HomeMy WebLinkAbout46700-Z o�O�u1F 1 cpm. Town of Southold 10/9/2021 a 9� P.O.Box 1179 y 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42420 Date: 10/9/2021, ,THIS CERTIFIES that the building GENERATOR Location of Property: 1260 Koke Dr., Southold SCTM#: 473889 Sec/Block/Lot: 87.-5-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/6/2021 pursuant to which Building Permit No. 46700 dated 8/17/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Ostrosky,Deborah of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46700 9/22/2021 PLUMBERS CERTIFICATION DATED Auth rize Si na ure ��o�SOFF TOWN OF SOUTHOLD BUILDING DEPARTMENT y x ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46700 Date: 8/17/2021 Permission is hereby granted to: Ostrosky, Deborah 1260 Koke Dr Southold, NY 11971 To: install generator as applied for. At premises located at: 1260 Koke Dr., Southold SCTM #473889 Sec/Block/Lot# 87.-5-17 Pursuant to application dated 8/6/2021 and approved by the Building Inspector. To expire on 2/16/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-ALTERATION TO DWELLING $50.00 Total: $235.00 B ctor Town Hall Annex - ® Telephone(631)765-1802 54375 Main Road P.O.Box 1179 sean.deviin(-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To, Deborah Ostrosky Address: 1260 Koke Dr city-Southold st: NY zip. 11971 Building Permit#: 46700 Section: $7 Block: 5 Lot: 17 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Peconic Power Systems License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment. 14 kW Generac Generator, 16 Circuit Generac Panel /Transfer Switch Notes. Generator Inspector Signature: Date: September 22, 2021 S.Devlin-Cert Electrical Compliance Form OPSooyo� - # * TOWN OF SOUTHOLD BUILDING DEPT. couffov, 765-1802 _-INSPECTION ] FOUNDATION 1ST [ ] ROUGH PLBG'. [ ] FOUNDATION 2ND ` j- ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING' [ ] FINAL [ ] FIREPLACE & CHIMNEY - j ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: C�l ' OK DATE 1'74V INSPECTOR �- 4`E� ��0 50UTy� # # TOWN OF SOUTHOLD BUILDING DEPT." `ycourm, 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [- ] - SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINALbe4t, [ ]' FIREPLACE &-CHIMNEY [ ] FIRE SAFETY INSPECTION ` [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE,RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: ol -DATE I INSPECTOR FIELD INSPECTION REPOPIT DATE 'co NQS FOUNDATION (1ST) ----------- ------------- FOUNDATION•(2ND) ROUGH FRAKII NG,& y PLUMBING :. INSULATION.PER N.Y. y STATE ENERGY CODE FINAL , ADpZ`TIONA�.�Q1VY1�1��Tfi' ' . •' ` : a w0 w�o��BtrFfoc�cG, TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 104/1 �'" Telephone(631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny_gov o � � Date Received APPUCAMN FOR BUILM G PE N D ICS For Office Use Only [2 `� DD 1 U� PERMIT NO. Building Inspector: AUG - 6 2021 Applications and forms must be filled out in their entirety.Incomplete BUILDING DEPT° applications will not be'accepted. Where the Applicant is not the owner,an T01VV 'OF SOUTHIO D Owner's Authorization'form(Page 2)-shall be completed. Date: �D OWNER(S)OF PROPERTY: Name: .0,aQ ro'A. SCTM#1000- -- Project Address: "0 kok, SoJAo1dj A/Y 49.r.71 Phone#: 516_,2.;-D_ 1/3S Email:�� Mailing Address: 1,;L6.0 11ok,c. S,4 /✓ X1971 , CONTACT PERSON: Name: Mailing Address: Phone#: Email: "DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Ro`e/'1 S�o,ne.✓�GLi �iQ`co�:c. ®wrr/ s s��-•s Mailing Address:P� �- Phone#: SSG_ �� Emaaiilv�p�� DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other L✓ $ za /r Will the lot be re-graded? ❑Yes o Will excess fill be removed from premises? ❑Yes R1101, 1 PROPERTY INFORMATION Existing use of property: Intended use of property: Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes El No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of.the Town Code. APPLICATION IS HEREBYWADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to section 210.45 of the New York State Penal taw. Application Submitted By(print name): "`""""�'�� ❑Authorized Agent ❑Owner Signature of Applicant: UNWRiMi7MEOFNEWYOIK Date: �1lcC�ty �1 STATE OF NEWYORK) SS: ,(� I_ ,,� COUNTY OFS�Ur�F l ) (Db ` �`YW 1�V being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, I,(S)he is the C�0 t ` -��'GAOK- (Contractor,Agent,Corporate Officer etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief,and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this_q� �! day of A20ZLL Notary Public PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at 12j, �L- Sllna �io hereby authorize to apply on Mmehalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date I' r Lk -- bs Print Owner's Name 2 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD 4= ';, ' " ,;,'_,', =� Town Hall Annex-54375 Main Road - PO Box 1179 c' Southold, New York 11971-0959 Telephone (631)765-1802- FAX(631)765-9502 roaerrasoutholdtownny.gov—seand casoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/6/2021 Company Name: PeconicPowers stems Name:JOe Whitman License No.: ME-45056 email: Peconicpowersys@gmad.com Phone No: 631-383-8502 ❑x l request an email copy of Certificate of Compliance Address.: P.O Box 512 Cutchogue,New York 11935 JOB SITE INFORMATION (All Information Required) Name: Deborah Ostrosky Address: 1260 Koke Southold,New York 11971 Cross Street: MamBayview Road Phone No.: 613-734-5026 Bldg.Permit t-- 6 email: Peconicpowersys@gmail.com Tax Map District: 1000 Section: $ 7 Block: 55 Lot: BRIEF DESCRIPTION OF WORK(Please Print Clearly) 14 KW Generator Check All That Apply: Is job ready for inspection?: x❑YES NO ❑Rough In ❑Final Do you need a Temp Certificate?: ❑YES rx-jNO Issued On Temp Information: (All information required) Service Size 01 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑Service Reconnect ❑Underground❑Overhead #Underground Laterals ❑l ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xisx vl �igfEUt� BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD cm u Town Hall Annex-54375 Main Road -PO Box 1179 ^* Southold, New York 11971-0959 Telephone (631) 765-1802- FAX(631)765-9502 rogerr southoldtownny.gov—seandCa),southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8/6/2021 Company Name: PeconicPower Systems Name:Joe Whitman License No.: ME-45056 email: Peconicpowersys@gmail.com Phone No: 631-383-8502 ❑x l request an email copy of Certificate of Compliance Address.: P.O Box 512 Cutchogue,New York 11935 JOB SITE INFORMATION (AII Information Required) Name: Deborah Ostroskv Address: 1260 Koke Southold,New York 11971 Cross Street: Main Baywew Road Phone No.: 613-734-5026 BIdg.Permit#: email: Peconicpowersys@gmail.com Tax Map,District: 1000 Section: $ Block: Lot: BRIEF DESCRIPTION OF WORK(Please Print Clearly) 14 KW Generator Check All That Apply: Is job ready for inspection?: DYES [—]NO -[:]Rough In ❑Final Do you need a Temp Certificate?: ❑YES ©NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑Service Reconnect ❑Underground❑Overhead #Underground Laterals ❑1 02 ❑Fi Frame❑Pole Work done on Service? . ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.x1sx I PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans 'Fridge HW Exha fast Oven W/D Smokes DW Mini Carbon -Micro Generator Combo_ , _ `Cdoktop �- . ..,_ - _ - w - .Transfer ` AC �AH Hood Service Arrips" ' Have Used Special:, Comments "` VV 04 AllQ SURVEY OF PROPER9 AT BAYVMW TOWN OF SOUTHOLL SUFFOLK COUNTY, X IOW--87--0-17 SCALE' 1= 90' AP,RK 24 2018 SEPMWBER $, 2020 SFPMIIBER 14 2020 (IRRIGATION ONLY DWELL I NC, WELL IRRIGATION ONLY PUN—I G W 3ATTF—R KOKE DRIVE - (30') PUBLIC, WATER IN 5TREET SEL31.8' f EL.26.8' N25'56'50"E EOP 125.00" EOP OP WM UP PIPE 240':h � —385.00' O.A.-- Z� o m � G9� BER CURB Q � � � ' O GRA DRIVEYIAY OEX o o rn I CPf STONE PATIO nMBER CURB � �OMc. � W ' m � O O D e ,A, 32.3LP R1� WO/F I OWELLIN& iv QUEEN ( O WEL1f50�L + New OUT DECK n C P aur, WATER � SNOWM STo M 22.5' , 23.9' 1 FR. C U HOUSE ; 0 C FF EL 29.4' 16.0' I c I 24. 01 2.8' ci TIMBER � I O TB�etTe n 1 StY. FR. W In sru010— N j 40.3' sLoeP N GARAG uO I'M FF=27.8N TANK w LOOSE STONE 24.5' v I TIMeae TIMBER LAP rim PIPE FND. SZ5�56'S0"W BERwMoNGH/1M 25.00 EL22.55''°_ EL22.9' VACANT T°� I� Iy �pc � ro covE ^ 5 ourr�ol.o PUBLIC, ,� ME r WATER b ZGT 4 Ao.463't� .Y.s Ll AREA=12,875 sq.ft. s, P a 0 FAX (631, P.O. BOX 909 �- 1230 TRAVELER STREET I r ACORU® DATE(MM/DD/YYYY) �. CERTIFICATE OF LIABILITY INSURANCE 06/21/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE'POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CONTCONTACT Josh Mitchell Freedom Coverage Corp PHONE (631)709-2777 FVC No: 80 Orville Dr Suite 100 E-MAIL om NY Josh FreedomCovera e .c ADDRESS: Gay 9 _ _ Bohemia, NY 11716 INSURERS AFFORDING COVERAGE NAIC p INSURER A: Midvale Indernity Company 27138 INSURED INSURER B: Employers Insurance 11512 Peconic Power Systems LLC INSURERC: 315 Commerce Rd INSURERD: Cutchogue, NY 11935 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 00000166-77552 REVISION NUMBER: 4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER PM DIDY EFF MMlDDY EXP LIMITS YYYl A X COMMERCIAL GENERAL LIABILITY GLP1092481 05/28/2021 05/28/2022 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE N OCCUR PRENTED EMISES Ea occurrence) $ 100,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 1,000,000 �( POLICY❑JET F]LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED F I RETENTION$ $ B WORKERS COMPENSATION EIG4706645 02/03/2021 02/03/2022 STATUTE X ETH, AND EMPLOYERS'LIABILITY ANY PROPRIETORIPARTNER/EXECUTIVE YIN E.L.EACH ACCIDENT $ 1,000,000 OFFICERIMEMBER EXCLUDED? NIA (Mandatory In NH) LEL.' EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below EL'DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) As pertains to insureds operations CERTIFICATE HOLDER CANCELLATION Town of Southhold- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. Town Hall Annex 54375 Main Road P.O. Box 1179 AUTHORIZED REPRESENTATIVE Southold, NY 11971 JCM ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Printed by JCM on June 21,2021 at 09:01 AM APR VED AS NOTED DATE:- FEE:-,236'16b BY- NOTIFY BUILDING DEPARTMENT, AT OCCUPANCY OR 765-18(2• SAM TO 4PM FOR-THE USE IS UNLAWFUL FOLLOWING INSPECTIONS: , 1. FOUNDATION - TWO REQUIRED- FOR EQUIRED WITHOUT CERTI�ICA� FOR POURED CONCRETE 2. ROUGH -,FRAMING & PLUMBING )F OCCUPANCY 3. INSULATION 4: FINAL - CONSTRLI-TinN MUST BE COMPLETE F-`- ' 0. ALL,CONSTRUCTrr\ SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES ELECTRICAL AS REQUIRED AND CONDITIONS OF INSPECTION REQUIRED Q01 IT ^ 5 �G BOAR USTEES r 6ENERAC° I tC/1 7/2® kw GUARDIAN® SERIES Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating • True Power" Electrical Technology Models 006240-0, 006241-0, 006247-0 (Steel - Bisque) - 14 kW 60 Hz • Two Line LCD Multilingual Digital Models 006242-0, 006248-0 (Steel - Bisque) - 17 kW 60 Hz Evolution TM Controller (English/Spanish/ Models 006243-0, 006249-0 (Aluminum- Gray) - 17 kW 60 Hz French/Portuguese) Models 006244-0, 006250-0 (Aluminum- Gray) -20 kW 60 Hz • Two Transfer Switch Options Available: 100 Amp Pre-Wired Switch or 200 Amp Smart Switch. >: See Page 4 for Details. • Electronic Governor External Main Circuit Breaker, System Status & <, ,a, Maintenance Interval LED Indicators • GFCI Duplex Outlet (17 &20 kW units only) _" +"''' NIERAr. • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Composite Mounting Pad • Natural Gas or LP Gas Operation a&S QUIEKEff LISTED • 5 Year Limited Warranty Note:Quiet-Test'only available on 17&20 kw units. • Capability to be installed within 18" (457 mm) Note CUL certification only applies to unbundled units and units packaged with pre-wired switches. of a building* Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN&PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing, reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at±1%. systems will provide superior performance. O TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit, from the utility quality power. This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro-chip based appliances,such as variable speed HVAC systems. O GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED v NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC GENERAC® 14/17/20 kW features and benefits Engine •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. • Quiet Test'" (17&20 kW units only) Greatly reduces sound output and fuel consumption during weekly exercise,compared to other brands. •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. ' •Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator •Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. -Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. •Displaced phase excitation Maximizes motor starting capability. •Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. •UL 2200 listed For your safety. Transfer Switch •Fully automatic Transfers your vital electrical loads to the energized source of power •Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) •DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items. •Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evoiutlonm Controls -Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. •Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. •Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. •Programmable seven day exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every week. •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. -Main line circuit breaker Protects generator from overload. •Electronic governor Maintains constant 60 Hz frequency. Unit -SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. •Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. •Small,compact,attractive Makes for an easy,eye appealing installation. Installation System •1 ft(305 mm)flexible fuel line connector Easy installation. •Composite mounting pad GENERACW 14/17/20 kW specifications Generator Model 006240-0,006241.0, 006242.0,006243.0,005248-0,006249.0 006244.0,006250-0 006247-0,(14 kW) (17 kW) (20 kW) :Rated Maximum_Continuous Power Capacity(LPj 4� m 14,000 Watts* 17,000 Watts" Rated Maximum Continuous Power Capacity(NG) _ _ 14,000 Watts* 16,000 Watts` _ V 18,000 Watts* _ a Rated'Voltage� __.w,_ _ 240 Rated Maximum Continuous Load Current—240 Volts(LP/NG) 583/58.3 70.8/66.6 83 3n5_ mTotal Harmonic Distortion rtr r_. _ _•.___ _ .T__:.-_ ______Less than 5% u µ T Ny,"� Less tfiari 5qo Nryry 4 " tT Less than 5% Ma_m Line Circuit Breaker _ _ 60 Amp 65 Amp _ 90 Amp Number of Rotor Poles _2 _ 2 �2 'Rated AC Frequency _._ _ _ 60 Hi .1 _tt__._ 60 Hz 60 Hz f Power Factor _ _ 1.0 _ 1.0 _ 1.0 Battery Requirement(not included] g �:_ _ _�_ ^� _ group 26R,12 Volts and 525CCA.Minimum.,—_ g t Unit Weight(lb/kg) µ435/197.3� 471/213.6(Steel);437/198.2(Aluminum) 451/204.6 ;_Dimensions291218 x 638 x 732 _( Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load** a _ �66 66 66 Sound output in d6(Aj at 23 ft(7 mj with generator in quiet Test""low-speed — (exercisemode`* ` 60 :.__ �_ �60. Engine Type of Engine;_ �w` uy _ _ y y _Y^ mrt 'GENERAC OHVI VTWIN, V GENERAC OHVI^VTWIN _,H LL y GENERAL OHVI VTWIN; Number of Cylinders 2 - -_ 2 _. _ 2 (Displacement � 992 cc 992 cc _� °'999 ccs Cylinder Block _ _ _ _ Aluminum w/Cast Iron Sleeve _ _ ;^Valve Arrangement . Vtie ry w V _ Overhead Valve _ _ M�Overhead Valved" R Overhead'Valve ; Ignition System _ _ __ _ _ Solid-state w/Magneto Solid-state w/Magneto _ Solid-state w/Magneto Goverrior System, _w � ,t � r_v µ_ Electronic .^_p _ _ _ Electronic=_ _,�vElectronicN, Compression Ratio 9.5.1 —9-5.1 9 5:1 t Starter, 12'Vdc 12 Udc 12 Vdc 011 Capacity Including Filter _ Approx.1.9 qt/1.8L _Approx.l.9 gU1.8 L Approx.1 9 gt/1.8 L Operating rpm_ 3,600 rvFuel Consumption Natural Gas ft3/hr(m3/hr) 1/2 Load 177(5.01) 193(5.47) 205(5.8) Full Load 279(7 9) 312(8.83) 308(8.72) Liquid Propane 0/hr(gal/hr)[I/hr] 1/2 Load 67.2(1 85)[6.99] 72.4(1.99)[7.53] 75.6(2.08)[7.87] Full Load __ __ 111.6(3.07)[11.61] _ 130(3 57)[13.53] 140(3.85)[14.57] -_pv.�.._,.__,.P..m..,.. r--Note Fuei pipe must 6e shed for full load.`Required fuel`pressure to generator fuel inlet at all load`ranges-3.5 7"water column(7-13 mm mercury]for natural gas,10-12"water column(19-22 mm. a mercury)for LP gas.`For Btu content,multiply ft3/hr z 2500(LP)S,it3/hr x 1000(NG),for Megajoule content,multiply m31hr_x 9315(LP),or m3/hr is 37.26(NG)w Controls r_ __ ,.w_ ._._ __ u_a_,. _.. _ 2-Line Plam_Text Mulhlln ual L'CD Drs la :,._. ._ Simple user interface far ease otoperation., -<_.______ ._._. _.�1 _ __. 9 _.Y___ _Pa Y" Mode Buttons Auto _ Automatic Start on Utility failure.7 day exerciser. Manuall p � � � __ Start with starter control,_unit stays on if etility!fafls,transfer to load takes place Off _ Stops unit.Power is removed.Control and charger still operate. t Ready to RuNMamtenance Messages ° 1 Standard_ f Engine Run Hours Indication _ Standard y Programmable start,delay between_2-1500 seconds__. ^_^_ - M� _T' +" Stand rd,(programmable by dealer nnlyj _, p— Utility Voltage Loss/Return to Utility Adjustable _ _ _ _ _ _ _ From 140-171 V%19.0-2.16 V _ Future Set CapableExerciser/Exercise Set Error Wammg M r v_ �pµ„ 44 R 'StandaNN w a Run/Alarm/Maintenance Logs _ 50 Events Each En i6 Start Sequence - � �� -- � C clic crin:- 16 sec on,7'rest�90 sec maximum duration Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped _ Charger FauIVMissing AC Warning _ _ ~Standard Low Battery/Baitery Problem Protection q14 BBattery_Condition Indication ^ x ry �N� Standard Automatic Voltage Regulation with Over and Under Voltage Protection Under-Frequency/Oveiload/Stepper Overcprrent Protection ��"� n q dStandard w Safety Fused/Fuse Problem Protection Standard r Automatic Low Oil Pressure/High Oil Temperature Shutdown " Standard Overcrank/Overspeed(@ 72 Hz)/rpm_Sense Loss Shutdown Standard _ _ _ i High Engine Temperature Shutdown Internal FaulVlncorrect Wiring Protection (Common Fxternal Fault Capability _ M_ v� h Mx� w.. ,Standard Field Upgradable Firmware _ Standard **Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters Rating definitions-Standby Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,IS03046 and DIN6271). *Maximum wattage and current are subject to and limited by such factors as fuel Btu/megaloule content,ambient temperature,altitude,engine power and condition,etc Maximum power decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level,and also will decrease about 1 percent for each 6°C(10°F)above 16°C(60°F). ® GENERAL® 14/17/20 kW switch options PTe-wired Features Model 006240-0(14 kW) 006242.0(17 kW) available on 14&17 kW models only f_._.___ _. Noof Poles' _...� • Electrically operated,mechanically-held contacts for fast,positive Current Rating(Amps) _ _ 100__ 100 _ connections. ;Voltage Rating' A�)_b—.;w. �._ ,:r_250,_f 120/240,10 , Utility Voltage Monitor(Fixed)` • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 80% 80% resistive. -Dropout 60% _ 60% (Return to Utility' - _ r approx.15 sec., approx.l5_sec�r�_ • 2 pole,250 VAC contactors. Exercise weekly for 12 minutes" Standard Standard • 30 millisecond transfer time. ;UL Listed Total of Pre-wired Circuits 14 16 • Dual coil design. No.15 A 120 V 4 5 No.20 A 120 V 6 5 • Main contacts are silver plated or silver alloy to resist welding and sticking. No.20 A 240 V 1 1 • NEMA 1 (indoor rated)enclosure is standard on the pre-wired switch. No.30 A 240 V - - No.40 A 240 V 1 1 • Pre-wired 30 foot(9.1 meter)whip to connect to the provided 5 foot pre- No 50 A 240 v _ 4 1 wired whip and external connection box. f6i6it BYeakeF Proiecied—_ `� F 7 Available RMS Symmetrical • Pre-wired 2 foot(0.61 meter)whip,color coded to connect into the Fault Current @ 250 Volts- 10,000 existing electrical panel. *Function of Evolution Controller Dimensions Mechanical Dimensions a F Height Width Depth H1 H2 W1 W2 ' H2 u H1 in 23.5 26.4 8.3 12.6 6.3 mm 597 671.7 211 320.7 159.6 Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0-#14 2/0-#14 2/0-#14 FW-17 Wz—I SmaA Switch Features Model 006241-0(14 k N)/006243-0(17 kW)/006244.0(20 kW) • Includes Digital Power Management Technology standard(DPM). No:of Poles • Intelligently manages two air conditioner loads with no additional current Rating(Amps) _ _ _200 Voltage Ratin AC _ 120/240,iQ hardware. Utility Voltage Monitor(Fixed)' • Up to four more large(120/240 VAC)loads can be managed when -Pick-up 80% used in conjunction with Power Management Modules PMM"* _ -Dropout 60% 1 9 ( )' rReturn to Utili'``"""`��" ______.__�.�_..._. �approx. 3 sec • Electrically operated,mechanically-held contacts for fast,clean Exercise weekly for 12 minutes* _ _ Standard connections. (UL~~Lrsted � _,,__ _ ._ : ______. _..__ _. _.� Standard'- Enclosure Type _. _ �NEMA/UL 313 • Rated for all classes of load,100%equipment rated,both inductiverWiths_fand Rating-(Amps) � :' ` " � � "";22;000 ` �= and resistive. Lug Range 250 MCM-#6 • 2 pole,250 VAC contactors. *Function of Evolution Controller • Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. • NEMA/UL 311 aluminum outdoor enclosure. W' • Main contacts are silver plated or silver alloy to resist welding and sticking. "Note:PMM starter kit is required prior to using the modules. H2 H1 Dimensions 200 Amps 120/240,1H Open Transition Service Rated Height Width H1 H2 W1 W2 in 27 24 30.0 114 1 13.57.09 mm 692.0 762.4 289.0 343.0 180.0 °EPTH W2 • GENERAC® 14/17/20 kW available accessories Model# Product'. = Description 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R j wet cell battery for use with all air-cooled standby product. 006212-0 ; Cold Weather Kit If the temperature regularly falls below 32°F(0°C),Install a cold weather kit to maintain optimal battery and oil temperatures. Kit consists of a battery warmer and oil filter heater with built-in thermostats. I ;Auxiliary Transfer Switch Contact ?The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load 005621-0 ; Kit you may not need.Not compatible with 50 amp pre-wired switches. 1 i The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers 005839-0-Bisque Fascia Base Wrap Kit* I ]a sleek,contoured appearance as well as offering protection from rodents and insects by covering the 005666-0-Gray (Standard on 20 kW) I . . j t IifUng holes located in the base. j 005703-0-Bisque * If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from 005704-0-Gray Paint Kit 1,future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006484-0-14&17 kW°pYieM � I Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine 006485-0-20 kW = Scheduled Maintenance Kit maintenance on a Generac automatic standby generator. { i 005928-0 Wireless Remote Completely wireless and battery powered,Generac's wireless remote monitor provides you with instant status Information without ever leaving the house.Not compatible with CorePower or EcoGen systems. The PMM Starter Kit consists of a 24 VAC,field installed transformer that enables the use of the 24 VAC 006199-0 PMM Starter Kit Power Management Modules(PMMs)and one PMM.The standard controller(without starter kit)can ! control two HVAC loads with no additional hardware.Not compatible with pre-wired switches. ; Power Management Module(50 Power Management Modules are used in conjunction with the Smart Switch to Increase its power 006186-0 management capabilities.It gives the Smart Switch additional power management flexibility not found in 3 Amps) =any other transfer switch.Not compatible with pre-wired switches.Note:PMM Starter Kit required. ! I Generac's Mobile Link allows you to check the status of your generator from anywhere that you have 006463-1 j Mobile Link- access to an Internet connection from a PC or with any smart device.You will even be notified when a change in the generators status occurs via e-mail or text message. ry� � l *Note:Bisque kits are used in conjunction with steel enclosures.Gray kits are used in conjunction with aluminum enclosures. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions, DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES 637 6 mm [25.1 in] [47. mm [47.9 in] Model UPC 006247-0 696471062472 006240-0 696471062403 006241-0 696471062410 1288mm 006248-0 696471062489 [28 B in] 006249-0 696471062496 006242-0 696471062427 ID amL 0 ,;y ;,r 1,� ,, ;. ,1 006243-0 696471062434 777 006250-0 696471062502 642 mm 006244-0 696471062441 [25.3 in] 1226 mm [48 3 in] LEFT SIDE VIEW FRONT VIEW GENERAC® Generac Power Systems,Inc. • S45 W29290 HWY.59, Waukesha,WI 53189 • generac.com 02013 Generac Power Systems,Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 01979908B`-6 Printed In U.S.A.12/11/13