB ]l1' 298 341 36 118. 139 Ill' 1 46 Il8' 24MBTW 0 I 0 0 0 35• 47 1116' 3 7/8' 718' 6 9116' t6 1116' 9 I!e' t IS/I6' S/8' 11 I//' 16 11/' 21' 351 391 36 IIB' 1 39 I//• 119 9116' l YES O 0= X0 A so. ALR DISCHARGE \ AR M q IN DISCHARGE 1111111111111111111111111 lull B AIR INS FIELD FOIER SUPPLY CONN. N F 01 I!8' HOLE N FAIR IN FIELD CONTROL SUPPLY CONN. 0718' HOLE 8, MEMO I LIQUID LINES C NN. P 3. L E L I I I I C 3 vz• 1 IIB' Sll6' K ALR IN OOVAPOR LINE CONN. 0318. 7IEDOWN KNOCNOU7 111 PLACES NWMIAI UNR SIZE NDUNMPAD DINEN90NS 24,36 31 Ill• 131 Ill' 4&G0 ]5' 135' DIMENSIONS - SI IA1R SEES g1�CTFAISCAn� A B C D E F 0 K L M N P 777 GKr DI@E] c9 x N x LN 24Mv 0 1 0 0 0 192.5 1009.4 95.6 19.1 166.1 626.3 231.3 70.9 12.8 412.8 400.1 425.5 124 821.2 1 901.2 X 1172.2 zapvDTOe 0 I 0 0 0 192.5 7009.1. 91.9 22.2 166.1 626.3 231.3 71.5 16.3 381.4 412.8 457.2Ido 821.2 T.901.t i 1112.2 zapueTaU 0 I 0 0 0 889:0 1031.5 97.9 22.2 166,1 722.8 231.3 7/.5 16.3 450.9 419.1 116.] 155 911,1 1 997.7 1 1172.2 zaaveTso 0 i 0 000 689.0 1205,3 97.9 22.2 166.1 722.8 23113 71.5 16.3 3 .2 125;5 533.1 180 911.1 x 991.7 S 1315.1 sP Ip 1 = YES 0 = NO N A SO. AIR DISCHARGE M AIR1 IN DISCHARGE \ / 0 W AIR INS B FIELD CONTROL F-AIR IN SUPPLY CONN. 022.23 HOLE N FIELD PONES SUP8.58 HOLEPLT COX&. ♦82 El mHE HOW LIQUID LINE0C6NN. P 16.2 L E 11.6 C 88.9 8.0 KAIR IN 09.53 TIEDDNN XNOCXOUIS 121 PLACES 0D 9APOR LINE CONN. MBINUh1 UN7' SDE Np1AYIQJG PAD Da1EMONS z+,36 800.1 x 800.1 +e.60 1869.0 1889.0 CLEARANCES Clearances (various examples) Wall F Wall, 6" 152.4 mm) 24" Service (6 9'.6) (304.'8) Service 12" 6„ (304.8) 152.4) d 12" (304.8) 12" (304.8) Wall 24" 24" 24„ (609.6) (609.6) (609.6) Service Service Service 24" 24" 24" (609.6) (609.6) (609.6) Note: Numbers in () = mm IMPORTANT: When installing multiple units in an alcove,roof well,or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. A07833 l>CIIpD�QI Page No. 1 a/,.Q Pages •i l YI7"IYNLJ _ ii KOLB MECHANICAL CORP. Heating and Air Conditioning 11500 ScundAve,P.O.Box 106 Matlituck.NY 11952 (631)2913-5527/Fax(631)298-5534 PROPOSAL SUa.oT1ED TO PH N=om Thas !DATE Ball STREct J09 NAt:'c _ I 2014 P.O. Box 1708 1890 Arshamomaqueveu Ane CRY.STATE Ah'D ZP J09 LOCATION Southold, NY 11971 Southold N.Y. 11971 EhAILADeR=SS CELLPHONE TBHB anonton.lt= net Revision from 7/16/4 JZ/St lYe hemb7 submit spev`catias and esfmatc^.far. - Fumish and install new central air conditioning system to consist of the following: II (1) Carrier, model #F1ACNB006, 5 ton air handler to be installed at residence attic above Garage, suspended from roof rafters by means of threaded rod and kindorif with secondary i 1 drain pan and moisture sensor. I (1) Carrier, model #24ANB760C Coastal, 5 ton outdoor condensing unit to be located at residence exterior on west side of the house. Unit is to be set on a pre-cast condensing slab. Ductwork: Trunk duct system shall be fabricated from 26 gauge galvanized steel. Supply I, and return air duct shall be wrapped with 11/2" foil faced, scrim covering. Both supply and return duct plenums shall be internally lined with acoustical liner. Branch duct shall be premium series foil faced, class 1 Flexible duct and 26 gauge insulated galvanized steel pipe. All branch line take-offs shall include individual balancing dampers. Supply outlets shall be to each room as required. Minimum of one centrally located return air grille per system. Accessible manual balancing dampers to be installed for each supply outlet at main duct connection. Mechanical equipment, ducting, piping location & design by Kolb Mechanical Corp. I Includes: I (1) Multi stage thermostat. (1) SpaceGard 2210 Media Filter. ' Control wiring connections. Hart&Cooley grilles. Low voltage wiring connections. ArmaFlex insulated type"L"nitrogenized refrigeration piping. Condensate drain connections. Secondary pan and switch. i i All necessary materials, labor, installation and start-up. *Upon aweptanw.p!easa date,syn by the-x'and ra um Ye'01N wpy¢4th your deposit KOLB MECHANICAL HEATING&AIR CONDITIONING I In the even this account is hm;,m deo to counsel for wileC.bn the Purchaser shall be Labe for all reasonable fees of Kolb MachaNpl Corp.. It is the responsibility of me Homeormer to have qualified Sennet,Mechanics maintain heating and air conditioning oqu'ryment as resulted by man- ! urecmrer in order to preserve i:aman:ies. IAll urtapmenl shall remain pmpedy of Kolb rlerhanfcal CC,... ;it fully Paid All past due aocctous shall ba charged interest of 1.590 per-:cath. I1 Ali payments Dui Upon Rso-, i �t;1LI1jIUIIC he:aty to ltunill matenal end lobar-prp:_�uta�maw=:rth aaet4 spc,::;.calins,for the sum o;: I Base Total I Opticns Total PayTnenl to be made as folloy:s: Grand Total 'T�r;51Gy..>t2] to G.a S.c^S— Al t3 nu,[ a t a hg= Authcaed oto z"su a-�c lrec-_-it*.� Mr +z- ams -•y+ -9 to £igt lune Or—to /:—..tea-ic- r- ., a•. O :.:nee._:,c..c: ,t.ra^�s NCL Ties rxs=may be G+r •cntrs..-c. wiNdm::n tr/us it not se;hni-.,%Hn is days Z1fttIlWRIP, DITtDi10DRI The aha,.pelor,rec'.a5cns and Mn.uon5 are sat:slaclary and are hartry accepted. YoU am culhanzed to II dothovrorkassPeCified.Palm?m:tv]ItomadoasoWredayv,tt. Prnl Noma I I Date of Acceplance — X Signature