HomeMy WebLinkAbout46444-Z �o�Os lTown of Southold 7/27/2021 & o y� P.O.Box 1179 co z 53095 Main Rd GSouthold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42197 Date: 7/27/2021 THIS CERTIFIES that the building GENERATOR Location of Property: 7630 Main Bayview Rd., Southold SCTM#: 473889 Sec/Block/Lot: 87.-5-16.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 6/7/2021 pursuant to which Building Permit No. 46444 dated 6/18/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessorygenerator as applied for. The certificate is issued to Calcaterra,Regina&Ciaravino,Todd of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46444 6/21/2021 PLUMBERS CERTIFICATION DATED 0 R ( LIN t ori d Signature o�SUFFoi��o TOWN OF SOUTHOLD aye BUILDING DEPARTMENT C* z TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46444 Date: 6/18/2021 Permission is hereby granted to: Calcaterra, Regina 250 Oak Rd New Suffolk, NY 11956 To: install generator as applied for. At premises located at: 7630 Main Bayview Rd., Southold SCTM # 473889 Sec/Block/Lot# 87.-5-16.1 Pursuant to application dated 6/7/2021 and approved by the Building Inspector. To expire on 12/18/2022. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CO-ALTERATION TO DWELLING $50.00 Total: $235.00 Bui ing Inspector rjv so Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 ® �� sean.devlinCcD-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Regina Calcaterra Address: 7630 Main Bayview Rd city:Southold st: NY zip: 11971 Building Permit#: 46444 Section: $7 Block 5 Lot: 16.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Mariner Electric License No: 45056ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor X Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transfer Switch 200A UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 12kW Briggs and Stratton Generator w/200A Whole House Transfer Switch Notes: Generator Inspector Signature: L�� - Date: June 21, 2021 S Devlin-Cert Electrical Compliance Form.xls # # TOWN OF SOUTHOLD BUILDING DEPT. `ycourmeF'' 765-1802 = INSPE=CTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND - - [ ] INSULATION/CAU KING [ ] FRAMING /STRAPPING [ FINAL&I [ ]-'FIREPLACE &CHIMNEY - [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) �C y -------------------------------- FOUNDATION(2ND) S O ROUGH FRAMING& y PLUMBING INSULATION PER N.Y. y STATE ENERGY CODE FINAL AD ITIONAL COMMENTS u n to-a � L K m � y H d b H SUFFoc�• �, TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone 631 765-1802 Fax 631 765-9502 https://www.southoldtowm.gov Date Received APPLICATION BUILDING PERMIT For Office Use Only i l ; lL, PERMIT N0. Building Inspector: a UN 202 J _ 7 Applications and forms must be filled'out in their entirety.incomplete applications will not be accepted. Where the Applicant is not the owner;an -f';E7,V Cy Owner's Authorization form(Page 2)shall be completed. 'r Date:4/1/2021 OWNER(S)OF PROPERTY: . Name:Regina Calcaterra 7s7 #1000- �7 Project Address:7630 Main Bayview Road Southold 11971 Phone#:631-903-0031, Email:rcalcaterra @gmail.com Mailing Address:7630 Main Bayview Road Southold 11971 CONTACT PERSON: 1) Name:,' - �o�e� )< tZveR,t� MailingAddress:P.O BOX: 512 Cutchogue Phone#:631-383-8502 JIG-31q- '7/ q / Email:peconicpowersys@gmail.com DESIGN PROFESSIONAL INFORMATION: Name: Mailing Address: Phone M Email: 'CONTRACTOR INFORMATION:' , Name:Peconic Power Systems LLC Mailing Address:P.0 Box: 512 Cutchogue Phone#:631-734-5026 Email:peconicpowersys@gmail.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: 20ther Generator $6,000.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 w, INFORMATION"Q ez Existing use of property:Residential Intended use of property:Residential Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? E]Yes El No IF YES, PROVIDE A COPY. W, al, 4-M L'10 Checlklk ftilftidingti4he ow�ontracthr/desfr 16r'tal'is*r6ip6nslh1e for,all,orainage a n&si& ater ed M- `� '�1 5"Chbpter,236 of thd;4N"Code. APPLICATION ISMEREBY MAta.t, Building Department'for the,, of a Buikl t'peirtnit pu uIll O!dinagce of tfi6,Tdwn`6f Southold,Suffolk,covAiV,New Y rk-apO el;,appllcable Laws,Ordi"—R gekorRegulation' nstr 11 Ing o _otO� ,A#o -qnvalterttions or for rernovoloeJernall' as he applicant agreed tb co ywith all applicableor Inafkis;bulld hi 6j�j'c6de an'd6e6i6lationsand' lap cessary in a s madeherem ir'i ptiriisiiable to admit authorized piernises and'in fiulldjnj(s),�fp�,ne "--4- Ne York saciass' ihisdemeanorpursti�r-ii'�iisectI he w of Sta eI Robert Stanevich Application Submitted By(pri t name): I@Authorized Agent ElOwner Signature of Ap !cant: Date: May 24, 2021 -------------- I A STATE OF NEW YORK) SS: COUNTY OF Suffolk Robert Stanevich being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, Contractor (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 24th May 21 day of 20 r%A I ki, L L�-- Notary Public;S\ L ,—,- 4 1>1 STATE \,o � / OFNEW YORK PROPERTY OWNER AUTHORIZATION NOTARY PUBUG I (Where the applicant is not the owner) 02CM40W17 0, 0 N Regina Calcaterra 7630 Main Bayview Rd., Southold, residing at Robert Stavenich do hereby authorize to apply on my Wif to the Town of South o 14.&u4ki ng Department for approval as described herein. May 24, 2021 OXer-'-s Signature Date Regina Calcaterra Print Owner's Name 2 r� �I�l, BUILDING DEPARTMENT- Electrical s ector_—L I TOWN OF SOUTHOLD.; i o _ Town Hall Annex - 54375 Main Road - PO PA 11192021 C** - Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631 7G' bY02' rogerr(c�southoldtownny.gov seand(a,soufh'oldto'wniil APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date.- Company ate:Company Name: Pecoa,c, awe S Name: 0604_ ' License No.: A fir_ L�(o�Cg email: Address: Po pkx Sl Phone No.: 631 _ -73L/ - -5-0 0-6 JOB SITE INFORMATION (All Information Required) Name- Q,� e-% C.,1 cId-ur Address: 14"'30 v, 4.4 Cross Street: Phone No.: 3) s qo S - bo 9) Bldg.Permit#: q� q(4 email: Tax Map District: 1000 Section: Block: cj Lot: ' BRIEF DESCRIPTION OF WORK (Please Print Clearly) 101 Circle All That Apply: Is job ready for inspection?: (M�/ NO Rough In Final Do you need a Temp Certificate?: YES / Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect - Flood Reconnect - Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form As PERMIT# Address: W Switches Outlets G FI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Tra nsfe r AC AH Mini Special: Comments G u�' sieraueA� e.—ou aerrsvaNu.,nNosuix renr.a nu1-so eeavEo ° D O O C ✓ .1: u� Nen oomeN�rNe�a� �aN� �e� b�a�eaa�, �aweu oNe.,emoN„ne��, N�oFN� .max �Z m 'IOU, o V Z.- ea��e�s,��e .�ex�,NeTx�.NneeaxE��on�o»x�,�nneo�W�uweax.,.emw,eN P� 3 C Y �I } yu=aN�eee�NORn.exxe�TNn.e„Mr> .T �N,Pw�xa�.a®,x x�wm �Nxae e�,a�ro�e�.am�reauN�,eaeT� m O 2 I V 1 r N O _jjy _ ,� ac.u+merT.Qxnv>onxsr.>enssowr,oNo..ao�oN.,..ww wmm,e.oaa iNe.raeumFue..noN,sw,rcopu�anoxsronv.No..,NEooexoue.eonverna�s D 9T' O (n a«/Lr�rro` e�Ne�mO.cn�oe AE w°Txw�s "�u�eH�. �T�r��ae no���oN a Na�. . Q m m> z O O0-1 1m Z Z 1�!. _ l��+- ”- 4 e, nwMr � �°o`.a°c o�.aaove>+rxrsoao.eao.cN.,o.rs.weNoruwn�re�,owNnrmovrzr.Nus>orrzn�.�o a..xrox.:a,�.T.nuw.aow,.�rrsw. IA ° 000 T1 1' rn m a. of cy w.xe wao�NeNso.�cao.�NDrenaENCTeore.Nnxea n �I DQ O 0 ,�g � >n�o�e 3,oao n, ox,s owxN�ex ao �s a a®o xE.ao.�m.. gnat,.soenr,c,oa�oeenxoc:eANo N�oacMeNOT N eNo�w D zzg N y^3i ` +; ^,� ,N<cxecnoNor.cxcrs aernixwcwnus rooms.xTw�w,N,e.e,u,eu.oomoxsroeunoe,csw�nN>o,>,eaTr.eorcoxe„x,�,-eN r -4 $o m'n N O N 0 r m q y�ij #t7 e.aaPee ;"m�`�..xb>ee,xwoTNewm:amrcanSNvnone eossmszasNa NOTeecowio�mo>ooe,�woco.T m �Q r m e m o C O �qq o xN sWeaeNOTSeT�.moF msUmeTUN�caOT„�MseNO m z> i 0 D m `a -Z{{ "0 I'1 ° i Z mCm +CAZ-m zip Cm = ZW `.p. o N N N +a o_ C' A N N2Nr�° m N D m A O Z � � _ — roNNWH G> F G"�' O N °";n?I"',+Nim [7 m O tt g I _ Zz OU Z G) m 0�• `0 r Nr ! O: 0 �Z LAND N/F MARIA MATTHEW&MANFRE ZAND E f .° I .ti N25°56`50"E 32 ,22 " LAND N/F EILEEN&GARY ZAKARIN f Nc 1 Or ryGr PIPePHD. mon FHw I ro moH.PHa o-c m N2N24°22'50"E 150.06 Ile U) /0 1 m m p m a 8 V $ �2sR i D _ xa a FRAME RES i � y #7630 L J O D � m D�ovepo�HCC h > m G V i O N <vsg0 � - cava onlvEwwv _ _�___ N O 490.00 ASPHALT DHN6WAY 30' WIDE PRIVATE RIGHT OF WAY � LAND N/F ANTHONY DANIELE C\Users\Owner\0ne0rNe\AJC\7630 moin boyvmw rd soulhold dwg(new fox lot 16 1)Lost Modified Jul 31 2020 Plolled by AJC 1 DATE(MMIDONYYY) AC R® CERTIFICATE ®F LIABILITY INSURANCEF 02/11/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the pollcy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Josh Mitchell Freedom Coverage Corp PHONE o".t: (631)709-2777 FAX No; 80 Orville Dr Suite 100 A -MA ESS: Josh@FreedomCoverageNY.com Bohemia, NY 11716 INSURERS AFFORDING COVERAGE NAIC e INSURER A: Utica First Insurance Company 15326 INSURED INSURERS: Employers Insurance 11512 Peconic Power Systems LLC INSURER C: 315 Commerce Rd INSURER D: Cutchogue, NY 11935 INSURERE: INSURER F: COVERAGES CERTIFICATE NUMBER: 00000166.42889 REVISION NUMBER: -3 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. /NSR TYPE OF INSURANCE ADDL UB POLICY NUMBER POLICY EFF POIDDY EXPLTR rrrm LIMITS A X COMMERCIAL GENERAL LIABILITY ART5152101-00 12103/2020 12/0312021 EACH OCCURRENCE $ 1,000,000 CLAIMS MADE DAMAGE TO N D OCCUR PREMISES Ea rrence $ 50,000 MED EXP(Any one person) $ 5,000 PERSONAL S ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $ 2,000,000 �( POLICY jE a LOC PRODUCTS-COMPIOP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBIN D SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident) UMBRELLA UAB HOCCUR EACH OCCURRENCE $ EXCESS/JAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ B WORKERS COMPENSATIONOTH- AND EMPLOYERS'LIABILITY EIG4706645 02/03/2021 02/0312022 STATU X ER ANY PROPRIETORIPARTNER/EXECUTIVE YINI E L.EACH ACCIDENT $ 1,000,000 OFFICERIMEMBER EXCLUDED? N/A (Mandatory In NH) EL DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below EL.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) As pertains to insureds operations CERTIFICATE HOLDER CANCELLATION Town of Southhold- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. Town Bali Annex 54375 Main Road P.O. Box 1179 AUTHORIZED REPRESENTATIVE Southold, NY 11971 i'a JCM ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Printed by JCM on February 11,2021 at 11:20AM r APPROVED AS NOTED L� DATE: U B.P.# r FEE: BY: NOTIFY„BUILDING CEPARTME T - 765-1802'- 8 AM TO 4 PM FOR THE �+ p FOLLOWING,INSPECTIONS: OCCUPANCY OR 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE USE IS, UNLAWFUL 2. ROUGH - FRAMING & PLUMBING 3. INSULATION WITHOUT CERTIFICATE 4. FINAL - CONSTRUC7;nN MUST OF OCCUPANCY BE COMPLETE O. ALL CONSTRUCTION SLiALL MEET THE REQUIREMENTS OF'THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES ELECTRICAL AS REQUIRED AND CONDITIONS OF INSPECTION REQUIRED �r ni t N ZBA BOARD --S ffff -D-TM TRUSTEES Standby Generator �SRIGGS&STRA►TTOIV � � Briggs & Stratton® The Smart Choice Reliable back-up power for-added peace of mind. Guard against losses due to power outages with a Briggs & Stratton Standby Generator. 0 Parts•Labor-Travel Limited CuL oS Warranty' LISTED-- New Upgraded Control System Charging System • New AVR optimizes generator performance with tighter voltage control Independent battery charger • LCD display that displays multi-line text and graphics • Optimizes battery life with a 3-stage battery charger(bulk, • Default exercise cycle setting of 16 seconds absorption,and float stage) • Low speed exercise available to save fuel and reduce noise Corrosion Resistant Enclosure& Base • Monitors cold temperatures to avoid moisture buildup in engine oil • Cleaner power with improved frequency regulation Made with automotive grade galvanneal steel to resist rust • More efficient alternator capable of starting most 5-ton air conditioners Powder-coated paint for years of protection against chips and abrasions Designed for Easy Installation & Maintenance Certified to withstand hurricane-force winds up to 175mph5 • Approved for installation as close as 18"to a building' Briggs&Stratton®Full Synthetic Generator Oil • Removable roof and side panels provide better service access to the engine and alternator Shields the engine from low temperature sludge buildup • Controller,battery charger,and AVR can be replaced separately and high temperature deposits • External on/off switch located on back of enclosure Reduces engine wear,scoring and abrasion Commercial Vanguard®Engine Compatible with Symphony®II Power Management System - Easy conversion between natural gas(NG)and liquid propane vapor (LPV)during installation Customizable to your home's needs • Advanced debris management keeping engine clean and cool for • Automatically balances the power of your home's electrical load enhanced durability and performance including high wattage items like air conditioning units and • Dynamically balanced crankshaft minimizes engine noise and vibration electric ovens • Offers whole house power with a more affordable home generator • Compatible transfer switches and modules sold separately Generator Set Rating, Liquid Propane Vapor Natural Gas Limited Warranty' Model Enclosure Voltage Phase' Hz Circuit LPV kW LPV Amps NGkW` NG Amps Parts,Labor,Travel Type Breaker Amps 040590 Steel 120/240 1 60 60 12 50 10.8 45 5 Year This generator is certified in accordance with UL(Underwriters Laboratones)2200(stationary engine generator assemblies)and CSA(Canadian Standards Association)standard C22.2 No.100-14(motors and generators). 'The installation manual contains specific instructions related to generator placement in addition to NFPA 37,including the requirement that carbon monoxide detectors be installed and maintained in your home. 3 Single phase units are rated at 10 power factor and three phase units are rated at 0 8 power factor. See operator's manual or BRIGGSandSTRATTON.com for complete warranty details. s Up to 175 mph,when installed in accordance with the installation manual. 1 BR G. N" 12kW' Standby Generator Engine Specifications Engine Lubrication Engine Brand Vanguard Oil Capacity(L qt) 1.3/1.37 Engine Speed(RPM) 3600 Low Pressure Switch, Included Engine Fuel Liquid Propane Vapor(LPV)or Lubrication System Full Pressure Natural Gas(NG) Engine Cylinder Configuration OHV Oil Briggs&Stratton 5W30 Full Synthetic Number of Cylinders 2 FAlteinatolrl Specs Displacement(L/Ci) 0.627/38.26 Manufacturer Mecc Alte Compression Ratio 8.3:1 Type Self-Excited,4-Lead Governor Type Electronic Voltage Regulator Automatic Frequency Regulation +/-0.3 Hz(0.5%) Insulation Class H Valves OHV with Hardened Seats Peak Motor Starting WA 37 Fixed Timing Magnetron® I'Colit'roller Features Ignition System Electric Ignition i Starter Motor Rating Voltage 12 Volt Generator Sensing Single phase voltage monitoring Battery Required 12 Volt,Group BCI 26 or 51, LCD Display Displays multi-line text and graphics 540 CCA Minimum High Temperature Switch Included Fault Display Provides up to 39 detailed fault codes Dura-Bore Cast IronSix exercise length options Cylinder Sleeve Included Exercise Cycle Default:Start and run for 16 seconds; Abort exercise below 40°F(internal temperature) Operations Fuel Consumption? i Sound Ratina AtTMeters Full Load 1/2 Load No Load Low Idle Mode 64 dBA 4 BTU/hr NG-172,000 NG-117,000 NG-66,000 No Load 69 dBA 4 LPV-209,000 LPV-155,000 LPV-57,000 NG-171.6 NG-116.9 NG-66 ft3/hr LPV-83.3 LPV-61.8 LPV-22.6 NG-4.87 NG-3.31 NG-1.87 m'/hr LPV-2.37 LPV-1.76 LPV-0.65 g/hr LPV-2.26 LPV-1.68 LPV-0.62 57 Parts-Labor-Travel Unlike some other standby generator manufacturers, our warranty covers parts, labor AND travel Limited Warranty' for the full length of the warranty with no start-up costs! This generator is certified in accordance with UL(Underwriters Laboratories)2200(stationary engine generator assemblies)and CSA(Canadian Standards Association)standard C22.2 No 100-14(motors and generators). 2 Fuel consumption rates are estimated based on normal operating conditions at load.Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances-fuel flow rates may vary depending on these factors See operator's manual or BRIGGSandSTRATTON com for complete warranty details. 2 BRIGGS6srRAiTON 12W Standby Generator Additional r r Operations 41 Certifications Engine Warm Up(sec) 20 seconds after all settable delays CARB Compliant* Engine Cool Down(min) 5 FCC Part 15 Class B/CAN ICES-003(B) Response Time(sec) Immediate after engine warm up I cUL Listed to CSA 22.2 No.100-14 Weight and Dimensions J UL2200Listed Assembled Weight(Ibs/kg) 361/164 Overall Dimensions(in/mm) 28 x 26.1 x 37.2/711 x 663 x 945 EPA Certified Fuel System Packaged Weight(Ibs/kg) 423/192 Complies with NFPA 374.1.4.1.2 Packaged Dimensions(in/mm) 39 x 33.5 x 45/991 x 851 x 1143 Avallae Accessories Enclosure Material Galvanneal Steel with Corrosion Maintenance Kit 6035 Resistant Paint Cold Weather Kit 6567 Available Transfer Switches E-Stop Kit 6491 071100 100 Amp Power Management 071052,071053 071150 150 Amp Low Voltage Module Power Management 071051 071200 200 Amp High Voltage Module 071071 Symphony°11100 Amp Generator Status LED Kit 6535 071070 Symphony®If 150 Amp Battery Warmer 6578 071068 Symphony®11200 Amp InfoHub Universal 6574 071057 Symphony®II Dual 200 Amp 28 in(711 mm) 26.1 in(663 mm) 37.21n (945 mm) • 26.1 In(663 mm)- 22.5 In(572 mm) CARB does not regulate emergency standby generators outputting less than 50 HP.Only the EPA standards apply. 'This generator is certified in accordance with UL(Underwriters Laboratories)2200(stationary engine generator assemblies)and CSA(Canadian Standards Association)standard C22.2 No.100-14(motors and generators). 3