Loading...
HomeMy WebLinkAbout45677-Z �o�OSU�F� pG Town of Southold 8/19/2021 o - P.O.Box 1179 C" • 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42250 Date: 8/19/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1680 Westview Dr,Mattituck SCTM#: 473889 Sec/Block/Lot: 107.-7-19 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/31/2020 pursuant to which Building Permit No. 45677 dated 1/13/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels as applied for. The certificate is issued to Orlowski,Steven&Ano. of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45677 5/4/2021 PLUMBERS CERTIFICATION DATED Aze 'gnature o e SUEFvt,�c TOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE oo�4F SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45677 Date: 1/13/2021 Permission is hereby granted to: Orlowski, Steven & Ano. 1680 Westview Dr Mattituck, NY 11952 To: install roof-mounted solar panels as applied for. At premises located at: 1680 Westview Dr, Mattituck SCTM # 473889 Sec/Block/Lot# 107.-7-19 Pursuant to application dated 12/31/2020 and approved by the Building Inspector. To expire on 7/15/2022. Fees: SOLAR PANELS $50.00 CO-ALTERATION TO DWELLING $50.00 ELE TRIC $100.00 Total: $200.00 Building Inspector so Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® sean.devlin(rD-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To. Steven Orlowski Address: 1680 Westview Dr city:Mattituck st: NY zip: 11952 Building Permit#: 45677 Section: 107 Block 7 Lot- 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: GreenLogic License No: 43854ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment. 13.6kW Roof Mounted PV Solar Energy System w/ (34) 40OW Panels, PV Rapid Shutdown AC Disconnect Notes: Solar Inspector Signature: P Date: May 4, 2021 S.Devlin-Cert Electrical Compliance Form a0F SOUTy 7 7 06 Co) * } -TOWN OF SOUTHOLD BUILDING DEPT. courm a 765-1802 INSPECTION [. ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND -, [ ] INSULATIOWCAULKING [ '] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 457-d t NA-i-, ttek t)V. 'PZev-r1cV DATE 51q /Z-/ INSPECTOR --- OF SOUIyO� * TOWN OF SOUTHOLD BUILDING DEPT. co 765-1802 -- 'INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] SULATIO[qA/" N/CAULKING [ ] FRAMING /STRAPPING [ FINAL S [ ] FIREPLACE & CHIMNEY , = [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] LECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ CODE VIOLATION [ ] PRE C/O REMARKS: �VA &w\A s'('o(o(o u� tom4d 5�n te, C/ l h VI IV DATE l°I ?-o?/l INSPECTOR /V £ . \ - ƒ - t \a . 'FIELD INSPECTION REPORT DATE COIs � � k \ FOUNDATION (IST) 7 t / 2 ------------- k \S _ � y , FOUNDATION(2ND) M � 00 % K . 2 / • . \ �O y ROUGH SING& \ PLUMBING K . � \ � ' INSULATION PER N Y � S. STATE ENERGY CODE � • . \. � ~ � � r FINAL � � f. . . \ ADDITIONAL COMMENTS co ! \ AmeideA �� � � - � A �� . � ������ - �) k \ - m / � !, C � « _ m \ \ � / . . \ . . \ � \ - \ r= uF�ult��y TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 httys://www.southoldtowmy.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only D ' PER �b� 1 t Z/ Building Inspe or: =s DEC 3 2020 MIT NO. _ Applications and,f6rms must be filled'out in their entirety,.Incomplete -7 applications will not be accepted. Where the Applicant is not the'owner;an Owner's Authorizationzform(Page 2)shall be completed. Date: OWNER(S)OF PROPERTY: Name: Steven Orlowski SCTM_#___1_0_0 0 D7777—_ 1C� Physical Address: 1680 Westview Drive, Mattituck, NY 11952 Phone#: 631-334-6279 Email: SORLOWSK104@GMAIL.COM Mailing Address: 1680 Westview Drive, Mattituck, NY 11952 CONTACT PERSON:, Name:Steven Orlowski Mailing Address: 1680 Westview Drive, Mattituck, NY 11952 Phone#: 631-334-6279 Email: SORLOWSKI04@GMAIL.COM DESIGN PROFESSIONAL INFORMATION: Name: .- Mailing Address: 25 r®ar P VorrK K)y 000q Phone#: Email: `}� 'e �� conn 'CONTRACTOR'INFORMATION: Name:Premier Solar Solutions LLC Mailing Address: 23 Grand Ave, Farmingdale, NY 11735 Phone#: 631-482-8303 Email: operations@premiersolarny.com DESCRIPTION OF,PROPOSEUCONSTRUCTION' �,❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: I 90ther Roof mounted solar $34000.00 Will`tlie lot be re-graded? ❑Yes�No Will excess fill be removed from premises? ❑Yes 2No 1 lig 1 1 1 , s i 1 I , i PROPERTY INFORMATION �ting use of property: Residence Intended use of property: Residence Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes 2No IF YES, PROVIDE A COPY. 12 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to,the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section'210.45 of the New York State Penal Law. Application Submitted By(print name): ❑Authorized Agent ❑Owner Signature of Applicant: Date: STATE OF NEW YORK) p/SS: COUNTY OF jiJ/7i/,X-- ) SA1CJ t--,(\ being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)he is the CsrS�� CYjIC� (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief; and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 1021� , 20� Notary Public 'PROPERTY OWNER AUTHORIZATION (Where the applicant is not the owner) residing at 16k� <.J���Vlt�w �a (dot �+��� 8v`( WTI do hereby authorize Q're rnic- 5o61- Sc ukk n S to apply on my beh f tot e Town of,S ut old Building Department for approval as described herein. Owner's Signature Date LQualified LEEN M TAVEIRA r WMLIC,SPATE OF NEW YORK Print Owner's Name donNo.OITA6331188 in Suffolk County My on Expires October S, �oS�FFOCKco BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD a Town Hall Annex - 54375 Main Road - PO Box 1179 0 CIO - Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ' rogerr(c�southoldtownny.gov — sea ndccDsoutholdtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: Name: License No.: email: Address: Phone No.: JOB SITE INFORMATION (All Information Required) Name: tS: vaAorlejupski Address: 'e, VU 0' Cross Street: Phone No.: Bldg.Permit#: 1 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect - Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Fornn.xls PERMIT# Address: Switches Outlets G FI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments - -New Workers' __ �s1r°A_TE Compensation CERTIFICATE OF Board, NYS:WORKERS''COMPENSATION INSURANCE COVERAGE 1 a.Legal Name and address of Insured(use street address only) 1b.Business Telephone Numlier of Insured PREMIER SOLAR SOLUTIONS'LLC 631'=482=8303 1c.NYS Uriemploymerit-Insurance Employer 7H CONNOR LANE DEAR PARK,NY_ 11729 Registration Number of Insured 1d:Federal Employer Identification Number,of'lns_ured or �WorkLocation_of Insured(Onlyrequired fcoveragais,specifically Social Security'Number- -limited to certain locations iri New York.State,i.e.'a Wrap-Up Policy) 455065.418 .2. 'Name and Address of the Entity Requesting Proof of Coverage(Entity Being Listed as the Certificate Holder) 3a.Name--of Insurance Carrier NEW YORK MARINE 3b.Policy,Numberof Entity Listed'in Box"1a": Town of Southold 530954toute 25 WC201700615556 Po Box 1179 3c.Policy effective period:, Southold,NY 11971 10/19/2020 to 10/19/2021_ 3d.The-Proprietor,'Paitners-or,Executive Officers are Dlncluded.(Only,check box if alLpartners/officers included)' [3all excluded or certain partners/officers excluded. This certifies that the insurance.carrier indicated above in bok "3" insures the business referenced'aboye in bok "1 a" for workers'compensation under the New York State Workers' Compensation Law.'(To use_this form; New York(NY),must be listed under Item 3A on, the INFORMATION PAGE of the workers' compensation insurance policy).-The Insurance;Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder,in,-box"2" The insurance carrier -must notify the abov_e-certificate holder and'the Workers' Compensation Board Vvithin.10 days IF a policy is canceled due to nonpayment"of premiums or within 30 days IF there are feasbns other-than nonpayment of premiums that cancel'tfie policy 6r eliminate-the insured,;from the coverage indicated on,this Certificate. (These notices maybe sent'by regular mait.) Otherwise, this Certificate is valid for one year after this form is approiied by the insurance carne or its-licensed.agent, or until the policy expiration date listed in box"Sc's whichever is earlier. This-certificate is issued as a-matter,of information only and confers no rights upon-the certificate holder. This certificate 'does not amend,;extend or alter the coverage-afforded,by'the policy listetl,,nor-does ihconfer any-rights or.'responsibiliti_es beyond those contained-in-the referenced policy. This certificate may�_be used as evidence of-a Worker's Compensation contract of insurance only while the underlying_ 'Policy is-in effect: Please Note: Upon cancellation of the workers' compensation policy indicated on this form,If the business continues to be named on a permit,,license-or contract issued by a certificate holder, the business must provide ,that certificate holder with a new,Certificate of Workers' Compensation Coverage or-other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers' Compensation 'Law. Under Penalty-of perjury; I certify that I am an authorized representative or licensed agent of-the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by:, Jason'Schiciano (print name of authorized representative-or licensed-agent'of insurance carrier) Approved by: (Signature) (Date) Title: President Telephone.Number of authorized representative or licensed agent of insurance carrier: (914)457-4200 C-105.2(947) Form WC 88 3121 F Printed in U.S.A. www.wcb-.ny.gov Page 1 of 2 Suffolk County Dept.of € Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE j Name CHRISTOPHER E HOFFM N a< Business Name This certifies that the PREMIER SOLAR SOLUTIONS LLC bearer is duly licensed by the County of sutfolk License Number:H-59112 Fra"^wNa4'de" Issued: 09/07/2017 Commissioner Expires: 09/01/2021 PREMSOL-01 JBRUNO CERTIFICATE OF LIABILITY INSURANCE F (MMIDDNYYY) DATE 12/28/2020 12/28/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT AME: Levitt-Fuirst Associates,LTD PHONE FAX 520 White Plains Road (AIC,No,Ext):(914)457-4200 (AIC,N,):(914)457-4200 2nd Floor E-MAIL info@levittfuirst.com Tarrytown,NY 10591 ADDRESS: INSURERS AFFORDING COVERAGE NAIC# INSURER A:Southwest Marine Sr General Insurance Company 12294 INSURED INSURER B;New York Marine 8:General Insurance Co. 16608 Premier Solar Solutions LLC INSURER C:ShelterPoint 81434 7H Connor Lane INSURERD:Aspen American Insurance Co. 43460 Deer Park,NY 11729 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER M IDDNYYYI (MMII)DNYYYI LIMITS A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE F_v_1 OCCUR GL202000010338 10/19/2020 10/19/2021 DAMAGE TO RENTED 100,000 PREMISES(Ea oca r n $ MED EXP(Any oneperson) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $ 2,000,000 POLICY❑X JECT F] LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER A AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 _a_accidant $ ANY AUTO GL202000010338 10/19/2020 10/19/2021 BODILY INJURY Perperson) $ OWNED SCHEDULED BODILY INJURY Per accident $ AUTOS ONLY AUTOS X AUTOS ONLY X AUTOS ONL� Peoa dentDAMAGE $ A UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 3,000,000 X EXCESS LIAB CLAIMS-MADE EX202000001672 10/19/2020 10/19/2021 AGGREGATE $ 3,000,000 DED RETENTION$ $ B WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ANY PROPRIETORIPARTNER/EXECUTNE WC202000015556 10/19/2020 10/19/2021 1,000,000 �FFICER/MEMggER EXCLUDED? N/A EL.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ C Disability DBL515545 10/19/2020 10/18/2022 Statutory Limits D Inland Marine IMZ330719 11/17/2019 11/17/2020 Install.8r Material 500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached if more space is required) Town of Southold- is included as Additional Insured for covered operations of the named insured, CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town Town Route h ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 1179 Southold,NY 11971 AUTHORIZED REPRESENTATIVE I � X.A 49 ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD EfYORK workers' CERTIFICATE OF INSURANCE COVERAGE sTAA Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured PREMIER SOLAR SOLUTIONS LLC 7H CONNOR LANE 3475450159 DEER PARK, NY 11729 Work Location of Insured(Only required if coverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-Up Policy) or Social Security Number 45-5065418 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York Town of Southold Y P Y 53095 Route 25 3b.Policy Number of Entity Listed in Box"l a" PO Box 1179 L90441-000 Southold, NY 11971 3c Policy effective period 8/1/2020 to 12/27/2021 4. Policy provides the following benefits: Q A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. ❑ C.Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. ❑ B Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as des d above. Date Signed 12/28/2020 By - 9-cpjait (Signature of insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 46,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board(only if sox 4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) �IIIIIPiiiiiu1ii2ii0mi1iiiiii1ii0iiii1ii7iiii�lllll Tom Petersen Architects Planners Construction Official December 8,2020 Building Department for project at: 1680 Westview Drive Mattituck,NY 11952 Re: Solar Panel Installation Orlowski Residence 1680 Westview Drive Mattituck,NY 11952 Dear Sirs, I've reviewed the proposed solar panel installation at this location to evaluate the existing roof structure and the connection of the panels to the roof. Criteria: Applicable codes: 2020 Residential Code of New York State(pub.date:Nov.,2019) 2018 Wood Frame Construction Manual Design roof load: 30 psf live load, 10 psf dead load,40 psf total load Design wind load: 130 mph,35 psf;Exposure Category`B' My findings are as follows. 1. The new solar panels will imply an additional dead load of 3 psf. The existing roof structure (2x6 roof rafters @ 16"o.c.,with 2x8 ridge,span=+/- 12'-10"at maximum)is sufficient to bear this additional load. Any assumed, inaccessible or concealed structural members not documented during the initial site analysis will be verified by the solar panel system installers prior to the system installation,and any discrepancies will be reported to the Architect in writing. 2. The solar panels are attached to the roof with the solar rack system by Unirac,with components as shown on the attached drawings. The rack system,roof connections and connection spacing are rated for 130 mph. Flange footing connections to the rail are not required to be staggered. The flange foot connections to the roof are 5/16"diameter x 5"long lag bolts. The total panel installation is no higher than 6"above the existing roof plane. I therefore certify that this installation complies with the applicable codes and design loads mentioned above and is acceptable for approval. Please let me know if you have any questions on this information. Thanks! ED A&C *Sireilyyours, o�P,S F. PIz- �k Tom Petersen (P 03529� Q� Cc: Michael Tarzian,PhRGD G 3 NO y 6 Country Lane•Howell,New Jersey 07731•Telephone 732-730-1763,Fax 732-730-1783 Drafting/Design Film SYSTEM LAYOUT PhRGD Scale. ("=8'-0" _ 25 Broadway 9th Floor A _Z F`:' ,E�;— — :'` .��xT- - -� � �. �a _�� ' NY,NY 10004 ` «"< awl - `z = `., - (833 747-3639' Developer LEGEND Tx, .-' x t r "'' \aa` ""�< °�-k..a 'y , -;." `xa. - % H -<�d auz -'i•"s ,�4: a�, �rx �"�� ,' - ' 'a'a a,!°, ,£H'e \k"<"a- ,, .`,y"," '^'k _ «�.•- n.. S°>%�`,` '�'`: , s«, , , ."sa �> FD SetLails&1'atln,nta c - y� a, $, '� ,�' =fie .y�g> 's.� _ a�\\`:�°�0 1 (f1 - ��„'Fw•,� / `�\\" °f3=- ye'' � �'"` �, 3�`Y « - _�,,: """ate\,` L\ \_a tP" ' �' �``a / �• •� s ` 4-�"'�.� `�-:�`„s,,.-•,«`* `� _,����`” a.� x %'a�, �' - " ',' is �¢ `` �>Q, .� \ "-a �' y= „��" -- a A,C Home Rw, ','Wz .r` :�> - - — ,/dl'r. �"�> :,S e„�'ta- .Q \ �< � '�ul:r'tllrcL� soturlor(s «t� , x✓ 7' �-��.'_. "a zr� ,d�' - w, �',� �, '�'''� -'�ay' �" ��{�„tz� 'FR a, ,�,, �, 'g s - z 4 Y 1 a sz, e e .x d �r �z3 Premier lar tion 7 Connor Ln H, Heavy Sbadc a,,s, �..,'� ,/.,'` §1 ,/v,'``.��/;,`_a J. %• ” ; \4 _ 4. .it✓;v �ai,,it .&. .F`, " ,,,z, > a,73,,a, l - _<ry. ' ,.'a « 2 „ 2$ Certain' eed �e, ;: '," / � '«," a�, ,a.- "a Deer Park,NY 11729 ohw.nmtvrnre,Fet '" ,_ ' 631 482-8303 y'. >, ,' s 400W Solar Panels ' o��p :y:, `:% 1"4, a. i" _ ,.,. ^ ,Ty�a�"., d d a'" *_.,_ -���-'�t�<, s�`�`�4 '�` °✓ �"/x.'" � � �a � .. -- - - - j , r �'/a« - ,4 § Solu Inverrer/Eleelnul Egmpmrn ' - ` a; s, „\ PROPERTY INFORMATION ,fs 8` 9st y: �e Tax Ma 1000107000700019000 ~ ^ p: \` ' R .'^ 'g" �ter: ,? i <'<"�\x` x`= '�'` -,ice Q lumnev `°'6" h C " y� 2 - � Roof 1 Azimuth: 39 � ;Z <� = -/ -Azimuth: �:� �,,�y #- 3 ,•ti's`w �\\, 7 % r%d / r� � S _ wf >W y / n i ° r / / L h5 �«s �x Roof 2 Azimuth:59 ' 1� OR 'Ut �­',�d,a Panel Tilt 18° vs. „Z3` 3 � a x"� �1\ V �°„Sol �” � �� e, � x y �, d Roof of 1" 'a 3 "a" .�\�`a r b� �`� �: �-a,i1. dt a x\ .:v .- <<n oa, ',-rz°'' uz " °n• < y; rte' ^- " :- `y iA- ';t e >:a, `.. \ r R ofm° Material Composite Shin. + �,/".,,. "' �,<. <l: .,.' _i; �'" bis a °� �:' %.\ ''•`�€,i,dny, -�' " ` y f>« `fir,:-`�•rd„ `sY xR" w>s">� �> =',��,'' '`.:3 •�°' ''.�, a.:. .°«</,,• .� " // >-k,,� ts. 't n`"✓/ � �,r l.,« aC` a .c� " ..ter,'-, ", '�" s h' ja �� Y e„ ^i" r„ :rx` v„Ei� �” ?`4 d x�\ •e/ "C, "�% ;«,«" 9�.�'�" , >_;<', �.�.',o">" �\ s ° '� '.^` .' :' r3a' ±� d- 04 y` fr / �.. PE Stamps/Signatures °�°Z g„� d<' ,.a xr - "'rr� ^,t > .¢-a." :��e, f,`!':�,"r„ems e _ �rtx �a'f. 'Qi��. x�q �, �; ;�� • � •'�" �~ �° ' Thomas Petersen s' s� a� maw, '6 "� � ,?y,an'� �- �"" .� � �__ f' Al '\ za /" _ Tom Petersen Architect,LLC 6� �' *?'fir- �"-i,' sed(„�.�,'" ' :�, � - � � �` a':.s .` _:,` ";3`r ^urn Int ` P""" y �E, s"=' ;iia"; - z� �;°`" , o ",, h4 r 6 Count Lane � �, ._ ,. _e ate_ i _ ,, uc�` �;- Howell NJ 07731 �: „i° � as `--� ,��/'«'r ;.�\. NY Architect License#035290 �';$, " « :.' s, IN. - �� - Nc ,�E,,�, 3a. a�>" "lS ''S'�fl ,E-� :c�'"`3'�` ,r" % L`Ol - <; "f r, ,r, /¢ _ ,.<-4 >" ::%>`. Vii/ a -'` 'r 's' `.:''<.,vr,� n,= SIXvi �- 'z» i .a ro+7` ff x`3 �, ��., 1.d b`�` "3a� < ,=�✓'" Vol _ °s: ✓,� a` '3` '� �^ a»:« `" is s., w�,..,,a*,r eCMI =1 '« .� -`£v X.f^' '7'<y 'aY " 'moo�.'✓r"., a s,< Description s, '� D �: Rev DateInitial r r �`�_ r� " Desl n `=`�"� ��", 00 (2/2/20 MJ S/., y,x > ,�, \ � rzh ; � <� ��� ;.;>< O1 (2/11/20 Panel Change MJ r a: e g '« _ Panel Chan e r � ' y�r' � r�, 02 12/14/20 g MJ ham, °fir s a <� �; .�; 03 04/29/21 Buil M � °i As t J 41 3,'',. \ =6 "'' �\ .1" "e, .fr " r mercy" ' _ ` '.F z+z, a >`„`�z` `a r w c.'"= 1680 Westview Drve, OR ° " ys rr ,ewa, ;;, ,.,s<. a, :- ori E- ` ; � " ° , . s M ;a `, 'g .,utp't r " - Mattituck NY 11952 ® ` ' '.,d� .C''„''iu �i' <•,, HS'\,'m�` �,� � Otvner Orlowski Residence Solar Modules 34 400W Modules F"Ir 5�`JR %i I v 1 4 0 In 4 ,� a Solar Inverters SE l l 0 H-US v 2029 \� `� • ` =�==: .,�` , „�":, '��r> " a<" TMWl m D z 13 6kW 'A ,, "`;�� "�" ,\ � � � :✓ `t" So az System CSI e- Solar System AC Size l 14 kW �PTr :` ,. _ �` ,` v'i ,• _ ;`.`� " Page Slze 11"x l7" Rpy�1,Rp�e.YD3teTt;I) r" 'S� �D T �I® � SYSTEM LAYOUT 0., �. ;,t ',a a Scale See Scales Page_of 8 �. �, °� `ft SCALE 1"=T-0" IN FEET ( 1 Talc_aI`and Instat anDin �,a. a- .��.,«; `S has ` ,. Q r M i0 rrGeneral-Nous" \`y= T � 5 A 000.03 0 "' fir, :.,, ,a�,`aa\ 1-LINE DIAGRAM end Drafting/Design Firm CertauiTeed Mono Panel Meter To ASHRAE High Lot;Temps Bwldmg CT400HC91-04 PhRGD , Maximum Power 400W+0-5W NY,NY High Open-Circum Voltage 48 6V NY,NY Low=14'C Short-Circuit Current 10 6A Voc Tem Coefficient -0 31%/C° 25 Broadway 9th Floor I p NY,NY 10004 Vpmax 40 8V Voc Low Tem VocLow 48 6V- -0 149V/C ° °--14C =54 0V 1 I Ipmax 9 8A p( )= tr , [25C ( )]} (833)747-3639 89L A/C SolatEdge Disconnect I Vmp High Temp=40 8V-{-0 I49V [25C°-(33C°)]}=39 2V PV Array I SE114000H-US MAIN DISCONNECT I Developer °u, I SolarEdae Inverter SE1140OH-US ;r Max Pdc 17650 W 1 Max Vin 480 V Max Isc in 45A SolarEdge Optimizer A/C Disconnect Switch TO Max Pac 11400 W P400 SQUARE D 60A Rated JEL EXTERNAL I Max Iout Continuous 47 5A Max Vin 80V 60A Fused Disconnect PwlE LAR-soLUTIONS CIRCUIT I GFDI Threshold 1 Max Isc 10 IA 140/120V 3 Wire ` Max Vout 60V UL Listed Approved Premier Solar Solutions SIDE OF Max Iout 15A Knife Switch 7 Connor Ln H, ROOFTOP GARAGE I BUILDING Deer Palk,NY 11729 (631)482-8303 3-LINE DIAGRAM PROPERTY INFORMATION Tax Map 1000107000700019000 Key I I Roof I Azimuth:239° Roof 2 Azimuth.59° Positive ROOF I GARAGE GARAGE I SIDE OF BUILDING Panel Tilt: 18° Negative I I Ground — (1)L1 46 CU Conductors THWN-2(Minimum)(or Equivalent) 1 L 1 L2 (1)L2#6 CU Conductors THWN-2(Minimum)(or Equivalent) PE Stamps/Signatures ' I (1)Neutral#6 CU Conductors THWN-2(Minimum)(or Equivalent) 1 Neutral I (1)Grounding#8 CU Conductors THWN-2(Minimum)(or Equivalent) I Thomas Petersen 1 3/4"EMT Conduit(Minimum)(or Equivalent) I Tom Petersen Architect,LLC 16 Country Lane \hty Grid Howell NJ 07731 NY Architect License#035290 3 Strings (34)Certain Teed 40OW Panels I I (34)P400 Optimizers I I SolarEdge Point of Interconnection I SE1140OH-US IPC Connectors 250 VAC rated UL Listed String 1 MPII 89L 60A A/C I 10 Mods orc arc Disconnect ---------- Load Side Bt-Directional Utility Meter 10 Optimizers D/C I m R I i I 200A 240V I Single Phase �W 00 Cutler-Hammer 120V 3 Wire w _[ - I Kmfe I I Switch Main I Meter#098296789 Disconnect Rev Date Description Initial String 2 ID/C A/C I 60A 8 1 00 12/2/20 Design MI To External MPI _ 1 1 01 12/11/20 Panel Change M! 12 Mods 02 12/14/20 Panel Change MJ 12 Optimizers I ! Circuit I 03 04/29/21 As Built MJ 1680 Westview Drive, String 3 I - - - I Mattituck,NY 11952 MPI j 1 (3)Positive#10 Conductors PV Wire 13 Modsm - PV WI Owner Orlowski Residence L 12 Optimizers _(3)Negative#10 Conductors ire Solar Modules (34)400W Modules I (1)Grounding#10 Conductors PV Wire 1)Grounding#6 I 3/4"EMT Conduit • Conductor 1 Solar Inverters (1)SE 1140OH-US Inv 1 Existing Budding Ground I Solar System DC Size 13 6kW elf Bonding Panel and Rail Solar System AC Size 114 kW 1 (1)L l#6 CU Conductors TH -2(Minimum)(or Equivalent) Page Size I V x 17" I (1)L2#6 CU Conductors THWN-2(Minimum)(or Equivalent) I ELECTRICAL 3-LINE& F 1 (1)Neutral#6 CU Conductors THWN-2(Minimum)(or Equivalent) (l)Grounding#8 CU Conductors THWN-2(Minimum)(or Equivalent) I-LINE 1 3/4"EMT Conduit(Minimum)(or Equivalent) I Scale See Scales Page 4 of g E-000.03 Drafting/Design Firm CONTRACTOR NOTES EQUIPMENT NOTES ABBREVIATIONS PhRGD I THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE SYSTEM DESIGN I ALL MATERIALS SUPPLIES AND EQUIPMENT SHALL BE LISTED USED AND INST ALLED IN ACCORDANCE WITH THE MANUFACTURER'S A AMPERES 25 Broadway 9th Floor ENGINEEROF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS RECOMMENDATIONS AND INSTRUCTIONS AND APPLICABLE NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL)REQUIREMENTS AC ALTERNATING CURRENT NY,NY 10004 -- 2 THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL WORK AS SHOWN IN THE CONSTRUCTION 2 ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED AF AMP FRAME 833 747-3639 DOCUMENTS UNLESS OTHERWISE NOTED ALL WORK SHALL BE PERFORMED IN AN ORDERLY, AFDI ARC FAULT DETECTION INTERRUPTER WORKMANLIKE AND SAFE MANNER BY WORKERS SKILLED AND EXPERIENCED IN THEIR TRADES 3 WORKING SPACE AROUND ELECTRIAL EQUPMENT SHALL COMPLY WITH NEC 11026 AT AMP TRIP - ATS AUTOMATIC TRANSFER SWITCH er Develo ALL REQUIRED AND NECESSARY PERMITS SHALL BE SECURED FROM ALL MUNICIPAL AGENCIES HAVING 4 THE APPROXIMATE LOCATIONS OF ALL JUNCTION BOXES COMBINER BOXES CONDUITS ETC SHALL BE DETERMINED FROM THE AWG AMERICAN WIRE GAUGE P JURISDICTION AT THE COST AND EXPENSE OF THE CONTRACTORS PRIOR TO THE START OF WORK DRAWINGS,AND VERIFIED BY THE CONTRACTOR FOR INSTALLATION BIL BASIC IMPULSE LEVEL ALL JUNCTION BOXES,COMBINER BOXES AND DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION BIB BYPASS ISOLATION BREAKER 4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL INSPECTIONS TO BE WITNESSED BY - BPS BOLT PRESSURE SWITCH THE AHJ AND/OR THE OWNER THE CONTRACTOR SHALL WORK WITH THE OWNER'S INSPECTION AGENCY CA CIRCULAR MILS AREA 6 PROVIDE NEMA 3R RATED EQUIPMENT OR BETTER WHERE EXPOSED TO OUTDOORS CB COMBINER BOX TO PLAN THE INSPECTIONS AND NOTIFY ALL PARTIES INVOLVED SUFFICIENTLY IN ADVANCE TO ALLOW µ THE INSPECTIONS TO TAKE PLACE IN A TIMELY MANNER AND NOT DELAY THE PROGRESS OF THE WORK 7 WHERE SIZES OF RACEWAYS OR BOXES ARE NOT INDICATED ON THE DRAWINGS THE CONTRACTOR SHALL SIZE THESE ITEMS AS COMM COMMUNICATIONS THE OWNER AND SYSTEM DESIGN ENGINEER WILL NOT BE RESPONSIBLE FOR SCHEDULING,ARRANGING REQUIRED FOR THE INSTALLATION CT CURRENT TRANSFORMER OR COORDINATING THE INSPECTIONS CP CONTROL PANELy i ¢ i CONTRACTOR SHALL FURNISH ALL NECESSARY BOXES OUTLETS SUPPORTS CONDUITS FITTINGS AND 8 ALL VERTICAL RUNS OF CONDUIT OR TUBING TERMINATING IN THE BOTTOM OF WALL BOXES OR CABINETS OR SIMILAR LOCATIONS. CPT CONTROL POWER TRANSFORMER �R1=P°�IERSO ri SOLUPONS SHALL BE PROTECTED FROM THE ENTRANCE OF FOREIGN MATERIAL PRIOR TO THE INSTALLATION OF CONDUCTORS ACCESSORIES TO FULFILL APPLICABLE CODES,REGULATIONS,BUILDING STANDARDS,AND THE BEST CU COPPER Premier Solar Solutions PRACTICE OF THE TRADE FOR THE INSTALLATION OF ELECTRICAL WORK 9 METAL RACEWAYS,METAL ENCLOSURES OF ELECTRICAL DEVICES AND EQUIPMENT,MODULE FRAMES,AND OTHER EQUIPMENT SHALL CO CONTINUOUS OPERATION CURRENT BE COMPLETELY GROUNDED IN ACCORDANCE WITH THE NEC PROPER HARDWARE FOR A COMPLETE GROUNDING AND BONDING CYC CYCLE 7 Connor Ln H, 6 THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS WHOSE WORK MIGHT SYSTEM SHALL BE INSTALLED BY THE CONTRACTOR,IF NECESSARY D DISTANCE Deer Park,NY 11729 AFFECT THIS INSTALLATION CONTRACTORS SHALL ARRANGE ALL PARTS OF THIS WORK AND EQUIPMENTDC DIRECT CURRENT (63 1)4 IN PROPER RELATION TO THE WORK AND EQUIPMENT OF OTHERS AND WITH BUILDING CONSTRUCTION 10 GROUNDING RODS SHALL HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS AND SHALL BE 5/8 ,8'MIN COPPER-BONDED STEEL DISC DISCONNECT 82-8303 AND ARCHITECTURAL FINISH SO THAT IT WILL HARMONIZE IN SERVICE AND APPEARANCE ALL GROUND CLAMPS USED SHALL BE UL 467 LISTED EDP EMERGENCY DISTRIBUTION TRANSFORMER EGC EQUIPMENT GROUNDING CONDUCTOR I I ALL PVC CONDUIT EXPOSED TO SUNLIGHT SHALL BE SCHEDULE 80 AND MARKED AS SUNLIGHT RESISTANT ALL UNDERGROUND PVC EHDP EMERGENCY HIGH VOLTAGE DISTRIBUTION CONDUIT SHALL BE SCHEDULE 40 OR 80 PANELBOARD PROPERTY INFORMATION TENANT SAFETY NOTES ELDP EMERGENCY LOW VOLTAGE DISTRIBUTION PANELBOARD Tax Map 1000107000700019000 EMT ELECTRICAL METALLIC TUBING I THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THE AREAS WHERE WORK IS TAKING PLACE AS WELL EPR ETHYLENE PROPYLENE RUBBER AS ANY ADJOINING AREAS WHICH MAY BE AFFECTED BY THE WORK,TO PREVENT SUBJECTING THE OCCUPANTS, EQUIP EQUIPMENT Roof 1 Azimuth:239' STRUCTURES,VEHICLES,EQUIPMENT,OR ANY OTHER PARTS'OR CONTENTS OF THE SITE TO HAZARD OR DAMAGE ELECTRICAL NOTES EXIST EXISTING GND GROUND Roof 2 Azimuth:59° 2 CONSTRUCTION SHALL BE PERMITTED DURING NORMAL BUSINESS HOURS 8AM TO 5PM AND SHALL NOT EXCEED GFCI GROUND FAULT CIRCUIT INTERRUPTER , PAST THESE TIMES I ELECTRICAL POWER MUST BE SHUT OFF PRIOR TO THE CONTRACTOR PERFORMING ANY WORK IN RACEWAYS WITH LIVE ELECTRICAL GFD GROUND FAULT DEVICE Panel Tilt 18° CIRCUITS OR ANY OTHER EQUIPMENT WHEN SWITCHES OR CIRCUIT BREAKERS ARE OPENED FOR WORK ON ELECTRICAL EQUIPMENT OR HWG HEATER WATER GAS LINE WIRING,SIGNS OR TAGS SHOULD BE INSTALLED AT THE SWITCH OR BREAKER STATING THAT WORK IS BEING PERFORMED ON THEM INV INVERTER 3 THE CONTRACTOR SHALL,AT ALL TIMES DURING THE WORK,MAINTAIN ACCESSIBILITY FROM THE STREET TO ALL INCLUDE THE TIME,DATE,AND CONTRACTOR'S NAME ON THE SIGN OR TAG IF DEVICE IS LOCKABLE,IT SHOULD BE PADLOCKED Ipmax NOMINAL CURRENT(AMPS) FIRE HYDRANTS POWER OR LIGHT POLES,AND SIMILAR UTILITY AND PUBLIC SERVICE ITEMS WITHIN OR ADJACENT IMC INTERMEDIATE METAL CONDUIT 2 THE ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE AHJ,NATIONAL FIRE PROTECTION AGENCY(NEPA),NATIONAL TO THE CONSTRUCTION SITE KCMR. THOUSAND CIRCULAR MBS ELECTRICAL CODE(NEC),AND OSHA 4 WORK SHALL NOT RESTRICT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUITION KV THOUSAND VOLT FACILITIES(POWER POLES,PULLBOXES,TRANSFORMERS VAULTS,PUMPS,VALVES,METERS,APPURTENANCES, 3 PHASING OF NEW CONDUCTORS TO MATCH EXISTING CONDUCTORS IF INSTALLATING A NEW CIRCUIT,THEN CONTRACTOR SHALL KVA THOUSAND VOLT-AMP PE Stamps/Signatures ETC)OR TO THE LOCATION OF THE HOOKUP FOLLOW THE PHASING SCHEMES PROVIDED IN THE ELECTRICAL DIAGRAM KW THOUSAND WATT LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT Thomas Petersen i THE OWNERS AND THE AHJ SHALL BE NOTIFIED IN WRITING IN ADVANCE OF ANY REQUIRED CONSTRUCTION 4 ALL CONDUCTORS SHALL BE COPPER,RATED FOR 90°C WET ENVIRONMENT,AND 1000 VOLTS DC OR 600 VOLTS AC UNLESS OTHERWISE LSC SHORT CIRCUIT CURRENT Tom Petersen Architect,LLC OPERATION THAT WILL INVOLVE INTERRUPTION OF THE HEATING,WATER,FIRE PROTECTION SYSTEMS, NOTED LSIG LONG,SHORT,INSTANTANEOUS,GROUND TELEPHONE,GAS OR ELECTRICAL SERVICES TO THE OTHER BUILDINGS AND AREAS OF THE SITE THE CONTRACTOR TIME 6 Country Lane _ SHALL COORDINATE ANY REQUIRED SHUTDOWN OF THE UTILITIES WITH THE OWNERS,THE AHJ AND THE UTILITY 5 EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A MAU MAKEUP AIR UNIT - COMPANY RACEWAY OR CABLE ARMOR MBP MAINTENANCE BYPASS BREAKER Howell NJ 07731 6 ANY DAMAGE TO SURROUNDING PROPERTIES INCLUDING SIDEWALKS,CURBS,TREES AND STREET SHALL BE 6 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250 MCB MINI CIRCUIT BREAKERS NY Architect License#035290 MCCB MOLDED CASE CIRCUIT BREAKERS REPAIRED SATISFACTORILY TO ORIGINAL CONDITIONS 7 GROUNDING ELECTRODE CONDUCTOR(G E C)SHALL BE CONTINUOUS AND/OR IRREVERSIBLY SPLICEDIWELDED MIB MAINTENANCE ISOLATION BREAKER 7 PERSONAL PROTECTIVE EQUIPMENT(PE)SHALL BE PROVIDED AS REQUIRED IN ACCORDANCE WITH NEC 70E AND MISC MISCELLANEOUS OSHA REQUIREMENTS 8 FLEXIBLE,FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS,LUGS,DEVICES,OR CONNECTORS THAT ARE MFG MANUFACTURER IDENTIFIED AND LISTED FOR SUCH USE PER NEC 690 31(F) MDPT MAXIMUM POWER POINT TRACKING 9 THE UTILITY INTERACTIVE INVERTER SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION NMEDIUM VOLTAGE NE AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THE STATE UNTIL THE ELECTRICAL EC NATIONAL ELECTRIC CODE PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION GENERAL NOTES 10 DUE TO THE FACTS THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT,PV CONTRACTOR SHALL DISABLE THE ARRAY NESC NATIONAL ELECTRIC SAFETY CODE I THE GENERAL NOTES APPLY TO ALL DRAWINGS UNDER THE CONTRACT REFER TO INDIVIDUAL DRAWINGS FOR ADDITIONAL DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING OPEN CIRCUITING,OR COVERING THE ARRAY WITH OPAQUE COVERING NTS NOT TO SCALE OCPD OVERCURRENT PROTECTION DEVICE NOTES I I ALL WIRES SHALL BE IDENTIFIED BY CIRCUITS IN ALL CABINETS BOXES,WIRING TROUGHS AND OTHER ENCLOSURES,AND AT ALL PCC POINT OF COMMON COUPLING 2 UNFORESEEN OBSTRUCTIONS ON THE ROOF MAY REQUIRE A CHANGE IN THE LAYOUT ANY CHANGES TO THE RACKING TERMINAL POINTS,I E,RECEPTACLES,MECHANICAL LUGS,COMPRESSION FITTINGS THE CIRCUIT DESIGNATIONS SHALL BE AS SHOWN PDU POWER DISTRIBUTION UNIT LAYOUT SHOULD BE REPORTED TO THE ENGINEER CHANGES IN UP To 6%OF THE MODULES SHOULD BE ANTICIPATED ON THE CONTRACT DRAWINGS OR AS DIRECTED BY THE SYSTEM DESIGN ENGINEER LABELS OR TAGS SHALL BE APPLIED TO WIRES SO PF POWER FACTOR CHANGES TO THE ARRAY LAYOUT SHOULD BE MADE AS TO NOT IMPACT THE NUMBER OF MODULES ON A COMBINER BOX OR THAT THEY WILL BE READILY VISIBLE POI POINT OF INTERCONNECTION INVERTER 12 BREAKERS SHALL BE 80%RATED UNLESS OTHERWISE SPECIFIED PRI PRIMARY PT POTENTIAL(VOLTAGE)TRANSFORMER. Rev Dale Description Initial DRAWINGS ARE DIAGRAMS AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK FOLLOW DRAWINGS IN LAYING 13 FUSES FOR SWITCHES SHALL BE CURRENT-LIMITING TYPE WITH A MINIMUM INTERRUPTING CAPACITY OF 200,000 AMPERES RMS(UNLESS PV PHOTOVOLTAIC OUT OF WORK AND CHECK DRAWINGS OF OTHER TRADES TO VERIFY SPACE CONDITIONS OTHERWISE NOTED)AND OF THE CONTINUOUS CURRENT RATINGS AS INDICATED ON THE DRAWINGS OR AS RECOMMENDED BY THE PVC POLYVINYL CHLORIDE 00 12/2/20 Design MJ MANUFACTURER PWR POWER 01 12/11/20 Panel Change MJ RCA RECYCLED CONCRETE AGGREGATE 02 12/14/20 Panel Change MJ PHOTOVOLTAIC NOTES RIB UPS RIGIDMTI03 04/29/21 As Built MJ RMC RIGID METALAL CONDUIT RS RAPID SHUTDOWN RTU ROOFTOP AIR HANDLING UNIT 1 ALL ASPECTS OF WORK RELATED TO THE SOLAR PHOTOVOLTAIC(PV)SYSTEM SHALL BE IN ACCORDANCE WITH ALL STATE AND LOCAL TESTING SA SURGE ARRESTER CODES,UTILITY REQUIREMENTS,AND THE NEC,ESPECIALLY ARTICLE 690 SCH SCHEDULE 1680 Westview Drive, SEC SECONDARY Mattituck NY 11952 2 SOLAR PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER E G C PER THE MODULE MANUFACTURER'S LISTED I FINAL TEST AND INSPECTION SHALL BE HELD IN THE PRESENCE OF OWNER'S REPRESENTATIVES AND TO THEIR SATISFACTION SPD SURGE PROTECTION DEVICE i INSTRUCTION SHEET TBD TO BE DETERMINED Owner Orlowski Residence 2 MEGGER ALL STRING WIRING,COMBINER BOX OUTPUT FEEDERS,AND AC FEEDERS SUBMIT RESULTS TO OWNER FOR REVIEW UL UNDERWRITER's LAB 3 SOLAR PV SYSTEMS SHALL BE GROUNDED IN ACCORDANCE WITH NEC 690 PART V GROUNDING Solar Modules (34)400W Modules o IV CURVE TRACES OF STRINGS SHALL BE GENERATED USING THE SOLMETRIC PV ANALYZER(OR EQUIVALENT DEVICE)AND UPS UNINTERRUPTED POWER SUPPLY 4 COMBINERBOXES FUSING,WIRE SIZES.QUANTITIES AND CONDUIT SIZES BETWEEN SOLAR ARRAYS AND INVERTERS TO BE VERIFIED BY SUBMITTED TO OWNER FOR APPROVAL V VOLT CONTRACTOR WITH SOLAR MODULE AND INVERTER MANUFACTURERS BEFORE INSTALLATION VA VOLT-AMPERE Solar Inverters (l)SE 11400H-US Inv Vui INPUT VOLTAGE Solar System DC Size 13 6kW i ALL PV SOURCE CIRCUIT CONDUCTORS AND CONNECTORS SHALL BE SUPPORTED AND SECURED WITHOUT EXCESSIVE STRESS NO WIRING VOC OPEN CIRCUIT VOLTAGE SHALL BE PERMITTED TO TOUCH THE ROOF SURFACE VOC Low MAXIMUM OPEN CIRCUIT VOLTAGE IN Solar System AC Size 1 l 4 kW 6 PV SOURCE CIRCUIT CONDUCTORS EXPOSED BETWEEN ARRAYS SHALL BE SECURED ON BOTH SIDES,AND BE PROTECTED FROM PHYSICAL LOWEST TEMPERATURE CONDITIONS Page Size l 1"x 17" DAMAGE AND ABRASION,INCLUDING FROM EDGES OF RACKING,CHANNEL EDGES WIRE TRAYS.ETC W WATT OUTPUT VOLTAGE GENERAL NOTES�+ 7 ANY CABLE TIES USED SHALL BE HE AT STABILIZED(-A1C TO 105C)UV STABILIZED AND OUTDOOR RATED,SUITABLE AND DURABLE FOR WP WEATHER PROOF GE1V J_RAL 1 V O 1 EJ THE ENVIRONMENT AND LIFE OF THE PV SYSTEM XFMR TRANSFORMER -- 8 WHERE EXPOSED TO SUNLIGHT,CONDUCTORS SHALL BE LISTED AND MARKED AS SUNLIGHT RESISTANT z IMPEDANCE Scale See Scales Page 6 of 8 9 ALL EQUIPMENT GROUND CONDUCTORS SMALLER THAN AWG 46 SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY AN IDENTIFIED O O O.0/'� J{ RACEWAY OR CABLE ARMOR UNLESS INSTALLED WITHIN THE HOLLOW SPACES OF THE FRAMING MEMBERS OF BUILDINGS OR STRUCTURES _ AND WHERE NOT SUBJECT TO PHYSICAL DAMAGE Drafting/Design Firm Electrical Characteristics s9ow 59sw 400w 3 'e ' ry Y t � Iiamina104tPUt(P+nPP), 1::�-M� ..]90'` ,� ""''�, m - t Vol[a9eatPTJx(VmPP7 V 404 4o6 4oe Power:-Optimizer , ,,� _ ��,2 " i> �9a"_ PhRGD For North`America' ✓ open Lo-curt voltage(vgcl v 4ez 4s4 'Ni. " ^' 25 Broadway 9th Roof P320/P340/P370P400/P405/P505- NY,NY 10004 " 3a ^;S'Y & °-s"T- �'y Outnu[Tol¢rJnCe Vv _ -_ .pr.5 A _ ,< ^ " s . _ v k 44 ,. ._. :,_,_ _ (833)747-3639 otcsuit peo_Nanz < _ f ' 7,; -`u4'n,`x(e-4nustasawrtas(�ppasswoaas 5erle2 F.I.Raun9y - -- ----- -' 20A < • '�'> J Q ° Developer ,.�� � �.J r '°.z=�'��'t �a]d'i. �c¢IITyr,e-� ... _-.��,�;a.�,:,<: m����s,.w»� erhaH•wt�nomsralrg �'e'=&..`- �<a��. {j7�" - - " - - j^-a�y� Mla Elh<e cYn % t94 - .. ��w�■ 196 199 - ,\I' otlu - mpan.a:ecfjagmat rift Bii �TemP'--rat o CPefflnent of Voc %/C •--- - - -"- - •O 31 -- -' �3 r < ,d 1'� D ®�- " ITemxenurctfry ��w..a�,;•"'�,p�, ^�,°:��' �,`o u5° vSx°"'�'r�v''rx�r'M1�.Sh' .a Y ..< ° ., <� Lin AEL Mechanical Characteristics �J Dimensions y' ` , pRMi>: CLAsotuTIos ' Lamina. rn PrOnllel'SOel l ° - `,ntgs "te"`p'arer-3.anita¢rtectw» ,y`� r, _ , - m �;'•r '/Tr'1 Solutions l�lfl Half-Cell Monocrystai6ne Type Seereve•s'=f„r > `°° la"r vA p " ,`�< ,'„''"` 7 Connor Ln H, rnuL.sUcctP+caGooz `;�a;'•�a agwoaaa aatt,�" ' - } ;i ✓ Deer Park,NY 11729 LT39ORC11-04 5" ', 'cF �t�kfEtitill',�1'h�Ca}s _ -- i %,r«y�'b` � �'fc� >, (631)482-8303 [7390X[00 04 Fmma anotlaea aluminum(slack or snveq '" "'F C1395HCII 04 1 Power Output [7395X[00.04 mnfh CT400NCII-04 Warranty Output 4 LaD1<;$ nsim(12AWG)PV wire, PROPERTY INFORMATION .” Ci400NC00 04 I 2m(4 PV power-optimization at the module-level a_ Features and Benefits #" Weight 23Okg(507102) T 1' =i Tax Map: 1000107000700019000 High OualhV/High Power .x. .Y J Speo6ca11ye-gned toworkw,th Sol-'Edge f Fast insfallahon with a single bolt 7{ �,�'a^���Operating conditions I I °¢rter3 Roof I Azimuth:239° a Up tp 39Uw Dlact De<k,FeM{4001•lMMeback.neet ,jam $ '> P 9 --" 1n /Next generation mdtntenano,Wlthmodule- _l� I Up to 25%more energy levelmonitonng s UL lstetl NLl]03) ^ • a ” NpirtlrW`[Qp¢rzib�it9 ,9,fim ` 'a Superior efficiency(99 5%) 7 Meets NEC requirements for arc fault Roof 2Azimuth:59O ¢ Po;t v.powNoutPut•eleanc¢ operating Temnerahrm -4o to as•e -' protection(AFC)and Photovoltaic Rapid f.w.<wxmatG�Wm' m`c j .aF,y {bp ",✓"$-s a � r°r- '"""°""nq" !Mitigates all types of module mismatch losses, Shutdown System(PVRSS) Panel Tilt. 180 Fire Performance Class L/Typal fro m d manufacturing tolerance to partial Umitetl Warranty' s a ing r Modufe-level voltage shutdown for Installer a 23-year z,ear po.,er ouw..t v:arrm`•v tr$ i�m_um,"inap -o^�°SN,1''1tl2gppy�'•; f Flexible system design for maximum space and firefighter safety maximum snow Loaa 1121Ds/fN(540.Pa) utilization .,•¢C^_-'..r SCY n r,.V t.r+s^t"•r A.a s „ Certaldrtied PE Stamps/Signatures C@- n~.NYN -,.�, P„ -0 a,i •�,nJ.a P2PH.iNaoazuT 3o kMcing•Pgprmg� rip H sdarPdge corn solar: ' t4 ® a -.n(ttl�lfry SAINT-GOSAIN - -_ - ' SAINT-GOBAIN Thomas Petersen Tom Petersen Architect,LLC I$Irlgle Phase Inverter 6CountryLane _ l Power Optimizer Howell NJ 07731 with HD-Wave Technology for North America For North America NY Architect License#035290 SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/ P320/P340/P370/P400/P405/P505 ° S-'i'hg1'&Phase Inverter ' z 'Z;V SE760OH-US/SE1000OH-US/SE1140OH-US �� its ,'H�D7W6v. a Te'hnology ` �� _` '�E"' -, _ y 14 V a ,C.U.r 0.'pn T.si> m+ i� 'Gro cUy7 YR a3:aV XKV Yl.'r_te Ne: 3.,S.Ofa1:3.V INPUT.,n pir .> - �� 11aG,unPLAce 0.ePr tYY) ii•'d,Z?4~ " !eR-f lin. -aU 10V1 yUle£26J ru n'r:•+,"+> - lA <�`.., r ✓e- , sfor Nod#Fi America, SESOpO�1''U ..§' =S380e0rH;Ls;jfl00H S/ 'SE7600H- SSE>10b00N=U5=%SE1`1400H-US cs e, d salma"d`•-P .,.,,,� - U �� ,;5 e �� Ctx�mtBtdF _ i rss.esaYCnw• I 1 I "% OUTPUT 0URW6OPERATION(POWER OPAM(1�P�CON.ECTEGTCOPEICATRIGSODUEEOGEQiYEATER7a,-S `6n, '0.� txn.w.h`�xl,(mny.nvuu, ,4.: - +x ob INPUT w ••�<.a�<u�u wr.,p.. E5 I w.ry - 4'kp ^:e S#7 Ixo ,):C7 nsr,OC,3+"q=1 SCS %5p OINVFInFR ORING STAND U>(1WER OPTIMIYER 015CONn1ECfFD FROMI-'+OLAREDG(jNVOl1El(OR 301ARE Gt�'`�=, Cn. '"i SS..e W S•M Q, .,vuyrx•- _ ,x,: •ui1 " d ;'`,yyi'®��•���;,« _ _ -, -�- r1:y-,.,Ix.v,'t+(wr�v x� �0 ar_%,v 1 :n Tvhs. .w= '1� --_ - <a cJ,n cs-sr c':`+o:x,nsz axix,_c<_'_a Rev Date Description Initial STANDARD COMPLIANCE I 00 12/2/20 Design MJ az u; v: rts m a =as z.:; r;;.` - -- - r(:��,.vo. .t�•>4t 01 12/11/20 Panel Change MJ z�z A, Z ,•`-<*r ri'gtL�`i" `+'• � ,•� ,- � -* .�� a „ 1x•,,.y.cc-c vlxiry.+„r,z,r+ro.�iY�p,.:hr` r 02 12/14/20 Panel Change MJ c_ wsmLunanspeancmwNS 03 04/29/21 As Built MJ Er ,O+'"-.'€ -��� .. <�' ^' +r '%' , !4.-,minird.•Errne, Y7 !44" —_ Is qq e i �° < " u3s N7l I Sl._5'i J+'.'f 5/ ^5..47.(! V9z2•L'at -„r n ✓f' Cf4+t>^uo6�i � , 3 �i A - ''TI ,,,,,,.,'�� �,H r3°/Ii ^lw t]t `al•f 3 -�/]i mr/b 1680 Westview Drive, r°^"",.rt :we���e.e:�+..>u.•`•,•�=r«•-,m a - rADOmONALFEATUREi 7�au"­ ,rn u•tnn _ , •it,;., ;, - = .,rn• _ Mattituck,NY 1192 ......:.mei-, _ -...x....,. _ _ ....w...-.. _ ..., f 4,sn�w,..e -If2S: ,:.mz•. G1 ._.m_ :J}A t\v. t1l39 .__ e i yvy-H:iJ11JxC ><„3r�.}" +S•65f-J-= 2l= _�'ic+eu ctR^.,s•r'�¢""�u�a,rx- _ _ Pea!*1N.tou Owner Orlowski Residence Optimized installation with HD-Wave technology STANDARD COMPLIANCE M - -- „„sr„ „�� Solar Modules (34)400W Modules a, xe — -- - - 5=w. Specifically designed to work with / Extremely small = s.�,e>u — —_L(_i,_,aims_____ _ ___ ^'•"<"" •'*- •-""'^" "•`"'` "" °P" `""""^`*" Solar Inverters (1)SE 11400H-US Inv power optrmrzers iNSTAUATiONSPECIFICATIONS phn ri+d=in` Solar S stem DC Size 13 6kW / Record-breatungBuilt-inn ency r Built- module level moniton9 xa.vJa e„s..r„•o;.,.y sr!tree- _ �24<, -•'s.e.^�„_ a xY Fir n"F.,;r.*=�-`•••tlsm px ,r ,_ ,<rir" •� Solar System AC Size 114kW / Fried voltage inverter for longer strings /outdoor and'ndoor installation -- .u9,`N.114 ,as.1,� • J.r-s 1;, ,• s Page Size 11"x 17" .ft, .51/rip '.irrq �yt•.r:'M1 ,aT, i}�a IXeY,t ttn,y—�-Lr__ Integrated arc fault prolecbon and rapid shutdown for /optional Revenue grade data ANSI[7210 NEC 2014 and 2017,per article 69011 and 69012 Class o 5(D 5%acwracy) _—_-______ -_—._—____ ___ _--___-___— —— _2% 1 1.11741 SA certified for CPUC Rule 21 gird hP,,,,v� _ •,;1� J.;1-+,cam _ SPEC SHEETS , ! compliance _ _ --_ +en:•a m..cays x - _ __ — —_ __ '� c.>, -i:,,..,-vnM•<r.s-,.,«c iv._s. E6-001.03 See Scales Page 7 of 8 soliredgecorl solar m ,.,..,s...r<_,.a r. ... -.,.f u.,,..>-. ,., F.. ,,: „..-...r-.,,,..,,«...............,.,......,.,,.........:,.,.,.,ra.......,,.`•-< „..,h,»..._,.. CE RoHS RoHS ^ � � Drafting/Design Firm no ,. FRA14E MODULE MOUNTING ` W1 FRAME MODULE MOUNTING : 01 PhRGD 0 11 MICRORAIL"' SFM suN MEW KED " SFM sum INSTALLATION GUIDE PAGE no MICRORAIL INSTALLATION GUIDE PAGE Viree management is performed after each raw cf mod�Ae5 is insWAed,Refer to wire,management seWon kpp,L&Ivi)for detaKed instiuctions. NY,NY 10004 (833)747-3639 ----------------------- Z:5 Developer LAY IN MODULIE(S): LAY IN MODULE(S): SEAT MODULE(S). Module should slide into catch features Ensure that modules are property seated .............. ........... �nitall.first two(2)modules on bottom row nstalt downhill end of module into the Triimra0l of the Trimrait-and module clips in cap and base ATTACH SPLICE FASTEN MODULES. TIGHTEN FASTENERS: and module clips first and then position uphill 2" Attach splice at intersection of two(2)modules Finish installing modules along row and tighten Tighten fasteners to 20 it lbs -PREMIERK)LARSOLURONS, microralLs to support modules Use attached splice if required per SFM D&E fastening bolts on microraits and splices to 20 ft Premier Solar Solutions Guide lbs after entire row is installed NOTEz Tighter remponrits in feao�qrjg order: Ensure minimum module engagement using 0 Moduli-cUm,�sockc,head czp-.crm tj�n 7 Connor Ln H, indicator marks 0 Orivetall.�mket head cap screw Deer Park,NY 11729 0 (631)482-8303 ADJUST MICRORAIL CAP DOWN TO ENGAGE WITH MODULE: W th microrail.pressed against module I.Appty downward PROPERTY INFORMATION pressure to module side of cap which will 2 separate Tax Map: 1000 107000700019000 cap from base on capture side and allow cap to 3.contact module and 4.simultaneously re-engage to base at corresponding module height location Roof I Azimuth.239' Roof 2 Azimuth:59' 40 mir J��3.im- and 11 rrirri VERIFY CORRECT POSIT"OF CAP: Panel Tilt: 18' Check p tion and verify cap on down-stope side is tight ATTACHED SPLICE ADJUSTMENT: gap between cap and module after tightening bolt I With 1/4*hex drive tooL rotate height adjustment height adjustment feature head with clearance with no osi Tower and height adjustment feature may be Located to alternate position as required to achieve feature clockwise until head clears thru-hole in hote.3 Rotate height adjustment feature counter- minimum module engagement base 2 slide tower to alternate position and arign clockwise unlit head enters clearance hole. I PE Stamps/Signatures Thomas Petersen Tom Petersen Architect,LLC PART 4 TA13LE PART#TABLE 6 Country Lane PIN DESCUPTION P/N DESCRIPTION Howell NJ 07731 SFM MICRORAIL 2" 125002OU ISFMMICRORML2- 25003OU I SFM ATTACHED SPLICE 8' NY Architect License 035290 SFM ATTACHED SPLICE 8" SEE PAGE SFM-A03 V FM SEE PAGE SFM-A06 5 1/16 S SPLICE 6.5" S_ATTAC SEE P ED AG PAG FM CE FM- 02 SLIDER COMP DARK SEE PAGE SFM-A1O S EE EE PAGE SFM-PO1 Rev Date Description Initial FLASHKrr SFM TRIM COMP DARK SEE PAGE SFM-AO4 00 12/2/20 Design Mi 01 12/11/20 Panel Change Mi 02 12/14/20 Panel Change Mi 03 04/29/21 As Built Mi 1680 Westview Drive, Mattituck,NY 11952 MLPE MOUNTING ASSEMBLY WIRE BONDING CLIP Owner Orl6wski Restclence SEE PAGE SFM-A1I SEE PAGE SFM-Al2 SFM ATTACHED SPLICE 8" Solar Modules (34)40OW Modules N/S BONDING CLAMP TRIM BONDING CLAMP SFM MICRORAIL 2" Solar Inverters (1)SE 1140OH-US Inv SEE PAGE SFM-Al2 SEE PAGE SFM-Al2 0 SCALE PRODUCT LINE: , FM INFINITY DRAWING NOT TO SCALE PRODUCT LINE. I SFM I rn Solar System AC Size 114 kW 0 S ARE ale PUNIRAC ALL DIMIENSIAL C> d RTS ALL DIMENSIONS ARE :0 ALL DIMENSIONS ARE DRAWING TYPE ASSEMBLY NOMINAL IF DRAWING TYPE:I PA ASSEMBLY NOMIM DRAWING TYPE I PARTS A-rFMR1 V NOMINAL Page Size I V x 17" 1411 BROAOWAYBLVD NE ExAMpLE PRODUCT PROTECIED BY a- 1411 BROADWAY BLVD.NE 1411 BROADWAY BVJD NE — 2: ' ` . ALBUQL1ERqJE,N1M11I121SA DESCRIPTION LAYOUT U) ALBUQUERQUE,NM 87102 LGA DESCRIPTION. 1 MICRORAIL 2- PRODUCT PROTE W By ALBUQMQUE,NM 87102 M SPLICE 8" PRODucr PROTECTED BY' -PHONE B,"2 6411 ONE OR MORE US PATENTS PHONE 505 242 6411 — NE OR MORE USC;ATENTS PHONE 5052426411 ONE OR MORE US PATENTS SPEC SHEETS CONT. ` Q LEGAL NOTICE SHEET WWW LINIRACCOM REVISION DATE:1 4/22/2019 WINN UNIRACCMI REVISION DATE 4122/201 10 1 FrAl KInT WWW UNIRAC COM REVISION DATE 14/22/2019 LEGAL N017CE I STEE7 Scale See Scales I Page 8 of 8 ` . � -- Drafting/Design Firm Labels comply\N ith NEC 110 21(B)and ANSI Z535.4 PhRGD INVERTER(DC DISCONNECT) �- •' COMBINER PANEL • ® ® ® •• ® INVERTER 25 NY,road 10004Floor ' P t i" aY'� ' ri ; ri�� 3 , � i /�,[ � �' COMBINER PANEL � `\\ L. .gyp.��;=, �� rt;> ® A/C DISCONNECT (833)747-3639 ELECTRIC SHOCK HAZARD A/C DISCONNECT DUAL POWER SOURCE Developer DO NOT TOUCH TERMINALS DO NOT INSTALL ADDITIONAL INVERTER TERMINALS ON BOTH THE LINE JUNCTION BOX LOADS IN THIS PANEL ® • AND LOAD SIDES MAY BE A/C DISCONNECT a^` ENERGIZED IN THE OPEN POSITION INVERTER jW INVERTER(DC DISCONNECT) COMBINER PANEL ® ® ® D/C DISCONNECT PREP°ilEP,,SO LAR SOLUTIONS Premier Solar Solutions JUNCTION BOX MAIN DISTRIBUTION 7 Connor Ln H, ELECTRIC SHOCK HAZARD INVERTER OUTPUT CONNECTION Deer Park,NY 11729 CONDUIT EVERY 10 FT (631)482-8303 THE DC CONDUCTORS OF DO NOT RELOCATE THIS THIS PHOTOVOLTAIC OVERCURRENT DEVICE JUNCTION BOX SYSTEM ARE UNGROUNDED PROPERTY INFORMATION AND MAY BE ENERGIZED Tax Map: 1000107000700019000 as irA', COMBINER PANEL Roof 1 Azimuth.239° INVERTER(DC DISCONNECT) 1�,� i ® t, A/C DISCONNECT Roof 2 Azimuth:59° DUAL POWER SOURCE 0 Panel Tilt- 18° ELECTRIC SHOCK HAZARD TOTAL RATING OF ALL OVERCURRENT IF A GROUND FAULT IS INDICATED, DEVICES,EXCLUDING MAIN SUPPLY NORMALLY GROUNDED OVERCURRENT DEVICE,SHALL NOT CONDUCTORS MAY EXCEED AMPACITY OF BUSBAR BE UNGROUNDED AND ENERGIZED • ® • ® MAIN DISTRIBUTION PE Stamps/Signatures ®® ® ® • Thomas Petersen ® ®® ® ® Tom Petersen Architect,LLC l A tn' 6Country Lane COMBINER PANEL '® ® ®° ® s a J1 '� =` 1y; MAIN DISTRIBUTION PANEL • . . W Howell NJ 07731 NY Architect License#035290 DUAL POWER SOURCE • ®® ARC FLASH HAZARD • • • •p. APPROPRIATE PPE REQUIRED TWO POWER SOURCES INSIDE ® 0 FAILURE TO COMPLY CAN RESULT IN UTILITY AND SOLAR P V INJURY OR DEATH REFER TO NFPA 70E Rev Date Description Initial 00 12/2/20 Design MJ 11.41l SE INVERTER#1 01 12/11/20 Panel Change MJ 02 12/14/20 Panel Change MI 03 04/29/21 As Built MJ ® .00 1680 Westview Drive, 11 14,11 Mattituck,NY 11952 • ® • Owner Orlowski Residence Solar Modules (34)400W Modules Solar Inverters (1)SE 1140OH-US Inv Solar System DC Size 13 6kW Solar System AC Size 11 4 kW Page Size I1"x 17" LABELS Scale See Scales Page 5 of 8 L-000.03 Drafting/Design Firm 1 ATTACHMENT DETAILS ROOF LAYOUT s Scale MS PhRGD o © 25 Broadway 9th Floor Scale. 1-10'-0" -- — NY,NY 10004 A—T TC all<ROPar uv oavni EnEacE mrx rao ouE (833)747-3639 '<�E x"� `�:ta �ule mea srta amwsry re<�9evvasea�a I � � powi-g moeveMign loo Developer 1�jm ( j,r yx I yEpl VCORRERPOSfrIONOF AP I ( y 4 Premier Solar Solutions 2 -- - `~ ---- `---— 7 Connor Ln H S-000 Deer Park,NY 11729 FASTENMODULES. TIGHTEN FAS • inis fh mstalUng modules along row and tighten Tighten fastenersners to[0 20 ft 165 (631)482-8303 fastening bolts on microads and splices to 20 ft ,s lbs after entire row is Installed MUTE Tichn.it.zHrlarsYrts m fatlumng oiaer. '�, ♦ �„t r 0 M.d'le camp sakes head cap s cvt V'- ,` Et Pioretad socket head saP screw PROPERTY INFORMATION Tax Map: 1000107000700019000 VyS, ;.' Roof 1 Azimuth 239° 2 RACKING DETAILS 1V �10 Seale NTS Roof 2 Azimuth:59° J s y ej rE° n \` �O SFM Mlcrpraa 2^ Panel Tilt: 18° a° "' %- � 'fes ', t "; ✓� SFM Attached Splice 8" = ,46 � i %` k' "a SFM Attached Splice 65" o°z3h PE Stamps/Signatures r � `,-„•,`s "���, Thomas Petersen � . Tom Petersen Architect,LLC 6 Country Lane Howell NJ 07731 °a��• NY Architect License#035290 Flashkit SFM SFM Trunrad Splice Slider COMP Dark SFM Trimrad ' 'U % Flashkit SFM Tnm Comp Dark , 3 STRUCTURAL DETAILS Scale I/8"=I'-0'• Rev Date Description Initial 00 12/2/20 Design MJ 1� 01 12/11/20 Panel Change MJ 02 12/14/20 Panel Change MJ 1 O _ 03 04/29/21 As Built MJ 1 l 2"X 8"Ridge Beans Solar Panel Installation 2”x 6"Rafters 16"o c 1680 Westview Drive, LEGEND u' Mattituck,NY 11952 Owner Orlowski Residence s"ia P Rd 2" 4'.3" 3 \ \ \ Solar Modules (34)40OW Modules 6 �J Solar Inverters (1)SE1I40OH-US Inv Budd,.,Outbnc 13' Solar System DC Size li 6kW y Solar System AC Size 114 kW I, v..'P.N Page Size I I"x 17" �bamRr, ROOF LAYOUT& DETAILS NOTE Scale See ScalesPage 3 of 8 PLEASE CONFIRM ROOF DIMENSIONS ON SITE BEFORE INSTALL S-000 .03 Drafting/Design Firm SOLAR PV ELECTRIC GENERATION SYSTEM INSTALLATION ON EXISTING RESIDENCE: PhRGD 1680 Westview Drive Mattituck➢ QTY 11952 25NYdNY 100`0Floor (833)747-3639 ' „ , n`: Site Plan 1'" Scale: 1 = 15 _T� Aerial Map Developer - 4 f r 14' / h$ PiemierSolai Solutions / ts, �= 7 Connor Ln H, ��t-5 n � �, Deer Park,NY 11729 z� (631)482-8303 PROPERTY INFORMATION \ / Tax Map 1000107000700019000 Roof 1 Azimuth:239 / Proposed Solal ;`, / Roof 2 Azimuth:59° Panel Installation Tax Map Panel Tilt 18° PE Stamps/Signatures .: Thomas Petersen ,LLC5Front f Tom Petersen Architect 3 Residence 6 Count Lane `sus Howell NJ 07731 '= == ` NY Architect License#035290 101-611 1 Drivewayal r JJ Legend rr✓Proposed Sola �� r Iectrical Installation Rev Date Description Initial Solar Panel 00 12/2/20 Design M1 co � � � wi a��:I;,��° ,v u• 01 12/11/20 Panel'Chan�e MJ 02 12/14/20 Panel Chane M1 03 04/29/21 As Built MJ r r N Solar Inverter/Electrical Equipment 1 1680 Westview Drive, MattDRAWING INDEX Owner u to NY 119 2 APPLICABLE CODES SCOPE OF WORK NOTES Owner Orlowski Residence Building Outline Solar Modules (34)400W Modules I Zoning Information,Site Plan Z-000.00 All materials,equipment,installation and work shall 2 System Layout A-000 00 comply with the following applicable codes SCOPE OF WORK IS SOLELY FOR THE Pei attached sn uctar aanalysis letter,the y l l Solar inverters (1)SE l 140OH-US Inv r Vent Pi INSTALLATION OF THE SOLAR existing r oof sn uctur e,with upgrades where .1 pe Solar System DC Size 13 6kW 3 Roof Layout&Details S-00000 ELECTRONIC GENERATING SYSTEM ALL necessai y,is capable of supper ting the loads of the solar'elects teal generating system Solar System AC Size 1 l 4 kW 2017 National Electrical Code OTHER WORK IS NOT TO BE RELIED UPON Page Size l I^x 17^ 4 Electrical 3-Line&1-Lme E-000 00 2015 International Residential Code AS BEING APPROVED AND/OR PERMITTED BY THE BUILDINGS DEPARTMENT For Tenant Safety,Elecn icnl,and Install Cltlmney ZONING INFORMATION, 5 Labels L-000 00 2020 New York State Residential Code notes please see page G-000 00"Gene,a! SITE PLAN 2020 New York State Building Code Notes" 6 General Notes G-000.00 2020 NYS Fire Code Scale-See Scales Pale 1 of g 7 Specifications Sheets G-001 00 2015 International Fite Code 8 Specifications Sheets Continued G-002 00 Z-000.03 Drafting/Design Firm SYSTEM LAYOUT PhRGD Scale: V=8'-011 25 Broadway 9th Floor NY,NY 10004 - (833)747-3639 LEGEND Developer Solarpeall .,: FD Setbacks&Pathways caa ane - t`_:'V` (D� -- ea— DIC Home RunChimney _ n - • - --.r— A/C Home Run '4s _ , - ° -- t PREMIERSOL�iR501UIlONS Light Shade - ,. - _ , _ , Hea�rshaae ° Roof 2 �'° Premier Solar Solutions ^ O 7 Connor Ln H, r (28) Certa>inTeed Deer Park,NY 11729 obawennn(Vrnt Pipe) , - - - , - - „ - ., (631)482-8303 Db..agGW/ ,,, 390W Solar Panels ° • , , -, S.I.invenWEI.M.1 Egmpment r PROPERTY INFORMATION 0 vent Pipe Tax Map: 1000107000700019000 FO chmnry Azimuth: 59° Roof 1 Azimuth:2390 Roof°1 ` Slope: 18°4 (6) CertainT_ee`cl : � °'� � , Roof 2 Azimuth:s9° 390W.Soi Panels' - s 16"Vent Box,to Panel Tilt: 18° Roof Notes - . . ' Roofing Material:Composite Shingle _ "i be relocated PE Stamps/Signatures Thomas Petersen Azimuth: 239° i' Tom Petersen Architect,LLC Slope: 1 g° 3 Vent Pipe,to ' _ be relocated 6 Country Lane 1� T Howell NJ 07731 NY Architect License#035290 DA e L, `-Front of ; :Residence 9j a3529� 0 ry -., - yam._° , ^Pqi°',` ,J J _ er � _- � -• _ Rev Date Description Initial - `k t2l �' .00 12/2/20 Design M7 01 12/11/20 Panel Change MJ 02 12/14/20 Panel Change M7 14-l"1400H'=US,SE snvert6r`#1` < j.;. f' 1680 Westview Drive, =lDrivewa s oas . ARE Y `r'j « _ �_ Mattituck,NY 11952 .ACDi�eorinect Switch, Owner.Orlowski Residence .; s u, Solar Modules 34 390W Modules nH"�e_:.a,! d _ Solar Inverters: 1 SE 114 H- Inv 00 US a to Size. 2k Solar System 13. W e So az System AC Size: 1 W r' € = 1 y 1 4 k in Phase'Util' eter3 Wii T - S gle =` s, y Pa eSize 11"x1T' _ - - `DisconnectrSwitchy� ��' , LAYOUT T U Scale:See Scales Pa e 2 of 8 g SCALE:1"=8.0" IN FEE t T) ';<i- _ . . _ ;G{ ' For Tenant_Safe °'Electrical,and Installationw '8 tes, a a e e t no le se'see G-000'00 Gen rel No e' s p A—000.02 - - P g 0 DraftffiWDesign Firm 1 ATTACHMENT DETAILS ROOF LAYOUT S Scale NTS -jur"hhRGD, a 25 Broadway 9th Floor Scale: 1"=10'-0" NY,NY 10004 © i; ��� � wmsrwaoxsraooawarocucscvwrtasioouc (833)747-3639 vnmmsromnsMsma wows mmw s. ."vm � sRs+m.mmomne uaemno»*aana aseo"au Developer ;� Y I � `LJ'°4 at (��` vwzrmnuawvnoH a.w (�—�4� t�g5� �(r^--�7_ 6,L Pts^!maiimm p�yVy�Um udbt7�YmticxrtYOWWeh UBM ) Ilfi X1;1 l��l nll__l;��6 wMmYDhtwen�auoM le+M�kU>miM 6W[ 4 F POEMIEl SOLARso m s <� ®� Premier Solar Solutions 2 7 Connor Ln H, ,`a s-000 Deer Park,NY 11729 FASTEN MOTIGHTEN FASTENERS: (631)482-83 03 � Finish installingling modules along row and tighten Tighten fasteners to 20 h lbs fastening bolts an micromils and splices to 20 ft �t lbs after entire row is Installed NOTE:Tighten components In following order: ®Module clamp socket head cap screw than ©0matalt sodtet head cop warn� O PROPERTY INFORMATION Tax Map: 1000107000700019000 qi RACKING DETAILS Roof 1 Azimuth:239' Seale NTS Roof 2 Azimuth:59' SFM Microrail2" Panel Tilt: 18' A r✓� SFM Attached Splice 8" SFM Attached Splice 6.5" r' PE Stamps/Signatures 4 Thomas Petersen cj Tom Petersen Architect,LLC 6 Country Lane a Howell NJ 07731 NY Architect License#035290 DAR `�' Flashkit SFM SFM Trtmrail Splice (ryes F.Pe Slider COMP Dark O is SFM Trtmrail * n b i l r Flashkit SFM Trim Comp Dark 0352913 Q ' SOF NE+TIy ti� s-000 STRUCTURAL DETAILS Scale I Rev Date Description Initial 00 12/2/20 Design MJ 1rj 01 12/11!20 Panel Change MJ 02 12/14/20 Panel Change MJ l 2"X 8"Ridge Beam Solar Panel Installation 2"X 6"Rafters 16"o c 1680 Westview Drive, LEGEND is Mattituck,NY 11952 Owner.Orlowski Residence Solar Modules:(34)390W Modules Solar Inverters:(1)SE 1140OH-US Inv a"dd.gomhae Solar System DC Size:13 2kW 13' Solar System AC Size:11.4 kW jQ_I v—Pw Page Size:I1"x17" [C U- ROOF LAYOUT& DETAILS NOTE' Scale:See Scales I Page 3 of 8 PLEASE CONFIRM ROOF DIMENSIONS ON SITE BEFOREINSTALL —0 0 .02 1-LINE DIAGRAM Drafting/Design Firm Grid Meter To CertamTeed Mono Panel ASHRAE High Low Temps Building Maximo Pow PhRGD, Maximum Power.390W+0-5W NY,NY High=33°C I I Open-Circuit Voltage:48.2V NY,NY Low=14°C Short-Circuit Current:10.5A 25 Broadway 9th Floor Voc Temp Coefficient:-0.31%/C° NY,NY 10004 Vpmax:40AV Voc Low Temp,(VocLow)=48.2V-{-0 149V/C*[25C0-(-14C0)]1=54.OV (833)747-3639 89L A/C Ipmax 9.7A Vmp High Temp=40.4V-{-0.149V*[25C°-(33C°)3}=39.2V SolazEdge Disconnect MAIN PV Array I SE114000H-US DISCONNECT I Developer SolazEdge Inverter SE1140OH-US x Max Pdc:17650 IN Max Vin:480 V SolazEdge Optimizer I Max Isc m'45A A/C Disconnect Switch TOMax Pao:11400 W P400 SQUARE D 60A Rated JIM EXTERNALI Max lout Continuous.47.5A Max Vin.80V 60A Fused Disconnect PRE MIERSOLAR SOLUTIONS ' CIRCUIT I GFDI Threshold:1 Max Isc:10.IA 240/120V 3 Wire Max Vour 60V UL Listed Approved Premier Solar Solutions SIDE OF Max Iout:15A Knife Switch 7 Connor Ln H, ROOFTOP I GARAGE I BUILDING Deer Park,NY 11729 (631)482-8303 3-LINE DIAGRAM PROPERTY INFORMATION I I Tax Map: 1000107000700019000 Key I I Roof 1 Azimuth:239° V I I Roof 2 Azimuth:59° Positive ROOF I GARAGE GARAGE I SIDE OF BUILDING Panel Tilt: 18' Negative Ground I (1)Ll#6 CU Conductors THWN-2(Minimum)(or Equivalent) L 1,L2 (1)L2#6 CU Conductors THWN-2(Minimum)(or Equivalent) PE Stamps/Signatures (1)Neutral#6 CU Conductors THWN-2(Minimum)(or Equivalent) Neutral I (1)Grounding#8 CU Conductors THWN-2(Minimum)(or Equivalent) I Thomas Petersen 3/4"EMT Conduit(Minimum)(or Equivalent) I Tom Petersen Architect,LLC 6 Country Lane To Grid Howell NJ 07731 NY Architect License#035290 3 Strings (34)Certain Teed 390W Panels (34)P400 Optimizers SolarEdge Point of Interconnection SE1140OH-US IPC Connectors 250 VAC rated UL Listed I String I MP1 I nic A/C 89L 60A A/C 10 Mods Disconnect l0 Optimizers D/C I 19 Load Side I Bi-Directional Utility Meter 200A 240V Single Phase 00 Cutler-Hammer( 120V 3 Wire Knife Main I Meter#098296789 Switch L Disconnect Rev Date Description Initial String 2 6/C A/C ++60A I .00 12/2/20 Design MI MPI I To External I .01 12/11/20 Panel Change MJ 12 Mods I .02 12/14/20 Panel Change MJ 12 Optimizers Circuit I C:; 1680 Westview Drive, String 3 I I Mattituck,NY 11952 MPI I (3)Positive#10 Conductors PV Wire I Owner.Orlowski Residence 12 Mods (3)Negative#10 Conductors PV Wire 12 Optimizers I (1)Grounding#10 Conductors PV Wire 1)Grounding#6 I Solar Modules-(34)390W Modules 3/4"EMT Conduit - Conductor I Solar Inverters:(1)SE 1140OH-US Inv Existing Building Ground I Solar System DC Size.13.2kW elf Bonding Panel and Rail - Solar System AC Size:11.4 kW (1)Ll#6 CU Conductors TH -2(Minimum)(or Equivalent) I Page Size 11"x 17" (1)L2#6 CU Conductors THWN-2(Minimum)(or Equivalent) I ELECTRICAL 3-LINE& (1)Neutral#6 CU Conductors THWN-2(Minimum)(or Equivalent) (1)Grounding#8 CU Conductors THWN-2(Mimmum)(or Equivalent) I 1-LINE 3/4"EMT Conduit(Minimum)(or Equivalent) I Scale:See Scales Page 4 of 8 E-000 .02 Drafting/Design Firm Labels comply with NEC 110.21(B)and ANSI Z535.4R D G F�_ - x. .•�_-- F.-�- -�s• » .»• 25 Broadway 9th Floor R' INVERTER(DC DISCONNECT) �'1/� T (�� COMBINER PANEL ® m t'" '110 pip vmige, INVERTER NY,NY 10004 AWA " N'!� '� A;V�"l U 1,,C�I V± rn, + " 4 ©o l _ A/C DISCONNECT COMBINER PANEL =: �„ a, - (833)747-3639 FELECTRIC SHOCK HAZARD A/C DISCONNECT DUAL POWER SOURCE Developer DO NOT TOUCH TERMINALS. DO NOT INSTALL ADDITIONALfi -, a r t _ _ f; - INVERTER TERMINALS ON BOTH THE LINE JUNCTION BOX LOADS IN THIS PANEL A/C DISCONNECT AND LOAD SIDES MAY BE -= `= E ENERGIZED IN THE OPEN POSITION INVERTER COM 'u PREMIERS 0 LARzwnm INVERTER(DC DISCONNECT) BINER PANEL D/C DISCONNECT Premier Solar SolutionsJAWARNING] JUNCTIONBOX AWARNIN MAIN DISTRIBUTION 7 Connor Ln H, ELECTRIC SHOCK HAZARD INVERTER OUTPUT CONNECTION Deer Park,NY 11729 _ CONDUIT EVERY 10 FT (631)482-8303 DO NOT RELOCATE THIS , JUNCTION BOX THE DC CONDUCTORS OF s � tl Ij�� j�P ��(D ` THIS PHOTOVOLTAIC OVERCURRENT DEVICE SYSTEM ARE UNGROUNDED PROPERTY INFORMATION AND MAY BE ENERGIZED Tax Map: 1000107000700019000 INVERTER(DC DISCONNECT) ® �►M A R N'1 COMBINER PANEL 1pew Roof 1 Azimuth:239° G ] F,A, JA '(�, Ar 0=w t-�.- A/C DISCONNECT Roof 2 Azimuth:59° \I Y 1�I DUAL POWER SOURCE SKI AL 00 M6 a�°_Wo A�M.2W Panel Tilt: 180 ELECTRIC SHOCK HAZARD TOTAL RATING OF ALL OVERCURRENT IF A GROUND FAULT IS INDICATED, DEVICES,EXCLUDING MAIN SUPPLY NORMALLY GROUNDED OVERCURRENT DEVICE,SHALL NOT CONDUCTORS MAY EXCEED AMPACITY OF BUSBAR � MAIN DISTRIBUTION PE Stamps/Signatures BE UNGROUNDED AND ENERGIZED WANW ` HAPAM D(0)WON T(Q)�KeH��&A Thomas Petersen 7M AE-ev `1 F.]N19 me U AD Tom Petersen Architect,LLC am"Ali BE HU's)lei TM am 6 Country Lane e COMBINER PANELHowell NJ 07731 A T MAIN DISTRIBUTION PANEL ' �° ��� � NY Architect License#035290 ARC FLASH HAZARD DUAL POWER SOURCE APPROPRIATE PPE REQUIRED. TWO POWER SOURCES INSIDE GSC'V00�1� to hoJ FAILURE TO COMPLY CAN RESULT IN UTILITY AND SOLAR PV INJURY OR DEATH.REFER TO NFPA 70E. Rev Date Description Initial .00 12/2/20 Design MJ C§lJQtEaJ 'FH=0 0DV(Q%l`jl°ArC MVMKXXC1 11.4kW SE INVERTER#1 .01 12/11/20 Panel Change MJ M1m� A .02 12/14/20 Panel Change MJ UM MWER POW VOLTM9,QW K&A affm 1680 Westview Dnve, Mattituck,NY 11952 Owner.Orlowski Residence Solar Modules:(34)390W Modules Solar Inverters-(1)SE 1140OH-US Inv Solar System DC Size:13 2kW Solar System AC Size.11.4 kW Page Size.I I"x 17" LABELS Scale:See Scales Page 5 of 8 L-000 .02 Drafting/Design Firm CONTRA T R NOTES EQUIPMENT NOTES ABBREVIATIONS P"hRGD 1 THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE SYSTEM DESIGN 1. ALL MATERIALS,SUPPLIES,AND EQUIPMENT SHALL BE LISTED,USED,AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S A AMPERES 25 Broadway 9th Floor ENGINEEROF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS RECOMMENDATIONS AND INSTRUCTIONS,AND APPLICABLE NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL)REQUIREMENTS. AC ALTERNATING CURRENT NY,NY 10004 2. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL WORK AS SHOWN IN THE CONSTRUCTION 2 ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH 1T IS INSTALLED. AF AMP AFDI ARC FAULTETECTION INTERRUPTER (833 747-3639 DOCUMENTS UNLESS OTHERWISE NOTED.ALL WORK SHALL BE PERFORMED IN AN ORDERLY, WORKMANLIKE AND SAFE MANNER BY WORKERS SKILLED AND EXPERIENCED IN THEIR TRADES 3, WORKING SPACE AROUND ELECTRIAL EQUPMGNT SHALL COMPLY WITH NEC 110 26 AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH Developer 3, ALL REQUIRED AND NECESSARY PERMITS SHALL BE SECURED FROM ALL MUNICIPAL AGENCIES HAVING 4. THE APPROXIMATE LOCATIONS OF ALL JUNCTION BOXES,COMBINER BOXES,CONDUITS,ETC.SHALL BE DETERMINED FROM THE AWG AMERICAN WIRE GAUGE N JURISDICTION AT THE COST AND EXPENSE OF THE CONTRACTORS PRIOR TO THE START OF WORK. DRAWINGS,AND VERIFIED BY THE CONTRACTOR FOR INSTALLATION HIL BASIC IMPULSE LEVEL 5 ALL JUNCTION BOXES,COMBINER BOXESAND DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. BIB BYPASS ISOLATION BREAKER , 4, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL INSPECTIONS TO BE WITNESSED BY BPS BOLT PRESSURE SWITCH �0THE AHJ AND/OR THE OWNER THE CONTRACTOR SHALL WORK WITH THE OWNER'S INSPECTION AGENCY 6 PROVIDE NEMA 3R RATED EQUIPMENT OR BETTER WHERE EXPOSED TO OUTDOORS CA CIRCULAR MILS AREA -i '► TO PLAN THE INSPECTIONS,AND NOTIFY ALL PARTIES INVOLVED SUFFICIENTLY IN ADVANCE TO ALLOW CB COMBINER BOX THE INSPECTIONS TO TAKE PLACE IN A TIMELY MANNER AND NOT DELAY THE PROGRESS OF THE WORK7 WHERE SIZES OF RACEWAYS OR BOXES ARE NOT INDICATED ON THE DRAWINGS,THE CONTRACTOR SHALL SIZE THESE ITEMS AS COMM COMMUNICATIONS _ THE OWNER AND SYSTEM DESIGN ENGINEER WILL NOT BE RESPONSIBLE FOR SCHEDULING,ARRANGING REQUIRED FOR THE INSTALLATION CT CURRENT TRANSFORMER - OR COORDINATING THE INSPECTIONS CP CONTROL PANEL 5 CONTRACTOR SHALL FURNISH ALL NECESSARY BOXES,OUTLETS,SUPPORTS,CONDUITS,FITTINGS,AND 8 ALL VERTICAL RUNS OF CONDUIT OR TUBING TERMINATING IN THE BOTTOM OF WALL BOXES OR CABINETS OR SIMILAR LOCATIONS, CPT CONTROL POWER TRANSFORMER PkE f"iER'S O LA 'SC3 uvol s SHALL BE PROTECTED FROM THE ENTRANCE OF FOREIGN MATERIAL PRIOR TO THE INSTALLATION OF CONDUCTORS ACCESSORIES TO FULFILL APPLICABLE CODES,REGULATIONS,BUILDING STANDARDS,AND THE BEST CU COPPER PRACTICE OF THE TRADE FOR THE INSTALLATION OF ELECTRICAL WORK CO CONTINUOUS OPERATION CURRENT Premier Solar Solutions 9 METAL RACEWAYS,METAL ENCLOSURES OF ELECTRICAL DEVICES AND EQUIPMENT,MODULE FRAMES,AND OTHER EQUIPMENT SHALL 7 Connor Ln H BE COMPLETELY GROUNDED IN ACCORDANCE WITH THE NEC.PROPER HARDWARE FOR A COMPLETE GROUNDING AND BONDING CYC CYCLE , 6 THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS WHOSE WORK MIGHT SYSTEM SHALL BE INSTALLED BY THE CONTRACTOR,IF NECESSARY D DISTANCE Deer Park,NY 11729 AFFECT THIS INSTALLATION.CONTRACTORS SHALL ARRANGE ALL PARTS OF THIS WORK AND EQUIPMENT DC DIRECT CURRENT 631 482-8303 IN PROPER RELATION TO THE WORK AND EQUIPMENT OF OTHERS AND WITH BUILDING CONSTRUCTION 10 GROUNDING RODS SHALL HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS AND SHALL BE 5/8"x 8'MIN,COPPER-BONDED STEEL DISC DISCONNECT AND ARCHITECTURAL FINISH SO THAT IT WILL HARMONIZE IN SERVICE AND APPEARANCE. ALL GROUND CLAMPS USED SHALL BE UL 467 LISTED. EDP EMERGENCY DISTRIBUTION TRANSFORMER EGC EQUIPMENT GROUNDING CONDUCTOR I I ALL PVC CONDUIT EXPOSED TO SUNLIGHT SHALL BE SCHEDULE 80 AND MARKED AS SUNLIGHT RESISTANT ALL UNDERGROUND PVC EHDP EMERGENCY HIGH VOLTAGE DISTRIBUTION CONDUIT SHALL BE SCHEDULE 40 OR 80 PANELBOARD PROPERTY INFORMATION TENANT SAFETY NOTES ELDP EMERGENCY LOW VOLTAGE DISTRIBUTION PANELBOARD Tax Map: 1000107000700019000 EMT ELECTRICAL METALLIC TUBING 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING THE AREAS WHERE WORK 1S TAKING PLACE,AS WELL EPR ETHYLENE PROPYLENE RUBBER AS ANY ADJOINING AREAS WHICH MAY BE AFFECTED BY THE WORK,TO PREVENT SUBJECTING THE OCCUPANTS, EQUIP EQUIPMENT Roof 1 Azimuth:239° STRUCTURES,VEHICLES,EQUIPMENT,OR ANY OTHER PARTS OR CONTENTS OF THE SITE TO HAZARD OR DAMAGE ELECTRICAL NOTES EXIST EXISTING GND GROUND Roof 2 Azimuth:59° 2 CONSTRUCTION SHALL BE PERMITTED DURING NORMAL BUSINESS HOURS SAM TO 5PM AND SHALL NOT EXCEED GFCI GROUND FAULT CIRCUIT INTERRUPTER PAST THESE TIMES I ELECTRICAL POWER MUST BE SHUT OFF PRIOR TO THE CONTRACTOR PERFORMING ANY WORK IN RACEWAYS WITH LIVE ELECTRICAL GED GROUND FAULT DEVICE Panel Tilt: 18° CIRCUITS OR ANY OTHER EQUIPMENT.WHEN SWITCHES OR CIRCUIT BREAKERS ARE OPENED FOR WORK ON ELECTRICAL EQUIPMENT OR HWG HEATER WATER GAS LINE WILING,SIGNS OR TAGS SHOULD BE INSTALLED AT THE SWITCH OR BREAKER STATING THAT WORK IS BEING PERFORMED ON THEM INV INVERTER 3, THE CONTRACTOR SHALL,AT ALL TIMES DURING THE WORK,MAINTAIN ACCESSIBILITY FROM THE STREET TO ALL INCLUDE THE TIME,DATE,AND CONTRACTOR'S NAME ON THE SIGN OR TAG 1F DEVICE IS LOCKABLE,IT SHOULD BE PADLOCKED Ipmax NOMINAL CURRENT(AMPS) FIRE HYDRANTS,POWER OR LIGHT POLES,AND SIMILAR UTILITY AND PUBLIC SERVICE ITEMS WITHIN OR ADJACENT IMC INTERMEDIATE METAL CONDUIT 2 THE ELECTRICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE AHJ,NATIONAL FIRE PROTECTION AGENCY(NEPA),NATIONAL TO THE CONSTRUCTION SITE KCMIL THOUSAND CIRCULAR MILS ELECTRICAL CODE(NEC),AND OSHA KV THOUSAND VOLT 4 WORK SHALL NOT RESTRICT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUITION FACILITIES(POWER POLES,PULLBOXES,TRANSFORMERS,VAULTS,PUMPS,VALVES,METERS,APPURTENANCES, 3 PHASING OF NEW CONDUCTORS TO MATCH EXISTING CONDUCTORS.IF INSTALLATING A NEW CIRCUIT,THEN CONTRACTOR SHALL KVA THOUSAND VOLT-AMP PE Stamps/Signatures ETC.)OR TO THE LOCATION OF THE HOOKUP FOLLOW THE PHASING SCHEMES PROVIDED IN THE ELECTRICAL DIAGRAM KW THOUSAND WATT LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT Thomas Petersen 5 THE OWNERS AND THE AHJ SHALL BE NOTIFIED IN WRITING IN ADVANCE OF ANY REQUIRED CONSTRUCTION 4 ALL CONDUCTORS SHALL BE COPPER,RATED FOR 90°C WET ENVIRONMENT,AND 1000 VOLTS DC OR 600 VOLTS AC,UNLESS OTHERWISE LSC SHORT CIRCUIT CURRENT Tom Petersen Architect,LLC OPERATION THAT WILL INVOLVE INTERRUPTION OF THE HEATING,WATER,FIRE PROTECTION SYSTEMS, NOTED. LSIG LONG,SHORT,INSTANTANEOUS,GROUND TELEPHONE,GAS OR ELECTRICAL SERVICES TO THE OTHER BUILDINGS AND AREAS OF THE SITE.THE CONTRACTOR TIME 6 Country Lane 5 EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A SHALL COORDINATE ANY REQUIRED SHUTDOWN OF THE UTILITIES WITH THE OWNERS,THE AHJ,AND THE UTILITY MAU MAKEUP AIR UNIT COMPANY. RACEWAY OR CABLE ARMOR MBP MAINTENANCE BYPASS BREAKER Howell NJ 07731 6 ANY DAMAGE TO SURROUNDING PROPERTIES INCLUDING SIDEWALKS,CURBS,TREES,AND STREET SHALL BE 6 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250 MCB MINI CIRCUIT BREAKERS NY Architect License#035290 REPAIRED SATISFACTORILY TO ORIGINAL CONDITIONS MCCB MOLDED CASE CIRCUIT BREAKERS 7. GROUNDING ELECTRODE CONDUCTOR(G.E,C)SHALL BE CONTINUOUS AND/OR IRREVERSIBLY SPLICED/WELDED MIB MAINTENANCE ISOLATION BREAKER 7 PERSONAL PROTECTIVE EQUIPMENT(PE)SHALL BE PROVIDED AS REQUIRED IN ACCORDANCE WITH NEC 70H AND MISC MISCELLANEOUS OSHA REQUIREMENTS 8 FLEXIBLE,FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS,LUGS,DEVICES,OR CONNECTORS THAT ARE MFG MANUFACTURER IDENTIFIED AND LISTED FOR SUCH USE PER NEC 690 31(F). MPPT MAXIMUM POWER POINT TRACKING MV MEDIUM VOLTAGE 9 THE UTILITY INTERACTIVE INVERTER SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION NEC NATIONAL ELECTRIC CODE AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THE STATE UNTIL THE ELECTRICAL NEMA NATIONAL ELECTRICAL MANUFACTURERS PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED ASSOCIATION GENERAL NOTES 10. DUE TO THE FACTS THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT,PV CONTRACTOR SHALL DISABLE THE ARRAY NESC NATIONAL ELECTRIC SAFETY CODE 1 THE GENERAL NOTES APPLY TO ALL OR UNDER THE CONTRACT REFER TO INDIVIDUAL DRAWINGS FOR ADDITIONAL DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING,OPEN CIRCUITING,OR COVERING THE ARRAY WITH OPAQUE COVERING NTS NOT TO SCALE OCPD OVERCURRENT PROTECTION DEVICE NOTES I1 ALL WIRES SHALL BE IDENTIFIED BY CIRCUITS IN ALL CABINETS,BOXES,WIRING TROUGHS,AND OTHER ENCLOSURES,AND AT ALL PCC POINT OF COMMON COUPLING 2 UNFORESEEN OBSTRUCTIONS ON THE ROOF MAY REQUIRE A CHANGE IN THE LAYOUT ANY CHANGES TO THE RACKING TERMINAL POINTS,I E,RECEPTACLES,MECHANICAL LUGS,COMPRESSION FITTINGS THE CIRCUIT DESIGNATIONS SHALL BE AS SHOWN PDU POWER DISTRIBUTION UNIT LAYOUT SHOULD BE REPORTED TO THE ENGINEER.CHANGES IN UP T06%OF THE MODULES SHOULD BE ANTICIPATED ON THE CONTRACT DRAWINGS OR AS DIRECTED BY THE SYSTEM DESIGN ENGINEER LABELS OR TAGS SHALL BE APPLIED TO WIRES SO PF POWER FACTOR CHANGES TO THE ARRAY LAYOUT SHOULD BE MADE AS TO NOT IMPACT THE NUMBER OF MODULES ON A COMBINER BOX OR THAT THEY WILL BE READILY VISIBLE POI POINT OF INTERCONNECTION INVERTER 12. BREAKERS SHALL BE 80%RATED UNLESS OTHERWISE SPECIFIED PRl PRIMARY PT POTENTIAL(VOLTAGE)TRANSFORMER Rev Date Description Initial 3 DRAWINGS ARE DIAGRAMS AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK FOLLOW DRAWINGS IN LAYING 13 FUSES FOR SWITCHES SHALL BE CURRENT-LIMITING TYPE WITH A MINIMUM INTERRUPTING CAPACITY OF 200,000 AMPERES RMS(UNLESS PV PHOTOVOLTAIC OUT OF WORK AND CHECK DRAWINGS OF OTHER TRADES TO VERIFY SPACE CONDITIONS PVC POLYVINYL CIILORIDE .00 12/2/20 Design MI OTHERWISE NOTED)AND OF THE CONTINUOUS CURRENT RATINGS AS INDICATED ON THE DRAWINGS ORAS RECOMMENDED BY THE MANUFACTURER PWR POWER .01 12/11/20 Panel Change MJ RCA RECYCLED CONCRETE AGGREGATE .02 12/14/20 Panel Change MJ RIBUPS RECTIFIER PHOTOVOLTAIC NOTES RMC RIGID METAL CONDUIT RS RAPID SHUTDOWN RTU ROOFTOP AIR HANDLING UNIT 1 ALL ASPECTS OF WORK RELATED TO THE SOLAR PHOTOVOLTAIC(PV)SYSTEM SHALL BE IN ACCORDANCE WITH ALL STATE AND LOCALTESTING SA SURGE ARRESTER CODES,UTILITY REQUIREMENTS,AND THE NEC,ESPECIALLY ARTICLE 690 SCH SCHEDULE 1680 Westview Drive, SEC SECONDARY Mattituck NY 11952 2 SOLAR PV MODULE FRAMES.SHALL BE BONDED TO RACKING RAIL OR BARE COPPER E G C PER THE MODULE MANUFACTURER'S LISTED 1. FINAL TEST AND INSPECTION SHALL BE HELD IN THE PRESENCE OF OWNER'S REPRESENTATIVES AND TO THEIR SATISFACTION SPD SURGE PROTECTION DEVICE INSTRUCTION SHEET TBD TO BE DETERMINED Owner,Orlowski Residence 2 MEGGER ALL.STRING WIRING,COMBINER BOX OUTPUT FEEDERS,AND AC FEEDERS SUBMIT RESULTS TO OWNER FOR REVIEW UL UNDERWRITER s LAB 3 SOLAR PV SYSTEMS SHALL BE GROUNDED IN ACCORDANCE WITH NEC 690 PART V.GROUNDING Solar Modules:(34)390W Modules 3 IV CURVE TRACES OF STRINGS SHALL BE GENERATED USING THE SOLMETRIC PV ANALYZER(OR EQUIVALENT DEVICE)AND UPS UNINTERRUPTED POWER SUPPLY 4 COMBINER BOXES,FUSING,WIRE SIZES,QUANTITIES AND CONDUIT SIZES BETWEEN SOLAR ARRAYS AND INVERTERS TO BE VERIFIED BYSUBMITTED TO OWNER FOR APPROVAL V VOLT Sola[Inverters:(1)SE 11400H-US Inv CONTRACTOR WITH SOLAR MODULE AND INVERTER MANUFACTURERS BEFORE INSTALLATION VA VOLT-AMPERE Vin INPUT VOLTAGE Solar System DC Size:13.2kW 5 ALL PV SOURCE CIRCUIT CONDUCTORS AND CONNECTORS SHALL BE SUPPORTED AND SECURED WITHOUT EXCESSIVE STRESS.NO WIRING VOC OPEN CIRCUIT VOLTAGE SHALL BE PERMITTED TO TOUCH THE ROOF SURFACE VOC Low MAXIMUM OPEN CIRCUIT VOLTAGE IN Solar System AC Size-114 kW 6 PV SOURCE CIRCUIT CONDUCTORS EXPOSED BETWEEN ARRAYS SHALL BE SECURED ON BOTH SIDES,AND BE PROTECTED FROM PHYSICAL LOWEST TEMPERATURE CONDITIONS Page Size.11"x 17" DAMAGE AND ABRASION,INCLUDING FROM EDGES OF RACKING,CHANNEL EDGES,WIRE TRAYS,ETC W WATT OUTPUT VOLTAGE 7 ANY CABLE TIES USED SHALL BE HEAT STABILIZED(-40C TO 105C),UV STABILIZED AND OUTDOOR RATED,SUITABLE AND DURABLE FOR WP WEATHERPROOF GENERAL NOTES THE ENVIRONMENT AND LIFE OF THE PV SYSTEM XFMR TRANSFORMER 8 WHERE EXPOSED TO SUNLIGHT,CONDUCTORS SHALL BE LISTED AND MARKED AS SUNLIGHT RESISTANT Z IMPEDANCE Scale:See Scales I Page 6 of 8 9 ALL EQUIPMENT GROUND CONDUCTORS SMALLER THAN AWG#6 SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY AN IDENTIFIED G-000.02_ RACEWAY OR CABLE ARMOR UNLESS INSTALLED WITHIN THE HOLLOW SPACES OF THE FRAMING MEMBERS OF BUILDINGS OR STRUCTURES AND WHERE NOT SUBJECT TO PHYSICAL DAMAGE I Drafting/Design Firm ®Electrical Characteristics 39ow 39SW 40OW ` `�•-e, '�a�j r . s;',: y' Nominal Oulput tPmpP) w t --390'" 399` - '40(i- • - _ PhRGD Volta9oatPmax(Vmpm) V 404 1406 409 -Power Optimizer' � "F ;- • Current at Pmax'(IMpp) _ A 97 9] 99 4�J ° GpgnonppR�vonaeacvoU_T -v - - �49= 4g,4 I For North America, - _ C q96 c 25 Broadway 9th Floor ` � P320/P340/P370/P400/P405/P505 *g•�`^'^^•-7 NY,NY 10004 OutpunTolamnon w — -G/,s - (833)747-3639 *' �y+.'p '• No of CallsBConnocaans„ �q' - - - 144 ho11-cellsin sgflgs/30ypasadiodof -- -• Maximum Series Fuse Rating- .-_.-__,-__-_,,.-_,-,..-.-- 20A --.--._...__..•___.._.. • �,^ - _-,I- • o Developer o�-M;:� Y�__ _ �"'y4,' += - Coll Typo ''_Y ✓w*� ='� Module Efficiency Is 194 19,6 199 _7 7em0aretura Coeffle ritofpiflpp r�N/C - - .i X041- . t /,s 1V Temperature Coefficient of Voc %/C ^--�-- — •031 ^- ----^• - - a �Y " "` BOW, SSI TempommroeoorR<romorlsc=-vx/e --. _. -_-_^_•_• --._''-oos ---- __ _�.- _ - 11a dear passal ®® �® Mechanical Characteristics ,I Dimensions m PRE kER50L, -RSQLUTIONS laminate- Glass 32 high transmission, l 5 _ ' - Premier Solar Solutions Half-Cell Monocrystalline Type see reve7se far EnpapS�la^'evA 7 Connor Ln H, SDP 9ack.n t woatliarproar elm prL7d rct soectf+ref D71s (9,auilwet en Deer Park,NY 11729 MDOHCII-04 - ` = (631)482-8303 CT39°HCO°04 Frame Anodized.1—Imim(Black or Sli CT3g5HCII.04 Power Output -.lunctton ac!_ IP67/IPGB - CT395HC00.04 CT400HCll-04 Warranty Output Cables 4mma 02AWG)PV Wim, CT40OHMO.04 Longthlam(472•) PROPERTY INFORMATION ,ep m Canrx,, is_ Polarized MC4 compatible _ a-•ee7 r•t O•' xlfrll.ILrz—llf�'•• PV power optimization at the module-level Wolgh! 230kg(5071bs) Features and Benefits Tax Map: 1000107000700019000 High Oualhy/High power 1 a ... /Specifically designed to work with SolarEdge /Fast Installation with a single bolt Operating Conditions /Neat generation maintenance with module- Inverters Roof 1 Azimuth:239° o Up to S90W black backsheet/40OW white bacWhegt a / Up to 25%more energy level monitoring e ULlisted(UL 1703) '• .,, NamfnalOperall19CollTamrp 45,%Yc • •`-"' Roof2 Azimuth•59° Opamting Tgmp raturo -40t 95•e /Superior efficiency(995%) /Meets NEC ion(AF I)andP Photovoltaic or arc volt(cult D pos,bva power output talemnce protectlan(Aste and Photovpltalc Rapid Maximum SyLtem voltage - 1,000V" •sx e-pon°°N` /from all types of module mismatch losses, shutdown System(PVR55) Panel Tilt: 180 - - from manufacturing tolerance to partial Limited Warrants Fire Performance Cla,g C/Typal shading /Module-level voltage shutdown for installer 0 25-year lines,power output warranty, Maximum Wlntl Loaa 50 lbs/ft-(2400 Pa) r 9 P firefighter safety Maximum snow Load 112 ros/n'(540o Pa) /Fleaihles stem design maximums ace and utilization 11 •sae-CMdInTa od'4 wvmd wenamr f or dNa94 Cg,tpI:crod o a PE Stamps/Signatures C UL w ,e- -A I(rY Adan!III!Ire aY1L1Nan•OgcNINe•iaNag•e1Pl.M.....L-T1eN•irsul.......PINa•xlolNO•TNIM solaredge com sola r usnn { �DiU,,Ir� "'INT :a N.,...N..n N.i..m PAmss Pwaw,Neao"'nese r�,r,m.r -1— �rw�,t«a�„e SAINT-GOBAIN avmwonre�mxdnmeuu,(�NavFmc9 Thomas Petersen Tom Petersen Architect,LLC ®Single Phase Inverter ®Power Optimizer 6 Country Lane p Howell NJ 07731 with H D-Wave Technology for North America For North America NY Architect License#035290 ~ SE3000H-US/SE380OH-US/SE50001-1-US/SE6000H-US/ P320/P340/P370/P400/P405/P505 Single Phase Inverter Z SE7600H-US -US/SE11400H-US I P370P340 1`400 (fopsos le (OUTPUT - - •' e W HD-lNave,Technology m ' WtvHKPw,e pNpul 300 1,0W 06v 500 ,�„ 160 1000 W00d20BV VA LlavrmanK Wncr Ou¢at 3000 38000 i.OV 500 WW @940V IH0@2e0y VA (INPUT for North America T 330QAV s9o9a oav mm®m6wm'" 0 3D r ,K PnM Vu"a9e Mu,Hom Mw SE3000H-US/SE380OH-US/SESOOOH-US/SE6000H=US/ _i IACD ps b°e Mm-Nan M x V NDP, a-4g a 6g 0-m 5-NN n.5-a/ M nor r-20-71 MxanunSaalC6cuaturem SE760OH-US/SE1000OH-US/SE1 140OH-US, m Kri aww+Nmn Ni 3.6o-60.5, n Inl 14 Nk Ma.mwn COva+nn0mpx Nnam O<bV4 Correa 9]S VS ns Atl4 'Cwre @2.W 16 71 iS 32 a2 415 A JJ [4krxy 945 6 O Yxa.r r)m-,.. + �Mx•,eum (Ova, 16 - 24 - 4A5 A Y rnakrx)' — 11 V1 A ,CID 1H J1ou1 I A Omro'�eU + , v, ;catty Lbn 1Ng Yawl�g Praeuwrt OUTPUT DURING OPERATION(POWEROPn141QERCONNECTED 70 OPERATING SOLAREDGE INVERTER) �o "- c• , c=C=I. .ma.nn� Is � edw=-•FID__ d � w.,m,aaavxw¢mp m I as I car 1 1 (INPUT I OU1P(T DURING STANDBY(POWER OPOMMR DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE MAw,vn DCPawerON°y ,450 59°0 ]T50 9300 1100 1550 1,650 W !INVERTFAO D 91 ,Ma.e'um O<Power@mBVI SW 71501s5m W f TrWsla,ma k,,U,e rxd w, r- °�"P"";"0°°' "af w` Rev Date Description In1t)al STANDARD COMPLIANCE 4M „� rcceans Gmsaac6v�m6"zec6xaa6) .00 12/2/20 Design MJ r __ •�� _ - ,Nw..vine xw saM9e 300 I 4m Mxse� RCEama(am6,c IRnn ���� MamNmkpnCurtmtR2aM"> as ass Gs ws 1 m n Sas Adc l4wycw5�xx .01 12/11/20 Panel Change MJ 9 1 us I z] Aa RobI e I 02 12/14/20 Panel Change MJ ``sem hey„�._',.,,.,"".+ -}- •-�Pµ .-. .,�pd Ma.inputkiart GrttJ10u1ent 45 Adc 1 INSTALLATION SPECIFICATIONS •' e. ®I Rlwerse-Palany PrOaNan Yes Mavau,,xn A'b,ed S,nem 1 , G JM iJLLM1 lsddl,an Rledbn 6W.u5env�nnY � Nk lfe' ! -0 i y Mawumvnerlet ElkkKy 59 992 ss COmpGabinxrrert Aasear s6eNNNNa1l11%we1I" 1I _ 1 � ` _ aua.wp(w,L,w u4xs3ans/s,.6xu mm/N , ^- i 'C(cw nLLV(P[rem 99 mas3,vs/ 69.49.z/ 99aR,591 93@2a0V 51,6,(3 Sl,4n,ts St,ea,23 4n5PmBV I ]Sit/V I845/19 W,/23 /0 e 01 ale d°tl' •”` e; p Nryhaim2 Ao'.ror Can.umpUon <25 W In Cemt<M1680 Westview Drive, Most •.w+w»=-. ..a.,�,.,•4.-„.�,.�,,.>a,..,..•+-•a- (ADDITIONAL FEATURES- wee m x16/0.0 m/h S Pm.a(a mN a bmr Mattituck6 NY 11952 - ' _ _ __ - _ xa�Cieda cam wig eD2g owovr wanuretm9m a9/zas u/u m/n _ ., _ - _ 6xporo.e s0-•SS/r0•+ffi T/T Rd 9Nt6awn-rv(cmxl na4 A,Ap,ppi,Cp�pSn,s4mmr OpanKGM pis[onr,en p,oame,x IMe/NtwrP Owner Orlowski Residence +mit 69alz Optimized installation with HD-Wave technology ISTANDARD COMPLIANCE a.- g4a.n N��a wmm- r a P we.+°,=.n.e,.•� N Solar Modules:(34)390W Modules Sak6r IriRat u(n,l5n UI699a CSAC132 Carpdan 130 M<ddybTlLMUi a �N°eelmurWw•4mmmv.w'mv Gad Cu.xrasr151aMads aED547 rwN24 Rubk M° `� .v.amr6P•,rkaa*•n3n+raP / Specifically designed to work mth /Extremelysmall _ I a,.am,.N,+•tic/•m.w+m•.ay.swnas.oweay,cw.z.w�.••a.wvsomeNmc,.o.ama. Emmarn fccP4d.O.a I Solar Inverters:(1)SE 11400H-US Inv Power opbmrzers •• (INSTALLATION SPECIFICATIONS _ - pp�p,p•p3� / Record-breaking efficiency /Built-in module•leve,l monitoring ,KowwKwvasva/AwnRmee I Ma.6mmi/w-BAwc t MRdrm,mn4rA',vc Muummsmgu+9°i we-° 4 u as Solar System DC Size-13 2kW aNrya Crn0J15w/eg54vgf/ IMa,mun/121,1 /M 6A1lG 1'rpWm,mJl3saary/NGAwc 01cree 6So B H y laz System AC Size:l 1 4 kW M5 51491m9A / Fixed voltage inverter for longer strings I Outdoor and indoor installation ,o+nrcm,wnSe+aM5waln m/, a 2s s� Pag eSize.II"X1711 aMW4)1 n],iab,6a/450x3Rl,ria 213aY16v]3/540x3m,teS L Swa100w5, ICmum Pcv PeSah9 SE]EOall$-SDN9o- 5150 tg0a• RISA^ W / Integrated arc fault protection and rapid shutdown for /Optional Revenue grade data,ANSI C1220un Awea4vmnyerysw4m uno .xs 2SI/n4 zaznt9 sit Sae/n5 tip' P,vaasv paomnemtmPa +s SPEC SHEETS NEC 2014 and 2017,per article 69011 and 69012 Class 05(05%accuracy) 'O"""0 eaa�re N4wN(dlrtela0 M�'aw`m aa, w„��awxuwMsn.vwsasvrv,a� / UL1741 SA certified,for CPUC Rule 21 grid Optratme]emµvYue Ran[ -13m•fe0/ZSb.60`(�.PF/-4p'C aDamF T/r., a `4N°$ayssm 'm"�1PK;,,a";m:,,?,an,,.,.c,ra, w c„e,roxN„o.,.,m eompbance mecca Rz-m Ntauax eAom.wun 5i'eYSw4rhl `�`]Nm v9]°Oo6'0r,x�e.i4weesm.. v.9.mnn>.�m,rm,.�o:t.-Nroe.vP.awvormp.roam � w.ram,...r<d,.,...,.,Pewmt . ^kra,wm9mWN.¢ue,Naeu vnx+5Na1a9caxro3 •�,;,«>A bNMsgN� 9 Scale:See Scales I Page 7 of 8 e solaredgecom solar nammw.Aa,..md.��,._.. .,.•, .�N.wNa�aw ” RoH5 RoHS G-001 .02