Loading...
HomeMy WebLinkAbout46684-Z ��oSUFFOIX 1pG� _ Town of Southold 11/28/2021 a P.O.Box 1179 y z, 53095 Main Rd �y0� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42568 Date: 11/28/2021 THIS CERTIFIES that the building, SOLAR PANEL Location of Property: 85 Watersedge Way, Southold SCTM#: 473889 Sec/Block/Lot: 88.-5-56 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/3/2021 pursuant to which Building Permit No. 46684 dated 8/12/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Regan,Martin&Eileen of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46684 11/16/2021 PLUMBERS CERTIFICATION DATED t orize ignature -'� TOWN OF SOUTHOLD royaSQFfU[1{�oG BUILDING DEPARTMENT TOWN CLERK'S OFFICE co SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46684 Date: 8/12/2021 Permission is hereby granted to: Regan, Martin 415 E 52nd St Apt 10MC New York, NY 10022 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 85 Watersedge Way, Southold SCTM #473889 Sec/Block/Lot# 88.-5-56 Pursuant to application dated 8/3/2021 and approved by the Building Inspector. To expire on 2/11/2023. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector ®��oF sov��®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.deviin(a)-town.southold.ny.us Southold,NY 11971-0959 ® �® COUN N BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Martin Regan Address: 85 Waters Edge Way city,Southold st: NY zip: 11971 Building Permit#- 46684 Section: 88 Block: 5 Lot. 56 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GreenLogic LLC License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceding Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 2 Switches 4'LED P1 Exit Fixtures 11 Pump Other Equipment. 9.8kW Roof Mounted PV Solar Energy System w/ (28) SPR-X21-350-E-AC Panels, 2 PV AC Disconnect, Sun Power Monitor, Sub w/220x3 215x1 Notes: Solar Inspector Signature: c Date: November 16, 2021 S. Devlin-Cert Electrical Compliance Form 65 UPSOUIyOIo q � &gq S7.4rD46 # TOWN OF SOUTHOLD BUILDING DEPT. co765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION'2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ' ] FINAL [ ] -FIREPLACE & CHIMNEY" [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: �- Lea A::1 cgmnv (JV DATE INSPECTOR B� �o�aoF soulyolo * TOWN OF SOUTHOLD BUILDING DEPT. o`�courmN� 765-1802 ANSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL Sb(.Alt— �': ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ =] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 942 DATE 10 Z$ INSPECTO •J AM E S J. S TOUT AIRCHITECT & Assoc. 2 GREG LANE E AST NORTHP0RTN. Y. 631 - 8 58 9388 Post Installation Letter October 6, 2021 RE: Regan Residence 85 Watersedge Way Southold, NY 11971 To Whom It May Concern: This letter is to confirm that as of this date October 6, 2021, I, James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels at the above listed address. The solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2020 NYSRC and 2020 NYSUCS building code and all related provisions.The installation of panels was done as per plan. Thank you for your cooperation in this matter. James J Stout ARE® A/�c ). T E" 44j a � � 33 yOQ' FIELD INSPECTION REPORT 'DATE FOUNDATION(1ST) ...........r..............`........ ;. ., `t, . • .. ( w rA FOUNDATION (2ND) J 77 ROUGH FRAMING& H PLUMBING INSULATION PER N.Y. STATE'ENDRGY CODE FINAL' ; S-41 t,- , -aL C-'' 0 w�77! z y TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 4F , Telephone (631) 765-1802 Fax (631) 765-9502 https://ww�v.southoldtownny.gov Date Received APPLICATION UIL I IT For Office Use Only D PERMIT NO. q�� Building Inspector. — 3 2021 g AUG Applicataons,.ah forms muyst_6'''filled out in their brit" ,4neornolete , '=_,, B D G DEQ. app`tications'will not pe=acce ted.`11 Fiere;tFietAp>`plicant is"not the oinrper,ate a wner'sA" 6riiati—fcarrie Pa e:2 shalFbe corn TOZV)°d OF SOIJTIIOLD Date:6/1/2021 OWNER(Si io PROpERTY�. Name:Eileen Regan _....._. . .... .....__.._....... ...__. .....__. SCTM#1000-^88-5T-5.6.._... _.._^__._.... ...^^.._..... Project Address:85 Watersedge Way, Southold,NY 11971 .. . .._.._-_ ___ __. ....._..... Phone#:646-734-4217_ Email:ekregan@aol.com Mailing Address:415 E. 52nd St Apt 10MC, New York NY 10022 ,`4ah ^.'e,G%,�a"'L,,Y tri CONTACTPERSBN; Name:Barbara-GreenLogic LLC_. .... .............._.... ....__._....^....... .^........... ..,..._._._...... _................,._^__.^..^._......____.. .._..... Mailing Address:97NorthSea Road, Southampton, NYJ1968 Phone#:631-771-5152 x117 Email:Barbara@Greenlogic.com4 DES#GN>PRQFESSIQIVIAL1111 �ORMA1`I®N; ' Name:James J. Stout Architect & Assoc. Mailing Address:2 Greg Lane, East Northport,_NY 11731 Phone#:631-858-9388 _ _ _ .._._.� Email:stouthub@jamesstoutarch.com C(�-NTRACI'QR�IN�FUR {✓ Name:GreenLoclic LLC Mailing Address:97 North Sea Road, Southampton, NY 11.96^8 Phone#:631-771-5152 Email:AM@Greenlogic.com__, ___— -, _•�:.,.,+, »„f^, ...... z >=s�,r a 1 ` -� �V��M �^�O S RUCTIO� © mak, erMsa f« s ' ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated cost of Project: 0 Other solar Panels $35,000 Will the lot be re-graded? ❑Yes RNo Will excess fill be removed from premises? ❑Yes RNo 1 �Regutailo "the of buildings, ' S� Q BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a-Dsoutholdtownny.gov — sea nd(@_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 1 7/30/2021 Company Name: I GreenLogic-LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance Address.: . 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION -(AII Information Required) Name: Eileen Regan Address: 85 Watersedge Way,Southold, NY 11971 Cross Street: Phone No.: 646-73474217 Bldg.Permit#: email: ekregan@aol.com Tax Map District: 1000 ection: 88 Block: 5 Lot: 56 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (28) SunPower SPR-X21-350-E-AC panels Ft (28) SunPower SPR-X21-350-E-AC micro inverters (1) SunPower PVS6 monitor System Size: 9.800kW Check All That Apply: Is job ready for inspection?: ❑YES , ❑✓ NO ❑Rough In OFinal Do you need a Temp Certificate?: EYES ONO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xisx gll� zJ PERMIT# Address: Switches Outlets GFI's I Surface Sconces H H's UC Lts r ; Fans Fridge HW Exhaust Oven W/D Smokes DW Mini Carbon "Micro -Generator Cooktop _..,� '- __ _ Transfer' . 8drt"�r w..sive.s„•a.c-.sm., e,v»m.w�.,„,xJ.. .Srcw...n.-,s en, _.9�i . +. .._ . , -v. _.. �...y....- •r-,+ter• � rr.,: n;-n>s.�ns..r.,;Y= -w-* uu-*- ,.4H�. �_ai ...-� �.+s_ --v,.,_+. Fa -mv a.0 •� AC AH Hood w Service �i,. ,.,t•'� i.k..�:,,Y' ix;' r}/^"'���. {q i it _,t.-. x �, •ir�? '.'1',�•,�s - Used AmpHave s” ' Special:,-,,,. Comments Iv " /-t'� C 1� �✓� �i7, ,t: V A-if— L" 9-�- 2- AlIpA nl ,ems G E [LOGIC® ENERGY July 30, 2021 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Eileen Regan 85 Watersedge Way Southold, NY 1000-88-5-56 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec.sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, Barbara Casciotta Account Manager rb1arLaC@Greenlogic.com GREENL 110771 5 .Gretenfi9c com Tel: 631.771.5152 Fax. 631.771 5156 ex SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S Service Rd ,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 x.. GREENLOGICO ENERGY November 18, 2021 ® 0 U NOV 2 J 2021 E " E Do The Town of Southold BUILDING DEPT Building Department TOWN OFSOUTHOLD 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Project Info: Building Permit No. 46684 Martin Regan 85 Watersedge Way Southold, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you have any questions about the installation. Sincerely, Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC o www.Green Logic,corn Tel: 631.771 5152 Fax 631 771 5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd ,Suite 3 200 S Service Rd ,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 DATE .��D• CERTIFICATE OF LIABILITY INSURANCE Fol/29/2021D THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske Brookhaven Agency,Inc. PHONE 631 941-4113 Fax 631 941-4405 100 Oakland Ave,Ste 1 E-MAIL Certificates@ brookhavena enc .com Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE NAIC# INSURER A.-Southwest Marine&General Insurance Co. INSURED INSURER B. Merchants Preferred Insurance Co. GreenLogic,LLC INSURER C:First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER 0.National Liability A Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE ®OCCUR DAMAGES(RENTED $i00,000 X Contractual Liability X X GL202100012922 01/3112021 01/31/2022 MED EXP(Any oneperson) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE s2,000,000 POLICY®JEST �LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000 000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2020 08/1112021 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY X AUTOS ONLY na UMBRELLALIAB HOCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I I RETENTION $ WORKERS COMPENSATION PER OTH- AND EMPLOYERSIA 'LBILITY Y/N OFFICER/MEMBETF I I FR ANY R PROPRIETOR/PARTNER/EX D7 ECUTIVE❑ N/A see seperate certificate E L EACH ACCIDENT $ (Mandatory In NH) E L DISEASE-EA EMPLOYEE $ Ifes,describe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ C NYS Disability D251202 04/11/20 04/11/21 Statutory Limits E Installation Floater/Property SML93076366 4/15/20 4/15/21 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached H more space Is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANYOFTHEABOVE DESCRIBED POLICIES BE CANCELLEDBEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD � � Workers' CERTIFICATE OF YTAT� �Olit3 �nsation NYS WORKERS' COMPENSATION INSURANCE COVERAGE ta�r 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Numberof Insured Greenlogic LLC 631-771-5152 97 North Sea Rd,Suite 3 South Hampton,NY 11968 1 c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of insured(Only required ifcoverage is specifically limited to Id.Federal Employer identification Number of Insured or Social Security certain locations,in New York State,i.e.,a Wrap-Up Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the,Certificate Holder) United Wisconsin Insurance Company TOWN OF BUILDING DEPARTMENT 3b.Policy Number of Entity Listed in Box"1a" 53095 ROUTE 25 SOUTHOLD,NY 11971 WC589-00169-020$Z 3c.Polic(effective period 02/28/2021 to 12/01/2021 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partnerstoricers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"12"for workers' compensation under the New Fork State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier'or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate'holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of'insurance only while the underlying policy is in effect. Please Mote:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory.coverage requirements of the New York State Workers'Compensation Lava. Under penalty of perjury,i certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named'inured has the coverage as-depicted on this form. Approved by: Alicia Christiansen Print name of authorized representative or licensed agent of insurance camer) Approved by: -� � Ack �.. (Signature) v (Date) Title. Assistant Director,of Sales Operations, Telephone Number of authorized representative or licensed agent of insurance carrier. 941-306 3077 Please Note,Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are,NOT authorized to issue it. ; C-105.2(9-17) www.wcbny.gov CNEW STAWorkers! CERTIFICATE OF INSURANCE COVERAGE TKE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured GREENLOGIC,LLC 631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 11968 1c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(onlyrequired if coverage is specifically 11mited tc 203801194 certain locations In New York State,l e.,Wm"p Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of-Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box"1a" Southold, NY 11971 DBL251202 3c.Policy effective period 04/11/2020 to 04/10/2022 4. Policy provides the following benefits: ® A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: ® A.All of the employers employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the Insurance carrier referenced above and that the named Insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described abbovee..�� Date Signed 417/2021 By widU( f (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that Insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer - IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that Carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law.it must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed BY (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note.Only insurance carriers licensed to write NYS disability and paid family leave benefits Insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1.insurance brokers are NOT authorized to Issue this form. DB420.1(10-17) IIQIfPiuiio1o2�0m1,«�'<<10�Q17)���i�I . ......... ir -Y X ,Zv '?T' N.- Vi W", s Suffolk County Executive' Orrice of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that MARC A CLEJAN -41 doing business as GREEN LOGIC LLC W having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules ............. olk,State of New York is hereby licensed to conduct business as a HOME and regulations of the County of Suff IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses NOT VALID,WITHOUT D)EPARTMENTAL SEAL U AND A CURRENT CONSUI�IER AFFAIRS ID CARD Director 4 A -'?, 1k .1777 r � Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIALi • 1 • UGE, NEWYORK 11788 r LA12/10/2007 . SUFFOLK COUNTY Master Electrician License .�� 'Ibis is tocertify thatROBERT SKYPALA doing business as GREENLOGIC LLC having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws,rules and regulations of the i County of Suffolk, of 1 1,•. Additional Businesses �.f 1 it WITHOUT DEPARTMENTAL SEAL ANDXCURRENT �. CONSUMERI. �•, Director • 4 •\:. � �uY;0�.' � ;. �ii'i�`�:5�`�� �' ;. �y\,j�ilr r ,,.. ,y l- �r�F �., A •;;�'r 1.,�. �' ,.{, A�G. y/,S� �\� f.� 1��.l y`�'• �r1,.��J A`IVdES J. S TOUT A RCIIITECT & Assoc . 2 G REG L ANE E AST NORTHPORTN. Y. 631 - 8 58 9388 I If U+tl%ot�- COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES Letter of Certification AS REQUIRED AND CONDITIONS Or July 21, 2021 �S8kH9L�FBiAiW�8�� ��T#8k6ifl�fd-FEA�4 RE: Regan Residence �VG 60ARC� yy�USTEES 85 Watersedge Way Southold NY 11971 To Whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 130-mph wind design load as per 2020 Residential code of NYS (RCNYS), 2020 building code of NYS (BCNYS) residential code, 2020 Energy conservation construction code of NYS (ECCCNYS)and the 2017 National Electric Code NFPA 7012017 National Electric Code, and the ASCE 7-16. The existing 2"x 8"@ 16"o.c. roof rafters will provide adequate support. Thank you for your understanding in this matter. ELECTRICAL 11 SPECTION REQUIRED James J. Stout Architect APPR QV AS NOTID �E0 ARC � T DATE: -Z 19 B.P:# � P( FEE: BY:. NOTIFY -BUILDING DE-.ARTMENT AT 765-1802'. 8 A TO 4 PM FOR THE ' FOLLOWING INSPECTIONS: 21 1. FOUNDATION - TWO REQUIRED � ,V4 FOR POURED CONCRETE ...� 2. ROUGH • FRAMI,iNG & PLUMBING 3. INSULATION 4. FINAL - CONSTR"Y'—,`� MUST �G�PACY BE COMPLETE ':_,- ,,;. USE �tI� ®� ALL�-CONSTRUCTION >--ALL MEET THE � E IS UNLAWFUL L REQUIREMENTS OF T HE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR, MUT CERTIFIC/4 'i DESIGN OR CONSTRUCTION ERRORS. 117 . 0CCUPA traentogic,LLC Approved Regan,Edeen 85 Watersedge Way Southold,NY 11971 Surface#A: Total System Size:9.800WV Array Size:8.050WV 1 dircuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker Azimuth:190" Ptch:40° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR X21-350-BLK-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:4T 1 3/8"X 15'5 5/8" Surface:51'10"X 18'5" Ma iG#:Invisimount Legend: 23 SunPower 35OW Panels SunPower Invisimount Rad • 42 Quick Mount E Lag 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface.4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: �aE° Apc 021 633 y0� lF OF NE'N Drawn By.MA Drawing#i of 8 Date:7/19/2021 REV:A Drawing Scale:118!'=1.0' -des, LOGIC GreenLogic,LLC Approved Regan,Efeen 85 Watersedge Way Southold,NY 11971 Surface#A: Total System Size:9.800WV Array Size:8.050kW 1 circuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker Azimuth:190° Pitch:40" N Monitoring System: SunPower Panel/Array S ctl catiorm: Panel:SPR-X21-350-®LK-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.1W Array:4T 1 3/8"X 16 5 5/8" Surface:51'10"X 18'5 Ma is#:Invisimount 147 Legend: ® 23 SunPower 35OW Panels SunPower Invisimount Rat • 42 Quids Mount E Lag B 8 2x8"Douglas Fa Rafter 16"O.C. Notes: VA INK I Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf EnginealArchitect Seal: ��RED ARC '�i 5 3. ,S p 0 (P 021633 yOQ lF OF NES Drawn By:MA Drawing#2 of 8 Date:7/19/2021 1 REV:A Y Drawing Scale:118"=1.0' LOGIC &eenLogfc,LLC Approved Regan,Efeen 85 Watersedge Way Southold,NY 11971 Surface#A: Total System Size:9.800kW Array Sine:8.050kW 1 circuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker Azimuth:190° Pdch:40" N Monitoring System: SunPower Panel/Army Specifications: Panel:SPR X21-350-BLK-E AC Racking:SunPower Invisimount Panel:61.39"X 41.18" 1 1 Array:47'13/8"X 15'5 5/8" Surface:61'10"X 18'5" Magic#:Invisimount Legend: 1 1 2 23 SunPower 350W Panels SunPower Invisimount Rag 42 Quick Mount E Lag 8 2x8"Douglas Fir Rafter 16"O.C. 2 Notes: \V \J/ \:1V4 Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf EnginealArchitect Seal: �AED AfjC cc 1r 0210" y0� rF aF I's E44 Drawn By:MA Drawing#3 of 8 Date:7/19/2021 REV:A Drawing Scale:1/8"=1.0' T .tet. LOGIC &ftnLogrc,LLC Approved Regan,Edeen 85 Watersedge Way Southold,NY 11971 Surface#B: Total System Size:9.800kW Array Size:1.750kW 1 circuit of 5 on a 20A breaker Azimuth-190° Pitch:40° Monitoring System: N SunPower Panel/Army S ctficaftons: Panel:SPR-X21-350-BLK-E-AC Racking:SunPower Invisimount Panel:61.39"X41.18" Array:17'4 7/8"X 5'13/8" Surface:2T 4"X 14'6" Magic#:Invisimount Legend: 5 SunPower 350W Panels SunPower Invisimount Rai • 9 Quick Mount E Lag B 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf En neer/Architect Seal: �kF-0 ARC C �j-q o21 b3"' yOQ, lF OF r1E`1� Drawn By:MA Drawing#4 of 8 Date.7/19/2021 REV:A Drawing Scale:1/4"=1.0' h: LOGIC GreenLopfc,LLC Approved Regan,Eileen 85 Watemedge Way Southold,NY 11971 Surface#B: Total System Size:9.800kW Array Sine:1.750kW 1 circuit of 5 on a 20A breaker II Azimuth:190° Pitch:40" Monitoring System: N SunPower Panel/Army S cfficatione: Panel:SPR X21-350-BLK-E AC Racking:SunPower Invisimount Panel:61.3W'X 41.18" Array:1 T 4 7/8"X 5'13/8" Surface:27'4"X 14'6" Ma k:#:Invisimount Legend: ® 5 SunPower 35OW Panels -� SunPower Invisimount Rail • 9 Quick Mount E Lag B 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: (SAE D A q �5 S 7 :ST �21633 TF OF tN-A Drawn By:MA Drawing#5 of 8 Date:7/19/2021 1 REV:A Drawing Scale:1/4"=1.0' i LOGIC GreenLog1c,LLC Approved Regan,Eileen 85 Watemedge Way Southold,NY 11971 Surface#B: Total System Size:9.BWWV Array Size:1.750kW 1 circuit of 5 on a 20A breaker Azimuth:190° Pitch:40" N Monitoring System: SunPower Panel/AS iflcadom: Panel:SPR X21-350-BLK E-AC Racking:SunPower Invisimount 3 Panel:61.39"X 41.18" Array:17'4 7/8"X 6 13/8" Surface:27'4"X 14'6" M ic#:Invisanount Legend: 5 SunPower 350W Panels Y- SunPower Invisimount Rad 9 Quids Mount E Lag B 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf EngineortArchitectSeal: ED ARC�i C9�� S J S 02163' yOQ TF OF NES Drawn By:MA Drawing#6 of 8 Date:7/19/2021 1 REV:A Drawing Scale: 1/4!'=1.0' No Vent Pipes Will Be Covered By The sotarArrav � Y LOGIC Legend: GreenLog fc,LLC Approved Regan,Edeen AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge 85 Watersedge Way per R202 definitions per R324.6.1 as per R324.6.2.1 Southold,NY 11971 Total System Size:9.800kW 1 circuft of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker 1 circuit of 5 on a 20A breaker Azimuth:190° Monitoring System: N SunPower I Panel/Array S Hicalions: 1 I1 Panel:SPR-X21-350-BLK-E AC I 1 I Racking:SunPower Invisimount IPanel:61.39"X 41.18" AP i I AP I Army:47'2"X 28'8" I I Surface:53'9'X 52'4" Meter i i i Magic*Invisimount I ——_ I API Legend: ----------------------- SVO 28 SunPower 35OW Panels SVO --__—_ I SunPower Invisimount Rad F51 QuickMount E Lag \IV/ SVO I 2x8"Douglas Fir Rafter 16°O.C. 1 I I I Notes: x1xI 1 xix x1xix Number of Roof Layers:1 1 I Height above Roof Surface:4" I Materials Used:Quick Mount,SunPower IAdded Roof load of PV System:2.84psf 1 I Engineer/Architect Seal: I o 0� �a U ARC `rri I 23 SunPower ,L I IA x INI 350W Panels I 5 SunPower r" I 350W Panels ��.q 02163' y0� TF OF N�`� Drawn By:MA Drawing#7 of 8 Date:7/19/2021 1 REV:A Drawing Scale:3132"=1.0' d' LOGIC &een1mgrc,LLC Approved Regan,Frleen 85 Watersedge Way !OB MATERIAL LIST Southold,NY 11971 Total System size:9.800kW 1 circuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker 1 circuit of 5 on a 20A breaker Azimuth:190° Material Listtg .. Rail Material List Monitoring System: N SunPower Pand/Army 3 citicadons: Panel:SPR-X21-350-BLK-E-AC Cast Aluminum hbuntingBlotkw/E tlackAluminumFlashing 5' Racking.SunPowerinvisimount 5j16"x7,18"EPDMSealing Plug 52 Panel:61.39"X 41.18" Array:47'2"X 28'8" 5/1.6"x5.5"Hex-plead Lag Screw 5. Surface:53'9"X 52'4" 5,11.6"x:25 Fen derWash er 5.1 Ma is#:Invisimount Legend: 28 SunPower 35OW Panels o— SunPower Invisimount Rai • 51 Quick Mount E Lag U B 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seat: ED ARC,y, J. ,sT C r Q &P.A 021635 OQ 9�F OF NES y Drawn By:MA Drawing#8 of 8 Date:7/19/2021 1 REV:A Drawing Scale:3/32"=1.0' EQUIPMENT---__..®.__-_--__.®..®_-_--_--_- QUIPMENT-­­­­­­­­------- EXISTING SERVICE PV-SA-1 34A�, AC-COMBINER PANEL 120/240, 1PH, 3W * a AC-CMB-1 (PV LOADS ONLY) —OB 200A V11 H KWH K PV-SA-2 0A • 79n µ I a e 1N i o i I c BKR-1 AC-DSC-1 AC DISCONNECT T BKR-2 PV-SA-3 BKR-3 MAIN I III A B PV-SA-4 BKR�4 FUSED FL N cc N TYPICAL PV MODULE WITH INTEGRAL DC/AC INVERTER EGC EXISTING AC PANgLEXISlING I GEC LI Ii------------L---------------- GEC 6 cu 9.8OOkW DC 8.960kW AC PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Regan Eileen ENLOGICOB GREr 85 Watersedge Way ENERGY Southold, NY 11971 1.) INITIAL SUBMITTAL WITH APPLICATION ELIMINATING THE C09T OF ENERGY Page 1 of 3 Drawing No: Regan-3LD1 Revision: 1 Revised: 5/27/21 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-X21-350-E-AC EN PHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-2 PV SUB-ARRAY SPR-X21-350-E-AC EN PHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 8-MODULES PV-SA-3 PV SUB-ARRAY SPR-X21-350-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES PV-SA-4 PV SUB-ARRAY SPR-X21-350-E-AC EN PHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC RANGE CURRENT VOLTAGE, NOMINAL PV-SA-1 2800 WATTS 211-264 VAC 11.39 A AC 240 V, AC PV-SA-2 2800 WATTS 211-264 VAC 11.39 A AC 240 V, AC PV-SA-3 2100 WATTS 211-264 VAC 8.54 A AC 240 V, AC PV-SA-4 2100 WATTS 211-264 VAC 8.54 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Regan, Eileen y GREENLOGICO 85 Watersedge Way EN El G Southold, NY 11971 ELIMINATING THE OST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION r Page 2 of 3 Drawing No: Regan-3LD1 Revision: 1 Revised: 5/27/21 - r_ EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, 60A, NEMA-1, FUSED; FUSE RATING: 60A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.) CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Regan, Eileen 85 Watersedge Way ENERGY Southold, NY 11971 ELIMINATING THE GIST 'OF ENERGY 1 ) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Regan-3LD1 Revision: 1 Revised: 5/27/21 1 f t j / /0 •00- i' f j .s. s, Q QQ� 1. 1> SUR VEY OF 03� J LOT 7 "MAP OF TERRY WATERS" CER TOFILED DEC. 29, 1958 FILE 61IO 2901 _ �`• � r � T A Y`VfE a y�v 03, �O 2 0, MARTIN REGAN �Q��v ElLEE� REGAN T WN OF SOUTHOLD , COMMCNWEAL TH LAND TITLE \, �, INSUH14NCE COMPANY SUFFOLK COUNTY, Y �N. `_,�',�_,._� �• 4 TITLE N0. RH - 97 - 1913 1000 — 88 �e 05 — 56 SCALE. r = 40 ; /00 �y�� JA13, 1998- gs. , c� ANY ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION �° �° � OF SECTION 7209 OF THE LAW YORK STATE EDUCATION LA `�� � EXCEPT AS PER SECTION 7209-SUBDIVISION 2. ALL CERTIFICAt low ; fE£'ON ARE VALV FOR TMS 144P AAD COMS TF 'OF Om-Y r��`;i ,� SA® AIAAP OR CODES SEAR Tom' SSED SEAL OF THE SURVEYOR / N [ :� NO 4 6l B WHOSE SIGNATURE APPEARS HEREON AREA '�y�5� S�. f$. to tie lineADDITIONALLY TO COMPLY WITH.,SAID LAW THE TERRA ALTERED BY" 411FECONIC S V �' &p.C. a� MUST BE USED BY ANY AND ALL' SURVEYORS UTILIZING A COPY 15161 765 - 502 • Fp OF ANOTHER SURVEYOR'S MAP. TERMS SUCH AS 'INSPECTED'AND P. 0. BOX 909 IAiV D - °BROUGHT-TO DATE' ARE NOT !N'COMPLIANCE WITH THE LAW. 1230 TRA VELER S - SOUTHOLD, 'N.Y. 11971 97 - 413 ' X S U ISI POWER' X-Series: X21-350-BLK I X21-335-BLK I X20-327-BLK SunPower' Residential AC Module Built specifically for use with the SunPower Equinoxi"'system,the only fully integrated solution designed,engineered and warranted by one manufacturer. Maximum Power. Minimalist Design. 00! Industry-leading efficiency means more power and savings per available space.With fewer modules required and hidden microinverters,less is truly more. Highest Lifetime Energy and Savings. Designed to deliver 60%more energy over 25 years in real-world conditions like partial shade and high temperatures.' 156^^. -. . .. ... . ....... ........ .. ......... _._. _. Fundamentally Different. And Better. v °' �p t° 60% T Iowa: more v C eow lifetime v • ani energy RConventional Module,- 70% N (30% The SunPower Maxeon"Solar Cell Years of operation • Enable_hiffhes e=ticiene✓ 1%odWes available. t r .r tat ed. _ I rty Best Reliability. Best Warranty. Pat n d solid rreizil foundation Peve.._s Lr iva� and a cn With more than 25 million modeles deployed around •;, .,..,• the world,SunPower technology is proven to last.That's why we stand behind our module and microin'•✓erter with the industrys best 25-year Combined Power and Product Warranty,including the highest Power Warranty >, in solar. Factory-integratedMicroinverter • dim; l.er,faster<nstaiiaron • Irre�rated w-ire r�tarta�;errte=•:t, v �y� rapid_znu dowrt a - 0 6� SunPower12% • Engineered and:alibrr+ted by sxa; more UnPower?or:Sijn:otowerrrodr:.- W 8f,9' Conventional Module power 'in year s 25 20 Years of operation X-Series:X21-350-BLK I X21-335-BLK I X20-327-BLK SunPowerl Residential AC Module Inverter Model:Enphase IQ 7XS(IQ7XS-96-ACM-US) @240 VAC @208 VAC ­1.1111 11���­­­­........................­....................­­­..................... ........................................__............................................__.......... ................................................................................................... ................. Peak CumW Power 320%,A 320 VA MaY.Contritio-us Outour Power 315 VA 315 VA Nom (L.-L)Vblirage/Range2 IV) 240 211-264 208/183-229 ........................——-----............ .................................................... .................... ............................... ........................................... ............. Max.Crin6nuous Output r C-.jrr,?rlr(A) 1.31 1.51 May..Units per 20 A(LL)Branch..Circuit." 12(singe phase) 10(two Pole)wye ............... .......... CK Vv'eighted Efficiency 97.5% 97 00/1 Nom.Frtquerry 60 Hz ................................................... Extended Frequerjcy Ran" 47-68 Hz ............... ....... ....... ................................................................ .................................................................................................................................. AC Short Circuit Fault Ct.in ent Over S Cyder 5.8 A rms Overvoltage Class Al­­P(_,t III AC Port Barkfeed Current 18 mA ............................... .............. ............................ Power Factclr Setting 1.0 .......... ................ ...................... ........................................ Powe,r Factor(ai)n tab:e) 0.7 lead./ 0.7 .......... .......... ............................................. ................................. ................... No active phase balancing for three-ptaseinsta1aTions .......... ...................................................... —------------__­____........................................................ .......... .................................................... ........................... )(21-350-BLK-E-AC X21-335-BLK-E-AC X20-327-BLK-E-AC 25-year limited power warranty Warranties 25-year limited product warranty '35 W ................... .......... Nom.Power-,(Pnom) 350 W - 327 W ................................................................................ ............. ............................. ............................................................................... ................................_.............................................................................................................................. UL 1703 Power-:of. 5/-0% +51-0% +5/-U% UL 1741/IEEE-1547 Certifications 204%, 1 Module Efficiency 21.S% 21.091, UL 1741 AC Module(Type 2 fire rated) and iTemp.Coef.(Power) -0.29%/'C -0.29"WIC -0.29%/,C UL 62109-1/IEC 62109-2 Compliance FCC Part 15 Class B Three bypass diodes ICES-.0003 Class 8 Shade Tol. Integrated module-level maximum CAN/CSA-C22-2 NO.107.1-01 power point tracking CA Rule 21(UL 17411 SA), (includes VoIUVar and Reactive Power Priority) UL Listed PV Rapid Shutdown Equipment Operating Temp. -4.0'Fto+185'F(-40*Ct +85'C) Enables installation in accordance with N'lax.A!"TILlient Ternp. 122'F(50°C) NEC 690.6(AC module) f4,,3xLoad Wind:62 psf,3000 Pat 305 kg/m2 front&back NEC 690.12 Rapid Shutdown(inside and outside the array) ,, . Snrw:125 psf,6000 Pa,611 kgm2 front NEC 690.15 AC Connectors,690.33(A)-(E),'1 nc i I -nal Ree am ln�j- mm)dieter hail at 52 ma h(23 m/s)r �5-la ..................... .. .................................... When used with InvisiMourt racking and lnvisiMounL accessories (UL 2703): Module grounding and bonding through InvisiMount Solar Cells 96 Monocrystalline Ma>eorl Geri Ill • Class A fire rated When used with AC module Q Cables and accessories(UL 6703 arid h tempered glas5,,Mch Front GassHig anti-re-ective coating UL 2238)1: :................................... Rated for load break disconnect Environmental Rating Outdoor rated —----- ................................................. ................. .......... ..... ........................................................................................... ............... Frame Class I black anodized(highest AAMA rating) PID Test Potential-nd Uced degradation free ................ ......................... .......... .......... ............I-------.................. Weight 42.9 lbs;0 S.S kg) Recommended Max. 1.3 in.(33 mm) Module Spacing I SunPower 360 W compared to a conventional module or.same.sized (260 W,16" 46 efficient,appro)0.6m 4%more energy per watt{baser,' third-party moduie mm characterization and PvSim),i;.754/yrr slowerdegradadon(Campeau,Z.et al."SunPower (1.8 in.) Module Degradation Ue,"SunPower white paper,2013;- ofdal`aShEel Values tromwebsi es of top 10 manufacturer,per IHS,as of L 2 Based on search 30 finua?y2017. (41.2 K) 3#1 rank in"Fraunhofer PV D,arability initiative for Solar Modules:Part I"PVF-(h Power t1.2 In.) Magazine,2015.Campeau,Z.et al.'SunPower Module Degradation Rate,'SurrPower whit e paper.2013. 4 Faccori set to 1547a-2014 delaul,settings-CA Rule 21 dtfault Settings prof.e set during 393 mm commissioning.Seethe Equinox Installation Guide 9518101 for more information, 5 Standard Test Conditions(1000 W/mir irradiance,AM 1.5,25'C).NREL calibration standard:SCIMS current,LACCS FF and voltage.All DC voltage is fully contained within the module. 6 This product is UL Listed as F:PSE and conforms with NEC 2014 and NEC 2017 690.12; 437 mm and C22.1-201;Rule 64-218 Rapid Shutdown of FV Systems,for AC and DC conductors; (17.2in.) when installed according to manufacturer's instructions. See vivfw,suripo,.,ver.corTilfaf.,ts for more reference information, cr;,0 details,see extended datashee;www.suripower.com/clatasheets specifications For more, inrluded in this datasheet are subject tL change without f-lotice. E470= Wdul.F.r.P.�f­.­:Type 2 C"',W E Ro T12,018 SuriPovver Cc-f prration.Ail Rights Reserved.SUNPCWiER,the SUNPOWER logo arid LISTED S U N P C/ MAXEGN are registered crademards of SunPowler Corporation in the U.S,and other countries aswell.1 Please read the Safety and insiiiilfit:or):iiszrtjc:tic,,is ll,r oo.*,01;:5, 531946 RevA sunpower.Com - �Ge•.;dx' '„✓ �,»/�/9/rs�� %.h. � �” /i,✓��/i Hr1 •� �;'./ir///�.. �'j;, �\ el�����%//ji ''i�li�gi� • �%%/vel° 5��.�,»� v6 = '��µfl �%/-.. � ✓�a��„i/�/iii -:: _ ��\ r5 �����i/ ,�,i a: y ;r • Sirmp,e and Fast Installation �� � ..... lrezrated module--Io-r=I-rot,n 'g \ Pre-assembled mid and end C.arnos L..PV at:ng n id( amr,for ea.-r,I.:cerne-ir I"A .rd a'tv ,id-1.h f dlita es rcmsistenc,eve'l si�rrfrf',[ r. tl^�l ail '03Listed ':ntt rated,xr'cun ,1 Flexible Design rtckZ Design in Landscape and porlla',”, Re ;i".i c sy o, i Cle rr urager­eni ,r Oustomer Preferred Aesthetics -ccrule and#` nrount.n a,=stl-(°ti_-s Eyes: it cbsssyscerr ,esthetics Elegant Simplicity Fr r ium, ovi Pred er3esigr Rack l<anodized o Q r nt.- SunPower� InvisiMountTm is a Sr�nPower-designed I h igen n-A d3rraps and end camps rail-based mounting system.The InvisiMount system and cappe fltsn rai's addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. R-flIt`car Use' `it!-.SranPo ve: C)i=and AC mzoul.es The InvisiMount product was specifically envisioned and Ede,, it Cla ysre n agility and ae ;luetic C'ombi,� ,, r stir ps r c engineered to pair with SunPower rnodules. The resulting rro r ircrir,o ar:>p system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. :. sunower.com � . � . Power , End Clamo Rai:&Rail Splice Ground Lug Assembly End Cap Temoe attire -.40'C to 90'C(-�d0° to'9L'F) Component h.laterial Weigh. _.__......................._... ----.......................__._............._................................_..... _..........._._.......... --.._.... I.... 3000 Pa uplift 11 —_--- �ax.Load(LRFD) Mid Clamp Black oxide stainless steel:11SI 304 03 g(2.2 0�; 600u:a dcw•nforce _ ........—__.................. ..........................._............................................................_r. _...._......_........................... End Clamp Black an:odlzed alurtniru;rn alloy 6063-T6 110 g(3.88 oz) Rail &ack anodized aluminum alloy 6005-1'S 830 glm(9 o�if) Rail Splice Aluminum alloy 6005-75 830 On(9 o:..t) 25 year product warran y — — —..........-1.--- tar ar es Grour d Lug 304 stainless 106 5 g/rr;(3.75 0Z) y manty 5-zar finis^:v„ Assembly (A2-70 bolt,tir:-plated copper ug) i..........................-- ----...._.._.._...._....................................................._..._............................_,..........._..._........._...__... _. End Capp Black acetal(POfet)copolymer 10.4 g(0.37 oz) i..................... _.._..---._..........._.............._...............--.--------.....................;........................................_......--- UL 270,3 Listed j Cer ificaticrs Class A Fire Rated Composition Shingle Rafter Attachmer..t. Ap li, ion Compos uon Shingle Roof Decking Attachment '�` Curved and Fiat Tae Roof Attachmert Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturers documentation:, *Mro.ilP..frame that's compatible with the In;,•sitfotrnt system required for hardware interoperability. lei 2015 SunPower Corporation. All Rights P,e ser4ecl.SUNPOWER,the SUNPOWER logo,and INVI.SIMCit1NT are trademarks or registered trail^marks of SunPower Corporation. All other trademark.are the property of their respe,rive owner; D #509506 RevC s•mpnwer-im Specifications inducted in this datasht.e are subject to change witho!,notice. Document i f, a iTI t-ove S�Pr��1-t, Reduce Maintenance Costs SunPower EnergyLink—Plug-and-Play Installation An it!uit.ve rrnvnitorim 4 ebsitc f fr_,t l;_�,ou -`' This complete solution for residential and commercial nonitor ng and See a Visual m }at u 'orrrcr sites control includes the Sur-Power" PV S. pery sor 6(PVS6)which improves ?E'r'"lt teiy r ana�e hundreds of s:.es ��•e instal.'cn process,overall system reliability,and customer t Iec i t_cyst rn report exoerierrce. ,ca:e system issue_ and temotelYdrag.rose Compact footprint for improved aesthetics Dfagnos(,jssUes or ine Robust cloud connectivity and comprehensive local connectivity ar ill ru,v,• :;r r the n` ic.. , d ev i pis Rexible configuration of devices during installation Consumption metering - Revenue-grade production metering(pending) Web-based commissioning oil, / Remote diagnostics of PVS6 and inverters - Durable UL Type 3R enclosure reduces maintenance costs MLO:. Easy integration with SunPower eBQS Add Value for Customers �k Robust Cloud Connectivity W:-;h e Sun! e ver M(,nito`ing Systerrip Multiple options to maintain optimal custorrnersc.an See vvInat ther solar >/stern pro. each e c ,��s connectivity clay,month,a year ;r Hardwired Ethernet Oolimize cir sola? vestrnf-nt and save an �. Wi-Fi energy exper se Cellular backup See their energy use and t ioi�ed bil suvr:gs 4 Y See their sclar.systc.r_pe urniancr_ using tbe SunPower mor ':.orrr g ,)(�r) tc Ktbile app Data z he'­ SUNP WER a. SunPower Monitoring Websites PVS6 SunPower AC Modules i}I111t� 11911 - �- 11 Multiple communication options include Ethernet,Wi-R,and cellular. Number of SunPower AC modules 85 Terrrperature -22°F to+11 40*F(-30°C to+60°C) supported per PvS6 Humidity(maximum; 95%,no•-condensing High-speed internet access v a accessible intemet access router or switch • 100-240 VAC(L-N}50 or 60 I-lz Power 208 VAC(L-L in 3-phase),60 Hz 125-485 Inverters and meters • One channel of revenue-grade production metering Integrated Metering a -1 wo channels of consumption metering Weight 5.5 lbs(2.5 kg) Ethernet. LAN(or optional WAN)port Dimensions 11.8 x 8.0 x 4.2 in.(30.5 x 20.5 x 10.8 cm) PLC �C forSunPovver A,C;nodules Enclosure rating UL.5.OE Type 3l2 . FE 802.11 blgfn 2.4 GHz and 5 GHz Cellular LTE Cat-M113G tj m r 11gdee IEEE 8132.15.4 MRC,2.4GHz ISM hand Data Storage 60 days Customer site monitor us sunoolmeL,=ru _........ .--.---_................... _-.-............—_---..—_.............-._ Upgrades Au':ornatic flrrnware upgrades Partner site Pksmgmt.us sunoower.com Browsers Flrefox Safari,and Chrome Mobile devices IPhone',iPadl,and Android" Customer app 1.Create account online at:monitor,us.sunpower.com. 2.On a mobile device,download the SunPower M(mitor my, Warranty 10-year limited Warranty app from Apple App Stores""or Google Plapstore. 3.Sign in using accoun ema l and password. Certifications UL cUL,CE,Ul 61010 1 anti 2,FCC Fart 15(Class B) C C LIiiEDz= FCC Id:YAW529027 E503346