Loading...
HomeMy WebLinkAbout27040-Z Apt 154FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No Z-28808 Date AUGUST 27, 2002 THIS CERTIFIES that the building MULTIPLE RESIDENCE Location of Property 100 BRECKNOCK ROAD-APT #154 GREENPORT, N.Y. House No. Street Hamlet County Tax Map No. 1000 Section 35 Block i Lot 25 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated DECEMBER 21, 2000 pursuant to which Building Permit No. 27040-Z dated FEBRUARY 2, 2001 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is APT #154 -MULTIPLE RESIDENCE-UNIT PLAN E AS APPLIED FOR. The certificate is issued to PECONIC ~NDING AT SOUTHOLD, INC. (owners) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL C10-97-11 - JUNE 21, 2002 UNDERWRITERS CERTIFICATE NO. 1063270 JULY 1I, 2002 PLUMBERS CERTIFICATION DATED JUNE 14, 2002 - HARDY PLUMBING & HEATING Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEP~&RTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: For new building or new use: 1. Final surVey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Cornmercial building, industrial building, .multiple r~idence,s and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. Bo For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property shew'rog all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a C~rtificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. Co Fees 1. ~erti~cate ~f ~ccupan~y - New dwe~~ing $25~~~~ Additi~ns t~ dwe~~ing $25.~~~ A~terati~ns t~ dwe~~ing $25.~~~ Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building - $100.00 3. Photocopy of Certificate of Occupancy - $ 0.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy - Residential $15.00, Commercial $15.00 New Constmctiort: L0~ation of Property: /~q" E - House N~. Owner or Owners of Property: e~C.~ to_ Suffolk County Tax Map No 1000, Section Subdivision Old or Pre-existing Building: Street Permit No. Health Dept. Approval: Planning Board Approval: Date of Permit. "ir. ~./.aaa Request for: Temporary Certificate Fee Submitted: $ Date· (check one) Hamlet Block Filed Map. Applicant: Underwriters Approval: Final Certificate: ~ Lot 2f Lot: (check one) Applicant Signature Dennis M. Wilhelm FINAL INSPECTION REPORT Sidney B, Bowne & Son Consulting Engineers 235 E. Jericho Tpke., Mineola, NY 11501 PECONIC LANDING TOWN OF SOUTHOLD APARTMENT BUILD1NG PERMIT NO.: 27040 Z UNIT NO.: /_~' ¢ In accordance with the Agreement between the Town of Southold and Sidney B. Bowne & Son, LLP, Consulting Engineers, dated January 14, 2000, for professional engineering services relating to the above project, we have completed the final inspection for the subject premises. In addition, we have reviewed inspection reports and other relevant material for conformance to the requirements of the Town Building Department for a Certificate of Occupancy. Based on this review, we have no objection to the issuance of a Certificate of Occupancy for the subject unit. By: . Dated: Gino N. Aiello, P.E. BARTONScAssoCIATES A R (; H I T E C T S · P L A N N E R S August 2, 2002 Mr. Michael J. Verity Code Enforcement Officer Southold Town Hall 53095 Main Road P.O. Box 1179 Southold, NY 11971-1179 PECONIC LANDING PROJECTS. Re: Apartment Unit #154, Code Certification. Dear Mike: In reference to the above-mentioned project we, Barton & Associates, (Architects of Record for said Project), hereby certify that to the best of our knowledge, information and belief that Apartment Unit #154 has been constructed in compliance with all applicable laws, codes and ordinances. 700 E. Main Sm~et, 3id Floor No~ ristown, PA 19401-4102 p 61{).930.2800 t 610.930.2808 Very truly your; BARTON & ASSOCIATES, LP Frank P. Laughlin, RA Senior Vice President CC; Dennis M. Wilhelm, RLS Al Broszeit, E&F Walsh Bob Ellis, O/N Ru~ 05 02 08:56a P,O, D P.1 RECEIVED C~2', ~. L~C... F~x (63]) 765-1823 Telephone (631) 765-160 BUILDING DEPPuKTMENT TOW~N OF SOIUTHOLD ~CERTIFICAT. ION lead. / tify t' ~t thc :;older usexl in the watez supply system contains less than 2/10 of 1% (Plumbers HARDY PLUMBI'NG, HEATING & AI'R CONDI'TI'ONI'NG, INC. RECEIVED 1654 COUNTY ROAD 39 SOUTHAMPTON~ NY 11968 631-283-9333 TEL~ 631-204-:1.:L28 FAX 8/01/200 E & F Walsh Building Co. 1205 Main Road Greenport, NY 11944 Re: Apartment Building Peconic Landing To whom it may concern: All plumbing work installed by Hardy Plumbing in the apartment building at 1205 Main Rd in Gmenport is in accordance with all state and local codes. The Town of Southold building department has inspected all work and all the plumbing has passed all required inspections. Hardy Plumbing operates under plumbing licenses #P1593. Paul S. Child can answer any questions at the above address and phone number. The job reference number is NC 1924. Paul S. Child New Construction Manager 889 South 2nd Street Ronkonkoma, New York 11779 631-981-8000 NFP 01-02 July 22, 2002 E & F Walsh Building Company, LLC 1375 Kings Highway East Fairfield, CT 06430 RE: Peconic Landing 1205 Rt. 25 Greenport, NY 11944 Dear Emil, Please be advised that as of today, STAT Fire Suppression, Inc., has hydrostatically tested the Apartment Buildings & Parking Garage for 200lbs at two hours at the above referenced project as requested by E & F Walsh Building Company, LLC. STAT Fire Suppression, Inc. has designed and installed the Fire Sprinkler System in accordance with NFPA #13R and local authority codes. At this time STAT Fire Suppression, Inc., has found the system to be in satisfactory condition and free of leaks. STAT Fire Suppression, Inc., will not be held responsible for any damage done in these areas. Any questions please do not hesitate to contact my office at the above referenced number. Respectfully, Pro' Profe~ CC: File AUG O1 2002 T'~ld 10,.9 AM GORDON L B8/0~/~00~ 10:12 2123853740 NY BY THiS CEI:tT~,FICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS i~URF..AU OF ELI~CTI~.ICITY ' 40 FULTON STREET ~ NEW YORK, NY 1OO38 CE.~'.TIFIES ] HAT Upon the application of upon premises owned by GORDON L, SEAMAN, INC- 630 dohnson Avenue, Ste.#201 Bohemia, NEW YORK 11716-2618, ~plieetlen Numbe~. 1063270 Section; Block: Described as a Comm~¢ial 1205 MAIN STREET SOUTHOLD, NY 11971 Lot: "PECONIC LANDING APARTMENT8 1205 MAIN STREET $OUTHOLD, NY 1 lg71 Catificate Numl~w: 1063270 Building Permit; BBC: NS11 occupancy, wherein the premises electrical system consist{rig of electrical devices and wiring, described betoW, locate0 in/on the premises au Basement, l=i~t l~l~r, Seeolxd ~oO£, Th{t~ Floor, 139 loots., Aitach~xl Garage, Outsid~, was inspected in accordance with the National Electrical Code and the detail of the nstallabon,' as 5et forth below wes found to be in compliance therewith on the Addtttottat Cbar~es L4I,-"F" 345 ~ Wa~ Hca~ Bxhaust ~ela Dayof AHy, 200a. 110 139 278 Ca,boo Mo~oxl~le Smoke 14l 0 Gas · !.O 4o H.P, 3 o 15 H,P. 6 0 -5 KW 4 0 1 H.F, 2. O ,5 Kw 1,41O 2 H.P. 2 800 19 'fhi$ certificate may not be altered in any way and is validated only by the pre~nce of a raised seat at. ',he [ocatior~ indicated. BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD Of FIRE UNDERWRITERS BUREAU Of ELECTRICITY 40 FULTON STREET - NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by GORDON I. SEAMAN, INC. * PECONIC LANDING APARTMENTS 630 Johnson Avenue, Ste.#201 1205 MAIN STREET Bohemia, NEW YORK 11716-2618, SOUTHOLD, NY 11971 Located at 1205 MAIN STREET SOUTHOLD, NY 11971 Application Number: 1063270 Certificate Number: 1063270 Section: Block: Lot: Building Permit: BDC: NS11 Described as a Commercial occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Second Floor, Third Floor, 139 apts., Attached Garage, Outside, was inspected in accordance wkh the Nadonal Flectrical Code and the detail of the insta,ation, as set forth below, was found to be in compliance therewith on the llth Day of July, 2002. Name QTY Rate Ratin~ Circuit Type I 600 i5 1 600 17 1 600 11 I 400 4 1 400 1 225 36 1 225 39 I 225 30 1 225 22 140 100 24 1 100 19 Wiring and Devices Fixture 2,033 0 Incandescent Fixture 623 0 Fluorescent Switch 3,168 0 General Purpose Receptacle 3,964 0 General Purpose Dimmers 140 0 seal Receptacle 140 0 30 amp Dryer Continued on Next Page 2 of 3 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORk BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET - NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by GORDON I. SEAMAN, INC. 630 Johnson Avenue, Ste.#201 Bohemia, NEW YORK 11716-2618, Located at Application Number: 1063270 Section: Block: Described as a Commercial 1205 MAIN STREET SOUTHOLD, NY 11971 Lot: PECONIC LANDING APARTMENTS 205 MAIN STREET SOUTHOLD, NY 11971 Certificate Number: 1063270 Building Permit: BDC: NS11 occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Second Floor, Third Floor, 139 apts., Attached Garage, Outside, was inspected in accordance with the National Electrical Code and the detail of the installation, as set forLh below, was found to be in compliance therewith on the llth Day of July, 2002. Name OTY Rate Ratin~ Circuit Type Receptacle 140 0 50 amp Range Receptacle 1,112 0 GFCI Service 3 Phase 4W Service Rating 6300 Ampere Service Disconnect: i 2000 cb Service Disconnect: 1 2500 cb Service Disconnect: 1 1800 cb Meters: 1 seal 3 of 3 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated.