Loading...
HomeMy WebLinkAbout46111-Z �oo�gpFFO(,�cO Town of Southold 9/13/2021 � Gyp 0 P.O.Box 1179 o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42329 Date: 9/13/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1585 Long Creek Dr., Southold SCTM#: 473889 Sec/Block/Lot: 55.-7-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/1/2021 pursuant to which Building Permit No. 46111 dated 4/21/2021 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels on existing single family dwelling as applied for. The certificate is issued to Chasen,Philip&Lia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46111 5/5 021 PLUMBERS CERTIFICATION DATED I/.. A o ize S nature f, SufFe � TOWN OF SOUTHOLD BUILDING DEPARTMENT CA x TOWN CLERK'S OFFICE Woy�o ao� rSOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46111 Date: 4/21/2021 Permission is hereby granted to: Chasen, Philip 10 Sugar Toms Rdg East Norwich, NY 11732 To: Install roof mounted solar panels on existing single family dwelling as applied for. At premises located at: 1585 Long Creek Dr., Southold SCTM # 473889 Sec/Block/Lot# 55.-7-3 Pursuant to application dated 4/1/2021 and approved by the Building Inspector. To expire on 10/21/2022. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector ®��pF SOVj�®� Town Hall Annex a ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 c ® sean.devlina-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To. Philip Chasen Address: 1585 Long Creek Dr city Southold st: NY zip: 11971 Budding Permit#: 46111 Section: 55 Block: 7 Lot: 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GreenLogic License No. 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect r100A Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 12.96kW Roof Mounted PV Solar Energy System w/ (36) SPRx22-360 Panels Sun Power Monitoring System, AC Disconnect w/220x4 220x1 Notes: Solar Inspector Signature: w Date: May 5, 2021 S.Devlin-Cert Electrical Compliance Form As SOUTLf ,lI I r .J �� (fie, TOWN-OF SOUTHOLD BUILDING DEPT. `ycou765.1802 I-N SPECTION [ ] FOUNDATION 1ST J [ ] ROUGH PLBG. [ + ] FOUNDATION+2ND f -] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] =FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION " [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ G ] PRE C/O REMARKS: _ DATE � ..r12.4 INSPECTOR _ 5L'- q�M 11 SO(/T,��lo # # TOWN OF SOUTHOLD BUILDING DEPT. courm, 765-1802 - INSPECT-ION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [' ] FOUNDATION 2ND [ ] SUL-ATIrO_N/C/AULKING [ ] FRAMING /STRAPPING [ FINALSrQ'`U4 [ j FIREPLACE & CHIMNEY [ ]° FIRE-SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [' ] LECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ CODE VIOLATION [ ] PRE C/O REMARKS: ✓JCS `C (erv� Lrulf JA. ?rir , &AV D juk vyrM�+/ 11 rta vv , vi vo ID19 1w �- R) ty.L`' �i c` $ r r►v v —16. W pro `g`' _ o I "r vi✓ NVRti ,,ori ,b jwm i ,tom ` �c��'. Sri I�t�✓(�.� yr ' � '� on DATE INSPECTOR :11111 Fill III! III[ �1111 J A M E S J. S TOUT A R C H I T E C T & Assoc . 2 G REG L ANE E AST NORTHP0RT N. Y. 631 - 8 58 9388 Post Installation Letter May 3, 2021 RE: Chasen Residence 1585 Long Creek Drive Southold, NY 11971 To Whom It May Concern: This letter is to confirm that as of May 3, 20211, James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels. The solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2020 NYSRC and 2020 NYSUCS building code and provisions of ASCE 7-16. The installation was done as per plan. Thank you for your cooperation in this matter. James J. Stout Architect t i gED ARc 5_ MAY 1 7 2021 1 l' ESN FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) H ------------ ------------------------- FOUNDATION(2ND) z .T o ROUGH FRAMING& y 1 PLUMBING 1 (b TV y INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS \ 011 d C 0 c 2W °f �.a- �- C `��S -5 c iG S o 5f13- a) ::�54-A x /->- -4'�-x41•.,1 � z • Z r 1� Y, y �a ' TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 V Telephone (631) 765-1802 Fax (631) 765-9502 llfps://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT - - For Office Use Only � t . y . ��..� APR - � 2021 -.... PERMIT NO. Building Inspector ;�� •tag. : ��»� ,�� � ,� � � �� --y��;,;M��� ., , 'Applications anti forms must be;filled out m their entirety Incomplete '<"=�--' applications_vlilt:not be ac€opted. Where the-Appli ik,,is not the owner zari<- 'Ornrnet's Authbrizati+oh-fo ;(page 2)shall° e�carripleted., =o ,a�r-Y .y x P, = Date:3/30/2021 C?WNER 5c`-0 PROPER-- -, ""' '" �`- �= s =_i_ 2 ',,'P'�-,� _ xe 1y=`�s€tom Name:Philip„Chaser wk _a n SCTM#1000-55-7-3 Project Address:1585 Long, Creelc�ed, Southold Phone#:516-319-1612 Emai[ Philchase_n_@�gmail.com Mailing Address: CQNTPi�11'xP25t31V :; pa, .E �: �; iv ,s ;: : . M ice`=, .w Name:Barbara - GreenLogic LLCAw Mailing �.Address:97 North Sea Road,µSouthampton, W-1 1,19618 Phone#:631-771-5152 x117 Email:BarbaraC@Greenlogic.com m DESiGv4PROFESS3�sI<ONA INoaT!o'N 3i -�,,,W% -u,^a's�`=ik Name:James J. Stout Architect & Assoc. Mailing Address:2 Greg Lane, East Northport, NY 11731 Phone#:631-858-9388 w Email:stouthubjamesstoutarch.com :� «CONTRACTOR-1NFO)EtMATI(3N Name:FGreenLogicyLLC_____. m_ ____.__ _.__.v... _v..__.._. ....,...._ -v__ ._ _ .._ ..._ .. _.v..___..,_ -, _......_......__.. ._........_. __ Maung Address:97 North Sea Road,Southampton, NY 11968 Phone#:631-771-5152 Email: ciEscRa�Tl©lv, m �A�M@G_ re,enlogireck�.com -JPRtPomv_ 5E'DSTRU'ibz®F . _ ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other Solar Panels $42,000 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 FFOLtBUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD J C* Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 + Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(aD-southoldtownny.gov— seand(aD_southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: 3/30/2021 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: AM@Greenlogic.com Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance Address.: , 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Philip Chases Address: 1585 Long Creek Drive, Southold, NY 1971 Cross Street: Phone No.: 516-319-1612 Bldg.Permit litemail: Tax Map District: 1000 Section: 55 Block: 7 Lot: 3 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (36) SunPower SPR-X22-360-E-AC panels Et (36) SunPower SPR-X22-360-E-AC micro inverters (1) SunPower PVS6 monitor System Size: 12.960kW Check All That Apply: Is job ready for inspection?: DYES ENO ❑Rough In ❑✓ Final Do you need a Temp Certificate?: EYES ❑NO Issued On 3/30/2021 Temp Information: (All information required) Service Size E1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground [:]Overhead # Underground Laterals ❑1 ❑2 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION 'q ' �sL Electrical Inspection Form 2020.x1sx q L�Xlaf SUFFp�,I. BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD C= Town Hall Annex- 54375 Main Road - PO Box 1179 o _ Southold, New York 11971-0959 y p� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(a-),southoldtownny.gov-- seand a().southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 3/30/2021 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME email: AM@Greenlogic.com Phone No: 631-771-5152 ®krequest an email copy of Certificate of Compliance Address.: . 97 North Sea Road Southampton, NY 11968 JOB SITE INFORMATION (All Information Required) Name: Philip Chases Address: 1585 Long Creek Drive, Southold, NY 1971 Cross Street: Phone No.: 516-319-1612 Bldg.Permit#: email: Tax Map District: 1000 Section: 55 Block: 7 Lot: 3 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Roof mounted solar electric system (36) SunPower SPR-X22-360-E-AC panels Ft (36) SunPower SPR-X22-360-E-AC micro inverters (1) SunPower PVS6 monitor System Size:' 12.960kW Check All That Apply: Is job ready for inspection?: ❑YES [j?]NO ❑Rough In OFinal Do you need a Temp Certificate?: ZYES ❑NO Issued On 3/30/2021 Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground [—]Overhead # Underground Laterals ❑1 ❑2 ❑H Frame [—]Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION q �� Electrical Inspection Form 2020.x1sx PERMIT# Address: Switches Outlets G FI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments SURVEY OF PROPERTY N AT SOUTHOLD TOWN OF SOUTHOLD SUFFOLK COUNTY, N.Y. 1000-55-07-03 SCALE 1'-30 FEBRUARY 5, 1987 JULY 5, 1987 JULY 31, 2020 AUGUST 18, 2020 (10' CONTOUR) MARCH 1, 2021 (PROPOSED POOL) IN WOOD O0 SO.FT W � STEPS O'� LOT COVERAGE 0. RD O F RE7L4NDS LINEASOOD MFEN END 7.2W FEN.COR,' EVS77NG j WLF 0.9vHOUSE&PORCH 2380 sq.ft WOOD Wax GAZEBO 120 sq.ft 2 SHEDS 144 sq.f. fiJ / i DECK 436 sa.ft. LANDWARD EDGE OF TIDAL WETLANDS �� J� / J 3380 sq.ft AS DETERMINED BY SUFFOLK 4i i ip 3380/37,460= 9-OX ENVIRONMENTAL CONSULTING, INC. / V: ON JULY-21. 2020. -- ------- --------- O0, V., �COVEREID LOT 8 PROPOSED cs �/ i SWING HOUSE&PORCH 2380 sq.ft � / ' - ahh/ POOL 720 sq.ft. h / POOL SHED 112 sq.k. ems/ PROPOS GAZEBO 120 sq.ft of 10' 0 AT GRADE PAMO SHEDS 144 s k. 10' CONTOUR PROPOSED PROPOSED q SHED DECK �Sa•f1. LFA% GARDEN OBEDS FENCE COMPLIANT 24 2; 4212 sq.ft. /-' �pQ N/X 4212/37460= 11.2X SHED D.5'E \ � ----------------- FEN END 8.3 7t\ _ X� PROP05FD a+ /6`' j 1.4'W K SHEDS• ✓*._ 7 NE STEP 1 / P�� p� DW W 5� 2ND-FLP.HAMMY / $ J OVER DECK ��,�,� ARBOR OVER DECK PROPOSED SHED 3.3'E WOGA OZE"DBO lo, AVERS PECK i�i�,i 1i i —PROPANE POOL �„ TANK DRrwELI. SAUNA 4g1 1-1 o NRS / O FEN.CDR / FEN. 31.9 - 'Z / AROUND NORSE 3,7'W FEN CDR o/ POND 1_1/2 34„'1' x 0.714 / �=G rn 1O OSED 9' ° 310 jg 3' PROP / 21.3 OWOOD EQUIPMENT PORCH // 51 5 Be CURg ° mx f , �_ FEN.COR FEN END B 2.9'W . L J 3.7'E m° yi= nG m Va. ry GHT Q LIGHTfr POST ry POST Mx KEY o° 5�. Box •Q = REBAR �4Nh�ry C ® _ KELL V CMF .50 � = TEST HOLE 5538 � GRE�1c� DR,vE • - PIPE .0,90 ■ = MONUMENT = WETLAND FLAG rO..) = U77UTY POLE ELEVA77ONS REFERENCED TO NGVD 29 CERTIFIED TO: LOT NUMBERS REFER TO SUBDIVISION MAP OF LONG POND ESTATES- PHILIP CHASEN SEC. ONE"FILED 1N THE SUFFOLK COUNTY CLERK'S OFFICE ON DECEMBER LIA CHASEN 27, 1985 AS FILE Na 8037. ANY AL7ERA77ON OR ADD17ION TO 7HIS SURVEY IS A VIOLA 770N OF N.Y,S. LIC NO. 49618 SECTION 7209 OF 7HE NEW YORK STATE EDUCA77ON LAW. EXCEPT PECONIC SURVEYORS, P.C. AS PER SECTION 7209-SUBDIWSION 2 ALL CER T7F7CA77ONS HEREON (631) 765-5020 FAX (631) 765-1797 ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF SAID MAP AREA= 38,242 SO. FT. P.O. BOX 909 OR COPIES SIGNATURE BEARAPPETHE IMPEL SEAL OF THE SURVEYOR IWOSE TO TIE LINE 1230 TRAVELER STREET SOUTHOLD, MY 11971 8�-1c�2 E EE LOGICO ENERGY March 30, 2021 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Project Info: Philip Chasen 1585 Long Creek Road Southold, NY 1000-55-7-3 Dear Building Inspector: Please find attached a building permit application to install a roof mounted solar photovoltaic(PV) electric system for the above referenced property. In connection with this application, please find attached: • Building Permit application with owner authorization • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, Xwd6 caewcck*a Barbara Casciotta Account Manager Barbara@Greenlogic.com GREENClICr111C5,1te t efiggic.com Tel. 631.771.5152 Fax- 631 7715156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGIC" ENERGY May 13, 2021 V The Town of Southold MAY 1 7 2021 Building Department 54375 Route 25F- mr,11 WIr P.O. Box 1179 71 Southold, NY 11971 0 Project Info: Building Permit No. 46111 Philip Chasen 1485 Long Creek Drive Southold, NY To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you have any questions about the installation. Sincerely, Mavbz=exociotta Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC -www.GreenLogic.com Tel 631 771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 AC V• CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) u' 01/29/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES I BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske Brookhaven Agency,Inc. PHONE 631 9414113 FAX 631 941-4405 100 Oakland Ave,Ste 1 EMAIL . Certificates@ brookhavena enc .com Port Jefferson,NY 11777 INSURERS AFFORDING COVERAGE MAIC# INSURER A:Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLC INSURER C. First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D:National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSRTYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXPLTR N /YYYY1 LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE X❑OCCUR DAMAGE TO RENTED $100,000 X Contractual Liability X X GL202100012922 01/31/2021 01/31/2022 MED EXP(Any oneperson) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $2,000,000 POLICY®JEST F LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000,000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2020 08/11/2021 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ X AUTOS ONLY X AUTOS ONLY (Per acrident) UMBRELLA LIAB HOCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STA Tr FIR ANY PROPRIETORIPARTNER/EXECUTIVE E L EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? 11 N/A see seperate certificate (Mandatory in NH) EL DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $ C NYS Disability D251202 04/11/20 04/11121 Statutory Limits E Installation Floater/Property SML93076366 4/15120 4115/21 $300,000 $2,500 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> AL4 01988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD YORK CERTIFICATE OF STATE =nsatlon NYSWORKERS' COMPENSATION INSURANCE COVERAGE la.Legal Name&Address of insured(use street address only] 1 b.Business Telephone Number of insured j Greens,gic LLC, 631-771-5152 97 North Sea Rd Suite 3 1 c NYS Unemployment Insurance Employer Registration Number of South Hampton,NY 11968 Insured Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or,Soraal Security certain locations in New York State,ie.,a Wisp-Up Policy) Number 203801194 2.Name and Address of Entity Requesting,Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as,the Certificate Holder) United Wisconsin insurance Company Town of Southold Building Department 3b.Policy Number of Entity Listed in Box"1a" 53095 Rte 25 WC532-00243-020-SZ Southold,NY 11971, 3c Policy effective period 7/23/2020 to 7123/2021 3d.The Proprietor,Partners or Executive Officers are included.,(Only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"'insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of insurance to the entity listed abov&as the certificate holder in box"2'„ The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the-policy or eliminate the insured from the.coverage indicated on this Certificate.(These'notices maybe sent by regular mail.)Otherwise,this Certificate is valid for one year after this form,is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box-!'3c'!,whichever is earlier. This certificate is issued asa matter of information only and confers no rights upon the certificate holder.This certificate does not,amend, extend or alter the coverage afforded by the policy listed„nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,'if the business continues to be named on a permit,license or contract issued by a Certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements-of the New,York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized,representative or'licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this-form. Approved by: Alicia-Christiansen (Print nam onzed representative or licensed agent of insurance tamer) Approved by- NRIATWUM 1:121 (Signature) (Date) Title:Assistant Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier. 941-306-3077 Please Note:Only insurance carriers and their licensed agents are authorized to issue gorm.C-105.2.insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov i Y� Workers• CERTIFICATE OF INSURANCE COVERAGE srA7E Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART1.To be completed by Disability and Paid Family Leave Benefits Carrier or licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured GREENLOGIC,LLC '631-941-4113 97 NORTH SEA ROAD,SUITE 3 SOUTHAMPTON,NY 11968 ic.Federal Employer identification Number of Insured' Work Location Of Insured(Onlyrequtredrlcoverage isspedficallyitmrfedto or Social Security Number certain locations in New York State,i.e.,Wrap-Up Policy) 203801194 " 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) SheiterPoint Life Insurance Company Town of Southold 53095 Route'25 3b.Policy Number of.Entity Listed in Box"1a" Southold NY 11971 DOL251202 3c,Policy effective period 04/11/2020 to 04/1012021 4. Policy provides the following benefits: ® A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. `5. Policy,covers: ® A.All of the employer's employees eligiblevnder the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above�and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. ; Date Signed 4/13/2020 By. J'� � (Signature of insurance carrier's authorized representative or NYS Licensed insurance Agent of that'msurance carrier) Telephone Number 516-829-8100 Name and Title Richard White Chief Executive Officer IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or,NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 413,40 or 56 is checked,this certificate is NOT COMPLETE for.purposes of Section 220,Sub'd.8 of the NYS Disability and Paid Family Leave Benefits Law.It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200,Binghamton,NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box•4C or 5B of Part X has been chacked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with 'respect to all of his/her employees. Date Signed By (Signature or Authorized NYS Workers'compensation Board Employee) i Telephone Number Name,and Title Please Note:Only insurance caniers licensed to write NYS,disability acid pall Family leave benefits insurance policies and NYS licensed insurance agents ofthose insurance carriers aire authorized to issue Form DB-920,1.Insurance brokers are Norauthorfxed to Issue this form. x DB-120.1 (10-17) � 1�DB-120. (10-17)�r l k < 'i s ��-�'� .: \`,1 j ,:r� ��/ .fit /j ;;< r�' _.F<. 1� `/ - r� � ��: .'1`,// ;_, \��%/ � �\ /;.: �(r`'- � \\r/ r� ,� -.•�+•!/ -�, ' � ��i CLr �� r�/I fit, �'�N. � L'��1 �t�/� � ✓> \� ���t�i _��� q i' 't1• J J.. f�l I _ y � i )���' 1 • r/ I�j�4v r �. 'k a Suffolk County Executive's Office of Consumer Aff irs &F V VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 DATE ISSUED: 5/25/2006 No. 40227-H ? Home Improvement Contractor License This is to certifv that . .... MARC A CLEAN doing business as GREEN LOGIC LLC having fumished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses NOT VALID WITHOUT AND A CURRENT CONSUNIER AFFAIRS ID CARD Director ANE1 en N A 0 A it ,u I , J A M E S J. S T 0 U R C H I T E C T & ASSOC . 2 G REG L ANE E AST N:oIR' THP0RTN. Y. 631 — 8 58 9388 Letter of Certification March 24, 2021 RE: Chasen Residence 1585 Long Creek Drive Southold, NY 11971 To Whom it may concern: I, James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 130-mph wind design load as per 2020 Residential code of NYS (RCNYS), 2020 building code of NYS (BCNYS) residential code, 2020 Energy conservation construction code of NYS (ECCCNYS) and the 2017 National Electric Code NFPA 70/2017 National Electric Code, and the ASCE 7-16. The existing 2"x 6"@ 16"o.c. roof rafters will provide adequate support. Thank you for your understanding in this matter. James J. Stout Architect APPROVED AS NOTED DATE:-4.La B.P.# �N CO . L`l WITH ALL CODES OF FEE:o?o� - BY: � MEW RK STATE & TOWN CODES NOTIFY BUILDING DEPARTMENT AT S RE IRED AND CONDITIONS OF ED ARC, 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: VTHOLD TOWN ZBA - �<v� �G� �` 1. FOUNDATION - T O REQUIRED TOWN PLANNING BOA FOR POURED CONCRETE 2. DOUGH - FRAMING & PLUMBING TOWN TRUSTEES 3. INSULATION 4. FINAL - CO��iSTRUCTION MUST . . yT 0 1633 �OQ� BE COMPLETE SCR C. _ p NEN ALL CONSTRUCTION SHALL MEET-THE REQUIREMENTS OF THE CODES OF NE PANCY OR IN YORK STATE. NOT RESPONSIBLE FOR 9S UNLAWFUL DESIGN OR CONSTRUCTION ERRORS. Vd,TOUT CERTIFICATE U N U N - TYON REQUMM GREENLMOCO ENERGY GreenLogic,LLC Approved Chasen,Philip 1585 Long Creek Drive Southold,NY 11971 Surface#A: Total System Size: 12.960kW Array Size:2.880kW 1 circuit of 8 on a 20A breaker Azimuth:160° Pitch: 10° Monitoring System: SunPower _______ Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8" Surface:23'X 9' Magic#:Invisimount Legend: ® 8 SunPower 360W Panels ® SunPower Invisimount Rail i 20 Quick Mount E Lag 8 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: ,ED Ah'c i 1 X21633 ' OO OF N E� Drawn By:MA Drawing#1 of 8 Date:3/22/2021 REV:A Drawing Sceie:1/4"=1.0' ff -ENLO V ENERGY GreenLogic,LLC Approved Chasen,Philip 1585 Long Creek Drive Southold,NY 11971 Surface#A: Total System Size: 12.960kW Array Size:2.880kW 1 circuit of 8 on a 20A breaker Azimuth:160° Pitch:10° Monitoring System: N SunPower ••-- ........ ........ ........ ........ ........ --•----- ......... ........ ......... Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8° Surface:23'X 9' Magic#:Invisimount Legend: ® 8 SunPower 360W Panels ® SunPower Invisimount Rail • 20 Quick Mount E Lag 8 B 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: ED Rc Gv��S S 0 /Ate dues )� �2 633 Drawn By: mg#2 of 8 Date:3/22/2021 REV:A Drawing Scale: 1/4"=1.0' �..__,,� ENERGY GreenLogic,LLC Approved Chasen,Philip 1585 Long Creek Drive Southold,NY 11971 Surface#A: Total System Size:12.960kW Array Size:2.880kW 1 circuit of 8 on a 20A breaker Azimuth: 160° Pitch: 10" Monitoring System: N SunPower .............•-------------------•••-•••-•......--•--•---••••--• Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8" 1 Surface:23'X 9' Magic#:Invisimount Legend: ® 8 SunPower 360W Panels — SunPower Invisimount Rad 1 ! 20 Quick Mount E Lag 99 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seat: RE ARO �j '9 1633 F NON Drawn By:MA _ rawing#3 of 8 Date:3/22/2021 1 REV:A Drawing Scale: 1/4"=1.0' U I ® ENERGY GreenLogic,LLC Approved Chasen,Philip 1585 Long Creek Drive Southold,NY 11971 Surface#B: Total System Size: 12.960kW Array Size:10.080kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:340° Pitch: 15° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:38'4 1/2"X 15'5 5/8" Surface:41'4"X 19'2" Magic#:Invisimount Legend: ° ® 28 SunPower 360W Panels x X N SunPower Invisimount Rail • 50 Quick Mount E Lag 8 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: A%y p4 d OF NES Drawn By:MA wing#4 of 8 Date:3/22/2021 I REV:A Drawing Scale: 1/8"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Chasen,Philip 1585 Long Creek Drive Southold,NY 11971 Surface#B: Total System Size: 12.960kW Array Size:10.080kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:340° Pitch:15" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:38'4 1/2"X 15'5 5/8" YA V Surface:41'4!'X 19'Z' Magic#:Invisimount Legend: ® ' 28 SunPower 360W Panels MIT - Jul SunPower Invisimount Rail • 50 Quick Mount E Lag VK B B 2x8"Douglas Fir Rafter 16"O.C. Notes. Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: RED ARc j s,oGtii�� . evv N aoum '9 X21633 OQ" F N E\ Drawn By:MA rawing#5 of 8 Date:3/22/2021 REV:A Drawing Scale: 1/8"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Chasen,Philip 1585 Long Creek Drive Southold,NY 11971 Surface#B: Total System Size:12.960kW Array Size: 10.080kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:340° Pitch:15° 15—Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-E-AC Racking:SunPower InAsimount Panel:61.39"X 41.18" 2 Surface:41'4"X 19'2" 4 Magic#:Invisimount Legend: ° I ; ® 28 SunPower 360W Panels 2 3 4 SunPower Invisimount Rail 7 7NO'C7 -�k �V & - • 50 Quids Mount E Lag 8 2x8"Douglas Fir Rafter 16"O.C. 3 4 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quids Mount,SunPower Added Roof load of PV System:2.84psF Engineer/Architect Seal: D ARC - � a �-9 21633 OF NE�`l Drawn By:MAcawing#6 of 8 Date:3/22/2021 1 REV:A Drawing Scale: 1/8"=1.0' No Vent Pipes Will Be Covered By The solar Array G R E E N LOS 0V ENERGY Legend: GreenLogia,LLC Approved Chasen,Philip AR-Access Roof AP-Access pathway,36" minimum width SVO—Setback at ridge 1585 Long Creek Drive per R202 definitions per R324.6.1 as per R324.6.2.1 Southold,NY 11971 Total System Size: 12.960kW 1 circuit of 8 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 dreuEt of 9 on a 20A breaker 1 circuit of 10 on a 20A breaker Azimuth:160° Monitoring System: N SunPower Panel/Array Specifications: 28 SunPower Panel:SPR-X22-360-E-AC 36OW Panels Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:39'7"X 35'3" Surface:79'9"X 36'9" Magic#:Invisimount XIX xLegend: NYA. I 571 36 SunPower 360W Panels o� IAP o SunPower Invisimount Rail I I • 70 Quick Mount E Lag D NWV I p B 2x6"Douglas Fir Rafter 16"O.C. --°— ----- -- ----.av4---- -------- —1 0o 2x8"Douglas Fir Rafter 16"O.C. 1 I I ---_-syLo_--_ —— Notes: lCn oI Number of Roof Layers:1 �o Height above Roof Surface:4" I I ............. ................ Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf En eer/Architect Seal: mg, i0l ® RC 5� S S 8 SunPower Meter � , 36OW Paned `p Jq 0 633 _ Oo F F NE`s Drawn By:MA Drawing#7 of 8" Date:3/22/2021 REV:A Drawing Scale:1/16"=1.0' (��<�-\GREENLOGIC@ ENERGY GreenLogic,LLC Approved Chasen,Philip 1585 Long Creek Drive w---- r Southold,NY 11971 JOB MATERIAL LIST ' Total System Size 12.960kW 1 circuit f 8 on a 20A breaker a f i i j 1 circuit of 9 on a 20A breaker __. 1 circuit of 10 on a 20A breaker + Azimuth:160' - Material List--" Q I Rail Material List y Monitoring System: SunPower Panel/Array Specfficabons• Panel:SPR-X22-360-E-AC Cast Aluminum Mounting Block w/Black Aluminum_ Flashing 70 : ; Racking:SunPower Invisimount 5/16"x7/8"EPDM Sealing Plug 70 _. Panel:61.39"X 41.18"Array:39'7"X 35'3" ` 5/16" 5��. x5Hex Head Lag Screw 70 i Surface:79'9"X 36'9" 5/16'x1.15"Fender Washer -70 `. ._.- ,. Magic#:Invisimount - - { Legend: 36 SunPower 360W Panels i o SunPower Invisimount Rail ' _.. _-•- __--- i , _ _ _ •._.___. _____-. ____- -- ---,-____-- ,---_-, - �-- _-- _-- _ _,-- _ - -_-i-- - 0 70 Quick Mount E Lag i ._- _ _ 8 2x6"Douglas Fir Rafter 16"O.C. 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:2.84psf Engineer/Architect Seal: o qRc C-1 ` `y9 0 163'3 0 OF NES Drawn By:MA Drawing#8 of 8 Date:3/22/2021 1 REV:A Drawing Scale:1/16"=1.0' :t NEW EQUIPMENT — - — — FXI.STING SERVICF i s PV-SA-1 zcoA 1 I'"--" - AC-COMBINER PANEL { PV-SA-1 AC--0140--1 i (AV LCrSDS ONLY) AC DISCONNECT ( `� d 0 © A(-CTSC-9 t ► ► ► 1 I3 I P e e a � PV-SA-3 ' I I ffFUSED I WIN ® • • • ® e DKR-2 t� I • • a 2 1 I eV B BI FUSED A 8 N I t1Kft-3 t I EG4 I II III N I � N EGG EXISTING AC PANEL n ., _--___ EXISTING j °E .-___I• GEC IRRLVERS€QLE SPLICE- � � � � �6 CU PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Chasen, PhilipGREENLOGIC 1585 Long Creek Drive r ENERGY Southold, NY 11971 ELIMINATING THE, COST OF ENERG" 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Chasen-3LD1 Revision: 1 Revised: 2/22/21 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 12-MODULES PV-SA-2 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 12-MODULES PV-SA-3 PV SUB-ARRAY SPR-X22-360-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 12-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 4320 WATTS 211-264 VAC 17.56 A AC 240 V,AC PV-SA-2 4320 WATTS 211-264 VAC 17.56 A AC 240 V,AC PV-SA-3 4320 WATTS 211-264 VAC 17.56 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Chasen, Philip vGREENLOGICO 1585 Long Creek Drive F ENERGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1 ) INITIAL SUBMITTAL WITH APPLICATION tPage 2 of 3 Drawing No: Chasen-3LD1 Revision: 1 Revised: 2/22/21 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, 100A, NEMA-1, FUSED; FUSE RATING: 100A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 1-1/2" PVC-40 4 / 4 C THWN-2 1-1/2" EMT 4 / 4 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER MINIMUM. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Chasen, Philip �<�� , 1585 Long Creek Drive , N ERG Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Chasen-3LD1 Revision: 1 Revised: 2/22/21 ?�«r,e N�', •,Y„ ,� ''r�'�'; "".t:. 'i.'' �_ ';;r,,,,,,�wa't' �"�i,g��,'�„;^�0°®�"�a,�.�'.;:.<o��z.at��;�''�",tRy',�°.„a,�-.a«y,,x,,3,,.,�k��'�wk���''�:`�CF{�3',',�", ,'We"r,;»,a a il;yi"•�"33ry��,y^cW,i ai''��..;�''_%,r�''",�.�„���x,�, ro_«�.'�n?�`'L«aaaq,2;y�J�,",„,�»„)„'.�!'���',,',z`�'"'”:,.��°�N;�;,.��,�,,auy,rr��a�',",�t£c"_'1r,W.,,..tm.,�,„�;a�°�s'ra�Jars.�'�;t,�,r,,�,,,•<.�i,;,y 3��£.r�"�v�xaM,t�"a{.,�'i�''`�Aav`,�.+,,ma,1�si-,.`�8a y,.,,aa.�,mssa,'�,„�.m-.;'HY,,'i/,.w"nr�.>,'�az-',"�,'•yp'.,»�,,"�y'.,i",„.,r`'<, ,s +y"id'ra"y Yn",sa' `irr,,°�I.'��4k"r;�'.� ; "'i,r,.rf;Z . .§>s1 'Vp � '�.;�.}• "..,'�'P1' MEMO YiYtt ,�vw -ter R%�s�' ;�-`�' z h :ya\,�ra �" ;��;� ��.,, ”"CsfsJ, �-x-•"" r,,��-��>,rFsa,»r « � •? « � ffi (JOdt,e*i(v1 cl C10rnp c^rl Ra, fAc'Jex i End Ckamp umd Ra,l �a Mic1 r arr0 int+c larrn <all Ec Ra,Spire G,ou-d Lug Aq;Frroly i nd Cap Component (v`ar WFight LFeniaerature 40' <} C r0 90'C( __to'9,- f) erica ---- MFx L,-)aa(I RFD) 3000 F'a,Jp6R MIC Clamp E3'acK oxice s:ainiess-'.ec AISI 504 6."3 g(2 2 oz'. 60Ub?a dov,rion e -- End Clam p B ack anodized aluminurn alloy 5053 Tui 110 g(3 88 oz) i Rad B-aCK anodized alums 0..m ally ,JOS l6 i 830 On(')oz:Ft) � i Rad Splice Aluminum alloy 6005 T5 830 g/r,",'9 02:=1) 25 yrar prod1,ct✓var,,D i Grc?t_ir a ug - i0 t tain,ess ----- War,ar,ves I Asserroly (A1_-70 bo t,.r,-p ate c corner ill'r1 i 1 ric ghT (3 75 or) 5-year fmosn:warranty f- ------- --------------------------—.... --- — ---- --- - ------ - - - - --- End Car f ack aceta)(t'0,M)cor0 ymer I C&g(0 47 07) - -- - - - =--- -- UL_703 ,_ted Ce-eficatlons MAID C as,A Fire Rated ' ------- -- ----- ---- ------ ---- --- -- - - - . r nrz;i0;ron_:h,nglF RafterA.tachrrer. n i Aoplica-ion Ccirno,is,.ivn Sil,rl,.;ho ,Rof�eL,ar,g Attariirlent Curved ar,ci"wt T,le RtwFAuaCiir;en: I Ur,,%e•sai Interface`or other Roof ArtaL'iments Re`er ro oof at:azh,ne-ir han.v.,are manu`aCn''ors c 0c mentaticr I "Jo c,llr'rame rnar camps;b,-r•:h the fnv Si P;awnt systo— equireci€or ha ,yII e Interoperai,iIity ? 'S 5"iRivver:cr t era;on kIi Rtg itS P,e e`vnd Stlyagv1 R,rh:YJNPGL"J-R Ir, :, rd i d 151r°,it:VT re tr�:n 3r S o refit>te-d ti<:^^marKsof:rirGowrrCorfxr:o'i x,othe•:ad�mzrk s etl p rp�ityofthornrerpe;'vecr: er; sunpova-i rwn soecitcabrrs irrltjdAd it-nis Oata;he:r nre sub,c•r-,to cnznge vitho-;notice Document#509506 RevC W 12 -Simple and Fast Installation Z7 lr�l mod ili grounc ng Pre-a—'emblect-i-id and end .-lam os LeViiating mid n6rnp for ea plaitli Mid clamp widi',h ral 6onslstei rriodu'le spa,,iris "1 9- Sirripli pri illod,rail snh 270-A Usti' ated nu-9r Ic F xible Desigr, AddIresses=iearly rill slooc-rc.s'dcrtial-rcofis Design in Lmidscdpe 3rid,`pdr,rah Rails erJb�lr',Cjsy 6b,io'cle' r'T'iai,dgernl Custot-,ner-Prererred,Aesth�tics ...... Best-ir:-1 syste alcs Flegant Simolicity c Prrniurn,low-,profflo desi�,r B.a-k anodizec-omponents' visiMoi is a S-nPower-designed c SunPovve,� In 'Hidder m d clamps and i A camps rail-based mount-rig system The Invi-):Mi system and cappeo,flusri 4's addresses -esidi sloped roofsa-d combines. aster ?f S Peri ..r Part u b �System i-sual-ation time, flexibility, and superior aesthetics. Bolt for use'Wtn SurPc,,ve,DC and AC'ml The InvisiMi proi was spec,f ically envis,oned o,,d _Bes -in-class sy:,tei­relfab(lity,and a6s,lheus- --)m'ine vvr -n6di he r s,iltir engineered to pair wi[h SunPlcrivver modules. f e L Ig C( 0 SunPov%,e�i -,s an rf -Moniforir-a"rp amplify the aesthetic a-d sys[erTI-leve: approach will arr l-s[al'ation ber-efiFls for both homeowners and installers. .-s A, sunpower.com X SUNPW ERO ` j" Sun Power" -Series: X22-37I X22-360 t SunPower" Residential AC Module Built specifically for use with the SunPower EquinOXT11 system,the only fully ,;-- integrated solution designed,engineered,and warranted by one manufacturer. Maximum Power. Minimalist Design. y� industry-leading efficiency­jeans more power and savings JYper availaole space With feeA er modules required anc hidden microinverters,less is tr_!y more Highest Lifetime Energy and Savings. Designed to deliver 60"more energy over 25 years in real-world conditions like partial shade and high temperatures' 'F,undam' epntaIly,TDi f` :; -------------- r"p11��1` e�tLr,.. !up to w` d 60% ;more lifetime Illi .kin K' 3,.. �.a, �.° '<,t �,�,., '°rq ,,. r-� _ � • �> ��,'; �.���t' ° energy inN u:jheSunPo4wer-*ma"xe6i i—Solar:Celh _ .,. < r :xx<,'' Years of operation Eriab` `hialiesa-0 idency`yx' ' iroades ava%a.1- ,s Best Reliability. Best Warranty. •% Paten.er.sol,d neral-fbe:ncfaUon' st�r2c%e<<s`k;�ea age arioc i�r s3c�i..a � �� With mo-e than 25 million modules deployed arourd ' the work,SinPower technolcw is proven to last.That`s why we stand behino our module and rnicroinverter with the industry's oest 2.5-year Combined Power a'id Product Warranty,mcluding the highest Pcwer Warranty in solar '°Facto`ry-integratecltviicroiriverter` `�Y'' co� •, simb1 ,fasteer jnstl,lat or c ups 17',•` In /a ;,�,� g<,ir �' ,G.3J(d<w�t1Jt:�0'vvn�< w���,cy;,- ;.rr:`. a •rL4 °,,,,�'«°` <='``�°� �-, q ,s, B •,X' <.�<� r�ca'ih?ated`t;y..�''°` E "os > 121a Engin ��ea':i �<�, r " more ' SuriPo;^�Gr,';(JYes.Ji'v�''OG•it;;t7"�d:..l`25<,'s," r F;',- i m,r`,�`'-` a power fi �n y i L` - �it•t -�`: < 'PYk.S a m ..tea-y '. .5 _... _ ..v.x......>. .... .�.<..:.n r..... ^K�` «..,. .. ..... -t3 Y 8<5i V.�. �i�e"a�l"�',,,kAe<.'<gisr•dd zrda�'e`., °p .>�,', F '.' .yg��„N ear �� >e. a ,,R; %r„ •.' ems, 25 Years of operation ®. X-Series:X22-370 ! X22-360 SunPower"Re-sidential AC Module 71rt,rMode!.Enphase IC)7XS QQ)iS 96 ACM US) C?240 VAC 0208 V,AC nu-moo,,.,,+er-- 32C:-„ 320 b'A t rlUGU=GJCUU. 1'15 VA Num (L L)':oiras;r/f:,:nge`tV; 1'4012"-161 08/183-21c) ---- ----------- ----------- --- -------- -- - ------ ----- - - -------------- - - `•,x Cor;: v_ic_s Outuu:C, r+nr(A) 1 31 1 51 Ma Uni s r er 20 A(L U,G a'cF C ircur,' - -- --- "2(s,i ize phase) 10(two Ocie)vrye - - ;t C ij;nt. rff,f lEt Cy - '_— -- ---- --- ----9/ .00-- -- - - - -- 91'0?%� ^fort Freq.erg/ 60 Fig ------- - ------- ------- - -- - ---------------------- ---- --- Jte-,deo fcquerG 47 681-17 -- --- ------ - -- --- ------- --- - --- ---- - --------- -- AC oft C +jr I atPt Ct'r-ert()'Jai-7:yrs^s 3 A i is Qv�fVOi.: ._I=.S:,,._{'G': A�ac•t G '{[c;n Cu'r,r. 18 mA "w,C'I atr _e(tinR - - 1 0 ,vr Facur (ad)j__•;n e) 0'lead r u J` ag ------ .....- -- P,c ac.ve rh,,se oah+r-ng fcr:roe p-as,ulsta lar ons -- --- _ SPR-X22-370-E-AC SPR-X22-360-E-AC ;._ 25-;ear i rnrea;sower v,+arrant'y c ranues Nominal POAei'(Pnorn; 370 W 360 VV --- 2ti/ear i mi pro;uct'•raarranty --- - °ower iclerance -- -t-Oyb -- - - /-OSu UL 1703 LIL Certi'icancns "7-1 /'EFE-1547 ',Ao-ule Effaency' 227V, 221% ---� LA_`74''AC'vlod,ile(Type 2 r'e ated) - --� and Ternp Co,,[ (Power) - 0 29%/'C -- -r,294o/'C Cerroliance L,L 62109-1 ;TC 62'09?_ ;- -- -- ----- - -- — FCCParL15CA-,R -hree hy'na«oiodFs I ICES 0003 Class 3 i Shade Tolerance ntegrated module-leve n a>iniutrt CAN/CSA C222 NO 107 1-01 -outer po nt tracking CA Rale 21 tUL 1741 SA)' - ;includes Vo't/Vor arc!Reactive rower Pr on cy`, ® � - • ° ° UL Listed I?V Ruoid Shutdct^.'n Equ Pmer-" Oaerai€ne'emp -40'F to- 40°F(-40°C-o GG°Cl ,_noble,instali,a on in aci or,^,ancevrttn Hax Ambien:Temp 1?2°F(50°Cl •NEC 690 6(r`C niodU12) Load Wird 62 Psf,3060 Pa,305 k;1/r1 front&hack h'FC690 I7 Rcoid Shutdown Onside a d outside the a€ra Iv1a3y) ! X ' snow ?',asf,(,000 Pa 611 kglm' rent NEC 690 1 AC Conneczans,690 33(A)-(E)(") -11 no "esisarnce 1 Inca(25 i m)d,cmeter hail at 52 n-Dh t23 m/s) --- -alien ised with;If'•nsiMoLm r ick ng and Irv,siNlourt accessories p„ (UL 2703) So ar CPbs :G vlano^�•^talline P.4axecn CPn III Iv odu e grct nc ing snd bond€^,through lrfmsiMount - -- - - - --- - A fire i sled Freta Glrss Nigh-lrar.%nriss,on tempered glass t:^t^ tai hen used vnth AC€module Q Cables and acre=sones(UL 6703 and antrrefec:n=e i a.Jnn� U_2235' i L eek Envirau-,entRazed fol slRating i4lodu!e Outdeai ratan __--- _'oaJ disco -- Inv:•€t°>r NEVA ( PID , i ,ent a[induc2ci degi acla:ior free Tv,P 6.I=i�S II 7^1-esr o ' Frame Class 1 black anodized("ghest AAN A rating) -- ---- _—_____ __ ,,,,� _ _ 3556 snm•tat 3 Weigh: 42 9 Ib 1.9 5 kg) Recommended Ivl„x 1 3 1 (33 rrrn) h,oduleSpacing - - --- -- _ 1 at nlsove'3E0 W compare;!to:convention'i module cr same- led anLys(L.,O ih•,154', (a,�m3 ef5oe•rt,df.prox`Grr/},d:1'^-rtuee•,n,gyperv:a.,{tra5ec'aut-wd-Narri'-,o.ft=e cnar.,clenzatronardNJSimi,074'r%y=sio.re•degtada;icr(Ca-rraeau,Z,e.v "Sun>'cr.�'e, '� 1 t'a:tule Ge adaLan R;,e,`San>>o vel rata€;e,::pet,2073) o sn.:&men "'_'_"""' i Edsed'Jrt,ea ch,fda: r ieefv:;uesfrorn',veb,itestitvi>",.iraru;ac,,,rer seri �..r•.of tstairs} m Ja nu.i,y 201; (1 2+e f 3 t=1 rdnl in'rrd n•ru e1' 'VCt'a ylni,a,vafcr;clar •Jviu es Part 3`PVirch-ower } C1a,7tne,201S.CarnpEau,Z eta! S.=rf'ov,e LioduleJegradat.onRate,Sor•Povaer•x'ute paper,2013 373 4factoryse,to`;`41a-,r`-.e'aul;sel,n,sCARule 21 defaultse,tingsp'ofesetdunng (tsssrl comrnissicr'ng See;heEclu'nox nstalhUcnt.nce*=5 8 01`o'rnoremformotion SStanddreiTestCo'idnlons;JOCC J,rn'i radian=_e,4Mt�,25`Q NRL-Lcail)rA,on standard SO'.95currenl,Lw:CSti =at[=,ci;age AJDC•voitage sfjIfyc:)ntairacr:ithintf,e module , n37,rni 6,his prco xi.is LJL Lister as P VRSE anc m^`orrns with NEC 2014 and NEC 2017 690 12, mu In.) ano C22.i-��)1��>ule Gv-L7 a tantci�h,ttcioYvn off>V Syste•ns,f>r A�acid C:ccr ducto's, +rlhe'i installed d ccordirg to=eta=uifacu•ccs mstrt.ctions u.,.roDnc U ca�aivr>'xrvx� NRRu.-f,E //p��\ UN r �wl� SCC rnorede,ads,s,-.'metre fcrmorerefe'nr s moo,rmction O }RAFD•l3AEGMiN / �� I of mare 4e�ails,r.e axtrrred datashee;4::^ta z tnacss=er ccm;datasnee:s �{ly/(y`7y(y spi�nl„at,ons imudec it:his datashee:z:>u.1Jo;r ru chance without no-:c LISTED Ed—o '201 p SunPow=e=Corpvati in n I Right,Re,e,v>,cl SUNPOWER, he rmduie r, eero ranca Type 2 5JNNt'JATRlc�1, nc R'AXCCs:are,revver^n tiadJ marks c-SimPol:ei Plerse€eau the SGfe.`slid in,tai d.3n ns,rurt ons to >_tai s 531945 RCVA Comcretuon it-h«•lJ,a'id o-her countries as o ell 1 890-S'NPOW.-N