Loading...
HomeMy WebLinkAbout46153-Z guFF�� � O l'pG Town of Southold 7/18/2021 P.O.Box 1179 o �4 o _ 53095 Main Rd �4 �o + Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42174 Date: 7/18/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 475 Pinewood Rd.,Cutchogue SCTM#: 473889 Sec/Block/Lot: 110.-3-5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/8/2021 pursuant to which Building Permit No. 46153 dated 4/27/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels at existing singley dwelling as applied for. The certificate is issued to P'Simer,Christine&Cooper,Clare of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 46153 5/25/2021 PLUMBERS CERTIFICATION DATED t or' e Signature o�SufEet�co TOWN OF SOUTHOLD BUILDING DEPARTMENT H TOWN CLERK'S OFFICE oy � SOUTHOLD, NY Ol `A**r4 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 46153 Date: 4/27/2021 Permission is hereby granted to: P'Simer, Christine 475 Pinewood Rd Cutchogue, NY 11935 To: Install roof mounted solar panels at existing residence as applied for. At premises located at: 475 Pinewood Rd., Cutchogue SCTM # 473889 Sec/Block/Lot# 110.-3-5 Pursuant to application dated 4/8/2021 and approved by the Building Inspector. To expire on 10/27/2022. Fees: SOLAR PANELS $50.00 CO-ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 "—�A Building Inspector oF so - Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® sean.devlin(cD-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Christine P'Simer Address: 475 Pinewood Rd city Cutchogue st: NY zip: 11935 Building Permit#. 46153 Section 110 Block. 3 Lot: 5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Long Island Powe Solutions License No: 36178ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect 34A Switches 4'LED Exit Fixtures Pump Other Equipment: 11.56kW PV Solar Energy System w/ (34) 340W Modules , Enphase IQ Combiner 3 w/220x3 210x1, AC Disconnect 34A Notes: Solar Inspector Signature: Date: May 25, 2021 S. Devlin-Cert Electrical Compliance Form As -- -- - ----- o��OF SOblyo � 1L✓ � S3 -- � 7 S �r -- - - - ----- ---- # TOWN OF SOUTHOLD BUILDING DEPT. G _ 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE INSPECTOR ��-- S0UTq � Wwoo kA6, # TOWN OF SOUTHOLD BUIL ING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAAULKING [ ] FRAMING/STRAPPING [ FINAL So[4V'-.- [ ] FIREPLACE & CHIMNEY [' ] FIRE SAFETY-INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: N 0 Cl #4A - q DATE INSPECTOR L�6 t 5 Fisher Engineering Services, P.C. 509 Sayville Blvd - Sayville •New York 11782 Phone: (631) 786-4419 '�I� �F n June 18, 2021 E V JUL - 6 2021 Southold Building Department 54375 NY-25 EUMDING DEPT. Southold,NY 11971 T0Be71 C''.?d,r,1�rTTTOLD Subject: Solar Energy Installation for P'Simer Residence-475 Pinewood Road, Cutchogue,NY 11935 Fisher Engineering Services, P.C. has reviewed the solar energy installation at the subject address onVlayrl5;202'l. The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawings. The installation meets the requirements of the 2020 Residential Code of New York State, 2018 International Residential Code (2018 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2017, and the provisions of ASCE 7-16. To the best of my knowledge,the work summarized in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice, with the view to the safeguarding of life,health,property and public welfare. NE Regards, t°►� r William G. Fisher,P.E. Licensed Professional Engineer .q [3 L Architectural Design•Residential•Light Commercial I a Additions•Extensions•Conversions 43' Construction Estimates/Oversight•Expediting•Inspections } j R� FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) -------------------- -- ` ;�. ai FOUNDATION(2ND) ROUGH FRAMING& r H PLUMBING 9 r r� H INSULATION PER N.Y. STATE ENERGY CODE 6S FINAL ADDITIONAL COMMENTS o z rn , ' H z x LJ I TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 y � Telephone(631) 765-1802 Fax(631) 765-9502 https://www.southoldtownny_gov Date Received PPUCAMN FOR BULONG FERN Up� e 1 1- For Office Use Only PERMIT NO. 'q("v!5 Building Inspector: APR $ 2021 Applications and forms must be filled out in their entirety. Incomplete, applications will not be accepted. Where the Applicant is not the,owner,an Owner's Authorization form(Page 2)shall be completed. Date:2/22/21 OWNER(S)OF PROPERTY: Name:Christine P'Simer TSCTM#1000-110-3-5 Physical Address:475 Pinewood Road, Cutchogue,NY 11935 Phone#:516-567-0179 Email:cpsimer@comcast.net Mailing Address:475 Pinewood Road, Cutchogue, NY 11935 CONTACT PERSON: Name:Sue Estabrooke/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:sue@longislandpowersolutions.com DESIGN PROFESSIONAL INFORMATION: Name:Fisher Engineering Services, P.C. Mailing Address:509 Sayville Blvd., Sayville, NY 11782 Phone#:631-786-4419 Email:bill@fisher-ny.com CONTRACTOR INFORMATION: Name:Michael Catizone/Long Island Power Solutions Mailing Address:2060 Ocean Ave., Ronkonkoma, NY 11779 Phone#:631-348-0001 Email:mike@longislandpowersolutions.com DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition ®Alteration ❑Repair ❑Demolition Estimated Cost of Project: ®Other Proposed(34)panel roof mounted array. (11.560)kW System. $22,940.00 Will the lot be re-graded? ❑Yes ®No Will excess fill be removed from premises? ❑Yes ®No 1 sl PROPERTY INFORMATION Existing use of property:Sin le Famil -Qwqlting Intended use of property:Sin le Famil Dwelling Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to this property? Dyes @No IF YES, PROVIDE A COPY. @ Check Box After Reading: The owner/contractor/design professional is responsible for all drainage and storm'water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized inspectors on premises and in building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Citizone Electrical/Long Island Power Solutions Application Submitted By(print nam ): @Authorized Ag nt ❑Owner Signature of Applicant: �6 Date: STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Michael Catizone being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this day of 201ml- Notary Public LYNDE SUSETTE ESTABROOKE PROPERTY ®V1/IVER AUTFI®RIZAT9® OTARY PUBLIC,STATE OF NEW YO K (Where the applicant is not the owner) Registration No.-OIES6259997,, Qualified i&0At'chess,County Commission Expires April 16,202 residing at \ �C Michael Catizone/Long Island Power Solutions �, o��� .I�.S�do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. -2-1 2 ?� Owner's Signature Date Y t - 1 J ��✓ ►5 1 1 est.— `. Print Owner's Name 2 SVkLDING DEPARTMENT-Electrical Inspector -ea TOWN or SOUTHOLD Town HallyAnnex- 54375 Main Road - PO Box 1179 --.''-S-S56thold, New York 11971-0959 U- Q16p'1�ne (631) 765-1802 - FAX (631) 765-9502 r -southoldtownny gov — seandAsoutholdtownny.go -. APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: Catizone Electrical/Long Island Power Solutions Name:Michael Catizone License No.: 36178-ME email: sue@longislandpowersolutions.com Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 P JOB SITE INFORMATION (All Information Required) Name: Christine P'Simer Address:475 Pinewood Road,Cutchogue,NY 11935 Cross Street: Southern Cross Rd Phone No.:516-567-0179 Bldg.Permit#: email:cpsimer@comcast.net Tax Map District: 1000 Section: 110 Block: 3 Lot: 5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed(34)panel roof mounted array. (1 1.560)kW System Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All Information required) Service Size I Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected- Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form.xis f. 4% J LDING DEPARTMENT Electrical Inspector TOWN OF SOUTHOLD Town HalkAnnex- 54375 Main Road - PO Box 1179 11 C 'Wold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 rr southoldtownny.gqv.7sea ,O.@southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All information Required) Date: Company Name: Catizone Electrical/Long Island Power Solutions Name:Nfichael Catizone License No.:36178-ME email: sue@longislandpowersolutions.com ,Address: 2060 Ocean Avenue,Ronkonkoma,NY 11779 Phone No.: 631-348-0001 JOB SITE INFORMATION (AJI Information Required) Name: Christine P'Simer Address:475 Pinewood Road,Cutchogue,NY 11935 Cross Street: Southern Cross Rd Phone No.:516-567-0179 Bldg.Permit#: email:cpsimer@comcast.net Tax-Mcip-District: 1000, -;Section: I10 Block: -3. - Lot: 5 BRIEF DESCRIPTION OF WORK (Please Print Clearly) Proposed(34)panel roof mounted array. (1 1.560)kW System Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES/ NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected-Underground -Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional'lnformation:' .PAYMPENTMEWITH APPLICATION Request for Inspection Form.)ds PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments L LONG ISLAND C1 OWER 2060 Ocean Ave Ronkonkoma, IVY 11779 POL.0 T IOIS 631 348-0001 www.longislandpowersolutions.com April 7,2021 TOWN OF SOUTHOLD—Building Division Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold,NY 11971 Dear Building Dept: As per your Building Department, enclosed please find the building permit application, submitted on behalf of our client/property owner: Property Owner: Christine P'Simer—516-567-0179 Project/Property Address: 475 Pinewood Rd., Cutchogue,NY 11935 Section/Block/Lot: 1000-110-3-5 Electrician/36178-ME: Michael Catizone—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Contractor/53562-H: LI Power Solutions—2060 Ocean Ave.,Ronkonkoma,NY 11779—(631)348-0001 Architecture&Planning: Fisher Engineering Svcs.-509 Sayville Blvd., Sayville,NY 11782—631-786-4419 Enclosed Please find: • Application Fee: $200.00 • Permit Application • (4) Copies of the Property Survey • (4) Copies of the Engineering Drawings& Specs • Liability, Disability & Workman's Comp Insurance Certs Please send the Receipt and Permit to Long Island Power Solutions. Should you require anything further, please contact me. Sincerely, Sue Estabrooke Permit Manager Long Island Power Solutions 2060 Ocean Avenue Ronkonkoma,NY 11779 Ph- 631-348-0001 Fx- 631-348-0018 sue@longislandpowersolutions.com G® Green Save Green Suffolk County Dept of Labor,Licensing&Cqrtsuiriet Affalrr, MASTER ELECTRICAL LICIEN SE Name MICIiALL J CAT&-ON9 Cu3triess Name This cerl&s ftl the beWer is ddy lcwised by IN Cointy ofmircl.; Licenser Number:ME-36170 RoWle Drago 153ued: 126 112204 Crnnrnisamvngr Expires. 121011"22 Suffolk County Dept.of Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE Name MICHAEL CATIZONE Business Name This certifies that the LONG ISLAND POWER SOLUTIONS INC bearer is duly licensed by the County of suffolk License Number:ME53560 Rosalie Drago Issued: 0610612014 Commissioner Expires: 06/0112022 Suffolk County Dept.of Labor Licensing Consumer Affairs HOME IMPROVEMENT LICENSE yr Name MICHAEL J CATIZONE Business Name This certifies that the bearer is duly licensed LONG ISLAND POWER SOLUTIONS INC by the County of suffolk License Number:H-53562 Rosalie Drago Issued: 0510612014 Commissioner Expires: 06101/2022 NYSIF 199 CHURCH STREET,NEW YORK,N.Y.10007-1100 New York State Insurance Funs! I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE AAAAAA 271175107 ...T LOVELL SAFETY MGMT CO.,LLC } 110 WILLIAM STREET 12TH FLR NEW YORK NY 10038 �• Y 1 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER LONG ISLAND POWER SOLUTIONS INC TOWN OF SOUTHOLD 2060 OCEAN AVENUE 53095 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER I CERTIFICATE NUMBER POLICY PERIOD DATE Z 2467 078-8 146804 04/01/2021 TO 04/01/2022 03/09/2021 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2467 078-8, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK,EXCEPT AS INDICATED BELOW. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS:/IWViW.NYSIF.COM/CERT/ CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER CLAIMS OR SUITS THAT ARISE FROM BODILY INJURY SUFFERED BY THE OFFICERS OF THE INSURED CORPORATION. PRESIDENT MICHAEL CATIZONE VICE PRESIDENT JOSEPH MILILLO TWO OF TWO OFFICERS LONG ISLAND POWER SOLUTIONS INC THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS'COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 239995852 pp pp�I00000000000091 'f ���� III�II� I(NI1110Iulunomilummm�mnmmauaali®Illalla I�III1)111� 281603 Form WC-CERT-NOPENT Version 3(08129/2019)[WC Policy-24670788] U-26 3 41 [00000000000D91281603][0001-000024670788][##Z][15588-79][Cerk-NoP-CERT_l][01-00001] Client#:83393 LONGISL15 ACORM CERTIFICATE OF LIABILITY INSURANCE DATE(MWDD/YYYY) 2/25/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Commercial Support Edgewood Partners Ins.Center PHONE 631-390-9700 40 Marcus Drive E-MAIL EM• A/C No: 631-390-9790 ADDRESS: certificates@cookmaran.com 3rd Floor INSURER(S)AFFORDING COVERAGE NAIC If Melville,NY 11747-2647 INSURER A:Southwest Marine&General Ins Co 12294 INSURED INSURER B Long Island Power Solutions,Inc. 2060 Ocean Avenue INSURER C: Ronkonkoma, NY 11779 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS L1A TYPE OF INSURANCE INSR WUVD POLICY NUMBER POLICY EFF MPM/D YY) LIMITS A X COMMERCIAL GENERAL LIABILITY PK202100020693 2/28/2021 02128/2022 EACH OCCURRENCE s2,000,000 DgMAGE T RENTED CLAIMS-MADE X OCCUR PREMISES Ea occurrence $1OO OOO X PD Ded:5,000 MED EXP(Any one person) $6,000 X Contractual Liab. PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $2,000,000 POLICY[7X ECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER $ A AUTOMOBILE LIABILITY PK202100020693 2/28/2021 02/28/2022 COMBINED SINGLE LIMIT Ea accident 1,000,000 ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ X AUTOS ONLY X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY (MVP A X UMBRELLA LIAR X OCCUR EX202100001789 2/28/2021 02128/2022 EACH OCCURRENCE $5.000,000 EXCESS LIAR CLAIMS-MADE AGGREGATE $5,000,000 DED I X RETENTION$10000 $ WORKERS COMPENSATION PER I JOTH- AND EMPLOYERS'LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N EL EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? N/A (Mandatory In NH) EL DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Town of Southold Is included as additional insured for general liability coverage as required by written contract. CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 53095 Route 25 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971-0000 AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) 1 of 1 The ACORD name and logo are registered marks of ACORD #S2962740/M2962525 CPRAV YOR workers' CERTIFICATE OF INSURANCE COVERAGE STAT€ Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured LONG ISLAND POWER SOLUTIONS INC 2060 OCEAN AVE 6313480001 RONKONKOMA, NY 11779 Work Location of Insured(Only required if coverage is specifically limited to 1 c.Federal Employer Identification Number of Insured certain locations in New York State,i.e,Wrap-Up Policy) or Social Security Number 27-1175107 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Standard Security Life Insurance Company of New York Town of Southold P Y 53095 Route 25 3b.Policy Number of Entity Listed in Box"1 a" Southold, NY 11971 R97411-000 3c.Policy effective period 1/1/2015 to 9/14/2021 4. Policy provides the following benefits: Q A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: Q A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as desc d above. 441W— Date Signed 9/15/2020 By (Signature of insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES IMPORTANT: If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit,PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to Information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authonzed NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. �I DB-120.1 (10-17) VIII P1II2��I�I��1��II�(10iuioiiiiiii111l11 YORK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured Catizone Electrical Inc 631348-0001 575 Lexington Avenue,4th Floor - New York, NY 10022 1c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 455213112 Flame and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Utica Mutual Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"l a" 53095 Route 25 766763 3c.Policy effective period Southold,NY 11971 07/01/2020 to 07/01/2021 3d.The Proprietor,Partners or Executive Officers are ❑ included.(only check box if all partners/officers included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law. (To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.) Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Leonard Scioscia (Print name of authorized representative or licensed agent of insurance carrier) C � Approved by: 9/17/20 (Signature) (Date) Title: Authorized Reoresentative Telephone Number of authorized representative or licensed agent of insurance carrier: 631-390-9700 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov . • �• r i •Foy-/I/f.4�2+E { yJ.Q�is.d�rv.�l�.gT=Y t LOCATED AT GCJ WO e-'JS ,TO"OF�ov�7+�vc-fes 1 LOT . SUFFOLK coutm)CY. . MAP OF OaSCACM50-So P�egaE,2fy ° ,ca aac,r+o gLSp�� s ' as" sutfotx co.TAX MAP dATA:• DMA040 .SSC.mo.ao DWXP6 altt.Q3•� 11lT��� '� '"' ��� _w? DwcGi, Q * m tie . �a y �" � '� •�C!/,[r�- �,� e� o��v �r y a $ � � � is ��.� NV Jzl, /JAM \ QTY it/ar►�..c - � �`� '� •' � .di ?�c�owr,F..+,v�- , w -�3s7��a•or�- �8.c600 _ - ""�� ,ve Swv ro MAIM mmm ON SWM. ARE 'raft A Q� .� � ,14""` r•, WMM USE ONLY. AtO 0 SEAL �okQ& • 7�/7 /�95 SHOULD HOT Be USE'0 MR r,t: f. u.C.loc. A-M y- ,ray, /gfe- C COHMCWN OF fam MVEIP��T 26, f9'74eY Ci?a gyp• RAIAPARC NO BOURVBVWD P.C. E'Y"*, " • Mum" •s�tse,,sr.��+.os+;�rr.� .LL,Mf.Y.f19*T . OtUWN� 1� - �sernar � FS.E Mli.�,4OQvr- 4ewu�. i r Fisher Engineering Services, P.C. 509 Sayville Blvd • Sayville •New York 11782 Phone: (631) 786-4419 March 15,2021 Attention: Southold Building Department 54375 NY-25 Southold,NY 11971 Subject: Solar Energy Installation for P'Simer Residence- 475 Pinewood Road, Cutchogue,NY 11935 I have reviewed the roof structure at the subject address. The structure can support the additional weight of the roof mounted system. The units are to be installed in accordance with the manufacturer's installation instructions. I have determined that the installation will meet the requirements of the 20207 Residential Code of New York State and ASCE7-16 when installed in accordance with the manufacturer's instructions. Roof Section Rl Mean roof height 18 ft Pitch 27 deg Roof Rafter 2x10 Rafter spacing 16 cc Reflected roof rafter span 21.4 ft Table R802.4.4(1)max allowable 22.5 ft The climactic and load information is below: Ground Wind Live Load, Point CLIMATIC AND Exposure Snow Speed,3 Pnet per Pullout Fastener Type GEOGRAPHICAL DESIGN Category Load,Pg, sec gust, ASCE 7, Load, CRITERIA sf mph Psf lb Roof Section RI B 20 140 39 743 SS 5/16"dia lag bolt, 5"length Weight Distribution Array dead load 2.5 psf Load per attachment 27.2 lb Subject roof has one layer of shingles. Panels mount flush to roof no higher than 6 inches above roof surface. NE{�y Since William G.Fisher,P.E. Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections APPROVED AS NOTED ')ATE: ` '� B.P. CC-NIPLY WITH ALL CODES OF ® a,,: NEW YORK STATE & TOWN CODES �IOTlFY BUILDING DEPARTRlE �T A AS REQUIRED AND NDITIONS OF '65-1802 8A TO 4P FOR THE S OLD TOWN ZBA ' OLLOWING INSPECTIONS: FOUNDATION - TWO REQUIRED SOUTHOLD TOWN PLANNING BOARD FOR POURED CONCRETE SOUTHOLD TOWN TRUSTEES ROUGH - FRAMING & PLUMBING INSULATION N.Y.S.DEC FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE 3EQUIREMENTS OF THE CODES OF NEW ORK STATE. NOT RESPONSIBLE FOR ?ESIGN OR CONSTRUCTION ERRORS. OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY Additional Certification ,,,,,May Be Required ELEMWALVOMMON REQUIRED AERIAL Long Island POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 P ' SIMER P� RESIDENCE 475 PINEWOOD ROAD QQ� CUTCHOGUE. NY 11935 5� 516-567-0179 ®m G� S: 110 B: 3 L: 5 O QG PROJECT DATA: #214318 INVERTER: (34)ENPHASE 107-60-2-US MODULES: (34)Q.PEAK DUO BLK-G6+340 RACKING: IRON RIDGE XR100 O WATTAGE: 11,560 SHEET INDEX ROOF TYPE: COMPOSITION SHINGLES WIND LOAD: -56.2 PSF S-1 SITE PLAN FASTENER: USE 5116"DIA.5"LAGS S-2 DETAILS 7 N 9��ss O E-1 ELECTRICAL PLAN W o Fps L-1 MOUNTING PLAN 5 o � Z n .0 R-1 =m�Q .wo . # MODULES (34) Z w PITCH: 27° a°,y GENERAL NOTES AZIMUTH: 226° eco -ENPHASE IQ7 MICRO INVERTER LOCATED ON " Fss9 ROOF BEHIND EACH MODULE. T 3 Tye -FIRST RESPONDER ACCESS MAINTAINED 9� AND FROM ADJACENT ROOF. OF -WIRE RUN FROM ARRAY TO CONNECTION IS 40 FEET. -COGEN DISCONNECT IS LOCATED QP ,- O ADJACENT TO UTILITY METER. -LAYOUT SUBJECT TO CHANGE BASED ON GG SITE CONDITIONS AT DATE OF INSTALL ��'��0 x74659 ` LEGENDCD W � �< GROUND ACCESS POINT S TERAT10N OF THIS EXCEPT 7 LICENSED PROFESSIONAL IS ILLEGALBYA COGEN DISCONNECT PAPER SIZE:11"x17"(ANS16) UTILITY METER DATE:03/09/2021 N DESIGN BY: MW .0 5'-9" "- SKYLIGHT CHECKED BY: SG S REVISIONS: >_ REPRESENTS ALL FIRE CLEARANCE FIRST RESPONDER ACCESS 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, o / INCLUDING ALTERNATIVE METHODS MINIMUM OF 36"UNOBSTRUCTED AS PER TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE?-10. SITE PLAN THE 2020 RESIDENTIAL CODE OF NYS — - .� .� _4 r. • �_ _ _ lronRidge XR 100 Rail aw. Long Island POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 P ' SIMER �'►' RESIDENCE _--- Flashing 475 PINEWOOD ROAD CUTCHOGUE, NY 11935 cAcw"p 516-567-0179 S: 110 B: 3 L: 5 Iroti idge XR 100 Rail n PROJECT DATA: #214318 ItouRidgeXR 100 Reil (5/16 X 5n Stainless INVERTER: (34)ENPHASE IQ7-60-2-US Steel Lag Bolt MODULES: (34)Q.PEAK DUO BLK-G6+340 �+ RACKING: IRON RIDGE XR100 Solar Module WATTAGE: 11,560 3/8-16 X 3/4 HEX MEAD DOLT ROOF TYPE: COMPOSITION SHINGLES 3f8-�8 Ft ANGE_ NUI �1,� WIND LOAD: -56.2 PSF 3-5/8" FASTENER: USE 5/16"DIA.5"LAGS U to U U tr; r w U � N GENERAL NOTES: "mPP � - q -L FEET ARE SECURED TO ROOF RAFTERS @ 80" O.C. wLU 0. <_- W .N Z t$W USING 5/16" x 5" STAINLESS STEEL LAG BOLTS. LU WE -SUBJECT ROOF HAS ONE LAYER. 3 -ALL PENETRATIONS ARE SEALED AND FLASHED. �P �'d� G•s �Q m ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL IS ILLEGAL ROOF PITCH RIDGE RAFTERS LENGTH OVERHANG NOTES PAPER SIZE:1 1"x 17'(ANSI B) DATE: 03/09/2021 DESIGN BY: mw o I. EXITING KNEEWALL 5'-6" FROM RIDGE, CHECKED BY: SG R1 27 2x12 2 x10 @16 O.C. 371-41f 12 HEADER 12'-2" FROM RIDGE REVISIONS: E DESIGNED AS PER ASCE 7-10 ? 2020 RESIDENTIAL CODE OF NEWYORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, R MODULES MOUNTED FLUSH TO ROOF TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7-10. DETAILS tr NO HIGHER THAN 6"ABOVE ROOF SURFACE r Long Island " POWER SOLUTIONS 2060 OCEAN AVENUE, RONKONKOMA, NY 11779 (631)348-0001 21-711 P ' S M E R RESIDENCE 475 PINEWOOD ROAD CUTCHOGUE, NY 11935 516-567-0179 S: 110 B: 3 L: 5 PROJECT DATA: #214318 INVERTER: (34)ENPHASE IQ7-60-2-US MODULES: (34)Q.PEAK DUO BLK-G6+340 i RACKING: IRON RIDGE XR100 WATTAGE: 11,560 ROOF TYPE: COMPOSITION SHINGLES WIND LOAD: -56.2 PSF 37 —411 FASTENER: USE 5/16"DIA.5"LAGS Ln u m u r U O N di > o � z o T J m Z LLi 3 m K w a z Lu .N w s u m l Zw �Q� w C� K E Lu Im NFA 17' 0 R-1 `�A -.07469 14' -- --- - 15 # MODULES (34) �• �`�ss 11` 4 PITCH: 270 ALTERATION OF S DOCUMENT EXCEPT BY A 4' 0 THIAZIMUTH: 2 2 6 O LICENSED PROFESSIONAL IS ILLEGAL c+ 0 PAPER SIZE:11"x 17"(ANSI B) v C14 ■ SPLICE BAR 12 DESIGN BY: MW © PENETRATIONS 57 31-511 UFO 80 11 CHECKED SG 40MM SLEEVE 2451-911 END CAPS 24 cpN CONSUMPTION CRITTER GUARD 166' MOUNTING PLAN L— 1 PHOTOVOLTAICS: Long Island (34) Q.PEAK DUO BLK-G6+ 340 POWER SOLUTIONS NEMA 3R 2060 OCEAN AVENUE, JUNCTION BOX INVERTERS: RONKO(631)348-0)348-0NKOMANY 11779 001 BLACK- L1 ENGAGE CABLE (34) ENPHASE I07-60-2-US RED- L2 CIRCUITS: P ' S I M E R WHITE- NEUTRAL GREEN-GROUND (1) CIRCUIT OF (12) MODULES _ (2) CIRCUITS OF (11) MODULES RESIDENCE 475 PINEWOOD ROAD CUTCHOGUE, NY 11935 516-567-0179 S: 11013: 3L: 5 PROJECT DATA: #214318 INVERTER: (34)ENPHASE IQ7-60-2-US #12 AWG THWN FOR HOME RUNS UN ER 100' MODULES: (34)Q.PEAK DUO BLK-G6+340 #10 AWG THWN FOR HOME RUNS OVER 100' I PHOTOVOLTAIC II I RACKING: IRON RIDGE XR100 (1)LINE 1 WATTAGE: 11,560 (1)NEUTRAL i DISCONNECTt METER ROOF TYPE: COMPOSITION SHINGLES WIND LOAD: -56.2 PSF (1)GROUNDWMff PER CIRCUIT © © ' 34 FASTENER: USE 5/16"DIA.5"LAGS 0 IN 1"OR 17"PVC CONDUIT d0�1�1!lt 0MTWACnTA%240 V u N ELECTRIC , • DO NOT TOUCH TERMINALS TERMINA'S ON 607 H THE LINE AND PHOTOVOLTAIC LOAD SIDES MAY BE ENERGIL'77' MAIN SOLAR SYSTEMIN THE OPEN POSITION AC DISCONNECT LINE SIDE TAP z o .� Z � N w � N _ E 3 60A FUSED SERVICE MAIN SERVICE 125A LOAD CENTER RATED 200A DISCONNECT �� OF �IFyy (1)-20A BREAKER G, PER CIRCUIT 50A FUSE L! j WARNING DISCONNECT INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS #6 AWG THWN #6 AWG THWN OVERCURRENT DEVICE (1)LINE 1 (1)LINE 1 ,)• SES$ �- -_._.�!�-. __�____ __, __.___•�.___.._, (1)LINE 2 (1)LINE 2 m (1)NEUTRAL (1)NEUTRAL AC DISTRIBUTION PANEL ALTERATION OFTMS DOCUMENT EXCEPT BYA z (1)EGC (1)EGC LICENSED PROFESSIONAL IS ILLEGAL IN 1a'PVC CONDUIT (1)GEC OR SUB PANEL PAPER SIZE:11"x n"(ANSI B) 7 IN 11"PVC CONDUIT DATE: 03/09/2021 DESIGN BY: MW CHECKED BY: SG REVISIONS: AC COMBINER: NOTE: 2020 RESIDENTIAL CODE OF NEW YORK STATE,2020 ENERGY CONSERVATION CODE OF NEW YORK STATE, 1-PHASE,MAIN LUG LOAD CENTER, 125A ALL WIRING TO MEET THE 2017 NEC AND 2020 ENERGY CODE TOWN OF SOUTHOLD CODE,2017 NATIONAL ELECTRIC CODE.ASCE7-10. ELECTRICAL PLAN E- 1 s 60A FUSED SERVICE RATED DISCONNECT „ ,powered by e DUO tz GCELLS nmswrarY ” �. �' Quality Tested i oomme� �,EUROPE(,�-t w 3a ¢Z01.9 ID 40032587 Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area,lower BOS costs,higher- power igherpower classes,and an efficiency rate of'up to i9.5%.' INNOVATIVE ALL-WEATHER TECHNOLOGY Optirnal,yjelds,whatever the weather with excellent low-light and temperature behavior. - _ ENDURING HIGH PERFORMANCE,{' Long-term•yield security with Anti L"IWsnd:Anti PID Technology', ` , Hot=Spot Protecf and Traceable_Qualitq`Tra.Q'"'. EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow (5400 Pa)and wind loads(4000 Pa). © A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. > STATE OF THE ART MODULE TECHNOLOGY r S Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology., 'APT test conditions according to IEC/TS 62804-1,2015,method B(-1500V,168h) 'See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany OCELLS MECHANICAL SPECIFICATION Format 68 5 x 40 6 x 126 in(including frame) (1740 x 1030 x 32 mm) —6a6 n1d0mm' zs°•IUD—]mm) Weight 43 9lbs(19 9kg) � ' 38 68'(980 =463•(1160mnj Front Cover 013 in(3 2mm)thermally pre-stressed glass ^ - - withanti-reflection•technology, 4.0..m p, aiMr(45mn) Back Cover Composite film 3a9r ryazmmj Frame Black anodized aluminum I ; -. ® aasno3ommj , Cell - 6 x 20 monocrystalline;Q QNTUM solar half cells ` ,Junction Box 2.09-3 98 x 1_26-2.36,()59-0 71in(53-101 x 32-60 x 15-18 mm),Prctection'class'IP67,with bypass diodes Leba� =4s3 vsommj Cable 4MM2 Solar cable,(+)>-453in(115Omin),(-)?453m,(1150mm) 94kh".hdw b ,a.r+wMnreawwEraLAj - Connector Steubh MC4,Hanwha Q CELLS HQC4,Amphepol UTX;'_ Renhe05-6,TonglingTL-Cable01S,JMTHYJM601j,IP68or I� iz9(3zmmj oEruLAae3mpcmmj Friends PV2e,IP_67Ia3as(esmm> ELECTRICAL'CHARACTERISTICS -POWERCLASS =ms's_2� z -^"°�s< a3y`�:a,nF�k,-,>.;k3 b' ,T.r ^33C''� 340'x', :�" ny :, " 3, t �5 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS;'STG=(POWER TOLERANCE+5W/-OW) .�4 Power at MPP' PMPP In- ' 330 3�5 340 345," Short Circuit Current' Isc [A] 1041 10:47 10.52 10.58'' E Open Circuit Voltage'- Voc N] 40.1b 40:41 40.66 ^ Current at MPP IMP [A] -991,- 9 97 14.42 ?" 'VoltaSeatMPP, VMPP' [V] 3329 33.6 3 94 ``' '+`,, 2;' 34:25; ",y r,_;J'r:.4 ' '• Efficiericy' q, [%] a18 4 a18 7 e19 0 ?1 3'y=. � s•,.� f,.i; _ i11N],MUhA PERFORMANCE AT NORMAL OPERATING CONDITIONS,-'NMOTZ ,Power'atMPP PMPP [W] 247.0 250'7 254.5 E Short Circuit Current Iso [A] 8.39 8.43 848 .0 Open Circuit Voltage Voc [V] 3786 38.10 38.34 s;3$:59.,,''�;',..,;;;s:,L`;•,„{�� Current at MPP IMPP [A] 7.80 7.84 Z89 Z93' y -� pan Voltage at MPP VMPP [V] 3166 3197 3227 tMeasurement tolerances P, ±3%,I3c;,Voc t5°&at STC.1Q00W/m1,25±2°C,AM 15 according to IEC 60904-3.2800 W/mz,NMOT,spectrum AM L5 O,CELL-S' PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE � ,, . amts uo --T-----r-----i----1------ At least 98%of nominal power during , , _W ter-------------- first year Thereafter max 054% ° ;``:".•" ------------------------------- degradation degradation per year.At least 93.1% u rco of nominal power up to 10 years At $ '+ z '0 -------------- least 85%of nominal power up to 30 25 years --r-----,----- -----*-----' Ail data within measurement tolerant- z .° es.Full warranties in accordance with '0 � 0 _ - aoo +co coo zoo 4ccc o ” - the warranty terms of the Q CELLS inanola ucE tx rm t - sales organization of your respective o country. s,maxarnemwvmaaioma towwP.+a rEdas Typical module performance under low irradiance conditions in 5 WA Yn Nd�APeNNm nPdMn3m4(e,a Segom6vX°q N comparison to STC conditions(25°C,1000 W/mz), a 7EMPERATURE,COEF0I6IENTS, , Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Voc S [%/K] -027 Temperature Coefficient of PMPP y [%/K] -0.36 Normal Module Operating Temperature NMOT [°F] •109±5.4(43±3°C) m PROPERTIES FOR SYSTEM DESIGN Y a Maximum System Voltage Vsys [V] 1000(IEC)/1000(UL) Safety Class II o Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 1703 C(IEC)/TYPE 2(UL) Max.Design Load,Push/Pull' [lbs/ftp] 75(3600Pa)/55(2667Pa) Permitted Module Temperature -, -40°Fup-to+185°F Max.Test Load,Push/Pull' [lbs/ftp] 113(540015a)/84(400013a) on Continuous Duty (-40°C up to+85°C) m 3 See Installation Manual m r V QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION - . m UL 1703,VDE Quality Tested,CE-compliant,IEC 612152016,IEC 61730 2016, Number of Modules per Pallet 32 8 Application Class 11,U S Patent No 9,893,215(solar cells) Number of Pallets per 53'Trailer 28 a C S�® Number of Pallets per 40'HC-Container 24 DVE c mus Pallet Dimensions(L x W x H) 715 x 45 3 x 48 0 in(1815 x 1150 x 1220 mm) 8 Pallet Weight 1505lbs(683 kg) a Note:Installation instructions must be followed See the installation and operating manual or contact our technical service department for further information on approved installation and use ' of this product Hanwhe Q CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 961 EMAIL inqu,ry@us q-cells com I WED www q-cells us Data Sheet Enphase Microinverters Region AMERICAS The high-powered smart grid-ready Enphase Enphase IQ 7 Micro" and Enphase IQ 7+ Micro' dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and 'IQ 7+ Microinverters integrate with the Enphase 1Q Envoy', Enphase IQ,Batterym",and the Enphase EnlightenTm monitoring and analysis software. IQ Series Microinverters-extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry=leading warranty of up to-25 years. Easy t6-install " • Lightweight and simple Faster installation with improved,lighter two-wire cabling r Built-imrapid.shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high,powered 60-cell and 72-cell*modules • More than a million•hours of testing Class Ildouble-insulate,••enclgsure' -- • UL listed Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements Remotelyvpdatesto respond-to changing - grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U *The IQ 7+Micro is required to support 72-cell modules EN Pe-IAS E. To learn more about Enphase offerings,visit enphase.com Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-0-US 'Commonly'u'sed.module pairings' 235 W-350 W+ 235 W-440 W.+ " Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules maximum DC voltage 48 V 60V Peak power tracking voltage 27 V-37 V 27 V-45 V "Operating range;_ 16V-48V`' ;,16 V=60 V, Min/Max start voltage 22V/48V 22 V/60 V ;,Max D, s,ort,c''iit=cuit current(module lsc�',', 15 A, Overvoltage class DC port II II OC,porfbackfegdcurr_ent , ,,.. "" OA; ;;,: ?0 A, , PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Pea koutput%power= " ,2501/A - „ 295VA' Maximum continuous output power 240 VA 290 VA .No Ina,, Cs-'VgltagelraTr e?s 240,V 1' 20&V-/ 240 V,-/: .208 V/--, 217-264 V >183-224 V 211-264 V' 83-229 V- Maximum continuous output current Y 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) - Extended frequency range 47-68 Hz 47-68 Hz ot ' 5,8,km�00G6 y:cla 8Armss- Maximum units per 20 A(L-L)branch circuit3_ 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) - r AC port backfeed current, 0 A 0 A �f e ora t" Power„factor(adjustable) 0.7 leading .0.7 lagging 0.7 heading..0.7 lagging EFFICIENCY @240 V @208 V @240,V @208 V ;'`;Pea c'OEC:EffiCiBiiC97.6-%, 97.6-,0/, =Y 7777777 CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA i. ! Ibeer}ipittrr rorv.=_;_,' Rp,.,_. =40°C to,+65"C - : _ Relative humidity range 4%to 100%(condensing) Cortnec#or''t3+ejQ7 6Q =t1S&I(27PGtJS172.2-1JS::MC4;or Am hens(-k�4'11T�('titatldi#ioaal•Q=DCC-Ssada`ter Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 -PV2 to UTX:order ECA-S20-S25 Diiriensioiis-(lNZktxD�, ��212xininzc�77S'rrirri�x=80:2"riim:without�b`r`acket Weight 1.08 kg(2.38 lbs) :- �{C';,o•i>, .1,:; ��'�� ,`Natural ,Q 1119 - ,_ _ _S"=-,_-Az<:.��^�n,i� '«2,iw.. bvi _ _,.. .,,� , .. . >. ,.ar✓S.i`-.aZ�zai=s;Y�,x=rG �,k�.� � ��,-f ,. r, ,.> Approved,for wet locations Yes T Poll -.;.PDB Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Envirdnrrte tai ca ego y, lY posu> ;ritlpg,. NEMA.Type67i,iitiioor'T FEATURES :(jU, t10rt"`..; r, - .. *.c»;�'- n?t�'`a,}`%c ir .,^ r�..,•`� "�:.' - omr11,nica :` ;x Poi,ver,.Lirie,C6rrirYturiioation'(PLC ;,n `w ;r ':;, Monitoring Enlighten Manager and MyEnlighten monitoring options., Both options require installation of an Enphase IQ Envoy. Discannecting''mearis` TheAC,and.bC connectors have,tieen evaluated arttla' ro�ed'by<kUt forla'ses,heNlciad';Urea :==: dis oRne trequiretlb 'NEC'690.- .t,R - ,y . �s .A„ > . ,.< - , -_''�rir�e, aYn'k -.''x'fu>t?sv'::. o.?�,.. ,.,•,_. Compliance CA Rule 21 (UL 1741-SA) " UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class b, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httos//enphase.com/en-us/support/`module-compatibilit 2.Nominal voltage range can be extended beyond nominal if required by the utility 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com Oa E N P H AS Em ©2018 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc 2018-05-24 IRON RIDGE Roof Mount System �'ss'`fir +"��"r�;"'."��}����='`��x,��"' -fr�• � brf � ,��i�,,- 4.��� Y =a,Ky. <rZf Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in-extreme environments.._;. ,;.,_ Our rigorous ap j roach has led to unique structural features, such.,as curved rails and reinforced,flashings, and is also whyourfroducts are full certified, code compliant and backed by a 20-year warranty. pvs A- Y �_'i,erfigtla Tested.,.- -^PE'Certified 'Al[Wirriponents evaluated for:superior Pre-stamped engineering-letters - - structural performance. available in most states: -> ,Class A Fire Rahn ___,Design,Software, - ------ -- - - ----------- - -- - ----- ----- -- - - -- ------ -- -- - - -- - Certified to maintain the fire resistance Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding20 Year Warranty UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. 0 R Brits XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q �F „:�:=.;:��r tea;"'.-r��� 5��� ^;� � •�sxr °�F''-.zit2*.,•�viz; � 54, .���6, :��`'a.�a3`�;yE.�4„r,�ry A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. 'solar mounting rail• rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability • 12'spanning capability - Self-tapping screws • Moderate load capability Heavy load capability • Extreme load capability - Varying versions for rails • Clear&black anod.finish,-” Clear&black anod.finish • Clear anodized finish - Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs AM t W Lam Anchor, flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware - High-friction serrated face • Works with vent flashing • Attaches directly to rail • IBC& IRC compliant • Heavy-duty profile shape • Ships pre-assembled • Ships with all hardware • Certified with XR Rails - Clear&black anod.finish • 4"and 7"Lengths • Fixed and adjustable Clamps & Grounding End Clamps Grounding Mid Clamps Q T Bolt Grounding Lugs.0.-,, v Accessories Slide in clamps and�secure- v. Attach-and ground modules Ground-system using the,,--, Provide,a,finished and modules at ends otrails.1, :`---, in the middle of the rail. rail's top slot. ,,organized,look for rails. • Mill finish&black anod. • Parallel bonding T bolt • Easy top-slot mounting • Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times - Eliminates pre-drilling • Perfected End Caps • Optional Under Clamps ' •'Mill&`black stainless • Swivels in any direction"-,' UV-protebted polymer Free Resources Design Assistant A NABCEP Certified Training _ -- - - Go from rough layout to fully V I' Earn,free continuing education credits, engineered system. For free. A A, while learning more about our systems. �- Go to IronRidge.com/rrn V® Go to lronRidge.com/training