Loading...
HomeMy WebLinkAbout46713-Z � TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE !0 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF' APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 46713 Date: 8/19/2021 Permission is hereby granted to: Mattituck Plaza LLC BOX 77 PO .......... www_____ _....._.__ wwww .... �___. w..w.w..,v�w.� ....._... P Mattituck, NY 11952 To: Construct interior alterations to existing retail space (Unit 9, AT&T) at Mattituck Plaza, as applied for. At premises located at: 10095 Route 25, Mattituck SCTM # 473889 Sec/Block/Lot# 142.-1-26 Pursuant to application dated 8/10/2021 and approved by the Building Inspector. To expire on ............2/1.8./20.23........ Fees: COMMERCIAL ADDITION/ALTERATION $572.80 CO-BUSINESSES $50.00 Total: $622.80 Building Inspector �� � �� TOWN OF SOUTHOLD—BUILDING DEPARTMENT °w Town Hall Annex 54375 Main Road P. O. Box 1179 Southold NY 11971-0959 Telephone (631) 765-1802 Fax (631) 765-9502 Date Received APPLICATION BUILDING PE I"Ir For Office Use Only r AUG PERMIT NO. Building In;sPettat;,,_, Applications and forms must be filled out in their entirety. IncompleteP, applications will not be accepted. Where the Applicant is not the owner,an 7,1 " Owner's Authorization form(Page 2)shall be completed. Date:August 10, 2021 OWNER(S)OF PROPERTY: Name:Cardinale Management " SCTM# 1000-142-1-26 Project Address: 10095 Main Road, Mattituck, NY Phone#:631-445-4432 Email:aacjN-Poptonline.net Mailing Address:10095 Main Road, Mattituck, NY, UNIT 4 CONTACT PERSON: Name:Michael Hand Mailing Address:PO BOX 1256, Mattituck, NY 11952 Phone#:631-965-1947 Email:michael@mchdesignservices.com DESIGN PROFESSIONAL INFORMATION: Name:JamesDeerkoski Mailing Address:260 Deer Path, Mattituck Phone#:631-774-7355 Email:jamesdeerkoski@yahoo.com CONTRACTOR INFORMATION: Name: (owner) Mailing Address: Phone#: Email: DESCRIPTION OF PROPOSED CONSTRUCTION ❑New Structure ❑Addition Alteration ❑Repair ❑Demolition Estimated Cost of Project: ❑Other $10,000.00 Will the lot be re-graded? ❑Yes 8 No Will excess fill be removed from premises? ❑Yes ❑No 1 PROPERTY INFORMATION Existing use of property: Business Intended use of property: Business Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to B this property? ❑Yes ❑No IF YES, PROVIDE A COPY. Check Box After Reading: The owner/contractor/design professional Is responsible for all drainage and storm water issues as provided by Chapter 236 of the Town Code. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk,County,New York and other applicable laws,Ordinances or Regulations,for the construction of buildings, additions,alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code, housing code and regulations and to admit authorized Inspectors on premises and in'building(s)for necessary inspections.False statements made herein are punishable as a Class A misdemeanor pursuant to Section 210.45 of the New York State Penal Law. Application Submitted By(fir n name): �Annett Schumacher r99Authorized Agent ❑Owner ,w Signature of Applicant:�„ �' ��„ ��� Date: August 10, 2021 STATE OF NEW YORK) 9 C11 COUNTY OF �” L11 ) �X , -/ ` being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the 71 (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this 1_day of (f.�ys�20 202"L Notary Public Samantha Beisacher Notary Public, State of New York Cnmmission Expires,June 7, here the applicant is not t le)ow r) No. 01 BE6418 68, Suffolk Co OPERTY OWNER owner) 1, residing at do hereby authorize to apply on my behalf to the Town of Southold Building Department for approval as described herein. Owner's Signature Date Print Owner's Name 2 Town Hall AnnexTelephone(631)765-1802 fol, 54375 Main Road Fax(631)765-9502 P.O. Box 1179 ) �� Southold, NY 11971-0959 � � a / BUILDING DEPARTMENT' TICS OF UTILIZATION OF TRUSS TYPE CONSTRUCTION, PRE-ENGINEERED WOOD CONSTRUCTION ANDS/ R TIMBER CONSTRUCTION Date: Owner: .���...� ... Location of Property: . ..�.............................. c� .......,,,,.. _ Please take notice that the (check applicable line): New commercial or residential structure Addition to existing commercial or residential structure Rehabilitation to an existing commercial or residential structure to be constructed or performed at the subject property reference above will utilize (check applicable line): Truss type construction (TT) Pre-engineered wood construction (PW) Timber construction (TC) in the following location(s) (check applicable line): Floor framing, including girders and beams (F) Roof framing (R) Floor and roof framing (FR) .. Signature: � �.�.... ••... Name (person submlftin this form _ �' Capacity(check applicable line): Owner ..............._... Owner representative TrussReg15.docx Effective 1/1/2015 Building Della x1ment An Wfi—efition AU,T,I,',,,(,,ORI,ZATION (Whem the Applicant N not die Ownw) ..... residingat 100?5 Mal ' ....... ................... (Print property awner's nwne) (MaRing Addmw) (Agent�) ......................................... to apply on my behalf to the Southold Budding Depm=ent ..................R............ ..... ...................................... .................... Pner"s"S'ignatum) (Date) ...... n Ian ..... (Print Owner's Name) 14(8.- /-z� �ss�ss ors i _ DRIVEWAY +/- 58' - 3" 3 EXISTING DESIGN CRITERIA 13 - 11 43' - 11" BLDG. CODE NYS zozo IBC FRAMING ELEMENTS AS PER FLOOR PLANS GROSS SECTION AND GENERAL NOTES EXT. BALCONIES 4' - 11" 12" 4' - 11" 12" 4' - 10" +/- 18' - 11" 100DECKs � DESIGN LOAD CALCULATIONS 100 45 ^ EXISTING STOREFRONT (LIVE LOADS PSF) ROOF (GROUND SNOW LOAD) 45 L 3 ALL FLOOR LOADS 100 _ - - - - - _ — - - - - - - - - - - - _ - - _ - - _ STAIRS 100 Design Services - - - - - - - - - - - - - - - - - - - - - - - - _ — _ - - - _ - - GAURDRAILS (ANY DIRECTION) 200 —I EXPOSURE CATAGORY C 4. ' LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION A` I (ROOF - FOUNDATION) ETAIL PAGE 4 GENERAL NOT AGE 77 www.mchdesi nservi a . O — — — — _ m SEE GENERAL NOTE PAGE hone: NAI ING SCHEDULE g ceS com � � FIRE i p EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE (631)298-2250 ' EXTINGUISHER EXISTING FIRE PROTECTION Sym'` NEW BACK OF 10'-0"AFF N o SEE FLOOR PLANS ELECTRICAL HOUSE 2 (SMOK 4 CO2 DETECTORS) email: EO MWU MWU IP-D It I TRUSS DESIGN N/A - STEEL TRUSS CONSTRUCTION michael@mchdesignservices.com PANELS 104 44"X86"Sm Comm Table t- ENERGY CALCULATIONS COMC 'ECK 7' - 6" 7' - 6" 1 A201 3 Z CLIMATIC & GEOGRAPHIC l 1 o DESIGN CRITERIA -' 0� Ur GROUND WIND SEISMIC FROST WINTER ICESHIELD WALL IT-R� K OF AATV 4 4' - 0" LL Z SNOW SPEED DESIGN WEATHERING LINE TERMITE DE FLOOD L J LT-S LT-S-ADA �_� I W LOAD (MPH) CATEGORY DEPTH DECAY DESIGN UNDERL REQUIRED HAZARDS J I I I LT-S M 0 O � Y MODERATE SLIGHT TO TEMP. REQUIRED ilfI I rf AATV-LRG LT-D-ADA i I LO W Fz 20 LBS. 120 B SEVERE 3 FT. TO HEAVY MODERATE 11 NONE C7 L EXISTING U) z0 06 LT-Di ¢ \ 10'-0"AFF I + Z + W Y ¢ _ L _ 1, 2 SALES J W LT-S LT-S LT-S-ADA X 3. 2 1 S-0. - _ 101 I W z/ w INTERIOR WALLS AND CEILING PER TABLE 803.5 NYS CODE ¢ I R O I VESTIBULE - -�- - - - - - - - - - - - - - - - - - - I` 702 SF o ' — - - — - — - — ' — - — - — - —� 44.5'ESCAPE C0 YERTICLE EXITS AND EXIT ACCESS CORRIDORS ROOMS AND W ~ , `03 I i / 102 N MWU MWU ~ - \ PAT I EXIT PASSAGEWAYS AND OTHER EXITWAYS ENCLOSED PASSAGEWAYS O i�r- I BCW- RG MWU MWU — H '� - \ ' IS Z o — — — — — — — — — — — FIRE M C i W — - - - - - - - - - - - - Z - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — J W ACT-1 ACT-1 - U USE AND OCCUPANCY CLASSIFICATION: � 9'-0"AFF 9'-0"AFF GROUP B 4' - 11" 4' - 11" 12' OFBCW 12' 4' - 11" 4' - 11" 7' - 2" 6' - 4" 19' - 611 TYPE 3 BUILDING MIN. EGRESS AS PER SECT. 1003.3.1.1 EXITS AS PER TABLE: 1005.2.1 ADJACENT TENANT: FUTURE LAB CORP 1.NO STRUCTURAL CHANGES TO BE MADE 5.INSTALL AND ALTER LIGHTING AND OUTLETS PER TO EXISTING BUSINESS SPACE(ALTERATIONS CODE AND OWNER SPECIFICATIONS FOR MEDICAL ONLY). AND OFFICE EQUIPMENT. 2.OPENINGS TO BE CLOSED OFF NEXT TO ADJACENT 6.SMOKE AND CO DETECTORS TO BE INSTALLED AND SITE DATA & ZONING INFO 4 BUSINESS SPACE TO BE 1 HOUR FIRE RATED. REPLACED TO CODE.INSTALL FIRE EXTINGUISHERS AS REQUIRED. O BATHROOM SPECIFICATIONS 3. GYPSUMWALLB1 HOUR FIRE WALLBOARD.D WALLS TO BE DBL 5/8" OCCUPANCY CALCULATIONS (TABLE 1004.1.2) �---� �""I GYPSUM WALLBOARD.(UL DES U305,U314 7.EMERGENCY LILTING AND LIGHTED EXIT SIGNS TO BE INSTALLED AS REQUIRED. ��� N.T.S. 4.EXISTING SPRINKLER HEAD LOCATIONS TO COMPLY BUILDING AREA: 93 2 SQ. FT. (�] WATER WATER WITH NFPA REQUIREMENTS. 8.OWNER TO NOTIFY SCHD FOR PROPOSED WORK. /1� � rT, CLOSET CLOSET �/ � ^ - h�'-1 r All work to be compliant to ICC/ANSI 2009 OCCUPANCY: BUSINESS GROUP B P-1 Z 60"MIN. LAVATORY 13„ DIMENSION POINT F.A.I. VINYL EDGE STRIP- VCT FLOORING V UI Water Supply and drain pipes under lavatories z4" z" JOHNSONITECE-XX-A, OCCUPANCY LOADS: 932 SF / 1/150 - 6 rill and sinks shall be insulated or otherwise TOP OF CONCRETE COLOR 63 BURNT UMBER — Z U EE 4 2 4 configured to protect against contact. There C.O. 1-1 16" �Z)GLUE-DOWN CARPET H 4 ::;E TYPE OF CONSTRUCTION: TYPE 3 LW (� shall be no sharp or abrasive surfaces under lavatories and sinks. 6-1s Accesible lavatories and sinks are to comply 4 — ALTERATION LEVEL: 3 with Section 606 . FRONT ELEVATION. To APROVED • ,' ,••a• , .0 4"C.I. SEWER A clear floor or ground space complying TRAP HOUSE ,..;. ,,, • ..; ' ' ., . ., � •�. ,,, .. .° . .. with Section 305.3, positioned for foward PROPOSED FLO0R PLAN LAYOUT j . approach, shall be provided. Knee and toe VERT. JOHNSONITE MTC-00-A clearance compling with Section 306 12"MAX BAR SCALE: 1/4" = V-0" shall be provided. 42"MIN.--i 1 HOUR FIRE WALL REQUIREMENTS FINISH PLAN KEY N FINISH PLAN GENERAL NOTES The front of lavatories and sinks are to be OTES A. FOR ALL WALLS WHERE NO FINISH OR BASE IS INDICATED,SEE 34 inches maximum above the floor or wt.7 5/8"$HEETROCK FIRECODE Core panels,or UL Des 0305, 32 RAL-TL11-129 A-59 O PROVIDE TRANSITION STRIP AT THIS LOCATION,DETAIL 2/A103 INTERIOR ELEVATIONS SHEET,A201. • ground, measured to the higher of the7 71-1-. _ 5/8"SHEETROCK UltraLlght panels RRECDDEX U314 Based on 5/8"SHEETRDDK FIRECODE corp fixture rim or counter surface. 433/4' or 5/8"FISEROCK panels panels,no sound bat B. ALL VCT SHALL BE WAXED PRIOR TO TURN OVER. Faucets shall comply with Section 309. -2 x 4 wood stud 16"or 24"O.C. FURNITURE & FIXTURE PLAN KEY NOTES C. ALL BACK OF HOUSE DOORS AND FRAMES(ALUMINUM SIDE ELEVATION -optional Insulation 33 RAL-TL11-172 Hand-operated, self-closing faucets shall Based on 5/8"SHEETRDCK UltraLight Panels 1 NEW GWB PARTITION STOREFRONT NOT INCLUDED)TO MATCH ADJACENT WALLS. remain open for 10 seconds minimum. Firecode X,no sound bat 2 NEW T-0"X T-0"WOOD DOOR D. PAINT ALL SALES FLOOR DOORS AND FRAMES TO BE PAINTED TO Sinks are to be a maximum 6-1/2" deep. 36"GRAB BAR 34 """""""""""""""""""".1 1.3.""" 3 NEW BLACKOUT FILM ON EXISTING STOREFRONT GLAZING MATCH ADJACENT WALLS.EXCEPT SEMI-GLOSS. Multiple compartment sinks shall have (33-36'�ABOVE FLOOR) 3a RAL-TL11-173,RAL-TL11-130 Based on 5/8"SHa7fucK FIRECODE Core? 4 NEW PLUMBING FIXTURES E. RUBBER BASE WILL NOT BE INSTALLED UNTIL ALL WALLS HAVE at least one compartment complying with panels or 518"SHEEMOCK UltraLlght Panels 5 NEW T-0"X T-0"CASED OPENING RECEIVED THE FINAL COAT OF PAINT. the requirement. FIRECODE X with R-11 fiberglass sound bat 34" • •. . ... ..... ... F. WHERE DEMOLITION OCCURS ADJACENT TO EXISTING, PATCH AND Based on double layer one side 518" MAX 37 RAL-TL11-081'RAL-TL11-084 REPAIR ADJACENT CONDITIONS FOR A UNIFORM APPEARANCE. SHEETROCK FIRECODE core panels or 5/8"' G. ALL SURFACES TO BE BRUSHED AND ROLLED EXCEPT HVAC GRILLS SHEETROCK Uftratight Panels FiREcoDEX WHICH ARE TO BE SPRAYED. HEIGHT OF LAVATORIES AND SINKS with R-11 fiberglass sound bat H. ALL SURFACES TO RECEIVE THREE COATS-1 PRIMER AND TWO FINISH. ` I. CREATE CRISP/CLEAN LINE BETWEEN ALL COLOR CHANGES. FINISH LEGEND NOTE: NOT ALL ITEMS LISTED HERE WERE USED IN THIS PROJECT J SPAINT ANDINGNTRACTOR TO PROVIDE PAINT RELATED CAULKING AND ACT-1 ARMSTRONG CW-6 NORTH SEA MATTE LAM COLUMN WRAP CPT-4 MFR:SHAW CARPET CPT-5 MFR:SHAW CARPET K. PAINT CONTRACTOR TO PROVIDE"TOUCH-UP"AFTER FIXTURE ITEM#6YLP7 FOR 6X6 STRUCTURAL COLUMN STYLE:AT&T 800Y7/STEP FORWARD 123/INNOVATE INSTALLATION. SERIES: DUNE STYLE:80 MODEL# 2 COLOR:STERLING#31557 COLOR:75597/MERGE SIZE: 2 X 2 SIZE:2'-0"X 2'-0" QUARTER TURNED SIZE:2'-•0"X 2'-0"QUARTER TURNED L. ALL FLOORING TRANSITIONS ARE TO BE FURNISHED AND COLOR: WHITE CONTACT:MARK LAW 770-241-1345 CONTACT:MARK LAW 770-241-1345 INSTALLED BY FLOORING CONTRACTOR. MARK.LAW SHAWINC.COM GRID COLOR: WHITE CW-8 NORTH SEA MATTE LAM COLUMN WRAP WALK OFF MAT, ENTRY MARK.L�AW@SHAWINC.COM FOH CARPET M. PAINT FINISH TYPES SEE FINISH LEGEND DESCRIPTIONS. CONTACT: COLUMN W.W.GRAINGER, INC FOR 8X8 STRUCTURAL RB-1 SHAW 4"COVE BASE(ROLL) ` FLAME SPREAD AND SMOKE DEVELOPMENT N. INSTALL FRP-1 WAINSCOT TO 4'-0"AFF ON ALL WALLS OF -806RAIN P RESTROOM, 100%GLUED BACK. NOTE: S AI S FLOOR STYLE:#148vs REQUIREMENTS FOR ALL INTERIOR FINISHES NOTE:SALES FLOOR CEILING COLOR NAME:GREIGE;COLOR:#560 `� CONTACT: MARK LAW 770-241-1345 � '�_ _ INTERIOR EXIT STAIRWAYS AND CLASS A O. GC TO PROVIDE LEVEL 5 GRADE FINISH ON ALL DRYWALL PARTITIONS IN RETAIL SPACE. DRAWN BY: M H VCT-1 ARMSTRONG CG-1 RETAIL SPECIALTY,INC CONTACT: DAN HICKEY MARK.LAW@SHAWINC.COM RAMPS AND EXIT PASSGEWAYS FLAME SPREAD INDEX 0-25 STANDARD EXCELON IMPERIAL TEXTURE 18GA STAINLESS STEEL WWW.RSIHO.COM SMOKE DEVELOPED INDEX 0-450 NOTALL ITEMS ON FINISH LEGEND USED. COLOR:STERLING#51904 COLOR:430 GRADE#4 SATIN FRP-1 MARLITE x 8/8/2021 CO12"NTACT. 1/8" SIZE: 1"X 1"X 4'-0 MODEL: P100,COLOR:WHITE,PEBBLE CONTACT: MARK LAW .COM 1-1345 SALES FLOOR EXPOSED CORNERS SIZE:3/32 X 4-0 X 8-0" CORRIDORS AND ENCLOSURE FOR CLASS B BOHMAR& AW ROOM FLOORING 800-835-4110 EXIT ACCESS STAIRWAYS AND FLAME SPREAD INDEX 26-75 BOH&RESTROOM FLOORING WWW.PARKLANDPLASTICS.COM RAMPS SMOKE DEVELOPED INDEX 0-450 SCALE: SEE PLAN BACK OF HOUSE AREAAS INDICATED ON A103, INCLUDE COLOR F..N W y MATCHED TRIMS AND CORNER GUARDS Op P-5 BENJAMIN MOORE P-12 BENJAMIN MOORE P-14 BENJAMIN MOORE ROOMS AND ENCLOSED SPACES CLASS C "HORIZON"#OC-53 "TORONTO BLUE"#2060-40 "THUNDER CLOUD"#2124-40 FLAME SPREAD INDEX 76-200 �?. EGGSHELL ON: FOH:WATERFALL FIXTURES,STOREFRONT EGGSHELL ON FOH ENTERTAINMENT WALL EGGSHELL ON FOH LOGO WALL SMOKE DEVELOPED INDEX 0-450 �' _ w SHEET NO: r 6 s Z m ■ BOH:ALL WALLS SEMI-GLOSS ON:FOH DOORS&FRAMES SEMI-GLOSS ON: FOH DOORS&FRAMES Y SEMI-GLOSS ON: FOH&BOH DOORS&FRAMES 877-623-8484 ATT#113572 877-623-8484 ATT#113572 877-623-8484 ATT#113572 BF-1 ALL INTERIOR FINISHES MEET FLAME SPREAD AND SMOKE � #TEG- T BLACK OUT FILM DEVELOPMENT CRITERIA 071 800E443-6776 OFESS INSTALLED ON THE INTERIOR SIDE OF GLAZING FLOOR PLAN GENERAL NOTES ; A. GC TO PROVIDE ALL WIRING IN FULL COMPLIANCE WITH THE MOST CURRENT AT&T IT STANDARDS, RFP V2.5 OR LATER. 1 , B. ELECTRICAL INFORMATION SHOWN FOR REFERENCE ONLY.REFERENCE M ELECTRICAL DRAWINGS FOR ENGINEERING DESIGN INFORMATION. Design Services C. DATA OUTLET INFORMATION SHOWN FOR LOCATION REFERENCE ONLY. NO TRENCHING WORK FOR THIS PROJECT REFERENCE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. CONDUIT SHOWN FOR REFERENCE ONLY. THIS PROJECT WILL D. PROVIDE PULL STRINGS IN ALL VOICE/DATA OUTLET CONDUIT. WWW.mchdesignseryiceS.com USE FLAT WIRE_ INSTEAD OF CONDUIT. SEE ELECTRICAL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E. ALL FACEPLATES,PLUG AND SWITCHES SHOULD BE WHITE.THEY SHOULD NOT phone:� BE PAINTED. (631)298-2250 DRAWINGS FOR MORE INFORMATION. 5' 10 1/2" F. WI-FI SYSTEM(EQUIPMENT PROVIDED BY AT&T)REQUIRES A POA(POWER OVER email: ETHERNET) POINT, michael@mchdesignservices.com — 5''-5 1/2" 5'-5 112" I POINT O BE LOCATED ON THE CEILING NEAR THE MIDDLE OF THE STORE.POA @ 72"AFF 1'•8" 3/4"AND 1"CONDUIT TO EXTEND — — — _ — — — — — I TO EXTEND TO THE WI-FI EQUIPMENT LOCATION IN BOH. ABOVE CEILING WITHIN WALL 1�8- 6- (2 ) 18" 8" 18" (2D) 18" G• CONTRACTOR TO PROVIDE LABELING FOR THE DUAL SWITCHED/NON-SWITCHED F4A I ELECTRICAL OUTLETS BEHIND THE MWU'S. 18" 1 18" NOTES: ' F4A 1. INSOUTLETS TALL LETIGL DUPLEX LEARNIELECTRNG CAL H. ANY DEALER-PROVIDED SECURITY EQUIPMENT TO BE WHITE OR SILVER COLOR OUTLETS FARING LEARNING _ �Q F4A C�F4A ONLY,NOT BLACK. BCW-LRG 1T �— 4D - 1T 4D TABLES E ASINGLE 20AMP I IT '7 1 HE I F4 10 E H H T - �� HET - 61 H H DEDICATED CIRCUIT.DO NOT INCLUDE ANY OTHER ELECTRICAL FLOOR TRENCH OUTLETSON THIS CIRCUIT. I J. ANY CODE REQUIRED ALARM OR EMERGENCY LIGHTING DEVICES SHALL BE e � 2"CONDUIT STUB-UP BEHIND FIXTURE 2. WHEN LEARNING TABLES ARE 5 LOCATED ABOVE 8'AFF. � FO CONDUIT / OUTSIDE OF WALL), I I 7 (2D) (2D) O (2D) O USED AS A TEMPORARILY POS j� FOR POWER FLUSH WITH CONCRETE STATION,THE 2"CONDUIT SHOWN , I I 3 1"CONDUIT - FLOOR _ e® _V® IS TO PROVIDE THE REQUIRED LJ HDMI AND USB CABLES,AND I— --r$ FOR DATA — l _ (2D) (2D) AMPLIFIERS CONNECTION FROM I I O I 4D) 18" I FLOOR PLAN KEY NOTES X 2"CONDUIT FOR / ® / BACKWRAP TO THE LEARNING 2" HDMI,(2)USB - 3. Tfl�DMI AND USB CABLES,AND, F4A F4A AMPLIFIERS SHALL BE ORDERED 1 11a'af1Ci) n i' �D) 9 � THROUGH GRAINGERAS I �V 10 I 1O EXISTING IT RACK RELOCATED IN BACK OF HOUSE AREA.SEE ELECTRICAL REQUIRED. �' DRAWINGS FOR MORE INFORMATION 4. WIREMOLD"RFB4E"FLOOR BOX 4 � (2D) / WITH"2 HUB ACCESSORY"AND I 7 2 2 O i i" "6CTBKTR"COVER PLATE,CAN BE I FLAT WIRE. ♦® - \ _ ^"� SUBSTITUTED IN PLACE OF i SPECIFIED FKLOOR BOX-1 WHEN 11 HE H H H HE AVAILABLETHE 881RC4ATCBK IF H HE , I O FLAT WIRE OUTLET: 1 DUPLEX AND 2 DATA BOX IS AVAILABLE. I F4A F4A F A F4A FLOOR BOX-1 5. WHEN FLOOR BOX-1 IS , SUBSTITUTED,2"CONDUIT SHALL BE F4A F4A F4A 8- , 4 FLAT WIRE OUTLET: 1 QUAD AND 2 DATA CONDUIT BOX TUB-UP NEXT TO CONNECTED TO2"HUB AT NEW I i Z-� 6 2 ( D+ T) 8„ (4D+a 13 _ _ 6 _ _ 6_ FLOOR BOX FLOOR BOX AND NOT STUB UP CV I I I O PROVIDE A 2"CONDUIT FROM TELEPHONE BACKBOARD TO ROOF FOR FUTURE T-6" T-6" _ 1 2. 18 „ - „ 1D) ROOF INSTALLED DEVICES(SATELLITE DISH, MUZAK, ETC.).CONDUIT SHALL BE )7 3 8" 8 1 g' 18' 18 -18' 11 — 2D 18— �OF BCW I - - - - - - - - _ - - - - - -- - - - I STUBBED UP ON ROOF AND CAPPED OFF.CAULK AND SEAL ALL PENETRATIONS AS REQUIRED.ROOF PENETRATION WORK SHALL BE PERFORMED BY LANDLORD'S ROOFER OR ONE APPROVED BY LANDLORD.LOCATION TO BE _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ — _ - - - _ - - - _ - - - - - - - _ — _ - - - _ — _ _ J COORDINATED WITH DEALER OR DEALER GC. O PROVIDE DUAL BRANCH CIRCUIT FOURPLEX RECEPTACLE;2 OUTLETS SWITCHED(CONTROL FIXTURE LIGHTING),2 OUTLETS HOT-PROVIDE BLACK FLOOR PLAN - ELECTRICAL * ADHESIVE LABEL WITH 1/4"LETTERING INDICATING"SWITCHED FOR LTG" SMOKE,CO DETECTORS AND EMERGENCY LIGHTING TO CODE ADHERED TO THE HALF OF THE FOURPLEX PROVIDING POWER TO SCALE: 1/4" = V-0° LOCATION TO BE DETERMINED IN FIELD AT TIME OF CONSTRUCTION SWITCHED LIGHTING.CONNECT TO MAIN SWITCH BANK LOCATED AS PER RCP. OF BCW O 5'-101/2 EC TO PULL COAX FROM IT RACK TO WALL.ALSO PULL COAX FROM SATELLITE TO IT RACK. LET FOR D GRAPHIC TO B 1 DATA PORT IN CEILING FOR SHOPPERTRAK,FURNISHED AND INSTALLED BY OUTLET FOR G ID GRAPHIC LIGHTING,TO 8E NIGHT LIGHT OTHERS.CENTER OVER ENTRY DOOR. -- -- 90 1 DUPLEX IN CEILING ABOVE THE STOREFRONT FOR"OPEN"SIGNAGE. �..� 10 EC TO PROVIDE DATA BOX AND CONDUIT WITH PULL STRING BACK TO IT RACK O 5'-5 1/2" 5'-5 1/2" LOCATION LOW-VOLTAGE CABLING. N SCHEDULE 11 DEDICATED POWER CONNECTION FOR HAND DRYER AT 51"AFF M i.i.r ON 1.4 w - -- _ 12 DEDICATED OUTLET FOR PRINTER. F�+i COUNT MARK LAMP DESCRIPTION MFR CATALOG NUMBER MOUNTING METHOD O -' 13 DEDICATED 20 AMP CIRCUIT FOR THE ELECTRICAL BEHIND BACKWRAP. O ^ - CANOPY MOUNTED AMERLUX HORNET HIGH POWER --_ - 21W LED FLOOD(28%%D)ACCENT LIGHT,COLOR TEMP SUSPENDED ON CEILING 14 F4A AMERLUX HORN ET-HP-21-LED-E-ST-C-1 20-FL-2700 AMERLUX 270),LOCKING TILT AND ROTATION,ON-OFF SWITCH, FINISH FLOOR COIAPLETE DIE-CAST CONSTRUCTION WITH V ELECTRONIC CONSTANT CURRENT LED DRIVER, z POWDER COAT PAINT SILVER TEXTURE FINISH. 4 DAATA RR1 TELEPHONE,4 POWER CENTER LIGHT AS CLOSE AS POSSIBLE ON MWU. ~ NOTE: ~� ALL ELECTRICAL OUTLETS FOR THE BACKWRAP FIXTURE ARE TO BE RECESSED I N ON A SINGLE 20 AMP DEDICATED CIRCUIT.DO NOT INCLUDE ANY 8 H LED 2'X 4'LED FLAT PANEL LITHONIA EPANL 24 40L 40K OTHER ELECTRICAL OUTLETS ON THIS CIRCUIT. CEILING GRID SAME AS TYPE'H'EXCEPT WITH EMERGENCY RECESSED IN REFLECTED CEILING PLAN LEGEND_ L _ 5 HE LED BATTERY PACK;PROVIDE REMOTE TEST SWITCH LITHONIA EPANL 24 40LHE 40K CEILING GRID r IF REQUIRED BY LOCAL CODE 2'X T SUPPLY DIFFUSER CEILING TYPE(SEE A103) RCP GENERAL NOTES ALL FIXTURES WITH EMERGENCY BATTERY BACK-UP SHALL BE CAPABLE OF ILLUMINATING LAMPS FOR A MINIMUM OF 90 MIN. *EMERGENCY BALLASTS FOR FLOURESCENT LAMPS SHALL BE CAPABLE OF PRODUCING 1400 LUMENS. ACT-1 *EMERGENCY BALLASTS ARE SHIPPED SEPARATELY AND SHALL BE FIELD INSTALLED. 10'-6"AFF A. LIGHT SWITCHES TO BE MOUNTED AT 48"AFF,LINO. FOR ALL LIGHT FIXTURE ORDERS,CONTACT GRAINGER: 404-806-8288 2'X 2'RETURN B. SEE SHEETA103 FOR FINISH SCHEDULE AND ACOUSTICAL CEILING TILE(ACT) ATT@GRAINGER.COM CEILING HEIGHT INFORMATION. C. TRACK LIGHT HEAD TO BE CENTERED ON FIXTURE BELOW,GC TO AIM LIGHT. NEW ACCENT LIGHT FIXUTRE D. GC TO PROVIDE PLYWOOD BACKER IFOR EACH ENTERTAINMENT WALL SPEAKER. PROVIDE ONE OF THE 2 SIZES:24"X 24"X 1/2"OR 6"X 24"X 1/2". E. SPEAKER CAE?LES SHALL BE INSTALLED WITH 10 FEET OF ADDITIONAL LENGTH AT NEW ZX 4' LIGHT FIXTURE SPEAKER ENDS FOR ADJUSTMENT DURING TERMINATION.SPEAKER CABLES MUST BE PULLED DIRECTLYABOVE THE IT RACK AND EXTEND TO FINISHED FLOOR. F. SEE SHEET A301 FOR LED STRIP LIGHT DETAILS. TYPICAL OUTLET CONFIGURATION DETAILS RCPKEY NOTES PROVIDE CONDUIT FROM AATV (TV WALL): ACCESSIBLE CEILING TO COAX MWU' 2'X 4'CEILING GRID AND TILE EXISTING CEILING TO REMAIN TERMINATIONS. ROUTE COAX CABLING TO MDF ROOM. 2 NEW CEILING GRID AND TILE IN THIS SPACE NIGHT® o 0) 0 ED LIGHT o 0 NIGHT o � O O LIGHT o O O 3 PREFERRED LOCATION FOR MAIN LIGHTING SWITCH BANK.ALL INTERIOR (2D) (2D) 0 0 " 0 (2D) o LIGHTS TC,TERMINATE HERE. ® EXISTING EXIT LIGHT (2)GROUPS OF: (1)COAX AND(2)DATA/QUAD RECEPTACLE+ E DATA FOR NIGHT LIGHT DUPLEX RECEPTACLE EVERY OTHER MWU NON- SWITCHED FOR POWER / COMMUNICATIONS SWITCHED DISPLAY LIGHTING C/)-] LIGHT SWITCH REFERENCE LEGEND BCW (BACKWRAP)AND PTR (PRINTER): IP (I-PHONE) THERMOSTAT 'MEP DRAWINGS SHALL GOVERN WALL DUPLEX OUTLET ® FLOOR DATA OUTLET 8 b0A 6 o&bo o o o � �12)) 00 o Q 0 o o Q � ,(2D) R RELOCATED EXISTING FIXTURE DRAWN BY:" o E EXISTING TO REMAIN O 0 WALL QUAD OUTLET ® FLOOR DUPLEX OUTLET � I"11 I (1)SWITCHED DUPLEX RECEPTACLE/(2)DATA CO-I WALL COAXIAL CABLE OUTLET ® FLOOR QUAD OUTLET (4D+1T) DUPLEX RECEPTACLE (1)DUPLNTEREX RECEPTACLE FOR o/o/�O�1 i FOR (1)QUAD RECEPTACLE/(4)DATA O O WALL DATA OUTLET ® FLOOR BOX-1 INTEGRATED /(1)TELEPHONE FOR PRINTER WALL TELEPHONE OUTLETTO-I THERMOSTAT LIGHTING AND ADDITIONAL IT EQUIPMENT SCALE: SEE PLAN �0 N E W 1'0 SHEET NO: LU mZ .,.-� �Fo 072, o pRO SS` �P