HomeMy WebLinkAbout47219-Z � 2l GENERAC® M O V24 ®� ®� /�-� GUARDIAN° SERIES _ Residential Standby Generators Air-Cooled Gas Engine_ INCLUDES: Standby Power Rating G007038-1,G007039-1,G007038-3,G007039-3(Aluminum-Bisque)-20 kW 60 Hz • True PowerTM Electrical Technology G007042-2,G007043-2,G007042-3,G007043-3(Aluminum-Bisque)-22 kW 60 Hz G007209-0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution'"controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available 4sF��f�'�� �'�s^'✓;a6Nn • tr,; Electronic governor NA F y..`. , • Standard Wi-Fi®connectivity ��" ." s- -`� )`r� A • System status&maintenance interval LED indicators `r,�,;q"=z_; " • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP g GfER f as operation • 5 Year limited warranty Listed and labeled by the Southwest a r,- • t R search Institute allowing ; ,�°f�y1���`��;�� $fi�;���w;;r;,�s�;�se,7'g,� installation as close as 18 in(457 mm)to a structure.' "Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. https:l/assets swri.org/6brarylDirectoryOfListedProducts/ or C u� Us QV I Constructionlndustryl973_DoC 204 13204-01-0i Rev9.pdf "� LISTED u .117 Note.CETL or CUL certification only applies to unbundled units and units ppaackaged with limited circuit switches.Units packaged with the Smart Switch are E1L or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success to providing the most reliable generators possible, Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els.It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most.The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABIUTY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER—ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MGI-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEWT' TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators,Mobile Link Wi-FI allows users to monitor generator status from any- Switch integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smartphone,tablet,or PC.Easily access information such sumption data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer for fast,friendly,and proactive service.With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage. low cost tool which helps save money over the life of the generator Included with model G001210-0. w N E R A C �_ w GENERAC'PROMISE PWRIM GENERAC® 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma molt' rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. f 6 • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch(if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution-Controls • AUTO/MANUAIIOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. - • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. GENERAC® r 20/22/24 kW Features and Benefits M Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity(Wi-Ft equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 20/22/24 kW Specifications CM Generator Madel G007038-1 0007042-2 G007038-3 6007042-3 G007209-0 0007039-1 G007043-2 6007039-3 G007043-3 G007210-0 ,Rated maximum Conti u (20 kW) (22 kW)" (20 kW) (22 kW) (24 kW) n ous 20 000 Wa ;2`O II Watt 0 _. :{ 0:0001Vatts_, ` ,qv-3 , Cts'•;, -2, 0 r . s?`,-d=`24. OU,tiVatts4 Rated maximum continuous power capacity(NG) 18,000 Wafts*y 19,500 Watts' 18,000 Watts' 19,500 Watts' y 21,000 Watts' }., -:" s`>�%�:- :�x - ,"IT"5"s'�ry->.. ;::t'.• r•J•.3 m' = +ac-as'3 _ *.^r s's's Rated of _ _ .x r,o„ - _ RevtaeFx 9 r<FY !f a Rated maximum continuous load current-240 volts(LP/NG 83.3 75.0 u91.7 81 3f -y'<V y< •?.5 y - ( ) / /8 83.3/75.0 � 917/813 > - 100/$7.5 1 "=x4:,_ :>r';,<,°�.r z;r;^-:az»�yrr;�' a %a�,:E;r„�, - `Total Harrito<ie D)stdrlibn�' _�- ,,�, T �=E_- r. .� __.,, -x_✓- a"ur,'Main line linecircuitfibreaker� �` � .�x r. 90amp.m 100 amp 90 amp- 100 amp 100amp t _ .'aa+,_-..4K;ff.S. ,;.....,,.,< ..s»_>:5, ..,c,<.,,,,,.,!-,>e.,r x,_ Number of rotor poles ,P Ir = ate A ;x=<Aa<- . Power factor . I.t.<s ^ _,- n, ,,, . -- =_<',, 10 `!' - _ In Unit mor,Gioutu1�SUCCA°riiini' ...,sss_xs"2asHa "3.5AG a` _<�u Unit weight(Ib/kg) Y' NF 448/203 466/211< 436/198 445/202 455/206 .,DlmenSldnS.'(:X•&)@,,gX,A,, .>" %::Ij� .. .,'SF `=r > ;-=":' •1 A':'JAS".,} - ^lY r' ,r" Sound output in dB((AjA)at 23 ft(7 m)withgeneratoroperating at normal load"' 67 67<, 67 67 67 Sduiid,ori'tit in tl8/A`eC23 it/-7tfi ith'e7 oerator iiillufei �'s logs'ed'eae�cfsitibtl n-5 '5= fP, 4 FxerClSe duration- ..�_ . .,,,�,vs„> ._.<__,. ,<e,,,<,- .C-.,�..,<.",.",,. ,.:<... ,�. .s 5 mint Engine Engine type GENERAC G-Force 1000 Series ,,_�,+,„ "'2s>;"<, :`�sx`�,Prr 3bs'xv>,�•axFS'- - -�'w�-,i�tX "- ;,-�::"rr.�= ;r" - •:r - aYr _ ^r^Y"�.,,r ;`NUmbe`ratCllnders�= .'��`�,.r...:A-_..-z,.r,...,_-..,,,.'��':rK..,«.,.,.s.,m_.;ri'=zz•.;.r�<" . .. .,..s,.., .mak„ y.,,. .;>i'fH;: . .�-"->. <,_, Displacement 999 cc Cyl ntlei`biiSck. -t_uminui'n �:".�<.,t;��' ='.uy,;� F' -xa:',�g�z ��<.. ,;�s,. �.w;=�:•`_;��s�'�3="A /,_ a n""siemr �•_�,tr�:-`,s, a. Valve arrangement Overhead valve `I fllttOh S B Q. .k> =�;, z-cep. i"� %`�'�', r_%!a�><�'w.� �lr^•,r�r'<l* "�i"�^3'= �.�" >�`A'aye� ,>rt.� . ,;...,.v.,<.... Governor system Electronic , ;� ,i'x -;;1'•-P5y:` :moi. ,rs,x� ts`af��„ ,,� � ;=a3;Js''<,<' cts,,,,,,�a�s�.�,�,est„n,�aaaw;z;,.,_,-a;�aS�w`,'`„<<,�.�,,._,�z,",n�: Starter 12 VDC . _.,,_ ... �>t> �..h<.3„_<....�.P.,,. YOperating rpm T. >,f 3,600 audeti,iy%a;ol,ng`s-aumtri-o�n,„,�-re,.r.alC;-m„u=<'aA`�',;,r-"r<✓t�k-„:3"e.,.„ti�r^.`{5r�:s`tif^„€>%zf:9"Ex`"Y'Y%,i::iir.`°`:,',��i�§��.�s,.��s.��a„y,�...�_��:'f4;sez7J�!t,ll.V�<,:ua=���;_�`-,:,�sem`z�"f.s'_s-,�-'✓estt-� ft ' x : m -{`A:;.�r�.<5.�..I_&”-)>�y>s,#x.F-„z,,-';%_.._,'FT","y�x.-#rz.+„'.n,>',,:,,c<,c-,2:z^=e�•;`�{(cs�t�4s--).�-�:s`-s^":.t,-<;z-'o- `t�:,�iti•`.,-.��:' .r_=.z17-.;,^-d`;�.• ;,�,:�<r, N�,r-,;�;,z':,..i:A`.t„b;,�,•�r�„fi,,�-*µ-x.,x�=.s ns164ta.6�) •`'?`;„2 )i,r � ns` i<= ."�, ",,. �`i ,} .v� .�'r+F<,�ar,sr��„ ,,,�,��°4;'"301;f�52�°� ;•327:9:26' ,,,287'/$�t$` .;,. :308 8 6 .�„},>'� ,5, ,lj'.Ya �."<'?r::it,'k"r f5talf:La li'K-'._`,>�s•Y-rW',< >h K5h, -G rZef,. rk, k"(.�,s-)1Y'"'Sv .\ «' ;:?E+`r„ aX 1.r�5i.Y,M>k'yl'.nv,rS,�Ls .,G> >�.ar7 f_cfz' t;T'✓xa_ f°7+.yS w '✓�° y._,. r� <z6% A0.-, z4,+;'^", s„rh +. ,r-: ati' al ,.A ,' s, -t- q P /ft` /b WAR ,s:>:, ° . r st, Y' .,:�-�, ��1 d��-' _,� �: _ �2 2.2 3” 57. - 6-'2 6,8.95�>�;.- `92�2:5�` f.':' `w` -ht yy " ;:Lt'�'',•�'' '� t X3'0” ,- >, ra=<s �`d�:'..3,'�¢:,.x>E-�;s... =3�':, Note:Fuel pipe must be s'IM for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0 87-174 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas For BTU content,multi I 113/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. anutili<'tailure.-VJeeklY ;;Bi=weekl;ntMontti►"-sel'ecta6feeice�ciser;.>,., „� _ru.::�a.,.<..,_�._, . MANUAL _ ✓Start with starter control,unit stays on If utility fails,transfer to load takes place(' StsdrP'o'xi>srerioGed ReadytoRun/Mamtenance messages ; Standard e s -tea,-=w .i 5>;:E:r;-,-., .."•ix",-,„re^ - _ - _. ,, "-2 sr -" _ _ - x>•Y;' x "<-+.,:,.v;"`.. ""En A irie'run hbuis'iritlicatjiin=ty% ' c r,* .-."�_<eer.,Ly :ti-`,�,".,:,�r,C_>�.�>s`.<,_rr-sai'a�'...«..f>�„,;�,.,•'.<„>«<> , _,,.>�<..,,.,..-.,-,.,,., - °`r.`r,�Staimda r d�: ��_-`.,a.•`,';v,s'., ._�s.�,s�..,-- .__......s. �E'4-4,f;1 7J Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) t z>J"6^ :L''.'xa'n:: -;}^:eX�tj���h",tid;x :i-`a _ _ _ ,kl,,`s^ '.,�•�,45✓,,.Sir.,;-k. t it et m,tdtlili°;tdstafiltiro Ud yUoltageLoss7R a t_ty! elu d( Future Set Capable Exerciser/Exercise Set Error warningm Standard u Alaim%Mantenancel �50'events�eacl{'-�= ., .. Engine start sequence Cyclic cranking 16 sec on,7 rest(90 sec maximum duration).L ..< r„yr< ) - ,.�,:� ..tom -” " ” Starter lock-out �,Staher canobt7e=en` 'e until 5 see after - .<.,.._h:,..::,w, , ��.%`°�.«-, .�_" ��-=�- _ ” >., gag Smart Battery Charger~ Standard F, =i;.c�`fiYZ`{; ,e,•= - = :'c'-f,',.Y”' ;�.y; „y,, .P,` .;w;,r.a Char er`Faul issffi C`warnln : .t Standard ,_tee ..:, ,. ._�. t;>..,..,."._ ., ._ •:t'>, . ^. ..,. , , < 4» Low Battery/Battery Problem Protection and Battery Condition Indication Standard k - _ ': y `f'" - rAutorriahc-Vo tags Regu a n, Ih _nil U er, o tame ofection' ;�`�== ,rs�: 'Standafd;w'��:; � .ita.": `w^;,.,.rys Under-Frequency/Overload/Stepper Overcurrent Protection Standard Stand`id=` :Sate"Fus Flise`Problem 1 t n.�a -” Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard" ,Over ran eed, 72,Hz mSen`eL'ossShutdo n'; Standartl> High Engine Temperature Shutdown Standard In a na aulUlnco 1 r I F rrestMinn Wi`I ` 66 on' - - Standard g pr Common external fault capability Standard xFleld radablefirmvrare'=' Standard moi= "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator maybe higher depending on installation parameters Rating definitions-Standby-Applicable for supplying emergency power for the duration of the utility power outage No overload capability Is available for this rating (All ratings in accordance with BS5514,IS03046 and DIN6271) 'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megaloule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3 5%for each 1,000 it(304.8 m)above sea level,and also will decrease approximately 1%for each 10'F(6'C)above 60°F(16°C) GENERAC* r ti 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model 13007039.1,6007039-3(20 kW) • Intelligently manages to four air conditioner G007043-2,0007043-3(22 kW) g y g p r dit oner loads with no additional hardware. .: z tw ,-1Ati rw; rM >No,'of.pgleS:3f; ' _' r' ,., r4..3.i"3u,.�,"e::.�. • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Current rating(amps) 200 with Smart Management Modules(SMMs). ng t�ti~altage rails AC> •s;rr�_�:�;�����:-� �-%���0`1� �����.-�r�.�--�, • Electrically operated,mechanically-held contacts for fast,clean connections. Utility voltage monitor(fixed)* • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Pick-up 80% -Dropout _ 65% • 2-pole,250 VAC contactors. i tur 3o ufit�r,` ),,C ,(% ! �A;. ,- • Service equipment rated,dual Coil design. Exercises bi-weekly for 5Yminutes* Standard • Rated for bosh aluminum and copper conductors. Enclosure type NEMA/UL 31`1 • Main contacts are silver _ .0 r- �� � � I plated or silver alloy to resist welding and sticking. IGircui a� k A= t?ak'eOtl:ctetl '3`d?3, r-Yu, .:^.��''�-§ '`Ce'iG4 df) n<c",sY"u,•:d.TKr,..^.a 'rg, `d; s3 '%e4`'fii+ir • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly w, 200 Amps 120/240,18 Open Transition Service Rated Height ` ,.:, ; r; j'. g Width P .,Kll H1 H2 W1 W2 De ih s fgV in 26.8 30.1 10.5 1 13.5 6.9 1 B. cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges "'W Conductor Lug Neutral Lug Ground Luger ':w 250 MCM-#6 350 MCM-#6 2/0-#14 oFrrri I--we—J PWRview Automatic Transfer Switch Features model 6007210-0(24 kW Q' • Integrated PWRview monitor providesreal-time energy usage data through PWRview app. nt rating(amps) 200 • Intelligently manages up to four air conditioner loads with no additional hardware. Current e_atin G s '2-'4tT il3t • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(fixed)* with Smart Management Modules(SMMs). -Pick-up 80% -Dropout 65% • Electricallyoperated,mechanically-held contacts for fast,clean connections. P Y • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bl-weekly for 5 minutes* Standard_ • 2-pole,250 VAC contactors. ��� o%ULI sfe ���� x:>%�y;�r-. [laid: ;, yrs �✓s;�:��a, • Service equipment rated,dual coil design. Enclosure type NEMA 3R 9 d-^r:• � a-`x,,.,-•;x-"*f'3 � ��y z;"' � �-'rte-`: ��° ?;�',r:,�%�� • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution controller • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bl-weekly,or monthly • Heavy duty Generac Contactor is an ETL recognized device. w' TTP- Dimensions y3' 200 Amps 120/240,18 t.' Open Transition Service Rated `f= •_ Height Width ", 3�`.m'y�v3i•`M��sit` Hi H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges oEPTM Conductor Lug Neutral Lug Ground Lug 250 MCM-#6 350 MCM-#6 2/0-#14 GENERAC" 20/22/24 kW Available Accessories 0005819-OJs �26R Wet Cell Battery ^E ery standby generator requires a battery to start the system.Generac offers the recommended 26R wetcell battery for I ;use with all air-cooled standby product(excluding PowerPact®). G007101-0 j attery Pad Warmer - '- Pad'warmer rests under the battery.Recommended for usetemperature regularly falls below_01(-18'C).(Not—neC-1 essary for use with AGM style batteries). 007102-0 loll Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature—regulady-fillsbel—awO c_F(_-1 8_0C_) ___1 150_071-073T__ breather Warmer v Breatherwarmeris for use in cold weather applications.For use with EvEdl_ort—controEr-so—nly in climates where heavy icing occurs. 1-6-00562f-F—Ruxiliary Transfer W�tcF_The auxiliary—transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be I I I Contact Kit needed.Not compatible with 50 amp pre-wired switches. rG0_07_0r74-Bisque )FasciaBase—Wrap—KR '--Thefasciabase wrap—snaps together—around the—bottom of the new air cooled—gene'r-ators.This offers—a 'contoured (Standard on 22 k" appearance as well as offering protection from rodents-and insects by-covering the lifting holes located In the-base. rosu_r0i-scratched or damaged,—tis ir�p—oi;i�nt—to—touch-uFth-e-p7in-t-oC�ro—te�t-from'fuiu—recir corrosion 'GO05703 -0-Bisque Touch-Up Paint Kit �'ff the generator enc I The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. 066465-0 -'Scheduled Maintenance Kit enerac!s scheduled mili—ntecarica kit provides all the items necessary to perform complete routine maintenance on a iG Generac:automatic standby generator(oil not Included). 35007005-0 Wi-H LP Tank Fuel Level IThe WI-FI enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor 1P tanks fuel level Is an Important step In verifying the generator Is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LID tank is In need of a refill. Sta- tus '212 007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance,of a standby generator.It manages large elec- G007006-0 tdcal loads upon startup and sheds them to aid in recovery when overloaded,In many cases,using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0-413 LTE IMobile Link Cellular iThe Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world,using q ticz� G007170-0-WI-FV lAccessodes a smart phone,tablet,or PC.Easily access Information such as the current operating status and maintenance alerts.Us- Ethernet I lers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, Fusers are taken care of before the next power outage. 200700-0-Bisque ;Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & PCs Model UPC 6376 146 12 amIn.- 0 ) G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727.2.. [2"Iro G007042-3 696471074208 G007043-2 696471074215 NMI G007043-3 696471074215 Ito G007209-0 696471071511 G007210-0 696471078220 "MEMEMM 64B mm 1232 mm [25 51nj 148 5 In LEFT SIDE VIEW FRONT MEW Dimensions shown are approximate.See Installation manual for exact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERA_ CO Generac Power Systems,Inc. - S45 W29290 HWY.59,Waukesha,W1 53189 - generac.com WMEMSEEM 02020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Part No ACOM7814 Rev.A 07/1512020