Loading...
HomeMy WebLinkAbout46511-Z �o�gHFfO( Town of Southold 9/19/2021 P.O.Box 1179 0 o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42352 Date: 9/19/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 340 Birch Dr.,Laurel SCTM#: 473889 Sec/Block/Lot: 128.4-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/22/2021 pursuant to which Building Permit No. 46511 dated 6/29/2021 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Kermer,Nicholas&Ruchman,Rebecca of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46511 8/18/2021 PLUMBERS CERTIFICATION DATED l A ori e i ature �oFFot� � TOWN OF SOUTHOLD ay BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy�o ac�u SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46511 Date: 6/29/2021 Permission is hereby granted to: Kerzner, Nicholas 340 Birch Dr Laurel, NY 11948 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 340 Birch Dr., Laurel SCTM # 473889 Sec/Block/Lot# 128.4-7 Pursuant to application dated 6/22/2021 and approved by the Building Inspector. To expire on 12/29/2022. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 B ilding nspector oF soUP�®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road ir Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 • �o sear.devlinr'cr�town.southold.ny.us �yc®UNTI,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Nicholas Kerzner Address: 340 Birch Dr city Laurel st: NY zip: 11948 Building Permit* 46511 section: 128 Block: 1 Lot 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Element Energy License No: 52689ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Solar X Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Surrey Roof X Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 11.89kW Roof Mounted PV Solar Energy System w/ (29)LG410N2W-V5 Panels, Enphase IQ3 Combiner w/ 220x2, AC Disconnect/ Rapid Shutdown Notes: Solar Inspector Signature: Date: August 18, 2021 S.Devlin-Cert Electrical Compliance Form �a04S0U1y0 ��� •C43 d � I� - -- # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] , FOUNDATION 1 ST = [ ° ] ROUGH PLBG. [ ] FOUNDATION 2ND = - [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL f ] FIREPLACE & CHIMNEY [ ] ,FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [lp LECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: Lw� 6,q o 12, e-- y' DATE �/ INSPECTOR OE SOUTyo� I 3q � —� # # TOWN OF SOUTHOLD BUILDING POPT. couer+, 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE ��� 'l �I INSPECTOR l �o��pF SOUIyo� # # TOWN OF SOUTHOLD'BUILDING DEPT. o`yrou�m 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ]- FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL SO4%0"" [ ] FIREPLACE & CHIMNEY [° ] FIRE,SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: _ DATE °[ INSPECTOR FIELD-INSPECTION REPORTDATE Cq� Tg. FOVN ATION(1ST) ~ FOUNDATION(2ND) rCn ROUG. IFRAMING& .� PI,,UMMING y 1 tNSL7,ALTION PER N..Y. y STATE ENERGY CODE hv- .�a► Vil. 7 _ �nvAL , z �• _� Zoho Sign Document ID AAHNUKYIURN4UH7PTUUHKM06XKNZXX92TUR285ZVXSK QFfO(rcOG TOWN OF SOUTHOLD —BUILDING DEPARTMENT y2 y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold, NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownn�gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only nDD V PERMIT NO. Building Inspector: JUN 2 2 2021 Applicatioris,and'forms"must,be filled-out in•their entirety. Incomplete s applications will riot be,accep1 .ted."Where the"Applicant isnot t6-owner,an ,�JD,Dg G DEPT. Owrier's'Authoirizatiowform(Page Y2)shall be completed'.,_ T �;�Q,T ✓g:�'/-AT ,IOLP- Date:6/22/21 OWNER(S)OF PROPERTY: Name:Nicholas Kerzner scTM#1000-128000100007000 Project Address:340 Birch Drive, Laurel, NY 11948 Phone#:(631_) 806-0123_ TFmail:permits@e2sys.com Mailing Address:34.O Birch Drive, Laurel, NY 11948 CONTACT PERSON: r _ Name:Danielle Rodger Mailing Address:7470 Sound Ave MattituCk NY 11952 Phone#:631 716 5003 Email_permits@e2sy_S.COm _ DESIGN PROFESSIONAL INFORMATION: _ Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name:Element Energy_LLC Mailing Address:7470 Sound Ave MattituCk NY 11952 Phone#_631 716 5003_ Emai':permits@e2sys.com DESCRIPTION OF PROPOSED,CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: E Other Solar $42500.35 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 Zoho Sign Document ID AAHNUKYIURN4UH7PTUUHKM06XKNZXX92T(UR285ZVXSK 4 - -PROPERTY INFORMATION,; Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to Residential Zone AC this property? DYes ®No IF YES, PROVIDE A COPY. D,Ch'eck'Box'After Reading: RThe owner%ontractor/design professional is responsible for all drainage and storm water issues as`provided by Chapter 236 of the Town Code,APPLICATION IS HEREBY MADE to the Building Department for the`issuance"of a Building Permit pursuant to the Building Zone~ 'Ordinarice of the Town of Southold,Suffolk;County;New°York'and other'°applicable'laws,`Ordiriances'or Regulations,°for the'construC46wof building's',. - additions,alterations or for removal or demolition as herein described:The applicant agrees to comply with all applicable laws;ordinances,building,code;.. housing code and regulations and to.admit auihokzed inspectors on premises and in bbilding(s)for necessary inspections,.False statements made herein are p'1unishable-as-a Class A misdemearior;pursuaiit to Section 210.45 of the New;YOrk State Penalia Application Submitted By(print name):Danielle Rodger BAuthorized Agent ❑Owner Signature of Applicant: r Date: 6/22/21 STATE OF NEW YORK) SS: COUNTY OF ) Danielle Rodger being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Ae, t (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I n n day of , 20a)—/ Notary Public DEBRAASEPU2AIL � ERTY OWNER AUTHORIZATION Q1�a db3aftere the applicant is not the owner) 11'IY > 9 1- Nicholas Kerzner residing at 340 Birch Drive, Laurel, NY 11948 do hereby authorize Element Energy LLC to apply on my behalf to the Town of Southold Building Department for approval as described herein. X_j_ Jun 22 2021 15:44 EDT Owner's Signature Date Nicholas Kerzner Print Owner's Name 2 - U SUFFol a ILDING DEPARTMENT- Electric I pecjgt - 8 2021 TOWN OF SOUTHOLD Q �JUL - 8 2021 Town Hall Annex - 54375 Main Road - PO 0 =b 'DEPT. o - Southold, New York 11971-095WI'v"�OV AT'�t ® D 41 �p�.,DUTLD1 sTG DEPTgTelephone (631) 765-1802 - FAX (631) 765-9502 '�I ft-so utholdtownny.gov - sea ndP—southoldtown ny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Name: License No.: email: 2-s r r Address: Phone No.: JOB SITE INFORMATION (All Information Required) Name: Address:' 3W .e, e yj/ Cross Street: Phone No.: Bldg.Permit#: � 1 email: l f Tax Map District: 1000 Section: Block: Lot: dp 70a BRIEF DESCRIPTION OF WORK (Please Print Clearly) G���l a/,/ me //, �1�/ . 02 Ll L Circle All That Apply: Is job ready for inspection?: YES /e Rough In Final Do you heed a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 3 Ph Size: � JO -A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected- Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Formals PERMIT# Address: Switches Outlets G F I's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven W/D Smokes DW , Mini Carbon Micro Generator Combo Cooktop Transfer AC AH Hood Service Amps Have Used Special: Comments 217C) AZ'V �2Z ��� (O � � T� r NYS1F New York State Insurance Fund 8 CORPORATE CENTER DR,3RD FLR,MELVILLE, NEW YORK 11747-3129 1 nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE D D A A^AAA 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 HUNTINGTON NY 11743 OEM] SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 431321 07/13/2020 TO 07/13/2021 8/11/2020 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER. 737801881 U-26.3 Al C' ® DATE(MMYY) v CERTIFICATE OF LIABILITY INSURANCE 7/17/7/17/zo2o THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: ROBERTS FEDE INSURANCE AGENCY PHONE 63 1- - TA_x__ 631-385-1766 A/C No Ext A/C No): 23 GREEN STREET,SUITE 102 E-MAIL HUNTINGTON,NY 11743 ADDRESS: ROBERTS.FEDE INSURANCE INSURER(S)AFFORDING COVERAGE NAIC q INSURER A INSURED INSURERB:STATE INSURANCE FUND 523930 Element Energy LLC INSURERC:SHELTER POINT POINT 4 ELEMENT ENERGY SYSTEMS INSURERD: 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 INSURERF: COVERAGES CERTIFICATE NUMBER: 7,786REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR POLICY NUMBER MM/DD MM/DD COMMERCIAL GENERAL LIABILITY CL00275204 7/14/2020 7/14/2021 EACH OCCURRENCE $ 3,000,000 X X DAMAGE TO RENTED CLAIMS-MADE � OCCUR PREMISES Ea occurrence $ 100,000 A MED EXP(Any one person) $ 5000 TCF1132060001201 7/14/2020 7/14/2021 PERSONAL&ADV INJURY $ 3000000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 3,000,000 POLICY ECT LOC PRODUCTS-COMP/OP AGG $ 3000000 OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per axident UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAR CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY 124494445 STATUTE ER Y/N 7/13/2020 7/13/2021 ANY PROPRIETOR/PARTNER/EXECUTIVE E L EACH ACCIDENT $ 1,000,000 B OFFICER/MEMBER EXCLUDED? FX] NIA (Mandatory In NH) E L DISEASE-EA EMPLOYEE $ 1-000-000 If yes,describe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ 1 000 non NY State DBL DBL567527 1/01/2020 1/01/2021 Statutory DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) CERTIFICATE HOLDER IS ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Southold, NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b Business Telephone Number of Insured ELEMENT ENERGY LLC 7470 SOUND AVE MATTITUCK, NY 11952 1 c Federal Employer Identification Number of Insured Work Location Of Insured(Onlyrequiredrfcoverageisspecifically limited to or Social Security Number certain locations in New York State,i e, Wrap-Up Policy) 823336604 2 Name and Address of Entity Requesting Proof of Coverage 3a Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company TOWN OF SOUTHOLD 54375 MAIN ROAD 3b Policy Number of Entity Listed in Box"l a" SOUTHOLD NY 11971 DBL567527 3c. Policy effective period 01/01/2020 to 12/31/2021 4. Policy provides the following benefits © A Both disability and paid family leave benefits B Disability benefits only C Paid family leave benefits only 5 Policy covers• ❑X A All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law ❑ B Only the following class or classes of employer's employees Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits Insurance coverage as described above Date Signed 8/11/2020 By �Jja At (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent ofthat insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT. If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier, this certificate Is COMPLETE Mail it directly to the certificate holder If Box 413,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120 1 Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) I I I1 °1°°°1°° °°°°1°°° III I 1�1 DB 120.1 (10-17) WEOASN EDCDATE: .P:# .S/Y: NOTIFY.i,BUILDING DEPARTMENT AT 765-1602 s •8-AM:TO 4 PM FOR-THE- FOLLOWING•'INSPECTIONS: 1. FOUNDATION ;TWO REQUIRED FOR POURED CONCRETE 2. ROUGH:=-•FRAMING & PLUMBING 3. INSULATION-- 4. FINAL - CONSTRUCTION MUST' BE-COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITION OI SOUTHOLD TOWN Z SOUTHOLD T PLANNING BOAR: SOUTH TOWN TRUSTEES N . .DEC or CUPANCY OR USE IS,UNLAWFUL WITHOUT CERTIFICAT, OF OCCUPANCY ELECTRICAL INSPECTION REOUIRED Zoho Sign9Document ID JYVCT90TKDOSGQFVQX2T--5FBS5MYS2COPUCJLPJIHW t Town of Southold June 21st, 2021 Building Department Town Hall Annex 54375 Main Road P.O. Box 1179 Southold, New York 11971-0959 Subject: Roof Mounted Solar Panels at the Kerzner Residence, 340 Birch Dr. Laurel, NY 11948 To Whom It May Concern: I hereby state that it is my professional opinion that the subject plans comply with the 2020 Residential Code of New York State, the 2017 National Electric Code, ASCE 7-16, and NFPA-70. These code requirements Include the fact that the roof framing is adequate to support the additional loads from solar panels as well as roof ridge and peak access to first responders. I have evaluated the structural framing of the existing roof with the additional loading to account for the proposed solar panel application. Deflection and stresses of the structural components remain within the allowable for the existing roof for wind pressures from 130 mph, 3 second gust, Exposure B with a ground snow load of 20 pounds per square foot. Mounting locations and methods are as indicated in the submitted plans. From the site inspection and analysis, and as evidenced by previous roof loads withstood, it is my professional opinion that the existing building and roof framing is structurally adequate to support the reactions of the solar panels in addition to the existing code required for live and dead loads. Also the wind analysis concluded that the mounting system as shown on the plans is adequate to resist the calculated uplift pressure. The dead load of the heaviest solar panel assembly in this evaluation Is approximately 3.1 pounds per square foot. Please contact me if you have any questions or comments about the above. Sincerely, Gennaro Anthony Giustra P.E. OF NEIN Great Eastern Services, Inc. CO A PO Box 2401 24 Harvey Rd n w Riverhead, NY 11901 ZN ceico+ ' C� Office: 631.543.9555 r ARDF034411 P� Mobile: 631.235.0189 Email: jerrygiustra@gmail com r Zoho Sign Document ID JYVCT90TKDOSGQFVQX2T--5FBS5MYS2COPUCJLPJIHW J" COPE OF WORKr „ DESIGN*DRAPTING BY 1f q8 ELEMENT ENERGY LLC TO INSTALL A 1 1 89 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE KFRZNER RESIDENCE, REVIEW 13Y M NABCEP GER7IFIE �, T 051 1 12-129 LOCATED AT 340 B ?URCH DRIVE, LAUREL, NY 1 1948(40 9GG230, -72 545323) j/ ��' / �,gr� -�J1 -7,, THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT REVISIONS THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES 1 J/ DESCRIPTION DATE REV ` ' 25 y.. -21-2021 NEO/ ORIGINAL 06 SYSTEM RATING ��pF NE y ;� r^t, ,r\P PCO A GO,p / Cutcf o'gue 1 1.89 kW DC STCLU LLJ EQUIPMENT SUMMARY ? c ' NewSuffo�k, �r } Mattituck , , • 29 LG LG4I ON2W-V5 PV MODULES 1 = " - ``` J 6101, 03443 / _. =Sou�dAve // �r er 29 ENPHASE IQ7PLU5-72-2-U5 MICRO INVERTERS A�j P�, / ,! �- °c` CONTRACTOR I IKONRIDGE XK 100 MOUNTING SYSTEM �FESSON SHEET INDEX ,/// // f __� ELEMENT ENERGY, LLC. Northville Laurel !Robins Islann� PV-1 COVER N - �f Zoho Sign Document ID JYVCT90TKDOSGQFVQX2T--5FBS5MYS2COPUCJLPJIHW ` LEGEND CONSTRUCTION NOTES TER THE ROOF SETBACK/PATHWAY SHALL NOT BE TE DE51GN B DRAFTING BY SMAIINnSERMCE PANEL 1 .)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIRED WHEN THE OPPOSING OR ADJACENT A\ ELEMENT ENERGY LLC `v REVIEW BY J M NABCEP CERTIFIE NEW PV SUB-PANELS MANUFACTURER'S INSTALLATION INSTRUCTIONS. ROOF SLOPE 15 AN ACCESS ROOF IN ° 051 1 12-129 A/C DISCONNECT 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING ACCORDANCE WITH R324.G.I EXCEPTION OF ° IINVER�S 3 )ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 2020 NYS FIRE CODE ` Q GND ELECTRODE REVISIONS PV MODULE Dg DESCRIPTION DATE REV RACKING RAIL �N 2�°oQ 1?.°o ORIGINAL OG-21-2021 O ATTACHMENT POINT 4 '1"°o ---RAFTERS I 11-011 5'-8" 2 21°° l\a°° PROOF PITCH ANGLE S pISUNRUN METER ®VENT 0PLUMBING VENT ®SKY LIGHT ACCESS ROOF / CONTRACTOR ®CHIMNEY / ®COMPOSITE SHINGLES / GOOD CONDITION POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY ELEMENT ENERGY, LLC. 7470 SOUND AVE / 3 ML TITUCK, NY 1 1352 LICENSE #43889-H / 1 I -6.4 LICENSE # 522(59-ME woa// PROJECT NAME p2• ACCESS ROOF U LLJ OO z > �t LUCm rn 3 2'-3 I II (s) 2 OF N EI�y � U z 7U ,�P PEiO A O G/L W m 'G) G): / U I �jrG. W z / / 0 LU O Q 0 � w m z _j 10344`3 / Aj��FESSIONP\. j 14'- I 12" SHEET NAME / 51TE PLAN / DRAWING SCALE ACCESS ROOF / / 3/ 1 611 = 1 1-011 SHEET NUMBER PV-2 TAX MAP: 1 000 128000100007000 Zoho Sign Document ID JYVCT90TKDOSGQFVQX2T--5FBS5MYS2COPUCJLPJIHW LEGEND CONSTRUCTION SUMMARY CONSTRUCTION NOTES DESIGN 4 DRAFTING BY �M MAIN SERVICE PANEL (29) LG LG4 I ON2W-V5 PV MODULES I )ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE ELEMENT ENERGY LLC NEW PV SUB-PANELS (DIMENSIONS- 79.7'X 40.3"X 1 .3") WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS N REVIEW BYJ M NABCEP CERTIFIE A/C DISCONNECT (29) ENPHA5E IQ7PLU5-72-2-US MICRO INVERTERS 2 ) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH ° os 1 12-129 COMBINER MINIMUM NEMA 3R RATING. O INVERTERS (88)ATTACHMENT POINTS @ G4"O.C. MAX GND ELECTRODE (341 7) LF IRONRIDGE XR100 MOUNTING SYSTEM 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE REVISIONS PV MODULE ROOF TYPE = ASPHALT SHINGLE(TWO-LAYERS) FIELD VERIFICATION. 0 ° DESCRIPTION DATE REV RACKING RAIL oo� 120 ORIGINAL OG-21-2021 0 ATTACHMENT POINT 10 ---RAFTERS 2� 210° 1a0o PROOF PITCH ANGLE C �19SUNRUN METER •7 ®VENT311 O PLUMBING VENT 1-3-11/3� 4 ®SKY LIGHT -1 � � I II CONTRACTOR ®CHIMNEY — — ACCESS�ROOF — — — — — I O ®COMPOSITE SHINGLES —I 2 GOOD CONTIAL SHAD ELEMENT ENERGY, LLC ION POTENTIAL SHADING ISSUES — — — —I TRIM/REMOVE AS NECESSARY 7470 SOUND AVE —I MATTITUCK, NY 1 195 LICENSE #43889-H LICENSE # 526(59-ME / PROJECT NAME LU - - - - - - - — — — U LL-( - - - - - - °� - - - - - - A��� F w 0> ARRAY #2 - - - - - - - rn N - - - - - - - ARRAY # I - I I MODULES - - - - - - �� 0 - - - - 18 MODULES w = 10°PITCH I i C) n 40°PITCH U Z — — — — — — 118°AZIMUTH Cz 298°AZIMUTH F- - - - - - `- - - - - - - - ' ' m w L_Ly � 5 - - - - - - - - - - - - - - Lu �' g - -- - - - - - - - - - - -I OF NEII,Y —I P PR O A 0� SHEET NAME CIO— — — — — — - — SG�li�, �. ROOF DETAIL z �O 103445 �Ci� DRAWING SCALE - - - - - - - - - - / - - A�OPESSIONP� 3/ 16" = I '-OIL ACCESS ROOF SHEET NUMBER PV-3 TAX MAP: 1 000 128000100007000 Zoho Sign Document ID JYVCT90TKDOSGQFVQX2T--5FBS5MYS2COPUCJLPJIHW LOAD CALCULATION ARRAY#I ARRAY#2 ITEM DESCRIPTION ARRAY#I ARRAY#2 DE51GN 4 DRAFTING BY RB RiclLie Bearr✓Board 2"X 8" D. FIR RIDGE 2"X 8" D FIR RIDGE ELEMENT ENERGY LLC MODULE WEIGHT(Lbs) 448 448 R Rafters 2"X G" D FIR @ I G"O.C. 2"X G" D FIR @ I G"0 C REVIEW BY J M NABCEP CERTIFIE (D) Deckm 3/4 PLYWOOD 3/4" PLYWOOD 051112-129 #OF MODULES 18 I I (P) Pitch 40° I O° TOTAL MODULE WEIGHT(Lbs) 806 4 4928 �QF NEVV y (C) Collar Ties 2"X 4" D FIR @ I G"O.0 2"X 4" D FIR @ I G"0 C. REVISIONS TOTAL LENGTH OF RAIL(Ft) 240 6 1 O 1 1 �.�P�PFtO A G7� O� (J) Ceihn6j Joist 2"X 8" D FIR @ I G"0 C I N/A DEScRIPr10N DATE REV Horizontal Span of(R) GO" MAX 11 28" MAX ORIGINAL 06-21-2021 RAIL WEIGHT PER FOOT(Lbs) 0 68 0 68 * C7 TOTAL RAIL WEIGHT(Lbs) 163 6 68 7 e rG #OF 5TRANDOFF5 60 28 !� WEIGHT PER STRANDOFF(Lbs) 2 2 ZCP ' (RB TOTAL STANDOFF WEIGHT(Lbs) 120 56 Opp D3443 (w HEADER t� ki _ RO�SS�ONr� (D) (P) (R5 HEADER TOTAL ARRAY WEIGHT(Lbs) 10900 61 7 5 (D) POINT LOAD(Lbs) 182 22 I 1 I CONTRACTOR � I TOTAL ARRAY AREA(5cj Ft) 3497 2137 (C) I ARRAY DEAD LOAD(Lbs/Scj Ft) 3 I 29 (K) i (C) ELEMENT ENERGY, LLC WIND DESIGN SUBJECT TO DAMAGE FROM (P II 7470 SOUND AVE GROUND SEISMIC WINTER ICE BARRIER AIR MEAN MATTITUCK, NY 1 195 SNOW Speeds Topographic Special Windborne DESIGN Frost DESIGN UNDERLAYMENT FLOOD FREEZING ANNUAL I I LICENSE #43889-H LOAD' (mph) effectskwind debris CATEGORYf Weatheringa line Termite TEMPe REQUIREDh HAZARDSB INDEXI TEMPI region' zone' depthh I I LICENSE # 52G89-ME MOD TO I I 20 130 NO NO NO B SEVERE 3 FT HEAVY 15°F YES FE EA 599 51°F I MANUALJ DESIGN CRITERIA^ (H) I Winter Summer Altitude Indoor Design Heating I I Elevation Latitude heating cooling correction factor design temperature cooling temperature I I PROJECT NAME temperature difference I 108 FT 410 N 15°F 86°F 100 70°F 75°F 55°F [ARRAY#I] [ARRAY#21 Wind Wind Cooking Coincident Daily Winter Summer [l,.j temperature difference velocity velocity wet bulb range humidity humidity U Wco I heating cooling \ 11°F 15 MPH 7 5 MPH 72'F MEDIUM(M) 40% 32 GR @50%RH W / For SI 1 pound per square foot=0 0479 kPa,1 mile per hour=0 447 m/s ROOF FRAMING DETAIL 1 C) Q — a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code,the frost line depth strength n required for weathering shall govern The weathering column shall be filled In with the weathering Index,"negligible,""moderate"or"severe"for concrete as determined L^L.J/ } from Figure R301 2(4) The grade of masonry units shall be determined from ASTM C34,C55,C62,C73,C90,C129,C145,C216 or C652 L.L Q z b. Where the frost line depth requires deeper footings than Indicated In Figure R403 1(1),the frost line depth strength required for weathering shall govern The jurisdiction L� shall fill In the frost line depth column with the minimum depth of footing below finish grade W CD J C. The jurisdiction shall fill In this part of the table to Indicate the need for protection depending on whether there has been a history of local subterranean termite damage W d. The jurisdiction shall fill 1n this part of the table with the wind speed from the basic wind speed map[Figure R301 2(5)A] Wind exposure category shall be determined MODULE MOUNTING CLAMP z on a site-specific basis In accordance with Section R301 2 1 4 1�7 e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values forwinterfrom Appendix D of the Plumbing Code of New York State Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official [Also SOLAR MODULE LLJ in Q see Figure R301 2(1).] STAINLESS STEEL 3/8" f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301 2 2 1 BOLT AND NUT g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data The flood hazard map shall include,at a minimum,special flood hazard areas as Identified by the Federal Emergency Management Agency In the Flood Insurance Study for the community,as amended or revised with i The accompanying Flood Insurance Rate Map(FIRM), it Flood Boundary and Floodway Map(FBFM),and ONRIDGE ALUMINUM RAIL in Related supporting data along with any revisions thereto ALUMINUM"L"BRACKET SHEET NAME The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section h. In accordance with Sections R905 1 2,R905 4 3 1,R905 5 3 1,R905 6 3 1,R905 7 3 1 and R905 8 3 1,where there has been a history of local damage from the ALUMINUM FLASHING p effects of Ice damming,the jurisdiction shall fill In this part of the table with"YES"Otherwise,the jurisdiction shall fill in this part of the table with"NO" STI\U CTU RA I. The junsdiction shall fill In this part of the table with the 100-year retum period air freezing Index(BF-days)from Figure R403 3(2)or from the 100-year(99 percent) value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)" j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air Freezing Index-USA Method (Base 32°F)" ASPHALT SHINGLE ROOF k. In accordance with Section R301 2 1 5,where there Is local historical data documenting structural damage to buildings due to topographic wind speed-up effects,the 5/1 6"x G"5TAINLE55 jurisdiction shall fill In this part of the table with"YES"Otherwise,the jurisdiction shall Indicate"NO"In this part of the table STEEL LAG BOLT WITH DRAWING SCALE I. In accordance with Figure R301 2(5)A,where there Is local historical data documenting unusual wind conditions,the jurisdiction shall fill In this pa of the table with 2 1/2"MIN THREAD "YES"and identify any specific requirements Otherwise,the jurisdiction shall indicate"NO"in this part of the table PENETRATION SEALED AS NOTED m. In accordance with Section R301 2 1 2 the jurisdiction shall Indicate the wind-borne debris wind zone(s) Otherwise,the jurisdiction shall indicate"NO"In this part of the WITH GEOCEL 4500 table (EQUIVALENT OR BETTER) n. The jurisdiction shall fill In these sections of the table to establish the design criteria using Table 1a or ib from ACCA Manual J or established criteria determined by the jurisdiction o. The ground snow loads to be used In determining the design snow loads for roofs are given In Figure R301 2(6)for sites at elevations up to 1,000 feet Sites at elevations above 1,000 feet shall have their ground snow load Increased from the mapped value by 2 psf for every 100 feet above 1,000 feet SHEET NUMBER (') See Figure R301 2(4)B PV-4 TAX MAP: 1 000 128000100007000 MOUNTING DETAIL I Zoho Sign Document ID JYVCT90TKDOSGQFVQX2T--5FBS5MYS2COPUCJLPJIHW 50LAP ARRAY ON MAIN HOUSE 1 1 89 kW • (29)LG LG4 I ON2W-V5 WATT PV MODULES DESIGN 4 DRAFTING BY (1)STRING OF(13)MICRO-INVERTERS.(1)STRING OF(1 2)MICRO-INVERTERS 4(1)STRING OF(4)MICRO-INVERTERS -(3)STRINGS TOTAL ELEMENT ENERGY LLC REVIEW BY J M NABCEP CERTIFIE STRING #I - _ _ - - - _ _ - - - _ - ��0V NEWy 051112-I29 r- ------------ - - - - - - - - - - - - - - - - - - - - - - �P _Gt0 A G �� REV15I0N5 I �!" DESCRIPTION DATE REV y ORIGINAL OG-21-2021 MICRO-INVERTER ENPHA5E 107PW5-72-2-U5 j� [f[ 240 VAC 1 21 A r"n W AX AC OUTPUT POWER 25OVA I STRING #2 _ _ _ _ 975%CDC-WEIGHTED EPF NEMA 6,UL LISTED --------------- WICAL N - - - - - - - - - - - - - - - - - - - - - - SOA 103443 ------------== ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- �OFESSIOON" I i TO UTILITY GRID I 1 STRING #3 1 N I 1 ——————— — BI-DIRECTIONAL CONTRACTOR I I T — — — — — UTILITY METER I-PHA5E,240 V -- ai Wj II __ ' N POIIITOFINERCOIIIIEGTIOII ELEMENT ENERGY, LLC ENPHA5E BRANCH PER IIEC 24O 2 I(BX I)6 G90 G4(A) CIRCUIT CABLE TYPICAL IENGTn NOF TAP COt011710R5 7470 SOUND AVE I SHALL OT FJ(CEEO I OFT ( i i MATTITUCK, NY 1 195 LICENSE # 43(553—H I I I N I LICENSE # 52689—ME I I VAiv SE.v�E L'iS�JuvEaT 24 JV 2D=A I I I I i I I I I I I 1 I I PROJECT NAME I i I N L LI GI N LI N LI TI to i q 1 e I i W MAIN SERVICE PANEL 1.I_I I 1 AC DISCONNECT 140 VA, W m N AC COMBINER BOX 240 VAC.GOA 50 D D223NRB 1..e' "AZKq Q HEMA R.uL usreD G N ' ,Et K A'SU611f 5S�A 1 (2)50 A FUSES ii V / I EXISTING GROUNDING ` 50A I ELECTRODE 5Y5TEM r 1 i Z I M N I W ___________________________________________ ________________--- o —___ C ----_--------__-------.V-----------_--_--__--_---___ w L[ z O n/ WIRE CONDUIT SCHEDULE 't Q5 CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS MAX CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop D # ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE �\ 310 1 5(BX3) 310 15(13)(20(34 /0i U INVERTERS COMBINER PANEL AWG#1 O 1 G 08 U5E-?/PV Wire AWG#8 1 BARE CU FREE AIR I" 70-C O G5 I 10 FT 24% OR EMT 2 COMBINER PANEL AC DISCONNECT AWG#8 1 3 1 THWN-2 AWG#8 1 TNWN-2 CU PVC 1., 45aC 087 50 FT 1 1% (3 AC DISCONNECT MAIN PANEL AWG#G 1 3 1 THWN-2 AWG#B 1 THWN-2 CU PVC 1.. 45aC 087 10 FT 0 1% ELECTRICAL NOTES SHEET NAME CALCULATIONS FOR CURRENT CARRYING CONDUCTORS I )ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION #I PV Source Circuit Wire Ampacity Calculation CONFIGURATION 2)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 909C WET ENVIRONMENT [NEC 690 8(5)(1)] (I5c)'(#of 5trin s'(I 56) = 1 9 66 A 3-LINE DIA. 3)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY g ) Modules per String 13, 12 4 TO,AND LOCATED AS CL05E AS P05SIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY AWG#10,1 9 GG ty'Temp r eDC = 5i 8 A 20.8 A> 19 66 A, therefore DC wire size is valid Modules per Inverter I 4)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL Number of Inverters 29 COMPLY WITH NEC I 10 26 #2 Inverter Output Wire Ampacity Calculation 5)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS CONTRACTOR SHALL Inverter Max Amperage output' (1 25) = 43 86 A Record low temp -I O°C FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACE550RIE5 TO FULFILL AWG#8, ampacity'(femp Derate)'(Conduit Fill [)crate)= 47 85 A Voc Temp Coefficient -O 247./-C DRAWING SCALP APPLICABLE CODES AND STANDARDS 47 85 A> 43 86 A,therefore AC wire size Is valid DC SYSTEM SPECIFICATIONS CALCULATIONS G.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, #3 Combined Inverter Output Wire Ampacity Calculation Operatmej Current 9 9 A =(#of strin s)'(Im ) N .T.S. THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Inverter Max Am era e output' (1 25) = 43 86 A 7)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE p g p O eratln Volta e 41.4 V =(#modules In serie5)'(Vm ) 8)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE AWG#6, ampacity'(Temp Derate)'(Condult FIII Derate) = 65 25 A Max 5y5tem Voltage 54.0 V = (#modules In series)'[(((-###O/.VP-C'O 1)'(Lo Temp#1W-C-25))'(Voc))+Hoc)] SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERIS INSTRUCTION 65 25 A> 43 86 A,therefore AC wire size Is valid Short Circuit Current 13 2 A =(#of strings)'(Isc)'(I 25)per Art 690 8(A)(1) 9)MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G E C VIA WEEB LUG AC SYSTEM SPECIFICATIONS SHEET NUMBER OR ILSGO G15L-4DBT LAY-IN LUG Max AC Output Current 43 86 A OR PV-5 I O)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positive/negative) O eratln AC Volta e 240 V 1 O)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90 35 TAX MAP: 1 000 128000100007000 Zoho Sign Document ID JYVCT90TKDOSGQFVQX2T--5FBS5MYS2COPUCJLPJIHW SERVICE METERO O DESIGN 4 DRAFTING BY _ I N5TALLATION NOTE ELEMENT ENERGY LLC SOLAR PV SYSTEM PHOTOVOLTAIC PHOTOVOLTAIC SYSTEM ( 1 ) ALL LABEL 5HALL BE I N5TALLED IN REVIEW BY M NABCEPCERTIFIE 051 I I2-129 EQUIPPED WITH I I SOLAR BREAKER DC DISCONNECT ACCORDANCE WITH THE 2017 NEC RAPID SHUTDOWN ! ® • ' REQU I REM ENT5. REVISIONS OPERATING � •' CURRENT DESCRIPTION DATE REV (2) ALL LOCATIONS ARE APPROXIMATE AND ORIGINAL 06.21_2021 SOLAR AG LOAD CENTER - OUTSIDE I MAX SYSTEM I DO NOT RELOCATE THIS� O VOLTAGE , REQUIRE FIELD VERIFICATION. ovERcuRRENroErncE ° (3) LABEL5, WARNING(5) AND MARKING 0IO SHALL BE IN ACCORDANCE WITH NEC TURN RAPID SHUTDOWN SWITCH TO O THE'OFF POSITION TO SHUT DOWN i 1 10.2 I (B). I PV SYSTEM AND REDUCE — ----�--- ! CAUTION SHOCK HAZARD IN THE ARRAY I AC DISCONNECT POWER TO THIS SERWCE IS ALSO SUPPLIED (4) THE MATERIAL U5ED FOR MARKING -- ! FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MUST BE WEATHER RESISTANT, IN SOLAR AC LOAD CENTER - INSIDE O UTIUPMETER NTHEGARFGE COMPLIANCE WITH NEC 1 10.2 1 (B)(3). CONTRACTOR r � 3 i - I i PP,�R97470 (5) THE PV SYSTEM CIRCUIT CONDUCTORS4 7 8 1 1 OWARNING WARNING ELEMENT ENERGY, LLC. O O O O � � SHALL BE LABELED INSTALLED INTHIS EQUIPMENT FED BY MULTIPLE DUAL POWER SUPPLY SOUND AVE SOURCES TOTAL OVERCURRENTDEVICES, EXCLUDNG SOURCES:UTILITY GRID TING OF ALLI a, COMPLIANCE WITH NEC 690.3 I MATTITUCK, NY 1195 MAIN SUPPLY OVERCURRENT AND PV SOLAR LICENSE # 43889-H DEVICE,SHALL NOT EXCEED ELECTRIC SYSTEM CONDUIT - INSIDE BUILDING Ar+PncrrvOFBUL �"'°' =A LICENSE # 52689-ME 30 O WARNING N I N G E � ! WARNING THIS SERVICE METER �VIIARIS ALSO SERVED BY A PROJECT NAME ELECTRIC SHOCK HAZARD I PHOTOVOLTAIC SYSTEM 9 PHOTOVOLTAIC SYSTEM TERMINALS ON THE LINE AND COMBINER PANEL LOAD SIDES MAY BE ENERGIZED L DO NOT ADD LOADS J CONDUIT - OUTSIDE BUILDING ---NTHEOPENPOSITION a. - - ---- UJ LU ® • - - w � � -0,&WARNING ®® ®®_® C) o DUAL POWER SUPPLY � W ISOURCES.UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM �/ z MAIN SERVICE PANEL - OUTSIDE O A CAUTION SOLAR CIRCUIT ' - CD O O O SOLAR ELECTRIC SYSTEM CONNECTED LLJ 11F© • milli �; A T"Iftoff(SW 490" PERATING CURRENT MAIN SERVICE PANEL - INSIDE r �I VI/ARNINV11 OPERATING ALTAGE ,• SLTS POWER SOURCE I ISHEET NAME; OUTPUT CONNECTION ® O I RELOCATEDO NOT OVERCURRENTDEVICE OF NEIN O A yo LABELS � Gi�� AC DISCONNECT/BREAKER W n U DRAWING SCALE � l � N .T.5. locO103443 L oOFESSIoNP SHEET NUMBER PV—G TAX MAP: 1000128000100007000