Loading...
HomeMy WebLinkAbout46914-Z 4 a NOTES / 1. NO SOIL SURCHARGE PERMITTED WITHIN 4 FEET OF EXCAVATION AT THE SHALLOW END,OR 6 FEET OF EXCAVATION AT THE DEEP END 0 10" 10" 2 THIS POOL MEETS THE REQUIREMENTS OF AN51/APSP/ICC-5 AMERICAN NATIONAL STANDARD FOR RESIDENTIAL INGROVND SWIMMING �. 40' POOLS"AND 1396 BOCA CODE-SECTION 421.DIVING EQUIPMENT 15 NOTALLOWED. Q o 3 SWIMMING POOL SHALL BE COMPLETELY AND CONTINUOUSLY SURROUNDED WITH A BARRIER CONSTRUCTED LAW REQUIREMENTS OF C�k' SECTION 8326 4 21 THROUGH f326 4 2.6 OF THE NEW YORK STATE RESIDENTIAL CODE(2020)AND INCONFORMITY WITH ALL SECTIONSsENCH ,7 OF THE SOUTHOLD TOWN CODE DWELLING WALL(5)MAY SERVE AS PART OF THE POOL BARRIER AS PER SECTION R326 4 2 8 AND CONDITION(1)ARE MET OPERABLE WINDOWS IN THE WALL(S)USED ASA BARRIER SHALL HAVE SELF LATCHING DEVICE ACCESS GATES _I t00 SHALL COMPLY WITH SECTION 8326 5 2 OF THE NY5 RESIDENTIAL CODE(2020)AND BE SELF CLOSING,SELF LATCHING AND BE SECURELY O I\ LOCKED WHEN POOL 15 NOT IN USE OR SUPERVISED ALL GATES ARE TO OPEN AWAY FROM THE POOL AREA O IF-C)" s'_b• SVNDECK 4 DURING CONSTRUCTION THE CONTRACTOR SHALL ERECTA TEMPORARY BARRIERAROUND THE EXCAVATION IAW THE CODE OFTHE cL } A H2O H2O O TOWN OF SOUTHOLD. V a U 5 POOL MUST BE EQUIPPED WITHANAPPROVED FOOL ALARM CAPABLE OFDEFECTLNGENTRY INTO THE WATERANDSOUNDING AN _z QZ AUDIBLE ALARM UPON DETECTION THAT 15AVPIBLEATPOOISLGEAND INSIDE THE DWELLING THE ALARM MUST BE INSTALLED, ][ ry MAINTAINED AND USED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS THE ALARM MUST MEETAS,TM F2208 v a "STANDARD SPECIFICATION FOP,POOLALARM5 THE DEVICE MVSTOPERATEINDEPENDENT(NOTA,TTACHEDTOORDEPENDENTON)OF Ed PERSONS 0 o u 6, POOLSUCTION FITTINGS(EXCEPT FOR SVR FACE SKIMMERS)MUST BE PROVIDED WITH A COVER THATCONFORMS TO ASME/ANSI V) �C4 g PLAN A11219 BM ORA MINIMUM 18"x 23"DRAIN GRAFE ORA CHANNEL DRAIN SYSTEM. POOL CIRCULATION SYSTEM MUST BE EQUIPPED WITH ATMOSPHERIC VACUUM RELIEF IN THE EVENT THE GRATE COVERS LOCATED WITHIN THE POOL BECOME MISSING OR BROKEN SUCH VACUUM RELIEF SYSTEMS SHALL CONFORM WITH ASME A1121917 OR BEA GRAVITY SYSTEM APPROVED BY THE TOWN OF SOUTHOLD NTS POOL SHALL BE PROVIDED WITH AMINIMUM OF2SUCTION FITTINGS OFTHE ABOVE MENTIONED TYPE THE SUCTION FITTINGS SHALL BE SEPARATED BY A MINIMUM OF3'AND MUST BE DIPED SUCH THAT WATER 15 DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A VACUUM RELIEF-PROTECTED LINE TO THE PUMP(OR PUMPS) VACUUM/PRESSURE CLEANING FrMINGS SHALL BE IN AN ACCESSIBLE 20'VINYL COVERED STEPS SVNDECK POSITION,MINIMUM OF 6"AND NO GREATER THAN 12'BELOW TH E MINIMUM OPERATIONAL WATER LEVEL OR BE AN ATTACHMENT TO THE SKIMMEWSKIMMERS.A REDUIRED POOL ATMOSPHERIC VACUUM RELIEF 5YSTEM SHALL BE INSTALLED AS PER NYS RE5IDENTIALCODE 8326 6 3(2020)AND IN ACCORDANCE WITH TOWN CODE Ql V _ 7 ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 70(NEC)PRINCIPALLY ARTICLE 680 AND THE NY5 S; S M ^' RESIDENTIAL CODE SECTIONS 4201 THROUGH 4206 ALL ELECTRICAL DEVICES MUST BE APPROVED BY UNDERWRITERS LABORATORIES AND "C3 Z. �z°Toa^SAND BcrroM BE PROTECTED BY A GROUND FAULT CURRENT INTERRUPTER(GFC0 CURRENT CARRYING ELECTRICAL CONDUCTORS EXCEPT FOR THO SE V) 'y PROVIDING POWER TO POOL LIGHTING AND POOL EQUIPMENT SHALL MEET THE SEPARATION REQUIREMENTS OF TABLE E42035 ALL Q) METAL ENCLOSURES,FENCES OR RAILINGS NEAR OR ADJACENT TO THE SWIMMING POOL THAT MAY BECOME ELECTIRICALLY CHARGED CL DUE TO CONTACT WITH AN EL-CTP ICAL CIRCUITSHALL BE EFFECTIVELY GROUNDED SECTION A 8. WATER SOURCE FILLING THE POOL SHALL BE EQUIPPED WITH A BACKFLOW PROTECTION DEVICE IAW NYS PLUMBING CODE 608 110- i V o } N.TS 9. ALLPIPINGISDIAGRAMMATICUNLE55OTHERWHSESTATED. s z WATER LINESOP OF WALL l- O V C v 10 WALKS IF PROVIDED SHALL BE NONSLIPAND SLOPE AWAY FROM POOL EDGE 4' iZ' 4' v O 11. A MEANS OF EGRESS FOR DEEPAND SHALLOW ENDS MUSTBE PROVIDED IAW ANSI/APSP/ICC-5 SECTION 6 S C S O 4 12 CONTRACTOR TO PLACE THE POOL IAW TOWN OF SOUTHOLD CODE SETBACKS. ~ Lnw 13 ALL DRAINACE FROM THE POOL SHALL BE MAINTAINED ON THE SUBJECT PROPERTY 15 THE DESIGN 15 BASED ONADRAINAGE501LWIT-1<10%SILT GRCUNDWATER SHALL NOT EXI5TWITHINTHE EXCAVATION. IFGROUND WATER EXISTS WITHIN 6'-O"FROM GRADE,DEWATERING FACILITILES WILL BE REQUIRED. p SECTION B 16 ALL GAS ANDOIL HEATERS OFINSTALLED)FOR FHE INGROUND 5WIMMING POOL SHALL BE NATIONAL APPLIANCE ENERGY Ol N T 5 CONSERVATION ACT(NAECA)COMPLIANT. PCOL HEATERS SHALL BE TESTED IAW ANSI 72156 AND SHALL BE INSTALLED IAW MANUFACTURERS SPECIFICATIONS OIL FIRED POOL HEATERS SHALL BE TESTED IAW UL726 POOL HEATERS SHALL BE LOCATED OR GUARDED TO PROTECTAGAINSTACCIDENTAL CONTACT OF HOT SURFACES BY PERSONS POOL HEATERS SHALL BE PROVIDED WITH TEMPERATURE AND PRESSURE-RELIEF VALVES, FOR HEATERS NOT PROVIDED WITH AN INTEGRAL BYPASS SYSTEM A BYPASS LINE SHALL BE Id 2 2 INSTALLED FROM INLET TO OUTLET TO ADJUST WATER FLOW THROUGH THE HEATER POOL HEATER55HALL BE PROVIDED WITH THE Q y CAND WALKWAY 10> C HECK VALVE FOLLOWING ENERGY CONSERVATION MEASURES 00 MYOTH 00 (BY OTHERS) �n O PUMP FROM SKIMMER GRAPE 161 AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR EACH HEATING SYSTEM �! CD WATER LINE 162 ALL POOL HEATERS SHALL BE EQUIPPED WITH AN ON-OFF SWITCH MOUNTED FOR EASY ACCESS TOALLOW SHUTTING OFF THE z TO OPERATION OFTHEHEATER WITHOUT AP)USTNGTHE THER.M05TAT5ETnNGANDTOALLOWRESTARTINGWITHOUT RELIGHTING THE �, 0 DRYWELL PILOT LIGHT DRYWELL� UNDISTURBED EARTH 163 HEATED SWIMMING POOLS SHALL BE EQUIPPED NITH A POOL COVER(EXEMPTED FROM THIS REQVI REMENTARE OUTDOOR POOLS w >r--N d • 5500 PSI POURED CONG a� DERIVING 2090E THE ENERGY FOR HEATING FROM RENEWABLE SOURCES AS COMPUTED OVER AN OPERATING SEASON) DIVERTER m 00 164 TIME CLOCKS SHALL BE INSTAL-EP SO THE PUMP CAN BE SET TO RUN DURING OFF-PEAK ELECTRICAL DEMAND PERIODS AND CAN BESETCc 3/8'REBAR 21 NP "+ C .D VALVE O TO RUN THE MINIMUM TIME NECESSARY TO MAINTAIN THE POC'L WATER IN A CLEAN AND SANITFARY CONDITION IIAW APPLICABLE ('J 3 VINYL LINER • SANITARY CODE OF NEW YORK STATE y = m U d iIs�.� cz z'TO 4"SAN0 �� 17 THIS DRAWING LS FOR STRUCTURAL SHELL ONLY ALL ACCESSORIES AND APPURTENANCES ARE DEFINED BY OTHERS Lu C�. a 0 FILTER N Y X Sr' 18 BACKFILL WITH CLEAN EARTH,FREE OF ROOTS AND DEBRIS DO NOT ALLOW THE HEIGHT OF BACKIFILL TO EXCEED TIHE HEIGHTOF THE -H 2 h w \ \ \ \ WATER IN THE POOL BY MORE THAN B", OR THE WATER TO EXCEED BACKFILL BY MORE THAN 8" (��I ►a a> TO RETURNS W 0 19. PLACE CONCRETE ON SANDY TO LOAM SOIL. REMOVE ANY CLAY DEPOSITAND REPLACE W/COMPACTED CLEAN BACKFILL V CHECK VALVE (NVERTICALSHOW'REBAR©3'OC. 20 THERE L5 NO MAIN DRAIN IN THIS POOL.SUCTION FOR POOL WATER CIRCULATION I5 PROV D D Y I 5-K1M ERS '^-��tfH 51M15E - PLUMBING SCHEMATIC cNorsHowN) REQUIREMENTS OF THE NYS RESIDENTIAL CODE-SECTION R326 5 FOR ENTRAPMENT PROTE r- \ .� I r' I r i QF N E w }'O N.T.S. WALL SECTION 21 THE POOL WAS DESIGNED IAW THE FOLLOWING. V 11 t 'THOAf i N T.5 21,1. THE NEW YORK STATE RESIDENTIALCODE-SECTION 8326(2020) ,1 221 OQJM1 212 THE NEW YORK STATE ENERCY CONSERVATION CONSTRUCTION CODE-SECTION R403.10(2 0) S E f 2 O G 213, THE NEW YORK STATE FUEL GAS CODE(2020) (rj � = (� y c(_ 21,4. THE NEW YORK STATE SANITARY CODE tq� Lu 215 AN51/APSP/ICC-5 STANDARD FOR RESIDENTIAL IN-GROVNDSWIMMING POOLS 1 Lu 216. BOCA CODE-SECTION 421 15-fir n r 217. CODE OF THE TOWN OF SOUTHOLD. -^- 7— 22, ALL BACKWASH TO BE SELF-CONTAINED ON-SATE. s S� 088415 OFESS\0 I -