Loading...
HomeMy WebLinkAbout46793-Z oo�Og�FfO(q cpGd Town of Southold 11/28/2021 P.O.Box 1179 m. 53095 Main Rd Gyho� �ao3r Southold,New York 11971 f CERTIFICATE OF OCCUPANCY No: 42574 Date: 11/28/2021 THIS CERTIFIES that the building GENERATOR Location of Property: 390 Oak Dr., Southold SCTM#: 473889 See/Block/Lot: 80.-2-14.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/30/2021 pursuant to which Building Permit No. 46793 dated 9/8/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Gallagher, Christopher&Catherine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46793 10/28/2021 PLUMBERS CERTIFICATION DATED Aut zed D ature �o�SOFrniK�G TOWN OF SOUTHOLD Gyp BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . g SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46793 Date: 9/8/2021 Permission is hereby granted to: Gallagher, Christopher PO BOX 287 Southold, NY 11971 To: install generator as applied for. At premises located at: 390 Oak Dr., Southold SCTM #473889 Sec/Block/Lot# 80.-2-14.1 Pursuant to application dated 8/30/2021 and approved by the Building Inspector. To expire on 3/10/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $235.00 it ' Ctor ho��pF SOUTyOIo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.o.Box 1179 c, o roger.richert()town.southold.nv.us Southold,NY 11971-0959 .� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Christopher Gallagher Address: 390 oak Dr City: Southold St: New York Zip: 11971 Building Permit#: 46793 Section: 80 Block: 2 Lot: 14.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Peconic Power Systems License No: ME-45056 SITE DETAILS Office Use Only Residential X IndoorX Basement X Service Only Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fbdures Time Clocks Disconnect I I Switches Twist Lock Exit Fixtures TVSS Other Equipment: 18 KW stand by generator with 200a transfer switch, electric meter placard Notes: Inspector Signature: Date: October 28 2021 81-Cert Electrical Compliance Form.xls f TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ '-KFINAL7,*ad [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY;INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT•PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE �� ����Z-� INSPECTOR FIELD.INSP CTION REPORT. DATE S r, FOUNLNATLON;'(1ST) • Y Y� • . . FO ATION(2NA) j ROUGH FRAl?IING:& off , PLUMBING. ' . l� j INSULATION.PER N.Y. H STATE'PNI;RGY 601A i j FINAL tie „ o. a a (e l'G c .i Z �m 1 . �e Nz �ao� tcO4s '' TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 a� Telephone(631) 765-1802 Fax (631) 765-9502 hqs://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PE MIT p [ECEDIVIE For Office Use Only D 2 AUG 302021 PERMIT NO. J Building Inspector: inn Applications and forms must be filled out in their entirety.Incomplete BUILDING DEPT: applications will not be accepted. Where the Applicant is not the owner,an TOWN OF SOUTHOLD Owner's Authorization form(Page 2)shall be completed. Date: IA'lgll OWNER(S)OF PROPERTY: Name: G hers uh SCTM—# 1000- Project 1000-Project Address: 3`IO Oak (2.J acv /(q7 Phone#: 63 71 5- 3$N Email: 6Z A" Cy e2r%l,At- n Mailing Address: _39L Dalt I "4t o A7 CONTACT PERSON: Name: nn �.e✓tdti Mailing Address: P O 0 x 5-1 �2, 3 r- Phone#: 5J(o - I R - -7 1 q ) Email: �� S DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: re�n � Mailing Address: (301 S( a- Cu rr e '//?,35'- Phone#: C31 — 7.3`'(- S-0 ,94 Email: 5 DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: C$6ther /$/mow 64Ae Cf#.c. $ //X Will the lot be re-graded? ❑Yes 260 Will excess fill be removed from premises? Dyes Flo i o��SQFF01K�o BUILDING DEPARTMENT- Electrical Inspector �� Gy TOWN OF SOUTHOLD o Town Hall Annex- 54375 Main Road - PO Box 1179 o Southold, New York 11971-0959 'y O� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cilsoutholdtownnv.aov — seandna outholdtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 9/3d/a I Company Name: A- n , o s lcMS Name: Sl�v.�Ldt- License No.: M E— yso f6 email: �� ,` �w �5 s © Phone No: 5'/6-g r --7(q 1 [Kirrequest an email copy of Certificate of Compliance Address.: PQ x 5-12 ,� ..e, ti l 3S JOB SITE INFORMATION (Al Information Required) Name: C' 11 Address: 3qD w!- U Cross Street: Phone No.: 6.31 - 765— - 39q3 Bldg.Permit#: 7 F3 email: G nc1— Tax Map District: 1000 Section: Block: Lot: 9 BRIEF DESCRIPTION OF WORK (Please Print Clearly) 19kiiv Caen-erw� 6-ex. "to,-- 9-c9oA- Check All That Apply: Is job ready for inspection?: DYES L2-140 ❑Rough In ❑Final Do you need a Temp Certificate?: DYES E]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service F1Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame [—]Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION ��L •/,J � ��� Electrical Inspection Form 2020.Asx P'1 SCOHS v RIO - 94 - 0013 !t , I e ern i Z ,`a 104 1, 4* W NI Pd Q e 0TH w « oo, f ak°lac n AREA = 19,842 sq. ftto tie/u1e nc nom D• end W1 G ANAVA ONS ARE A TLAL NCm Lamy TO AN A55I,ME0 DA TIAL CLAY 2B eaorx ANf ALTERATKW OR ADDfI1CW TO THIP S1.RVEY 1S A VIOLATWMI ILAr OF SECTION 7P09 OF THE NEW YORK STATE EDUCATION LAI. 33' EXCEPT AS PER SECTION TPO9 - SLOWNION E ALL CERTFlG TAWS IETEQV AHE VALO FOR TMS IMP AND COPES THEREOF OILY IFBMW COARSE SAO IMP OR COPIES BEAR THE BNESSED SEAL OF THE SLFVEYOR �bg'.a, Ano VERY WHOSE SMATLOW APPEARS HFJEOFL f <CAR 39 ADWT144ALLY TO CNP1.Y WITH SAO LAW T!E TEAM 'ALTERED BY' a,noa "r BE USED BY ANY Aro ALL SURVEYORS UT1.90OG A COPY 131' OF ANOMER SURVEYOR'S MAP. TEAMS SIA71 AS W.SPECTED"AND 'TER 'n 'BROUWT-TO-DATE'ARE NOT N COMPLIANCE WrH THE LAW. eaorn ooAaac 'ea Axe140e! o/ rat aid erasaoWs Nom bracer aro Iron nese Aryo VEflr a6,arrabw mJ or kaaa dale le Iran, 010W& a,Lace 17 THE WATER SLPPLY AND SEWAGE DISPOSAL COAPLY WITH THE STANDARDS L wcolA4ElElrs OF RE Sfr'FOLK CoK.NTY DEPART&SYT OF HEALTH. SURVEY OF PROPERTY CERrFIFO 'To, AT SOUTHOLD CWSTOPHER GALLAGHER TOWN OF SOUTHOLD CATHERINE GALL AGf ER MS�ANC£COMPANY TITLE SUFFOLK COUNTY, N Y. HSBC MORTGAGE CORPORATION, USA 1000 - 80 - 02 - P/0 14 SCALE& r' = 30' JAM 29, 1893 MAR. 22, 1984 1 foundation 1 FEB. 4, 2000 / final 1 MAR. 15, 2000 f eWrMeaRon 1 JF NEW Mlr!`O9'f •:'q� E 314/94 CER TFICA TION I.Y ". UC. NO. 496-8 "/PI CER TFICA TOV el„aa IaI�.Ic P.C. LOT NUfENS REFER TO BLOCK ' D 16'7 X 1631)765-1797 MAP OF REYOW SHORES, W— , BAY4W P. O. L L N.Y. ' FLED ALLY 2, 1931 W THE OFFICE 1430 TRA R STREET OF TLE SUFFOLK COUNTY CLERK AS YAP NO. 631 `OUTHOLD, N.Y. 11971 s lu l a Arno, 88 - 315 ACS CERTIFICATE CERTIFICATE OF LIABILITY INSURANCE DATE(MM DDYYV ) L� 1 06/21/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CONTANAME, Josh Mitchell Freedom Coverage Corp PNONE Emr, 631 7o9-2777 FAu Ne: 60 Orville Dr Suite 100 AQ VSs. Josh FreedomCovera eNY.com Bohemia, NY 11716 INSURER AFFORDP40 COVERAGE MAIC0 INSURERA: Midvale Indemily Company 27138 INSURED INSURER B: Employers Insurance 11512 Peconic Power Systems LLC INSURERC: 315 Commerce Rd INSURER D: Cutchogue, NY 11935 INSURERS: INSURER F: COVERAGES CERTIFICATE NUMBER: 00000166-77552 REVISION NUMBER: 4 THIS IS TO CERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FORTHE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRsunTYPEOFINSURANCE IN Wve mu"NIMe R PODGY EFF PODGY E%P LIMITS A X cOMMERCIALGENERAL LIABILITY GLP1092481 05/2812021 051291022 EACH OCCURRENCE $ 1000000 DAMAGE TO RENTED CLAIMS-MADE FRI OCCUR PREMISES1Eao=aenwI $ 100,000 MEOEXP Anyonapemon) $ 5,000 PERSONAL&ADV INJURY $ 1.000.000 GENL AGGREGATE LMR APPLIES PER: GENERAL AGGREGATE $ 1,000,000 X O. POLICY El JECTT FILOC PRODUCTS-COMP/OP AGO $ 2,000,000 OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Eaecadent ANY AUTO BODILY INJURY(PerPerson) $ OWNED SCHEDULED BODILY INJURY(PereccWeM) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per 1 $ UMBRftLLAL1l1B OCCUR EACH OCCURRENCE $ EXCESS LUIB CUVMS-MADE AGGREGATE $ DEO I I RETENTION f B WORKERS COMPENSATION EIG4706646 02/0312021 02/0312022 srArurE X F EOTH- ANDEMPLOYERS'LIABVJTY ANY PROPMETORIPARTNERIE) CUTNE YIN EL EACH ACCIDENT $ 1,000000 OFFICERMEMSER EXCLUDED? NIA (Mandatary In NH) EL DISEASE-EA EMPLOYE $ 1,000,000 Xyes,desabe Under DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES DICORD TeI,Additlonel Remarks Sebedla,me)rfro eUSMwd 1/mom speaoNmgNm,Q As pertains to Insureds operations CERTIFICATE HOLDER CANCELLATION Town of SOuthhold• SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. Town Hall Annex 54375 Main Road P.O.Box 1179 AUTHORIZED REPRESENTATIVE Southold, NY 11971 JCM ©1988.2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD Printed by JCM on June 21,2021 at 09:01AM C2, APPR VED AS NOTED DATE: B.P.H FEE: - BV: NOTIFY,BUILDING DFP4RTMENT AT 765.1602 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH -.FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONS'P j ,i ION MUST BE COMPLETE F0z ^0. ALL CONSTRUCTI N i .All MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF �G6?NOkFrF94"fN�BA� 49 TOWWWAIINUOARD SGR4effTO tiNiMTEES N4.9. C— OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA- OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED GENERAC® 10/141 kUV GUARDIAN° SERIES _ Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating G007171-0,G007172-0(Aluminum-Bisque)—10 kW 60 Hz • True Power" Electrical Technology G007223-0,G007224-0,G007225-0(Aluminum-Bisque)—14 kW 60 Hz • Two-line multilingual digital LCD Evolution*" controller G007226-0,0007228-0(Aluminum-Bisque)—18 kW 60 Hz (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch • Electronic governor • Standard Wi-Fig connectivity l' _ • System status&maintenance interval LED indicators 1 �) • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation GENERACca i r-� • 5 Year limited warranty � • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a G's st acture.* C@us*Must be located away from doors,windows,and/rash air or C �L us intakes and in accordance with local codes. LISTED https:#assets.swii.orgllibrarylDirectoiyOfListedProductsl Note:CEiL or CUL certification only applies to unbundled units and units packaged with limited Constructionlndustry(973—DoC-204-13204-Ot-01—Re v9.pdf circuit switches.Units packaged with the Smart Switch are ETL or UL certified In the USA only. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and the most.The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended run limes in high temperatures and extreme operating conditions. surge loads to the engine.Digital voltage regulation al it1%. O TRUE POWER—ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides pans and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1.22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with Its own transfer systems and controls for total system compatibility. O MOBILE LINK®WI-FI CONNECTIVITY: FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere In the world using a smadphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link;users are taken care of before the next power outage. PROMISE �' 8Q _ GENERAC® 10/14/18 kW Features and Benefits Engine • GeneracG-Force design Maximizes engine"breathing"for increased fuel all iciency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage tocol%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution" Controls • AUTO/MANUAL/OFF illuminated buttons Select the operating mode and provide easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load.Setpoint approximately 5 seconds. • Engine cool-down Allows engine to coal prior to shutdown.Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation,providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Litt-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. CENERAC® 10/14/18 kW Features and Benefits Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 10/14/18 kW Specifications Generator Model 0007171-0,0007172-0 0007223-0,G007224.0, G007226.0,G007228.0 __ (10 km) G007225.0(14 kW) (18 k 8etedmaximumwhii6uopspgwer`capacity(lP) ` _ " _ - _ _ - ` - _10,000Wags` 14,000 Walls' _ 18,000Walls' _ Rated maximumconlinuous power capacity(NG) 9,000Watts' 14,000Wafts' 17,060 Wafts' Rated voltage _. _. ... _ .. __ _. _ .. . - _ __ ... - _ - .240 Batedmaximumcontinuous load current-24D volts(LPMG) - 41.7/37.5 58.3/58.3 - 75.0770.8 Total Harmonic Distortion _ _ - _ ` ` ` __ _ _ _ - - __ -Less than 5% _ ` -_ r Main line circuit breaker 45Amp 60Amp 60Amp Phase _ _ _ _ . . . . _ _ _ _. 1.. . ,._._ _ - .-. Numbef of rotor poles - - �- - - -- - ' - - 2 .. - - - RatedACfrequency . .-6011,, _ . .... Power lacier - � - �� �1.0 Battery requirement(not included] - 12 Volts,Group 26R_540 CCA Minimum or Group 35AGM 650 CCA Minimum _ Unit weight(tb/kg) __ _ _ _ - - - _ _- _ 338/153 _ _ 385/175 420/191 Dimenslons(LxWxH)m/.cm - 48x25z29/121.9x63.50_3._7 _ _ Sound output in dB(A)at 23 ft 0 m)with generator operating at normal load** - 61 65 65 Sound autpit in dB(A)at 23 0(7 m)with generator in Quiet-Test'"low-speed exercise mode^ ` 57 55 55 Exercise duration - Smin Engine Engine type __ _ _ __ GE_NE_RAC GForce 400 Series GENERAC G-Force 800 Series _ Number of cylinders ` � - _ � 1 � _- _`-�- 2 Displacement _ �- 460 cc 816ce _Cylinder block _ _ ' _ _ - Aluminum w/cast Iran sleeve _ Valve arrangement _ Overhead valve ,_Litter type _ _ _ _ -_ -- _ - - - _ ` -- Solid ` Hydraulic Ignition system _ __ - _ - Solid-state w/magneto _ Governor system - _ _ _ _ _ - _ _Electronic Compression ratio - 9.5:1 starter' -- - 12 VDc Oil capacity including filler _ - -- - - - - Approx.1.1 qt/1.0 L - -- _ ADproa 2.2 07/2.1 L - - --- .Cperatingipm _. _ _ - 3,600 Fuel consumption '_ -. _ _ _ _ _ _ - ._ -- _ __ _ _ .. _ ._. Natural Gas ft'/m(mrYbr) 1/2 Load 101(2.86) 195(5.52) 169(4.79) Full Load 127(3.60) 256(7.25) 247(6.99) Liquid Propane fis/hr(gal/nr)[Ilnr] 1/2 Load 36(0.97)[3.66] 65(1.81)[6.87] 62(1.70)[6.451 Full Load 54(1.48)[5.621 112(3.07)[11.61] 110(3.02)[11.44] Note:Fuel plpe must be sized forfeit load.Requlred fuel pressure to Aenereler fuel inlet at all load ranges-3.5-7.016 water column(0.87-1.74 kPa)for NG,-1G-121dwater column(2.49-2.99 kPa)for LP .gas.For BTU content,multiply 0s/hr,2,560(LP)or itaPor x 1,0001NG).For Megaieule content mui0ply maPor z 93.15(LP)or ma/nr z 37.261NG). Controls _ _ Two-line plain text multilingual LCD` ` -- -- _ - - "- Simple user Interface for ease of operation. _ Mode buttons:AUTO _ _ _ _ _ Automatic start an utility failure.Weekly,Bi-Weekly,orMonthly selectable exerciser. - MANUAL _ _. __ ` _ Start with slarler control,unit stays on_.If utility fails,transfer to load takes place. OFF _ _ _ _ _ _ _ _Stops unit.Power is removed Control and charger still operate. 'Ready to RuNMaintenance messages ` Standard Engine run hours indication _ _ _ Standard Programmable start delaybelween 2-1500 seconds - ` _ Standard(programmable by dealer only) Utility voltage loss/Return to utility adjustable(brownout setting) _ _ _ _ _ _ _ From 140-171 V/190-216V Future set capable exerciser/Exercise set error warning._ _ _ _ _ _ _ Standard - Run/Atarm/Mandenance logs - - - - 50 events each .Engine start sequence _ _ _ __ � Cyulic cranking:16 sec on,7 can rest(90 sec maximum duration). Stader lock-out - Starter cannot re-engage until sec after engine has stopped. _ Smarl Battery Charger - - ` - - _ _ - _Standard Charger Frt/Missing AC Waming Stand a ard Low3aftery/Sahery PrcblereProtecgon and Battery Condition indication _ - _ ` ` _ _ _ Standard Automatic Voltage Regulation with Over and Under Voltage Protection _ Standard ;Under-Frequency/OverloaNStepper Overcurte_nt Protection __ _ _ _� _ _ __ _ Standard Safety Fused(Fuse Problem Protection _ _ Standard _ - - AutomaticLdwOilPressu[e7High Oil Temperature Shutdown _ _ _ -` _- `Standard__- Overcrank/Overspeed(@72 Hz)/rpm Sense_Loss Shutdown _ _ Standard High Engine Temperature Shutdown �__� �_� � " - Standard Internal FaulVlncagect Wiring Protection ___ _ _ _ _ - � _ _ _ _ _ Standard _ _Common External Fault Capability _ _ _` - _ ` " _ Standard Field Upgradable Fimnvare - - l Standard Rating definitions-Oplianal Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability Is avallabie for this rating.(All ratings in accordance with BS5514,1503046,UL2200,and DIN6271). Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Mega]oule content,ambient temperature,attitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 it(304.8 m)above sea level and approximately 1%for each 101F(6°C)above 601F(161C)."Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. GENERAC* 10/14/18 kW Switch Options Limited Circuits Switch Features Model 6007172.0 6007224.0 -. ..------ - -(10 kW) (14 kW) • 16 space,24 circuit.Breakers not included. .No. -"`--"" - ? ofpales_ _ 2 , . . .__.- ---- --' - -- --'- • Electrically operated,mechanically-held contacts for fast,positive connections. Current --ent rating(amps) 100 • Rated for all classes of load,100%equipment rated,both inductive and Voltage seting(-VAC) -120%240,10 esistive. ra _ .__.__. _._ _.___ _ Utility voltage monitor(fixed)' • 2-pole,250 VAC contactors. -Pick-up 80% • 30 millisecond transfer time. -Dropout 65% • Dual coil design. rAetum to utility'. �__ _ Approx.l5sec • Rated for both capper and aluminum conductors. - s-_ _. _ _ _ __._.. Exercises hi-weekly for 5 minutes' Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. — -W - ---- -__ tETLorULListed • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Total circuits available _ _ 24~ -_ .____ _ mounting flexibility. ;Tindembreakercapzbilities 8landems • Multi listed for use with 1 in standard,tandem,GFCI,and AFCI breakers from jan -- -- - line _ -_ _ _ ems Siemens,Murray,Eaton,and Square D for the most flexible and cost effective Circuit breaker protected install. Available RMS Symmetrical 10,000 Fault Current @ 250 Volts Dimensions *Function of Evolution controller Exercise can be set to weekly or monthly Height Width Depth H1 H2 Vit W2 in 26.75 1 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 34.18 17.54 Wire Ranges Conductor Lug Neutral Lug Ground Lug 210-#14 2/0-#14 2/0-#14 Drum l-xx� Service Rated Smart Switch Features Model G007225.0 0007228.0 • Includes Smart AIC Management(SACM)module standard. - -- - - - (14 kw) -— (18 ki) - $ • Intelligently manages up to four air conditioner loads with no additional No.01 poles __ 2 hardware. Current rating(amps) _ _ 200 _ • Up to eight large(240 VAC)loads can be managed with Smart Management Voltage rating(VAC) _ -1-20/2401,10 r Modules(SMMs). UPck voltage monitor(fixed)* 80% • Electrically operated,mechanically-held contacts for fast,clean connections. p • Rated for all classes of load,100%equipment rated,bath inductive and -Dropout 65% resistive. _Returntoutility*, _._-_.__�._ _.. „. 15 sec_ • 2-pale,250 VAC contactors. Exercises bi-weekly for 5 minutes' - _Standard • Service equipment rated,dual coil design. -ETL or ULlisted __ _ _ _ Siaddard'_ • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 311 • Main contacts are silver plated or silver alley to resist welding and sticking. Circuit breaker protected._ 22,000 _ • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor Lug range 250 MGM-#6 mounting flexibility. *Function of Evolution Controller Dimensions Exercise can be set to weekly or monthly m 200 Amps 120/240,1e Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.3 cm 67.94 76.45 26.67 34.3 16.01 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400MCM-#4 350MCM-#6 210-#14 GENERAC® 10/14/18 kW Available Accessories Model# Product Description 1G005819-0 126RWet Cell BatteryjEvery standby generator requires abattery tostart the system.Genera®ffersthe recommended 26R wet cell bat- i i tery for use with all air-cooled standby product(excluding Powerleacf ). 6007101.0 Battery Pad Warmer The pad warmer rests under the battery.Recommended for use if thetemperatture regulady falls below 0°F(-18f i C).(Not necessary for use with AGM-style batteries). r IGdOil-62-0 —_ --- a '011 Wrner a . Oil warmer slips directly over the oil filter.Recommended for use If the temperature regularly falls below 0 F(18°C). I� The breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only In`G007103-1 (Breather Warmer I climates where heavy icing occurs. I — Auxiliary Transfer Switch - The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may I i 6005621.0 Contact Kit not need.Not compatible with 50 amp pre-wired switches. �Die-fasclabasewrap'snapstdgetheraroundthebottoin—of the—nevi iFe6oledgeneratoIs.Thisoffersa-aleek,con=1 {6007027-0-Bisque f Fascia Base Wrap Kit toured appearance as well as offering protection from rodents and Insects by covering the lifting holes located in 1 the base. —I,- --I---.------the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from futtu e; I GO05703.0-Bisque j Touch-Up Paint Kit {corrosion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator en-i ;closure. ' —i _ i G006482-0-10 kW f Scheduled Maintenance Kft I Generac's scheduled maintenance kits provide all the items necessary to performcompieterdotine maintenance IG007216-0-14/18 kW I 'on a Generac automatic standby generator(oil not included). The Wi-R enabled-LP fuetlevel monitor provides constant monftorieg of the connected LP fWtank.Monitoring !6007005.0 iWi-F LP Fuel Level Monitor :the LP tank's fuel level Is an Important step in verifying the generator Is ready to run during an unexpected power, failure.Status alerts are available through a free application to notify users when the LP tank is in need of a refill. jG007000-6(50 amps) i (Smart Management Modules(SMM)are used to optimize the performance of a sstandby ggenerator.R managesi I G007006-0(100 amps) Smart Management Module large electrical loads upon startup and sheds them to aid In recovery when overloaded.In many cases,usingi i SMM's can reduce the overall size and cost of the system. ] iG007169.0(4G LTE) y ® -- The Mobile Link family of CeIIUlarAcceasodes allow users to monitorthe stetus of the generator from anywheTo (6007170-0(Wi•FlrEther- iMobileLink Cellular lin the world,using asmartphone,tablet orPC.Easily access Information such asthe current operating status and I !net) Accessories I maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proac L_____ _-_____._._ _ )five service.With Mobile Link,users are taken care of before the next power outage. I Dimensions & PCs Sane mm ,21 40.ae.o mm (Tri,NI Iin] Model UPC G007171-0 696471074680 G007172-0 696471074673 G007223-0 696471082548 7 2M V.e int G007224-0 696471082555 G007225-0 696471082562 G007226-0 696471082579 0 0 6007228-6 696471082586 e.e mm ,�aTmm p55 NI IaSe int LEFT SIDE NEW FRONT VIEW Dimensions shown are approdmate.See Installation manual for mot dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENE RAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com 02020 Generac Power Systems,Inc.Aliaghtsmservea Allspecfttonsamsubleetochmgewboitnotice.Part No.A0o00973374 Rev.A 10/22/2020