Loading...
HomeMy WebLinkAbout46743-Z �o�OS�FF 4- Town of Southold 9/2/2021 $ P.O.Box 1179 0 o _ 53095 Main Rd 4,j �ao�s Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42323 Date: 9/2/2021 THIS CERTIFIES that the building GENERATOR Location of Property: 6505 Horton Ln, Southold SCTM#: 473889 Sec/Block/Lot: 54.-7-17 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/17/2021 pursuant to which Building Permit No. 46743 dated 8/26/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessoly generator as applied for. The certificate is issued to Esteves Hldg Corp of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46743 8/19/2021 PLUMBERS CERTIFICATION DATED A ri d Signature �SUFFo TOWN OF SOUTHOLD ��o y BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE oy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46743 Date: 8/26/2021 Permission is hereby granted to: Esteves Hldg Corp 80 Sunset Ave Selden, NY 11784 To: install generator as applied for. At premises located at: 6505 Horton Ln, Southold SCTM #473889 Sec/Block/Lot# 54.-7-17 Pursuant to application dated 8/17/2021 and approved by the Building Inspector. To expire on 2/25/2023. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF OCCUPANCY $50.00 C : $235.00 Bu ' g Inspector ®�*oF sovey®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 c sean.deviin(cD-town.southold.n .us Southold,NY 11971-0959 ®l� �O y cOUNTI,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Esteves Holding Corp Address: 6505 Horton Ln city.Southold st: NY zip: 11971 Building Permit#: 46743 Section: 54 Block- 7 Lot: 17 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: KC Anderson Electric License No: 4722ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey Attic Generator X INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 22kW Generac Generator w/ 200A Whole House Transfer Switch Notes: Generator Inspector Signature: ��'� Date: August 19, 2021 S.Devhn-Cert Electrical Compliance Form FIELD INSPECTION REPORT DATE GOM10,NTS• FOUNDATION (IST) FOUNDATION (2ND) ROUGH FRAMING& PLUMBING _ 1 INSULATION.PER N.Y. STATE ENERGY CODE FINAL ADPITJONALCQ11 NT$ ?O z m H �oguFFUL��o TOWN OF SOUTHOLD—BUILDING DEPARTMENT `Y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 N T oy 4 �6' Telephone (631) 765-1802 Fax(631)765-9502 httDss:Hw N,w southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. Building Inspector- AUG 1 7 2021 Applications and forms must be filled out in their entirety.IncompleteF�_ applications will not be accepted. Where the Applicant is not the owner,an ; Owner's Authorization form(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name:Esteves Holding Corp SCTM#1000-54-7-17 Project Address:6505 Hortons Lane, Southold NY 11971 Phone#:631-698-2892 Email:dercontracting@optonline.net Mailing Address:80 Sunset Ave, Selden NY 11784 CONTACT PERSON: Name:Jerry Cibulski Mailing Address:PO Box 598, Southold NY 11971 Phone#:631-404-2507 Email'. erryCibulski@9Mail-c0m DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone#: Email: CONTRACTOR INFORMATION: Name: Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ONew Structure OAddition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: no otherGas Generator $$10,000 o Will the lot be re-graded? OYes ONO Will excess fill be removed from premises? ❑Yes ON 1 PROPERTY INFORMATION Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to R-40 this property? ❑Yes ❑No IF YES, PROVIDE A COPY. ❑ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to,the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in buiiding(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(print name): Jerry Cibulski WAuthorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) COUNTY OF r ) Jerry Cibulski being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this I day of ,20�� Notary Public Andres G Javier infante Notary Public,state of New York NO.01JA6344007 ouaiiiied in Suffolk County CBrnmissionExpires 6/2712024 PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) 80 Sunset Ave, Selden NY I, I&AaL-el— 4-52 , �-� residing at do hereby authorize Jerry Cibulski to apply on my behalf t the Town o tduthold Building Department for approval as described herein. Owner's Signature Date 4�Print Owner's Name 2 i= l(1 ao l�c4Gy BUILDING DEPARTMENT- TOWN OF SO(lTyOLD Electrical inspector y ,? Town Hall Annex- 54375 Main Road-Pp g Southold, New York 11971.0959 Ox 1179 ro a Telephone (631) 765-180 ( 31 2-FAX 6 rr southoldtownn . ov seand )765-9502 li southoldtownn ov APPLICATION FOR ELECTRICAL INSPECTIO(u ELECTRICIAN INFO A I Information Required) Company Name: 1 t Date. r �, Name: License No.: II email- Address: Phone No.: U 7 JOB SITE INFORMTION (All Information Required I' Name: Required) Address: Cross Street: _ GS Phone No.: '( Bld P — _ 3 - D g. ermit#: email. Tax Map District 1000 j Z Section: ii Block: Lot: BRIEF DESCRIPTION OF WOR (Plea a Prin Clearly),j, "ZZ- Circle ZCircle All That Apply: f Is job ready for inspection?: YE O Rough In Fin Do you need a Temp Certificate?: YE / Nqj Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: -A #;;Meters Old Meter# ti New Service - Fire Reconnect- Flood Reconnect-Service Reconnected-Underground-Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: li , PAYMENT DUE WITH APPLICATION witXJ Request for Inspection Form.xls Reqs /C�� �- , ;f f - a•C.TM. NO DISTRICT: 1000 SECTION-54 BLOCK. 7 LOT(S).17 \ RIO-19-0117 OU P. ev \� ¢3&4 \ r \ N \ 0. o, ¢39J 370 O" We WELL \ Y ,%e'9w9'of9r \ 4 etvRoou 5 1.250 GAS g}, ��i• 0)a'm.12'O®LP. J wM1 09 WELL \ ¢See / t' S •a � raae•o® % Lh rs \ a re { a 1�+ 'l9 s.Wa., M1�\�a„G - �= ECE55 1 •\ EL 37Z / �'�('�•� t� a womw wa1 Wm a9',N ypN EL 13.7 % �f per' i SHOWM ¢3" \ �L 4'=4' i erowe'ote]r9w w[WELL g ¢3a3 014' LAND N/F OF NANCY McDONALD s �Q� 9•� ¢390 i w DRAINAGE CALCULATIONS Owe7LN0 n/omERm PORCfl6`DI+SF 1924=a1m-4aw REG09KD (�9'ON=e'0f3P ORrwev.-eJid FRJ/'IOED 9)OMMY-700 51.Fi 700=afee-117d (1)9'0P=Y"ORr#M-132d PRW00 FINAL SURVEY 06-08-21 ZONED R-40 FND LOC. 01-05-21 NON-CONFORMING LOT FND. LOC. 08-30-20 FRONT YARD: 40'MIN REVISED 03-04-20 SIDE YARD: 15'MIN, TOTAL 35' THE WATER SUPPLY, WELL$ DRYWELLS AND CESSPOOL REAR YARD: 50'MIN LOCATIONS SHOWN ARE FROM RELD OBSERVATIONS AND OR DATA OBTAINED FROM OTHERS AREA:23,893.57 SQ.FT. or 0.55 ACRES ELEVATION DATUM. NAVD88 UNAUTHORIZED ALTERAITON OR ADD177ON TO THIS SURVEY IS A WOLA77ON OF SEC77ON 7209 OF THE NEW YORK STATE EDUCATION LAW COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED 70 BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS777U77ON LISTED HEREON, AND TO THE AS51GNEES OF 774E LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT 774E PROPERTY LINES OR TO GUIDE THE EREC77ON OF FENCES, ADDIAONAL S7RUC27IRES OR AND 07HER IMPROVEMENTS EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF, LOT 6 CERTIFIED TO: ROBERT CRISCITO: MAP OR OAKRIDGE HILLS FILED: APRIL 30, 1962 No.3555 SITUATED AT SOUTHOLD Tom oF:SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORKProfessional Land Surveying and Design �If P.O. Bos 153 Aquebogue, New York 11931 FILE 619-57 SCALE:1"=30' DATE. MAY 1, 2019 ( «•�� 4 PHONE (031)298-1588 PAA(831) 298-1588 N.YS, USC, NO. 050882 —IntaWnt the M=dg et 114bat 1.H�®7 Y K=eM IL•9yLuk ate, AP RO ED AS NOTED DATE:,'�L?1191191B.P.S 3 FEE: 6v BY: NOTIFY BUILDING _,DARTMENT AT 765-1802. SAM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH FRAMINIG & PLUMBING 3. INSULATION 4. FINAL - CONSTRL MUST BE COMPLETE F-l- , 0. ALL CONSTRUCT!;:rq SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF ' BA SOIJt1jvly--�1hi6b%ING OARD SOUTH @-TOWTRUSTEES AI V C-rr�-vcv-- OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA- )F OCCUPANCY ELECTRICAL INSPECTION REQUIRED GENERAC° 20/22/24 W GUARDIAN° SERIES _ Residential Standby Generators Air-Cooled Gas Engine Standby Power Rating ' INCLUDES G007038-1 G007039-1 G007038-3 G007039-3(Aluminum-Bisqu(')-20',W 60 Hz • True Power'" Electrical Technology 0007042-2 G007043-2.G007042-3 6007043-3;Aluminum-B,sque)-22 kvv 60 Hz G007209-0 G007210-1 (Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution*"controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor — O y • Standard Wi-Fi®connectivity • System status&maintenance Interval LED Indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation yy, GENERAC _ ��- 7 ,r • 5 Year limited warranty *!' • Listed and labeled for installation as close as 18 in(457 mm)to a r structure 'Must be located away from doors,windows,and fresh air intakes and in accordance with local codes ON or C DS QUArus LISTED Note CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches Units packaged with the Smart Switch are ETL or UL certdied in the USA only FEATURES O INNOVATIVE ENGINE DESIGN &RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Force engine lineup offers added peace of mind and reliability for when it's needed els It provides optimized FAST RESPONSE to changing load conditions and MAXI- the most The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of extended run times in high temperatures and extreme operating conditions loads to the engine Digital voltage regulation at±1% O TRUE POWER'"ELECTRICAL TECHNOLOGY-Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES.Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility O MOBILE LINK CONNECTIVITY:FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone,tablet,or PC Easily access information such as the current operating status and maintenance alerts Users can connect an account to an authorized service dealer for fast,friendly,and proactive service With Mobile Link,users are taken care of before the next power outage w GENERAC @ :a s k N W� PROMISE M�b,a GENERAC' 20/22/24 kW Features and Benefits _ Engine • Generac G-Force design Maximizes engine 'breathing"for increased fuel efficiency Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life Now featuring up to a 2 year/200 hour oil change interval • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil • High temperature shutdown Prevents damage due to overheating Generator • Revolving field Allows for a smaller lightweight unit that operates 25%more efficiently than a revolving armature generator • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment • Displaced phase excitation Maximizes motor starting capability • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes • UL 2200 listed For your safety Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power • NEMA 3R Can be installed inside or outside for maximum flexibility • Integrated load management technology Capability to manage additional loads for efficient power management • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation Evolution'"Controls • AUTO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries • Main line circuit breaker Protects generator from overload • Electronic governor Maintains constant 60 Hz frequency Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph(241 km/h) Hinged key locking roof panel for security Lift-out front for easy access to all routine maintenance items Electrostatically applied textured epoxy paint for added durability • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure o GENER CC WMINUMMM 20/22/24 W Features and Benefits Installation System • 14 in(35 6 cm)flexible fuel line connector Listed ANSI Z21 75/CSA 6 27 outdoor appliance connector for the required connection to the gas supply piping • Integral sediment trap Meets IFGC and NFPA 54 installation requirements Connectivity(Wi-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due • Monthly report with previous month's activity Detailed monthly reports provide historical generator information • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery • Weather information Provides detailed local ambient weather conditions for generator location GENERAL' 20/22/24 kW Specifications Generator Madel G007038-1 G007042-2 G007038-3 G007042-3 G007209-0 G007039-1 G007043-2 G007039-3 G007043-3 G007210-1 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) 20,000 Watts' 22,000 Walls' 20,000 Watts' 22,000 Watts` 24,000 Watts` Rated maximum continuous power capacity(NG) 18,000 Watts" 19,500 Walts- 18,000 Watts` 19,500 Walts' 21 OOD Watts` Rated voltage 240 Rated maximum continuous load current-240 volts(LP/NG) 833/750/75 0 91 7/81 3 83 3/75 0 917/Bt 3 100/875 Total Harmonic Distortion _ Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz - -- - -- ---- -- -- - - - - - Power factor 10 - - - - -- - - - - -- --- - - --- - - - - --- - Baflery requirement(not included) 12 Volts,Group 26R 5.4.0 CCA_minimum or Group 35AGM_650 CCA m_mimu_m_ -- - - - - ---- -- Unit weight(lb/kg)- 448/93 466 j_21 1 430191T 198 445/202 455/206 - - - - -- - ---- - - - - -Sound -- - - -- Dimensions(LxWxH)m/cm ', 48x25x29/1219x635x737 -- - - - ----- - -- - - --- -- - -- - - - ---- - - -- --- - - - - Sound output in dB(A)at 23 ft(7 m)with generator operating at normal load 67 67 67 67 67 --- - ---- - - - -- - - - - - - - - Sound output i dB(A)at 23 ft(7m)with generator in Quiet-Test"'low-speed exercise mode"` 5557 55 57 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylindef_s - - _ __ 2 Displacement 999 cc - -- --- - -- -- - - - - - -- Cylinder block _ Aluminum w/cast iron sleeve Valve arrangement Overhead valve - -- -- - -- - - - -- -- -- - --- - - -- - - ------- - ------ ----- - -- Ignition system Solid-state w/magneto - - 'Governor - - - --- - - - - --- - -- - -- - - --- -------- --- - - -- -- - -- --- - - - = system Electronic -- - - - - -- --- ---- -- ---- - - - -- - -- - - - - - -- --- --- - -- -- -- - - Compression ratio 9_51 Starter - - 12VDC� - - -- ----- - Od capacity mcludm- -g filter - Operating rpm3,600 Fuel consumption- --- - - - --_ Natural gas ft3/hr(m3/hr) ; I 1/2 Load 204(5 78)" 228(6 46) 164(4 64) 203(5 75) Full Load 301(8 52)E, 327(9 26) 287(8.13) 306(8 66) Liquid propane ft3/hr(gal/hr)[Uhr] j 1/2 Load 87(2 37)[8 99] 92(2 53)[9 571 86(2 36)[8 951 92(2 53)[9 571 _________ T___________ __ _Full Load - 130(3 56)[13°461 142(3 90)[14 77] 136(3 74)[14 15] 142(3 90)[14 771 Note Fuel pipe must be sized lar full load.Required fuel pressure to generator fuel inlet at all load ranges-3 5-7 in water column(0 87-1 74 kPa)for NG,10-12 in water column(2 49-2 99 kPa)for LP gas For BTU content,multiply 113/hr x 2500(LP)or ft3/hr x 1000(NG) For Megafoule content,multiply m3/hr x 9315(LP)or m3/hr x 37 26(NG) Controls Two-line plain text multilingual LCD Simple user interface for ease of operation Mode buttons AUTO Automatic start on utility failure Weekly,Bi-weekly,or Monthly selectable exerciser_ V ------- - ------ - - - - - - rte -- ----- - - MANUAL Start with starter control,unit stays on If utility fails,transfer to load takes_place OFF - Stops unit Power is rem-oved Control and charger still operate -- Ready to Run/Maintenance messages Standard Engine run hours indication -h - Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) - - ---- -- - --- ---- - - ---- Uldity Voltage Loss/f3eturn to utili ad ustable(brownout se-thng)Y - From 140-171 V/1V _ ____— - --_ ty_1- -_ _ _ter _-- Future Set Capable Exerciser/Exercise Set Error warning Standard - --- - AuniAlarm/Nlauitenancelogs- __._ -__ _ __-__ _._ _ ___ �_.__ __ _.----------50 events each- "- -" _ ---------- - -------- - - — -- ---- - -- -- -- - -- ---- -------- -_ ------- - - -- Engine start sequence Cyclic cranking 16 sec on,7 rest(90 sec maximum duration) Starterlock-out , Starter_cannot re-engageuntill5sec_after engine has_stopped Smart Battery Charger — Standard w Ch — -- ----- ------- -_-__-.---- ----- - - — - --- ---- ---- --- — —- ---- ---- ar er FaulVMissm AC warmn -_---- -' --_9__ 9 Low Battery/Battery Problem Protection and Battery Condition indication_ Standard -- -- ---- AutomahcVollageRegulahonwdhOverandUnderVoltageProtection Under-Frequency/Overload/Stepper Overcurrent Protection Standard - --- -- --------- - - - ---- -- -- -- --- - -- -- ---- - - - --- -- - - rSafetyFusedlFuseProblem Protection ---__ ___- ___— - _— -_ tt �TStandard'-____ Automatic Low Oil Pressure/High Oil Temperature Shutdown _ _ _ _ _ _ _ _ Standard Ov - ecerank/0verspeed(@ 72 Nzj%rpm Sense Loss Shutdown _ ____ _ -_ -- J - ';; - f -Standard .-__ __JL - High Engine Temperature Shutdown Standard Internal FaultJlncorrect Wmng protection------_-..__ 1 -____ .--Standard __.__ Common external fault capability Standard Field upgradable firmware _ Standard `"Sound levels are taken from the front of the generator Sound levels taken other sides of the generator may be higher depending on installation parameters Rating definitions-Standby Applicable for supplying emergency power for the duration of the utility power outage No overload capability is available for this rating (All ratings in accordance with BS5514,IS03046 and DIN6271) 'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content,ambient temperature,altitude,engine power and condition,etc Maximum power decreases approximately 3 5%for each 1,000 It(304 8 m)above sea level,and also will decrease approximately 1%for each 10 IF(6'C)above 60`F(16'C) i7ENERAC 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features G007039-1,G007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware Model G007043-2,G007043-3(22 kW) _ G007210-1(24 kW) • Up to eight additional large(240 VAC)loads can be managed when used in conjunction No of poles^, w__ 2 ^I with Smart Management Modules(SMMs) - - .•-- ---_____. ___ -__. --- _ Current rating(amps) 200 • Electrically operated,mechanically-held contacts for fast,clean connections Voltage rating(VAC) 120/240,10 j • Main breakers are rated for 80%continuous load Utility voltage monitor(fixed)* -Pick-up 80% r • 2-pole,250 VAC contactors -Dropout 65% • Service equipment rated,dual coil design Return to Utility* Approx 13 sec • Rated for both aluminum and copper conductors ETL or UL listed Standard Enclosure type NEMANL 3_13 • Main contacts are silver plated or silver alloy to resist welding and sticking Circuit breaker protected - 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility Lug range - _ _ -250 MGM--#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly W, 200 Amps 120/240,1a Open Transition Service Rated Height Width Depth H1 H2 W1 W2 a in 268 301 105 135 69 cm 67 95 7643 2667 3418 175 " Wire Ranges S Conductor Lug Neutral Lug Ground Lug f 250 MCM-#6 350 MCM-#6 2/0-#14 DEPTH Ievz—I GENERACR 20/22/24 kW Available Accessories Model# Product Description i ! 000T01 0 __-;Batt(ry Pad Warmer - -ii-rid-w-a'r'm—er rests under the battery Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec-i !essary for use with AGM-style batteries) }§007102 0 Oil Warmer 'Oil warmer slips directly over the oil filter Recommended for use if temperature regularly falls below 0 IF(-18°C) 6007103-1 .Breather Warmer 'Breather warmer is for use in extreme cold weather applications For use with Evolution controllers only in climates where heavy icing occurs. ' 'GO05621-0 T 1 Auxiliary Transfer Switch _ The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be (Contact Kit {needed.Not compatible with 50 amp pre-wired switches i ,G007027-0-Bisque !Fascia Base Wrap Kit (The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured }(Standard on 22/24 kW) appearance as well as offering protection from rodents and Insects by covering the lifting holes located In the base. --Y - ____-__.._.._ .. -._ __ ,-..--_._ - ;§005703-0-Bisque ;Touch-Up Paint Kit _ {If_-the__generator_ enclosure---is__scratched_-_ or___damaged-_ ,itis-important_--to-touch__- up the paint to protect from future corrasion The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure iG600 485-01Scheduled Maintenance Kit }Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a. } Generac automatic standby generator(oil not Included) §007005-0-_ �'Wj-Fi LP Tank Fuel Level ;The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank Monitoring the }Monitor SLP tank's fuel level is an important step In verifying the generator is ready to run during an unexpected power failure Sta-; tus alerts are available through a free appllcabon to notify users when the LP tank is In need of a refill jG007000-0(50 amp)(Smart Management Module ;Smart Management Modules(SMM)are used to optimize the performance of a standby generator It manages large elec- IGO07006-0 Arical loads upon startup and sheds them to aid In recovery when overloaded In many cases,using SMM's can reduce 1100 amp) ! 'the overall size and cost of the system ies a - �___ Y the ; §007169-0--.4—GL-TE- Mobile Link Cellular :The Mobile Link family of Cellular Accessorllow users to monitor generator status from anywhere In world_usi , ng{ ;13007170-0-WI-Fi/ !Accessories la smart phone,tablet,or PC Easily access information such as the current operating status and maintenance alerts Us- ]Ethernet jers can connect an account with an authorized service dealer for fast,fnendly,and proactive service.With Mobile Link,i !users are taken care of before the next power outage (§007220-0-Bisque °Base Plug Kit _ Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured # appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base Kit { !contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC63761, 1218 mm ,251 A 1488,n1 G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727 5 n; G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 o a o 0 G007209-0 696471071511 - rT_ 11 G007210-1 696471084801 848 1232 [25 mm j25 S In; i48 5,n] LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate See installation manual for exact dimensions DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES G E 1 V E RAS ' Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com 02021 Generac Power Systems,Inc All rights reserved All specifications are subject to change without notice Part No A0000937814 Rev 0 04/14/2021