Loading...
HomeMy WebLinkAbout46503-Z �o�sOfFUI Town of Southold 8/18/2021 y P.O.Box 1179 o • 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 03380 Date: 8/18/2021 THIS CERTIFIES that the building HVAC Location of Property: 1500 Marratooka Ln.,Mattituck SCTM#: 473889 Sec/Block/Lot: 115.-3-19 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/21/2021 pursuant to which Building Permit No. 46503 dated 6/28/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: HVAC installed to existing single family dwelling as aapplied for. The certificate is issued to Cuddy,Charles&Elaine of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46503 7/28/2021 PLUMBERS CERTIFICATION DATED Authorized Signature �SUFFoi,r�o TOWN OF SOUTHOLD ao aye BUILDING DEPARTMENT N z TOWN CLERK'S OFFICE "o • SOUTHOLD, NY y�ol �ao�;s BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46503 Date: 6/28/2021 Permission is hereby granted to: Cuddy, Charles PO BOX 1208 Mattituck, NY 11952 To: Install new HVAC to existing single family dwelling as applied for. At premises located at: 1500 Marratooka Ln., Mattituck SCTM #473889 Sec/Block/Lot# 115.-3-19 Pursuant to application dated 6/21/2021 and approved by the Building Inspector. To expire on 12128/2022. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO-ADDITION TO DWELLING $50.00 Total: $250.00 Building Inspector ®�'aoF soU�y®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 ® �Q Sean.devlinl'a)-town.Southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To. Charles Cuddy Address: 1500 Marratooka Ln city:Mattituck st: NY zip: 11952 Building Permit#: 46503 section: 115 Block: 3 Lot: 19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: AS BUILT License No: SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic X Garage INVENTORY Service 1 ph Heat Duplec Recpt 2 Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 2 Switches 2 4'LED Exit Fixtures Pump Other Equipment: Notes: " AS BUILT NO VISUAL DEFECTS " Two New AC's Inspector Signature: Date: July 28, 2021 S Devlin-Cert Electrical Compliance Form 60� ho�apF SOUTyO� # # TOWN OF SOUTHOLD.BUILDING DEPT. °`�courm 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: �-�/ - 1V� hcm A,, bee(m- J vii t0 DATE INSPECTOR �o��,oF souryo6 Ll # # TOWN OF.SOUTHOLD BUILDING DEPT. ycourm '� 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [A ]_ INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION rl PRE C/O REMARKS: _AJ- -s�iNl� l A 11VLffj,_6 V DATE INSPECTOR FIELD INSPECTION REPORT DATE FOCENDATION IST -------------;---------.- --------- ci FOUNDATION(2ND) C) t A . ROUGH FRAMING I& PLUMBING H INSL-, ION PER N.Y. H STATE IENERCY CODE • �. �IN'AL { -a$r z X i �o�OSUFFO(�coGy TOWN OF SOUTHOLD—BUILDING DEPARTMENT y Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 https://www.southoldtownny.gov Date Received APPLICATION FOR BUILDING PERMIT For Office Use Only PERMIT NO. �v Building Inspector: JUN 2 1 2021 -Applications and forms must be filled`out in their entirety.Incomplete a lications-will'�not be,acce;ted. Where,th-e p: licant is not the owner _an Y� `1 r 1PT pP P PP , . . Owner's Authorization form-(Page'2i,shall be complefed. Date:June 3, 2021 m OWN ERS)-OF=PROPERTY: - - - Name:Charles R. Cuddy_ SCTM#1000- l I5 — 3 — Project Address:1500 Marratooka Lane, Mattituck, New York 11952 Phone#:631-298-8452 @P Email:charlescudd Y_ o tonline.net Mailing Address:PO BOX 1208, Mattituck, New York 11952 CONTACT PERSON: Name:Charles R. Cuddy Mailing Address:PO BOX 1208, Mattituck, New York 11952 Phone#_6310-298-8452 Email:charlescuddy_@Optonline.net "DESIGN'P111 SIONAI INFORMATION: - ~ Name:Burt's Reliable Inc. Mailing Address:1515 Youngs Avenue, Southold, New York 11971 Phone#:631-602-3134 Email: CONTRACTOR iWO_RMATION Name: Mailing Address: Phone#: Email: lJ8CRIPTION'6F PROPOSED CONSTRUCTION_ ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: E Other Installation of central air-conditioning system $20,750.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes RNo 1 PROPERTY INFORMATIoN'w. x±_ e of property: Intended use perty: Existing use of pro �. _ w esi_entia _._.Residential_ Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? ❑Yes ®No IF YES, PROVIDE A COPY. L Check Boz After Reading: The owner/contractor/design"professional is f4sponsidlefor all_&ainage and storm water issues as provided by chapter 236 of the Town,Code.APPLICATION IS HEREBY MADE to'the Buildirig"Department fol the issuance of a Building Permit pursuant tothe Building Zorie `Ordinance of the Town of Southold,Suffolk,'Cotirity;�NdW York and othee applicable Laws,QiAinances or Regulations,for the construction of buildings, add ition`s;alterations or for removal or demolition a`s_lieeeiri=descfi6ed.The apgllcarit agrees to corn`ply with all applicable'laws;ordinances,lwilding code; housing code and regulations and'to,admit authorized inspectors on-premises and in.building(s)for,,necessary_in"spections.False'statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law: Application Submitted By(print name):Charles R. Cuddy ❑Authorized Agent BOwner Signature of Applicant v_ l _ Date: fQ o � STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Charles R. Cuddy being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)heisthe Owner (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 10,day of 20 �t Notary Public IWONA KODYM PROPERTY OWNER AUTHORIZATION Notary Public, State of New York (Where the applicant is not the owner) No. 01K06088386 Qualified in Suffolk County Commission Expires March 3, 20 LS I, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 �O�Og1�PE0(,��oGy BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD N = Town Hall Annex- 54375 Main Road - PO Box 1179 o e Southold, New York 11971-0959 'y O� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerra-southoldtownny.aov — seand(a_southoldtownny.aov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Informatiop Required) Date: ZI? Company Name: Name: License No.: email: Phone No: ❑I request an email copy of Certificate of Compliance Address.: JOB SITE INFORMATION (All Information Required) Name: Address: p Cross Street: Phone No.: Bldg.Permit#: ® email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) G Check All That Apply: Is job ready for inspection?: ❑YES ❑NO ❑Rough In ❑Final Do you need a Temp Certificate?: ❑YES ❑NO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 ❑2 ❑H Frame❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx fFOAll BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD s Town Hall Annex- 54375 Main Road - PO Box 1179 �. Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(cr� outholdtownny.gov seand(a).southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: ' J Company Name: � Name: License No.: email: Phone No: 01 request an email copy of Certificate of Compliance Address.: r JOB SITE INFORMATION (All Information Required) Name: G' Address: Cross Street: Phone No.: Bldg.Permit#: C9 email: Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Check All That Apply: Is job ready for inspection?: 2<ES ❑NO ❑Rough In ❑Final Do you need a Temp Certificate?: ❑YES LSO Issued On Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A # Meters Old Meter# ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead # Underground Laterals ❑1 02 ❑H Frame ❑Pole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx Client#: 33346 BURTRE ACORD. CERTIFICATE OF LIABILITY INSURANCE DATD/YYYY) 6/003/203/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: 320 South Service Road E-MAIL Bradley&Parker,Inc.C/L PHONE Bradley-&Parker,Inc.C/L FAX ac No Et):631-981-7600 A/C No): 16319817681 Melville,NY 11747 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# 631 981-7600 INSURER A;Houston Specialty Insurance 12936 INSURED INSURER B;State Insurance Fund 36102 Bums Reliable Inc PO Box 696 INSURER C:Imperium Insurance Company 35408 _ INSURER 6: Southold,NY 11971 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE ADDL SUBR POLICY EFF :POLICY EXP INSR WVD POLICY NUMBER MMIDD MM/DD LIMITS A X COMMERCIAL GENERAL LIABILITY X X ECAP2HSGL00012900 7/01/2020 07/01/2021 EACH OCCURRENCE $1 000 000 DA�uIAGE TO RENTED CLAIMS-MADE OCCUR PREMISES Ea occurrence $1 OO OOO MED EXP(Any one person) s5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $2,000,000 X POLICY JET LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER, $ C AUTOMOBILE LIABILITY X X ECAP211CCA00012900 7/01/2Ea .020 07/01/2021 COMBINED SINGLE LIMIT accident 1,000,000 X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY pAMAGE X AUTOS ONLY X AUTOS ONLY Per ac.Q $ A X UMBRELLA LIAB X OCCUR X X ECAP2HSCX00012900 7/01/2020 07/01/2021 EACH OCCURRENCE s4,000,000 EXCESS LIAR CLAIMS-MADE AGGREGATE s4,000,000 RETENTION$O DED X RE $ B WORKERS COMPENSATION24528879 5/01/2021 05/01/202 X PER OTH- AND EMPLOYERS'LIABILITYIER ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E L EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? � N/A (Mandatory in NH) E L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E L.DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) EVIDENCE CERTIFICATE HOLDER CANCELLATION MR.CHARLES CUDDY SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION, DATE THEREOF, NOTICE WILL BE DELIVERED IN 1500 MARATOOKA LANE ACCORDANCE WITH THE POLICY PROVISIONS. Mattituck,NY 11952 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S668087/M664719 SRM CHARLES R.CUDDY ATTORNEY AT LAW 445 GRIFFING AVENUE RIVERHEAD,NEW YORK Mailing Address: TEL: (631)369-8200 P.O.Box 1547 June 11, 2021 FAX. (631)369-9080 Riverhead,NY 11901 E-mail:charlescuddy@optonline.net Town of Southold Building Department Southold Town Hall Annex 54395 Main Road Southold, New York 11971 Attention: Michael Verity, Chief Building Inspector RE : 1500 Marratooka Lane, Mattituck, New York Dear Mr. Verity: In connection with the air conditioning of my home at 1500 Marratooka Lane, Mattituck, New York enclosed is the following: 1 . Application for Building Permit . 2 . Surveys marked with the location of the two condensers . 3 . Rheem Condenser brochure together with the Certificate of Product Ratings . 4 . Certificate of Liability Insurance including Workers Compensation and Employer' s Liability. 5 . Check payable to the Town of Southold. I would appreciate your providing me with a building permit and advise as to when inspections are to take place . Very truly yours, CWOX'I Charles R. Cuddy CRC :dmc Enclosures S %,ertificate AHRI Certified Reference Number:201211333 Date.06-09-2021 Model Status:Active Old AHRI Reference Number:7508908 AHRI Type:RCU-A-CB(Split System:Air-Cooled Condensing Unit,Coil with Blower) Outdoor Unit Brand Name:RHEEM Outdoor Unit Model Number (Condenser or Single Package):RA1336AJ1 Indoor Unit Model Number(Evaporator and/or Air Handler):RH1 T3617STAN Region: North(AK,CO,CT,ID,IL,IA,IN,KS,MA,ME,MI,MN,MO,MT,ND,NE,NH,NJ,NY,OH,OR,PA,RI,SD,UT,VT, WA,WV,VVI,WY,U.S.Territories) Region Note: Central air conditioners manufactured prior to January 1,2015 are eligible to be installed in all regions until June 30,2016.Beginning July 1,2016 central air conditioners can only be installed in region(s)for which they meet the regional efficiency requirement. S;,r„,�'',�s' ,.�'jt.;•,�v,NA�f;�w�t £.F"d�."��-=7:t«aYPf %X, .d*f'Mn.•=%R;,'.�f,.l."`jyY.ko� :`?k"`�'J h' `r'k ""''�'.T,•f r"-:_ Pyn•<a .5.6< - _ "'�" ^..,"< _ ?s�`}*3,.�y';✓^x- - ''z - ^{,,w.': ,yam`,-, �,, '+'fi:'`.-=rp•tµe,< �'TMfi' -'",�a,"=;s'"��.�s'u?j�.'1,:,7i`5;i�< ,.? .;a`^'�.-„`a•::n «y� ';"r . �= a:.� �_ s:.. The manufacturer_ofthjs HEEiUj` roduct;is`res onsl_ble •, °`' "W”"`""" `° ` s .R ,p p for:the.ratirig of this.system,co�7tiinapon r *J wi >x"�_"t��;.ds"s,zd:='- RR'"'a*'=:;-''=:-' `•�r,•` »g 2''d«*,'i'i>.'"' -;3":`' °ri"`? a',,.=':ns�+._.�r �`ix a;,-<'w.,��- - "-;1^z7 K,."',i t.,`-''�'° .,,••rr, _ ln. 3s.,w,,.xi.:_«".=:wrw„yezixEt�'a__ fia5."�ti'�r»,.:,„P7+�ir'�}.L�n >S'._.cw.4,,•,34 - ,ty�urti -;j '�s,'. ,s "'`_• ,. ,,,4.ar; ° ;c ",« F,» '. - +, .i_� .,�,°per.,,.�?.„,§ «:��f^,'rxr'�" "-"°' a,,.- *rr fa' u�.^_,°.,s•. 4"., �c^d.3`} -v "� „x+.^'; :s 4 '.• _ �&�., WV Rated as folrov s i accoSda ce '"th,�he latest edltlonfof�A-'R1112,O/2'4:"Q ith�A�dd�ntlhlri�l�t?erfo maty ejRatin �ofUhka"ry r-C dttjontng &Air:S u�ce'3 ea Pum ui ent and sub ec oto rating accura ar. = i7v p q pri) j t g cy by AFiRl=sponsored;:independent�'t'ird-ppiiy,testings,'RA < w3 iia° . ° _. w ti s . r, Cooling`~°.Gap eity1 Z-j'==SI 1 to or I h Stage 95,f)Wbtuh 342 p= 1 SEER€r 14=0'0` >:=i:'.'. at.b"-Y^:y,: a-,r.' _.,�.��..� ,„x..,��::, :at;".°"a`n��_ a,_r�Ai' xh-,�`� se�"�-P��`- - •�^ _y€.� "+.r5;.rr"'T'F�t3,,,N.-f„ '�+..T:,��„`. !w,'�`°'� _ r=.-,. ,�,ti v"„ ..�,-" ,�;3. r r a.. - ypt•�-,"��"_'�'" �-�. ,�~� 7, .3;�e„': - �;r_. '.moi <4 --4 =«,;`,�`+.-` a k�d_'s r. a-Y�£Gr".T`y,,�_.-,g” r�a«. .w"�,��:-�y.�.�;;�'s, a ..•.e�:.;.;,-;.��,,:�;%``:°*,vas't�.�:r=;4:�' �r�°^�.xr`�=;'._.-_ n',+'?•y.'':.^ °'•, ;; EER-'(A2)r-Slagle odNigh Sfaf=t(95F ,;1 4 app. ,+ r. - .' `'3 . )= a •; '�'°' ` ' $. r'. v mri �. 'e.f .�`." �i;�i" _ i, r. `i.E}_- Tye="i<'.« _;¥' •a.x" R�f »* �A,t<,•.#� --_='' ic*,.gt`,,^t.,s.--''�yS u;,.. .,�Y�at.<'a��sv¢'"vk ,- ,..�A,,�.., .ht;„' yG•y, ;..`: �-•. -' 'a,, �x-,7,..,}•- -- z'�y�,�m--.. .a....r,�;.�,:._�«�;;.�a.,-�.�»:°�.,�..s3..t-�.�:�.�s. 'as,:car �, Paa•">.,,�.a� �.�-.r .�._..� � '��`r,°.��`?�?r ' � ate..•--s,..,.-^�C''"w .'*':� '�,�. .�`:`3il�.-«.....,..:m:::�s�:. -=:.�aa:�::r,-:`7a.. "a ,•" '_i' ,-". ""N °�,.a�";„, �° � ;was , r•v" � r"� wa � _ gt`<.. ,aa,� k.. rA,z,. �;�&c«v �"ks- �,�?' �''�.rr �•�`�`"• "��``,°�?a��=`�, ��.� d„u � .;�: °,id F-r; »net^, ��,°k�'°:' ,'�`�':rrkM,,,3:'+' .tax ;� s�(';#s�-, e4P s X;='•`�', t`; :}� ��± 7 r �' rn v 1s`��k7'�;ti.:.� ,�y t+ � �r,�^x• *"11N•,,?r: a;,�r,e''� .w.>;fav;'-,._';ti.;�W�'.1-`�� ,._,�'.�.�:�.�^-�, ,.�,�"�,x„a`�7..,� ;"x �.,�."`�w.«,� , _ .a., ,��,,m „tya.,,>, ra:`�."a�^•,ph«;•,���'..=t't�;�as=„i.* ,,h. .- t w r-fr:.C�. u>i _ �'3 E/x'�_ iat``x'�.f'=."•w _ _ ,a.,�,`: _.. .. t., _ .f b..�., J"� t"Active"Model Status are those that an AHRi Certification Program Panccipant is currently producing AND selling or offering for sale,OR new models that are being marketed but are not yet being produced:Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an mvoluntary re-rate. The new published rating is shown along with the previous(Le WAS)rahng. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.shridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal find confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; f entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrldirectory.org,click on"Verify Certificate”link we make life better"' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. -° a µ,r{°'<•;'y''•^_ "' ° `"s.K e,r;;' 1326773780251 13469^"• ©2021 Air-Conditioning Heating and Refrigeration Institute IFICATE`'`NO. 69 400 Ostrander Avenue, Riverhead, New York 11401 £� tel. 681.727.2303 fax. 631.727.0144 flea admin®youngengineering.com �a E< M4 �01m� gg-'n Howard K Young, Land Surveyor Thomas 0. YVolpert, Professional Engineer Douglas E. Adams, Professional Engineer w Robert 0. Tast, Architect o w � E Robert 5trom5ki, Architect SUNSET AVENUE § . W�FW~ MCA S <0,m (FW 14)Jr W= / V)41z % Ro Tz V1 �F�o /(FW 13) now � m �o < <a 11,50. Elaine EfOrmerly =b ud y ;=In, v� v ^� 11 )�`63p• ip; ao7< Q� z yJ0 , (FW,0) F r Rip zu 275.29' ! c) LO �v (FW 8) OHO Cp D _i N j N • Al j,k/3 o 396.00, 1n \` SITE DATA Q FW A. �J / ___ N<zo b o cFW a�- __ S5 Q 24,• -------------------- -------- AREA = ACRES --------------- 1 .283 A VLGRA d DR'v,-WAY h Z 2'V/ /(FW 4) C9 O z f3(FW 3) p Qf(FW 2) 9(FW 1) i GRASS e- �_ w00p t QZmW LO O -s aecc/A73 -URB N F- SURVEYOR'S CERTIFICATION W� Nk FeNCe / 78 02 9 1p4. `_ Q n° / WOOD FENCE p � • THIS MAP WAS PREPARED UTILIZING SURVEYS MADE BY US bg9a Robinw or f Mo N FOR CHARLES R. CUDDY & ELAINE E. CUDDY IN SEPTEMBER, 1991. E °rmerl y l >.o / 94.87' CP,AbE�D Wickhl Rll�yyAY � - °m / n O w Or / SPUTFEN > C t d 4 l Bret f rm erl y / // 130.8 5 j / Susan edges / 4 6.31' c l an HCN edges Ronow °r for lt'rlrat�c,� , �� 'o bert S. B merly /r. .'':�` = o arker t+ \ Y ''�b / Anthony now or f HOWARD W. YOUNG, N.Y.S. L.S. NO. 45893 l / C °rm erl y `\ `o L / Nicholas CciaopPO ._.- / aC/a0 PP o / N M SURVEY FOR CHARLES R. CUDDY & ELAINE E. CUDDY I�-;E ERE At Mattituck, Town of Southold G12 Mz Suffolk County, New York Id =S WE 0 County Tax Map District 1000 Section 115 Block 03 Lot 19 BOUNDARY SURVEY O ADDED CONDENSERS JUNE 18, 2021 JAN. 4, 2001 gNs UPDATE SURVEY & LOCATE FLAGGED WETLANDS DEC. 13, 2000 �� MAP PREPARED JUL. 31, 2000 SCALE 1" = 40' 1 �6G = MONUMENT SET MONUMENT FOUND D= STAKE SET A= STAKE FOUND ® = PIPE o(FW 2) = NUMBERED LATH JOB NO. 91-0847 1 OF 1 �b1 DWG. 910847-20210204 5 e"ie-oc APPROVED AS NOTED DATE: B.P.# b,5-a-192 OCCUPANCY OR FEE: 0•cv BY: NOTIFY BUILDING DEPARTNlc-NT AT USE IS UNLAWFUL 765-1802 8 AM TO 4 PM FUR THE WITHOUT CERTIFICATE FOLLOWING INSPECTIONS 1. FOUNDATION - TWO REQUIRED F OCCUPANCY FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ELWMWAL DMEMON REQUIRED C(3MpL.Y WITH ALL CODES 0 E TOWN CODES NEIN YORK ST AS REQUIRED AND CONDITIONS OF SOUT'HOLD TOWN ZBA SOUTHOLD TOWN PLANNING BOARD SOUTHOLD TOWN TRUSTEES V.S.DEC � | �no�m�� -a | RAI xSeries _~ ~�-_ ��nn� . ux ���� ������ ��Series ��. Conditioners��� "������U~Koners RA13 Series Efficiencies UptO158EER/13EER Nominal Sizes 11/2tO5Ton [5.28 to 17.8NWj Cooling Capacities 17OtO6O.5kBTU [5.7tO17.7kW] WE ' ~ ` "Proper shdng and Installation of equipment Is critical to achieve optimal --------------- performance.Split system air conditioners and heat pumps must be matched with appropriate call components to meet Energy Star. Ask your Contractor for details or visit wwwonergystargov." ° louver ° opaning- .° Powder,coatFaint system-forulong lasting professional finish ° External gauge port access-al|ows easy connection of ° Scroll compressor-uses 70Y6fewer moving parts for higher 'mw/'luoa'gauge ports effioionny'ondincreased reliability ° Single-row condenser coil-makes unit lighter undoUuwm ° Modern cabinet aesthetics-increased curb appeal with viou' thorough coil cleaning tomaintain"out nfthe box" ,ally appealing design performance ° Curved louver panels provide ultimate coil protection, ° 356fewer cabinet fasteners and fastener-free base-allow furh��araoceootnintarnu|cnmpono��ondhaoo|o-hao enhance cabinet stmmg¢h.and increased cabinet hgidity ° Octimizodfanohfico-optimizenoirDmwondmdunnounit panel removal sound ° Service trays-hold fasteners orcaps during service.o�|o ° Rust resistant.screws ° ORcndo-pmvideutonhnioo|infonnagionondemondfor *o�gornomioanaUa np�y��o�ing ° P|uoOne`mExpanded Valve Space-3^-4^-5^service valve ° Fan motor harness with extra long wires allows unit top tnba space-provides uminimum working area of27'oquare removed without disconnecting fan wire. inches for easier access ° P|unOnermTriple Service Access-15''wide,industry lead- ing corner service access-makes repairs easier and faster. eodingoomoronpvioeuooaua-muhoon*puhseouiorondfostor. The two fastener removable corner allows optimal access tu internal unit components. Individual louver panels come out once fastener ioremoved,for faster coil cleaning and easier cabinet reassembly r = e Air ITable of Contents RAI 3 Series TABLE OF CONTENTS StandardFeature......................................................................................................3 AvailableSKUs ........................................................................................................3 Features&Benefits ..............................................................................................4-5 Model Number Identification....................................................................................6 General Data/Electrical Data....................................................................................7 Accessories ............................................................................................................8 WeightedSound Power............................................................................................8 ,"nit Dimensions........................................................................................................9 Clearances..............................................................................................................10 WiringDiagrams ....................................................................................................11 ApplicationGuidelines............................................................................................11 Refrigerant Line Size Information......................................................................12-15 PerformanceData..................................................................................................16 GuideSpecifications ..............................................................................................17 LimitedWarranty....................................................................................................18 'INTEGRATE. . .- Air Standard Feature/Available SKUs 0 RA13 Series Standard Feature Table STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-41 Oa Refrigerant J J J J J J J Maximum SEER 14.5 14.0 15.0 15.0 14.0 135 13.5 Maximum EER 12.5 120 13.0 13.0 12.0 11.5 11.5 Scroll Compressor J J ✓ J J J J Field Installed Filter Drier ✓ J J J ✓ J ✓ Front Seating Service Valves J J J J J J J Internal Pressure Relief Valve J J J J J J J Internal Thermal Overload J J J J J J J Lang Line capability J J J J J J J Low Ambient capability with Kit J J ✓ J J J J 3-4-5 Expanded Valve Space J J J J J J J Composite Basepan J J J J J J J 2 Screw Control Box Access J J J J ✓ J J 15°Access to Internal Components ✓ J J J J J J Quick release louver panel design J J J J ✓ J J No fasteners to remove along bottom J J ✓ J ✓ J J Optimized Venturi Airflow J J ✓ J J J J Single row condenser coil J J J J J J J Powder coated paint J J J J J J J Rust resistant screws J J J J J J J OR code ✓ J J J J J J External gauge ports J J vr J J J J Service trays ✓ J J J ✓ ✓ J J=Standard Available SKUs Available Models Description RA1318AJl NA Classic®Series 11/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1318AJI NB Classic®Series 11/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1324BJl NA Classic®Series 2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1324BJl NB Classic®Series 2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1330AJ1 NA Classic®Series 21/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1330AJl NB Classic®Series 21/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336AClNB Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/3/60 RA1336ADl NB Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1336AJI NA Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1336AJ1 NB Classic®Series 3 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1342AC1NB Classic®Series 3 1/2 ton 13 SEER Single-Stage Air Conditioner-208/230/3/60 RA1342ADl NB Classic®Series 3 1/2 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1342AJI NA Classic®Series 3 1/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1342AJl NB Class/c®Series 31/2 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348AClNB Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/3/60 RA1348ADl NB Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1348AJl NA Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1348AJl NB Classic®Series 4 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1360AGl NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/3/60 RA1360ADI NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-460/3/60 RA1360AJl NA Class/c®Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 RA1360AJl NB Classic®Series 5 ton 13 SEER Single-Stage Air Conditioner-208/230/1/60 • • ' r r Air Features&Benefits DI RA13 Series Introduction to RA13 Air Conditioner The RA13 is our 13 SEER air conditioner and is part of the ;rt sf 7 yT. au.rw`:CT.1 . s; Rheem air conditioner product line that extends from 13 to 20 � �_�;.�� �i,�•�rr't� � d _• _-_�- �'o ',•:,,; ,y SEER.This highly featured and reliable air conditioner is designed for ears of reliable,efficient operation when matched 9 Y P '`. with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. Our unique composite base( 1❑)reduces sound emission,elimi- nates rattles,significantly reduces fasteners,eliminates corro- If in the rare event,greater access is needed to internal compo- sion and has integrated brass compressor attachment inserts nents,such as the compressor,the entire corner of the unit can (0). Furthermore it has incorporated into the design,water be removed along with the top cover assembly to have unprece- management features, means for hand placement(a])for unit dented access to interior of the unit(14). Extra wire length is maneuvering,screw trays(®)and inserts for lifting off unit incorporated into each outdoor fan and compressor so top pad. T5-1) cover and control panel can be positioned next to the unit.With minimal effort the plug can be removed from the compressor 1❑ =' .--- =° and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit Outdoor coil heights range from as short as 22"to 28",aiding ' access to the compressor. Disassembly to this degree and com- MEMO ' i plete reassembly only takes a first time service technician less ti z =- `- M than 10 minutes.(15) 4 4 © 3❑ d w Service Valves(©)are rigidly mounted in the composite base with 3" between suction and discharge valves 4" clearance below service valves and a minimum of 5" above the service valves,creating industry leading installation ease.The minimum10 27 square-inches around the service valves allows ample room to remove service valve Schrader prior to brazing, plenty of clear- "�.n 14 '' A =����° 15 P 9 Y Q -� ance for easy brazing of the suction and discharge lines to ser- vice valve outlets,easy access and hookup of low loss refriger- All units utilize strong formed louver panels which provide indus- ant gauges(❑i ),and access to the service valve caps for try leading coil protection. Louver removal for coil cleaning is opening.For applications with long-line lengths up to 250 feet accomplished by removing one screw and lifting the panel out of total equivalent length,up to 200 feet condenser above evapora- the composite base pan.(E)All RA13 units utilize single row tor,or up to 80 feet evaporator above condenser,the long-line coils(is)making cleaning easy and complete,restoring the instructions in the installation manual should be followed. performance of the air conditioner back to out of the box perfor- mance levels year after year. Osl• .�"�,s, ;ice- .� <� w '�a.,s' Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover,revealing the The outdoor fan motor has sleeve bearings and is inherently industry's largest 15"wide and 14"tall control area(®).With all protected.The motor is totally enclosed for maximum protection this room in the control area the high voltage electrical whip(❑s ) from weather,dust and corrosion.Access to the outdoor fan is can easily be inserted through the right size opening in the bot- made by removing four fasteners from the fan grille.The outdoor tom of the control area. Routing it leads directly to contractor fan can be removed from the fan grille by removing 4 fasteners lugs for connection.The low voltage control wires(io)are easily in the rare case outdoor fan motor fails. connected to units low voltage wiring.If contactor or capacitor (11)needs to be replaced there is more than adequate space to Each cabinet has optimized composite(is)fan orifice assuring make the repair.Furthermore,if high pressure and low pressure efficient and quiet airflow. model was not purchased but is desired to be installed in the field,the service window(ii)can be removed by removing two screws,to access the high and low side Schrader fittings for easy � � r« is field installation.The entire corner can be removed providing '' M3 ultimate access to install the high and low pressure switch.(13) ` Features&Benefits Air I RA13 Series The entire cabinet has powder post paint(20)achieving 1000 Optional Accessories hour salt spray rating,allowing the cabinet to retain its aesthetics (Refer to accessory chart for model#) throughout its life. Compressor Crankcase Heater 24 Protects against refrigerant migration that can occur during low 20 ambient operation 23 Compressor Sound Cover •Reinforced vinyl compressor cover containing a 11/2 inch thick batt of fiberglass insulation 22 21 •Open edges are sealed with a one-inch wide hook and loop fastening tape Scroll compressors with standard internal pressure relief and Compressor Hard Start Kit internal thermal overload are used on all capacities assuring •Single-phase units are equipped with a PSC compressor longevity of high efficient and quiet operation for the life of the motor,this type of motor normally does not need a potential product. relay and start capacitor Each unit is shipped with filter drier for field installation and will •Kit may be required to increase the compressor starting trap any moisture or dirt that could contaminate the refrigerant torque,in conditions such as low voltage system. Low Ambient Kit •Air conditioners operate satisfactorily in the cooling mode down to 55T outdoor air temperature without any additional 2s controls •This Kit can be added in the field enabling unit to operate properly down to 00 in the cooling mode •Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit All cabinets have indust leading structural strength due to the 3"/6"/12" composite base pan(21 ,interlocking corner post(M),formed 'Gray high density polyethylene feet are available to raise unit curved louver panels(g)and drawn top cover(24)making it- off of mounting surface away from moisture the most durable cabinet on the market today. Low Pressure Each RA13 capacity has undergone rigorous psychometric test- " 'Can be added in field enabling the unit to shut off compressor ing to assure performance ratings of capacity,SEER and EER on loss of charge per AHRI Standard 210/240 rating conditions.Also NOTE:Unit can be purchased with high and low pressure each unit bears the UL mark and each unit is certified qt installed at factory.(Refer to SKU list) to UL 1995 safety standards. UM High Pressure Each unit has undergone specific strain and modal testing to •Can be added in field enabling unit to shut off compressor if _assure tubing(9E)is outside the units natural frequency and that unit loses outdoor fan operation. the suction and discharge lines connected to the compressor withstand any starting,steady state operation or shut down NOTE:Unit can be purchased with high and low pressure forces imposed by the compressor. installed at factory.(Refer to SKU list) All units have been sound tested in sound chamber to AHRI 270 Decorative Top rating conditions,and A-weighted Sound Power Level tables •Can be installed on fan grille produced,assuring units have acceptable noise qualities(see page 9).Each unit has been ran in cooling operation at 95°F and 82T and-sound ratings for the RA13 range from as low as 73 dBA,to 79 dBA. All units have been ship tested to assure units meet stringent "over the road"shipping conditions. As manufactured all units in the RA13 family have cooling capa- bility to 55 OF Addition of low ambient control will allow the unit to operate down to 0TF.Factory testing is performed on each unit.All component parts meet well defined specification and continually go through receiving inspections.Each component installed on a unit is scanned,assuring correct component uti- lization for a given unit capacity and voltage.All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled,each units'complete refrigerant system is helium leak tested.All units are fully charged from the factory for up to 15 feet of piping.All units are factory run tested. The RA13 has a 10-year conditional compressor and parts war- ranty(registration required). R A 13 24 -A J 1 N A D Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option Category -BTU/HRCode yCID Rheem A-Air Conditioners 13-13 SEER 18-18,000 [5.28 kW] A-1 st Design J-1 ph,208-230/60 1 -Single-stage N-Non-Communicating A-1 st Design N/A H 24-24,000 [7.03-kW] B-2nd Design C-3ph,208-230/60 B-2nd Design 30-,30,000 [8.79 kW]- D-3ph,460/60 CID 36-36,000 [10.55 kW]. 42'-42,000 [12.31 kW]. - w 48-48,000 [14.07W] 60-60,000[17.58 kW] *See page 3 for available SKUs. [ ]Designates Metric Conversions Air General Data/Electrical Data a RA13 Series Physical Data PHYSICAL DATA Model No. RA1318 RA1324 RA1330 RA1336 RA1342 RA1348 RA1360 Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0 Valve Connections Liquid Line 0 D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oz.s 54 60 72 86 105 106 148 Compressor Type Scroll Outdoor Coil Net face area-Outer Cod 5.9 9.1 9.1 12.1 14.2 14.8 18.8 Net face area-Inner Coil - - - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fns per inch 22 18 22 22 22 22 22 Outdoor Fan Diameter-in. 20 20 20 20 20 24' 26 Number of blades 2 2 3 3 2 3 2 Motor hp 1/8 1/8 1/4 1/4 1/8 1/6 1/5 CFM 2040 2325 2795 2900 2465 4145 3870 RPM 1075 1075 1075 1075 1075 850 820 watts 144 137 189 186 176 279 235 Shipping weight-lbs. 127 1 142 1 163 164 195 2-0-2 ---F-235 Operating weight-lbs. 120 135 1 156 157 188 195 228 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection(amps)' 20 25 30 35 40 50 60 Minimum circuit ampacity3 13 15 18 23 24 29 35 Compressor Rated load amps 9.7 11.2 1 12.8 1 167 1 17.9 21.8 26.4 Locked rotor amps 48 60.8 1 64 1 83.9 1 112 117 134 Condenser Fan Motor Full load amps 0.7 0.7 1.3 1.3 0.7 1 1.2 Locked rotor amps 1.3 1.3 2.5 2.6 1.3 2.2 2.0 Line Voltage Data (Volts-Phase-Hz) - - - 208/230-3-60 208/230-3-60 208/230-3-60 208/230.3-60 Maximum overcurrent protection(amps)2 - - - 20 30 30 35 Minimum circuit ampacity3 - - - 15 18 19 22 Compressor Rated load amps - - - 10.4 1 13.2 13.7 16 Locked rotor amps - - - 73 88 83.1 110 Condenser Fan Motor Full load amps - - - 1.3 07 1 1.3 Locked rotor amps - - - 2.6 1.3 2.2 2.0 Line Voltage Data (Volts-Phase-Hz) - - - 480-3-60 480-3-60 480-3-60 480-3-60 Maximum overcurrent protection(amps)2 - - - 15 15 15 15 Minimum circuit ampacity3 - - - 8 8 9 11 Compressor Rated load amps - - - 5.8 6.0 6.2 7.8 Locked rotor amps - - - 38 44 41 52 Condenser Fan Motor Full load amps - - - .6 .3 .6 .6 Locked rotor amps - - - 25 .9 1.6 1.1 Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation Instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. = D Air Accessories/Weighted Sound Power a I RA13 Series Accessories Model No. RA1318 RA1324 RA1330 RA1336 RA1342 RA1348 RA1360 Compressor crankcase heater' 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Compressor time delay RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 RXMD-B01 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 *Crankcase Heater recommended with Low Ambient Kit Weighted Sound Power Level (dBA) RA13 Sound Power Level Full Octave Linear Sound Power Level dB-Center Frequency-Hz Model Sound Power Level[dB(A)] 125 250 500 1000 2000 4000 8000 RA1318 72.0 51.7 58.3 61.5 61.1 570 54.0 47.0 RA1324 75.0 55.4 60.3 64.7 66.4 62.6 58 0 524 RA1330 78.0 51.4 67.1 67.5 68.2 65.5 59.8 53.6 RA1336 77.0 55.1 66.1 66.9 68.2 64.6 60.7 55.6 RA1342 73.0 48.9 56.1 62.9 62.2 61.1 55.2 50 2 RA1348 76.0 51.4 59.6' 65.2 65.9 64.3 58.5 53.7 RA1360 78.0 51.7 1 60.9 1 66.9 70.4 1 63.5 57.4 53.8 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) Air Unit Dimensions '0 I RA13 Series Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) NO. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA1318 27 685 2975 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1324 25 635 2975 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1330 25 635 29.75 755 29.75 755 1 26.75 679 32.38 822 32.38 822 RA1336 27 685 2975 755 29.75 755 2875 730 32.38 822 32.38 822 RA1342 31 787 29.75 755 29.75 755 32.75 831 32.38 822 32.38 822 RA1348 27 685 33.75 857 33.75 857 28.75 730 36.38 924 36.38 924 RA1360 31 787 3575 908 35.75 908 32.75 831 38.38 974 38.38 974 ALLOW 60"[1524 mm] OF CLEARANCE A W R D t S L N A L SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-02-00 -'oINTEGRATED'HOME CO �OTl CLEARANCES JLb D 'K'. `^ '�,.^„"�;r;;,sc .x sa,,': ;' ,? ,`"tz k^T vrr:� ;.t;a r`rzp ,-�- .s.,.,�,-. :.;cat,•s 3, I. Wy .'ig..x;,;';t,;.�','�"' °� '?"xni, ':,..�;xT,,.'.q.':'`e - - ,.,5- ,,;���,' �„ ..�', .,��. �h�,�`�'`���� x'Y•.,a '� ''A.a ,�,= t i �`� ,.a �;; ;�,_:r �.� �`»� ''s'y�., ,�, Nom, 'N�'°.';g*,.�-,`", �, "'�',�t`Y>�"��i. � .;ti;'. �tro~ a£i:;; a •�; ��s� : �.. A `�"��`""�.r a > � ,;.� �.'�Y d� L"�3�"'�`.,�,, :r�-t"�ss,�",�r•'-i-.1,'^ s,,," „��i:=c a.�P=�.� r. ,<,s�.; w��,x;R ^ ;' �^_"'�-tib, �.� �" s'�•`�i'"�`'�i",`f`Ss; ..�'^;tio S� '�^. 'i-�>;a��,�• .�,<.§;;fl.wpb,c.a4`aw-...,�-.,..��_.rs,�; F`."s"'"s.�z ^$�i`-`�Y�.�„'yw< 611 152.4 � 24 N (609.6) � Service u` 24" � 12 12 hy, (609Seryt 6) (304.8)- (304.8) '- ryr (152.4) 611 (152.4) 1211 (304.8) ,�„<=L'" ^bT;14'�`r✓:" - ,yay- 64E°� a••aa.w a;z' -:.��Y3.SYd iii. ^x4',1• -J m;Sa,.. 'e,;� „�:,t:; >,a' ^,+T', x3a, =o-r,c. ,�`r"' - =u'�, "�,+ .ya z, -fi"s'x,�^ ,� ~i.�..,< '.Y k�;+* .;'G'm ;_.ti,. .,; «itE�'•:•,"i..` Sze `�°`�.:"` o "�`n.>r�.:4�p�_',",`-`,"3�=`-sk..y,a�it:A-'`'��.'rr,�,s.r»,r�n;,s,`,-.f.;--'`.'k'�'7$•aE.�s�°,.F'�i�3.w4`"-:.`#-+d-.�,=ro,»:,.ri;�'h:i#%,-<�"'3.r"�.",_,e`�.„.'.'�n*,r,r�t.�,wv':�,C”sa'}�3s'5,wzw^r�:`g•�'<+,a.:.�'£''',�._�e=^rYggi-::ao','�r��,-i•�;'s~f",`.e.'r x•."�,;-3-:.`n<-n'.`,^s's-''`�ak,�'�,�«<a'.;s+a.'3,B',.+�il,�'°y/xte_a"+'.'.''°�"`.aa,r��-r,�aY,,>,_-'C,:'`^:f^'`esB f;:..a;�r.a,»:�,1.�''r''s�,ra,�„7.'``h-x«`-:Yu,-,<a�-."."�'`,,,d..�KW«,��",.,,,g'`L'W� Ag*�L,..L,..<r•r=.,�-r_.,.``+�,,':`v';`�#``�-'�•:;t:�:�`�.�`.,.�''�a�``?-t•",�.�.sg�".`,i*��.*-.._,�'r`�t,;>"=.�.�'-F>�v,,";t,.'�`.'.a�,„"*m-h,a.:.,�.`e�ro-z>_N._:x-,+s.n_'':,��,-,v'.<:s`Cb��t"�'•:<'�.€'t,"xnq_.-�t.,•<,>�.;,� ,.rK�� :� y.t • 24” 24" 24" (609.6) (609.6) (609.6 Service Service Service 18" 24" 24" (457.2) (609.6) (609.6) 24"recommended 24" recommended 9"minimum 9" minimum NOTE: NUMBERS IN O = mm IMPORTANT When installing multiple units in an alcove,roof well or partially enclosed area,ensure'there Is adequate venhllahon to prevent re-urculatlon of discharge air ST-A1225-01-00 AirWring Diagram/Application Guidelines aI RA13 Series Control Wiring FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(WBK)AND W2(W/BL)BE JUMPEREO TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE (y) © © ® Y G R OR-BROWN WIRE YL-YELLOW WIRE BR-BROWN WIRE X-WIRE CONNECTION R-RED WIRE YL-YELLOW WIRE WBK-WHITE WIRE WITH BLACK STRIPE GBK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX * W/BL TYPICAL CONDENSING R TYPICAL CONDENSING R UNIT UNIT X W/BK G/BK G YL Y YL YL BR BRX BR PU Application Guidelines 1.Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01 -in.wc. 2.Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55*F(12.8°C). 3.Maximum outdoor operating air temperature is 1250F,(51.70% 4.For reliable operation,unit should be level in all horizontal planes. 5.Use'only copper wire for electric connections at unit.Aluminum and clad aluminum-are not acceptable for the type of connector provided. 6.Do not apply capillary tube indoor coils to these,units. 7..Factory—supplied filter drier must be installed. .- Refrigerant Line Size Information JL6 13-16 SEER Single-Stage Air-Conditioners n Apply Long Line Equivalent Length(Feet) Allowable Allowable Guidelines If Linear Line a � Unit Size Liquid Line Suction Line Length Exceeds Those �25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 201-225 226-250 "o Size Size Shown Below (Feet) C )A13 AlB ; Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)•/Capacity Multiplier y CD 1/4' 5/8' 5s 25/1.00 50/0.99 62/0.98 43/0.98 24/0.97 5/0.97 fi "L' � NRS z �lti � , %►�R � N 5/16° 5/8' 25/1.00 50/099 75/0.98 98/0.98 93/0.97 88/0.97 a78%0:961 + 73%'Ot95�'s 1.5 TEoEn 3/8° 5/8' ::}.1 25/1.00 50/0.99 75/0.98 100/0.98 100/0.97 100/0.97 �""P0i7Q:96,sr100�/�0.961000,95; 100'%0:94 NOTE 3 1/4' 3/4"' � tN)A k 25/1.00 50/1.00 62/0.99 43/099 24/0.99 5/0.99 5/16° 3/4'** 25/1.00 50/1.00 75/0.99 98/0.99 93/0.99 88/0.99 83/0.99 78/0.98 73/0.98 68/0.98 3/8' 3/4"** ,178 25/1.00 50/1.00 75/1.00 100/0.99 100/099 100/0.99 100/0.99 100/0.98 100/098 100/098 1/4' 5/8° > `s" "' NlA 25/0.99 50/0.98 21/0.97 M@NW�> <M;Hy °NR sNRi ;' �I I " '� tom, m K ,�Z �, �; ro 25/0.99 50 0.98 75 0.97 5/16° 5/8° 213 / / 87-10 96 77`'1`>0 95 69.10=94` fit 0 93 �.�,. rc$.�m �:. _s_ .�} #�.�� �''��-�,.. .:,�,,xam. •r�, �F �a:,�..,r/�0�92-� 3/8° 5/8° °1A? xM 25/0.99 50/0.98 75/0.97 ;1.00.%0 96`X100;/0 95a 1'Q0,/0.94 ,98/,fl:$3 95`!>069� X92=/,09_1 . 89',%`0'90 ` 2TOn e _��a, z _ �a .� 1/4' 3/4° " N!A £; 25/1.00 50/1.00 21/0.99 5/16" 3/4' X213 25/1.00 50/1.00 75/0.99 87/0.99 77/0.98 69/0.98 61/0.98 53/0.97 45/0.97 3/8' 3/4° " 142 : " ='}' 25/1.00 50/1.00 75/0.99 100/0.99 100/0.98 100/0.98 98/0.98 95/0.97 93/0 97 '901096 ry 5/16' 5/8" tla flw„� , , a r v r, q .,�4 / k, NA25/0.99 50/0 98 �75 ;Q.96>, X70;/.;Q 94V,+ 5,9i�U:93sr. ;48L,Q.;91;:,;,W 36%Q:90<; ��IR _NR 3/8' 5/8* "` '";aw r 'y R` vyf Y _ - i 4_ n y k �a / �� '�.:�142: ar;;�. 25/0.99 50/0.98 2.5 Ton ., 5/16" 3/4° L13P,'4 25/1.00 50/0.99 75/0.99 70/0.98 59/0.98 48/0.97 / 3/8° 3/4° 25/1.00 50/0.99 75/0.99 100/0.98 98/0.98 94/0.97 z 90r/'Ot96":= ;86*/`0:96` G`82/0:95r`'=8/Ui95'" f, ._ �. S 5/16° s- '-s;;^*� .` -..�,;; , ..;,. :;., ., . .. .� 5/8' N/Ae° 25 0.99 50 0 97 ', L� v a� ��«;�° / / 66;%0:94;, �"�49/.-0:92#''•�„�3$/-0:90,;;-; ','��R� 2�;_,, �NFi NR� iVR �'t '�. '"R�.;� :a n..y..�'a.. ,'{ i�w ..i„ ` ,-"i-t,. •�:�`'ce;+w t a> /8' a j; r 1 ,_. ., �;�r ..f ... -." tiR n NR 318' 5sc 08 „ e 25/0.99 50/0 97751094' _X95_ "" Y LL%0:92 ; ',89 :0:90-=; 01119Ft.7n NR. ,_= NRS s` �a '.,_OWN �5-,'km _,"c A i£";r"' �. •w »2 ..,..x 5/16" 3/4° �.NIAy`t,_ ' 25/1.00 50/0.99 66/098 49/0.98 32/0.97 3/8' 3/4° rs"�?.",x108 °_<" J'�r' 25/1.00 50/0.99 75/0.98 95/0.98 89/0.97 .8�4%;0"`96` �X78'%0'95; 72%094' 67 x0.93 f` 61°1093:�> 3 Ton . :,._ .u... : : ., v. ..: 1/2' 3/4° "== *;':,x:54F;° 25/100 50/099 75/0.98 100/098 100/0.97 5/16° 7/8' R; 25/1.00 50/1.00 66/1.00 49/0.99 32/0.99 15/0.99 °MR 4 +hIR 3 5-PEN .33':sl ?;Y rt?.'srY :S':--5. 5._ ♦�r.F:4�-a.- � 3/8' 718° 25/1.00, 50/100 75/1.00 95/0.99 89/0.99 84/0.99 78/0.98 72/0.98 67/0.98 61/097 1/2' 7/8' 25/1.00 50/1.00 75/1.00 100/0.99 100/0.99 100/0.99 100/0.98 100/0.98 100/0.98 100/097 rn .y `' 150'a Y.1;A ,.� 25/0.99 3/8° 3/4' __ _ .�< ,�- ,��;F��; 75/0.97 1/2' 3/4° �:;°i x'75 „ '. 25 0 T.;n. ,fl0,�� • 3 5 Ton es. .� �� / .99 50/0.98 75/0.97 z1 Q=%'0;9G•. ;100%095 10 1Q;94WOO I�Q:92;� 'x 100 7.0;9J 1 / rl W 3/8" 7/8' 150 25/1.00 50/1.00 75/0.99 1 88/0.99 80/0.99 72/0.98 65/097 57/0 9749f1,A96>>,;= 42%x0)96 1/2' 7/8' 75 c = 25/1.00 50/1.00 75/0.99 100/0.99 100/0.99 100/0.98 100/0.97 100/0 97 1007`0:9fi _:=.100%0;95 r. .. NOTES: 1)Do not exceed 200 ft linear line length 2) *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. 3)*'3/4'suction line should only be used for 15 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return 4)Always use the smallest liquid line allowable to minimize refrigerant charge 5)Applications shaded in light gray indicate capacity multipliers between 0 90 and 0 96 which are'not recommended,but are allowed. 6)Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. Refrigerant Line Size Information (con't.) 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Equivalent Length(Feet) Allowable Allowable Guidelines If Linear Line Length Exceeds Those Unit Size Liquid Line Suction Line Shown Below (Feet) <25 26-50 51-75 76-100 101-125 126-150 151.175 176.200 201.225 226-250 Size Size e �1A13fy �' Maximum Vertical Rise(Outdoor Unit Below Indoor Unit) /Capacity Multiplier F:4Y aa..'YFmW 3/8" 3/4° 1481 ^` 25/0.99 50 0.98 r* r,-. ._, :flf; '". �.rx ,,: •. ': = :� / �7.5,(£a:96, i„<-,n,, .sml .. > 7w.aY x. c;.t°., !v. ,;3�:•. g .i•.ate,hL. 1/2" 3/4° ct, .74 g 25/0.99 50/0.98 d t : 4 Ton / 75',/.,f)96 1„00`%095~ ,100/0 93, fi•00<%Q.92 25/1.00 50/0.99 75/0.99 77/0.98 67/0.97 57/0.97 , 4E^ 09fi,�--. ,,W-/' 026'•%0.95;; 5/�0:95��, 25/1.00 50/0.99 75/0.99 100/0.98 100/0.97 100/0.9700 0:96 :10Q%d 86' X99 #a85"' t.977 UPJ 3/8° 3 _ 8 25/0.99 50/0.97 j_- U192a 46 NR , � U;9Qs'•9'9,1.�. �1 _ � 5 i � 1/2° 3/4° '9f 25/0.99 50/0.97 " 750 94 tOd 0 921`0( U 90 F) " . / � �$'`� , 25 1.00 0'96 . {,�;95 h S"X094' = ; 3/8° 7 8° ��° / 50/0.99 75/0.98 61/0.97 a < ' f: - ,>.;,�, W I 5 Ton ,., 1/2° 7/8° 25/1.00 50/0.99 75/0.98 100/0.97 1Q .95< 00149 °'19 0:�4 _'�"95 09 i 92 tox �� =� �? �' �j>,..�� ��._�,��,` ��,Y�0:9S',� f 89;140 92M; 3/8° 1-1/8' 25/1.01 50/1.01 75/1.00 61/1.00 46/0.99 32/0.99 18/0.99 N$ = - � - � y ws 1/2° 1-1/8' �r;",, 25'/1.01 50/1.01 75/1.00 100/1.00 100/0.99 100/0.99 97/0.99 95/0.99 92/0.99 89/0.98 NOTES: 1)Do not exceed 200 ft linear line length. 2) 'Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit. 3)•°3/4'suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return. 4)Always use the smallest liquid line allowable to minimize refrigerant charge. 5)Applications shaded in light gray indicate capacity multipliers between 0 90 and 0.96 which are not recommended,but are allowed. 6)Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. JL6 D D � w Ch N W d w r 5 N (D 7 O w 0 Refrigerant Line Size Information JLb 13-16 SEER Single-Stage Air-Conditioners D Apply Long Line Equivalent Length(Meters) Allowable Allowable Guidelines if Linear Line j Liquid Line Suction Line Length Exceeds Those Unit Size Size Size Shawn Below (Meters) <8 8-15 16-23 24-30 31-38 39-46 47-53 54-61 62-69 70-76 yca CD CD mm[In.] mm[in.] Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)•/Capacity Multiplier y r 5 CD 6.35 [1/4] 15.88[5/8] aN/A zi` zwayt 8/1-00 15/0.99 19/0.98 13/0.98 710.97 2/0.97 � Pi�R "-HN i`1Vi � 5.3 kW 7.94 5/16 15 8 `z ri .z µ> law;,` r / � r q x; [ ] x,�.fin .N)A';, s 8/1.00 15 0.99 23 0.98 30/0.98 28 0.97 27/0.97 .2x;096 x 24/_-(3:96 [1.5 Ton] 9.53 [3/8] 15.8815/ s` r54 "°,fir aF"' 15/0.99 23/0.98 30 0.98 ] 4" , r''r= 1 ""SEE "" 'x;a 8/1.00 / 30/0.97 30/0.97 ,;:30;%0.96,�.;,..30r/0 96 4 02AA 1" f.30*%`0.9,4F' g 6.35 [1/4] 19.05[3/4] `iN ;{�k ar,NIH�< w.}F,:,4, 8/1.00 15/1.00 19/099 13/0.99 7/0.99 2/0.99IREI�R. 2 "[NR&pr�"` NR o NOTE 3 .. ` . �roy� 5,., E5 7.94[5/16] 19.05[3/4] ;;,�, N� � R 8/1.00 15/1.00 23/0.99 30/0.99 28/0.99 27/0.99 25/0.99 24/0.98 22/0.98 21/0.98 9.53 [3/8] 19.05[3/4]"* 4 'z g, 8/1.00 15/1.00 23/0.99 30/0.99 30/0.99 30/0.99 30/0.99 30/098 30/0.98 30/098 6.35 [1/4] ;� r. n ? xt a � 15.88[5/8] N%A 8/0.99 15/0.98 6/0.97 _� jj � '' "s ,{„,,, Rr*' ts�"�`�-a, a` :., r� ``£�s ;. �s' �_ v.e'"s+. �Ij� 5.88 5 Bra r .: ,,. . ,.. ,, :M�, <K 7.94[5/161 1 [ / ) �M 8/0.99 15/0.98 23 0.97 ;,, .. ,�$ °�.-. , •._:, a` 65 - ` / 27y%b 96, 2310: 521 _ t ; ^ � ...���. ���:�, �, <`� ��%Om94 � 15nL40.93i� {i;,6t��0:92u4,=�1�4./A.91,=�v 7 0 kW 9.53 [3/8] 15.88 5/8 8/0.99 15/0.98 23/0.97 30%d:96` 3Q/'0.9 ,; z>> � 5 �30,�:0:94 29�/� .92-M,- ��; � a.�; „>-�_. �� ��<,�_ �.;�. �0 .�: =�28„/�0.91�x��s21%�Oi9b.�,` [2 Tont ,, ' -may , .., . . r . . 6.35 [1/4] 19.05[3/4] , N/A vr € 8/1.00 15/1.00 6 0.99 SlR x _ 7.94[5/16] 19.05[3/4] 8/1.00 15/1.00 23/0.99 27/0.99 23/0.98 21/0.98 19/0.98 16/0.97 14/0.97 1`096 e 9.53 [3/8] 19.05[3/4] 43 ; ` § ' 8/100 15/1.00 23/0.99 30/0.99 30/0.98 30/0.98 30/0.98 29/097 28/0.97 7.94[5/16] 15 88 5/8 s - _ r ; [ 1 z_ k`°�N/A; ± :', 8/0 99 15/0.98 23%;0:96 x`21 10'94.== �1,8'.0:931,5; 0.9fi;t= x 1il`/Q90 Fi( NR R' # 8.8 kW 9 53 [3/8) 15 88[5/8] 0. 43x ; ,, = ,,- 8/0 99 15/098 :' -..<_ _ _ , ., x _ r; SKr. 23;10;96; X30%`0:94_ >.30`1'093' 29,/Q.91 �' 27 0.90` i{SNR. NR fJR' [2.5 Ton] 7.94 5/16 19.05 34 ;e _; . _ _ , 18/0.9 , _ s� [ 1 [ / ] „ r1; 65 � Ua _ 8/100 15/0.99 23/0.99 21/098 18/0.98 15/0.97 %0:96rn81'0.96;�=' 9.53 3/8 19.05 3 4F - r,. � [ I [ / I 8/1.00 15/0.99 23/0.99 30/0.98 30/0.98 29/0.97 `- � • 7.948/0.99 [5/16] 15.88[5/8] � 15/0.97 20%'0:94 ki'S 092 ` • �;x�-' ,- -`. >: -�-� . ° f 9 53 [3/81 15.88[5 8] 8/0.99 15/0.97 ��xR��r.;,'_�}��'=`•N^gyR�' -;�.-„;N-R�„"?- .,rsR:O�R � s .98 10/0.97i 7.94[5/16] 19.05[3/4] 8/1.00 15/0.99 20/098 15/0.98 • 10.6 kW 9.53 [3/8] 19.05[3/4] r33 �`m `k x+w. 8/1.00 15/0.99 23/0.98 29/0.98 27/0.9726 ; r 3Tan „u=,:,;; X0:96:;° 24%0:95, 22`�=0s94.. [ ] 12.7 1/2 19 05 3/4 :`asx; = y8/1.00r 0%'0?9fi'`"30%<0;95 '"30%0;94:"''^$0•/90:9 [ I [ I :MsA;p `z17s,, ;µ, t, 23/0 98 ".r`< 3, 7.94[5/16] 22.23[7/8] 8/1.00 15/1.00 20/1.00 15/0.99 10/0.99 5/0.99 : N11 NR ; ' 9.53 [3/8] 22.23[7/8] 33 r''^" 4z'. 8/1.00 15/1.00 23/1.00 29/0.99 27/0.99 26/0.99 24/0.98 22/0.98 20/098 19/097 1/2 [12.71 22.23[7/8] ;? 1Tr " 8/1.00 15/1.00 23/1.00 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 30/0.97 9.53 [3/8] 19.05[3/4] w; sv �w46t � „'- 1 8/0.99 15/0.981 23/097 :27(-;0:96=,=;r24%095 :22/0;94%;F�20a(0392y r�:�1:710:91'w 15x/°,;0 902j111ii�v 12.3 kW 12.7 1/2 19.05 3/4Pe4xr,�. '';23srti ;; ;` [ 1 I l ax=", 8/0.99 15/0.98 23/0.97 .3010'.:9'6° 30/d'.95 w', 30�/A;94a�, ,. .-'4,,.,� - 30'/0:927 ^;`30„Os9 [3 5 Tont 9.53 [3/8] 22.23[7/8] 8/1.00 15/1.00 23/0.99 27/0.99 + _24/0.99 22/098 . 20/0.97 17/0.97 X15%Q96 Ei3%:96r 12.7 [1/2] 22.23[7/8] ; w 23 8/1.00 15/1.00 1 23/0.99 30/0.99 30/0.99 30/0.98 30/0.97 30/0.97 30%M96:-Y; 3U096 NOTES., 1)Do not exceed 61 meters linear line length. 2)*Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit. 3)*19.05 mm 13/4 in.]vapor line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4)Always use the smallest liquid line allowable to minimize refrigerant charge. 5)Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended,but are allowed 6)Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop [ ]Designates Metric Conversions Refrigerant Line Size Information (con't.) 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Equivalent Length(Meters) Allowable Allowable Guidelines if Linear Line Liquid Line Suction Line Length Exceeds Those Unit Size Size Size Shown Below (Meters) <8 8'15 16-23 24-30 31-38 39-46 47-53 54-61 62-69 70-76 mm[in.] mm[in.] F t�A1a3tW" ` � Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)`/Capacity Multiplier t}��f;iRa�cN€ C u 9.53 3/8 19.05 3/41 m, ��> �. uss� r,-tip t.�. r [ 1 [ 1 8/0.99 15/0.98 <231j0:9;& 'F2410:95'. 4",.„20, i.x Lwb',93`;_ � tG�0�92�ys 14,'+14.91';a P. a �li, . 141 W 12.7 1/2 19.05 3/4 ;, „ � :23;.u, A'v 8/0.99 15 0.98 ffl k [ l [ 1 fiz / All[4 Ton] 9.53 3/8 22.23 7 8 ^3 =? k U 54 [ ] [ / ] k� 46 8/1.00 15/0.99 23/0.99 24/0.98 20 0.97 ; 09 t .96 8�0.955 �95�u��/ 17/0.97 14% 6 '18,96 �� 12.7[1/2] 22.23[7/8] 23? 8/1.00 15/0.99 23/0.99 30/0.98 30/0.97 30/0.97 "'x90F/096 ; `301i096$3 '=301095M`30%0:95 9.53 3/8 19.05 3 4 t ;� {- 5 u � [ 1 [ / ] 4> 24 s , 8/0.99 15/0.97 ,2$;10.94`" 19r/0:92_„ 14/ H NR : I .i N�.IN�� ,Nq ` �,-:3r`4 ,.,' (ate k 12.7 1/2 19.05 3/4 "12T. ` 8/0.99 15 0.97 =�";2 "� 't � ' [ ) [ lex -: ..� / 3.Ia03 Q92 30�/.'0.9Qa �N , � N 9.53[3/8] 22.23[7/8] �°�` -, �r- « >,n� . _�° M.. � - �� � ..��.� �"� 17 6 kW 9.53 8/1.00 15/0.99 23 0.98 19 0.97 X10"I,09 '� 5%=0¢94R rNH l� ttz, ;.G`a,.- ,.v �;"r,'. [S Ton] 12.7[1/2] 22.23[7/8] 12' 8/1.00 15/0.99 23/0.98 30/0 97 3a/0 96j '3i i0536:%09;4 e29 X0;94 28 ' .� ' 9.53[3/8] 28.58[1-1/8] �� 24 8/1.01 15/1.01 23/1.00 19/1.00 14/0.99 10/0.99 5/0.99 t• �'°.� 12.7[1/2] 28.58[1-1/8] r 8/101 15/1.01 23/1.00 30/1.00 1 30/0.99 1 30/0.99 30/0.99 29/0.99 28/0.99 27/098 NOTES: 1)Do not exceed 61 meters linear line length. 2)'Do not exceed 30 meters vertical separation if outdoor unit is above indoor unit. 3)•19.05 mm[3/4 in.]vapor line should only be used for 15 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return. 4)Always use the smallest liquid line allowable to minimize refrigerant charge. 5)Applications shaded in light gray Indicate capacity multipliers between 0.90 and 0 96 which are not recommended,but are allowed. 6)Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. [ ]Designates Metric Conversions JL6 D A C D CD C4(a m W w =. m H _r CD CD N fD 7 O 3 w 0 Air Performance Data a I RA13 Series Performance Data @ AHRI Standard Conditions- Cooling Designated Tested Combination(DTC) Outdoor Total Capacity Net Sensible Net Latent Indoor CFM Unit Indoor Coil BTU/H[kW] BTU/H[kW] BTU/H[kW] SEER EER [Us] RA1318 RCF2417STA 17600 [5.2] 12600 [3.7] 5000[1.5] 13.00 11.00 600[283.2] RA1324 RCF2417STA 23400 [6.9] 17500 [5.1] 7000[2.1] 13.00 11.00 800[377.6] RA1330 RCF3617STA 28400 [8.3] 21000 [6.2] 7400[2.2] 13.00 11.00 1000[471.9] RA1336 RGF3617STA 34600[10.1] 23400 [6.9] 11200[3.3] 13.00 11.00 1025[483.7] RA1342 RCF4821STA 40500[11.9] 28700 [8.4] 11800[3.5] 13.00 11.00 1400[660.7] RA1348 RCF4821STA 47500[13.9] 34000[10 0] 13500[4.0] 13.00 11.00 1500[707 9] RA1360 RGF6024STA 56000[16.4] 39600[11.6] 16400[4.8] 13.00 11.00 1600[755.1] Note:Additional ratings and system match ups can be accessed on MyRheem.com at:https://my.rheem.com/static/private/ahriresidental.html Additional ratings and system match ups and downloadable ratings cerblicates can be accessed from the AHRI website:www.ahridirectory.org [ ]Designates Metric Conversions 16 . • • •- —DI Air Guide Specifications a RA13 Series GUIDE SPECIFICATIONS General AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER System Description RA13 Outdoor-mounted, air-cooled, split-system air conditioner com- 1-1/2 TO 5 NOMINAL TONS posite base pan unit suitable for ground or rooftop installation. Fans Unit consists of a hermetic compressor, an air-cooled coil, pro- —Condenser fan will be direct-drive propeller type, discharging peller-type condenser fan, suction and legend line service valve, air upward. and a control box.Unit will discharge supply air upward as shown —Condenser fan motors will be totally enclosed, 1-phase type on contract drawings. Unit will be used in a refrigeration circuit to with class B insulation and permanently lubricated bearings. match up to a coil unit. Shafts will be corrosion resistant. Quality Assurance —Fan blades will be statically and dynamically balanced. —Unit will be rated in accordance with the latest edition of AHRI —Condenser fan openings will be equipped with coated steel Standard 210. wire safety guards. —Unit will be certified for capacity and efficiency, and listed in Compressor the latest AHRI directory. —Compressor will be hermetically sealed. —Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. —Compressor will be mounted on rubber vibration isolators. —Unit will be constructed in accordance with UL standards and Condenser Coil will carry the UL label of approval. Unit will have c-UL-us —Condenser coil will be air cooled. approval. —Coil will be constructed of aluminum fins mechanically bonded —Unit cabinet will be capable of withstanding ASTM 13117 1000- to copper tubes. hr salt spray test. Refrigeration Components —Air-cooled condenser coils will be leak tested at 150 psig and —Refrigeration circuit components will include liquid-line shutoff pressure tested at 550 psig. valve with sweat connections, vapor-line shutoff valve with —Unit constructed in IS09001 approved facility. sweat connections, system charge of R-410A refrigerant, and Delivery,Storage,and Handling compressor oil. —Unit will be shipped as single package only and is stored and —Unit will be equipped with filter drier for R-41 OA refrigerant for handled per unit manufacturer's recommendations. field installation. Warranty(for inclusion by specifying engineer)—U.S.and Operating Characteristics Canada only. —The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption Products at full load will not exceed kW. —Combination of the unit and the evaporator or fan coil unit will Equipment have a total net cooling capacity of Btuh or greater at Factory assembled, single piece, air-cooled air conditioner unit. conditions of CFM entering air temperature at the evap- Contained within the unit enclosure is all factory wiring, piping, orator at °F/°C wet bulb and °F/°C dry bulb, and controls,compressor,refrigerant charge R-410A,and special fea- air entering the unit at °F/°C. tures required prior to field start-up. —The system will have a SEER of Btuh/watt or greater at Unit Cabinet DOE conditions. —Unit cabinet will be constructed of galvanized steel, bonder- Electrical Requirements ized,and coated with a powder coat paint. —Nominal unit electrical characteristics will be v, single —All units constructed with louver coil protection and corner post. phase,60 hz.The unit will be capable of satisfactory operation Louver can be removed by removing one fastener per louver within voltage limits of v to V. panel. —Nominal unit electrical characteristics will be v, three phase,60 hz.The unit will be capable of satisfactory operation within voltage limits of v to V. —Unit electrical power will be single point connection. —Control circuit will be 24v. Special Features —Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Air Limited Warranty 0 RAI 3 Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required)...............................Ten(10)Years period stated,in accordance with the terms of the limited warranty. 'For complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. RATED • • •- .'7777- 1 .. -_'' �_-.;-:�:�=.�'T.�.'�=�";�rx �'f,:r=r,,tt�.„y�: �sa;,':�'r;:'�,i�>'� =`;The;newdegreeofacomtortkx2:> -.'� i;-•�-�-:_. :< .^ " _ In keeping with Its policy of continuous progress and product improvement Rheem reserves the nght to make changes without notice. Rheem Heating,Cooling&Water Heating 5600 Old Greenwood Road Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72908 • www.rheem com Brampton,Ontario L6Y OP5 �OIVIE 6C6RT'�',`." PRINTED IN U S A.2121 OG FORM NO A11-221 REV 9