Loading...
HomeMy WebLinkAbout46820-Z SOFF04z' Town of Southold �oS o�y 11/28/2021 P.O.Box 1179 53095 Main Rd Southold,New York 11971 Alp CERTIFICATE OF OCCUPANCY No: 42571 Date: 11/28/2021 THIS CERTIFIES that the building GENERATOR Location of Property: 1360 S Harbor Rd, Southold SCTM#: 473889 See/Block/Lot: 75.-7-1.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/9/2021 pursuant to which Building Permit No. 46820 dated 9/14/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. (Maintain shrubs for proper clearances) The certificate is issued to Kingston,Brian of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46820 10/28/2021 PLUMBERS CERTIFICATION DATED u rize 0guature �SUFrotKc TOWN OF SOUTHOLD moo BUILDING DEPARTMENT TOWN CLERK'S OFFICE • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46820 Date: 9/14/2021 Permission is hereby granted to: Kingston, Brian 54 Warren St#2 New York, NY 10007 To: Install generator to existing single family dwelling as applied for. At premises located at: 1360 S Harbor Rd, Southold SCTM #473889 Sec/Block/Lot# 75.-7-1.2 Pursuant to application dated 9/9/2021 and approved by the Building Inspector. To expire on 3/16/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-ADDITION TO DWELLING $50.00 Total: $235.00 Building Inspector pF SOUTyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G, roger.richertCc)-town.southold.nv.us Southold,NY 11971-0959 o�ycOw 0 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Brian Kingston Address: 1360 South Harbor Rd City: southold St: New York Zip: 11971 Building Permit#: 46820 Section: 75 Block: 7 Lot: 1.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Peconic Power Systems License No: ME-45056 SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical OutdoorX 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 22 KW stand by generator with 200a transfer switch,electric meter placard Notes: Inspector Signature: Date: October 28 2021 81-Cert Electrical Compliance Fonn.xls �'6 8���aoEsOUryO4, #© TOWN OF SOUTHOLD BUILDING DEPT. °`�rourm 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ]- ROUGH PLBG. [ ] FOUNDATION 2ND [' NSULATIOWCAULKING [ ] FRAMING /STRAPPING [XFINAL VZV&XfW [` ] FIREPLACE & CHIMNEY [ ]' FIRE SAFETY INSPECTION -[ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REM RKS: ( ; in, v r DATE �� I b 1�Z'� INSPECTOR FIELD:INSPECTION REPORT. 'AATE COivIlviRNTS FOUN,),xnoN(IST) 7777 Q � - -- -� y FO.iATION(2ND) t. i. Q u� RQUGH FRAl TING:& y PuNlsnvc; r i: a INSUL (TION.PER N.Y. y STATENERGY CODE litp I lot FINAL'. ' 4, . _ ADI51TIdNr�C(1NIIVlEI`Y�'�;: ; ,. lo-a86 2 r .r I o \Vcj-a z l.• w °z =o .rm+ as� TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtowmy.go Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector: SEP — 9 2021 Applications and forms must be filled out in their entirety.Incomplete (\G . applications will not be accepted. Where the Applicant is not the owner,an gIJII DITONN OF G DEPTDEPTLD Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S) OF PROPERTY: Name: SCTM#1000- 7 5 -7_ j•x2- Project Address: /3 GO Soh 14",q, Roll Som Aoldi ll99/ Phone#: �g6— X95-oZ/6ff Email: 6�ia,/f. Sfa��i6roo/r� /�Co�. Mailing Address: 1 360 51�A Ne,r60� /lol/ CONTACT PERSON: Name: Joe. uA•Im� Mailing Address: 319 Cn�nMe.c. .Rd 4ox Phone#: Email: DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: 3/S Co^n�nercc Rd C� Ja ,,. /VYll935 RO0°X Sly C-,-tCAycrf-, Phone#:63/-3gj-W0 Email: P eC4nic(.La^'t�5 5® nq;�.CD� DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other 22/rc/ G-enen2c. lrrnc_in �or $ 13i000,o0 Will the lot be re-graded? ❑Yes ZNO Will excess fill be removed from premises? ❑Yes B No 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes []No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit.pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and In building(s)for necessary Inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): bA*uthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) SS: COUNTY OF S�P-Fa l hf ) Roy Sart ,1i;c--l. being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)heisthe Con4rb4912/ (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that,the work will be performed in the manner set forth in the application file therewith. Swornpefore me this 2A day of 20� A�g Notary Public PROPERTY OWNER AUTHORIZATION 1y, I1 (Where the applicant is not the owner) I, yXiaY\ 1y'ar' 'D�l residing at � %o S• �daf 60C do hereby authorize" S&.;P.Vi�,�+ to apply on my 4Fitai e Town of Southold Building Department for approval as described herein. 974 Z£� 91 Owne Signature MftE nomu Date 77 NGTAffPAM Mn OF NBYIY= n PrI&A IuS/,or) Print Owner ame ����� 2 =o�OgUFFO(,r�oG` BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 C* • Southold, New York 11971-0959 'yfj o� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerrCcDsoutholdtownny.Qov - seand(&southoldtownnv.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: q ap- ) Company Name: ; o , Name: Roy Sf n License No.: MF_-45056 email: Phone No: f- -8soA ©I request an email co of ertificate of Compliance Address.: 31S Go ce /1d CL- �� iig3 JOB SITE INFORMATION (All Information Required) Name: &,-an ktl o„ Address: 360 5,, Eanb, R I/9 Cross Street: Phone No.: GyC- Bldg.Permit#: — email: I an �xa�kF; Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) ltu (yP/Jeio c Ge,eia fz,r Check All That Apply: Is job ready for inspection?: DYES ®NO ❑Rough In [-]Final Do you need a Temp Certificate?: DYES ❑NO Issued On Temp Information: (All information required) Service Size 01 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.)dsx MAIN ROAD 140. DISTRICT: 10,00 SECTION: 75 PLUCK: LOT:S;: T.i I LAND N/F Or ( ANN PFr.RA(ISJAS TRUST w f N 80°21'10"E 400.00' nt /I °'w wR. d.F "9'A. !k"N. lENfA r +a.r •kk i, �. 0D a rtn<xr Xr CNragcw FENeE aAn "2� l q `�fi+F+ �/ "� O c��r r GARDEN IX x P"4CPM ALM x 16D o 1 Nis O. `. t .te FF�tyl t4l x I+ FRAM I�Irf' !LJ j �II71AV "Ict) X A Saps sc ROCA 3 s w I f ?•, CAM 4 uNAYR J(fNEYar —��' f 'i $ L v' r Das N.xr. e•Padr,waE racer D.�' '- t x 1.84 ACRES S80021'10" W as nntE AREA:7999[:.bS Sy. fACRES400.00' :MNC•rF ZiD ALYECAT*W 1x.AtOlia! M AM>Stf+iFY R A MTn AiH IT 4:r•RIW i?L'0 rW nE NCW WVM TATE Ei4N ARCIN LAW '%rAF5 LV NS S(A?Vn LAND FIS F OF NfAM NO) LANDS. THE LA �b'IEH,q'S EA9ln_'SEO SEA1. ALL W7 I*:'.W:A1CMP rJ FE A YAL:T MIT LDFY. QiAA1N1EES MLki tiCD eM:W;WALL FUN O•e.f m P,4 NAI'M AW WQV 1lf. Ary1RIEY 15 PRWAREP ANL�W MS u-Ai?a W RILE CLd PANT, OOt£ANAIENrA! AG CY Ak't NO CS^;UPON 1350 SDUTN 'ISrL NE'Rrrya A.w) QRff ,LN_ES C7 INC L&M aIS.'MHN. C Amlli):Ar ARE'+1'E'1 MANVf AdLC ' rw. 4'TSE/S rR rA.."AnS IWAN RERc�W Mew IIE PRlR.I:'LM'E.f TO INC Sr rHC S WC fCR A SK1 IC J WO:T ANO rJS MEHEr0.4E INET ARE H4W90R FQ4D LLC Mr LMCA r:+Ikvpwfwt NF M.rrkrY U ,v lr. r0 W" wERE:w%I eF sfatY:. AEAAFOWC SrRUOPU I,AND)UC7t.wFRD12:vENIS. EASENENiS AAO,.i?R r.U✓7F,At'C STN Itws REwawp CR UNFF"ccwm.ARE M.'T G'i49ANKi1•;lens PNIS•CKLr ENDENr s NE PFE ws Ar Ti1C 1NE a SURI£Y ' re-:GE5i:M1uL 'f QKRrr CERTIFIED 70.BRIAN RINGSTDN• NnP rs': i FIDEUT NATIONAL TITLE INSURANCE `ERYICES LLC.' �uu _ TCwi v":^Cfl.l 111U D :'J1f F'(4J IXAINT;, HLW YCRf EBNNEEH Y IIOYC11V1(_I yV S.yRiM NG• PLLC IW W41ER SUMP, MELLS DRYXUS AND C'ESSVM ProfeLNdonal land Sll xying and D"dign LOGARONS -940OW ARE FRO1f FIELD OBS'ERVATTONS P.O. Box 153 Aqu"bogue, New York 11931 AMO OR DATA OBTAWED FRW OTHERS rx., d 11:'i- :;.. e+•ML'1":::;:p• DAM:7-17--20 .__. .— PIIDNx (dd)12YM-LSBN F"M)q :Rd-t5d" N.t. L:g N0. u.4'F?S AC V CERTIFICATE OF LIABILITY INSURANCE DATE(MM Do mY7 L� 06/21/2021 THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not Confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CONTACT NAME: Josh Mitchell Freedom Coverage Corp PxoNE (631)709-2777 Fc Ne: 80 Orville Dr Suite 100 nut Hess, Josh@FreedomCoverageNY.com Bohemia, NY 11716 INSURERS AFFORDING COVERAGE NAICe INSURERA: Midvale Indernity Company 27138 INSURED INSURERS: Employers Insurance 11512 Peconic Power Systems LLC INSURERC: 315 Commerce Rd INSURERD: Cutchogue, NY 11935 INSURERS: INSURER F: COVERAGES CERTIFICATE NUMBER: 00000166.77552 REVISION NUMBER: 4 THIS IS TO CERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FORTHE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILSR TYPE OF INSURANCE ADSL SUER POLICY NUMBER MM/DDEOT MOIOCGYEXP LIMITS A X COMMERCIAL GENERAL LIABILITY GLP1092481 0512812021 05/28/2022 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE FXIOCCUR PREMISES Ea occrnen 8 1 OO OOO MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMB APPLIES PER: GENERAL AGGREGATE $ 1.000,000 X JEST F1 LOC PRODUCTS-COMP/OP AGO $ 2,000,000 POLICY❑ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT nt $ Eaa We ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY( eramitlant AUTOS ONLY AUTOS P ) $ HIREDNON-OWNED PROPERTYDAMAGE $ AUTOS ONLY AUTOS ONLY More ant) UMBRELLA LIAS OCCUR WACCIDENT RENCE $ EXCESS LIAR CLAIMS-MADE $ DEC) RETENTION$ $ B AND EMPLOYERS'COMPENSATION LIABRRY EIG4706645 0210312021 0210312022 X ERH ANY PROPRIETOR/PARTNER/EXECUTIVE YIN IDENT $ 1,000000 OFFICERIMEMBER EXCLUDED? NIA (Mandatory in KH) EA EMPLOYE $ 1,000,000 DESCRIPTION OF OPERATIONS beow describe order POLICY LIMIT $ 1,000,000 DESCRIPTIONOFOPERATIONSILOCATIONS/VEHICLES(ACORD 10t.AddlHonal Remarks Schedule,maybe attached Senors space is required) As pertains to insureds operations CERTIFICATE HOLDER CANCELLATION Town of SDuthhold- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Building Department THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN 9 P ACCORDANCE WITH THE POLICY PROVISIONS. Town Hall Annex 54375 Main Road P.O. Box 1179 AUTHORIZED REPRESENTATME Southold, NY 11971 TCG JCM ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Printed by JCM on June 21,2021 at 09:01AM OCCUPANCY OR APPROVED AS NOTED USE IS UNLAWFUL DATE: B.P. (v�s2O WITHOUT HOUT CERTIFISCFzl ' ff11 FEE:46.93516 BY: Or OCC UIr"41Fy v+r* 0.1 ; NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FCR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE COMPLY WITH ALL CODES OF REQUIREMENTS OF THE CODES OF NEW NEW YORK STATE & TOWN CODES YORK STATE. NOT RESPONSIBLE FOR AS REQUIRED AND CONDITIONS OF DESIGN OR CONSTRUCTION ERRORS. SOUTHOLD TOWN ZBA - SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y.S.DEC sBCfPnuRiSPM-M REQeMm GENERAC® 20.MV24 W GUARDIAN° SERIES _ Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating INCLUDES: G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True PowerTM Electrical Technology 6007042-2,G007043-2,GO07042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz GO07209-0,G007210-1 (Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution'" controller (Engl ish/Spanish/French/Poduguese) • 200 amp service rated transfer switch available • Electronic governor o ` • Standard Wi-Fi®connectivity I • System status&maintenance interval LED indicators =,�I • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENERAC -- -- • 5Year limited warranty • Listed and labeled for installation as close as 18 in(457 mm)to a structure.' 'Must be locatedaway from doors,windows,and fresh alrintakes and in Sm accordance with local codes. or c(�Dus Q 1' - CNote:CETL or CUL certification nonly CappplJies tounbundled unitsanduni s packa5ged With limited circuit switches.Units pacl¢ged with the Smad Switch are L4L or t1L certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success In providing the most reliable generators possible. Geneiac's G- state-of-the-art power maximizing regulation system Is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times In high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER-ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides pads and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Lang life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fl allows users to monitor generator status from any- where in the world using a smadphone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link,users are taken care of before the next power outage. GENERAC PROMISE GENERAC® 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,lightweight unitthat operates 25%more efficientlythan a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL2200listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution— Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verity the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verities engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent all seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. r GElIERAC® 20/22/24 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI 721.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current slate of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC' 20/22/24 kW Specifications Generator Model G007098-1 G007042-2 G007038-3 G007042.3 G007209-0 G007039-1 6007043-2 G007039-3 G007043-3 G007210-1 (20 kW) (22 1W) (20 WO (22 IW) (24 kW) 'Baled maximum continuous power capacity(LP) - _20,000 Wafts' 22,808 Wafts* _ 20.00DWafts' 22,00OWatls' - -24,OBOWatls' Hated maximum continuous power capacity(NG) 18,000 Wafts' 19,500 Wafts' 18,000 Wells- 19,500 Watts' 21,000 Watts• Bated voltage 240 - - Bated maximum continuous load current-240 vo1a(LP/NG) 83.3/75.0 91.1/81.3 _ 83.3/75.0 91.7781.3 _ 100/87.5_ _ ' Total Harmonic Distortion- Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp ;_Phase ._ _._ .. _ - _ I _ .. _ - Numberofrotorpoles 2 'Hated AC frequency _ _ _ 60 Hi Powerfactor 1.0 Battery requirement(not inc_luded) _ _ 12 Volts,Group 26R 540 CCA minimum or Group 35_AGM 650 CCA minimum Unit might(Ile/kg) 448/203 4661211 436/198 445/202 455/206 Dimensions(L x W x H)in%cm _ _ _ _48 x 25 x 29/121.9 z 63.5 fr 73.7_ Sound output in dB(A)a123it(7m)with generator operating at normal load•' 67 67 67 67 57 _Sound output in d_B(A)a123 fi(7 m)with generatm io Duret-Test'low_-speed exercise mode`• 55 57 55 57 _ 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders _ _ _ _ 2 Displacement - _ 999 cc - Cylinder block _ _ _ Aluminum w/cast Iran sleeve Valve arrangement _ _ - _ Overhead valve Ygnition system _ _ _ _ _ _ Solid-stafew/magneto Governor system - _ Electronic ,Compressiomra0o _- - - - 9.5:1 starter _ fzwc ,011 capacity Including filter _ Approx.l.9 qt/1.8 L - Operatingrpm - 3,600 I Fuel consumption Natural gas its/hr(m'mr) 12 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Lead 301(8.52) 327(9.26) 281(8.13) 306(8.66) 'Liquid propane IP/hr(gaI/hr)M] 12 Load 87(2.37)[8.99] 92(2.53)[9.57] 96(2.36)(8.95] 92(2.53)[9.57] Full Load 13D(3.56)[13.48] 142(3.90)[14.77] 136(3.74)(14.15] 142(3.90)[14.77] Note:Fuel pipe must he slzed for full load.Hequired fuel pressure to generator fuel Inlet at all load ranges-3.5-7 In water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply fta/hr x 2500(LP)or fl3/hr x 1000(NG).For Megaloule content,multiply ms/hr x 93.15(LP)or ma/hr x 37.26(NG). Controls Two-line plain le#multilingual LCDSimple user interface for ease of operation. _ Ma_d_e bu00ns:AUTO - Automatic start on utility failure.Weekly,Bl-weekly,or Monthly selectable exerciser. MANUAL SW with sailer control,unit stays on.II utility falls,transfer to load lakes place. OFF _ _Stops unit Power Is removed.Control and charger still operate. Readyto Run/Malntenance messages Standard Engine ren hours indication - Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer cniy)_ IUt11.14Voltage Loss4aetum to Utililyad)usable(b(ownout setting) From 140.171 V/190-2.16'_V - Future Set Capable Exerciser/Exercise Set Error warning Standard _ _ BuivAlamVMaintenance logs - 50 events each Englne start sequence Cyclic cranking:16 sec on,7 rest(90 sec maAmum duration). 'Stader lock-ore _ Starter cannot re-engage until 5 sec atter engine hzs_sloppe_d. Smart Battery Charger Standard Charger FaulUMissingAL warning _ _ _ _ Sai0rd _ Low Battery/Baffery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation M6 Over and Under Voltage Piotection _ Standard _ Under-Frequency/Ovedoad/Stepper Over-current Protection Standard Safely Fused/Fuse Problem Prdtection - _ Standard Automatic Low Oil Pressure/High Oil Temperature Shutdowns Sandard �Overcrank/Overspeed(@ 72 HzVrpm Sense Loss Shutdown Standard High Englne Temperature Shutdown Standard Internal Fault6correct Wiiing protection _ Standard _ Common exlemai autt capability Sandard Field upgradablefrmfwaria Standard **Sound levels are taken from the horn of the generator.Sound levels taken from other sides of the generator may be higher depending on installation paremetem Bafing definitions-Standby:Applicable for supplying emergency power for the duration of the Wlity power outage.No miload capability is avallable for this rating.(mI ratings In accordance with BS5514,IS03046 and DIN6271).•Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 0(304.8 net above sea level;and also will decrease approximately 1%for each 10'F(6°C)above 60°F(16°C). GENERAC® 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features G007039-1,6007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. Model 6007043-2,6007043-3(22 kW) __________ __ _ _ • Up to eight additional large(240 VAC)loads can be managed when used In conjunction No:alpoles _13007210-1(24 WW) _ with Smart Management Modules(SMMs). Cu •--rre_...__._ _)_..__._ .. nt ra0ng(amps200 • Electrically operated,mechanically-held contacts for fast,clean connections. wolage ratlny'UA I, _ _ _ '_ __ _-------120/240,10 • Main breakers are rated for 80%continuous load. Utility vol age monitor(fixed)• -Plck-up 80% r • 2-pole,250 VAC comactcTs. -Dropout 65% • Service equipment rated,dual coil design. ;AeturntoUtiliry __ _ v i._ , _ __ _ ApPoxi3see _ EfL or UL listed Standard • Rated for both aluminum and copper conductors. Enc _ . __.__NEM_N_UL__.3A__ iowre type___ _ _ • Main contacts are Silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. ;Wgrange _ _ _ 260MCM-_a6 'Function of Evolution control Dimensions Exercise can be set to wee My,bl-weeldy,or monthly m 200 Amps 120/240,10 Open Transition Service Rated Height Width Depth 111 H2 W1 W2 In 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 w " wire Ranges Conductor Lug Neutral Lug Ground Lug 250MCM-#6 350MCM-#6 1 2/0-#14 oevrx L—va J GENERACO 20/22/24 kW Available Accessories Model# Product Description . _ _ _ - i �G00710!660710-1-d-0 BatteryPad Warmer ;Padrm waer rests under the battery.- Recommended for us. e_itte..mpersN 're regularly falls below 0°F(-18°C)..(Not nee--; !essary for use with AGM-style batteries). i 00071-02-0 [6fl Warmer —;Oil warm erslips directly overtha-oil I Hter.Recommended for use iff temperffiure rug ulady falls below 0*-F-(-1 B°c). —' 10007103-1 Breather Wa mer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy Icing occurs. a ' IG005621-0 Auxiliary Transfer Switch ;The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not Contact KB needed.Not compatible with 50 amp pre-wired switches. 0007027-0-Bisqua !Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured !(Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque iTouch-Up Paint MIf the generator enclosure is scratched or damaged,h is importantto touch up the pa ntto pmfeetfrom hAure corrosion. The touch-up paint kit Includes the necessary� �- ry paintto correctly maintain or touch up a generator enclosure. 10006485-0 !Scheduled Maintenance Ki[lGenerac's scheduled maintenance kit provides all the Items necessary to perform complete routine maintenance on a i I Generac automatic standby generator(o1 not included). I 1GO07005-0 Wi-FI LP Tank Fuel Level The WI-FI enabled LP tankfuel level mor Fh r provides constant monitoring of the connected LP fuel tank Monitoring the; Monhor SLP tanks fuel level is an important step In verifying the generator is ready to ren during an unexpected power failure.Sta- Aus alerts are available through a free application to notify users when the LP tank Is in need of a refill. ;0007000-0(50a-in pj;Bmaii ffaraijementModuIii;Smart Managemint ModLit es(SMM)are-us—ed tooptimlie theperformanceofaSite ndbygenerate r.itmanagas-largealae-1 IGO07006.0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce; ;(100 amp) !the overall size and cost of the system. _---- ss -- - — - - ----- --..—. _ re in _ ) 0007189-0.46-Cf E !Mobile Link®Cellular- The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using 13007170-0-Wi-FU 'Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us-! Ethernet ' lers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, ' I —'users are taken care of before the next power outage. !0007220-0-Bisque ;Base Ku g Kit - ;Base plugs snap Into the liiVngholes on the base of air-cooled home standby generators.This offers a sleek,coniou�l 'appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.K t; 'contains four plugs,sufficient for use on a single air-cooled home standby generator. ._ Dimensions & PCs Model UPC � ;, taa , G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 T2..2mm ae mI G007042-3 696471074208 G007043-2 696471074215 QE G007043-3 696471074215 0 0 0 G007209-0 696471071511 G007210-1 696471084801 1256 NI LEFT 810E VIEW FROM VIEW Dimensionsshorm are appmdmate.See Imt4alial manual for met dimensions.00 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES G E N E RACO Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.cmm ®2021 Generac Power Systems,Inc.AH right reserved.Aespeed"ons are wblectto change w0outnotice.PaMA0000a37814 Rev.D OW10021