HomeMy WebLinkAbout46943-Z NOTES As s`soyT- '4 1 NO SOIL SURCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION AT THE SHALLOW EN P,OR 6 FEETOF EXCAVATION AT THE DEEP END O 2 THIS POOL MEETS THE REQUIREMENTS OF AN5I/AP5P/ICC-5 AMERICAN NATIONAL STANDARD FOR RESIDENTIAL INGROUND 5WIMMING 10" 44' 10" POOL5"AND1996BOCA CODE-SECTION 421 DIVING EQUIPMENT 15NOTALLOWED 06- 3 3 5WIMMINGPOOLSHALLBECOMPLEfELYANDCONTINUOUSLYSURROUNDEDWITHABARRIERCONSTRUCTEDIAWREQUIREMENTSOF o? SECTION R326 4 21 THROUGH 8326 4 2 6 OF THE NEW YORK STATE RESIDENTIAL CODE(2020)AN 1)IN CONFORMITY WITH ALL SECTIONS OF THE SOUTHOLD TOWN CODE DWELLING WALL(5)MAY 5ERVEASPARTOFTHE POOL BARRIERASPEP,SECTION R32642BAND ,�j CO CONDITION(1)ARE MET.OPERABLE WINDOWS IN THE WALL(S)USED ASA BARRIER SHALL HAVE SELF LATCHING DEVICE ACCESS GATES O N s• SHALL COMPLY WITH SECTION R326 5 2 OF THE NY5 RESIDENTIAL CODE(2020)AND BE SELF CLOSING,SELF LATCHING AND BE SECURELY `- BENCH r LOCKED WHEN POOL 15 NOT IN USE OR SUPERVISED ALL GATES ARE TO OPEN AWAY FROM THE POOLAREA O d O 4 DURING CONSTRUCTION THE CONTRACTOR SHALL ERECTA TEMPORARY BARRIER AROUND THE EXCAVATION IAW THE CODE OF THE V 3 TOWN OFSOUTHOLD. _ZQZ 5 POOL MUST BE EQUIPPED WITH AN APPROVED POOL ALARM CAPABLE OFDETECTING ENTRY INTO THE WATERAND SOUNDING AN Ln� b A 3'6" N a-o" AUDIBLE ALARM UPON DETECTION THATISAUDIBLEATPOOLSIDEANDINSIDETHEDWELLING THEALARMMU5TBEIN5TALLED, N __ Hzo Hzo t MAINTAINED AND USED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS THE ALARM MUST MEETA5TM F2208 C O "STAN DARD5PECIFICATIONFOP POOL ALARMS THEP EVICE MUST OPERATE IN DEPEN PENT(NOT ATTACH ED TO OR PEDEN DENT ON)OF G p- .� PERSONS V F 6 POOL5UCTIONFITTING5(EXCEPT FOP,SURFACE SKI MMER5)MUST BEPROVIDED WITH ACOVER THAT CON FORMSTOA5ME/ANSI N �°C Q A112198MORA MINIMUM IB'x23'DRAINGRATE ORA CHANNEL DRAIN SYSTEM POOL CIRCULATION SYSTEM MUSTBE EQUIPPED WITH :t o ATMOSPHERIC VACUUM RELI EF IN THE EVENT THE GRATE COVERS LOCATED WITHIN THE POOL BECOME MISSING OR BROKEN SUCH VACUUM RELIEF SYSTEMS SHALL CONFORM WITH A5ME A1121917 OR BEA GRAVITY SYSTEM APPROVED BY THE TOWN OF 50UTHOLP POOL SHALL BE PROVIDED WITH AMINIMUM OF2SUCTION FITTINGS OFTHE ABOVE MENTIONEDTYPE THE5UCTIONFITTING55HALLBE SEPARATED BY MINIMUM OF3'AND MUST BE PIPED SUCH THAT WATER 15 DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A tLA VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS) VACUUM/PRESSURE CLEANING FITTINGS SHALL BE IN AN ACCE551BLE POSITION,MINIMUM OF6"AND NO GREATER THAN 12"BELOW THE MINIMUM OPERATIONAL WATER LEVEL OR BEAN ATTACHMENTTO NTS THE SKIMMER/SKIMMERS A REQUIRED POOL ATMOSPHERIC VACUUM RELIEF SYSTEM SHALL BE INSTALLED AS PER NYS RE5IDENTIALCODE 8326 6 3(2020)AND IN ACCORDANCE WITH TOWN CODE QJ 20'VINYL COVERED STEPS 7 ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC)PRINCIPALLY ARTICLE 680 AND THE NYS V RE5IDENTIALCOpE5ECTION542011NROVGH4206 ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND QJ BE PROTECTED BY GROVND FAULT CURRENT INTERRUPTER(GFCI)CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THOSE o PROVI DING POWER TO POOL LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E42035 ALL m METAL ENCLOSURES,FENCES OR RAILINGS NEAR OR ADJACENT TO THE SWIMMING POOL THAT MAY BECOME ELECTRICALLY CHARGED QJ DUE TO CONTACT WITH AN ELECTRICAL CIRCUIT SHALL BE EFFECTIVELY GROUNDED N 2"T04"5AND BOTTOM Vl � Ln,3 8 WATER SOURCE FILLING THE POOL SHALL BE EQUIPPED WITH A BACKFLOW PROTECTION DEVICE IAW NY5 PLUMBING CODE 608 ti V Ln 9 ALL PIPING 15 DIAGRAMMATIC UNLE55 OTHERWISE STATED 0Q } 0 _" v Z 10 WALKS IF PROVIDED SHALL BE NONSLIP AND SLOPEAWAY FROM POOL EDGE .4 SECTION A 11 A MEANS OF EGRESS FOR DEEP AND SHALLOW ENDS MUST BE PROVIDED IAW AN5I/AP5P/ICC-5 SECTION 6v 0 QJ w NTS O O WATER LINE F WALL r 5E TOP O 12 CONTRACTOR TO PLACE THE POOL IAW TOWN OF 50UTHOLD CODE SETBACKS d 13 ALL DRAINAGE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY _ 4 12' 41 7 15 THE DESIGN 15 BASED ON A DRAINAGE SOIL WITH<10%SILT GROUND WATER SHALL NOT EXIST WITHIN THE EXCAVATION IF GROUND WATER EXISTS WITHIN 6'-0"FROM GRADE,DEWATERING FACILITIES WILL BE REQUIRED N m M 16 ALL GAS AND OIL HEATERS(IFIN5TALLED)FOP,THE INGkOUNP SWIMMING POOLSHALL BE NATIONAL APPLIANCE ENERGY CONSERVATION ACT(NAECA)COMPLIANT POOL HEATERS SHALL BE TESTED IAW ANSI 22156 AND SHALL BE INSTALLED IAW O` MANUFACTURERS SPECIFICATIONS OIL FIRED POOL HEATERS SHALL BE TESTED IAW UL726 POOL HEATERS SHALL BE LOCATED OR GUARDED TO PROTECTAGAINSTACCI DENTAL CONTACT OF HOT SURFACES BY PERSONS POOL HEATERS SHALL BEPROVIPEI)WITH TEMPERATURE AND PRESSURE-RELIEF VALVES FOR HEATERS NOT PROVIDED WITH AN INTEGRAL BYPASS SYSTEM A BYPASS LINE SHALL BE 5ECTION B INSTALLED FROM INLET TO OUTLETTO ADJUST WATER FLOW THROUGH THE HEATER POOL HEATERS SHALL BE PROVIDED WITH THE FOLLOWING ENERGY CONSERVATION MEASURES 4 N.TS 161 AT LEAST ONETHERMOSTATSHALL BEPROVIDEP FOR EACH HEAT]NGSYSTEM 00 162 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASYACCE55 TO ALLOW 5HUTTIN G OFF TH E OPERATION OF THE HEATER WITHOUT AD/USTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RELIGHTING THE O PILOTLIGHT M CHECK VALVE 16 3 HEATED S WIMMING POOLS SHALL BE EQUIPPED WITH A POOL COVER(EXEMPTED FROM THI5 REQUIREMENTARE OUTDOOR POOLS W COPING AND WALKWAY 101, DERIVING 20%OF THE ENERGY FORHEATING FROM RENEWABLESOURCE5AS COMPUTED OVERAN OPERATINGSEASON) W jtis-N 01 a PUMP FROM SKIMMER GRADE 16 4 TIME CLOCKS SHALL BE INSTALLED SO THE PUMP CAN BE TO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS AND CAN BESET W Q 00 co uaf O OWATER LINE y TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POOL WATER IN A CLEAN AND SANITARY CONDITION IAW APPLICABLE Z }oqq a _ SANITARY CODE OF NEW YORK STATE ��p, O Z c0 cD ,o TO DII OSAU Vy ?� A^^ a DRY,LL UNDISTURBED EARTH 17 THIS DRAWING IS FOR STRUCTURAL SHELL ONLY.ALL ACCESSORIES AND APPURTENANCES ARE DEFINED BY OTHERS z M Y M m Ud `� • 3500 PSI POURED CONC a• 18. BACKFILL W TH CLEAN EARTI-,FREE OF ROOT5 AND DEBRIS. DO NOT ALLOW THE HEIGHT OF BACKFIILL TO EXCEED THE HEIGHT OF THE n c`�`�'aGi O DIVERTER O < WATER IN THE POOL BY MORE THAN 8",OR THE WATER TO EXCEED BACKFILL BY MORE THAN B" N Y u X v all VALVE 3/e"REBAR 2)TYP d 41 [� I Opti a �, VINYL LINER • i 19 PLACE CONCRETE ON SANDY TO LOAM SOIL REMOVEANY CLAY DEPOSITANDREPLACE W/COMPACTED CLEAN BACKFILL W a U ° 2"TO 4"SAND a FILTER ZO THERE 15 NO MAIN DRAIN IN THIS POOL SUCTION FOR POOL WATER CIRCULA710N IS PROVIDED BY 1liE SKIMMERS ONLY THIS MEETS w REQUIREMENTS OF THE NYS RESIDENTIAL CODE-SECTION R326 5 FOR ENTRAPMENT PROTECTIONO F N E 21 THE POOL WAS DESIGNED IAW THE FOLLOWING- RETURNS �� ��R T HSM 21.1 THE NEW YORK STATE RESIDENTIAL CODE-SECTION 8326(2020) ro CHECK VALVE VERTICAL 3/8"REBAR 03'0C213 Q �yi 212 THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE-SECTION P40310(2020) T. 21 3 THE NEW YORK STATE FUEL GAS CODE(2020) PLUMBING SCHEMATIC (NOrSHowM 214 THE NEW YORK STATE SANITARY CODE 215 ANSI/AP5P/ICC-5 STANDARD FOR RESIDENTIAL IN-GROUND SWIMMING POOLS, T— If t I N.TS WALL SECTION 1 216 BOCA COPE-5ECTION 421 Lu 217 OPEOFTHE TOWNOF OUTHOLD n - F 1I N T.S ,l gn,- � 22 ALL BACKWASH TO BESELF-CONTAINED ON-SITE 23 POOL TO BE EQUIPPED WITH AN AUTOMATIC POOL COVERO 088415 OnT ' �FESSIoN