Loading...
HomeMy WebLinkAbout27040-Z Apt 143FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No Z-28685 Date AUGUST 16, 2002 THIS CERTIFIES that the building MULTIPLE RESIDENCE Location of Property 100 BRECKNOCK ROAD-APT ~143 House No. Street County Tax Map No. 1000 Section 35 Block i Lot 25 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated DECEMBER 21, 2000 pursuant to which GREENPORT, N.Y. Hamlet Building Permit No. 27040-Z dated FEBRUARY 2, 2001 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is APT #143 -MULTIPLE RESIDENCE-UNIT PLAN A AS APPLIED FOR. The certificate is issued to PECONIC LANDING AT SOUTHOLD, INC. (owners) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL CIO-97-11 - JUNE 2i, 2002 UNDERWRITERS CERTIFICATE NO. 1063270 JULY ii, 2002 PLUMBERS CERTIFICATION DATED JUNE 14, 2002 - HARDY PLUMBING & HEATING Buil~'Fng InspectF~r Rev. 1/81 Form No. 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or mk and submitted to the Building Department with the following: A. For new building or new nsc: 1. Final survey of properly with accurate location of all bnildings, property lines, streets, and unusual nstural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerageqlisposal (S-9 form). 3. Appro4al of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,.multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and a consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy - New dwelling $25.00, Additions to dwelling $25.00, Alterations to dwelling $25.00, Swimming pool $25.00, Accessory building $25.00, Additions to accessory building $25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-erdating Building - $100.00 3. Photocopy of Certificate of Occupancy - $ 0.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate ofOceupancy - Residential $15.00, Commercial $15.00 . Old or Pre-existing Building: New Construction: L0~ation of_Property: Street Owner or Owners of Property: c'~C..$rl4 Suffolk County Tax Map No 1000, Section Subdivision Date of Permit. '7' b' t. Permit No. Health Dept. Approval: Planning Board Approval: Request for: Temporary Certificate Fee Submitted: $ ,~ '~ Date. (check one) Block Hamlet Filed Map. Lot: Applicant: Underwriters Approval: Final Certificate: ~ (check one) C'o ~:; ~.~ ~ ~- 5 Applicant SignatureD0nnis bi, Wilhelm ARCHITECTURE ENGINEERING PLANNING OUR CLIENTS' SUCCESS August 6, 2002 Attn: Michael J. Verity Town of Southold - Building Code Enforcement 53095 Main Road P.O. Box 1179 Southold, NY 11971-1179 Re: Mechanical & Electrical Certification PECONIC LANDING APT BLDG & COMMUNITY CENTER Long Island, New York 2000/473.00, 2000/474.00 Dear Michael: Becket Morgan Group, Inc. certifies that on June 12t~, 13th, 25th & 26th we conducted on- site visits & observed construction of the Community Center and the Apartment Building and found, to the best of our lmowledge, information and belief, construction consistent with the intent of the mechanical design documents and codes, laws and ordinances applicable at the time of design. Our certification is limited to observations recorded on these dates. Becket Morgan Group, Inc. has not provided regnlar or comprehensive on-site construction observations. Construction has deviated from the design documents, most notable in the conversion of the closed-loop heat pump system to a geothermal system. However, the conversion to a geothermal system and other observed deviations are consistent within the design intent established by Becker Morgan Group, Inc.'s design documents. The Health Center facilities have not been reviewed. If you should have any questions or require additional information, please contact our office. Sincerely, soum~,~K omcE P,x< · o7 ^ sr~r BE~,JC~R MORGAN GROUP, INC. 738 SOLrDq GOVEPdqORS AVE. lor, P DOVE~ DELAWARE 19904 302.734.7950 FAX 302.734.7965 PORT EXCHANGE SUITE 300 312 WEST MAIN SE Vice President GRT/jcr cc: Bob Ellis Jeff Vaughan 200047300af-ltr.doc FINAL INSPECTION REPORT Sidney B. Bowne & Son Consulting Engineers 235 E. Jericho Tpke., Mineola, NY 11501 PECONIC LANDING TOWN OF SOUTHOLD APARTMENT BUILDING PERMIT NO.: 27040 Z UNIT NO.: In accordance with the Agreement between the Town of Southold and Sidney B. Bowne & Son, LLP, Consulting Engineers, dated January 14, 2000, for professional engineering services relating to the above project, we have completed the final inspection for the subject premises. In addition, we have reviewed inspection reports and other relevant material for conformance to the requirements of the Town Building Department for a Certificate of Occupancy. Based on this review, we have no objection to the issuance of a Certificate of Occupancy for the subject unit. Gino N. A~lo, P.E. BARTON&AssoCIATES A R C H 1 T E C T S · P L A N N E R S / --------. August 2, 2002 Mr. Michael J. Verity Code Enforcement Officer Southold Town Hall 53095 Main Road P.O. Box 1179 Southold, NY 11971-1179 PECONIC LANDING PROJECTS. Re: Apartment Unit #143, Code Certification. Dear Mike: In reference to the above-mentioned project we, Barton & Associates, (Architects of Record for said Project), hereby certify that to the best of our knowledge, information and belief that Apartment Unit #143 has been constructed in compliance with all applicable laws, codes and ordinances. 700 E. Main Street, 3rd Floor Notristown, PA 194(}1 4102 p 610.930.2800 f 610.930.2808 Very truly your; BARTON & ASSOCIATES, LP Frank P. Laughlin, RA Senior Vice President Dennis M. Wilhelm, RLS Al Broszeit, E&F Walsh Bob Ellis, O/N Ru~ 05 02 OB:56a tx blall, 53 P.O. B o16, N~w ' n p.1 Pg, GF 82 RECEIVED Fax (631) 765-1823 T¢l~phonu (631) 765-180 BU1LDtNO DRPAP, TMEbr]' TOWN OF SOUTItOI~ ~ ERT .I. FICAT. I O N Build I. ead. clay I tify t' d Qle ::older us-.A iU the wat~ supply sysmm contains less than 2/10 of 1% :fo,e :¢~hi:lq _ (Plumbers Signature) HARDY PLUbIBINGf HEATING & AIR CONDITIONING, INC. RECEIVED 1654 COUNTY ROAD 39 SOUTHAbIPTON~ NY 11968 631-283-9333 TEL~ 631-204-1128 FAX 8/01/200 E & F Walsh Building Co. 1205 Main Road Greenport, NY 11944 Re: Apartment Building Peconic Landing To whom it may concern: All plumbing work installed by Hardy Plumbing in the apartment building at 1205 Main Rd in Greenport is in accordance with all state and local codes. The Town of Southold building department has inspected all work and all the plumbing has passed all required inspections. Hardy Plumbing operates under plumbing licenses #P1593. Paul S. Child can answer any questions at the above address and phone number. The job reference number is NC1924. Paul S. Child New Construction Manager 889 South 2nd Street Ronkonkoma, New York 11.779 631-981.-8000 NFPK 01-02 July 22, 2002 E & F Waist Building Company, LLC 1375 Kings Highway East Fairfield, CT 06430 RE: Peconic Landing 1205 Rt. 25 Greenport, NY 11944 Dear Emil, Please be advised that as of today, STAT Fire Suppression, Inc., has hydrostatically tested the Apartment Buildings & Parking Garage for 200lbs at two hours at the above referenced project as requested by E & F Walsh Building Company, LLC. STAT Fire Suppression, Inc. has designed and installed the Fire Sprinkler System in accordance with NFPA #13R and local authority codes. At this time STAT Fire Suppression, Inc., has found the system to be in satisfactory condition and free of leaks. STAT Fire Suppression, Inc., will not be held responsible for any damage done in these areas. Any questions please do not hesitate to contact my office at the above referenced number. CC: File tqco Fire & Security $implex6rinnell Simp/exGr/bne// LP 357 Crossways Park Drive Woodbur~, NY 1 ~ 79 7 Te/e: 5 I G-4 96.8484 Te/e: BOO- 746- 7539 Fax: 516-496-8489 ww~ simp/ex gr/nne// corn August 8, 2002 Gordon L. Seaman 630 Johnson Ave. Suite 201 Bohemia, NY 11716 Attention: Reference: Rich Barry Peconic Landing Apartment Building--Fire Alarm System Gentlemen: On 8/8/02 SimplexGrinnell did a final inspection along with a final test of the Fire Alarm System. Also all punch list items have been checked out and the System has been up and running for the owner's use. Therefore, as of 8/8/02 the warranty of the System has been instituted and will carry through 8/7/03. Sincerely, Paul Brady Professional Engineer BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD Of FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET - NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by GORDON L. SEAMAN INC. * PECONIC LANDING APARTMENTS , 630 Johnson Avenue, Ste.#201 1205 MAIN STREET Bohemia, NEW YORK 11716-2618, SOUTHOLD, NY 11971 Located at 1205 MAIN STREET SOUTHOLD, N? 11971 Application Number: 1063270 Certificate Number: 1063270 Section: Block: Lot: Building Permit: BDC: NS11 Described as a Commercial occupancy, wherein the premises electrical system consisting electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Second Floor, Third Floor, 139 apts., Attached Garage, Outside, was inspected in accordance with the National Electrical Code and the detail of the installation, as set forth below, was found to be in compliance therewith on the lZth Day of July, 2002. Nature OTY Rate Rating Circuit Type Additional Charges 141."F" air handlers 3-15 HP air handlers 217'1 KW heat vent units Alarm and Emergency Equipment  ExitLight 110 0 Appliances and Accessories 141 0 Gas Water Heater Elevator 4 0 40 H.P. Exhaust Fan 3 0 15 H.P. Electric Heater Baseboard 6 0 .5 KW Pump/Motor 4 0 1 H.P. Electric Heater Unit 2 0 .5 KW Air Conditioner 141 0 2 H.P. Panels 2 800 19 2 800 20 seal 2 800 18 Continued on Next Page 1 of 3 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. ElY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD Of FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET ~ NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by GORDON L. SEAMAN, INC. 630 Johnson Avenue, Ste.#201 Bohemia, NEW YORK 11716-2618, Located at Application Number: 1063270 Section: Block: Described as a Commercial 1205 MAIN STREET SOUTHOLD, NY 11971 Lot: * PECONIC LANDING APARTMENTS 1205 MAIN STREET SOUTHOLD, NY 11971 Certificate Number: 1063270 Building Permit: BDC: NS11 occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Second Floor, Third Floor, 139 apts., Attached Garage, Outside, was inspected in accordance with the National Electrical Code and the detail of the installation, as set forth below, was found to be in compliance therewith on the Name llth Day of July, 2002. QTY Rme R~ing Circuit Type 1 600 15 1 600 17 I 600 11 1 400 4 1 400 ~ I 225 36 i 225 39 1 225 30 i 225 22 140 100 24 1 100 19 Wiring and Devices Fixture 2,033 0 Fixture 623 0 Switch 3,168 0 Receptacle 3,964 0 Dimmers 140 0 Receptacle 140 0 Continued on Next Page Incandescent Fluorescent Generfl Purpose General Purpose 30 amp Dryer 2 of 3 seal This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET - NEW YORK, NY 10038 CERTIFIES THAT Upon the application of upon premises owned by GORDON L. SEAMAN, INC. 630 Johnson Avenue, Ste.#201 Bohemia, NEW YORK 11716-2618, Located at Application Number: 1063270 Section: Block: Described as a Commercial 1205 MAIN STREET SOU'[HOLD, NY 11971 Lot: * PECONIC LANDING APARTMENTS 1205 MAiN STREET SOUTHOLD, NY 11971 Certificate Number: 1063270 Building Permit: BDC: NS11 occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Basement, First Floor, Second Floor, Third Floor, 139 apts., Attached Garage, Outside, was inspected in accordance with the National Electrical Code and the detail of the installation, as set forth below, was found to be in compliance therewith on the llth Day of July, 2002. Name OTY Rate Ratine Circuit Type Receptacle 140 0 50 amp Range Receptacle 1,112 0 GFCI Service 3 Phase 4W Service Rating 6300 Ampere Service Disconnect: i 2000 cb Service Disconnect: 1 2500 cb Service Disconnect: I 1800 cb Meters: 1 seal 3 of 3 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated.