Loading...
HomeMy WebLinkAbout45933-Z o��S�EF01,�cOG Town of Southold 5/18/2021 P.O.Box 1179 o _ 53095 Main Rd y.; �ao�;�' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42034 Date: 5/18/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 395 Beckwith Ave., Southold SCTM#: 473889 Sec/Block/Lot: 61.-1-24 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/25/2021 pursuant to which Building Permit No. 45933 dated 3/16/2021 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Alvarez,Horacio&Ada of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45933 4/1/2021 PLUMBERS CERTIFICATION DATED A tho iz d Signature o�SUFFai,�ooTOWN OF SOUTHOLD BUILDING DEPARTMENT y, TOWN CLERK'S OFFICE SOUTHOLD, NY 0 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45933 Date: 3/16/2021 Permission is hereby granted to: Alvarez, Horacio 395 Beckwith Ave Southold, NY 11971 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 395 Beckwith Ave., Southold SCTM # 473889 Sec/Block/Lot# 61.-1-24 Pursuant to application dated 2/25/2021 and approved by the Building Inspector. To expire on 9/15/2022. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO-ALTERATION TO DWELLING $50.00 4 Total: $200.00 ilding spector I Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of,electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features,, 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, ' Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 2/24/2021 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 396 BECKWITH AVE,SOUTHHOLD,NY 11971 House No. Street Hamlet Owner or Owners of Property: HORACIO ALVAREZ Suffolk County Tax Map No 1000,Section 061.00 Block 01.00 Lot 024.000 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: SUNG LEE Health Dept,Approval: Underwriters Approval: Planning Board Approval: Request for: ' Temporary Certificate Final Certificate: K(checke Fee Submitted: $ 50 Applicant Signature so�,r�®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® a� roper.richerti D_town.southold.ny.us Southold,NY 11971-0959 .� ®lac®UNT�,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Horacio Alvarez Address: 395 Beckwith Ave City: Southold St: New York Zip: 11971 Building Permit# 45933 Section: 61 Block: 1 Lot 24 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Island Electric Corp License No: ME-37608 SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment: 10.85 KW roof mounted photovoltaic system to include, 31-350 w solar panels witl 31-micro inverters,combiner box,50a AC disconnect Notes Inspector Signature: Date: April 1 2021 81-Cert Electrical Compliance Form.xls hO�apF SOUlyo6 # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 4-7 INSPECTION uk [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND ' [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE'& CHIMNEY-, [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [n ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [` ] PRE C/O REMARKS: K-14/ DATE `r L2_4 INSPECTOR * #laf so TOWN'-OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [/11FINAL SULATION/CAULKINGFRAMING/STRAPPING [ [ ] FIREPLACE &CHIMNEY- [ ' ]--FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: .01t DATE I'y�(�vc INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS • CA FOUNDATION(1ST) ----------------------------------�- t -� O FOUNDATION(2ND) ` o .SU r-� ROUGH FRAMING& y PLUMBING INSULATION PER N.Y. y STATE ENERGY CODE WWI d ' FINAL ADDITIONAL COMMENTS o �y y4iB✓ th��v O� PIKS Z L - n °z y b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 - Planning Board approval FAX: (631)765-9502 '33 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees y t _j' , -7, C.O.Application `:� ,,: ', Flood Permit Examined ,20 I-• ; �, .�� Single&Separate 42 5 2�2� Truss Identification Form FEB Storm-Water Assessment Form v, Contact: Approved20 h'w r`"r '+ .,. ; " +, Mail to: Disapprov*a/c Phone: Expiration ,20 Buil g or APPLICATION FOR BUILDING PERMIT021q Date �6'✓ , 20 J INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of fhe permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as he in described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and re gu t ns,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applican r name,if a corporation) 45 Fairchild Ave. Suite B. Plainview, NY 11803 (Mailing address of applicant) State whether applicant is owner,lessee, agent, architect, engineer,general contractor, electrician,plumber or builder Cnntrantnr Name of owner of premises HORACIO ALVAREZ (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 37608-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 396 BECKWITH AVE,SOUTHHOLD,NY 11971 House Number Street Hamlet County Tax Map No. 1000 Section 061.00 Block 01.00 Lot 024.000 L Subdivision Filed Map No. Lot +2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy 1-family b. Intended use and occupancy 1-family 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work solar panel installation (Description) 4. Estimated Cost $34,828.5 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. if business,commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dunensions of existing structures, if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO x 13. Will lot be re-graded?YES NO x Will excess fill be removed from premises?YES NO x 14.Names of Owner of premises HORACIO ALVAREZ Address 396 BECKWITH AVE Phone No. 6316648696 Name of Architect Samuel Dekyem Address3096 HAMILTON BLVD Phone No (732)902-6224 Name of Contractor Sung Lee Address 45 Fairchild Ave Phone No. 516 218 5824 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO x * IF YES, SOUTHOLD TOWN TRUSTEES&D.E.C. PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland? *YES NO x * IF YES, D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? *YES NO x *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) Sung Lee being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 24th day r' 20 21 e�5b�c e �o�` e� o& �5 aCo je 3,Zo2� Notary Publico� eg•�a�oNa OeSignature of Applicant CAS BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD 'U® Town Hall Annex - 54375 Main Road - PO Box 1179 ,r,� Southold, New York 11971-0959 ' ®• xy Telephone (631) 765-1802 - FAX (631) 765-9502 roaerrO-southoldtownnv gov— sea ndtc7i southoldtownny gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date. 2/24/2021 Company Name: ISLAND ELECTRIC CORP Name: JEFFREY MARINELLO License No.: ME-37608 email: permitsli@momentumsolar.com Address: 76 KERRIGAN ST LONG BEACH NY 11561 Phone No.: 516 903 2008 JOB SITE INFORMATION (All Information Required) Name: HORACIO ALVAREZ Address: 396 BECKWITH AVE SOUTHHOLD,NY 11971 Cross.Street: �• Phone No.: 6316648696 Bldg.Permit#: email: alverezhoracio11223@gmail.com ; Tax Map District: 1000 Section: 061.00 Block: 01.00 Lot: 024.000 BRIEF DESCRIPTION OF WORK (Please Print Clearly) 71- INSTALLATION INSTALLATION OF SOLAR PANELS;ROOF TOP, GRID TIED, RAIL LESS; 10.85 KW 31 MODULES Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES /e Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect-Service Reconnected- Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form.xis Suffolk County Dep' t. of = I Labors Licensin g & Consumer Affairs GGA MASTER_ ELECTRICAL LICENSE Name- JEFFREY MARINELLO Business Name ISLAND ELECTRIC CORP This certifies that the bearer is duly licensed License N d m be r ME-37608 b the Coon of �$ y ty Suffolk Issued : 05124/2005 Commissioner Expires : 0' 4112021 h v Suffolk County-Dept. of Labor, -Licensing & Consumer Affairs- - HOME IMPROVEMENT LICENSE Dame Sly NG ' LEE Business Dame This ci rtifes tPnat the t bearer is ,duly licensed PFO CUSTOM SOLAR,LLC .DEA ea Y by the" County of•suffolk _ W License Dumber: H-57578 Rosette Dr',-ago Issued: 10/06/2016 Commissioner Expires: 10/01 /2022 f Ii,hl t Yworkers' CERTIFICATE OF INSURANCE COVERAGE ware CompS'LAW ensation i Board DISABILITY AND PAID FAMILY LEAVE BENEFIT !j,; !1 PART 1.To 6e completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier g 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured ? PRO CUSTOM SOLAR LLC (732)902-6224 DBA MOMENTUM SOLAR 3096 HAMILTON BOULEVARD SOUTH PLAINFIELD,NJ 07080 ; • ,I ri;l•• i 1c.Federal Employer Identification Number of Insured or Social Security, Work Location of Insured(Only required if coverage is specifically limited to Number p certain locations in New York State,i.e.,a Wrap-Up I P P Polic Yl 271242539 l�i'I 2.Name and Address,of Entity Requesting Proof,of Coverage 3a.Name'of Insurance Carrier (Entity Being,Listed,as the-Certificate Holder), New York State Insurance Fund(NYSIF) I i TOWN OF SOUTH& 54375 ROUTE 25 3b.Policy Number of Entity Listed in Box"la" i a SOUTHOLD,NY 119711 DBL 315268-4 3c.Policy effective period 07/01/2020 to 07/01/2021 I i 4.Policy provides the following benefits: it ® A.Both'disability and paid family leave benefits .• B.Disability,benefiits only C.Paid family leave benefits only IIf 5.Policy covers:, _ I III ® A.AII'of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law ❑ B.Only the following class or classes of employer's employees: I Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named'' 'G insured has NYS Disability,'and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 7/3/2020 By, (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that Insurance carrier) y ', Telephone Number (866)697-4332 Name and Title Melissa Jensen,Director of Disability Insurance Unit IMPORTANT: If Box 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS !' Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. (; " If,Box 413,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers',Compensation Board, 013 Plans Acceptance Unit,,PO Box 5200,Binghamton, NY 13902-5200 r PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4C or 56 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. l • I� Date Signed By, f (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title j ! iI i„ Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance'agents' of those insurance carriers are:authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to Issue this form. DB-120.1 (10-11) Certificate Number 603429 ;I- 1; t A_CORD® (MMIDD/YYYY) CERTIFICATE OF LIABILITY INSURANCE DATE1z/o1/2020 , THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLYAND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER, IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME:CT Lisa MacDonald AAI CISR C Brown&Brown Insurance of Delaware Valley PHONE (732)504-2001 FAX (732)504-2011 2000 Midlantic Dr,Suite 440 E-MAIL ° alc No ADDRESS. Imacdonald@bbdvins.com INSURER(S)AFFORDING COVERAGE NAIC# Mt Laurel NJ 08054 INSURER A: Colony Insurance Company INSUREDINSURER B: Zurich American Insurance Company 16535,1 Pro Custom Solar LLC dba Momentum Solar INSURER C: Evanston Insurance Company ' Momentum Home Services Holding LLC dba Momentum Home INSURER D 45 Fairchild Ave,Suite B INSURER E: Plainview• , NY 11803 INSURER F: j COVERAGES CERTIFICATE NUMBER: 20-21 NY Master REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD i INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MMlDD MIDD LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE FX]OCCUR DAMAGE T RENTED100,000 PREMISES Ea occurrence $ MED EXP(Any one person) $ 5,000 ' A PACES4257993 04/21/2020 04/21/2021 PERSONAL&ADV INJURY $ 1,000,000 .i GEN'LAGGREGATE LIMITAPPLIES PER GENERAL AGGREGATE $ 2,000,000 POLICY 0 � PRODUCTS-COMP/OPAGG $E2.000,000 OTHER: Professional Liability $ 1,000,000' AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 2,000,000 Ea accident X ANYAUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED 'BAP 1873088-01 12/01/2020 04/21/2021 AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ X HIRED NON-OWNED AUTOS ONLY X AUTOS ONLY PROPERTY DAMAGE $ Per accident UMBRELLALIAB X OCCUR 5,000,000 I EACH OCCURRENCE $ C X EXCESSLWB CLAIMS-MADE MKLV4EFX102168 04/21/2020 04/21/2021 AGGREGATE $ 5,000,000 DED RETENTION$ $ WORKERS COMPENSATION I PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EX-11— OFFICER/MEMBER EXCLUDED? LiN/A EL EACH ACCIDENT $ (Mandatory in FEL DISEASE-EA EMPLOYEE $ If yes,describe ander und , DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Excess Limits Clarification CGL$5M xs$1 M ' C MKLV4EFX102168 04/21/2020 04/21/2021 Auto$4M xs$2M DESCRIPTION OF OPERATIONS!LOCATIONS!VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) 4 � CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN ' Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Middle Road AUTHORIZED REPRESENTATIVE Southold NY 11971 ©1988-2015 ACORD CORPORATION. All rights reserved. , ik ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Ik <SYTORK Workers' CERTIFICATE OF ATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board • 1a.Legal Name Address of Insured(use street address only) 1b.Business Telephone Number of Insured CoAdvantage Resources 51,Inc.Labor Contractor,for leased workers to: (813) 935-2000 Pro Custom Solar,LLC dba:Momentum Solar 1c.NYS Unemployment Insurance Employer Registration Number of insured 45 Fairchild Ave Ste B Plainview,NY 11803 Work Location of Insured(Only required if coverage is specifically limited to certain 1 d.Federal Employer Identification Number of Insured or Social SecurityNumber locations in New York State,i.e.,a Wrap-Up Policy) 27-1242539 2.Name and Address of Entity Requesting Proof of Coverage(Entity Being 3a.Name of Insurance Carrier Listed as the Certificate Holder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1 all 53095 Middle Road WC 11-25-632-02 3c.Policy effective period Southold, NY' 1.1971 . 4/1/2020 to 4/1/2021 3d.The Proprietor,Partners,or Executive Officers are included.(Only check box if all partners/officers inclued) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3 insures the business r ferenced above in box"la"for workers'compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2" The insurance carrier must notify the above certificate holder and the Workers Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box 3c,whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this forth,if the business continues to be named on a permit,licese or contract issued by a certificate holder,teh business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the,mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance cancer refemced above and that the,named insured has the coverage as depicted on this form. Approved by: Douglas Jones (Print name of authorized representative or licensed agent of insurance carrier) Approved bv: C��„ Z'�✓ 3/30/2020 (Signature) (Date) Title: Vice President Telephone number of authorized representative or licensed agent of insurance carrier (480)951-4177 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17) ww.vvcb.ny.gov' ' e Samuel Dekyem _ - =_ _ Engineer-PE - _ - - = - Samuel Dekyem - _ - - Engineer-PE Pro Custom Solar LLC 732-902-6224 Pro Custom Solar LLC 732-902-6224 3096B Hamilton Blvd January 29,2021 3096B Hamilton Blvd January 29,2021 South Plainfield,NJ 07080 South Plainfield,NJ 07080 Re:Proposed Photovoltaic Solar Panel Installation Gravity Load Calculation Criteria Horacio Alvarez _ Structural Design Loads per ASCE 7_-16 - = A 396 BECKWITH AVE APPROVED AS NOTED SOUTHHOLD,NY 11971 Dead Loads=10 psf+2.6-psf-(new solar panels)=12 6 psf- - Roof Live Load=20 psf DATE: B.P.# .3 Dear Plan Reviewer: Ground Snow Load/Live Load=25 psf FEE: ii BY: Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this projectNOTIFY BUILDING DEPARTMENT AT and I certify that the products are capable of supporting the code required loads and are suitable for this installation Wind Load Calculation Criteria when installed in strict compliance with the manufacturers printed instructions. Wind Loads per ASCE 7-16,Ch.30.4 765-1802 ' 8 AM TO 4 PM FOR THE Design wind pressure determined by Eq.29.4-7: FOLLOWING INSPECTIONS: Regarding the solar panel array installation on the above referenced project please note that an inspection was 1. FOUNDATION - TWO REQUIRED performed by a representative of the Architect/Engineer of Record,and analysis of the existing structure was Zone 1=-23.6 psf Roof Slope=34 degrees Roof Mean Height=15 ft conducted.There is adequate structural capacity for the installation of the array with the following recommendations: Zone 2=-30.7 psf Basic Wind Speed=130 mph FOR POURED CONCRETE Zone 3=-34.6 psf Exposure=B 2. ROUGH - FRAMING & PLUMBING 1.The array will be installed on the existing roof.The roof framing is constmcted of 2"x8"wood rafters @24"o.c. 3. INSULATION spanning 9'8"with 1/2"plywood sheathing.The new array(See Site map by contractor)will add 2.63 Lb./Sf.overall to the roof.No additional structural support is required for the roof structure. Per section 2.4.1,ASD combo=D+0.6W: 4. FINAL - CONSTRUCTION MUST Zone 1=2.6psf+0.6(-23.6 psf)=-11.6 psf BE COMPLETE FOR -',.0• Zone 2=2.6 psf+0.6(-30.7 psf)=-15.8 psf ALL CONSTRUCTION SHALL MEET THE 2.The attachment system shall be secured to the roof and shall be in strict compliance with manufacturers printed Zone 3=2.6 psf+0.6(-34.6 psf)=-18.2 psf REQUIREMENTS OF THE CODES OF NEW instructions.The attachment system shall be UL 1703 approved tested.Provide 6 mil.vapor barrier between YORK STATE. NOT RESPONSIBLE FOR dissimilar metals.Provide water tight gasket and sealant at all penetrations. Attachments shall follow panel rows as Check Attachment to Wood Rafter DESIGN OR CONSTRUCTION ERRORS. specified by the system manufacturer's installation manual.The panel angle shall match the roof slope.Reference Use 5/16 dia.Lag screw w/3"embedment into 2 in.wide roof rafter summary table below: Lag Screw Spacing: _ Lag Screw Tributary Area: Roof Type: Shingle Fastener Max Spacing(in.) Zone 1= 48"o.c.max Zone 1=(48"o.c.max)A2/144=16 SF Attachment System: "ROMECH"®"RT'Attachment Systems Wind zone I Wind zone 2 Wmd Zone 3 Zone 2= 32"o.c.max Zone 2=(32"o.c.max)A2/144=7.11 SF Fastener Info: min 5/16"x 4"long stainless-steel lags with a min. 48 32 32 Zone 3= 32"o.c.max Zone 3=(32"o.c.max)A2/144=7.11 SF embedment of 3"into the rafters 3 Solar Modules shall be UL-1703 rated.Refer to manufacturers specifications sheets. Lag Screw Forces: W=266lb/in(Table 12.2A,2015 NDS) 4.Positive drainage of the system shall be so as not to void the existing roof warranty. Zone 1=11.6 psf x 16 SF=186 lb < W', OK Cd=1.6(Table 2.3.2,2015 NDS) 5.All aspects of the installation shall comply with the 2020 Residential Code of New York State,ASCE-7-16,2017 Zone 2=15.8 psf x 7.11 SF=112 lb < W19 OK Ct=1(Table 2.3.3,2015 NDS) National Electric Code,All Local Governing County and Municipal Ordinances adopted by reference or enacted by Zone 3=18.2 psf x 7.11 SF=129 lb < W, OK W=W x embed x Cd x Ct law. W'=266 lb/m x 3 in.x 1.6 x 1=1276.8 lb 6.Please refer to the attached structural calculations. If you have any questions relating to this matter,please contact me at your earliest convenience.Thank you. Digitally signed by COMPLY WITH ALL CODES OF oF NEwr Samuel Dekyem NEW YORK STATE & TOWN CODES OCCUPANCY OR r_L°FKyc.0 DN:cn=Samuel AS REQUIRED AND CONDITIONS OF * 5 * Dekyem,o=Momentum USE IS UNLAWFUL Samuel De a P.E. n { w Solar,ou=Engineering, SOIQHOIDZOWN ZEA rri n = email=sdekyem@mome !(� NY.Lic.No.093431 �Fa 09343 � ntumhome.com,c=US SG9ReL -TGW4Z 1NGBOARD WITHOUT CERTIRIC"A ARO�essioNP� " Date::1437-05'0 ' H96LO 1VtfN4MTEES OF OCCUPANCY • - - 07:14:37-05'00' __ - � N. . . = _ ELECTRICAL WSPECVON REOUDRED PLAN KEY SYSTEM INFORMATION THE RESPONSIBLE LICENSED DESIGN PROFESSIONAL SHALL PROVIDE A SIGNED AND SEALED LETTER CERTIFYING THE mOmel��Um PV-1 COVER PAGE MODULE LG LG 350N1C-V5 INSTALLATION WAS INSPECTED AND CONFORMS TO THE PLANS AND REQUIREMENTS OF THE 2020 NYS BUILDING PV-1(2)- "COVER PAGE CONT.- INVERTER ENPHASE IQ7PLUS-72-2-US CODE AND 2020 NYS RESIDENTIAL CODE, THIS INSPECTION - SOLAR PV-2 PANEL LAYOUT RACKING_ : ROOFTECH RT-APEX AND CERTIFICATION LETTER SHALL BE PERFORMED AFTER - INSTALLATIONS ARE COMPLETED AND SHALL BE_SUBMLTTED PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR . PV-3 ELECTRICAL - TO THE BUILDING DEPARTMENT PRIOR TO SCHEDULING OF 3096 HAMILTON.BLVD:BUILDING B,S.PLAINFIELD,NJ _ - -SYSTEM SIZE (DC) -_ 10.$5 KW - _ - - - (732)902--6224,MOMENTUMSOLAR.COM_ - PV-4 EQUIPMENT LABELS _ - FINAL INSPECTION. STRUCTURAL ENGINEERING LOCATION 41.0643412,-72.4278914 _ THE UL CERTIFICATE OF ELECTRICAL INSPECTIONS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT PRIOR TO OF NES GENERAL NOTES: SCHEDULING OF FINAL INSPECTION. �Q'��vEL DF�y�O,A _THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 2020 NYS BUILDING CODE AND 2020 NYS-RESIDENTIAL CODE,-NEC=2017 AND ALL LOCAL-CODES & ORDINANCES. n W - , Z AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ON BOTH SIDES OF 2tf� THE ROOF. NOT FEWER THAN TWO PATHWAYS, ON SEPARATE ROOF PLANES FROM , LOWEST ROOF EDGE TO RIDGE AND NOT LESS THAN 36 INCHES (914 MM) WIDE, �6100 09343\ SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE Rp�ESS1pNP� PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 INCHES WIDE (914 MM) SHALL BE PROVIDED FROM THE LOWEST ROOF EDGE TO RIDGE ON THE SAME SAMUEL DEKYEM,P.E.NY LICENSE# 9 431 73z 902- 224. 3096B HAMILTON BLVDSOUTH PLAINFIELD,NJ 07060 ROOF PLANE AS THE PHOTOVOLTAIC ARRAY; ON AN ADJACENT ROOF PLANE, OR ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD TION STRADDLING THE SAME AND ADJACENT ROOF PLANES. ATTACHMENTS CALCULATIONS o EET LOCAL AND STATE BUILDING CODES& COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. CUSTOMER WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR INFORMATION PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER BILL OF MATERIALS HORACIO ALVAREZ=MS69988 SYSTEMS. NON SH MODULES 0 396 BECKWITH AVE ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT SH MODULES 31 SOUTHHOLD,NY 119716316648696 INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A INVERTERS 31 PLUMBING PERMIT AND INSPECTION. JURISTICTION:SUFFOLK INVERTER PLACEMENT: ROOFTECH BASE 103 UTILITY:PSEGLI MID CLAMP 48 UTILITY ACCT#: UTILITY METER#: SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL END CLAMP 48 LOCATED ON THE BACK SIDE OF EACH MODULE. END SPLICE 7 PV SYSTEM BUILDING REVIEW NOTE:- END FLOATING SPLICE 0 INFORMATION TOWN BUILDING PLANS EXAMINER-HAS RECEIVED THE ENCLOSED DOCUMENT FOR* MID FLOATING SPLICE 17 SYSTEM SIZE(DC): 10.85 KW SYSTEM SIZE(AC):9.145 KVA- MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED SKIRTS 14 31 MODULES:LG LG 350N1C-V5 - IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT - -ENPHASE COMBINER BOX 1 (SAFE HARBOR MODULES_31) RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW 1 INVERTERS: ENPHASE IQ7PLUS-72-2-US YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE SOLAR AC DISCONNECT 1 HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S 50A OCPD 1 PROJECT INFORMATION - - BELIEFAND INFORMATION,THE_WORK IN DOCUMENT IS: _ - - INITIAL DATE:1/28/2021 DESIGNER:SP - = 125A LINE TAPS 2 T -T 1. ACCURATE - - - - _ _ _ REV: DATE: - DESIGNER: 2. CONFORMS WITH GOVERNING_ CODES APPLICABLE AT THE TIME OF THE _REV: DATE: = DESIGNER: SUBMISSION. 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO COVER PAGE THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE RESPONSIBILITY OF THE LICENSEE. PV- i 1. ALL WIND DESIGN CRITERIA ARE FOR LOW SLOPE ROOFS,GABLE AND HIP ROOFS CONSIDERED FROM AN ANGLE OF MIN.9.5°(12)TO MAX.45°(1)NOT TO EXCEEDRTLAmomentum 30'MEAN ROOF HEIGHT ATTACHED WITH FASTENERS AS SPECIFIED BY THEPEX °" 'for rail ° ,_MANUFACTURER. - - - _ _ Installation - Item&Part Number SOLAR 2. SPAN TABLES-ARE DERIVED FROM MECHANICAL LOAD TESTS PERFORMED BY THE ° ® ° ° ° ° Install Baseand Endclamp -Slideln Mounting RT-APEX Base(RT3-00-AXBK) MANUFACTURERS INDEPENDENT TESTING AGENCIES_ ON BEHALF OF THE0 MANUFACTURER. '4% w -♦ PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR - 1-_ %of Y +1 3096 HAMILTON BLVD.BUILDING B,&PLAINFIELD,NJ 3. ROOF-SEALANTS SHALLCONFORM TO ASTMC920 AND ASTM 6511 :'` °" ; _ - «- r' RT-Apexease 24 ea (732)902-6224,MOMENTUMSOLAR.COM.- - ��` — _— STRUCTURAL ENGINEERING 4. ALL ATTACHMENTS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH _ .i : �_ _ '�`` _�_ _ sos lRT-B Bu48 tyl, MANUFACTURERS PRINTED INSTRUCTIONS. k''' _I i`3�= Middle clamp AdtlrtonCRT-Butyl2_UM_ �� .i .,��ai�t...=,,,�...=yyya "�--_ �� � Middle Clamp(RT3-02-UM-BK) [ Middle Floating Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3.02-UMSBK) pF N E vEL DF O Meddle clamp,12 ea End Clamp(RTE-g2-UE-BK)- - �* EX - - - End Floating SpUm(RT3-02-UEFSBK) A *' End Clamp Spike(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp I_ _ W Lu - End Clamp;12 ea RT-APEX Skirt(RT343-SKSOBL) Z(P c rA Universal Clamping /Slide In Mounting F6A09343 One Step Leveling / Integrated Flexible Flashing One step leveling I ROFESSIONP� 4 1/4 RT-Apex Skirt 80inch,8 ea Proven PV mounting since 1994 3" (108mm) Matenal Dela,tion ATTACHMENT SPACING EXCEED MANUFACTURERS SPECIFICATIONS FOR WIND LOADS Lq, (75mm) Base SAMUEL DEKYEM,P.E,NY CENSE#09343 732-902- 224 �� IC C� "� - clamps Anodized aluminum AS PER ASCE 07-16. RISK CATEGORY II TOPOGRAPHIC EFFECTS B,C,&D AND ROOF (` v �4 Skirt ENGIN HAMILTON TER ATTACHED PDHAS SLD,NF o�oso e us ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND �y _ Hardware Stainless steel AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& WIND ZONES 1,2,&3. ROOF ZONES 2&3 ARE WITHIN 48"OF ANY OUTER EDGE, HIP, ICC ESR 3575 Intertek _O _O- Fleluble Flashing RT Butyl OCC ESR 3575) AND LOA CALCULATIONS NTS TO MEET LOCAL AND STATE BUILDING CODE r n -- y 25 Year Umded Warranty RIDGE, OR GUTTER LINE FOR STRUCTURES 30-0 OR LESS MEAN ROOF HEIGHT. - '�� PATPENDING COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE TAW FOR 3 1/2" 90mm ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A - LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY GUTTER GUTTER • ® • •• Roof •° ••Tech Inc =� Www.roof-tech.us info@ roof-tech.us 10620 Treenj St.Suite 230,San Diego,CA,'92131 ® T (1) ® w CUSTOMER ��Q ® INFORMATION © 2 ® RIDGE RIDGE ® ® HORACIO ALVAREZ-MS69988 ® ® ®y ® 396 I SOUTHHOLD, NY 1 971 ® © O 6316648696 JURISTICTION:SUFFOLK ® O GUTTER ® GUTTER © UTILITY:PSEGLI STRUCTURAL STATEMENT: UTILITY ACCT#: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE UTILITY METER#: ROOF WIND ZONES AS PER IRC R301.2(7) NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEIV PV SYSTEM ROOF ZONES 2&3 ARE 48"FROM OUTTER ROOF EDGES, INCLUDING UPLIFT&SHEAR.EXISTING RAFTER SIZES & RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES DIMENSIONS CONFIRM TO 2020 NYS BUILDING CODE AND INFORMATION BELOW 30'-0"MEAN ROOF HT. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESIDENTIAL CODE TABLE R802.5(1)-RAFTER SPANS. SYSTEM SIZE(DC): 10.85 KW TABLE R301.2(1) MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED NEW SYSTEM SIZE(AC):9.145 KVA YORK STATE CODE REQUIREMENTS FOR THE DESIGN CRITERIA31 MODULES:LG LG 350N1C-V5 GROUND SNOW LOAD(LBS/SF) 25 OF THE TOWN. (SAFE HARBOR MODULES:31) SPEED (MPH) 130 31 INVERTERS: ENPHASE IQ7PLUS-72-2-US _ TOPOGRAPHIC EFFECTS _ B PRO7ECTINFORMATION TOTAL WEIGHT OF PV MODULES AND RAILS 1297.35 LBS SPECIAL WIND REGION NO INITIAL DATE.1/28/2021 DESIGNER:SP TOTAL NUMBER OF ATTACHMENT POINTS 96=- _ = WIND-BORNE DEBRIS ZONE 2_ - REV:- - DATE: DESIGNER: EIGHT PER ATTACHMENT_P_OINT____.___ __ 13.51.40625 LBS SEISMIC DESIGN CATEGORY C LG LG 350N1C-V5 REV: DATE: DESIGNER: - 350 WATT MODULE- OTAL SURFACE AREA OF PV MODULES 562.34 SQFT CLIMATE ZONE 4A 66.4" X 40" X 1.57" COVER PAGE ISTRIBUTED WEIGHT OF PV MODULE ON ROOF 2.31 LBS./SQFT WIND EXPOSURE CATEGORY B (SEE DATASHEET) PV- 1 ( 2) brAN SCALE: 1/8" = 1'-0" ROOF MODULE COUNT TILT AZIMUTH SHADING WAr rAN ROOF AREA 12 3 ROOF AREA 1 2 R1 9 34° 150° 85% 63/63/63 37/37/37 R2 13 35° 240° 84% 63/63/63 37/37/37 momentum " R3- 9 35° 330° 92% 63/63763 37-/37 131' -S®LAR - DRIVEWAY _ _ - - _ PRO CUSTOM SOLAR LLC D.B.A.-MOMENTUM SOLAR _ Q _ 3096 HAMILTON BLVD.BUILDING B,&PLAINFIELD,NJ - (732J902-6224,MOMENTUMSOLAR.COM' -: STRUCTURAL ENGINEERING 4 ELECTRICAL EQUIPMENT Q CB DI C AC O EXTERIOR OV NEF \ MSP INTERIOR 'P��EL DFO,A� 4 Q 4zi x w Q Q a Q < Lu 4 2 ` Q D a z Q N�4A 09343'1 4 -I Q �] ° �PESSIoNP LD "' (n SAMUEL D E , 4 4 Q3096B HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 Q ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND Q Q Ill M AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& Q - z ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE Q 6'-32" 2'-2" Q Q n COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR TTl ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A GUTTER LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. II � III ��r�� � 1 �JI , 4 Q \\ CUSTOMER r6316648696 INFORMATION HORACIO ALVAREZ-MS69988 GROUND ACCESS 396 BECKWITH AVE ACCESS ROOF SOUTHHOLD, NY 11971 3 SYMBOL LEGEND 1URISTICTION:SUFFOLK UTILITY: PSEGLI MSP MAIN SERVICE PANEL ® CHIMNEY UTILITY ACCT#: k W WW UTILITY METER#: C9 C7I�h �� ��- - —� � —� � SUB-PANEL z SKYLIGHT FIRE SETBACK SP PV SYSTEM (18" VENTILATION) �• — R2 ! O UTILITY METER ® VENT INFORMATION (TYP) KW 0'-102 RL I ' /� COMBINER BOX/AC i \ PIPE VENT (AC):SYSTEM SIZE SYSTEM SIZE(DC) ) 9.0.85 A 145 K / ` CB AC - 1 I DISC DISCONNECT / I t I I\ 31 MODULES: LG LG 350N1C-V5 d UDC UTILITY DISCONNECT FAN (SAFE HARBOR MODULES:31) 31 INVERTERS:ENPHASE IQ7PLUS-72-2 US LOAD CENTER SATELLITE DISH iii I �9 h - - R B X W/-ENVOY-S - _® FIRE SETBACKS _ _ __ TE:1/28/2021- DESIGNER:SP -- -- _ N3R NEMA 3 O INITIAL DA — y REV DATE DESIGNER COMBINER BOX GROUND ACCESS REV: DATE: - ------ DESIGNER;------ r yy 1 9 I 1 I_i- I - GUTTER PF PERFORMANCE METER —+ PITCH DIRECTION PANEL LAYOUT 31-11" MODULE PV-2 31 LG LG 350N1C-V5 350W MODULES PAIRED WITH • momentum 31 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS - SOLAR BRANCH CIRCUIT EXISTING SQUARE D 100A 9 MICRO-INVERTERS BRANCH CIRCUIT B MAIN SERVICE PANEL 240 V B PRO CUSTOM SOLAR LD.I.A.MOMENTUM SOLAR_ - - 13 MICRO-INVERTERS : - - _ _ _ - - 3096 HAMILTON-BLVD. BU.BUILDING B,S.PLAINFIELD,NJ 2 BRANCH-CIRCUITC = MAIN BREAKER:100A 9MICRO-INVERTERS a Itl Hui ENPHASE SOA AC INE SIDE STRUCTURALENGINEERING COMBINER BOX HOT TAP W/ENVOY IQ QF NE W ■ ■ ■ _ 89L AC DISCONNECT 100A �P��v�t' D�f0 SQUARE-D SOLAR AC _ GRID G, Q' DISCONNECT yt r- pE 8 - 50AI I I W J � ROOF 7.C. BREAKER 2 POWER UTILITY JUNCTIONMMUNICATION) 50A OCPD -GROUND METER �� �9343� TERMINATION CAP BOX REAKER(A)(PV) ,p 2A-C 20A BREAKER(B)(PV) 3 4 9�FESSI�NP� INSTALLED ON 20A BREAKER(C)(PV) END OF CABLE - - SAMUEL DEKYEM,P. .NY LICENSE#0934TfT7-32)-902-6224 3096B HAMILTON BLVDSOUTH PLAINFIELD,N]07080 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 10.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C)(3).AC VOLTAGE AND SYSTEM OPERATING ELECTRICIAN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. PRO CUSTOM SOLAR DBA MOMENTUM SOLAR IEEY LLO,(732)902-6224 ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 3096 HAMILTON BLVD BUILDING B,SOUTH PLAINFIELD,NJ 07080 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8. GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CUSTOMER PARAGRAPH C). THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC INFORMATION 3. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST 9. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC MODULES SHALL COMPLY WITH 250.64. BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS WILL HAVE LOWER CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS HORACIO ALVAREZ-MS69988 DESIGN CURRENT THAN THE ONE SHOWN. BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6, 690.17. 396 BECKWITH AVE 4. THIS SYSTEM COMPLIES WITH NEC 2017 DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH SOUTHHOLD, NY 11971 89L LESS THAN 10FT TO THE MAIN BREAKER/METER. 705.12(A)OR 705.12(8)AS PERMITTED BY 230.82(6) 6316648696 JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#: UTILITY METER#: PV SYSTEM INFORMATION Wire Temp. Wire Temp. Conduit - Derated Inverter NEC Design Ground Ground Wire SYSTEM SIZE(DC): 10.85 KW Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type SYSTEM SIZE(AC):9.145 KVA 1 MODULES: LG LG 350N1C-V5 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable SAFE HARBOR MODULES:31) 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 9 1.21 1.25 13.61 08 AWG THWN-2 31 INVERTERS: ENPHASE IQ7PLUS-72-2-US 213 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1.21 1.25 19.66 08 AWG THWN-2 PROJECT INFORMATION 2C 1" P-VC- - - -2 - 10 AWG - -THWN-2 90°C 40 0.96 0.8 - 30.72 9 1.21 1.25 13.61 08 AWG THWN-2 INITIAL DATE:1/28/2021. DESIGNER:SP --- -"-- - _ _ _ REV. DATE. DESIGNER• - 3 1" PVC _3 06 AWG__. THWN-2 75 C 65 0.96 1 62.40 31 1.21 1.25 46.89 = 08 AWG THWN-2 REV: DATE: DESIGNER: 4 1"PVC 3 06 AWG THWN-2 75°C 65 0.96 1 62.40 31 1.21 1.25 46.89 08 AWG THWN-2 ELECTRICAL PV-3 'h�a .- vsvhw ­A.T V1. NV I& cnriMT'LCJ 1 AT EVERY SEPARATION BY J • 12 AC CONDUITS ENCLOSURES/WALLS/ PARTITIONS/CEILINGS/FLOORS � � Yf `' OR NO MORE THAN 10' r��trc yy`: � �zea;, �" momentum ® ® • • • 3 X (:h SOLAR ®®• ®® - 1 COMBINER BOX - 1 AT ANY COMBINER-BOX - K 3 � _�-- , ., :�. � ry•, .•,� - 1 • PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR- F "'' _ F, •_ 3096 HAMILTON BLVD.BUILDING B,S.PLAINFIELD,N] ® • ®® ® _ - _ - _ - - %, � �"a y y� zr r i _ _ (732)902-6224,MOMENTUMS-OLAR.COM STRUCTURAL ENGINEERING AWARNING 4? r:{_ OF Ne C ELECTRICAL SHOCK HAZARD ffli � vSL DFk y0 TERMINALS ON BOTH LINE AND -1 __ JUNCTION BOX _1 AT ANY JUNCTION BOX = O _ CO LOAD SIDES MAY BE ENERGIZED` IN THE OPEN POSITIONcc i r W ® • - - - - - - - 1 LU - AWARN I NG ® _ D09343 00 ELECTRICAL SHOCK HAZARD v • •' ®' ® ® TERMINALS ON BOTH LINE AND m _ - - E = -_ 0pES SlO� LOAD SIDES MAY BE ENERGIZED -- —_= IN THE OPEN POSITION SAMUEL DEc s 9 i 1 OF EACH AT FUSED AC 30968 HAMILTON BLVDSOUTH PLAINFIELD,NJ 07080 ® DISCONNECT I# i' f ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND } AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& 1 AC DISCONNECT COMPLETE VOLTAGE AND ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE CURRENT VALUES ON �"' .�• - - COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR •® • ® " y _ - ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFA DISCONNECT LABEL n `j, _ LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. I ® ®® C O CUSTOMER ED • ` 1 PV METER 1 AT PV METER SOCKET AND n � INFORMATION SOCKET ONE DIRECTORY PLACARD ; - HORACIO ALVAREZ-M569988 AWARNING396 BECKWITH AVE ligij§ i' ' I Yds. SOUTHHOLD,NY 11971 �- ' �;`i • •- � DUAL POWER SOURCE 1 UTILITY METER - .,�s,�` �) SECOND SOURCE IS 1 R UTILITY METER AND ONE 6316648696 I ,Yang JURISTICTION:SUFFOLK PHOTOVOLTAIC SYSTEM DIRECTORY PLACARD \\ UTILITY:PSEGLI UTILITY ACCT#: SOLAR PV SYSTEM EQUIPPED UTILITY METER#:®WARNING _ WITH RAPID SHUTDOWN PV SYSTEM TURN RAPID SHUTDOWN 1 INTERCONNECTION SWROTOTHDUAL POWER SOURCE POINT INFORMATION PO MON TO SHUTDOUMOWN � SHOCK a�o�y SECOND SOURCE IS � SYSTEM SIZE DC): 10.85 KW J PHOTOVOLTAIC SYSTEM - - �� - ( - G SYSTEM SIZE(Ac):9.145 KVA 1 T EACH AT BUILDING �"� (� - INTERCONNECTION POINT AND - � f I 31 MODULES: LG LG 350N1C-V5 WARNING.INVERTER OUTPUT CONNECTIONONE DIRECTORY PLACARD i i (SAFE HARBOR MODULES:31) DO NOT RELOCATE THIS 1 BAGKFEED PANEL (� .� 31 INVERTERS:ENPHASE IQ7PLUS-72-2-US OVERCURRENT DEVICE - _ � PROJECT INFORMATION INITIAL DATE:1/28/2021 DESIGNER:SP REV: -_- DATE:-- - DESIGNER: EYDATE: DESIGNER: 1 AC-CURRENT PV _ ®® TECTILtP ® MODULES EQUIPMENT LABELS © BACKFEED Pv� RT- most advanced, Rail-less, t Self-flashing PV Mounting System �'��'4h� � �� i1 '"`'''a.� '��:3•;rte•;`~.', �_' - - _max u,._��;`,�-��^`^--"-.�'t=� �t;}; � + a""=r },�;�i�,',4 'y'a'�.',.� '�•1•..yv''s,,�,,,•, `�'-'M1�,Tpa'ier`:ir r� '"i''{.�',4`k, r' ' �{} � �S��i�i3.^�"'f�dtS�a1a'��E� wt'='�y`-tti' `��t7`��7(•��'',5 '"�°' C. `x^.a� , r RT- 'Universal Ciarnping / Slide On Mounting One, step Leveling / Integrated Flexible Flashing Proven Pi/ mounting since 1994 ICC c S MEniaen ICC ESR 3575 Intertek of Tech The S17Wj& roof Flexible Flashing Since ••. RT APEA The standard for rail-less PV mounting Installation Item & Part Number Install Base and End clamp Slide In Mounting RT-APEX Base(RT3-00-AXBK) l , RT-Apex Base;24 ea. SD5-60 Screws;48 ea. Additonal RT-Butyl; 12 ea. Middle clamp Middle Clamp(RT3-02-UM-BK) Middle Floating Splice(RT3-02-UMFSBK) Middle Clamp Splice(RT3-02-UMSBK) P Middle clamp; 12 ea. , ® End Clamp(RT3-02-UE-BK) End Floating Splice(RT3-02-UEFSBK) End Clamp Splice(RT3-02-UESBK) Skirt and End Splice Skirt and End clamp End Clamp; 12 ea. x , RT-APEX Skirt(RT3-03-SK80BL) One step leveling o L RT-Apex Skirt Winch;8 ea. 4 1/4" (108mm 3,, ) e�I _ Material Description Data sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters Regio.n AMERICAS _ _ INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US - Commonly used module pairings': 235W-350W+ 235_W-44OW+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A Enphase The high-powered smart grid-ready Overvoltage class DC port u u DC port backfeed current 0 A 0 A Enphase IQ 7 Microi and Enphase-IQ 7+Micro,, - and 6d I y y simplify PV array configuration 1 x 1 ungrounded array,No additional DC side protection required, IQ 7 ®♦ - dramaticall sim ll the Installation process while AC side protection requires max 20A per branch circuit Microinverters a achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter c r e n Y®p e rte rS Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA - IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208V/ 240 V/ 208V/ 9 P 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy-,Enphase IQ Battery'',and the Enphase Maximum continuous output current 1.0 A(240 V) 115 A(208 V) 1 21 A(240 V) 139 A(208 V) Enlighten'monitoring and analysis software Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5 8 Arms 5 8 Arms Maximum units per 20 A(L-L)branch circuity 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and overvoltage class AC-port III . . III - - - undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor setting 1 0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0 85 leading 0 85 lagging 0 85leading. 0 85 lagging warranty of up to 25 years EFFICIENCY @240 V @zoa v @240 v @zos v Peak efficiency 976% 976% 975% 973% CEC weighted efficiency 970% 970% 970% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30 2 mm(without bracket) Lightweight and simple Weight 108 kg(2 38 lbs) Faster Installation with Improved,lighter two-wire cabling Cooling Natural convection-No fans Built-In rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-Insulated,corrosion resistant polymeric enclosure Productive and Reliable Environmental category/UV exposure rating NEMA Type 6/outdoor — Optimized for high powered 60-cell and 72-cell*modules FEATURES More than a million hours of testing Communication Power Line Communication(PLC) Class II double-Insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options Both options require installation of an Enphase IQ Envoy UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break 0 disconnect required by NEC 690 Smart Grid Read Compliance CA Rule 21(UL 1741-SA) Ready UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Compiles with advanced grid support,voltage and CAN/CSA-C22 2 NO 1071-01 _ This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 69012 and C221-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions grid requirements Configurable for varying grid profiles Meets CA Rule 21(UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules 1 No enforced DC/AC ratio See the compatibility calculator at hltDs.HenDhase-com/en-us/support/module-compatibility U` 2 Nominal voltage range can be extended beyond nominal if required by the utility 3 Limits may vary Refer to local requirements to define the number of microinverters per branch in your area ® E P H A S E. To learn more about Enphase offerings,visit enphase.com E N P H AS E. To learn more about Enphase offerings,VISIt enphase.COm 9)2019 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc _ 2019-3-26 - - - - - LG NeONO2 LG345N1C-V5- LG35ON1C-VS - _ General Data Electrical Properties(STC*) LG345N1C-V5 { LG350N1C-V5 cell Propemes(MateriaVrype) Monacrystalline/N-type Model LG345N1C-VS LG350N1C-V5 Cell Maker LG Mawmum Power(Pmax) [W] 345 350 Cell Configuration 60 Cells(6 x 10) MPP Voltage(vmpp) [V] 349 253 [/j Numberof Busbars 12EA MPP current Qmpp) [A] 989 992 3 S W I SOW Module Dimensions(Lx W x H) 1,686mm x 1,016mm x 40 mm Open Cvcwt Voltage CVKt 5%) [V] 41 2 413 Weight 171 kg Short Grant Cuvent(lsc,tS%) [A] 1057 1061 Glass(Material) - Tempered Glass with AR Coating - Module Effiaency [%] 201 204 The LG NeON°2 Is LG's best selling solar module,and Is one of the mo _ Backsheet(Color) - White Power Tolerance [%] 0-.3 powerful and versatile modules on the market today Featuring LG's Ce Frame(Material) __ Anod¢ed Aluminum__- 'STC(SandardTest condmon)Imamance 1000 Wim',cell tempemwm 25°C,AM 15 Junction Box(Protemon Degree) IP 68 with 3 Bypass Diodes "Measuremenc7oleance'_3% Technology,the LG NeON°2 Increases power output New updates Inc Cannes(Length) 1,000 an extended performance warranty to 90 08%to give customers high( performance and reliability eannettnr(rype/Make) Me4/MC/MC Operating Conditions I Certifications and Warranty Operating Temperature [°C] -40-+90 DVE ( U� pg m�x I IEC 61215-1/-1-1/22016,IEC 61730-1/22016, Maximum System Voltage [V] 1,000 VV UL 1703 Mawmum Series Fuse Raring [A] 20 Certifications ISO 9001,ISO 14001,ISO 50001 Methan¢alTest Load(From) [Pa/psf] 5,400/113 OHSA518001 Merharncanrestlaed(Rear) r-,- 4,000/835 ® Salt Mist ComostonTist IEC617012012Seventy6 'Medi ,cal Tea Loads,400Pa/4,000PabasedonlEC61215-2 2016 - ] Ammonia CormsionT t IEC 627162013 T ti-oad-Design Load,SafetyFaaor(15) Module Fire Performance Type 1(UL 1703) Fire Rating Class C(UL79Q ULCIORD C 1703) Solar Module Produa Warranty 25 rears Packaging Configuration Solar Module 0utputWarranty LmearWarranty• Numberof Modules per Pallet [EA] 25 'Improved l scyear 98%from 2-24[h year 033%/y ear down after 25th year 9008% Number of Modules per 40ft HQ container _ [EA] 650 Packaging Box Dimensions(L x W x H) [mm] 1,750 x 1,120 x 1,221 Temperature Characteristics Packaging Box Gross Weight [kg] 464 _ NMOT• [°C] 42 t 3 Pmax WC] -036 a Voc [Yrc] -026 isc [%/°c] 003 Dimensions(mm/Inch) 'NMOr(Nomml Module Operating T pmwm)Iriadianre 800 W/m',Ambient temperature 20°C, Wind speed 1 m/s,Spectrum AM 15 Features _ ElectncalProernes NMO (1vtnviAndi Model LG345N1C-VS LG350N1C-VS oo.di,aw — --"") Enhanced Performance Warranty } Enhanced Product Warranty M—.u.Power(Pmax) [w] 259 262 j I ] 25yn I MPPVohage(VmPp) [V] 328 332 LG NeON°2 has an enhanced LG has extended the warranty of the MPPCurrent(Impp) [A] 789 791 performance warranty After 25 NeON°2 to 25 years Including labor, Open Cncmt Voltage(Voc) [V] 38.8 389 years,LG NeON°2 Is guaranteed at 3 which Is top level In the Industry ShortOncutCument(Isc) [A] 8,49 8.52 least 90.08%of Initial performance. I-V Curves •�m 120 m g ®1 laOaW yl d 2° Better Performance on a Sunny Day ! 4 Roof Aesthetics 100 g{ j LG NeON°2 now performs better on I j ®J LG NeON°2 has been designed with z 80 sunny days,thanks to Its Improved ___._. aesthetics In mind using thinner wires 60 ooav temperature coefficient that appear all black at a distance The LG jNeON°2 can increase the aesthetic value 40 4 of your home with a more modern design 20 [ 2-v ora ° a ---------------------------- - -- ------------------- -------------------- - ------------- ------------ ao 100 zoo 300 400 ° 8 When you go solar,ask for the brand you can trust: LG Solar Voltage(V) About LG Electronics LG Electtom s a global leader n electronic pr°ducts m the clean energy markets b ffenn lar PV Is and enc storage systems.The company first embarked on a solar LG Electronics Inc Product specifications are subject to change without nonce //�� Solar BusinessD neon by gso pane energy g sys y LG LG345-350N1C-VS pdf ° _ - energy source research program m 1985,supported by LG Groups vast experience in the semi-conductor,LCD chemistryand materials industnes.In 2010 LG Solar successfully LG S®I a r - 2000 h-,I k Drive _ - _ released its first MonoXs series to the market which cs now available m 32 countries The NeONs(pievious IVI—Xi"NeON)NeON®2 N,ON62 BiFaaal won the'Intersolar `- Lincolnshire,IL 60069 _ AWARD'm 2013,2015 and 2016,which demonstrates LG's leadershipandmnwabomn Me sol-rdustry, - LIfes GOOd wwwIg-solarccm 02019 LG Electromts.All rights reserved