Loading...
HomeMy WebLinkAbout45268-Z 019, Town Town of Southold 6/11/2021 P.O.Box 1179 0 o _ 53095 Main Rd 4, �a Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42078 Date: 6/11/2021 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 10095 Route 25,Mattituck SCTM#: 473889 Sec/Block/Lot: 142.-1-26 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/21/2020 pursuant to which Building Permit No. 45268 dated 10/1/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alter existing commercial unit to a medical office for Stony Brook Community Medical as applied for. The certificate is issued to Mattituck Plaza LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45268 4/9/21 & 5/10/21 PLUMBERS CERTIFICATION DATED 6/1/2021 Jo ambale-S-4 th riz gnature TOWN OF SOUTHOLD (044'f,o, BUILDING DEPARTMENT 5. TOWN CLERK'S OFFICE *_ g�-�, � 4'? SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45268 Date: 10/1/2020 Permission is hereby granted to: Mattituck Plaza LLC PO BOX 77 Mattituck, NY 11952 To: alter existing commercial unit to a medical office as,applied for. At premises located at: 10095 Route 25, Mattituck SCTM # 473889 Sec/Block/Lot# 142.-1-26 Pursuant to application dated 7/22/2020 and approved by the Building Inspector. To expire on 4/2/2022. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $2,221.20 CO -COMMERCIAL $50.00 Total: $2,271.20 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,,building and unusual,natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. ,Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 117 112-02-0 New Construction: Old or Pre-existing Building: \/ (check one) Location of Property: [(--)09!5 MAIN ROAD MATT IT U C K House No. Street Hamlet Owner or Owners of Property: ALAN C^KD I N A L F- - MATT I T UCK. PLAZA L L C- Suffolk County Tax Map No 1000, Section 142. Block 01 Lot 2(.0 Subdivision - Filed Map. Lot: Permit No. �2 Date of Permit. Applicant: MARK M A;N Cl N 1 - M A NCI N I ARCH ITECTUr-E Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: TemporaCertificate Final Certificate: (check one) Fee Submitted: $ / pplicant Signature Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, WnIO. C residing at 13 8 4 I)Ud (Print property owner's name) � Lu��e.�L do hereby authorize Mark Mancini - (Agent) Mancini Mui Architecture to apply on my behalf to the ` Southold Building Department. NO ( er's Signature) (Date) (Print Owner's Name) BARBARA MCKBNNON Notaly Public-State of New York No.01 MC6101870 QUalified in Suffolk County MY omission lExpires kllcv. 17,202 r pF SO(/r�®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.devlina-town.southold.n us Southold,NY 11971-0959 ® �® y' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To Mattituck Plaza LLC Address: 10095 Route 25 city Mattituck st: NY zip: 11952 Budding Permit#: 45268 Section: 142 Block: 1 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Mannorville Electric License No: 51495ME SITE DETAILS Office Use Only Residential Indoor X Basement Service X Commerical X Outdoor X 1 st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures Bath Exhaust Fan Service 3 ph X Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 2 A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment- Notes: Made Services for Units 1 & 2 Safe for Re- Energizing Inspector Signature: C Date: April 9, 2021 S.Devlin-Cert Electrical Compliance Form.xls sov��®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 ® �� sean.devlinta'�town.southold.ny.us COUNTd,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mattituck Plaza LLC Address: 10095 Route 25 city-Mattituck st: NY zip: 11952 Budding Permit# 45268 Section: 142 Block: 1 Lot: 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA' Luminaire Electric Corp License No: 37665ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Commerical X Outdoor X 1st Floor X Pool New X Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 10$ Ceding Fixtures 2 Bath Exhaust Fan 6 Service 3 ph X Hot Water GFCI Recpt 5 Wall Fixtures Smoke Detectors 35 Main Panel A/C Condenser Single Recpt Recessed Fixtures 3 CO2 Detectors Sub Panel 1 A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO 4 Transformer UC Lights 2x2 LED 24 Emergency Fixturesli Time ClocksDisconnect Switches 33 2x4LED 55 Exit Fixtures Pump Other Equipment* Mini Split-1 Notes: Medical Office Inspector Signature: Date: May 10, 2021 S.Devlin-Cert Electrical Compliance Form(1).xls SOUTyolo Town Hall Annex -W- Telephone(631)765-1802 54375 Main Road jW jW Fax(631)765-9502 CA-) -I�c P.O.Box 1179 zz; -Q-z Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD "j JUN 2 2021 c6t r lf� CERTIFICATION Date: 60 Building Permit No. L4-'J D LO 8 Owner:-fi r. Br-00y, t'Cle-s1c-0j (Please print) Plumber: (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers Signature) Sworn to before me this day of June 20 Notary Public, 5o Vr--' County D RYAN A NE KERZNER St t Notary=Pub 11c State of New York No.OIKE6307741 Qualified S ff Qual fled in Suffolk County In M Corn m.Ex fres Jul 14,2022 1 FEB 2021BUILDING DEPARTMENT-Electrical Inspector* �fi TOWN.OF SOUTHOLD jT: jwn Hall Annex- 5437.5 Main Road - PO Box 1179 3 y e Southold, New York 11971-0959 a Telephone (631) 765A 802 - FAX (631) 765-9502 rocerr �sou#holdtown y gsy .tiseand southoldtownny:aov � . A -PLLCATI 'FQR ELtbtRICAL.`INSPECTION j 'ELECTRICIAN INFORMATION (Au Information Required) Date 2.11.21 company Name: LUminalre Electric Corp Name: MattrtueLC.Plaza Medical Of#Ice.` ....... . License No.: M3766 email kim@fumnairecorp.com .� Phone No: 631.345.9320 ✓.I.request an email c of Certificate of Compliance . a 16095 Rte 25 Mattituck' NY _ . , Address.: , JOB SITE .INFORMATION (Ail Inforrhaa... Rewired) Name:MAttituck.Plaza;Medicat.Office s Address: 10095 Rte 25 Mattltucka NY E cross.Street: Factory.Ave hone No ,631 345 9320 BIdg.Permit#:.4526 email kimCiumina recorp.com s Tak--Ma District: 1000 Section: laGk::....,.�. a � ...:...:... Lot}... BRIEF DESCRIPTION-OF WORK (Please.Print:Clearly) Check All ha APPIY� .: s Is�bb:read for iris ection?: . ✓� YES NO ✓� Rough In ❑Final Do;you need,a Temp Certificate?: []YES- .. t✓ NO Issued.On 2.11.21 - - Temp Fnforrriatiori: (AlLinfonnatiorr'required) Service Size 01 Ph ❑3 Ph Size`,. .. A #'M.,eters . _ _ :_.01d Meter# New Service El s' Reconnect-. 0:Underground QOverhead #Under round Laterals _2 . '.:.;H Frane_ . :.Pole:. _. _Vllork_done on Service?. Y N. D . ❑ Adiditional'Information: Electrical Inspection Form 2020.xlsx SO//l�°lo # TOWN OF SOUTHOLD "BUILDING DEPT. ; 765-1802 INSPECTIO-Nz [ ] 'FOUNDATION 1ST [ UGH PLBG. [ ] FOUNDATION 2ND [_ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ]` FINAL [ ] FIREPLACE & CHIMNEY- [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATIO [ ] PRE C/O REMARKS: DATE Or Oo 4-/ INSPECTOR - "/ SOpl�o # # TOWN OF SOUTHOLD BUILDING DEPT-. 765-1802 1 NSPEC ON [ `1 FOUNDATION 1 ST [ ROUGH PLBG. 1N-w**'� [ r UNDATION 2ND [ ] INSULATION/CAULKING AMING /STRAPPING [ ] FINAL [ ]. FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION f ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION" [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: hY\14 CA�� DATE ]YW 14 INSPECTOR rnsf SO # * TOWN OF SOUTHOLD BUILDING DEPT. �ycouto, 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ]" FIREPLACE & CHIMNEY " [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: oiJl� �c� DATE l ANSPECTOR I # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] OUGH PLBG. [ ] FOUNDATION 2ND [ INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [" ] FI E SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ FIRE RESISTANT PENETRATION [ ] ELECTRICAL-(ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 6-�-ktvc tUI vjv<GDY"' DATE INSPECTOR O��Of SOUTyo! /i/L Y , ZA * # TOWN OF SOUTHOLD BUILDING DEPT. `ycourm '' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING" [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: bvIi 2 a DATE 3112-,y Zo2 l INSPECTOR D3 OE SOUTgOIo # TOWN OF SOUTHOLD BUILDING DEPT. °y�nurm 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSUL-ATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE•SAFETY INSPECTION- [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS:. DATE INSPECTOR JAISOUIyO� TOWN OF 'SOUHOLD BUILDING DEPT. , °`y�ourm ' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ]- FOUNDATION 2ND [ ] INSULATION/CAULKING- [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION rl PRE C/O REMARKS: tc'L I N S( goy-eol\j Ve'- DATE INSPECTOR �%� Ll 5 /0 Oq 5 Of SO(/j�,� # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 : . INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: &Dj Cwt, ale DATE INSPECTOR ���~ lujif so Yd IZ Me— TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 04--r-r. flAZA INSPECTION I FOUNDATION 1ST ROUGH PL13G. FOUNDATION 2ND, -INSULATION/CAULKING FRAMING /STRAPPING FINAL FIREPLACE & CHIMNEY '[��FIRE SAFETY INSPECTION ' FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION f ELECTRICAL (ROUGH) ELECTRICAL (FINAL) I CODE VIOLATION PRE C/O REMARKS: - ,1;7�- Accivi-nvce Zi�r T- ,DATE 5_— le) INSPECTOR AP s-Zc� °�y OF SOUT�olo # # TOWN OF SOUTHOLD BUILDING DEPT. • cn765-1802 MRA INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [` s]. INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FI AL [ ] FIREPLACE`& CHIMNEY [ FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: ���l�/�CC � � � ► DATE _fd "2yZ r 1 NSPECTOR tf souryo * # -TOWN OF SOUTHOLD BUILDING DEPT. d' /moi✓ `ycou765-1802 INSPECTION [ ] FOUNDATIONA ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND : [ ] -1 SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ]` FIREPLACE & CHIMNEY [ FIRE°-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: Zee— el - ell� 0rVIAleo� DATEINSPECTOR ✓'V� SOF so(/T�, � o # TOWN OF SOUTHOLD BUILDING DEPT. `ycou765-1802 INS=PECTION [ ] FOUNDATION 1ST [ ] R GH PLBG. [ ] FOUNDATION 2ND [ ] SULATIOWCAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] -FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARK : a" b& ro6 eD, IAmc,",_�� (,*t4 DATE [0 INSPECTOR 1FIELD INSPECTION • • FOUNDATION t ROUGH FRAMING& PLUMBING 1p INSULATION PER N.Y. STATE ENERGY CODE L MA E�l�li����� • -' ice,<<'.�,..; ,, ,,_ ,;� I • o � a • . a� - - 11 _• VA • p ! E-21100 - ,� • i �� ,r�� i ` 1 Up in,WAMM � film Wx i � Go �J� TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health PF_N DI N C— SOUTHOLD,NY 11971 4 sets of Building Plans ✓ TEL: (631)765-1802 Planning Board approval FAX: (631) 765-9502 S �QSurvey ✓ Southoldtownny.gov PERMIT NO. 6< 00 Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application j� Flood Permit Examined (J ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved I t/ 20 O� Mail to: Disapproved a/c Phone: Expiration ,20 i aV— Building Inspector ' JU L 2 1 200 APPLICATION FOR BUILDING PERMIT WILDING DEPT Date J_U L-Y -7 -1"+i , 20 20 I' TOT + MOLD INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housin code,and a tions, and to admit authorized inspectors on premises and in building for necessary inspections. (S' nature of app ' ant or name,if a corporation) ZZZ MIDDLE GbUty-r1z-Y 20AP STE : 1Iq SM 1TRTOw N NY 11-78-7 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder ARU111GT Name of owner of premises ALAN CARPINALC - MATTITUCK PLAZA LLC (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 10095 MAIN ROPED MATTITUCK House Number Street Hamlet County Tax Map No. 1000 Section 142- Block 01 Lot 2ln Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy M 1=RCA NT I L 1✓ � bU S 1 N E SS USE b. Intended use and occupancy MEDICAL USE- 3. SE3. Nature of work(check which applicable):New Building Addition Alteration ✓ Repair Removal Demolition V Other Work (Description) 4. Estimated Cost! b 25, 000. O O Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units — Number of dwelling units on each floor If garage, number of cars — S7ONVl3ROOK 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. MEDIC-AL 7. Dimensions of existing structures, if any: Front 3Z) .( I Rear 3 2.3.3 I Depth I y I . I I Height 191 Number of Stories I Dimensions of same structure with alterations or additions: Front 321.Io I Rear 323.3 1 Depth 141 . 1 I Height -1-/– 191 Number of Stories 1 8. Dimensions of entire new construction: Front — Rear — Depth Height Number of Stories 9. Size of lot: Front Lo 4 to. 8 3 Rear (D(Dy•36 I Depth 513.3 5 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated GENERAL BUSINESS 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO ✓ 13. Will lot be re-graded?YES NO ✓Will excess fill be removed from premises?YES NO ✓ 136410 ATLAMIG SL D#IOy ; 14. Names of Owner of premises ALAN CARDI NALF--Address SACKSONVILLE FL32Z25Phone No. Name of Architect M ARK MAN C1 N I Address?-52('%1-T TOW M NVPLE NI rt@7 hone No (P 31- 919-01 O`l Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO ✓ * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) A.N G I 1-j I being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the A4:;LtN T / ;A �4t�c1� (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or ha performed the said work and to make and file this application; that all statements contained in this application are true to the best o is knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me th' 7 d y of Lt 2u AW—PEIFFER OTAR-Y.PUBLIC,STATE OF NEVE,YOkk, No:OI PF6375678 8olk County Public Ca` kPilms May.29.'20 Signature of Applicant �O�g0FF0�K�0 x Gyp BUILDING DEPARTMENT-Electrical Inspector rte„ x TOWN OF SOUTHOLD o1 • Town Hall Annex-54375 Main Road-PO Box 1179-Southold, NY 11971-0959 Telephone (631) 765-1802-FAX(631) 765-9502 Temporary Certificate # _5i Date tY 4V7 2021 Customer Name mk � 77 LA--Z_ r Electrician Name ,.OAnaryille C zZiY� Address J©cicq 5 aln &4veA Phone X031 L1614 67Eq e-mail e-mail p wl v 1 /e �r'Cl ago Phone License# -_g/Lj qS /ljr Size GV A Phase Overhead Underground #of Meters Remarks #of Underground Lateralsl 1 2 New "H" Frame or Pole H P Fire Reconnect Was work done on Service? Y N Flood Reconnect Old Meter#1 Service Reconnected Application for electrical service equipment is on file with the town of Southold.On the applicant's notification that this ins allation is complete,the town will conduct a premises inspection of the service equipment. This verification is valid for 90 days from the date above. Authorized by r V i r A I t { t ! FEB ?021 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD . y C* : - Town Hall Annex- 54375 Main Road - PO Box 1179 y 7+ ` Y r o sz ` Southold, New York 11971-0959 % p'� Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr southoldtownny.gov— seandO-southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail Information Required) Date: 2.11.21 Company Name: Luminaire Electric Corp Name: Mattituck Plaza Medical Office .License No.: ME37665 email: kim@luminairecorp.com Phone No: 631.345.9320 EI request an email copy of Certificate of Compliance V Address.: 10095 Rte 25, Mattituck, NY JOB SITE INFORMATION (All Information Required) Name: Mattituck Plaza Medical Office Address: 10095 Rte 25, Mattituck, NY Cross Street: Factory Ave Phone No.: 631.345.9320 Bldg.Permit#: 45268 email: kim@luminairecorp.com r Tax Map District: 1000 Section: Block: Lot: ( BRIEF DESCRIPTION OF WORK (Please Print Clearly) ReIn QQ C� a42 - M e rLk-c a'c_- 0 ► t "[ LS ' Check All That Apply: Is job ready for inspection?: EYES ❑NO ❑✓ Rough In ❑Final Do you need a Temp Certificate?: ❑YES ENO Issued On 2.11.21 Temp Information: (All information required) Service Size ❑1 Ph ❑3 Ph Size: A #Meters Old Meter# { ; ❑New Service ❑ Service Reconnect ❑ Underground ❑Overhead #Underground Laterals ❑1 ❑2 ❑H Frame Opole Work done on Service? ❑Y ❑N Additional Information: PAYMENT DUE WITH APPLICATION Electrical Inspection Form 2020.xlsx Liq " tl fOL . BUILDING DEPARTMENT-Electrical Inspector ggirl KCM G: TOWN OF sOUTHOLD Town Hall Annex-54375 Main Road- PO Box 1179 N - Southold, New York 11971-0959 oy • 0�� Telephone (631)765-1802-FAX(631)765-9502 ronerrCa�southoldtownny^ov seand�a southoldtownny.Qoy APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ail Information RequiE, D ate' Company Name: n or V l t Name: L �' Tf2. eemail:License No.: S J ���5-ryl L "Lag Address: 1 Phone No.: I y y 7 JOB SITE INFORMATION (All Information-Required) Name: a t�L- "IC16 �a7�- 1115 17 Address: /00 Q,? Cross Street: Phone No.: G31- 9� 9Y W Bldg.Permit#: 1017 email:f?1an52 fnakmafa .151DIn Tax Map District: 1000 Section:_ / 2 v _ Block: _ / Lot:_ BRIEF DESCRIPTION OF WORK(Please Print Clearly) Circle All That Apply: =. Is job ready for inspection?: Y Rough In Final Do you need a Temp Certificate?: Y �/ N Issued On,- Temp Information: (AII information required) v Service Size 1 Ph Size: �,-A #Meters Dom Id Meter# New Service-Fire Reconnect-Flood Reconnect-Service Reconnected-Underground-Overhead' �`7 �= Underground Laterals 1 2 H Frame Pol ' Work done on Service? Y N—! Additional Information: r k l l: ^ PAYMENT DUE WITH APPLICATION �I Request for Inspection Fonn.xIs 41 �� . - i I MANCINI U - i 1 ARCHITECTURE CTU r MAY 2 5 2021 222 Middle Country Rd, Suite 314, Smithtown, New York 11787 IT P• (631)979-0104 F (631)979-3445 E info(a-manciniarchitecture.com �' Transmittal Letter T0: Town of Southold Project: 10095 Main Road, Mattituck Building Department Project No.: Attn: Amanda Nunemaker Date: May 24th,2021 We Transmit: [ ] herewith [ ]under separate cover via [ ]in accordance with your request For Your: [x]approval [ ]distribution to parties [ ]information [ ]review and comment [x]record [ ]use [ ]signature [ ] The Following: [x]drawings [ ]shop drawing prints [ ]samples [ ]product literature [ ]shop drawing reproducibles [ ]specifications [ ]change order [ ]documents [ ] Copies Date Rev. No. Description (4) 5/24/21 1 Amended Plans Remarks: Copies T0: Signed Michelle Misciagno i �I ROY K REISSIG P E `1 MAY 30 2020 S' 9 BETHANY CEMETERY 03 TOP SOIL(PT) JV6I I]'S0"E � 66136' 1 7'BROWN FINE SILTY SANG(SM) i 1 5 PALE BROWN SAND(SP) b I uu OUTFALL 6 BEiwwl'CEMETFE! NUE I OUTFALL p 1 O ! 2 5 DARK BROWN SAND k GRAVEL(SP) 1EOION A NO CHANGE ! rn Pg EXISTING SANITARY SYSTEM 1 ! NO CHANGE RETAINING WALL 150 30 BROWN SAND @GRAVEL(SP) Mx+ 0\ 0 07CY 11 � HIGHEST EXPECTED G. ELEV 38 ! `J lJ lJ GROUNDWATER TEDELEV 2 9 N i I O O�UT�F�A�Ii S 2 '! R0N0 ! O 1N 60'LIGHT BROWN WET SAND(SP) i A I I5TIN0 WATER 1111111 f 1 KEY MAP N M la 3t ! EXISTING WATER SE-11 D 7 I ! I SUBJECT BUILDING AREA UNDER THIS APPLICATION I f ! ! USE MEDICAL-4,976 SF i ! Q ! t I � n ! 1,200 GAL � ,! n i SOIL BEPTICFARINGT PRECAST I FFIC BORING � ! A4 1 ELEV 11 9 19 18 7© 16 Q I .1 CLEAN-OUT I PRECAST CONCRETE 1 ® LEACHING GALLEY ho 10 O5 OB , I l 05 •! 1 OUTFALLS 5° o ! NO CHANGE O !1 OUTF 4 (y ! C C 0 1 O j °°NO�t` '!, SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES O �i APPROVAL OF CONSTRUCTED WORKS O� O r, O OO !�! a DATE 2/9/2021 H.S. Rif. No. C-20-0198 i OO O !! The sewage disposal and water supply fara'itles ! at this location have been inspected and/or i EXIST G STORM DRAT O 'NO GE �-��� 6a6 B9 certified by this department or other agencies O� and found to be satisfactory el O 0014600 -Sag5790." \, CRAIG KNEPPER, P.E., CHIEF ;a 25) OFFICE OF WASTEWATER MANAGEMENT *j SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES LOT AREA = 381,023.21 SF !!', MAI IJ RU AD \l� OR 8.747 ACRES �Lo 1.� sag67's�x A SEWAGE FLOW CALCULATIONS ISBU LSTORE SF x FLOW RATE DENSITY KRCHEN/GRAY HYDRAULIC GPD CPD GPD GPD I BUILDING"A 1 REAL ESTATE 400 x 0 06 24 24 - 20 - 019 (9 2 STARBUCKS 1,500 x 003+012 45 180 225 3 RENEE'S 10,000 x 003 300 300 4 WALGREENS 12,aoo x o03 iso iso STRUCTURE DISTANCE FROM 5 DRY CLEANERS 1,000 x 003 30 30 6 CHINESES FOOD 1,300 x 003+012 39 156 195 ALLOWABLE SANITARY FLOW NUMBER "A" "B' _ 7 CINEMA 1,255 SEATS x 3 3,795 3,795 a LUCHARITOS BURRITO BAR 800 x 003+012 24 96 120 GROUNDWATER ER W FOR EM ZONE Iv 9 WINE STORE 2,200 x 003 65 66 ALLOWABLE FLOW FOR SITE 600 GPD/ACRE ST 1,26'0 GAL 1 l0' 45' 10 AT&T 2,500 % 003 75 75 (600 GPD/ACRE)X(8 747 ACRES)-5248 GPD SEPTIC TANK I1 AT&T 400 x 006 24 24 SfNRAR'Y DENSITY REFERENCE!CIO-99-0014-8815 GPD SANITARY DENSITY REQUIRED FOR THIS PROJECT=7,328 GPD 12 BAGEL STORE 1,390 x 003+012 42 167 209 13 CARDINALE REALTY MANAGEMENT 1.700x 005 102 102 LG 1 LEACHING GALLEY 123' 38' MATTITUCK PLAZA LLC 21 VACANT-UNUSED-UNRENTED 6,800 x 000 0 0 SEWAGE DISPOSAL SYSTEM BUILDING"Er LG 2 LEACHI14G GALLEY 122' 34' SCTM # 1000-142-1 -26 r 14 NORTH FORK OPTICAL 1,500 x 010 150 150 SEPTIC TANK. I, 15 AMERICAN GRILL 40 SEATS x 30 400 800 LWO REOUIRED a98 GPD X 2 DAYS =996 GPO PRPME (1)8X X 4 EFFECINE DEPTH =12DO OPD LG 3 LEACHING GALLEY 133' 30' _ 16 RENEE'S FURNRURE 1,800 x 003 54 54 OF NEW DANIEL Tx IE R FALASCO, P E , P C 17 VEft20N 800 x 003 24 24 LFAGHINc POOLS. iI SF' r lJ t'11V ILL 18 MATRTUCK MARKETPLACE 32,325 x 003+002 970 647 7,617 REQUIRED 49B GPD/15 GPO/SF =332 SF LG 4 LEACHING GALLEY 132' 24' �P�-` `� 4- 19 MICHELANGELO RESTAURANT 75 SEATS x 30 750 1 500 2,250 PROVIDE (6)LWHWG GALLEYS 25 EFFECINE DEPTH =397 SF CONSULTING ENGINEER 20 MEDICAL 4,976 x 010 418 LG 5 LEACHING GALLEY 144' 24' 94 STEUBEN BLVD NESCONSET NY 11767 TOTAL 7 772 772 3,Sdfi 11,318 f• '� (516)317-7209 ALLOWED 8815 �O °055990 LG 6 LEACHING GALLEY 143' 17 P DATc 11-20-20 sALi.am ORAwINc NO ' ROFE5510NP� I SOTJTHOLD TOWN FIRE MARSHAL NOTES i JOB: STONY BROOK MEDICINE DATE:-7/24/2020 j LOCATION: Matt. Shopping Plaza 10095 Main Rd. Matt. S/B/L: 142-1-26 Scope of Work: Interior alterations to 3 suites. Total work area=4980 ft2 General: Occupancy Type-B Construction-2-B? j Occupant Load-4980/ 100=49.8 , I Fire Protection: Existing sprinkler system r F/A plans to follow on separate permit. 2 FE Shown-travel dist<75'throughout. - OK Egress: Exits Req-2 Exits Provided- 3 Max travel dist allowed 300' (Sprinklered)Actual max travel dist- 104' - OK { Comments/ 1. Separation between proposed medical office and Michelangelo's restaurant? Concerns: . I ' I 200727StonyBrookMedicine_MattPlaza Page y CNECKMATv ' W. SEC R!T- Y' 65 JOHN STREET, BABYLON, NY 11702 PHONE: (631) 669-3303 FAX: (631) 669-7259 www.CheckmateSecurity.com Licensed by the NYS Department of State Lic.No. 12000017610 Stony Brook Medicine 10095 Main Road Mattituck, NY 11952 Amendment to permit # 45268 — Fire Alarm Plan Richard F. Denner Checkmate Security Systems, Inc. i i ' A JAN 1 2 2021 - t BATTERY CALCULATIONS FOR:F-1 Stony Brook Medicine,10095 Main Road,Mattituck CALCULATION TABLE Standby Alarm Total Draw(Amps) 0.323050 1699150 Time Factor(Hours) 24 000000 0.083333 Product of Time and Total Draw 7.753200 0.141596 20%Deterioration Factor 1.550640 0.028319 Subtotal 9.303840 0169915 Minimum Battery Size Required 9.473755 Note:See list below for the manufacturer,model number and quantity of the batteries to be supplied. Type Manufacturer Model Device Mount Standby Alarm F-1 F-1 Standby F-1 Alarm In�FCglltteCtiAn 1 HVAC N1DtpTaStatter ,.' " =; U �Q :3 "f! 'j New F.B.O. F.B.O Interconnection Sprinkler Valve Supervisory Switch 0 0 2 0 0 Nein, 'F>B:O. ` FtB,t� ,,, Inte[connection)SprtnitlerlNaterFtovu _ �" - U: 0 '2�_",�'-_:��;'... ;b< -'e<<' 0 New Honeywell]Farenhyt IDP-MONITOR lAddressable Input Module Any 0.00035 0000351 3 0.00105 0.00105 N�wv.,« iia"neyw 7l;F tenHyt ,IDP=P IOTO x Return'fu '©et,64.R04uires t NW-&Sart]1a Tube „s f Ou, �',.°, �Ad.'0603 0, _ � Rg' - :,,...,._. x��� g 0065 Vis'„3= 0.0190 New Honeywell I Farenhyt IDP-PULL-SA Pull Station I Single Action Wall 000035 0.00035 4 0.0014 0.0014 rNew Honejw if(,Fa�enbyt.' IDP=RELAYa,�,.a,c Addressable'output-Module`(Relay)�” _r ,Any, 0.0003 , 0.003, Honeywell]Farenhyt IFP-300 FACP I Det.159;Mod:159;Output•4;Bat 35Ah Wall 0.19 025 1 0.19 0.25 HorleyyYe(t,(;Farenhy' RA-10011 AdditionalDrava=,OrSBUS« s Q;,, :; O:A= 0:1 s�1N�.l 'y0:1 Honeywell l Farenhyt RA-1000 Annunciator Wall 0.02 0 025 1 0 02 0025, N�wv` ` .` toneywelil F?ai'entijt" RA10DZ��-I'; �`^ Re�notefampa R, ., -AoY �0 �a�0.012 fEh`�3 ,:.=m- 0 r O,OBf New Honeywell]Farenhyt IDP-PHOTO-W Smoke Detectors Base-B300-6 Ceiling _ 0.0002 00045 32 0.0064 0.144 New Honey] ell eFarentSyt,=IOF=., ��CO,-W 5moke'CO,FI5Me HeatDetecto�J;' o�undeF,6ase:82005-WHI , Cgiling 0.0003 ;__4.OpA5;;x 4= x; 0.IM3 ;r �OI318 New Honeywell]Farenhyt B20OS-WH Additional Draw for Non Resettable Power 0 0.035 4 0 0.14 New` Honeyi�e)lJFaeiihyt'w 82flUS=O{ .z '; AudibieBase)Au ibfaBase`a 85-dBA Bas a 0.6003: 4O.naoa x �,$ New Power Sonic PS-12120 Battery I 12Ah Internal 0 0 2 0 0 t9esn`'' .5ysterra-5z�asoK^<� hft .��"; tireatheipnA Audibliii e(Set o:75cd � "' Watl "'„` �° ,`,0 76 �"� � l-* New System Sensor PC2WL Audible Strobe I Set to*15cd Ceding 0 0 071 2 0 a 0.142 New Sysfein`Sens6,' _ PC2WL,,-""` << n 3Ab ;SetCelsng p , 2b New System Sensor PC2WL Audible Strobe]Set to-95cd Ceiling 0 0165 1 0 0,165 gY4tei.4ensar, .;,,, 'sC1M) tti,,. 5tro Sit to:1 cd',;` a , ua s;, `Cuing air n oi39i 8, 0' O,ia? , JA N 1 2 2021 `_w Honeywell I Farenhyt Series Intelligent Fire Alarm Control Panel IFP-300 IFP-300B [he IFP-300(red)and IFP-300B(black)are intelligent analog/addressable Fire Alarm Control Panels(FACP) The basic IFP-300 panel contains I' one built in signaling tine circuit(SLC),which can support 159 IDP/SK sensors and 159 IDP/SK modules or 127 SD devices per loop Additional Sl C loops can be added using the model 6815 Sl__C expander for System Sensor devices to increase the overall point capacity to a maximum of 300 points per panel,or model5815XL for Hochiki devices to increase the overall point capacity to a maximum of 254 points per panel IFP-300 has the interconnection capability for up to 32 panels The system has two modes of operation,multiple panels covering one larger building,or multiple independent buildings To network panels together IFP-300B use the SK-NIC network interface card Copper wire or fiber op is cable panel connectivity can be used within the same networked system. IFP-300 has a built-in dual phone line,digital alarm communicator/ transmitter (DACT),IP or optional cellular technologies,Form C trouble relay,and two programmable Form C relays IFP-300 has powerful features such as detector sensitivity,day/night thresholds,drift compensation,pre-trouble maintenance alert,and calibration trouble alert The IFP-300 supports a variety of devices,including RA- 2000,RA-1000 or RA-100 remote annunciator,5824 serial/ parallel printer interface module(for printing system reports), FEATURES & BENFFI TS • Network support for - IFP-300 Lan be e Network card allows m JumpStart Supports Class B up to 32 Sites surface or flush copper network AutoProgrammrng' (Style 4)and Class A • Burtt-111 Support-or up mounted connection with a feature for easy (Style 6 or Styte 7 to 159 IDP/SK m Built-in USB interface multi-mode or programming configuration for SLC detectors and 159 for programming single-made fiber m Supports up tc four and SBUS IDP/SK modules or connection option SWIFTwiretess ® t rrmwar e can be Built in 1.27 SD SLC devices upgraded in the field ° Built-in duat Drone gateway%.Each synch i oni7_ation For • Four tine LCD display line digital atarm gateway can have ur) appliances from Penewabie license on communicator/ to U9 wireless devices AMSFCD,Gentex', tin- 40 characters per downloadingsoftware Erne � transrrrrlter(DACT),IP System Sensor',and helps inhibit or optional cellular Wheelock m Available in a red or unauthorized technotogies btackcabinet programming IFP-300 Technical Specifications SPECIFICATIONS ORDERING INFORMATION For a comple e listing of all Physical. IFP-300-Intelligent Fire Alarm Control Panel. coy-pl,ance approvals and certifications,please visit Overall Dimensions:26 4"H x 16 4"W x 4 11"D Red www,farenhyt cora Weight:45 lbs IFP-3008-Intelligent Fire Alarm Control Panel Color:Red or Black Black Microsoft,Windows,and the Windows Logo are Environmental Operating Temperature:32oFto SBUS ACCESSORIES registerec tracemarks 120°F (0oC to 49°C) ortrademarKs of Humidity:0 o 933/0 relative humidity(non- RA-2000,RA-1000,RA-1O00R,RA-100, l,,1lcrosoft Corporation condensing) RA-2O00GRAY-Remote annunciators 6815-Signal Line Circuit(SLC)Expander for All other trademarks IDP/SK devices are the property of their ELECTRICAL: raspectrve owners SD devices IFP-300 Primary AC:120 VAC(cv 60 Hz,3 3A Total -Signal Line Circuit(SLC}Expander for Accessory Load 6A C 24 VDC power-limiter SD devices Tnls document Is not RPS-1000-Power Supply intended to be used for Standby Current:190 mA 5496-NAC Expander installation purposes We Alarm Current:250 mA iry to keep our pl o.fucl Battery Charging Capacity:17 to 55 AH 5824-Serial/Parallel Module information up-to Batter Size: AH max.allowed in control panel 5880-LED 1/0 Module date and accurate We Battery pt 5865-3/-4-LED Annunciator cannot coveralispecific cabinet Larger capacity batteries can be housed in applicatiors or anticipate RBB accessory cabiret 5883-Relay Interface all requirements All spec fications at e subject APPROVALS MISCELLANEOUS ACCESSORIES to mange without notice NFPA 13,NFPA 15,NFPA 16,NFPA 70,&NFPA SKSS-3-Software Suite.Provides ForTechnlcal 72:Central Station,Remote Signalling,Local programming,upload/download and event Support,?lease call Protective Signalling Systems,Auxiliary Protecter reporting 800-446-6444 Premises Unit,&Water Deluge Releasing Service RBB-Remote Battery Box Cabinet.Use for Other Approvals: backup batteries up to 35 AH. UL Listing;CSFM(pending);COA(pending); Dim:16"W x 10"H x 6"D OSHPD(CA)(pending),FM(pending) SK-SCK-Seismic Compliance Kit SK-NIC-Network Interface Card APPROVED RELEASING SOLENOIDS SK-NIC-KIT-Network Interface Card in Cabinet Asco T821OA107 24 VDC 3 A max 0 Hz SK-FML-Multi Mode Fiber Card Asco 821OG2O7 24 VDC 3 A max 0 Hz SK-FSL-Single Mode Fiber Card CELL-MOD-Cellular Communicator in Plastic COMPATIBLE DEVICES Enclosure See the data sheets listed belowfor a complete CELL-CAB-SK-Cellular Communicator in Listing of the IDP,SK,SWIFT or SO devices. Metal Enclosure with lock and key 350361-IDP Device Protocol data sheet 53623 - SK Device Protocol data sheet 350360-SD Device Protocol data sheet 350615&350617-SWIFT devices data sheet For more information wwwfarenhyt com Honeywell 12 Clintonville Road Northfo,cl,CT06L72 800-328-0103 Doc 31,16031 Rev A 1 05i1 r wwwfarenhyt corn 012017 Honeywell Ircernationa,Inc Honeywell Honeywell Farenhyt"Series THE POWER OF CONNECTED Remote Annunciator RA-1000 a gyp,= Yaa^d The RA-1000 is a remote annunciator used to operate and program \ ' IFP-series fire alarm control panels(FACP's).The RA-1000's keypad and l� display match the built-in annunciator of the IFP-1000 control panel .. The remote annunciator connects to the control panel via the RS-485 _ ^ system bus When the system is in normal operation and has AC power, the Power LED is tit and all other LEDs are off The other LEDs turn on as alarms,supervisories,troubles,system silenced and AC power losses occur Installation RA-1000112/RA-1000 The RA-1000 can be surface or flush mounted Use the optional trim ring for surface mounts.When flush mounting an electrical box is optional If using an electrical box,use a 4S,single-gang or double-gang box Agency Listings Compatibility rr� fin City of The RA-1000 is compatible with the following Farenhyt Series FACP's ((((tt 1 V jZ C� APPROVED NY • IFP-2100/IFP-2100ECS • IFP-1000/ECS • IFP-100/ECS • IFP-300/IFP-300ECS • IFP-7S • IFP-50 FEf-JURE S Rj BENEFITS • 80-character backlit • Initiate and end fire • Five Sratus LEDs for; • Support for LCD display(4 lines dtilts with a single key alarms,supervisoty, simultaneous use Of with 20 characters on press trouble silence and AC multiple RA-1000s each line) • View current status by power indications • Wit ing lengths up to • Tactile/audibte alarms,super viscries, • Available in red or gray 6000 ft from the feedback Orttoubles color FACP(depending On • RS-485 SBUS • On-board piezo • UL listed,complies wire gauge and interface to panel sounder audibly with NFPA 72 number of devices on SBUS) • Larger keypad hultOns ndicates alarms, • Accepts user codes or for system reset and troubles'and fire fighter's key si tenc2 supervisorles RA-1000 Technical Specifications IFP-2100 FACP For a cornplete,listing of all compt ance approsals and certifications,please visit www farenhyt corn Microsoft,Windows,and the Windows Logo are ragisterec traeemarks - { ortrademarks of Microsoft Corporation Honeywe,11 is a RA-1000 RA-1000 RA-1000 ragisterec trademarks of and Fa isa l i aadernai k of Honey:)ett Inte�rationat,Inc This cocument is nct intended to be used for installation purposes We ry M seep our product •Up to 31 RA-1000s per system for IFP-2100 or •00-character backlit LCD display Information up-to IFP-2100ECS (4 lines with 20 characters each) date and accurate Vk'e cannut cover all specific •Up to 16 RA-1000s per system for IFP-3001ECS •Wiring lengths up to 6000 ft.from applications or ant,cipate •Up to 12 RA-1000s per system for IFP-1000, the control panel all i equirements All IFP-1000ECS,IFP-100&IFP-100ECS spec4icatlons are suoiect to change4vlthout notice •Up to$RA-1000s per system for IFP-50 or IFP-75 ForTechnica SPECIFICATIONS ORDERING INFORMATION Support,°lease call Dimensions:9 1"W x 74"H x 1 5"D(23 1W x 18 8H RA-1000R:Remote Annunciator Four line LCD 600-446-6444 x 3 8D cm) annuncia*orvnth 2.0 characters per line Rqd RA-1000:Remote Annunciator Four line LCD ENVIRONMENTAL annunciazor with 20 characters per line Gray Operating Temperature.32°F to 120°F (0°C to 4900 OPTIONAL ACCESSORIES Humidity:10%to 93%relative humidity(non- 5860TR;Red frim Ring For surface mounting condensing) 586OTG:Gray Tr m Rlrg Fol surface mounting ELECTRICAL: Operating Voltage:24VDC Standby Current:20mA Alarm Current: 25rnA Wiring Distance: 6,000 ft max from FACP (deperding on wire gauge and number of devices on the SBUS) Max per System:IFP-50 or IFP-75(8),IFP-100/ ECS or IFP-1000/-CS(12),IFP-300/ECS(16), IFP-2100/ECS(31) For more information Leal n more about Honeywell's Fdrenhyt Sol les and other products available byvlsrting vAvwfarenhyt cam> Honeywell Security&Fire 12 Cllntonvdle Road Honeywell Northfo,d CT06L72 Doc 3500111 Rev FI 08/17 TI IC POWER Oi CONNECTED 800-328-0103 €2017 Honeywell Imernationa,Inc Honeywell Farenhyt""Series THE POWER O=CONNECTED Farenhyt IDP-PHOTO-W Series Intelligent Plug-in Photoelectric Smoke Detectors Honeywell's IDP-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics A new modern,sleek, contemporary design and enhanced optical sensing chamber is o ->, = engineered to sense smoke produced by a wide range of combustion . '' sources in accordance with more stringent code standards ;' The IDP-PHOTO-VU Series detector sensitivity can be programmed d in the control panel software Sensitivi:y is continuously monitored and reported to the panel Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for w , " selective maintenance when chamber contamination reaches an unacceptable level IDP-PHOTO-W in 8300-6 base Dual electronic thermistors add 135°F(5700 fixed temperature thermal sensing on the IDP-PHOTO-T The IDP-PHOTO-R is a remote test capable detector for use with DNR Series duct detector housings FEATURES & 9ENEIR TS • New modern profite • Optional remote, • Built-in tamper- • Optional relay for improved singie- gang LED i esistant feature isolatoi,and sounder aesthetics accessory bases • 5eaten against back • Stable communication • Dual LED design pressure • Plugs into separate technique vaith noise orovides 360'viewing • Expanded calor base For ease of immunity angle options instatlation and • Low standby current • Remote test feature maintenance • SEMS screws for from the panel • Two-wire SLC wiring oFtheseparaie connection • Built-in Functional test bdsu switch activated by external rnagnet DETECTOR SPACING AND IDP-PHOTO-R-W:White,low-profile ACCESSORIES APPLICATIONS intelligent photoelectric sensor,remote TR300:White,replacement i lange for Honeywell recommends spacing test capable For use with DNR/DNRW 821OLP and B300-6 bases detectors in compliance with NFPA 72 IDP-PHOTO-R-IV:Ivory,low-profile TR300-IV:Ivory,replacement fLange for In low airflow applications with smooth intelligent photoelectric sensor,remote B21OLP and B300-6 bases ceiling,space detectors 30 feet(9m) For test capable For use with DNR/DNRW RA10OZ:Remote LED annunciator 3 specific information regarding detector INTELLIGENT BASES -32 VDC Mounts to a U S single-gang spacing,placement,and special electrical box For use with B501 and applications referto NFPA 72_ System 8300-6:White,standard flanged B300(A)-6 bases only Smoke Detector Application Guide, low-profile mounting base d0CUmentA05-1003,is available at 8300-6-BP:Bulk pack of B300-6, M02-04-00:Test magnet systemsensor com package contains 10 M02-09-00:Test magnet with B300-6-IV:ivory,standard Hanged telescoping handle INSTALLATION low-profile mounting base CK300:White,detector color kit.Pack of The IDP-PI IOTO-W Series plug-in B501-WHITE:White,standard European 10 detectors use a separate base to simplify flangetess mounting base UL listed CK300-IV:Ivory,detector color kit Pack installation,service,and maintenance 8501-BL:Black,standard European of 10 Installation instructions are shipped with flangetess mounting base UL listed CK300-BL:Black detector color kit each detector B501-IV:Ivory,standar d European Pack of 10 Mount base(all base types)on an flangetess mounting base UL listed electrical backboxwhich is at least 15" B20OS-WH:White,Intelligent, (3 81 cm)deep programmable sounder base. B20OS-IV:Ivoty Intelligent, NOTE: programmable sounder base •Because ofthe inherent supervision B200SR-WH:White,Intelligent sounder provided by the SLC loop,end-of-line basefoitetrofitapplications resistors are not required Wiring"T-taps" B200SR-IV:Ivory,Intelligent sounder or branches are permitted for Style 4 base for retrofit applications (Class"B")wiring 820OS-LF-WH:Write,Low Frequency Intelligent,programmable sounder base When using relay orsounder bases, consult the installation sheet for device B200S-LF-IV:Ivory,Low Frequency limitations between isolator modules Intelligent,programmable sounder base and isolator bases. B200SR-LF:White,Low Frequency Intelligent sounder base for retrofit ORDERING INFORMATION applications NOTE:Detectors must be mounted to one B200SR-LF-IV:Ivory,Low Frequency of the Intelligent Bases listed below Intelligent sounder-base for retrofit IDP-PHOTO-W:White,low-profite applications intelligent photoelectric sensor B224RB-WH:White,plug-in System IDP-PHOTO-IV:Ivory.tow-profile Sensor relay base intelligent photoelectric sensor B224RB-IV:Ivory,plug-in System IDP-PHOTO-T-W:White,same as the Sensor relay base. IDP-PHOTO-W,but includes a built-in B224B1-WH:White,plug-in System 135°F(57°C)fixed-temperature thermal Sensot isolator detector base device B224B1-IV:Ivory,plug-in Systetr Sensor IDP-PHOTO-T-IV:Same as IDP- isolator detector base PHOTO-T but in Ivory Farenhyt !DP-PHOTO-W Series Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height:2.0"(51mm)Installed in B300-6 base The IDP-PHOTO-W series detectors are certifications,please visit Diameter:6 2"(156mm)Installed In B300-6 compatible with the following Farenhyt Series www farenhyt com base 41"(104 mm)Installed in B501 base FACPs: Microsoft,Windows,and the Windows Logo are Weight:34 oz(95 g) D IFP-2100/IFP-2100ECS/RFP-2100 reglsteredtrademarks ortrademarks of ENVIRONMENTAL ® IFP-2000/IFP-2000ECS/RPS-2000 MicrosoftCorporauon Operating Temperature range: a IFP-1000/IFP-1000ECS Honeywell'and System SensorE'are Photo:32°F to 122°F(0°C to 50°C) , IFP-300/IFP-300ECS registered trademark Photo with Thermal:321F to 100°F(0°C to of and Farenhyt"Is a ® IFP-100/IFP-100ECS trademark of Honeywell' 380C) Interratlonal,Inc Thermal Ratings:Fixed Temperature Set point, ® IFP-75 Tnls document Is riot IFP-50 Intended to be used for 135°F(57°C) installation purposes We Sensitivity:UL Applications 0 5%to 4.0%per try to:seep our pi oduct AGENCY LISTINGS AND APPROVALS infoi mation up-tc foot obscuration date and accurate We For exact certification Listings for each model, cannot cover alispecific ELECTRICAL RATINGS please reference the respective agency Web site applications or anvclpate alliequirements All Voltage Range:15 to 32VDC peak UL listed:S6173 specifications ale suoiect Operating Current @ 24VDC:200pA(one FM approved to changewithout nptice ForTecnnlcat communication every 5 seconds with green LED CSFM:7272-0559.0512 Support,Please call blink on communication) 800-446-6444 Maximum Current:4 5mA s 24VDC(one communication every 5 seconds with amber LED solid on) 1 For more information Learn mole about Fcneywell's Farenhyt Series and other prcducts available by visiting www fa rer hyt corn Honeywell Farenhyt 12 Clintonville Road Not thford,CT 06472 Doc 3516291 Rev Al 04/18 Honeywell 800-328-0103 ©2018 Honeywell International Inc HoneywellI Farenhyt", Series THE POWER OF CONNECTED IDP-FIRE-CO-VII and IDP-FIRE-CO-IV Multi-Criteria Fire/CO Detector General Description IDP-FIRE-CO-W and IDP-FIRE-CO-IV ate plug-in addressable devices that provide both fire and carbon monoxide(CO)detection The detector combines four separate '��'°° , sensing elements to sense multiple components of a fire smoke,CO,light/flame,and heat This approach enables enhanced sensitivity to real fire with heightened filrx,,. immunity to nuisance particulates For CO,the detector's electrochemical sensing cell creates a separate signal for life safety CO detection �'r' %A&&� " � ��; Multiple sensors and communication can greatly reduce nuisance alarms compared to single sensing methods Sophisticated algorithms maximize the advantages of all � four sensor types creating our best detection strategy offering heightened immunity to nuisance particulate and enhanced sensitivity to teat fire IDP-FIRE-CO-W in B20OS-WH sounder base • Photoelectric sensors detect airborne particles associated with smoke • Thermal sensors detect heat and rate-of-rise(135°F fixed temperature threshold) Al �. t • Infrared sensors discern light patterns in the environment as an additional data point for alarm determination .� „ ° Ffi 3,.fit;iS This ability to refect certain nuisance alarm triggers such as theater smoke,supports the use of the fire/CO detector in applications where moderate to heavy nuisance conditions exist that might cause single sensing detectors to false alai m. PA10OZRemote LED Annunciator UL models meet UL 268 7th edition and UL 521 listing requirements for fire detection and UL 2075 standard for system-connected life safety carbon monoxide detection Released through the incomplete burning of various fuels.COs a colorless,odorless ,,, and deadly gas that is virtually impossible to detect with the human senses Because CK300-IR-8L TR300 the potential exists for dangerous levels of CO to accumulate in almost any building, Color Kit Trim Ring legislation mandating the use of CO detection in commercial spaces continues to g row B200S series intelligent sounder bases are recommended for use with IDP-FIRE-CO-W and IDP-FIRE-CO-IV.These bases can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication The B200S settes bases recognize the System Sensor synchronization protocol for use as a component of the general evacuation signal—along with other System Sensor Audible/Visible devices—when connected to a power supply or Fire Alarm Control Panel(FACP)output capable of generating the Systern Sensor synchronization pulses FEATURES & BENEFITS • Detects all four major • Separate audible signal • Automatic drift • New modern profile • UL 268 7th edition,UL elements of a fire for fire or CO alarm compensation for with expanded color 521,and UL 2075 when used with a smoke and CO sensors options listed • Separate CO detection B200S series base signal • ReaiTest"CO testing • Uses only one address • 10-year CO cell with • Highest nuisance capability on the SLC loop end-of-fife warning alarm immunity IDP-FIRE-CO-W and IDP-FIRE-CO-IV Technical Specifications PHYSICAL/OPERATING ORDERING INFORMATION FarenhytO and RealTest"are Dimensions: IDP-FIRE-CO-W.Advanced multi-criteria fire/CO registered trademarks of detector,bright white color Honeywell International Inc Height 2 7'(69 mm)Installed In B200S series sounder 9 (02019 All rights reserved base IDP-FIRE-CO-IV Advanced multi-criteria fire/CO Unauthorized use of this Diameter 6 875'(175 mm)installed In B200S series detector,Ivory color document is strictly sounder base Bases prohibited Weight 3 4 oz.(95 g) B501-WHITE 4"Mounting base,white This document is not intended Operating Humidity Range:15%to 90%Relative B501-WHITE-BP 4°mounting base,white,10-pack to be used for installation Humidity,Non-condensing 8501-IV 4"Mounting base,Ivory purposes We try to keep our product Operating Temperature Range:32°F to 100°F(0°C to B501-BL 4"Mounting base,black date and acocrurate mation Weccannot 38°C) B300-6 6"Flanged mounting base,white cover all specific applications Air Velocity:0 to 4000 ft/min (0 W 1219 2 m/min) B300-6-BP.6°Flanged mounting base,white,10-pack or anticipate all requirements All specifications are subjectto ELECTRICAL SPECIFICATIONS 8300-6-IV 6"Flanged mounting base,Ivory change without notice Operating Voltage Range:15 to 32 VDC B20OS-WH Intelligent addressable sounder base,white Operating Current @ 24 VDC:200 uA(one B20OS-IV Intelligent addressable sounder base,ivory Country of origin Mexico communication every 5 seconds with green LED blink on 8200S-LF-WH Intelligent addressable sounder base, communication) low-frequency,white Maximum Alarm Current:2 mA @ 24 VDC(one 820OS-LF-IV Intelligent addressable sounder base,low- communication every 5 seconds with red LED solid on) frequency,ivory Maximum Current:4 5 mA @ 24 VDC(one B224BI-WH Isolator base,white communication every 5 seconds with amber LED solid B224BI-IV.Isolator base,Ivory on) B224RB-WH Relay base,white Isolator Load Rating:0 0063 8224RB-IV Relay base,ivory CO MONITORING UL STANDARD REFERENCE Accessories Alarm thresholds(in parts per million)are as follows for SMB600 Surface mounting kit(flanged) 70±5ppm Detector response time 60—240 min TR300 Trim ring,white 150±5ppm Detector response time 10—50 min TR300-IV Trim ring,Ivory 400±10ppm Detector response time 4-15 min CK300-IR IR color kit(includes cover and trim ring),white, STANDARDS 10 pack Per UL standard 2075,the IDP-FIRE-CO-W and IDP- CK300-IR-IV IR color kit(includes cover and trim ring), FIRE-CO-IV have been tested to the sensitivity limits ivory,10 pack defined in UL Standard 2034 CK300-IR-BL IR color kit(includes cover and trim ring), UL Standard UL 268 7th Edition black,10 pack RA100Z.Remote LED annunciator AGENCY LISTINGS AND APPROVALS M02-04-00 Detector test magnet The listings and approvals below apply to the IDP-FIRE- M02-09-00 Telescoping test magnet CO-W and IDP-FIRE-CO-IV In some cases,certain modules may not be listed by certain approval agencies, or listing may be In process Consult the factory for the latest listing status UL 56173 CSFM 7272-05590517 Honeywell Fire Solutions 12 Clintonville Road Northford,CT 06472-1610 203 484 7161 FH-620021 A 105/19 ILN ©2019 Honeywell International Inc Honeywell Honeywell Farenhyt'"'Series THE POWER OF CONNECTED Addressable Single Action and Dual Action Pull Stations , IDP-Pull-SA & OP-Pull-DA " The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station The IDP-Pull-DA is a dual action pull station requiring two motions to active the station Both pull stations at e designed to l Nanas�t3 work with Honeywell Farenhyt series fire alarm control panels(FACPs) R IDP—PULL-5A Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-1/0 surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2 13"(5 40 cm)or double gang or 4"(10.61 crn) square electrical box You can also use the optional(System Sensors' o� PN BG-TR)trim ring if the station is being semi-flush mounted Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible with 1hefollowing Farenhyt Series FACPs • IFP-2100/IFP-2100ECS/RFP-2100 IDP-PULL-DA • IFP-2000/IFP-2000ECS/RPS-2000 • IFP-1000/IFP-1000ECS • IFP-300/IFP-300ECS • IFP-100/IFP-100ECS • IFP-75 • IFP-50 FEATURES & BENEF1 T S • Installer can open • Key operated test and • Meets the Americans • Reliable analog ° Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuatot Accessibility trouble-free operation word Activated condition Guidelines(ADAAG) appeals,clearly • Key matches Braille Text on station • Dual-color LED is compatible FACP controls and operating handle indicating the station visible through handle locks mechan€sins has been pulled guidelines(Section • Rotaryaddress of station blinks green • Meeis ADA 4,1.313]) switches for fast UL Listed,,St including to indicate norma! UL�8.Standard of operation and remains maximum requirement for 5 tbs pull force to ° Shell,door.and handle installation PAanu<alty Actuated steady red in an alarm active molded from durable Signaling System condition LEXAN` • CSFM Listed • MEA Listed IDP-Pull-SA and IDP-PUII-DA Technical Specifications urrN For a complete listing of all rW cornpliance approvals and certifications,please visit www farenhyt corn Ct ,A --•---- ---- ---.--^--- — -- N9rcrosoft,Windows,and the Windows Logo are a. clause I registered trademarks ortracfemarks of camwan>e eACP `r>`a € fa$ e''5 Microsoft Corporacion X11 _�•g a • „`; Honeywe,11 and Syste^i Sensor'are 44 ragistereotrader,,arks ° M1:' s of and Farenh * is a trademaikofHoneywell �` Interratrenal,Inc Whin10P.Pu11SAS 10P.Pu11 DA Pull aut.­ Tnls document Is not Intended to be ubed for SPECIFICATIONS" ORDERING INFORMATION try:o kkeep instaleep purposes We aur product Physical:5 51-1 x4"D(14cm x 10 2cm) IDP-Pull-SA:Single Action Pull Station info,mation up-to Shipping Weight:5 LI oz IDP-Putl-DA:Dual action Pull Station date and accurate We cannot rover all specific Housing Material:LEXAN polycarbonate resin applications cr ant cipate Bi-Colored LED: ACCESSORIES all requirements All Blinking Green:Normal BG-TR:Optiorattrim ring spec'fications aresuoiect Steady-Red:Alarm SB-1/0:Surface backbox,indoor/outdoor to change without notice Switch:Single pole,single throw(SPST)normally *Unless otherwise noted,specifications apply to ForTechnicai open(N/O)switch which closes upon ac:-vation of IDP-Pull-SA and IDP-Pull-DA Support,Please call the pull station 800-446-6444 ELECTRICAL RATINGS Operating Voltage:15—32VDC SLC Standby and Alarm Current:350µA Wire Gauge:Up to 12AVVG(3 1 nim2) ENVIRONMENTAL Operating Temperature:321-120'F'OIC—4910 Humidity:10 to 930/6 non-condensing) For more information Learn niore about Honeywell's FarenhytSenes and other products available byvisiting wwwfarerhyt corn Honeywell Security&Fire 12 Clintonville Road Honeywell Not tnford,CT 06L i?_ Doc',3102F61 Rev 109/17 THE POWER OF CONNECTED 800-328-0103 02017 HoneywclUrternatiena Inc .i j Honeywell Farenhyt" Series r6 THE POWER OF CONNECTED Intelligent ®n® lay Duct Detector DNR /DNRW ti The DNR Intelligent non-relay photoelectric duct smoke detector '} housing and DNRWwatertight non-relay photoelectric duct smoke detector housing(head not included)are for use with Silent Knight IFP-series fire alarm control panels(FACPs) DNR The DNR and DNRW feature a pivoting housing that is flexible enough to fit configurations frond square to rectangular They Feature low- flow technology that enables duct smoke detection throughout a broad range of airflow environments Many difficult to solve HVAC Compatibility apptications occur in low airflow duct applications where reliable The DNR and DNRW are compatible smoke detection is critical These duct detectors can detect smoke with the following FACPs at air speed velocities of 100 feet per minute or greater,white continuing the same reliable pei foi mance to 4000 feet per minute. ° IFP-21.00/ECS/RFP-2100 ® IFP-2000/ECS/RPS-2000 By sampling air currents passing through a duct and giving dependable performance for shutdown of fans,Mowers,and air . IFP-1000/ECS conditioning systems,the DNR and DNRWprevent the spread • IFP-300/ECS of toxic smoke and fire gases through the protected area . IFP-100/ECS The intelligent duct detectors communicate and are continuously ® IFP-75 monitored through the FACP signaling line circuit(SLC)loop Detector . IFP-50 sensitivity changes caused by dirt,temperature,or humidity are repotted to the FACP,attowmg compensation algorithms to maintain the detector's • IFP-25 set sensitivity.An advanced indication at the panel identifies the detector address,allowing foi selected maintenance to be performed as needed installation The DNR and DNRW are designed for use in air handling systems that have air velocities or 100 to 4000 feet per minute(0 5—20 3 m/s) FEATURES & BENEFIT S e Photoelectric, n Patented sampling a Pravides trouble m Transparent cover for MEAL€steel- integrated tow-flow supe instals from sign it in the evert the convenient visual 225-02-E Vol V technology `rant or back of the ser;sor cover is inspection (IDP-Photo or detector with no tools i emoved of impropet ly ® Ut_268A listed IDP-PhotoR detector required inseat'.ed head sold separately) - Remotete5ting m Available space within F I;asity accessible code capability ® Air velocity rating from housing to wheels on sensor head 100 to 4000 feet per accommodate (IUP-Photo sold ® DNRW is fisted as a mina!c(0.5 to 20.32 mountiny of relay soparatety) watertight enclosure meters per second) nodute d UL re'ognizea field aJowing for use in the most extreme • Support for Class 8 or Easy to clean replaceabte vower and environments Class A Wiring sensor boards CSFM l issed DNR Technical Specifications WIRING FOR INTELLIGENT NON-RELAY DUCT SMOKE DETECTOR For a complete listing of all DNR to RTS451/RTS451KEY/RTS151/ DNR to RTS451/RTS451KEY DTS151/ compliance approvals and cerUficatiens,please visit RTS151KEY with"R"Remote test capable RTS151KEYwith DCOIL option(Non remote test www.farenhyt com detector head option: capable Microsoft,Windows,and the Windows Logo are registered trademarks TEST COIL+ ortrademarksof TESTCOIL+ k s TEST COIL- ra>= Microsoft Corporation RTsisvRTS451KEY TESTCO[L- sung ® RT51S1AIT5151KEY COMM+ ® 1 Honeywell',is a COMM+ registerec trade rark T OUT(CONVONLY)+ P RTS4sitRTsd;1KEY ofar,dFarenhytTMisa OUT(CONVONLY)+ _____ J; COMM- ® RTS151rRTSi51KEY tradernarkofHoneywell COMM- ® RA/R75- REMUTETESTSTADON International,Inc 3 :JUMPER RA/RTS- RA+ iIPERUNIITI This cocumentisnot RA+ Ql aintended to be used for __1 RTS+ Q instatlazion purooses We RTS+ F PER UNIT iLSFCUiLOPIKN try to keep our product 95mA CURRENT DRAW mformaUon up-to date and accurate We "IMPORTANT NOTES: cannot cover all specific SPECIFICATIONS applications cr anticipate (for non remote test capable housing) alliequuernents All Physical: •The use of either RTS151 or RTS151KEY requires speafications are suoiect (Rectangutar):14 38'(37 cm)L x 5"(12 7 cm)W x the installation of an accessory coil,DCOIL,sold to change without notice 2 5"(6 6 cm)D separately Please referto the DNR or DNRW (Square):775°(19 7cm)L x 9'(22 9cm)W x 2 5° ;nstattation manual for mere.nformabon For Technical Support,Please call (6 35cm)D •The RTS151/RTS151,CEY test cei.circuit requ,res 800-446-6444 Weight:16 lb anexternat 24VDC power supply which irusz be LIL listed ENVIRONMENTAL ACCESSORIES Operating Temperature:-41Fto-158°F(-2011C to DSTl:Metal Sampling Tube Duct Width up to 1' 70°C) DSTl-5:Metal Sampling Tube Duct Widths 1'-2' Humidity:0 to 95%non-condensing) DST3:Metal Sampling Tube Duct Widths 2'-4' AIR VELOCITY DST5:Metal Samptrrg Tube Duct Widths 4'-8' 100 to 4000 ft/min(0.5-20.3 m/s) DST10:Metal Sampling Tube Duct Widths 8'-12' DH4000E-1:Weatherproof Enclosure ELECTRICAL EXT:Metal Exhaust l Li be Duct width 1' Please see detector head installation manual for RA10OZ:Remote LED Annunciator electrical specifications DCOIL:Duct Accesscry Coil (see important note for detail, ORDERING INFORMATION RTS151:Magnetic Remote Test station DNR:Intelligent non-relay duct smoke detector RTS151KEY:Key-Activated Remote Test station DNRW:Watertight non-relay duct smoke detector M02-04-00:Test Magnet IDP-PhotoR:Addressable Photoelectric Detector P48-21-00:Replacemen End Cap for Metal with remote test capability(not included with DNR) Sampling Tube IDP-Relay:Addressable Relay Module,must be added if relay function is required,(fits in housing) For more information Leain more-,I bout Honeywell's Fa renhyt Series and other products available by visiting www farenhyt com Honeywell Security&Fire 12 Clintonville Road Honeywell Noithford,CT061-72 Doc 3500851 Rev H 1 08/17 THE POWER OF CONNECTED 800-328-0103 V 2017 Honeywell.Irternationat Inc Honeywell Farenhyt` Series THE POWER OF CONNECTED Addressable Monitor Module ��«� ���.... ���� OP-Monitor The IDP-Monitor is an addressable monitor module for use with the Honeywell Farenhyt Serres fire alarm control panels (FACPs) The IDP-Monitot acts as an interface to contact � ' u devices,such as waterflow switches and putt stations The IDP-Monitor supports Class A supervised or Class B supervised wiring to the load device Conventional 4-wire smoke IDP-MONITOR detectors can be monitored for alarm and trouble conditions Compatibility Installation The IDP-Monitor is compatible with the The IDP-Monitor mounts directly into a 4"square electrical box The following Farenhyt Series FACPs box must have a mini rium depth of 2-1/8".A si.irface mount electrical • IFP-2100/IFP-2100ECS/RFP-2100 box(System Sensor'PN SME500)is available from Honeywell • IFP-2000/IFP-2000ECS/RPS-2000 • I FP-1000/I FP-1000ECS • IFP-300/IFP-300ECS • IFP-100/IFP-100ECS • I FP-75 • IFP-50 FEATURES & � E !` E 1 ' S • Isolates short circuits • Standard 4 inch on an SLC loop electrical box • Protects the modules mounting on the SLC loop so • SOAS screws for easy other devices continue wiring to operate • UL Listed • Panel controlled • CSFM Lister! status LED that flashes green in • MEA Listen 427-91-E normal state and is VOL X solid red in alarm IDP-Monitor Technical Specifications TO "'� ;, _ `'� F„ yJ,ELC:H For a complete listing of all �Rc^fDJUOEYpE con;pl ante approvals and NGVT F unh�Nr,�t<wL,stEO�I,T.<T ++ri�•.f certifications,please visit CL(._4.TAL DE4 aY�A'n•3EU5£C DO111 C<Nhfrt N•" .. S TCIISTWi'O1W gF www farenhyt cam F4c•_nFiiAMATIN6 St.PERY"" On 0 u Q ..^.�k"S/X PAYE.S CV I .FwRtY:+EYn'E9Ot.Ttt:0.A+F N:O,iF � Microsoft,Windows,and the Windows Logo are �s reglsterea tracemarks E R3•K Q a ortrademarks of vtvnrs»�J:aatry ls:,nx r.�:,c�r;orar.<_,.ar.o Microsoft Corpora-,ion url'M1T N3 CfuhfGN�!','%:1 hfP/.4"M1.F3 vAiq,t tCNigtl C-E DEv 2J PCR H on eywe tl0 and aH•sACru:Errs•rs-zLatr,:n m4taxn�Nc System SensorE'are Typical Wiring for IDP-Monior Module,NFPA Style B reglsterec tracernarks TO vx- FRWf frWE_C.R of and Fa renhyt-Is a c�"<= C> o PK_�"IUSWIIC- trademark of Honeywell MONIO Inte,rattonaL,Inc ANY NJRiSFR�I__�SFOCOh" MO�'.ftF I.SLC Wh0T'�D( C;N\_CTAtU,A._EU C LSTEOCPM+'A'ISLE INE-JAM INTVTf Ju,SJPEFYI�RV,rR /� Q a �Qh C.C)NTik,^ 'S^full Tris document Is not 6E0.4 TY LEV CES Cit TE SATE MODE v LI Intended to be used for Installation purposes We ,.� try to seep our product Eo:>vc.,c,la Information up-to ihT�eW¢,ta Q I "AR NZ SHMT..S SJ.'E�'A SE AND MNkUMt ED' date and accurate We TfFtS NA SSL'i cannot cove,all specific 44sS CO T_T CLlF nE ME zs PE's applications cr ant apate %W4GCAMT PRS f1'r AT ON U.ST,L'T�NS aLhe_qullements All Typical Wiring for IDP-Monior Module,NFPA Style D specifications are suoiect to change without noose SPECIFICATIONS* ORDERING INFORMATION ForTechnlcal Physical:4.5'H x 4"VJ x 1.25 D(114 x 10 2 x 3cm) IDP-Monitor:Monitoring ModuleSuppol t,?tease call800-446-6444 Shipping Weight:6 3oz(196g) ACCESSORIES ELECTRICAL RATINGS SM8500:4"Squa,e Surface Mount Electrical Box Operating Voltage:15-32VDC SLC Standby &Alarm Current:350µA End of Line Resistance:47k52 Max.IDC wiring resistance:_,50052 Max.IDC Voltage'11V Max.IDC Current:450µA SLC Loop Resistance:405)max ENVIRONMENTAL Operating Temperature:32°-1201F(00C-49°C; Humidity:10 to 93%non-condensing) For more information Learn more about hcneywetl's Fa renhyt Seri es and other products available byvislting wwwfarenhyt com Honeywell Security&Fire 12 Clintonville Road Honeywell Northfo,d,CT C6L,72 Dac,3502881 Rev IQ 08;1' THE POWER OF CONNECTED 800-328-0103 Ar:2017 Honey'r eIt Irite rnabonat Inc. Honeywell THE POWER OF CONNECTED I Farenhyt"Series Addressable Relay Module IDP-Relay "R The IDP-Relay is an addressable relay module for use with the Honeywell Farenhyt Senes fire alarm control panels(FACPs) '¢ The IDP-Relay allows a Farehyt FACP to switch discrete contacts by code command.The relay contains two isolated sets of Form C contacts,which operate as a DPDT switch No ''_k ; supervision is provided for the notification appliance circuit IDP-RELAY The IDP-Relay contacts can be used for virtually any normally open or normally closed application Each IUP-Relay is programmed with a Compatibility unique signaling line circuit(SLC)loop address.When an event occurs The IDP-Relay is compatible with the that controls the IDP-Relay,the relay is triggered bythe FACP following Farenhyt Series FACPs • IFP-2100/IFP-2100ECS/RI-P-2100 Installation • IFP-2000/IFP-2000ECS/RPS-2000 The IDP-Relay mounts directly into a 4'square electrical box.The box ° IFP-1000/IFP-1000ECS must have a minimum depth of 2-1/8".A surface mount electrical • IFP-300/IFP-300ECS box(System Sensor6 PN SM13500)is available from Honeywell • IFP-100/IFP-100ECS • IFP-75 • IFP-50 FEATURES P4 BENEF —' S • Two sets of Form C • Relay programming is • SEWS screws for easy contacts completely flexible— wiring • Contacts are rated for can be mapped to • UL Listed a variety of amps(see zone conditions CSI=Fr1,_isPed Specifications) • Potting LED visible • Panel controlled through the cover • MEA Listed 386-02-E status LED that plate Vol 11 flashes green in • Attractive ivory cover normal state and is plate solid red in alarm • Rotaryaddress switches for fast installation IDP-Relay Technical Specifications I CONNECT MODULES TOCISTEDCOldPATIBLE i For a complete fisting of at[ CONTROL PANELS ON�_Y {- FROM PANEL TO DEVICE OR PREVIOUS compl"once approvals and DEVICE f-) 00 DEVICE certifications,please visit RELAY CONTROL www fa ren hyt Lo rYi MODULE If any wing to Terminals 4-90 is Nonpiverirm.ledThe CB500bamer Microsoft,Windows,and ��O O is required The CB500 includes a the Windows Logo are o e Nonpower hm,tedlabel.which lske ectracemarks must be placed over the Power re g Tn @ Lumtedterrmnaiinformation on ortrademarksof Relay Common 2 Tv r the name plate label Microsoft Corporation Normally Closed Ts Tz ;+> HoneyweUl"arid Normally Open 2 re ra Systems,Sensor'ate Relay Common 1 n r Unused registerec trademarks Normally Closed 1 rs ;�' rs Normally Open 1 of are,Farenhyt`is a ❑O'@° s ops O 'NOTE ANY FAULT IN THE POWER SUPPLY IS LIMITED trademark of Honeywell TOTHAT Z04E AND DOES NOT RESULT IN A FAULT IN Intematicnal,Inc Low " ASEPARATE ZONE. Trus document Is riot Typical Wiring for IDP-Relay Module Intended to be ubed for Installailon purposes We try to<eep our product Info•mation up-to SPECIFICATIONS* ORDERING INFORMATION date and accurate V cannot cover at',specific Physical:4 275'H x 4"675 W x 1 L D IDP-Relay:Relay Module applications or anticipate Shipping Weight:6 3oz(1968) all Iequiiemerits.All ACCESSORIES specifications ale suoiect ELECTRICAL RATINGS SMB500:4"Square Surface Mount Electrical Box to change without noimce Operating Voltage:15 to 32VDC CB500:Vodule Barrier Used to separate power ForTechnicai Standby Current:300f1A max @ 24VDC(one limited and non-power limited wit Ing In a)unction Support,?lease call communication every 5 sec with LED enabled) box 8CO-446-6444. LED Current:5 5 mA(with LED latched on) Relay Contact Ratings: 2 OA @ 25VAC(PF=35),non-cooed 3 OA @ 3OVDC resistive,non-coded 2 OA @ 3OVDC resistive,codeo 0 46A @ 30VDC(L/R=20ms),non-coded 0 7A ra,70 7VAC(PF=35),non-coded 0 9A t�j 125VDC resistive,non-coded 0 5A p 125VAC(PF=75),non-coded 0 3A: 125VAC(PF=35),non-coded ENVIRONMENTAL Operating Temperature:32°-120cF(0°C—49°C) Humidity:10 to 93%non-condensing) For more information Learn more about t-cneyv/ell's Farenhyt Series and other products available byvisrtlrg wwwfarenhyt corn Honeywell Security&Fire 12 Clintonville Road Honeywell Not thford,CT 06/172 Doc 9902901 Rev K 109/17 THE POWER OF CONNECTED 800-328-0103 U 20t 7 Honeywell In;ernationat Inc a . SYSTEM SENSOR Indoor Selectable- ��s"a{ O utput Strobes d Horn Strobes for � � � ���� � � 'N6 Ceiling Applications , wtrtI L System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower " r re current draw and modern aesthetics. s Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal Intrusion Into the back box easy-to-use line of horns,strobes,and horn strobes in the Industry with lower current draws and modern aesthetics With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Seises can meet virtually any application requirement at 15 and 30 candela • Field-selectable candela settings on ceiling units The entire L-Serres product line of ceiling-rnount strobes and horn 15 30,75,95, 115, 150,and 177 strobes include a variety of features that Increase their application versatility while simplifying installation All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so Installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAleit and SpectrAlert boxes With an onboard shorting spring,installeis can test wiling Advance devices continuity before the device is installed • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections Agency Listings SIGNALING L F M M�j LISTED APPROVED U� S5512 FM pp­ed e-ept 7125-1653 0504 S4011 fcr ALERT meaeis 7135-1653 C503 3057333 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1V2-inch back box,4-inch octagon back box,or double- gang back box Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box A universal mounting plate shall be used foi mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate Also,L-Series products,when used with the Sync®Circwt"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8 5 and 17.5 volts,24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150.and 177 Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances flashing at 1 Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on hoi n strobe models shall operate on a coded or non-coded power supply Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service The module shall synchronize L-Serres strobes at 1 Hz and horns at temporal three Also while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit The module shall synchronize multiple zones Daisy chaining two or more synchronization modules together will synchronize all the zones they control The module shall not operate on a coded power supply Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second [Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17 5V(12 V nominal)or 16 5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6 8"diameter x 2 5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6 9"diameter x 3 4'high(175 mm ciameter x 86 mm high) (SBBCRL,SBBCWL) Notes- 1 Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2 P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd AVDS88800 UL Current ®raw Data 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 ® es- 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3 1K Temporal High 111 164 69 94 147 163 184 229 257 3 1 K Temporal Low 103 163 54 88 143 155 185 212 252 3 1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3 1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3 1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3 1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Volts Volts Switch Position Sound Pattern d8 DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3 1 KHz Temporal High 83 88 88 6 3 1 KHz Temporal Low 76 82 82 7 3 1 KHz Non-Temporal High 84 89 89 8 3 1 KHz Non-Temporal Low 77 83 83 AVI)S60800 L-Series Dimensions 247 06,83 1 37 0692 250 0 CDo 0 C 00 0 ra — CD Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 0 a Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRIL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Sl Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White 02017 system Sensor SYS TEM 3125 Ohio Avenue a St Charles,IL 60174 l specification.sl to G large vAthout not ce Visit systemsensorcon, 'a we,tirml nto,­t.r,i,z1jdaig he1.t­t�ea,.nftnsd,a­heat Phone 800-SENSOR2 Fax.630-377-6495 NVD586801-03/17 E Al .So R. SMSTEM SEMSOR" Outdoor Selectable- Output Horns, Strobes,, an Horn Strobes for Wall Application SPECT rt SpectrAleri0 Advance outdoor audible visible products are rich with features that cut installation times and a maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from-40°F to 1 51°F • Field-selectable candela settings.15, 15/75,30,75,95.110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation a(15 and that increase application flexibility and simplify installation First, 15,175 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements • Rated from-40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications This mounting,plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-ln design with minimal intrusion into the back box devices are installed,so installers can vet ify propel wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to§altwater SIGNALING .0 corrosion Knock-outs located on the back eliminate the need to drill holes for screw-in mounting Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch TED FM MEA 7300-'a,3 87(outdoor stro0as) LIS 54611'chi LIS hm strobes horns) APPROVED chime strobes) approved 71'-5-'053 188(her-,SPcbas, knock-outs at the back A screw-in NPT plug with an O-ring gasket S3593(cutocor and alert Strobes) 3023573 MEA452-05-E 7135-'653'Edthorns chimes) for a watertight seal is included with each back box SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications - a General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box A universal mounting plate shall be used for mounting ceiling and wall products The notification appliance circuit wiring shall terminate at the universal mounting plate Also,SpectrAlert Advance products,when used with the Sync•Circut"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts When used with the Sync•Circut Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts,24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95,110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL The strobe shall be suitable for use in wet environments Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lensheflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern These options shall be set by a multiple position switch On four-wire products,the strobe shall be powered independently of the sounder The horn or horn strobe models shall operate on a coded or non-coded power supply The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments UNARM Operating Temperature -40°F to 151`F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangez 8 to 17 5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mourit Dimensions(including lens) 5 6"L x 4,7-W x 2 5-D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5 6""L x 4,7-W x 1.3'D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5 7"L x 5 1-W x 2 0"'D(145 mm L x 130 mm W x 51 mm D) Notes: 1 Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd, AVDS01201 UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-175 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Ternporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15[75 15 15f75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input _•i35 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Tempoial Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatues,listed . e a candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table Volts Volts Reverberant Anechoic i , y�,; Switch Sound MMEW Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 Temporal 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7, Coded High 82 82 88 88 93 92 101 101 177 177 8r Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDSO 1201 SpectrAlert Advance Diagrams �a- 4.7" 2.5" m�rAn 5.6" O 0 Wall-Mount Horn Strobes ® ® Wall Plastic Weatherproof Back Box 0 LIP Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*7 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weather proof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK-t 2-Wire Horn Strobe,High cd White,Outdoor(includes plastic weatherproof back box) P4RK` 4-Wire Horn Strobe,Standard ed Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd Red,Outdoor,120 V(includes plastic weatherproof back box) Wail Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK`t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK" Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marling on cover),e g,P2RK-P t Add"-R"to model number for weatherproof replacement oevice(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW "Standard cd"refers to strobes that include 15,15[75,30,75,95,110,and 115 candela settings "High cd"refers to strobes that include 135,150,177,and 185 candela settings When replacing standard outdoor units both the device and back box must be replaced. fSYSTEM 02012 System Sensor 3825 Ohio Avenue•St Charles,IL 60174 Product specnccauons sub;ect to charge waha.t notce Visd systemsensor con, Phone 800-SENSOR2 o Fax 630-377-6495 'a cu-reit prodW,nfo,mat or,ircldding ha latestverston cftvs data sheet kVDS012C i•3112 Best Quality Fire Protection Corp. 3905 Ole Jule Lane Mattituck, NY 11952 Phone 631-,298-3894 December 18, 2020 DEC 1 8 2020 Jim Southold Town Fire Marshal Enclosed please find all four- stamped prints as,well as head cuts for the Mattituck Shopping Center/Stonybrook Medical Center job. Please review and let me know when approved. Please feel free to contact me with any questions or concerns @63 If there are any fees please contact me at this number as well. Willia6 Gremler Jr. BQFP License 9 2941-MP FireLockTm V38, K5.6 ✓atau110r Models V3801, V3802 40.50 V3801 and V3802 1.0 PRODUCT DESCRIPTION Models:V3801 and.V3802 Style:Adjustable Concealed, Ordinary Hazard and Light Hazard K Factor:5.6 Imp./8.1 S.1.1 Nominal Thread Sizw.W NPT/15 mm BSPT Max.Working Pressure: 175 psi/1207 kPa/12 bar Factory Hydrostatic Test- 100% @ 500 psi/3447 kPa/34 bar Min.Operating Pressure:7 psi/48 kPa/0.5 bar Temperature Rating:See chart in section 2.0 1 For K-Factor when pressure is measured in bar,multiply S.1.units by 10.0. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 40.50 2558 Rev P Updated 01/2019 0 2019 Victauiic Company.All rights reserved. 1 v, victaulic.com 2.0 CERTIFICATION/LISTINGS C&S 0 (LISTED 3E LPCB Approvals/Listings Approvals/Listings Model V3801 V3802 Orifice Size(mm) 13 13 Nominal K Factor Metric SI? 8.1 8.1 DeflectorType Concealed Pendent Concealed Pendent Approved Temperature Ratings F°/c° 135°F/570135°F/57°C PcULus 155°F/68°C 155°F%68°C 175"F/79°C175°F/79°C.,; 200°F/93°C 200°F/93°C 155°F/68°C FM3 NONE 175°F/79°C 200°F/93°C ' 135°F/57°C 135°F/57°C NY, #62-99 E` 155°F/68 C -155°F%68"C- UMEA3 �. 175°F/79°C ` 175°F/79°C" 200°F/93°C 20D°F/93°C , 135°F/57°C 135°F/57°C C155°F/68°C 155°F/68°C SFM3#7690-0531:112 175°F/79°C 175°F/79°C 200°F/93C 200°F/93C `155°F/68°C Sprinkler/138°F/59°C Cover 155"F/68'C Sprinkler/138°F/59°C Cover - LPCB y -175°F/79°CSprinkler/165°F/74°C Cover'- "175"F/79.*C�Sprinkler/165"F/74"CC9vey " 200'F/93°C Sprinkler/1659F/74°C Cover `200°F/93'C Sprinkler/165°F/74"C Cover 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C VNIIPO 175°F/79°C 175°17//9°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C ZSTDY "K ZSTDY, CCC, 155°F/68°C' 155°F/68°C. ' 200°17/93"C 2 For K-Factor when pressure is measured in bar,multiply S.I.units by 10 0 3 Recognized by FM as standard response only. NOTE • Listings and approvals as of printing.All are approved open. 40.50 2558 Rev P Updated 01/2019 ®2019 Victaulic Company.All rights reserved. victaulic.com 2 ✓atauhar victaulic.com 3.0 SPECIFICATIONS—MATERIAL Deflector: Bronze Cover Plate: Fusible solder Bulb: Glass with glycerin solution Bulb Nominal Diameter: ❑ Standard:5,0 mm ❑ Quick Response:3,0 mm Load Screw: Bronze Pip Cap: Bronze Spring: Beryllium Nickel Seal: Teflon4 tape Frame: Brass Pins: Stainless steel Cup: Cold rolled steel,zinc chrome plated Cover/Escutcheon: Brass Lodgement Spring: Stainless steel Protective Cap: Polyethylene Installation Wrench: ❑ Concealed:V38-4 or V38-5 Sprinlder Finishes: m ❑ Plain Brass(only) Cover Finishes: ❑ Chrome Plated 0 ❑ White painted5 ❑ Flat Black Painted5 O ❑ Custom Painted5 4 Teflon is a registered trademark of Dupont Co. 5 UL Listed for corrosion resistance. • 40.50 2558 Rev P Updated 01/2019 ©2019 Victaulic Company.All rights reserved. victaulic.com 3 ✓otaulie victaulic.com 4.0 DIMENSIONS 2TI/i?/68 mm Max Hole 23/s'/60 mm Min Hole 11 11 ii ii 25/,6"/59 mm 1 W138 mm Typical Ceiling Tile f MINIMUM EXTENSION Finished Surface (drawings not to scale) 33/,6"/80 mm 213/mY71 mm 2751 mm W113 mm Adjustment Typical Ceiling Tile 3 AVE'mmRn,shed Surface Cove:Plate MAXIMUM EXTENSION (drawings not to scale) 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets,or any local standards. 6.0 NOTIFICATIONS AWARNING a Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers, before proceeding with installation of any sprinklers. - Always wear safety glasses and foot protection. a Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. 0 Installation rules,especially those governing obstruction,must be strictly followed. e Painting,plating,or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems.In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters:P.O.Box 31,Easton,Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. 40.50 2558 Rev P Updated 01/2019 0 2019 Victaulic Company.All rights reserved. victaulic.com 4 ictaullicr victaulic.com 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from—670F(-55°C) up to those shown in table below. Sprinkler Sprinkler—V3801,V3802 Cover—V38 Temperature—°F/°C Temperature—*FPC Maximum Maximum Nominal Ambient Nominal Ambient Temperature Victaulic Part Temperature Temperature Glass Bulb Victaulic Part Temperature Temperature Classfication Identification Rating Allowed Color Identification Rating Allowed Ordinary A 135°F/57°C ,t,' 100°F/38°C`.y'_ Orange A6 135°F/57°C,, u100°F/38°C",, Ordinary C 155°F/680C 100°F/389C Red D7 1650F/74°C 150°F/65°C Intermediate E, 1'75°F/79°C 4 150°F/65°C ` Yellow, Intermediate F 2000F/930C 150°F/65°C Green High" 1' 286°F/141°C' 225°F/107YC Blue' Extra High" K 360TA820C 300°F/149°C Purple M Operi` — " No Bulb 6 A For use with Standard or Quick Response Concealed Sprinkler 135°F/57°C or 155°F/68°C 7 D For use with Standard or Quick Response Concealed Sprinkler 175°F/79°C or 200°F/93°C. 8 138°F/59°C per LPCB NOTE • Custom Finish—Customer to provide paint specification,allow 4—6 weeks for samples. Available Wrenches: Sprinkler Type Recessed "A''Conce6ledPe64ent=V3801,V3802` °'" 4 V384orV38-5 29 01 Victaulic®Terms and Conditions of Sale 1-40.Victaulic®FireLockTA4 Automatic Sprinklers User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic mstallationtassembly instructions standards and project specifications,and the applicable budding codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of VICt81111e Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on aur website at www victauhc.com No statement contained herein concerning a possible orsuggested use of any material, warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List orcontact Victaulic for details, under any patent or other intellectual property right of Victaulic or any of its subsidanes or affiliates covering such use or design,or as a recommendation for the use of such Trademarks matenal,product,service,or design in the infringement of any patent or other intellectual Wctauflc and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending'refer to design or ublity patents Victaulic Company,and/or its affiliated entities,in the US_and/or other countries or patent applications for articles and/or methods of use in the United States and/or other countries. 40.50 2558 Rev P Updated 01/2019 ®2019 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic' INSTALLATION AND MAINTENANCE INSTRUCTIONS 1-40 Victaulic' FireLock"' Automatic Sprinklers 1010 101 .. �a Read and understand all instructions before attempting to install any Victaulic products. *TV • Always verify that the piping system has been completely depressurized and drained immediately prior to installation, removal,adjustment,or maintenance of any Victaulic products. 90 • Wear safety glasses,hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. • Victaulic®FireLock7"Automatic Sprinklers shall be used only in fire protection systems that are designed and installed in accordance with current,applicable National Fire Protection Association(NFPA 13, 13D, 13R,etc.)standards,or equivalent standards,and in accordance with applicable building and fire codes.These standards and codes contain important information regarding protection of systems from freezing temperatures,corrosion,mechanical damage,etc. ' • These installation instructions are intended for an experienced,trained installer.The installer shall understand the use of this product and why it was specified for the particular application. • The installer shall understand common industry safety standards and potential consequences of improper product installation. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure,resulting in death or serious personal injury and property damage. IMPORTANT INSTALLATION INFORMATION • Victaulic®Fire Lock'"Automatic Sprinklers shall be installed 0 DO NOT test sprinklers with a heat source The glass bulb can according to current,applicable Factory Mutual(FM)standards, weaken or shatter if exposed to a heat source during testing. VdS standards,CEA 4001 standards,National Fire Protection DO NOT clean sprinklers with soapy water,detergents,ammonia, Association(NFPA 13, 13D, 13R,etc)standards or equivalent cleaning fluids,or other chemicals Remove any dust,lint,etc with standards.Deviations from these standards or alterations to a soft,dry cloth sprinklers(including painting and coating)will void any Victaulic warranty and will impact system integrity. Installations shall meet Sprinklers that have operated SHALL NOT be reassembled or the provisions of the local authority having jurisdiction and local reused.When replacing sprinklers,use new sprinklers of the same codes,as applicable. type,orifice,temperature,and response. • Refer to the specific Victaulic product submittal for applications 0Inspect sprinklers on a regular basis for corrosion, mechanical and listing information.Submittals can be downloaded at damage,obstructions,etc The frequency of inspections may vary victaulic.com. due to corrosive atmospheres/water supplies and activities around • Transport and store sprinklers in a cool,dry environment in their the sprinklers original packaging.To prevent damage,DO NOT empty sprinklers 0DO NOT hang anything from or attach anything to sprinklers into bags or buckets. Obstructing the discharge pattern will affect the sprinkler's • DO NOT install sprinkler system piping through heating ducts performance in the event of a fire DO NOT connect sprinkler system piping to domestic hot water If construction is altered,the building owner or their representative • is responsible for referencing applicable standards to determine if systems additional sprinklers or other system adjustments are required • DO NOT install sprinklers where they will be exposed to 0 The building owner or their representative is responsible for temperatures that exceed the maximum ambient temperature maintaining the fire protection system in proper operating rating for the sprinkler and sprinkler fittings. condition. • DO NOT install sprinklers that have been dropped or struck by For minimum maintenance and inspection requirements,refer to another object,even if they do not appear damaged Never install NFPA 25 and any other applicable NFPA standards that describe -- glass bulb sprinklers if the bulb is cracked or if there is a loss of the care and maintenance of sprinkler systems In addition,the liquid from the bulb Discard and replace any sprinklers that are authority having jurisdiction may have additional maintenance, damaged or show signs of corrosion testing,and inspection requirements that shall be followed • Before installation,verify that the sprinkler is the proper model, orifice size,and temperature rating for the intended application F.P • Protect wet piping systems from freezing temperatures , 5 • Size the piping system to provide the minimum required flow rate Replacement/relocation of Victaulic®FireLock-Automatic for the sprinkler system Sprinklers SHALL be performed by qualified personnel familiar • To avoid damage,install sprinklers into the fittings only after the with the system's original design criteria, sprinkler listings/ sprinkler system piping is in place approvals,and state and local codes(including NFPA 13 standards). • Per NFPA requirements,flush the system to remove foreign Failure to follow this instruction could affect system performance material Continue to flush the system until water runs clear. during a fire,resulting in death or serious personal injury and • DO NOT paint,coat, plate,or alter sprinklers Sprinklers that have property damage. been altered from their manufactured condition may not function properly and will void any agency listings and/or approvals \Actauli REVS )-40 1-40/Vlctaulic' FireLock'°"Automatic Sprinklers/Installation and Maintenance Instructions STANDARD SPRINKLER INSTALLATION Each Victaulic®Firel-ock'"Automatic Sprinkler is shipped with a bulb 5. FOR RECESSED PRODUCT. Install the escutcheon by centering it protector,which protects the glass bulb from damage during shipment over the sprinkler Push the escutcheon onto the recess collar until and installation Bulb protectors shall remain installed until the sprinkler it contacts the ceiling. system is ready to be placed into service,or as instructed in step 6 on this page W4 1. Inspect the sprinkler for any signs of physical damage and the glass bulb for cracks and loss of fluid DO NOT install a sprinkler • Sprinklers cannot operate properly with bulb protectors in place. that has been dropped or damaged during handling • Bulb protectors shall be removed from all sprinklers before the x sprinkler system is placed into service. • DO NOT use any tools to remove bulb protectors. Failure to follow these instructions will cause improper sprinkler ����� yes ���y. „T4s���� � &• r § operation, resulting in death or serious personal injury and property damage. 6. Remove the bulb protector from all sprinklers carefully by hand before the sprinkler system is placed into service NOTE:Bulb protectors on all upright sprinklers,or on any sprinklers installed r i more than 10 feet/3 meters above the floor,can be removed � _ immediately following installation ,4s;_ MAXIMUM ASSEMBLY TORQUE VALUES 2. FOR RECESSED PRODUCT:Install the collar onto the sprinkler Verify that the collar is tightened completely up against the wrench Maximum Torque Maximum Torque Orifice Size ft-lbs/N-m Orifice Size boss,as shown above ft-lbs/N•m 3. Apply two to three wraps of tape or a non-hardening pipe-joint '/z inch NPT 19 1 inch NPT 40 compound to the male threads only 3/4-inch NPT 20 27 • DO NOT allow sealing material to enter the sprinkler's orifice or AVAILABLE SPRINKLER WRENCHES to contact the bulb or seal. Frame Sprinkler Wrench Style/Sprinkler Wrench Model • DO NOT handle sprinklers by the deflector. Style Open End Recessed Concealed Tee-Handle • DO NOT exceed the specified assembly torques. V25 V27 - - - • Verify that the sprinkler wrench engages ONLY the wrench boss V27 V27 V27-2 V39 of the sprinkler and not the frame,deflector,or bulb. V29 - - - V29-1 V33 - - V33 - Failure to follow these instructions could cause improper sprinkler V34 V34 V34 - - operation,resulting in death or serious personal injury and property V36 V36 V36 V36 - damage. V38 - - V38-4 V38-5 V39 - - V39 - t V40 V34 V34 - - V44 V44 V46 V46 - - - K1 V34 V10 Use any commercially available wrench °3$g �so- , , - F HOLE SIZES FOR ESCUTCHEONS AM Ho le Sizes for Escutcheons Sprinkler inches/millimeters Model(s) Minimum Maximum V24/V27/V34/V36/V40 Recessed 51 608 '�� � �,:= V27 Concealed 60 71 � V31/V33 Concealed 25/4 23/4 4. Install the sprinkler in its intended orientation only.Thread the 67 70 sprinkler into the fitting by hand,then tighten the sprinkler into V36/V40 Plain,Extended,and Flush 1'h 21/1 the fitting by using the proper model sprinkler wrench(refer to 38 63 the"Available Sprinkler Wrenches"table) Verify that the sprinkler V36/V40 Sleeve/Skirt 13/4 21/2 44 63 wrench engages ONLY the wrench boss of the sprinkler DO NOT 24 „/ 2 ,b engage the sprinkler wrench on the frame,deflector,or bulb To V38 Concealed 60 68 obtain a proper seal,tighten the sprinkler securely to prevent leakage.DO NOT exceed the maximum assembly torque values listed in the"Maximum Assembly Torque Values"table �ct_au lilc" 1-402 REV S MAP 0 F MATTITUCK SHOPPING PLAZA. SI T UA TE MATTITUCK TOWN O,F SOUTHOLD SUFFOLK COUNTY , NEW YORK � � s S . C . TAX No . 1000 - 142 - 01 - 26 o a: 0ON "�° SCALE 1 " =30' s NO, JUNE 49 2013 cONp. 9\^°G 0., OCTOBER 21 , 2019 UPDATE. FEBRUARY 7, 2020 UPDATE s AREA = 381 ,014 sq. ft. 8.747 ac. 55OCIN F / CEME�EgY P o. gE ryry. � •o. n 0 11 't o. �O \ 603 's. \ �F 'O. ea, •� ypd 00 dr( 0 00 5 G 3 $ gyp\ \ \ S-06 `\ �\\ m \ o m�j \ Gi \ O o'� 3rO O�0 �y 4 JQ Z ` AO. \\\ \aGyy 0Q�• Z �P� 0.04 \fir \m �O `•� i V O �i3ONG Sg0\lp�p `\\ '�/���G•GVH \\\ /// /6 \ ��O 103 .45 1M ///f�'e�'l0� \ ` 12a' .5' \6 °\ O l\\\o;per oy m �.o ry�°a �GA\G i-511 / 21 Y O\ �' oe- n� OS G0��Qi'(�\ 1 OF JNE�� � G°�� G 4 \ G•5 S \ d G I t^ CURB y 3 BOLLARD m O� CUT ,P �o tic yy A �m C �@ /c�+YC, ° `4 c� y S oG�m �G•�e- oZ n �m G°�G GJe0 �6 0 CO QP VO. GO tic CI °oti XS,� cG.Pm 0" n do V1 0 LIN.A 70 � C--) 0 o„ PREPARED IN ACCORDANCE WITH THE MINIMUM STANDARDS FOR TITLE SURVEYS AS ESTABLISHED BY THE L.I.A.L.S.,4ND PRO ED AND ADOPTED FOR SUCH USE BY\THI N4Y YORK.STATE LAND TITLE ASSOCIATI04." P, 0 0V 0. N.Y.S. Lic. No. 50467 TO THIS S12 URVEY ALTERATION OR ADDITION ` Corwin I I I TO THIS SURVEY IS A VIOLATION OF imathan SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. LSurveyor COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN Successor To: Stanley J. Isaksen, Jr. L.S. ONLY TO THE PERSON FOR WHOM THE SURVEY Joseph A. Ingegno L.S. IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND Title Surveys — Subdivisions — Site Plans — Construction Layout LEADING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI— PHONE (631)727-2090 Fax (631)727-1727 TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE. THE EXISTENCE OF RIGHT OF WAYS OMCES LOCATED AT MAILING ADDRESS AND/OR EASEMENTS OF RECORD, IF 1586 Main Road P.O. Box 16 ANY, NOT SHOWN ARE NOT GUARANTEED. Jamesport, New York 11947 Jamesport, New York 11947 99-677H NOTES: FIRE ALARM SYMBOL LEGEND - NEW DEVICES SEQUENCE OF OPERATIONS MATRIX FIRE ALARM WIRE TABLE 1. GENERAL INFORMATION SYMBOL DESCRIPTION MANUFACTURER MODEL NUMBER QUANTITY SYSTEM INPUT SYSTEM OUTPUT SYMBOL DESCRIPTION MANUFACTURER FPLP MODEL - INSTALLATION OF ALL DEVICES, WIRING AND CABLES SHALL COMPLY WITH LOCAL ORDINANCES, ALL NEW YORK STATE CODES AND NOTES: W1 16-2 TWISTED SHIELDED ' HONEYWELL GENESIS 4606 ADDITIONAL SUPPUMENTS, NFPA-72 STANDARDS, MANUFACTURER LISTED DISTANCES AND SPECIFICATIONS (AS APPLICABLE). FACP FIRE ALARM CONTROL PANEL FARENHYT IFP-300 1 - ALL STROBE APPLIANCES SHALL CEASE TO OPERATE � W2 14-2 TWISTED HONEYWELL GENESIS 4513 - ALL KEYS AND RESET TOOLS (PANEL KEYS, PROPER SIZE ALLEN KEYS, ETC.) SHALL REMAIN ON SITE. A AFTER SILENCE FUNCTION OCCURS. Z o - EACH CONCEALED DEVICE SHALL BE ACCESSIBLE FOR SERVICE AND HAVE A REMOTE ALARM INDICATOR. EM - ALL STROBE APPLIANCES SHALL HAVE A o Z v W3 18-2 TWISTED HONEYWELL GENESIS 4602 O REMOTE ANNUNCIATOR FARENHYT RA-1000 1 - EACH DEVICE SHALL BE CLEARLY LABELED FOR ITS RESPECTIVE ZONE, CIRCUIT / ADDRESS. SYNCHRONIZED LIGHT PULSE OUTPUT. N = Z W4 16-2 TWISTED HONEYWELL GENESIS 4511 - ALTERATION AND / OR CHANGES TO THE FIRE ALARM PLAN SET SHALL BE PROHIBITED EXCEPT UNDER DIRECTION OF A LICENSED -MULTIPLE PATH COMMUNICATION SHALL BE WE EXISTING WIRE TO REMAIN ENGINEER OR THE AUTHORITY HAVING JURISDICTION. OS SMOKE DETECTOR FARENHYT IDP-PHOTO-W 32 SUPERVISED WITHIN NOT MORE THAN SIX HOURS. N o HVAC UNIT SCHEDULE & TYPE - EACH DEVICE SHALL BE SUPPORTED BY THE STRUCTURE USING MANUFACTURER RECOMMENDED UL LISTED BACK BOXES. -SINGLE PATH COMMUNICATION SHALL BE SUPERVISED ; cm ME w CL - EACH DEVICE SHALL BE SUPPORTED BY UL LISTED T-BAR STYLE HANGERS WHEN MOUNTED TO A SUSPENDED / DROPPED S SMOKE CO FLAME HEAT DETECTOR FARENHYT IDP-FIRE---- -CO-W 4 AT AN INTERVAL OF NOT MORE THAN SIXTY MINUTES. o o ��' TAG C.F.M. TONS TYPE ROOF LEVEL -- - -- --- -- - ---- - --- ------- CEILING. ! AUDIBLE BASE FARENHYT B20OS-WH c� Q cr: RTU-1 2000 5 PLENUM -Mn FWEAND DECK - THE CIRCUIT BREAK BREAKER NUMBER, PANEL NUMBER, CENTRAL STATION ACCOUNT NUMBER SHALL BE CLEARLY POSTED INSIDE _ n Z Wo �°�C°`NG s��cE ``�" °° `' � o Q 3 z RTU-2 2000 5 PLENUM THE FIRE ALARM CONTROL PANEL DOOR. F] MANUAL PULL STATION FARENHYT IDP-PULL-SA 4 `�' Q o - A 24 HOUR EMERGENCY SERVICE TELEPHONE NUMBER FOR THE FIRE ALARM CONTRACTOR AND A 24 HOUR CENTRAL STATION z "' RTU-3 2000 5 PLENUM 1 0 CONTACT TELEPHONE NUMBER SHALL BE CONSPICUOUSLY POSTED ON THE FACP. RETURN DUCT SMOKE DETECTOR FARENHYT IDP-PHOTOR 3 N N - MAICONCRETE N LEVEL 2. FIRE ALARM CONTROL PANEL COMMUNICATOR AND REMOTE ANNUNCIATOR INFORMATION d)R -- - - - _ - — W N Z - THE FIRE ALARM CONTROL PANEL SHALL TRANSMIT ALL SIGNALS BY A UL LISTED COMMUNICATOR TO UL LISTED CENTRAL STATION. DUCT SMOKE DETECTOR HOUSING FARENHYT DNR m o c� o - COMMUNICATION METHODS USED TO TRANSMIT SIGNALS TO SUPERVISING STATIONS SHALL MEET THE REQUIREMENTS OF THE FIRE ;/ REMOTE ALARM INDICATOR LAMP FARENHYT RA10OZ 3 o ip- TYPICAL INTERIOR CROSS-SECTIONAL ELEVATION DETAILS CODE OF NEW YORK STATE (SECTION 907.6.6). / \ "' NOT TO SCALE THE REMOTE ANNUNCIATOR SHALL BE LOCATED AT THE MAIN ENTRANCE. 1 MANUAL PULL STATION • • • • 3. SMOKE, HEAT AND CARBON MONOXIDE DETECTORS aM ADDRESSABLE INPUT MODULE FARENHYT IDP-MONITOR 3 1 SMOKE DEFECTOR • • • • - EACH DETECTOR SHALL NOT BE INSTALLED WITHIN 36" FROM AN AIR SUPPLY DIFFUSER, RETURN AIR OPENING OR WITHIN 36" PLAN NOTATION LEGEND (NOTE: SOME SYMBOLS MAY NOT BE USED) HORIZONTAL PATH FROM THE TIP OF THE BLADE OF A CEILING-SUSPENDED (PADDLE) FAN. " AOM ADDRESSABLE OUTPUT MODULE (RELAY) FARENHYT IDP-RELAY 3 3 DUCT DETECTOR - RETURN DUCT • • • SHOWN AS DESCRIPTION SHOWN AS DESCRIPTION - EACH WALL MOUNTED CARBON MONOXIDE DETECTOR SHALL BE INSTALLED A MINIMUM OF 80 ABOVE THE FINISHED FLOOR AND AT 4 CARBON MONOXIDE DETECTOR • • • • 01 SUSPENDED PUSH-UP TILE CEILING SOFFIT / ELEVATION CHANGE LEAST 6" FROM THE CEILING OR AS SPECIFIED BY MANUFACTURERS SPECIFICATIONS. 5 SPRINKLER WATERFLOW • • • CEILING MOUNT AUDIBLE STROBE - HEAT DETECTORS ARE NOT REQUIRED IN AREAS PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM THAT IS CONNECTED TO THE mc (CANDELA SPECIFIED ON FLOOR PLAN) SYSTEM SENSOR PC2WL 4 6 SPRINKLER TAMPER SWITCH • • FINISHED TYPE CEILING (PROVIDE AN ACCESS _ STRUCTURAL I-BEAM (NOTE: ONLY STRUCTURE BUILDING FIRE ALARM SYSTEM AS PER THE FIRE CODE OF NEW YORK STATE SECTION 907.4.3.1. 7 SYSTEM POWER FAILURE • � • � HATCH FOR DEVICES INSTALLED ABOVE THE CEILING) –� — e� IMPACTING DETECTOR SPACINGS SHALL BE SHOWN} 4. MANUAL FIRE ALARM PULL STATIONS WEATHERPROOF WALL MOUNT AUDIBLE SYSTEM SENSOR P2WK 1 - THE OPERABLE PART OF EACH PULL STATION SHALL BE MOUNTED 42"-48" FROM THE FINISHED FLOOR. ° ' STROBE (SET TO 75CD) 8 SYSTEM OPEN CIRCUIT • • EACH PULL STATION SHALL BE LOCATED SO THEY ARE CONSPICUOUS UNOBSTRUCTED AND ACCESSIBLE. \ / ; CEILING MOUNT STROBE 9 SYSTEM GROUND FAULT • • Q3 NO CEILING - OPEN TO DECK ---------- HVAC ZONE OUTLINE - EACH PULL STATION SHALL BE LOCATED WITHIN 5 OF THE EXIT DOORWAY OPENING. SYSTEM SENSOR SCWL 8! CANDELA SPECIFIED ON FLOOR PLAN END OF LINE RESISTOR _ _ BEAM DETECTOR PATH - A PULL STATION SHALL BE LOCATED ON BOTH SIDES OF GROUPED OPENINGS OVER 40' IN WIDTH AND WITHIN 5' OF EACH SIDE ( ) 10 SYSTEM LOW BATTERY • • (PER MANUFACTURER SPECIFICATIONS) (MAINTAIN AN UNOBSTRUCTED PATH) 5. THE OPENING. �� HVAC MOTOR STARTER FURNISHED AND INSTALLED BY OTHERS 3 ®--—� RELOCATED DEVICE HATCHED AREA NOT IN CONTRACT 5. NOTIFICATION APPLIANCES - AUDIBLE DEVICES SHALL BE PROVIDED SO THAT THE FIRE ALARM SYSTEM IS AUDIBLE IN ALL PARTS OF THE BUILDING. - THE BOTTOM Of THE STROBE LENS OF ALL WALL MOUNTED STROBE AND AUDIBLE STROBE COMBINATION APPLIANCES SHALL BE p SPRINKLER VALVE SUPERVISORY SWITCH FURNISHED AND INSTALLED BY OTHERS 2 AHJ STAMP BOX MOUNTED AT 80" ABOVE THE FINISHED FLOOR. - ALL AUDIBLE DEVICES SHALL HAVE A TEMPORAL-3 CODE. 6. HEATING VENTILATION AIR CONDITIONING (HVAC) INFORMATION ® SPRINKLER WATER FLOW SWITCH FURNISHED AND INSTALLED BY OTHERS 1 - EACH HVAC UNIT SHALL SHUTDOWN UPON RECEIPT OF ANY FIRE ALARM SIGNAL IN ACCORDANCE WITH THE MECHANICAL CODE OF NEW YORK STATE (SECTION 606.4). W2+W4 - REFER TO HVAC SCHEDULE FOR UNIT INFORMATION. FAA W2 W2 7. SPRINKLER SYSTEM INFORMATION \ / - EACH SPRINKLER SYSTEM DEVICE(S) AND/OR PUMP(S) SHALL BE MONITORED BY THE FIRE ALARM CONTROL PANEL. S S S 0 S S S S 0 S S S / \ S S S S S S S S S , - THE ENTIRE TENANT AREA SHALL BE PROTECTED BY THE SPRINKLER SYSTEM. WP W2 S-21 s-22 S-23 S-24 s-25 s-26 s-27 s-28 s-29 s-30 s-31L:JR s-32 s-33 s-34 s-35 s-36 s-37 s-38 s-39 L � l O N3-1 �Z 95cd 15cd W2 \ / W2 \ / cd 15cd \c� W2 W4 / ° /°\ /°\ ° /°\ S S R S S S S S S S S S S S S S R S S S S S ci N2-5 N2-4 N2-3 N2-2 N2-1 S-1 S-2 S-3 S-4 S-5 S-6 S-7 S-8 S-9 S-10 S-11 S-12 S-13 S-14 S-15 S-16 S-17 S-18 S-19 S-20 15cd W4 75cd WAC WAC HVAC w uFlk VS 15cd 15cd 15cd ICI 15cd 15cd W2 ILEI0 0/ o�o/ O \off o/ AOM F AOM F F AN F AN AM AIM c / \ / \ / \ c N1-7 N1-6 N1-5 N1-4 N1-3 N1-2 N1-1 M-1 M-2 M-3 M-4 M-5 M-6 M-7 M-8 M-9 M-10 TO 120 VACFAC P TO CENTRAL STATION AS REQUIRED PER THE FIRE CODE OF NEW YORK STATE SECTION 907.6.6 TO GROUND F-1 RISER DIAGRAM I STORAGE EXAM EXAM EXAM EXAM OFFICE MANAGER L STORAX CLEAN ROOM OS O S S S j OS Q O O CONSULT CS — s-12 s-13 s-1s I S-18 s-2o �- s-21 15cd M-4 - S-7 N2-1 m NM � AOM / \ 15cd IT ROOM TT S HALL S S \o/ S-22 ON2-2 M-8 M-9 M-10 S-10 M-3 S-15 S-19 N2-4 - - - -TOT - - -- t WAITING �! �t^� 1 1 )r PHYSICIANS OFFICE MED ROOM O/°\ EXAM OBGYN) EXAM I EXAM RECEPTION 95cd S-11 N2-3 �! O S-36 - -- S-32 S�4 S�7 S-24 c -� O Iz O O O O LOCKERS s-5 JANITOR-- ' N2 5 i RN-1 \ — W jil WIC �--�R RN-2 \ ---- 15cd - - �, - i REV DATE DESCRIPTION PRO EER TOILET M-1 s-2 i / v - 1.0 1 01-07-21 PRELIMINARY RELEASE - CLIENT REVIEW `� Y ii 15cd F-' /°v �S AOM S R HALL S � A.0 01-07-21 ORIGINAL RELEASE ° " \°/ N1-4 "EE 5-35M-6 S-31 5-27 N1-7BREAK ROOMz TOILET sf3 Nth75cd PTOMY - f - - S 15cd \ / -- 0 O 5-23 S o �� - CARE LAB -TOILET _ / EXAM OBGYN - O \ 1 c EXAM EXAM EXAM PICKUP 5 d 15cd EXAM _ EXAM S 1 N1-3 ) N3 1 � � M-5 S 1 �I 4 N1 i S O o N 1 S S O S S 5 � S S o i II' S S -o • 0 4 O . 7 O ' _ O O O O O O S-39 S-38 S-37 N1-5 S-34 N1-6 S-30 S-29 S-28 S-26 S-25 pROfP�� M-2 M-7 ESSION -_-_ __ -- -___ -__ -_,. ' INSTALLATION CONTRACTOR: DESIGN & DRAFTING BY: ----- - I - -- -_ - -I - - _ - -- I �- CHECKMATE SECURITY SYSTEMS, INC. FIRE SYSTEM DESIGN PROJECT INFORMATION: 1055 STEWART AVENUE, SUITE 12 STONY BROOK MEDICINE 65 JOHN STREET BABYLON NY 11702 BETHPAGE, NY 11714 10095 MAIN ROAD ROBERT - 852-6443 GRU ENER: 516 MATTITUCK, NY 11952 NY STATE LICENSE NUMBER: 12000017610 FIRESYSTEMDESIGNOGMAIL.COM MAIN LEVEL DEVICE LOCATION PLAN SECTION: 142 BLOCK: 01 LOT: 26 LICENSEE: RICHARD DENNER GARRET GALINDO: 516-557-7892 SCALE: 8" _ V_Q' OCCUPANCY CLASSIFICATION: B NASSAU COUNTY FM NUMBER: 943410 GARRET.GALINDOOGMAIL.COM CONTACT: RICHARD DENNER PAGE NUMBER: JOB NUMBER: TEL: 631-669-3303 FAX: 631-669-7259 -?1-01 art d __...._._.___ 11_11___."._.,.>:.__,_ _ - ,,..:.____...:.,_ S� 2 i< . a.-..t i I' _. .. -1111.. ............._.._..__1.111... _ ..... ....... . .__ 1111 / i I I ­1 , � I .1 I ;�. .. 1111 I TE 2 i ii I ..--_.. 1.1.1 _ _....I...................... .. ... ; e 2 :'` I. CATION OF^EXIST1NO�ROOr-TOP•6A5r-IR t3-A04 ,VNIT1S--A3- 4 .: f: DEC 1 3 r�:;';� ( ) L_ - - - _ I LA� 15 RESPONSIBLE TO FURNISH AND INST _Nee&6 FIRi�D I ' . . V � - t T 8001=1'OP AG JNIT. REFER 70 M1 GHANIG" LES AND (80) I'll SPEGIFI TIONS RESPEGTI Y . _- GA ` 7N._ 1 401 A 1/EL I I .i �V VD 2x5 12xe f"n- f . ' 2. NEW GILIN� 'EX�ht �TM AN ^ttT°t' XHAST T3t»fGT»t �" 7C7F=. . ... .. �° .� � AIL ON L7RAWIN6 r ' !, I : 1. TO DET I :i . i i: ii ._ 111.1_ .__...,.p..__<__...._._._�.._. ___- ____...._........._....... .....__.........",,..-__-_--_._.",._....._._.".____.__.............. 1 ...,_ ' 12x5 _ ., _.. _ _� _ �' _. d + ., p °� 5 -- 12x5 .� t r \ - 1.111 _ i 1._// 111-."--------1111--_...._... »». ,„« m... m 1.111 1.111.. '•{ ...' 4. ,u�,s'^.... ..__! 's<.�"`;...` >�.r«_ {,is,.< .- s'� .. 111,1.1.11.1. ._. ____._____._ ._m __ ,1.1.1.1. _ , ' 1 ___.._..___ a� # _ X5 .. 1.11 1... _ _ ,,,- 11. " 1.11q I 12 __ 1111.. ' f 1111 _ #f/ t : t _ _ A _ . . _` _ - . _ _ & ." __11.1.1._ t5o) : ( ._�_ .._ ._.,_,. _ s � � � I a p ( ---- 1-��&,k�c � p h __ _ _ _ 1.11.1.,_ .__ ___ .. . �._.__ ___ -. _.. ___.__..._._. .._ .. .._ __" 111.1. __ __ _,_ 1.11.1. _.__.__._ _ _.__.. ..__._ ._ .__, _____...._. __ }: }jjj �. 1 C:. , �. ........1.111._.......__ .. L�rg : . 5 € o. _._ _. 1.111 1 � � >:: ....._ ... . .: .. _1111. _1111......,..__... _._ -. . . . . _ ", . .. . : � . 2 0 _ -.. a l t. �� � � _. ,_ 1111 1.11.1.. " t - { » ,. { t ". � . "� ��" 1111. . . .. > d � gk _. , 1.,111 ... .. .. . , a � � __._..�._______.__ ._.__._._._,.......... .. .,...... 1.111.._ 1111................ ...._-._..,._.... ....,_...,._.,- . ..,._ .. _ ........... _.__ _ ___ ... .. _. ... _ .._ 1111..". .. _._... .._..._ ...................... .. 1.111.. . _ _._._......__._... ._.. 1.111,._ .. , _.. _ 1.111 . _.. 'FA 1.1.1.1._. _..."....,.__ ri . . I to � .� -1.1.11..._ .. _11.1 ..1 111.1__. .__.1111._. „ 1111._ , � ._ __. .._ , _._....__w .._____.__11.1.1_ 11.1.1.__1.1.11.. 1.111. . � _' � _. < . . � , e��» t st _ _ , .. 1.1.1.1 . . _ . ___.__.. . 1.111. 1.111__ ,1111 �' _. 1 t ( __�-- _...._,--. 1_._.111-111 1.. �;�.. � .,1111_ _ _---__________._ g-A mit " _ ,_- .1.11.1 a �� . _ __..._._. .. .. . .. .. .. . p 1> -11 .� _ _. _ � tP � rC `� M .. - " ___ C °" :_ -_. T _ 1.1.1.1- __ _. 1.1.11 i -I -----, 11-1-L- ___ ' tF� 1.1.11.. .__1111. H _._. ...,_ "._. :__._.� :1.111.::: ___w _ :w.w. _._ w - 1.,1.11. �..> ,.. �. ��w=-� ," 1.111._ ... : -11--,_.-_..-_,-._...._.._._. ....._.. _. _., _5' '___1-1 1.1 111,_. 1,.11.1 . .- _ .._1 1. . 11.,..._.._.._1..,-.1.._.___,.__.�._...._.-"__ 11.1.1 .,. 1111__. " , ._. � _, .,� 1111. ,� . I h_ .u., 111 1 . . . . __ _. ._.. _. ._._.._._--.._._._._.,.-_1.11-,1111_,-.__ _-. . _ EXISTING ENTRANCE PLAN � .A=CT �- �: ._,-___ ,-µ�--------_.-,- "____. ---- - __.__ ... _-__ _ __ ._ �� _ I ��` _ _ 1.11.1. J 1111. , .�.. 1111. _ � -.......... .. . . 1111. ._ � ', ' �. yy yy� ``pp,� 1 '/� � .cam U 6""'i 6, i i I, i I I __- .1 . :1::: 1: ::11...:: : : ., .... . (Di __ __ i '.a i � ,k r 111., 1.111. _ .. ..11 11._'_.�.,f__...-..._ .._...__....,i.... .. t . . " € ..» p� ."« ,.<°'� a Q,� i o . .. .. _,.._ ...1.1...... a , , ,« .3 1 EXHAUST DISGHAR6E .. 1. i, 1111.. :" {;; I i yit AI:3DYE hN1NO GEILINcS t / Zi,I ( } 65) 65 r; _., . ---- ,.. _. II ._ t li ( ) /', 65 .. 111:1: _ . ( J ao , _ . _ i # .. _ _ _ tt ` I! i f i •�... 11 i E,..,'Zf:.. _ _ q a "sa ['� 5,.+. `..�+� I', _...1.11.1. .... .. .. . . `f .....»,<..,. »..� 1111-.........r_ ' "Su r E .�. ..» 1111.,_ 1111...-> 111,1, ` �< il + I i; .» ' ... 1.111.. 11.11.1111._ €a «. _.._......_,_.._....„.„,„.�„." .,.:,< .. kC..€ 'a 'g . k .. .. , <... , , .1111..1.111._ 1.1.114a� »3 d3'..` 1 . 17 :; qi m 11 t k, L: . 1 a' _._. 1Zi > ._ p I : r _ _,. ..._ ....�_.;�.� .�»._. 1.111 Mme._ w.:�., * , Car i' I � Yb �1 I �a . - =r " w._....." "..",...eu....��. . I _ : 11 1.111_. ", ."..,.�_::.. ..<. . 1111,., 11.11 _ :���. - :I n `i 1111.. ... „ .w...,..Yaonc�oa.. �w .....1.11.1............ 1. , 1 . . _. : �C� 1.111 .. I. I 1111 .. r 100 . ( ) . I. I : !'' \ : , ! ,it I; \, �i .. _ ... .. ... .. 1111. '. i R RTU ><.-,., ;- ._. .. . .. .. . .. .. :> , :-1«111.. i .- I .......... : I F.�.. i ;: _.. g" I t -. -. ..i > "i ,.< ,xwma�s-..I I /�:q "," .. .. •�. . ..... t�^'"�.�',`# .._ .. ».> ; : ,_ .`. Y v 1111.. ...:--..1 .. .. ._. _ ... ..r r I .:.. . .. VI7 , ! i.n..} : L 1. 1 , »- - - - _ _ T ( } - : Q : r Vp Yt7 .� - IG , 1111 ,. : /..: f f, ; : , .., 1111 ., ;1111- �i :' '-i,: I$ I I +AGOUST 1/D 1,1: . -.. .............:....... ......... _. , : iN ,. / N _ ., . .. ., 111::1. r 85 I '` . 111 6 <., ,: t` } EF 2 11 .• i • 1111 T 1 r i : I I i � { I I I 2 2 i r (w).1111 ,' .. 1.111 ,. : . t ' L 1. II ! : I T, - - - E a q�. ' TU-i . �A - . r { 41 I _ _ _ '- i 1111 .. � � I 20X12 _ "' _ . 1, t �� .. . { .. ; -_4 I Y1. 7 . : : I , f .. ! !, i ai , tr I i 11 /` IV .r" r` .. 1.11.1 _ . . �� I .A�.OtJS G 1tD. .. . . �� _ .. � _ _ . 6 ( INI1111 1111. ., a 111.1 ... .111«1-..>"......... .,.,..._..«.».....«' >"�., - _ ... ._. :., , .. ... .._ .. _.. . Y1/ iq- �.r : : : , .y -......<..�.....--, ._--'111`1," w__..................�..- .--..,.......,_,....,..�r......�..- 1____^..,..,.a__1i"._._ '° :' r .... � . .. _ . a v Yt } .�„<." ,. .. 1111 -.. ., ., .. _ .. 1111 .. > _ ;�� I X D i 1111 ... _ _� 1111. , I . . v .., 1.111. Q . /, } / , 1111 < < < :' ,. 11.;11,. :1111 _. : 1111... r ..- .- ,. . . '�' I d . r r. 1111 ......... `�V\�., ;'r. ! , ,:.._ .._ .......1 . .. .. . . . i, , __ , fr ".. f< i : i r , 1111 , : '� I r, 0 rs. j . _ _..-_ . . _. _ • 11 i ir a..+°� C'' �"' ft , .,q. » ! •'r i .. _1111.............. 1111. ' i IE .. ... ",ati.m,.wa. ! ., i i _ ✓ t �anti 16X 12 `•, , .. r. ii , - 1111 ...A . . - . - F - , �: �1111 t t: 24x12 �� a __. .. ..._ , ; I Ia , 18x12 Sxt2 , !6x12 16 12 XIS ,,�-I�XI ,,�-12x1cFi .'"14 -12x10 !I ` t s 2X5 t. :' .. i li ., _..__.._ _. _..r...r,., r... t ° ii I -.1 i. ON 1/D € tr I 1.1.11. : . . t° t \117 ! . 1.111 _ _.. . . '(.� a. . i 9 1 1111.. : „ : ... ^?^F / ,g i LC'.I •; i } i gtt I >,. f I%: R I :. . vD f �J . , et M� I I , I , l ., ' ' i I I rj i ��C:OUSTiG c f ,, a I{ : . 10D , � . Y i d. KE alt s I . . ........ ... I _ Y PLAN '� tI Vfl . : i 1._.. lL IN6i ( ) ,, : ! . . . . ..i... __ _11._.1.. I . ,_ .. : . .: 1111 (52 INFO �' �l . ,,. ,i. : „, 1111.. g - . . I : .. < a _ t.. .� I 65 ( } (QO) __ , , 111.1. b . 1.1.11.. . : ;a . , „ ! t i 24 12 1.111 „a ,. !. 1111 ... , , , . :: i'.` c�. 65 �I -°< I II } 65 1111. 1.111.. ( ) { i.. t i 1 : f. k ... II fl •^vx,,, .> 1111... : : .: , t ".waa , : , 50 I (1 } (( E 1 t✓d.a 1 I 1/Dii i ,I . . �' :. ., r .. r, VD it �, , , .. .. t >. , t , r. .. �. : ., ... 1111 1111.. , r ;. i .. i1 - .. ... .g 1111 .. .. .. .. .. ................ I � � � � ) _. ... 1111... , II ' � _ _ _. :! I _ _ (75) ..... ...11..1. 1 .....,. ., _.1. ..e i. is r"" ""I !.',; i ,,.! .,. 1111 .. -- _._ RTU-� `.t'-' - - "t� ```� '`" ; : I 1 A+ of a 1.11.1 , 1 PRP-MAN is ii -n : - >. ./' : :, : .. € . 1111 I } fj ,p)y i. .. :1111. �^ 1111 . .. "i y1 Ii•+" , i !. !: i r. , t F >,..savrau:...>., / .i ... 1111_ .._..... i, 11111. I. " i, : , ; i _.. a. , i :: > . 1_, e l _J _ g._ t j 3 i j .. > <. > < <. a..1.111 ... .. ... A'� m j;. „ ,. I , .. .- 1111 i ( v.. ,. . . { F /. ,. ..1111 _ L q I 1 . E �_- .. .. r..._.. .. .<.. .,, ,. . -.. _.. . . .. 1111. .. ..... .... 1111 i l.. i ,. W.,11:11. ..e_,_f.. ....d J .. t <' , x .. ... < � ^^_.•✓.[ M .. .. ... : ..t _:. 1111. 1111. .. �y d�a� p 1111. . 1111.. .-. ,. .: 1111 b 1.11.1 _ 1111 C NOTES 1 2 i I `�T BP151 I i \ ii _. . .:...... . . . ... ... ... .... I : : << i . ... . ._ i d .. .. 1111 1111. .. .. .. .. , •*a 1 { ... .. ,. ... ' i• .. .- ,. r. .. ._ i .__I_, -. , 111 1.. ! .., 1t ..'. ., .. ., .. .. i'i �`y,'�y 1111. v rram '/ 1 f; rJ NOTEra I +1 2t IUX6 '' U �' I : '. I x€ 11 ki : . .: L ... _.. ._ 1 ' „ ! i " ;._ li ' ,! _ i , I 1 ,. 1111 1.11.1 I I . . . ... .. . ... .. . .. 1.11__1.. ."__ _. ........_::._ .. 1111... r g .. #� .. ,\� uT : a� l a V. a it N : , ... (250) RTU-2 1 ,.SL at t ; 80 I 'I .• 1111. ,. < : r 1.111. ,.. t 1111 _. a ( E 1.111. , i I O '� w._,.._._,. _ . . . _,_�_._..._,_„ 1111-.._._.._. m, 1.111,. �., .. �._�..�. (8G.} { .. . -- _ 1 : "�1 t , i . .. .. , I +�. : rr .. .. 1111... , :. 1111,___,._..<._. 1111 .-1111... ._w�_...............__._..._.._.."_w..... .. 1, .,...>.,.,.,, ._.____.___......___ ........_.. _. ( ) i r, . , 1 TIG IHINiS.,r, 'f .:: � : 11.11.. . i „ r,"? ,I.. .-,, .. 1111 < , ff. .<. < < - `v�/ ii , ., I =� .. .._.1111..1.111._ .. . . . , /. 1. 1111... _..»... �. ... 1111 .. ! , ... { ..1.111... i RTU- , -. 1111.. :. ...,.. _......._.. ., ,. 'i'i l, •�-Y•.• +- II 1.111 .. ill ,/ 1111 ....,....._._... L.r..,I'1..., , < .. :. : .., T 11 _1111. 111.1. f f-... 1111 c 4X1 i'� i ! 2 , 1.111., PR il i ±Yt;77 ,< 2 It, PROJECT 15x1 24X!2 t,. - . `/t Y; v. x2 I 1 �_ , 12X3 I x i . ii 1X5 11 11 - -1111 - - - - - - 8 12 X12 , - - - - - - - - - - - - - - 1111 _ _ - - - - - - - - _. ._ -- is i - - - - _ - - _ ._ . - _ � - - - � _ V» : TONY �R _ 12x5 12x5 � I .•...._..... . ....... . __1 [ � ; . I A TIG - -: r I A �,. ' : tilk 7 11.11 [ff� }�^»' ��''y{ I. 1�.. Xl'S1. _._ ... .,1111 / : 1111 : , 1., ii �_. .I-. "n 1 » 1111 ``n , 1: ' ✓, r L ' / I » 2x5 I, r•, I ..: % i I } _ MEDICAL : I . :, itCH y. I , ,., EI : ; 'VD , i _ , _ 1 , __ _ 1.11.1. _ r. % �; I vo r' , i (525) 10095 MAIN ROAD .. ij , .,:a I- A �. //11 ii t r/" :, :. i,... ... ........., ._.._.ai._._...... .......__. 'i it !.`i i 1 V, Y br/ : :: ' I 1111., '` ^, _.. 1111 ... _..._. ........ _1111.. 1 i VV i I 1: .. .__. .. M NY 11952 , C5 ! ATT U ,'. •, P � . 12 I ;; i _.. ` = f' WQm i > 4. :i ;,. .. s , ate a I f I . , ,. 11 11.1.1......... r. .. ._ . . - , "t a ; i ;, a v .. . . ... ... NEW y DRAWING TITLE r _; _. I . _t i;!r : I'''. r I !,A F .. , i! i ._ i ; ;! : : : < : I ,'.' : .. : { ' , it : ii ss , " i i. r 4 3 « +„" ¢ I EER i' ii t F ------..-- : . r : : .� ( ) (5 ) 100 ! i ( ) . O . i• I i I } fro) h0) 5 , : t __ 1111. : i I ' t i 11 . ......_ 11.11-„ r l - - ---.-' { ��� � 11 r d { t 11 , 1. ( I . 111w , , 250 i 1 250 i I (80) r i a ..� . . 1111 .. !.I 11.11 ._i : d , _. .: , ,.. .. .. ... z IN, "I .. .. 1111....... .Y ... .. i. 1111 _. .:'/."..._._..__....,__..,.._._... : . 2 ,. ... , .......__...................._..._-__....._.....__._.._..,......,..........., u u ..111.1.. ., .. € 1111, ,, ...11111111 .. .. -....".". 11.- ._.__...__..._.__„__ . \•' r'- f J Is I ! ��. .�1111. 3.. .... J i 1111. .... 1111. ....._...._._ 11.11... .. .. , f I i i_ .r T ��NO ? � , :��3 R BYPASS Ox ISPs-I NOTE 2 � .w, � ,• � � _. _ _ _ 1'�- fi day>.. , � `� ! SCALE t4k �► � � (IS25 GFta'U , A � ' F .. t t AS SHOWN 11 _1 �, � ? �� .< a � DRAWN BY . '_ <� R TO DETAILS 201 " a �t.. ` �� c � :.� _. ... � � �` � DRAWN FOR .�ET u� _,, _ - „s r IDT __j ik �. .e ..�.. � CHECKED BY ,� �. g , �} 7 _ i% "�y�� �1cakcs �.I'll»....,...- t .`.z� ,�,�..,,.�,»1111 PROJECT# 0 021 8' ,,�� 1.1.1.1. :w _ __ __.�____._�._.____----__-__•-___-�. ..._�..._. -- ---- __. __._._.:�__.._.�1.1.1.1...._ ___ .__ -. . -/ m " 1111_ 1111 .., &................ � ..._........++ �,,,., ,..._.., A --_............_.._........-v-_._....... ., �INIIINIIrr1�N�NlOri '�'"A _ �, _ 1.111__. _ _ __. __...__.�.::: ... ....SHEET _... _ , �� _ .._ No._ . .___._..._._ ____._____.__.____-111._ .. _. .� ��', fftw>-," t -_--".______1.1.1._.__1-.m.�._..�,__-.__. ,.�."_.,.... '' _ � �. �K.�>....,00__ _ _ �•�_-_ �� .::___:�ww��-"m.. `._..,_ .. - ...... q 3� o» W w I . D NO. REVISIONS DATE BLOCKING SCHEDULE ! li WALL TYPE LEGEND ADDENDUM 1 8/12/20 PLYWOOD BLOCKING AT: 1 i (E) EXISTING WALL TO REMAIN 1. ALL CABINETS 2. TELEVISION r I ■ NEW WALL (SEE TAG FOR TYPE) O 03. BATHROOM ACCESSORIES ' ,i 4. GRAB BARS EXISTING DRAWING LEGEND MEN'S 5. WALL MOUNTED EQUIPMENTS --- 3'-O,f p BATH COORDINATE ALL BLOCKING LOCATIONS �. r .. 01 DOOR TAG (SEE ACCOMPANYING SCHEDULE) AND QUANTITIES WITH CLIENT IN FIELD. WALL TAG (SEE WALL TYPES ON A-500 t FE 4 FOR DETAILS) NO. ISSUED DATE EXISTING E � WOMEN'S RAMP UP NC NURSE CALL BATH 11:12 LARSEN'S ARCHITECTURAL SERIES 2409-R4 FEC WITH FULL PANEL, CLEAR ACRYLIC UP 3R E ALUSEMI NUM RECESSED.WITH 3 " ROLLED EDGE 0 I T Stoi y Brook Medicine L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ` .�� I JaA EXISTING ENTRANCE WN 2 5 '_0211 7" MANCINI ARCHITECTURE mul CONSTRUCTION 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 I I I T- 631-979-0104 112'-44"+/- F: 631-979-3445 info@manciniarchitecture.com I 9'-2" 9'-0" 7'-9 „ 7'-0" 6'-3" 10'-0" 10'-0" 10'-0" 9'-0" 5" 9'-0" 11'-3" 1.0 ED A /-E � CLEAN ROOMMA STATION � � E A D C� 112 110 `° EXAM EXAM EXp,J�J q OFFICE/MGR • EXAM B B A A A A 109 107 A 101 WAITING STORAGE 1 os i I - I 103 100 I t A 113 SC IL ROOM I 112A in ( o� N ' CONSULT - ' D D 114 D (O D D D w - - — : D D ® -- -- ; 02 q 12 _ 1 30 03 I I 07 06 4,_0,> I C I I A D EXIT D D A I A A 01 This dra•:,'ng has been prepared for the 13 a I 14 1 I � indicated project and is an instrument of I.T. in in service copyrichted by P<1ancini Archite]cturn 115 4'-2" 2'-0" 2'-6" 8'(D 0 -3" Bl 8'-0" 11'-0" 1 9'-0" 9'-0" 5'-7" 2'-6" 1'-1" 5'-10" 1'-0" 5" 6'-7" G '1'-6" { PLLC. TI:s 1wing may not be copied or Ln ,, ' C` i , ',�. IVC D 'i/„ ', ,,., / „// ,', ,; i,`, (D8 ,', / / ,i,, ,J j ,,,,, .,� ,/,, ,. „ ,, _ ' us•-.d, In V.,S-lo!Fi or Irl part, lir ally p^rt}^ 4^.'ItlioLlt D D 'n ' j the er.pressed ^:ritten cons'^nt of Pl^nncini A A i I I 1 0 —— • —— —— • 05 CO -N 6'-0" 1 P,rc{1Eif Ctl:re PLLC. Infringements or anV (Jgp • of tills dravvina for an other purposes w;1! be A — J 04 I — I Y p r ' PHYSICIANS prosecuted to the ful! extend of criminal hrr✓ OFFICE MA STATION I I B1 e1 I SOFFIT I G 117 ; 116 I I MED ROOM I BATHROOM 6'-0" 11'-8" 8'-8" I 2' 2" El 22 `° 111 A EXAM MA STATION J A C ABOVE E + KEY PLAN i F EXAM OBGYN 105 104 _ ( RECEPTION I I �, M _ i E A - -- - ------- Q, J - STAFF --- ; - - - - - - / - -- o - --- - - r..^.... -- - - ------ -- --- ---- - - - - — - — — - - — -- ---- -- ------ - - — i o o --I ; LOCKERS 1 'Co { EXAM I I POWER PROVIDED A I 108 FOR EXTERIOR I o g I I SIGNAGE. ALL { El D I I B I JANITOR I ( I SIGNAGE PLANS AND 16 ,r 4'-3" I I D 124 D (D4 I 4'-8" 5'-0" 5'-7" REQUIREMENTS TO 22 BE DONE BY 777 7 20 //. — „ / ; //;' SIGNAGE COMPANY 2' 0„ A C A A A A G D EXIT o D 1 b 29 0 15 ' L BREAK ROOM q A j A A A 118 PROJECT 2'-s" 121 (D3 • 25 26 ® 27 28 • � STONYBROOK w 73 - " 18 (D9 I - - - ; - - - - - - - -- - MEDICINE ' PHIL BOTOMY I e1 _ _ A CRE LAB I I 10095 MAIN ROAD 121 A i �n MATTITUCK, NY 11952 E _ I I PICKUP I o ! ; WAITING E 120 3 I PASS q EXAM �o01 c° • EXAM �D 500 TH R U � 130 EXAM A j DRAWING TITLE o I o 119 ° o gl F EXAM OBGYN A I Ll o I RAMP UP UP 3R BATHROOM i 125 EXAM 129 PROPOSED FLOOR 1:12 123 EXAM A j ®I PLAN I 127 3R E] I I E A 00 I i E I E NCO E E / Q - - ""` ' ' _ IL SCALE SCALE AS SHOWN DRAWN BY ML I , - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ! - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ( DRAWN FOR -- CHECKED BY MM 25'-10j" 10'-0" 1'-3" 3'-9" 10'-5" 5'-10" 10'-6" 1 9'-0" 5' 9'-0" 5' 9'-0" 5' 10'-6" 14'-11" ( _ y —_ �. _ _ PROJECT# - DATE 3/9/2020 124'-10"+/— I SHEET NO. I , A- 1 00 132'-1"+/- PROPOSED FLOOR PLAN 8 /28 /20 ---- SHEET OF NO. REVISIONS DATE BLOCKING SCHEDULE WALL TYPE LEGEND REV. AS PER TOWN 8/12/20 PLYWOOD BLOCKING AT: 1 ALL CABINETS (E) EXISTING WALL TO REMAIN O � 2. TELEVISION NEW WALL (SEE TAG FOR TYPE) 0 0 o3. BATHROOM ACCESSORIESa,.. EXISTING 4. GRAB BARS DRAWING LEGEND BATH 5. WALL MOUNTED EQUIPMENT COORDINATE ALL BLOCKING LOCATIONS ir MULTI DIRECTION ELEVATION TAG (SEE NUMBERS FOR PAGE REFERENCE & t AND QUANTITIES WITH CLIENT IN FIELD. �? DRAWING NUMBER) NO. ISSUED DATE DIRECTIONAL ELEVATION TAG (SEE NUMBER FOR PAGE REFERENCE & 1 80% COMPLETION SET 4/16/20 EXISTING RAMP UP DRAWING NUMBER) 2 95% COMPLETION SET 5/14/20 H 3 COMPLETED CONST. SET 5/22/20 BATH 1:12 NC NURSE CALL 4 COMPLETED CONST. SET 6/4/20 _VP 3R SEMI—RECESSED FIRE EXTINGUISHER CABINET 5 COMPLETED CONST. SET 6/12/20 M. I I FEC 6 ISSUED FOR PERMIT 7/7/20 F-7-1 I L r HATCH REPRESENTS MILLWORK (SEE ACCOMPANYING TAG FOR MORE DETAILS) Stonv Brook Med icine - - A L - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING ENTRANCE - - - - - - — 2 ANCIN 1 1 /4"y=1 P—Oly ARCHITECTURE M U I CONSTRUCTION 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 T.- 631-979-0104 F: 631-979-3445 info@manciniarchitecture.com LLLLJ 72 AFF /1D a / a TV 7'-9j" MA STATION LEAN ROOM DITE] I I El ' 112 _ Jlu r3 EXAM OFFICE/MGR (�3 3 EXAM :� 0) 106 103 8 V4007 107 EXAM 400 EXAM WAITING Ejow9a I 400 STORAGE (0 4 400 I0-01t 4'-0" 4'-0" 4'-0" 01 01 10 SOIL M J lo i 2A 0 0 0 CONSULT z�/ EJ IJ -Cj -1 04 04 77T 7�77 _ I 77 This clravving has been prepared for the IFEC I EXIT indicated project and is an inst'runient of I.T. 2'-0" snervice copyrighted by r;lanclni Archifr-cture 115 ay not b(--, copied or L Li P'LL-C. This dra,,v�� g ri� used, in \�.,hole or in part, by any p-'rty without the eypres-,ed written consent of l,11incini 2'-0" 2'-0" 2'-0" 1 2" 0 Arch,teCtUre rLL-C. Infringemrnts or any Ll'zr' C oil this d!awing for any other purposes will be 2 0 S 2'—0 0 0 0 —p f L PHYSICIAN '04 _N J, 7 A-401 _N1 - 1 6 5 2'—q, 7------- KEY PLAN 4'-0" 'r, t 4'-0" 4'-0" o"01 OFFICE MA STATION M 3 O� I A& MA STATION RECEPT") 7) MED ROOM FJ -'o 1:1 L0 6 EXAM 2 O BATHROOM 1 ns F102 EXAM EXAM OBGYN 00 00, A401 I /vu 3 Ejk6:j Fi108 2 A:-40>0 1 C2 < -0 _DF 1- --STAFF —�' "I� X \,A400 9 4 WLOCKERS 2'-0 7' LIJ v JANITOR DI v P 1724 0 ' un F loll FTTT-1 C14 I r //7777777/7 777/7777777777 0 EXIT O I X PROJECT BREAK ROOM 2'—Ool STONYBROOK z MEDICINE -0 0 0 10095 MAIN ROAD 0 5� I I — — —U_ PHLEBOTOMY — MATTITUCK, NY 11952 C14 C-4 C-4 0 CARE LAB 01 ol 0.' DRAWING TITLE WAITING 4$-0" 4'-0" 4P-011 4'-0" El D A-401 /� PICKUP EXAM z 3 3 EXAM EXAM EXAM 3 PASS CE]o / ' 400 129 uEXAM 01 1177 0 E119 400 ► NITURE 0 EXAM OBGYN v EQUIPMENT PLAN 1:12 1 UP 3R BATHROOM ILI 1 1 127 1 L128 PROPOSED Li 2'-0", L'7!�)6 (0 THRU 7 2'-0" < RAMP UP Co 0 0 0 SCALE SCALE AS SHOWN D1 /111 1 0 V, J D ® aa . DRAWN BY T DRAWN FOR CHECKED BY MM — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — PROJECT# — — — — — — — — — — — — — — — — — — — — — — — — — — — — - — — — — — —— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — DATE 3/9/2020 SHEET NO. A- 1 01 PROPOSED FURNITURE PLAN 1/4"=1 I-0)1 L M 3 8 /27 /20 ---- SHEET OF NO. REVISIONS DATE fie it 1A GENERAL CONDITIONS 1. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE PROVISIONS OF THE NEW YORK - -',�,."+��''�/ �R ALL PLUM31NG WAS V ' lLr, D N tl &WATER,L1,"F NE! MUNICIPALITY. I ON t L� R% \k!� %nj h 1H �� l E STATE ( DINGREOUEREMENTSUSPECIFIED ZONINGN THE CODESSHOALLHBELAOCAL DHEREDVTONING AS (FOCAL�� A P ��061 E USE �t_A"�' `-UL T TING'{' �FOHE: GO\ � D AS NOTED FOR p ,/�/ FOR OR SHOWN ON THE DRAWINGS. ANY REQUIREMENTS SET FORTH ON THE DRAWING MORE DATE: g p # `i"-S��b YV��r ` CEt`" 1 IF�C� . - STRINGENT THAN CODE ARE TO BE FOLLOWED AND NOT MODIFIED WITHOUT THE ARCHITECT'S PERMISSION. WORKMANSHIP SHALL CONFORM TO THE BEST ACCEPTABLE STANDARDS FOR THE FEE: ��6 gY; OF CCCiJPAN(,'yA OAU""'h6 TRADES INVOLVED. NOTIFY BUILDING DEPARTMENT AT 2. ARCHITECTURAL SERVICES FOR THIS PROJECT ARE LIMITED TO THE PREPARATION OF THESE 765-1802 8 AM TO 4 PM FOR THE «� ^ PLANS (GENERAL CONSTRUCTION PLANS) CONFORMING WITH THE BUILDING CODE FOLLOWING INSPECTIONS: ELECTRICAL REQ?`. _; ,`,; BEFO.r;irl REQUIREMENTS. THE ARCHITECT IS AVAILABLE TO THE OWNER OR CONTRACTOR FOR 1. FOUNDATION - TWO RRQUIREDE Ar ^ INSPECTION CONSULTATION REGARDING THE INTENT OF THESE PLANS. ANY DEVIATION FROM THE PLANS FOR POURED CON-_RETREQUIREDOP'Eki`W`.� M AmTom"ImIENcl� UCEN'&' NY 11952 SHALL BE REPORTED TO THE ARCHITECT, IN WRITING, PRIOR TO COMMENCEMENT OF THE 2. ROUGH - FRAMING & PLUMEIN'G ♦ ® (� '� NO. ISSUED DATE WORK. 3. INSULATION V• � 3. ALL WORK SHALL BE EXECUTED IN SUCH A MANNER AS TO PROTECT THE SAFETY OF 4. FINAL - CONSTRUCTION MUST (� ♦ 1 80% COMPLETION SET 4/16/20 WORKERS AND THE: PUBLIC. BARRIERS AND OTHER PRECAUTIONARY MEASURES SHALL BE BE COMPLETE FOR C.O. f� ♦ o SITE DATA: 2 95% COMPLETION SET 5/14/20 ERECTED IN ACCORDANCE WITH THE AUTHORITIES HAVING JURISDICTION OR AS REQUIRED FOR ALL CONSTRUCTION SHALL MEET THE PLUr!3ERCERTIFICATION >000000 SAFETY DURING THE ENTIRE CONSTRUCTION OPERATION. REQUIREMENTS OF THE CODES OF NEW ON LEAD CONTENT BEFORE `V TAX MAP NO.: 1000-142-01 -26 3 COMPLETED CONST. SET 5/22/20 4. CONTRACTOR SHALL VERIFY ALL CONDITIONS COVERING OR AFFECTING THE STRUCTURAL YORK STATE. NOT RESPONSIBLE FOR CERTIFICA TE OF OCCUPA NOY / / ` ZONING: 4 COMPLETED CONST. SET 6/4/20 WORK, OBTAIN ALL DIMENSIONS TO INSURE PROPER STRENGTH, FIT AND LOCATION OF DESIGN OR CONSTRUCTION ERRORS. O GENERAL BUSINESS STRUCTURAL WORK;; AND REPORT TO THE ARCHITECT ANY AND ALL CONDITIONS WHICH MAY SOLDER USED IN WATER SITE AREA: 381,150 SQ. FT. (8.75 ACRES) 5 COMPLETED CONST. SET 6/12/20 INTERFERE WITH OFZ AFFECT PROPER EXECUTION AND COMPLETION OF THE NEW WORK. THE SUPPL Y S YS TEM CA NNO T ♦ ♦ O BUILDING AREA: 17,000 SQ. FT. 6 ISSUED FOR PERMIT 7/7/20 ARCHITECT IS TO BE NOTIFIED OF ANY AND ALL CHANGES. EXCEED 2/10 OF 1%LEAD, c� -10 5. THIS BUILDING SHALL CONFORM TO THE AMERICAN NATIONAL STANDARD FOR BUILDINGS, AND 0, 'o_ ��-- FACILITIES; PROVIDING ACCESSIBILITY AND USABILITY FOR PHYSICALLY HANDICAPPED COMPLY WITH ALL CODES OF ♦ 0" �,°�' PEOPLE, ANSI A117.1-2009. ALL COMPONENTS OF THIS BUILDING, WHETHER EXPLICITLY / ♦ PROJECT INFORMATION: STATED OR NOT, SHALL BE BARRIER FREE DESIGNS AS REQUIRED FOR PHYSICAL NEW YORK STATE & TOWN CODES •o- Stony Brook Medicine HANDICAPPED ACCESSIBILITY. AS REQUIRED AND CONDITIONS OF ♦ / 1-110 , 6. CONTRACTOR SHALT_ REPAIR ALL DAMAGED AND DISTURBED SURFACES AND AREAS TO THEIR / 0 - h6ti INTERIOR ALTERATION TO 3 EXISTING SUITES. ORIGINAL CONDITION, RESULTING FROM CONSTRUCTION, IN EXISTING AREAS. / 6. TOTAL WORK AREA: 4980 SQ.FT. s Tni���i Ai n���i����oDARD °� � 7. CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY AND/OR PERMANENT SUPPORT, S �� �,�'�,�1 `n /� BRACING, SHORING, ETC., AS REQUIRED FOR THE SAFE INSTALLATION OF NEW CONSTRUCTION. S ; 19L9111S.TEES 11 ♦ / 8. CONTRACTOR TO ALIGN ALL NEW CONSTRUCTION WITH EXISTING WALLS AND ROOF LINES AS N\/ � O / 0� `J�+ `j �/��'a-�� ( s n���/ heajs MANCINI INDICATED. PATCH EXISTING SURFACES AS REQUIRED TO A SMOOTH FINISH WITH ADJACENT / / 6 2 �� V NEW CONSTRUCTION. o �� / p, 9. WORK WHICH REQUIRES PATCHING SHALL BE DONE WITH THE SAME MATERIALS AND IN THE n- �, p m v,3- COI�Y� ' W� NfllA' ref flit-effleO SM ARCHITECTURE 0111 SAME MANNER AS ADJOINING WORK. ALL DUE PRECAUTIONS SHALL BE TAKEN TO INSURE �c / 6' CONSTRUCTION BONDING BETWEEN OLD AND NEW WORK. JOINING BETWEEN OLD AND NEW WORK SHALL BEA �� ♦ / �' S0 ` SMOOTH CONTINUOUS FINISH TO ELIMINATE ANY VISUAL EVIDENCE OF JOINING. / ��� -Rre, IN claw rlamush Country Middle Count 10. CONTRACTOR SHALL PRESENT THE BUILDING TO THE OWNER FOR ACCEPTANCE CLEAN AND Smithtown, 7 Suite 314 ♦ �� � Smithtown, NY 11787 READY FOR OCCUPANCY. ALL DEBRIS IS TO BE CONTAINED IN DUMPSTERS OR TRUCKS AND ♦ 19 �ej T: 631-979-0104 CARTED AWAY FROM THE SITE. CONTRACTOR IS RESPONSIBLE FOR LEGAL DISPOSAL OF ALL �, �o S�bm/ l 6nCe.- StIeC F: 631-979-3445 ITEMS TAKEN FROM THE SITE. r, "' �O info@manciniarchitecture.com 11. RENTAL CHARGES, SAFETY, PROTECTION AND MAINTENANCE OF RENTED EQUIPMENT SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 12. CONSTRUCTION SAFETY, INCLUDING CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, COMPLIANCE WITH STATE AND FEDERAL REGULATIONS REGARDING SAFETY SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 13. ALL MATERIALS USED TO COMPLETE RENOVATION WORK ARE TO BE NEW. SALVAGED MATERIALS MAY BE: USED UNDER CERTAIN CONDITIONS SUBJECT TO ARCHITECT OR OWNER'S X26 �.r �' `so p�EO AR } APPROVAL. PROJECT LOCATION 515 '° ,5�� p0 Gctii� 14. ALL DEMOLITION WORK TO BE RESTRICTED TO AREAS SHOWN ON THE PLAN. CARE IS TO BE o- a �G� F TAKEN NOT TO DISTURB ADJACENT WALLS, CEILING OR STRUCTURE TO REMAIN. 6�,2 ¢ C) 15. ANY STRUCTURAL MEMBERS ENCOUNTERED DURING DEMOLITION ARE TO REMAIN UNLESS DIRECTED TO BE REMOVED BY THE ARCHITECT. PROVIDE TEMPORARY SHORING OR SUPPORTS AS REQUIRED. O tk x 16. CONTRACTOR SHALL FURNISH THE USUAL TRADE GUARANTEES, GUARANTEEING ALL N --- - ��'9 0381-0 OQ� MATERIALS AND WORKMANSHIP AGAINST ORIGINAL DEFECTS AND AGAINST INJURY FROM rr� D5? y ,� PROPER, USUAL WEAR, WHEN USED FOR THE PURPOSE INTENDED FOR A PERIOD OF ONE ^ , �_ 1 �` �� Q� OF NE`N �6. r'O lJ YEAR AFTER COMPLETION OF THE WORK OF THIS CONTRACT. THE PERIOD OF ONE YEAR12.4 BEGINS ON THE DATE OF FINAL PAYMENT. DEFECTS APPEARING DURING THAT YEAR SHALL BE MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE. `lJ 17. TEMPORARY STORAGE AND PROTECTION OF TOOLS, EQUIPMENT, AND MATERIALS SHALL BE THE CONTRACTORS RESPONSIBILITY. 18. PERFORM DEMOLITION, ALTERATION AND REMODELING WORK INDICATED TO PRODUCE FINISHED This drawing has been prepared for the RESULTS SHOWN AND DESCRIBED ON THE DRAWINGS. THE CONTRACTOR SHALL COORDINATE indicated project and is an instrument of ALL REMODELING WORK AND SHALL BE RESPONSIBLE FOR DIVISION OF WORK BETWEEN THE service copyrighted by Mancini Architecture VARIOUS SUBCONTRACTORS. DRAWING LIST PLLC. This drawingmay not be copied/ used, in whole or in part, by any party without -� � 19. UNFINISHED SURFACES CREATED BY REMOVAL OF EXISTING MATERIALS AND SURFACES j / the expressed written consent of Mancini DAMAGED OR DISTURBED BY REMODELING WORK SHALL BE PATCHED WITH NEW MATERIALS AND FINISHED TO MATCH THE EXISTING WORK. �,A ^'I,/ ARCHITECTURAL Architecture PLLC. Infringements or any use Q of this drawing for any other purposes will be GENERAL NOTES:_ T-100 TITLE SHEET AND BUILDING INFORMATIONprosecuted to the full extend of criminal law 1/1 / / / <D ---- --- TRACTOR IS RESPONSIBLE FOR SCHEDULING ALL INSPECTIONS, APPROVALS, / T-200 STANDARD ACCESSIBLE CODES & DETAILS 1. THE CON '` CERTIFICATES, CERTIFICATES OF OCCUPANCY OR COMPLETION, U.L. APPROVALS, AND ANY �� / KEY PLAN OTHER MUNICIPAL REQUIREMENTS. / / A-001 CODE SHEET & EGRESS PLAN 2. ALL DISCREPANCIES ATTENT ON REGARDING OF THETHE ENGINEER IMMEDIATELYGS ARE TO BE BEFORE PROGRESSINGIMMEDIATELY FURTHER v / --� BROUGHT TO THE G A\ . A-010 DEMOLITION FLOOR PLAN WITH ANY AND ALL. WORK. 3. THE DRAWING IS NOT TO BE SCALED AND ALL DIMENSIONS ARE TO BE VERIFIED BY THE // CONTRACTOR. / PQ A-100 PROPOSED FLOOR PLAN nn A-101 PROPOSED FURNITURE CONTRACTOR PERFORMANCE: / & EQUIPMENT PLAN / PA-101 PROPOSED REFLECTED CEILING PLAN 1. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS OF CONSTRUCTION. NO , _\ \ / DETAIL INCLUDED HEREIN IS MEANT TO SUBSTITUTE FOR THE CONTRACTOR'S KNOWLEDGE AND Z - EXPERIENCE OF THE PROPER PREPARATION, TOOLING, SCHEDULING, PROCEDURES, LIMITATIONS, o A-300 PROPOSED FINISH PLAN AND REQUIREMENTS OF THE MATERIALS TO BE INSTALLED. / /CO. ��o. / -- 2. THE CONTRACTOR AND SUB-CONTRATOR(S), ARE ALL REQUIRED TO PERFORM A PRE-BID SITE lJ / p /�DC A-400 INTERIOR ELEVATIONS INSPECTION ALONG WITH A COMPLETE REVIEW OF THE DRAWINGS AND SPECIFICATIONS OF THE - - �9. / PROJECT PROJECT. �S A-401 INTERIOR ELEVATIONS 3. THE CONTRACTOR SHALL INDICATE ALL EXCEPTIONS TO THE DESIGN IN HIS BID DOCUMENT. `` / ,* _ STONY BROOK NO CONTRACTOR EXCEPTIONS SHALL BE ACCEPTED BY THE OWNER OR HIS DESIGNEE WITHOUT FULL WRITTEN APPROVAL OF THE ARCHITECT AND ENGINEER. /. �1 A-410 MILLWORK SECTIONS MEDICAL 4. THE CONTRACTOR'S WORKMANSHIP IS TO BE OF THE HIGHEST GENERALLY ACCEPTED 5t`b RD - 10095 MAIN ROAD STANDARD IN THEE INDUSTRY AND LACK OF PERFORMANCE IN ANY NATURE BY THE A-500 CONSTRUCTION DETAILS MATTITUCK, NY 11952 CONTRACTOR WILL BE DEEMED A VIOLATION OF HIS CONTRACT. 5. THE CONTRACTOR SHALL PROVIDE A FULL WARRANTY FOR ALL MATERIALS AND WORKMANSHIP A-600 SCHEDULES PROVIDED. THE WARRANTY LENGTH SHALL BE AS SO NEGOTIATED BETWEEN THE OWNER AND N DRAWING TITLE CONTRACTOR. PLOT PLAN MECHANICAL - PLOT PLAN & FINISH NOTES M-101 MECHANICAL PLAN 1 -50 PROJECT INFO. GYPSUM BOARD M-201 MECHANICAL DETAILS 1. GYPSUM BOARD SHALL BE 5/8" THROUGHOUT UNLESS NOTED OTHERWISE ON THE DRAWINGS M-401 MECHANICAL SCHEDULES OR SPECIFICATIONS. FASTEN AT 8" O.C. FOR WALL APPLICATIONS. METAL CORNER BEADS M-501 MECHANICAL SPECIFICATIONS SCALE SCALE AS SHOWN SHALL BE USED AT ALL OUTSIDE CORNERS. ALL JOINTS SHALL BE TAPED, SPACKLED AND SANDED .SMOOTH, POLISHED AND READY FOR PAINTING. DRAWN BY ML 2. GYPSUM BOARD IN RATED WALLS INDICATED ON THE PLANS SHALL BE 5/8" TYPE Y' E=101 ELECTRICAL POWER PLAN DRAWN FOR -- GYPSUM BOARD AS REQUIRED BY CODE. E-102 ELECTRICAL LIGHTING PLAN CHECKED BY MM 3. GYPSUM BOARD SHALL BE AS MANUFACTURED BY GEORGIA PACIFIC, OR APPROVED EQUAL, AND SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH MANUFACTURES E-401 ELECTRICAL PANEL SCHEDULE & DETAIL'S PROJECT# -- RECOMMENDATIONS. 4. IN WET AREAS AND UNDER CERAMIC TILE WALL FINISHES, USE 7/16" WONDER BOARD E-501 ELECTRICAL SPECIFICATIONS DATE 3/9/2020 INSTALLED IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. P-101 PLUMBING PLAN SHEET NO. PAINTING P-201 PLUMBING DETAILS 1. GYPSUM BOARD WALLS SHALL RECEIVE ONE COAT OF PRIMER SEALER AND A MINIMUM OF T- 1 00 P-301 PLUMBING RISERDIAGRAMS TWO COATS OF LATEX WALL PAINT UNLESS NOTED ON THE DRAWINGS. APPEARANCE v RATHER THAN NUMBER OF COATS DETERMINE ACCEPTANCE OF FINISH SURFACE. PAINT SHALL P-501 PLUMBING SPECIFICATIONS BE BY BENJAMIN MOORE OR APPROVED EQUAL. SEE CORPORATE DESIGN MANUAL FOR -- --- COLOR SELECTION AND LOCATION N ---- SHEET OF TYPICAL DEVICE LOCATION & HEIGHT LEGEND STANDARD ADA ICC/ANSI A117.1 504 STAIRWAYS NO. REVISIONS DATE FIGURE 504.5 STAIR NOSINGS E0. E0. RADIUM AX 1i" MAX 1i" MAX 1'-21" MIN _ Z FIRE ALARM DEVICE CURVED BEVELED X LINE OF FINISHED CEILING CLOCK TYP. STROBE. STROBE HORN OR SPEAKER FlRE E I T EXIT SIGN LOCATION CCC���� OUTLET N OPTION 1:WALL MOUNTED ADJACENT TO ALARM OPTION 1:CEILING MOUNT (TYPICAL (A)VERTICAL RISER (B) CURVED NOSING (C)BEVELED RISER (D)ANGLED RISER FIGURE 504.2 TREADS AND VI DOOR 6'-8" AFF (TYPICAL DECE UNLESS OTHERWISE NOTED) RISERS FOR ACCESSIBLE � UNLESS OTHERWISE NOTED) OPTION 2:WALL MOUNTED 7'-10" AFF STAIRWAYS TV Fol OUTLET OPTION 2:CENTERLINE OF WALL OR I o 8` MEASURED TO TOP OF SIGN _ COLUMN IN OPEN AREAS OR ® �IYPICAL FROM CORNER OF WALL (SEE o 0 O DATA/COMMUNICATIONOR OJACK I SHELF 2`MIN BELOW) o o PLUMBING ELEMENTS: TRANSFER TYPE SHOWER COMPARTMENT FIRE HOSE CABINET z OUTLET OR COMBINATION I Ir OUTLINE OF WALL" w w TYPICAL DOOR FRAME NO. ISSUED DATE z Q z DATA/COMMUNICATION JACK w Y z ® HOOK = 1 80% COMPLETION SET 4/16/20 a a rr' z w IX F w 0 a a � 1'-3�" 11�" MIN. 36" I,,o 8_ <� a�a w o Y a w N THERMOSTAT DEVICE 18` x 2 95! COMPLETION SET 5/14/20 W a 0 0" z 0 0 U F- U o SIDE WALL 22"-23" a a w FOR ADA USE MICROWAVE OPTION 1:WALL MOUNTED ADJACENT TO z �a w� O a a k'-� o T ,T 3 COMPLETED CONST. SET 5/22/20 a a o z� a a WILL BE RELOCATED TO DOOR 48" AFF (TYPICAL UNLESS 7" z 3 o v S v 2"MIN 2"MIN COUNTERTOP. OTHERWISE NOTED) ADA COAT SEAT o a .. OPTION 2 CENTERLINE OF WALL OR HOOK WALL coNTROLo SEAT 4 COMPLETED CONST. SET 6/4/20 w ¢ U * * Y WALL M WALL 5 COMPLETED CONST. SET 6/12/20 w of ® ® mo COLUMN IN OPEN AREAS OR 8` 7 w o in 2"MIN 2"MIN ® o ® z o FROM CORNER OF WALL (SEE a 6 ISSUED FOR PERMIT 7/7/20 *mac I BELOW) e o Z x o i� I I ro co 2�` 1 ® ® TYPICAL BACK SPLASH r� n 6400- - 15"-16" M `O m w ® ® ® p TYPICAL BUILT-IN OUTLET OR COMBINAl10N OUTLINE OF WALL 2`MIN. x a o 4 1 z z I I DATA COMMUNICATION JACK = . 48"MIN to a w WORK SURFACE / z a a p a o WITHOUT GROMMETS a o m o m O Q W -J z x Q z SINGLE OR F p z � tO r X (L ¢ TYPICAL BUILT-IN c� I I 11 ` MIN. 11�" MIN. g X GANGED SWATCH o N o a a ` tifl17y Brook OC�IC]1�G WORK SURFACE =p m a z o wO N wo v CONTROL LOCA710N L-SHAPED SHOWER SEAT i 0 1'-3J" (INCLUDING Y w w O F v WITHOUT GROMMETS rn I I o DIMMERS & U v O w=p w¢x COMPARTbtENT SIZE AND CLEARANCE o , do °1N SWATCH-MOTION wo Z w Z _ p I �a a 0 ®3 o a m `I �* COMBO. wap � a m¢vxi x a o 0 0 eroi Q N I '� I 0 ® ® FINISHED BASE -' w �`' o z a z a a I Q a zp wg LU 0c N I I a TYPICAL UNLESS FINISHED FLOOR z o a z MOUNTING HEIGHTS: TOILET ACCESSORIES WITH OPERABLE PARTS N , fX OTHERWISE NOTED w u� ao p`� M� I I C � Yy a0 M U U v MAN C I B ARCHITECTURE A C _ DISCRIP71ONS _ CONSTRUCTION �� A. TOILET SEAT COVER • mul_ B. PAPER DISPENSER/DISPOSAL x C. PAPER DISPENSER a ( E 222 Middle Country Rd, Suite 314 g- D. SOAP E. TOILETDISPENSER PAPER DISPENSER > g 1 Smithtown, NY 11787 T. 631-979-0104 STANDARD ADA AND ICC/ANSI A117.1 308 HANDRAILS STANDARD ADA AND ICC/ANSI A117.1 STANDARD ADA AND ICC/ANSI A117.1 STANDARD ADA AND ICC/ANSI A117.1 ELEVATION HEIGHTS: ACCESSORIES WITH OPERABLE PARTS ELEVATION HEIGHTS:MIRROR & COAT HOOK F 631-979-3445 306 KNEE & TOE CLEARANCE 303 CHANGES IN LEVEL 304 WHEELCHAIR TURNING SPACE NOTE: NOTE: info@manciniarchitecture.com *MOUNTED OVER AN OBSTRUCTION: Y = 40 IF LOCATED OVER A LAVATORY OR COUNTERTOP IF OBSTRUCTION DEPTH IS 20", THEN MAX Y= 35" IF NOT LOCATED OVER A MOUNTING HT ALLOWED IS 48" LAVATORY COUNTERTOP 308.2 FORWARD REACH. IF OBSTRUCTION DEPT IS 20"-25" MAX, 308.2.1 UNOBSTRUCTED. WHERE A FORWARD REACH IS X 5' MIN THEN MAX MOUNTING HT ALLOWED IS 44" UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 8" Q 5' MIN 48" MAXIMUM AND THE LOW FORWARD REACH SHALL a x¢ xa BE 15" MINIMUM ABOVE THE FLOOR OR GROUND. ;' Z (- ( ¢ 308.2.2 OBSTRUCTED HIGH REACH. WHERE A HIGH r , / ~� " I z /% FIGURE 303.2 VERTICAL CHANGES IN LEVEL /� �� I I STANDARD ADA AND ICC ANSI A117.1 505 HANDRAILSP�Dc�cti% M ao FORWARD REACH IS OVER AN OBSTRUCTION, THE ( 1 i�j Z CLEAR FLOOR OR GROUND SPACE SHALL EXTEND I ' J M BENEATH THE ELEMENT FOR A DISTANCE NOT LESS I L� 2 � THAN THE REQUIRED REACH DEPTH OVER THEN .. I L m OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE J °' •=1d / N -J 48" MAXIMUM WHERE THE REACH DEPTH IS 20" �=1N 1' MIN. S ti� _ 1 MIN M11 MIN t MAXIMUM. WHERE THE REACH DEPTH EXCEEDS 20`, 17" MIN - 10" MAX 10"-24" MAX 10" MAXE HIGH FORWARD REACH SHALL BE 44" MAXIMUM PERIMETER 11" 4" TO 61" (A)CIRCULAR x AND THE REACH DEPTH SHALL BE 24` MAXIMUM. (B)T-SHAPED X z zFIGURE 306.2 TOE CLEARANCE FIGURE 306.3 KNEE CLEARANCE FIGURE 303.3 BEVELED CHANGES IN LEVEL X �j 0381�� ��� EPTH FIGURE :f0 .3.2 FIGURE 308.3.1 308.3 SIDE REACH. FIGURE 304.3 NOTE: OBSTRUCTED HIGH SIDE REACH UNOBSTRUCTED SIDE REACH SIZE OF WHEELCHAIR TURNING SPACE DX-TREAD r' OF NE`N y 308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO (A)CIRCULAR B)NON-CIRCULAR (C)NON-CIRCULAR AN ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, FIGURE 505.10.3 THE HIGH SIDE REACH SHALL BE 48 MAXIMUM AND FIGURE 505.7 HANDRAIL CROSS SECTION THE LOW SIDE REACH SHALL BE 15" MINIMUM ABOVE TOP HANDRAIL EXTENSIONS DR AIL STAIRS FIGURE 505.10.2 BOTTOM HANDRAIL THE FLOOR OR GROUND. EXCEPTION: EXISTING 20" MAX ELEMENTS SHALL BE PERMITTED AT 54" MAXIMUM EXTENSIONS AT STAIRS 20"-25" MAX ABOVE THE FLOOR OR GROUND. STANDARD ADA AND ICC/ANSI 117.1 404.2.3 STANDARD ADA AND ICC/ANSI STANDARD ADA AND ICC/ANSI A117.1 308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR CLEAR WIDTH OF DOORWAYS 117.1 305 CLEAR GROUND SPACE 303 CHANGES IN LEVEL 12" MIN 12" MIN 1J7MIN. This drawing has been prepared for the FLOOR OR GROUND SPACE ALLOWS A PARALLEL _ �I M indicated project and is an instrument of APPROACH N AN OBJECT AND THE HIGH SIDE REACH ,`*� .� S2NICe copyrighted by Mancini Architecture O OVER AN OBSTRUCTION. THE HEIGHT E THE M PLLC. This drawing may not be copied or OBSTRUCTION SHALL BE 34" MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24" MAXIMUM. THE 48"MIN X ¢ HIGH SIDE REACH SHALL BE 48" MAXIMUM FOR A 32" MIN -_ AT 6j MREACH DEPTH OF 10` MAXIMUM. WHERE THE REACH used, in whole or in art, b an y x p y y part without -1 Q (A)STAIRS (B)RAMPS (A)CIRCULAR the expressed written consent of Mancini to DEPTH EXCEEDS 10", THE HIGH SIDE REACH SHALL BE 32" MIN 32" MIN I p z .r 46" MAXIMUM FOR A REACH DEPTH OF 24" MAXIMUM. o,� 'I` ) I FIGURE 505.10.1_ TOP AND BOTTOM HANDRNL FIGURE 505.4 HANDRAIL HEIGHT FIGURE 505.5 Architecture PLLC. Infringements or any use ® O I a EXTENSIONS AT RAMS HANDRAIL CLEARANCE of this drawing for any other purposes will be _ B) SLIDING DOOR C) FOLDING DOOR I- ) I to prosecuted to the full extend of criminal law A) HINGED DOOR -__-_J FIGURE 302.2 FIGURE 308.2.2 FlGURE 308.2.1 CARPET ON FLOOR OR GROUND SURFACE OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED FORWARD REACH STANDARD ADA AND ICC/ANSI A117.1 404.2.4.2 MANEUVERING KEY PLAN CLEARANCE AT SLIDING AND FOLDING DOORS STANDARD ADA AND ICC/ANSI A117.1 404.2.4.2 MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS PLUMBING ELEMENTS: 'WATER CLOSET AND LAVATORY --- 1 � FRONT APPROACH - SWINGING DOOR HINGE SIDE APPROACH - SWINGING DOOR LATCH SIDE APPROACH - SWINGING DOOR I o -- NOTE: X=36" MIN IF Y=60" Y=54" MIN IF DOOR HAS CLOSER m _ 'a -10" ( 1 I PULL SIDE I X=42" MIN IF Y=54"_ X 36"MIN 24"MIN I �(� PULL SIDE I PULL SIDE 60" MIN 48"MIN A) FRONT APPROACH B) POCKET OR HINGE APPROACH C) STOP OR LATCH APPROACH 12"MIN 54"MIN v 18" _z xC11 4> ---- 39"-41" 0 M N I 24"MIt� X 00 \r 42"MIN 12"MAX - - z z 36"MIN I M1 r I I 124 MIN 1 r //�� N I I 42"MIN TWO HINGED DOORS IN SERIES TWO HINGED DOORS IN SERIES PROJECT N _I (0 Do _ 12"MIN 24"MIN I "l!" PUSH SIDE 54" M 0) Ln N-��I� L PUSH SIDE ---�- NOTE: Y=48" MIN IF DOOR PUSH SIDE STONY BROOK HAS BOTH A CLOSERY=48" MEDICAL �t 16 t8 (0 AND LATCH MIN IF DOOR HAS CLOSER "- 7 17 SIDE APPROACH - SWINGING DOOR E2°i 10095 MAIN ROAD 01 60 "MIN01 P' MATTITUCK, NY 11952 MANUAL SWINGING DOORS: CLEARANCES DRINKING FOUNTAINS DRAWING TITLE TOILET PLAN: LOCATION AND CLEARANCES TOILET ELEVATION HEIGHTS: SEAT GRAB BARS, & DISPENSER 602.1 GENERAL DRINKING FOUNTAINS SHALL COMPLY WITH 307 AND 602. V TA N DA R D DETAILS NOTE: 602.2 CLEAR FLOOR SPACE.UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING PULL SIDE PULL SIDE Y = 54" IF DOOR WITH 305 POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT.KNEE AND TOE r-- -1 -------1 HAS CLOSER CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. NOTE: } EXCEPTION:A PARALLEL APPROACH COMPLYING WITH 305 SHALL BE PERMITTED AT UNITS FOR 1 CHILDREN'S USE WHERE THE SPOUT IS 30 INCHES(760 MM)MAXIMUM ABOVE THE FINISH FLOOR OR „ 0 18" MI I T Y a 54" I I GROUND AND IS 3 V2 INCHES(90 MM)MAXIMUM FROM THE FROM EDGE OF THE UNIT,INCLUDING A to 171t-25 I I I > THEN X = 42" BUMPERS. z -'� N. - I -- X IF Y = 60" I --24 MI 602.3 OPERABLE PARTS.OPERABLE PARTS SHALL COMPLY WITH 309. THEN X 36` 15'MIN. 15 MIN SCALE SCALE AS SHOWN= 00 602.4 SPOUT HEIGHT.SPOUT OUTLETS SHALL BE 36 INCHES(915 MM)MAXIMUM ABOVE THE FINISH Z X 3 2•MIN FLOOR OR GROUND. DRAWN BY ML CLEAR � Q X z 602.5 SPOUT LOCATION.THE SPOUT SHALL BE LOCATED 15 INCHES(380 MM)MINIMUM FROM THE DRAWN FOR Q Z VERTICAL SUPPORT AND 5 INCHES (125 MM) MAXIMUM FROM THE FRONT EDGE OF THE UNIT, FLOOR INCLUDING BUMPERS. SPACE o K fi2" IF DOOR HAS - - �ti_ o - CHECKED BY MM cl BOTH CLOSER N0�• _ � AND LATCH Y_�S" IF CLOSER FIGURE 602.6 DRINKING FOUNTAIN SPOUT LOCATION602.6 WATER FLOW,THE SPOUT SHALL PROJECT# » N '12` MIN NOTE* PROVIDED PROVIDE A FLOW OF WATER 4 INCHES(100 MM)HIGH MINIMUM AND SHALL BE LOCATED 5 INCHES (Jl 3 0 MIN �- Y = 48"IF DOOR ���((( L1 -- -'C-�I'� (125 MM)MAXIMUM FROM THE FRONT OF THE UNIT.THE ANGLE OF THE WATER STREAM SHALL BE } HAS BOTH MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE r -� I I 3/9/2020 11"M N "MAX I I I CLOSER & LATCH r LOCATED LESS THAN 3 INCHES(75 MM)OF THE FRONT OF THE UNIT,THE ANGLE OF THE WATER / 1 x~ �� DATE O STREAM SHALL BE 30 DEGREES MAXIMUM.WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES(75 I X 1 I I 22 MIN *IF BOTH CLOSER 4" MIN MM)AND 5 INCHES(125 MM)MAXIMUM FROM THE FRONT OF THE UNIT,THE ANGLE OF THE WATER - `' `'. - n& - SHEET NO. & LATCH PROVIDED I 2 STREAM SHALL BE 15 DEGREES MAXIMUM. - I N N ADVISORY 602.6 WATER FLOW.THE PURPOSE OF REQUIRING THE DRINKING FOUNTAIN SPOUT TO �ITll, a LAVATORY PLAN: CLEAR FLOOR SPACE LAVATORY ELEVATION: TOE & KNEE CLEARANCE `� PRODUCE A FLOW OF WATER 4 INCHES(100 MM)HIGH MINIMUM IS SOTHATACUPCAN BE INSERTED UNDER THE FLOW OF WATER TO PROVIDE A DRINK OF WATER FOR AN INDIVIDUAL WHO,BECAUSE 1 30'MIN. OF A DISABILITY,WOULD OTHERWISE BE INCAPABLE OF USING THE DRINKING FOUNTAIN. T-200 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS.SPOUT OUTLETS OF DRINKING FOUNTAINS A. SIDE VIEW BELEVATION VIEW FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 INCHES (1090 MM) B. MAXIMUM ABOVE THE FINISH FLOOR OR GROUND DRAWING BASED ON ELKAY ENHANCED EZH2O MODEL LZSTL8WSLP �. ---- SHEET OF NO. REVISIONS DATE 2020 EXISTING BUILDING CODE OF NEW YORK STATE BUILDING CODE/DATA CHAPTER 3 - COMPLIANCE METHOD THE FOLLOWING REVIEW IS IN ACCORDANCE WITH THE 'WORK AREA METHOD' AS PER EBC301.3.2 SCTM #: 1000-142-01-26 LOT AREA: 381,150 SQ.FT. (8.75 ACRES) ACCESSIBILITY REQUIREMENTS FOR EXISTING BUILDINGS SHALL COMPLY WITH THE 2009 EDITION OF ICC A117.1 T.O.S. ZONING: GB (GENERAL BUSINESS) CHAPTER 6 - CLASSIFICATION OF WORK OCCUPANCY CLASSIFICATION: B (BUSINESS) CONSTRUCTION TYPE: AS THE EXISTING BUILDING IS A GROUP B WITH A WORK AREA LESS THAN 50%, THEREFORE THE EBC ANALYSIS HAS BEEN PERFORMED AS AN SPRINKLER: SPRINKLERED ALTERATION-LEVEL 2 PER EBC605. THEREFORE, THE BUILDING WILL BE ANALYZED FOR COMPLIANCE WITH CHAPTERS 7 THROUGH 8. OCCUPANCY/EGRESS: EBC SUPPORTING INFORMATION OR SPACE CLASSIFICATION: FLOOR AREA SF/OCC OCCUPANTS CODE BUILDING ELEMENT CODE REQUIREMENT PROVIDED DOCUMENTATION GROUND FLOOR (BUSINESS): 4980 SF 100 GROSS 49.8 CITATION TOTAL: 50 OCC. CHAPTER 7 - ALTERATIONS LEVEL 1 NO. ISSUED DATE 701.3 FLOOD HAZARD AREAS N/A N/A THIS BUILDING IS NOT LOCATED WITHIN IN A BC 1017 TRAVEL DISTANCE: 1 80% COMPLETION SET 4/16/20 FEMA SPECIAL FLOOD HAZARD AREA. MAXIMUM:000. B W/ SPRINK. 300' W/ SPRINKLERS 2 95% COMPLETION SET 5/14/20 702 BUILDING ELEMENTS AND MATERIALS 702.1 INTERIOR FINISHES, FLOOR BC 804.4: INT. FLOOR WILL COMPLY SEE FINISH SCHEDULE ACTUAL MAX TRAVEL DISTANCE: 104' LONGEST DISTANCE 3 COMPLETED CONST. SET 5/22/20 THROUGH FINISH, AND TRIM FINISH SHALL HAVE 4 COMPLETED CONST. SET 6/4/20 702.3 A MIN CLASS II CRITICAL RADIANT BC 1006 NUMBER OF EXITS: 5 COMPLETED CONST. SET 6/12/20 FLUX RATING 703.1 FIRE PROTECTION REQUIRED - FIRE ALARM TO BE FILED UNDER SEPARATE NUMBER OF EXITS REQ'D: 2 EXITS PER BC TABLE 1006.3.1 6 ISSUED FOR PERMIT 7/7/20 PERMIT BY VENDERS NUMBER OF EXITS PROVIDED: 3 EXITS 704.1 MEANS OF EGRESS MAINTAIN THE LEVEL EGRESS PATHS ARE SEE DRAWING A-001 FOR EGRESS PLAN AND BC 1005.3.2 MINIMUM EXIT WIDTH: OF PROTECTION COMPLIANT WITH PROPOSED CALCULATIONS. PROVIDED USE/OCCUPANCY 50 OCC. X 0.20 IN. PER OCC. 10 IN. REQUIRED Stony B1'00k MCdICl13C 707.1 ENERGY CONSERVATION, NEW ENVELOPE AND N/A NEW WALL.IN EXISTING PATCHED WINDOW (2) EXIST. 72 IN. DOORS = 144 IN. MINIMUM REQUIREMENTS MECHANICAL OPENING TO CONFORM TO ECC. 1 EXIST. 36 IN. DOOR = 36 IN. EQUIPMENT SHALL ( ) CONFORM TO ECC TOTAL EXIT DOOR WIDTH PROV'D = 180 IN. CHAPTER 8 - ALTERATIONS LEVEL 2 BC 1005.5 DISTRIBUTION OF MIN WIDTH/CAPACITY: 802 BUILDING ELEMENTS AND MATERIALS 50% x 50 OCC. = 25 OCC. 802.4 INTERIOR FINISH CORRIDOR FINISH TO CORRIDORS CLASS C MIN TO BE - 25 OCC. x 0.20 IN PER OCC = 5 IN REQ'D MANCINI COMPLY W/ BC TABLE PROVIDED W/ LOSS OF 1 EXIT. (1) 36 IN. DOORS = 144 IN > 2.2 IN. REQ'D 803.11 INT. EXIT STAIRS: CLASS B TO BE ARCHITECTURE PROVIDED (EXISTING TO REMAIN) 803 FIRE PROTECTION PLUMBING FIXTURES: M U I CONSTRUCTION WATER CLOSETS: 803.2 AUTOMATIC SPRINKLERS REQUIRED WHERE >30 EXISTING BUILDING IS N/A REQUIRED: (B)1 PER 25 FOR FIRST 50, 1 PER 50 FOR REMAINDER 222 Middle Country Rd, Suite 314 OCCUPANTS. NON-SPRINKLERED. BUSINESS: (8)50/2= 25 OCC. = 1 MALE & 1 FEMALE REQ'D Smithtown, NY 11787 803.4 FIRE ALARM AND PER FIRE ALARM PER FIRE ALARM VENDER PER FIRE ALARM VENDER. FILED UNDER 2 MALE & 2 FEMALE PROVIDED T 631-979-0104 DETECTION VENDER SEPARATE PERMIT LAVATORIES: F: 631-979-3445 803.4.3 SMOKE ALARMS PER FIRE ALARM PER FIRE ALARM VENDER PER FIRE ALARM VENDER. FILED UNDER REQUIRED: (B)1 PER 40 FOR FIRST 80, 1 PER 80 FOR REMAINDER info@manciniarchitecture.com VENDER SEPARATE PERMIT BUSINESS: (8)50/2= 25 OCC. = 1 MALE & 1 FEMALE REQ'D 805 MEANS OF EGRESS 2 MALE & 2 FEMALE PROVIDED (EXIST) 805.3 NUMBER OF EXITS MINIMUM OF ONE EXIT 2 EXITS REFER TO THE EGRESS PLAN AND CALCULATIONS ON SHEETS A-001. 805.4.1 TWO EGRESS DOORWAYS OCCUPANT LOAD & WHERE APPLICABLE, WILL EXISTING BUILDING HAS 3 MEANS OF REQUIRED TRAVEL DISTANCE COMPLY EGRESS. >50 OCCUPANTS, OR EGRESS PLAN LEGENDs >75 FT TRAVEL ,�ERED ARc� DISTANCE ��5 \�.p0 G 2, yid 805.4.2 DOOR SWING >50 OCCUPANTS, WILL COMPLY SEE PLANS DOOR TO SWING IN s 'a DIRECTION OF TRAVEL 805.4.3 DOOR CLOSING EXIT DOORS SHALL BE SELF CLOSING DOORS EXISTING STAIR EXIT DOOR ARE SELF s s a e ® s TRAVEL DISTANCE SELF-CLOSING PROVIDED CLOSING ' FT �3�1?� 20 FQy 805.6 DEAD END CORRIDORS COMPLY W/ BC N/A N/A O 1020. MAX EXIT SIGNS OF NE`Ny _ 805.7 MEANS OF EGRESS ARTIFICIAL LIGHTING MEANS OF EGRESS ARE ALL MEANS OF EGRESS ARE EQUIPPED WITH LIGHTING REQUIRED EQUIPPED WITH ARTIFICIAL ARTIFICIAL LIGHTING AS PER IBC. SEE LIGHTING REFLECTED CEILING PLAN INTERIOR FINISH REQUIREMENTS (BC 803.11) 805.8 EXIT SIGNS EXIT SIGNS REQUIRED ILLUMINATED EXIT SIGNS REFER TO THE EGRESS PLAN ON DRAWING Wall & Ceiling: Exits 803.11 NA NA THROUGHOUT THE PROVIDED A-001 AND FLOOR & CEILING PLANS FOR MEANS OF EGRESS LOCATIONS. Table 803.11 This drawing has been prepared for the 807 ELECTRICAL COMPLY WITH NFPA WILL COMPLY ELECTRICIAN TO ARRANGE FOR AND PROVIDE Wall & Ceiling: Corridors 803.11 Sprinklered, Class C to be indicated project and is an instrument of 70 NEC UL INSPECTION AND CERTIFICATE. Table 803.11 Group B: Class C provided in Int. Exit service copyrighted by Mancini Architecture NATURAL OR NATURAL OR MECHANICAL EXISTING HVAC SYSTEM TO BE UTILIZED FOR PLLC. This drawing may not be copied or ut 808 MECHANICAL, Wall & Ceiling: 803.11 Sprinklered, Class C to be used, in whole or in part, by any party without RECONFIGURED SPACES MECHANICAL VENTILATION PROVIDED IN ALL SPACES HEATING AND VENTILATION. Rooms/Spaces Table 803.11 GB: Class C provided in Int. Exit the expressed written consent of Mancini VENTILATION REQUIRED OCCUPIABLE SPACES Group Stair. Architecture PLLC. Infringements or any use 810 ENERGY CONSERVATION, NEW ENVELOPE AND WILL COMPLY REFER TO 707. Floors 804 Grou of this drawing for any other purposes will be MINIMUM REQUIREMENTS MECHANICAL p B: Class II Class II to be provided prosecuted to the full extend of criminal law EQUIPMENT SHALL CONFORM TO ECC FINISH TYPE RATING PROVIDED CARPETTILES CLASS 11 KEY PLAN GYPSUM BOARD CLASS B FLAME SPREAD CEILNG TILE CLASS B FLAME SPREAD � i I PROJECT EXISTING __!___°----------_,__�LLI ------------- _ ® I STONY BROOK I\ ICHAELANGELO'S r ITRAVEL DIS 71' KITCHENJ MEDICAL o I 10095 MAIN ROAD MATTITUCK, NY 11952 E 0-1-- I I DRAWING- - - - - - w I c= - \ - - - - -I- I( I WING TITLE QI I ` i I BUILDING CODE & EGRESS -- ----- --- I r- -- --- TRAVEL DIST94L----------------- ------- -------- _ _ -------- TRAVEL DIST: 70' I JE I I I I SCALE SCALE AS SHOWN DRAWN BY ML I JE � I DRAWN FOR -- CHECKED BY MM PROJECT# -- z z r z On DATE 3/9/2020 - - - - - - - - - - - - - - - - - -L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - SHEET NO. N A-001 EGRESS PLAN ---- SHEET OF DEMOLITION NOTES: NO. REVISIONS DATE 6. ALL MATERIAL NOT DESIGNATED TO BE 14. THE G.C. SHALL COORDINATE PATCHING OF WALL TYPE LEGEND 1. THE INTENT OF THE SELECTIVE DEMOLITION SALVAGED SHALL BE REMOVED FROM THE ANY MATERIALS DAMAGED OR COMPROMISED WORK IS TO REMOVE ALL NECESSARY AND SITE AND DISPOSED OF AS REQUIRED BY, DURING DEMOLITION OPERATIONS (E.G. REQUIRED EXISTING BUILDING CONSTRUCTION AND IN CONFORMANCE WITH, ALL FIREPROOFING, CONCRETE SLAB) TO r (E) EXISTING WALL TO REMAIN APPLICABLE CODES REGULATIONS OR _ _ _ _ TO ALLOW ALL NEW CONSTRUCTION TO � MAINTAIN CONTINUITY OF REQUIRED FIRE PROCEED. THE DEMOLITION DRAWINGS DO REQUIREMENTS. VERIFY WITH OWNER ABOUT RATING, ACOUSTICAL SEPARATION, ETC. E __ — — — DEMO — EXISTING WALL TO BE REMOVED NOT INDICATE ALL ITEMS TO BE REMOVED — ANY COMPONENTS OF SALVAGE VALUE. THEY ARE TO BE USED AS PART OF THE 7 ALL DEMO15. THE G.C. SHALL IDENTIFY EQUIPMENT. AND DEMOLITION KEY NOTES: GENERAL CONTRACTOR AND DEMOLITION PERFORMED LIL1TIOOIN A MANNER WHICH COMPLIESN WORK SHALL BE MATERIALS TO BE RELOCATED AND SUB—CONTRACTOR'S ON—SITE SURVEY TO WITH ALL APPLICABLE CODES AND COORDINATE THEIR METHODS OF REMOVAL, DETERMINE THE COMPLETE SCOPE OF THE SAFE STORAGE, INVENTORY, ETC. WITH REMOVE EXISTING INTERIOR PARTITIONS AS NOTED. PATCH DEMOLITION WORK, AS INDICATED ON THE OWNER'S REPRESENTATIVE PRIOR TO START REQUIREMENTS. ADJACENT SURFACES AS REQ'D TO MAINTAIN UNIFORM WALL CONTRACT DOCUMENTS AND REQUIRED BY 8. THE G.C. SHALL SECURE ANY NECESSARY OF DEMOLITION WORK. O THICKNESS & CREATE A SMOOTH SURFACE TO RECEIVE NEW 10 EXISTING TRANSACTION DEAL TRAY & EXISTING TRANSACTION ON—SITE CONDITIONS. CONTACT ARCHITECT AT DISCOVERY OF ANY DISCREPANCIES. CONSTRUCTION AND/OR DEMOLITION PERMITS FINISH. (TYP) WINDOW TO BE REMOVED AND FILLED IN BY LANDLORD. PRIOR TO STARTING DEMOLITION WORK. 16. THE BUILDING AND SITE SHALL BE LEFT REMOVE ALL WOOD WAINSCOT TRIM, AND GYP. BD. DOWN TO NO. ISSUED DATE - 2. THE GENERAL CONTRACTOR (G.C.) WILL BROOM CLEAN AND DRY AT THE REMOVE ALL EXISTING FLOOR FINISHES DOWN TO EXISTING 11 METAL STUDS ALONG WALLS 1 80% 9. FIRE EXTINGUISHER REQUIREMENTS OF ALL — — — COORDINATE THE SCHEDULING WITH THE COMPLETION OF THE SELECTIVE DEMOLITION SUBSTRATE MATERIAL. PATCH SUBSTRATE MATERIAL TO COMPLETION SET 4/16/20 APPLICABLE CODES SHALL BE STRICTLY WORK. OWNER'S REPRESENTATIVE AND SHALL MAINTAINED IN ALL AREAS OF DEMOLITION O MATCH. PREPARE SLAB TO RECEIVE SELF LEVELING REMOVE ALL FIREPLACE COMPONENTS. 2 95� COMPLETION S INFORM THE OWNER'S REPRESENTATIVE OF DURING ALL DEMOLITION OPERATIONS. COMPOUND ONE ENTIRE FLOOR AS DIRECTED BY 12 E TS. FIRE BOX, DUCTING, ET 5/14/20 4> II THE SCHEDULE OF DEMOLITION PROCEDURES 17. RESTORE ANY SURFACES OR FINISHES WHICH MANUFACTURER DECORATIVE STONE. CAP OFF ANY GAS LINES. 3 COMPLETED CONST. SET 5/22/20 IN ADVANCE OF STARTING ANY DEMOLITION. ARE SCRATCHED, MARRED OR OTHERWISE 13 EXISTING WOOD STEPS AND RAILING TO REMAIN. 4 COMPLETED CONST. SET 6/4/20 II 21 10. PROVIDE TEMPORARY MEASURES AS DAMAGED BY THE INSTALLATION, MOVEMENT DISCONNECT ALL EXISTING DEVICES, SWITCHES, JUNCTION II WORK MAY NOT PROCEED UNTIL THE REQUIRED TO MAINTAIN REQUIRED OR REMOVAL OF ALL EQUIPMENT BOXES AND RECEPTACLES ON EXISTING WALLS TO BE 5 COMPLETED OWNER'S REPRESENTATIVE PROVIDES THE EMERGENCY EGRESS FROM THE BUILDING AT ASSOCIATED WITH DEMOLITION PROCEDURES DEMOLISHED. REMOVE ALL ASSOCIATED CONDUITS AND WIRING REMOVE EXISTING COFFERED GYP. BD. CEILING AND FRAMING CONST. SET 6/12/20 G.C. WITH WRITTEN ACCEPTANCE OF SUCH ALL TIMES DURING DEMOLITION PROCESSES. O BACK TO EXISTING POWER SOURCE. EXISTING RECEPTACLES 14 IN ITS ENTIRETY. DISCONNECT AND REMOVE EXISTING LIGHT 6 ISSUED FOR PERMIT 7/7/20 E G. CONTAINERS ETC.). FIXTURES AND HVAC REGISTERS. SCHEDULE. SCAFFOLDING, , 11. THE ARCHITECT SHALL HAVE NO 18. CONTRACTOR TO PROVIDE TEMPORARY TO REMAIN ARE TO BE REWIRED TO NEW ELECTRICAL BOX RESPONSIBILITY FOR ANY HAZARDOUS SUPPORT LOCATION AS PER CODE. MEDICAL BX CABLE WILL BE REMOVED. CERAMIC TILE UNDER DOOR WHERE TILE IS BEING 3. THE G.C. HAS AN OBLIGATION TO NOTIFY COLUMNS AT ALL STRUCTURAL LOAD THE OWNER'S REPRESENTATIVE 4 DAYS IN MATERIALS IN ANY FORM AT THE PROJECT BEARING WALLS TO BE REMOVED UNTIL REQUIRED FOR ALL MEDICAL USE AREAS. 15SAW CUT 1 , 15 15 ADVANCE OF ANY INTERRUPTION TO SITE. THIS INCLUDES, BUT IS NOT LIMITED INSTALLATION OF NEW STRUCTURAL MEMBERS. # $ CONTACT ARCHITECT UPON EXPOSURE OF 4 REMOVE EXISTING ELECTRICAL SUB PANEL REMOVE ? ' Stony Brook Medicine BUILDING UTILITY SERVICES. SUCH TO ASBESTOS ASBESTOS CONTAINING EXISTING DOOR AND FRAME AND ASSOCIATED 21 I 11 NOTIFICATION APPLIES TO WORK PERFORMED PRODUCTS, STRUCTURAL CONDITION AS REQ. 16 MATERIALS AS INDICATED. DURING NORMAL AND OFF—HOURS. POLYCHLORINATED BIPHENYLS REMOVE EXISTING PLUMBING FIXTURES IN THEIR ENTIRETY. ALL (PCB's), LEAD, OR ANY OTHER TOXIC 19. ALL WORK SHALL CONFORM TO THE LATEST SUBSTANCE. EDITION OF ALL APPLICABLE REFERENCE O PLUMBING SUPPLY AND WASTE LINES SHALL BE CAPPED OFF 17 EXISTING DOOR TO REMAIN. L"IF 4. DEBRIS SHALL BE CONTAINED ON SITE IN AT THEIR SOURCE. PREP FOR INSTALLATION OF NEW DUMPSTER/ROLL OF CONTAINERS PER TOWN 12. IF HAZARDOUS MATERIALS ARE DISCOVERED SPECIFICATIONS, TO GOVERNING BUILDING FIXTURES. OF SOUTHOLD REQUIREMENTS. CONTRACTOR DURING THE COURSE OF DEMOLITION, G.C. IS CODES AND TO THE REQUIREMENTS OF 18 REMOVE EXISTING FINISHES, GYP. BOARD & FURRING. Fr ]� 13 IS RESPONSIBLE FOR ANY APPLICABLE TO NOTIFY THE OWNER'S REPRESENTATIVE AUTHORITIES HAVING JURISDICTION. 6 REMOVE EXISTING CEILING TILES AND CEILING GRID IN ITS MANCINI Lo I PERMITS AS REQUIRED BY THE TOWN. IMMEDIATELY O ENTIRETY. REMOVE EXISTING LIGHTS AND HVAC REGISTERS. 19 REMOVE EXISTING GYP. BDLin ., WOOD FURRING & CMU. O ARCHITECTURE --- 5. ALL AREAS OF DEMOLITION ARE TO BE LEFT 13. THE GENERAL CONTRACTOR SHALL O REMOVE EXISTING POURED CONCRETE STAIR. PATCH AFFECTED REMOVE EXISTING GYP. BD. & METAL FRAMED CEILING IN ITS CONSTRUCTION BROOM CLEAN AND SECURE AT THE END OF COORDINATE ALL DEMOLITION WORK FLOOR AND WALL AREA TO RECEIVE NEW FINISHES. 20 ENTIRETY. — — — EACH WORK DAY. DOCUMENTED ON THESE DRAWINGS WITH ALL REMOVE DOOR AND FRAMES. PREPARE OPENING TO BE FILLED 222 Middle Count Rd Suite— — — — — — — — — — — — — — — mul WORK DOCUMENTED ON THE MECHANICAL, Country to 314 ELECTRICAL, AND PLUMBING DRAWINGS. O MATCHING EXISTING DEMISING WALL. REQ'D TO MAINTAIN21 EXISTING FINISHES AND FIXTURES TO REMAIN. Smithtown, NY 11787 UNIFORM WALL THICKNESS & CREATE A SMOOTH SURFACE TO T: 631-979-0104 RECEIVE NEW FINISH. F: 631-979-3445 REMOVE ROLL DOWN SECURITY GATE AND ALL COMPONENTS. 22 EXISTING BUILDING COLUMNS TO REMAIN. info@manciniarchitecture.com O9 PATCH ADJACENT SURFACES AND CREATE A SMOOTH EXISTING ENTRANCE SURFACE TO RECEIVE NEW FINISHES. 2 1/410 =1 ,-O„ ,��RED q qc e 0 - - - - - - - - - - - --- - -- - - - - - --- -- - -- - r_ 't I �Q' FN y 1 H _ I `O 18 8 \ 6 clv I This drawing has been prepared for the indicated project and is an instrument of H6 I I service copyrighted by Mancini Architecture —I 6 I 9 I I ui may not be used, in wholeodrawing copied inpart, by any partywthout _J2 2 2 4 I I I I the expressed written consent of Mancini � I 17 Architecture PLLC. Infringements or any use of this drawing for any other purposes will be / 6 I I 1 prosecuted to the full extend of criminal law 2 KEY PLAN I I I I I 10i/5 –� I 14 I 3 I 19 3 IIIII I I I / ' IIII II I I -6- III11I IiI 66 - U / LC_IIII�III�IIIII 22 --3---- - 2 3 22 II II 1 —3——— - - -1-6 — —�--�— IrIr --=—=—_---_---—3--- ----1 --- ------I1 3 22 L - - - - - - - - - - - - -- - - - —� 2 19 IF 12 5 19 ,9 0 II 2 h 2 20 I - — — PROJECT 1 3 I ,6 17 S T O NY BR O O K MEDICAL 6 10095 MAIN ROAD MATTITUCK, NY 11952 6 DRAWING TITLE 18 DEMOLITION PLA N to 7 'o 3 SCALE SCALE AS SHO WN 2 DRAWN BY ML 10 1 DRAWN FOR -- I 18 I CHECKED BY MM I I I I I PROJECT# I -- - DATE 3/9/2020 I - - - - - - - - - - - SHEET NO. — — — — — — — — — — — — — — — — — — — — I I I D- 1 00 PROPOSED FLOOD PLAN ---- SHEET OF NO. REVISIONS DATE .I ► '� WALL TYPE LEGEND (E) EXISTING WALL TO REMAIN ® NEW WALL (SEE TAG FOR TYPE) EXISTING DRAWING LEGEND BATH - 01 DOOR TAG (SEE ACCOMPANYING SCHEDULE) li WALL TAG (SEE WALL TYPES ON A-500 E FOR DETAILS) NO. ISSUED DATE t"T BLOCKING SCHEDULE 1 80% COMPLETION SET 4/16/20 EXISTING E I PLYWOOD BLOCKING AT: NC NURSE CALL 2 95% COMPLETION SET 5/14/20 BATH 1. ALL CABINETS LARSEN'S ARCHITECTURAL SERIES 2409—R4 3 COMPLETED CONST. SET 5/22/20 2. TELEVISION FEC WITH FULL PANEL, CLEAR ACRYLIC 4 COMPLETED CONST. SET 6/4/20 U 3R E ALUMINUM WITH 34" ROLLED EDGE 5 COMPLETED CONST. SET 6/12/20- E BATHROOM ACCESSORIES SEMI—RECESSED. o I 4. GRAB BARS 6 ISSUED FOR PERMIT 7/7/20 5. WALL MOUNTED EQUIPMENT � 5 Stony Brook Medicine I- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 124'-21" EXISTING ENTRANCE - c, �44 - MAIRNOCINI 2 1 /4 1 ,_G„ ARCHITECTURE I\- mul CONSTRUCTION 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 T: 631-979-0104 112'-41"+/— F: 631-979-3445 info@manciniarchitecture.com I I I I I 9'-2" 9'-0" 7'-6" 13'— 10'-0" 10'-0" 10'-0" 9'-0" 5" 9'-0" _I - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - — — — — - - - - - - - - - - - - - I 6D1D D I D fi p I RED q A �, p N C pc 7/ B EXAM EXAM EXAM EXAM A OFFICE/MGR �''� i �B] E I 109 rn 107 A 106 103 101 WAITING "✓;T� 0 100 - _ -' rAKI/nnnkA A 113 `r E 12 r "I 9T STORAGE 038170 �pQ' oL0 A OFNE`N CONSULT D - D — — —— D 114 ri2 11 D —— — 07 q6) ° (03) 02 A _ _ A p ;. 09 0 1 4,—�„ I FEC �� I I �A] D EXIT I ` — A MA STATION A A ( �� a This drawing has been prepared D D `� 9 Pep d for the 110 o 0 indicated project and is an instrument of 14 13 I I.T. zo service copyrighted by Mancini Architecture 4'-2" 2'-0" 2'-6" 8'-3" 8'-0" 11'-0"LO 9, „ " " ., " G „ 115 —0 9 —0 5 —7 2 —6 119-11" 5'—10 1 —0 5 6 —7 � I PLLC. This drawing may not be copied or I used, in whole or in part, by any party without C D D (D5 1 the expressed written consent of Mancini 0 � ° D � I 6'-0" I Architecture PLLC. Infringements or any use A A 1 1 q I I 1 —— • A 08 —— — — — 1 04 I —N of this drawing for any other purposes will be I—_ J A J` prosecuted to the full extend of criminal law PHYSICIANS I I OFFICE I G 1 I MA STATIOSOFFIT N 61 117 116 I I I MED ROOM B1 I BATHROOM MA STATION 1 o ABOVE I - ` 1.+ KEY PLAN 6'-0" 2„ 122 111 _ _ - A EXAM M 104 j A RECEPTION I I LO I I (0I I F EXAM OBGYN I I 1 102 Li I—a) -- I- —— STAFF LOCKERSA i EXAM i I I I POWER PROVIDED 00I I FOR EXTERIOR A E:oz 108 I I SIGNAGE. ALL A I I B f JANITOR BSIGNAGE D 4'-3" 1 i D 124 q2) D I I REQUIREMENTS STOND 16 I 41-800 5'—0 5'-7" 1 BE DONE BY 20 24 SIGNAGE COMPANY '111-61A 12'-0' �` A C �A] A A I A G EXIT D 1 I (D9 O 0 I 15 LO BREAK ROOM A q A A A 118 PROJECT % D D D D D 25 Q6 _ � D 2'—s" 17 18 1 19 I 21 231 - - — -- -- 28 -- PHL BOTOMY I B1 MEDICAL 10095 MAIN ROAD J q C REILAB MATTITUCK, NY 11952 E PICK UP 1 Oo EA EXAM WAITING - - I - - - 1 i 120 3 I PASS 130 DRAWING TITLE • EXAM 50o I THRU (° -ol 1 -�' 119 I D o BI BATHROOM F EXAM OBGYN IA o EXAM EXAM I A o I 1 125 128 `- 1 UP 3R 123 ° EXAM M_ PR POSED FLOOR •1 11 127 1 PLAN 3R E I 1 I E 00 1 C 1 I 1 1 D I D © 1 D D D D 1 D D I SCALE SCALE AS SHOWN DRAWN BY M L I - - - - - - - - - - - - - - - - - - - - - -- — - - - - - - - - - - -- - - - - - - - -.- - - - - - - - - - - - - - - - - - - -- - - - - - -- - -- - - - - - - - - - - - - - - - - - - - - - - - - — - - — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — - - -- - -- - DRAWN FOR CHECKED BY MM 124'-2'1" 10'-0" 1,-6 „ 1 10'-2" 5'-10" 10'-6" I 9'-0" 5' 9'-0" 5' 9'—O" I 5'01 10'-6" 14'-11" I PROJECT# -- Ar- DATE 3/9/2020 123'-21"+/— SHEET NO. A- 1 00 PROPOSED FLOOR PLAN 1 /4)1=1 ---- SHEET OF NO. REVISIONS DATE WALL TYPE LEGEND IQ (E) EXISTING WALL TO REMAIN 0 ® NEW WALL (SEE TAG FOR TYPE) O 0 O EXISTING DRAWING LEGEND BATH MULTI-DIRECTION ELEVATION TAG (SEE ---- - NUMBERS FOR PAGE REFERENCE & DRAWING NUMBER) LT - NO. ISSUED DATE DIRECTIONAL ELEVATION TAG (SEE 1 80� COMPLETION SET 4/16/20 NUMBER FOR PAGE REFERENCE & EXISTING DRAWING NUMBER) 2 95% COMPLETION SET 5/14/20 3 COMPLETED CONST. SET 5/22/20 BATH NC NURSE CALL 4 COMPLETED CONST. SET 6/4/20 ■ U 3R FEC SEMI-RECESSED FIRE EXTINGUISHER CABINET 5 COMPLETED CONST. SET 6/12/20 L 720 6 ISSUED FOR PERMIT 7 o I / / HATCH REPRESENTS MILLWORK (SEE s, ACCOMPANYING TAG FOR MORE DETAILS) Stony Stony Brook Medicine - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I EXISTING ENTRANCE MANCINI 2 ARCHITECTURE M U I CONSTRUCTION 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 T: 631-979-0104 F: 631-979-3445 info@manciniarchitecture.com I I I I I — — — — — — — — — — — — — — — — — — — — — — — — — -- — — — — — �' � EDAgC I Q N o EXAM 3 3 EXAMEXAM 3 3 EXAM OFFICE/MGR WAITING 038170 ' o N - 109 400 400 0 10s 400 400 103 01 OF NE`N STORAGE 100 CLEAN ROOM o I I 4'-0" 4'-0" 4'-0" 4'-0" I .4 113 iv J 10 10 112 CONSULT g 13'-8" o _ o o _ o 114 I ... 4OO N iV N N 5 This drawing has been prepared for the I.T. I FEC 400 I ( EXIT I indicated project and is an instrument of MA STATION 115 110 PLLC service Thisyd aw ng byMancini notnbe copied Architecture or used, in whole or in part, by any party without the expressed written consent of Mancini 2'-0" 2'-0" 2'-0" 2'-0" Architecture PLLC. Infringements or any use a of this drawing for any other purposes will be 0 2'-0" 2'- " _ I prosecuted to the full extend of criminal law z z O i -- - - - El- I I PHYSICIANS I I I--———J — — — N N — " OFFICE MA STATION I I I --------------- 7 A-401 „ 4'-0" 4'-0" I s —5 2 —9 KEY PLAN 117 11s I I �; MED ROOM 49-0't —o I I 11 122 6 3 3 EXAM MA STATION I RECEPT� 2 _ I I BATHROOM 40o EXAM 400 3 105 104 I T 102 T I I 1 i I 108 I o0i A-401 3 A401 ifl cO 2 111 EXAM OBGYN 400 2 2 -40- 1 _ _ Fol _ _ _ _ - �- - -STAFF 400 o I --- - 9 - o - - - - - - - - - 400 I 4 LOCKERS I I 400 0 2'-0" I N I I JANITOR 124 I oLO I 10„ 1 Pq 0 _ I I N N I I I I I EXIT O BREAK ROOMPROJECT 118 2'-0" nm STONY BROOK MEDICAL ° 10095 MAIN ROAD 0 2'_0" PHLEBOTOMY I iv N N iv MATTITUCK, NY 11952 CARE LAB i� 4'-0" 4'-0" 4'-0" _ 4-0to 12110 A-401 O WAITING DRAWING TITLE — PICKUP _ I PASS 3 EXAM EXAM 3 3 EXAM EXAM 3 10o PROPOSED I 2' 0" EXAM 120 7 m I TH R U 7 2'_o" 400 127 128 400 400 129 130 400 6 �` 119 I 400 o I ► I ► FURNITURE & 400 I I BATHROOM EXAM OBGYN I i -I UP 3R 123 �I 00 EQUIPMENT PLAN 3R O SCALE SCALE AS SHOWN I I I I N C I ( I I DRAWN BY ML I I I DRAWN FOR -- CHECKED BY MM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PROJECT# -- ( I I I I DATE 3/9/2020 SHEET NO. PROPOSED FURNITURE PLAN A- 101 ---- SHEET OF NO. REVISIONS DATE LEGEND TILE: ARMSTRONG DUNE 1774 TEGULAR Q" GRID L� GYPSUM CEILING EIL NG SOFFIT EXISTING CEILING TO 2'X4' MAXLITE FLAT PANEL NO. ISSUED DATE REMAIN LED 40W 4000K MLFP G2 1 80% COMPLETION SET 4/16/20 _ I 2'X2' M AXLI TE FLAT PANEL 2 95% COMPLETION SET 5/14/20 LED 40W 4000K MLFP G2 3 COMPLETED CONST. SET 5/22/20 4 COMPLETED CONST. SET 6/4/20 EXISTING 5 COMPLETED CONST. SET 6/12/20 CEILING TO 6 LED DOWNLIGHT 4000K REMAIN 6 ISSUED FOR PERMIT 7/7/20 It FLAT PANEL HVAC SUPPLY BUILDING STANDARD ' RETURN GRILL '.4° Stony Brook Medicine BUILDING STANDARD � EXIT SIGN EXHAUST FANMAiN N PROPOSED REFLECTED CEILING PLAN --'-" PROPOSED CEILING HEIGHT M U I ARCHITECTURE 2 1 /4"=V-0" CONSTRUCTION 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 T: 631-979-0104 F: 631-979-3445 info@manciniarchitecture.com I I I I I 'CoAED ^RC - - - - - - - - _ - - - - - - - - - - - - - - - -- - - - - _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - -- - - - - - — �5 P G / ti I I ILL I A '* r '-y 01 038170 0 STO GE I CL AN R OM EXAM EXAM EXAM I EXAM 0 FICE/ GR >. Or NE\ cV N 11 N 112 109 107IL 106 9 0 103 101 9 O I o" s' -:0:"] g' o" W TING ! 00 s' o" C NSUL 9' °" MAS ATION f This drawing has been prepared for the 114 indicated project and is an instrument of �0"] 9 I I PLLC. This drawing may not be copied or used, in whole or in part, by any party without g'-0" the expressed written consent of Mancini 9'-0' Architecture PLLC. Infringements or any use of this drawing for any other purposes will be 0 115 I I prosecuted to the full extend of criminal law • 1;_7;, 5" I KEY PLAN f_04 BAT ROOM N 2'-0" IWAZTATION 2'-0" 2'-0" 2'-0" A ST TION 1 6 ( 10 05 g, O„ 500 1 PH SICIA S E9 --_01 MED 00M 9'— " 9' °" EXAM 9 o XAM 9, 0„ , - - - - OFFICE - - - - - - - - - - - - - - - los — - - - -- - -Io5- — - - -- - - - REGETION - - - - - - - 1 2 2'-0" 2'-0" I g _ool JANITOR M 0 GYN I 124 12 b o N N 9, O„ I PROJECT 9' 0" STONY BROOK REAK OOM MEDICAL 11 I 10095 MAIN ROAD MATTITUCK, NY 11952 .. PICK UP I BATHROOM EXAM BGYN I WAI ING 10 0 12 P LEBO OMY123 1 5 � CARE B � 1 0 DRAWING TITLE 121 10'-0" PROPOSED 9' o" 130 EXAM I 9, o„ 9,—O» I g, o„ XAM s'-o" E1 s g' o„ 2s I 9, O" EXAM REFLECTED CEILING 141 1 PLAN 2'--0" Ll 19=_( 2'-0" 2'—O" 2'-0" 2'—O" 2'—O" 2'-0" 2'-0" '01SCALE SCALE AS SHOWN _ ' _ - o o 0 0 0 01 , 0 o DRAWN BY ML N N N I N N N ( N ( _- N DRAWN FOR T I I CHECKED BY MM PROJECT# -- DATE 3/9/2020 I I I I I SHEET NO. PROPOSED REFLECTED CEILING PLAN A- 110 ---- SHEET OF NO. REVISIONS DATE FINISH LEGEND L.� LABEL MANUF. PATTERN COLOR SIZE/FINISH LOCATION NOTES WALL FINISH EXISTING PT-, BENJAMIN MOORE - DECORATORS WHITE PM-3 EGGSHELL GENERAL AREAS BATHROOM ' PT-2 BENJAMIN MOORE - FORT PIERCE GREEN 712 EGGSHELL ACCENT WALL IN EXAM EXISTING — ROOMS PT-3 BENJAMIN MOORE - HIMALAYAN TREK 1542 EGGSHELL ACCENT WALL IN BATHROOM OFFICE/CONSULT PT-4 PT-4 BENJAMIN MOORE - IRON GATE 1545 SEMI-GLOSS DOOR TRIM PT-5 BENJAMIN MOORE - CEILING WHITE - GYPSUM CEILING SOFFIT ® RECEPTION NO. ISSUED DATE FS-1 ALL WALL COVERING TO 1 80% COMPLETION SET 4/16/20 PT-4 - WC-1 TRI-KES LANARK - ANCESTOR WHITE _ FRONT OF RECEPTION END ON AN INSIDE HARVEST R2-HA-01 DESK CORNER AT ALL TIMES 2 95% COMPLETION SET 5/14/20 3 COMPLETED CONST. SET 5/22/20 4 COMPLETED CONST. SET 6/4/20 CT-1 DALTILE FABRIQUE BLANC LINEN P685 12"X24" BAIIIROOHI HALLS 48" 5 COMPLETED CONST. SET 6/12/20 FRP LOWES ITEM: #110598 SMOOTH WHITE 4'X8' (#FSQF.32) JANITORS CLOSET 6 ISSUED FOR PERMIT 7/7/20 WALL BASE sl"� L - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - Stocky Brook Medicine - - - RB-1 ROPPE UBBER TOE BAS 123 CHARCOAL 4" COVE BASE GENERAL AREAS I FLOORING VF AMERICANBILTRITE - SONATA CEO-01 9"X48" GENERAL AREAS EXISTING ENTRANCE CT-2 DALTILE FABRIQUE GRIS LINEN P690 12"X24" FLOOR TILE BATHROOMS MAIftNOCINI 2 1 /4„=1 ,_o„ MILLWORK ARCHITECTURE VITTORIO #Q3005 M U I CONSTRUCTION QS-1 WILSONART QUARTZ OR EQUAL SUBSTITUTE TO TRANSACTION TOP BE APPROVED BY 222 Middle Country Rd, Suite 314 STONYBROOK Smithtown, NY 11787 HIGH IMPACT 820OK-16 WHITE T. 631-979-0104 PL-1 WILSONART LAMINATE DRIFTWOOD VERTICAL SURFACES F: 631-979-3445 HIGH IMPACT info@manciniarchitecture.com PL-2 NEVMAR LAMINATE S-6020T GUNMETAL HORIZONTAL SURFACES FLOOR TRANSITIONS FS-1 SCHLUTER RENO-U SATIN ANODIZED ALUMINUM _ TRANSI11ON FROM TILE TO VINYL LAMINATE 1 FS-2 SCHLUTER RONDEC-DB SATIN ANODIZED ALUMINUM TILE BULLNOSE \���PED G Rcy/ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - -} -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J _ - i — --'I — — — — L I �� 0321-70 2�- PT-2- PT-2- i- P -2 - Pt-2 -� IO - _RB 1-. �B=T ' __P f2B- -Z PT--11 - Z _PT�r- — — -PT--1- - 1 -v F_FJC MGR_ - - --1 ---- - -� T101 -T �- IVF --Z VF- -R f- _ —� - WAITING EXAM EXAM --,------ �0 pr--1- —CLEAN-ROOM EXAMS PT-1- -100 - I- PT-3 - 113 - --- - - 1-109 -1D7 -103- � ( This drawin has been �f06 0 1 g prepared for the indicated project and is an instrument of PTf - ----- ---L-- PT=T= _ , - -RB-1 � - service copyrighted by Mancini Architecture PLLC. This drawing may not be copied or -PT-4 - PT--4 - PT-4 - PT-4 - P.T-4 - - -Z used, in whole or in part, by any party without —�MA STATION Z_ e I _1 -T — — the expressed written consent of Mancini ----1 -110- _-�__-___-__�._ _ __ _(F_L _ _ Architecture PLLC. Infringements or any use CONSULT—,- -Prt= of this drawing for any other purposes will be -VF_ -RB=1 - �_T-1 prosecuted to the full extend of criminal law Z 115 31 41 1 - P`T� — - PTS _ -VFX - _RB RB-1 KEY PLAN --� Z -p �1 -- - -- - - — — R611 - 1-4 _ BAYNRO6M � _we-1 TO WRAP F'- --T-- �l _TO INSIDE CORNER _ ►--1 T _ WC=1 - -- Z CT-1 - = PHYSIC ANS MED-ROOM —1 }�, Z EPTI 22 I— CT---2 EXAM=OBGYN i EXAM -1 os - o� - -- -T OFFICE - — SvF- -P �_ — -�26 - [� 17 -I--MA STATION — � �T� �^ _ -L �fl—MUTATION VF I A401 --Z -VF-� - - - - 116 - _-- - _- -- =PT-11= - - - -- - - - =VF- NO. REVISIONS DATE 7 7 7 41 7 0 410 410 410 V.I.F 4'-21" V.I.F. 1'-2j" V.I.F. 5-5j" ±9'-0" AFF 'r 7'-6" ±9'-0" AFFff ±9 -0 AFF oEQ EQ. EQ. EQ. E . FINISHED CEILING o EQ. EQ. EQ. EQ. EQ. EQ. FINISHED CEILING o 2'-0" 2'-0" EQFINISHED CEILING . EQ. PL-1 MILLWORK FASCIA PL-1 MILLWORK FASCIA !BY MILLWORK CONTRACTOR BY MILLWORK CONTRACTOR PL-1 FASCIA PL-1 UPPER CABINETS ' PL-1 UPPER CABINETS b PL-1 UPPER CABINETS o 0 • / M LOCKABLE UPPER II 0 U NO. ISSUED DATE ° PT-1 GYP. BD. FINISH 1 80% COMPLETION SET 4/16/20 E 1 , - E PT-1 GYP. BD. 2 95% COMPLETION SET 5/14/20 N I PT-1 GYP. BD. FINISH N N SCHEDULED BASE 3COM20 C-4 I�� PLETED CONST. SET 5/22/ iv 6f, PL-2 MILLWORK BACKSPLASH 6" PL-2 MILLWORK BACKSPLASH N 6" MILLWORK BACKSPLASH 4 COMPLETED CONST. SET 6/4/20 r h' F _. h' �— PT-2 MILLWORK COUNTERTOP PL-2 MILLWORK COUNTERTOP PL-2 MILLWORK COUNTERTOP 5 COMPLETED CONST. SET 6/12/20 l & 6" BACKSPLASH & 6" BACKSPLASH LOCKABLE DRAWER 6 ISSUED FOR PERMIT 7/7/20 A Gi �-o I _� - PL-1 MILLWORK CABINETS o I E"r� E_EE PL-1 MILLWORK CABINETS r iv f� iv PL-1 MILLWORK CABINETS CI Stony Brook Medicine - ff f fl � � _ f If 0'-0" f-0 E I AIK L I � 0 -0 1'-10" E EQ. E I EQ. FINISHED FLOOR EQ. EQ. FINISHED FLOOR 2'-6" 1'L -6" FINISHED FLOOR 1' 6" 2' 6" 01 17 .1 2'-6" 5'-0" op IPA 01 1 6 SCHEDULED BASE 4 3'-0" MIN. 410— 7'-6" R OCINI 6 1MAiN 410 410 410 410 410 6 1 4 410 410 410 ARCHITECTURE M U I CONSTRUCTION MED ROOM ELEVATION BREAK ROOM ELEVATION EXAM ROOM ELEVATION ( TY 222 Smithtown, NY1tryRd, Suite314 1787 9 1 /2"=1 '-0" T. 631-979-0104 1 /211=19-01) 1 /2"=1 '-0" F: 631-979-3445 7 info@manciniarchitecture.com 410 7'-6" ±9'-O" AFF ±9'-O" AFF ±9'-O" AFF FINISHED CEILING FINISHED CEILING _ FINISHED CEILING Ln EQ. EQ. EQ. EQ. EQ.01 • PL-1 MILLWORK FASCIA ��FtED Al3C BY MILLWORK CONTRACTOR ��5 \�.?0 G,�'$V / 51 PT-1 GYP. BD. FINISH 0i '�' PL-1 UPPER CABINETS PT-1 GYP. BD. FINISH Ir 1 6" PL-2 MILLWORK BACKSPLASH �'. (', ;, I PT-1 GYP. BD. FINISH PL-2 MILLWORK COUNTERTOP _ PL-2 MILLWORK COUNTERTOP This drawing has been prepared for the — — & 6" BACKSPLASH ,� o o e f= `�- indicated project and is an instrument of service copyrighted by Mancini Architecture O PLLC. This drawing may not be copied or o PL-1 MILLWORK CABINETS o used, in whole or in part, by any party without j I — PL-1 MILLWORK CABINETS `O SCHEDULED BASE the expressed written consent of Mancini Architecture PLLC. infringements or an u ° se of this drawing for any other purposes will be 0'-0" 0'-0" -- - - - - - -- - _ - — 0•_011 prosecuted to the full extend of criminal law ilk 01 EQ. EQ. Q. EQ. EQ. EQ. EQ. FINISHED FLOOR 01 EQ. EQ. EQ. EQ. EQ. EQ. FINISHED FLOOR FINISHED FLOOR 10 KEY PLAN 4 13'-8" � 410 4 10 CLEAN ROOM ELEVATION 410 MA STATION ELEVATION MA STATION ELEVATION 8 1 /2"=l'—O" 5 1 /291=11-0" 2 1/2"=l '—O" 7 410 11'-6" 11'-6" 10'-6„ - 9' " AFF ±9'-0" AFF ±9'-O" AFF 0 FINISHED CEILING FINISHED CEILING o EQ. 61 EQ. EQ. EQ. EQ. FINISHED CEILING 01 PL-1 MILLWORK FASCIA BY MILLWORK CONTRACTOR PROJECT STONY BROOK MEDICAL PL-1 UPPER CABINETS PT-1 GYP. BD. FINISH10095 MAIN ROAD PT-1 GYP. BD. FINISH MATTITUCK, NY 11952 8 DRAWING TITLE PT-1 GYP. BD. FINISH INTERIOR 04 N 6" MILLWORK BACKSPLASH PL-2 MILLWORK COUNTERTOP PL-2 MILLWORK COUNTERTOP PL-2 MILLWORK COUNTERTOP & 6" BACKSPLASH -- — — --- scALE SCALE AS SHOWN 0 PL-1 MILLWORK CABINETS DRAWN BY ML j `n _ SCHEDULED BASE `� ` __ _ SCHEDULED BASE DRAWN F -- l .� OR CHECKED BY MM J� >> 00-09) A61 of-O" --- - - - - -- - -- - - 0'-0" PROJECT# EQ. EQ. EQ. FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR DATE 3/9/2020 6'-0" 2'-6" 2'-09) PL-1 MILLWORK LEG SUPPORT 3 SHEET NO. 3 410 410 4 6 1 400 410 410 410 PHLEBOTOMY LAB PHYSICIAN 'S OFFICE ELEVATION PHYSICIAN ' S OFFICE ELEVATION 7 1 /2$2=1 )—Off 4 1/2"=1 I—Olp 1 1 /2"=1'-0" ---- SHEET OF NO. REVISIONS DATE 11'-5" GYPSUM SOFFIT � ±9'-0" AFF FINISHED CEILING A-, ±8'-0" AFF FINISHED GYP. SOFFIT - - I - PT-1 FINISH 5 PT 1 PT 1 PT 1 S "TCP 1 � � *_ T6 50� 500 (SEE DETAIL)2" RETURN FOR WC-1 PT-1 FINISH 2 I I � 3'-4" 4 OPEN TO WAITING ROOM 4 500 500 500 NO. ISSUED DATE FS-2 FS-2 i FS-2 1 80% COMPLETION SET 4/16/20 C) I 3'-0" o o t1 1 3'-O" 2 95% COMPLETION SET 5/14/ 20 iv I Pot ( -� 1'-0" 3'-6" � 1 I PL-2 MILLWORK QZ SILL TOP 01 Zf COUNTERTOP 3 COMPLET% ED CONST. SET 5/22/20 I 1 -° to I v, -- i -- _ 1 D 1 0 - 4 COMPLETED CONST. SET 6/4/20 5 COMPLETED CONST. SET 6/12/20 - _ ► _ --- 6 ISSUED FOR PERMIT 7/7/20 o 0 0, 0 1 I 0 I 1 0 `r I — -p• I 0 I , r C° r • r� I ''� C -1 N I CT-1 " M ,l CV - - -- N 9 CT -1 �, St011yrClO : Medicine I-T t 11 I �_ - i'l u� � � o'—o" 3'-8" 10'-6" 6'-6„ 1 -271_610 �, 1 t-6„ SCHEDULED BA E PEDESTAL W/ DRAWERS FINISHED FLOOR ' ICINI 2 5 MAIN BATHROOM ELEVATION BATHROOM ELEVATION BATHROOM ELEVATION 410 410 RECEPTION ELEVATION C 1 ; 7 1 2"-1 '-0" 61 2"-1 '-0" 3 1 2"-1 '-0" UARCHITECTURE — — IVCONSTRUCTION 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 ±10'-0" AFF T: 631-979-0104 6'-10" 6'-6" 2'_0" F: 631-979-3445 10'-11" _ FINISHED CEILING ±9'-0" AFF ±9� info@manciniarchitecture.com � -0,. AFF FINISHED CEILING FINISHED CEILING PT-1 FINISH ±8'-0" AFF PT-1 FINISH FINISHED GYP. SOFFIT 5„ i i PT-5 ED ARCti SIGNAGE WALL BY OTHERS WC-1 WRAP TO INSIDE CORNER PT-3 WALL FINISH OPEN TO HALLWAY 038170 POCKET DOOR OF NE`N y I-- --- -- — 2'-0" TO HALLWAY PL--2 MILLWORK COLINTERTOP ILZPL-2 MILLWORK COUNTERTOP E-T • PEDESTAL W/ DRAWERS This drawing has been prepared for the indicated project and is an instrument of service copyrighted by Mancini Architecture too LOPLLC. This drawing may not be copied or used, in whole or in part, by any party without - 0 0'-0" 0'-0"0,_0,> the expressed written consent of Mancini Architecture PLLC. Infringements or any use FINISHED FLOOR 81_09, FINISHED FLOOR of this drawing for any other purposes will be prosecuted to the full extend of criminal law SCHEDULED BASE 3 2 410 410 KEY PLAN 0RECEPTION ELEVATION RECEPTION ELEVATION J 1 /21$=11-011 (Di /2»_1 ,-0„ ±10'-0" AFFq�_ 2'-0" 13'-9" ±10'-0" AFF FINISHED CEILING FINISHED CEILING 0 ±9'-0" AFF FINISHED CEILING WC-1 PROJECT ±8'-O" AFFIq�_ i _ PT-1 FINISH r- - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - PT-1 FINISH STONY BROOK =1NISHED GYP. SOFFITP�' I 5" WC-1 WRAP TO I 5 WC-1 WRAP TO I MEDICAL INSIDE CORNER I 500 INSIDE CORNER I 10095 MAIN ROAD I MATTITUCK, NY 11952 PT-1 FINISH PT-1 FINISH 71 4 4 OPEN TO � OPEN TO HALLWAY 1 500 DRAWING TITLE OPEN TO RECEPTION 500 i 77 RECEPTION ( I INTERIOR 6'-0" 5'-0" 4'-9" 1 QZ SILL TOP i ELEVATIONS I � I I PL-2 MILLWORK COUNTERTOP SCALE SCALE AS SHOWN DRAWN BY ML _ WC-1 I _ DRAWN FOR -- --- MI CHECKED BY MM iv N PROJECT# -- 0--0— �-��`j�'` 0 -0 DATE 3/9/2020 FINISHED FLOOR '9­/ CHEDULED BASE T FINISHED FLOOR SHE NO. E 3 2 3 5 2 A-401 410 410 410 A410 410 RECEPTION ELEVATION WAITING ROOM ELEVATION 4 ---- SHEET OF NO. REVISIONS DATE GYPSUM WALL PARTITION. SEE FINISH PLAN FOR DETAILS PL-2 MILLWORK WORKTOP 2'-0" GYP. BD. 1 1/2"THK. NO. ISSUED DATE PARTITION BY BULLNOSE CONTRACTOR EDGE COUNTER 1 80% COMPLETION SET 4/16/20 2 95% COMPLETION SET 5/14/20 3 COMPLETED CONST. SET 5/22/20 OUTLET 4 COMPLETED CONST. SET 6/4/20 5 COMPLETED CONST. SET 6/12/20 N 6 ISSUED FOR PERMIT 7/7/20 PL-1 LEG RB-1 SUPPORT Stony Brook Medici nc g,-O„ o 0 0 0 0o A7rd_ i '-0" SUSPENDED CEILING FINISHED CEILING 0 FINISHED FLOOR PLASTIC LAMINATE FASCIA BY MANCINI MILLWORK CONTRACTOR– FIELD FIT AT EACH LOCATION ARCHITECTURE MILLWORK SECTION CTIO N A T M A STA MUCONSTRUCTION 'I TION 8c WORKTOP K TO P 3 1-1 /2"=1 '-0" _ l 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 w STAINLESS STEEL CABINET SCREWS QUARTZ TRANSACTION T: 631-979-0104 ° TYPICAL COUNTER F: 631-979-3445 J� n info@manciniarchitecture.com 120' EURO CABINET HINGES (TYP) 4» ! GYPSUM WALL PARTITION. SEE ' ° FINISH PLAN FOR DETAILS PLYWOOD ADJUSTABLE SHELF i U* UPL-2 MILLWORK WORKTOP PL-2 MILLWORK WORKTOP 1 1/2"THK. 2'-0" 2'-9" BULLNOSE 4 o PL-1 UPPER CABINET EDGE COUNTER �,�ERED aRCy/ ~ oT�T PO G �� �\J Mei 1 1/2"THK. �" . ; " PLYWOOD BLOCKING BEHIND BULLNOSE 2» GYPSUM BOARD WALL BY FRAMING INTERIOR WALL EDGE COUNTER INTERIOR WALL w COUNTER WC-1 FINISH ON FRONT COUNTER CONTRACTOR = J" PLYWOOD SUBSURFACE 3ei� SUPPORT OF RECEPTION WALL SUPPORT 'y� o ypQ" a GYP. BD. ., F N0 . ° PLYWOOD ADJUSTABLE SHELF PARTITION BY GYP. BD CONTRACTOR PARTITION BY CONTRACTOR LO in ° CABINET PULL AS APPROVED C14 PLY SHEATHING N II— BY OWNER OUTLET i� GYPSUM WALL PARTITION. SEE This drawing has been prepared for the ivRB-1 FINISH PLAN FOR DETAILS indicated project and is an instrument of Nw Rg_1 service copyrighted by Mancini Architecture used, in whole ero`r in may b not an be copied or o w part, y y part without tten Architecture PLLCr'Infrinconsent of ements or any use Z m GYPSUM WALL PARTITION. SEE 0'-0" of this drawing for an other purposes will be iq- a FINISH PLAN FOR DETAILS 0 _0 9 y P P IT prosecuted to the full extend of criminal law FINISHED FLOOR FINISHED FLOOR (: MILLWORK SECTION AT UPPER CABINET MILLWORK SECTION AT RECEPTION MILLWORK SECTION AT ANSI 117. 1 2009 COUNTER KEY PLAN 7) 1 -1 /2„_1 ,-0„ 5 1 -1 /211=1 )-09) 2 GYPSUM WALL PARTITION. SEE GYPSUM WALL PARTITION. SEE GYPSUM WALL PARTITION. SEE FINISH PLAN FOR DETAILS FINISH PLAN FOR DETAILS FINISH PLAN FOR DETAILS 2'-1” 2'-1" 2'-1„ 01 1 PL-2 6" BACKSPLASH 0 PL-2 MILLWORK PL-2 MILLWORK - PL-2 MILLWORK COUNTERTOP CO COUNTERTOP C° COUNTERTOP I � I LOCK AT TOP PROJECT - _ - DRAWER S OK STONY BROOK N MEDICAL _J N (4) EQUAL SIZE LO DRAWER WITH 10095 MAIN ROAD FULL EXTENSION MATTITUCK, NY 11952 PL-1 MILLWORKr, METAL SLIDES, SINK BASE , ACCURIDE OR 8" STAINLESS STEEL ° ° I, PL-1 MILLWORK y Q EQUAL DRAWING TITLE CABINET BASE D TYPICAL SURFACE MOUNT MILLWORK HAND WASH SINK ,'ii w 0 o WITH ADA COMPLIANT o ° 1'-10" ° I o o o FAUCET. SECTIONS C\1 N N PLYWOOD N _ ? iv ADJUSTABLE a - -- -- --- SCALE SCALE AS SHOWN ° ° SHELF 3" 3" PL-1 MILLWORK —�` PL-1 MILLWORK SINK BASE i; DRAWER BASE DRAWN BY ML w RB-1 10" o ° 4 DRAWN FOROF -- o k M j { W CHECKED BY MM o PROJECT# -- 0'—0" d 0'_p" 0'—0„ DATE 3/9/2020 FINISHED FLOOR 3 FINISHED FLOOR �' 3 FINISHED FLOOR SHEET NO. 2'-0" 2'-° 2l-°»10 A-41 0 MILLWORK SECTION AT ANSI 117. 1 2009 SINK BASE MILLWORK SECTION AT CABINET BASE MILLWORK SECTION AT DRAWER BASE 6 . , 1 1/2" = 1 —0„ ”=1 '-0" ---- SHEET OF NO. REVISIONS DATE NEW 1 J" FURRING METAL " GYP. BOARD STUDS AT 16" O.C. 3a" METAL STUDS @ 16" O.C. I VERTICAL LEVEL LINE: CONTRACTOR TO ENSURE BAR IS LEVEL (1) LAYER J" GYPSUM NO. ISSUED DATE BOARD — BOTH SIDES EXISTING DOOR FLANGE COVER 1 80% COMPLETION SET 4/16/20 i i TO REMAIN ( I � 2 95% COMPLETION SET 5/14/20 EXISTING CMU WALL .. � i J" ALUMINUM SHIM PLATE NEW 1 METAL STUDS ON I INSIDE CORNER OF OPENING 3 COMPLETED CONST. SET 5/22/20 � 4 COMPLETED CONST. SET 6/4/20 WC-1 TO BE WRAPPED I MANUFACTURER MOUNTING FURRING OVER DOOR WINDOW AROUND OPENING TO END I I PLATE 5 COMPLETED CONST. SET 6/12/20 ON INSIDE CORNER ---� 06 1 -1 2 1 '-0'� I 6 ISSUED FOR PERMIT 7/7/20 2 X BLOCKING AT ALL BAR MOUNTING LOCATIONS WALLPAPER DETAIL 4 I I Stony Brook Medicine0 18" x I" VERTICAL BAR II II r I I SCHLUTER (SEE FINISH PLAN & BATHROOM ELEVATIONS) MANCINI I I I I I ARCHITECTURE 10'-0" I I r l r 3 METAL STUDS AT / I I "° FINISHED CEILING I I r / I 48 O.C. ATTACHEDmul CONSTRUCTION WITH CLIP ANGLE TO r I I 00 r r I I BOTTOM OF STRUCTURE I I I .-z 222 Middle Country Rd, Suite 314 3 METAL STUDS AT ( I / / I I Smithtown, NY 11787 / / 4 HIGH SCHEDULED TILE F.: 31-979-03104 445 16" O.C. ATTACHED TO BOTTOM OF DECK FINISHED CEILING I TILE BACKERBOARD info@manciniarchitecture.com w Q (WONDERBOARD, DUROROCK / I I z <a I I OR SUBMITTED EQUAL) (1) LAYER OF ( I I SUSPENDED CEILING UJ I I , GYPSUM BOARD — — — — — — — O I -- I 2 X BLOCKING AT ALL BAR I' — — — — — — — 8'-0" I MOUNTING LOCATIONS l FINISHED CEILING LL_ I ti T BRED qq • 2" RETURN: WRAP WC-1 cad C'y� TO INSIDE CORNER ��� �\J'P NG ,1 SECTION THROUGH SOFFIT @ RECEPTION PASSTHROUGH DETAIL VERTICAL GRAB BAR WALL DETAIL O 02 5 3„=1 '-0' 03 '�� s,7o ' oq O 1_12„_1 ,_0„ OF NE`N WALL NOTES: ROOF DECK 4 7/8 @ 3 5/8 STUD 1. ALL NON—LOAD BEARING WALL STUDS TO BE 20 GA @ 16” O.C. WITH 18 GA RUNNERS TOP & BOTTOM UNLESS OTHERWISE NOTED OR LIMITED BY THE This drawing has been prepared for the METAL STUD HEIGHT TABLE TABLE. SECURE 2" FROM EACH END @ 24" O.C. 3 J" METAL STUD DIAGONAL WALL TO UNDERSIDE OF ROOF indicated project and is an instrument of WITH FASTENERS REFER TO STRUCTURAL DWGS FOR LOAD BEARING STUD BRACING AT 4'-0" O.C. MAX DECK service copyrighted by Mancini Architecture REQUIREMENTS. PLLC. This drawing may not be copied or 2. ALL STUD WALLS TO BE BRACED FROM FLOOR TO ROOF STRUCTURE AT 4'-0" " 8 - STUD NEW SUSPENDED CEILING — SEE used, in whole or in part, by any party without O.C. CEILING PLAN FOR HEIGHT 4 7 $ @ 3 5 8 " STUD the expressed written consent of Mancini 3. STUD FRAMING TO BE PROVIDED WITH HORIZONTAL STRAP BRIDGING EVERY SOUND BATT INSULATION AT Architecture PLLC. Infringements or any use ALL O.C. ALL EXAM & OFFICE CEILINGS 1 LAYER 5/8" GYP. BOARD PL-2 LAMINATE TOP of this drawing for any other purposes will be 4. ALL GYPSUM BOARD IS WET AREAS TO BE MOISTURE RESISTANT TYPE. ( ) / p p 5. ALL GYPSUM BOARD TO HAVE 3 COATS OF JOINT COMPOUND TO BE APPLIED BOTH SIDES (1) LAYER 5/8" GYP. prosecuted to the full extend of criminal law TO AL JOINTS AND SCREW HEADS WITH 2" PAPER TAPE EMBEDDED IN FIRST SUSPENDED CEILING BOARD BOTH SIDES LAYER OF COMPOUND. BATT INSULATION SOUND 6. ALL OUTSIDE CORNERS OF STUD WALLS AND SOFFIT TO BE PROVIDED WITH (1) LAYER 5/8" GYP. PROOF METAL CORNER BEADS. BOARD, BOTH SIDES 38" MTL. STUDS, 16" O.C. KEY PLAN 7. ALL GYPSUM BOARD EDGES AGAINST MASONRY AND METAL OR WOOD FRAMES 3 MTL. STUDS, 16" O.C. TO BE PROVIDED WITH "S" BEADS. BATT INSULATION SOUND W/ TOP DEFLECTION TRACK N 8. ALL GWB SHALL BE INSTALLED VERTICALLY AND STAGGERED ON OPPOSITE PROOF SCHEDULED FINISH SIDES OF ASSEMBLY W/ FASTENERS. SCHEDULED FINISH 9. USE MOISTURE RESISTANT GYPSUM PANELS IN TOILET AREAS &EXTEND TO — 3 MTL. STUDS, 16 O.C. SCHEDULED BASE UNDERSIDE OF DECK '� SCHEDULED BASE 10. USE DUROCK CEMENT BOARD WHERE CERAMIC TILE IS SPECIFIED. COORDINATE SCHEDULED FLOOR LOCATION WITH FINISH ELEVATIONS, LEGENDS, AND SCHEDULES. SCHEDULED FLOOR 11. USE J" TYPE X GYPSUM BOARD IN ALL FIRE RATED WALLS AS SPECIFIED IN SCHEDULED FINISH WALL TYPES. SCHEDULED BASEMETAL STUDS @ MA STATION SCHEDULED FLOOR B METAL STUDS @INTERIOR C MAXIMUM NON—LOAD BEARING METAL STUD LIMITING HEIGHTS MAM:ETAL STUDS @ BATHROOM STUD SIZE 20 GA. 18 GA. 16 GA. 5/8" TILE BACKER BOARD (WONDERBOARD, 3 5/8" ® 1s" O.C. 1s'-2" 16'—�" 17'—s" A METAL STUDS @ INTERIOR DUROROCK OR SUBMITTED EQUAL) UP TO 3 5/8" ® 12" O.C. 16'-9" 18'-3" 19'-7" NEW INTERIOR WALLS 48" AFF ON BATHROOM SIDE 6" ® 16" O.C. 22'-8" 24'-9" 26'-6- _6" ® 12" O.C. 25'-0" 27'-3" 29'-2" PROJECT 8" ® 16" O.C. 28'-7" 31'-2" 33'-6" 7 1/4" @ 6" STUD STONY BROOK 8" ® 12" O.C. 31'-6" 34'-4" 36'-10" WALL TO UNDERSIDE OF ROOF MEDICAL DECK 10095 MAIN ROAD NEW SUSPENDED CEILING — SEE MATTITUCK, NY 11952 CEILING PLAN FOR HEIGHT EXISTING CMU WALL (1) LAYER 5/8" GYP. BOARD MILLWORK TOP SEE MILLWORK DRAWING TITLE 1 MTL. STUDS @ EXISTING METAL SECTIONS FOR MORE INFORMATION CONSTRUCTION BOTH SIDES 16" O.C. STUDS BATT INSULATION SOUND 2X4 WOOD BLOCKING PROOF ALONG TOP DETAILS & WALL (1) LAYER 5/8" GYP. (1) LAYER 5/8" GYP. BOARD BOARD 6" MTL. STUDS, 16" O.C. W/ (1) LAYER J" PLY PE TOP DEFLECTION TRACK SHEATHING BOTH SIDES SCHEDULED FINISH SCHEDULED FINISH �" TILE BACKER BOARD (1) LAYER 5/8" GYP. WONDERBOARD, DUROROCK OR M BOARD BOTH SIDES SCALE SCALE AS SHOWN SCHEDULED BASE SCHEDULED BASE ( DRAWN BY ML SCHEDULED FLOOR SCHEDULED FLOOR SUBMITTED EQUAL) UP TO 48" AFF I 3� MTL. STUDS, 16 SCHEDULED FINISH (SEE FINISH N " O.C. DRAWN FOR -- SCHEDULE) SCHEDULED FINISH CHECKED BY MM D FURRING WALLr-F1 EXISTING WALLS SCHEDULED FLOOR SCHEDULED BASE PROJECT# -- SCHEDULED FLOOR DATE 3/9/2020 METAL STUDS @ INTERIOR F 6" STUDS AT BATHROOM WALL G METAL STUDS @ INTERIOR SHEET NO. MILLWORK SUPPORT WALL A-500 WALL TYPES 01 - N.T.S. ---- SHEET OF NO. REVISIONS DATE DOOR AND FRAME SCHEDULE PLUMBING LEGEND UJ Z w W LABEL SYMBOL DESCRIPTION MANUFACTURER MODEL # COLOR/FINISH NOTES Q z Q DOOR FRAME = o O ADA COMPLIANT ONE PIECE SAN SOUCI INCLUDE K-4008 REVEAL QUIET—CLOSE o' KOHLER WHITE w o o ¢ COMPACT TOILET K-5172 ELONGATED TOILET SEAT >- Qva Q cn z w j W _r W U)NOTES Z Q � o 0 V) 0 x FAUCET: KOHLER WILLAMETTE W °- w N o N F- bi W w LAVATORY ADA COMPLIANT BRENHAM R99901-4D1 W o o ``' o KOHLER WHITE SIZE 'I FI I FI FI FI (n o o Q W o o Z K-1998—SS WALL MOUNTED SINK K-1999—SS8 SHROUD: BRENHAM Q `� w w w w w w w ir v> w W o = w # NO. ISSUED DATE MARK MAT'L EL. MAT'L EL r afz Q W W Y Y Y Y Y Y Z N o -J 0_ o F- WIDTH HEIGHT THICKNESS UJ Q z z o 0 0 0 0 o J o o Q > a w o c SINGLE COMPARTMENT 1 809 COMPLETION SET 4/16/20 Z Z z J J J J J J N 0 w � 0 0 W 0 w STAINLESS STEEL DROP IN ELKAY LR1716SC STAINLESS STEEL SINK 2 95% COMPLETION SET 5/14/20 1 3'-0" 71-0" 1 WD D2 HM F1 6X24 VISION PANEL X X X X X FAUCET: MODEL LD232SBH55C 3 COMPLETED CONST. SET 5 22 2 3'-0" 7'-0" 1 WD D1 HM F1 X X X X SINGLE COMPARTMENT # K / /20 o STAINLESS STEEL DROP IN ELKAY LRADQ202265PD2 STAINLESS STEEL AT BREAK ROOM, SOIL ROOM, AND MED / / 3 3'-0" 7'-0" 1�" WD D1 HM F1 X X X X 4 COMPLETED CONST. SET 6 4 20 SINK 5 COMPLETED CONST. SET 6/12/20 4 3'-0" 7'-0" 1�" WD D1 WD F2 POCKET DOOR X ROOM 5 3'-0" 7'-0" 1�" WD D1 HM F1 X X X X SURFACE MOUNTED HAND EXCEL XL—BW 6 ISSUED FOR PERMIT 7/7/20 6 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 0 DRYER 7 3'-0" 7'-0" WD D1 HM F1 X X X X 1-1/2" STAINLESS STEEL BOBRICK #B-6806 X 36" SATIN FINISH 8 3'-0" 7'-0" 1 WD D1 HM F1 X X X X HORIZONTAL GRAB BAR , StonyBrook Medicine 9 3'-0" 7'-0" 1 " WD D1 HM F1 X X X X 1ORIZ STAINLESS STEEL HBOBRICK #B-6806 X 42" SATIN FINISH 10 3 -07'-0" " 7'-0" 1 WD D1 HM F1 X X X X X X HORIZONTAL GRAB BAR 11 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 1-1/2" STAINLESS STEEL BOBRICK #B-6806 X 18" SATIN FINISH 12 3'-0" 7'-0" 1 WD D1 HM F1 X X X X VERTICAL GRAB BAR 13 3'-0" 7'-0" 1 WD D1 HM F1 X X X X RECESSED TOILET TISSUE 14 3'-0" 7'-0" 1 WD D1 HM F1 X X X X DISPENSER DOUBLE ROLL BOBRICK B-3094 15 3'-0" 7'-0" 1 WD D1 HM F1 X X X X SURFACE MOUNTED SOAP BOBRICK MODEL #818615 MANCINI 16 3'-0" 7'-0" 1 WD D1 WD F2 POCKET DOOR X DISPENSER 17 3'-0" 7'—O" 1 " WD D1 HM F1 X X X X ARCHITECTURE 18 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 18" X 36" MIRROR BOBRICK B-165-1836 M U I CONSTRUCTION 19 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 20 3'-0" 7'-0" 1�" WD D1 HM F1 X X X X 222 Middle Country Rd, Suite 314 21 3'-0" 7'-0" 1 WD D1 HM F1 X X X X X X ADA COMPLIANT WATER ENHANCED EZH2O Smithtown, NY 11787 22 3'—O" 7'-0" 1 WD D1 HM F1 X X X X FOUNTAIN ELKAY # LZSTL8WSLP STAINLESS STEEL T: 631-979-0104 F: 631-979-3445 23 3'-0" 7'-0" 1 WD D1 HM F1 X X X X KOALA KARE STAINLESS STEEL info@manciniarchitecture.com 24 3'-0" 7'-0" 1 WD D1 HM F1 X X X X BABY CHANGING STATION PRODUCTS KB-110—SSWM WALL MOUNTED 25 3'-0" 7'-0" 1 " WD D1 HM F1 X X X X L______J 26 3'-0" PROVIDE MUSTEE MODEL 63.600A 7'-0" 1�" WD D1 HM F1 X X X X CHROME PLATED FAUCET WITH VACUUM 27 3'-0" 7'—O" 1 WD D1 HM F1 X X X X • JANITOR'S UTILITY SINK MUSTEE MODEL 63M WHITE BREAKER, MUSTEE MODEL 65.700 HOSE 28 3'-8" 7'-0" 1 WD D1 HM F1 X X X X AND HOSE HOLDER, & MUSTEE MODEL 29 3'-8" 7'-0" 1 WD D2 HM F1 6"X24" VISION PANEL X X X X X 65.500 MOP AND HANGER SEE PLAN FOR DOOR DIRECTION JRED A 2iC �5 pOr�C Q � n i -A DOOR AND FRAME ELEVATIONS DOOR NOTES: 9 03$»0 nF'� 6„ 1. ALL OPERABLE HANDLES SHALL BE ANSI 117.1 2009 COMPLIANT LEVER HANDLES F NEVI _ OR PULL HANDLES. REPLACE ALL EXISTING HARDWARE TO BE COMPLIANT. 2. EXTERIOR DOORS SHALL BE PROVIDED WITH ANSI 117.1 2009 COMPLIANT THRESHOLDS 3. ALL PULLS, LATCHES, LOCKS, CLOSERS, AND ANY OTHER EQUIPMENT SHALL BE I ANSI 117.1 2009 COMPLIANT AND COMPLY WITH BC 1008.. 4. CONTRACTOR SHALL PROVIDED SUBMITTALS OF ALL ITEMS FOR REVIEW AND I APPROVAL PRIOR TO INSTALLATION. This drawing has been prepared for the 5. ALL FIRE RATED DOORS AND FRAMES SHALL SHALL BE UL LABELED. indicated project and is an instrument of 6. ALL HARDWARE IN FIRE RATED DOORS SHALL BE LISTED FOR USE IN ASSEMBLIES 00 ( OF FIRE RATING LISTED IN SCHEDULE. service copyrighted by Mancini Architecture PLLC. This drawing may not be copied or used, in whole or in part, by any party without the expressed written consent of Mancini 114111111 1111�1111111411�7111911111111�1111117JIJ71111111�71111117�7 Architecture PLLC. Infringements or any use LEGEND: PR PAIR D1 D2 F1 F2 AL ALUMINUM PVC PVC of this drawing for any other purposes will be EX EXISTING SS STAINLESS STEEL prosecuted to the full extend of criminal law FRP FIBERGLASS REINFORCED POLYESTER SSHM STAINLESS STEEL HOLLOW METAL HM HOLLOW METAL SC SOLID CORE KD KNOCK—DOWN VS VINYL STRIPS KEY PLAN PE POLYETHYLENE WD WOOD (BIRCH WOOD) HARDWARE MANUFACTURERS AND SERIES: HARDWARE NOTES: HINGES: 4J" MCKINNEY FULL MORTISE HINGES 1. ALL LOCKS TO BE KEYED TO BUILDING MASTER KEY. 2. ALL HARDWARE TO HAVE US26D FINISH. CONTINUOUS HINGES: MCKINNEY FULL MORTISE SAFETY HINGE 3. PROVIDE OVERHEAD STOP IN LIEU OF FLOOR STOP ON DOORS WHERE TRIPPING HAZARD LOCKSET: SARGENT 10 LINE — L LEVER EXISTING OR AS INDICATED. 4. FOR ENTRY DOORS & FRAMES, FINISHES MAY VARY BETWEEN INSIDE AND OUTSIDE CLOSER: NORTON SERIES 8501 & 9501 SURFACES. SCHEDULED FINISHES ARE TYPICALLY FOR INTERIOR FINISHES ONLY. EXTERIOR FLOOR STOP: ROCKWOOD #440 SERIES AND OR PUBLIC CORRIDOR SIDE OF DOORS & FRAMES ARE TO MATCH OTHER EXTERIOR FINISHES OR AS SPECIFIED ELSEWHERE. OVERHEAD STOP: GLYNN—JOHNSON 90 H HOLD OPEN MODEL 5. THE CONTRACTOR SHALL PROVIDE DOOR AND BUCK ASSEMBLIES AS SPECIFIED ON SILENCERS: ROCKWOOD #608 ARCHITECTS DRAWINGS AND DETAILS. 6. ALL LOCK SETS SHALL BE CODED AND OR KEYED IN ACCORDANCE WITH THE BUILDING ELECTRIC STRIKE: RCI RUTHERFORD CONTROLS REQUIREMENTS, CODES AND OR KEYS ARE TO BE DELIVERED TO CLIENT PROPERLY TESTED MANUAL FLUSH BOLT: IVES F6358, PROVIDE AT ALL DOUBLE DOORS AND OR TAGGED. PROVIDE 3 MASTER KEYS AND 3 PASS KEYS FOR EACH LOCK. 7. ALL FIRE RATED DOORS TO HAVE FIRE RATED DOOR FRAMES TO MATCH LABEL OF WALL. PROJECT ARMOR PLATE: ROCKWOOD — METAL DOOR PLATE #K1038 ALL FIRE RATED DOORS TO HAVE LATCHING HARDWARE AND CLOSER HARDWARE INSTALLED. EMERGENCY RESCUE: STANLEY DOUBLE ACTING PIVOT, DOUBLE LAPPED 8. WOOD DOORS BY VT INDUSTRIES STONY BROOK MODEL: HERITAGE STRIKE SIZED FOR EMERGENCY RELEASE STOP, ETC. CUT/SPECIES: PREFINISHED WHITE MAPLE MEDICAL BRUSH TYPE WEATHER STRIPPING ® JAMBS AND STAIN/FINISH: #CH 18 CHOCOLATE 10095 MAIN ROAD SIZED: PER SCHEDULE MATTITUCK, NY 11952 HEAD FOR PRIVACY 9. ACOUSTIC WOOD DOORS BY VT INDUSTRIES COORDINATOR: ROCKWOOD MODELS: HERITAGE SOUND CORE STC 49 SLIDING CLOSET DOORS: STANLEY SLIDING DOOR HARDWARE, MODEL #2841 CUT/SPECIES: PREFINISHED WHITE MAPLE DRAWING TITLE STAIN/FINISH: SEE FINISH MATERIAL SCHEDULE ICU STYLE DOOR ;f1: HORTON AUTOMATICS TYPE 310 TRACKLESS SO—EX SIZED: PER SCHEDULE OR APPROVED EQUAL 10. FRAMES TO BE EQUAL DOUBLE RABBET, FULLY WELDED TYPE 16 GAUGE, DRYWALL SLIP ON SCHEDULES PROFILE. PROVIDE MINIMUM (2) 20 GAUGE METAL STUDS AT JAMBS. FIRE RATED FRAMES ICU STYLE DOOR ; 2: NORTON AUTOMATICS TYPE 110 0—SX, OR SHALL HAVE THE SAME RATING AS REQUIRED BY THE DOOR. PROVIDE 14 GAUGE APPROVED EQUAL REINFORCING FOR CLOSER AND LOCK, 7 GAUGE FOR HINGES. CORNERS TO BE MITERED. PROVIDE 4" HEAD AT MASONRY. PROVIDE 8" HEAD AT AUTOMATIC DOOR CLOSERS (ONE SIDE ONLY). JAMB ANCHORS SHALL BE PROVIDED AND APPROPRIATE FOR THE WALL TYPE AND BE MINIMUM 16 GAUGE. SCALE SCALE AS SHOWN DRAWN BY ML DRAWN FOR -- CHECKED BY MM PROJECT# -- DATE 3/9/2020 SHEET NO. A-600 ---- SHEET OF - NO. REVISIONS DATE 1. 1 ISSUED FOR REVIEW 5/12/2020 i : 'I I . i �"-_z..../'.�� � ; i ;I ; i ;i I : i i H i: ; � SEE NOTE 2 SEE NOTE 2 ; A AND COORDINATION . i 1 it 1, ; I ;; : - ;! I i r 1 1:1 i � ............-­......­­­....I....... ...._..."..........".................................-1....I.......... .1-. .......I....I......................�......�.........­............................-I....... �.......-.111.....................�....�.......................................................................-..............�....�...............�.... i 11 ; , I 2 I 95% ISSUE ; ......... "" ..........­­­.­-­..­! !!I : _­11-­­.­_­I.... .............1-1-1..........................i 5/14/2020 i f'­­ ­ ""'""'' ' ' ' i!............................................... I I ------- ' " ' r 1: ; ;: i ;i i T I r i i ; i ;; I . : I r; i i !I ! '! :; . i__ t t; . 1 1 NOTES: ; i: I : i � 3 . :... I COMPLETED , i ;: � : : 5/22/2020 - 'i i ; I I (50) I l� ; i ; 1 I . . ;; ; 1, . . i I I ;; ; :: r i J1,1111 ; . ;1 .1 I ; :: ;; ......I..................... !� ;. ;: _F It !! ; I :. .: I � (.50) :ll' '"' -, I. LOCATION OF EXISTINO ROOFTOP 0AS FIRED AC UNIT 15 AS SHOHN. CONSTRUCTION SET '/ ! : , I I I i I i , i ! '' 1: :: ! I [A�. - - - LANDLORD 15 RESPONSIBLE To FURNISH AND INSTALL NEpq C7AS FIRM '' ; ; ; :: :. ! : : ; ...1". i . 1: ; 4 I ....... i ; ; COMPLETED 6/04/2020 'I , i I i ROOFTOP AC UNIT. REFER TO MECHANICAL SCHEDULES AND /'/" : I i I i ; i", p- I : , I 1 : i i : _._.. : -i i i I i ; I : ; / , i ! I—- ; i 1: ! i T I ; i: I : i ­­....�............. ; ; i: i ; : i ; i SPECIFICATIONS ON M-401 AND M-501 RESPECTIVELY. CONSTRUCTION SET : z i i : � f 1�...........�I. ...��­ - ­I I I_.; (810) 1i ;. i ; f: : / : ; : : I . i r : :*---"' ' __ ' ....."'.1."I� I : 11 i i : ; I ; I I 5 COMPLETED 6/12/2020 i � I ! I : 1! 1 : i ; I [ 11 1 ; : I ; � 2X5 12ke � 2. NEN CEILINCY MOUNTED EXHAUST FAN P41TH EXHAUST DUCT UP THRU ROOF. i ; i i ; VD 11 I : !� ; : : I Ili 1 1 i : ,I : ; . I i i : r ;i ; ; : � 1; i i I I--...-............i__ -201. ; : ! : i ; '' i � . F:� f_ .."'.11.I... ... ��:.. �:-.M! 1.........................................I.....,.-.-.i .,­....................................__.___..; ; i REFER TO DETAIL ON DRANINC7 M CONSTRUCTION SET : I �� . . -__- '. I .1i i i i ; : i � � ;: ! i r............................................_.......1......J 11....I.........................I.......T..............I -.....I i �: i ;� ; ;; . ; I I I : i I i ;; i 11 ! : ;: f ,; . � I i ; I : �: I ! I : i : . 1 1 i ;; � ; . i � L.........................j 6 ISSUED FOR PERMIT I i I i i ; 7/07/2020 1 , ! i ; ....... i ; 7 : / ;: 10� -I ! . . i ; I / I ...... �.....I ; i i :� : , 12x5 � i I i : I �� ; , . i ;: ; p i i ;: " �.............................................-1....­­il..... '_.!.....�......... i I 1 : ! i i f... .. - ....�!....I I....I...I..._".�..._.'...............I....I . .................f i I : 1 1 : ; : 1 1........... F--... I 1 i i . r : . / l2x6�/ !I i ; i i i 11 ! ; ; I 1. i 11 i i : I . i. . - I i I i ; I :1 ; VD li ; :i . i ; i 11 I 1!2x5 ;1 i i :1 ; ; :1 i :i :1 i ; ; : ! ;I :1 : : :; .. ;! i..........................j: : I : . i . � . ...'....-.1--------I-- i : ..... ......I.,........I...................................................................�......... ­­­.....­____'__'i ! i _....... I i : I .1.1.1.11.1......­­:... . ; : . . i I i : i ! 1......1 , i i ! i i .".11.... ...........1.1-... ­­ : i ; i i i : i I i ; i ; i : : i : ! I I i i i ; i : ; . i (50) 1 ; - i .......... .* *** i : : i ; ! ! : ! ; i : ; i i : i : i I j ! ; i ;; i I ­­ - 111.11"...'.....­­........ ......I..... i : .. "..'.....I........... ­...... � ; . i ; ... .... ..d` I I � ! i I ! � 1, ____ ; i . j ; ; i I . � i ; i i i ! i i i ; � . ; i �'i i i : ! i i i i ; � . ; i i ; i : : I � 1 i 5 1 i ; i � ; 1 ! "'!-% I . i . , 0, I i � : I I ; : i 1 . ; , 1 ! 1 1 I 1 i i ! i i i i I S 1 , 1 ! 1 1 ( >x"�........I",........... .............1 ; i ! '; ; - . i :"'___._"..'............�.........�.....................-f-.........I.........I....;_.___.­_­_­.......I...:1.11-1-- ! � : 1-1.1. ; i � ; . S I ; 1 ! ...'- �................... ...11 I._­.....I.........._'_­­­­ - ; i I i� /' ; ; . i ; ; i : r ; r . ; ; � i I ..._" I I ...­­.� ; i- ­­....I.. !_....... __...�....... � ..... .'.. ­ ­ �:­­­ i i ; .. .........I.....I........................�................- : - ­­...I - .... �...­­.­....1. I ; : ................................... 1.1� .1..........................�....................................j"-................ ................................. I... .....- - - - ­ * * **, ; ...".'r-1-1.0'.�'. - ....;::: -1­­I—-......I..................I....1.11.1.1.11'..,-.,....�..,-,--,�...................._­_'__...­...1.11................................... ..........................­­_...................­­­.....-...�...� .111.1.t. I., i.... I_.........­­1-1.1- ......--.--,.-,,­-----11-1.1, ...�.....:...........:... �-.4:. . . ....­­.­ i I L...... t ;_'­..­­_______'___ I�­;.­:;­:................ ..:...'!.._.._: : ; i : i ; . � ; � -_ I � , � I ; ; ; 1. i . ! i . : , : �' i I : i \ i i � I , , i � " I - ; ".-- I I EXISTING ENTRANCE MECHANICAL, PLAN A ' 11 2 1/4 91=11-099 - M 'a N C I N"' ARCHITECTURE M U I . ; I r . I . I ; 1 222 Middle Country Rd. Suite 314 : ; 7 i : ; ; ; Smithtown, NY 11787 . i r i . I ; ; T: 631-979-0104 i i . i I I ! ! I . I 1 F: 631-979-3445 ; info@manciniarchitecture.com ; I ! i i ! I I i ; : ! ; I I I! ; ! _.'....................I...I—-........I..................­­... .1...."I _. I ! i ­.....11.1 "....'.................................�.........-.---....-..--.---.-..-.----.-.---.-�---.--.-----...�.-,----...-.-..-....-.-.....,..I..............---1.....................__­­___.­­_­__�. . ! i ! ......*....*'***** : -----."-"..,-..,-.-.,-....--....----.------------.................................--.--------...-..-.-,.--,-.--.-.".-- ......... ...''... .. ....... ......... ........ ;r....... ......... .... ......... ....... ..... .. . .I. .. .... .......... ...­­­ I... .. .-...... ......... ......... ......... ......... ......... ......... ....... .......... .......... .......... .......... ......... .......... ...... ....I ! I : .. ; ___7 __T_- ! ....... ......... ......... .......- -4. ....... ........:­*.'.*.... qqq.... � : i ...... ...-1 I--.. ....... ..... ....I... ......... ­...... .... .......... .......... ......... ­..- ......... .....�... .......... ­­ ­­ ........ ........ ...... ........ ­... .......... ........ ......... ------- ------ .__ ­_ ­..­ -.-..- -.--. ........ ......... ........ ......... �....... ......... ........ ......... ....... ... ....... ......... -...... : i . ....i... ...... : : ; I : i I_-.......................t.........................t--,,- - ��.....T I I I—/ �....1-1......-.....................................�.....r.............................I..............................r.... I.............I..........[-.--.,.......�............................I...............................­­­........ ! ; r I : : �........................................:......................�.......­­............ ; I . i i ; . : - ..-.-- ; . ; i ; i : ; I : : . - L--------------I.--. i . : ; ; ; : : r I : : � ! : /1 : : : --------­----- : : : i : : : I : : : ---..--:-------------- - -­­ -- -.T .1_ I . ; --­ --.----.-.---1....... ---...-.............-7 i ' : � ; I -�� : ! i i i : / i I [ i i : i _­__ i i . . : ; ; ; '.__i�­__­' . ,r ; ; : .-­­­­1. ; ; V I ! I . I ; . � ; , i ; : i : .. : i : � : !��/ i 1� �11 ; i ; ! i . ; : i � '. : I : : � i : i ; : I/ : i / ! i : : : ! ! i ; : : // ; i , . ; i : : i -Z' .1., . : i : ! 1 �// : ; : . , : � : : ! i �/ � / : i ; , . ,_:..�_.-..:�-.�. - ........�.,.......___ i/ ...I..............I—.. � -_.1.1-.1-11.... I ; I I .1 .._................ ;� ­�...­ ­ .ij ".. ......................I.....�....�............-----__ . �...............................,­----------------� I I I ! 1, -.. ..-.--.-.I__�-------- I : : EXHAUST DISCHARSE I i i I ,I it I I_-....".11.............­ _---_-!T- - �­� .-.-------I,-- I i _________� : ; ==========V ; : i i ; . , : : i 1 i I 'i ; : z r r ;. i. I t: : -��' I.........----- - � i i . I - �.I ! i ; : T ': // : 1 f Z� a : Ti i i : il I i . i I ; I i i : ; ! 11 ;i �/11 ------z : : ;5 I : i . ; : :r . . 11 ! . ; ' :: . ___'7T :1 ! ir................... ___'..___ -- ; : [-ABOVE HUNO CEILIN& i ! � ;i : ! i I /� . i ; ;! �: ! it J �, :� . : ; : : ; I :. ; I f : ; :' �: 11 I'll //// I :� ; i : i: ;; i : : -.7" : ; I H : :. I : . ;: if T, : : I............. .. ; r : : : I ; I i : ! : .; 11 : : I i .. : . :1 . � :; : I � : - h : :1 . / :i :; I i: . : :: - �� 1 : k_ ...'...........�;.......�..................... 1".. I - I '_­................_... ........-.-�..----t;.---,.,-.-.,-.--...�� 11L.- _r 1�............................I 1. ______1 : i: '' i 11 . . �/ - ; . . I 1, A i ; :; :r 1, . I :: . 1! :� 41 1 i i i i i i I ; !! / : . (410) ; /I ii : I : (60) it i �� il (t'5) : " (65) i (6 5) i ' i I r i 1: : i 1: I i - i r - '"',-111 - _ _ .. I.........I....................�1 i ; 1: �: i : . ir if ;; N 71 ...............I ......­__'_'­_' . t ; i ! :i i /). i . � i � i 1/11 ; i i ­­­ I � : r ; i ---7 ...... i I i � .1 ... /�71111.Z_'.-1Z' 21"'..-------"**..,*...*...-, ....................­."..'..*­­.".'.'.""­...................�..................i,- ....I ...... -1-1 I 7- ;: /I �: I i i ; 11 � : _�/ j. I . -_�� � i : . . : �/ f :. ...I........ --..----.! � .11....I...................��/.' --- � ]: '"" . I � .---.. "T"I"Ph., i : t : . li�i­.......... -_­ � : i i i ; : i i : i : I 4 ; ! : � ; . : r . I i � i : .1 . i ! i : I i : ,A ; i : i. I . : . ' ' I ; �- : OFF t i - -, __1 ii ry i . I " . I : :; . i ; : � I : i : . I E "'i :: ; ; .­_.­­.......'__....= _ : : i : : : - � ; : . i : i , I : I , :. ; � ; :.1 -__-__.._"._.__.._4_ - _ �---- I ; ; i : i f : i ; ii I � : i i A : EXAM I i !I ; : i ; 1: 1- ; i ; : i ; i "I 11 � i :1 ­­.......I . ;WAITIN ; : ; i i (55) (55) �/" 0 ; :; ii �. [ in i : ! i I : . 1. I ... . ................... ... ...... r � ii ; i � i ; i i : .. :: ; : . i : � i i ; 1_7 . i,/i i I �..... r ! I ; . G . i ; : : 1� I : ..��... !////,////, I - '­­­­ ­­ -11-111"I � i; :; ; i ; Al i : 11 : i . i : � I i i 1 :: : tin ! 103 1 i : I i ; ; '� : i . i . . : ..:................".,.�.....=...I . ............ � ............I....�..........�: '­­ /' j j; ; _ '; i i _F : -1.....­....".,i i � ­­­_.......­­­­ - , . .. .­.­.........I...." -.11.111.......................�.................................. .................................. � - ­­­......I................ i . : i i . ­­� ; : -................... - . i ; , ,...�__ I ." ;; i : .­­­­­ . / I ; : : ... . A I . �..­: I . ; 11 .......­............. ............., .........................I...1.1..............................] .__.­­­­;; -.--... : ; i ; i I 11'_�I"i V� ; ; I i i i ! i ; I ..............................­_­­ 11........ : : ! i i ; '. S: ORAG LEAN ; - =-__ A. [ I i ..... . j i ; : /Irl**,* i . i r ; . /I I ......­­-­...... ... ­........................................... .......--.---.-- . ; I , I : . i : - ; ....... I.- i . : ; 11 . I I : i I : ; ; i ; i -,-,**' I— ; __�/ I : : i Tangel Engineering Associates, P.C. ' t . . i � � i / . 1 /' "-- ­ii ! : ; I i......... i � : � I i ; : i ! I � : . ; : : : I !! : : : i . � I : . / - i[ ' *''*' � i r - i i � : : i i � I ­- : I ; / . � � i 1; ! : i : i i / - i .......- �/ ; : I � � i :: __ i i i : i i . ; . ; : ; : : _; . I - !; ! ; : i : i : : 1\ ----...--. ................................I.i : i : � � i � i i . ' ; i ........... --,-,-- _ . 1 "/'. ...- 1 113 : t ; i I : : - 1� ! ; I/ :I �. 1i I I I � ..� � . 1; I i ! ; : ! i ; , ; . / 1 (100)!� � '\ . i i i i i . � ! i : :; 11, : : I � i i : Consulting Engineers . . : ; / ___ _ , . i........1.1?........i i . r i . I V/ �---- , . / . t i: i : i; : ; : , i ! j ! I i r : :4 . I �' 1 11 . ! z i . ; i� i ;: :; : : i : T 11" � / /r/�. : i :i : i : : i i i 5�' i -: :; /� : . I i V i ! ! / / . / : :i , . : i ! ; ; !I / ; i I � ; i � I , I: i . i : i ; ; \ i i ! I � :; 1i i ; i ,A f ; ! : , : I i i ; / i :; i i . : i ; . �'...... . -�.........�...........: I i : i ; I i ; , : i i 1: ! ; : i : , i . ....... . . .­­­ I � , : i i i I 1 : 7_,�__ ............�,___....-........: ..............1"; i I : / : i : :; i �� i I I ! i . ; ... : . I / 11 I—_ :/ 1."A .......ii i..........\ I " I � :...�. ,- � - : i . i/ : - .1 � .' ___' �_� ­ - ,: I ; /I IKTU 5 �� h �/. : 1 ! . - . . .i . . ... ..................�. : i / I. i ; I ...... ..... i ................................ ..../, i i _. ' -�­� ... .... . - ­.....__ . ;.­­­. ......_-.1__.--------" : : .// : i . ....- ; . I : i ; I i : 1.11111"..'....At'... . ­­ : : ... ; T . ! i� i I , I ; i � i l� : 4 .... 1 _. - - -I I.."L.-/,--; �i_______.___.._ . ; i I . ; . I L ......... . .; ..'--T....--. ...;....................___ ­­=__._" : . . ... -.1._.................. i : , : . I ! , ;t : . I : . . ; ; +_ i :r i . i I :. i _­ J . i� ,: : , I i i 1. i : i \ i i :: ; I i : ; : ; : / 'Co iIS I I �� i :1 VD�...­;_.............l.i.,...............:�L..._/_ -...........- i, / . , ____.___ ............................ - / X�.I ; 0. : / / -J......... ........................ I....................... .....�...... ..........I I I : . .. . I_ ....... i , I �///!�' i i I� . ! i i : i ! : / . : . I I/....... � i " ! 'Vo ! i i i i i i ; I ; �// . ; I \ VV : : I . i i i " ; . : i r : / i� . 11`1** -_­'_�­ -** C i ; : : q i ; : ; i i i i i I 'i ' i i i i : � i : i ; / I i ; V/ ­ 11 . i i I / : i I . _-, ......___.__.'____. : / / ' ; J VD _ . 1: VV V -",- - -1.......... ! I : . i \ � i ! i � � I i Ir i . : . ... I r ! : � I : : i 1 � i I I i i tk� i - I I I I" ACOUSTIC, � Vo ii 0 .r/,----. I..... - 1 285 Middle Country Road,Suite 208 i /// I I 1 ! � ' (110) j - - -�i_ - - .- - I i __J i ; : 1/1 ' 1 I i i i i i i I ! I I r i :1 7' i // : : : : � ; i . ; r I I . I ; il i ; . ­ i / : ; : : ;I­...........1111.1.1-i"'.1-......I..... . ... ... "...i... I I ­... -_�.OZZZ'�*/Z I" �//.Z/­­` .1 i : . : ; (D ; : � � 1 i � i __J � i i : i :. ...........[ ) ! i i I r /I . ; ! ' I - I` 1"' . V ; 7 � i i -.i i I i ; � : I . : I i i : i ­...I........I................ ; I *7 ! I I I 11 i ! !.Z.-i i 7/- , 16 . i � Smithtown,NY 11787 ; ..... 11-1. � LININO :i �"'/ /1 7 7' ' (........ ._+._­..'......._...[.,I........._1 4 i : '�.�'/�Z"�/' ';V./ "/'/�_//'/'/­i ; : _z' [T/i ­ -� //'�� ..... ......�' - ' � * i / ;� � r i i i I i � i i r I r .." i I . ..'.... i .19 T: ; : i I i : i i ; ; � . : ; . ; I ; : ! i i ! i I ; - _'_' : / __F , .. .. - I I ­....­., : ; � . i : 5 : ; : i ; i . ; I I i I I ! i 1 i ... i : i , �51 ' / : : i I ; /Z ��� . , le, � / �. : : -I - .. .___.......L�;�i , _*........... ��Z_=fl// / , YZI I- / / - - -I -2 I V � r /Z i 111.11.1.11 .................. . i / *) � Er--:2 .. _ .1 : .....W i � i i i - Z_ =_/Zz� ! ........*"*'*'**-- (5 / , '�/"- i / I U � i : : ; i : i i I _­_ '--.-- Phone:631.750.2800 I � ; i : : i i ; � . i i : ; !a! i i ' : i ; i : : i ; i i i 1 �- i I./ i /--24XI2 / / I-(50)1-f-11- ........... : i r I r : : ; i : . ; i : : i = - Fax:631.750.2744 ; i ; .m. i : : : ; i � i : i � . I ; � i RTU�I : : . ; ; . i / z � : . ...... ':�...........�...­­­.­­­..........­ . I I "I, i ; I I i i i ; i " f i ; ; . : i : : : i i ; , I T , i I ' \ ; ---, I� Ll. 11 � ; : i ; i i ; ; :'___'_'___(0i ) ......... '� / - ; (60) i � I I it, -, p __ I VD; - ­­ L____.'11 ___ : i i i i : : ; - i : / 1 ! * 1 ...' i- _: � ,; , i I i : _F I � I ; I i i ! i ! -1 � ; I i I Vp ,-.20XI2 I i tangelengineering.com ; . 4 - -1 - � � - _ I . � � i i i ; MI A i ! - - - I � i � * i � I 1 r : I r � f : i I s : i ".'' '� / : i ; ! i.........I_. ...... 1 ­:..'.�..... . - .....................I............. ....�............. .. ..�.L...'id......... 4 : - - - - � i . I . i __� i ..0 . � .... .....I.,....­-..... ..... ...I... .­ ­­............... ____'....I............ - . 4 .... .. i� ...I .... �.­ ..._....... ; i I......- . I . . , ��i­'.I I . i ' -1..........- - .........**- i i i - �' �"" : I i : 1. . i i I -J I ;i : I i I 0 i ; ; ; ! 11 ' '\ '; � ; I ; 0 i I : " I ; ; : . ' 1-*-*** I ! i i ; . : ; I I ;; S ; � . i i I I . i ; i i :; P i i - : / I i ; i t �' ; f! . . � I j ! i : . 'S�'� 1 i '! I ! ; : :5 I i : i :i " ! ! , � I I : , : ; : ; :i i "r i : I- _'y i : ; , I i i ; S ! ; ! � __'______.­..........- .­........................... r i ...­ . :11... ...'.11".11,111, ­­ ��........­­!­ � : ' . i ! '"";," - i (65) i " � 5 � : i . : i it i ; 1� I �- -___J- : ; : "//, i i t : i i ; I if i! i ­.. :1 . ; I . . . ; . : i . --- : T : !! � i I r, ; ; ;I ..... _.__ T T '' S I I I i d i� i 4; : I- — .1. . ''I : � ' 1 1 (" * �* - I--------- i I 1 - - - : I .­ ­.....-... . t - _ .%­...... ­...' .. i....... - . .....?;;-- � I ; . i� ; i i i ; t! I � i i ; ,; : i ;i i ; I . ; � ':"'//11 L i i I...........*'*'*'**­­-� : � : I : ",_ . 3. .:-1-**"* .-......-...­ ....­­_' / .. .........­I ............. Kii ""I . I .: I...'_­ ......= ..­'. ­­ ;/ ; , � I ; !: i 1. . ­...� � i- - - :*' 71*** ! I I ! i: � ! i i : . I i " I , I I i I...... .",I � !� I �1.1c .....i ii I 00 , " - - 1\ /e, ll /I 51 ! j i I I .. ; i � I I � I '� ; : \ This drawing has been prepared for the I - '...-, ;� i if ! : I "/ i i ;I � ­ , i . ! ., : .: : : : i . I if i � i !Z. : i ' 5oT i ! I i ; : i: ; c ; i i : i : : : I i ......- ; P ii � t; � � 1�5101` ; ; i I . I ! i ; . ;i ; : - I i i ;i :, i ; ; : : -11...I ............­­ ............... ... . ;;..."..". : i i i i : ........­­­ � . .. ­ . ­­­­­­� ­­�-�� . ......�­ : ; i ; - , i - � i i'.... � ... .- ....1 � ­ . i .. I -.11.11---I.......... ­­� ��I". ...'.�................................... !.............. - I .. ; ______' i : : - , :' ''* '* ­ " "'* ­ �'' " ' ; : , _'kE ; ................. : ! . . Vo ,. -4................... indicated project and is an instrument of ."__]". ACiOU& Ic . .... i-- �.�_........�: ­­. , , NOTES .... ­­­......I I ; I : ; , vl:�___.....�..... : I.......... -4.... ...... 11......Y.-.............�'--- , ....... __'. ... i ... .- --i �. .11,el."I'li"I"""7 �.....I.......1-1.1- ��� - ...L.-............................... ; ; i i I I I I --- ­­-4.....- i __.......1;i : i 1 ___­., ­_ .1.--1 � i i i i ; ; � f I '­­ : i : ; ............. ; I : ­ "I � I i ; i c . ; ; r : . . � ; ! i ; i : : ; I r : i ! : ? i ; ; i ! ; i : . I : [" . 'L INO , ! i ; i : I i : ' i 1. ! - --___. 1 . �...... _.. . t -...­.­ _. . .1 ..............I ' . . ....-....­­ � ; i : i 11" ; I . ; ! . ! . i I i i : ! I : . ; I i i i I i A . � ; I � 1 - ii ; ; i i ; VD 14 2 ir I I 1 _J �' ­ I ; ! 1-16XI : : ! � ; I � ; i i I '. i 0 i � ; i ; .....�... I . . i � ' ' Z///" i ; J _J ; i � ; i I : : : tt I : ; : � � ;i : : i 11 Z//z�Nzl�l/ �� � .'f'\/') J, i ....I . . . J i_....' ''....", "I �lr - Z lr/'� /'/Z"�­�'zXZ_z ! ! : I 1/1 i I I : i i - : i : r : IF i service copyrighted by Mancini Architecture - 111111.1._1 " ; i 4 ; i i f . .. '..' i � .... . � I I i I I i I I i ; F it'll I,- ..' I : :; �1 1 VO ' /" r � ; i ; �$x* 'Z �/ . r ! i 11 i : : /� Z...'. ,' ! . i : //,.---.---.-,.......t-- ­­_.____­..­..__.__.............--r-_ ; 'z...... . "I I T .. - . .+.....7 ; '// /I . 11,;� i . I ,. I ­.. ..... - I , I . ._..�...� -....­­. .....I/-I - .... i ! I . ;i : . ; : -, ..... � I ...... ........ , : : i PLLC. This drawing may not be copied or . . -7 'I., ! ! I .11 �� T - i ­ � " : , Z:: 1" /// //:�//'Z//_Z' ­.Z�ZZ/Z/`*`­­/"1��//�/'/;­� ' 11'' '"* i : i ' '/ " ..//z"/"""`-1:Zl� oo-`Z�/'/ . a: F : i p , / / . 1. � ; I I . X 'z - '4 : i ­ _// :r/ /-.-//I�'//, ,.7 Z,'Z/ .1 _&=....Z//Zz:� , i I:.................__.... ;_/' '�/1/27 '/" ,.,..z _/Z.. , I I ! � / . ; ��' 1 �� /' :'�................::-:::::---) I i ; i i ' I"... ....................� ......... ..­ i � : . ; : : i i I . : . z er, . �Z I i ; i . : I . I it ; : : : : ! : � I i ! 'r : � i ; r/'_............... ...... : Z��//_ _. r.-.'-*"':-i i I I i ; i . ! 1, " ! I i i i ...- -1111****-* : I i i ; i i __J �! : : i ................ _.."...1 T . : '/1 L ..� ... i - 1 1 ; . 1 ! , ZZ], Z . I : i : i : : ; : : .: : i : - : � i . z r ......:::::::::::::::::::.::::::t-i;�............. - ­ �...... : I ! I ,; / : I t ....7........................ i i l� 1 ! i ; i : . ,// i �'� -'! ; ; used, in whole or in part, by any party without - ; ; - I : I p i t . ; ; -11.1--.. ­............ ..- f .. ..1. "'.114..­...­................... / .......... � -.....�.... 1-1...... i - .� : . .:; i i : . ; . : I ! : : - - * !1 t� I J ! : !I : ! i : : : I . i i i : � � : ; : I : i i . ; i i : 1 . I : : I . ! / . : ;/ i i /I I i i : I � i i i i �� : /'" " I i ' I ! ;.'�':..:- - I i / i : � :: i . ................. I i i �: I I I I 1 : ; ; ; i i 'i ; ; ; i . : i ; ! ; . -/.­­ .... � I : ! . ' . : . i I I .. - ; the expressed written consent of Mancini ; 1 1 : : � � ! S r : . . ; : : : i : : I I i i � . : \ i : i : : ; i : ; I I I . i ; i ; : ; ! i . ..'...­.'.­ I——...............__...�! ... ­'! ­'�".'�'....' ... : i : ;PHYSIGIA' i i L.--11 I z : : : : . ; � ......... . ............. ......I......­­........................................ ........... -_ _..__._.'____ . ,I ....I__------ _ I—— !....... . . 11 ...'. - I i t : r// I - I i ___f7==______'___._- I i-- _ I_ - I . - F -A: __­ ----'___.___.____.._____. ' r 1 : - ': . - 11.1"..- : i I ; : N - i�...............................11 z - t. , .' :..f : .I i T � i I /. i 1; : :1 ;: i : r ; ; 4 'V � I 11 �/ �� I -_ ...-... Architecture PLLC. Infringements or any use :; I— . I V !I /.' � V zzl��'Z// / � i ,: **'�//. f �/ T IrOX12 I � : i . ­­....' ..if /� !I 1 : : . ! : ,� it '� I i ;: '4 : i: i '­ .1,i _� -1 "..'�- ----:�_- ... ..­........t--�....... I ; : I...... ­­­­­­­­..............�_­'..­�"'. I / ii � i ! .", , , ; : � ! ­­­­..... ...­ /Iii : . . . :: ; : . - -, . ­­­......-............. / ­ ..!'."..'X/ i � - '�'- //Zz/Z­ ��'/� ! i 15XI2 1 .111'. . I ..... /' ; / , ; i i : i : H . :1 . ; i i : i ; � ,/ : I '�-'- i ; .. ; :/.r J : i/ ;......- ;/ i i -�: . i : - / ____ I � fl of this drawing for any other purposes will be ;i .. ­ . I � ; "I /1 ! i i ; - I i 1! I . � i / "'-I6)d2/ 1 _."-IbA2 :� i ',,��I � ,..,-12xl2 / ; ......�/ ... . .....�... 2XI0 !1 t 12X5 ri ; I �24xI2' / ! : �"Y�,',q'T A T I Q N 1 IbxI2 : le"A /�>� /. 4x[. j�H2xlldi! H , : i 1000� OFFICE I �� �� z � ---"--I--,/// A "'� �.: :-'.--.'-- .-1 i 11 it : i I . . r I i ; --l.." . . r -, __ � : I- 11; i I . I ii -111. i : . i t : I / � � I . :1 I : i : i � / Is ' i i i � f! 41 I .........� I i ; �...........�..........; 4 i j _... I . . ' . %vv � �...........,. 4 1�1 C) 1 / i MED RO(2ij VV : ;� : i . I................... ........ .. ..­_�.......... - I I : : . i : K : : V : z � ii 14 1: ii : :; - prosecuted to the full extend of criminal law ' . I , . . . ......................._... I....... . 4.....................- - ......- . ' 'I ii . _L _71... _� ­_ . .. . ; I....�......I?. .I—.I i : ! I i 0 ! � i ......................... : . :_ . _­ - ... � i � ! 11'' ! . . ; i � : .. I __' �....4_- 1 ; I ; ***** i it ; : � . I : : : : I I ,� � i : :. ! i .. i ; I F : . ; i i : i . , :-----I- i! " i ; i� : //, i ..... .... I . /1 i . . ; . .. I : : i . ; 1 : zi: i i . ......�......- ' : :E 1� TION , ._ � -.1 i , ; i i : ; I : I . i : mlis __�m 1 '." : : I ___- :; : : i/ .........-i ............... . I -1­ i i - ..I I ......�...........-.....­ . i I i : 11 : � ­=.­;.��='; :........ I _-1-11- - ' '­ T*­ / . . i i . ; / . '1 f E XA XAM it ii */-, i ........ ......... �f�..... 22 ­......�.......�...../ � 11 ,THROQM ,..==!! '�) � : ; I % :"'. ')' ' ­­*......... "' I -4 /Ii i i ; ��/ : .................__�........... .....................�.............. - ! I . ..... 11. t .............._'..... i i .__­__! i ;;i i i : I :! . .: \ ; ,,,.,...' I : : I- .. � i : /' */ i-I... / : ii r -, : ; ....n......� ; . : ! !....­* 1 1 �/1 t i : ..' ­­­­­ .. I , ; IV 11...... ....__. 1; 105 1 : i i ; I i � i �' � ; i � :; i i : 4 �/' !; ;i ! it I : . �. i i I/i .......i .1.__...i... '10, I ....... ; . . : S . I . ; : 1-1-111",I 1.­: . ; I .1 . . - -...� i I . S . i ; i . i ; ! �/ i ! . 1; :; .: I I'll ACOUSTIC, : / f i _�.....��.... ..................: -11. ­_ ==.........�.... ­.....- � : I i 1; i - . !r! I I ; : i i ! : ; i E a ' I GYN I t : i �' i � 1'.';.'_.�' 'i r . �:r - i . .....�..................................I——............................... ;: I X ; ; '� t : I A // ! - ; - VV KEY PLAN � � ; I __J 1! ,/ E : i /i : i I I ; i __ _____J_ i 'I I i : 1! ........I -,...''....''41.11 .1........ . . .... ! �... �.............�........�................... : / 10 ­...***'***� ; i . ­­... %! � i i . _ONINOI�* : i / i ' : . : : ! � I :�,_ :----"---T-- ,__17 i I . il I : i j VV �// ... ........... - ____I , ; /" i / - (5 : i i : : z ' "I- '. ,' OF- NC-Vv ; 17- i : ; : i ; : .. i I : . i '/1 1 Z 1 : : . ; i ;� _....' /11 . ; i ; I . i ; I ; . : , ---I_- ...-I... ......... - / . !, _ ......=L'..-'.1............�...- -11� ..... L---- E NO /' . . -0............. ....' "I..."., ........ .1-1.1-1 : . i i. ...", : i .1-''_---- -11.. ­­ 111f�_ i - 111 A I...I ..... ......... -1.... ! _.� ../ �/. . /I I � ;. i ..._ "I..."., ­­...I.,........111.1......�__ ­­ _____­...­­....� i I ­ . � I .1 .. � 1. -11.......-1-11.....I -ill- ­­­­------�'­­_­­"I - � � , ; 1- 4-,"...".1- . . 1 ; : I.. .. .. ......- --I - : ! I�; ; , '_ - ��'7' -­ -.-- t---- ­ ,.----z .........- ..----.!_.___ ; -.-.---.-- -_ __.____. --_ ____.___ i - I ;; i: i ! ! /_�/,:�::j::�:�:�:�� ��::� . .. ..- ............................ i. - - !'_ - ; I '�' �­ I .......­­_­ �/ __ - ...........-I - ..----- j,- -­­ _11_1____-;: ­.- �........_____ - _ ' �_1-11 ki . i i ; 11 ,. I -- i _­­ �� . . I . it I . 1 ! '-,� / /I....... -- ...........................4// . .4 E. 71,11, r: r i 1 (140) ! ; 11 /i i i 7 : r __J _...; I �...� .. K i ; ; ; // '//.`/7./�+� : . 7x� -(5j5)--t--- - i i : � ! i - , ­­ ­ : . . �' .. : I I ; i i : t : ; ii V. ! i/ I .*'::.'T � : . : . i . ;; :.... ;' 11 i � � . / '*"* . A . \ i� : : ...** I I I i:**' *** i ; I : / . !! : '�_// ,/�..'/` /``/`/� `./��/-/���--/-`-/"�;,�/-/ A i " ...."11--...­ ., � ................................................. ; . . i r : i : : i i i i �; /. - i : : ! .: I ;,- -7- :: : i i : ! i 'I ; . - 11 � .............................. .................................................... .. :i : � ! : (65) i r/; : i .. : - "'�' I r ! i :i : ! ; i (410) ; ; ;: 0, .. ..:.; -*.,! . C� "� - � - i� : ..­­ //1 �// . : �� �; . * '***' *_ � �� .- - .. - . . ': ! ii ! t 1; , i I �'� .. _ __..J�..............��' : :: i ` �/ i . '' I '*** :1 . � i I �')\ i . � ". ...' ; i i : i i ; : : : I � � - ! i ; ' : 1 ! i i .__.­_­___ __; ;i - i � ! � 1/1 '.­..­--­­­.'_­-_ _. . . i :: : : - ! I I .--'...__1 ; - ..............�...................... . ..........=,...................... ...........____.. :.' . .. � ,.__­_... _- J ' i ; : ; , . :1 ; i ; : i : ir............---1 ! . . : ; i . :i : : // � i I �*'��r� f, : ­­""""' . ..... . I ­­ I" .."; -1._ ': I i . : i .. .".I';-� �4 i : I I q i . . . * /__� H" , ^ ;. I 4 12 d .. ! . /. r ­...-..._-­ -1 I., -I....... i i "I"I.-I-T -i �1 ­­...�1.�_...I : V z f ; i , � . 11 F_ - :1 . . '...' : "��'I �� -�' i ; ; .! / : . 1, ! il ; i r i i 1 d i . _. :1 f' : C: :; : �i / " � T - ; i; : 4! ! ! il I - 11 . i i . ...'.........1;.........I—— ­­­....­ ...­...........i­­_'______�"_ : i i i : i i � ; 1 ; :: ; ...........­­. *0 ..... , i .i E . .I._ ; ., "' -.....!.'�) � ; :! i � i :: '� � . ; :! '�'_­:.' "I 1-�o . . I I * I I !� �111 : i K i i i - / / i � : .�t' . :: : : ' �; ;: r * . . , ':...I �/ , - : I I �1; X ,:: i /.. ....................!........__ . ... : /" : ii �.� i /11 - I __J (65) I (65) : �� .. .......... ......................I.I.1,.................. -_J : .i ' : . ; � :: if i : i i i 11 .­­ � (150) : ' , : :: ­ : .1 i� ! : .': �; :i : . 10 ; : . K': : ,, =F. ... i : I / r . . :: : -.1...I.....�.................;�._l r_­_'� :; . ! C( :i : T t.- ­ I * 1 / ./ - ,JANITO�/ V i VD, � . 0 � k�"'.' '�'..' ' : ; i i .: it I...I � ­.... . r i , . :: i : ! I ; ' ; i I . ! ! ". . . 1 / ............ .1,.......� .......t .................�! ,; ...........�....= 1 i 1. . .i :1 . . : ! 1, - . I l� . , r ;I i.......... -.111- I. ___'...................... ......... i I k . � : .. � ;i i i : : I 1 il ....�....f.............. �...�..................................................�........I/'! I � .J :1 ;i t � UJ 4 � . :i i i ; i , t! . ;! ; I ; ...... .1 1 . .�. , : . i i �......­­.....................;'........I...........................I.............. � ; . i i i ; i _..__'...___ _........... ....­.......I..............................�. � _'.�_­.­........... :i I i �� ty . ; ; ii . i :.�. ..� :; : :11.1.1...I.....................1.11..................... I : � 1:(a 124,, i i :11 " 4 .... i i ; : I . ' � : 1�1 : ­:...- .. :............ ......... i - , : i i �/ ;i I I :; �i . I ...... - ; / //1' _.."..".­ � 4 : ! i/ �� � ; � �1 i : I vv 1_ i '. --- -_ I I : i : i ; �/ , _____._'., 1- : ,� , ----7 1,"'��;'_! i ! .T i : : , - " - t i r- - - - - V ! I �':"."-' _-i i : I : I 1-11-11-1-1111 - 1. . : I : : ..........­­ ­ I—............. 1 .1 It'. ./; . : i I I I , : . i : : :; /� : i; ! i � � - : : I I z : 4_ .... - ­ ; 11 -, - I ii V i .........�...�....................I__ .. I .; . 1�1' � :� �it': " i - - - - -I! V ;; I i � (75) 1 :1 � ! . 4 -- ..-Ji � ! '­ . , , ; � .- I X. I r : "I �: ./ f=1 i.111.11'.111=i, :1 V 1 RTU-2--\ " i ............�.......1; ---..-. i . ; ; ' ' i � ['� ; ! - � / * I M) il, :1 _41 : I / .-� '� _' ...I.­I.I. -t z'.-,1--',� - :! ! ' I .....I ,.� .,...................1 i- /."......111.1.11 .�-�i-'- . - vt. -...- " : ! ! . i - .... ­.....­--11-...' -....... i�' I .11.1.1111.11"... :/ . : C. i: � i I ! -/�' i i I .... ....... : -, /� . i i : .J.....__.......................__" , i � i i . . � . s / i ; . V I . � . : 11-1--...... . I................I � -_ :: ; ��..­..... .................�......--11,11-L.- ­__ - - ...'.....�.......IL-�...KI f , i i :: ; ; ; I , 1 i ! I I . : . , i ! : . 1, : ! i : ; :i . ; ; , !P � I ! I/....-.....�...........�.................... >-______4... . . ..................- I ..::*...: - . i I : : i . ; . i ; ; , : : . ; . . :i : I i ! ! V i 5 NOTE i 2 I ; , I q I 11 ��r� I! . /i: i I t ! ! i r / i! �� ; � 1 I'l . 'I .--............... ..... I : % i I i : : : i : ; . i .:.** . . . f i i i:�& I - ; : i . I !11_1 I : . . �/,. ! I e I .1 z ; ; : : ! . , �'_' !r..........­_.....- -Z. . i LL ! ! . i i. ; � . � i ! f . ; 6!38rol li ' // .i i � I : ; ! I : ;i I : I . i : : - ; i ; . I .. ... .4 .11-� I : � -.. --­.......' . .1.1 ... . i t � : i i i it : .: : I ' - , : i 11 4�11 -, : I i : ,l T i j , ' '/ � _6 " .../i I . il I'! �' '//"//"`//.//��`�����/-�-&-//��"/"�"" I ­­ ---..-z.......////.........////.......'...._.1ZZ//`­­/­' �,i,.,.//.// ' i i /I I i � ' . ]...........­ ..---...---. ;i --t : ' *'' '*' _: ­�­­ � i. t , 1! / . i . 7 : . . I i r ..rl " ':�//'./ --___: I ; ! ; � i ; I i I . ; ; . 1z" �". . ....' Z�oz ..' ­­.. ,.,., i ! i I ; I i : : .. .......ioz/­/� �zz­z�//�/'Zz/" / r i ; I : i ! i ; i ; : � i ; ..'� . I t _L if RTU-1 ; : i : i ; ! ; � I i - 1 �I � I i ; ..........i. % : - z . :I I i ; i � i i ; , ; S-'0'� , r ;: I - i i J : ! : I ; I--4-_---_____._T..__=--� -_-� : i �/- � ! 1 ; BPB I i : i i ! SEE NOTES 1 4 2 ; i I � : p : r ; I i . ; � � ; � ; i c t i ...............4............ -..........................�............... ... ;....-I.I.,........... � ! ! : I ; 1� ! ; ; I : : ; i i.....I......... . � ; i i i i i . ­--f-I : I ; . ........p..... � -1 .1.11"..'-- '­.I— . _,". ..... . I - -"..".1 , �...........�.......� ....�........I...................................I...."... .. .­­­....... I ­­­....�...... : I ! ! . . / .......................... : I � ! f I � : f _ti_....=_4, ---- .....................---,-,---,..-. I ;i i ! ; : ; i "'I.-.1-..." , '/ ./4//'/// I ,, ; I I ....1.1-11411 ".. __ ; .- '' .... .... - : "T... -__... I ; ./ / ./ / �/..���e/�`��"""/-`��"`�`/-"/`*`�-"/"��`�"`�"`/"`��"�� " 'z"11A 1' ../;;1'1V :,:.;1 '///1///'�//_ 11, *�'/ ; '_� F/�//' &Z- ...... 'Z.,Z' 7� ................-1... . I /.//'/ /': '' ".7" Z/ Z7 . / 70 _/ �//'��z : 0 ,/. i /I Z/ . / /I ....1.111-11.0 I i i .. ... I ". "I'll I 1-11 I I Z./ 17__ -_...._ -....-.'.'_.'_.'...._1 ..///�/2 .............I......... .. ... ...............I...........,...................­­ � i ' ""--,,--*, __ i : i = � .: ___-__ __ ­­­ - i 1 1 I4DX6 ; ) __ : : i : I i : : :; 4 i : i ! ­-� : ! I : : ! : : . I I: i i I ;i / . i 11 : T . . � i I I �";' ''t : : i .. � : i 1: : ; ,// i 11 i I ! t ; 1 i : ; I . . - , " :1 I .i 4-- ­­......' I i ; . 11 � ;0/ � : i : i _ : ; i : i ; . ii ! i : : : i i i I it I;;;;, "Ill, U/0 : :1 � : ;: p : � - �I H i : e t i : : I : : ; � - :; i � ; i I �, , i : i i I : ; . : . :i I ; i i , : h : ;i 11 :i : - i i : . ,"!�"" �' i : i . � i :; : . ; : r i� i t i ! , I I i r i i I ; / i . i . I : 1: i 1 i ! --,--x I '? 'N . i I : i: : i : ­­�. I� ; I.. . �' : - ...............­....*... ...................*** * : I...._..*.'.__...... ........................... i ir : -- i ! ! . 1: I 1: : � ---­1 -........... - .:�:...........�... �...1 i"­­ __--,-""'-"'; : . : � 11 ; '­' -_­j � ; : ! z . : ; �i :. I , . . : �'�'."' _� . I 1.I.-I.........�........i .."....-I....... ....... ............. :: ­......­­.................� ..............� .. . . ......4 .................i�............. . , � 1"" ......-I...........I....I...........1:� -...I.......................... 1. ...�"........................= ! . ! i ; ! ; : ;; i : 4 : : !,,,',/ . . .... .......... .' : i 1�--------�­-_- ­ -� �-...­ i -1...4 2 11 1 � : ! 1: ; i� : 1 i 111 15� 1��SEE NOTES H ; . .i ­'_­_"" I ! ; ; .i ; ' i : ;z I i ; 1 : ! . ,: i; : ! I ' . I / I : I i i ; " r . 1 . .. ... ... . . '­..:'..........I....�............................. i- ..:.:.................�:............... ' ' i "*......** i I - ...I ", . ­­_ � ­ � .­­.....".................I.....:...pll�....I.......� ....I.........................�............. ........ .­­.'.......- : . : " : : i : i r i ; I : ............ __........................---."------- -_A-------- ...........­­....... ­ I....,... �......I.........................,� . : :; . .......111.1........I.......­ ­ ..It � . ........- ...-.--z- ; i . ! . : ..........-.......� I--,.................mi�...................... �............................................. i ... ....._______.­_.P� I ... I ...' � _'­­­ ­­.. ­ � i : � ! r i i : ; ; i : : : i \ :; I . 11 'fi,; i � i i , ; : i / i � ; ; : i ; i : ; ; i . ! : I � ; i � I ; ! ; i ! , : ; : i \/ i 1 4 ; i i ; i ! I ; I 1 i I i ; i i I � I i : i ; i i ; ! i ; : ; ; ; i ; : : : : : I i i I i i i ; ; � � I ! : ! ! : I ; . : i " i ! ; L_ i ; i . I : I . i i : : ; I : r i i I i I : : r ! ! ­­- I : ; : i ` . . : r : : I : : i i i : ! -_ __�_------_____�_ . ; . : I ; i - __ I ! : � � ; ; i : i ; : I ![----,-"* -_ ! - ... =..__..__.____'.'_ r. � i i ; - . I : r I : i . p ;: i IV � i E'..o'=I..........I-------i I ; : i i I (60) . ; :1 ----------if - ; I REAK �X� : i � '­....Y i i i � i ; I I : I i""", \ : ; i I I : � I i i : i . i ; 1 1 i i i ;: �..... 1 (250) i I i i RTU-�2 I (60) i i -�i (00) i ! ": I . : i i : : . : ! . ; ;i i -4 i I : ;i i ; . i i ! i I ; ; Ill ACOUSTIC, LININC? ! I _..............................._..._1 - - : i - - --- ________ : : i i (D: ; : I ;: i ; : i i t i : i i ! ; : I I ! i I : I . :1 i ir I . . I ' � " . . : I i i :. i ... ... - - ...I.........,�.............., j-....­­­­..... ,i I..". I It. I[/ I ___'. , , . �.......­­......... _ I ! i : I RTU_5 :i i / z Z_... ......r ._/--A I ' il i I . I­­­­­­.I...I.".. ......... ................11.................................I— ­­­ .1.....-J-................ -__ T-F. .....L..................I-------- I .1.1......I...... .... I I it :� :! . ... I ..1-111". . .1...- ­­ ; , .:� . �/.! : t __ ---'"" : . " - : . W Z z" / /�/� - ' Z, -.. . r F_J ; ............... Z "��:' '�2/.­ -, ZIT i...... ;4 K11''I , , i .I:��r 1 ElIZZ.Z., W. ZJ I ; 1* NO : I !; 7...** I 7//�ZZ/////// '.�./'/_'/"/`_`_`_ 1�21 I ; �.//// / Z* . Z' ......................... Z//11� /� I -...- 1 4 -].................... 77 i .-��// . i A : '��/ ;% i 4 ' (.......//-/,/,I/I/ ; ! " ` '�/'/ �-'.� / * '* .,:/ ..�. ..: 1i : : : ........_ ; , . ; t � t =////i "''Z"..'*.../.*Z/""-"/-"-"`-""' i FZZ 7Z. ...Zz)._Y�Z � zz z ; 7Z" 7, : I ...// ...... �.ZZ. ......-------- ...........­.... �//'/*.`...Z/..' _.Z"/"`Z`­�"" , �Z� r7/ : : ; i ; : :� , 1 . : i i ; . i "" i . I i 1 : :.... : ; : : : i - �1 : T I �� _/'z , :i 7 . i - ..:. . . . ;: ! � ! : I ; : I If : . :i i ; r ! _. I i I I i ! i . :I ; ; : : ; ­­.!... ..............�................� ....I...I—, : ; : :, PROJECT i : . ;, I ..� . t. .i.......­­-­-­­--- i..... . ...� I .,....�............... ­ �......I..........................;­_..__.­....._.­_.-.----.-.. i 1_!_--N�_.__!i :_-.-- I; : : 22 / ; ; i i ; ; _____.'_.___ ----. I i........................�........__ ; � ; : : 1: : I....-1111"I...­�...1. ......� - -, I ­_­........... � '� : i 1 ! fl !I _'J"_........� .... / ;: �i - -��.......!..I.... 1. ­­­ ............... . ' ; ! i.I. .....I'll .- "' AL!....-E' I '� _':......�:_It...../.... .. .. . � 11 1 i . . I I :; 4 : VIP ! 14�12 q � : :; 1 . , X12 V. . Ll.......................... .... ; r ; --'---7---"----'-- 1 : -.--. --.--­ i I ; ; r i : : f . ; ; : i K i : -1 I : 1 1 :i4x12 1 � ; i I I t : : t ; : : : i i: $ ! ! : i : \ , . . ; : : ; . i i 1: : . !��415xI2 " , _1 ii : : I i i . ; p : : i 11 . :� r - ; : ; : : : . I ; : : - . ; 4 ; : : ; i ; 15XI.2 Ill 1 � I _/_ - " I/ ­ _ � i 11 I : ; ; ! I F : - - - _:_ - -22 , : ! : i : r ; ?X5 12xb t - � / :: : , �'_ -12 -124 / 1 I �__ 4�- - - ; - - - - 11 NA X12 �' - - 11 - i _ _\� _ _ i ,� : / i . PPI PP()Tn , .;- - - - - - - : ! ; if :i : _V i f : - - - - - - - - - -"', ' - 1, I , I I i- " F_ ; I I I: � 2 '�' / i ! . I. ...­ �� ; I /. 1: / i I i / / i 1 - - - _/� ­ - - - - - - � , - - - - - - I : i / . / - -1 . -I i _ / . 1 /i : I. � : - - - i7. i � , ; I ! ; V . & 0 � �' _111 . _ .. . ; . i p . ; r STONY BROOK . : . + . i i : '.�..........-­=.......,...]4......... i i : : i i I � /Ii i : ; - . ; . : i I . z i I : : / :i / i * ' - � i ; ; i \ / : / ! ! .. 1 , .. : ;: I ! ; ! I ; . ; / 1: / / . ; ' ........�....................................it : . .; ­...**' 1; ; : I . ; ; I / i i : !I . \ i : ; : ; i ; � : : . Ill A( All� __ .. 1-,z--.,.=, --- -=................, -,'_.'...-]1'_'.__._' .? :...j; ­ )/ . .........1. 11".."'.- . I / . I�_7-...----- : . /I ! : : * ;' . i [ . I : I 11�--------��-==�..'�'.'��..... � �'_ I - - ..-..-.,: - , i * 1AB ' .;**' 0" ��... ...................... ........., 1p�.�-;._.� =_ I. I ; ! I; I ; .I . I ;! - ______-/ � . i _�// '-,, " I ! ...", i ; 6'� -- . ­ _'___...................L.I.,......../I --------.-_____.___ .. ­­ �' r : , : 1 " i 1, , I I____'..' _..........­.' , ,�� __-­­_�/'-­_-_­ _.._______'__'___ -----­-­­- - i : i­� i; i ...... : . : ' I 1; : i :; 7� ��_______­ - I : I_---- I i ; I I : I ; i . z - , : I ; i . i : r : / i : I . i : : . i : � J � : '! : I i : X I : z : . ; i i ,*-"*,-*** ____ i MEDICAL : : . ;__ 4 1� . / : I...... / : : ­== -12 , 1. ---* ' -.--......___ . I / I ; . 1-1 :: - ...T,... - 1 ; � CAFE I ,. .' ..". - I :0105TIC I - � i i z ; L i ININ6, � 01, . : __.­ - -1 : W'", . �/il i i i �� !.'�_-..�......../ '*****'**"**''! " " X I �;.' 1.11-,"", . ; Z �! i : i : 11 i 11 : 12X5 --,-;­' - : : ; i r; r ! : I : 111.1.11, :'; : 1; i : : :: i - : i :: ; :1 . ; L__1: i ; i /� 1 !! �� -_J / 1 1 " I VD, I i ! i i . :: -_J ; ; ; i i i - I �: : - A 11 i I : -_ .....-J,....;; ....] :..........I............''.i------....­�.....- ­ ./11 VV � I J ; i �v : W L_ 1 .'.'7".' ................. ............-......-..............".11-1....................;................... , - -­.'; : : CK UP.......­.. VV � : (�s 5) i 10095 MAIN ROAD , ; ' ­�_..............­�..........: . ; : I ; :� : ; i : ; : : : . / ; : :; ; ; ; I :: . i I . : . I . ; i ;I 1. i I ; i; \"\,\\ 11 , :­ ­..".­ . i 1 . . :; : "....'.. ....__- I I i T, : I : ; ::1,lif : '�11 I�; 120 I ­­...........­I. . 1-1.11.1.. I : .11�..................;111.1....... .I . :i -_ I I ! ! ;; : 11......_.�'. .1"I �-­ ......... .". .1 ........11.1.1...� . :; ,: -­­­ ..................................:­­_.....11............. ............I............i ...................... ...................I.........­..�;1.1-11- I 1. ­-1 - ­­ .. . ­­ . .11...........­­­­...� .11 :­­..........___._......­_­....... ;......................................... 1 1 ; ;; : ; : I i :: 4 � .........* . ; I . .. 127 i . , i : - I ­­­­ � ;; ' � __ ;: VV i: I : : � :; 1. K_ I : i 1. ,; : : T: i i : r: : :.� 1, i : : i.:)u 4; : ;: . ; . �: : 1 __J . ; ; ;: t I ; i 11'1�'A X (50) i : ;: I : . . 1-1 :; :. .; , r: : " I ; - 11 _ ; :: .... ­ ! ; r . i i :: : . ! : . : . ; . i; . ir . i ' i ; : i : / � �/ i :� I : I ; : �; V. D 1: ! ; �� i , I ; ; : 1; ; ;: i ; : i :: : ;. i I ; ; i : : r i ,: : : ; I ; I i i .. : :. i : i I t : � 9' '/1.1 1: : i ; " i 4 i . i :: I ; i : - I : i I I i :. : . i : i i : z : ; � I I :: ! i ] : � I A. ! . : I .....:ill.. . ­'.� ; � I : ....­­ �/)' : � I i . I-—...............4 . . : : : ; ;: ! ; � i i ; .....1.'.'."._"_'-'.'_'.....=.......i.......�.........: 1 1 i : M /. _'YN I I A : I . ......... ...... .. ..... .............V, ' I '� . : :: : i I : i I I / : : 1: ; � i i ; ; . . : ! : : ; : . i :� :' : ; : i -*** i ! t i I ! ; : ; . ; I .................I:. / : : / TH EX '.7i . // : i i : I 1 r/ � .- **,**1* ROO / �J. ; .. : � ,. ;...................=..'...... ..­..__'­_............ .... ...... _'_ ­_­�­ ­..-I .....1.1.1-.......�........1................ .........I.......... ......................­­.................................. ........I.-....11.........I...... : I " ....................... ­......I.....I....... .: .....11-1. : ; i * :� it i I i ­­ I . I : : � ................... ... :; . i .......-�.........11.1i .....!.1---I........... --_11 ... ,�.........I..... �............................ ­____­�........................ .1-1------- : ..... i i I i . i ..............� �____-_ - i ' j i . . 1 1 , .....1 . ii---...�............I....1: -'4-----.--- _.___ i : i .­­­ i : ' r I/ 1 1 2 33 i I �i : -........_ - I 11.......- i /I...-.:: ii ; f� - ; i 4/1 � I...........____X__..__. / DRAWING TITLE 1 ; I : : : . . I..........­­/.---__-__ : i .. ; � ! . i i . � v : r I ......j ! i : r . ;; i ,. ; �. i : : i : : : i : 1; i ; : . : .........­_*...*­ !1 . I 1! i : : i I I I i � . i : i i r :; : :: _L ! '"" ' ­ : : : . r ;.��7 ,; ! / 1: i . : :; i . ; I : i : i ; : ,; t . . : :: i , i I /I ;; ! . i ; : ! i ; ; : : : i; : i :: !, i : :; ; ! :: ;: ; ; ; ; i . i ; : ;: ; i t : I �' 5 i ; i I :: . i / i ; :; : ; i i i s i I : . i i z I. i : : . ; ; : ;: . r; z ; ; ; : : ; I I ; , : : ;; : , . . ;; :1 . � , /" r ; r : ! : I : i .' . : i; ;; . :: ! I I I ; . �: I : ; 11 (70) /� i i ! ; I : ­.. I I ; I ; : . : 7 . ; I I : I I ; 1"�/-11. / ; ; : T : I �/' ,15 i V � ;; 1 i i ! �'� : (4-M) i(250) / 0) i ��'­ (100) (70) : (70) : ('10) I : i i I : 11 i 1; ; ; i � ; . !T i ; i :1 ; : i �' it i I i 1. / I !1 ; .........................;.....t-'..........�........­.";I-.­.........-I.....4 ­ - I . ........,..................�..... i......� .1/ ; : i ,� r ; s 1: ! / ;; I i ; . 1, . t . ! T : ;; 51 I : : T ; . 4 ! I : I ; I : ; i A . . I I I 1: /)� : . ! i i . i : ; T : ; : : :. . ; ;; i ; i :r ; ! i : . i i . :� p ; 1 i I : '; :: ; ; : i I I­­­­­. ­­­­-­­­, : i �/.' i ;i T ; : I i : ; : i i L....__*.....................� ...�..... . i : . : : i : 1 i '�,'.."'.�...='.'.'_­ _._'-=.1..........�....�....:1 I.....*`***....********* * ' ' ; /1' , . ; ..=..........�=......... ! ! : i ; . . ..... ,__....,'� -�­_­-­­ I-'I""..",...........I -.1.........I === � I : z ; - _­ i � ,­­­.....�.......-........ � ***,*,***,* .� ;; z .___ � ===.. - ­........-......................................... ...� = ; i ; ; : . I : .i .. ..­­..­� .. ­......' I '; !�...(60) ..��................_-1.11-1-1- 1�.....=,.��.=i"..'�,.=....,...,.,..,= . . I 11.1111.1.1.1"..'....I.......... I : ! ­ __. ­­ , i ! .. ; : i ; : : ; : ! . I : I : i : /. . . -------.r........................ � *I--- i . . I . 1: : i ! : i � : : ..................11.......... _­__­ . : . . i : r ; - ' ' '***' : I : : : . : MECHANICAL PLAN : :. ; . ; : , - = __........................ ......."I.I.-T I ­­­­­­­...1....................... __ a i i � . ... ! I i ; ; 4 I : . i : I : : : / ; ' ; i _____1...�---------___._______'- ; ; : ; : ; z ; i i : : 7 . : ; � i ; 250) : ; : :;(250) 1 : ; /��.....__ =__�-- --------------��'______[! .__ : ' ; ; ; : i i : I : i ; i ! ; I ! i : : � ..--"-- _=-,...... I ! : r : : : i ; : : : ; I : � : /// / : i : . i i ; ; : i I ; 1. : : � : �� � i i I I ! ; r : i I ; f i : - : 1 1 : i i ; i i ; : ; i : 1 ; : i i : : ; :: : : f : i : : : I : . /. ; i : ! i i ; : . : ; ; : : I : : '' r i �� : A i i /111 I ; : i ; : r : : : : i I ; ; i i i : ; i i : : : i 1: _ :_ ­­......­.. ­­­ I —....- i i : t ; ; ; : ; : . i I i '*! I : r : . -7""o, ill ; : ; I : . : . ! � / : ! : . -...­­­­­­­.....�........­. I... I—— : ; : . : : � 1 : i i I .I i r : _].......�'(.......7-7",""i.. ....� 1: I '�' I /r, : ; i i i ! i i : i . ! ; i : � . . : ! ; : i ; ' i : i i . . : i i . : : ! i ; I I 4 : I i ; : : ! I i : i i j i i : i � ; ; i 1 ; i i ! I : I i .'..7 k.. .i ; : i ; i i I : � : / . I i 1 i ; i : ii . � i i - .... -11, I ; : 111- /_.......................­_.._. -1....�......................... / i -_­­­1: � ; - : i �...­­­.....--.1-1-_............._............i...............................-­-­ 11....­ � � : r . i r � ! ! i � i .­.­__.'� :'::!*�'... '' ­­ .....­­� . . .1. . __ - - i I * ,I .....1 .111,1.11­­­­11 ­­­..............I �.....- ­­ ................. I . ........11.11.-....................�....�...... I.......­.....­­­i i I ; ; i .....I......I....­ ­ �.J....I !� . . ......�.... .. __ '....,, .. ....... _­­­ � vo ., I . _77,7',r � - Pi �/_/ 1�..............�...........- _______ i i i i ... r ­­­­� :!.1�...................... .; . ......:..7.:...= ; :� 'i- ........�.....__ ..........,........ ........­ ­.: 1L. .Z_ ; i ; ! I i * : i . ...... . ...,fl -1,1,,***,,,*,,*,"""*""',""I ...0'' ___ '' ,I , __>'; :i�. I—....... ........_ . '_._'.__. ............. I—. -. z : .- --­':$o' I t �I ,; 17 .............................r -Z'.'.. ­­..__'____'__......�_._.....--.-.--..------..-...-.....-�..I..........._ _ . .... . . -__f �k�f-....-.-.­..-.-.-.__.......... -..-."..",I......................;'­:­;_I....... "'I F" .. �_:� I�....._� : � I I ,, I .........J­­­ -:_�I 1 -.1.............. -........--f 1 ='.*.'*�*'..7:':'.'.­7......:'.'.'..'.".'.7"...­........1.........-.. .......... ........ .i: '** �I -1__,'_ .�� � i : ,7_,' , .............­ ­­.. ......................I.....�.....�................ _... .... .................. . . ��....... .. ­ - ­­ .. . ....". ­ j�imi _ �7 i .1- i : �� i ;: , - ---- -- _ . : i: ! :... __ i ; t....... . i . V�; i I i : .._.._­_­ !: � 1 j : .1 i :: : 1.1 4 i : i: r T.......I :.. ....I.I.I..'.....1.111...___­­­ � � - - ­ .... . -­­­I I I .........­­­...­ .... ........ ... "....."......­....................................... ...................I...............�........................�..................... � .................... - ".-- ­ -_ : ; :: � i ­.. ..........................�.....................................I.....I......................................................................................................................�.............................................11-......"..."....... I ...................................�.....................�...............____..__._'_......__.­..­­....................I.I--........................................'___.'................­­........__­­'__.'_._.._...­.....�...........................­...................�..............�...................�.....-..-..-.................................................... ....J ; i i : :: � i i ; I : i ; 1: I : i : .: I : SEE NOTE 2 : i SCALE ASSHOWN : BYPA65 BOX BPB_I : ; i ; : I ; ; i ; : (1525 C'FM) ; : i ; DRAWN BY I I i ARC i REFER TO DETAILS M-201 I f : : : DRAWN FOR i i I � I TET ; i I I : I : ! : : : CHECKED BY : : TET : : i : ! i : i I i I i i a i PROJECT# 20-021 : i : ! : : i i : : i i ! : i ; ; I ! ! : � : DATE -4-4---- : ; : i i ; ; ! i ; � i ; : i : � ; I ; : i 1 SHEET NO, I /_ M-1 01 / / � / I / �/ I / ' / - ' ' - I / / I . i � - i i i i i i i 'i i I i i i I . . ; : ; i i L/ I . * : , ; : � � I i i i j i j I (Di i ..; ; � ; z ; ; i ! i : i : i 7 i I ! // i i : i : ; �/ i : i : i i /I i : i : I ! ! i // : i : i __ i 1 i i ! � i .t � ; " i I I � i - : I i i i i ]ZI z X X .M -Z D ! I ! I i 1 '_� T 1 , K I - : : I : � I . i I I 1� : i ; I I i i i 7 z I " ! .. ; / i I ; \11 ';. . [�/! / � ! [A ... I iKli N r / ; J, / i I . I i 7 z ZZ;� IL J z. , I IX/1 D /_-_I' I //�C) I I �n�\, -,' . / I ..� ! : ZF 21 � i r / , i - i i N A i i (a�) ", I ,fi i . S , . i - I .'..V- 1- �I , i I, I i i Jz ! F7 i 1; i ; ' N��.' � ��. lensi I N : � I I : I I I I . 1 I ANICAL PLAN- 1/4 0 =1 11-099 SHEET 1 OF 4 - NO. REVISIONS DATE 1 ISSUED FOR REVIEW 5/12/2020 AND COORDINATION 2 95% ISSUE 5/14/2020 3 COMPLETED 5/22/2020 ® Control Package CONSTRUCTION SET SUPPLY MAIN MAIN M 7 A!r BR 4 COMPLETED 6/04/2020 SECURE FLEXIBLE DUCT TO DUCT DUCT SIZE 15 SAME AS HEMMED EDGE 5G0GOG COLLAR WITH 5.5. SCREW CLAMP SCHEDULED NECK CONNECTION AIR TERMINAL CONTROLS CONSTRUCTION SET •BYPASS/RELIEF 5 COMPLETED 6/12/2020 INSULATED FLEXIBLE DUCT OF DIFFUSER AIR FLOW AIR FLOW •ANALOG ELECTRONIC CONTROLS � •AUTOMATIC HTG/CLC CHANGEOVER PER ROTATION CONSTRUCTION SET •PRESSURE DEPENDENT RIGHT HAND CONTROLS LEFT HAND CONTROLS ADJUSTABLE ELf30W. cw=OPEN cw=CLOSE 6 ISSUED FOR PERMIT 7/07/2020 SEAL JOINTS WITH DUCT DEFLECTOR DAMPERPIVOT •ADJUSTMENTS AT THERMOSTAT CCW=CLOSE CCW=OPEN SEALANT AFTER ADJUSTMENT101 ADJUSTIN6 ROD a PIVOT CA5TIN6 BRANCH DUCT VOLUME ADJUSTABLE BYPASS DAMPER MANUAL BALANCING n� DAMPER WITH LOCK AND BOLT ,. 15ULATION DIA`MPER BRANCH DUCT DAMPER{BY OTHERS) SUPPLY DUCT 5PL I TTER DAMPER DETAILEXTEND DAMPER — OPERATOR THRU (TYPICAL FOR ALL BRANCH DUCTS) PRIMARY AIR AIR TO SPACE INSULATION BRANCH VOLUME DAMPER DETAIL ----- - - ----- — —— — — — (TYPICAL FOR ALL BRANCH DUCTS, NOT TO SCALE) MIN 3 X DIAMETER MEP-4802(SEE WIRING DETAIL BELOW) GEILIN6 SPLINE GEILIN6 TILE SUPPLY DUCT DIVERTING DAMPER GEILIN6 DIFFUSER STE-1002 DUCT TEMP SENSOR WTH 18"WIRES GE I L I NC DIFFUSER CONNECTION DETAIL AIR FLOW 2 - 1/8" UP TO 20" WIDE MEP-4802 3 – 1/4" OVER 20" WIDE CONTROLLER-ACTUATOR (NOT TO SCALE) 4-1/2" NOTE: VANES SHALL BE OF DOUBLE METAL SWITCH 2 Alk � 3 a RH CONTROLS-CW CONSTRUCTION 4 SHALL BE IN o g LH CONTROLS-CCW SEPARATE FRAME BOLTED, RIVITED d o :� MANCINI OR SPOT WELDED ELBOW. z ;' ANGLE FASTENER PLATE i o a 1'Q Q �% ARCHITECTURE SAME 6AUS-E A5 COLLAR SQUARE ELBOW DETAIL 0 1 2 mul CONSTRUCTION RETAINING ANGLE MINIMUM (NOT TO SCALE) 1/2 x 1/2 x 1/8 FASTENED IN DAMPER COLLAR TO BE \ 222 Middle Country Rd. Suite 314 FIELD TO HALL COLLAR ONLY SAME GAUGE A5 DUCT —— ——— —————-J L— I _— Smithtown, NY 11787 5" OG ————— — ———————�v� PRIMARY VOLTAGE,10 T: 631-979-0104 I (� pizov pzosv 0240V10277V —— I N L2 L2 N THERMOSTAT L L1 Lt L F: 631-979-3445 -- I I - CTE info@manciniarchitecture.com T GOLLAR/DUG'1' I I NOTE:SELECT � w GRNO GROUND CONNECTION PER SMAGNA% " SEQUENCE 1 (SEtti) d DUCT HE16HT I I IN°SYSTEM°MENU d 6 MINIMUM ( I I I o S OPTIONAL CLASS-2 I I OPTIONAL TRANSFORMER I I DISCONNECT 24VAC 40 VA ❑NONE ❑BYANEMOSTAT I I ❑SPST(L-N) I I I I I I I I I ❑BYOTHERS I I 0DPST(L1-L2) ( I NOTE: ACCESS DOOR I AIR FLOW I I I FIRE DAMPER TO BE 6 6 FUSIBLE LINK 1/D 14 MIN L�__— —_____= —t— N.Y.G. BSA APPROVED PER �55/4 D Tan-gel Engineering Associates, P.C. SECTIONS R3 B--I CALENDER NO. 100-63 3' – Oil – _ ———— ——— Consulting Engineers _ VD FACTORY WIRING UP TO 1800 FPM - USE TYPE "B" FV. –— —– FIELD WIRING REFER TO ANEMOSTAT"CONTROLS MANUAL"(CM-1)FOR UP TO 2500 FPM – USE TYPE "G" FD. D ADJUSTMENT&TROUBLESHOOTING PROCEDURES. 285 Middle Country Road,Suite 208 Smithtown,NY 11787 FIRE DAMPER DETAIL DWG #: BR-A-5202.1 JOB NAME: Phone:631.750.2800 NESTED F I TT I NC DETAIL Fax:631.750.2744 (NOT TO SCALE) (NOT TO SCALE) SUBMITTED BY: REV: B neering.com DATE: DATE: 9-27-2017 tangelengi WWW.ANEMOSTAT-HVAC.COM COPYRIGHT 2017-ALL RIGHTS RESERVED This drawinq has been prepared for the indicated project and is an instrument of service copyrighted by Mancini Architecture PLLC. This drawing may not be copied or used, in whole or in part, by any party without ROOF GAP the expressed written consent of Mancini Architecture PLLC. Infringements or any use STRUCTURAL of this drawing for any other purposes will be STEEL BEAM prosecuted to the full extend of criminal law HEAVY DUTY FLA5HIN6 CLAMP ROOFING y, � HANGER ROD KEY PLAN ��pF PJEE�j�- EYE SOCKET DUCT THRU ROOF1 4 ' PROVIDE WEATHERPROOF ROOF GAP ATTACHMENT TO STEEL BEAM �� 6 (NOT TO SCALE) (✓'-O") �A 6 1 8 4.p c �OF�SS10'`'C� 1/4"4) STEEL HANGER 80175 (4 REGUIRED) BAGKDRAFT DAMPER G CLAMP SIMILAR TO CARPENTER PATTERSON TYPICAL V.A.V. BOX PROJECT VIBRATION ISOLATOR STONY BROOK (4 REOUIRED) �-� HOOK HANGER OVER D15_HARE D LINING MEDICAL E REINFORGIN6 ROD OR ATTENUATOR 10095 MAIN ROAD STEEL TRUSS MATTITUCK, NY 11952 HANGER ROD �( TYPICAL SUPPLY DUCT EXHAUST GRILLE `j GEILIN6 TILE DRAWING TITLE HAN61N6 DETAIL MECHANICAL DETAILS FOR DUCTS, OVER HAN61N6 DETAIL 48" WIDE FOR DUCTS LESS THAN 48" WIDE GE I L I NC EXHAUST FAN DETAIL 5TRAI CHT LENGTH OF (NOT TO SCALE) INLET DUCT TOM FIVE SCALE AS SHOWN DUCT SIZE RANGER SIZE MAX. SPACING TIMES BOX INLET SIZE DRAWN BY ARC UP TO 25 50. FT. I" x 1/16" 8' - O" DRAWN FOR TET /��✓ �J CHECKED BY TET 2 TO 8 50. FT. I" x I/16" 51 - 011 PROJECT# 20-021 OVER 85 50. FT. I" x 1/8" 41 - 011 DATE -4--/---- SHEET NO. TYP I GAL BYPASS BOX DETA I L DUCT HANG INC DETAIL AND SCHEDULE OF SUPPORTS (NOT TO SCALE) (NOT TO SCALE) M-201 SHEET 2 OF 4 NO. REVISIONS DATE 1 ISSUED FOR REVIEW 5/12/2020 AND COORDINATION 2 95% ISSUE 5/14/2020 CAS F I RE:D ROOFTOP AC UNIT 3 COMPLETED 5/22/2020 CONSTRUCTION SET INDOOR FAN AIR CONDITIONING DATA NATURAL 6AS HEATING DATA ELECTRICAL DATA 4 COMPLETED 6/04/2020 CONSTRUCTION SET CAPACITY ENT INDOOR LV& INDOOR OUTDOOR AIR 6A5 INPUT &ROSS 6A5 PRESS AFUE t(� 5 COMPLETED 6/12/2020 O AIR AIR CONDITIONS AGA OUTPUT IN H2O 44z cpl� ? CONSTRUCTION SET TAO NO. SERVINGS 0.� � Ir- ci 9 TRANE MODEL# 6 ISSUED FOR PERMIT 7/07/2020 z z 4 N N IL ISL ISL IL IL IL l0 �p lA 2 Mla z XX z O Q Q v w � x �- � � w RTU-I INTERIOR 1675 05 1.0 58.08 44.55 12.0 50 67 55.98 55.96 89 76 150/105 1215/65.05 4.5- 14 81 206 5 60 29 40 410A 522 797 Y500606 RTU-2 PERIMETER 2055 05 1.0 60.25 50.11 12.0 50 67 51.57 57.57 69 76 150/105 1215/65.05 45- 14 61 206 5 60 29 40 410A 522 797 Y900606 WAITING RTU-5 ROOM 1725 05 1.0 56.59 45.12 12.060 67 56.26 56.26 89 76 150/105 1215/65.05 45- 14 61 206 5 60 29 40 410A 522 797 YSCO6061 100 NOTES: I. NEW ROOFTOP AG UNITS SHALL BE FURNISHED AND INSTALLED BY LANDLORD. 2. NEW ROOF CURBS FOR AG UNIT SHALL BE FIRNISHED AND INSTALLED BY LANDLORD. FAN SCHEDULE El EGTRIGAL DATA MANC11\4 I BYPASS BOX 50HEDULE ARCHITECTURE Mp N N CFM U I CONSTRUCTION c W a UNIT NO. INLET SIZE MIN. MANUFACTURER / MODEL # < 'f=RVICE TYPE 222 Middle Country Rd. Suite 314 z !t- VOLTS RANGE SET SET (IN' K&J Smithtown, NY 11787 v �-- HP PH/Hz RPM 50NE5 T: 631-979-0104 BPB-I 12-D 450-1400 1525 0.10 ANEM05TAT RME UJ F: 631-979-3445 O z � m 1) z 4 J NOTES: info@manciniarchitecture.com I. FOR MAX GFM 5ETTIN6, SEE FLOOR PLAN DRAWING. EF-I JANITORS CLOSET 124 GEILIN6 MOUNTED - &REENHECK SP-AP-0511WL 2. ALL CONTROLS, RELAYS, WIRING AND M15CELLANEOUS DEVICES SHALL BE BY THE MECHANICAL CENTRIFUGAL 80 05 17 115/1/60 561 25 - CONTROLLED BY WALL CONTRACTOR. SWITCH 5. BYPASS BOXES TO HAVE ELECTRONIC ANALOG CONTROLS. (ANEMOSTAT CONTROLS BR-A 5202, 120V GEILIN6 MOUNTED6REENHECK SP-AP-05llKL PRIMARY VOLTAGE) EF-2 I.T. 115 CENTRIFUGAL 60 0.5 17 115/1/60 661 2.5 - CONTROLLED BY WALL 4. ALL VAV BOX THERMOSTATS SHALL BE ELECTRONIC, AND BY A SINGLE MANUFACTURER COMPATIBLE SWITCH WITH THE BOXES. &REENHECK 5P-AP-0511WL 5• BYPASS VARIABLE VOLUME BOXES SHALL BE DE516NATED ON PLAN. TX-I BATHROOM III GEILIN6 MOUNTED 60 05 17 115/1/60 661 25 - CONTROLLED BY WALL 6. MECHANICAL STOP BT MANUFACTURER SHALL BE FIELD ADJUSTABLE BY CONTRACTOR. y GENTRIFU6AL SWITCH GEILIN6 MOUNTED &REENHEGK 5P-AP-0511WL TX-2 BATHROOM 125 CENTRIFUGAL &0 05 17 115/1/60 661 2.5 - CONTROLLED BY WALL SWITCH Tan Engineering Associates, P.C. 6REENHECK SP-AP-051IWL Consulting Engineers TX-5 EX15TI1W& BATHROOM GEILIN6 MOUNTED GENTRIFU&AL 50 0.5 17 115/1/60 661 25 - CONTROLLED BY WALL SWITCH &REENHECK SP-AP-05I IWL 285 Middle Country Road,Suite 208 TX-4 EXISTII46 BATHROOM GEILIN6 MOUNTED 80 05 17 115/1/60 661 2.5 - CONTROLLED BY WALL Smithtown,NY 11787 CENTRIFUGAL 5WITGH Phone:6. 2 00 750.27 tangelengineering.com This drawing has been prepared for the indicated project and is an instrument of service copyrighted by Mancini Architecture PLLC. This drawing may not be copied or used, in whole or in part, by any party without the expressed written consent of Mancini Architecture PLLC. Infringements or any use of this drawing for any other purposes will be prosecuted to the full extend of criminal law OE I L I NG D I FFUSER SCHEDULE KEY PLAN OG � SELECTIONS BASED ON ANEMOSTAT PARA6ON CO E :. NECK SIZE 51ZE CFM RANGE p , n t @ 4" 4) 12"xl2" 0-50 6 � 24"x24" 50-100 SOA 66361 ,,, :.<,I, �OFSt�f'��'a 6" 24"x24" 101-175 ®�5 10,10 24"x24" 176-275 12,10 24"x24" 276-395 14" 0 24"x24" 596-555 15" 4P 24"X24" 556-615 PROJECT 0 NG NOT TO EXCEED 20 STONY BROOK * NECK VELOCITY NOT TO EXCEED 500 FPM MEDICAL 10095 MAIN ROAD MATTITUCK, NY 11952 DRAWING TITLE MECHANICAL SCHEDULES SCALE AS SHOWN DRAWN BY ARC DRAWN FOR TET CHECKED BY TET PROJECT# 20-021 DATE SHEET NO. M-401 SHEET 3 OF 4 NO. REVISIONS DATE MECHANICAL CODE NOTES(MECHANICAL SYSTEMS) 1. GENERAL 1 ISSUED FOR REVIEW 5/12/2020 1. INSPECTIONS,TESTS, REPORTS AND SIGN OFFS FOR MECHANICAL A.ALL WORK TO BE IN ACCORDANCE WITH BUILDING STANDARDS AND NEW 5. INSULATION 12.AUTOMATIC TEMPERATURE CONTROLS. J. HIGH PRESSURE CONTROL SYSTEMS SHALL BE PERFORMED AS PER ARTICLE 116. YORK STATE BUILDING CODE REQUIREMENTS. ALL UNITS INCLUDE HIGH PRESSURE CUTOUT AS STANDARD, MECHANICAL LEGEND AND COORDINATION A. ALL SUPPLY AND RETURN AIR DUCT FROM AIR HANDLERS AND AC UNITS: A. THE CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AUTOMATIC K. PHASE MONITOR B.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIVING ALL PERMITS, 2 95% ISSUE 5/14/2020 2. AS PER SECTION MC 301.7, ELECTRICAL WIRING, CON?ROLS AND APPROVALS AND TOWN OF ISLIP BUILDING DEPARTMENT FORMS;AS INTERIOR DUCTWORK SHALL BE INSULATED WITH R-6 FIBERGLASS BLANKET WITH TEMPERATURE CONTROL SYSTEM INCLUDING ALL DEVICES, INTERFACES AND PHASE MONITOR SHALL PROVIDE 100%PROTECTION FOR MOTORS AND COMPRESSORS CONNECTIONS TO EQUIPMENT AND APPLIANCES REGULATED BY THIS CODE REQUIRED FOR THE INSTALLATION AND OPERATION OF THE AIR FOIL VAPOR BARRIER. SECURED WITH PINS,ALL SEAMS SHALL BE CONTROL WIRING. AGAINST PROBLEMS CAUSED BY PHASE LOSS, PHASE IMBALANCE,AND PHASE REVERSAL. 3 COMPLETED 5/22/2020 SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. CONDITIONING SYSTEM AND FIRE ALARM MODIFICATIONS. TAPED. B. THE CONTRACTOR SHALL DESIGN THE AUTOMATIC TEMPERATURE CONTROL SYSTEM PHASE MONITOR IS EQUIPPED WITH AN LED THAT PROVIDES AN ON OR FAULT INDICATOR. t4 GATE VALVE C.ALL WORK SHALL BE COORDINATED WITH ALL TRADES PRIOR TO B. ALL EXPOSED DUCTWORK(I.E. IN MECHANICAL EQUIPMENT ROOM)SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS AND THE THERE ARE NO FIELD ADJUSTMENTS.THE MODULE WILL AUTOMATICALLY RESET FROM A CONSTRUCTION SET 3. VENTILATION SYSTEMS SHALL CONFORM TO THE REQUIREMENTS OF INSTALLATION TO AVOID CONFLICTS. INSULATED WITH RIGID BOARD, MINIMUM R-8, SECURED WITH PINS,ALL SEAMS SHALL BE AUTOMATIC TEMPERATURE CONTROL SEQUENCE. FAULT CONDITION. TAPED. C. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL SHOP DRAWINGS OF THE L..REFRIGERANT CIRCUITS X GLOBE VALVE 4 COMPLETED 6/04/2020 SECTION MC 401 THROUGH SECTION MC 407. D. SHOP DRAWINGS OF ALL EQUIPMENT AND MATERIALS, INCLUDING SHEET C. ALL PIPING SHALL BE INSULATED WITH PRE MOLDED FIBERGLASS PIPE AUTOMATIC CONTROL SYSTEM INCLUDING BUT NOT NECESSAILY LIMITED TO EACH REFRIGERANT CIRCUIT OFFER THERMAL EXPANSION VALVE AS STANDARD. SE=RVICE METAL SHOP STANDARDS, SHALL BE SUBMITTED PRIOR TO INSTALLATION INSULATION WITH FOIL VAPOR BARRIER.ALL SEAMS TO BE TAPED. DEVICES SELECTIONS,WIRING DIAGRAMS COORDINATED WITH THE SELECTED PRESSURE PORTS,AND REFRIGERANT LINE FILTER DRIERS ARE FACTORY-INSTALLED AS M PLUG VALVE CONSTRUCTION SET 4. EXHAUST SYSTEMS SHALL CONFORM TO THE REQUIREMENTS OF OF ANY EQUIPMENT OR MATERIALS AND SHALL BE COORDINATED WITH 1) DRAINS-1"THICK. EQUIPMENT, DEVICE SCHEDULE INCLUDING DEVICE TAG NUMBERS AND A SCHEDULE STANDARD.AN AREA SHALL BE PROVIDED FOR REPLACEMENT SUCTION LINE DRIERS. 6 BALL VALVE 5 COMPLETED 6/12/2020 SECTION MC 501 THROUGH SECTION 515. ALL TRADES. OF ALL DEVICES LISTING TAG NUMBER, MANUFACTURER, MODEL NUMBER AND M.GAS HEATING SECTION E. PROVIDE 3/8"SCALE AS BUILT DRAWINGS.THE CONTRACTOR WILL NOT BE D. ALL PIPE FITTINGS SHALL BE INSULATED WITH MOLDED FIBERGLASS SETPOINTS. THE HEATING SECTION SHALL HAVE A PROGRESSIVE TUBULAR HEAT EXCHANGER DESIGN I BUTTERFLY VALVE CONSTRUCTION SET 5. DUCT SYSTEMS SHALL CONFORM TO THE REQUIREMENTS OF SECTION GIVEN THIS ENGINEER'S DRAWINGS IN AUTO CAD FILE FORMAT. INSULATION WITH A PVC JACKET.ALL SEAMS SHALL BE TAPED. D. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS USING STAINLESS STEEL BURNERS AND CORROSION RESISTANT STEEL THROUGHOUT.AN u MC 601 THROUGH SECTION MC 609. F. FIRE STOP ALL PENETRATIONS IN FIRE RATED WALLS AND FLOOR SLABS AND APPLICABLE CODES, INCLUDING THE NATIONAL ELECTRICAL CODE. INDUCED DRAFT COMBUSTION BLOWER SHALL BE USED TO PULL THE COMBUSTION6 ISSUED FOR PERMIT 7/07/2020 E. PRE-INSULATED DUCT SHALL NOT BE REQUIRED TO HAVE ADDITIONAL EXTERIOR E. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL A FINAL AUTOMATIC PRODUCTS THROUGH THE FIRING TUBES.THE HEATER SHALL USE A DIRECT SPARK D�4 SOLENOID VALVE 6. REFRIGERATION REQUIREMENTS FOR MECHANICAL SYSTEMS SHALL 2. LOW PRESSURE DUCT WORK FOLLOW THE REQUIREMENTS OF SECTION MC 1101 THROUGH SECTION MC INSULATION. TEMPERATURE CONTROL SEQUENCE. IGNITION(DSI)SYSTEM. ON INITIAL CALL FOR HEAT,THE COMBUSTION BLOWER SHALL tk AUTOMATIC VALVE F. THE CONTRACTOR SHALL PROVIDE AN INSTRUCTION MANUAL AND SHALL INSTRUCT PURGE THE HEAT EXCHANGER FOR 20 SECONDS BEFORE IGNITION AFTER THREE 1109. A.ALL DUCTWORK TO BE FLANGED DUCT CONNECTOR SYSTEM SIMILAR TO 5. VIBRATION ISOLATION THE END USER HOW TO OPERATE THE SYSTEM. UNSUCCESSFUL IGNITION ATTEMPTS,THE ENTIRE HEATING SYSTEM SHALL BE LOCKED 7.AS PER MC 102.3, MECHANICAL SYSTEMS, BOTH EXISTING AND NEW,AND "DUCTMATE" PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING CONDITION IN B.ALL DUCTWORK RD A FABRICATED IN ACCORDANCE WITH LOW )OUT UNTIL MANUALLY RESET AT THE THERMOSTAT/ZONE SENSOR. UNITS SHALL BE 0 CHECK VALVE AND A. INSTALL RUBBER-IN-SHEAR ISOLATORS FOR ALL CEILING MOUNTED 13.AUTOMATIC TEMPERATURE CONTROL SEQUENCE SUITABLE FOR USE WITH NATURAL GAS OR PROPANE FIELD-INSTALLED KIT AND ALSO ACCORDANCE WITH THE ORIGINAL DESIGN AND IN A SAFE AND SANITARY ASHRAE STANDARDS AND GUIDES RECOMMENDATIONS FOR LOW EXHAUST FANS,AC UNITS,AIR HANDLERS AND CONDENSATE PUMPS SIMILAR TO V.M.C.I. COMPLY WITH THE CALIFORNIA REQUIREMENT FOR LOW NOX EMISSIONS CONDITION. PRESSURE DUCTWORK AS FOLLOWS: RHD.. A. ALL ROOFTOP AIR CONDITIONING UNITS SHALL HAVE HEAT/COOL 24 HOUR/?DAY (GAS/ELECTRIC ONLY). 4 THERMOMETER WITH WELL a)SUPPLY DOWNSTREAM OF AC UNITS AND DX AIR HANDLERS: B. ALL EXTERIOR EXHAUST FANS SHALL BE MOUNTED ON ROOF CURBS PROGRAMMABLE THERMOSTATS WITH AUTOMATIC CHANGEOVER. N.POWERED OR UNPOWERED CONVENIENCE OUTLET A ND 9 OF THE NEW YORK STATE MECHANICAL CODE. DOWNSTREAM INCLUSIVE OF ALL TAPS WITHIN TEN FEET. MINIMUM 24 HEATING SYSTEMS WHEN APPLICABLE, SHALL COMPLY WITH CHAPTERS 6, 8 LOW PRESSURE CONSTRUCTION ACOUSTIC LINING TEN FEET PROVIDED BY FAN MANUFACTURER. CURB SHALL ACCOUNT FOR ROOF PITCH. B. ALL THERMOSTATS SHALL HAVE BUILT IN FREEZE PROTECTION. THIS IS A GFCI, 120V/15AMP, 2 PLUG, CONVENIENCE OUTLET, EITHER POWERED OR PRESSURE GAUGE WITH AND C. THE TOILET EXHAUST FANS AND JANITORS CLOSET EXHAUST FAN SHALL BE UNPOWERED. WHEN THE CONVENIENCE OUTLET IS POWERED,A SERVICE RECEPTACLE COCK AND SNUBBER GAUGE. CONTROLLED BY A LOCAL,WALL MOUNTED MANUAL SWITCH. DISCONNECT WILL BE AVAILABLE.THE CONVENIENCE OUTLET IS POWERED FROM THE LINE 9. FIRE DAMPERS, SMOKE DAMPERS OR COMBINED FIRE AND SMOKE b)RETURN: LOW PRESSURE CONSTRUCTIONACOUSTIC LINING TEN 6. MOTOR CONTROLLERS D. THE I.T. ROOM EXHAUST FAN (EF-2)SHALL BE CONTROLLED BY A WALL MOUNTED SIDE OF THE DISCONNECT OR CIRCUIT BREAKER,AND THEREFORE WILL NOT BE -III- UNION DAMPERS SHALL COMPLY TO THE REQUIREMENTS OF SECTION MC 401.5.1 FEET DOWNSTREAM INCLUSIVE OF ALL TAPSS WITHIN TEN FEET. MINIMUM THERMOSTAT THAT SHALL ENERGIZE EF-2 UPON A RISE IN TEMERATURE ABOVE AN AFFECTED BY THE POSITION OF THE DISCONNECT OR CIRCUIT BREAKER.THIS OPTION CAN 24 GAUGE. A. FOR EACH MOTOR MORE THAN 1/2 HP, FURNISH AN AUTOMATIC MAGNETIC ADJUSTABLE PREDETERMINED SETPOINT. ONLY BE ORDERED WHEN THE THROUGH THE BASE ELECTRICAL WITH EITHER THE 10.AS PER SECTION MC 106.6, CONSTRUCTION DOCUMENTS FOR HEATING c) EXHAUST DUCT: LOW PRESSURE CONSTRUCTION MINIMUM 24 X-LINE STARTER, WITH TWO(2)N.O.AND TWO(2)N.C.WITH CONTROL E. BYPASS BOXES SHALL BE CONTROLLED BY A WALL MOUNTED HEAT/COOL DISCONNECT SWITCH OR CIRCUIT BREAKER OPTION IS ORDERED. -1110- FLOW DIRECTION SYSTEMS SHALL INCLUDE THE TEMPERATURE TO BE MAINTAINED FOR EVERY GAUGE. BRANCH DUCTWORK FROM VERTICAL RISER MAY BE FLEXIBLE TRANSFORMER,THERMAL OVERLOAD SWITCH WITH PILOT LIGHT AND THERMOSTAT WITH AUTOMATIC CHANGEOVER. TOOM AND THE OUTPUT CAPACITY IN BTU PER HOUR OF THE CENTRAL METAL DUCT TO TOILET EXHAUST FAN. CLAMP DUCT TO TXF -- H-O-A SWITCH. IN EXPOSED LOCATION, SWITCH SHALL BE FLUSH O.THROUGH THE BASE ELECTRICAL ACCESS EXISTING PIPING HEATING SOURCE. CONNECTION AND SEAL WITH SCOTCH ECM-90. MOUNTED TYPE WITH STAINLESS STEEL PLATE14ROOFTOP GAS FIRED AC UNITS(RTU-1 2 3) AN ELECTRICAL SERVICE ENTRANCE SHALL BE PROVIDED ALLOWING ELECTRICAL ACCESS r� d)OUTSIDE AIR DUCTWORK: . . , ,24 GAUGE LOW PRESSURE CONSTRUCTION. FOR BOTH CONTROL AND MAIN POWER CONNECTIONS INSIDE THE CURB AND THROUGH -CD- CONDENSATE DRAIN 11.AS PER SECTION MC 301.2, HEATING,VENTILIZATION AND C. MINIMUM DUCT SHEET METAL GAUGE: 24 GAUGE. THE BASE OF THE UNIT.OPTION WILL ALLOW FOR FIELD INSTALLATION OF LIQUID-TIGHT -pa- PUMP DISCHARGE AIR-CONDITIONING SYSTEMS OF ALL STRUCTURES SHALL BE DESIGNED AND D. ALL DUCTWORK SHALL BE SUPPORTED IN ACCORDANCE WITH DUCT B. FOR EACH MOTOR LESS THAN 1/2 HP, FURNISH E MANUAL TYPE A. GENERAL INSTALLED FOR EFFICIENT UTILIZATION OF ENERGY IN ACCORDANCE WITH OVERLOAD SWITCH WITH PILOT LIGHT.ALL EXTERIOR ROOF TYPE THE UNITS SHALL BE CONVERTIBLE AIRFLOW.THE OPERATING RANGE SHALL BE BETWEEN CONDUIT AND AN EXTERNAL FIELD-INSTALLED DISCONNECT SWITCH. HANGING DETAIL AS SHOWN ON DRAWING AND SUPPORTING BY THE 115°F AND 0°F IN COOLING AS STANDARD FROM THE FACTORY FOR UNITS WITH P. THROUGH THE BASE ELECTRICAL WITH DISCONNECT SWITCH -MU- MAKEUP WATER IV BUILDING STRUCTURE, IF ACCEPTABLE TO"EHE BUILDING MANAGEMENT. EXHAUST FANS SHALL HAVE LOCAL WATERPROOF DISCONNECT TOGGLE MICROPROCESSOR CONTROLS. OPERATING RANGE FOR UNITS WITH THIS 3-POLE, MOLDED CASE, DISCONNECT SWITCH WITH PROVISIONS FOR THROUGH THE NATURAL GAS THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE. mIANCINI SWITCH WITH PILOT LIGHT. -C�- E. ALL DUCTWORK DIMENSIONS SHOWN ARE INSIDE CLEAR DIMENSIONS. C. ACCU-1 AND ACCU-2, SHALL HAVE A LOCAL DISCONNECT WATERPROOF ELECTROMECHANICAL CONTROLS SHALL BE BETWEEN 115°F AND 40°F. COOLING BASE ELECTRICAL CONNECTIONS ARE AVAILABLE. THE DISCONNECT SWITCH WILL BE 12.AS PER SECTION MC 312, HEATING AND COOLING SYSTEM DESIGN LOADS F. PROVIDE FLEXIBLE CONNECTIONS AT ALL DUCT CONNECTIONS TO AC DISCONNECT SWITCHES AS SPECIFIED PERFORMANCE SHALL BE RATED IN ACCORDANCE WITH ARI TESTING PROCEDURES.ALL INSTALLED IN THE UNIT IN A WATER TIGHT ENCLOSURE - SUC- REFERIGERANT PIPE (SUCTION) FOR THE PURPOSE OF SIZING SYSTEMS,APPLIANCES AND EQUIPMENT SHALL UNITS AND FANS. WITH ACCESS THROUGH A SWINGING DOOR.WIRING WILL BE PROVIDED FROM THE SWITCH BE DETERMINED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED IN THED ALL AC UNITS SHALL HAVE A FIELD INSTALLED LOCAL DISCONNECT SWITCH EXCEPT UNITS SHALL BE FACTORY ASSEMBLED, INTERNALLY WIRED, FULLY CHARGED WITH R-410A, G. ALL NEW SUPPLY AND RETURN AIR DUCTWORK SEAMS SHALL BE SEALED WHERE EQUIPMENT IS SUPPLIED WITH AN APPROVED, FACTORY INSTALLED, AND 100 PERCENT RUN TESTED TO CHECK COOLING OPERATION, FAN AND BLOWER TO THE UNIT HIGH VOLTAGE TERMINAL BLOCK.THE SWITCH WILL BE UL/CSA AGENCY - LIQ- REFRIGERANT PIPING (LIQUID) ARCHITECTURE , . , . ASHRAE HANDBOOK OF FUNDAMENTALS. WITH SCOTCH ECM-900 SEALANT, OR EQUAL AROUND THE ENTIRE ACCESSIBLEINTEGRAL DISCONNECT SWITCHROTATIONAND CONTROL SEQUENCE BEFORE LEAVING THE FACTORYWIRING INTERNAL RECOGNIZED.NOTE:THE DISCONNECT SWITCH WILL BE SIZED PER NEC AND UL PERIMETER OF THE DUCT SEAMS AND AT ALL SOLID TO FLEXIBLE DUCT GUIDELINES BUT WILL NOT BE USED IN PLACE OF CONSTRUCTION 13. SYSTEM CONTROLS SHALL COMPLY WITH THE REQUIREMENTS OF CONNECTIONS TO REGISTERS AND CEILING DIFFUSERS.ALL DUCT SEALING TO THE UNIT SHALL BE COLORED AND NUMBERED FOR SIMPLIFIED IDENTIFICATION. UNITS -- - mul SECTION MC 405. MECHANICAL VENTILATION SYSTEMS SHALL BE PROVIDED 7. ELECTRICAL APPARATUS SHALL BE CULUS LISTED AND LABELED, CLASSIFIED IN ACCORDANCE FOR CENTRAL UNIT Q ERC E OF OP PROTECTION. - EXISTING DUCT SHALL COMPLY WITH ASHRAE 90.1-2013. COOLING AIR CONDITIONERS. Q.SEQUENCE OF OPERATION(IF APPLIED IN A SINGLE-ZONE CONSTANT-VOLUME SYSTEM NEW DUCT 222 Middle Country Rd. Suite 314 WITH MANUAL OR AUTOMATIC CONTROLS THAT WILL OPERATE SUCH H. ALL EXHAUST DUCTWORK SHALL BE SEALED WITH SCOTCH ECM-900 A. PROVIDE ELECTRICAL APPARATUS AND IN ACCORDANCE WITH THE B. CASING OR A CHANGEOVER BYPASS SYSTEM) SYSTEMS WHENEVER THE SPACES ARE OCCUPIED. SEALANT, OR EQUAL AROUND THE ENTIRE PERIMETER OF THE DUCT SEAMS SINGLE-ZONE CONSTANT-VOLUME SYSTEM Smithtown, NY 11787 CONTRACT DOCUMENTS TO INCLUDE MOTOR, MOTOR STARTERS, MOTOR UNIT CASING SHALL BE CONSTRUCTED OF ZINC COATED, HEAVY GAUGE, GALVANIZED AND AT ALL SOLID TO FLEXIBLE DUCT CONNECTIONS TO REGISTERS AND 1. OCCUPIED HEAT/COOL: VOLUME DAMPER T: 631-979-0104 14.AIR FILTERS FOR HEATING AND AIR CONDITIONING SYSTEMS SHALL CEILING DIFFUSERS. INCLUSIVE OF ALL TRAVERSE AND LONGITUDINAL CONTROLLERS, CONTROLS, THERMOSTATS, CONTROL PANELS, LEAD-LAG STEEL. EXTERIOR SURFACES SHALL BE CLEANED, PHOSPHATIZED,AND FINISHED WITH A VD CONFORM TO THE REQUIREMENTS OF SECTION MC 605, CONTROLLERS, PRESSURE SENSORS, RELAYS, MOISTURE SENSORS, WEATHER-RESISTANT BAKED ENAMEL FINISH. UNIT'S SURFACE SHALL BE TESTED 672 THE RTU SHALL OPERATE THE SUPPLY FAN CONTINUOUSLY AND MODULATE(OR CYCLE) F: 631-979-3445 SEAMS.ALL DUCT SEALING SHALL COMPLY WITH ASHRAE 2013. OUTSIDE AIR SENSORSETCHOURS IN A SALT SPRAY TEST IN COMPLIANCE WITH ASTM B117.CABINET CONSTRUCTION COMPRESSORS, MODULATE(OR HEAT,AND/OR ENABLE AIRSIDE ECONOMIZING TO SPLITTER DAMPER info@manciniarchitecture.com E I. ALL DUCT SHALL BE CAPPED DURING CONSTRUCTION. PRIORIOR , ...TO SHALL ALLOW FOR ALL MAINTENANCE ON ONE SIDE OF THE UNIT. SERVICE PANELS SHALL MAINTAIN ZONE TEMPERATURE AT SETPOINT.THE OA DAMPER SHALL OPEN TO BRING IN 15. SMOKE DETECTION SYSTEMS SHALL CONFORM TO THE REQUIREMENTS OF REMOVAL OF CAPS ALL DUCT SHALL BE TESTED AT SYSTEM OPERATING HAVE LIFTING HANDLES AND E REMOVED AND REINSTALLED BY REMOVING TWO THE REQUIRED AMOUNT OF VENTILATION. SECTION MC 606. PRESSURE AND SHALL EXHIBIT A LEAKAGE RATE NO GREATER THAN 5% 2. MORNING WARM-UP/PRE-COOL: CFM/SQ. FT OF DUCT AREA. 8. CONDENSATE PUMPS FASTENERS WHILE PROVIDING A WATER AND AIR TIGHT SEAL.ALL EXPOSED VERTICAL 17.AS PER SECTION MC 309, INTERIOR SPACES INTENDED FOR HUMAN PANELS AND TOP COVERS IN THE INDOOR AIR SECTION SHALL BE INSULATED WITH A THE RTU SHALL OPERATE THE SUPPLY FAN AND MODULATE(OR CYCLE)COMPRESSORS NESTED FITTING OCCUPANCY SHALL BE PROVIDED WITH ACTIVE OR PASSIVE SPACE-HEATING A. CONDENSATE PUMPS SHALL BE SIMILAR TO BECKETT OR HARTELL AND CLEANABLE FOILFACED, FIRE-RETARDANT PERMANENT, ODORLESS GLASS FIBER OR MODULATE(OR STAGE)HEAT TO RAISE/LOWER ZONE TEMPERATURE TO ITS OCCUPIED SYSTEMS CAPABLE OF MAINTAINING A MINIMUM INDOOR TEMPERATURE OF SHALL BE PACKAGED AUTOMATIC CONDENSATE PUMPS COMPLETE WITH MATERIAL.THE BASE OF THE UNIT SHALL BE INSULATED WITH 1/8", FOIL-FACED, SETPOINT.THE OA DAMPER SHALL REMAIN CLOSED,UNLESS ECONOMIZING. ___= ACOUSTICALLY LINED DUCT 3. FLEXIBLE PRE-INSULATED DUCT PUMP, RESERVOIR, CHECK VALVE, FLOAT SWITCHES, AND HI WATER LEVEL CLOSED-CELL INSULATION.ALL INSULATION EDGES SHALL BE EITHER CAPTURED OR A. CHANGEOVER BYPASS SYSTEM 68F(20C)AT A POINT 3 FEET ABOVE FLOOR ON THE DESIGN HEATING DAY. FLEXIBLE PRE-INSULATED DUCT MAY BE USED FOR THE FINAL BRANCH CONNECTION TO 1. OCCUPIED HEAT/COOL: SWITCH. CONDENSATE PUMP BASIN SHALL RECEIVE CONDENSATE FROM SEALED. THE UNIT'S BASE PAN SHALL HAVE NO PENETRATIONS WITHIN THE PERIMETER OF CEILING DIFFUSERS. FLEXIBLE DUCT SHALL BE INSTALLED WITHOUT KINKS AND WITH NO EACH VAV TERMINAL SHALL USE PRESSURE-INDEPENDENT CONTROL,WITH AIRFLOW -® AUTOMATIC VOLUME DAMPER 18.ALL WORK SHALL COMPLY WITH APPLICABLE SECTIONS OF THE NEW YORK MORE AND IN ACORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. FLEXIBLE SUPPLEMENTAL AC UNIT AND DRAIN PAN.A LIQITEC SENSOR LOCATED IN THE CURB OTHER THAN THE RAISED 1 1/8' HIGH DOWNFLOW SUPPLY/RETURN OPENINGS AVD STATE BUILDING CODE AND ALL AMENDMENTS, RULES AND REGULATIONS TO THE DRAIN PAN SHALL DE-ENERGIZE THE AC UNIT AND THE PUMP.THE HI TO PROVIDE AN ADDED WATER INTEGRITY PRECAUTION, IF THE CONDENSATE DRAIN MEASUREMENT,TO VARY PRIMARY AIRFLOW TO MAINTAIN ZONE TEMPERATURE AT ITS .1.1 TEA PRE-INSULATED DUCT SHALL BE"HART AND COOLEY" F194 COMMERCIAL SERIES WITH WATER LEVEL SHALL DE-ENERGIZE THE PUMP.AND CAUSE FOR BACKS UP.THE BASE OF THE UNIT SHALL HAVE PROVISIONS FOR FORKLIFT AND CRANE OCCUPIED SETPOINT.THE RTU SHALL MODULATE THE BYPASS DAMPER TO MAINTAIN DUCT _ DATE OF THE LOCAL AUTHORITIES HAVING JURISDICTION. BLACK POLYETHYLENE JACKET, UL-LISTED, HIGH PRESSURE CORE, 16"W.C. POSITIVE, STATIC PRESSURE AT SETPOINT AND MODULATE OR CYCLE -- 1"W.C. NEGATIVE(1/2"W.C. NEG FOR 14"-20"DIAMETER), MULTI-PLY DE-ENERGIZING THE PUMP SHALL ENERGIZE A WALL MOUNTED RED LED LIFTING, WITH FORKLIFT CAPABILITIES ON THREE SIDES OF THE UNIT. ( )COMPRESSORS, MODULATE FDAD FIRE DAMPER WITIH ACCESS DOOR 19.A SPECIAL INSPECTION WILL BE CONDUCTED UNDER THE DIRECTION OF ALIGHT WITHIN THE OCCUPIED SPACE IN THE GENERAL PROXIMITY OF THE C. UNIT TOP (OR HEAT,AND/OR ENABLE AIRSIDE ECONOMIZING BASED ON CURRENT ZONE METALIZED/POLYESTER CORE, R-4.2 INSULATION. SUPPLEMENTAL AC UNIT AND PUMP AND SOUND AN AUDIBLE ALARM. THE TOP COVER SHALL BE ONE PIECE CONSTRUCTION OR,WHERE SEAMS EXIST, IT SHALL COOLING/HEATING DEMANDS.THE OA DAMPER SHALL OPEN TO BRING IN THE REQUIRED CERTIFIED SPECIAL INSPECTOR SUPERVISING THE INSTALLATION OF THE GREENGUARD LISTED FOR MICROBIAL RESISTANCE AMOUNT OF VENTILATION. Tanqel Engineerin-g Associates P.C. MECHANICAL SYSTEMS.THE SPECIAL INSPECTION WILL SHOW COMPLIANCE BE DOU;3LE-HEMMED AND GASKET-SEALED. THE RIBBED TOP ADDS EXTRA STRENGTH AND ' AVAILABLE DIAMETERS: 4, 5,6,7, 8, 9, 10, 12, 14, 16, 18,20 INCHES. 2. MORNING WARM-UP/PRE-COOL: Consulting Engineers WITH BUILDING CODE REQUIREMENTS AS PER SECTIONS BC 1704.15 AND BC ENHANCES WATER REMOVAL FROM UNIT TOP. ® CEILING DIFFUSER 1001, BC 1101 AND BC 1201 OF THE MECHANICAL CODE. THE SPECIAL 9. AIR BALANCE D. TWO-INCH PLEATED FILTERS EACH VAV TERMINAL UNIT SHALL VARY PRIMARY AIRFLOW TO RAISE/LOWER ZONE 4.AIR OUTLETS TEMPERATURE TO ITS OCCUPIED SETPOINT.THE RTU SHALL MODULATE THE BYPASS INSPECTOR SHALL BE ACCEPTABLE TO THE REGISTERED DESIGN A. CEILING DIFFUSERS:ANEMOSTAT MODEL PG PARAGON PLAQUE CEILING DIFFUSERS. 2"PLEATED MEDIA FILTERS SHALL BE AVAILABLE ON ALL MODELS. A. ALL AIR DISTRIBUTION DEVICES SHALL BE TESTED FOR CAPACITY AND E. COMPRESSORS DAMPER TO MAINTAIN DUCT STATIC PRESSURE AT SETPOINT AND MODULATE(OR CYCLE) COMPRESSORS OR MODULATE(OR STAGE)HEAT BASED ON CURRENT ZONE RETURN AIR GRILLE Middle Country Road,Suite 208 . PROFESSIONAL OF RECORD. THE DIFFUSER SIZES SHALL BE NOMINAL 24"X 24"OR 12"X 12",AS SCHEDULED,WITH Smithtown, ' MINIMUM 18'OR 9'SQUARE APPEARANCE PANELS.THE DIFFUSERS SHALL BE ADJUSTING TO PROVIDE AIR QUANTITIES IN ACCORDANCE WITH ALL UNITS SHALL HAVE DIRECT-DRIVE, HERMETIC, SCROLL TYPE COMPRESSORS WITH Smithtown,NY 11787 20. SPECIAL INSPECTORS SHALL KEEP RECORDS OF INSPECTIONS FORA DRAWINGS BY AN INDEPENDENT AABC CERTIFIED AIR BALANCING CENTRIFUGAL TYPE OIL PUMPS. MOTOR SHALL BE SUCTION GAS-COOLED AND SHALL HAVE COOLING/HEATING DEMANDS.THE OA DAMPER SHALL REMAIN CLOSED, UNLESS Phone:631 150.2800 CONSTRUCTED OF STEEL,AND SHALL BE DESIGNED TO INTEGRATE WITH THE A VOLTAGE UTILIZATION RANGE OF PLUS OR MINUS 10 PERCENT OF UNIT NAMEPLATE ECONOMIZING. Fax:631.750.2744 PERIOD OF 6 YEARS FROM THE DATE OF PROJECT SIGN OFF. SUCH RECORDS SPECIFIED CEILING SYSTEM TYPE. THE DIFFUSER SHALL CONSIST OF A BACK PAN COMPANY. 3. COOLING/HEATING CHANGEOVER LOGIC: SHALL BE SUPPLIED TO THE COMMISSIONER UPON REQUEST.THE AND A REMOVABLE, HEAVY GAUGE APPEARANCE PANEL ATTACHED TO THE BACK B. THE AIR BALANCING REPORT SHALL BE SUBMITTED TO THIS ENGINEER VOLTAGE. INTERNAL OVERLOADS SHALL BE PROVIDED WITH THE SCROLL COMPRESSORS. 2 tangelengineering.com COMMISSIONER MAY REQUIRE THAT THE SPECIAL INSPECTION REPORTS BE PAN VIA 4 POSITIVE LOCKING POSTS. THE APPEARANCE PANEL SHALL HAVE FOR APPROVAL. DUAL COMPRESSORS ARE OUTSTANDING FOR HUMIDITY CONTROL, LIGHT LOAD COOLING THE SYSTEM CONTROLLER SHALL DETERMINE THE OVERALL SYSTEM COOLING/HEATING CEILING MOUNTED EXHAUST FAN ( ) MODE BASED ON"VOTING"FROM EACH ZONE.WHEN THE MAJORITY OF ZONES REQUIRE EF ,, FILED WITH THE DEPARTMENT AND/OR THAT SUCH REPORTS BE OTHERWISE AERODYNAMIC, RIGID, HEMMED EDGES AROUND THE PERIMETER AND SHALL BE A C. COPIES OF THE APRROVED BALANCING REPORT SHALL BE SUBMITTED TO CONCITIONS AND SYSTEM BACKUP APPLICATIONS. DUAL COMPRESSORS ARE AVAILABLE MADE ACCESSIBLE FOR REVIEW. REPORTS SHALL INDICATE THAT WORK THE END USER AND THE BUILDING OWNER FOR RECORD. ON 7%2-10 TON MODELS AND ALLOW FOR EFFICIENT COOLING UTILIZING 3-STAGES OF COOLING,THE RTU SHALL OPERATE IN COOLING MODE AND ANY ZONE THAT REQUIRES SINGLE PIECE CONSTRUCTION. THE PANEL SHALL BE FLAT, SMOOTH,AND SHALL BE HEATING SHALL REDUCE PRIMARY AIRFLOW TO MINIMUMWHEN THE MAJORITY OF This drawing has been prepared for the . INSPECTED WAS DONE IN CONFORMANCE WITH APPROVED CONSTRUCTION FREE OF ANY WELDING OR FORMING BLEMISHES.THE HORIZONTAL AIR DISCHARGE D. ALL TESTS SHALL BE PERFORMED AS OFTEN AS IS REQUIRED TO REACH COMPRESSOR OPERATION FOR ALL HIGH EFFICIENCY MODELS. project and is an instrument of indicated DOCUMENTS. AN ACCEPTED RATING OF PLUS OR MINUS FIVE PERCENT. F. INDOOR FAN ZONES REQUIRE HEATING,THE RTU SHALL OPERATE IN HEATING MODE AND ANY ZONE PATTERN SHALL BE 360°TYPE. BLANK-OFF BAFFLES SHALL BE PROVIDED TO OBTAIN THE FOLLOWING UNITS SHALL BE EQUIPPED WITH A DIRECT DRIVE PLENUM FAN DESIGN THAT REQUIRES COOLING SHALL REDUCE PRIMARY AIRFLOW TO MINIMUM. service copyrighted by Mancini Architecture 1,2,OR 3 WAY BLOW PATTERNS AS SCHEDULED. THE SIZE AND ELEVATION OF THE E. DATA SHALL BE IN ACCORDANCE WITH AABC STANDARDS. , or 21.AS PER SECTION BC 1704.15, SPECIAL INSPECTION FOR MECHANICAL F. IT SHALL BE THE MECHANICAL CONTRACTOR'S RESPONSIBILITY TO TAG (T/YSC120F,T/YHC074F,T/YHC092F,T/YHC102F, 120F). PLENUM FAN DESIGN SHALL INCLUDE A PLLC. This drawing may not be copied ut APPEARANCE PANEL SHALL BE AS SCHEDULED FOR ANEMOSTAT'S TYPE A OR C BACKWARD-CURVED FAN WHEEL ALONG WITH AN EXTERNAL ROTOR DIRECT DRIVE O THERMOSTAT used, in whole or in part, by any party without SYSTEMS. MECHANICAL SYSTEMS REGULATED BY SECTIONS 107 AND 507 AND MODELS.PROVIDE VOLUME CONTROL, MODEL VD BUTTERFLY TYPE DAMPERS AS ALL VOLUME DAMPERS,AUTOMATIC VOLUME DAMPERS, SPLITTER CHAPTERS 10, 11 AND 12 OF THE NEW YORK STATE MECHANICAL CODE SHALLSCHEDULED. DAMPERS SHALL BE ADJUSTABLE FROM THE FACE.DIFFUSER FINISH DAMPERS AND A/C UNITS TO ASSURE ACCESSIBILITY FOR VARIABLE SPEED INDOOR MOTOR.ALL PLENUM FAN DESIGNS WILL HAVE A the expressed written consent of Mancini an or Infringements i f I PLLC t hit Arcecure . nrn BE INSPECTED FOR CONFORMANCE WITH THE APPROVED CONSTRUCTION SHALL BE ARCTIC WHITE.PROVIDE PUBLISHED PERFORMANCE DATA DETERMINED IN SERVICE AND BALANCING. ACCESS DOOR LOCATIONS MUST BE VARIABLE SPEED ADJUSTMENT POTENTIOMETER LOCATED IN THE CONTROL BOX. 9 Y use DOCUMENTS. ACCORDANCE WITH THE LATEST ANSI/ASHRAE STANDARDS FOR THROW, PRESSURE, COORDINATED WITH THE CEILING CONTRACTOR AND THE DESIGNER. 3 TO 5 TON UNITS(HIGH EFFICIENCY 3-PHASE WITH OPTIONAL MOTOR)ARE BELT DRIVEN, of this drawing for any other purposes will be AND SOUND. G. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL FC CENTRIFUGAL FANS WITH ADJUSTABLE MOTOR SHEAVES. 3 TO 5 TON UNITS(STANDARD EO ELECTRIC CEILING HEATER prosecuted to the full extend of criminal law 22.A STATEMENT WILL BE FILED BY THE OWNER(OR TENANT)IN POSSESSION B. FURNISH AND INSTALL ANEMOSTAT MODEL RME VARIABLE AIR VOLUME, COOLING CONTRACTOR THE SIZE AND LOCATIONS OF ALL RETURN AIR AND AND HIGH EFFICIENCY 3-PHASE)HAVE MULTISPEED, DIRECT DRIVE MOTORS.ALL 6 TO 8% THAT THE MECHANICAL SYSTEM(S)WILL BE KEPT IN CONTINUOUS OPERATION ONLY BYPASS/RELIEF TYPE AIR TERMINALS WHERE SHOWN ON THE PLANS.THE TRANSFER AIR OPENINGS AND DUCT PENETRATIONS THROUGH ALL TON UNITS(STANDARD EFFICIENCY)SHALL HAVE BELT DRIVE MOTORS WITH AN ECH DURING NORMAL OCCUPANCY OF THE PREMISES. TERMINALS SHALL CONSIST OF A SINGLE PRIMARY AIR DAMPER THAT SHALL CEILINGS AND WALLS. ADJUSTABLE IDLER-ARM ASSEMBLY FOR QUICK-ADJUSTMENT TO FAN BELTS AND MOTOR PROPORTION THE TOTAL PRIMARY AIR THROUGH THE TERMINAL TO EITHER THE H. THE AABC AIR BALANCING REPORT SHALL INDICATE: SHEAVES.ALL MOTORS SHALL BETHERMALLY PROTECTED. DIRECT DRIVE MOTORS. ALL F-1 BYPASS BOX KEY PLAN 23. SMOKE DETECTORS, COMBINATION FIRE/SMOKE DAMPERS AND SMOKE CEILING PLENUM OR THE SPACE AS DICTATED BY THE SPACE THERMOSTAT DEMAND. a) AIR OUTLET AND INLET DESIGNATION, FACE SIZE, NECK SIZE, INDOOR FAN MOTORS MEET THE U.S. ENERGY POLICY ACT OF 1992(EPACT). QF NJ&t,v DAMPERS SHALL COMPLY WITH SECTION BC 909. THE FLOW INTO THE RELIEF TERMINAL SHALL REMAIN ESSENTIALLY CONSTANT MANUFACTURER, MODEL NUMBER, REQUIRED CFM, REQUIRED NECK G. OUTDOOR FANS BPB ) VELOCITY,ACTUAL CFM,ACTUAL NECK VELOCITY. THE OUTDOOR FAN SHALL BE DIRECT-DRIVE, STATICALLY AND DYNAMICALLY BALANCED, �� Y�Y j``v,Q REGARDLESS OF THE PRIMARY DAMPER POSITION.THE MANUFACTURERE SHALL b THE AIR BALANCING REPORT SHALL INDICATE EACH FOR AIR DRAW-THROUGH IN THE VERTICAL DISCHARGE POSITION.THE FAN MOTOR SHALL BE RT�J ROOFTOP AC UNIT 440 '� ` / �� PROVIDE A MECHANICAL STOP THAT SHALL BE FIELD ADJUSTABLE BY THE } PERMANENTLY LUBRICATED AND SHALL HAVE BUILT-IN THERMAL OVERLOAD PROTECTION. a" ' n 1h HANDLER AND AC UNIT, MANUFACTURER, MODEL NUMBER,CFM * � �. ,,. 11 CONTRACTOR. THE TERMINAL CASING SHALL BE FABRICATED OF MINIMUM 22 ,_ ?,i." t' REQUIRED, STATIC PRESSURE, REQUIRED AND ACTUAL OUTSIDE AIR r 7, CK GAUGE ZINC COATED STEEL,AND SHALL BE LINED WITH MINIMUM 1/2"DUAL DENSITY CFM. H. EVAPORATOR AND CONDENSER COILS Cj y 4:' I FIBERGLASS INSULATION CONFORMING TO ASTM C1071.A RADIATED NOISE INTERNALLY FINNED, 5/16"COPPER TUBES MECHANICALLY BONDED TO A CONFIGURED m ik ' . c) THE AIR BALANCING REPORT SHALL INDICATE FOR EACH FAN,THE 2 � _ I� SHROUD SHALL LIMIT THE RADIATED SOUND LEVELS NOT TO EXCEED THOSE SHOWN ALUMINUM PLATE FIN SHALL BE STANDARD. EVAPORATOR COILS ARE STANDARD FOR ALL 3 W, MANUFACTURER, MODEL NUMBER, CFM REQUIRED, STATIC PRESSURE, t� '=`° IN THE AIR TERMINAL UNIT SCHEDULE.A BYPASS ADJUSTMENT DAMPER SHALL BE TO 10 TON STANDARD EFFICIENCY MODELS. MICROCHANNEL CONDENSER COILS ARE Q 6F86I �; LOCATED ON THE TOP OF THE UNIT TO ALLOW FOR FIELD BALANCING OF THE UNIT REQUIRED OUTSIDE AIR AND ACTUAL OUTSIDE AIR CFM. STANDARD FOR ALL 3 TO 10 TON STANDARD EFFICIENCY MODELS AND 4, 5,6,7.5, 8.5 TON TO MAINTAIN A CONSTANT TOTAL FLOW TO THE UNIT FROM MAXIM UM TO ZERO d)ALL BALANCING REPORTS SHALL INDICATE FOR EACH AIR HANDLER, HIGH EFFICIENCY MODELS.THE MICROCHANNEL TYPE CONDENSER COIL IS NOT OFFERED ��O�F_ySlOc'1�� BYPASS.A BALANCING DAMPER(PROVIDED BY THE INSTALLING CONTRACTOR)SHALL AC UNIT AND FAN, THE FAN RPM REQUIRED, FAN RPM,ACTUAL, MOTOR ON THE 4 AND 5 TON DEHUMIDIFICATION MODEL. DUE TO FLAT STREAMLINED TUBES WITH BE LOCATED A MINIMUM O F THREE DIAMETERS UPSTREAM OF THE RELIEF AIR AMPACITY-ACTUAL AND REQUIRED, FAN WHEEL SIZE, MOTOR HP, SMALL PORTS,AND METALLURGICAL TUBE-TO-FIN BOND, MICROCHANNEL COIL HAS TERMINAL TO ADJUST THE CONSTANT VOLUME FLOW TO THE UNIT.THE SEQUENCE MOTOR BHP,VOLTS/PHASE, HZ. FULL LOAD AMPS, SHEEVE BETTER HEAT TRANSFER PERFORMANCE. MICROCHANNEL CONDENSER COIL CAN OF OPERATION IS BASED ON ANEMOSTAT CONTROL PACKAGE BR-A-5202. SIZE, SHEEVE SETTING, ETC. REDUCE SYSTEM REFRIGERANT CHARGE BY UP TO 50% BECAUSE OF SMALLER INTERNAL \V- ELECTRIC CONTROL SYSTEMS:ELECTRIC CONTROLS SHALL BE COMPATIBLE WITH THE 10. SPECIAL INSPECTIONS VOLUME,WHICH LEADS TO BETTER COMPRESSOR RELIABILITY.COMPACT ALL-ALUMINUM LINE VOLTAGE FEED TO THE TERMINAL AND SHALL INCLUDE A STEP DOWN MICROCHANNEL COILS ALSO HELP TO REDUCE THE UNIT THESE ALL ALUMINUM COILS ARE TRANSFORMER AS REQUIRED FOR CONTROL VOLTAGE COMPATIBILITY. THE A. THE CONTRACTOR SHALL RETAIN A SPECIAL INSPECTION AGENCY TO RECYCLABLE. GALVANIC CORROSION IS ALSO MINIMIZED DUE TO ALL ALUMINUM ELECTRIC ACTUATOR SHALL BE DESIGNED FOR PERMANENT STALL WITHOUT PROVIDE THE SPECIAL INSPECTIONS IF REQUIRED BY THE AUTHORITY CONSTRUCTION. STRONG ALUMINUM BRAZED STRUCTURE PROVIDES BETTER FIN DAMAGE.A STEEL CONTROL ENCLOSURE SHALL HOUSE ALL CONTROL HAVING JURISDICTION. PROTECTION. IN ADDITION, FLAT STREAMLINED TUBES ALSO MAKE MICROCHANNEL COILS PROJECT COMPONENTS.THE WALL THERMOSTAT SHALL BE SUPPLIED BY THE(TERMINAL MORE DUST RESISTANT AND EASIER TO CLEAN. COILS SHALL BE LEAK TESTED AT THE MANUFACTURER)(CONTROL CONTRACTOR)AND SHALL BE COMPATIBLE WITH a) MECHANICAL SYSTEMS-BC 1704.15 FACTORY TO ENSURE THE PRESSURE INTEGRITY.THE EVAPORATOR COIL AND STONY BROOK THE AIR TERMINAL ELECTRIC CONTROLS.THE SEQUENCE OF OPERATION IS b) HEATING SYSTEMS-BC 1704.23 CONDENSER COIL SHALL BE LEAK TESTED TO 600 PSIG.THE ASSEMBLED UNIT SHALL BE BASED ON ANEMOSTAT CONTROL PACKAGE BR-A-5202. LEAK TESTED TO 465 PSIG.THE CONDENSER COIL SHALL HAVE A PATENT PENDING 1+1+1 MEDICAL C. RETURN AIR GRILLES SHALL BE SIMILAR TO"ANEMOSTAT"MODEL AC 11. START-UP AND MAINTENANCE HYBRID COIL DESIGNED WITH SLIGHT GAPS FOR EASE OF CLEANING.A PLASTIC, LAY-IN TYPE CEILING RETURN/EXHAUST GRILLES&REGISTERS SHALL BE DUAL-SLOPED, REMOVABLE AND REVERSIBLE CONDENSATE DRAIN PAN WITH 10095 MAIN ROAD ANEMOSTAT MODEL AC35(1/2"BLADE SPACING) FIXED BLADE, A. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR START-UP OF THROUGH-THE-BASE CONDENSATE DRAIN IS STANDARD. MATTITUCK, NY 11952 NON-ADJUSTABLE GRILLES, MANUFACTURED FROM STEEL AS SCHEDULED. PROVIDE I. CONTROLS ALL EQUIPMENT. SIZES AND MOUNTING TYPES AS SCHEDULED TO INTERFACE WITH THE UNIT SHALL BE COMPLETELY FACTORY-WIRED WITH NECESSARY CONTROLS AND SUSPENSION GRID SYSTEM AS SHOWN. GRILLES SHALL HAVE A NARROW BORDER B. THE MECHANICAL CONTRACTOR SHALL ENGAGE THE SERVICES OF THE CONTACTOR PRESSURE LUGS OR TERMINAL BLOCK FOR POWER WIRING. UNIT SHALL DESIGN TO ENHANCE APPEARANCE AND MAXIMIZECORE AREA. FULL-BORDERED S MANUFACTURER'S APPROVED(AUTHORIZED, CERTIFIED, ETC..)SERVICE PROVIDE AN EXTERNAL LOCATION FOR MOUNTING A FUSED DISCONNECT DEVICE. DRAWING TITLE URFACE MOUNTED GRILLES SIZED FOR LAY-IN APPLICATIONS ARE NOT APPROVED. PERSONNEL TO VERIFY PROPER INSTALLATION, SUPERVISE THE STARTUP A CHOICE OF MICROPROCESSOR OR ELECTROMECHANICAL CONTROLS SHALL BE BLADES SHALL BE ON 1/2"SPACING,AND SHALL RUN PARALLEL TO THE LONG OF ALL EQUIPMENT AND CONFIRM THAT ALL FACTORY WARRANTIES ARE AVAILABLE. MICROPROCESSOR CONTROLS PROVIDE FOR ALL 24V CONTROL FUNCTIONS. DIMENSION. BLADES SHALL BE POSITIONED AT 45° DEFLECTION ANGLES,AND HELD B. MECHANICAL CONTRACTOR SHALL GUUARANARAN IN EFFECT AND PROVIDE WARRANTY TATION.TEE WORKMANSHIP AND THE RESIDENT CONTROL ALGORITHMS SHALL MAKE ALL HEATING, COOLING,AND/OR MECHANICAL RIGIDLY FIXED IN PLACE BY REAR MULLIONS WELDED TO THE GRILLE FRAME. VENTILATING DECISIONS IN RESPONSE TO ELECTRONIC SIGNALS FROM SENSORS CORNERS SHALL BE WELDED OR STAKED FOR NEAT, UNIFORM MITERED CORNERS. MATERIALS FOR A PERIOD OF ONE YEAR FROM THE ACCEPTANCE OF MEASURING INDOOR AND OUTDOOR TEMPERATURES. THE CONTROL ALGORITHM SPECIFICATIONS PROVIDE BLACK, STEEL LIGHT SHIELDS FOR CEILING PLENUM RETURN USE AS THE INSTALLATION BY THE OWNER. MAINTAINS ACCURATE TEMPERATURE CONTROL, MINIMIZES DRIFT FROM SET POINT,AND SHOWN.PROVIDE A BAKED-ON,ARCTIC WHITE FINISH. C. MECHANICAL CONTRACTOR SHALL FURNISH THREE SETS OF OPERATION PROVIDES BETTER BUILDING COMFORT.A CENTRALIZED MICROPROCESSOR SHALL AND MAINTENANCE MANUALS TO THE OWNER OR OWNER'S PROVIDE ANTISHORT CYCLE TIMING AND TIME DELAY BETWEEN COMPRESSORS TO REPRESENTATIVE AT THE COMPLETION OF THE PROJECT.THE O&M PROVIDE A HIGHER LEVEL OF MACHINE PROTECTION.24-VOLT ELECTROMECHANICAL APPLICABLE CODES: MANUALS SHALL INCLUDE ALL EQUIPMENT, O&M MANUALS FOR SAID CONTROL CIRCUIT SHALL INCLUDE CONTROL TRANSFORMER AND CONTACTOR SCALE AS SHOWN PLANS THAT ARE IN CONFORMANCE OF THESE APPLICABLE CODES: EQUIPMENT,AUTOMATIC TEMPERATURE CONTROLS AND SEQUENCE. DRAWN BY ARC • 2017 NEW YORK STATE UNIFORM CODE; USE GROUP B. DRAWN FOR TET • 2017 NEW YORK STATE CODE:SUPPLEMENT(PUBLISHED JULY,2017 EFFECTIVE OCTOBER 31,2017). CHECKED BY TET • 2017 NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE. • 2017 NYS BSC SUPPLEMENT TO THE NEW YORK STATE ENERGY PROJECT# 20-021 CONSERVATION CONSTRUCTION CODE(PUBLICATION DATE:JULY 2017, DATE EFFECTIVE OCTOBER 31,201'7). • 2016 NYSBC(2015 IBC 3RD PRINTING). SHEET NO. • 2016 NYSEC(2015 IECC 2ND PRINTING). • 2016 NYSPC(2015 IPC 3RD PRINTING). • 2016 NYSMC(2015 IMC 3RD PRINTING). • 2016 NYSFC(2015 IFC 3RD PRINTING). M-501 • 2016 NYSPMC(2015 IPMC 4TH PRINTING). • ASHRAE 90.1 2013(JULY 2014 PRINTING). • TITLE 19 NYCRR PARTS 1220'THROUGH 1228,1240, 1264,AND 1265 AND PART 300(ACCESSIBILITY STORAGE). SHEET 4 OF 4 - NO. REVISIONS DATE - i ! I1 ISSUED FOR REVIEW 5/12/2020 : . �/_Z/..//.//1: I I : : I ! : . ; i AND COORDINATION 1 I i 1 ..........................�................................�.... ................................�......... ......................................................................... .. .._.''..'..'_ .. . ... . .. ..... ... .. .... ..................................................... , ; ; ; ; $ : ­...'....__..­­....... ................­. ..........­­­­......i '.'._.._­. ..........�."�f­­.­.......�47­­­'­:­­ . __ ,_ ­-"," �.......... 2 95% ISSUE ";:�**.::: ..... y; % p� 5/14/2020 ; i . '� .._:.:.:.'.'__ ......; : � : �'; _:�_= �"' . ;�.. .........=*.......!_� . . ' .. ��...�....[­­.­1111.1.1...I.......1.1"..1.1...I....I.........I......­­...I�1.111, .. ......� ; ! . ; : li, : ....�..........................�........._---11 : : i ; i . ; i . ) I�""_-._': 1-1 � : i ': � LEC. NOTES: . : ; �'.; _. I .�­) I .....".1; i : : I—— I .."', r ! i /�. : . . I I I '�' : i : � : I I ; ,"I -, : / . i , 2� i I \�......... ......I..., � ! 3 . i f : T / , 11fi � / T I � COMPLETED 5/22/2020 1 . " :1; ; .­­/ : P-2 i! !; ; i I : : Lk' ._�J I " : f� ; .1 � i; , � : ...q.:.::::.:4:::i i : 1 r I ; :; : $ i . I; ; i � i .; ... i i 1 r ; � , !! , � i i ",__/; 1 1 . I. LOC,ATION OF EXISTINC? ROOFTOP, OAS-FIRED AC, UNIT 19 AS SHOM. CONSTRUCTION SET I \ I , : : i !� � .4:: ._'/ : ! i i r I : 1 : ! ......11 I : -TX : TX_5 : . i LANDLORD 15 RESPONSIBLE TO FURNISH AND IN-STALL NEN GAS FIRED 4 COMPLETED 6/0412020 ; :r : : ! � ; I I I i , I : I : i I i .1,I I I ! i . : . ,� I I i : ....I...- I i i : I i: ,I - i: : i __......... � .. :: : i �' ROOFTOP AC UNIT. REFER TO MECHANICAL EQUIPMENT SCHEDULES AND . .: : : : ". ....� ; r : . : i ;: : : i : I : LP- SPECIFICATIONS. : ;. . ;T : i �.................. _. .... .....1.1.111". .,...,.,..,. ..,.....I i 1: i 1� I i � / CONSTRUCTION SET : i : : : ! i ­­­­­­ . i : 11 :: t 11 i 5 COMPLETED 6/12/2020 i : I / 2. ALL DEVICES SHALL BE CIRCUITED PANEL LP-2, (2#12+C7) UNLE55 I ; '! : i : � S r ! i I ! - I t . I i 1 : i jfi : i i i OTHERWISE NOTED. ---­­­­­­_.� I............�......................_... � 071 .....................;' ==�; __': L.�!;.....----..--.-.------i I i \ CONSTRUCTION SET : ; . .: � : . i : . I !..: ............- ..........................................._4 ...i...I j .. + : i : : . ! � I i i I :. i i I i....4 ...........k..........� . . i . ! ,i :i ­....I : 5. EXACT LOCATIONS AND MOUNTING HEIGHT OF ELECTRIcAL oUTLET5, : 1 : ' 6 ISSUED FOR PERMIT 7/07/2020 . . 1 t! i I ;! : i T : 1 : i ; 1/1 ; --S AND OTHER DEVICES SHALL BE AS PER ARCHITECTURAL i ; : � 11. .......I " SWITCHES : ; I : - , i : : � ­", i / PLANS. I i I ; i . I : : ! I . I i : 1 i � : : � . I 1 ! � I I : i ! : i :_­_'__­­.......I.............�.......� I . : i..............I... ...........11....I.— � . I T � r r : 1 r L..................�............................ .. 1 . 1. .+.+­'+­­+ i I : � ; i 'I— "'.".'.."'.. .. ; i i t ; i i ; � . ... ..............*.........................�.......; � ! ! i I i I ; ! � � ; i I I ! � I I . i i : : : : ; : ! : ----..................11..1.... .....".1-1......-....­­­.'­.......�: : ; i ! ; : ; : ! ; i : i ; * - : : ; I......­.....I : 7 ; 11 7U.) ; :: ': : . I : I.- � [it) ' i . : : :1 I � .1 ';"' . i __ ; -, : I . ; '! - I-------­­ . I I :+ : 1 1 i I i- I - . I H � . i ; I 1 1 1 I I i L�' i 11.1.11, : I ! I ................................. i I i i � -_ ­ �.....I— . .I.I..' -1.............-11....-- ....I.....; : � ; : . ' : I I ; . I ; '"" iI � ; ; L.. _ . ... . . ...".". .. . .. .1.�:i'.':::'i:: :.. ' _ + + ­ - : ; ; ............... : � i ­­­ . ; ; I ., . ... - ..1*.'.'.*..'%...... ­­'.............................�...............................�....1 - ' ; " - - I—- '..__ + � t; F .....�..........;_ . :.....-.......=.- :............1111.. .....� '. i __ _ 1.111,11, ­­ ­ ­....­­­ ­ � 1 .� ­­ � � .1.11,11,111,... ..................... ,; I_'­_���. .... .... .... .... ,._..____'_­_­'­'"I'll"-,��l-l�.1-�--,-.-.�,�".=.'.+++.***.'.'.*.+**-'+.*+.+..+.*.*.'.*..*.*..-"-,..+*"-.."..I........1.......�.................!___- i ; i � ii : � I� : ,1111......_............................................... . : i i i I i �_+ -.... _ -_ _ _ - - - - ....1.................... ...... ­­.. ....... I......I...........................I........ I . ......................I.......il..................................­.................................................................. ................i....I ''..._.......................... i . i � 1 i : I ! .................I...---.-,"..-",-,. .... ... ...,. . .I....I...­__­­­__...' _- \ � � ! i i i . 1. I � I i I a 0 \ � " OCINI 2 EXISTING ENTRANCE POWER PLAN MAIN 1 14.1p=1 9-Opp ARCHITECTURE ! M U I CONSTRUCTION : ! ; i r i I : i t i ! ! 222 Middle Country Rd. Suite 314 ; I i ; I : ; i ! ! : ! Smithtown, NY 11787 r � I i T: 631-979-0104 i i I F: 631-979-3445 i ! i ! � i info@manciniarchitecture.com ; i ; : ; ! I i ! r.................... .........................­ . .­­I., ..... .........................................�..............1-1........................................-.1.............................................. .. . ..........�... ...............-....................................................................... I : ......*********** ! ! : ................__.__....­......................!...............­­­­....�............................_1.1__11_.......................................................................�..................�.............................................................................................................�...............�----�..................�.........................�......................................... ; I ; ­­... ..­­+ I.. ........1- .. ..........*...*,**,***,*. ...................�...................: r .............................................I.............­.. ..........�......­­. ....... ... .....­­...............................................................................................................�......................... i I i I . . ..........................._.____-_--_---__-_-----.-_-__ ........ .............. -I............------------------------------------------------------- .. ....................................__............�........................... .........�...... ; S F +' '­ .1.1.11........I...I............­­_ .1...........11.1----.--..",.-,.,..�-.,.,..",I `:: ........................- I i ! S � ­ - __--,-,--*-------.-----.-.--- -­-.­---- -- ­_­ -------. ___ .............. : i ; i ! i i : 71 i E...... ":��"­- I ; ; -"A- ____6____ z -­--- ------ --.-..------..--------7,.---­------ � ! ! ! �� i i T, ! ; / 14 . : : : f : : 14 -�/ 14 41 : . � / i ! ! : 1/1 ' 14 14 �Al a i X 72" AFF a I ­ : . I ; I ! : �// �� i - ; /I i : �� : I : : : � . I ; : f i ; � " TV : ; : ; i I ; /� .� : ; ; j ; i i ! ; 25 ; : 5 ; X . i : ; : � i r �' : ---.._..._7.._.. i : .A ; - .1..,.:1111.7711 : i $ i I :: : i ' _'; ..../ - � � ­ - - - - - -­ .-­--� - - ' � ­ - ------ - --­- - - ­--�. ........1 ! ! /11 i : ­­ ........ ­�...... ; I ; ; I .I Iz=7 ' 7_Z=...........................................­.......­......­­..."'. ...... ........I.........I.......... ..... ... ...................�.......�...............................I...i ; i i /I 14 : "...I....l * . '51 4 : i ; A i Ii i s ; . / : r / 14 ; : T : 1 � W i i � / I + i : 1 14 TZ ! : : ; : : i � ,=Cl 14 i// ; 1:1 : : ; : i / GR ! i : ; r i ; i il� i : ; EXAM : I/ EXAM. ; I/ i OFFICE/M ; I - i : � i f . ­ ­ . i :1 ! ! � KI i : �� 1 1 . : i : ; : ; ry t ; ; ! . : ; : I : : �.................. ...................................­­.......III—. I +' : i i ; EXAM : EXAM // ! � � 55 �/ ! i . ; i : V, 107 1 : � : /�7" ; � 109 I . : i : ;1 1 ................*....*......... .. ............ ; :: ; +: i i �/ ; i : i i i �­­­_ .1111. ��" �'.......... . i ; . f...�­ . : i i 105_... I : ' 103 1 i ; . � � ­­ �............... ............................ � : . . I : ; : : I i ; : ; : : : / i : I/I � 106 ; : i . .....J . ............. : ; * .................. K ..................11 6S _ 6 : f-1-1- / ; �* 11.1.1....... ZZ///"�­`/_/a'/ DD�] /� WAITING ; STORAGE ---CLEAN ROOM . . ...........I � "+ � ! *160 I : i i : i -, �...................�.........I . i 71 r / . !;; r ------ : : . :[ �;; : �/l - 21 .21 . / � : I i : ; - : : .; .. ; i _­- . .--1-- i : I ! : .I ['++* : , i.........112 ; ; : ; . ! . TangelEn � z ......___; : ; ; .' : / i i 1 113 ; " " : ....11---� i -clineerinq Associates, P.C. .......... �I i : ;. : : 11 I / ;-- --- -+, 42"AFF 42"AFF ; : ;; '1-1 i / ,� , , , / " _ i Fr i 1. : : : : ' I—, i I // 1 Consulting Engineers + : ; ' : ; : I 11 11 I i ............... I ////�/�/' ' ' i ;__ .. ....... ..............-.1-.....�............................................ . . .."..............4+2.."..AF.F.....� �/' I ; �//. : : H - i ; : ; : : z ;; : 1, i : ; r \ // I . : i : : � ' . i �/ \ .......- --____-----..­-__--------: :i . : _-1......__.._.....­_____' /1' \ : ; 1\ i ; ; / . . 1",1 2 ✓ . ; ; : I 1� : i I i ; 1�...........I...­- - 4" '_ "'----------- i i / �__J_._17 : :: - "I .i ! I 4 f��" : 5�11 . : :: i I : : i� .. � . '1 .:.....;� " ' , .......�__/' : �� �_ // 55 . -...�...........IV / _. '/i \ i . i r i........I...... '1 // 4 -, I / I i % : - i/ I ... ............ ' -'�-- FCI 4 11 � : 1 -11 - ;; � 'ZZY : GFC[�-GFC1 1".? �: . - ' ! TO EF-2 11 7 I � i \ \ 11 �// ......___.:..._ ...:_ ... - i I � .......... . - I ; . i . T. . : / iE::..�]i......� � i i i ' : '"i . w�I ! ✓(�/ + i L - i ' � -Z�'�� �".�/_' . I I ; - * ; ! I ✓r GFCI /I � : .. .1, ?'/. : 11 : � ') - i i: : z / , 2 : i . : : : ,✓ �... 4 1 � � 1� " AIQ AFF :.+,,a�,911 ; ' I '*'AFM'F I ,P�,e T , -I _ � '::;�' _....;'�! i 1 1 i r ' 'I% , . � �11' i V / //i CONSULT - - . -71 \ II I �/ 1// _�// , \ i f . �,ii r , ! ; . � i I i '��"'_' f i I Ji . .1.... /// i I �/. I 11'n�*�- I_. ' ; ; I �4 / / A. ,� ; � : ; 48* a 1, I ; I I 1 /' _ � / �.z ­ : I �✓i i r 7TO f : / 285 Middle Country Road,Suite 208 . ! � R !;,GFQI� � ­ ­ .111 1 : i . ; / ....J. ' r.l.". I i . ; Z.7�Z?._��/".z z// I.-F.; ; ­ - _ , - :1-]"'7_1 . 11 I I....__I..... ____ .I— ­ i I ' ' ;" 7 / ........ 'a�Z'737z­-*1 Smithtown,NY 11787 i I �.'Wr :7' 7 i��� ! ; I Z.; .1.J ....'................­.11...�.... ..­ I I :'/��"._: ��'/.`/­�`­�­�­`­ 7'31-1 / 'Z-_�* � " � � '/ I ' - .- .. - _1 / i ­ I I I/I I 1. i i ✓; , ­.- /'//"�;'/ L .Z Lt .. ... .. I , ... ....�. .//­ I. ..I- ", lt/"� i ! / EF-2/ [-�//� "r 1. ...'! '. '" '� / __"'..- r-P �'�""';� Z._...: ; ,�_"r '/ /o-,-/, , '/�e : ,�r/ ii [ i I i .. � 7"-/" / ; ..' . I I Y/ .. .- - ..... ... . .....�: _ i��_" I I '0� $111-1 T : Phone:631.750.2800 ; / I : . t............................................! / : I � : ; / / ­­1. , : ! / ""'I""', � lep ; 60A5/NF/3P i '� . ­­- � . .... / , ; ­­`­"'/ Fax:631.750.2744 4: I : ! : i � , " : NEMA 5R --- / LT, I , ; . . .. ..... / / 'TION ; li . I­­..............- : ; / MA,STA....."..' ; / tangelengineering.com 115 � TO RTU-1 ...�..... ; � :i i I10 1 ! ; : ..'. . / : ; ----- i: I , : : I / t: 11 I � i I 3� I I :1 I I I ! ; . .: I RTU-5 ON ROOF / -Z I li ! :: ; i :i ; ; (SEE NOTE 1) ....'__..1.'_-_" .:: � ! : This drawing has been prepared for the : ; . ...................................; I :+ :.....­..............,..............1 :. ­+­.�......T I...........................................; " I : : I I I =::...�-_-'-.--.-- .: ;_I 1: la � - -, i .­_ : 16 i lep 0 - indicated project and is an instrument of 1: ; ... ; r"'.111....... : - �':­ . : 7 ..........711�Z....... 0 :: : : 0 ................................._.........................___.......�..............I -1 ; . " I t V/1//2�///://Z" ,�'71'�+/*+'*' 7 zz":71.,** ZZ"'Z./I ; ; . i I.......1................ �......I....-, .: ; : ,,, . service copyrighted by Mancini Architecture : ; ["'i �' 1. : : .r. __ ...r F ; : ; , � '� + . I .........--.--- . ; T; I ..................�. .. ��.�� ........ 1. !"� : I r..... 11 r---­................... . PLLC. This drawing may not be copied or : I .../Z //­/`­`�'.] '� j ��'_ , d '"" ;; '.�t...........�....I ..............****---",- � 1 ! :. : �� H_L' 7' ;/ - .r /11 / ...�� I r I , / " , ;.//Z+/",-+/"��"-���"`'71.1-,X* //,./.,_" _­.",�A� : /1' L____......... ­­­ =Z///��������//,Z/�������".,."`/��`�"`/`-`-#�#����`�/*��"+�*"`.�/"`���-"`�"`�`�.e,��/��-"'Z" ' /Z.�p ===z" 9 �-� ' ' /­/Ia­�' ­.- I �! ,� I i ; ; r . --- ✓- ",""I'll. . IV/-* . I �:/- / I . .�'./I__­­I ..+*+-7Z1 ,17 - u'll'X'1_1 ,��2 - 7/ i , ! 5 I ��'l ! �/ .. � :i 7 z"7-7'i' !��/,/ . Z Y_ : ;� i � : . i i !: , i ; � i : 40 42 : i ; �!.+ !_j� ; DEDICATED/ ; .........:1 i i � _.'.'_',�... ! ! : '�� : �� abb� 1 -� ZZ:� [ : ! ./- ....Z'' �-/ - , - � � � ! ; ; i 1. .1. I '�)! ! ; : : i P ; i i W/1 i i* i "'L1_:�' / M. used, in whole or in part, by any party without : / . qp=//, 1 < ; I j � '6� 1 � : � i 2 .. : 1 . : / :1 ; : : I : : : . I : % I � i . NA i H 55 ; ; : . �1 /!GFCI ......J ­.'­.- ; �.....[1W_+'..�'�:'Ii..................�Iwaf%14 N ..'E" -4'_ i I i , i : � : I ... : : � : : ; ; : ! : i : ! 1 i i ; : � ! i *1 1 / 11 : V! the expressed written consent of Mancini . . : i : �' ;� t i i . i ; ; ,t I ; ! : ; : ! : . I I I : : : . : : .­­­.. I . I � : / '+­.........�" : . i ! I ��'l : PHYSICIANS � : ��48*AFF ': ! : ': � � ff P� ;;��/� 12� 1 22 �...�..............i. ! .....),11 I ,= I 48"AFF' � 1/11 1 21 14 : ; I I .1 I i V! : � ; 48*AFF ;' i L.................�................�...___.'_.,___.-..-.-..---_��_........-, i i . : - TX-I ; ,/� .................................... ! ; ; // : ; : Iq T ....- ///lull., : � V 14 �� i " . r : I i I.........-—.....................I——.......................... ........ 11 i Architecture PLLC. Infringements or any use ;i ' ' r . ------____...................I 25 +1 ,. ..' ..I ./ -zw ! I : /'r � ..........I'll. i r, �' ; ,� ! 1: : / // T i ! : 01 ! , ; i .. : I ! P..' : ­' i �/" 11 1 i i \ ! i I ; 7. il : 1,i ;: I I i i / t ! i ; : z .. I � ; � : ; , OFFICE ; I MA STATION ; ! ! :: - / " I" ; : of this drawing for any other purposes will be ; ; :1 i I : . i : ' . ; i : I i i I ' ; : 1 i : i . . i . ; ; ; I : - ; : � i - . I : I . i i : :1 . I i I ! i :� I" ---i � ; 1, . : . : : i --"I i ; . - ! I I ! : V, i : / 11 . ; . ; I 16 ; ... i ; ....... ; prosecuted to the full extend of criminal law : ; ; i ....- I : : . i : ,). : : 1 117 1 �' , 21 � 1 p (__.I. . f 1 : �� �51 1 MED ROOM I. �� 11� RECEPTION ; / 1; ; . : . I'll.......�..............._ ; i I ­ . . ! ! ! ! : .; I f . ; � /i; ; �/)' .___ ''..., ; ; ; I /' : : : ; '. ...:­ : ; ! : I i �� ; �.......'+ / 5/i �// . : ! ! ! s ;' ' : ; i : i: :'�: �/' : i 102 ; i i : ! I : ; ' : : :i . : i : �. i 1 : : i i I : �r ; ; �� EXAM r . . ..........1 ; ;____.'_.'......- i ; � . ; / "/"'= � � 1 122 : �// :; i 55 : i : �� 1 1 1 I :..........I ", t� HROOM EXAM MA STATION � : I ! : : �� ! i ;' I ......­­­­ ; I I : : '' . ; i 51 ✓: i i //: i . �//' f ____ " V/ 111. ��111.i "+*+ ! : . :i � � ; "I i A : ; : : I. : : 9 : ; : ; . ; i i t i ; 104 i � . . ! . i '� ; :. i i Ill i : ; I ; : : : t. I : i � I : : , :/ ; : : 0:�"11 18, : 108 ! 10D 1 i . ............... /� � : : i I i : ; . : I I . : � : i �� DEDICATED / � ; � 0 r/ I ­.....I- . : .; . F i ! .�.......... . I i . 1 1 ! I I i ; 1-............. i . s I....-1 t I i A* ­­­­........ �1 V ....I :: I i / i i ! : I ; . - �'; . I i i : : I ; : ­ : ;' : : / . . I i KEY PLAN + : : 1 \ i' : 11 [/ 55 EXAM OBGYN +I"li '** - , : : : : : : : : : : . . 1 ,­­: .'/ i : i ! I . . : : . I i ; �/ /.IV; : ; / : 1 � . I I �� : . : : i �� / -' . ­ : ..... . .'.....­­ ­ . . 1�''... . ..", .........I..._............_­­­­...... . ­ � ........­­ I'._�-:::..��'t ,� ... .........................1-1...­... �.........._­�..­.....�............­­:­.;�;;........... .............I............. .­ � " t . 1- � _.........I- . " 1.r4" �// -1.1.1.1........................�........... ...�........................�........................................................................I...I.............. . . ! ........... T I ;! ]! / - � . : : K � . :+ 126 1 V I �� i : . : --t......�....�............... I V � -� � I '� 6 ...........................I........... �:.......................................�....�........................... .+--1...............i�......�...........................// ii -- I I I ! ...........................I........... . ---..-,.-..__.............4.......1..............�......__........................__._ - ..........................._........_...... _ --F --O� I—. . ; '/ .......... i' .-'+.... ' i , F I I t/'� +­�' ­ i - � i + ­ ­ i � 1 : : . �.........­­.. //i I—......'.-;..7.=..............._ ...........................- I i ill: '� i i V � V 11 � I + Z+11", .... - __............. - I..............�........................................................._ ­­........................... . 1-1 � '/­.... . , ; 11// , . � ; : 4.....7" - / /I i _ . ; + I If t 511111�� Z* I / 'Al 1- .' ...........___....________ 0- Ff",1'/ : ;. � I i i '/ I(,- I � r _Ii� '/ " * ' ��' Zt� - : 2 _�................... �....... ..-...................... .. i _._....­ � . .....................................--..--- k '1+1 : ✓ . ­ 1 , V/ : : "Z,/,.�///.//,/ � +.Z11.1.z­..__z.Z­­/... 11 I . ; i .Vi ; / / /1 �/ : : lei i _1 55 :i �� i i 0 i . i --,, E. 0", , f � W ;1 .; i I ) re --')� 1 1: . i : -�\ ;r ; %%I ✓!�' i I � I : (91701 EF-I ! i // I : .; : ; !01,/I f! � ! / : 1 1 ':,,' : i : 1: // ! // : t I� . : ; i I i" . ... i : , , ;i / �" i : � 2 : 0 W : " 1. : .. : I 1, " ! . I ; i '�'" ; t �� 1, " : ;A. 1 ' i ; z il . " , 1; I a 0='11 i : _.," � : + I LP-1,1%5 �'� V., ,r//. V , ,, ,4 - : _/ + ,,, � 11 � . i: 1: i i : _ ; . : i ��"_' ;0 11 '_ �J ;i , i / �// 1��/" , "I... I , 0 : _-- I 'I" .......1. T. i : " I :i : ;1 / . :.A. . : : ; ; r ; i : i : I . !: JP1 I , ' . � ; / : . i I r . .,i� i 1� P-1 , / r I , / . : I I - L ; / � : 1. :i ; ! // I ; iI . : . I ; 4; ?" V_ 11 : ; : , ; i / y i i 'I , I :: / . I !I /-', / ! i: A : �� � : A I / : / �� � ?, "I I l✓- : . ! + Li I V ! i �N!7111( I,!,`�'�: ! /I i 21 �.....................I——............. ...............................................................................................................................4 i 1 i , I � +�/'I(;, 1 L i+ i�4 11 ' ; /+. i ! I j : : 11 t I 11 V/ 1: � + : I I r/ -� 0 � 1 ; : : i i i . . i . f I H114RP I � I I 1 �/ //1 i ✓I 1 25 1 I :: �:,,-✓ J �P," 1 : ; : I 11 ; ' i �� : I I i; : ; i ! i : Vi : vi I I '/ �/ ; I--- - I : ! :i K i r I /I 11 ! i 21 Idl ; 1 11 I(- "-_t" - - -,- i I T "y w� ! I . � I; .Vi V ; - '_L_�7'� '-"-'�/ : 1 ��y : t; : I I �Xl . : : - :. - I 1 H 11 U, ­­ , ­ il r ../.... ......................I...­'­­ : ; . - : :. - // I ! -1 - ". Z i f � P/� / ; ; ; i - . 1 L�. ; i; , i 1P 'i I ; // /. � ..- - L...........................�......._//. : i "; : i , .. I 11 ./ VZZ Z///ZZ­­///1"Z' //'�....U Z/' Zzi� I /",)/ -,"' ** 'r - : '=/ : i - : i,/ I � 1; I—. I ' //"X "'.'//._'..'.//// //"// I........ i -//_//z'// � : - , , �Z+//"'_/ ; ......Z//..�...... ....,,__�_"' .1.......//:/:�_ . .. , + /////-*...zA_'___­­_*-----------­*. ........*+ �2 ' .� ' - �� ­­ . , _9... _q? i.;6�zzz==Z'211 Z' Z" 11Z1=."211. ,- ..' ... ........42? z....//P 1.1 / �.�' 6 3 8 61 <7 i /// ' Zz�z�`/*­`+`�"`­ , ZZ7­ / f , / ...... �*.�­.'. z /�.' '.. .' ­ZFT19 zZ111.zz=z � , 1 =_:­/*"/��`�"`/­­­­­`''Z�­.�"/Z`/�­�/**­*...* z7///.+1..... z �,/"./`&��-`�""��/��"`/""�.,��`/"��`/�`���`//"���`�`*�. �.Zz F---� 1 7, 7" i i ; .....----.__-_-----._.........._<_/ .' / I i 6' �...4 /�_ I i I i I ; - N, i : i , 1::::: :__11::1:::1:.:: :::::-_::::::' :- ...-. ................ ; : ---..I i i ; i / I 0,- ssko", i ; : SS0"" ; ..........................�...�......�........ � 16 TO 5f:13-I ; RTU-2 ON ROOF i I - q .........I...................'.�' . .. : I : I � � i 6OAS/NF/5P i ! I-- "' t ....­­­­­...... -1 ; I � ..--, ..;, � : ; i ; : 'e; ELEC. (SEE NOTE 1) i ___1 "­'­�' ; i : 1: : I .. : _*�\ NEMA 5R / .: i Zh, 6OA5/NF/5P / 1 ;: / � TO RTU-2 � i I i :.. i Th "LP-2 NEMA 5R. I/ � r i TO ' � � r -5 r ; � \ r ; r ; ; ! : BREAK ROOM ..." ; r , . ; : :' 11 . r I � : : ; : : ii ,++*+I 15 la le� : .......�_"'� : I ; � t : " I i ........' : : :'! : � i �'.'�'.'.,"�+�'�*.'�*+*"."'.'-".L.11111.11-1...........T: : : ­.. ­ : ! : .... - T r i : ; .' i : --- I : ...............1 , : P_ . . ' i Z*7-­.. I -1 . ...'i 9 I 1 .1 r . t I I I i j 7 !/ ; .. . - ­...... . ."­..... ...-. .- ; . ..... . T ; r I.-. �.14 I r ..'.... z/�/' z -1 : � 7'+* -�..'7. : 77" rr * � - � ; . ...... Z"/.' 1! I 4 ...... 11 �... : . 7' i i ; . ­4..... Z'/ A.] : I i !i I i I ; : �: ;� : � , . '+/--.".,/,/'_1� W�' I. --- - Z�IZ'"�.11'.Z'*.Z*�*117,-�.-�" " I I z,,,z/z�.'z////7,�/­I j_ / ZZ //' /1"; 7.; i /�,� - ; : .", _ � / -1 �. i :V 'i t :� .../. I....., 2 7' . ; : . / , " 'e= / 4_�'Zz_.��;70= . -, ZA: Z�11117..... ; + ; LP RTU ON ROOF 77111=�i'I/ 7�:// /'//'` _�.i - i ' �."��'.' ',_Z//V/ "// :: �'�Z/./­­Z�+1.113 '9 Z7" ./ 171 ­ / ­ " I . i . : ; I . r � il... .. I'll.__.___'/_­�............._'... .. : (SEE NOTE 1) I I : i � 1 /I � : 0 2 ........'.... ; i . ; : i . . � r � : : i: � i . ; : i i : PROJECT - ; i i I r.,7-z,'T,'-- . : +'-, ; i : : : i 0 : � z i �i : : - : � : I � ; I : 2 : i: ; i r i : I. 1; cl�.....i : 11 F-Cl .......11---� I ; I , j. ; : : ! d . i \ ii i; ; I 12 OWAI ;i / TX-2 /I r� : i .'._"''-1_+__.'....... � . / ­ . ; I r ; ; . i: s i: 11 12 \ i . i ....iv.�------- ..................G i ;: i : ;. v: 1 1 � 11 : : ; [____.:'2.;..... :! 1 i ; . ; ; , ; T : � : ; ; c : : ; i , ' I / \ ;! : . : ; 11 X 1� 4� r.....r"-"", �/ i I I i .+ A , :: 2 2 , ,: i : \_ ". Z_ "i� ­ Z.'* /`i �/­......../'lif�/' /� Z* 7....ZZ7.+ __ i 7/�XZ& * .................................... . � z �� . : .� i I./ _z..".*../ .'../.'­` .. � - � - �12 11, �� 1111 �1 - . '� ii .� i r 4,4� 0: ' ! � �-fill. I i � � 50 1�✓//1 ��A 12 "GF .. . I : " i ! : :i ; /1' ! \ ! / *AFF 48 AFF L===� I /. ;; � . \ :: ""PHLEBOTOMY ; ,/. i� / ; / i�" I : � ' : - - s! ✓ ' . 1 11 ; V ; .1 .T.-I­. . : i a✓ 1� 11 /I ; 1/48"AFF v ::�:...j: i - I !L...............i ��" : : ��...........___..' / : : . :i / . 1: ; 1i / I......''...�.............................. I . 1i / zt t ;. : . ; I : 11 \ ii : i; 48"A / . : . : I :: ; : I : ! i! 11 i ........... . , '' ; ..............................I...I.......I.................... ...................... : i I I NEL LP-2 : :i t . / 1: / :i i .1 STONY BROOK r H : i . i i i ; ..................................... I ; / i............�............ ___._ ................­...�....­­­� : : : !, / i i ; /I ­­­­ � ...-. : : i " 1 : . ;I '/ I i i / : / . � _....'...1 I \-NEPq ELECTRIC. PA i : \ \ ii ' j! CARE LAB r/.! � / / ' '' ; \ i ' : _ \\ ; ; ;; - I Ti : . " i " I i : // .... : r--+ ✓� ­ I : i ; , : t: i : : I/ / i I - 14 : i : � , ii 11" 5 , : I/ !i � 4 ___j.........i ii : � : I . .......... ,/11 i 1 ....... ; . ! , . I.... ; ...... I r� "" !I .1, � I L�---" r -_ : : '__ i I k/ '____ IN ­_.- _ 11 ; : _...... L // ____' / +­* ! : I I : _..... r . .: . .. ; : L ! ..:. ; I ! �� r I : 121 : ; . ...­........ --,.-. i �� i� I : �.. ; : ; ; . . I ' - : : - : I i MEDICAL .1 ; ; ; . i I 1/1 I 1! � /111 : . / :! _­ -11 :/; I 1 ; I . '... . i i ; r i f I�/..' / I I d . i : I : I : �' TX_2 i L! i A . . ;'....... I 1 T : il I i :/ / .......�"' :1 : 4H(/ PICKUP ; 1 11 I I : � � - 10 9�/' WAITING 10095 MAIN ROAD i : . I'll . : I ! * I H : ; I ; I / V EXAM EXAM : / ; i : j i : -� :." � " I . i , : : r ' ' � .' ; ..'....11..........................�.......... : EXAM EXAM ,ji-," 12 . - 120, 1 . . .. .) /rr : �/'. 1 : i I i I r 1.1-1.......­.....� . : ---..�;.......I L�i� i � 7 . i ; i T; , .­+­ : /I ........ .. i i i !: ..s. �.. � : ! 11: 1. . : : 1 r I.- : : ! 1, /11 '�/ 127 ' A t. ........�.... MATTITUCK, NY 11952 � 120 ; ;' ! 130 : i . ; :; I... ...................... .........­­­......; /1 : ✓ r . I i ; /; . i .�� /,j i i i �� r 0 : ....I i 129 1 I......J_.... J : : ,/.' ! i i : V, 56 � � : i ;........119.1 � � + ; :, I� '/� EXAM 'A I... ' ./ ; � �/'+ : I ; I + : : �'- . � M X /I . I oz- i : I - i : : ; .1.11 ­­ , ; d iI ,­'� .........I.......I....---1 : i / /A � j ; : + I i i ; : i i I -"-, i i ..j 1� ... _- ..- ' 125 1 A �/l_:�:::�::- ' 12 . /. BATHROO EXAM OBGYN ; 10 DRAWING TITLE i . i !r.; IY r.:� . + r ; ..... ...........i : / I : �'; " :; 1 , i , � f i ; I ///,:,I.--.__.--- ' 4 ,. . /I I- ' " i i ir//'* :1­ r , i [ 123 1 i . /. . i . ; . : �.. : : � i i . : ; I r: : i �� � I : I I I-):1. -. . ­ : i p P 1 ­.........I........................I............... ; :; I i'�" V... i I i 0 I 11 r , ; : -Iri .. , : t: ; ­ : ' : + : ; . ; : I i; i . I I ; - ; ; i : ; : ; i i . . i : �P-C)0:� �" : : : il !O�. /! : lrj� i i i ;: ii; - : : ;� :. . I� '.. ": ; A : , i ; : : �� i; _:�... I r . /I : - : : I : .+ . i ; I 1 . r" O��g _ "' - ; . ) ? : : I . � d I : . ­.___­...I——.1...I....I...­­­.­i r i . / ! � : . : ✓­'. +� : ........._1 ; / : ; �� " � I ELECTRICAL POWER : I : . z > �// 2 it 1 : i : U_ r I I i! . ! �/" ; i . i : i : . I // s : . .u<- -) .!,-./ I 10 1 . : \ ; / . , . I � , I 1 /. I 0 oi;'l �// 2-.c , TV f . i ; r i i i lg� I � ­ : � I PLAN 11 I LJ_ co i ! ;� 1 � 1�/" Olt ; � : ...i�' ; i ; �:06 ; . ! :14 . , ; I 10 . i � i � : -... ; i'/1 10 . 672" AFF . i I ; .012 12 5 = -: w-71 .f 10 . a i : : i : : ; - - - ; ; _ i j . A. ; i i I "....'........­_..........I... : �) ­�..."I'll'.-.,.......��­­1.­.....1.111.111,...I........­­­......................................_"._____­-, ­� . . .. /' '.__.._.'r� I� 1 , . ., Z='= - - ''--"'.�'*:�:"i ! i --- ---­­--­.­.--- -_....-:-.-_...............=........77� -.."-."--. -�........ _'�'.­'_.' i ��. I............­­..........................__.­ ,2��41_5'1 ! ; / ; i i , _on ! (D -�I- LL I r54, .­......-1 . : ,+� ; j . I _." .�/.............�54 ! ----1.11...... 9 ---I� I ­ 11 0 : �/! i li�__ 111111_-., ,��'�:;.;.;:;�;..;;;;;;::;:::--+,-��:: :- -, � .ji­ �­­­.. .._... _. I . ....11.1 I-------­_­­...........................­_­.­.­__._____��___._ -..-. - - A- __..'_.___..___.__'___._.____ . . � --�.-...+.+.+.-.+-,++.-.+�l+,-.,-,. : I ______._.._._ i ; ; __ :_d�11 ............_.............�........................��V' .........�...... ___ �r 11 �: .- __ _-V/ -/Z ,--.--. %79 " , ., ..". . ...�> I_........._......._....._ _.""""', ''".__ , ; :' '*......... ........� 1.1- ­­­ .. ' . ..................11.....I............................I., ....'.......... ­.­­­­­­ ...............9......__________......................... 9_IO._____.___V_q?___ I �:­ . � ­­­­ '_ 1 i.� +' ­­ ­­..... .:_:_....�!.. 1 -7 'T .. .................*.....* ........� � � .. ....I—....­­ -111111-� � I...1-1....11., �............................­­­­.........;.1 1 ,7/ �=7 - i 1 I ......1.1.11-4......�...........-, .1 - �._ ......=..�.­'.:+;.:­:::::'.:..... . .'=........ ..........�...-j-_..... . 1. --.1. ­:. '..'... i �. ., r .....-_ - -_ -9--Li I .1 ...­......­­.,...­......................L-.....I...............=.=.=.. .. ------.-- I : � ; 1-i i�--- ___._._.___� : ; : � I t ____......_ i; t i .�.­............11.........I—....I...........�...I 1 I I : 1: ; � : i i .: ...................................�.....�........I.....................�.....___'.. .....­­ ....................... .....--1.....................I..................................­­ .... ............�.......�..............I........ : i : I .. .............................t.............. .......... +­­­ ..".. � ­­­ 11.1-1...I.....I............................................................�............................................................�.....�................ ................... ­........................................................................................._...�....................................................�....' _'­­­­........................................I——..............................................._...................................................�..................-1........_......."------.. ..................................................�.........�.............................................�.............._....................___1111_.......�.............. .: i . .................................I...­­­­..­ . --...''.11,.......­......­­... ........'.....-1 I.......­...­............... ..'....... ....._11­.....I.......I....... . ...1-11.1"...._..... ..................... . -1111-1-...�..................�..........I..................................................... i: . ...........-.......................................J......I.... .......... .... ...I............................. . ........­­­­ +­...........�....__.................. .....­­....--1...11.11-.... ......................I.......................................... I."......".­­... ..........I......,.....­� ­ �� � I—. I——...I_.......... ......................... ; .......-111 : i i; ­.....,.......I.....�..............I......... ...... ......-I.I.................................................................. . .......... ­­­+­+­.............................­­...........................­............................................................................................................. : .1 ...........................-11,.................._...... ........._.._..._..__._l------............................................................................................................. ..............................................................................................................................................._.._______..__.__.........�..............�............�.........................­­__............._­..............................................................................-_ i; I i; I ; : r ; : : ci / SCALE AS SHOWN ; .r : ..............................�­_­.­'.....................I..........­...........I—......­...­­_­ --....1.1..................­..........I...................... -'.....1.1.....I I . �­ 1. ..­ ­1.­­I....I.....................................�............................................----.1......­ : // i i f ; .; .......................................... .I.......-...­­..................................­­­I I­­.....__.. . .. � �­_1-11.1'..'.I'll, ­.­...�...­­.­.....­­..................I...­.....�........I......................--.-'_....i.............. ................I—- ! .: i I : .. i ............................. ............................... .............................__..______.__._..................................---_1_114.'.....____....................................... . I. : -_...�...................................__._.._­­..­.....__­_ / : ii ....._­____._._'._____._.............I..............................._.._.._.._________.._....­­..... DRAWN BY . i : ARC � i ! 1-1......... I : i ; i ; i ! ; I i : ! DRAWN FOR TET . I i i : ; ! CHECKED BY TET : PROJECT ECT# 20-021 I : : : ; ! : : : ! : DATE I I : : --/--/---- ! : : ! : : : SHEET NO. : I . E-101 LE P5� , , . �Lp_ , � I , � (Di I I ! I : //1.1 !�0 I /. , / ��---. / I p��/ �). ,/// N. A §:�' 11 �// �111 / // I /I / � _/ // ////-/ ///Y/ EF 7 , Zzz/_/ I IX �� ( " '/ /' . �//;.' I- "� ' � ki I I I I� p-! /, .11), � A .�/ 6 r�d �''IF I. ' ' ' * * ' I i I I - /1' � 114 /A �' 1M I Jr �r I � � : � : / . . GROUND FLOOR ELECTRICAL POWER PLAN 1 1/4 10=1$-Olt - SHEET 1 OF 4 � I NO. REVISIONS DATE I 1 ISSUED FOR REVIEW 5/12/2020 ! : I / ////:! I � ; i i AND COORDINATION i ; : : ; I ; i I I : . : : i I...................................... .............--.1-1.1... .. . --- . .- - .... ----............................................................ .1....--..................�............................................................................................-....-�.......�......................... . �----........ TO ..t�........ 2 95% ISSUE 5/14/2020 � . ...........................�... .......................... -.1-1-1....�..........�.......-11-i ­­­­ --l' i - -1-1. i :1 ( ,---------*******'*........................ '"'- * *.......­**­-­-­-----­ i I : -� i I F-- -- , * i ; :1 ! ; � � i :1 i ; I :: ! : i -.1.1. .: i 3 COMPLETED 5/22/2020 : : ;: ; i i---i �-' :: i i i f i ;: :� i T I i . 1, : - 1; ;: 1, i �� :; 1: i i : �! !, :; i - . i . i .:1.1. CONS i� : �, i i �� i I I i i TRUCTION SET I I 1 � ,� i ; i I i . � it i i: I : an i i ! i I i i i i 4 COMPLETED ; i i 6/04/2020 § I I : i :: : .........."....., : i 1: .. i i ; i j! :�. ! I I i � i i � �1 I I : i ILP-1 .: --.1- �.... : � ; i : i I / i : CONSTRUCTION SET .1-i ; T - -� i ; ; i i ! i ; 1--.-...............................� ! ; i � � i ; / i i 1-1 .1...I-- -... � .. ; ; I L i ! ; , I i ; ; ; ; ! I i : ... : i i 11 i ; : i i ; : i 5 i r"--- - --,- -- - , - - � ; I ; I / ; I! i COMPLETED 6/12/2020 ;i i ; : � . : ; i ;; i :; i ; � :: 1 I ; : i : i . ; r. i i ; i . ;i : i i ; i :: 11 ; .1.....i i i : � :: I I ; : i ; ; ; : :. i . j i t : 1. ! ; i : :: ! . .........................�....:�...-1- CONSTRUCTION SET : i : ! :: I : : : ; . I -----.." L...............--....................---� .--.11. ! z r i ; i � 11 .1111, - I 1.1--j! it'.... �....I............................- i : 1 ; : I " I I'll � , ;............... i I ; � 1 ; . � i; . i. ; : ; .1 i i ! . : : i : : I I . I I I..........-... ................. I ... .....�- p ! ; 7 - 6 ISSUED FOR PERMIT 7/07/2020 . ; i i . ; ; ; ; r*-''-" z I ; ; d I [....� 1 � : I ; I ; I � i i ......i! i ; ; I I I � ; � I 11 : � � ; ; �i i... I 1 � i � : : � 11 r / ......... ...- i i : ; ;, ; i ; . i i I . � / I ..... ; ; i i I : : : :,: " : i t r 1 / /;� 5 ; 5; i i : ; � i i : : : " ; : i i I d ; I : ; , -.1............... ..........................-1-......... ....- ... .1 I --1--1 .. : : . : � : . ; I! ."-.--, /' : ; ; : : - ---, ; i : ; i ; � I i ; i i i I i i ; i � , I i . : i � 1 ; i � � i : i i 11 12 b i i i ; i i . i ; i : 11 I i ; i i ; I i i i . i i i i � i i i i i i i i . ....- �....... -1 I 1. ..... .. ...1-.... i I I ; ! i i--------..=-.:.-..--...- i I i : ...I................. .. --:,.:::!......i : i :T : I : i i I...... ...................i I ; i i : �". I.............. -........I....-......I I : i I i : i & T i i I � ; t : i � i ii t I.............. .............................- .. i s . ! i : I , ; ! i i : i i i ; i i ! i i i ; i i i 1 ; i ; ; i i i : ! : �...�...........�..................................�j-....................�..............................................OC4................,","; ...�....... i i i t-- - i i ; i : ; . : i ......---. - I i i I i : , ; ; i . I i r I i : i -- --- ** -* , - T ; I I I i i : ; ; . � ; ! I I...i ; . I t I I ! : : i : i i : i I i 1 I : : i ; I : : 1 i ; i � i : I i I ; I I ; � � 1 i i 1 1 ; : ! I i I � ; i . i i i i . i : I . .... ..�---------.-,.1......-.1..........- i i s i : s-1-1--l- I.... ..-4�.............- i : I i : t- **.......4 I i I �.. ........1.............. I : i ,.............I....................................---......................�...... ..........I.........--... I i i 1 1 � : 1 '. . : I ; i I .......................] I i 1 I i ; I : ....-... I.-....... . ----: I ... ....; ;.......:...:.......:.;..:.....r.:--w:�:1 --- --... ... -..bd--dF-- .. -. i i i.... .... - - - - I . --. ... -*,*-- , - - , .... ..--- - . I�� ,**-****"*'*'- . .1111 . . .."......- ..... 1 ,-1----.-1......[��-.:... - . . I I - � � - � -------I--� - -----T-�- i 11-i....-- -11.1.I- . -.-I...----l-....................------�..............�.......................................................---...--.......--------.t;i :-11.1-11.1-111 - � � I � .� I ;: � ;i 11 :i � � I I I :! I - � : : � , i , i i � i*******.....**........... i i i \ : i J , i i , i i : ­- i - i --. 1 i I I EXISTING ENTRANCE LIGHTING PLAN I"V'I' A N C I N 1 2 1/4 11=1 I-019 ARCHITECTURE M U I CONSTRUCTION i : : : i : : ; : : ; ! ; . r i : i : 222 Middle Country Rd. Suite 314 : ; : � . : : : : ; : ; T i : : ; Smithtown, NY 11787 : : ; : I ; : : . T: 631-979-0104 i : : : : I ; ; I I F: 631-979-3445 I I i I I : info@manciniarchiiecture.com ; ; i � i i I I i : i � i ; i : ; I ; ! i ; i ; F i ; r : -1-11-111-1-1 11 I --------......I-- --------------------------------- - ---------.-------------------.---..-..---.--------- i.-.,----------..-..--.-""...--- --------------�----------.----,-----.-,..,.-,...,.--.---- ---. : -i-. ......... .......- - - . � .. :. . ... ------..- -----------=--------==-===-=......... ......... ....I.... ......I.. ......... ........ ......... -.- .-.-- ...... ......... .......... .......... .......... .......... ......... .......... ,..-- ......... .......... ....... : ----T--] : ; r ; : ...... -.1'.... ........ .-- ....... ......... � .. ........ ... .....�.- = ........... ......... : i ; 7 I- -.1. ......... ......... ......... - - - -... ........ --..... ---- ----- -....- - - ..-..-. ------ ---- --..... ...... ... ........ -- - . ......... .......... ------- - -- -- -.-..- .--.-. ...-.- - : : ; : : .. ......... .......... ......... ...... ........ ....... -.......�..............................;.......................................T..-........................... .........................................-....-..--.,--------- ------.....-...I- ---------...--........r--------............. .......... --- ... --...---- .---....-----.-. ...............................1--------.........T...................................I....-----.-r ..............---.......................... I I i : i : ! i �i ........... F...-- -------------- 1.........................----.-.-----.---. I . � : I z : . .......�..........1. : : : : . : 1. ; i 7! . - : j : ; : : : i i -- -"-- ��"' : : i i i i � I , . . ; i I � � - - : 7 : r, .-1--.1-1-..................................- : ; : i i : == : � : : I : : I k� i : I : i -1 : . i ; : / ; � :i : t =.i ; I ; i : 0) I/ I : : : ; i 01!2h� : ; : I : : ; t I /i �11 i : . �'-' I . ! i Ill . : 1//1 p i f . i ; i i : i : ; i ; : i : '� : s r J!! i : : : i 4 ; �. i I I : i i : . r : : I i i . ; s : :. � � : I . : 1; i . I i i ;:! . . i : ; : i i . � ; i i i i ! : ,: i i / � i : i z s I ; � i I I : I I �i I I I � ; I � I I i i : : :, : ; : . : : ! i i ; ; I . I . �� : : .1. -...�......--.I .... . - .....,... / ---- .- 1-1-....I.................... ......................... .---.-.-------.... . I : . ; - � ....I-'...... � ...----.: -..- /:-.---- ----,..-......... ..........-.--...- I ; � :: . �, ..............-.-"..- ---* . ..-. I :1� I ((/!!!� : I ; : d !I, : i T I � :1; ; : : i 5 : 5 : I . i I i �//. ��i i i I i : � : . ! �� i i i : -- .------- - :1� : i i : : I : ,� i A . . . ; l� ; � / . : ; : !I� ; ; / i !!, ; I : : I I ; : i i : ; ..........I......................... I - - - � , - -- - - i � ; // z . //, : ; , -1 !Z11' ; 1-11 "'....- --.1--...................I........1----.....- ; 4 i : ! i r - - r i : i //, I � ; I ,- -/ - -., ZZ17 7/-'/"*"'--'- i I i a a I ; i I : � ..! ! .........�...-1-11-11 I......I.................. .......................... ............................. ........................�......... ............................ .............- .............. i ; i "'/ Z . . i... -------�-------.---...--. ..................... ........................ --.. ........................... -11-1---..........�.............. ----.................. - ...- T EJ A .......�....-............. ,------..... ......zz.- ................r.........................................................................--.- t -...�................... // i ; I : : . / . ** ` - i - - - - - - - 7 " ----- ........ -.. . : : ; ; r . . i � . : i 1 : . : : : : 1:1 ; I : ; . ! 1 i ! ; . : It . z ii ; : . : I � ! . ; /. : : : ir ; : i i ; i : ; i / � / ! ; ; . : i : I : : : : I 4 i ; : I ! � : I ;:i i ! I z � ; ; � i : I &W . : . : � . ; � : 1: : 4 : : i i .......- i i : i : : ! ; : ; . -- - : I : I :; i - � I i . i ; : : i ! �;: � ; i /t : � i I i : : 1 EXA i I"--- ,-- i I '%'AM ' / EXA /I OFF CE/MGR --- --- ----.- ---. : I M : �, : WAITING : i : : i : i . ; i ; : : I : : i f I : ; : . .-] ...................-,..".. .- ... � : i r --J ; : : . � i I 1 log !: -/ : i 1 / :1 ; i ; i : : I i -// I 10 i � -XAM ,�...' sl :; ; : i i �.............��.....I . , 1_ 101 i . ! i 11 : I � i ; � i-1.1--.- 1; . : : : I i :�� : i : I ; ; ; i : : : : ! I -........- "17=-���..............�...-1...�............111.1... ......i..............I....... i ................. -- , ..- i r 1 1 ; i ; : . ; i 5 : I ; .1. - -, - -�...-- �..�--ZZI - �/ i : 10, : I � � : . : : t i i s i ; : ; i 1 - 1013 : i :.. . ........ I ! ; I.................. : . i � I - : I r-Ah.15),-VIAA 1,...I -.] f... ; i i ; � ..... �. ""Ilillillilloillilillillij " -1. �� � -1. ........................- I.............................../-------1�11......... .............I . I : i 1:1 1 I......�.......................................... ..............................�.... .....................: ..................-1- ; i i ; ....... - : i s : i i i ; ! ; i ; : ----//----- ..................:--------- -4.. [�K i ::i . i i ; : ; �/ .... ... .. . ��- --­-"--- I I--..---.-..-.- i : ! i z I �-- �e'I, 1 ,- -11. i : : I . i i ; i � I z i ;: I ; ; : i 7 i : i i i I � 4 :� - i .I -. i : i ­ I : . i : I I I : . : I ; : i . i : i - : ; : . ; � ; -ORAGE............... i 1 : i . I i : A : � i I Tan-gel En-gineeringAssociates, P.C. : .I....-........: z . : I i ; . I I /, ; ; i : -.- ----------------------- �i .- : . : : ! ; i : : i . i . : 1\ . -- . , . I i i i ; : - :1 / - : ; ; i : I !: : i: .........111-- z i� . i : i i i � ; i : : :. � i i i / " -1- 113 � I i : . z 'i 0 s I - ----- i . i . I:� Consulting Engineers : :1 i :i - 11 ; ! i : r -- i ""'.­ : . �� z : ! :1 i -I-. ; ! : i z ; ; ! i . � : i : : . ; : ! . I : ; I - ; : I I ; . It X i ; i . ; ; . . I : : ; � : : ; : : . : i i I ; ; . : i I : ; ; : I : i i ,�I / I , I 1 I : I I - : : ; : : : / /1; \ . : // ; i i i I : - i ; 5 , : ; ; - - / : I �--- i i : ,/ /,�/ I _ � ; �.1 /I/ i I : i [i!i . : i : . : i : : i i i i i : .1 - : : i I . i s : i/.11 1 ; / 1! /� ! // / .1 : : ; : ; : i : : 'r . . ........ ..... I. i i / i i : I I � : �.......... �- � I. ...I.... ....1.i.....I i , : \ i i /., 1 : : : ; : i . 1. : : I : - I i -. : / // -� I I - : ; t ; i . / . . . ; I ; 1 1 i �- : : . �. 4.........+......... . ......-.... : ; i : I....1.1- :1.....1.11.1.1...-I.............�;........................11........ .---.1;-1---.-............... ......................�.........................,........I......-..................---......-...--....-i-.......--.1-1-1; /--! i I i ; , i Z. .." ........................ ..... .1; ---.........� 1.1-1. . 7� .1 r.... i : . ; . I.,........ � ---.-"-....\- --...........................................�...................................1.1-1�......I...�............ .I...............I_- ----------I............... � 11...I....................... I i ; : i i i I : I ; : i , I ; ; i . ; i: i : j I ; ! /1, i i : : ....-.. ; i I i .. � , � � � I 1�,ijl,,)Li i . . i , : : �/ \ : . I . K ; /1 11 . 5 : / , / . . : I, i i I i i : I 11 I I � i i i I� Z77.1 -. i ��.' ,i I i i / z Z1.. ,� T r--4 .�-= � i ; \ : : i i i � �i i ; .: . r I / : ;: I . I . : ; ! i : i � : i : : ;: ; 11 . i � . I . . � . / : - I �k ; i : I i I q : �11 i . /1 I'll I ! i � i I f / r : i \ I /i : � i . i I . I / ! I, -- -.-----.---.......- ---- . I ; / ; ; i V i /A 'i � . 285 Middle Country Road,Suite 208 � : I : ; ; . ; i I i i I . : ; i : i ; : : ;t i J z : / : i :t . ! ; A......!- . I i ; :; 1 i I 11 ! / ... ....-I.1.....-e� i i 1 /1 i i i . ; ; $1 : ;t : \ 1 1 . -...-... : / i � i i . : i : . ; -- - - i . : I I 1� : i � : i ! i � . i ; : i i : : : . � i : I . i ; i : . . ; ; z i ! i : ; ; : I : V,Ai , , ; : 1i 1 : ; � $ V, i I � i I ! i . ....; ; ; I 1 : ./I i - i I I � - 1 7'Z./z� /I ; .�......-.��--, ; : � i ; i . 1 ,4 � i � 1 � i I lfb . : / , i i k ; : - � $ -... ...... Z,;�,11 I� i $ .! . �ZA ; Smithtown,NY 11787 1 1 ! ...........�.............. .ill'""'.. ................................. I .1.1 i - / ���; . J ...-... : / , i : : 7�//,� 7 , �, � 1 5 � ;- /; / i I �� : // : . zl:� - ....-,-----,--..................�..................--.................-i........- ! I : : Ix --�� . - Zl../Z ��fZ"`�`-Z��`- //` "/�/���`-/��-��/�-`�����`/��`��/���`17z�.zzz��`/��d / , -- --/ .-.... / I a , : / - i / .Z. i ;/-* ; r��/;//,// i 1 .....i�r I / ,i-- -,,�....I.- .11,/ I . I :............. I : ; . T�z - - - .- C1 ''I i / � ; ;; 1-1 Li '7 A .." 7 , -... .......... -;.) . , I 1//J2=/`=.... - I'll : . ...... -......",......��......--.-I.........I-- I I �,/Z�� I : i Z....-....... : r i : : t i ; I . _- ; 4z Y' � : Phone:631.750.2800 ; T ; �--- � 4,I, : /' / ; i ,// , � ! ; I ; . ; ! : i ; � I .1 i i I i ---,.------.---i I : ����!4 : / // r I i ; ; ; : ; . ; i ; : ; i ; : : ; r ; � ; : : ; i � : i ; r i : i ; ��� : T I : I : ; � : : i i ; I I'll, ! I i ; i i .-.--..- .----.-.1.-. 1-1-......... . 4 +q�� ; I I i I i I ; : : . ; . i I I I I : I ; : : ; ; r ; i i i I � - . . ; t....; ; � ; ; ; : ; I I : : --.""----/ Fax:631.750.2744 I I ; i i . I ; i : ; ; � : : I i ; i ; I I r ../ I . , , � - .............. - ..---, : , ; ; I i ; : i i : / ,; i .......I.............I : � i i I i ; ; i i ; i i : i : tangelengineering.com - : I � � ; ; ; i I i : � . i I � i r -//-1 --I T i ", i ; " ! . . i r ; : i i IP11:1r; � ; : : / : N/L .. : ; i I ; : i . 5 11 i i i 4 ; . : : i ; ; : : ; : I : i i . z i 5 i 5 . MA VATION �! I I ` 11 i :; �/ , , , i ; I ; i 1 I . : ; . i ! i i : � 5 1 5 . & . . I i:ir I / i ; / i i .1................................i........�.............. -1-1.......I -.... I- 1- I I. .......... �...........I...........--.......... .... ...................I.....................................................�.........�.................. ,-.--.-I...........................................---l-... ....................-1-...11- ; ............. ----. .,------ - -----......---! � I -i -� ..........................- i : ; � i; � * ** I : i : i r � ... � i : � ; .-I.-......I......... Il- - : ; i i ; i � 1. : ; : i i : I j : 0 i i : ! I [ i ; ; i i: : : : i : i i ; . I i i : : i ; : : . : : ; .: ..... . i ; : ; ! ; i : ; N ;: i : : : : i : i : i i I i '... I ; i i ;. I i 11 i � 11 : � ; i i i ; I I : : � ,ii :: i i : i ; I � : ; i I j ; !I : i 11 : : i i : I i .. . I i , : : . .1 f I i i : , i i I � --- - ii 11.1...-.....--l'-�--1. ...........- i i i i ! I i 1 - I � � I I ;---�-­- �----------'-"- i J.......................- : ! ; . i i I -------------- i : i i ; ; i : j " i : � i �, I i i : ; i : : : � : i : : : I : : ; i : . . i : :: � i ; : 1 ! i i i � i i ; I I I ! This drawing has been prepared for the : : i : i i i i � i : i : ; ; 1. i I ; !: . 11 i ; ; : � - I I i ! : : i I i : ' I i : ; -----.I-.----- H I : i � , � --`:r� ' i I i i , : � , 1 : ; � ..i., . . -- �- i 1. .--.....--:�................... . I......... ...... ..................�.....�------- - � i - -1 . . i ;. r : ..--...... ............---- - 4 .I.I.............. ! =�-. - : i I I ; 1 t-,-- ......................:_:.,.::1-- : : i I...I........� .............. i I .................--I. ............ , I ,, , ......................I.......--.. ..... ......................................... . . � i � I � � : : z . . , .1-....... ......I..:....I.1. . i 4 1 i ; � : ! ! I : I : : ! i : i i : i . ! : : i ; I : i T i � I : I i ; i ; : � i i i : � i �,.. $P 1 i , ; ; ; ; I i , / , I i i ; : . : --...--.J................�....�..............�...� . service copyrighted by Mancini Architecture '/ : � . : : ; ; i i . f ; , V! i r � I :1 i� j /.��', / � I i i I i i i i � i ; � i N/L i ! � , I I - i z I I I i I . : . z rl,,'--,.'./......�/,��,-Z.,/�,,.Z.,.-',�z]�,,,,w/ z=��Z/z 2---. I ; i 1. -�...................t--*------*.- .... - ...."I - -f- --------- - . .. z: - , 1 ; 1; i...-I---..- ......... I- - I i ...,........� 'i I ....I......�.....�.... -....-". J I "' .: 5 1 1 : - : : i: i / : I / I � : . 1 2 : ! , : ;. 1 15 !!/ :......I- ..... .. .. I.................i..................... i , ! : � . I , , I I _I_ ,_- . : - , 4i -- i i i ..I I . . I ..............i ...---...-....".. : I I 9 I/ : --- -------.1- ii I � ---!-- .................. i I : .. ................................................----......., - ......r�111 DIM* indicated project and is an instrument of . Ili � i . I : , , �����.-.-"�.'..�:�..����l�.-.��������, , - I I r I . , 1 7 . .... 11 7- .---......�.......... r : ;; i ., - , i : : : : i : 7' ' ' i . : i : : : ; . /. -: �%,. .1 : : i //..//;; --- : , / ...".. !�:F2 7 . : 1. . : I i : , * 7,Z-,*Z`�*-""/' �/./Z./.Z/-1 .. ...../X z//'/7*"*Z' ��,.,/�/"�*/�*"`��`�:`/�`�"��`/"�`�`-`�` ,117111.'ZZ=71�1, � i PLLC. This drawing may not be copied or ; : i : I I I Z *� � W . i ,,� . I . ; V : -.,/Z, ../. i � �."/.-I r 1 7' i // : 1/1.... ... �z ; i ...1-1i 7 J -------- --................I.......-,--" I i [................... r --- ---- : Z 4: , z Z z /�? � (9, �K-�--� Z i--.-�.......z::-/1//zZZ///.Z//--. - �=........ - --. /.."/`�`��­­"`���`-.Ji-�.�:�.:.:::::.::::::.� 1�lz , .. 7 : : ,::..�-,::,-,-.�:_-�:,�:.-.:.:4���I ,��ZZ7,1Z.... =Z7, :/1" ! ; : I � : : i . I .'.. I i �/. i, 1 I I : I ; ! 1 ; ; .i I : : : i ; : : . : ; ; ................................ .........................--..........I.----...I.f . -11.1.1.....I . . ; : -I. I-- I "........- , � I i . : / . .......1.............................. . . .. : : . : . : , ��, i i , q ; i : i ; .... : . . i i � : � , i � ; i i i : � . ". -i...... i - . ': .. .. : used, in whole or in part, by any party without : : : .. ! : ; : ; : ; : : . . . ; ; i i I...! ..$i.... ... i ; /, : i � V. !1 1 �, - ... . ...... . ���1:�................................. ...............................�...j....�...............................L $ ; //1............. . ; : : : : ; $ : : : r : .;... i 4)2 1 . : . ; : � : i i/ : : i i . ; : I I I ; � : , - " ­­­­ ; , I i i : ; : : : : i : ; � i : i t ,1 . i i ; , ; ; : ; � i r i : : I ; : : i r ; ; , i i i I ...... .......------.\.... .........-111-1.1...I-- I i : : I i i I : : ; , : : z : a f* I : i . 1 5 i : I i i . : i I . 1. the expressed written consent of Mancini : ! : 5 : : : � I i I , i i ; 1* ** "", : : I - 1-1--- . : ; , : i 1 : i : I . `J t i : � : : i . ; � I i . : .. I � .-� . --- -..................- /: : i : : I k:..Li:y. 1- - : I i �� I . i , ! I : � i vi " : : I/ -...................--.....................�...-.1. I.........................i 5- "; 5 11.......-- .1. -11-1.1 i -I 11-1.1-111.1.11 : i i ; : : I : . : , i : t ; j i : : i i ; I : Architecture PLLC. Infringements or any use i i i/ ! .. / I i I I i Q1,t"m-W4�-) : r i 5 : I i 5 i H i / i i I . : , ;/ /I . i ; �-- .......I......I. V, i I . �, !i i , \ / ...................................--...--- I i .1 11-1.1 i ......................... ...�i . . .... i 5 , 1 : . : t � 1 �� i : i : I...I--......-.. i .......I.....-........-1.11 I...I-'... 1-1.1-1-1......--......... : : : : I . . i /ir ... : * ;, : / ; : � * /'� / - : : i i .1.11. : i I : : : : �// I-kl;:-i i. . ; . : . : .i'�zz*�1.17 /./,.Z /ZZ. Z-,//,,. : ! .1...1.111, ; I : . . : . i ! I : t : : I / t . : : �� ..............................I / b 5 b � 0 this drawing for any other purposes will be � : ...:/ � : ............ :i t i; / 5 � I; ; " 1 , .1-11.1...--......... ' i :: : !, ; ..--............... ......... i : i . : : ........................................... t ; i /�/` '! � . .......-......... . I/I � � . 'i I : " ,/, / 1. C1 ; i .. 1.... .. .---�/ : : � --, 3 5 i ,4........*...... . .......*---*----- i �.: .-1--.*-- 'i I 0 i : �---; - ! . : : i .. i . V . .. . I prosecuted to the ful!extend of criminal law H : I " : : ............................ ................-...---+� : I V .I i r � i : ! ; . : ;; i r OFFICE MA*S11ATIOI`*1*`*.......... "" " /1 � I ./ I ----- i "I --.. ..... /I . . 2#12+C7, 514"C, I ! : . : ! 'i � - . : ..........��, / ��.................... .................... ......................... : i i : I i : ! /) X .....RECEPTION i 11v : ! . ; ; � � " � i i i ; i I ! � : . I -- -....... 1! � 1 .11................�......I......I ...............I................ --- -- �ED ROOM , , /. t ; : . �� t � . ; I . .- -I..i:.- ...., ,� I . : 1. i : ; i : --- /-TO LP-I illi : . . -1. I ! : ; : .. .... ; : : : � MA S; ATION I Do 1 - : � . ; ; : ; : ., // / : : I . //,- . ; � I : ! 11 .. : ... X : . �� - � t +/ I �/-. ; I - I ,-.- -� - : j . I : 1-n I : ; , ! ; . . ; ! . ..t.................. . ..... ; .......................... 1-1 ......---.......... ; i EXAM i i : � I -.1 - 11 '13 , � - + 11 / I EXAM i � I..............i i :! ; : . i I .............. M /� : i : ... ^1 : / // -....---..i i .:: i : . /I i 5 �i - : r .........I- I 1; /�l 1, ih***6* , , . : : I ; : i i i ; I - I - : . t : : 1-1........................ I........ . ; : I i t : i i I ; ........ .. - i : � .... . : / i � : /-1 ; . I , '51 �................................�...... :,;� 5 i �� , � . : : +/1 - I t, -t�-.., .-J. I : 7 I . / I : ; r i i / : I i : . ; 1 : i : i : : ; : r-,....I-�- I I i i : : : � i : i -.-......:, .111.1---..........i I I' I i i : : . � ; i i : . I i 1. .1 .1 ............... . I - // , i . : ; i i : . ; //� I/ .........................................�............... ......................... ....�...---.---------............. KEY PLAN + i : i , . I i i - 1. -............-........ . i "- !i !I. --.........I .... / " - - i ... .... ........................./ 1 i n�. 1 105 ; + i i : i I i : r i I i ; : : i i . : : : i � ; �/,, � 1/1 - / ; I- i : . i i : : ............. � I/I z : '/1 i /11 I i i ...............t ................................. ._.._....____.___._.__.. -,9.4�-%,�- 1 !; ; : . i E AM OEG@ 1 P ; ; ; . ; i/ i . s : i i ! . t : : ; i : I .................................. : i �i , ..... . .-............I........- - -...............;...........11- 1 ....f.......................-- : / i : // --- � . ! - k i : i i . � : , . : ; I ; : i I i i ; : ; : . / . ...............;-- : *. - I ! z ��l --'- . : i ; : i i ; i ; i r : : ; 1, t ::; i - : ; . : i i i : : I i : : ; . t / + I : : : . � - i ; i �� - : 5 ; . l 7FN E tMq-/� - : ; : : - / I :� : 126 OC-0 i i .... , i ;/ : � ,, -./;/�/� ! �� 2 r ' A . i -// I , : , ; i : I i . . . i il- , --..---.--.- ....-I .... ...� � -- -................. j_ i '. - - �-...�.-�,f-...:;":�-�ll.�.11I.",,.",,..i",..", ....... ��...-� ---.....J 1111-11...11-1..........;.. ........ ....T........--.-.....- - --.- �.-------------- -- : ..,I ----I -1 ,( . I - ........111-1 -1..... ...li, -.. - - - ...... I..".., ................I...=...... I 1- - , i I ................. -...- .. -.1....................I I-- 11-11 11-11,........I...I...... : --. ---- V1 � r � � I 1, , ------/ -- - -- - I-,-..---14 ----------: .--- , ,� ......: --...---.- .. 1-111. . -- �.--,...-..........1.1-11...i ...., . : i -- : i --7-- - ........�.....I........ -�I--.- : r I ---�-1 - --- - - ; i : i i � . / 1 . ; : I...I i j . . .----- "C z I : : i . I : ! ! --� - --- - -- -- --- -- --------------- ----- ------- : -\ r ; : : . / i ................................... . . - : -- . � : HP 0 : : ! : 7 ; I : i -- ..... : ; , . i - 1-11 i . 1.11,11�,11 : i � 5 5 : //) -.......... � I---.,::.'4 :: i i ..... - . : t I . - i I - i . ; i t � .� . . �� --I ) : i . : � .!,?/.,.,z Z- /:� -/." 'J � I �� � i i 5 � 5 7 "', :k',(\' , i . : . : i i ; i .. .I I....- ..�/ : i / ! i Z/z1/7//7///'/Z-ZZ Z' " . i :....I 11--...........-.// ............................ / � 11�� ; - ; : � i . : r ; : i . i i ...1.1- ; .........I ... I i : . . i ; 1 J_.:--:.i; - :; � i i : i ..-.............................. I......................�........�............................. ..............---.-. .N ! . I : r 1 i : .................... *..............­ I ; I 1. 11" 1/, i!,i�. : : ; : , . i : i �11 : : I I i :., . . I : , . i "1 t -..........�........;........................ -..............I....... I I . . -+/� ; � ; i -J I i . ; ! : i i . ; . / . . :p; I ; I I i . r i � i V i , : I , , U 5 c I , : I ...�....-...--....�-.1--, � I / '"'"'*, , ," ..... � i i b - ,/. i /. �P �41/ i : lr� I I I . i . �A 5 : i �� ': r .;!�� , " () : ; ; i i : r i � I : : . ; . : : - �! : : : � ; I . : I :1 i , pt k"', ; �// : : : ; �i :---....-...--.-- --+- -11-1-111A � � I i .,6- : - I -................. -�`;-I : : .. .1 ; :; - "� �, : . . ; i;i : : ! .......i , - - I... i : ; "', : . : :i: MTERPROOF W ,- C. 11 I -,-� I i ""I / I , i: ; s . -1-11 I . .. �/,.- - + .1-1....... .......... .... - I : ; ; . .�,, i : : ; . -, ; � i "I, : / . r- . : : i I / / .A-;1,---. - , ��,- ; i ; / : I : i , �Q4 1 ; it i .,� I. : : r // - ; , i : C1 : r- I , : i : -.............................. -0/4 11 r,:,1 / � 5 5 : / 11�,..--.. ..........1�................................. b b � ; / ,I �//i ; : r i - . ; F1 1 � . i h , i . . �� . / : i C1 , I : . ; ;!! 5 �,, l;),��g, 4 . �:i: � I i -........'L..J . v, . a i JANITQ�- I I vl,, I : i� / � ..............................--l-1--.14 - �i � . i i : / I! r 1 ;1.....I.... . ; cr_ i . ! � 1 i ! I.........11.................... 1 ,i ; : -JUNCTION 13OX I : i . : ; . ................. ....--+-................ : I i I : ; : I I � t � I - *� ';: �1 LJ I I L /�/1 i � I : H r i I j, / I � .... t . I - . . , , I r : i : I ; : � . ., .; I I ! i i X ; � : : s 124,,� ,�l ! �........................ . ; � � / I.... - --�--..----...-....-.---........- .--.-. .1 LIJ i , .. I I �...........�...........I........4...................�...... ; : I . . ;�/i �-1-I I I I ; i� V! . � ; z : �/................. ... .. . -.--"-. 11 ii i ; I : : ! : * .. ­- FOR. OUTDOOR I -- � I . i : : . .: .� I t I / : ; : i I i i � !I ,�,. ! i � I i - -,--,--'-**-­­-, ,­­ TT- I ; I : : /I i : i ; 11 i i i : . . r : [I., i : i A i 1�� : : V �; , . i " ./ . :,. ­ i "-- - .i . : i i I I V : I '.. i ! ......�...........-- ,- 114 I* - ; : i I i - i - : : I . . , / . i...1 . , I . ! -. : t :11 I -- I......--� . i ----1..................................5-DIM., ----i .."', ,� : . . i . I z �-, 'I, -11 : i ; . : I---.....� ---....��.....-1"1 1 ; ;. . . t 1 ; : : i : . ! * - .1i : ! . ,-� i I ,/A...........I.....................................--- - ............ -411-1.1111-.......... !;�, :� � : i I ; i . ; i : . I 516NA6E. 0IR0JIT 03 '. -1 i i : : . i I I . � -!� ! ; >.& t ! : 11" � : ; i ; : i i ;..............I... .. .......------....-....�.........�.......�.... .I ; I ,�4! i i 1 �/+ j ; - .:.`,-.::,-- i . 0'...- .. ...- - - - - .1 . ................................ ...........� i / : i /1 I , ; i :� . i : . : ...I.............I...........1-1.1 .-I......... I /, : T ; ; ; - . .�� �/ : . i :: a ; i ! i 1 i ; ! i : I ; i + r4 i i i : i ; r i . i I : i ! I - - i q i . ; ; I -, 1 . , I ; 1 1 . I 6 ' -- , : ; -............-11,I � I I . . . $ '! . 1 i : � /, i $ V/ $ ii, ; . , i I i i TO A%UTOMATIC ; . . , I � : . i ; .....1. . I I V ! ., -111 . I "" .- - r r ***+ : ! ; - ; /,/Z��//--/--/--: : '"" "/ ";/// I"��� . ZZ ....".... -.-..--..-./........- ...... .. -----1 77121 7 ---------.- --------L I i - 11 . - r ii I :� : . i I ; ----7--"-'----- : : : z -.---- i � i- - - I j ; i i . i : i i i - 11 ; : : : i I/ - : : =/�7'7' i "/-/ZZ-2Z.; �I,"-- ; -�. ' -�..-,. 4. + * , , I � i .. . .....I.....................-..-.--.-.--.....-.... ... ," . , i----.........- / , - - ....... - . . �'.j- ��/////-- - , � ,b /./`z../`­­�`­`; 0,;//. Ir //// , I �� . I��/,:Z, �� z , '.� 'I,-Z, "" Z" 7*,��!7/*-... "R, i I i : .. ,, �=Z///,Zzz I -z ,: I / z....Z../1,z Z 7' ZZI ////--////..- . �z-e Z z�/Z,�Z L, . - 11�5�,/,///"/� :::*,Kllzl,�,,IZ�� / :r - ,IZ/ A ,� . I... I r r ; i i �Z-/-Z*��*�.�V/, --..- 51141 TCH : � i ; ; ! i i � i : i I � . i : : : ; : ; i � i I ; ; . i . : �'�i i : � I i i ; i : I i � 1 1 17--= -I.::, / : � ; � i i � I . I � : i i � ; � i i ! i i i*t== .-.­.---.. ! s S k 0�4, 1 i : i � i I i ........- - i ; I i j MgL/, ; 5 i i � 5 ! 1 5 d : i i i 5 5 5 : i t : : i - ; . I i I I I I : 5 i I !� : I � i I--1. .......I..............I.... .. .. . .......................................i..................1...I......... -..........I..........................................,---.; ...I.-.11111".. ............I ; ! I i : TC, � .- .-� . I.- .: � i I : r...................I..............I..................... ....,..................- i : ; � --..- f . . ; I I - . . .................................... -----............1................................................................... �.....I-.1.---.1.. ; I j : . I i i 11 S : ; 1. I I � � � i ; ; i �, i , . / .1-----------------------.-,. I .. I i � . I ...--�111.�I.-+ --....�... � ........................� : : i i : i : i i ! � i : : j .................i : : I ! : i : I i 1 t : --l""", �4:� i i I : : i I .,I : ; -� : .---.....................................�l I i i i ....... i : � i i � i I i ! i ! ! i : I i i i i/ : i. ! I ; i i ; i i i i i ; i� . i "" : i : i : i L, . if i ; i i i ; i i i : i i i i ; i --------------- i i I ; : .. ! * : . ; i � : i i i ; : ! I i i i : i : i I I I i (9 i ; . i - t- ; ! i . . ! i ; �- i � ; ; . i i i : ; : i i ID i b i i 111------ : t � : i i . i : i i I i .� �,�rr i I ; � i i ol ! I ; r : i : . I i ; :: �-21 � i // i � ; � ; i i � - ` ! 4 1 1 ; ---------- /i 7 � I , i 1�i : I ; : � i , I i i ,- -�-,�,. .............I............ I ; . . : ; ; i .. .. I r ­.- ; i : : i .......... .......1--.1-1.....I... .. ..''............-.....I --+--I+�........�................ I � ................... -i--.- ---.................................... ............................... ......... : ; : ; ............11 : . : ; I . . .. ...- --.- / i ; : :; i i i -,......................... ....................................................... -.... I.: i !-...... I ............. ;: , i I 11 I . I I : i i . : ---..................�........................ ----- , , , , , ;.......... I ..........................0- : ; ". .1...I.- : ! i ; : : i i � i i : ; i i : : ; i :: -.. . ..........�. -+�.........V-1.� I-- I i i \ :: I - I i ; i ! i ! i -"'// : i :: i i i r i i ! z � : N/L ' ; i : i : i 1 i ; I : � : : � � ! : : ! ! ; I i :i ; i : : . i ! : I � 5 i I :i i I i : i I i I � 1 4 i i I i � : i : i ! . � : ; : ;i I 7EA7 1�071 ++ i i ! ...I.- 0 ! I i ; i : i ; .. r I : : ;; ; . I i ! ; i I i 5 i I \ i i : ; : i ; . ; $ I.---- I i ; i i I i : i i I ; I I ! i I ; .1 . - i --- : I ---- --I------,- ; ; I i : i i ; I I i F.- i i . ; . ! i A h, I r i ; : ; I I : : r r i ; i i : : i ; i i -4 :::- ; :. I : : i ; ; i Ji . 1 . I ; r I i : � i .. ; : � ; ; i ; I i I : : 1_11$ : ; I i 1-1.11-14--.1.1111-1............-If.....I ! I � I I i . i I i .1 : i .... ; . I : : .1 :1 ! - � .i ; i � : � � I i I i ! .1 : i ; ; t I J I I i J . : I � f .T. i: i ; ; : i... . ; i : i i ; i i I.... I :: ; � �/_: I .1.......................... V.f� . 1 . . ..............L . . r ; ; , _. ��./. ........................ ....�....-T ...... -.1 ".. 1 . - --...--.-,.-.- .. � - /1. .. 11 : i r . .....-t.-......................... .........................�............. I I +I ,* - ;� C1 i 43 i�I r� . ; , 17 1� ....... - i/, ?, ...... ,1� ... --- ........ --- ;; . : / 1 t :17...... I i ;I :. r -11-1..................... 'Ir 'i - / ,/ ; I �.1; ,��/////,, i z///////,/Z.7,/... ...Al �,/-/.--,/`�` .. :I I -/. -�.//,.//. I-- Z. A . f / / � �.1-��........ $i� i �//,//Z/'//////////// ,�'��/f..ZI.71 �Y, i : i i I . i I r :. - , . //,�z - .". . . - I . ; . ; r, , i i !11 : , r i ; : ; � . : i I i � i i PROJECT ; ! r ; I � ; : . i ; I ; I ; I I .--..--..-.. -- . ; : : : " I . :. i � r ; � : ; i i . . . i � r ; . 1, i 1 � : i I ; ; : : I I i . : 11 . i : ; i 11 : I : I . i ; I : \ � i. I i I ; i \ i T ; : i : I i: A ; : I'll I 1 : : ; I ! I : : I ! ; : � .. : :1 1 DIM.' I I : ! ; ; ; � : I I � ��11. :; ; i i I ] : i / ; i ; I ; , --' r$ 51, j� ; r '�' I � i/ I i I I� . � "/.....** +1/-, I; ,z Z I .... ....222z. ; i : : I i i i i �7......Z/./..`/**---/-`- -,.:.......�I...-........ -/ 1 zi ZZ, i� � //1+1 -......I.............lz� Z' //- r , �`� V/ i : -1 i � � - * ,,:, ,-1 --/+ : 1., /'), , / /,- , "'7� ..............r...I I -Z---,�/Z, ��, P Z// . Z.21Z' Z�Z z... :+-- - ZZZZ 7�� /� Z., Z�3/--"�`-`2`�-`,"/Z.-...---- I ... i�� I / ! i i................ ; ; �� : -...I.. ..I 11.1 .1, -T.................... ...... ; 1.11: I .1 11-1,1 ..I . .I-- - - -... -...... ............... .. -t 1-1--..................................4.... ---.----.................................../i /1� ; . I...1-1-11..................?--......I---I......... ..................�........t, ....�....................k......... ; . . �--..-.................;-.1.......I......-;..........$�.........I--........ �/ � �, -- : ...-............t� . - -.............---- , .'t-..---- : -1..................I....I........-- .- - ii I I ; i I I : I I ; �: 11 ; ,; . ; i /i ii . ; i ; /. . i � 11 �/,---...--, ---.$I,. -----,-,I- -------*---,---", !i ; i % :; i : , � : - ----l------ --- I ;r . I i p I �i 1 i :: i t ; 0 i. , . � .. ......... �� I �. i i ;,� i I :r 11 <' : 411 H � i !11 i , i 11 � :I j ill : : I I : 4 , . 1/1 I : : ; i ; i ! 1 11 : : I ; : \ I �� I I / ;t I I I i I ,� ; i . ! ; I i I I i j i V / : t ;r 11--: ; i i ; 0-1 . : I 11 i hil "PHLEBOTOMY :: :. I / : / i I !/� 11 1/, 1 1� �i I ��. I i . . I i STONY BROOK ; i ; I ; ; L :: . : .f / ; ; ! �1, � : I \ ; . ; .. .......i - - -... -- , . i \ i I / : ...--- ......., .....-1.. . -.11.1-.... .......................�..............-......:-+ :z :i / r . i + I i \'� ..... -- : H : / - ; : ; i I .. . . d- . :� i - : ; i � ; : � ; . : i : I i . ;: V .: ; �/11 : / i � I i I : !1 1/1 ! / I M I i\ /I : I 1 i . I ; i i ; . i / r : : t z . . ; : .... - I........ +;: I I f I : 1 �� ... ; I // I i � / " i A � - .... .......... -- ; T I I t i � i J** ii 1 r / ; i ; ! ; ii . i�4 I : ; I : -..... ; . /i-1................ / r . I : I i ...."111-11....... !I'll.-/ , I --,�.....�, �.....�:i �........�11........... 1......1-1-1-1.11- .....-V.......i.......-- I i . --,-..---.-----.-.---.-.,.-....--- ; I : : i : , : I I . ! - : ; i : � i 1 : il I ; : :i �r : i I ; : i : "" �.... ....... --/ i : r : i i i : -, : ;i .;-1........... i ; : -.11 A 1.1- - --- i 11,... ...� : i ... i � i ; : I i . ; I t i - .1. : i 1 � i < ; i /; ; i / : I ; i ; . . i . : 211 , / : /. ; ! ; *��/., * * * I / i r � I 1: :; AB !i /,. I ....-......-1.7...1. : I ; : � �/,.--.................. .......I--1-11-1. ......".1.111 r rAPF- I ; /. - ------�,/ /I � i ; j i : i ; , , ... 1. - - .... /.......................�......� ......�.--,.,�-.---. , ! i C.... . I t i . , : - j, I 11 11 , I -- ; ; r : 1 1 - I- i , �-. i :: -1 ­ ---- , t...........; � .-i-i 1/1, I+--- - : � i I ---t I i : I I : 1 ��, - : . - : MEDICAL : . , i t : : � i ; : ; ! a � i ; i i 4 1 . . : 1- -11.11 i : ! . ! t ; : I WAITING : i r i : i i : : i / i : i : ; : : I i 5 ; I i i 'I'll' i ,/ I i I : I I : : I : : i ; i I i I : i ! .... I i ............................:1.1...........--. ...1-1-1-1................ ...I...�......-..... �� �: � : I +�,. . : ; 5 /i . I .... -.--.../ �.K ;�/i' i�.....� � I// /.1 10095 MAIN ROAD i i : I ... -�, I i J.......------1 / ! ; , � ; I t i i . ... U. . . : i : -, i . �- EXAM EMM i EXA EXAM ; 5 I .i i t : ;. . : ill I i . I � I . I : I I I I ; I : i i :1.\\\ � ,; ; i 'i i .-....I.......... .. --- ! i .11, , I , z : A ; . �! /I I T . // 5 ! L i ......�...-..............�......�...... .1... i i i �4 I ��b : . + I ---.. ------.---...--- I ! � i....1-11-11---,...� ...........,, i ;.I.-............................... I .............................-. -.1-1-1.....111. . ---- �..... .-.................. 1. 11.1--- ..- ...........,...............I .- -.-----I........---............---/ -........��.........................- ................................. ........-..---.-.. --- J I i : i i - . ...11 : : I ,,------,---- --"---- �i�v ---.1-1.�/, - ------ -- : MATTITUCK, NY 11952 ; i : : I , : i : . � ie-i L I . . i ; . I i : : I : i -... .I-,'- i i i ; i i i --�.l if-.-......I...1: 1 --47- -....i ! I i I i ; : i . : /; : . i i ; ! . i ; i ; . ; i I ; : I I I b /+1 : : . . : �/l -.....+..-.-� I . , b t ; ; ; lz A, I'll , --­-*.... ��, : i �/. : � : . : i i : : : : : I � ; I ; : : ;�'. r �//. I I i : : i ; ; : . : : ; : : ; ; ; : : i F : : 149 1 i , : : 0 ; `//1 I i �---- : � i I I : ; " . I : : : i C11 : L i : I ". � --�I ....... / 1 : i - 1 '13 -YN : a I I r ! : : ; . M / - ; : --....--...---� - .-- ; , I ; : i 1�1 i " I i I / I �, � : I � I �, - . . EXP @) ; t ; . I :: : i i ; ; i T i 'I . � ;(t��ew, r �-1 : i : V - - - I i : ./It B i'HROJ , � I I � I : � I : DRAWING TITLE i I : : I I: _ ..// i ; I : i ! ; I i ; : . . : r -... - - -....-/-......--.11.1...- ............................... ........ ---- - : i -�--.- .1 .. : / ; //4 ;I.........................---... �1............. I ........L............... , - --L I , ";............... - .....�........--.....-- .� , ...�....�...- --�),** ** , - -- -1 i i i / - - : ; �: . , t ..... ..... / I - - i I ; ; . � ; 1: ; : +- i ; . ; : ; . ; ; 1: +/,? I�-, , : ----------- . i : ') z . ; ; . ? It � : ; : i i ! i I/ . ; 1: : . : �� / : I : ; :: � i � I : ?... i ; :: : , " I i ; : ; i i ! � i . .-.....; /i : � : : ! ; : :: : : i : � : ; ; t ; : 1: : . I : ; : : ; I r I ; ;: : i ; j ! . i 7 r ; : :: : : I + /-1 � i I . De I � I I i i : . V. - /-1l a i : : ; i �� j I : . i i I ��........ � : ;: : ; . -.. , i : : j ; 4 . ------T- :�C` i i i 1� : i i ; ; �r : . I\,",\, i I i /I ; i i i : / , I i : I i " /1 ; i . I _ _ ........-.... ............ : : I I . . �..........�..........�..........I..... ...........................1..........................I�1 .........--- - ... .,.................- I ; . : r ; r; : ; I i : t " : : i : I , '�/r ; : i .......1.....1-1..............I....... - i i . ! ; ; ;: � ; i . i � . i . I ; i / ��. 1 1 i I /11 i i i I I i : : : :: : I : i i : i : . ; ; ; : i � :: . : �� : �/� I I i ELECTRICAL LIGHTING ; : I . ---.-... , : r.....I-- ..........I.................I......... / ...... .-.-. .------- I I : � I ..............-.-.---,-..//-...-- .--,. - ,--.-------- � . . i ..........F--.-- . i .............. �,.......I.................... ......................... � ; i:.............................. ...............................:. ... -- � ....---...---....�..... "", . . ..--I-- -........ i i .......V I-�.........---------- ; i . : I � ...-----'-'----r , i I i : i ---- . � I - -.--.i ....�..................�....... i " , :: . . . I - - .. : /1 . i . . . 1 - . V/...............--.----- --I- . 1 i ...........: ...I .....; , .. ........�... ....../ ....... .- .........-1 I I I i i i . /. //1, I ; i 1 o . i . . 1 ,-------4,----,--,-,,,--,-,,, . . ......* r i ! I i I ; : : : i i : I . : I ! . i I . . . I I t,/f . i i . : � � : i * . i ,/ " : i I . : i : i : I t : i : ; i i ; i T i i : i t i : I I ! : I i V I i ; I i . : : . i i �� I I ! : I ! I � ; � : : : ; . . i ; i � : � I /I I : ; : � ; . i ! � I : : H I I i I * i ; � : PLAN * ! i i I I i ! : ; ; ; i I 1 'O"W" i . i : : � r i : ; f . : i i i i � i : ; i : i . : I � i I i i ; : z ; i i ; i ;: : ; . i ,/i I I / �" 1 i i : ; i : I . i : ;: : : i � � : : : . : : i i 7 ; � : ; ; : : i I :� : ! ; ; T i : . : I : . I I 1. ..-.----.....r . .. 4 :...-I I i i i : : : I : , : : : : i ; ; i i i ; : i : : ; : . i : i . f i...4-1... T : .0, i I �/. i I : ; f i i i i . . . j : : I ; ; ;1 t I : ; : . : I i ; : I I ; I i I I : : i : . : ; i i i i s i : . i � . : . : - ; I i : . I i : i i ! I i ; I - -1............ -........--.1........�..................................1111...I..........................;1--+-....- 1� .......� i ; . .11-1.1-11.1...�...11 -I ....---- - I-- I --�- L.--�- � I .I--- I I I -+ -...... -I s. -1.11.1................. --;................. I .........i......................................-.21 1 i , i I ...-l- -.----.--............ : ,-=-:+-::*7����--�........-.. I ---, , -1 1-1--.1 -.....-.7::-;7.;7.�.-: �� r,j r 111�� �:+:.� ! I -.-----------.-----I.........................--- ! .-.... . . . ; vi i . . . ;i , : . : I : ; ,/ i ! 1 1 i r,.,,n : : K� � i 1 . �/// .............. .. I I..."....-.... I.......: . /�. � � '/ /. I - I I ....................I........... ; I �.......-. ..........- .-I.I.I... .i . i . � i i I � I � i i � I .........................Ll....I- ............-.........1---.....�.................i..... ................................. L - 1. -...:/..................--.... -.1 - - , ........1�........ --.] ................�/............1-...I �---. - - , �: -....--I-----... .... .- ..........--- ..................--------...................I.............�............. . ....I...�.... ................. --............ - ;�� .. j:..�.. ..- J r, +- . ' - , �........................ . : .1 .��­�;7/ -�.. ] -- :,::....��-�:�,-. �!,i 1 �! i'� - .7.:.:.- *.:�A, ��, - -111 I ;; . :-: ,:. I.: ,-, -:.......... , 1-1 11 '. ,.,-17 ...111-111 . � ' 71 , =. ....... + �� - - . I' ll , �F,11 --l- "Ill , -:.. ;;� I -- .. i: .. - ...I......................�.....-++-....-....-.: . .- I . .I...."... I . ".. - ..--.- -;- . .�i..-.. I--I......I......�..........:..... �:I--...­ ,+,I I :. , . : 4q ; I -.....I.-...................... . �2 : - P I i I I-:...........--i; :i , � i I �1 , i . : :: , I.... ..., :--- ....I.......11................................--.........................---.................. . .I--..... ---.....---....... .. � ........ ..... ........-......11.....- . . . . .... . " . ........ ...-.. .............................-I...I---I........-...........I....................�...............�..........................................................................--.....-..-.---........................-..--,....�........--...-.....--------.....................-.1-1-1......................................................................................--...........................................................................................�......................--............-...-......................�............................................................................................................�...........................-11......I............................................................................. -- .1 :1 . ...............---. I :1 ; : s: I � s I � : !I I i ; 1: I � SCALE AS SHOWN : : I � I : ! I : .! NOTES: i: I : i I / I I i i : : / I DRAWN BY ; 1: / 1. ALL EXIT LIC7HTS SHALL BE CIRCUITED TO LP-1, V7 (2#12+6, 5/4"C) ARC - ; :i , I ; ;: I - 110) :: ....""", 2. ALL EMERSENOY LIOHTS SHALL BE r,IPZUITM TO LP-I " (2#12+67, 5/4 : LA.---- r DRAWN FOR TET ; ; i 5. N/L VES16NATE5 UN5PqIT0HED NI&HTLIC7HT TO BE ON 24/1. i I r I I I : 4. ALL L[CPHT FIXTURZ-5 IN ENOLOSED ROOMS SHALL BE C,ONTROLLED BY A CHECKED BY TET ; ; ; i : $ � KALL MOUNTED OCX,UPANCY SENSINC7 SKITCH : : : : t PROJECT# i 20-021 : i 5. ALL LIC7HT FIXTURE5 IN OPEN AREAS AND CORRIDORS (Lli #5) SHALL BE i I : z I CONTROLLED BY AN A500 5V41TCH A 24HRV'MAY FRO&RAMMABLE DATE --/--/---- : : i : ! : TIMEOLOOK. A MANUAL MOMENTARY ROOKER 5PqITC,H SHALL ArOT AS A I : : : : : : : . I SHEET NO. i ! � TIMEOLOCK OVERRIDE TO ENER61ZE LIC7HTS AFTER HOURS. I I I "I E-1 02 0 C " ( , - C "', 1 7,7 ! I : : : [:: T i I I : i I i br i I/ i 1 1 .� : P : r_. i : : : : : i : i � . i I i I. Ll I I A"""A I N"', 1 1<y (D ; ; I ; // �/, /// //1 11 I i � i i I I i 7Y- i i I i I I 0 �: 0 1 1 1 1 - I A & I �/), � -- .V/ � I 1:-- K N��� 1 / '0� . i : i 0 i I ! -0 d � / i I X : // i �/, I i i i i I ! /� ; i i . E, I 0 ,� I I E : i . : � ,,,, Z : I i I i � , vl I [�-;,-J/, r�', � = Z-�, - -��/, i /Y-Z`/�.i;�/.`�/�Y-��/���`-Z�/��"`,"� , -- - El i i 1:; ; I i: i V 9P � i i ! ! � I i . ; I ---, ; ; : : i - : i I i I............... i i I -.0fl, ; i I A I E I I Leffj F I � I I I --------- 1 I i i � i I E:1 .�/, i i : : I ; / : : I i : i �. : i i : : : z : I i : : / : : 4 r z i z /� i i , . i ; . i � . : ' : '1\ '""] k, ! \ i ! �'E i I L 1EF- N I b 6 :IF.] F.] I �, I I E ii I 1�/, 1 � K. . to I Z r I I E I i , /I ! -- Z ! i i I � A2 i : I i ! : ; : �, i . I I i V � E-- /�/. i I I 1 i i I .i I : : i i 1 1 ) i i ! : : i I i 1�1 I : r* -;�-", 5 I � I � cs(%(r,��`-,� ; ; ; i I I i i � I I I I' - 1 GR I OUND FLOOR LIGHTING PLAN / 1/4 9 =1$-of$ . SHEET 2 OF 4 1 NO. REVISIONS DATE 1 ISSUED FOR REVIEW 5/12/2020 PANEL NAME: LP-1 (NEW) LOCATION: BREAK ROOM 118 AND COORDINATION 2 95% ISSUE 5/14/2020 TYPE: FLUSH OR SURFACE MOUNTED r—I20 VOLT FROM PANEL LP-I, *5 �20 VOLT FROM PANEL LP-I, #la �1 N H 3 COMPLETED 5/22/2020 SERVICE: VOLTAGE: 208 PHASE: 3 WIRE: 4 CONSTRUCTION SET PANEL AMP RATING: 200 MAIN OVERCURRENT PROTECTION: 150/3P BRANCH OVERCURRENT PROTECTION: CIRCUIT BREAKERS 4 COMPLETED 6/04/2020 MOMENTARY CONTACT TYPE MOMENTARY CONTACT TYPE 7-DAY TIME CLOCK TORK GAT, 't-DAY TIME CLOCK TORK GAT, CONSTRUCTION SET DESCRIPTION WATTS A WATTS B WATTS C BREAKER NO A B C NO BREAKER WATTS A WATTS B WATTS C DESCRIPTION #D6UM-100 #D6UM-100 5 COMPLETED 6/12/2020 LIGHTING 1160 20 1 2 40 2906 OF ON OF ON CONSTRUCTION SET LIGHTING 1140 20 3 4 2906 RTU-1 LIGHTING 1040 20 5 6 3P ffffi 2906 1 OVERRIDE SWITCH LEVITON # OVERRIDE SWITCH LEVITON # 6 ISSUED FOR PERMIT 7/07/2020 EXIT LIGHTS 80 20 7 8 40 2906 EMERGENCY LIGHTS 275 20 9 10 2906 RTU-2 ON —✓65'7-2W, FINAL SWITCH ON 65"1-2W, FINAL SWITCH -o ♦ LOCATION BY ARCHITECT. ♦ LOCATION BY ARCHITECT. TX-1 TX-2 TX-3 TX-4 EF-1 EF-2 150 20 11 12 3P 2906 0 WATER HEATER WH-1 HWF;P-1 200 20 13 14 40 2906 OFF JAN CLOSET GFCI 180 20 15 16 2906 RTU-3 OFF DRINKING FOUNTAIN GFCI 500 20 17 18 3P 2906 OUTDOOR SIGNAGE 20 19 20 20 0 111111111111A SPARE TO LP-I, #5 MECHANICALLY HELD L16HTIN6 AUTOMATIC SWITCH # TO LP-1 SPARE Q 20 21 22 20 0 SPARE AUTOMATIC, #la MECHANICALLY HELD LI6HTINO SWITCH #I SPARE 0 20 23 24 20 0 SPARE ON CONTRACTOR IN NEMA I ENCLOSURE ON CONTRACTOR IN NEMA I ENCLOSURE SPARE 0 20 25 26 20 0 SPARE G WITH 20A RATED, 120/27W 12 N.O. C WITH 20A RATED, 12012-MV 12 N.O. SPARE 0 20 27 28 ,20 0 SPARE CONTACTS ASCO 91-I SERIES OR SPARE 0 20 29 30 20 0 SPARE Oi= ��,1 APPROVED EQUAL O APPROVED EOUALaI'7 SERIES OR TO LIGHT 6 FIXTURES TO LIGHT 6 FIXTURES BLANK — — 31 32 M111111111A BLANK BLANK — — 33 34 — — BLANK BLANK — — 35 36 — — BLANK LANK — — 37 38 — — BLANK NOTE: ROUTE LIGHTING CIRCUITS NOTE: ROUTE LISHTINO CIRCUITS BLANK — — 39 40 — — BLANK ASCO SWITCH #1 CONTROLS ALL VIA THIS CONTRACTOR A5 ASCO SWITCH #2 CONTROLS VIA THIS CONTRACTOR AS BLANK 141 42 — — BLANK LI&HTIN6 ON PANEL LP-1 CIRCUIT# 5 NOTED. OUTDOOR S16NA6E NOTED. SUBTOTAL PHASE: A 1640 TOTAL PHASE A 10358 8718 SUBTOTAL PHASE A SUBTOTAL PHASE: B 1595 TOTAL PHASE B 10313 8718 SUBTOTAL PHASE BOPEN AREA LIGHTING CONTROL SCHEMATIC DI CRI�M 515NACE LIGHTINf CONTROL 5GHEMATIO MA 0 SUBTOTAL PHASE: C 2190 TOTAL PHASE Cl10898 8718 SUBTOTAL PHASE C (NOT TO SCALE) DIAGRAM OCINI TOTAL CONNECTED WATTS 31569 (NOT TO SCALE) MArN ARCHITECTURE PANEL NAME: LP-2 (NEW) LOCATION: BREAK ROOM 118 M U I CONSTRUCTION TYPE: FLUSH OR SURFACE 222 Middle Country Rd. Suite 314 Smithtown, NY 11787 SERVICE: VOLTAGE: 208 PHASE: 3 WIRE: 4 T: 631-979-0104 PANEL AMP RATING:: 200 MAIN OVERCURRENT PROTECTION: 150/30 BRANCH OVERCURRENT PROTECTION: CIRCUIT BREAKERS F: 631-979-3445 info@manciniarchitecture.com DESCRIPTION WATTS A WATTS B WATTS C BREAKER NO A B C NO BREAKER WATTS A WATTS B WATTS C DESCRIPTION SPARE 0 20 1 2 20 1260 GFCI 119 121 125 127 129 130 SPARE 0 20 3 4 20 1260 GFCI 103 105 106 107 108 109 SPARE 0 20 5 6 20 360 TV's 100 SPARE 0 20 7 8 20 720 GENL REC 100 SPARE 0 20 9 10 20 1440 GENL REC 127 128 129 130 SPARE 0 20 11 12 20 1440 GENL REC 119,121,125 SPARE 0 20 13 14 20 1440 GENL REC 101 103 106 107 109 SPARE 0 20 15 16 20 1440 GENL REC 105 108 136122 SPARE 0 20 17 18 .20 1800 HOUSE KEEPING RECEPTACLES RECEPTION 102 QUADS 1140 19 20 20 600 MED ROOM 122 SC 60A5/NF/WP 6OA51NFIWP 6OA5/NF/WP Tan-gel Engineering Associates, P.C. GENL MEC 102 104 1260 20 21 22 20 600 MED ROOM 122 SC NEMA 5R NEMA 5R NEMA 5R Consulting Engineers COPIER SC 102 100 20 23 24 20 1500 JANITORS 124 GFI SC QUADS 104,102 1080 20 25 26 20 0 SPARE 285 Middle Country Road,suite los QUADS 110 1080 20 27 28 20 0 SPARE RTU-I RTU-2 RTU-3 ROOF Smithtown,NY 11787 SPARE 0 20 29 30 20 BR Phone:631.750.2800 QUADS 117 1080 31 32 2t1 1500 BREAK ROOM 118 GFCI MED ROOM SEP CKT OUTLET 1500 20 33 34 20 1500 BREAK RM 110 SC Fax:631.750.2744 QUADS 117 1440 20 35 36 20 1500 OBGYN 125 SC tangelengineering.com QUADS 116,114 720 20 37 38 20 1500 OBGYN 126 SC 4#8+#106, 1"G SPARE 0 20 39 40 20 1500 IT ROOM SC SPARE 0 20 41 42 20 1500 IT ROOM SC 4#5+#106, 1"G 4#5+#106, I"G This drawing has been prepared for the indicated project and is an instrument of SUBTOTAL PHASEA 4320 TOTAL PHASE A 11340 7020 SUBTOTAL PHASE A service copyrighted by Mancini Architecture SUBTOTAL PHASEB 3840 TOTAL PHASE B 11580 7740 SUBTOTAL PHASE B 4#4/O+#4p, 2-I/2"C PLLC. This drawing may not be copied or SUBTOTAL PHASEC 2440 TOTAL PHASE C 11140 8700 SUBTOTAL PHASE C 4#4/0+#4 6, 2-I/2"G used, in whole or part, any party without the expressed written consent of Mancini TOTAL CONNECTED WATTS 34060 Architecture PLLC. Infringements or any use of this drawing for any other purposes will be prosecuted to the full extend of criminal law OM LP-1 LP-2 KEY PLAN " 200A5/NF GROUND FLOOR '�� O �, j" Co 0 ELECTRICAL R15ER DIAGRAM (NOT TO SCALE) �0,p �C586� � NOTES: '4JFSS0°��`, I. ELECTRIC METER DETAIL, MAIN DISCONNECT SWITCH, FEEDERS TO, PANELS ARE TO BE FURNISHED AND INSTALLED BY LANDLORD. PROJECT STONY BROOK MEDICAL 10095 MAIN ROAD MATTITUCK, NY 11952 DRAWING TITLE ELECTRICAL PANEL SCHEDULES AND DETAILS SCALE AS SHOWN DRAWN BY ABB DRAWN FOR TET CHECKED BY TET PROJECT# 20-021 DATE SHEET NO. E-401 SHEET 3 OF 4 NO. REVISIONS DATE '7. WIRING DEVICES 1 ISSUED FOR REVIEW 5/12/2020 I. GENERAL PROYIVON5 A. RECEPTACLES: ALL RECEPTACLES TO BE PROVIDED WITH U LECCND AND COORDINATION A. 6ENERAL NOTES: SHAPED 6ROUNDIN6 CONTACT. ALL RECEPTACLES SHALL BE AS 2 95% ISSUE 5/14/2020 I. THE CONTRACTOR COVENANTS AND A61REE5 THAT HE AND H15 E. PROTECTION: KEEP CONDUITS AND OTHER OPENIN65 CLOSED TO 5PECIFIED BELOW UNLESS OTHERWISE NOTED BY THE ARCHITECT. SYMBOL DESCRIPTION 3 COMPLETED 5/22/2020 PREVENT THE ENTRY OF FOREIGN MATTER; COYER FIXTURES, B. ALL DEVICES SHALL BE 6ANGED IN A COMMON 6ANCED FIN15H SUBCONTRACTORS AND H15 AND THEIR AGENTS, SERVANTS AND EQUIPMENT AND APPARATUS AND PROTECT A6AIN5T DIRT, WATER, PLATE AS REQUIRED TO ACCOMMODATE ALL SWITCHES AND/OR CONSTRUCTION SET EMPLOYEES WILL PROVIDE AND MAINTAIN A SAFE PLACE TO WORK CHEMICAL OR MECHANICAL DAMAGE, BEFORE AND DURING THE RECEPTACLES. AND THAT HE AND THEY WILL COMPLY WITH ALL LAWS AND CONSTRUCTION PERIOD UNTIL FINAL ACCEPTANCE, INGLUDIN6 G.ALL OUTLETS IN PATIENT CARE SPACES, INGLUDIN6 BUT NOT �--� CIRCUIT HOME RUN TO PANEL 4 COMPLETED 6/04/2020 REGULATIONS OF ANY GOVERNMENTAL AUTHORITY HAYING RESTORATION OF DAMAGED SHOP GOATS OF PAINT. EQUIPMENT NECESSARILY LIMITED TO EXAMINATION ROOMS AND TREATMENT JURISDICTION THEREOF AND THE CONTRACTOR AGREES TO SHALL BE DELIVERED AND STORED ON SITE, PROPERLY PACKAGED ROOMS SHALL HAVE HOSPITAL 6RADE OUTLETS. GROUND FAULT CIRCUIT CONSTRUCTION SET INDEMNIFY, DEFEND AND HOLD HARMLESS THE CONSULTING AND GRATED UNTIL FINAL INSTALLATION. 6FGI INTERRUPTER DEVICE 5 COMPLETED 6/12/2020 ENGINEER, THE ARCHITECT AND THE OWNER FROM AND AC7AIN5T F. COORDINATION WITH OTHER TRADE5: RENDER FULL COOPERATION ANY LIABILITY, LOSS, DAMAGE OR EXPEN5E, INGLUDIN6 ATTORNEY'S TO OTHER TRADES. WHERE WORK OF CONTRACTORS WILL BE 8. L16HTINC FIXTURES: G CONDUIT CONSTRUCTION SET FEES ARISING FROM FAILURE OR ALLEGED FAILURE ON THE PART INSTALLED IN CLOSE PROXIMITY TO WORK OF OTHER TRADES, THIS 6 ISSUED FOR PERMIT 7/07/2020 OF THE CONTRACTOR, HIS SUBCONTRACTORS AND HIS AND THEIR CONTRACTOR SHALL ASSIST IN WORKING OUT SPACE CONDITIONS. A. ALL L16HTIN6 FIXTURES SHALL BE A5 SPECIFIED BY THE 6 GROUND A&ENT5, 5ERVANT5 AND EMPLOYEES TO PROVIDE AND MAINTAIN A IF CONTRACTOR INSTALLS WORK BEFORE COORDINATING WITH ARCHITECT. SAFE PLACE TO WORE: OR TO COMPLY WITH ALL LAWS AND OTHER TRADES, OR CAUSES INTERFERENCES, HE SHALL MAKE B. ALL LIGHT FIXTURES AND FIXTURE WIRING SHALL BE IN RE6ULATION5 OF ANY' 60VERNMENTAL AUTHORITY HAVING CHAN6E S NECESSARY TO CORRECT CONDITION WITHOUT ANY EXTRA ACCORDANCE WITH THE NY5 ENERGY CONSTRUCTION CONSERVATION DISCONNECT SWITCH JURISDICTION THEREOF. CHARGE. CONTRACTOR SHALL COORDINATE WITH THE SPRINKLER CODE. CONTRACTOR FOR THE LOCATION AND TYPE OF TAMPER SWITCHES, 2. THE CONTRACTOR AND EACH 51JBCONTRACTOR COVENANTS AND WATER FLOW SWITCHES, REQUIRED CONTACTS, VOLTA6E5, AND 0 JUNCTION BOX 120V/206V ASREE5 TO INDEMNIFY, DEFEND AND HOLD HARMLESS THE WIRING DIA6RAM5. CONTRACTOR FOR THE LOCATION AND TYPE OF Q. CROUNDIN6 CONSULTING ENGINEER THE ARCHITECT AND THE OWNER FROM AND COMBINATION FIRE 5MOKE DAMPERS, DUCT SMOKE DETECTORS, [f� A6AIN5T ANY LIABILITY, LOSS, DAMAGE OR EXPENSE, INGLUDIN6 REQUIRED CONTACTS, VOLTAGES, AND WIRING DIAGRAMS. A. THE ELECTRICAL SYSTEM AND EQUIPMENT SHALL BE GROUNDED. 'It X - NEW ATTORNEY'S FEES ARISING FROM A FAILURE OR ALLEGED FAILURE C. GUARANTEE AND SERVICE: UPON ACCEPTANCE OF THE 6ROUNDIN6 CONDUCTOR SHALL BE AN INSULATED COPPER WIRE ON THE PART OF THE CONTRACTOR, HIS SU5CONTRACTOR5 AND HIS CONTRACT,GONTRACTOR A&REE5 TO GUARANTEE ALL HI5 WORK OF THE REOUIRED SIZE. AGGE551BLE CONNECTIONS SHALL BE MADE SPECIAL OUTLET AS PER AND THEIR A&ENT5, SERVENT5 AND EMPLOYEES PROPERLY TO AND EQUIPMENT FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR WITH MULTIPLE BOLT SILICON BRONZE CONNECTORS SPECIFICALLY PLANS DISCHARGE THE OBLIGATIONS ASSUMED BY HIM OR THEM IN THE FROM DATE OF INITIAL START UP. MANUFACTURER'S GUARANTEE DE516NED AND APPROVED FOR THE CONNECTION TO BE MADE. 2OA/2P FOR PTAC AC UNIT PERFORMANCE OF THE WORK, INGLUDIN6 ANY ACT OR OM195ION AND SHALL NOT BE LE55 THAN ONE (1) YEAR. CONNECTIONS SHALL BE AS MANUFACTURED BY BURNDY OR O.Z. ALLEGEDLY RESULTIAS IN DEATH OR PERSONAL INJURY OR H. INSURANCE: CONTRACTOR SHALL MAINTAIN SUCH LIMITS OF ELECTRIC,. 6ROUNDIN6 CONDUCTORS SHALL BE PROVIDED ACROSS HC7 HOSPITAL GRADE PROPERTY DAMAGE OR IMPROPER CONSTRCONSTRUCTIONUCTION, ONSTRUCTION INSURANCE AS DIRECTED UNDER THE 6ENERAL CONDITIONS. METAL PARTS WHIGH ARE SEPARATED BY NON CONDUCTIN6 TEGHNIQUE5 OR THE USE OF IMPROPER OR INAPPROPRIATE I. TEMPORARY LIGHT AND POWER: PROVIDE AND MAINTAIN ALL MATERIALS OR JOINED 50 THERE 15 HIGH RE515TANCE AT THE MATERIAL OR TOOLS. FACILITIES FOR TEMPORARY LIGHT AND POWER WITHIN THE JOINTS. 2'x4' RECESSED LAY-IN LED 3. THE CONTRACTOR AGREES THAT ANY CONTROVERSY OR P15PUTE CONSTRUCTION AREA DURING THE ENTIRE BUILDING PERIOD, FOR LIGHT FIXTURE SAFETY OF PERSONNEL, UTILIZING THE EXISTING ELECTRIC SERVICE 10. SAFETY SWITCHES TO WHICH THE C.ONTRI�GTOR, THE ARCHITECT, AND THE CONSULTING WITHIN THE AREA A5 ARRANGE WITH THE 5UILDIN6 OWNER BY THE ENGINEERS ARE PARTIES SHALL BE SUBMITTED TO ARBITRATION ELECTRICAL CONTRACTOR. A. SAFETY SWITCHES SHALL BE HORSEPOWER RATED HEAVY DUTY FZ2'x2' RECE55XT LAY-IN FOR DECISION IN ACCORDANCE WITH THE RULES OF SUCH J. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE SUBMITTED FOR TYPE WITH QUICK-MAKE/ QUICK-BREAK MECHAN15M AND COVER LED LIGHT FIXTURE ASSOCIATION FOR CONSTRUCTION INDUSTRY DISPUTES. ALL APPROVAL PRIOR TO ORDERING AND INSTALLATION E THE SAME INTERLOCK. HANDLE SHALL BE CAPABLE OF BEING PADLOCKED IN MANCI 1\4 SUBCONTRACTORS LIKEWISE AGREE TO SUBMIT TO SUCH FOUR COPIES OF EACH SUBMITTAL ARE REQUIRED. THE OFF POSITION. SWITCH SHALL BE FUSED OR UN-FU5ED A5 ARCHITECTURE ARBITRATION ANY DISPUTE BETWEEN OR AMONG THEM, THE K. LOCATIONS: DRAWIN65 ARE DIA&RAMMATIG AND INDICATE INDICATED. DISCONNECT SWITCHES FOR FANS SHALL HAVE BUILT IN EMERGENCY LIGHT FIXTURE WITHM U I CONTRACTOR, THE ARCHITECT AND THE CONSULTING ENOINEER5, GENERAL ARRAN6EMENT OF SYSTEMS. CIRCUIT NUMBERS ARE FOR THERMAL OVERLOADS. BATTERY PACK CONSTRUCTION AND THE CONTRACTOR A6REE5 TO MAKE AVAILABLE TO THE IDENTIFICATION ONLY USE AVAILABLE SPARE CIRCUIT BREAKERS B. OUTDOOR SWITCHES SHALL BE NEMA 3R. C.ONSULTIN6 ENOINEER5 ON DEMAND 516NED COPIES OF THE ELECTRICAL CONTRACTOR TO VERIFY IN THE FIELD. FOR EXACT 222 Middle Count Rd. Suite 314 CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR AND LOCATION of RECEPTACLE, LIGHTING FIXTURES, TELEPHONE AND II. PANELBOARDS AND CABINETS WALL MOUNTED OCCUPANCY SWITCH Country BETWEEN THE CONTRACTOR AND HIS SUBCONTRACTORS. THE 516NAL OUTLETS REFER TO ARCHITECTURAL DRAWIN65. WHERE Smithtown, NY 11787 CONTRACTOR AND EACH SUBCONTRACTOR A6REE THAT BY A. PANELBOARD CABINETS SHALL BE OF THE GENERAL PURPOSE, T: 631-979-0104 NEW WORK INTERRUPTS THE ELECTRICAL TELEPHONE DEAD FRONT TYPE FOR FLUSH OR SURFACE WALL MOUNTED AS O GEILIN6 MOUNTED OCCUPANCY SUBMITTING A BID WHICH 15 ACCEPTED, TH15 PARAGRAPH SHALL BE F: 631-979-3445 DEEMED A WRITTEN AGREEMENT TO SUBMIT ANY CONTROVERSY SYSTEM WHICH 15 TO REMAIN,, EEX1XISTTING SYSTEMS SHALL BE MODIFIED AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE. INDICATED ON THE DRAWINGS. MOUNT THE TOP OF THE CABINET OGG SENSING SWITCH info@manciniarchitecture.com THEREAFTER AR151N6 ARBITRATION. L. RUBBISH: REMOVE RUBBISH FROM PREMISES A5 OFTEN AS 6-6" ABOVE FINISHED FLOOR. CABINET SHALL BE FABRICATED VERNING DIRECTED. ALL WORK AND EQUIPMENT SHALL BE GLEANED TO THE FROM HOT GALVANIZED SHEET METAL GAU6E5 SHALL MATERIAL BE DIM HALL MOUNTED DIMMER SWITCH 4. ALL WORK SHALL BE DONE IN CONFORMANCE WITH ALL GOWN CODES, INGLUDIN6 AMENDMENTS, BULLETINS, ETC., AS WELL VE SATISFACTION OF THE OWNER AND TENANT BEFORE TURNING SAME LIGHTER THAN 14 6AU&E. OUTSIDE OR SURFACE MOUNTED OVER TO THE OWNER AND TENANT. CABINETS, TRIM AND PANELBOARD FRONTS SHALL BE GIVEN A STANDARDS OF INSTALLATION AND EQUIPMENT ESTABLISHED FOR M. AS BUILT DRAWING: SUBMIT DRAWING INDICATING AS BUILT GOAT OF ZING CHROMATE PRIMER AND ONE FINISH GOAT OF ® ® EXIT LIGHT THE BUILDIN6, AND REQUIREMENTS OF THE OWNER. CONDITION INGLUDIN6 COMPLETED PANEL 50HEMLM WHEN ENAMEL. TRIM OF PANELBOARD FRONT SHALL BE MADE OF GOLD INSTALLATION 15 COMPLETE. ONE (1) PRINT AND ONE AUTOGAD FILE ROLLED 5HEETMETAL OF 0AU6E5 AS REQUIRED BY UL, EXCEPT TELEDATA OUTLET 4"x4" 6ALYANIZED S. SCOPE: PROVIDE LABOR, MATERIALS, EQUIPMENT AND SERVICES ON GD SHALL BE SUBMITTED TO TAN6EL ENGINEERING THAT THEY SHALL NOT BE LESS THAN12 GAU6E. TRIM SHALL HAVE FOR COMPLETE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS DOORS WITH CONGEALED HIN6E5 AND SHALL HAVE FLUSH MOUNTED WORKBOX WITH 3/4 EMPTY CONDUIT TO1 -* A ASSOCIATES,RPC. FOR OUR RECORDS A5 WELL A5 ANY AND ALL TYPE COMBINATION LOOK AND CATCH OR A MULTIPLE POINT AND AS REQUIRED BY' APPLICABLE CITY, STATE AND FEDERAL ABOVE HUNG GEILIN6. PROVIDE (2) 7; DRAWINGS REQUESTED BY THE BUILDING OWNER AND TENANT. CONTACT CATCH. EACH LOOK SHALL BE PROVIDED WITH TWO GORES, INGLUDIN6 OSHA. PAY ALL FEES AND OBTAIN ALL NYLON DATA LINES. DATA GABLE, CERTIFICATES AND PERMITS REQUIRED TO BEGIN AND COMPLETE MILLED TYPE KEYS. ALL PANEL.BOARD5 SHALL BE KEYED ALIKE. TERMINALS AND FINISH PLATES BY 2. 5COPE OF WORK TYPEWRITTEN DIRECTORIES UNDER 6LA551NE SHALL BE PROVIDED Tan_gel Engineering Associates, P.C. CONSTRUCTION. USE ��L..L NEW UL AND NYC, BSA APPROVED TELEDATA CONTRACTOR EQUIPMENT. ALL EQUIPMENT SHALL BE BUILDING STANDARD OR ON DOORS. DIRECTORIES SHALL CLEARLY INDICATE CIRCUIT SUBJECT TO BUILDING APPROVAL PRIOR TO INSTALLATION. IT A. PROVIDE ALL NEGE55ARY TEMPORARY POWER AND LIGI•tTIN6 Consulting Engineers NUMBERS AND DESCRIPTION OF THE ASSOCIATED BRANCH CIRCUIT. REQUIRED FOR ALL TRADES INCLUSIVE OF TEMPORARY POWER ® GUAD OUTLET SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT DIRECTORIES FOR SWITCH AND FUSED PANELS SHALL AL50 PANELS ON EACH FLOOR AND GENERAL SITE AREAS. THIS WORK 15 ANY AND ALL EQUIPMENT BEING INSTALLED 15 ACCEPTABLE TO THE INDICATE SWITCH FUSE AND BRANCH FEEDER SIZE. ALL DETAIL BUILDING MANAGEMENT. INCLUDE ALL TEMPORARY LIGHTING 285 Middle Country Road,suite 208 AND NOT INDICATED ON BID DOCUMENTS AND MUST BE COORDINATED CHARACTERISTICS SUCH A5 NUMBER OF BRANCHES, FRAME OR MOTOR POWER DURING CONSTRUCTION. INCLUDE ALL TEMPORARY LIGHTING WITH THE CONSTRUCTION MANA6EMENT FOR REQUIREMENTS. AMPERE RATING, TRIP OR FUSE SIZE, ETC.... SHALL BE A5 INDICATED Smithtown,NY 11787 B. FURNISH, AND INSTALL LIGHTING. LOWER CASE LETTER DESIGNATES Phone:631.750.2800 AND POWER DURING CONSTRUCTION. INTERRUPTION OF POWER IF ON DRAWINGS. EACH CABINET SHALL HAVE A GROUND LU WELDED REQUIRED SHALL BE COORDINATED WITH THE BUILDING G. FURNIS4 AND INSTALL ALL POWER DISTRIBUTION OENNECT TO THE INSIDE OF EACH CABINET BOX. CUTTER SIZES SHALL BE a SWITCH t Fax: gelen ineern44com MANAGEMENT. D. FURNISH AND INSTALL BRANCH CIRCUITS AND DISCONNECT ACCORDANCE WITH NYC CODE PARA6RAPH 830-4-lV. MINIMUM s s s SWITGH�S TO SERVICE EQUIPMENT. WH WATER HEATER E. FURNISH AND INSTALL EMERSENGY 1-16HTS AND EXIT LIGHTING. 6UTTER SIZE FOR ALL POWER DISTR SUTION PANELS SHALL BE 6". 6. OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM F. FURNISH AND INSTALL NEW PANELS. FINISH GOAT OF ENAMEL SHALL BE CRAY FOR 120/205 VOLT TX TOILET EXHAUST FAN This drawing has been prepared for the C0VERNIN6 AUTHORITIES. Cr. FURNISH AND INSTALL CIRCUIT BREAKERS IN ELECTRIC, PANELS A5 PANELS. CIRCUIT BREAKERS SHALL BE OF THE BOLT ON TYPE. A indicated project and is an instrument of SHOWN ON PANEL SCHEDULES. THREADED BOLT SHALL BE INSTALLED IN THE TOP LIP OF THE EF EXHAUST FAN service copyrighted by Mancini Architecture '1. ALL EQUIPMENT AND MATERIALS SHALL BE NEW, UL LISTED AND H. ALL EXPOSED BRANCH CIRCUITS SHALL BE IN CONDUIT. PANEL BOARD BOX AND A HOLE SHALL BE DRILLED IN THE FACE PLLC. This drawing may not be copied or SHALL CONFORM TO ANY ADDITIONAL LABELING, TE5TIN6 AND I. ALL BRANCH WIRING ON LOWER LEVEL SHALL BE IN CONDUIT. OF THE PANEL TO ALLOW FOR EASY MOUNTING AND REMOVAL OF HWRP HOT WATER RETURN PUMP used, in whole or in part, by any party without CONSTRUCTION REQUIREMENTS ESTABLISHED BY THE 60VERNIN6 J. ALL AG WIRING MUST BE SUPPORTED AND SECURED WITH GABLE THE PANEL COVER. the expressed written consent of Mancini AUTHORITIES. THE SAME SHALL BE GUARANTEED FOR I YEAR CLAMPS TO TRAPEZE SUPPORTS SUPPORTED TO BUILDING Architecture PLLC. Infringements or any use SUBSEQUENT TO FINAL. ACCEPTANCE. STRUCTURE. 12. MEDICAL EQUIPMENT SEPARATE CIRCUIT OUTLET of this drawing for any other purposes will be K. FURNISH AND INSTALL CONTROL WIRING THE ELECTRICAL CONTRACTOR SHALL OBTAIN THE COMPLETE prosecuted to the full extend of criminal law 5. COORDINATE SCHEDULING OF ALL WORK TO BE PERFORMED WITH L. FILE FOR AND OBTAIN ALL PERMITS, INSPECTIONS, AND FINAL INSTALLATION INSTRUCTIONS FOR THE SPECIALIZED MEDICAL OWNER AND INCLUDE ALL NECESSARY PREMIUM TIME REQUIRED FOR SIGNOFFS FOR ALL ELECTRICAL AND FIRE ALARM SYSTEMS. EQUIPMENT AND SHALL PROVIDE ALL POWER CIRCUITS, GROUNDING, NICHT LIGHT (UN-SWITGHE D ON 24/7) SHUTDOWNS, WORK IN OCCUPIED AREAS, ETC. M. PROVIDE SUPERV15ION AND LABOR AS REQUIRES FOR DISCONNECT SWITCHES, OVERGURRENT PROTECTION, CONTROL CONSTRUCTION PROJECT. WIRIN6, ETC, AS SPECIFIED BY THE MANUFACTURER. COORDINATE EY PLAN a. NO ELECTRICAL CONNECTIONS SHALL BE MADE TO, OR WORK THE LOCATION OF ALL DEVICES WITH THE ARCHITECT. � PERFORMED ON, ENEF6IZE:D EQUIPMENT. N. PROVIDE AND SUBMIT SHOP DRAWING FOR ALL EQUIPMENT, TG TIME /'.LOCK �O� MATERIALS AND METHODS FOR ALL WORK ON THE PROJECT. THE 10. ALL AREAS ASSOCIATED WITH WORK TO BE PERFORMED SHALL BE CONSTRUCTION SHALL OFFER ALL NECESSARY COORDINATION AND EXAMINED. NO ADDITIONAL COMPENSATION SHALL BE MADE FOR ASSISTANCE TO ALL TRADES AS REQUIRED TO SUBMIT A COORDINATED (ALL TRADES) SHOP DRAWING AND AS BUILT tel`; CONDITIONS FOUND DURING INSTALLATION. DRAWINGS. II. SURVEY EXISTING SPACE CLOSETS AND PANELBOARDS TO VERIFY = �` WIRE AND CABLE s55 C'� SUITABILITY OF INSTALLATION DESIGN INDICATED. ANY 3. MODIFICATIONS NECESSARY TO COMPLY WITH THE DESIGN .o INDICATED. ANY MODIFICATIONS NECESSARY TO COMPLY WITH THE A. WIRE SHALL BE COPPER. INSULATION TYPE "THHN". 85,0;:; DE516N INTENT SHALL BE INCLUDED IN 510 SUBMITTED AND SHALL B. CONDUCTOR SIZE SHALL BE AS INDICATED ON DRAWIN65, NOT LESS BE HIGHLI6HTE:D 50 THAT CONSIDERATION TO THE SAME 15 61VEN THAN #12 AW6 (THHN) FOR POWER AND LI6HTIN6 WORK; NOT LESS DURING BID EVALUATION. OF THE AVAILABILITY OF BRANCH CIRCUIT THAN #14 FOR CONTROL WIRIN6 CIRCUITS. CONDUCTORS IN EXCESS CAPACITY TO ACCOMMODATE THE NUMBER OF BRANCH CIRCUITS TO OF 100 FEET SHALL BE #10. ALTERNATE PANELS OR THE ADDITION OF SUPPLEMENTAL PANELS, G. FACTORY COLOR CODING USING THE SAME CODE THROU614OUT INGLUDIN6 FEEDERS, SHALL BE INCLUDED IN BID PROPOSAL C'IRC'UIT SHALL BE A5 FOLLOWS: 120/240 VOLTS - BLACK, RED, BLUE AND NUMBERS INDICATING ARE REFERENCE ONLY. WHITE; WHITE CONDUCTOR SHALL SERVE AS NEUTRAL CONDUCTOR. 6REEN CONDUCTOR SHALL BE USED WHERE 6ROUND WIRE 15 12. ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL SPECIFIED. ROJECT REQUIREMENTS OF ALL NEW EQUIPMENT TO BE USED. ALL D. ELECTRICAL CONTRACTOR SHALL FURNI5H AND INSTALL STONY BROOK DEDICATED 208/I/20AMP OUTLETS FOR PTACS INDICATED ON WALLBOXE:S AND CONDUIT FOR ALL TELEDATA AND SIMILAR LOW FLOOR PLANS SHALL BE ORANGE. VOLTAGE GABLE. LOW VOLTAGE GABLE SHALL BE UNDER MEDICAL SEPARATE CONTRACT. 13. PROVIDE PLYWOOD 13ACKBOARD ON OL05ET WALLS FROM FLOOR E. ALL GABLE ABOVE THE HUNG GEILIN6 SHALL BE PLENUM RATED 10095 MAIN ROAD TO 5 FEET ABOVE FINISHED FLOOR WHERE EQUIPMENT 15 TO BE CABLE. MATTITUCK, NY 11952 MOUNTED. BACKBOARD TO BE FIRE RETARDANT. F. ALL WIRIN6 SERVING PATIENT CARE AREAS INGLUDIN6 BUT NOT NECESSARILY LIMITED TO EXAMINATION ROOMS AND TREATMENT A. WORKMANSHIP: ALL EQUIPMENT AND MATERIALS SHALL BE ROOMS SHALL BE CIRCUITED WITH H05PITAL 6R.ADE WIRIN6 IN DRAWING TITLE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE SECTION 511. B. MATERIALS: ALL MATERIALS SHALL BE OF THE BEST QUALITY FOR THE PURPOSE INTENDED. TRADE NAMES AND CATALOG NUMBERS ELECTRICAL ARE INTENDED TO INDICATE THIS QUALITY. CONTRACTOR SHALL 4. TAPS, SPLICES AND TERMINATIONS SPECIFICATIONS SUBMIT SHOP DRAWIN55 AND/OR MANUFACTURERS CERTIFIED GUTS TO THE ENGINEER AND THE ARCHITECT AND OBTAIN WRITTEN A. CONNECTORS FOR LIGHTING FIXTURES FROM BRANCH CIRCUIT APPROVAL FROM THE' ENOINE:ER AND THE ARCHITECT FOR ANY AND WIRIN6 SHALL BE MADE WITH TWIST ON TYPE CONNECTORS, T45 ALL SUBSTITUTIONS. SERIES PT-L, OR EQUAL OF 3M OR IDEAL. G. MOTORS: THE HORSEPOWERS INDICATED ON PLANS AND/OR IN GALE AS SHOWN SCHEDULES ARE THE I-10RSEPOWER REQUIREMENTS OF EQUIPMENT 5. CONDUITS AND FITTIN65 FURNISHED UNDER OTHER SECTIONS OF WORK. ALL FEEDERS DRAWN BY ABB (CONDUIT AND WIRIN6) AND DISGONNECTIN6 DEVICES SHALL BE OF A. CONDUITS: ALL POWER WIRIN6 IN RACEWAYS; MINIMUM SIZE THE SIZES AND CAPAITIES TO SUIT THE HORSEPOWERS OF MOTORS CONDUIT TO BE 3/4". USE EMT IN ALL EXP05ED AREAS, ALL DRAWN FOR TET C ACTUALLY FURNISHED UNDER THE VARIOUS SECTIONS. CELLAR SPACES. USE AG GABLE OR ALL BRANCH CIRCUITS. NECKED BY TET D. GUTTING AND PATCHING: ALL GUTTING AND PATCHIN6 IN B. ALL MAIN FEEDERS SHALL BE IN EMT CONDUIT. CONNECTION WITH THIS TRADE SHALL BE DONE AS PART OF TH15 G. GROUNDING BUSHIN65 SHALL BE OZ. TYPE 51-6, OR APPROVED PROJECT# 20-021 CONTRACT. TH15 CONTRACT SHALL BE RESPONSIBLE FOR THE EQUAL. ATE -------- REPAIR AND/OR REPLACEMENT (INGLUDIN6 ALL LABOR AND D. CONDUIT TERMINATIONS SHALL HAVE DOUBLE LOCKNUTS, T4B MATERIAL COSTS) FOR ANY OR ALL DAMAGE DONE BY HIMSELF OR SERIES 141 OR A5 APPROVED. SHEET NO. HIS WORKMAN, AND 544ALL COORDINATE HI5 WORK WITH THAT OF E. ALL CONDUIT OUTDOORS SHALL BE RIC71D THREADED ALUMINUM THE OTHER TRADES. ALL WORK SHALL BE DONE TO THE CONDUIT, SATISFACTION OF THE: ARCHITECT. E-501 6. OUTLET BOXES A. 6A..VANIZED STEEL AND OF STANDARD SIZES SUITABLE FOR THE USE INTENDED AND CONFORMING TO THE FOLLOWING: a) EXTERIOR OUTLET WITH HINGED AND GASKETED COVER PLATE. SHEET 4 OF 4 NO. REVISIONS DATE 1 ISSUED FOR REVIEW 5/12/2020 AND COORDINATION ....................................................... _................ ..................................................................................................................__"ii ( 2 95% ISSUE 5/14/2020 e............_.,: I i 3 COMPLETED 5/22/2020 . ..; O CONSTRUCTION SET I U11NOTE5* 0 0 I. LOCATION OF EXISTING ROOFTOP 6A5 FIRED AG UNITS IS AS SHOWN 4 COMPLETED 6/04/2020 r i ,........._T.. i! FMNI5H AND INSTALL NEW 6A5 FIRED AG UNIT. REFER TO MECHANICAL i SCHEDULES AND SPECIFICATIONS CONSTRUCTION SET ..._............. ........... ...... .......... i_......____.._._......._...__..._._..._........_. 2. RETO SANITARY, DOMESTIC WATER AND GAS RISER DIAGRAMS. CONSTRUCTION SET FER 5 COMPLETED 6/12/2020 i j I 4" 3. ALL SANITARY PIPING SHALL BE BELOW CONCRETE FLOOR SLAB. 6 ISSUED FOR PERMIT 7/07/2020 CONNECT GW 4 HKim4. ALL FLOOR DRAINS SHALL HAVE SELF PRIMING TRAPS AND AUTOMATIC _ ' PIPING TO EXI5TIN6 TRAP PRIMERS I........ 5. FOR THE PURPOSES OF THE5E DOC4MENT5, WE A55UME THAT THE i .b..:.; INCOMIN6 WATER SERVICE 15 PROTECTED BY AN EXISTING RPZ. :..:::..::::::::::::::::: ....._ LANDLORD SHALL VERIFY THAT THERE 15 AN EXISTING, COMPLIANT RPZ f BACKFLOW PREVENTER AT THE WATER SOURCE ENTERING THE BUILDING. ............................. .............. ............................ ..................................I i I i o : : i , i I i ,�:. .. :.__.._._ .... .-- _... ::::3ti:'::N i i ............------- ......... ............................................................................................................. ................................. --- it ............................ �............................. ___ ___ __. _ .__ _._ ___ _ ___ _ ___ ._._ ......... __ __ __ _ _ ... .. 'I I i E=XISTING ENTRANCE PLUMBING PLAN MANCIN 2 1 /4 11=1 I-01P ARCHITECTURE M U I CONSTRUCTION ! i 222 Middle Country Rd. Suite 314 Smithtown, NY 11787 I T: 631-979-0104 i F: 631-979-3445 i info@manciniarchitecture.com _...__..-.__. .__._..- -......................................_._.......---._._.._._..------_...__._.__.___ ____._.__._. _.._......._._..._.._....._.._........_.._.._._................_................._......._.._..................__.____.._..........................._....._........_......- ............—......__..........._.....__._.._..._._...--,-,--�..---_-_.. —,-,-- --._..__._.......------,-----__.._.___-- .................................................................................................................................................._........._..--........._..................---............._.__..........---------. _.__... - --...__.._._..- -- - .. _.._.__............................._........................v............................_......._. _._._.__.._..-... _......................_....-.--.. _ f i i NEW 2"CW CONNECTION ( f f IN WATER METER ROOM I ✓ I i• _ ........... ... ......... ....._.___..._.. . _.._.._.......... _---- .._._............_........................_.._..............._ I f r I .......... :::. ....................._....... ... .................._............. r iE ......... . .........._... . i i <i_.'.I, /1,' ✓/!. ;: - ii ;._.._... .. .. ....... ............._.I... . . _....... I ��r EXAM RTU-3 ON . _....................... _ - I O FICE� �)GR ................................._...... EXAM EXAM WAITING ........................._ ...�..a 1062 al11111......................._._... .. ..... (SENOTE U ........... IOU C2 1113 7/.— ............_............ .......................... ..... f........... . ...... I Ii SK SK� ;I Tangel Engineering e eri Associates, P Consulting Engineers CONSULT - - — - - -- 285 Middle Count Road Suite 208 Al / I n ✓ f Country _ r ..: ff/. ::lll/I� 11f1.� ✓ ;""i .+ .. ................................,... ._...__..,......._.. r �; �% Smithtown,NY 11787 �............_. %// 1//1/1/ilf. �� l _111 .1l i _ 1//11/1_.1. 11�111I1� .11111" _111111 E `----------------._.._. „ I I/2 ,, -._......_..._._._._.... �' Phone:631.750.2800 f r Fax'631 50 27 / ? 2 T 2 i tangelengineering.com ' I.T, -" .. — / I1, ,1 p 1,10 I-I/2" I 4 I-I/2" I G I This drawing- 2„ 2„ --.; wing h as been prepared for the ......................_ _ :.._____.__...__..__ I I I ly I I =-- _ __-- indicated project and is an instrument of ,. .............. ._..,..: ... .....,...............,,,. . .. .., ...._.._........... ................. ;,- . . I l I l service copyrighted by Mancini Architecture r.I I l ..........._..................__............ .. ........ .......... I%._.�......: l/,// 1 ...1111...11II111r1rf/1/ ..... f ---....... ................... .... /.. >: > PLLC. This drawing may not be copied or 11 ;...1/,:../l. ///.///111 i 11/l_/i. _. / 111. / /I//l////.1/./...//_l r.,: 1....11 .... FTf I / r J i / I , . 2„ . .. � f i, � ,` i � ; V ✓ I i used in whole or in part by any party without f f % f ✓.... ... i the expressed written consent of Mancini / r I I ' "! f _....._..___..............................._.____..._ ........... Architecture PLLC. infringements or an use ,...,................._........ ... I PHYSICIANS f ( _..............__............................._ f ., g Y j : I /111,.1111//.; r' ......._................................... _.................._ ! i his drawing for an other r ,� I purposes will be SfG ' OFFICE I PIA I ATION I I :. ._...=' of to ghe full extend of criminal,/1 „ ' - �.i P c nal law . ,E i s 11 f RECEPTION NEW 4 ..__........ ....-1_�_�....i ✓ } M ✓ ( j / ..... ✓ N _102 , III CONNECTION I 'IHS COM ✓ EXAM EXAM A ,ST T! , LAV y /; 103 p A 04 TO EXI5TIN6 HOUSE / �.........................� : i i f/ EXAM OBGYN r KEY PLAN DRAIN 4" JAN f : f.-...1,... I 12 .. I i I O= t tF r� / _f ; Y V' ; i _ - r 4 SINK — —- - — - — - -...----- -- - -- — -- -- -- -- -- _— n ; t � a i'- � � t E. }, (, ,,. 4,,, I i� IJANIT : i f f . 12 Lu .. .................._.....--...._... ....... __._.. �5K o - - - i HI / : I I I , ! ii : 1 1 f /1�.1 ._: 1,11/1111 .11,...11/.1 !`/1_,111111111/1f111/�111 / /_ _../ 1 /�11/1/1 _11_...11/_ ..1 ./._11/.1/ 1, lh/ll 11111/1//11///11111//1/11_�/� 1111<..11...11111_...1. .. �. /� r' 11.__111/1L711111.. ��11111/ 211 I' I I 21, RTU-2 ON ROOF �... .. I I ::................:::± I-I/2° I 4" I I I I f(SEE NOTE I) n, /—— ——— I ——— I 2n 4" 2" I " 1-I/2" 2° I-I/2° 2" „ 4,, 2" REAK ROOT 2 - - - - °A I - 2"�� II - - - - v I „ ' L � 11///1//. //F /... / 1/_..1//1 111.77777,..1 _,.. 11/11..: / . .... 3/4 1111/11 1 _1 11/11/,.1111..� .�...1.11,�... ,...A.... ,i�1 ... 1.._11 l ...11.....,._�. _....1.1111/1/..1�1/�............ .111/1 . (: f'1/1/15� > lTl1":�: `I1'� — — /� ', 1 " I I i I I PROJECT 5---" — — 1 2 5K I I/2 -� --- - - - _ 11 TONY BROOK 11 - 5K , i ��4 I S .. .. ,, CARE LAR : ; :� � i f LA _ RTU-I ON ROOF / MEDICAL 3/4 :-; � , 121 ...... ..... __ .. �j� ._ f , , (5EE NOTE I) j. — — — — WAITING 10095 MAIN ROAD , 1 RICK SJR — — — — 120 ._..... MATTITUCK, NY 11952 f I_... ✓ ( 127 .2_.. EXAM ,L; FD � �---------- / ! 8 1129 X130 119 f EX GYN BATHROOM AM f DRAWING TITLE ! i . . - EJ 123 '' 1 s ,I __._ 2 PL i r f ✓ UMBING PLAN ._............... ✓ SK 5K f f r f i f 4� ; I .:: .. ... ..:....:.......... : :: _..... _ ._. ,"............................._ .,,- ....._...... .........-..:.................._..................._.................................,. _ ....................:..:: ::�_:::.:�,>_-::._- rs'::.:a::=--:er-:.�:�::::;:;--::-��:::::.:::-�:.[::�_�__-_a_:.:!a:__:;a_.t::::r_�:_�': i: :. ............................................. I..__..._........... : ,...-:... :. .. .. _ .. .... ..... ............... ....... ............... ...................__................................................................................... ............................................................ ....... ......... .. _...._............................................_. _.. _. .. .. ............................................................................................ ....................._................_..__..__....................._._.._-_...._.-....-.---..........._........................__._.._.-_......-........_.._.._......_..._....__......._......._..................................................._......_ _.._....................._................ ....._..... :.-. ._....----..._.___.._..—'------"----'-- --.._.._._....—.._._-_.- -' '---- -- .._—....._. ----------'-------._._._........._..__..._........_..._._�_�_ .. ........... ....... .................................................... .................................. ..............._.. _....................__._ ..._._.._.....__._._._. ......._...._._--._...-__...._............_........................................_.........._..__.........__..._....._.......__.._....................-__--_,._- SCALE AS SHOWN .. ..... ..... ........ ... .._I.... ...... ..... ....... ...... ......_ ......-.. ........ _ .... ...... ......... ....... ....... ..... ..... ..... .... ..... .......... .......... .... . ........ ........ .......... .... ....... ........ ......... ......... ........ ......... .......... ......... _........ .......... ......... .......... ......... ......... ......... ..... ;..,... ......... ....... ... . .... ;. .. .. _ .......... ._...... _.... ....___ ..._..... .......... .......... ......... .......... ......... ......_. ......... ......... ......... ......... ......... ........ .. . .......... ......... ....... _- _..._. ... _.. ._...... ..._ _...... ........ ......... ._... ......... .......... _....... .......... .._..._. _..--- ......... _...... -- --- ---- --.... .__ .......... _._..... .......... .......... .._.... ......_ ...._..- --._... ......... _.___ _- -- --._... ._._._ _.... . _... ......... ...__ .......... .......... ---.... _..._ DRAW �" N BY ARC I DRAWN FOR W.._.....- ( TET ; CHECKED BY TET I PROJECT# 20-021 I DATE --/-_/__-- SHEET NO. P-101 GROUND FLOOR PLUMBING PLAN SHEET 1 OF 4 NO. REVISIONS DATE 1 ISSUED FOR REVIEW 5/12/2020 AND COORDINATION 2 95% ISSUE 5/14/2020 AUTOMATIC TRAP PRIMER 3 COMPLETED 5/22/2020 CONSTRUCTION SET 2 G 4 COMPLETED 6/04/2020 1/2" GW PRIMER FROM TO FIXTURE SOURCE CONSTRUCTION SET --- FLOW rul 5 COMPLETED 6/12/2020 CONSTRUCTION SET WATER DISTRIBUTION 14 GAUGE ZING 6 ISSUED FOR PERMIT 7/07/2020 UNIT C I COATED SHEET STEEL SADDLE, AT LEAST 1/2" GW PRIMER TO 6" LONG FLOOR DRAIN TRAP &A5 FIRED ROOFTOP UNION AIR GONDITIONIN6 UNIT 1/'2" GW PRIMER TO FLOOR FLOOR DRAIN TRAP DRAIN WATER PIPE TO DRAINAGE SYSTEM ;; ;; GAS C OCK ol FLOT '- OR DRAIN ' TRAP WITH PRIMING PI ROOF CURB CONNECTION 6A5 PIPE FLOOR I RA I N N 1 TH SELF PR I M I NO TRAP THERMO — WITH FULLL INSNS SHIELDULATION DIRT LE6 6" AND SMILIAR TO M-CO MA'R NCINI SMALLER ARCHITECTURE M U I CONSTRUCTION INSTALLATION DETAIL AT HANGER 222 Middle Country Rd. Suite 314 665 FIRE ROOFTOP AIR CONDITIONING UNIT OAS PIPING DETAIL Smithtown, NY 11787 BUILDING STRUCTURE MOT TO SCALE) T: 631-979-0104 F: 631-979-3445 STEEL PIPE REFER TO SPECIFICATION info@manciniarchitecture.com SLEEVE FOR PACKING OF SPACE BY HVAC BETWEEN PIPE & SLEEVE PIPE ® r r r r r Tan_gel Engineering Associates, P.C. rrrrrre r r Consulting Engineers SEE NOTE 285 Middle Country Road,Suite 208 NOTE: Smithtown,NY 11787 Phone:631.750.2800 PIPE SLEEVES SHALL BE LARGE Fax:631.750.2744 ENOUGH TO ALLOW FOR EXPANSION �— — — — CHECK VALVE tangelengineering.com ESCUTCHEON AROUND & CONTRACTION ALL PIPE, PENETRATIONS, This drawing has been prepared for the GOLD WATER indicated SEE SPECIFICATIONS FLOOD PREVENTION project and is an instrument of TO FIXTURES EXPANSION TANK VALVE service copyrighted by Mancini Architecture PLLC. This drawing may not be copied or PIPE SLEEVE THROUGH I GOLD WATER used, in whole or in part, by any party without the expressed written consent of Mancini SHUTOFF VALVE Architecture PLLC. Infringements or any use WALL DETAILTEMPERED (120°) WATER TO UNIT of this drawingfor an other purposes will be y p p TO FIXTURES — prosecuted to the full extend of criminal law �— — — — — GOLD WATER SUPPLY KEY PLAN HOT WATER THERMOSTATIC, RETURN PUMP MIXING VALVEo\, [ . HOT WATER RETURN A UNION (TYP) i d~ CHECK VALVE w 1%.M AI PRESSURE TEMPERATURE SAFETY VALVE GAS FIRED STORAGE TANK Q F"oon I WATER HEATER !!11]] PROJECT 6AS COCK BLOWOFF STONY BROOK 7 MEDICAL 10095 MAIN ROAD MATTITUCK, NY 11952 a ( I Q •° N ll.t DRAWING TITLE ° I I LEAK DETECTOR FOR DRAIN VALVE FLOOD PROTECTION PLUMBING DETAILS VALVE METAL DRAIN PAN DR LD MIN. 1715" SCALE AS SHOWN DEPTH 2" 3/4" PAN DRAIN DRAWN BY ARC TO FLOOR DRAIN GREATER THAN DIAMETER OF WATER HEATER DRAWN FOR TET CHECKED BY TET PROJECT# 20-021 FIREDGAS STORAGE TANK WATER HEATER DETAIL DATE (NOT TO SCALE) SHEET NO. . P-201 SHEET 2 OF 4 NO. REVISIONS DATE 4" VENT STACK 1 ISSUED FOR REVIEW 5/12/2020 EXI5TIN6 VENT UP THRU ROOF AND COORDINATION THRU ROOF 2 95% ISSUE 5/14/2020 I I ROOF I 3 COMPLETED 5/22/2020 I I CONSTRUCTION SET I 1 4 COMPLETED 6/04/2020 CONSTRUCTION SET 5 COMPLETED 6/12/2020 CONSTRUCTION SET 4" 6 ISSUED FOR PERMIT 7/07/2020 I 2-1/2" — " r--- -----I--------I--T--r--------------------- I------1------1-----, I-I/2" 2�� 4 ------�--------,----r-�'�--.r,— 2��� —�-- — --� 1-- --1 —T- J- LT----, I-I/2�� I 1-I/2" „J,I L�--_�---r-------- 1 2 1 I-1/2" ( —.—I— ----- I-1/2 I I/2I- —T"— — Ir 1— [/-2" I � „ � I-I/2 I 1-1/211I I-I/2 I I 1 RM 116 I RM lla RM 122 1 - „moi RM 125 IRM 121 I RM 12'1 RM 128 RM 12Q RM 130 "� ( 2 RM Ill I �I y EX. I I I EX. I I-I/2" I RM 123 I ( I I 1 2 I I RM 126 RM l0a RM lob RM 10-r � RM 105 � RM Io6 1 RM 103 LAV I EX. I EX.NO I LAV EX. 1 51G I 51G 1 5K I-I/2"-�) LAV I I/2 I SK I SK 1 RM 123 ( SK ( SK I SK I 1 RM III ( I LAV DF ( DF I SK ( SK I SK I SK ( SK I SK I SK C 7 I WG I WG I C 7 1 WG I I 1 I I I I I I I I 1 1 k c, I I I I I I I I I GROUND I — IF= 9_ ( — I JANITOR I 1 2.. 2.. 2.. I-I/2.. 2" 2" I 2„ ( SINK 1 2„ 2.1 �� „ �� " FLOOR I I _ I _ I I — 2° FD I 2 — I FD FD — 2 2 2 2 2 G.O. G.O. I G.O. I- - - — I t- - - 2" 4" 4 4 :;j 211 211 4" L J J � J J 4" O - -� - - - - - Z-) -1- - -1- - - - -� - - 4 4 NEW 4"5 CONNECTION " \-6�To EXISTING HOUSE DRAIN PLUMBING SANITARY RISER DIAGRAM AN C 1 1 ARCHITECTURE M U I N.T.S. CONSTRUCTION NEW 2"GW CONNECTION TO EXI5TIN6 GW SERVICE 222 Middle Country Rd. Suite 314 ROOF Smithtown, NY 11787 T: 631-979-0104 F: 631-979-3445 info@manciniarchitecture.com L3/4" — /-5/4 TEA 5/411 1" NEW GW I HW CONNECTION_&_\ ( 1 — — — — I 1" 5/4"-,,\ 3/4" TO EXIST]N6 BATHROOMS 1-1/4'1I Tangel Engineering Associates, P.C. I" l I 3/4 I" I" 3/4" 3/4" — — Consulting Engineers �j-- — 3/4" _ 3/4" — — 1 In IIf 3/411 I-I/4" I" - 3/4"J 3/4 I I 1 — 285 Middle Country Road,Suite 208 I/2° I 1 Smithtown,NY 11787" I 1/2" 1 1/2„ I-1/4" Phone:631.750.2800 1/2" I/2" 1/2" 1/2" Fax:631.750.2744 1/2" � I/2" V2" I/2" I/2" I/2" tangelengineering.com 51411-0/1 I 3/4" 1/211 r( r This drawing has been prepared for the indicated project and is an instrument of EX. EX. RM 118 RM Ila RM 122 RM 123 RM 125 RM 121 RM 127 RM 128 RM 12"1 RM 130 RM III RM 126 RM IOa RM 106 RM 1011 RM 105 RM 106 RM 103 service copyrighted by Mancini Architecture LAV 1=X. EX. LAV EX. 5K 5K 5K LAV 5K SK RM 123 SK SK 5K 5K I RM III LAV DF DF 5K SK 5K SK 5K 5K 5K PLLC. This drawing may not be copied or C 7 WC WG \7 WG L_� L—� �--.� C7 L_J L_J WG �--J �—� �--� `—J WH-1 JANITOR WG used, in whole or in part, by any party without GROUND F—:9 F—:9 F_—:9 SINK the expressed written consent of Mancini FLOOR = = = Architecture PLLC. Infringements or any use of this drawing for any other purposes will be prosecuted to the full extend of criminal law PLUMBING DOMESTIC WATER RISER DIAGRAM KEY PLAN 2 N.T.S. .:. RTU-1 RTU-I RTU-I 150 GFM 150 GFM 150 GFM ';` 'z` cti 6ri c I- - - - - -� I-- ---- -- ----� cSS1C 4' �Q®F,- spy 6 6 6G 2" 1-1/2 -11" 1-I/4" ROOF '\ C?--/7 PROJECT I STONY BROOK MEDICAL 10095 MAIN ROAD MATTITUCK, NY 11952 Ain KV NEW 2" CONNECTION TO 6AS METER. FURNISH AND INSTALL NEW 6A5 DRAWING TITLE PIPING TO NEW AC UNITS. REFER TO 6A5 RISER DIAGRAM PLUMBING RISER EXI5TIN6 6A5 METERS. DIAGRAMS MODIFY EXISTING MULTIPLE METER DETAIL A5 PER NATIONAL GtD APPROVED DETAILS TO 51N6LE METER SERVING NEW TENANT SCALE AS SHOWN 000 GFM) DRAWN BY ARC R M DRAWN FOR TET CHECKED BY TET PROJECT# 20-021 DATE --1-4---- FLOOR I SHEET NO. I PLUMBING GAS RISER DIAGRAM P-301 3 N.T.S. SHEET 3 OF 4 NO. REVISIONS DATE 1 ISSUED FOR REVIEW 5/12/2020 PLUMBING SPECIFICAT!ONS 23. VALVES: VALVES SHALL BE INSTALLED WHERE SHOWN ON THE DRAWINGS AND AS SPECIFIED AND PLUMBING LEGEND AND COORDINATION SHALL BE OF THE TYPE NOTED. VALVES 2"AND SMALLER SHALL HAVE SCREWED END. VALVES 1. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ALL REQUIRED BUILDING PERMITS AND LARGER THAN 2" SHALL HAVE FLANGED ENDS, GATE, GLOBE AND BALL VALVES SHALL BE INSTALLED FIXTURE SANITARY WASTE KENT HW GW &A5 2 95% ISSUE 5/14/2020 SHALL INCLUDE THE COST OF OBTAINING SUCH PERMITS IN HIS BID. WITH THE STEMS UPRIGHT AND WITHIN 15 DEGREES OF THE VERTICAL WHEREVER POSSIBLE. - - COL 0 HATER PIPING BUTTERFLY VALVES SHALL BE MOUNTED WITH THE STEM IN THE HORIZONTAL WHEREVER POSSIBLE 1-1/2" 1-1/2" 1/2" 1/2" 3 COMPLETED 5/22/2020 2.ALL WORK SHOWN IS DIAGRAMMATIC AND SHALL BE INSTALLED TO FIT ACTUAL BUILDING ALL VALVES SHALL BE TAGGED ITH BRASS NUMBERED TAGS, 1-1/2" DIAMETER . LAVATORY - - -- -- HOT WATER PIPING CONSTRUCTION SET CONDITIONS. THE CONTRACTOR SHALL INSPECT THE SITE PRIOR TO SUBMITTING HIS BID AND AND A. GATE VALVES 2"AND SMALLER SHALL BE CLASS 125 SWP, 200 WOG, RISING STEM, B-62 BRONZE SHALL FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS, THE CONTRACTOR SHALL INCLUDE IN BODY, BRONZE STEM, SOLID WEDGE, MEETING MSS SP80, WITH MALLEABLE IRON HANDWHEEL. HATER CLOSET 411 - 211 - 1/2" - --' HOT WATER RETURN PIPING 4 COMPLETED 6/04/2020 HIS BID ALL DEMOLITION AND DISPOSAL OF EXISTING FIXTURES, PIPING AND ACCESSORIES WHETHER ALUMINUM OR ZINC DIE CAST HAND WHEELS MAY NOT BE SUBSTITUTED. HAMMOND IB-640, OR EJ SEHA6E EJECTOR PIPING CONSTRUCTION SET SPECIFICALLY INDICATED ON THESE PLANS OR NOT. CONTRACTOR SHALL, AS PART OF CONTRACT, APPROVED EQUAL. SINK - 2" 1-1/2" 1/2" 1/2" - FURNISH ALL INCIDENTALS SUCH AS PIPES, FITTINGS, VALVES, HANGERS, ETC. AND AL1.,TESTING, A. GATE VALVES 2-1/2"AND LARGER SHALL BE CLASS 125 SWP, FLANGED END, CSAT IRON BODY, HASTE PIPING 5 COMPLETED 6/12/2020 CLEANING AND MISCELLANEOUS ITEMS NECESSARY TO LEAVE EACH SYSTEM COMPLETE IN EVERY BRONZE TRIM, OS&Y VALVES MEETING MSS SP70. STEM/WEDGE CONNECTIONS SHALL BE T-HEAD JANITOR SINK - 2" 1-1/2" 5/4" 5/4" - CONSTRUCTION SET DETAIL AND READY FOR OPERATION. CONNECTION. PINNED CONNECTIONS ARE NOT ACCEPTABLE. HAMMOND IR-904, OR APPROVED EQUAL. ----------------- VENT PIPING B. CHECK VALVES 2-1/2"AND SMALLER SHALL BE RATED CLASS 125 SWP, 5 DEGREE SWING CHECK 6 ISSUED FOR PERMIT 7/07/2020 3. THE CONTRACTOR SHALT_SCHEDULE ALL PLUMBING INSPECTIONS AND SHALL OBTAIN ALL TYPE MEETING MSS SP80. BODY AND CAP SHALL BE B-62 BRONZE. HAMMOND IR-904, OR CHECK BATHTUB - I/2" I/2" - G 6A5 PIPING APPROVALS AND FINAL SIGN-OFFS. VALVES 2-1/2"AND LARGER SHALL BE CLASS 125 SWP, FLANGED END CAST IRON BODY, BRONZE BALL VALVE TRIM SWING CHECK MEETING MSS SP71. HAMMOND IR-1124, OR APPROVED EQUAL 015HHASHER - I-I/2" - 1/2" - - 4. THE CONTRACTOR SHALL PREPARE AND SUBMIT FOR APPROVAL SHOP DRAWINGS OF ALL C. GLOBE VALVES 2"AND SMALLER SHALL BE CLASS 125 SWP, VALVES MEETING MSS SP80. BODY, --Q PIPE UP EQUIPMENT, MATERIALS, AND PIPING. BONNET AND STEM SHALL BE B-62 BRONZE. HANDWHEELS SHALL BE MALLEABLE IRON.ALUMINUM OR H05E BIBS - - - 1/211 - - ZINC DIE CAST HANDWHEELS ARE NOT ACCEPTABLE. GLOBE VALVES 2-1/2"AND LARGER SHALL BE J PIPE DOWN 5. THE CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES AND SHALL COOPERATE CLASS 125 SWP, FLANGED END, CAST IRON BODY, BRONZE TRIM MEETING MSS SP85. HAMMOND IR-116 AND ASSIST WITH THE DEVELOPMENT OF COORDINATED SHOP DRAWINGS. OR APPROVED EQUAL. KITCHEN SINK - 2" 1-1/2" 1/2" 1/2" D. BALL VALVES 2"AND SMALLER SHALL BE RATED FOR 150 SWP, 600 WOG MEETING WM35C TYPE II, GH>nGK VALVE 6. THE CONTRACTOR SHALL PREPARE AND SUBMIT AS-BUILT DRAWINGS INCLUDING FLOOR PLANS, CLASS A, STYLE 3. VALVES SHALL BE TWO PIECE THREADED BODY, SOLID OR TUNNEL DRILLED, LARGE LAUNDRY - 2" 1-1/2" 1/2" 1/2" RISER DIAGRAMS, A VALVE TAG SCHEDULE,AND EQUIPMENT, FIXTURE AND MATERIAL RECORD PORT, CHROME BALL. SEATS AND SEALS SHALL BE TEFLON, STEM SHALL BE OF BLOWOUT PROOF 6A.TE VALVE DRAWINGS, DESIGN UNDER FULL WORKING PRESSURE WITH HANDLE OR HANDLE NUT REMOVED. HAMMOND 8501, FLOOR DRAIN - 5" I-I/2" - - - OR APPROVED EQUAL. ww�r' 7. THE CONTRACTOR SHALL COORDINATE THE LOCATIONS OF ALL ACCESS DOORS FOR VALVES AND I-I/2" W GAS GOG 2" K ITEMS REQUIRING ACCESS. 24. THE CONTRACTOR SHALL FURNISH AND INSTALL A NEW HOT WATER RECIRCULATING PUMP AT THE FLOOR SINK - - T . - EXISTING (TO BE RELOCATED) ELECTRIC WATER HEATER IN ALL MECHANICAL EQUIPMENT ROOM. THE 8. THE CONTRACTOR SHALL FURNISH AND INSTALL VACUUM BREAKERS AND NECESSARY BACKFLOW PUMP SHALL BE SIMILAR TO"TACO"ALL BRONZE, FLANGED RED BARON CIRCULATOR MODEL#111, 2 THERMOMETER PREVENTION AT ICE MACHINES AND WATER DISPENSERS. GPM @11.0 FT HD. 9. THE CONTRACTOR SHALL INCLUDE IN HIS PRICE ALL NECESSARY WORK REQUIRED TO INSTALL 25. THE CONTRACTOR SHALL FURNISH AND INSTALL A NEW POTABLE WATER EXPANSION TANK IN ALL I PRESSURE 6AU6E DRAINAGE AND VENT PIPING BELOW FINISHED FLOORS WHERE REQUIRED. MECHANICAL EQUIPMENT ROOMS. THE EXPANSION TANK SHALL BE SIMILAR TO"FLEXCON" MODEL WH-8. PIPING VOLUME AND MAXIMUM P I P I NC LENGTHS OCINI 10. ALL WORK PERFORMED ON FLOORS NOT CONCURRENTLY UNDER CONSTRUCTION SHALL BE FREEZE PROOF HALL HYDRANT PERFORMED DURING OVERTIME HOURS. ALL CEILINGS, WALLS ETC.. SHALL BE REPAIRED OR MA1\4 REPLACED PRIOR TO THE START OF THE NEXT WORK DAY, ALL AFFECTED AREAS MUST BE CLEANED PLUMBING NOTES: MAXIMUM PIPING LENGTH (FEET) PRIOR TO THE START OF THE NEXT WORK DAY. ALL WORK PERFORMED ON TFLOORS NOT CURRENTLY NOMINAL PIPE SIZE VOLUME (LIQUID DIELECTRIC UNION ARCHITECTURE UNDER CONSTRUCTION MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 1. WORK SHALL BE PERFORMED IN ACCORDANCE WITH NYS BUILDING CODE REQUIREMENTS AND ANY (INCHES) OUNCES PER FOOTmul ADMINISTRATIVE LAWS, ORDINANCES OR RECOMMENDATIONS OF ANY DEPARTMENT HAVING LENGTH) PIPING LAVATORY FAUCETS OTHER FIXTURES AND 104C WATER CLOSET CONSTRUCTION 11. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL FINAL CONNECTIONS FOR COLD WATER, HOT JURISDICTION. APPLIANCES WATER, GAS, WASTE,VENT, AND INDIRECT WASTE TO ALL PLUMBING FIXTURES AND KITCHEN 5K SINK 222 Middle Country Rd. Suite 314 EQUIPMENT. ALL INDIRECT WASTES SHALL BE PROPERLY PITCHED AND SHALL RUN TO THE NEAREST 1/2 1.5 2 45 Smithtown, NY 11787 FLOOR DRAIN OR OTHER FIXTURE WITHOUT CAUSING A TRIP HAZARD OR OBSTRUCTION TO USE OR 2. PROTECTION OF PIPING AS OUTLINED IN NYS BUILDING CODE PC305 SHALL BE PROVIDED AS LAV LAVATORY T: 631-979-0104 SERVICING OF EQUIPMENT. REQUESTED. F: 631-979-3445 3/4 3 OS 21 � FLOOR DRAIN WSELF 12. ALL PIPING SHALL BE CONCEALED IN WALLS, FLOORS AND CEILINGS. ALL WALLS SHALL BE CHASED 3. ALL PIPING AND MATERIALS SHALL BE AS APPROVED IN NYS BUILDING CODE PC605. PRIMER TRAP info@manciniarchitecture.com TO ACCOMMODATE NEW PIPING AND SHALL BE REPAIRED. 4. PIPING JOINTS AND CONNECTIONS SHALL BE AS APPROVED IN NYS BUILDING CODE PC605. 1 5 0.5 15 HN HOT HATER 13. ALL PIPE PENETRATIONS THROUGH FLOOR SLABS SHALL BE CORE DRILLED WITH ADEQUATE SPACE AROUND PIPE TO Al-LOW CONTINUOUS INSULATION TO PASS THROUGH FLOORS. ALL PIPE 5. TRAPS AND CLEANOUTS SHALL BE AS PER NYS BUILDING CODE PC708& PC1002. CIN COLD WATER PENETRATIONS THROUGH FLOORS SHALL BE SEALED AND WATERPROOFED 1-1/4 6 OS 6 6. CONSTRUCTION AND SPACING OF HANGERS SHALL BE AS DIRECTED IN NYS BUILDING CODE PC308. HHR HOT HATER RETURN 14. PLUMBING FIXTURES: THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NEW PLUMBING FIXTURES AND APPLIANCES. ALL PLUMBING FIXTURES INCLUDING BUT NOT LIMITED TO WATER 7. WATER SUPPLY SYSTEM,VALVES AND TESTS SHALL BE AS DIRECTED IN NYS BUILDING CODE PC 1-1/2 II 0.5 6 5 SANITARY CLOSETS, LAVATORIES, KITCHEN SINKS, ETC AND APPLIANCES SHALL BE AS SPECIFIED BY THE CHAPTER 6. TEA ARCHITECT. REFER TO ARCHITECT'S SPECIFICATIONS. ALL FIXTURES SHALL BE SUBMITTED TO THE W HASTE aq ARCHITECT AND THIS ENGINEER FOR APPROVAL TO ASSURE CONFROMANCE TO SPECIFICATIONS, 8. SANITARY DRAINAGE PIPING, SIZING, GRADING AND OFFSETS SHALL BE AS OUTLINED IN NYS 2 OR LARGER 16 OS 4 V VENT COMPATIBILITY WITH FLOOR AND WALL CONSTRUCTION, WATERPROOFING, FINISHES AND OVERALL BUILDING CODE PC CHAPTER 7. QUALITY. Tan_gel Engineerinq Associates, P.C. 9.VENT SIZING, GRADING, CONNECTIONS, LOCATIONS AND OFFSETS AS DIRECTED IN PC CHAPTER 9. THE MAXIMUM ALLOWABLE PIPIN6 LENGTH FROM THE NEAREST SOURCE OF HEATER HATER TO THE FV PUMP D15GHARSE Consulting Engineers TERMINATION OF THE FIXTURE SUPPLY PIPE SHALL BE IN ACCORDANCE WITH THE FOLLOHIN6. WHERE THE 15. ALL SANITARY AND WASTE PIPING SHALL NO-HUB CAST IRON SOIL PIPE AND FITTINGS. 10, ALL SANITARY AND WASTE PIPING OFFSETS SHALL BE INSTALLED, AND CONNECTIONS MADE SO AS PIPIN6 CONTAINS MORE THAN ONE SIZE OF PIPE. THE LARGEST SIZE OF PIPE WITHIN THE PIPIN6 SHALL BE HDGP HANDICAPPED ACCESSIBLE TO AVOID SUDS PRESSURE ZONES AS DIRECTED IN NYS BUILDING CODE PC704.6. USED FOR DETERMINING THE MAXIMUM ALLOWABLE LENGTH OF THE PIPIN6 IN TABLE ABOVE. ONLY THE NOMINAL PIPIN5 SIZES LISTED ABOVE SHALL BE USED ON THIS PROJECT. Middle Country Road,suite 208 Smithtown, 16. VENT PIPING SHALL BE NO-HUB CAST IRON SOIL PIPE AND FITTINGS OR GALVANIZED STEEL PIPE FAI FRESH AIR INLET Smithtown,NY 11787 WITH MALLEABLE IRON FITTINGS. 11. ALL SEWAGE EJECTORS SHALL BE INSTALLED AS Phone:631.750.2800 PER NYS PLUMBING CODE PC712. Fax:631.750.2744 17, WATER PIPE SHALL BE "TYPE"L"COPPER TUBING WITH BRAZED JOINTS. FD FLOOR DRAIN tangelengineering.com 12. ALL STORM DRAINAGE PIPING SHALL BE INSTALLED AS PER NYS BUILDING CODE PC CHAPTER 11. HEATED WATER SUPPLY PIPING MAXIMUM LEN6TH5 0.0 18. INSULATION O GLEAN OUT ALL HOT WATER, COLD WATER AND HOT WATER RETURN PIPING SHALL BE INSULATED WITH 1"THICK 13. ALL NATURAL GAS PIPING SHALL BE INSTALLED IN ACCORDANCE WITH NYS FUEL GAS CODE. This drawing has been prepared for the MOLDED FIBERGLASS INSULATION WITH FOIL VAPOR BARRIER, INSULATION SHALL BE CONTINUOUS MAXIMUM PIPIN6 LENGTH (FEET) indicated project and is an instrument of THROUGH ALL BRACKETS, HANGERS, SUPPORTS, WALL PENETRATIONS, FLOOR SLAB PENETRATIONS; 14.ALL NEW DOMESTIC WATER PIPING SHALL BE DISINFECTED AFTER INSTALLATION AS PER NYS NOMINAL PIPE: SIZE VOLUME (LIQUID HATER HEATER service copyrighted by Mancini Architecture ETC. ALL SEAMS SHALL BE TAPED AND/OR SEALED TO PROVIDE TIGHT VAPOR BARRIER. TRAPS AND BUILDING CODE SECTION PC-610. OUNCES PER FOOT PLLC. This drawing may not be copied or VALVES UNDER HANDICAPPED ACCESSIBLE LAVATORIES SHALL BE INSULATED WITH PRE-MOLDED (INCHES) LENGTH) OTHER FIXTURES AND used, in whole or in art, b an VAPOR SEALED INSULATION SIMILAR TO"TRU-BRO". INSULATION WILL BE IN ACCORDANCE WITH THE 15. GAS FIRED CONDENSING WATER HEATER WH-1 PIPIN6 LAVATORY FAUCETS p y y party without ( ) APPLIANCES the expressed written consent of Mancini GAS FIRED CONDENSING WATER HEATER SHALL BE SIMILAR TO"AO SMITH"VERTEX MODEL GDHE-50, Architecture PLLC. Infringements NYC ENERGY CONSTRUCTION AND CONSERVATION CODE. THE INSULATION THICKNESS FOLLOW THE M❑ 6A5 METER or any use CODE AND/OR THESE SPECIFICATIONS, WHICHEVER IS MORE STRINGENT. 50 GALLON, 96%THERMAL EFFICIENCY, 129 GPH RECOVERY RATE AT 90 F DEGREES RISE, 100,000 BTUH of this drawing for any other purposes will be GAS INPUT, 22" DIAMETER X 66-3/4" HEIGHT, 225 LBS. ENERGY STAR QUALIFIED , ASME RATED T&P I/2 IS 2 43 prosecuted to the full extend of criminal law 19. FLOOR CLEANOUTS RELIEF VALVE. MAX HYDROSTATIC WORKING PRESSURE 150 PSI, "BLUE DIAMOND" GLASS COATING FLOOR CLEANOUTS SHALL BE SIMILAR TO"JAY R. SMITH"4100 SERIES. CLEANOUTS SHALL BE MADE WITH TWO HEAVY DUTY ANODES. 3/4 5 0.5 21 OF DUCO CAST IRON WITH ROUND ADJUSTABLE SCORIATED SECURED NICKEL BRONZE TOP. ALL 6F 6A5 FURNACE 16. THERMOSTATIC MIXING VALVES KEY PLAN CLEANOUTS IN CONCRETE FLOOR SHALL HAVE SPIGOT TYPE OUTLETS. NO-HUB MAY BE USED ONLY ALL LAVATORIES SHALL HAVE POINT-OF-USE THERMOSTATIC MIXING VALVES, LIMITING THE HOT ON EXPOSED PIPING. WATER TEMPERATURE TO 110 DEGREES MAXIMUM. THERMOSTATIC MIXING VALVES SHALL BE SIMILAR 1 5 OS 15 0 - NEtq,� 20. FLOOR DRAINS TO "POWERS" LFLM495 POINT OF USE THERMOSTATIC MIXING VALVE, LEAD-FREE BRASS FLOOR DRAINS SHALL BE SIMILAR TO"JAY R. SMITH"2110 WITH 8-1/2" ROUND TOP. FLOOR DRAINS BODY, ADJUSTABLE TEMPERATURE SELECTION WITH LOCK DOWN, INTEGRAL CHECK AND RTU o o�v F_ SHALL BE MADE OF DUCO CAST IRON BODY AND FLASHING COLLAR WITH NICKEL BRONZE TOP. SCREEN PREVENTS CROSS-FLOW AND CONTAMINATION, TEMPERATURE ADJUSTMENT I-I/4 6 0.5 6 ROOFTOP AG UNIT �� NO-HUB OUTLETS MAY NOT BE USED ON CONNECTIONS BELOW CONCRETE FLOOR SLAB. SIZES SHALL RANGE 80.6 °F{27°C)TO 120.2 °F (49 °C), TEMPERATURE CONTROLS TO ASSE 1069 11070 DOWN TO 0.5 US GAL(1.9 L). fni5 II' =` :_ . Li I BE AS INDICATED ON THE DRAWINGS AND SHALL IN NO CASE BE SMALLER THAN 3" NOMINAL PIPE SIZE. PROVIDE TEE,ADAPTORS AND FLEX. COPPER TUBING TO SUIT INSTALLATION. I-I/2 II OS 6 NEW CONNECTION TO EXISTINGI�. PROVIDE FUNNELS AND SPECIAL GRATES AS INDICATED ON PLANS. (P PROVIDE TEMPERED WATER TO HOT SIDE OF FAUCET. 21. FUNNEL DRAINS 2 OR LARGER 16 OS 4 DF FLOOR DRAIN FUNNEL DRAINS SHALL BE SIMILAR TO"JAY R. SMITH" 3800 SERIES AND SHALL BE MADE OF DUCO 17, GAS WATER HEATER VENT AND AIR INLETS ESSIO Cad CENTROTHERM 'INNOFLUE' 5W 3" DIA PIPE, FLUE OUTLET CONNECTOR: 15AGLO303, ADAPTER COATED CAST IRON. SIZES SHALL BE AS INDICATED ON PLANS. CONNECTOR. 1AFC03, RING CONNECTOR: 1ANS03, 90 DEGREE ELBOW: 15ELL0387, VENT MATERIAL: HEATED WATER SUPPLY PIPIN6 FOR THIS PROJECT SHALL BE IN AGG "EFFICIENT TO NYS EGG 405 EFFICIENT 22. WATER HAMMER ARRESTORS 15VL03, TERMINALS: EXHAUST: 15VL03 AND 1ASD803, INTAKE-----ONLY: 15ELL0387 AND 1ASPP03 HEATED WATER SUPPLY PIPIN6". WATER HAMMER ARRESTORS SHALL BE SIMILAR TO "PRECISION PLUMBING PRODUCTS" MODEL THE MAXIMUM ALLOWABLE PIPIN6 LENGTH FROM THE NEAREST SOURCE OF HEATER WATER TO THE SWA-750 OR SWA-1000 AS [REQUIRED. WATER HAMMER ARRESTORS SHALL BE MADE OF TYPE K TERMINATION OF THE FIXTURE SUPPLY PIPE SHALL BE IN ACCORDANCE HITH THE FOLLOHIN6. WHERE THE COPPER AND SHALL HAVE SWEAT CONNECTIONS. ARRESTORS SHALL BE RATED FOR 250 PSIG PIPIN6 CONTAINS MORE THAN ONE SIZE OF PIPE. THE L.AR6E5T SIZE OF PIPE WITHIN THE PIPIN6 SHALL BE WORKING PRESSURE AND 1000 PSIG SPIKE PRESSURE, ARRESTORS SHALL BE MAINTENANCE FREE. USED FOR DETERMINING THE MAXIMUM ALLOWABLE LENGTH OF THE PIPIN6 IN TABLE ABOVE. ONLY THE PROJECT ARRESTORS SHALL BE INSTALLED ON EVERY HOT WATER AND COLD WATER BRANCH TAKEN FROM NOMINAL PIPIN6 SIZES LISTED ABOVE SHALL BE USED ON T14I5 PROJECT. THE RISERS TO SERVE A FIXTURE OR BATTERY OF FIXTURES. STONY BROOK AFFL I GABLE 00DE5: PIPING INSULATION SCHEDULE MEDICAL 10095 MAIN ROAD PLANS THAT ARE IN CONFORMANCE OF THESE APPLICABLE GORES: MATTITUCK, NY 11952 FLUID OPERATING INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE • 2017 NEW YORK STATE UNIFORM CODE; USE CROUP R-2 PIPE SERVICE TEMPERATURE (INCHES) DRAWING TITLE • 2017 NEW YORK STATE CODE SUPPLEMENT (PUBLISHED JULY, 2017 EFFECTIVE OCTOBER 51, 2017RANGE 4 USAGE). (OF) CONDUCTIVITY MEAN RATING <I• I TO 1-1/2 4 TO � • 2017 NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE. (BTU IN✓H FT F) TEMPERATURE ( F) <1-1/2 To <4 <6 • 2017 NY5 BSC SUPPLEMENT TO THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION GODS PLUMBING (PURL I GAT I ON DATE: JULY 2017, EFFECTIVE OCTOBER 51, 201-1). COLD WATER 40-60 0.21 - 0.2"1 "75 0.5 OS 1.0 1.0 1.0 SPECIFICATIONS • 2016 NY550 (2015 TBG 5RD PRINTING). 2016 NY5RC (2015 IRC 2ND PRINTING). HOT HATER 120-140 0.21 - 0.28 100 1.0 1.0 1.5 1.5 IS • 2016 NYSEC (2015 IEGC 2ND PRINTING). HOT HATER SCALE AS SHOWN • 2016 NYSPG (2015 IPG 3RD PRINTING). RE-GIRGULATION 100-120 0.21 - 0.28 100 I.O I.O IS IS IS DRAWN BY ARC • 2016 NY5MC (2015 IMG 5RD PRINTING). DRAWN FOR TET • 2016 NY5FC (2015 IFC 3RD PRINTING). PIPIN6 INSULATION EXPOSED TO THE HEATHER SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT DUE TO SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE AND HIND, AND SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE CHECKED BY TET • 2016 NY5PM0 (2015 IPMC 4TH PRINTING). DEGRADATION OF THE MATERIAL. ADHESIVE TAPE SHALL NOT BE PERMITTED. ALL EXTERIOR PIPIN6 SHALL BE COVERED HITH A PROJECT# 20-021 • A5HRAE Q0.1 2015 (JULY 2014 PRINTING). PVC OR ALUMINUM VAPOR BARRIER JACKET, OR ALTERNATIVELY PLACED IN A HEATHER RES15TANT ENCLOSURE, SUCH AS PIPE • TITLE IC1 NYCRR PARTS 1220 THROUGH 1228, 1240, 1264, AND 1265 AND PART 500 (ACCESSIBILITY RACK WITH A TOP COVER. DATE 5TORA6E). SHEET NO. P-501 SHEET 4 OF 4 NO. REVISIONS DATE GENERAL CONDITIONSE D 1Q RDTbEINguIZFd TOWN 8/12/20 11) 1-11% =7 M N rEv 1. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE PROVISIONS OF THE NEW YORK T NY 1 . 1 STATE BUILDING CODE, AND BUILDING & ZONING CODES OF THE LOCAL GOVERNING TOWN OR MUNICIPALITY. REQUIREMENTS SPECIFIED IN THE CODE SHALL BE ADHERED TO AS IF CALLED FOR OR SHOWN ON THE DRAWINGS. ANY REQUIREMENTS SET FORTH ON THE DRAWING MORE M A I rk 1 0 STRINGENT THAN CODE ARE TO BE FOLLOWED AND NOT MODIFIED WITHOUT THE ARCHITECT'S PERMISSION. WORKMANSHIP SHALL CONFORM TO THE BEST ACCEPTABLE STANDARDS FOR THE 10095 A INI M AU TRADES INVOLVED. 2. ARCHITECTURAL SERVICES FOR THIS PROJECT ARE LIMITED TO THE PREPARATION OF THESE PLANS (GENERAL. CONSTRUCTION PLANS) CONFORMING WITH THE BUILDING CODE REQUIREMENTS. THE ARCHITECT IS AVAILABLE TO THE OWNER OR CONTRACTOR FOR CONSULTATION REGARDING THE INTENT OF THESE PLANS. ANY DEVIATION FROM THE PLANS MAm TTITUCK NY 11952 SHALL BE REPORTED TO THE ARCHITECT, IN WRITING, PRIOR TO COMMENCEMENT OF THE NO. ISSUED DATE WORK. ^'� / / 1 80% COMPLETION SET 4/16/20 3. ALL WORK SHALL BE EXECUTED IN SUCH A MANNER AS TO PROTECT THE SAFETY OF (v^ WORKERS AND THE PUBLIC. BARRIERS AND OTHER PRECAUTIONARY MEASURES SHALL BE SITE DATA: ERECTED IN ACCORDANCE WITH THE AUTHORITIES HAVING JURISDICTION OR AS REQUIRED FOR >0000, TAX MAP NO.: 1000-142-01 -26 / ° 2 95% COMPLETION SET 5/14/20 SAFETY DURING THE ENTIRE CONSTRUCTION OPERATION. �V 3 COMPLETED CONST. SET 5/22/20 4. CONTRACTOR SHALL VERIFY ALL CONDITIONS COVERING OR AFFECTING THE STRUCTURAL ♦ / J ZONING: GENERAL BUSINESS 4 COMPLETED CONST. SET 6/4/20 WORK, OBTAIN ALL DIMENSIONS TO INSURE PROPER STRENGTH, FIT AND LOCATION OF STRUCTURAL WORK; AND REPORT TO THE ARCHITECT ANY AND ALL CONDITIONS WHICH MAY / SITE AREA: 381,150 SQ. FT. (8.75 ACRES) 5 COMPLETED CONST. SET 6/12/20 INTERFERE WITH OR AFFECT PROPER EXECUTION AND COMPLETION OF THE NEW WORK. THE / 0-' BUILDING AREA: 000 SQ. FT. 6 ISSUED FOR PERMIT 7/7/20 ARCHITECT IS TO BE NOTIFIED OF ANY AND ALL CHANGES. CONST. TYPE: IIB 5. THIS BUILDING SHALL CONFORM TO THE AMERICAN NATIONAL STANDARD FOR BUILDINGS, AND c� .p. FACILITIES; PROVIDING ACCESSIBILITY AND USABILITY FOR PHYSICALLY HANDICAPPED / / -10 O `� PROJECT INFORMATION: `� PEOPLE, ANSI A'117.1-2009. ALL COMPONENTS OF THIS BUILDING, WHETHER EXPLICITLY •o. '�� Stony Brook Medicine STATED OR NOT, SHALL BE BARRIER FREE DESIGNS AS REQUIRED FOR PHYSICAL / HANDICAPPED ACCESSIBILITY. 00 110INTERIOR ALTERATION TO 3 EXISTING SUITES. 6. CONTRACTOR SHALL REPAIR ALL DAMAGED AND DISTURBED SURFACES AND AREAS TO THEIR / p o- 41. TOTAL WORK AREA: 4980 SQ.FT. ORIGINAL CONDITION, RESULTING FROM CONSTRUCTION, IN EXISTING AREAS. 7. CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY AND/OR PERMANENT SUPPORT, BRACING, SHORING, ETC., AS REQUIRED FOR THE SAFE INSTALLATION OF NEW CONSTRUCTION. MANCINI 8. CONTRACTOR TO ALIGN ALL NEW CONSTRUCTION WITH EXISTING WALLS AND ROOF LINES AS INDICATED. PATCH EXISTING SURFACES AS REQUIRED TO A SMOOTH FINISH WITH ADJACENT � / NEW CONSTRUCTION. ° / o, SEP - �� 0 ARCHITECTURE 9. WORK WHICH REQUIRES PATCHING SHALL BE DONE WITH THE SAME MATERIALS AND IN THE >00000, NO, mul CONSTRUCTION SAME MANNER AS ADJOINING WORK. ALL DUE PRECAUTIONS SHALL BE TAKEN TO INSURE lJ / , BONDING BETWEEN OLD AND NEW WORK. JOINING BETWEEN OLD AND NEW WORK SHALL BE A SMOOTH CONTINUOUS FINISH TO ELIMINATE ANY VISUAL EVIDENCE OF JOINING. / 18� ' 222 Middle Country Rd, Suite 314 10. CONTRACTOR SHALL PRESENT THE BUILDING TO THE OWNER FOR ACCEPTANCE CLEAN AND �' Smithtown, NY 11787 READY FOR OCCUPANCY. ALL DEBRIS IS TO BE CONTAINED IN DUMPSTERS OR TRUCKS AND / / �gp T. 631-979-0104 CARTED AWAY FROM THE SITE. CONTRACTOR IS RESPONSIBLE FOR LEGAL DISPOSAL OF ALL �o F: 631-979-3445 ITEMS TAKEN FROM THE SITE. r, �0 info@manciniarchitecture.com 11. RENTAL CHARGES, SAFETY, PROTECTION AND MAINTENANCE OF RENTED EQUIPMENT SHALL BE �. THE CONTRACTOR'S RESPONSIBILITY. �'a, � 0 12. CONSTRUCTION SAFETY, INCLUDING CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, COMPLIANCE WITH STATE AND FEDERAL REGULATIONS REGARDING SAFETY SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 13. ALL MATERIALS USED TO COMPLETE RENOVATION WORK ARE TO BE NEW. SALVAGED MATERIALS MAY BE USED UNDER CERTAIN CONDITIONS SUBJECT TO ARCHITECT OR OWNER'S0 �' `SO APPROVAL. $Z PROJECT LOCATION o 5�5 0, 14. ALL DEMOLITION WORK TO BE RESTRICTED TO AREAS SHOWN ON THE PLAN. CARE IS TO BE TAKEN NOT TO DISTURB ADJACENT WALLS, CEILING OR STRUCTURE TO REMAIN. 6�2 / / 15. ANY STRUCTURAL_ MEMBERS ENCOUNTERED DURING DEMOLITION ARE TO REMAIN UNLESS /> DIRECTED TO BE REMOVED BY THE ARCHITECT. PROVIDE TEMPORARY SHORING OR SUPPORTS do / AS REQUIRED. 16. CONTRACTOR SHALL FURNISH THE USUAL TRADE GUARANTEES, GUARANTEEING ALL MATERIALS AND WORKMANSHIP AGAINST ORIGINAL DEFECTS AND AGAINST INJURY FROM '�� ,�p52 Vdr. PROPER, USUAL WEAR, WHEN USED FOR THE PURPOSE INTENDED FOR A PERIOD OF ONE YEAR AFTER COMPLETION OF THE WORK OF THIS CONTRACT. THE PERIOD OF ONE YEAR 12 4, O , R ` BEGINS ON THE DATE OF FINAL PAYMENT. DEFECTS APPEARING DURING THAT YEAR SHALL BE MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE. 17. TEMPORARY STORAGE AND PROTECTION OF TOOLS, EQUIPMENT, AND MATERIALS SHALL BE THE CONTRACTORS RESPONSIBILITY. 18. PERFORM DEMOLITION, ALTERATION AND REMODELING WORK INDICATED TO PRODUCE FINISHED i" This drawing has been prepared for the RESULTS SHOWN AND DESCRIBED ON THE DRAWINGS. THE CONTRACTOR SHALL COORDINATE indicated project and is an instrument of ALL REMODELING WORK AND SHALL BE RESPONSIBLE FOR DIVISION OF WORK BETWEEN THE service copyrighted by Mancini Architecture � VARIOUS SUBCONTRACTORS. � / DRAWING LIST PLL his yawing may not a copse or 19. UNFINISHED SURFACES CREATED BY REMOVAL OF EXISTING MATERIALS AND SURFACES / used, in whole or in part, any party without DAMAGED OR DISTURBED BY REMODELING WORK SHALL BE PATCHED WITH NEW MATERIALS ?° +h the expressed written consent of Mancini ARCHITECTURAL Architecture PLLC. Infringements or any use AND FINISHED TO MATCH THE EXISTING WORK. aof this drawing for any other purposes will be GENERAL NOTES: � T-100 TITLE SHEET AND BUILDING INFORMATION l;R. �y> prosecuted to the full extend of criminal law / / NS APPROVALS % T-200 STANDARD ACCESSIBLE CODES & DETAILS KEY PLAN 1. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING ALL INSPECTIONS, �� �j �'� CERTIFICATES, CERTIFICATES OF OCCUPANCY OR COMPLETION, U.L. APPROVALS, AND ANY OTHER MUNICIPAL REQUIREMENTS. � / A-001 CODE SHEET & EGRESS PLAN 2. ALL DISCREPANCIES REGARDING THE DESIGN AND DRAWINGS ARE TO BE IMMEDIATELY Z Z / C-)' BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY BEFORE PROGRESSING FURTHER G z 4 - A-010 DEMOLITION FLOOR PLAN WITH ANY AND ALL WORK. 3. THE DRAWING IS NOT TO BE SCALED AND ALL DIMENSIONS ARE TO BE VERIFIED BY THE / O A-100 PROPOSED FLOOR PLAN CONTRACTOR. �j _ A-101 PROPOSED FURNITURE & EQUIPMENT PLAN CONTRACTOR PERFORMANCE: A\ / � �O �\ 1. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS OF CONSTRUCTION. NO , _\ �P A-101 PROPOSED R EFLECTED CEILING PLAN DETAIL INCLUDED HEREIN IS MEANT TO SUBSTITUTE FOR THE CONTRACTOR'S KNOWLEDGE AND �j EXPERIENCE OF THE PROPER PREPARATION, TOOLING, SCHEDULING, PROCEDURES, LIMITATIONS, o A-300 PROPOSED FINISH PLAN AND REQUIREMENTS OF THE MATERIALS TO BE INSTALLED. �J /� 2. THE CONTRACTOR AND SUB-CONTRATOR(S), ARE ALL REQUIRED TO PERFORM A PRE-BID SITE Z "6�p ro•/ / ti / A-400 INTERIOR OR ELEVATIONS INSPECTION ALONG WITH A COMPLETE REVIEW OF THE DRAWINGS AND SPECIFICATIONS OF THE 00- / PROJECT PROJECT. 7s-. A-401 INTERIOR ELEVATIONS STONYBROOK 3. THE CONTRACTOR SHALL INDICATE ALL EXCEPTIONS TO THE DESIGN IN HIS BID DOCUMENT. / ,� 11-1 NO CONTRACTOR EXCEPTIONS SHALL BE ACCEPTED BY THE OWNER OR HIS DESIGNEE A-410 MILLWORK SECTIONS MEDICINE WITHOUT FULL WFZITTEN APPROVAL OF THE ARCHITECT AND ENGINEER. 10095 MAIN ROAD 4. THE CONTRACTOR'S WORKMANSHIP IS TO BE OF THE HIGHEST GENERALLY ACCEPTED ��� ��� MATTITUCK, NY 11952 STANDARD IN THE INDUSTRY AND LACK OF PERFORMANCE IN ANY NATURE BY THE A-500 CONSTRUCTION DETAILS CONTRACTOR WILL. BE DEEMED A VIOLATION OF HIS CONTRACT. 5. THE CONTRACTOR SHALL PROVIDE A FULL WARRANTY FOR ALL MATERIALS AND WORKMANSHIP A-600 SCHEDULES DRAWING TITLE PROVIDED. THE WARRANTY LENGTH SHALL BE AS SO NEGOTIATED BETWEEN THE OWNER AND N CONTRACTOR. PLOT PLAN MECHANICAL PLOT PLAN & FINISH NOTES 1 M-101 MECHANICAL PLAN 1 "=501PROJECT INFO. GYPSUM BOARD M-201 MECHANICAL DETAILS 1. GYPSUM BOARD :SHALL BE 5/8" THROUGHOUT UNLESS NOTED OTHERWISE ON THE DRAWINGS M-401 MECHANICAL SCHEDULES OR SPECIFICATIONS. FASTEN AT 8" O.C. FOR WALL APPLICATIONS. METAL CORNER BEADS M-501 MECHANICAL SPECIFICATIONS SCALE SCALE AS SHOWN SHALL BE USED AT ALL OUTSIDE CORNERS. ALL JOINTS SHALL BE TAPED, SPACKLED AND DRAWN BY ML SANDED SMOOTH, POLISHED AND READY FOR PAINTING. E-101 ELECTRICAL POWER PLAN DRAWN FOR -- 2. GYPSUM BOARD IN RATED WALLS INDICATED ON THE PLANS SHALL BE 5/8" TYPE "X" GYPSUM BOARD AS REQUIRED BY CODE. E-102 ELECTRICAL LIGHTING PLAN CHECKED BY MM 3. GYPSUM BOARD SHALL BE AS MANUFACTURED BY GEORGIA PACIFIC, OR APPROVED EQUAL, E-401 ELECTRICAL PANEL SCHEDULE & DETAIILS PROJECT# AND SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH MANUFACTURES DATE 3/9/2020 RECOMMENDATIONS. E-501 ELECTRICAL SPECIFICATIONS 4. IN WET AREAS AND UNDER CERAMIC TILE WALL FINISHES, USE 7/16" WONDER BOARD SHEET NO. INSTALLED IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS. P-101 PLUMBING PLAN PAINTING P-201 PLUMBING DETAILS T- 1 00 1. GYPSUM BOARD WALLS SHALL RECEIVE ONE COAT OF PRIMER SEALER AND A MINIMUM OF P-301 PLUMBING RISER DIAGRAMS TWO COATS OF LATEX WALL PAINT UNLESS NOTED ON THE DRAWINGS. APPEARANCE P-501 PLUMBING SPECIFICATIONS RATHER THAN NUMBER OF COATS DETERMINE ACCEPTANCE OF FINISH SURFACE. PAINT SHALL _ BE BY BENJAMIN MOORE OR APPROVED EQUAL. SEE CORPORATE DESIGN MANUAL FOR COLOR SELECTION AND LOCATION ---- SHEET OF NO. REVISIONS DATE 10 ADDENDUM 1 8/12/20 NEW 1 J" FURRING METAL " GYP. BOARD STUDS AT 16" O.C. 3 METAL STUDS @ 16" O.C. I VERTICAL LEVEL LINE: CONTRACTOR TO � I � (1) LAYER J" GYPSUM ENSURE BAR IS LEVEL I ' NO. ISSUED DATE N BOARD — BOTH SIDES � � EXISTING DOOR FLANGE COVER 1 80% COMPLETION SET 4/16/20 i I TO REMAIN i i I I 2 95% COMPLETION SET 5/14/20 EXISTING CMU WALL i „ ALUMINUM SHIM PLATE NEW 1g� METAL STUDS ON I 3 COMPLETED CONST. SET 5/22/20 INSIDE CORNER OF OPENING ' I I 4 COMPLETED CONST. SET 6/4/20 WC-1 TO BE WRAPPED ' i I MANUFACTURER MOUNTING FURRING OVER DOOR /WINDOW AROUND OPENING TO EN - _-- J I PLATE 5 COMPLETED CONST. SET 6/12/20 0 6ON INSIDE CORNER 6 ISSUED FOR PERMIT 7/7/20 ``"`����------- -- -- 1 -1 /2"-1 '-0" I 2 X BLOCKING AT ALL BAR MOUNTING LOCATIONS WALLPAPER DETAIL. � � d��\ Stony Brook Medicine 04 3"=1 '—�" I I 18" X 4" VERTICAL BAR I I II II / I I SCHLUTER (SEE FINISH PLAN & BATHROOM ELEVATIONS) MArqCINI I I I / I I I I I LLARCHITECTURE 10'-0" I I I / 3 METAL STUDS AT I I Q CONSTRUCTION FINISHED CEILING I I / / I 48 O.C. ATTACHED I I - M U I WITH CLIP ANGLE TO I I 00 I I I I BOTTOM OF STRUCTURE I I I I 222 Middle Country Rd, Suite 314 Smithtown, NY 11787 3 J" METAL STUDS AT I I / / I I I I z 4' HIGH SCHEDULED TILE T: 631-979-0104 _ 16" O.C. ATTACHED F: 631-979-3445 ( I / / I I I I h TO BOTTOM OF DECK FINISHED CEILING info@manciniarchitecture.com / I I I TILE BACKERS ODUROROCK z Q I I ORSUUBMIITOTED EQUAL) SUSPENDED CEILING w (1) LAYER OF J" .. GYPSUM BOARD 1— o o I 2 X BLOCKING AT ALL BAR — — — — — — — 8'-0" F- w I MOUNTING LOCATIONS I FINISHED CEILING Q I 2" RETURN: WRAP WC-1 LO TO INSIDE CORNER VP SECTION THROUGH SOFFIT @ RECEPTION PASSTHROUGH DETAIL VERTICAL GRAB BAR /WALL DETAIL 05 1„=1 ,-�„ 03 1_1 2„=1 ,_U„ 02 WALL NOTES: ROOF DECK4 7/8 @ 3 5/8 STUD 1. ALL NON—LOAD BEARING WALL STUDS TO BE 20 GA @ 16” O.C. WITH 18 GA f -I RUNNERS TOP & BOTTOM UNLESS OTHERWISE NOTED OR LIMITED BY THE This drawing has been prepared for the METAL STUD HEIGHT TABLE TABLE. SECURE 2” FROM EACH END @ 24" O.C. 3 J" METAL STUD DIAGONAL WALL TO UNDERSIDE OF ROOF indicated project and is an instrument of WITH FASTENERS REFER TO STRUCTURAL DWGS FOR LOAD BEARING STUD BRACING AT 4'-0" O.C. MAX DECK service copyrighted by Mancini Architecture REQUIREMENTS. PLLC. This drawing may not be copied or 2. ALL STUD WALLS TO BE BRACED FROM FLOOR TO ROOF STRUCTURE AT 4'-0" 4 749 " " sTUn NEW SUSPENDED CEILING — SEE used, in whole or in part, by any party without O.C. CEILING PLAN FOR HEIGHT 4 7/8 @ 3 5 8 STUD the expressed written consent of Mancini 3. STUD FRAMING TO BE PROVIDED WITH HORIZONTAL STRAP BRIDGING EVERY SOUND BAGGED INSULATION AT Architecture PLLC. Infringements or any use 4'-0" O.C. ALL EXAM & OFFICE CEILINGS (1) LAYER 5/8" TYPE X GYP. PL-2 LAMINATE TOP of this drawing for any other purposes will be 4. ALL GYPSUM BOARD IS WET AREAS TO BE MOISTURE RESISTANT TYPE. ID BOARD BOTH SIDES prosecuted to the full extend of criminal law 5. ALL GYPSUM BOARD TO HAVE 3 COATS OF JOINT COMPOUND TO BE APPLIED (1) LAYER 5/8 GYP. TO AL JOINTS AND SCREW HEADS WITH 2" PAPER TAPE EMBEDDED IN FIRST SUSPENDED CEILING BOARD BOTH SIDES ALLOUTSIDE INSULATION SOUND CORNERS OF STUD WALLS AND SOFFIT TO BE PROVIDED WITH (1) LAYER 5/8" GYP. PROOF 6. AL METAL CORNER BEADS. BOARD, BOTH SIDES 3 " MTL. STUDS, 16" O.C. KEY PLAN 7. ALL GYPSUM BOARD EDGES AGAINST MASONRY AND METAL OR WOOD FRAMES 3 J" MTL. STUDS, 16" O.C. TO BE PROVIDED WITH "S" BEADS. BATT INSULATION SOUND W/ TOP DEFLECTION TRACK N 8. ALL GWB SHALL BE INSTALLED VERTICALLY AND STAGGERED ON OPPOSITE PROOF SCHEDULED FINISH SIDES OF ASSEMBLY W/ FASTENERS. SCHEDULED FINISH 9. USE MOISTURE RESISTANT GYPSUM PANELS IN TOILET AREAS &EXTEND TO 3J" MTL. STUDS, 16" O.C. SCHEDULED BASE UNDERSIDE OF DECK SCHEDULED BASE 10. USE DUROCK CEMENT BOARD WHERE CERAMIC TILE IS SPECIFIED. COORDINATE SCHEDULED FLOOR LOCATION WITH FINISH ELEVATIONS, LEGENDS, AND SCHEDULES. SCHEDULED FLOOR 11. USE J" TYPE X GYPSUM BOARD IN ALL FIRE RATED WALLS AS SPECIFIED IN SCHEDULED FINISH WALL TYPES. SCHEDULED BASE \ I- METAL STUDS @ MA STATION - B METAL STUDS ® INTERIOR `, 1 HR FIRE RATED - UL U495 MAXIMUM NON—LOAD BEARING SCHEDULED FLOOR METAL STUD UMI'nNG HEIGHTS 7777 � 1 -M @ BATHROOM STUD SIZE 20 GA. 18 GA. s A. 5 8" TILE BACKER BOARD WONDERBOARD, 3 5/8" 016" O.C. 15'-2" 16'-7" 17'-9" A METAL STUDS ® INTERIOR / ( NEWINTERIOR WALLS DUROROCK OR SUBMITTED EQUAL) UP TO 3 5/8" ® 12" O.C. 16'-9" 18'-3" 19'-7" 48" AFF ON BATHROOM SIDE 6" 0 16" O.C. 22'-8" 24'-9" 26'-6- 6" ® 12" O.C. 25'-0" 27'-3" 29'-2" PROJECT 8" ® 16" O.C. 28'-7" 31'-2" 33'-6" 7 1/4" @ 6" STUD STONYBROOK 8" ® 12" O.C. 31'-6" 34'-4" 36'-10" WALL TO UNDERSIDE OF ROOF MEDICINE DECK 10095 MAIN ROAD NEW SUSPENDED CEILING — SEE MATTITUCK, NY 11952 CEILING PLAN FOR HEIGHT EXISTING METAL MILLWORK TOP SEE MILLWORK DRAWING TITLE STUDS (1) LAYER 5/8" GYP. BOARD REFILL WITH R-13 BOTH SIDES SECTIONS FOR MORE INFORMATION CONSTRUCTION BATT INSULATION ON BATT INSULATION SOUND 2X4 WOOD BLOCKING EXTERIOR WALLS PROOF ALONG TOP DETAILS & WALL NEW (1) LAYER 5/8" (1) LAYER I" PLY TYPES GYP. BOARD 6 MTL. STUDS, 16 O.C. W/ SHEATHING BOTH SIDES TOP DEFLECTION TRACK SCHEDULED FINISH " TILE BACKER BOARD (1) LAYER 5/8" GYP. BOARD BOTH SIDES SCALE SCALE AS SHOWN SCHEDULED BASE (WONDERBOARD, DUROROCK OR n DRAWN BY ML SUBMITTED EQUAL) UP TO 48" AFF ' SCHEDULED FLOOR N 3J" MTL. STUDS, 16" O.C. SCHEDULED FINISH (SEE FINISH DRAWN FOR -- SCHEDULE) SCHEDULED FINISH CHECKED BY MM E EXISTING WALLS SCHEDULED FLOOR SCHEDULED BASE PROJECT# -- SCHEDULED FLOOR DATE 3/9/2020 METAL STUDS @ INTERIOR F 6 " STUDS AT BATHROOM WALL G METAL STUDS @ INTERIOR SHEET NO. MILLWORK SUPPORT WALL A-500 WALL TYPES 01 — N.T.S. ---- SHEET OF NO. REVISIONS DATE 1Q ADDENDUM 1 8/12/20 DOOR AND FRAME SCHEDULE PLUMBING LEGEND Z UJLABEL SYMBOL DESCRIPTION MANUFACTURER MODEL # COLOR/FINISH NOTES Q z Q DOOR FRAME z = o ADA COMPLIANT ONE PIECE SAN SOUCI INCLUDE K-4008 REVEAL QUIET—CLOSE o- 00 COMPACT TOILET K-5172 KOHLER WHITE 0 >- w d o ¢ ELONGATED TOILET SEAT >- � Q (if N Z W � Q = NOTES ^ z Q F � o o co w xFAUCET: KOHLER WILLAMETTE o- w [L a cn 0 cn �- o' w w w F— N w LAVATORY ADA COMPLIANT BRENHAM #K—R99901-4D1 0 0- o KOHLER WHITE SIZE w > I I I I I I o o_ o a Z WALL MOUNTED SINK K-1999—SS8 V) z F- �— N N f— Q w o O z SHROUD: BRENHAM K-1998—SS MARK MAT'L EL. MAT'L EL Q w w w w w w w a' cn w W o = w # � (n V) U) U) V) V v w W _ � z c� NO. ISSUED DATE b W UJ Y Y Y Y Y Y z Ul Q J W F- WIDTH HEIGHT THICKNESS Q z z o 0 0 0 0 0 W o o a > Q w o o SINGLE COMPARTMENT 1 80% COMPLETION SET 4/16/20 2 z z J J 0 J J J t—n v w 3 o < o' 0 w STAINLESS STEEL DROP IN ELKAY LR1716SC STAINLESS STEEL SINK 2 95% COMPLETION SET 5/14/20 1 S-011 7 —0 1 WD D2 HM F1 6X24 VISION PANEL X X X X X 2 3'-0" 7'-0" 1 WD D1 HM F1 X X X X SINGLE COMPARTMENT FAUCET: MODEL #LKD232SBH55C 3 COMPLETED CONST. SET 5/22/20 3 3'-0" 7'-0" 1 WD D1 HM F1 X X X X o STAINLESS STEEL DROP IN ELKAY LRADQ202265PD2 STAINLESS STEEL AT BREAK ROOM, SOIL ROOM, AND MED 4 COMPLETED CONST. SET 6/4/20 4 3'—Cl" 7'-0" 1�" WD D1 WD F2 POCKET DOOR X SINK ROOM 5 COMPLETED CONST. SET 6/12/20 5 3'-0" 7'-0" 1 WD D1 HM F1 X X X X SURFACE MOUNTED HAND " DRYER 6 3'-0 7'-0" 1 WD D1 HM F1 X X X X EXCEL XL—BW 6 ISSUED FOR PERMIT 7/7/20 7 S-0" 7'-0" 1 WD D1 HM F1 X X X X 1-1/2" STAINLESS STEEL BOBRICK #B-6806 X 36" SATIN FINISH 8 S-0" 7'-0" 1 WD D1 HM F1 X X X X HORIZONTAL GRAB BAR , 9 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 1-1/2" STAINLESS STEEL BOBRICK #B-6806 X 42" SATIN FINISH Stony Brook Medicine 10 3'-0" HORIZONTAL GRAB BAR 7'-0 1 WD D1 HM F1 BATHROOM SIGNAGE X X X X X X 11 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 1-1/2" STAINLESS STEEL BOBRICK #13-6806 X 18" SATIN FINISH 12 3'-0l" 7'-0" 1 WD D1 HM F1 X X X X VERTICAL GRAB BAR 13 3'-0" 7'-0" 1 WD D1 HM F1 X X X X RECESSED TOILET TISSUE 14 3'—C" 7'-0" 1 WD D1 HM F1 X X X X E9 DISPENSER DOUBLE ROLL BOBRICK B-3094 15 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 16 3'—Ci" 7'-0" 1 WD D1 WD F2 POCKET DOOR X SURFACDI DISPENSER 17 SOAP BOBRICK MODEL #818615 MAFI'N' CINI 17 3'—O" 7'-0" 1 " WD D1 HM F1 X X X X ARCHITECTURE 18 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 18" X 36" MIRROR BOBRICK B-165-1836 mul CONSTRUCTION 19 3'-0" 7'-0" 1 WD D1 HM F1 X X X X 20 3'—C" 7'-0" 1 WD D1 HM F1 X X _ X X 222 Middle Country Rd, Suite 314 21 S-0" 7'-0" 1 WD D1 HM F1 BATHROOM SIGNAGE X X X X X X F_ M_ ADA COMPLIANT WATER ENHANCED EZH2O Smithtown, NY 11787 22 3'-0" 7'-0" 1 WD D1 HM F1 X X X X FOUNTAIN ELKAY # LZSTL8WSLP STAINLESS STEEL T: 631-979-0104 F: 631-979-3445 23 3'—O" 7'-0" 1�" WD D1 HM F1 X X X X KOALA KARE STAINLESS STEEL info@manciniarchitecture.com 24 3'-0" 7'-0" 1�" WD D1 HM F1 X X X X BABY CHANGING STATION PRODUCTS KB-110—SSWM WALL MOUNTED 25 3'-0" 7'-0" 1 " WD D1 HM F1 X X X X ------- 26 3'-O" 7'-0" 1�" WD D1 HM F1 X X X X PROVIDE MUSTEE MODEL 63.600A CHROME PLATED FAUCET WITH VACUUM 27 3'-C" 7'-0" 1 WD D1 HM F1 X X X X JANITOR'S UTILITY SINK MUSTEE MODEL 63M WHITE BREAKER, MUSTEE MODEL 65.700 HOSE 28 3'-8" 7'-0" 1 WD D1 HM F1 X X X X AND HOSE HOLDER, & MUSTEE MODEL 29 3'-8" 7'-0" 1 WD D2 HM F1 6"X24" VISION PANEL X X X X X 65.500 MOP AND HANGER SEE PLAN FOR DOOR DIRECTION DOOR AND FRAME ELEVATIONS DOOR NOTES: 61' 1. ALL OPERABLE HANDLES SHALL BE ANSI 117.1 2009 COMPLIANT LEVER HANDLES OR PULL HANDLES. REPLACE ALL EXISTING HARDWARE TO BE COMPLIANT. 3'-0" 3'-0" 2. EXTERIOR DOORS SHALL BE PROVIDED WITH ANSI 117.1 2009 COMPLIANT I THRESHOLDS 1). ALL PULLS, LATCHES, LOCKS, CLOSERS, AND ANY OTHER EQUIPMENT SHALL BE ANSI 117.1 2009 COMPLIANT AND COMPLY WITH BC 1008.. ADA WOMENS BATHR �M ADA MENS BAT OOM 4. CONTRACTOR SHALL PROVIDED SUBMITTALS OF ALL ITEMS FOR REVIEW AND I APPROVAL PRIOR TO INSTALLATION. SIGN (TYP) SIGN (TYP) 5. ALL FIRE RATED DOORS AND FRAMES SHALL SHALL BE UL LABELED. This drawing has been prepared for the 6. ALL HARDWARE IN FIRE RATED DOORS SHALL BE LISTED FOR USE IN ASSEMBLIES ` indicated project and is an instrument of o o service copyrighted by Mancini Architecture OF FIRE RATING LISTED IN SCHEDULE. PLLC. This drawing may not be copied or ``� I � used, in whole or in part, by any party without the expressed written consent of Mancini ` Architecture PLLC. Infringements or any use D1 D2 LEGEND: PR PAIR BRAILLE o BRAILLE o of this drawing for any other purposes will be F1 F2 AL ALUMINUM PVC PVC 1 prosecuted to the full extend of criminal law EX EXISTING SS STAINLESS STEEL FRP FIBERGLASS REINFORCED POLYESTER SSHM STAINLESS STEEL HOLLOW METAL HM HOLLOW METAL SC SOLID CORE cV N KD KNOCK-DOWN VS VINYL STRIPS I . I KEY PLAN PE POLYETHYLENE WD WOOD (BIRCH WOOD) d HARDWARE MANUFACTURERS AND SERIES: HARDWARE NOTES: HINGES: 41" MCKINNEY FULL MORTISE HINGES 1. ALL LOCKS TO BE KEYED TO BUILDING MASTER KEY. 2. ALL HARDWARE TO HAVE US26D FINISH. CONTINUOUS HINGES: MCKINNEY FULL MORTISE SAFETY HINGE 3. PROVIDE OVERHEAD STOP IN LIEU OF FLOOR STOP ON DOORS WHERE TRIPPING HAZARD LOCKSET: SARGENT 10 LINE - L LEVER EXISTING OR AS INDICATED. TYPKAL4. FOR ENTRY DOORS & FRAMES, FINISHES MAY VARY BETWEEN INSIDE AND OUTSIDE RESTROOM S DETAIL CLOSER: NORTON SERIES 8501 & 9501 SURFACES. SCHEDULED FINISHES ARE TYPICALLY FOR INTERIOR FINISHES ONLY. EXTERIOR FLOOR STOP: ROCKWOOD #440 SERIES AND OR PUBLIC CORRIDOR SIDE OF DOORS & FRAMES ARE TO MATCH OTHER EXTERIOR SCALE: 1/2"=1'-0" FINISHES OR AS SPECIFIED ELSEWHERE. OVERHEAD STOP: GLYNN—JOHNSON 90 H HOLD OPEN MODEL 5. THE CONTRACTOR SHALL PROVIDE DOOR AND BUCK ASSEMBLIES AS SPECIFIED ON SILENCERS: ROCKWOOD #608 ARCHITECTS DRAWINGS AND DETAILS. 6. ALL LOCK SETS SHALL BE CODED AND OR KEYED IN ACCORDANCE WITH THE BUILDING ELECTRIC STRIKE: RCI RUTHERFORD CONTROLS REQUIREMENTS, CODES AND OR KEYS ARE TO BE DELIVERED TO CLIENT PROPERLY TESTED MANUAL FLUSH BOLT: IVES F6358, PROVIDE AT ALL DOUBLE DOORS AND OR TAGGED. PROVIDE 3 MASTER KEYS AND 3 PASS KEYS FOR EACH LOCK. 7. ALL FIRE RATED DOORS TO HAVE FIRE RATED DOOR FRAMES TO MATCH LABEL OF WALL. PROJECT ARMOR PLATE: ROCKWOOD — METAL DOOR PLATE #K1038 8 ALL WOOD DOORSEgDrDOO VT INDUSTRIES V LATCHING HARDWARE AND CLOSER HARDWARE INSTALLED. STONYBROOK EMERGENCY RESCUE: STANLEY DOUBLE ACTING PIVOT, DOUBLE LAPPED MODEL: HERITAGE STRIKE SIZED FOR EMERGENCY RELEASE STOP, ETC. CUT/SPECIES: PREFINISHED WHITE MAPLE MEDICINE BRUSH TYPE WEATHER STRIPPING ® JAMBS AND STAIN/FINISH: #CH 18 CHOCOLATE 10095 MAIN ROAD HEAD FOR PRIVACY SIZED: PER SCHEDULE MATTITUCK, NY 11952 9. ACOUSTIC WOOD DOORS BY VT INDUSTRIES - COORDINATOR: ROCKWOOD MODELS: HERITAGE SOUND CORE STC 49 SLIDING CLOSET DOORS: STANLEY SLIDING DOOR HARDWARE, MODEL #2841 CUT/SPECIES: PREFINISHED WHITE MAPLE DRAWING TITLE STAIN/FINISH: SEE FINISH MATERIAL SCHEDULE ICU STYLE DOCR #1: HORTON AUTOMATICS TYPE 310 TRACKLESS SO-EX SIZED: PER SCHEDULE OR APPROVED EQUAL 10. FRAMES TO BE EQUAL DOUBLE RABBET, FULLY WELDED TYPE 16 GAUGE, DRYWALL SLIP ON SCHEDULES PROFILE. PROVIDE MINIMUM (2) 20 GAUGE METAL STUDS AT JAMBS. FIRE RATED FRAMES ICU STYLE DOOR #2: NORTON AUTOMATICS TYPE 110 0-SX, OR SHALL HAVE THE SAME RATING AS REQUIRED BY THE DOOR. PROVIDE 14 GAUGE APPROVED EQUAL REINFORCING FOR CLOSER AND LOCK, 7 GAUGE FOR HINGES. CORNERS TO BE MITERED. PROVIDE 4" HEAD AT MASONRY. PROVIDE 8" HEAD AT AUTOMATIC DOOR CLOSERS (ONE SIDE ONLY). JAMB ANCHORS SHALL BE PROVIDED AND APPROPRIATE FOR THE WALL TYPE AND BE MINIMUM 16 GAUGE. SCALE SCALE AS SHOWN DRAWN BY ML DRAWN FOR -- CHECKED BY MM PROJECT# -- DATE 3/9/2020 SHEET NO. A-600 ---- SHEET OF