Loading...
HomeMy WebLinkAbout46486-Z �o�OS�FF G, , Town of Southold 8/14/2021 P.O.Box 1179 0 o ` 53095 Main Rd 4,1 �aQfi' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42237 Date: 8/14/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 250 Wells Rd,Laurel SCTM#: 473889 Sec/Block/Lot: 126.-9-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/17/2021 pursuant to which Building Permit No. 46486 dated 6/24/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as aapplied for. The certificate is issued to Berberich,Michael&Stephanie of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46486 7/23/2021 PLUMBERS CERTIFICATION DATED A o zed ature o�gUfF � TOWN OF SOUTHOLD aye BUILDING DEPARTMENT C* TOWN CLERK'S OFFICE Wo . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46486 Date: 6/24/2021 Permission is hereby granted to: Berberich, Michael 250 Wells Rd Laurel, NY 11948 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 250 Wells Rd, Laurel SCTM # 473889 Sec/Block/Lot# 126.-9-6 Pursuant to application dated 6/17/2021 and approved by the Building Inspector. To expire on 12/24/2022. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 Total: $200.00 Build Inspector ®f S Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.deviin()-town.southold.ny.us Southold,NY 11971-0959 sd° BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Michael Berberich Address: 250 Wells Rd city,Laurel st: NY zip: 11948 Budding Permit# 46486 Section- Block Lot: WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Long Island Power Solutions License No. 36178ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 23q Switches 4'LED Exit Fixtures Pump Other Equipment 7.820kW Roof Mounted PV Solar Energy System w/ (23) Qpeak DuoG6- 340W Panels, Enphase IQ3 Combiner 220x2 215x1, 23A AC Disconnect Notes. Solar Inspector Signature: Date: July 23, 2021 S. Devlin-Cert Electrical Compliance Form SOF SOUTyo l5/ Y w - # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]--INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] -ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: r AJ X446 t 4-1� i DATE - /02,, 3/ INSPECTOR �. * TOWN OF SOUTHOLD BUILDING-DEPT. WON, 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO GH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL �al [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: O DATE Y ZO INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) �y ------------------------------------ C FOUNDATION(2ND) z �o c ROUGH FRAMING& PLUMBING 1 r INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS a� 1 s O ' n Srn X N y • O �C y Q�OS�yPFD(K��o TOWN OF SOUTHOLD—BUILDING DEPARTMENT y� Town Hall Annex 54375 Main Road P. O.Box 1179 Southold,NY 11971-0959 Telephone (631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny.gov Date Received APPUCATION FOR BWLMNG PERMIT For Office Use Only y � .I �• , � j PERMIT NO. Building Inspector: {'� ' JUN 1 7 2021 Applications and forms must be filled out in their entiret . ncomplete applications will not be accepted. Where the Applicant is not the owner,an 71_ T-7 7 .­jf;pEPT. Owner's Authorization form(Page 2)shall be completed.-,, ,, j Date: OWNERS)OF PROPERTY: Name:Stephanie Berberich PETM #1000-126-9-6 Physical Address:250 Wells Road, Laurel, NY 11948 Phone#:631-871-0235 Email:smincieli 1 5@gmaii.com Mailing Address:250 Wells Road, Laurel, NY 11948 CONTACT PERSON: Name:Sue Estabrooke/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:sue@longislandpowersolutions.com 'DESIGN PROFESSIONAL INFORMATION: Name:Fisher Engineering Services, P.C. Mailing Address:509 Sayville Blvd., Sayville, NY 11782 Phone#: 631-786-4419 Email:bill@fisher-ny.com CONTRACTOR INFORMATION: Name:Michael Catizone/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:mike@longislandpowersolutions.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration []Repair ❑Demolition Estimated Cost of Project: ®Other Proposed(23)panel roof mounted array. (7.820)kW System $16,4 11.16 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 L PROPERTY'INFORMATION- • . Existing use of property:Single Family Dwelling Intended use of property:Single Family Dwelling Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes ®No IF YES, PROVIDE A COPY. 8 Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm water issues'as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for.the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises,and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Catizo a Electrical/Long Island kower Sol�tions Application Submitted By t n •�,c- �e,_\,\ZA Y\-Q—, @Ruth rite Agent ❑Owner Signature of Applican . Date: S41 74 STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this d. 20 a-\ LYNDE SUSETTE ESTABROOAF Notary Public NOTARY PUBLIC,STATE OF NEW YORK Registration-No. 01 ES6259997 Qualified in Dutchess County pR pERTY OWNER AUTHOWZATiI®N Commission Expires April 16,20 here the applicant is not the owner) I, � �' � zl� residing at Michael Catizone/Long Island Power Solutions �\_4LR� do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. .5-12 -2.1 Own is Signature Date rint Owner's Name 2 S�EOt,� BUILDING DEPARTMENT- Electrical Inspector LI$ TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 at Telephone (631) 765-1802 - FAX (631) 765-9502 �'ISV rogerr .southoldtownny.aov,— seand(.W-southoldtownnygov, APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Catizone Electrical Long Island Power Solutions Name:Michael Catizone License No.:36178-ME email: sue@longislandpowersolutions.com Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (All Information Required) Name: Stephanie Berberich Address:.250 Wells Road,Laurel,NY 11948 Cross Street:Bray Ave Phone No.: (631)8'71-0235 Bldg.Permit M email: cedwardsimon@gmail.com Tax-Map District: 1000 Section: 126 Block: 9 Lot:,6 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed(23)panel roof mounted array. (7.820)kW System Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters _ Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected- Underground-Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: Inverters: (23)Enphase IQ-7 Modules: (23)Hanwha Q.Peak Duo, Q-Cell 340W Support:Iron Ridge XR 100 PAYMENT DUE WITH APPLICATION Request for Inspection Form.As l 2( � �o PERMIT# Address: Switches Q 137 Outlets GFI's '•��9 Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator -- - - ---- - ------- --------- --- --- ----- ------- - Combo - - - - - - - -- - Cooktop - - Transfer AC AH Mini Special: Comments l Suffolk County Dept of Labor,Llcensin&Cc-Urrier Affairs tASTER ELECTRICAL LICENSE Name WCHAEL J CATIZONE NSMO TOIS Cqnfiar trial the L*Veris dutj licaimed Catmune Eter*icel Corl-adrig lqr. by ft C.ointy ol sedk Ucintima Number:fAE-3617H Roadyle oTago Issued: 120 1 QM 4 fixplresL I201112022 Suffolk County Dept of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name MICHAEL CATIZONE Business Name This certifies that the LONG ISLAND POWER SOLUTIONS INC bearer Is duly licensed by the County of suffolk License Number:ME-53560 Rosalie Drago Issued: 0610612014 Commissioner Expires: 0610112022 Suffolk County Dept.of Labor,Licensing&Consumer Affairs HOME IMPROVEMENT LICENSE Name MICHAEL J CATIZONE Business Name This certifies that the LONG ISLAND POWER SOLUTIONS INC bearer is duly licensed by the County of,suffolk License Number:H-53562 Rosalie Drago Issued: 0610612014 Commissioner Expires: 06/0'112022 INEW Workers' CERTIFICATE OF ATE Com'ensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Catizone Electrical Inc 631348-0001 575 Lexington Avenue,4th Floor - New York, NY 10022 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 455213112 Flame and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Utica Mutual Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box 1 a" 53095 Route 25 766763 3c.Policy effective period Southold,NY 11971 07/01/2020 to 07/01/2021 3d.The Proprietor,Partners or Executive Officers are ❑ included.(only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carver or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Leonard Scioscia (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 9/17/20 (Signature) (Date) Title: Authorized Representative Telephone Number of authorized representative or licensed agent of insurance carrier: 631-390-9700 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov Client#:83176 CATIELE DATE(MWDD/YYYY) AC®RM CERTIFICATE OF LIABILITY INSURANCE 1 6/17/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Cook Maran Cook Maran&Associatesa/CO No Et):6313909700 FAX ac No 40 Marcus Drive E-MAIL ADDRESS certificates@cookmaran.com 3rd Floor INSURER(S)AFFORDING COVERAGE NAIC# Melville,NY 11747-2647 INSURER A:Utica Mutual Insurance Company 25976 INSURED INSURER B Catizone Electrical Contracting Inc. INSURER C: 2060 Ocean Avenue INSURER D• Ronkonkoma,NY 11779 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE I SR WVD ADDLISUBR POLICY NUMBER POLICY EFF MM/DDD/YYYY XP LIMBS A X COMMERCIAL GENERAL LIABILITY CPP4784747 7/01/2020 07/01/2021 EACH OCCURRENCE $110009000 CLAIMS-MADE 7 OCCUR PREMISES EaEOccaurrenoe $100,000 MED EXP(Any one person) $10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $2,000,000 PR - X POLICY[__1 ECT 7 LOC PRODUCTS-COMP/OPAGG $2,000,000 OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident UMBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ r $ A WORKERS COMPENSATION 4766763 7/01/2020 07/01/2021 X IsPTEARTuTE ER AND EMPLOYERS'LIABILITY OFFIBEPROPRIETOR/PARTNER/EXECUTIVE Y N/A E.I. EACH ACCIDENT s500,000 (Mandatory In NH) E.L DISEASE-EA EMPLOYEE 000,000 If es,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space is required) CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S2534247/M2522457 CPRAV YORK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured CATIZONE ELECTRICAL INC 575 LEXINGTON AVENUE,4TH FLOOR 646-383-3599 NEW YORK, NY 10022 Work Location of Insured(Only required ifcoverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,i.e.,Wrap-up Policy) or Social Security Number 45-5213112 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Town of Southhold Standard Security Life Insurance Company of New York 53095 Route 25 3b.Policy Number of Entity Listed in Box"1 a" Southold, NY 11971 R97483-002 3c. Policy effective period 1/1/2020 to 9/15/2021 4. Policy provides the following benefits: Q A.Both disability and paid family leave benefits. ❑ B.Disability benefits only. F] C.Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as descojbd above. Date Signed 9/16/2020 By �60A. (,Q.41Tnit (Signature of insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 51B Is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers' Compensation Board(only if Box 4C or 56 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees Date Signed By (Signature of Authorized NYS workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 111111111 !��°!°�11°°°°°����11°11°111°IIIII1 LONG ISLAND OWER2060 Ocean Ave Ronkonkoma, NY 11779 S®1 1�✓T I O 1�1 S 631348-0001 6� �1 www.longislandpowersolutions.com TOWN OF SOUTHOLD—Building Division JUN 1 7 2021 Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: Stephanie Berberich—631-871-0235 Project/Property Address: 250 Wells Rd., Laurel,NY 11948 Section/Block/Lot: 1000-126-9-6 Electrician/36178-ME: Michael Catizone—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Contractor/53562-H: LI Power Solutions—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Architecture&Planning: Fisher Engineering Svcs.-509 Sayville Blvd., Sayville,NY 11782—631-786-4419 Enclosed Please find: • Application Fee: $200.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings& Specs • Liability, Disability& Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further, please contact me. Sincerely, Sue Estabrooke Permit Manager Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 sue@Gopowersolutions.com G® Greer Save Greer AAPRO AS NOT D DATgp # FEE- BY: NOTIFY:,BUILDING DEPARTMENT AT 7651802 •8 AM TO 4 PM FOR THE FOLLOWING;INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH'-,FRAMING & PLUMBING 3. INSULATION, 4: FINAL CONSTRUCTION MUST BE-COMPLETE FOR CO. - ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR ELECTRICAL DESIGN OR CONSTRUCTION ERRORS. WSPECTION REQUIRED COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF BOARD g0UTA0[D70Wty i RUSTEES OCCUPANCY OR USE [$:UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY- Y Fisher Engineering Services, P.C. 509 Sayville Blvd • Sayville •New York 11782 Phone: (631) 786-4419 March 12, 2021 Attention: Town of Southold Building Department 54375 NY-25 Southold,NY 11971 Subject: Solar Energy Installation for Berberich Residence 250 Wells Road, Laurel,NY 11948 I have reviewed the roof structure at the subject address. The structure can support the additional weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 2020-Residential Code of New York State and ASCE7-16 when installed in accordance with the manufacturer's instructions. Roof Section R1 R2 R3 Mean roof height 14ft 14 14 Pitch 22 deg 23 26 Roof Rafter 2x6 2x6 2x6 Rafter spacing 24 cc 24 24 Reflected roof rafter span 8.6 ft 8.4 6.1 Table R802.4.4(1)max allowable 11.9 ft 11.9 11.9 The climactic and load information is below: Ground Wind Live Load, Point CLIMATIC AND Exposure Snow Speed,3 Pnet per Pullout Fastener Type GEOGRAPHICAL DESIGN Category Load,Pg, sec gust, ASCE 7, Load, CRITERIA sf mph psf lb Roof Section R1-R3 B 20 140 39 743 SS 5/16"dia lag bolt, 5"length Weight Distribution Array dead load 2.5 psf Load per attachment 27.2 lb Subject roof has one layer of shingles. Panels mount flush to roof no higher than 6 inches above roof surface. Sincerely, p� NF4y 1H0 William G. Fisher, P.E. Licensed Professional Engineer 1 r �tipSSl�' Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections powered by a ;t� DVO i L - . OCELLS naoffwmrr �� *.,� ,.r.* '�-•TOP BRAND PV- yy., Quality Tefcted •• i � ay+ m f{INOiE 4 "* 2019 www VDEW."' --x ID 40032587 Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area,lower BOS costs,higher power classes,and an efficiency rate of up to 19.5%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with C_.J excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Oz Long-term yield security with Anti LID and Anti PID Technology', ` Hot-Spot Protect and Traceable Quality Tra.QTm. EXTREME WEATHER RATING ( High-tech aluminum alloy frame,certified for high snow ry (5400 Pa)and wind loads(4000 Pa). ® A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY /° Q.ANTUM DUO combines cutting edge cell separation and Innovative wiring with Q ANTUM Technology. 'APT test conditions according to IEC/TS 62804-12015,method B(-1500V,168h) 'See data sheet on rear for further information THE IDEAL SOLUTION FOR: 61nRooftop arrays residential buildings Engineered In Germany OCELLS MECHANICAL SPECIFICATION Format 68.5 x 40 6 x 126 in(Including frame) (1740 x 1030 x 32 mm) sasµ�aomm) 3s o t33omm) 33b3'(83°mm) Weight 43.9 lbs(19 9 kg) Front Cover 013 in(3 2mm)thermally pre-stressed glass ° 'j160�) + with anti-reflection technology 4.DmwnPam°°oin(4smm) s°m° Back Cover Composite film sear(eazmm) Frame Bleck anodized aluminum Cell 6 x 20 monocrystalllne Q ANTUM solar half cells ® 40 0•(3D3°mm) Junction Box 2.09-3 98 x 126-2 36 x 0 59-071in(53-101 x 32-60 x 15-18 mm),Protection class I1367,with bypass diodes 453'(33s0mm) Cable 4mm2 Solar cable,(+)245 3 in(1150 mm),(-)245 31n(1150 mm) L__4 s.O°nee°nam �a Connector Steubli MC4,Hanwha Q CELLS HQC4,Amphenol UTX, + 4kM=Undo (DETMA) Renhe 05-6,Tongling TL-Cable01S,JMTHY JM601,IP68 or �` 1,26'(32 UTAILA 0e30•(16mm) Friends PV2e,IP67 osss(2asmm)IIQ336'(esmm) ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-0 W) Power at MPP' PMPP [W] 330 335 340 345 Short Circuit Current' Iso [A] 10.41 1047 10.52 1058 0 Open Circuit Voltage' Vcc [V] 4015 4041 4066 4092 5 Current at MPP IMPP [A] 991 997 10.02 10.07 Voltage at MPP VMPP [V] 3329 3362 3394 34.25 Efficiency' q [%] 2_184 2187 x19.0 2:19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W] 2470 2507 2545 2582 E Short Circuit Current Is, [A] 839 843 848 852 E Open Circuit Voltage Vcc [V] 3786 3810 3834 3859 C Current at MPP IMPP [A] 7.80 784 789 793 Voltage at MPP VMPP [V] 3166 3197 3227 3257 'Measurement tolerances PMPP±3%,Isc,Vcc t5%at STC 1000W/m',25±2°C,AM 15 according to IEC 60904-3.2800 W/m2,NMOT,spectrum AM 15 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE }—,10o 9'- __T—____r___—_—_---n_—___., D 01 OCflu At least 98%of nominal power during ®IwiRW.wwma A.u�m wmmnw i first year.Thereafter max 0 54% 2 I I I I i degradetionperyear.At least 93 1% c ------ of nominal power up to 10 years At -------------- `z 00 least 85%of nominal power up to Z g3 25 years eo -_r.--___I_____y-----t----- I 0 5 I I I I i cz 4° I I I i i z All data within measurement toleranc- e „ es Full warranties in accordance with 80 soo 400 000 °°a 4000 9 the warranty terms of the Q CELLS IRRADIANCE tWlm•I ro sales organization of your respective o 4 mto m m country svca°,am.:mwmm,4°,a°b lowc�P.o rEARS Typical module performance under low Irradiance conditions In $ comparison to STC conditions(25°C,1000W/m2) 17 TEMPERATURE COEFFICIENTS M Temperature Coefficient of Isc a [%/K] +004 Temperature Coefficient of Voc [%/K] -02 Temperature Coefficient of PMPP y [%/K] -036 Normal Module Operating Temperature NMOT [°F] 109±5 4(43±3°C) 0 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vsrs [V] 1000(IEC)/1000(UL) Safety Class II o N Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 1703 C(IEC)/TYPE 2(UL) Max.Design Load,Push/Pull' [Ibs/ft2j 75(3600Pa)/55(2667Pa) Permitted Module Temperature -40°F up to+181;'r Max.Test Load,Push/Pull' [Ibs/ft2] 113(5400Pa)(84(4000Pa) on Continuous Duty (-40°C up to+85°C) m m 3See Installation Manuel U y QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1703,VIDE Quality Tested,CE-compliant,IEC 61215 2016,IEC 61730 2016, Number of Modules per Pallet 32 ° Application Class ll,U S Patent No 9,893,215(solar cells) Number of Pallets per 53'Trailer 28 ® Number of Pallets per 40'HC-Container 24 2 OVE C E Us Pallet Dimensions(Lx WXH) 715 x 45 3 x 48 0 in(1815 x 1150 x 12 2 0 rn Pallet Weight 1505 lbs(683 kg) n Note:Installation Instructions must be followed See the installation and operating manual or contact our technical service department for further Information on approved installation and use of this product Hanwha Q CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL InquiryQus q-cells com I WEB www.q-cells us _ t Data Sheet Enphase Microinverters Region,AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro' 7 and M 7+ dramatically simplify the installation process while achieving the highest system efficiency. a crommars Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy, Enphase IQ Battery",and the Enphase Enlighten T" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class If double-insulated enclosure • UL listed 1270 Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U *The IQ 7+Micro is required to support 72-cell modules To learn more about Enphase offerings,visit enphase.com %=�O Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings, 295W-350W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 121 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5 8 Arms Maximum units per 20 A(L-L)branch circuit" 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading. 0.7 lagging 0.7 leading..0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 976% 97.5% 97.3% CEC weighted efficiency 970% 97.0% 97.0% 970% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-8-US&IQ7PLUS-72-B-US) Friends PV2(MC4 mtermateable). Adaptors for modules with MC4 or UTX connectors. PV2 to MC4:order ECA-S20-S22 PV2 to UTX.order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30 2 mm(without bracket) Weight 1 08 kg(2 38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and bC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C222 NO 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1 No enforced DC/AC ratio See the compatibility calculator at htips//enphase,comlen-us/support/module-compatibility 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary Refer to local requirements to define the number of micromverters per branch in your area To learn more about Enphase offerings,visit enphase.com EN PHAS Ee ©2018 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc 2018-05-24 •A IRONRIDGE Roof Mount System 1 i, :..._ ,i Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior " Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Software Certified to maintain the fire resistance HEMOnline tool generates a complete bill of rating9"' of the existing roof. materials in minutes. g Integrated Grounding 20 Year Warranty UL 2703 system eliminates separate .° Twice the protection offered by , a, module grounding components. competitors. m --� XR Rails ....._.� XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail, rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability - 12'spanning capability • Self-tapping screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear& black anod.finish • Clear& black anod.finish • Clear anodized finish • Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs Anchor, flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face • Works with vent flashing Attaches directly to rail • IBC& IRC compliant Heavy-duty profile shape • Ships pre-assembled Ships with all hardware • Certified with XR Rails • Clear& black anod.finish • 4"and 7"Lengths Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps O T Bolt Grounding Lugs d Accessories ULim&t Y ` .r< Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish &black anod. Parallel bonding T bolt • Easy top-slot mounting • Snap-in Wire Clips • Sizes from 1.22"to 2.3" Reusable up to 10 times • Eliminates pre-drilling • Perfected End Caps • Optional Under Clamps Mill & black stainless • Swivels in any direction • UV-protected polymer Free Resources Design Assistant A NABCEP Certified Training --_ • Go from rough layout to fully ®017 Earn free continuing education credits, engineered system. For free. d t- while learning more about our systems. _ Go to lronRidge.com/rm V Go to IronRidge.com/training 1� AERIAL "`'{'Long Island °o° P®WEIR SOLUTIONS I�-3 2060 OCEAN AVUE # MODULES (5) ®3`- i_wh ��''� ' "` RONKONKOMA, NY 11779 rt.rt,}'�. -"• "R (631)348-0001 PITCH: 26 . =�' (,- i 71 AZIMUTH- 3460 " BERBERICH RESIDENCE 250 WELLS ROAD r LAUREL NY 11948 CCESS ��:r h_�: _ _ -• .�, �; �� � :'.- , / M 631-871-0235 Y uy 3 S: 126 B: 6 L: 6 /ro .�, fa.rs> �R «_ t 6,•_ry,-� _ - _ - ',y'`" PROJECT DATA: #214476 INVERTER. (23)ENPHASE IQ7-60.2-US y MODULES (23)Q.PEAK DUO BLK-G6+340 _" t l` :. Y a;'' -�i• { RACKING: IRON RIDGE XR100 WATTAGE 7,820 SHEET INDEX ROOFTYPE: COMPOSITION SHINGLES /,TIA'// p-2 WIND LOAD -39PSF @ 140MPH ��ESSPAT" i f\ S-1 SITE PLAN FASTENER USE 5/16"DIA.5"LAGS # MODULES (9_) S-2 DETAILS L, ` - PITCH: 23° E-1 ELECTRICAL PLAN `° - . ° L-1 MOUNTING PLAN � ° • ;. AZIMUTH: 77 z " # MODULES (9) / -!!197PITCH: 22° ` E2 � � � 4 �r ��� z AZIMUTH: 257° ' # 0 N O N O m�. �GENERAL NOTES c ul -ENPHASE IQ7 MICRO INVERTER LOCATED ON QE ROOF BEHIND EACH MODULE. O -FIRST RESPONDER ACCESS MAINTAINED co)- —n / AND FROM ADJACENT ROOF. _ -WIRE RUN FROM ARRAY TO CONNECTION IS / 40 FEET. / -COGEN DISCONNECT IS LOCATED C:i // / 9 31_5511 ADJACENT TO UTILITY METER. (.n / M 1d/�°d" / w _ -LAYOUT SUBJECT TO CHANGE BASED ON ALTERATION LICENSED TIES MEESDOCUTEXCEPTBYA SITE CONDITIONS AT DATE OF INSTALL � —911 51 - PAPER SIZE 11"x 17°(ANSI B) JLEGEND DATE: 05/04/2021 w DESIGN BY: EE 42 c ® GROUND ACCESS POINT CHECKED BY:MW xi N COGEN DISCONNECT REVISIONS: m ® UTILITY METER 3 REPRESENTS ALL FIRE CLEARANCE FIRST RESPONDER ACCESS 2020 RESIDENTIAL CODE OF NEWYORK STATE,2020 ENERGY CONSERVATION CODE OF NEWYORK STATE, INCLUDING ALTERNATIVE METHODS MINIMUM OF 36 UNOBSTRUCTED AS PER TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE740. SITE PLAN S- 1 U THE 2020 RESIDENTIAL CODE OF NYS IronRidge X-R 1.00 Rail F Long Island ILI (tom POWER SOLUTIONS - Y 2060 OCEAN AVENUE, RONKONKO MA, NY 11779 (631)348-0001 _ _- - RICH - r BERBE- Cap RESIDENCE Flashing 250 WELLS ROAD LAUREL, NY 11948 631-871-0235 End _L -loaf S: 126 B: 6 L: 6 IlonRidge XR 100 Rail" - '' �----�`- '` °' x 5" Stainless PROJECT DATA: #214476 SI16 11ronRidge XR 100 Rail INVERTER (23)ENPHASE IQ7 60 2-US Steel Lag Bolt MODULES (23)Q.PEAK DUO BLK-G6+340 Solar Module RACKING IRON RIDGEXR100 WATTAGE 7,820 3/8�1 G x Z/4Hl X HEAD @3�T ROOF TYPE COMPOSITION SHINGLES 3/i'8-9'6 FLANGE NUT ^ _�/(8 t' WIND LOAD -39PSF @ 140MPH 3 FASTENER USE 5/16"DIA.5"LAGS U m U LU n U � N O w >-m 1n U J�P'o L W- �y� r wku �Inz_ Z to�t"o Z W w U, U) GENERAL NOTES: N -L FEET ARE SECURED TO ROOF RAFTERS @ 72" O.C. USING 5/16" x 5" STAINLESS STEEL LAG BOLTS. o� N -SUBJECT ROOF HAS ONE LAYER. ��� °�' c. �0 -ALL PENETRATIONS ARE SEALED AND FLASHED. p . ROOF PITCH RIDGE RAFTERS LENGTH OVERHANG NOTES �J7'4659�. � AR1 220 2"x621X6" 24"O.C. 13'-711 4R LICENSED PROFESSIONAL ISILLEGALu V O 11 11 11 11 11 1 �]1-611 4�11 PAPER SIZE 11°x 17°(ANSI B) N J d R2 23 2x6 2x6 @24 O.C. � DATE: 05/04/2021 DESIGN BY: EE ca ca R3 260 2"x6°' 2"x6"@24"O.C. 7'-11 " 11 " CHECKED BY:MW REVISIONS: U N N m DESIGNED AS PER ASCE 7-10 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, MODULES MOUNTED FLUSH TO ROOF TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE740. DETAILS - NO HIGHER THAN 6"ABOVE ROOF SURFACE Long Island ejo POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 491-611 11 BERBERICH 23 -7 \ \ \ \ RESIDENCE 7'_11 LAUREL, NY 11948 131_711 t _ - 631-871-0235 S: 126 B: 6 L: 6 I f" VW-W77=1 _ s _ PROJECT DATA: #214476 INVERTER- (23)ENPHASE IQ7-60-2-US 3 MODULES- (23)Q PEAK DUO BLK-G6+340 # MODULES (5) RACKING IRON RIDGE XR100 WATTAGE 7,820 R-1 PITCH: 260 ROOF TYPE COMPOSITION SHINGLES WIND LOAD: -39PSF @ 140MPH # MODULES (9) AZIMUTH: 346' FASTENER USE 5/16"DIA.5"LAGS LO PITCH: 22° � 0 AZIMUTH: 257° � ° W Zo=� LO In 491_611 z t J z z t a w 0 N 3 o 13 6 t OF *C�j `P\\�q&m G.F 11 14 R-2 � 7 O ALTERATION OF THIS DOCUMENT EXCEPT BY A r- 4� # MODULES (9) LICENSED PROFESSIONAL IS ILLEGAL 0 ^1_611 PAPER SIZE 11"x 17°(ANSI B) v vK CD ® SPLICE BAR 14 PITCH: 23 o DATE: 05/04/2021 w © PENETRATIONS 600 DESIGN BY: EE AZIMUTH: 77 CHECKED BY:MW UFO 60 CJ�_911 REVISIONS: 40MM SLEEVE 28 END CAPS 28 tmN CONSUMPTION o CRITTER GUARD 175' MOUNTING PLAN L— 1 PHOTOVOLTAICS: ` Long Island a °o (23) Q.PEAK DUO BLK-G6+ 340 ( POWER SOLUTcIONS NEMA 3R 2060 OCEAN AVENUE, JUNCTION BOX INVERTERS: RONKONKOMA, NY 11779 (631)348-0001 BLACK-L1 ENGAGE CABLE (23) ENPHASE IQ7-60-2-US RED- L2 BERBERICH WHITE-NEUTRAL CIRCUITS: GREEN-GROUND (1) CIRCUIT OF (11) MODULES i (1) CIRCUIT OF (12) MODULES RESIDENCE 250 WELLS ROAD LAUREL, NY 11948 631-871-0235 S: 126 B: 6 L: 6 PROJECT DATA: #214476 INVERTER (23)ENPHASE IQ7.60-2-US #12 AWG THWN FOR HOME RUNS UNDER 100' I MODULES' (23)Q.PEAK DUO BLK-G6+340 #10 AWG THWN FOR HOME RUNS OVER 100' (1)LINE 1 r _ _ _ c RACKING: IRON RIDGE XR100 (1)LINE 2 WATTAGE 7,820 I I a (1)NEUTRAL METER ROOF TYPE COMPOSITION SHINGLES (1)GROUND WIND LOAD. -39PSF @ 140MPH PER CIRCUIT I I b L 23 FASTENER' USE 5116"DIA 5"LAGS IN 1"OR 14 PVC CONDUIT i !- Tj . j I a , Ln © ® ` 1 "o PHOTOVOLTAIC W Zona, MAIN SOLAR SYSTEM Lu J I f AC DISCONNECT Z Nom Eno LINE SIDE TAP w Z m �D tL i ( w I = 60A FUSED SERVICE MAIN SERVICE 125A LOAD CENTER I� — RATED DISCONNECT 150A OF N (1)-20A BREAKER �---� 30A FUSE —� �Q °m �'���" - — O PER CIRCUIT IN` DISCONNECT INVERTFIR OUTPUT CONNECTION � DO NOT RELOCATE THIS #8 AWG THWN #6 AWG THWN OVERaOURRE:NT DEViCE (1)LINE 1 (1)LINE 1 .a 1 (1)LINE 2 (1)LINE 2 3 (1)NEUTRAL (1)NEUTRAL D AC DISTRIBUTION PANEL EGC ALTERATION OF THIS DOCUMENT EXCEPT BYA LICENSED PROFESSIONAL IS ILLEGAL (1)GEC OR SUB PANEL PAPER SIZE 11"x 17°(ANSI e) IN 14'PVC CONDUIT ( ) N IN 17'PVC CONDUIT ; DATE: 05/04/2021 DESIGN BY: EE =-- — CHECKED BY:MW U — REVISIONS: N a N 0] N AC COMBINER: NOTE: 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, 1—PHASE,MAIN LUG LOAD CENTER, 125A ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE74 0. ELECTRICAL PLAN ° 60A FUSED SERVICE RATED DISCONNECT E- 1