Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
46227-Z
�oo��S11FFOlp- Town of Southold 9/19/2021 ,t P.O.Box 1179 CA • 53095 Main Rd 41 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42343 Date: 9/19/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1855 Depot Ln, Cutchogue SCTM#: 473889 Sec/Block/Lot: 102.-1-9.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/14/2021 pursuant to which Building Permit No. 46227 dated 5/11/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mount solar panels on existing dwelling as applied for. The certificate is issued to 1855 Depot Lane LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46227 6/22/2021 PLUMBERS CERTIFICATION DATED briz nature �o�SofFoi,��o TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46227 Date: 5/11/2021 Permission is hereby granted to: 1855 Depot Lane LLC 1855 Depot Ln Cutchogue, NY 11935 To: Install roof mount solar panels on existing dwelling as applied for. At premises located at: 1855 Depot Ln SCTM #473889 Sec/Block/Lot# 102.-1-9.1 Pursuant to application dated 4/14/2021 and approved by the Building Inspector. To expire on 11/10/2022. Fees: CO-ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 ACCESSORY $50.00 Total: $200.00 Building Inspector Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® sean.deviin(cD-town.southold.ny.us Southold,NY 11971-0959 ®l�C®UNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: 1855 Depot Ln LLC Address: 1855 Depot Ln city-Cutchogue st: NY zip: 11935 Building Permit* 46227&46228 Section: 102 Block: 1 Lot 9.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GreenLOgiC LLC License No. 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel 100A A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 17.280kW Roof Mounted PV Solar Energy System w/ (48) Sunpower SPR-E20327- E-AC Panels, Sun Power Monitor , 100A Sub w/240x4 Notes: Solar Panels on Barn and House Feeding House ' Inspector Signature: <, Z Date: June 22, 2021 S.Devlin-Cert Electrical Compliance Form �arf SOUIyO 2- -- # # TOWN OF SOUTHOLD BUILDING DEPT. cou765.1802 ,- INSP-ECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/C-AULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: t'jAene w 4 ZE/ f DATE INSPECTOR �_ 7 o��OFSOUTy� 6 ��� ��S <D ep*-4- bi # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ .] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] 1NSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: a /0 CX DATE INSPECTOFG,7Z �� ���aof oulyolo * # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION_ [ ] FOUNDATION 1ST [ ] -ROUGH PLBG. [ ] FOUNDATION 2ND [ NSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE-&-CHIMNEY ' [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT,PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE ' INSPECTOR FIELD INSPECTION REPORT DATE GOMIVIENTS FOUNDATION(1ST) ----------- -------------- -� U FOUNDATION(2ND) ROUGH FRAMING& -- PLUMBING ' r r INSULATION PER N.Y. S.TATE'ENtRGY CODE f1 f FINAL ADDITIONAL COMMENTS 4- -cicc4- dc Lff,r go • cam-Z rn • 'moo H O _ x x TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. old Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 �_ Single&Separate t, V's Truss Identification Form Storm-Water Assessment Form ,� SPR 2021Contact: Approved 120 Mail to: Green Logic LLC Disapproved a/c „ ; 97 North Sea Road, Southampton, NY 119b 3 Phone: 631-771-5152 Expiration ,20 ��_ ,� Building Inspector APPLICATION FOR BUILDING PERMIT Date April 7, -, 20 21 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applic t or name,�cormporati 97 North Sea Road, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician;plumber or builder Contractor Name of owner of premises 1855 Depot Lane LLC (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer Nesim Albukrek, President (Name and title of corporate officer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-ME Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 1855 Depot Lane Cutchogue House Number Street Hamlet County Tax Map No. 1000 Section 102 Block 1 Lot 9.1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system on houseam (Description) 4. Estimated Cost $63,000 Fee $200 (To be paid on filing this application) ' 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear. Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase 6/11/2018 Name of Former Owner Robert Et Joyce Barry 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO X 1855 Depot Lane 14.Names of Owner of premises 1855 Depot Lane LLC Address Cutchogue, NY 11935 Phone No. 631-379-6166 Name of Architect james J. Stout Address_ 2 Greg Ln, E. Northport Phone No 631-858-9388 Name of Contractor GreenLogic LLC Address97 North Sea Road Phone No. 631-771-5152 out h ampton, 68 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF,YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to,perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworq to before me thi day of f 20 - K_ Notary Public BARBARA A CASCIOTTASignature of Applicant Notary Public-State of New York No.01-CA4894969 ®ualified in Suffolk County Commission Expires May 11023 BUILDING DEPARTMENT- Electrical Inspector L4TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold New York 11971-0959 W. "W� Telephone 631 765-1802 - FAX 631 765-9502 y rogerr(asoutholdtownny.aov -- seand�Dsoutholdtownny aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 4/7/2021 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 438587ME email: AM@Greenlogic.com Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance Address-: . 97 North Sea Road Southampton; NY 11968 JOB SITE INFORMATION (All Information Required) Name: 1855 Depot Lane LLC Address: 1855 Depot Lane, Cutchouge, NY 11935 Cross Street: Phone No.: 63 ,: Bldg.Permit#: `�(v�2'( ' Tl email:bruce.brownawett@5tonybrook.edu Tax Map District: Section: 102 Block: 1 Lot: 9.1 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (48) SunPower SPR-E20-327-E-AC panels It (48) SunPower SPR-E20327-E-AC inverters (1) SunPower PVS6 monitor System Size: 17.280kW 20 panels are o house/ 18 panels are on barn) Check All That Apply: Is job ready for inspection?: DYES ❑✓ NO ❑Rough In OFinal Do you need a Temp Certificate?: OYES [:]NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ON Additional Information: In garage: Swap existing 100amp subpanel with new 225amp busbar subpanel protected with 125amp breaker. In Barn: Install 100amp subpanel PAYMENT DUE WITH APPLICATION Electncal Inspection Form 2020.x1sx I� PERMIT# Address: Switches ------- ------------ ------------------ --- -----------------------------------------------------—------- - -------------------------------- Outlets CFI's Surface Sconces HH's �J v "�rz-T UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes Dw Service - - -- — - - - - - --Micro,-- Combo - -Cooktop Tra•nsf-er AC AH Mini Special: Comments: •�/� �� �2 �C7?- � 7 GREENLOGIC® ENERGY April 7,2021 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: 1855 Depot Lane LLC 1855 Depot Lane,Cutchogue, NY 1000-102-1-9.1 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application • Owner authorization • Consent to Inspect • CO Application • Stormwater Worksheet • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec.sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec.sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, J`3wdtwm eac ddtac Barbara Casciotta GREEIALOGIC I LCM-www.GreenLogic.com Tel: 631.771.5152 Fax. 631.771.5156 ccoun anager SOUTHAaNWt@@Greenlogic-Gar YN HEIGHTS 97 Nort63da771,-5a&23ext. 11P0 S.Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 i SURVEY OFLOT of JOSEPH & BARBARA GRATTAN FILE No. 11183 FUO JUNE 27,2088 SITUATE CUTCHOGUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK AOT S.C. TAX No. 1000-102--01-9.1 SCALE 1"=30' SEPTEMBER 8, 2007 a� r B / NOVEMBER 25.2008 ADOTD DRY BLOC.NOTE JANIU.gY. 33.2009 STAKE FOUNOAM0+1 FEBRUARY it, 2009 FOUNDATION LOCATION ARE2�`80.077 SB sq.if. 't L ROBERT J.BARRY JR JOYCE R.BARRY WELLS�.1 K. !// � +wSTEWART TM-ENSURAN EC COMPANY �a 3 � .' �� �Jr /// � /baa• ��// � FEBn10 mwu k MOWN 9ry�m°Mov..m�n�m O"a /// YMtD/N fiQ�R611��R8�amr[pw, i/ � .41M.'aT lYaaN AR Naf WNWIm. � /t/ rnwam wn n[waw Nathan Tait Corwin IIB g -t r Land Surveyor � '•. `� tiL Cu V.'—MMb..—9b K— CmrOnslbo loyooc ,. PN6ME tu�1m-tam ra.(e,i»21-fm orm�mun u Abltm sootier N.Y.&Ik,Na.6467row�4w4�i�itsD� f.esM+J.PC Ilk.ISO, � d L) OCCUPANCY OR APPROVED AS NOTED USE IS UNLAWFUL DATE: B.P.# SIT ROUT CERTIFICATE FEE: �'� &-PBY: OE OCCUPANCY NOTIFY BUILGING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST Additional BE COMPLETE FOR C.O. Certification ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW May Be Required. YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOUTHOLD TOWN ZBA m SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES N.Y.S.DEC -, J A M E S J. S TOUT A R C H I T E C T & Assoc. 2 G REG LANE EAST NORTHPORT N. Y. 631 - 8 58 9388 40 U Letter of Certification March 26,2021 RE: Brownawell Residence 1855 Depot Lane Cutchogue, NY 11935 To Whom it may concern: I, James J.Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 130-mph wind design load as per 2020 Residential code of NYS(RCNYS),2020 building code of NYS (BCNYS) residential code, 2020 Energy conservation construction code of NYS (ECCCNYS)and the 2017 National Electric Code NFPA 7012017 National Electric Code,and the ASCE 7-16. The existing 2"x 10"@ 16"o.c. roof rafters will provide adequate support. Thank you for your understanding in this matter. James J.Stout Architect T 0 1633 �O F F NE`N ` Z LOGICU�l I ,I '.''.S GreenLogfc,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Suft"#A: Total System Size:17.280kW Array Size:7.200WV 1 Circuit of 10 on a 20A Breaker 1 Circuit of 10 on a 20A Breaker Azimuth:131' Pitch:40° Monitoring System: 2 SunPower Pand/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower invisirnount Panel:61.39"X 41.18" Array:25'9 7/8"X 13'11" Surface:27'3"X IT 2" M is#:Invisimount x ;R end: 20 SunPower 327W AC Panels SunPower invisimount Rai • 70 S5!-S Clamps fl B Snap Lock Aluminum Standing Seam Roofs aced 20'on center Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S51,SunPower Added Roof load of PV System:2.84psf En neer/ArchitectSeal: �aF- ARc 33 `t�Q Drawn By:MMB Drawing#1 of 11 Date:3/25/2021 REV:A Drawing Scale:1/8"=Iff I GreenLogfc,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#A: Tdal System Size:17.280kW Array Size:7.200WV 1 Circuit of 10 on a 20A Breaker 1 Circuit of 10 on a 20A Breaker Azimuth:131* Pitch:40" Monitoring System: Aof SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39'X 41.18" Array:25'9 7/6"X 13'11" Surface:27'3"X 1 T 2" Ma is#:Invisimount L end: I IL ® 20 SunPower 327W AC Panels SunPower Invisimount Rai • 70 S5!-S Clamps B Snap Lock Aluminum Standing Seam Roofs aced 20"on center Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S5!,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: �FtE° ARe 21 3� yOQ � NEIN Drawn By:MMB Drawing#2 of 11 Date:3/25/2021 REV.A Drawing Scale: 1/8"=1.0' ,LOGIC' C,VW1.0gfc,LLC Vprowd Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#A: Total System Size:17.280WV Array Sae:7.200kW 1 Circuit of 10 on a 20A Breaker 1 Circuit of 10 on a 20A Breaker Azimuth:131* Pilch:40° Monitoring System: 2 SunPower Panel/Array Specifications; Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount 2 Panel:61.39"X 41.18" Array:25'9 7/8"X 13'1 V Surface:2T 3"X 1-P 2" Magic#:Invisimount 2 Legend: Ell 20 SunPower 327W AC Panels — SunPower Invisimount Rail • 70 S51-S Clamps 1 19 Snap Lock Aluminum Standing Seam Roofs aced 20°on center Notes: Number of Roof Layers:1 Height above Roof Surface:4-- 1 Materials Used:S5!,SunPower Added Roof load of PV System:2.84psf En sneer/Archttect seal: ED Aqc i C� 21 3'' OQ TF NEY,-1 Drawn By:MMB Drawing#3 of 11 Date:3/25/2021 REV:A Drawing Scale:1/8"=1.0- I IV, " LOGIC' GreenLogfe,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#B: Total System Sine:17.280kW Array Size:5.040kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker Azimuth:131' Pitch:37° Jew Monitoring System: 2 SunPower Panel/Army Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 13/16"X 10'3 W Surface:25'7 X 11'9" M is#:Invisimount Legend: © 14 SunPower 327W AC Panels SunPower Invisimount Rai • 34 S5!-S Clamps 88 Snap Lock Aluminum Standing MIIX x x x X - x x Seam Roofs aced 20"on center Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S51,SunPower Added Roof load of PV System:2.84psf EngineedArchiltect Seat: i aED Aqc� 21 33 OQ Drawn By:MMB Drawing#4 of 11 Date:3/25/2021 REV:A Drawing Scale:1/8"=1.0' LOGIC" QreenLogic,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#8: Total System Size:17.280M Array Size:5.040kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker Azimuth:131° Pitch:37° Monitoring System: 2 SunPower Pand/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount AN Panel:61.39"X 41.18" Array:24'4 13116"X 10'3 Y27 Surface:25'7 X 11'9" M is#:Invisimount Legend: 14 SunPower 327W AC Panels SunPower Invisimount Red • 34 S5!-S;Clamps 8 p Snap Lock Aluminum Standing U Seam Roofs aced 20"on center Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S51,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: RED AjR 3 T 21 33 OQ TF NES y Drawn By:MMB Drawing#5 of 11 Date.3/25/2021 REV.A Drawing Scale:118"=1.0' .,LOGIC' GreerrLoglc,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#B: Tctal System Size:17.280M Array Size:5.040M 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker Azimuth:131' Pitch:37" Monitoring System: 2 SunPower Panel/Arra Specifications: Panel:SPR-E20-327-E-AC Racking.SunPower Invisimount Panel:61.39"X 41.18" Array:24'413/16"X 10'3 IN Surface:25'7 X 11'9" 4 Ma is#:Invisimount Legend: 14 SunPower 327W AC Panels SunPower Invisimount Rad • 34 S5!-S Clamps 3 11 Snap Lock Aluminum Standing Seam Roofs aced 20"on center Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S51,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: �ccLED ARc O� 4r 21 33 OQ TF NES`� Drawn By:MMB Drawing#6 of 11 Date:3/25/2021 REV.A Drawing Scale: 1/8"=1.0' JOW Y , h.J LOG ICS i GreerrLoglc,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#C: Total System Size:17.280kW Array Sim:5.040kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker Azimuth:311" Poch: Monitoring System: SunPower Pand/Array,Specifications: Panel:SPR-UO-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 13116"X 10'3 W Surface:25'7 X 11'9" Magic#.-Invisimount Legend: 14 SunPower 327W AC Panels SunPower Invisimount Rail • 34 85LS Clamps I8 Snap Lock Aluminum Standing Seam Roof spaced 20"on center Notes. Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:SSI,SunPower Added Roof load of PV System:2.84psf i Engineer/Architect Seal: i i AED ARC i _ TF 21 33 'LCQ, NES Drawn By:MMB IDrawng#7of1l Date.3/25/2021 1 REV:A Drawing Scale:1/8"=Iff ` N LOGIC" G wenLogfc,LLC Approved Brownaweil,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#C: Tdal System Size:17.280WV Array Sim:5.040kW 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker Azimuth:311° 37* Pitch: UOT Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 13/16"X 10'3 IN Surface:25'7 X 11'9" Ma io#.Invisimount Legend: 14 SunPower 327W AC Panels �— SunPower Invisimount Rail • 34 S51-S Clamps 5p Snap Lock Aluminum Standing Seam Roofs aced 20"on center Notes: Number of Roof Layers:i Height above Roof Surface:4" Materials Used:S51,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: ��aEo ARS C-,bp C , T 1� na Ar 21 33 OQ� TF N�`N J Drawn By.MMB Drawing#8 of 11 Date:3/25/2021 REV:A Drawing Scale:118"=1.0' F IOGICO GreenLogtic,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Surface#C: Total System Size:17.280kW Array Sae:5.040WV 1 Circuit of 7 on a 20A Breaker 1 Circuit of 7 on a 20A Breaker Azimuth:311° Pitch: Monitorinrin g System: SunPower Pand/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 13116!'X 10'3 I Surface:25'7 X 11'9" 6 M is#.Invisimount L end: 14 SunPower 327W AC Panels SunPower invisimount Rai • 34 S5!-S Clamps 5 I B Snap Lock Aluminum Standing Seam Roofs aced 20"on center Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S5!,SunPower Added Roof load of PV System:2.84psf En 'neer/Architect Seal: aED Aqc 21 33 OQ lF NES-1 Drawn By:MMB Drawing#9 of 11 Date:3/25/2021 1 REV:A Drawing Scale:1/13"=1.0' No Vent Pipes Will Be Covered By The Solar ArraX :. ,::, ;LOGICS Legend: treenLogfc,etc Approved AR-Access Roof AP-Access pathway,36"minimum width SVO—Setback at ridge Brownawell,Bruce and Anne 1855 Depot per R202 definitions per R324.6.1 as per R324.6.2.1 Cutchogue,NYn11935 M ter Total System Size:17.280WV 1 Circuit of 10 on a 20A Breaker 1 Circuit of 10 on a 20A Breaker 2 Circuds of 7 on 20A Breakers 2 Circuits of 7 on 20A Breakers Azimuth:131' I � Monitoring System: SunPower ®rcmw Panel/ASpecifications: I Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount I Panel:61.39"X 41.18" I Magic#:Invisimount D a Legend: X48 SunPower 327W AC Panels 3 �-- SunPower Invisimount Rail rt • 138 S5!S Clamps N Snap Lock Aluminum Standing I Seam Roofs aced 20"on center C) Notes: 14 SunPower Number of Roof Layers:1 327W Panels 0 1 Height above Roof Surface:4" 3 I Materials Used:S5!,SunPower = I Added Roof load of PV System:2.84psf o AP: r- - I I En 'neer/Architect Seal: m i AP o �----- -------I ��aED Aft, C/) Ny W& \V \1 I -_—_SV4__ ___ SVO—__ 20 SunPower cD 327W Panels fl. I I r INE T 21 i1,1 F �E� 1 Drawn By:MMB Drawing#10 of i 1 14 SunPower IZAC Date:3/25/2021 REV:A 327W Panels Drawing Scale:3/3Z'=1.0' LOG IC' GreenLoglo,LLC Approved Brownawell,Bruce and Anne 1855 Depot Lane Cutchogue,NY 11935 Total System Size:17.280kW 1 Circuit of 10 on a 20A Breaker Material List gtY Rail Material list I Circuit of 10 on a 20A 2 Circuits of 7 on 20A Breakers Breaker 2 Circuits of 7 on 20A Breakers Azimuth:131' 551-5 Clamps 138 Monitoring System: 2 SunPower Panel/ASpecifications: Panel:SPR-E20-327-E AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Magic#:Invisimount L end• ® 48 SunPower327WAC Panels SunPower Invisinount Rail • 138 S51-S Clamps 10 Snap Lock Aluminum Standing Seam Roofs aced 20°on center Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:S5!,SunPower Added Roof load of PV System:2.84psf En neer/ArchltectSeal: %j6ED ARC O� 21 33 OQ TF N6`N y Drawn By:MMB Drawing#11 of 11 Date:3/25/2021 REV:A Drawing Scale:3132"=1.0' .. „ri,4-7-7, :77,,,�n�`.,....«K. �•7 iAe.+� x�ea "� � q ��✓a ., sin^-_ --'„ , v VA B r Simple and Cast Installation F71, lrtegrateca module-4o-rail grounc n A Pre-assembled mid and erd r:Damns tevil a= g m r plan merit �n ,Id cEarn for eaTv��- e Mid clainp`s^.idh tacilir%.CFS i;t}tlSlst°?tlt't evetl ' mod4e spa yrn m Simlpie,P £,;-;1led rail 2/0'1 Listed f tegrated greuri a.,ng Plexible Desigr) " Addres:,cs nearly all s;oocd res;de rld-_fl rc ofs • L)��si�rr ir�,l�rldscape�,rrt�pUr;�a;r Rails e^utae e:lsy obstc<cle moragerr`en, Customer preferred Aesthetics �. mcculc and#" trcunt}ng aesthetics Ces:-Ir class system,aesthetics Fie-ant Simulicity Prerr ii_, n,:crate"prof le desigr B:adcanodizeccomponents SunPower,' InvIsiMOUnt", is a S-nPower-des,gned Il,dder m d damps and°er cl camas rail-based mount ng sys,err, The Invl-,;Moan system and capper,filus;i rams addresses '"esider-na sloped roofs a-d combines faster" Part of Superior System ir'SCcll,ation tirric', dC'S<<grl Fli'Xik)1111y, and superior aesthetics Built for use wltn Stanncwer DC and AC moc ules -I he InvisiMount producr was Spec,flcally envis oned 'Y'd NFs:-Ir-dans systems-.retraulit,r and aes,Tics -arribine vvvi Sur-Fra'orer TodOps chit crigineered to pair.Kith SunPower rT;O()'UIC's. I he resulting M.Omkiing app syscern-level approach will arnplify the, aesthetic arc 3 i-stallation ber,efiis for both homeowners and installers, sunpowel",Com �.ra 4 0- 1W4 M-3,4W MZ4 WN M- 51 "S Win, T PA ACO i mid r 1,M)p and Rail Erd"Ijmj,;'Id Ra I 0� V11F, Wicl Oa,r,r) -nd Uarrn ,'ail R R,I Spl,,-e J_Ug Aq,;F-Mnly End Cap IN 'v i 'Sud Mi Temp&,,;iurc -40'C to 90'C(40'r to 19-1*F) Component Nlaten�d "lie gIjT MFx -,,)au(LRrD) 3000-13 UPI ft mi'l Clamp Er-u K oxice s-.ainles,:�,led AISI?04 6'�g�2 oz� End Clamp 6 ac,<a,jdi7e0 aluminurn,1110Y S,)53-T-, 1 110 g(3 88 07) ILI Rall 830 g/r, o7,,,) 0:14111;; rwil sollce Ali nur,tj1TjaIlo\j60',)5T5 83C g/m odic) 25-y.,at krod,jctwar,a,,,,,/ --. -- i - I Waranlies Ground Lug 304,qaio ess 1 5 1 CC, (175 o;) -earfi-s-,,.varrantv Assemoly (A2-70 bo,t,Ir-pate-�-Wr)el Ug) (Ind Cat, BlackBlack acetal UL 27:,-,,_Sled Ca,oFicallcrs C a,.q A Firp RF,-,Pd rompostion nglp Rafter ktachrrer, Sh r),,Ie Roof Dec\r,g Attar)r-ion, N"k NOMM-011; Application �l C,irv-,dano-lotTle Roof A,Lauirrietu Uro e,sal 1,1ci-face for 0:her Roof Attacnnicrit, Refer to roof attacl-,-ne-it harcv%,ai2 manu'3cz,---ers c;oc,rncn-,auo- 'rinr tw s comm-,nioWth tl',-"NSitv"OUM oqtmed for harow-if, AIM?�tsRese-4d SIPPOW-R,,liz-SUNPOW;:R logo A' :orn are -nourc, Document#509S06 RevC 4 m U P WE R00 un ®werO E-Series: E20-327 I E19-320 l SunPower' Residential F AC Module Built specifically for use with the SunPower Equinox«'system,the only fully integrated solution designed,engineered,and warranted by one manufacturer, Maximum Power. Minimalist Design. industry-leading efficiency means more power and savings per availaole space With fewer modules required and hidden microinvertei s,less is truly more Highest Lifetime Energy and Savings. Designed to deliver 60%more energy over 25 years in real-world conditions like partial shade and high temperatures.! 14(155 Fundamentally Different: a And Better. 'up to 04, ;60 % cTo is-)r 'more (lifetime lot energy 9 S 00 -, The SunPower�Maxeon~Solar Cell' Years of operation • Enab,;:s higliest-efPrienov rrocule;avai able.= Best Reliability. Best Warranty. • unmatched reliability'' ' • Pat:r,:ec sold raeial fc::ndation With more than 25 million modules deployed around pr evens breakage and cor rosicf, .- the world,SunPower technology is proven to last That's -- �� why we stand behino our module and microinverter ' with the industry's best 25-year Combined Power and a Product Warranty,including the highest Power Warranty in solar Facto inte ratedMicroinverter a X54 • Simpler,faster;nstailafior- ° o • Integrated v:•ire raa�;agem4��t. . _ E ao� � ° ° i12!• raDid snutdown !more • aid calibrated by'' ° ower En�ineereci 5 e !e� s45n year 5�nPovger 30, u 1 c,vver iron azo. rme, �x d„ 25 Years of operation ®. asheet E-Series: E20-327 E19-320 SunPower"Residential AC Module Data Inverter Model-Enphase IQ 7XS(IQ7XS-96-ACM-US) @240 VAC @208 VAC Ppax 0,itnut i'o•ver ----- ---- --- 320 VA 320 VA May Contin,to r CJJCUUr PCil;r±r 31 5 VA 715 VA -- Noin ;L-L)V,)IraFe/Range,(V) 240!211-264 208/181-229 i 31 -- 151 - --- - ----- - -- -------- ------------- - ------ Nlar Units per 20 A(LL)G astcF Circur,t 12(s igle phase) 10(two pule)wye — -- ---- - ------ --- ---- ---- ------------------ C C Ignte,rl C-ff.clenc y 97S% 97:)4h Nom Freq!)r-r1r/ 60 H7 -------- -- ---- -- ---------------- ------ --- ------ ---------- ---------- L>ren,jec g regL,ency'fan; 47-t 8I lz A!-Strc>rt C'rcuit rauir r,ere^.t Over SCyr es ----------- - --- -5 8 i,r ens '-- ------------ OvarJo`rsge U:._s A`.P(,t ----- 'I -------- AC Pcrt G:rI•(r:a Cu•tzr• 18 mA -------------------------- - ------ -- --- --- po<,e,Factc-Sert"g 1 0 ------ ------------- ---------------- -------- - ------------- -- o,,.._"rackr:r(ad „h e) ------------- 0 7 leas / 0 7 ag No aave phase oalsnr n fcr tiree-p-ase•nsta la_pr`s V0 ® Q SPR-E20-327-E-AC - SPR-E19-320-E-AC I I 25-ycallimited powrwair3r,;y +1�'arraules I Nom PowerS(Pnorr;) s27 320 W I 25-year hmltedproducrwair3ny --- — @@vier 1of +S/-Oe5 5/-015 I UL 1 703 Ccitifications UL 1721/IEEE-154% Module Effic,erizv 20 4% 19 946 UL 1741 AC Module(T}.oe 2 fire rated) - ----- - and . Temp Coef(Povaer} -- -0 354c,''C -- --0 35"7%"C CpmU-62.109-"/I=C:62.109-2 pl ante FCC Par,art 15 Class 8 •Tnree bypass c lodes ICES-0003 Class 13 Shade Tol lntegra;ed rn=le level rnaxirnurn ClAN'CSA C22 2 NO 107 1 01 power pant t1 ackmg CA le 14. (includes Volt/Var and Reactive Power Prier ity) • • - o • s UL Listed PV Rapid Shu(down Lgwpment`' Operating I emp -40'F to+,85'F(-«0°C to+85'C) iaax Ambient Temp 122-F(50°C) Enables Installation,n a cel dance with i •,vEC 690 6(AC rrccule) - - --- 4vinc 62 psf,3000 Pa,30,kgl;rl2 front&back NEC 69012 Rapid Snlxco,vn pnslda anr nutsidP ti nF array) Paax _uao S',or,• 125 os.`.6000 Pa 611 kg/m't ort f ___--- ------- _ __--- i NEC 69015 A'Connectors,59033(A)-(E)(1) , I,roac(Resistance 1 Inch 25 mm)diameter had at 52 mph(23 mis) Wrcn used aroitn nwslRtour,t racking zno Invis bunt&cCessones I !. (UL 2603) , odu e Rround,n a-d bonon throng'-mvisdalot_nt Solar Ce'L fv 9G onocnstz•hne iv+axeon Gen iii g -- -- ------ -�----- ------ - -- - •Class A Ire rates rGla_=_I �- High;ransmiss on tempered glzss with WI-el'WI-el'used vaitn AC rrpdole Q-,,bles e.d ac,Esso,ies;UI-6703 aid ont ant,-re`ecUve coating UL 223F},' Env.ror,rnental Rat-g Ourdoo' rated Rated for load creak d sconnect I--- ----------- ------ - =ramp Class 1 black anodized(highest AA to i ating) ITest - Potential-induced degradation free- ------ i •Are,ght 429 lbs(195 kg, - 1558 in'.(613,.1) Recomriended fvar. 1 3 in33 mm) \•locule Spacing ( ' r 1 SunPowe,350 V;rompared to a conventinna module or same sized orrys(250 W,16;5 46 mm rffiriem,aoprox 15rn"),Ii'4-forcent?rgypr-rvlatt(ba,r-don-nirdpartymodu�e } 0Sin) rharartan7acion and PVSim),r 7,,,.Iyr slowe,deg,adador,(Campc-a+I,7 et sl'S.inPower I Wodule Degradation Rale"Sunloti=;er v hi,e pznr r,291 s; 7Rased on,earrhafdacasneetyclue,from w:hs,tesoftop Iarnanufactuietsper hiS,a,of to46nun 3omm._,. January 2017 (4i]In) 341 rankin'FaunnaferaVClrabndylrn:.at.vefor;olar?ao uesPart;'PVrrrhPnver (t2m) I'agvim,2015Campeau,Zeta]'SkinPowe,ModuleDegradationRate,'Skinl`,CVxrvrnitc d_- --'- pap-r,2013 4rac-or,-etrnlWi-7ftaoe`aul,,settings CARide7ldelzidt,ettin?s F'of,Ik, during, 393 mm ! r corn miSsionmg Seethe Equinoxlnstaifatton Gutoe>~518101 fo,morernforrnati�% (155In) 5StandardTesrCoa,dltons(1000W!m',riadia•ue AA,1 S,2VC)NREI rzlib ahon Rr _ standard SOVIScuirent LACCSFFaid Voltage.All Doltage sfullycontainedwithinthe module mm _ 6 inie procurt is tit t,srec.os P:'RSE anr.ron;crms witt-NEC-7014 and NI-C 20 i 7,6,90 12, -+'^ 437 437 ) anr!C'2 1-2915 Rule 64-218 Rapid Sh_ndown of PV Systems for M-and Dt-rondurtom, (17 when,nsta11od accordu-g to manufacturei s Inti t,rt ons Ufu^.4H,UlJ 1. Uri +wxr See vivrw,umpo.=Je•coy*+/fact fcn,to•e refer�r•ce m(ar mahan. wearr,s4rtxrvra p j � E R� Farnot odetcdw s seeexterdeddatasnee!wvrvsurpo .rccmldatashe�ts cover � /�`vJ/ S,tecifrcationsindudeCirthisdatasheet=_•eauh)ecc:cchangew![hou,noJce (,I$jEE47-0ea7o `� U N .r.2018 SunPov)e,Corps•atlon A 1 Rights Res,-,,ed 5-UNPCWER:he M.61.IF-Performance Type 2 SJNPOV:ERIcgo and MA.X°CV are registereJ tradernariz c-SunPcw:r Corocratio i it.me,U S and o.hcr counrries as r eH i-803-SLP.PO"NE t P'ea°e rea,the Sa`e:y and nsta:,at on nscluct ons 1•7t Fetal S 531948 RevA 1- PV--SA-1 - — NEW EQUIPMENT — — — — EXISTING SERVICE . . = = AC-COMBINER PANEL 120/240, 1 PH, 3W • • AC-CPPB-1 � o I (PV LOADS ONLY) Pa SA—.`2 A 400A i IrKWH 2 1 _ i P - - �-CA� B ►� • • • t; BKR—t AC-DSC-1 • • • 2 1 AC DISCONNECT BKR-2 : 4 PV-5A-4- A? zfh PV—SA-5 �� I BKR-4 f MAIN • i BKR_5 i A B N FUSE© o PV—SA—6 1 r_A) BKS-6 h I • • • , S 13KR-7 EGc V t� A ( I I N PV—SA-7 f FFN • • • - EGC [ l • • • 2 1 ECC II EXISTING AC PAN LEXISTING 1 GEG GEC #-6cu - PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Brownawell, Bruce GREENLOGICO 1855 Depot Lane &-D Cutchogue, NY 11935 ENERGY ELIMINATING TETE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Brownawell-3LD1 Revision: 1 Revised: 12/15/20 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 12-MODULES PV-SA-2 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES PV-SA-3 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES PV-SA-4 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES PV-SA-S PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES PV-SA-6 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES PV-SA-7 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 6-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 4320 WATTS 211-264 VAC 17.56 A AC 240 V, AC PV-SA-2 2160 WATTS 211-264 VAC 8.79 A AC 240 V, AC PV-SA-3 2160 WATTS 211-264 VAC 8.79 A AC 240 V, AC PV-SA-4 2160 WATTS 211-264 VAC 8.79 A AC 240 V, AC PV-SA-5 2160 WATTS 211-264 VAC 8.79 A AC 240 V, AC PV-SA-6 2160 WATTS 211-264 VAC 8.79 A AC 240 V,AC PV-SA-7 2160 WATTS 211-264 VAC 8.79 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Brownawell, BruceO 1855 Depot Lane (nll 1_11 ENERGY Cutchogue, NY 11935 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION page 2 of 3 Drawing No: Brownaweii-3LD1 Revision: 1 Revised: 12/15/20 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V,200A, NEMA-1,1-PH,3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-5 CIRCUIT BREAKER, PV-SA-5 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-6 CIRCUIT BREAKER, PV-SA-6 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-7 CIRCUIT BREAKER, PV-SA-7 MATCH AC COMBINER PANEL BRAND,2-POLE,20A AC-DSC-1 AC DISCONNECT SWITCH(LINE TAP) 250V,100A,NEMA-1, FUSED; FUSE RATING:100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4-PVC-40 12 / 6 B THWN-2 2"PVC-40 4 / 6 C THWN-2 2"EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE,DISTANCE,AND DERATING FACTORS. 2.)ELECTRICAL CONDUIT TO BE MIN.PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Brownawell, Bruce 1855 Depot Lane Cutcho ue, NY 11935 ENERGY 9 ELIMINATING THE 00ST"mF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Brownawell-3LD1 Revision: 1 Revised: 12/15/20