HomeMy WebLinkAbout1000-50.-1-21 OFFICE LOCATION: rjf soyo MAILING ADDRESS:
Town Hall Annex P.O. Box 1179
54375 State Route 25 Southold, NY 11971
(cor.Main Rd. &Youngs Ave.)
Southold, NY 11971 Telephone: 631 765-1938
LOCAL WATERFRONT REVITALIZATION PROGRAM
TOWN OF SOUTHOLD
MEMORANDUM
To: Leslie Weisman,Chair
Members of the Zoning Board of Appeals
From: Mark Terry,AICP
Assistant Town Planning Director
LWRP Coordinator
Date December 13,2021
Re: LWRP Coastal Consistency Review for ZBA File Ref PANTS VIEW,LLC#7587
SCTM No. 1000-50-1-21
PANTS VIEW, LLC #7587 — Request for Variances from Article XXII, Section 280-116A(1); Article XXIII,
Section 124; and the Building Inspector's August 3, 2021 Notice of Disapproval based on an application to
demolish and reconstruct a single family dwelling; at 1) located less than the code required 100 feet from the top
of the bluff; 2) located less than the code required side yard setback of 15 feet; 3) more than the code permitted
maximum lot coverage of 20%; located at: 2022 Hyatt Road, Southold,NY. SCTM No. 1000-50-1-21.
The proposed action has been reviewed to Chapter 268,Waterfront Consistency Review of the Town of Southold
Town Code and the Local Waterfront Revitalization Program(LWRP)Policy Standards. Based upon the
information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the
records available to me,the proposal is recommended as INCONSISTENT with the below LWRP policies.
Policy 1. Foster a pattern of development in the Town of Southold that enhances community character,preserves
open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and
minimizes adverse effects of development.
Although a decrease in lot coverage is proposed to 21.1 percent,the proposed lot coverage exceeds the
maximum of 20 percent in areas prone to impacts from storms and is not supported. Overall, structure
within these areas should be minimized and set back from regulated natural features to the greatest
extent practicable.
Policy 4. Minimize the loss of life, structures, and natural resources from flooding and erosion.
The proposed 24' setback from the top of bluff to the single-family residence poses risks from erosion
and loss during storm events over time and is not consistent with this policy. Aerial analysis shows
that the bluff surface is heavily vegetated and relatively stable at this time, however,frequent storm
events that have caused the Town's shoreline to experience severe erosion(even when stable and
hardened)occurs. Setbacks to top-of-bluff lines mitigate future impacts to structures providing area
buffers between the hazards and structures.
Removing the structures from within the Coastal Erosion Hazard Area is supported by policy 4.
The installation of stormwater controls and a I/A OWTS is supported by policies 5 and 6.
Pursuant to Chapter 268,the Southold Town Zoning Board of Appeals shall consider this recommendation in
preparing its written determination regarding the consistency of the proposed action.
Cc: William Duffy, Town Attorney
I
BOARD MEMBERS Southold Town Hall
Leslie Kanes Weisman,Chairperson ®F ®U�y 53095 Main Road•P.O.Box 1179
®!®Dantes Southold,NY 11971-0959
Patricia ra Office Location:
Eric antes CA Town Annex/First Floor,
Robert Lehnert,Jr. ap 54375 Main Road(at Youngs Avenue)
Nicholas Planamentol�•COU Southold,NY 11971
http://southoldtownny.gov
ZONING BOARD OF APPEALS
TOWN OF SOUTHOLD RECEIVED 'EC-EIVED
Tel.(631)765-1809•Fax(631)765-9064
SEP 2 3 2021
September 23, 2021 Southold Town
Planning Board
Mark Terry, Assistant Town Planning Director
LWRP Coordinator
Planning Board Office
Town of Southold
Town Hall Annex
Southold,NY 11971
Re: ZBA File Ref. No. #7587 Pants View LLC
Dear Mark:
We have received an application to demolish (as per Town Code definition) and
reconstruct a single family dwelling. A copy of the Building Inspector's Notice of
Disapproval under Chapter 280 (Zoning Code), and survey map, project description form,
are attached for your reference.
Your written evaluation with recommendations for this posal, as required under the
Code procedures of LWRP Section 268-5D is reque d within 30 days of receipt of this
letter.
Thank you.
Very truly yours,
Leslie K. Weisman
Chairp rson
,,,.—
By:
Encl.
Survey/Site plan: Elizabeth Roberts Architects, dated August 2, 2021
FORM NO. 3
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
SOUTHOLD,N.Y.
NOTICE OF DISAPPROVAL
DATE: August 3, 2021
TO: Robert E. Herrmann(Pants View LLC)
1319 North Sea Road
Southampton,NY 11968
Please take notice that your application dated May 17,2021:
For permit to: demolish(as per Town Code definition)and reconstruct a single-family dwelling
at:
Location of property: 2022 Hyatt Road, Southold,NY
County Tax Map No. 1000—Section 50 Block 1 Lot 21
Is returned herewith and disapproved on the following grounds:
The proposed construction,on this nonconforming 33,119 sq.ft. parcel in the Residential R-40 is
not permitted pursuant to Article XXIII Section 280-124 which states lots measuring 20,000-
39,999
0 000-
39 999 square feet in total size require a minimum side vard setback of 15 fe maximum lot
coverage of 20%.
The dwelling will have a side yard setback of 10.1 feet and lot coverage oL21. %.
In addition,the single-family dwelling is not permitted pursuant to Article XXII Section 280-
116A(1),which states; "All buildings or structures located on lots upon which there exists a bluff
landward of the shore or beach shall be set back not fewer than 100 feet from the top of such
bluff."
The plan shows the dwelling located 10.9 feet from top of bluff.
Auth zed Si _
Note to Applicant: Any change or deviation to the above referenced application may require further
review by the Southold Town Building Department.
CC: file,Z.B.A.
Fee-$ Filed By: Assignment No.
APPLICATION TO THE SOUTHOLD TOWN BOARD OF APPEALS
AREA VARIANCE
House No.2022 Street Hyatt Road Hamlet Southold
SCTM 1000 Section 50 Block 1 Lot(s) 21 Lot Size 31,879 sf Zone R-40
I(WE)APPEAL THE WRITTEN DETERMINATION OF THE BUILDING INSPECTOR
DATED 8/3/21 BASED ON SURVEY/SITE PLAN DATED August 2,2021
Owner(s): Pants View LLC
c/o Anthony Bonsignore,Manager
Mailing Address: 290 Park Avenue South,8th Floor,New York, NY 10003
Telephone: 212-768-4500 Fax:212-768-7073 Email:
NOTE:In addition to the aboveplease complete below if application is signed by applicant's attorney,agent,architect,
builder,contract vendee,etc.and name of person who agent represents:
Name of Representative:En-consultants for(x) Owner( )Other:
Address: 1319 North Sea Road,Southampton,NY 11968
Telephone:631-283-6360 Fax:631-283-6136 Email:rherrmann@enconsultants com
Please check to specify who you wish correspondence to be mailed to,from the above names:
( )Applicant/Owner(s), (x)Authorized Representative, ( ) Other Name/Address below:
WHEREBY THE BUILDING INSPECTOR REVIEWED SURVEY/SITE PLAN
DATED August 2,2021 and DENIED AN APPLICATION DATED May 12,2021 FOR:
(x)Building Permit
( ) Certificate of Occupancy ( )Pre-Certificate of Occupancy
( ) Change of Use
( )Permit for As-Built Construction
( ) Other:
Provision of the Zoning Ordinance Appealed. (Indicate Article,Section,Subsection of Zoning Ordinance by
numbers.Do not quote the code.)
Article: XXII,XXIII Section: 280 Subsection: 116(A)(1), 124
Type of Appeal. An Appeal is made for:
(x)A Variance to the Zoning Code or Zoning Map.
( )A Variance due to lack of access required by New York Town Law-Section 280-A.
( )Interpretation of the Town Code,Article Section
( )Reversal or Other
A prior appeal(x) has, ( ) has not been made at any time with respect to this property,UNDER
Appeal No(s). see below Year(s). see below . (Please be sure to research before
completing this question or call our ofce for assistance)
Name of Owner. ZBA File#
1)#1567, 1972
2)#3818, 1989
3)#5772,2005
4)#5920,2006
REASONS FOR APPEAL (Please be specific, additional sheets mcry be used with preparer's
signature notarized):
1.An undesirable change will not be produced in the CHARACTER of the neighbor or a detriment to nearby
properties if granted,because:
See attached addendum.
2. The benefit sought by the applicant CANNOT be achieved by some method feasible for the applicant to pursue,
other than an area variance,because:
See attached addendum.
3.The amount of relief requested is not substantial because:
See attached addendum.
4.The variance will NOT have an adverse effect or impact on the physical or environmental conditions in the
neighborhood or district because
See attached addendum.
5.Has the alleged difficulty been self-created'? { } Yes,or {)4 No Why:
See attached addendum.
Are there any Covenants or Restrictions concerning this land? {>c} No { } Yes(please furnish a copy)
This is the MINIMUM that is necessary and adequate,and at the same time preserve and protect the character of the
neighborhood and the health,safety and welfare of the community.
Robert E. Herrmann
Signa of Applicant or Authorized Agent
(Agent must submit written Authorization from Owner)
Sworn to before me this 15th day
of September —2021
N is
KIM H . STEPHENS
NOTARY PUBLIC
STATE OF NEW YORK
COMMISSION N0 . 5015931
QUALIFIED IN SUFFOLK COUNTY
EXPIRES AUGUST 2025
REASONS FOR APPEAL ADDENDUM FOR
PANTS VIEW LLC
2022 HYATT ROAD
SOUTHOLD,NY
SCTM#1000-50-1-21
1. Relief is requested from §280-116(A)(1) and §280-124(B) for additions and alterations to a
preexisting, nonconforming, 1 and 2-story dwelling situated less than 100 feet from the top of
bluff and less than 15 feet from the northerly side lot line, respectively. Relief is also requested
from §280-124(B) for total lot coverage greater than 20 percent. It should be noted that although
only existing decks/porches and the 459 sf, 1-story portion of the house—and thus less than 25%
of the 1,853 sf footprint'of the existing habitable dwelling structure—are in fact being demolished,
the Building Department has characterized the renovation as a demolition pursuant to §280-124,
which defines "demolition" as the "removal of a structure or portion thereof, where the total cost
of the reconstruction of the structure or portion thereof exceeds 50% of the market value of the
existing sturcture before the start of removal."
Granting of the requested relief for the proposed renovations will not produce an undesirable
change in the character of the neighborhood, as nearly all of the neighboring properties throughout
the developed shoreline of Hyatt Road are characterized by principal and accessory dwelling
structures located substantially less than 100 feet from the bluff. The preexisting nonconforming
neighborhood character is the result of 1)many of the properties having been developed long prior
to the enactment of the 100' bluff setback, including the subject property, which was developed
prior to 1957 (see Pre-C/O No. Z-26467); and 2) variances that allowed for the development or
redevelopment of those properties or for the renovation and expansion of preexisting structures on
those properties. For example, in 1999, relief was granted for a porch addition located 25 feet
from the bluff at 1500 Hyatt Road, five lots to the north (Case No. 4733); and in 2007, relief was
granted for a dwelling addition located 17 feet from the bluff at 1600 Hyatt Road, four lots to the
north (Case No. 6048). And newly constructed dwellings located less than 100 feet from the bluff
were authorized at 1455 Hyatt Road in 2018 (Case No. 7148) and 1700 Hyatt Road in 2000 (Case
No. 4858), located two and three lots to the north, in respectively.
Although the +11-foot bluff setback to the nearest point of the proposed roofed-over, wrap-
around, wood deck on the west (waterside) and south sides of the dwelling would be less than
these prior approvals, this proposed setback represents an 11-foot increase in bluff setback to the
legally preexisting,
Robert E. Herrmann
Sworn to before me this 15th
day of September, 2021
KIM H . STEPHENS
NOTARY PUBLIC
STATE OF NEW YORK
COMMISSION NO . 5015931
QUALIFIED IN SUFFOLK COUNTY
EXPIRES AUGUST 2 , 20,45
partially covered deck to be removed, which has a current bluff setback of zero (0) feet (see Pre-
C/O No. Z-26467); and a 23-foot increase to the property's overall bluff setback, as the legally
existing spa (with accessory deck) to be removed currently extends up to 12 feet seaward of the
top of bluff(see C/O No. 29761). Therefore, the project will result in an increase in overall bluff
setback conformity relative to both the legally preexisting and permitted structures on the
property. The project would also result in the complete removal of all existing structural surfaces
(totaling approximately 340 sf) located within the Coastal Erosion Hazard Area.
An improvement in overall lot coverage conformity will also result from the project design, as
proposed decreases to the footprint of the habitable dwelling structure and attached decks/porches,
along with removal of the legally existing accessory garage (see C/O No. 18745), pergola (see
ZBA Case No. 5920), and spa (see C/O No. 29761), will result in a significant net decrease to the
existing nonconforming lot coverage from 26.1 to 21.1 percent. And the proposed 10.1-foot
minimum side yard setback to the renovated dwelling represents no change from the legally
preexisting minimum side yard setback of 10.1 feet between the northerly lot line and the existing
2-story portio of dwelling to remain. As there will thus be no change to the existing side yard
setback and also no change in height of the one-story portion of the dwelling to be reconstructed
over the existing foundation, there will be no adverse impact to the adjoining neighbor to the
north; and the dwelling structure will continue to be located more than 40 feet from the neighbor
to the south. Overall, with respect to potential impacts on both community character and nearby
properties, the project will result in net increases to bluff setback and lot coverage conformity and
no changes to side yard setback conformity.
2. Through their proposal to renovate and partially reconstruct the dwelling and replace the attached
waterside deck, the applicant is seeking the benefits of updating, modernizing, and increasing the
efficiencies of a dwelling structure that was originally constructed prior to 1957 and subsequently
altered and,expanded by piecemeal additions and renovations. But even though the dwelling will
be renovated or reconstructed within the same footprint and the proposed covered deck will be
located farther from the bluff than the existing deck, the existing dwelling is located entirely
within the 100-foot bluff setback, and the northerly side of the dwelling is located 10.1 feet from
the northerly side lot line where 15 feet is required. It is therefore impossible to undertake the
proposed work without variance relief. However, the project has been designed to limit the
variance relief necessary and in fact increase zoning conformity by 1) maintaining the existing
side yard setback; 2) decreasing lot coverage; 3) increasing the bluff setback to the primary
dwelling structure by 11 feet; and 4) increasing the property's ' imum bluff setback by 23 feet.
R be E. Herrmann
Sworn to before me this 15th
day of September, 2021
KIM H . STEPHENS
NOTARY PUBLIC
STATE OF NEW YORK
COMMISSION N0 . 5015931 2 1 P a g e
QUALIFIED IN SUFFOLK COUNTY
EXPIRES AUGUST Z , 20J
3. The required bluff setback relief of 89 feet is mathematically substantial, representing 89 percent
relief from the required 100-foot bluff setback. However, the proposed 11-foot setback to the
proposed waterside roofed-over deck represents more than a thousand percent increase to the 0-
foot bluff setback from the preexisting waterside covered deck to be removed. The required side
yard setback of 4.9 feet is mathematically substantial, representing approximately 33 percent relief
from the required 15-foot minimum side yard setback. However, the relief is not substantial in
fact because it represents the maintenance of the legally preexisting side yard setback to the
northerly side of the dwelling to remain, which has been present since prior to 1957. The required
lot coverage relief of 1.1 perecent is insubstantial, representing only 5 percent relief from the 20%
maximum allowable coverage and a 19 percent reduction of existing lot coverage (3,871 to 3,134
sD, thus resulting in a decrease in lot coverage from 26.1 to 21.2 percent.
4. The proposed project design and incorporated mitigation measures described below are intended
to minimize or eliminate any potential adverse impacts on the physical and environmental
conditions of the subject property and surrounding environment through their beneficial impacts
on treatment of septic waste; stormwater runoff control and recharge; and the environmental
quality of groundwater, adjacent surface waters, and the adjacent bluff, shoreline, and wetland
ecosystem.
a. The existing bluff, the property's natural protective feature, appears to be stable and well
vegetated, and the top of the bluff seaward of the dwelling structure is partially retained by
a legally preexisting retaining wall (see Town Coastal Erosion Management Permit No.
5519). Nevetheless, the project design will achieve 1) an 11-foot or more than 1,000%
increase in bluff setback to the primary dwelling structure, relative to the legally
preexisting attached covered deck having a zero-foot bluff setback; and 2) a 23-foot
increase in the property's overall bluff setback through permanent removal of the legally
existing spa having a bluff setback of negative 12 (42) feet.
b. The project design will result in a 737 sf or 19% decrease in existing lot coverage, thus
reducing the existing nonconforming lot coverage from 26.1 to 21.1 percent, as a result of
the proposed decreases in the footprint of the habitable dwelling structure and attached
decks/porches; and removal of the accessory garage,tpeg , and spa.
RobeHerrmann
Sworn to before me this 15th
r .
day of September, 2021
KIM H . STEPHENS
NOTARY PUBLIC
STATE OF NEW YORK
COMMISSION NO . 5015931
QUALIFIED IN SUFFOLK COUNTY
EXPIRES AUGUST 2 , 201 �_
3Page
c. The project design will result in the permanent elimination of approximately 340 sf and
thus all structural surface areas situated within the Coastal Erosion Hazard Area, as a result
of the proposed removal of the existing 492 sf attached covered deck, 105 sf brick patio,
49 sf spa and associated 137 sf accessory deck, all located partially or entirely within the
Coastal Erosion Hazard Area.
d. The existing conventional septic system will be removed and replaced with a low-nitrogen,
I/A sanitary system consisting of an I/A OWTS located at least 85 feet from the top of
bluff and leaching pools located more than 100 feet from the top of bluff and 250 feet from
the surface waters of Long Island Sound. Unlike conventional systems that are not
designed or equipped to treat nutrients such as nitrogen, I/A systems are designed to
significantly reduce nitrogen loading into the groundwater and ultimately surface waters.
e. A proposed stormwater drainage system is designed to capture and recharge roof runoff
from the renovated dwelling; surface runoff from the driveway; and backwash from the
existing swimming pool .
f. A project limiting fence will be installed to contain site disturbance and potential surface
runoff during construction.
5. The difficulty in meeting the required bluff and side yard setbacks is not self-created because the
existing nonconforming setbacks associated with the existing dwelling footprint were established
prior to 1957 and thus prior to all current zoning codes, as recognized by Pre-C/O No. Z-26467: It
may be argued that the difficulty in meeting the maximum lot coverage is self-created, as the
property was purchased by the applicants subsequent to establishment of the code-required bluff
setback, and thus it may be presumed that the applicant had actual or constructive knowledge of
this code requirement at the time of purchase.
Robert '. Herrmann
Sworn to before me this 15th
day of September, 2021
KIM H . STEPHENS
NOTARY PUBLIC
STATE OF NEW YORK
COMMISSION N0 . 5015931
QUALIFIED IN SUFFOLK COU N Y
EXPIRES AUGUST Z , 20
4Page
1
APPLICANT'S PROJECT DESCRIPTION
APPLICANT: Pants View LLC DATE PREPARED:September 15, 2021
1.For Demolition of Existing Building Areas
Please describe areas being removed:459 sf, one-storyportion of house (to existing foundation)to be
reconstructed: 56 sf one-story entry: 492 sf attached covered deck: 137 sf accessory deck: 49 sf accessory
spa: 226 sf accessory pergola:393 sf accesso[y garage: and 226 sf portion of 2nd floor roof and 66 sf
balcony,to be reconstructed.
II.New Construction Areas(New Dwelling or New Additions/Extensions):
Dimensions of first floor extension: +/-9'wide 762 sf attached covered deck
Dimensions of new second floor: No change
Dimensions of floor above second level: N/A
Height(from finished ground to top of ridge):34'-10"(max_, existing 2 stories to remain); 15'-6" (max., proposed
Is basement or lowest floor area being constructed?If yes,please provide height(above ground) reconstructed 1-story)
measured from natural existing grade to first floor: No
III.Proposed Construction Description(Alterations or Structural Changes)
(Attach extra sheet if necessary). Please describe building areas:
Number of Floors and General Characteristics BEFORE Alterations: One and two-story dwelling with
attached partially covered deck.
Number of Floors and Changes WITH Alterations:Same with reconstructed 1-story portion of house
and new attached covered deck in place of existing covered deck and one-story front entry(see attached
project description).
IV.Calculations of building areas and lot coverage(from surveyor):
Existing square footage of buildings on your property: 3,871 sf
Proposed increase of building coverage: -737 (proposed 3,134 sf) _
Square footage of your lot: 31,879 sf; 14,835 sf buildable land
Percentage of coverage of your lot by building area: 26.1% (existing); 21.1% (proposed)
V.Purpose of New Construction: To update- modernize and increase the efficiencies of a dwelling
structure originally constructed prior to 1957 and subsequently altered and expanded by piecemeal
additions and expansions.
VI.Please describe the land contours(flat,slope %,heavily wooded,marsh area,etc.)on your land
and how it relates to the difficulty in meeting the code requirement(s):
The position of the bluff on the property creates the difficulty with meeting a 100'setback from the top of
the bluff, and the location of the Coastal Erosion Hazard Area Boundary associated with the top of
the bluff limits the buildable land area to 14,835 sf,thus making it difficult to limit lot coverage to 20 percent,
even with a proposed significant reduction in coverage.
Please submit 8 sets of photos,labeled to show different angles of yard areas after staking corners
for new construction,and photos of building area to be altered with yard view.
4/2012
1
PROJECT DESCRIPTION
FOR
PANTS VIEW LLC
2022 HYATT ROAD
SOUTHOLD,NY
SCTM #1000-50-1-21
Remove existing 492 sf partially covered waterside deck (with pergola) from existing 1 and 2-
story single family dwelling, and construct 762 sf roofed-over, wrap-around deck, at least 11 feet
farther landward; reconstruct(in-place) approx. 226 sf portion of 2nd floor roof and 66 sf
balcony over proposed roofed-over deck; reconstruct(in-place) 459 sf 1-story portion of
dwelling; remove all existing accessory structures located seaward of top of bluff and/or within
Coastal Erosion Hazard Area, including Tx 7' spa, 137 sf deck, and 280 sf brick patio areas;
remove from landward side of house existing 56 sf 1 st floor front entry, 145 sf covered porch,
393 sf accessory garage, 226 sf pergola, and 1,454 sf brick patio around pool; construct on
landward side of house a 274 sf grade-level masonry patio and 1,005 sf grade-level masonry pool
patio; remove existing fencing and install new 4'high pool-enclosure fencing; install new
pervious gravel driveway in place of existing driveway; remove existing conventional septic
system and install new UA sanitary system; and install stormwater drainage system, all as
depicted on the site plan prepared by Elizabeth Roberts Architects, dated August 2, 2021.
QUESTIONNAIRE
FOR FILING WITH YOUR ZBA APPLICATION
A. Is the subject premises listed on the real estate market for sale?
Yes x No
B. Are there any proposals to change or alter land contours?
x No Yes please explain on attached sheet.
C. 1.)Are there areas that contain sand or wetland grasses? Yes
2.)Are those areas shown on the survey submitted with this application? Yes
3.)Is the property bulk headed between the wetlands area and the upland building
area? No
4.) If your property contains wetlands or pond areas, have you contacted the Office of the Town
trustees for its determination of jurisdiction?No Please confirm status of your inquiry or
application with the Trustees: Pending ZBA determination and if issued,please attach
copies of permit with conditions and approved survey.
D. Is there a depression or sloping elevation near the area of proposed construction at or
below five feet above mean sea level? No
E. Are there any patios, concrete barriers, bulkheads or fences that exist that are not shown
on the survey that you are submitting? No Please show area of the structures on a diagram
if any exist or state none on the above line.
F. Do you have any construction taking place at this time concerning your
premises? No If yes,please submit a copy of your building permit and survey as approved
by the Building Department and please
describe:
G. Please attach all pre-certificates of occupancy and certificates of occupancy for the
subject premises. If any are lacking,please apply to the Building Department to either obtain
them or to obtain an Amended Notice of Disapproval. Attached
H. Do you or any co-owner also own other land adjoining or close to this parcel?No If
yes, please label the proximity of your lands on your survey.
I Pleas. list pp esent use or operations conducted at this parcel Residential, 1 &2-story dwelling
dweling w attac a d2c s/porches,
spa pool pergola and garage and the proposed use same,w/renovated and partially reconstructed
dwelling and attached decks/porches and accessory pool (ex: existing single family,proposed: same
with age,pool or other)
September 15, 2021
Authot'I- signature and Date
a
FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No Z-18951 Date APRIL 3, 1990
THIS CERTIFIES that the building ADDITION
Location of Property 1295 HYATT ROAD SOUTHOLD, NEW YORK
House No. Street Hamlet
County Tax Map No. 1000 Section 050 Block 01 Lot 21
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JANUARY 31, 1989 pursuant to which
Building Permit No. 17848-Z dated FEBRUARY 16, 1989
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is
issued is ADDITIONS TQ EXISTING ONE FAMILY DWELLING AS APPLIED FOR.
The certificate is issued to RONALD Q. LOWELL
(owner)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
UNDERWRITERS CERTIFICATE NO. N-111155 - JANUARY 19, 1990
PLUMBERS CERTIFICATION DATED MAR. 16, 1990-MATTITUCK PLUMBING & HEATING
Building Inspector
Rev. 1/81
FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No Z-19081 Date MAY 25, 1990
THIS CERTIFIES that the building ADDITION & ALTERATION TO ACCESSORY
Location of Property 1295 HYATT ROAD SOUTHOLD N.Y.
House No. Street Hamlet
County Tax Map No. 1000 Section 50 Block 1 Lot 21
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated JANUARY 12, 1990 pursuant to which
Building Permit No. 18745-Z dated JANUARY 22, 1990
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is
issued is ADDITION AND ALTERATION TO EXISTING ACCESSORY GARAGE
The certificate is issued to RONALD & JEANNE LOWELL
(owners)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
UNDERWRITERS CERTIFICATE N0. N/A
PLUMBERS CERTIFICATION DATED N/A
Bui in Inspector
Rev. 1/81
rurun ivv.
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
PRE EXISTING
CERTIFICATE OF OCCUPANCY
No: Z- 26467 Date: 05/20/99
THIS CERTIFIES that the building DWELLING & ACCESSORY
Location of Property 2022 HYATT RD SOUTHOLD
(HOUSE NO. ) (STREET) (HAMLET)
County Tax Map No. 473889 Section 050 Block 0001 Lot 021
Subdivision Filed Map No. Lot No.
conforms substantially to the Requirements for a ONE FAMILY DWELLING
built prior to APRIL 9, 1957 pursuant to which CERTIFICATE OF
OCCUPANCY NUMBER Z- 26467 dated MAY 20, 1999
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is
issued is ONE FAMILY DWELLING WITH ACCESSORY GARAGE.
The certificate is issued to JEANNE C LOWELL
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. N/A
PLUMBERS CERTIFICATION DATED N/A
*PLEASE SEE ATTACHED INSPECTION REPORT.
c
xu-�
B ilding Inspector
Rev. 1/81
DV1LU 11Vb ULCt91�i1•tL L�1
TOWN OF SOUTHOLD
HOUSING CODE INSPECTION REPORT
LOCATION: 2022 HYATT RD SOUTHOLD
SUBDIVISION: MAP NO.: LOT (S)
NAME OF OWNER (S) : JEANNE C LOWELL
OCCUPANCY. SINGLE FAMILY JEANNE C IOWELL
ADMITTED BY: RONALD LOWELL ACCOMPANIED BY: SAME
KEY AVAILABLE: SUFF. CO. TAX MAP NO.: 50.-1-21
SOURCE OF REQUEST: JEANNE LOWELL DATE: 05/29/99
DWWELLING:
TYPE OF CONSTRUCTION: WOOD FRAME # STORIES: 2.0 # EXITS: 6
FOUNDATION: CEMENT BLOCK CELLAR: FULL CRAWL SPACE:
TOTAL ROOMS: IST FLR.: 2ND FLR. : 3RD FLR. : 0
BATHROOMS) : 3.0 TOILET ROOMS) : 0.0 UTILITY ROOMS) : B,9=
PORCH TYPE: DECK TYPE: WOOD DECK PATIO TYPE: BRICK
BREEZEWAY: FIREPLACE: 1 GARAGE:
DOMESTIC HOTWATER: YES TYPE HEATER: OFF BOILER AIRCONDITIONING:
TYPE HEAT: OIL WARM AIR: HOTWATER: X
OTHER:
ACCESSORY STRUCTURES:
GARAGE, TYPE OF CONST.: WOOD FRAME STORAGE, TYPE CONST. :
SWIMMING POOL: GUEST, TYPE CONST.:
OTHER:
VIOLATIONS: CHAPTER 45 N.Y. STATE UNIFORM FIRE PREVENTION & BUILDING CODE
LOCATION i DESCRIPTION i ART SEC
i
i
i
i
:
i
:
REMARKS: BP#8675_DECK CO#2-7121.BP#17848 ADDITIONS CO#z-18951 '8P#18745 ADDITION ALTERATION CO#Z-19081
INSPECTED BY: ^'z ' DATE ON INSPECTION: 05/20/99
GARY J FI TIME START: 9:40 AM END: 10:12
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-28237 Date: 02/28/02
THIS CERTIFIES that the building ALTERATIONS
Location of Property: 2022 HYATT RD SOUTHOLD
(HOUSE NO.) (STREET) (HAMLET)
County Tax Map No. 473889 Section 50 Block 1 Lot 21
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated FEBRUARY 19, 2002 pursuant to which
Building Permit No. 28101-Z dated FEBRUARY 21, 2002
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ALTERATIONS TO KITCHEN AND SECOND FLOOR BATHROOM AND INSTALLATION OF A
SLIDING GLASS DOOR TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR.
The certificate is issued to MARY BUTZ & DIANE S RAVITCH
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. N 586957 02/21/02
PLUMBERS CERTIFICATION DATED 01/14/02 MIKE JACOBI
Q4 co"
AuthorizdR Signature
Rev. 1/81
• FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-30968 Date: 06/07/05
THIS CERTIFIES that the building ADDITION & ALTERATION
Location of Property: 2022 HYATT RD SOUTHOLD
(HOUSE NO. ) (STREET) (HAMLET)
County Tax Map No. 473889 Section 50 Block 1 Lot 21
Subdivision Filed Map No. Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated AUGUST 15, 2003 pursuant to which
Building Permit No. 29761-Z dated SEPTEMBER 24, 2003
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ALTERATIONS & ADDITIONS INCLUDING COVERED FRONT PORCH, DECK, SUNROOM
& HOT TUB ADDITIONS TO EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.
The certificate is issued to MARY BUTZ & DIANE RAVITCH
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. 5028 08/27/04
PLUMBERS CERTIFICATION DATED 10/25/04 T.DEACY PLUMB. & HEATING
1 `
--Z ;
Aut ze Sign ure
Rev. 1/81
FORM NO. 4
TOWN OF SOUTHOLD
BUILDING DEPARTMENT
Office of the Building Inspector
Town Hall
Southold, N.Y.
CERTIFICATE OF OCCUPANCY
No: Z-34417 Date: 06/24/10
THIS CERTIFIES that the building SWIMMING POOL
Location of Property: 2022 HYATT RD SOUTHOLD
(HOUSE NO. ) (STREET) (HAMLET)
County Tax Map No. 473689 Section 50 Block 1 Lot 21
Subdivision Filed Map No_ Lot No.
conforms substantially to the Application for Building Permit heretofore
filed in this office dated. FEBRUARY 19, 2009 pursuant to which
Building Permit No. 34440-Z dated FEBRUARY 19, 2009
was issued, and conforms to all of the requirements of the applicable
provisions of the law. The occupancy for which this certificate is issued
is ACCESSORY IN GROUND SWIMMING POOL WITH FENCE TO CODE AS APPLIED FOR PER
ZBA #5772, DATED 10/27/05_
The certificate is issued to MARY BUTZ
(OWNER)
of the aforesaid building.
SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A
ELECTRICAL CERTIFICATE NO. 3000121 07/26/06
PLUMBERS CERTIFICATION DATED N/A
rr
/,/Author4ed S' nature
Rev. 1/81
4
TOWN OF SOUTHOLD,NEW YORK DATE.....Tune-...1.5, 1972
ACTION OF THE ZONING BOARD OF APPEALS
Appeal No. 1567 Dated June 1, 1972
ACTION OF THE ZONING BOARD OF APPEALS OF THE TOWN OF SOUTHOLD
To Charles & Evelyn Witherspoon Appellant
Private Road (Horton's Point)
Southold, New York
at a meeting Iof the Zoning Board of Appeals on June 15, 1972 the appeal
was considered and the action indicated below was taken on Your
( ) Request for variance due to lack of access to property
( ) Request for a special exception under the Zoning Ordinance
( x Request for a variance to the Zoning Ordinance
1. SPECIAL EXCEPTION.By resolution of the Board it was determined that a special exception ( ) be
granted,( ) be denied pursuant to Article ................... Section .................... subsection .................... paragraph
.................... of the Zoning Ordinance and the decision of the Building Inspector ( ) be reversed ( ) be
confirmed because 11150 P.M. (E.D.S.T.), upon application of Charles and
Evelyn WItherspoon, Private Road (Horton's Point), Southold, New
York, for a variance in accordance with the Zoning CRdinance,
Article III, Section 301, for permission to set off a lot with
insufficient width and area. Location of propertys north side
of Private Road (Hortonss Point), boAnded north by land now or
formerly of the applicants; easterly by land now or formerly of
Reed; south by Private Road; and west by Sardi. Fee paid $15.00.
2. VARIANCE.By resolution of the Board it was determined that
(a) Strict application of the Ordinance (would) (would not) produce practical difficulties or unnecessary
hardship because
SEE REVERSE
(b) The hardship created (is) (is not) unique and (would) (would not) be shared by all properties
alike in the immediate vicinity of this property and in the same use district because
SEER REVERSE
(c) The variance (does) (does not) observe the spirit of the Ordinance and (would) (would not)
change the character of the district because
SEE REVERSE
and therefore, it was further determined that the requested variance ( ) be granted ( ) be denied and
that the previous decisions of the Building Inspector( ) be confirmed ( ) be reversed.
ME REVERSE
PROV z0 BOARD OF AP
FORM ZB4 13L, -. . -tcc__te
v Marjor�MaDermott, Secretary
Southold Town Board of Appeals
4jrm('
an r of Ap als
After investigation and inspection the Board finds that
applicant requests permission to set off a lot with insufficient
width and area on the north side of PRivate Road (Horton's Point),
Southold, New York. The Board finds that this was a legal sized
lot at the time the contract was made and that this is a reasonable
request.
The Board finds that strict application of the Ordinance
would produce practical difficulties or unnecessary hardship;
the hardship created is unique and would not be shared by all
properties alike in the immediate vicinity of this property
and in the same use district; and the variance will not change
the character of the neighborhood and will observe the spirit
of the Ordinance.
THEREFORE IT WAS RESOLVED Charles and Evelyn Witherspoon,
Private Road, (Horton's Point), Southold, New York, be GRANTED
Permission-to set •off •a lot with insuffioient width and area on
property located on the- north side of Private Road• (Horton's
Point}, 39athold, ,•New York.
Vote '6f the Board: Ayes-- Messs,rs: Gillispie, Bergen, GRigoni
- - -
APPEAL FROM DECISIOJWF BUILDING INSPECTOR •
APPEAL NO. / ;I_r7l
DATE ....
TO THE ZONING BOARD OF APPEALS, TOWN OF SOUTHOLD, N. Y.
Samuels & Steelman Architects 25235 Main Road
1, fie)
.................................................................Of
Nome of Appellant Street and Number
Cutchogue NY
............................................................................................. ............................HEREBY APPEAL TO
Municipality State
THE ZONING BOARD OF APPEALS FROM THE DECISION OF THE BUILDING INSPECTOR ON
APPLICATION FOR PERMIT NO. ................................... DATED ..........
WHEREBY THE BUILDING INSPECTOR DENIED TO
Thomas C. Samuels, R.A.
............................................................
................i�a me of Applicant for permit
of
25235 Main Road Cutcho u
...............I........................1.................9...�,t...lil...................................................
) PERMIT TO USE Street and Number Municipality State
) PERMIT FOR OCCUPANCY
X) Permit to Construct
1295 Hyatt Road, Southold; A—Residence
1. LOCATION OF THE PROPERTY .....I..............iii.1;W.7aiimiR
7 Use District on Zoning Map
District 1000 Section 50 Block '- Lot 21
...Current Owner Jeanne Lowell
.....Mop No. L.
o"t,''N"'o''''''**...** --7—
prior Owner Witherspoon
2. PROVISION (S) OF THE ZONING ORDINANCE APPEALED (Indicate the Articli Sect.lorf, Sub-
section and Paragraph of the Zoning-Ordinance by-riumber. Do not quote the Ordinance.)
Article100-119 Section 2.A ,(I)
TYPE,OF,APPEAL Appeal is made herewith for, (please,check approPriatd box_)
'X) AVARi'VARIANCE tothe Zoning Ordinance or2o'ning Mop
A VARIANCE due to lack of occiis (State of New York Town-Low Chop. 62-'C6hs;""Lows
Art. 16 Sec. 280ASubsection3
4. PREVIOUS APPEAL A previous appeal ( (has not) been mode with respect to this decision
of the Building Inspector or with respect to this property.
Such appeal was ( ) request for a special permit
( ) request for a variance
andwas made in Appeal No. ...............................Dated ......................................................................
REASON FOR APPEAL
A Variance to Section 280A Subsection 3
X) A Variance to the Zoning Ordinance
is requested for the reason that
Form ZB1 (Continue on other side)
I V
DEC 19 r/
j T"'
7
M Southold Town Board of Appeals
MAIN ROAD - STATE ROAD 25 SOUTHOLD, L,I., N.Y. 11971
TELEPHONE (516) 765.1809
APPEALS BOARD
MEMBERS
GERARD P.GOEHRINGER, CHAIRMAN
CHARLES GRIGONIS,JR.
SERGE DOYEN,JR. February 9, 1989
JOSEPH H.SAWICKI
JAMES DINIZIO,JR.
Mr. Thomas C. Samuels, R.A.
Samuels & Steelman Architects
25235 Main Road
Cutchogue, NY 11935
Re:, Appl. No. 3818 - Jeanne C. Lowell (Variance)
Dear Mr. Samuels,:
The Town;',:as yox� may, know, ,ha-,_-recently effeetuated:=the new
Master (Zor iriq-);:41ah'-Update Art ele;'XI; ;Section:`10;fl.=139•:=2 was .
not; ncluded in' tl a Zoning` Update_ a id;.th 8 Department doer';noi:` „
Yi'ave ju'r'isdicirioii (durrently)• .at -tY s time. under; S:ection=',
100=119.'2. "
Weare providing the Building Inspector's office with a
copy of -this letter, and suggest that you or the property owner
follow-up with your pending Building Permit application with
-their office.
Please be aware that this position is subject to change if
you are not able to obtain your building permit and start
construction, pursuant to the appropriate permits, subsequent to
any additional amendments of the zoning laws.
Yours very truly,
GERARD P. GOEHRINGER
CHAIRMAN
lk
CC: Building Inspector' s office
Mr. Thomas J. Fisher, Building Inspector
APPEALS BOARD MEMBERS rp1�� ly�� Southold Town Hall
Ruth D. Oli,.a,Chairwoman ,`O 1p 53095 Main Road- P.O. Box 1 179
Gerard P. Goehringert t; Southold.NY 11971-0959
Vincent Orlando Office Location:
James Dinizio.Jr. • yo{�1 Town:annex/First Floor,North Fork Bank
Michael A. Simon pl,Y�,�U � � 54375 Main Road cat bungs A%enue)
' Southold.NY 11971
http://southoldtowii.north foi,k.net
BOARD OF APPEALS REC 1VED
TOWN OF SOUTHOLD .� 1.qpm
Tel.(631)765-1809- Fax(631)765-9064 Gc� 2 1 2005
Q.7
FINDINGS, DELIBERATIONS AND DETERMINATIOISOVh�Town
Clerk
MEETING OF OCTOBER 27, 2005
ZB File No. 5772—MARY BUTZ
Property Location: 2022 Hyatt Road, Southold CTM 50-1-21
SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this
application and-determines,that,this review falls under,the Type II category-of the State's List of Actions,
without an adverse effect 6106e environment if the project is implemented,as planned.
PROPERTY. FACTS%DESCRIPTION: The. applicant's: ,33',"119,sq. ft.' parcel has.25 =feet along- a=
private=right-of-way-wl'ic'h"eXtends1:74:feet from Hyatt,'Road, and,is improved with-a-single-family,
two-story dwelling,with"detached accesso y-garage, -Ko non fhe-site map-prepared;by Fairweather
Brown"Design Associates cJated,August 10, 2005.
BASIS OF APPLICATION: Building ;Department's July 29, 2005 Notice of Disapproval, citing
Section 100-33 in its denial-of an application fog a building permit to construct a proposed accessory
swimming (lap) pool at less than 40 feet from the code-required.front yard line.
FINDINGS OF FACT,
The Zoning Board of Appeals held a public hearing on this application on October 20, 2005 at which
time written and oral evidence were presented. Based upon all testimony, documentation, personal
inspection of the property, and other evidence, the Zoning Board finds the following facts to be true
and relevant:
AREA VARIANCE RELIEF REQUESTED: The applicants originally requested proposed swimming
pool as shown on the August 11, 2005 site map prepared by Fairweather-Brown Design Associates
at 12,5 feet from the southerly front lot line, and 91+- feet from the top of the bluff. Rather than to
submit a request for an additional variance under Section 100-239.4 (concerning the required 100 ft.
minimum from the top of the bluff), the applicant, on August 25, 2005, filed an amended site map
proposing the new pool greater than 100 feet from the top of the bluff (1027). The pool is also
shown at 12 feet from the southerly front lot line and 11'1"from the easterly side property line, at its
closest points.
REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and
personal inspections, the Board makes the following findings:
1
Page 2—October 27,2005
ZB File Ref.5772—Mary Butz
CTM 50-1-21
1. Grant of the variance will not produce an undesirable change in the character of the
neighborhood or a detriment to.nearby properties. The pool will be located in a fairly isolated portion
of the yard.
2. The benefit sought by the applicants cannot be achieved by some method, feasible for the
applicant to pursue, other than an area variance. There is limited area to locate the pool due to the
steep contour in the topography of this lot.
3. The variance granted herein is substantial. It represents nearly 70% reduction of the required
front yard setback.
4. The difficulty has not been self-created. The topography of the property creates limited
possibilities to locate an accessory pool, and the code requires a minimum of 100 feet from the top
of the bluff.
5. No evidence has been submitted to suggest that a variance in this residential community will
have an adverse impact on the-physical or environmental conditions in the neighborhood.
'6. Grant-of the requested relief is the minimum action necessary and and
:to enable .the
applicant,to enjoy the benefit of as swimming (lap) pool,-•while preserving';and protecting the character
of,,the neighborhood"nd fhe Health;safety 66 welfare;of the.,community.
'RESOLU-, ON-bF=,THE BOARD: In;considering all of.`tlie,above facto`rs_''and applyirig,the,balancing,,
test.,iand,&'_ ew Yarkv Town`Law.267=B,- motion was offered by Member Qinizio,seconded"by:.
.Chairwoman bliva,-and didly,carried, to
GRANT the variance as applied for, shown on the August 24, 2005 site map prepared by
Fairweather-Brown Design Associates, SUBJECT TO THE FOLLOWING CONDITIONS:
A. The 16' x 36' swimming or lap pool shall be open to the sky(unroofed); and
2. The owner shall maintain the existing landscaping which naturally screens the yard
areas.
This action does not authorize or condone any current or future use, setback or other feature of the
subject property that may violate the Zoning Code, other than such uses, setbacks and 'other
features as are expressly addressed in this action.
Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer, Dinizio, and Simon. (Member
Orlando was absent.) This Resolution w r s duly adopted (4-0).
JL&x " a . OLia
Ruth D. Oliva, Chairwoman 120SM5
Approved for Filing
f
APPEALS BOARD MEMBERS �rjf sour _ Mailing Address:
Ruth D.Oliva,Chairwomany, �'p�d Southold Town Hall
Gerard P.Goehringer 53095 Main Road•P.O.Box 1179
Southold,NY 11971-0959
James Dinizio,Jr.
G Q Office Location:
Michael A.Simon '�`O ,^�aa�� Town Annex/First Floor,North Fork Bank
Leslie Kanes Weisman �'Ycout r( 54375 Main Road(at Youngs Avenue)
Southold,NY 11971
http://southoIdtown.nonhfork.net
ZONING BOARD OF APPEALS RECEIVED
$ + _,� _ � i�., �q
TOWN OF SOUTHOLD ✓�•
Tel.(631)765-1809•Fax(631)765-9064 OCT 9^2006,
FINDINGS, DELIBERATIONS AND DETERMINATION
MEETING OF SEPTEMBER 14, 2006 Southold Town Cleri
ZB File No. 5920—MARY BUTZ
Property Location: 2022 Hyatt Road,Southold CTM 50-1-21
SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this
application and determines that this review falls under the Type II category of the State's List of Actions,
Without an adverse effect on the environment if the project is implemented as planned.
PROPERTY FACTS/DESCRIPTION: The applicant's 33,119 square foot parcel has 25 feet along a•private
right-of--way(Horton's lane)which extends 174 feet from Hyatt Road,and is improved with 6-single-family,two-
stor ,dwelling with detached accessory garage,shown on the site survey map prepared by,Joseph A. Ingegno
dated August 31, 1999,revised"April 17,2006.
BASIS OF APPLICATION: Building Department's June 2, 2006 Notice of bisapproval, amended,June 8,
12006;citing Section'100M33 in its denial of an application`for a,building-permit,to'construct"a=proposed pergola
at less than the code-required 40 feet from the front lot line.
FINDINGS OF FACT
The Zoning Board of Appeals held a public hearing on-this application on August 31, 2006 at which time
written and oral evidence were presented. Based upon all testimony, documentation, personal Inspection of
the property,and other evidence,the Zoning Board finds the following facts to be true and relevant:
AREA VARIANCE RELIEF REQUESTED: The applicants originally requested proposed swimming pool as
shown on the August 11, 2005 site map prepared by Fairweather-Brown Design Associates at 12.5 feet from
the southerly front lot line, and 91+- feet from the top of the bluff. Rather than to submit a request for an
additional variance under Section 100-239.4 (concerning the required 100 ft. minimum from the top of the
bluff) the applicant, on August 25, 2005, filed an amended site map proposing the new pool greater than 100
feet from the top of the bluff(1079"). The pool is also shown at 12 feet from the southerly front lot line and
11'1"from the easterly side property line, at its closest points.
REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal
inspections,the Board makes the following findings:
1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a
detriment to nearby properties because the pergola will be located in a fairly isolated portion of the yard.
2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to
pursue, other than an area variance. There is limited area to locate the accessory pergola structure due to the
topography of the property(steep contour at the north side and varying contours on a small upland area of the
property), and the small upland area available for placement of an accessory structure.
r L, ,
Page 2—September 14,2006
ZB File No.5920—Mary Butz
CTM 50-1-21
3. Although the applicant states that the pergola will provide screening from the sun while enjoying the
swimming pool, the variance requested is substantial and is the maximum the Board will approve. It
represents nearly 30%reduction of the required front yard setback and
4. The difficulty has been self-created in that the variance is related to the choice of the owner in an area that
is restricted by the code for a minimum 40 ft. setback. The topography of the property creates limited
possibilities to locate an accessory pool,and the code requires a minimum of 100 feet from the top of the bluff.
5. No evidence has been submitted to suggest that a variance in this residential community will have an
adverse impact on the physical or environmental conditions in the neighborhood.
6. Grant of the requested relief is the maximum the Board would approve to enable the applicant to enjoy the
benefit of a pergola, while preserving and protecting the character of the neighborhood and the health, safety
and welfare of the community.
RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under
New York Town Law_ 267-B, motion was offered by Member Weisman, seconded by Member Goehringer,and
duly carried,to
GRANT-the,-variance as applied for, as shown on the elevation diagram prepared by North Fork
Permits date 5f6mpdd by 413AJune,13,2006,-and site survey-map prepared by Joseph-A. Ingegno -
dated August>311999,,revised April 17;2006.
This,action,does'not.pu# orize-or_condone an'y,cuiTe'nt or futufe;use,,setback or,oth6r,feature,of the subject.property,,that
Ma
te the`Zorilrig=Giide,otfie�;tlian such':iises;'setbacksarid other features as are'expressly addre§sed in.this action:
Ariy"'deviation`trom the variance giveii such'as extensions,or d'ertiolitions which are=norstiovan ori the`applicant's diagrams°-
or survey site maps,`are,not authorized under this application when involving`nonconformities under the zoning code. This
action does not authorize or condone any current or future use, setback or other feature of the subject property that may
violate the Zoning Code,other than such uses,'setbacks and other features as are expressly addressed in this action.
The Board reserves the right to substitute a similar design-that is de minimis in nature for an alteration that does not
increase the degree of nonconformity.
Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer and Weisman. (Members Simon and
Dinizio were absent.) This Resolution w u adopted (3-0).
Ruth D. Oliva, Chairwoman 10//'a/06
Approved for Filing
AGRICULTURAL DATA STATEMENT
ZONING BOARD OF APPEALS
TOWN OF SOUTHOLD
WHEN TO USE THIS FORM: This form must be completed by the applicant for any special use
permit, site plan approval, use variance, area variance or subdivision approval on property within
an agricultural district OR within 500 feet of a farm operation located in an agricultural district.
All applications requiring an agricultural data statement must be referred to the Suffolk County
Department of Planning in accordance with Section 239m and 239n of the General Municipal
Law.
1. Name of Applicant: Pants View LLC
2. Address of Applicant:c/o Anthony Bonsignore, Manager;290 Park Avenue South 8th Floor NY NY 10003
3. Name of Land Owner (if other than Applicant):Same as Applicant
4. Address of Land Owner:Same as Applicant
5. Description of Proposed Project: See attached project description.
6. Location of Property: (road and Tax map
number) 2022 Hyatt Road, Southold, SCTM #1000-50-1-21
7. Is the parcel within 500 feet of a farm operation? { } Yes {x} No
8. Is this parcel actively farmed? { } Yes {x No
9. Name and addresses of any owner(s) of land within the agricultural district containing
active farm operations. Suffolk County Tax Lot numbers will be provided to you by the Zoning
Board Staff, it is your responsibility to obtain the current names and mailing addresses from the
Town Assessor's Office (765-1937) or from the Real Property Tax Office located in Riverhead.
NAME and ADDRESS
1.
2.
3.
4.
5.
6.
(Pleas use the back of this page if there are additional property owners)
Robert E. Herrmann 9 / 15 /21
Signatu f Applicant Date
Note:
1. The local Board will solicit comments from the owners of land identified above in order to
consider the effect of the proposed action on their farm operation. Solicitations will be made by
supplying a copy of this statement.
2. Comments returned to the local Board will be taken into consideration as part as the overall
review of this application.
3. Copies of the completed Agricultural Data Statement shall be sent by applicant to the property
owners identified above. The cost for mailing shall be paid by the Applicant at the time the
application is submitted for review.
�y
PROJECT DESCRIPTION
FOR
PANTS VIEW LLC
2022 HYATT ROAD
SOUTHOLD, NY
SCTM#1000-50-1-21
Remove existing 492 sf partially covered waterside deck(with pergola) from existing 1 and 2-
story single family dwelling, and construct 762 sf roofed-over, wrap-around deck, at least 11 feet
farther landward; reconstruct(in-place) approx. 226 sf portion of 2nd floor roof and 66 sf
balcony over proposed roofed-over deck; reconstruct(in-place) 459 sf 1-story portion of
dwelling; remove all existing accessory structures located seaward of top of bluff and/or within
Coastal Erosion Hazard Area, including Tx 7' spa, 137 sf deck, and 280 sf brick patio areas;
remove from landward side of house existing 56 sf 1 st floor front entry, 145 sf covered porch,
393 sf accessory garage, 226 sf pergola, and 1,454 sf brick patio around pool; construct on
landward side of house a 274 sf grade-level masonry patio and 1,005 sf grade-level masonry pool
patio; remove existing fencing and install new 4'high pool-enclosure fencing; install new
pervious gravel driveway in place of existing driveway; remove existing conventional septic
system and install new UA sanitary system; and install stormwater drainage system, all as
depicted on the site plan prepared by Elizabeth Roberts Architects, dated August 2, 2021.
l
Short Environmental Assessment Form
Part I -Project Information
Instructions for Completing
Part 1—Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the
application for approval or funding,are subject to public review,and may be subject to further verification. Complete Part 1 based on
information currently available. If additional research or investigation would be needed to fully respond to any item,please answer as
thoroughly as possible based on current information.
Complete all items in Part 1.You may also provide any additional information which you believe will be needed by or useful to the
lead agency;attach additional pages as necessary to supplement any item.
Part 1—Project and Sponsor Information
Name of Action or Project:
Pants View LLC Renovation
Project Location(describe, and attach a location map).
2022 Hyatt Road,Southold,SCTM#1000-50-1-21;property is located off r.ow.on west side of Hyatt Road
Brief Description of Proposed Action:
Remove existing 492 sf partially covered waterside deck(with pergola)from existing 1 and 2-story single family dwelling,and construct 762 sf
roofed-over,wrap-around deck,at least 11 feet farther landward;reconstruct(in-place)approx.226 sf portion of 2nd floor roof and 66 sf balcony over
proposed roofed-over deck;reconstruct(in-place)459 sf 1-story portion of dwelling;remove all existing accessory structures located seaward of top of
bluff and/or within Coastal Erosion Hazard Area,including Tx 7'spa, 137 sf deck,and 280 sf brick patio areas; remove from landward side of house
existing 56 sf 1st floor front entry, 145 sf covered porch,393 sf accessory garage,226 sf pergola,and 1,454 sf brick patio around pool;construct on
landward side of house a 274 sf grade-level masonry patio and 1,005 sf grade-level masonry pool patio;remove existing fencing and install new 4'high
pool-enclosure fencing;install new pervious gravel driveway in place of existing driveway;remove existing conventional septic system and install new
I/A sanitary system,and install stormwater drainage system,all as depicted on the site plan prepared by Elizabeth Roberts Architects,dated August 2,
2021.
Name of Applicant or Sponsor: Telephone: 212-768-4500
Pants View LLC E-Mail:
Address:
c/o Anthony Bonsignore,Manager;290 Park Avenue South,8th Floor
City/PO: State: Zip Code:
New York NY 10003
1. Does the proposed action only involve the legislative adoption of a plan,local law,ordinance, NO YES
administrative rule,or regulation?
If Yes,attach a narrative description of the intent of the proposed action and the environmental resources that El
be affected in the municipality and proceed to Part 2. If no,continue to question 2.
2. Does the proposed action require a permit,approval or funding from any other government Agency? NO YES
If Yes,list agency(s)name and permit or approval:Town of Southold,Suffolk County Department of Health Services ❑ ❑✓
3. a.Total acreage of the site of the proposed action? 31,879 sf
b. Total acreage to be physically disturbed? <17,000 sf
c.Total acreage(project site and any contiguous properties)owned
or controlled by the applicant or pro)ect sponsor? 31,879 sf
4. Check all land uses that occur on,are adjoining or near the proposed action:
❑Urban ❑ Rural(non-agriculture) ❑ Industrial ❑ Commercial m Residential(suburban)
❑ Forest ❑ Agriculture m Aquatic ❑ Other(Specify):
❑Parkland
Page 1 of 3 SEAF 2019
5. Is the proposed action, NO YES N/A
a. A permitted use under the zoning regulations? ❑ ❑✓ ❑
b. Consistent with the adopted comprehensive plan? ❑ V ❑
6. Is the proposed action consistent with the predominant character of the existing built or natural landscape? NO YES
❑ V
7. Is the site of the proposed action located in,or does it adjoin,a state listed Critical Environmental Area? NO YES
If Yes, identify- F71 ❑
8. a. Will the proposed action result in a substantial increase in traffic above present levels? NO YES
❑ ❑
b. Are public transportation services available at or near the site of the proposed action? ❑ ❑
c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed ❑ ❑
action?
9. Does the proposed action meet or exceed the state energy code requirements? NO YES
If the proposed action will exceed requirements,describe design features and technologies:
❑ ❑✓
10. Will the proposed action connect to an existing public/private water supply? NO YES
If No,describe method for providing potable water:
A new well is proposed. F7 ❑
11. Will the proposed action connect to existing wastewater utilities? NO YES
If No,describe method for providing wastewater treatment:
A new I/A OWT septic system is proposed W1 ❑
12. a.Does the prolect site contain,or is it substantially contiguous to,a building,archaeological site,or district NO YES
which is listed on the National or State Register of Historic Places,or that has been determined by the 1:1Commissioner of the NYS Office of Parks,Recreation and Historic Preservation to be eligible for listing on the
State Register of Historic Places?
b.Is the project site,or any portion of it,located in or adjacent to an area designated as sensitive for ❑✓ ❑
archaeological sites on the NY State Historic Preservation Office(SHPO)archaeological site inventory?
13. a. Does any portion of the site of the proposed action,or lands adjoining the proposed action,contain NO YES
wetlands or other waterbodies regulated by a federal,state or local agency? ❑ ❑✓
b. Would the proposed action physically alter,or encroach into,any existing wetland or waterbody? ❑
If Yes,identify the wetland or waterbody and extent of alterations in square feet or acres:
Page 2 of 3
14 Identify the typical habitat types that occur on,or are likely to be found on the project site. Check all that apply:
mShoreltne ❑ Forest ❑Agricultural/grasslands ❑ Early mid-successional
®Wetland ❑ Urban m Suburban
15. Does the site of the proposed action contain any species of animal,or associated habitats, listed by the State or NO YES
Federal government as threatened or endangered?
16. Is the project site located in the 100-year flood plan? NO YES
❑ ❑✓
17. Will the proposed action create storm water discharge,either from point or non-point sources? NO YES
If Yes, � ❑
a. Will storm water discharges flow to adjacent properties? ❑ ❑
b. Will storm water discharges be directed to established conveyance systems(runoff and storm drains)? ❑ ❑
If Yes,briefly describe:
18. Does the proposed action include construction or other activities that would result in the impoundment of water NO YES
or other liquids(e.g.,retention pond,waste lagoon,dam)?
If Yes, explain the purpose and size of the impoundment: ❑ ❑
19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste NO YES
management facility?
If Yes,describe:
20.Has the site of the proposed action or an adjoining property been the subject of remediation(ongoing or NO YES
completed) for hazardous waste?
If Yes,describe:
Z ❑
I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF
MY KNOWLEDGE
Applicant/sponsor/name Robert E.Herrmann, En-Consultants Date: September 15,2021
Signature: Title-Coastal Management Specialist
PRINT FORM Page 3 of 3
i n
I.Quickly' i
Each''d'Vx r Slapaxi'a
Y' 86 mu vertically4
J- ,,-j0ifi6 Map 50
"t S,
NA
-3j, 7 7'
72Z74 '45'
3 143'
K3_
Baer TRK RG
48
25
5uffdk County Haq5tr-om map # 44 ash 7'
1, - +2,0001
11
Hon FW
J Por
TOW(/I Pt'! VIEW"'U1 G qG ;E
Site(ACCO55 Ula a
L 0 IM BURGUNDY CKA Do ImAy OR
114 1��l T
Pa
N1111
ZI
�� '1
Pk
CREEK
g/l
yo LONG
4§01 D
MOCKINGBIRD
Town
:Smo
-10110
48
25 I \ Y�V%`Y `Trt%•i, fl i�l ri y"r'➢�\ Q�
#
PP 1 —0 Southold " '—,'Fj
a zl-
FULUBIC IN-V �No;
° m \ Pel
M-
Dunes
144IS \��yo
Affl%�\T :A",
BI S
Park 1515, 0�k��`
a
x g
Tow .-k
0-111
Halt- 41
0,
N
SoutholaceCeraFoundf
HILL
11,4 v— Landin
D
QP
i
JASMINEHarper Pt
LA
Ell
JOCKEY CREEK 0. W7
IJA
Cera;CeEF c
`21
Solithold
c L Y
A
?'ti CA
PARD
Park So4qold Custer
1 9.51
1
Indian Muf Witute
7-7 AV PY SLEE
4
AC
r
W GLENN
A
/
Osprey's DOMInloril &A
VineyarasGREAT HOG
The
Tasting PS NECK I
RownUI hl
AP,
P E ONIC
Olt, 1411 L
I'Y
Winery
S I j I,
R
The en,
I 1 1 �" 'r� \�\�
71a
Board of Zoning Appeals APDlication
AUTHORIZATION
(Where the Applicant is not the Owner)
Anthony Bonsignore,Sole Manager
L Pants View TLC residing at 200 Park Ave. S,Fl 8th
(Print property owner's name) (Mailing Address)
New York,NY 10003 do hereby authorize
(Agent)
En-Consultants to apply for variance(s) on my behalf from the
Southold Zoning Board of Appeals.
(Owner's ature)
Anthony Bonsignore,Sole Manager Pants View LLC
(Print Owner's Name)
APPLICANT/OWNER
TRANSACTIONAL DISCLOSURE FORM
The Town of Southold's Code of Ethics prohibits conflicts of interest on the part of town officers and employees The purpose
of this form is to provide information which can alert the town of possible conflicts of interest and allow it to take whatever
action is necessary to avoid same.
YOUR NAME: Anthony Bonsignore,Sole Manager,Pants View LLC
(Last name,first name,middle initial,unless you are applying in the name of someone else or other entity,such as a
company.If so,indicate the other person's or company's name.)
TYPE OF APPLICATION: (Check all that apply)
Tax grievance Building Permit
Variance X Trustee Permit
Change of Zone Coastal Erosion
Approval of Plat Mooring
Other(activity) Planning
Do you personally(or through your company,spouse,sibling,parent,or child)have a relationship with any officer
or employee of the Town of Southold?"Relationship"includes by blood,marriage,or business interest."Business
interest" means a business,including a partnership,in which the town officer or employee has even a partial
ownership of(or employment by)a corporation in which the town officer or employee owns more than 5% of the
shares.
YES NO
If you answered"YES",complete the balance of this form and date and sign where indicated.
Name of person employed'by the Town of Southold
Title or position of that person
Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee.
Either check the appropriate line A)through D)and/or describe in the space provided.
The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply)
A)the owner of greater that 5%of the shares of the corporate stock of the applicant(when the applicant is a
corporation)
B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation)
C)an officer,director,partner,or employee of the applicant;or
D)the actual applicant
DESCRIPTION OF RELATIONSHIP
Submitted this day of 01D.
Signature
Print Name Anthony Bonsignore ager,Pants View LLC
AGENT/REPRESENTATIVE
TRANSACTIONAL DISCLOSURE FORM
The Town of Southold's Code of Ethics prohibits conflicts of interest on the nart of town officers and employees The purpose of this
form is to provide information which can alert the town of possible conflicts of interest and allow it to take whatever action is
necessary to avoid same.
YOUR NAME : Herrmann, Robert E.
(Last name,first name,middle initial,unless you are applying in the name of someone else or other entity,such as a
company.If so,indicate the other person's or company's name.)
TYPE OF APPLICATION: (Check all that apply)
Tax grievance Building Permit
Variance XXX Trustee Permit
Change of Zone Coastal Erosion
Approval of Plat Mooring
Other(activity) Planning
Do you personally(or through your company,spouse,sibling,parent,or child)have a relationship with any officer or
employee of the Town of Southold? "Relationship"includes by blood,marriage,or business interest."Business interest"
means a business,including a partnership,in which the town officer or employee has even a partial ownership of(or
employment by)a corporation in which the town officer or employee owns more than 5%of the shares.
YES NO X
If you answered"YES",complete the balance of this form and date and sign where indicated.
Name of person employed by the Town of Southold
Title or position of that person
Describe the relationship between yourself(the applicant/agent/representative)and the town officer or employee.
Either check the appropriate line A)through D)and/or describe in the space provided.
The town officer or employee or his or her spouse,sibling,parent,or child is(check all that apply)=
A)the owner of greater that 5%of the shares of the corporate stock of the applicant(when the applicant is a
corporation)
B)the legal or beneficial owner of any interest in a non-corporate entity(when the applicant is not a corporation)
C)an officer,director,partner,or employee of the applicant;or
ID)the actual applicant
DESCRIPTION OF RELATIONSHIP
Submitted this 15th day of September 20 21
Signature
Print Name Robert E. Herrmann
r
Town of Southold
LWRP CONSISTENCY ASSESSMENT FORM
A. INSTRUCTIONS
1. All applicants for permits* including Town of Southold agencies, shall complete this CCAF for
proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This
assessment is intended to supplement other information used by a Town of Southold agency in
making a determination of consistency. *Except minor exempt actions including Building Permits
and other ministerial permits not located within the Coastal Erosion Hazard Area.
2. Before answering the questions in Section C, the preparer of this form should review the exempt
minor action list, policies and explanations of each policy contained in the Town of Southold Local
Waterfront Revitalization Program. A proposed action will be evaluated as to its si nificant
beneficial and adverse effects upon the coastal area (which includes all of Southold Town).
If any question in Section C on this form is answered "yes" or "no", then the proposed action will
affect the achievement of the LWRP policy standards and conditions contained in the consistency
review law. Thus, each answer must be explained in detail, listing both supporting and non-
supporting facts. If an action cannot be certified as consistent with the LWRP policy standards and
conditions, it shall not be undertaken.
A copy of the LWRP is available in the following places: online at the Town of Southold's website
(southo ldtown.northfork.net), the Board of Trustees Office, the Planning Department, all local
libraries and the Town Clerk's office.
B. DESCRIPTION OF SITE AND PROPOSED ACTION
SCTM# 50 - 1 - 21
PROJECT NAME Pants View LLC
The Application has been submitted to (check appropriate response):
Town Board ❑ Planning Board❑ Building Dept. ® Board of Trustees ❑
Category of Town of Southold agency action (check appropriate response):
(a) Action undertaken directly by Town agency (e.g. capital ❑
construction, planning activity, agency regulation, land transaction)
(b) Financial assistance (e.g. grant, loan, subsidy) ❑
(c) Permit, approval, license, certification:
Nature and extent of action:
Remove existing 492 sf partially covered waterside deck(with pergola)from existing 1 and 2-story single family dwelling,and
construct 762 sf roofed-over,wrap-around deck,at least 11 feet farther landward;reconstruct(in-place)approx.226 sf portion of 2nd
floor roof and 66 sf balcony over proposed roofed-over deck;reconstruct(in-place)459 sf 1-story portion of dwelling;remove all
existing accessory structures located seaward of top of bluff and/or within Coastal Erosion Hazard Area,including 7'x 7'spa, 137 sf
deck,and 280 sf brick patio areas; remove from landward side of house existing 56 sf 1st floor front entry, 145 sf covered porch,393 sf
accessory garage,226 sf pergola,and 1,454 sf brick patio around pool;construct on landward side of house a 274 sf grade-level
masonry patio and 1,005 sf grade-level masonry pool patio;remove existing fencing and install new 4'high pool-enclosure fencing;
install new pervious gravel driveway in place of existing driveway;remove existing conventional septic system and install new FA
sanitary system;and install stormwater drainage system,all as depicted on the site plan prepared by Elizabeth Roberts Architects,dated
August 2,2021.
Location of action: 2022 Hyatt Road,Southold
Site acreage: 31,879 sf
Present land use: Residential,one and two-story,single family dwelling
Present zoning classification: R-40
2. If an application for the proposed action has been filed with the Town of Southold agency, the following
information shall be provided:
(a) Name of applicant: Pants view LLC
(b) Mailing address: c/o Anthony Bonsignore,Manager
200 Park Avenue S,8th Floor,New York,NY 10003
(c) Telephone number: Area Code 212-768-4500
(d) Application number, if any:
Will the action be directly undertaken, require funding, or approval by a state or federal agency?
Yes ® No ❑ If yes, which state or federal agency? NYSDEC
C. Evaluate the project to the following policies by analyzing how the project will further support or not
support the policies. Provide all proposed Best Management Practices that will further each policy.
Incomplete answers will require that the form be returned for completion.
DEVELOPED COAST POLICY
Policy 1. Foster a pattern of development in the Town of Southold that enhances community character,
preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location, and
minimizes adverse effects of development. See LWRP Section III- Policies; Page 2 for evaluation
criteria.
Yes1:1 No VN Not Applicable
Attach additional sheets if necessary
Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See LWRP
Section III- Policies Pages 3 through 6 for evaluation criteria
❑ Yes ❑ No ® Not Applicable
Attach additional sheets if necessary
Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See
LWRP Section III - Policies Pages 6 through 7 for evaluation criteria
❑ Yes ❑ No ® Not Applicable
Attach additional sheets if necessary
NATURAL COAST POLICIES
Policy 4. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP
Section III- Policies Pages 8 through 16 for evaluation criteria
® Yes ❑ No ❑ Not Applicable
-SEE ATTACHED ADDENDUM-
Attach additional sheets if necessary
Policy 5. Protect and improve water quality and supply in the Town of Southold. See LWRP Section III
- Policies Pages 16 through 21 for evaluation criteria
® Yes ❑ No ❑ Not Applicable
A stormwater drainage system is proposed to capture and recharge roof runoff;and the existing conventional septic system will be
replaced with a new UA sanitary system located at least 85 fewet from the top of bluff and 250 feet from the surface waters of Long
Island Sound,thus protecting and providing a potential improvement to the quality of groundwater and surface waters,consistent with
Policy 5.
Attach additional sheets if necessary
Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including
Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section III - Policies; Pages 22
through 32 for evaluation criteria.
®Yes ❑ No ❑ Not Applicable
LWRP CONSISTENCY ASSESSMENT FORM ADDENDUM FOR
PANTS VIEW LLC
2022 HYATT ROAD
SOUTHOLD,NY
SCTM#1000-50-1-21
Policy 4:
The existing bluff, the property's natural protective feature, appears to be stable and well
vegetated, and the top of the bluff seaward of the dwelling structure is partially retained by a
legally preexisting retaining wall (see Town Coastal Erosion Management Permit No. 5519).
Nevetheless, the project design will achieve 1) an 11-foot or more than 1,000% increase in bluff
setback to the primary dwelling structure, relative to the legally preexisting partially covered
deck attached to the seaward side of the dwelling having a zero-foot bluff setback; and 2) a 23-
foot increase in the property's overall bluff setback through permanent removal of the legally
existing spa having a bluff setback of negative 12 (-12) feet. And as a result of the removal of
various structures located partially or entirely within the Coastal Erosion Hazard Area, including
the partially covered deck attached to the seaward side of the existing dwelling and the accessory
deck, spa, and brick patios, the project design will result in the permanent elimination of
approximately 340 sf and thus all structural surface areas situated within the Coastal Erosion
Hazard Area. The project will therefore result in a decreased risk of flood and erosion damage
and will be consistent with Policy 4.
Policy 6:
Consistent with Policy 6, the proposed project design and incorporated mitigation measures are
intended to minimize or eliminate any potential adverse impacts on the environmental conditions
of the property and to protect and restore the quality and function of the Town's ecosystems
through beneficial impacts on treatment of septic waste; stormwater runoff control and recharge;
and the environmental quality of groundwater, adjacent surface waters, and the adjacent bluff,
shoreline, and wetland ecosystem:
1) The existing bluff, the property's natural protective feature, appears to be stable and well
vegetated, and the top of the bluff seaward of the dwelling structure is partially retained
by a legally preexisting retaining wall (see Town Coastal Erosion Management Permit
No. 5519). Nevetheless, the project design will achieve 1) an 11-foot or more than
1,000% increase in bluff setback to the primary dwelling structure, relative to the legally
preexisting attached covered deck having a zero-foot bluff setback; and 2) a 23-foot
increase in the property's overall bluff setback through permanent removal of the legally
existing spa having a bluff setback of negative 12 (-12) feet.
2) The project design will result in a 737 sf or 19% decrease in existing lot coverage, thus
reducing the existing nonconforming lot coverage from 26.1 to 21.1 percent, as a result of
the proposed decreases in the footprint of the habitable dwelling structure and attached
decks/porches; and removal of the accessory garage, pergola, and spa.
1 I Page
3) The project design will result in the permanent elimination of approximately 340 sf and
thus all structural surface areas situated within the Coastal Erosion Hazard Area, as a
result of the proposed removal of the existing 492 sf attached covered deck, 105 sf brick
patio, 49 sf spa and associated 137 sf accessory deck, all located partially or entirely
within the Coastal Erosion Hazard Area.
4) The existing conventional septic system will be removed and replaced with a low-
nitrogen, I/A sanitary system consisting of an I/A OWTS located at least 85 feet from the
top of bluff and leaching pools located more than 100 feet from the top of bluff and 250
feet from the surface waters of Long Island Sound. Unlike conventional systems that are
not designed or equipped to treat nutrients such as nitrogen, UA systems are designed to
significantly reduce nitrogen loading into the groundwater and ultimately surface waters.
5) A proposed stormwater drainage system is designed to capture and recharge roof runoff
from the renovated dwelling; surface runoff from the driveway; and backwash from the
existing swimming pool .
6) A project limiting fence will be installed to contain site disturbance and potential surface
runoff during construction.
2 1 P a g e
-SEE ATTACHED ADDENDUM-
Attach additional sheets if necessary
Policy 7. Protect and improve air quality in the Town of Southold. See LWRP Section III - Policies
Pages 32 through 34 for evaluation criteria.
❑ Yes [:] No® Not Applicable
Attach additional sheets if necessary
Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous
substances and wastes. See LWRP Section III - Policies; Pages 34 through 38 for evaluation criteria.
❑ Yes ❑ No ® Not Applicable
PUBLIC COAST POLICIES
Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public
resources of the Town of Southold. See LWRP Section III - Policies; Pages 38 through 46 for evaluation
criteria.
❑ Yes ❑ No® Not Applicable
Attach additional sheets if necessary
WORKING COAST POLICIES
Policy 10. Protect Southold's water-dependent uses and promote siting of new water-dependent uses in
suitable locations. See LWRP Section III - Policies; Pages 47 through 56 for evaluation criteria.
❑ Yes ❑ No ® Not Applicable
Attach additional sheets if necessary
Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic Estuary
and Town waters. See LWRP Section III - Policies; Pages 57 through 62 for evaluation criteria.
❑ Yes ❑ No ® Not Applicable
Attach additional sheets if necessary
Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section III — Policies; Pages 62
through 65 for evaluation criteria.
❑ Yes ❑ No ® Not Applicable
Attach additional sheets if necessary
Policy 13. Promote appropriate use and development of energy and mineral resources. See LWRP
Section III - Policies; Pages 65 through 68 for evaluation criteria.
❑ Yes ❑ No ® Not Applicable
PREPARED BY TITLECoastal Management Specialist DATESept. 15,2021
Robert E. e
Amended on 811105
t
PANTS VIEW LLC,2022 HYATT ROAD,SOUTHOLD
4
r
AA
L1
t
2022 Hyatt �•
t
Google Earth 4JA
r4
Figure 1. .Aerial view of subject properly/dwelling and surrounding developed shoreline in April 2021. Image by Google Earth.
IMFx `f1
�L,, �. `► .� ply_`. �- '� *j, Y '
Figure 2. Looking;east front beach along Long Islan l Sound toward blu f an l e_ristinl, dwellin„to be renovated.
r
PANTS VIEW LLC,2022 HYATT ROAD,SOUTHOLD
:e
``z►-:v;'ay 4
1.
Figure 3. Looking east at existing dwelling to be renovated and at the existing retaining wall situated at the top of bluff,
upon which sits the existing spa and accessory deck to be removed.
5
AZO
'w
m
A
• v..A
4
'-
.�
d v
x
Figure 4. Looking west toward Long Island Sound,over existing spa,accessory deck,and brick patio to be removed.
00- a
1 \
ids
vow
h.
yµ6 qyy a
_ �r > >Y r ltli�t�►}may.
r
t\ �
IIII
' I I I / 'l l l / / / ' I • / • I / + // l
'•• �� ��. -- Rte ,.„
,�. R �� •1 ; � 1a.bf. a J✓•, , �� t'' � ��,Y, r
_ - a
` � 1
J
1
Ir
EXISTING CHIMNEY PROJECT
CAP TO BE REPLACED
4=?
-- -
TO ROOF __ SOUTHOLD
EXISTING BOILER
FLU TOBE
RELOCATED RESIDENCE
RELOCA
y
PANITSVIEWLLC
2022 HYATT RD
SOUTHOLD,NY 11971
SCTM#1000-50-1-21
EXISTING ASPHALT
SHINGLES TO BE ARCHITECT
REMOVED,TYP
EXISTING ROOF OVER
BEDR
TTICFLOOR _- 1' '�„ _ MODIFFIIED TO BE
A
E R b
EXISTING WIND OWS ELIZABETH ROBERTS ARCHITECTS
TO BE REMOVED,TYP niyT�TY� i�-_+�1 ��T'T9�'r-� i=-TSI; pvveeaeaeaeaq 1687TH STREET 3C
I'1 Y Y Y141 Ir--=----=--T/ BROOKLYN,NY 11215
I I I EXISTING SLIDING
U D N c�1/ } I/ 7185046488
�txnxy�1/ GLASS DOORS TO BE
EXISTING ROOF OVER II I I ;Ir_x�•-•II I 11 Fy_�9 IFv�l I,/ REMOVED
1 ih=_=__I L_�_JIL�+�JII Ik_____lii i -____________
DINING ROOM AND �RRM1rv,T•�n= aaa aamRm
KITCHEN TO BE MODIFIED 1 II u'n nunnn iu In li uul ul lil uu4li Vln nnnni llounil
in 11'unnnnll I nmlr 114 bnnunnlil4ll"' EXISTING BALCONY EXISTING ROOF OVER
II IF 1111 1 n
ILLLLLLLLLL It III(ILII III 41111411 II 1 I 14111111
44 II 111 II L Iyl4 ilyyl Inllyl�i I i unn TO BE REPLACED :' `.� 1STORY EXTENSION
EXISTING PERGOLA -_-- III II IfIIIIRITITIfn'II MY 111111
1111111111111111111111111111 II II II I pl 11 l II II IIII 1111111111111111111111 '' �``. TO BE REMOVED
TO BE DEMOLISHED 1111unnn"1 un11u 11 lun 111"11"1111111"1"1"1"11111 I _________________________,,;___________________________________________________
m 111111111111111111111111 I I1 II11111III 1111111111II ii ii 111111
SECOND FLOOR ____ _ _��.
_ _ _ _ fir- - __a___ _____________.i ____ -________ __
+e'a1n' ---- -
- ------------------------------------------------------------- -- - RA
-
�_____ ______L ______________________________ __________________________________________ ______ r 1 I EXISTING ROOF OVER
___ _____________________
r
11__________ _ ___ ___ _____ J I I'1 IIII ,1 I I I Iii i i Ili I EXISTING ENTRYWAY
u u _____-'r- _ T =_-
r��_�_�_������_��_�����_����� __,i �+I-vl'T�1 i I i111A A Ari iilA A A n ; AND PORCH TO BE
1i�Y�Y'•Yip 1h Y~Y^Yip 11iY•`Y^y111 1 I r===Tr =-T lit-ri-�11 i �r vli; 1 ;�l iir-1�� I rl'Y Y Yj I ; 14k�..WI'I 14k.r.xJ�i i4Y.�xn'" 1 REMOVED
l i 'I i i i lil Iii 1 1 1 III II;1 1 1 ill I I IIF n?11 Ij5_n?I1 I; I III ; I I III 111 111 ;
IF 1 1 I ;I I j1 I'I Ijl ;II
11 1 I Ixx xxl lx xjll I
•H EXISTING WOOD DECK II ;;II 111 i i 1 pl I IIr Y]II Ilr_Y]ll IIX_v_y11 I I;I 1 I i I;I I III III II i ii I I 1 "I ;11
n TO BE DEMOLISHED i ii A A App i�rAv�vAuii iiuA„J.,,A,ii i �i—_=_,11 1h__=_,11 lh____/I 1 111 t 1111 1 lu p 11 �A..AyA 1 I I Il I ih 1i1
m II Ik M=w=.111 III Ir_____� IIII III III III IIII 1'I II I III ill SII I i4____ i II�____�II EXISTING BAY
I II III III
IF III IIII III___ull IIL__ '11 III IIII Ili-- Yw'I 1 ;II III III I �I I j I�--- I•-------'1-r——� I I
_JU II�___�I1I _ I WINDOW TO BE
iii 111 Ili ISI iii Ili --�J�-- � iii i i i III i Iii Y Ili i
IJ I I REMOVED
_
IIF'rlxllll 111111 ilnnuliilnnil ll' u11111111in 111 �i1 it lln nll i� iil� _ j1 II ;i i�____
LA un1"ili11i 11111 ill
I I 111111 0 11 II II n 11 n n 11 11 IF 1111 n 11''1111 IT IIe _I;;LL_____11 _n= n 1 p�1ppi,, I 'I°n 1 I 1 1
n n n n n n 11 11 0 11 11 11 1 n o n n o p n n n u n n n u u I I 1' II - --- ii ii� �i��db�i'H E 1^ I i 1�1 EXISTING COVERED
I in
4 n 11 11 11 11 4 II Il 11 n n 111 I l n I ---------_--_-___-- II IIII II II I IIII;II I I I
I 11 0 11 11 11 n n II II It 0 11 Ill n 11 11 11 11 11 11 11 II I I n l l I l d -----------
e I Illy 11 I I l�;i ; PORCH TO BE
TILL 1111 IIn 1111 y1y111111 Ii�Oiiyiy llILLYy Ill loll II ii it 11111111111111111111 ii iil Inlni II 1 DEMOLISHED
uy �ILuu u uuuuuuuuuuuuu_ II I
I
FIRST FLOOR 1_________________ ________ L 1 11 J
Y +/_0,-0' _e �ee�e=_�=.��__�_�==_ae�__-_ten__== �k===7t=.=d I� - -- ___- - - - - ---'"-__...,_..2_�_. I�6ey;6eve6J>�J1 T i
I s=�I I I I
i 6��_y �eesevaell 1 F�EXISTING NTOI-STORY
BEvr,�r-vr :r.rr.xr xr�v\xrr�•,>„,.r .r. .x �vavee� I I - •; r I S r______________________________________
r ,>'-li s�111.veseedd DEMOLISHED TO TO
EXISTING FOUNDATIONS
i
�1 SOUTH ELEVATION-DEMOLITION
NEW CHIMNEY CAP
RECEIVED
V T O ROOF
+2T-9"
NEW LOCATION OF
BOILER FLUE
EP 2 2 2021
4 "
NEW CEDAR ROOF - -
ZONING BOARD OF APPEALS
SHINGLES,TYP - y Y> NEW ROOF OVER
� ATTIC
BEDROOM
FLOR
+18'-a 1 11•O --- --
NEW SCONCE,SPEC
TBD �\ I
i
m ! 01
qISSUE
NEW FLUE FOR NEW
NEWBALCONYAND WOODSTOVE NO DATE DESCRIPTION
RAILING 01 08/022021 DOB FILING
4
NEW ROOF OVER
SECOND FLOOR
NEW ROOF -""„ -'V ` _ - _ 1-STORY EXTENSION --- - - -
/L
_ ____ _ __ - _ •_ ___ " - . - - ___ " - __ ____ __ _ _______ _ _ __ _ ____ _ ___ _ _ _ __ __ _ _ ___ _ -__ __ _____ ._
NEW 6X8 WOOD POSTS FOR " __ _
NEW DECK AND ROOF,SEE
BUILDING SECTION FOR
STRUCTURAL INFO
.A
NEW WOOD DECKAND RAILING — TITLE
n
101
SPACING,TYP EXISTING +
tt
FIRST FLOOR _. § PROPOSED SOUTH
+/_0•.0• ELEVATION
I SEALANDSIGNATURE DATE 08/022021
FPROJECT#'1922_HYATT RD
WOOD LATTICE BETWEEN
COLUMNS
DRAWING BY CM
SOUTH ELEVATION-PROPOSED
CHECK BY AV
114
DRAWING NO
A-200.00
rEHso'_ssncnxcr
uxoEH IHE OHEcnon�n
Tmsoxnwl1G
lx}xrwnIxurr lrsaoxTHls
THEKTE CMC rtECTEHnLL usl%TOHIswEx liEa THESEnLu14THI
T•rOLLQwEoeTnlSmrn SlGxnT x rx T }iT xwTOx
�5
EXISTING CHIMNEY PROJECT
CAP TO BE REPLACED 4_f
TO ROOF SOUTHOLD
1
RESIDENCE
IIS-EXISTING BOILER
I i FLUE TO BE
RELOCATED
PANTS VIEW LLC
I I 2022 HYATT RD
q I I SOUTHOLD,NY 11971
------ --- SCTM#1000,50-1-21
EXISTING ROOF OVER I k xVn {I '
I Ilaae.°.a:y I I
BEDROOM TO BE
MODIFIED I iii Ili I, i ARCHITECT
d 1
A e-a LOO# - — - -- - - —-- - - - - --- - - -f_=_---_--_- -_-_-- - -_-_-_ - ---- E R V
m mm NY JiVlninnWunWuuWunWnllWunnWu RullWnnili :IIIIrIiIIFlIL_�t__T_'_'_'_tLr__HJ_IAIi,iIIiI_iIIII_rIiIIYlILi_te__T_+_"_rt___l!JI_iIIli'II r�II,IIL�IIirIIi='��;I iINIII��hjIIL.__1"___-„_--__�.IiI�I
ELIZABETH R
OBERT
S
ARCHITECTS
iPW-;n1lNGWINDOWS 718504
l- 168THSTREET 3C
illyBROOKLYN,NY17215YYVIi iIti 6488EXISTING BALCO __ EXIS{ BE REMOVED,TYPTOTI
TO BE REPLACED UON
EXISTING ROOF OVER
W EXISTINGOOFOVER 1-STORY EXTENSION
EXISTING ENTRYWAY -
.I TO BE REMOVED
if if if if if if if iif° R� - ----------- ��
AND POREMOVEO Iln nnn nnnnnnll
I.L SECOND FLOOR _ _ _ _ __ _ _ -�yyyy"y.,wJ _ _ _ /._'�^�� _ _ _
+9'•712° -- - `
_ a=-__-_~____________________
��.' .Y_______--__
�___________y Ir-----I r=--=� I
_r__—________T�_—________yR�_____T__�}�__r______� ; I III III III �
1 I I I I I I I I I I CCaaa '�I 111 III III I
I I I aaad I I I I I I ___ 1 111 14 III I 1
I �___S I I _!I I -i 11. I fl"•-^ , I III ISI ISI I I
I IIS l{—?ilIrti 1 II 1�I�; 11 I 111 111 I
I 11IX X 1 j l IIiX'�I ,I I I II I , II II II II EXITING 1-STORY
I II[Y SII II I II I I II I IIS 1 IIL____JII IIL____JII I� BE
-
I II,___�I Ik=y� I 11 I I II I III i 11 I�_____7II Ilr_____TII DEMOLISHED
TOT
� h, ,p � i Ip �I 1 it III I F y I 4 lil 14 I � DEMOLIBHEO T0T0
III III I I I II I IILa�r I III i4 II 111
Na-___s1 I f lid—I I I l i 11 I 1 I 14 dl 1q I EXISTING
I III TAT I III III I III I
EXISTING COVERED I =___- FOUNDATIONS
I q l �, III II III III I ,
PORCH BE ,�'Iililililililililililinil�, I�'lililililililililij�jiin, I I I`I nunnl ! oli+1 11L__-_J4 ilL____JI!
mm
DEMOLISHED nnn nnnllnnnllnn unllnnnn nu nn I I � II,I I ullunll idb��{I�o�1111 '-�==1i=-------- I
I I I 1111'.11
I II I I I 1I I
in ii ii ii ii ii ii ii ii iiriiiiil I11111111111 ii if ii iiiiniiniiiil adddd"nail I
n„IIayy nnl i i
h FIRO-0FLOOR _ __— _ - _ -
I beOve�'i Peg-- ----___--_____
I ni—7777-.a,�_1 I �
, "',,rcco i_ I I I _________________________________________ I
I 6�veee�d 161�d I F0000000000v0000u� I
1,-a:.,'-`a',`.vil':�':�--af, II„::`.- fi�•i I I II 1
Sh
��-a , -�;iF,S,iveeevee=Snp1i I
_�°_=:.` 1 I aaeeoe=aiae�mnou=mvn
EAST ELEVATION-DEMOLITION
NEW CHIMNEY CAP
iL TO.ROOF _ _ --- -_-_ --_ - _—_- -
NEW BOILER FLUE
LOCATION
PH
JI:
NEWROOFOVER
BEDROOM NEW CEDAR SHINGLES.
' •�1 Iry 'L .l 13 TYP
ATTICFL�12OOR _
r1 NEW SHUTTERS
}m ® II i 4 FABRICATE TO MATCH
EXISTING
II l_-� LI
r--; ;r--INEW CASING FOR ISSUE
I. I RELOCATED BOILER
( I FLUE REVIEW WITH NO DATE DESCRIPTION
NEW BALCONY ANO
RAILING -i -� - I--' I -- ARCHITECT ONSITE 01-_ _ 08/022021 DOB FILING
q
i'F_. u�l __ - NEW FLUE FOR NEW
.6.
/L SECOND FLOOR -__ _ _ _ - __- - -__-_ - _ - ".:.'„.,:.�V�__ _ _ _
, � , WOODSTOVE
__
+9'-712' _.-n•_�.... -.
_L'r
_
NEW 6%6 WOOD POSTS FOR .,� -�.•,+ � _ _
_J ,�'L nl-- 17i1 NEW ROOF OVER
NEW DECK AND ROOF,SEE ISTORY EXTENSION
BUILDING SECTION FOR
STRUCTURAL INFO j
tit
NEW WOOD DECKLIRAILINGNEW SCONCES,SPEC TITLE
-.1 ❑" -�
RANG i b TBD,TYP
<" = EXISTING +
SPACING,NG,TYP
i
PROPOSED EAST
FIRSTFLOOR m ! ___ _____ ELEVATION
NEWWOODLATTICE
BETWEEN COLUMNS
BEAL AND SIGNATURE DATE 06/022021
NEW ENTRY PROJECT 1922 HYATT RD
_ 1 DRAWING BY CM
1 _
EAST ELEVATION-PROPOSED CHECK BY AV
2 v4°=1'-0” --HECK--- ---- - --
`DRAWING NO
A-201.00
P -unx�a. %.WA
ueexssoim+Eoix�e exlxu.wcwm IersnniL
+' rro Anon nLrElreoervaL-lrcwsmenslcw� nNnnwa
I
1
PROJECT
EXISTING CHIMNEY
-4 4-T, 77CAP TO BE PLACED
T
/b O SOUTHOLD
OOF R -_ _ _ — _ - - - _- _
EXISTING BOILER
FLUE TO HE
RESIDENCE
REELOCALOCATEEDD
1
I I
PANTS VIEW LLC
Y i i 2022 HYATT RD
---�I SOUTHOLD,NY 11971
I 1 jel �I i i�I SCTM 0100D.5&-l-21e eF-__J I
ARCHITECT
h
ATC F2LO°OR IIIIi IiI�IiItIILIIIC_�III1 ItI1II�i�4I'lL;IL�1_T1I�1_TII_T�a_I l�JJIt��I1i1 IIII1l1l II`I1L__j��i�IIIIlI1I ��IiIIIIIL J1IVI''V\I1I11A1III11I1IIII1IIII�L1I1I__�1L_fT�_�_^;�_;__.yA�IlII°n1iiI'IiI1l1//1////1//II11I1lL_JIiitI�ItlII I�IIIIIIIIIIIIIL J111i((111111lIIA114111lII1111nIII
..l-:d_..�:J�n1j11i11I111111I//////1//Sj11I=1L JiIIIIt1II'I1I
m_
E R V
ELIZABETH R
OB
ERCT
S
ARCHITECTS
1687TH STREET 31
Erm],
BROOKLYN,NV 11215
7185045488
EXISTING WINDOW
EXISTINGROOFOVER EXISTING BOILER TO BE REMOVED,TYP
1-STORY EXTENSION FLUE HOUSING TO BE
UON
TO BE REMOVED RELOCATED _
___________________
_______—____—______—____—_—__—
____—__
_ _________SECO1N
+ 7 /2D __________________y __ _
_
I IL __jl P 61 11%HI 1;11 : i ----------P,�"v
EXISTING NTOBE I peonmmaaq paaama=aq ________ ilo m I
EXTENSION TO BE ; 1r,-===- / Ir,-===_�/ ,1 m m m oii # ti r EXISTING PERGOLA
DEMOLISHED ISTO n"irY Y Y�ili� Ii FY T Yy ie
4q1 l l 11/ 1111 e l Till i Ilk R W AI Dli l E � i i TO BE DEMOLISHED
EXISTING till '/ I11�cJ5a-m-.5oJ11 n�`
uAA A Ail/ 1111A
FOUNDATIONS--� n14�.-_,ii/ II4�.-+CJI/
nth
n�/ iil/ II11 il�/ EXISTING WOOD LISHEDDECK
111 qI i% Ilii Ijl% Oji iil j i� �TO BE DEMOLISHED
nI1L____JII/ n1LLL____JII/ _
\ ------
v
-----------------
------ \ IIL__________ , 1 M1�Tmmrmmn�r,rnTl
r,rmn„-mrm,rm,,,n
------ ------
FIR
---- 11111 III II II II 1111111111 II II II II II II 111111111111111111111111111011 1
� I I � IIID Iil tl 11 l�I�1�11111111 III 11 ' II II II II II II II II II II II II II II
1 1 1 I iilun nnnn11n11niihnn liiu iinnlul nnnnullu
I 1 I _—-- - — — _ ---- — =vvvvvv—ii1 noun I n 11 n 11 n n 11 n n 'n'!
—n 11 n n n nl
FIRST FLOOR I I I --1 f-`----1 l uu LuJLu-u 11auu�uuy�u l'a_�Auur luul�uup�u j
+/- _ _ __ _ _ i_ I - _I_ - - i i_ _ _ - _ - —_ _ ___— _I- _i i _ i C��aes,=e_neae,mee 3�eepLet=_�eNA
I r_
__________y______L_____a_______________________________�_________a___
I I
EXISTING PROPANE EXISTING GENERATOR EXISTING OUTDOOR EXISTING WINDOW TO EXISTING MECH EXISTING WINDOW TO
TANKS TO BE TO BE REMOVED SHOWER ENCLOSURE BE RELOCATED UNITS TO BE REMAIN
REMOVED TO REMAIN RELOCATED
NORTH ELEVATION-DEMOLITION
va^=no•
NEW CHIMNEY CAP
77-
/L +O ROOF •_
NEW LOCATION OF
BOILER FLUE
NEW CEDAR SHINGLES,
ATTIC FLOOR TYP
�I,'
NEWSHUTTERS _
FABRICATE TO MATCH
EXISTING
NEW CASING FOR
c? RELOCATED BOILER f ISSUE
- FLUE REVIEW WITH
ARCHITECT ONSITE NO DATE DESCRIPTION m
N
NEW ROOF OVER 1 1 1 - NEW ROOF Oi_ - 08/02/2021 DOB FILING
iSTORY EXTENSION j --
/L SECOND FLOOR
-------
-� NEW DECK AND ROOF,SEE
j BUILDING SECTION FOR
STRUCTURAL INFO
w TITLE
NEWWOOD DECKAND
' 1 RAILING
EXISTING +
SPACING,TYP
--- - -
---- -
PROPOSED NORTH
�- ---- -- - ---- - - -- � - --- - - -- - - -- - �- - I- - ---
® ® ® o ELEVATION
/L FIRST FLOOR _
• 0
RELOCATED EXISTING SEAL AND SIGNATURE DATE 08/022021
WINDOW
PROJECT tk 1922-HVATT RD
'DRAWING BY CM -- ---- - ---
�1 NORTH ELEVATION-PROPOSED CHECK BY AV
DRAWING NO
A-202.00
WTE P� Eu�M�
IlCEMSEmuICMrtECT TDKTEm NM1'l1Ew CMTMISC
x�MN NiFnEC iHEKTEM1MGTaCMrt SIG WL
M D�11EC11 1EDe'I 0N0NE0BYW5MER51Gwt a
r
PROJECT
CAPEX1TO BING CHIMNEY
4 � CAP TO BE REPLACED
iL
!OR __ SOUTHOLD
i
EXISTINGBOILERBE
RELOCATED E
; 1 RESIDENCE
FLUE A � l
1 l PANTS VIEW LLC
4
2022 HYATT RD
SOUTHOLD,NY 11971
SCTM#100050.1-21
D�1
1 111 _�jl EXISTING ROOF OV ER ARCHITECT
I -------5 BEDROOM TO BE
+8412"OR _._— _ _ _ _ _ _ _____ - _____ _ -__ ----------------------
ELIZABETH
_ MODIFIED_ _ _ _ -_
E R d
ELIZABETH ROBERTS ARCHITECTS
168 7TH EXISTING WINDOWS i 1i i111=fTi il/i 11 ll I,IIj-PT9'ilii i1 li iYililil Ii i1i i i 1 pi ili il BROOKLYN,NSTREET1215
TO BE REMOVED,TYP I l Ia4�.�- °. .{I1/I II I i10�..¢..¢..Fi1111 11 I 11!!.tt ri 111 ll 11� yl llCtttyl
718 504 5488
UON 1 i 11111 llil Il ii Ilii) 1 Iiil li ii l Ii1i it iMJ1`Mi ik='�`-Mi
I=iij_JI1/L_JI 1 L_.i 11L_l1J_J IIL_JI IIL=LLJ_.lI1/L_JI 1
m i IL=ia11r_ __TIIr-ll 1r-1111f-- --�11 I ILIlli _-�11/ III 1114
N - l i 1111 II1/1 ll 11 11111 11/i i1 i=i11n I1/r-i1 II II 14
it lal /1 1 II 1111 11 II Il IIIII /1 11 IlL ill III Ill
I 11111 Illll ll I 1111 III/1 II 11 11111 SII l I II____JII I,L____J,I gMgylAARs.
1 I 1x111 11 I II 11111 OI I1 11 11111 Ili II _______________ 11ililil 11 11111111111111
�L JaIIL___ JIIIL_J1 �L_J 111L------ ii 1111u u u u n n u EXISTING BALCONY
n n 1
lnxx n#nnnllnn
I pnnn nununnllp TO BE REPLACED
o uunnnunnnnnn
1lnnunnnnnnll
/L SECOND FLOOR I 1111111111411 ILLILL111111 1
+9'-712"
_n-___rt____.Yr�����r����n_____rt�___•1T����R�___T�___.T.___�����rt��� Tr _lr_���rt���_�r___
____y.__ JL____L_____LLJJLLL __JL___Jt____ ___ ____ ___ ____
EXISTING PERGOLA STT^______T
TO BE DEMOLISHED II f- -'-Ili-i-'-1 hII�T;f-I jfl -1 ilii i-i-'--lf-r-�-ii 11 lI�-^-^-111i I11x
1I F I i 111 1 h4 11 JJ LLyy.J11LLJJLLJJ I 1 i 1 1 Il I Y Y Y 1 Y^Y^'ij1 IYP1v^ l l
II II 1_�_t_yl�_t_�_yl nII��T�II IfTTTllli l II IIIII 1 IIII IIII 11111 II
11 I l 111 1 1 1 4
11 11 I ; l p111 1 1 111 1/ 1 ; l 1111 IIII 1j j11j Ii
EXISTING SLIDING I I I I 11 a 1 LJ_Ai.il LJIJyL_LJ11/ I ill i i IIII 1 1 l 111 l Ill I l ll 1 1
GLASS DOORS TO BEJII I A A AlI1 A A Alll
m
11 ll II IIII I III I Itil II l Y=V='AI Ik mo=w=ill Ip.=1..1_'±11111
REMOVED,TYP 1 1 II 1 l hlil 1 1I 1 1 I 1 111 II II II I III 111 II 1111
I I 1111 II 1111 III III II it
Ip I
11 11 r-f-f-11r-$-t-y ph1 1 n 1N r�+_t_11�_}-t-11 it t ii 1j11
I I I I I 11 111 ;111 1
I I III 1 ; OIIL___ J IL_LL__JII/ I l 1 Ill I II 11 Ill
I I I I 11 I I I 1 I __ 11 I 111 I I IIII III III III III I I 111 I
IiiI 1
FIRST FLOOR II II _______________ II II vv=eee�=___
'_ 16seL1 _see=e��= =ee==__L____------ �eeme _ e ae�_=aid_=nese=snev6==vee=�e==�36Qeu=ase
+!-0'-0 _ EXISTING WOOD DECK ------------------------ ______ _
_r_ ___�______T______�P___________ _-_-_______-______________
TO BE DEMOLISHED�+ Ili 11l pi ili ii L-
-11i ui iii ip L_
= III III 01 III Ip ``�`L-1
EXISTING SLIDING li ili ip
DOORS TO BE
REPLACED n
/L BASEMENT FLOOR 6mveeve'd�vevee�d
�1 WEST ELEVATION-DEMOLITION
NEW CHIMNEY CAP
-/�
10 ROOF
NEW BOILER FLUE
LOCATION
4 ,
' NEW CEDAR
SHINGLES,TYP
i� ATTIC FLOOR
+18'4 12'
NEW SHUTTERS
FABRICATE TO MATCH
EXISTING
I
NEW CASING FOR ; € ISSUE
RELOCATED BOILER �i j
FLUE REVIEW WITH I l NO DATE DESCRIPTION
ARCHITECT ONSITE - NEW BALCONY AND 01 _ 08/022021 DOB FILING
-. q RAILING
SECOND FLOOR
+9'-
NEW 6X6 WOOD
NEW WOOD DECKAND POSTS FOR NEW
DECK AND ROOF,SEE TITLE
n RAILING BUILDING SECTION
4"� 105 104 103 10 FORSTRUCTURALEXISTING +
SPACING,TY
PROPOSED WEST
rLFIRST FLGDR -- E L E VAT I O N
NEW WOOD LATTICE
BETWEEN COLUMNS
SEAL AND SIGNATURE DATE 08/02/2021
-'1 PROJECT#1922 HYATTRD
DRAWING BY CM
� BA-7SEMENT FLOOR
-T "
CHECK BY AV
WEST ELEVATION-PROPOSED DRAWING NO
/4•=,'-D• A-203.00
�wnYEumliExiN1E
E�
LGxnNn,wO�NEE diE OF SUCN•LTFAnirox
SCTM#
j DDD - �D - ) -? TOWN OF SOUTHOLD PROPERTY RECORD CARD I I-)o(q
OWNER STREET 0 ,22 VILLAGE DIST. SUB LuT
e L L C—
IJ A
�v 4 � � ACR. REMARKS
S C it L k TYPE OF BLD.
VK OLS PROP. CLASS
LAND IMP. TOTAL DATE q C7 �{� �J � "i _ {�lt�-Z '�77 oy)f 3 '/ te&1 -�Z,g5l (200
3? Db q (o DD 121'900
FRONTAGE ON WATER HOUSE/LOT
BULKHEAD
TOTAL
7 OLD
STREET j VILLAGE DISTRICT SUB. LOT
FRIi
O�. ER OWNER ,e
-blilt°om t/ L " N Ex y t ACREA
/i tf f; r9 RCS u12 n r� sBr w.f4 t �l, - — - =C' � '� ` f
5 ` W �� �_ a r TYPE OF BUILDING /
RES. ' `` - SEAS. VL: FARM COMM. I IND. - I CB. — ! MISC. —I _--
LA-- ND N IMP. 'TOTAL DATE REMARKS
14-
'N;)
__-
- •��-'�?'� � -��'-�C� � � � � � f /�"�% � � 521
_�P
/j a--- o�- - / J / v
P dC�� J �,rD- q/qc— ll6n (5 eCJJ- C/���E F? [�t7.��7' C-,; t� ' 1i A0 Lf!`�7` fJl'7�'7@1v,r`r; y;:i
✓ �� A}~ - ! ° ` � - �G ��— [�✓�:i �9�Pt�n�f7`° irSrr S'[ tiyf G'a a/✓r1r 4 6�a -- — — - —------
� N RMAL BEL OW ' �� 9 BO
Farm 2 Acre Value Per Acre f _ _ ,� {, 174,T
K c�rf
r
' at a �?lJ
Tillable' 2 xt
Tillable, 3 - - -- -- - �- -- -',� � � _�-/ j(7
Wcodland
Swampland ---
Brushland � � z
- -----����---- - —- - - --- ,��*
House Plot-- ------ ------ -- -- - -j� `` A- _ - oC j!o { f - vr.
l r: �� ISC,i (r Ir?F�i G�PJZ�_ 'j l•.dl'i 'ffj� CCC ;—
�.� -- --�------- - -
-- --- --- --- — -- -- — — -- ------- —� � fii- 1 ! i rV Jtn --- —
`y�Cta{ „' „�` _„-_ , <•l7-!7i7 j � t � r' y-j�-- � � '7-f"rl_.
,7�ri ,,. "iJy„„rr;fi., .�'':$'4 ,� aai�a„'s� t a-.+.,Ev:3,;'�n^=^ -' -�;,a o::�?,•2•..wi.,,x,r I• +�.;;. ., / \! //�' n,
di 'ffi
dF, fx: ,4: `t�= te. •.'7`,5”' `S' .r: r.,�r S'F=. „ y:r�" .,. •'�` :'�,” cam.\
�'
).f r`',c``t 4}''N t"f,;,.T• ?�}Yf^Lwti"',,��:-
r,-. tit�:':,"�, i°�yt�t :�a'.rr -�`•r„ {1,,,`='-�er*x-.,�••t�T�'..>,5�`�ti,!,^'��,''.` �i C•»",�§3„ ''c a^� i`"`=d��` �u.vk,.c"'; 'r_ .=''x;�'_.`., 4,k 4 r
ryp l� ; ,y�^'x:T'= < ..;n2`�",,, '7..: 3,.,.• tit-"z-„ $ xz;,;,,i»;.•;+.. l;"i�
C-5 �b :tI 'J�+�' �(4:t;r�.1 X:4i'� 'n'^F`4•�r 5y`.;g= �•y j:;� � � �
f;
F1, �"v ".1'', �f�'r��"�'tt-�y)4 �=. z�Fi y%i:;iF'ki�.:vi,7:i.+ra-1p.t`,:��1„,0,,_�i3;,>�+r4�,''"1.s,�•r^'�. .r�+?�.z g=,"NKieC"M��-,��,r,`:4�a•?, ,� �i.,.�e,a'•�i=4;.` "`L "*"rt�5.ii�:2 t'�', ;i��,.�a Av-,..,.,��-..,, =`'"dot$i:4, ;t`k�`"rt+aps�:"3b=�,x,�r'eih;,r•z ®C�-�., L.(�,�-t,� f•1 �
;f 'tt' Y�xi•�kii• `sRk ?% ,�-,",w,. Zx`'%'.,:, t r�`^�''"'a \3>r- ``�`J L`h-�
t 2},`x 3� s ty c "�'Ys?�c>.f?-;�'N��:va�';s:;''4'=��s�a,;,z�� '•�z`�,�,ati�>�..,,.;,,,�,:.`x�.,�`y�'�•�.r 3^t^dc} � `s
.w '.:!% q '�+,E r',,a '�`",,'s"s„cp✓sy�-,ire,.",' 'ld. �`'*'F'�;i�.i;;ik 'i,v:...- �
r�s f'''fs;.f+•7 13;-�,,3s;i �w.r'�+irAyar?„q�A/;',;:,:k1.r;"i y�a '-> �: t,:,r �ay,
,l '�S�}-�,'2,U ie;y�"x.�s^.''F� iii'{'h.�.n``�F'sR.,,�v ?,''.t*: k`-�"f �^i 7�k�T�,h tti�y�A�'�.<'•�)`F��
s�o: �'.
'. aK:%.'T'{;'^k:.£ z:=7^..:"'y �
;-�iu'4:' _
e:y'' {,`^a,3"/', m.-Y'.,• r. ,,:;,�: 'x L4
�p�*•t xr;. ",+...�• s•�2-���S.i>�*�'a"s�-»N,�.r,ra.t.�r�r_,�'.�'{
y 7�S 's .w'_ r`.•-F
� S „`�{+d.a,, •i st`'. S'h`'.;.ax +,,__'
•��.,,z ,�'j py �f' 7 7...<l,,- +-��x
� ,�i.,�s�:�i�
:.,�.:..'1 `�tix �.•r -;ai'-:%a,z~�-�;,y��.,f: �'bi�^:?"„:a,r�n�, �
`.�'.a:•n*`, qa��',� .a•a=i7s
,f�5 s,t^;���r��v-ay 1� � ��-,.,a. nT� ..��i:a'l l�l�,��,1�`:���>✓,�•�'%5 iF — MA
_
y A
•It'�,"'1IIY' ' `€q M�i�Z>a. .rt�„v..�.,�i - I
+.3•
777777
•z`. �,^�'`'�„�- "yc�ra��f�r;s�'f.,yy5`..7 �'�_'-i",,,,,.� f�i'Ci'2”'-`r3f
}er}"�+{"':M�'°�5,.n'>rr"r.S�.y "t,�,^ ,�`A�}-,:.m.r:t,r`��' ,,•'r \a>
"J
t,r'c,.-u.r��ah.3 „,,. dt�'L.hY' ..„ "' '''., +- i '•�,' x"'�"W-*,� ,.+ t, },'F;s-a.;`i'�tt,,,; ^ F,-„r'x4,^.,,, f y, i=
''"s,.;t.•��� ,�,i, r. y x..�x.",C.,..�r,1� 3 zy; .,,vk•a�-y -� �`«1�^1 �7 x f�,.'"�.�,�;-`*�{'�'t
,G'e" ;t+u;,.::t„'� s, ;u>•%-+” ,,1�_t; +�,.�r'Etyx.,,,#„t ,�.,'F, 3: 9;.,,�`t(¢•,'�'?,'z,4 +;xv S':a.:;,.”'��y, ,,'� :i""mow:. ! - y 'y jr• - - - rtr
4}��'�%'W'!G�'k�r F�'�d�.s.-d fY».i.°,s-1�i�`r• r j.,,G^%�,.,;r^jz.,u,•F�ir_. Y.,j....v}y�'i'��_'�i` "�r�x�{! i,i' .`�'� � .,7—— _ _ — —+
) �; 't7n+'i J ' it {.- d+.h..,;.tic • i—,
s k
a .
L�i�;'��y.::�»�Saa'.'3sar3r�i"zc' :fte.:`.:,:t�:altr�2:ab».,,,. Y:a::•iw"�P� --- - ---- -- ?,t�:�,� _ -�� � - -- - -- -- --- -- ---- -- -�
50.4-21 1/06 _ `
f E- ,71C-
AsjB' ldg. SO ,Foundation �
Exn,tensioBasement— — ,,-
,«� Floors _ ,' _ l
/-rtlrs�dQ. _ I
EExter§i6ntiro ) > 7- Ext. Walls- ----- n y- ,---- Interior Finish
'Extension” .` Fire Place —i - --Heat --
fry` ---- — —---- --- — ---— —--- ----- -- —-..-,---- -------- --
.
PorchT Attic
____F
—r-—--— ---- ---- - ------ -
t Porch I Rooms 1st Floor
g ,Cum
i X S w 132 Patio Rpoms 2nd Floor
-=----- - --------- ----------— — ------------- - --------
=Garage /t? ____..; ,�, Driveway i
, ++11{{ p - - ��+•/ _ s��1y��s,�J ^�}!fj> {��t .. .`fz >{,.,+�y�^, �+- - /
4'1
J 1�" - ,e• w'n !`M\ , }J' �"l, r`,` ��i L -.. \.i'\ .'"i.. - i. LZ.Y x•� r .3d r e`
Revisions
12-06-96
05-11-99
07-06-01
08-06-04
01.13-06 Nx07U p'
03.30-06
12-01-06
11-14-08
03-09-09
12-30.16
03-2118
Pafit5 V ICCk) ILC-
Ick d - 5-[ — t — fir
cj-5 rY�a,tl r Yl�S40 :
50 — i — 17, Pit -R D 0
sOv
LONG /
• /� u
/��Q• 88A(c)
6 SOUMOLD PARK DIST.
G lip
/ 3
to
m '
�, sa OA(c) 131 �8
12A d 161
5.1A(c) N 2.3A
s; a`
4 C) (OD
6
ea2A(c) 8 22A
9 ,8
71a
ess i No a am R 19 1 �9
6 8 16 R 30A
13A(0) Rao W 15 & 8 R 20
/
5 187 a1 ba R ao
8 Po 17q(c) UA(c) R ro
4 1 7 as t c
1.1A(c) 16 S 22.2
J�(c)m 1.7 22.
189 a IIA +e
z E a 18A(c) x $
•1 rc Z23
JO
spa 13A(c) 8 as ra A
N 3169
L rayan/o.itxtro s�ePn®,tm rlu a eam lima —� oma�vn --yy��— ypnm Deme lne --x-- meaMSE auvxopEalRs
E -ZL— sm.a�.�eer<aeaa.a (21) eem xe O �-e omma2 --e-- ne„m�i.. --n-- n�xErouwexcosm�ns.s x
Ce sme,xo.tmt.� ------- O..ea oew.eea vrx.Om.e i.. --w-- Nwaaw tae--xsa-- rYiE xKOwwr
E "^ Svka Dmemm es fA+a.L.c -- ageoo.a LLr --L-- 4nam®omnm tma--w-- lld�r �3 xn1En_
N Saram/SMe ~�-- NWK f✓EFUSE
D reFd Na 2] Oee.l Ma 121 A(E)w 121-0 7o'^'t^ --- ran P.e'n aee --r-- Nue.vi.r Damm Lve--WN-- NaBUTANCE aua51EW
C.bamdae. 121 A(c) Naae aea ----- Saw.Daae tnv --
LEGEND
i PROJECT
/ PROPERTY LINE
/ SOUTHOLDEXISTING 137 SF WOOD EXISTING 492 SF
DECK AND 7'-0"X7'-0"SPA PARTIALLY COVERED / APPROX. 56 SF APPROX.459 SF PORTION OF 1ST RIGHT-OF-WAY LINE
r / 1900 HYATT RD PORTION OF 1ST FLOOR TO BE DEMOLISHED(TO TOP
TO BE REMOVED AND WOOD DECK TO BE PROJECT-LIMITING FENCE
'� OWNER: GEORGE DANGAS FLOOR TO BE OF FOUNDATION)AND .�.n�����.����
REPLACED WITH 186 SF DEMOLISHED AND �� /
SAND PATIO REMOVED �o� EXISTING 105 SF RER AN EMOVED ALTERATION,
RECONSTRUCTED OUTLINE OF PROPOSED RESIDENCE
I � BRICK PATIO TO BE I ALTERATION,TYP. ------------------ EXISTING TO BE REMOVED
III E I II 5 - --- -
S 64'50'00'! = - ; , ,
' I ' REMOVED
$N 316.5 7' I WOOD RETAINING WALL SPIKE PANTS VIEW LLC
EXISTING TO REMAIN
� - - . I I •',I ' ' �-- -- - - - 2022 HYATT RD.
i I ---
>
RICK �' m R - --- -----------
U. .I �3_5's------------_ ---- -� SOUTHOLD, NY 11971
SHOWER) P
\ $a n I W PSE -Z ------ ---J °' 3.0'S'
' - __
OUTLINE OF PROPOSED ALTERATION SCTM#1000-50-1-21
II i Q i w iD00��.........�4�_.i I1 35.1' G ------ _ ------ o _ �.
I =- ------------------
Cp I I I z 18 W ---- EXISTING PICKET FENCE
W I I N r i---+ -� / GEN28.2' ; 12.4 TO BE REMOVED
O I I ,_ r '-- I -- -- 69,5 I . ARCHITECT
6 . kLJ I L'1 ' r i ;; / / INGROUND i ,• N
0) l I P I Z I I__-: v Y' I POOL i I.
11J E` 0 15.4r I g I EXISTING TO REMAIN E R �'/
II Iz N' -� t...-• --+'o, N 2 STY I! i ' %/j' I O)
�pN '\ -- I BRI K i LY FRAME DWELLING 'r-- /20.1_i/ I i it
N 11 4'I- w FFL 42.7 I / ---- I
I I pooK o� o' 2 BAY BRICK PATIO PERGOLA TO BE ELIZABETH ROBERTS ARCHITECTS
\ ) �T ,/ ' 0.s' #202 14:6' '/G� - J F� PERMANENTLY REMOVED 168 7TH STREET 3C
FLAG o Iy O - - --- j -�!p� ' _ EC
s. POLE OOD Wq I .O \ SPA I I I ? !o! '�' „ F '� I '`� ------------------- -- </yF F-� ; BROOKLYN, NY 11215
�k I �, I I i` ;r o �, p� I PERGOLA GATE 7185045488
4' �_-----_----
U W' to ��dIII I -----------
N I I� PP TIMBER wA L i �'- " Ld I _ h ----- ------U EXISTING TO BE PERMANENTLY REMOVED
, ----------
/> + \ ---____-- I --- - ---_ --= GATE
1.8' '�BALCONY ;2 3' i I L�_W------- J ~ O N
2' L L - �_� EXISTING RETAINING WALL
'Z i I I j 1 ` r =, - *_= -,-__ 6 II AND CURB TO BE REMOVED
P 37
31,879.06 SQ.FT. �' I I ----- ......... ----------------- 21'5'
N PROJECT-Lf MITI Nb FENCE wi 1
�l 0.73 ACRES i E CLOSED AREA=16,954 SF Q
39'2 ,GARAGE EXISTING TO BE DEMOLISHED AND
II STON DRIVEWAY GF 39.0 ,-.Y;
' I i GARAGE TO BE RECONSTRUCTED/MODIFIED
I
,�-_ - - __-.----- -- -_-_ I PERMANENTLY REMOVED
-------------- - o
LO 4j I5 R.0.W.
`
C,4
/ EXISTING SANITARY TO BE NEW CONSTRUCTION
I w° L SRA�EL DRIVEWAY REMOVED AND REPLACED
' ENCPROVIDE OPENIE-TwIt UFWAY I / I WITH I/A SYSTEM
\ I I STONEWALL -
irl
i I I I 323.45' i sPIKE SITE DAT A
N 64°50'00" W
EXISTING 175 SF I Z PERGOLA TO BE PROPOSED 762 SF COVERED PORCH EXISTING STONE AND GRAVEL LOT
BRICK PATIOS AND - CODE EXISTING PROPOSED
aI DEMOLISHED AND ROOFED-OVER DECK TO BE DRIVEWAY TO BE REMOVED AND BUILDABLE LAND AREA 14,835 NO CHANGE
WALK REMOVED (Z REMOVED DEMOLISHED. REPLACED WITH PERVIOUS
a01 O 2070 HYATT RD EXISTING WELL TO ENTRY TO HOUSE GRAVEL DRIVEWAY COVERAGE (%) 20% 26.1% 21,1
&FM010! UOWNER: PHILLIP LIM BE ABANDONED TO BE MODIFIED. COVERAGE (SF) 3,871 3,134
NG PLOT PLAN o FRONTAGE 99.62 NO CHANGE
HOUSE
MAX. HEIGHT 35' 25' NO CHANGE
FRONT YARD SETBACK 40' 69.5' NO CHANGE
SIDE YARD SETBACK 15'-20' 10.1' NO CHANGE
# OF BEDROOMS 5 6
/ LOT COVERAGE AREAS
/
EXISTING
/ NON-ROOFED NAME EXISTING PROPOSED
1900 HYATE DA SHOVER TO REMAIN 1,853 SF 1,796 SF
OWNER: GEORGE DANGAS HOUSE
vo / NEW STEPS UP TO PROPOSED EXIST.ELEC. METER OVERHEAD COVERED PORCH/WOOf) DECK 145 SF 762 SF
1ST FLOOR ROOFED-OVER
WRAP-AROUND WOOD DECK I ELECTRICAL SERVICE WATERSIDE DECK PARTIALLY 492 SF -
S 6;4°50 00 E _ I 5' J 316.57' I wooD RETAINING WALL COVERED WITH PERGOLA
i I. I i' t SPIKE -
- U.P. 3.5'S SP 9 SF
A
II ' crl 14' s.a 6'x8 I o 3.o s - SPA DECK 4
-- -_.o SHOWER' DIN --ELEC_LIfVE, - - - -------- °' `
OGEN. 0.8,w- POOL 137 SF -
Ljj
576 SF 576 SF
COI I I I m 1 r 35.1' 0 28.2' 1 .4'
PERGOLA OVER BRICK 226 SF
1 I I u I; O ` i r 2 STY 69.5' GARAGE 393 SF
I � I wI m .w I oCN
Z i b r o FRAME DWELLING co INGROUND ;
W Oj +w FFL 42.7 I POOL
N > w N #2022
oII
I- o 0 28.2' I TOTAL 3,871 SF 3,134 SF
O ! N',I Q LL o d.8' I 1,005 SF ON-GRADE (26.1%) (21.1
�^ I o I, - __ SAND 3 + MASONRY PATIO
POLE w00p wqC I O PATIO I 0.5' �: `, 4.5 I 1
I os'
TIMBER wAL t ` L6 I SANITARY SYSTEM DESIGN
K
s.3' 27 GR I -
1
N
Tri------------ ' - 5.3' ADS
Vd
BALCONY p
N 22.3 MASONRYI DW POOL BACKWASH A/I SYSTEM
Bo + a + + 16� 6'X 4'DEEP
31,879.06 SUT. I G i I 0 I II
PROJECT-LIMITING FENCE I 6 BEDROOMS
0.73 ACRES I I LJ, LP
ENCLOSED AREA= 16,954 SF z h 8'X16'
I J o I/A=HYDROACTION AN600
l I w I j o 4'-0"POOL CODE COMPLIANT
I
100' rg CK----__-_- ___-- - -- _ I � r-- FENCE AND GATES,TYP.
i m D I EP ° LEACHING
o -F- - - x4' 8' 8'x - - - 3 ' N [1] 8'X16' DEEP LEACHING POOL ISSUE
NO. DESCRIPTION
-- i' i [1] 8'X16' DEEP EXPANSION POOLtj
DATE
II �5 R''�'W' N 1. I NEW UA SANITARY SYSTEM DEPTH TO HEGW 20' 01 08/02/2021 DOB FILING
--
IE
PROVIDE OPENING IN I �------ ---------- 1
O ~ NC AY ------ --- --I --- - - - - - - ------- - 1
I EXCAVATE EXCAVATION FOR THE LEACHING POOL MUST
TO GOOD SOIL CONDITIONS SW 58 FEET
LOCATION OF NEW WELL W/ �G
A PROTECTIVE BOLLARDS.WELL
BELOW GRADE & BACKFILL WITH CLEAN SAND AND
I I I I 32 3.45 SPIKE MIN. 12"FROM
TO BE I GRAVEL
1 PROPERTY LINE
N 64°50'00" W I ` ' � � ', I - `�`,
{ I I w APPROX. 226 SF PROPOSED 762 SF 1ST I NEW 18"X18"CATCH NEW PERVIOUS
Z
PORTION OF EXISTINGROOFED-OVER - .
FLOOR
� - BASIN
GRAV
EL DRIVEWAY
al 2ND FLOOR ROOF AND WRAP-AROUND WOOD S T O R M W A T E R TITLE
�I Z 66 SF BALCONY TO BE DECK
olo RECONSTRUCTED 2070 HYATT RD DRAINAGE DESIGN
O I IN-PLACE OVER OWNER: PHILLIP LIM PROPOSED PLOT
SED PLOT PLAN I� ( PROPOSED
(j)-72ET Iw ROOFED-OVER DECK DRIVEWAY
3,325 SF X 2" = 554 CF PLAN + SITE DATA SEP 20?1
PROPOSED �, ,.,F
14 LF OF 8' DIA LEACHING
HOUSE
PLOT PLAN NOTES
1,800 SF X 2" = 300 CF
USE: [1] 8' DIA X 4' DEEP = 169 CF SEAL AND SIGNATURE DATE:08/02/2021
PLOT PLAN MAP INFORMATION TAKEN FROM SURVEY [1] 8' DIA X 8' DEEP = 178 CF
DONE BY KENNETH M WOYCHUK LAND SURVEYING, PLLC. 347 CF �RED Ahc PROJECT M 1922_HYATT RD
P.O. 153 AQUEBOGUE, NEW YORK 119. 'Si��
POOL BACKWASH �tL DRAWING BY: CM
SURVEY OF PROPERTY SITUATED IN SOUTHOLD, TOWN OF [1] 6' DIA X 4' DEEP CHECK BY: AV
SOUTHOLD, SUFFOLK COUNTY, NY.
S.C. TAX MAP No.: 1000 SECT. 50 BLOCK 1 LOT 2 SEE SANITARY SITE PLAN PREPARED BY JOSEPH N�y�, o386s3 oQ� DRAWING No:
FISCHETTI, PE, DATED JULY 24, 2021 FOR ADDITIONAL FoF NE`Ny G N-100.00
SURVEY DATED: JUNE 3, 2020 DETAILS.
NOTE:IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A
LICENSED ARCHITECT,TO ALTER ANY ITEM ON THIS DRAWING IN ANY WAY.IF ANY ITEM ON THIS
DRAWING IS ALTERED,THE ALTERING ARCHITECT SHALL AFFIX TO HIS/HER ITEM THE SEAL AND THE
NOTATION"ALTERED BY"FOLLOWED BY HIS/HER SIGNATURE AND THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE ALTERATION.
S.C.T.M.# DISTRICT: 1000 SECTION: 50 BLOCK: 1 LOT: 2 & 21
rAD
,
o
N
'� V,
I^b CO 7 00J�
N
FLAG&
POLE 16
O• p I
O `
0.9 '
/ S.C.T.M.#1000-50-1-21 /
31,879.06 SQ.Fr.
0.73 ACRES ^- low !ems
15,285 S.F. LANDWARD OF BLUFF /
A,61. \ / ATH A7104 •'itii8:i:::33•�.
5000" :SPA. ry:`. :`: : :;::;: :: ::::.
V.,:: r6
o ....................... %.
:::.0 NN
Vir
.......
/A' QbY :•::-r:..
3 Sw•
,1
40.OAK
�� ryry i' �� tp°pgoF:: ::::::::•:::::;•::" 7 t 000"� ��
res CP
ti
\ %,OIL
/• 6
O 392' O �`
SPRUCE 0.3
ELEV. 37.7
00 / AY
/ w ; \ MIXED SAND
cRAGu oRNEWAY •.•..d.'..•' 1s+' �r, s� ' LOAM FINES
M 2'
SPIKE BROWN
::::::'•:: :: 73.7
54.9'sn
&$ C LAYEY SAN
: `: GRAVEL
IN/LAYERS
32/g5 WEU
:;::• ::::: ; 31'
LOT 21 (. WATER IN
.. GRAVEL DRNLIYAY 2
TOWN OF SOUTHOLD :. $? .'; ':'-i �.P. BROWN
CLAYEY SAN
LOT COVERAGE SAKE s' S.C.T.M.g1000-50-1-2 SC W/GRAVEL
BASED ON 14,835 S.F. a �'� 16,604.61 SQ.Fr. IN LAYERS
LANDWARD OF COASTAL EROSION HAZARD BOUNDARY SObo F 60 ACRES �
�• 60 ^i
Y \ to 58'
HOUSE W/COVERED PORCH: 1998 S.F.
OUTDOOR SHOWER: 22 S.F. N \ G, Off' WATER IN
REAR PERGOLA OVER DECK: 226 S.F. oBROWN
SPA: 49 S.F. s� o �+ FINE TO
SPA DECK: 137 S.F. c '�' \
� COARSE SAND
WATERSIDE WOOD DECK: 266 S.F.
POOL: 576 S.F. N
sQ
PERGOLA OVER BRICK: 226 S.F. 64'JUNE 10, 2020
GARAGE: 393 S.F.
McDONALD GEOSCIENCE
TOTAL: 3893 S.F or 26.2% REBAR
G I-TI
t` THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL
A
c ;=. FLOOD MAP#36103CO154H
AND OR FROM FIELD
SERVA710NS
FROM OTHERS
c
C N
AREA: ELEVAnoN DATUM: NAVD88
UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COP/ES OF THIS SURVEY
n MAP NOT BEARING THE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN
ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS777U7701V
f
LISTED HEREON, AND TO 7HE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE.
THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO 77-IE S7RUC7URES ARE FOR A SPECIFIC PURPOSE AND USE 7HEREFORE THEY ARE
NOT INTENDED TO MONUMENT 77-IE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS EASEMENTS
AND/OR SUBSURFACE S7RUC7URES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY
SURVEY OF:DESCRIBED PROPERTIES CERTIFIED TO: PANTS VIEW LLC;
MAP OF: PANTS VIEW 2 LLC;
FILED:
SITUATED AT:SOUTHOLD
TOWN OF:SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC
SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design
lr d+ P.O. Bos 153 Aquebogue, New York 11931
FILE #220-47 SCALE:1"=30' DATE: JUNE 3., 2020 N.YS. LISC. NO. 050882 PHONE (631)298-1588 FAX (631) 298-1588